Sample records for chromogenic substrate method

  1. In Vitro Screening of Synthetic Fluorogenic Substrates for Detection of Cancer Procoagulant Activity.

    PubMed

    Krause, Jason; Frost, Carminita L

    2018-04-01

    Cancer procoagulant (CP), a direct activator of coagulation factor X, is among one of the tumour cell products or activities which may promote fibrin formation and has been suggested to be selectively associated with the malignant phenotype. At present, the most reliable assay for the quantification of CP activity is the three-stage chromogenic assay which utilises the ability of CP to activate factor X. In this assay, the activation of factor X leads to the formation of activated thrombin from prothrombin and the eventual hydrolyses of a thrombin chromogenic substrate which contains a p-nitroaniline leaving group. The complexity of the three-stage chromogenic assay suggests a need for a direct method of assaying CP activity. This study focuses on the design of a fluorogenic substrate that would enable the direct quantification of CP activity. The results of the study show two promising substrates for the determination of CP activity: Boc-PQVR-AMC and PQVR-AMC. Further analysis showed that Boc-PQVR-AMC could be excluded as a potential substrate for CP since it was also cleaved by collagenase.

  2. Biological activity analysis of native and recombinant streptokinase using clot lysis and chromogenic substrate assay.

    PubMed

    Mahboubi, Arash; Sadjady, Seyyed Kazem; Mirzaei Saleh Abadi, Mohammad; Azadi, Saeed; Solaimanian, Roya

    2012-01-01

    DETERMINATION OF STREPTOKINASE ACTIVITY IS USUALLY ACCOMPLISHED THROUGH TWO ASSAY METHODS: a) Clot lysis, b) Chromogenic substrate assay. In this study the biological activity of two streptokinase products, namely Streptase®, which is a native product and Heberkinasa®, which is a recombinant product, was determined against the third international reference standard using the two forementioned assay methods. The results indicated that whilst the activity of Streptase® was found to be 101 ± 4% and 97 ± 5% of the label claim with Clot lysis and Chromogenic substrate assay respectively, for Heberkinasa® the potency values obtained were 42 ± 5% and 92.5 ± 2% of the label claim respectively. To shed some light on the reason for this finding, the n-terminal sequence of the streptokinase molecules present in the two products was determined. The results showed slight differences in the amino acid sequence of the recombinant product in comparison to the native one at the amino terminus. This finding supports those of other workers who found that n-terminal sequence of the streptokinase molecule can have significant effect on the activity of this protein.

  3. Substrates and method for determining enzymes

    DOEpatents

    Smith, Robert E.; Bissell, Eugene R.

    1981-01-01

    A method is disclosed for determining the presence of an enzyme in a biological fluid, which includes the steps of contacting the fluid with a synthetic chromogenic substrate, which is an amino acid derivative of 7-amino-4-trifluoromethylcoumarin; incubating the substrate-containing fluid to effect enzymatic hydrolysis; and fluorometrically determining the presence of the free 7-amino-4-trifluoromethylcoumarin chromophore in the hydrolyzate.

  4. Substrates and method for determining enzymes

    DOEpatents

    Smith, R.E.; Bissell, E.R.

    1981-10-13

    A method is disclosed for determining the presence of an enzyme in a biological fluid, which includes the steps of contacting the fluid with a synthetic chromogenic substrate, which is an amino acid derivative of 7-amino-4-trifluoromethylcoumarin; incubating the substrate-containing fluid to effect enzymatic hydrolysis; and fluorometrically determining the presence of the free 7-amino-4-trifluoromethylcoumarin chromophore in the hydrolyzate. No Drawings

  5. Synthesis and evaluation of chromogenic and fluorogenic substrates for high-throughput detection of enzymes that hydrolyze inorganic polyphosphate.

    PubMed

    Hebbard, Carleigh F F; Wang, Yan; Baker, Catherine J; Morrissey, James H

    2014-08-11

    Inorganic polyphosphates, linear polymers of orthophosphate, occur naturally throughout biology and have many industrial applications. Their biodegradable nature makes them attractive for a multitude of uses, and it would be important to understand how polyphosphates are turned over enzymatically. Studies of inorganic polyphosphatases are, however, hampered by the lack of high-throughput methods for detecting and quantifying rates of polyphosphate degradation. We now report chromogenic and fluorogenic polyphosphate substrates that permit spectrophotometric monitoring of polyphosphate hydrolysis and allow for high-throughput analyses of both endopolyphosphatase and exopolyphosphatase activities, depending on assay configuration. These substrates contain 4-nitrophenol or 4-methylumbelliferone moieties that are covalently attached to the terminal phosphates of polyphosphate via phosphoester linkages formed during reactions mediated by EDAC (1-ethyl-3-(3-(dimethylamino)propyl)carbodiimide). This report identifies Nudt2 as an inorganic polyphosphatase and also adds to the known coupling chemistry for polyphosphates, permitting facile covalent linkage of alcohols with the terminal phosphates of inorganic polyphosphate.

  6. Chromogenic assay for BAY 81-8973 potency assignment has no impact on clinical outcome or monitoring in patient samples.

    PubMed

    Kitchen, S; Katterle, Y; Beckmann, H; Maas Enriquez, M

    2016-06-01

    Essentials Discrepancies can exist in factor VIII activity measured by the one-stage or chromogenic assays. LEOPOLD trial data were used to assess clinical impact of BAY 81-8973 potency assignment assay. Efficacy was not affected by the assay used for potency assignment and dosing of BAY 81-8973. Either assay may be used to measure factor VIII activity after BAY 81-8973 infusion. Background Product-specific discrepancies have been reported for factor VIII (FVIII) activity determined with one-stage or chromogenic assays. Objective To assess the clinical impact of potency assignment of BAY 81-8973, a full-length, unmodified, recombinant human FVIII, by use of the chromogenic assay or chromogenic assay adjusted to mimic results obtained with the one-stage assay Patients/methods Patients aged 12-65 years with severe hemophilia A received BAY 81-8973 in LEOPOLD I (20-50 IU kg(-1) two or three times weekly [investigator decision]) and LEOPOLD II (randomized to 20-30 IU kg(-1) twice weekly, 30-40 IU kg(-1) three times weekly, or on-demand treatment). Both trials included two 6-month crossover periods in which potency labeling was determined with the chromogenic substrate assay as per the European Pharmacopoeia (CS/EP) or the chromogenic substrate assay adjusted to mimic results obtained with the one-stage assay (CS/ADJ). The annualized bleeding rate (ABR) and FVIII incremental recovery were assessed by the use of pooled data. Results The analysis was perfomed on 121 patients. Median (quartile [Q] 1; Q3) ABRs during the CS/EP and CS/ADJ periods were 1.98 (0; 5.92) and 1.98 (0; 7.34), respectively. The mean incremental recovery was > 2 IU dL(-1) per IU kg(-1) in both periods with the use of either assay for postinfusion FVIII measurements. The median (Q1; Q3) chromogenic/one-stage assay recovery ratio was 1.054 (0.892; 1.150) for the CS/EP period when a plasma standard was used for calibration. Conclusions No impact on the ABR was observed with chromogenic-based as compared with one-stage assay-based potency and dosing. Either assay may be used to determine FVIII plasma activity after infusion of BAY 81-8973 without the need for a product-specific standard. © 2016 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis.

  7. Method for filling the cavities of cells with a chromogenic fluid

    DOEpatents

    Tonazzi, J.C.L.; Kucharczyk, J.E. Jr.; Agrawal, A.

    1999-01-05

    A method and apparatus are disclosed for filling a cell cavity positioned between a first substrate and a second substrate with a cell filling liquid. The method entails forming at least one evacuation cavity encompassing at least a portion of an outer surface of each of the first and second substrates of a cell containing a cell cavity and isolating the cell cavity from the evacuation cavity; reducing a pressure in each of the evacuation cavity and the cell cavity; and dispensing the cell filling fluid into the cell cavity. The application is to the fabrication of electrochromic windows. 22 figs.

  8. Development of a Novel Screening Method for the Isolation of “Cronobacter” spp. (Enterobacter sakazakii)▿

    PubMed Central

    Iversen, Carol; Druggan, Patrick; Schumacher, Sandra; Lehner, Angelika; Feer, Claudia; Gschwend, Karl; Joosten, Han; Stephan, Roger

    2008-01-01

    A differential medium, “Cronobacter” screening broth, has been designed to complement agars based on hydrolysis of chromogenic α-glucopyranoside substrates. The broth was evaluated using 329 Enterobacteriaceae strains (229 target isolates), spiked/naturally contaminated samples, and a parallel comparison with current methods for raw materials, line/end products, and factory environment samples. PMID:18310415

  9. An allosteric disulfide bond is involved in enhanced activation of factor XI by protein disulfide isomerase.

    PubMed

    Zucker, M; Seligsohn, U; Yeheskel, A; Mor-Cohen, R

    2016-11-01

    Essentials Reduction of three disulfide bonds in factor (F) XI enhances chromogenic substrate cleavage. We measured FXI activity upon reduction and identified a bond involved in the enhanced activity. Reduction of FXI augments FIX cleavage, probably by faster conversion of FXI to FXIa. The Cys362-Cys482 disulfide bond is responsible for FXI enhanced activation upon its reduction. Background Reduction of factor (F) XI by protein disulfide isomerase (PDI) has been shown to enhance the ability of FXI to cleave its chromogenic substrate. Three disulfide bonds in FXI (Cys118-Cys147, Cys362-Cys482, and Cys321-Cys321) are involved in this augmented activation. Objectives To characterize the mechanisms by which PDI enhances FXI activity. Methods FXI activity was measured following PDI reduction. Thiols that were exposed in FXI after PDI reduction were labeled with 3-(N-maleimidopropionyl)-biocytin (MPB) and detected with avidin. The rate of conversion of FXI to activated FXI (FXIa) following thrombin activation was assessed with western blotting. FXI molecules harboring mutations that disrupt the three disulfide bonds (C147S, C321S, and C482S) were expressed in cells. The antigenicity of secreted FXI was measured with ELISA, and its activity was assessed by the use of a chromogenic substrate. The effect of disulfide bond reduction was analyzed by the use of molecular dynamics. Results Reduction of FXI by PDI enhanced cleavage of both its chromogenic substrate, S2366, and its physiologic substrate, FIX, and resulted in opening of the Cys362-Cys482 bond. The rate of conversion of FXI to FXIa was increased following its reduction by PDI. C482S-FXI showed enhanced activity as compared with both wild-type FXI and C321S-FXI. MD showed that disruption of the Cys362-Cys482 bond leads to a broader thrombin-binding site in FXI. Conclusions Reduction of FXI by PDI enhances its ability to cleave FIX, probably by causing faster conversion of FXI to FXIa. The Cys362-Cys482 disulfide bond is involved in enhancing FXI activation following its reduction, possibly by increasing thrombin accessibility to FXI. © 2016 International Society on Thrombosis and Haemostasis.

  10. Heat pretreatment eliminates spurious butyrylcholinesterase enhancement of endotoxin levels in the kinetic chromogenic assay.

    PubMed

    Brawner, Andrew; Hinrichs, Steven H; Larson, Marilynn A; Lockridge, Oksana

    2016-04-05

    The kinetic chromogenic endotoxin assay measures the release of p-nitroaniline from the chromogenic peptide substrate Ac-IEAR-pNA. As part of our project to purify large quantities of human butyrylcholinesterase (HuBChE), we evaluated pure HuBChE for endotoxin levels. We found that HuBChE contributed up to 90% of the yellow p-nitroaniline product in a standard endotoxin assay through the catalytic hydrolysis of Ac-IEAR-pNA with a rate constant of 0.016 min(-1) and a Km of 2.9 mM in potassium phosphate buffer pH 7.0 at 24 °C. Thus, endotoxin concentrations for native BChE are artificially high in the kinetic chromogenic assay. Destruction of HuBChE catalytic activity by boiling yields endotoxin concentrations that more accurately reflect the endotoxin concentration in purified HuBChE preparations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Feasibility of Monitoring Pesticide Breakthrough from Charcoal Columns

    DTIC Science & Technology

    1979-09-01

    the rapid detection of these compounds in water at proposed Army pesti- cide filtration plants . Sensitivities to the phosphorothionates diazinon...a large number of pesticid&. filtration plants . !• All the standard chemical methods described in the retrieved ar- ticles were based on some property...impregnated with a chromogenic substrate and a developing spray containing active cholinesterase.6_-! Pesticides are visualized as white spots on a colored

  12. Nonpeptide-Based Small-Molecule Probe for Fluorogenic and Chromogenic Detection of Chymotrypsin.

    PubMed

    Wu, Lei; Yang, Shu-Hou; Xiong, Hao; Yang, Jia-Qian; Guo, Jun; Yang, Wen-Chao; Yang, Guang-Fu

    2017-03-21

    We report herein a nonpeptide-based small-molecule probe for fluorogenic and chromogenic detection of chymotrypsin, as well as the primary application for this probe. This probe was rationally designed by mimicking the peptide substrate and optimized by adjusting the recognition group. The refined probe 2 exhibits good specificity toward chymotrypsin, producing about 25-fold higher enhancement in both the fluorescence intensity and absorbance upon the catalysis by chymotrypsin. Compared with the most widely used peptide substrate (AMC-FPAA-Suc) of chymotrypsin, probe 2 shows about 5-fold higher binding affinity and comparable catalytical efficiency against chymotrypsin. Furthermore, it was successfully applied for the inhibitor characterization. To the best of our knowledge, probe 2 is the first nonpeptide-based small-molecule probe for chymotrypsin, with the advantages of simple structure and high sensitivity compared to the widely used peptide-based substrates. This small-molecule probe is expected to be a useful molecular tool for drug discovery and chymotrypsin-related disease diagnosis.

  13. Simultaneous Identification and Antimicrobial Susceptibility Testing of Multiple Uropathogens on a Microfluidic Chip with Paper-Supported Cell Culture Arrays.

    PubMed

    Xu, Banglao; Du, Yan; Lin, Jinqiong; Qi, Mingyue; Shu, Bowen; Wen, Xiaoxia; Liang, Guangtie; Chen, Bin; Liu, Dayu

    2016-12-06

    A microfluidic chip was developed for one-step identification and antimicrobial susceptibility testing (AST) of multiple uropathogens. The polydimethylsiloxane (PDMS) microchip used had features of cell culture chamber arrays connected through a sample introduction channel. At the bottom of each chamber, a paper substrate preloaded with chromogenic media and antimicrobial agents was embedded. By integrating a hydrophobic membrane valve on the microchip, the urine sample can be equally distributed into and confined in individual chambers. The identification and AST assays on multiple uropathogens were performed by combining the spatial resolution of the cell culture arrays and the color resolution from the chromogenic reaction. The composite microbial testing assay was based on dynamic changes in color in a serial of chambers. The bacterial antimicrobial susceptibility was determined by the lowest concentration of an antimicrobial agent that is capable of inhibiting the chromogenic reaction. Using three common uropathogenic bacteria as test models, the developed microfluidic approach was demonstrated to be able to complete the multiple colorimetric assays in 15 h. The accuracy of the microchip method, in comparison with that of the conventional approach, showed a coincidence of 94.1%. Our data suggest this microfluidic approach will be a promising tool for simple and fast uropathogen testing in resource-limited settings.

  14. Enzyme Kinetics: The Use of Amylose Azure.

    ERIC Educational Resources Information Center

    Cusimano, Vincent J.

    1978-01-01

    Amylose azure can be used as a chromogenic substrate for alpha-amylase in studying the effects of temperature and pH enzyme action. This is a model system which students can use to measure the energy of activation using the Arrhenius plot. (Author/BB)

  15. Spore immobilization and its analytical performance for monitoring of aflatoxin M1 in milk.

    PubMed

    Singh, V K; Singh, N A; Kumar, N; Raghu, H V; Sharma, Pradeep Kumar; Singh, K P; Yadav, Avinash

    2014-12-01

    Immobilization of Bacillus megaterium spores on Eppendorf tubes through physical adsorption has been used in the detection of aflatoxin M1 (AFM1) in milk within real time of 45 ± 5 min using visual observation of changes in a chromogenic substrate. The appearance of a sky-blue colour indicates the absence of AFM1 in milk, whereas no colour change indicates the presence of AFM1 in milk at a 0.5 ppb Codex maximum residue limit. The working performance of the immobilized spores was shown to persist for up to 6 months. Further, spores immobilized on 96-well black microtitre plates by physical adsorption and by entrapment on sensor disk showed a reduction in detection sensitivity to 0.25 ppb within a time period of 20 ± 5 min by measuring fluorescence using a microbiological plate reader through the addition of milk and fluorogenic substrate. A high fluorescence ratio indicated more substrate hydrolysis due to spore-germination-mediated release of marker enzymes of spores in the absence of AFM1 in milk; however, low fluorescence ratios indicated the presence of AFM1 at 0.25 ppb. Immobilized spores on 96-well microtitre plates and sensor disks have shown better reproducibility after storage at 4 °C for 6 months. Chromogenic assay showed 1.38% false-negative and 2.77% false-positive results while fluorogenic assay showed 4.16% false-positive and 2.77% false-negative results when analysed for AFM1 using 72 milk samples containing raw, pasteurized, and dried milk. Immobilization of spores makes these chromogenic and fluorogenic assays portable, selective, cost-effective for real-time detection of AFM1 in milk at the dairy farm, reception dock, and manufacturing units of the dairy industry.

  16. Quantitative digital image analysis of chromogenic assays for high throughput screening of alpha-amylase mutant libraries.

    PubMed

    Shankar, Manoharan; Priyadharshini, Ramachandran; Gunasekaran, Paramasamy

    2009-08-01

    An image analysis-based method for high throughput screening of an alpha-amylase mutant library using chromogenic assays was developed. Assays were performed in microplates and high resolution images of the assay plates were read using the Virtual Microplate Reader (VMR) script to quantify the concentration of the chromogen. This method is fast and sensitive in quantifying 0.025-0.3 mg starch/ml as well as 0.05-0.75 mg glucose/ml. It was also an effective screening method for improved alpha-amylase activity with a coefficient of variance of 18%.

  17. A screen for over-secretion of proteins by yeast based on a dual component cellular phosphatase and immuno-chromogenic stain for exported bacterial alkaline phosphatase reporter

    PubMed Central

    2013-01-01

    Background To isolate over-secretors, we subjected to saturation mutagenesis, a strain of P.pastoris exporting E. coli alkaline phosphatase (EAP) fused to the secretory domain of the yeast α factor pheromone through cellular PHO1/KEX2 secretory processing signals as the α-sec-EAP reporter protein. Direct chromogenic staining for α-sec-EAP activity is non-specific as its NBT/BCIP substrate cross-reacts with cellular phosphatases which can be inhibited with Levulinic acid. However, the parental E(P) strain only exports detectable levels of α-sec-EAP at 69 hours and not within the 36 hour period post-seeding required for effective screening with the consequent absence of a reference for secretion. We substituted the endogenous cellular phosphatase activity as a comparative reference for secretion rate and levels as well as for colony alignment while elevating specificity and sensitivity of detection of the exported protein with other innovative modifications of the immuno-chromogenic staining application for screening protein export mutants. Results Raising the specificity and utility of staining for α-sec-EAP activity required 5 modifications including some to published methods. These included, exploitation of endogenous phosphatase activity, reduction of the cell/protein burden, establishment of the direct relation between concentrations of transcriptional inducer and exported membrane immobilized protein and concentrations of protein exported into growth media, amplification of immuno-specificity and sensitivity of detection of α-sec-EAP reporter enzyme signal and restriction of staining to optimal concentrations of antisera and time periods. The resultant immuno-chromogenic screen allows for the detection of early secretion and as little as 1.3 fold over-secretion of α-sec-EAP reporter protein by E(M) mutants in the presence of 10 fold -216 fold higher concentrations of HSA. Conclusions The modified immuno-chromogenic screen is sensitive, specific and has led to the isolation of mutants E(M) over-secreting the α-sec-EAP reporter protein by a minimum of 50 fold higher levels than that exported by non-mutagenized E(P) parental strains. Unselected proteins were also over-secreted. PMID:23602005

  18. Comparison of Chromogenic Selective Media for the Detection of Cronobacter spp. (Enterobacter sakazakii).

    PubMed

    Teramura, Hajime; Fukuda, Noriko; Okada, Yumiko; Ogihara, Hirokazu

    2018-01-01

     The four types of chromogenic selective media that are commercially available in Japan were compared for establishing a Japanese standard method for detecting Cronobacter spp. based on ISO/TS 22964:2006. When assessed using 9 standard Cronobacter spp. strains and 29 non-Cronobacter strains, Enterobacter sakazakii isolation agar, Chromocult TM Enterobacter sakazakii agar, CHROMagar TM E. sakazakii, and XM-sakazakii agar demonstrated excellent inclusivity and exclusivity. Using the ISO/TS 22964:2006 method, the recovered numbers of 38 Cronobacter spp. strains, including 29 C. sakazakii isolates obtained from each medium, were equivalent, indicating that there was no significant difference (p > 0.05) among the four types of chromogenic selective media. Thus, we demonstrated that these four chromogenic selective media are suitable alternatives when using the standard method for detecting Cronobacter spp. in Japan, based on the ISO/TS 22964:2006.

  19. Molecular-level insights into intrinsic peroxidase-like activity of nanocarbon oxides.

    PubMed

    Zhao, Ruisheng; Zhao, Xiang; Gao, Xingfa

    2015-01-12

    Nanocarbon oxides have been proved to possess great peroxidase-like activity, catalyzing the oxidation of many peroxidase substrates, such as 3,3',5,5'-tetramethylbenzidine (TMB) and o-phenylenediamine dihydrochloride (OPD), accompanied by a significant color change. This chromogenic reaction is widely used to detect glucose and occult blood. The chromogenic reaction was intensively investigated with density functional theory and molecular-level insights into the nature of peroxidase-like activity were gained. A radical mechanism was unraveled and the carboxyl groups of nanocarbon oxides were identified as the reactive sites. Aromatic domains connected with the carboxyl groups were critical to the peroxidase-like activity. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Development of a More Sensitive and Specific Chromogenic Agar Medium for the Detection of Vibrio parahaemolyticus and Other Vibrio Species.

    PubMed

    Yeung, Marie; Thorsen, Trevor

    2016-11-08

    Foodborne infections in the US caused by Vibrio species have shown an upward trend. In the genus Vibrio, V. parahaemolyticus is responsible for the majority of Vibrio-associated infections. Thus, accurate differentiation among Vibrio spp. and detection of V. parahaemolyticus is critically important to ensure the safety of our food supply. Although molecular techniques are increasingly common, culture-depending methods are still routinely done and they are considered standard methods in certain circumstances. Hence, a novel chromogenic agar medium was tested with the goal of providing a better method for isolation and differentiation of clinically relevant Vibrio spp. The protocol compared the sensitivity, specificity and detection limit for the detection of V. parahaemolyticus between the new chromogenic medium and a conventional medium. Various V. parahaemolyticus strains (n=22) representing diverse serotypes and source of origins were used. They were previously identified by Food and Drug Administration (FDA) and Centers for Disease Control and Prevention (CDC), and further verified in our laboratory by tlh-PCR. In at least four separate trials, these strains were inoculated on the chromogenic agar and thiosulfate-citrate-bile salts-sucrose (TCBS) agar, which is the recommended medium for culturing this species, followed by incubation at 35-37 °C for 24-96 hr. Three V. parahaemolyticus strains (13.6%) did not grow optimally on TCBS, nonetheless exhibited green colonies if there was growth. Two strains (9.1%) did not yield the expected cyan colonies on the chromogenic agar. Non-V. parahaemolyticus strains (n=32) were also tested to determine the specificity of the chromogenic agar. Among these strains, 31 did not grow or exhibited other colony morphologies. The mean recovery of V. parahaemolyticus on the chromogenic agar was ~96.4% relative to tryptic soy agar supplemented with 2% NaCl. In conclusion, the new chromogenic agar is an effective medium to detect V. parahaemolyticus and to differentiate it from other vibrios.

  1. Application of Photoshop and Scion Image analysis to quantification of signals in histochemistry, immunocytochemistry and hybridocytochemistry.

    PubMed

    Tolivia, Jorge; Navarro, Ana; del Valle, Eva; Perez, Cristina; Ordoñez, Cristina; Martínez, Eva

    2006-02-01

    To describe a simple method to achieve the differential selection and subsequent quantification of the strength signal using only one section. Several methods for performing quantitative histochemistry, immunocytochemistry or hybridocytochemistry, without use of specific commercial image analysis systems, rely on pixel-counting algorithms, which do not provide information on the amount of chromogen present in the section. Other techniques use complex algorithms to calculate the cumulative signal strength using two consecutive sections. To separate the chromogen signal we used the "Color range" option of the Adobe Photoshop program, which provides a specific file for a particular chromogen selection that could be applied on similar sections. The measurement of the chromogen signal strength of the specific staining is achieved with the Scion Image software program. The method described in this paper can also be applied to simultaneous detection of different signals on the same section or different parameters (area of particles, number of particles, etc.) when the "Analyze particles" tool of the Scion program is used.

  2. Multi-wavelength dye concentration determination for enzymatic assays: evaluation of chromogenic para-nitrophenol over a wide pH range.

    PubMed

    Max, Jean-Joseph; Meddeb-Mouelhi, Fatma; Beauregard, Marc; Chapados, Camille

    2012-12-01

    Enzymatic assays need robust, rapid colorimetric methods that can follow ongoing reactions. For this, we developed a highly accurate, multi-wavelength detection method that could be used for several systems. Here, it was applied to the detection of para-nitrophenol (pNP) in basic and acidic solutions. First, we confirmed by factor analysis that pNP has two forms, with unique spectral characteristics in the 240 to 600 nm range: Phenol in acidic conditions absorbs in the lower range, whereas phenolate in basic conditions absorbs in the higher range. Thereafter, the method was used for the determination of species concentration. For this, the intensity measurements were made at only two wavelengths with a microtiter plate reader. This yielded total dye concentration, species relative abundance, and solution pH value. The method was applied to an enzymatic assay. For this, a chromogenic substrate that generates pNP after hydrolysis catalyzed by a lipase from the fungus Yarrowia lipolytica was used. Over the pH range of 3-11, accurate amounts of acidic and basic pNP were determined at 340 and 405 nm, respectively. This method surpasses the commonly used single-wavelength assay at 405 nm, which does not detect pNP acidic species, leading to activity underestimations. Moreover, alleviation of this pH-related problem by neutralization is not necessary. On the whole, the method developed is readily applicable to rapid high-throughput of enzymatic activity measurements over a wide pH range.

  3. MicroRNA Detection by Whole-Mount In Situ Hybridization in C. elegans.

    PubMed

    Andachi, Yoshiki; Kohara, Yuji

    2018-01-01

    MicroRNAs (miRNAs) loaded on argonaute proteins guide RNA-induced silencing complexes to target mRNAs. An excellent method to decipher the spatiotemporal expression patterns of miRNAs is whole-mount in situ hybridization (WISH), which has been successfully used in vertebrate embryos but still remains unavailable for many animal species. Here, we describe a WISH method for miRNA detection in Caenorhabditis elegans at both embryonic and post-embryonic stages. Strategies devised for detection include fixation of animals with carbodiimide at a high temperature and subsequent partial digestion of the fixed animals with an extremely high concentration of proteinase. WISH signals are visualized by staining with a chromogenic substrate or a fluorescent dye.

  4. Sensitive colorimetric assay for uric acid and glucose detection based on multilayer-modified paper with smartphone as signal readout.

    PubMed

    Wang, Xu; Li, Fang; Cai, Ziqi; Liu, Kaifan; Li, Jing; Zhang, Boyang; He, Jianbo

    2018-04-01

    In this work, a multilayer-modified paper-based colorimetric sensing platform with improved color uniformity and intensity was developed for the sensitive and selective determination of uric acid and glucose with smartphone as signal readout. In detail, chitosan, different kinds of chromogenic reagents, and horseradish peroxidase (HRP) combined with a specific oxidase, e.g., uricase or glucose oxidase (GOD), were immoblized onto the paper substrate to form a multilayer-modified test paper. Hydrogen peroxide produced by the oxidases (uricase or GOD) reacts with the substrates (uric acid or glucose), and could oxidize the co-immoblized chromogenic reagents to form colored products with HRP as catalyst. A simple strategy by placing the test paper on top of a light-emitting diode lamp was adopted to efficiently prevent influence from the external light. The color images were recorded by the smartphone camera, and then the gray values of the color images were calculated for quantitative analysis. The developed method provided a wide linear response from 0.01 to 1.0 mM for uric acid detection and from 0.02 to 4.0 mM for glucose detection, with a limit of detection (LOD) as low as 0.003 and 0.014 mM, respectively, which was much lower than for previously reported paper-based colorimetric assays. The proposed assays were successfully applied to uric acid and glucose detection in real serum samples. Furthermore, the enhanced analytical performance of the proposed method allowed the non-invasive detection of glucose levels in tear samples, which holds great potential for point-of-care analysis. Graphical abstract ᅟ.

  5. Comparison of the quantitative dry culture methods with both conventional media and most probable number method for the enumeration of coliforms and Escherichia coli/coliforms in food.

    PubMed

    Teramura, H; Sota, K; Iwasaki, M; Ogihara, H

    2017-07-01

    Sanita-kun™ CC (coliform count) and EC (Escherichia coli/coliform count), sheet quantitative culture systems which can avoid chromogenic interference by lactase in food, were evaluated in comparison with conventional methods for these bacteria. Based on the results of inclusivity and exclusivity studies using 77 micro-organisms, sensitivity and specificity of both Sanita-kun™ met the criteria for ISO 16140. Both media were compared with deoxycholate agar, violet red bile agar, Merck Chromocult™ coliform agar (CCA), 3M Petrifilm™ CC and EC (PEC) and 3-tube MPN, as reference methods, in 100 naturally contaminated food samples. The correlation coefficients of both Sanita-kun™ for coliform detection were more than 0·95 for all comparisons. For E. coli detection, Sanita-kun™ EC was compared with CCA, PEC and MPN in 100 artificially contaminated food samples. The correlation coefficients for E. coli detection of Sanita-kun™ EC were more than 0·95 for all comparisons. There were no significant differences in all comparisons when conducting a one-way analysis of variance (anova). Both Sanita-kun™ significantly inhibited colour interference by lactase when inhibition of enzymatic staining was assessed using 40 natural cheese samples spiked with coliform. Our results demonstrated Sanita-kun™ CC and EC are suitable alternatives for the enumeration of coliforms and E. coli/coliforms, respectively, in a variety of foods, and specifically in fermented foods. Current chromogenic media for coliforms and Escherichia coli/coliforms have enzymatic coloration due to breaking down of chromogenic substrates by food lactase. The novel sheet culture media which have film layer to avoid coloration by food lactase have been developed for enumeration of coliforms and E. coli/coliforms respectively. In this study, we demonstrated these media had comparable performance with reference methods and less interference by food lactase. These media have a possibility not only to be useful alternatives but also to contribute for accurate enumeration of these bacteria in a variety of foods, and specifically in fermented foods. © 2017 The Society for Applied Microbiology.

  6. A novel clot lysis assay for recombinant plasminogen activator.

    PubMed

    Jamialahmadi, Oveis; Fazeli, Ahmad; Hashemi-Najafabadi, Sameereh; Fazeli, Mohammad Reza

    2015-03-01

    Recombinant plasminogen activator (r-PA, reteplase) is an engineered variant of alteplase. When expressed in E. coli, it appears as inclusion bodies that require refolding to recover its biological activity. An important step following refolding is to determine the activity of refolded protein. Current methods for enzymatic activity of thrombolytic drugs are costly and complex. Here a straightforward and low-cost clot lysis assay was developed. It quantitatively measures the activity of the commercial reteplase and is also capable of screening refolding conditions. As evidence for adequate accuracy and sensitivity of the current assay, r-PA activity measurements are shown to be comparable to those obtained from chromogenic substrate assay.

  7. A new method for monitoring the extracellular proteolytic activity of wine yeasts during alcoholic fermentation of grape must.

    PubMed

    Chasseriaud, Laura; Miot-Sertier, Cécile; Coulon, Joana; Iturmendi, Nerea; Moine, Virginie; Albertin, Warren; Bely, Marina

    2015-12-01

    The existing methods for testing proteolytic activity are time consuming, quite difficult to perform, and do not allow real-time monitoring. Proteases have attracted considerable interest in winemaking and some yeast species naturally present in grape must, such as Metschnikowia pulcherrima, are capable of expressing this activity. In this study, a new test is proposed for measuring proteolytic activity directly in fermenting grape must, using azocasein, a chromogenic substrate. Several yeast strains were tested and differences in proteolytic activity were observed. Moreover, analysis of grape must proteins in wines revealed that protease secreted by Metschnikowia strains may be active against wine proteins. Copyright © 2015. Published by Elsevier B.V.

  8. New Chromogenic Agar Medium for the Identification of Candida spp.

    PubMed Central

    Cooke, Venitia M.; Miles, R. J.; Price, R. G.; Midgley, G.; Khamri, W.; Richardson, A. C.

    2002-01-01

    A new chromogenic agar medium (Candida diagnostic agar [CDA]) for differentiation of Candida spp. is described. This medium is based on Sabouraud dextrose agar (Oxoid CM41) and contains (per liter) 40.0 g of glucose, 10.0 g of mycological peptone, and 15.0 g of agar along with a novel chromogenic glucosaminidase substrate, ammonium 4-{2-[4-(2-acetamido-2-deoxy-β-d-glucopyranosyloxy)-3-methoxyphenyl]-vinyl}-1-(propan-3-yl-oate)-quinolium bromide (0.32 g liter−1). The glucosaminidase substrate in CDA was hydrolyzed by Candida albicans and Candida dubliniensis, yielding white colonies with deep-red spots on a yellow transparent background after 24 to 48 h of incubation at 37°C. Colonies of Candida tropicalis and Candida kefyr were uniformly pink, and colonies of other Candida spp., including Candida glabrata and Candida parapsilosis, were white. CDA was evaluated by using 115 test strains of Candida spp. and other clinically important yeasts and was compared with two commercially available chromogenic agars (Candida ID agar [bioMerieux] and CHROMagar Candida [CHROMagar Company Ltd.]). On all three agars, colonies of C. albicans were not distinguished from colonies of C. dubliniensis. However, for the group containing C. albicans plus C. dubliniensis, both the sensitivity and the specificity of detection when CDA was used were 100%, compared with values of 97.6 and 100%, respectively, with CHROMagar Candida and 100 and 96.8%, respectively, with Candida ID agar. In addition, for the group containing C. tropicalis plus C. kefyr, the sensitivity and specificity of detection when CDA was used were also 100%, compared with 72.7 and 98.1%, respectively, with CHROMagar Candida. Candida ID agar did not differentiate C. tropicalis and C. kefyr strains but did differentiate members of a broader group (C. tropicalis, C. kefyr, Candida lusitaniae plus Candida guilliermondii); the sensitivity and specificity of detection for members of this group were 94.7 and 93.8%, respectively. In addition to the increased sensitivity and/or specificity of Candida detection when CDA was used, differentiation of colony types on CDA (red spotted, pink, or no color) was unambiguous and did not require precise assessment of colony color. PMID:12089051

  9. Automated measurement of estrogen receptor in breast cancer: a comparison of fluorescent and chromogenic methods of measurement

    PubMed Central

    Zarrella, Elizabeth; Coulter, Madeline; Welsh, Allison; Carvajal, Daniel; Schalper, Kurt; Harigopal, Malini; Rimm, David; Neumeister, Veronique

    2016-01-01

    While FDA approved methods of assessment of Estrogen Receptor (ER) are “fit for purpose”, they represent a 30-year-old technology. New quantitative methods, both chromogenic and fluorescent, have been developed and studies have shown that these methods increase the accuracy of assessment of ER. Here, we compare three methods of ER detection and assessment on two retrospective tissue microarray cohorts of breast cancer patients: estimates of percent nuclei positive by pathologists and by Aperio’s nuclear algorithm (standard chromogenic immunostaining), and immunofluorescence as quantified with the AQUA® method of quantitative immunofluorescence (QIF). Reproducibility was excellent (R2 > 0.95) between users for both automated analysis methods, and the Aperio and QIF scoring results were also highly correlated, despite the different detection systems. The subjective readings show lower levels of reproducibility and a discontinuous, bimodal distribution of scores not seen by either mechanized method. Kaplan-Meier analysis of 10-year disease-free survival was significant for each method (Pathologist, P=0.0019; Aperio, P=0.0053, AQUA, P=0.0026), but there were discrepancies in patient classification in 19 out of 233 cases analyzed. Out of these, 11 were visually positive by both chromogenic and fluorescent detection. In 10 cases, the Aperio nuclear algorithm labeled the nuclei as negative, in 1 case, the AQUA score was just under the cutoff for positivity (determined by an Index TMA). In contrast, 8 out of 19 discrepant cases had clear nuclear positivity by fluorescence that was unable to be visualized by chromogenic detection, perhaps due to low positivity masked by the hematoxylin counterstain. These results demonstrate that automated systems enable objective, precise quantification of ER. Furthermore immunofluorescence detection offers the additional advantage of a signal that cannot be masked by a counterstaining agent. These data support the usage of automated methods for measurement of this and other biomarkers that may be used in companion diagnostic tests. PMID:27348626

  10. [The changes of alpha 2-plasmin inhibitor, and notably urokinase activities in blood measured by synthetic chromogenic substrates S-2444 after urokinase administration].

    PubMed

    Itoh, Y; Tsuji, K; Tanaka, N; Yamada, M; Nakanishi, M; Ishihara, M; Kobayashi, M

    1983-01-01

    Thrombolytic therapy with Urokinase (UK) has often been successful but it is very difficult to determine the effective dosage of UK. It is reported that after UK administration, plasmin fibrinolytic activity was immediately inhibited by alpha 2-Plasmin inhibitor (alpha 2-PI). In this study, we used UK on patients with myoma to prevent the occurrence of thrombosis after operation and the initial decrease in alpha 2-PI activities following UK administration was investigated to determine the minimum effective dosage of UK required to suppress alpha 2-PI. An attempt was also made to measure UK activity in blood by means of chromogenic substrate S-2444, and in some cases by administering 60,000 I.U. UK, alpha 1-Antitrypsin (alpha 1-AT), alpha 2-Macroglobulin (alpha 2-M), Antithrombin III (AT III) and Plasminogen (Plg) were measured at the same time. The results were as follows: 1) By the drip infusion method. In all doses, alpha 2-PI and UK activity showed no remarkable change. 2) By the one shot method. a) A decrease in alpha 2-PI was observed following both 48,000 and 60,000 I.U. UK administration. It was noted that in the case of 48,000 I.U. UK, alpha 2-PI showed the lowest level, 60% of the pre-administration level. b) UK activity showed a gradual increase in the case of 60,000 I.U. UK only and large changes in the other cases. c) alpha 1-AT, alpha 2-M, AT III and Plg produced no remarkable changes. This indicated that the effective dosage of UK for suppressing alpha 2-PI was at least 48,000 I.U. UK with the one shot method, and alpha 2-PI is a reliable indicator of the effectiveness of UK therapy.

  11. Fluorogenic Ag+–Tetrazolate Aggregation Enables Efficient Fluorescent Biological Silver Staining

    PubMed Central

    Xie, Sheng; Wong, Alex Y. H.; Kwok, Ryan T. K.; Li, Ying; Su, Huifang; Lam, Jacky W. Y.

    2018-01-01

    Abstract Silver staining, which exploits the special bioaffinity and the chromogenic reduction of silver ions, is an indispensable visualization method in biology. It is a most popular method for in‐gel protein detection. However, it is limited by run‐to‐run variability, background staining, inability for protein quantification, and limited compatibility with mass spectroscopic (MS) analysis; limitations that are largely attributed to the tricky chromogenic visualization. Herein, we reported a novel water‐soluble fluorogenic Ag+ probe, the sensing mechanism of which is based on an aggregation‐induced emission (AIE) process driven by tetrazolate‐Ag+ interactions. The fluorogenic sensing can substitute the chromogenic reaction, leading to a new fluorescence silver staining method. This new staining method offers sensitive detection of total proteins in polyacrylamide gels with a broad linear dynamic range and robust operations that rival the silver nitrate stain and the best fluorescent stains. PMID:29575702

  12. Biochemical Assays of Cultured Cells

    NASA Technical Reports Server (NTRS)

    Barlow, G. H.

    1985-01-01

    Subpopulations of human embryonic kidney cells isolated from continuous flow electrophoresis experiments performed at McDonnell Douglas and on STS-8 have been analyzed. These analyses have included plasminogen activator assays involving indirect methodology on fibrin plated and direct methodology using chromogenic substrates. Immunological studies were performed and the conditioned media for erythropoietin activity and human granulocyte colony stimulating (HGCSF) activity was analyzed.

  13. Arylethynyl receptors for neutral molecules and anions: emerging applications in cellular imaging.

    PubMed

    Carroll, Calden N; Naleway, John J; Haley, Michael M; Johnson, Darren W

    2010-10-01

    This critical review will focus on the application of shape-persistent receptors for anions that derive their rigidity and optoelectronic properties from the inclusion of arylethynyl linkages. It will highlight a few of the design strategies involved in engineering selective and sensitive fluorescent probes and how arylacetylenes can offer a design pathway to some of the more desirable properties of a selective sensor. Additionally, knowledge gained in the study of these receptors in organic media often leads to improved receptor design and the production of chromogenic and fluorogenic probes capable of detecting specific substrates among the multitude of ions present in biological systems. In this ocean of potential targets exists a large number of geometrically distinct anions, which present their own problems to the design of receptors with complementary binding for each preferred coordination geometry. Our interest in targeting charged substrates, specifically how previous work on receptors for cations or neutral guests can be adapted to anions, will be addressed. Additionally, we will focus on the design and development of supramolecular arylethynyl systems, their shape-persistence and fluorogenic or chromogenic optoelectronic responses to complexation. We will also examine briefly how the "chemistry in the cuvet" translates into biological media (125 references).

  14. Immunocytochemistry associated with oral exfoliative cytology: methodological analysis..

    PubMed

    da Silva, Alessandra Dutra; Lima, Celina Faig; Maraschin, Bruna Jalfim; Laureano, Natália Koerich; Daroit, Natália Batista; Brochier, Fernanda; Sant'Ana Filho, Manoel; Visioli, Fernanda; Rados, Pantelis Varvaki

    2015-04-01

    To evaluate different immunocytochemical protocol variations to find the most effective protocol for the analysis of involucrin, epidermal growth factor receptor (EGFR), and E-cadherin antibodies. Exfoliative cytology is a noninvasive method used to monitor and screen for early changes in the oral mucosa of patients exposed to carcinogens such as tobacco and alcohol. It has been postulated that its association with immunocytochemistry may improve the effectiveness of the screening process. Four graduate students from Porto Alegre in southern Brazil had oral smears collected from the border of the tongue using a cytobrush. The following variables were analyzed: cell membrane permeability, antigen retrieval method (microwave oven or water bath), antibody incubation time (overnight or 1 hour), detection system used (Envision or LSAB), and chromogen incubation time (10 seconds or 5 minutes). Best results were obtained with the following combinations: (1) for involucrin: water bath, 1-hour incubation for primary antibody, Envision, and chromogen incubation for 10 seconds; (2)for EGFR: microwave, overnight incubation, LSAB, and chromogen incubation for 5 minutes; and (3) for E-cadherin: water bath, over-night incubation, Envision, and chromogen incubation for 5 minutes. Our findings suggest that each antibody requires a specific immunocytochemical protocol to guarantee optimal results with oral smears.

  15. [Presumptive identification of Candida spp. and other clinically important yeasts: usefulness of Brilliance Candida Agar].

    PubMed

    Alfonso, Claudia; López, Mónica; Arechavala, Alicia; Perrone, María Del Carmen; Guelfand, Liliana; Bianchi, Mario

    2010-06-30

    Fungal infections caused by yeasts have increased during the last decades and invasive forms represent a serious problem for human health. Candida albicans is the species most frequently isolated from clinical samples. However, other emerging yeast pathogens are increasingly responsible for mycotic infections, and some of them are resistant to some antifungal drugs. Consequently, it is necessary to have methods that can provide a rapid presumptive identification at species level. Numerous chromogenic agar media have been shown to be of value as diagnostic tools. We have compared a chromogenic medium, Brilliance Candida Agar, with CHROMagar Candida, the chromogenic medium most used in our country. A multicentre study was conducted in 16 Hospitals belonging to the Mycology Net of Buenos Aires City Government. A total of 240 yeast isolates were included in this research. The new chromogenic agar showed results very similar to those obtained with CHROMagar Candida. Copyright 2009 Revista Iberoamericana de Micología. Published by Elsevier Espana. All rights reserved.

  16. Detection of oxacillin-susceptible mecA-positive Staphylococcus aureus isolates by use of chromogenic medium MRSA ID.

    PubMed

    Kumar, V Anil; Steffy, Katherin; Chatterjee, Maitrayee; Sugumar, Madhan; Dinesh, Kavitha R; Manoharan, Anand; Karim, Shamsul; Biswas, Raja

    2013-01-01

    Reports of oxacillin-susceptible mecA-positive Staphylococcus aureus strains are on the rise. Because of their susceptibility to oxacillin and cefoxitin, it is very difficult to detect them by using routine phenotypic methods. We describe two such isolates that were detected by chromogenic medium and confirmed by characterization of the mecA gene element.

  17. Inhibition of trypsin by condensed tannins and wine.

    PubMed

    Gonçalves, Rui; Soares, Susana; Mateus, Nuno; de Freitas, Victor

    2007-09-05

    Phenolic compounds are abundant vegetable secondary metabolites in the human diet. The ability of procyanidin oligomers and wine polyphenols to inhibit trypsin activity was studied using a versatile and reliable in vitro method. The hydrolysis of the chromogenic substrate N-benzoyl-d,l-arginine-p-nitroanilide (BApNA) by trypsin was followed by spectrophotometry in the presence and absence of condensed tannins and wine. A clear relationship between the degree of polymerization of procyanidins and enzymatic inhibition was observed. Trypsin activity inhibition was also detected in several types of wine. In general, the inhibition increased with the concentration of phenolic compounds in wines. These results may be relevant when considering these compounds as antinutritional factors, thereby contributing to a reduced absorption of nutrients.

  18. Can the diagnosis of recurrent vulvovaginal candidosis be improved by use of vaginal lavage samples and cultures on chromogenic agar?

    PubMed Central

    Novikova, N; Rodrigues, A; Mårdh, P A

    2002-01-01

    OBJECTIVE: To investigate if introital and vaginal flushing samples inoculated on chromogenic agar could increase the recovery rate and rapid identification of Candida and non-albicans species, as compared to culture of posterior vaginal fornix samples on Sabouraud agar and speciation of isolates by biochemical tests. METHODS: Samples from the introitus and the posterior vaginal fornix and vaginal lavage samples were collected from 91 women with a history suggestive of recurrent vulvovaginal candidosis (RVVC), and with a suspected new attack of the condition. The specimens were cultured on Sabouraud and CHROMagar. Speciation of yeast isolates was made on the chromogenic agar by API 32C kits and by an atomized system (Vitek). RESULTS: Forty-six (51%) women were positive for Candida from one or more of the samples. The introital cultures were positive in 43 (47%) women, both on Sabouraud and chromogenic agar. From the posterior vaginal fomix, 42 (46%) women were positive on the Sabouraud and 43 (47%) on chromogenic agar cultures, while the vaginal lavage cultures yielded Candida on those two media in 40 (44%) and 41 (45%) cases, respectively. Candida albicans was the most frequent species recovered, from 40 (87%) cases, followed by C. krusei in 4 (9%), C. glabrata in 2 (4%), and C. parapsilosis in one case. There was only one woman who had a mixed yeast infection, by C. albicans and C. krusei. There was only one discrepancy in the speciation as demonstrated by mean of chromogenic agar and API 32C kit. CONCLUSIONS: Neither cultures of introital nor of vaginal lavage samples increases the detection rate of Candida in RVVC cases as compared to cultures of posterior vaginal fornix samples. Use of chromogenic agar is a convenient and reliable means to detect colonization by Candida and differentiate between C. albicans and non-albicans species. PMID:12530485

  19. Enzymatic Spectrophotometric Reaction Rate Determination of Glucose in Fruit Drinks and Carbonated Beverages. An Analytical Chemistry Laboratory Experiment for Food Science-Oriented Students

    NASA Astrophysics Data System (ADS)

    Vasilarou, Argyro-Maria G.; Georgiou, Constantinos A.

    2000-10-01

    The glucose oxidase-horseradish peroxidase coupled reaction using phenol and 4-aminoantipyrine is used for the kinetic determination of glucose in drinks and beverages. This laboratory experiment demonstrates the implementation of reaction rate kinetic methods of analysis, the use of enzymes as selective analytical reagents for the determination of substrates, the kinetic masking of ascorbic acid interference, and the analysis of glucose in drinks and beverages. The method is optimized for student use in the temperature range of 18-28 °C and can be used in low-budget laboratories equipped with an inexpensive visible photometer. The mixed enzyme-chromogen solution that is used is stable for two months. Precision ranged from 5.1 to 12% RSD for analyses conducted during a period of two months by 48 students.

  20. Aqueous extract from Brownea grandiceps flowers with effect on coagulation and fibrinolytic system.

    PubMed

    Pereira, Betzabeth; Brazón, Josmary

    2015-02-03

    Brownea grandiceps flowers are used in Venezuelan folk medicine as anti-hemorrhagic in women with heavy menstrual blood loss (menorrhagia). However, prior to this study, there were no scientific investigations to support this fact, because the aqueous extract from Brownea grandiceps flowers had not been previously evaluated neither phytochemically nor biologically. The objective of this work was to evaluate in vitro the effects of aqueous extract from Brownea grandiceps flowers on the coagulation system and fibrinolysis. An infusion of Brownea grandiceps flowers (160g) was performed; then, it was homogenized, centrifuged and lyophilized to obtain the aqueous extract, and this was called BGE. Subsequently, the extract was characterized on the one hand, phytochemically and on the other hand, biologically, employing prothrombin time (PT), partial thromboplastin time (PTT) and thrombin time (TT) to determine the effects on extrinsic, intrinsic and common coagulation pathways, respectively. In addition to that, the fibrinogenolytic and fibronectinase activity was evaluated by SDS-PAGE using Tris-Tricine system and analyzed by densitometric study utilizing ImageJ program. Also, by using specific chromogenic substrates for Factor Xa (FXa), thrombin, tissue plasminogen activator (t-PA), urokinase plasminogen activator (u-PA) and plasmin, it was assessed whether BGE exhibited some enzyme-like activity, and inhibitory activity of the afore mentioned enzymes. Fibrinolytic and antifibrinolytic activities were determined by a fibrin plate method. Data were analyzed by an nonparametric method. BGE presented tannins, saponins, glycosides, alkaloids, flavonoids, coumarins, and did not contain triterpenoids and steroids. Also, BGE at low concentrations (250-1250µg/mL) reduced the PT, while higher concentrations (15000-25000µg/mL) prolonged this time. However, BGE concentrations between 1250 and 25000µg/mL prolonged the PTT. Prolongation of PT and PTT was observed at high concentrations and was due to FXa inhibitor found in BGE and this effect could be strengthened by degradation of fibrinogen and fibronectin, which were also produced by BGE. Moreover, BGE did not clot fibrinogen or human plasma, and neither did it cleave the chromogenic substrates specific to FXa nor thrombin. These results suggest the pro-coagulant components could be acting on some factor of the extrinsic pathway, since only PT was shortened. Furthermore, BGE did not hydrolyze the chromogenic substrate specific to plasmin, t-PA and u-PA nor did it produce fibrin degradation. However, all BGE concentrations tested inhibited the plasmin activity in a dose-dependent manner. The outcomes of this study reveal the presence of fibrinogenolytic, fibronectinase and anti-FXa components in BGE, plus anti-plasmin compounds that could be acting as antifibrinolytic, thus delaying the fibrin degradation in pathophysiological processes, as it has been observed in women presenting with menorrhagia due to a high plasmin concentration. Where this anti-plasmin compound, along with pro-coagulant components also present in BGE, could be made responsible for reducing heavy menstrual bleeding in women, since a deficiency in one or more blood coagulation factors such as factor VII, V or X, is a potential cause of menorrhagia. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Construction of promoter-probe shuttle vectors for Escherichia coli and corynebacteria on the basis of promoterless alpha-amylase gene.

    PubMed

    Ugorcáková, J; Bukovská, G; Timko, J

    2000-01-01

    We constructed new promoter-probe vectors for E. coli and corynebacteria based on the promoterless alpha-amylase gene originating from Bacillus subtilis. Vectors pJUPAE1 and pJUPAE2 are suitable for isolation of transcriptionally active fragments from plasmids, phages or genomic DNA. alpha-Amylase activity can be easily visually detected on agar plates containing a chromogenic substrate, or by direct measurement of alpha-amylase activity.

  2. Selective chromogenic detection of thiol-containing biomolecules using carbonaceous nanospheres loaded with silver nanoparticles as carrier.

    PubMed

    Hu, Bo; Zhao, Yang; Zhu, Hai-Zhou; Yu, Shu-Hong

    2011-04-26

    Thiol-containing biomolecules show strong affinity with noble metal nanostructures and could not only stably protect them but also control the self-assembly process of these special nanostructures. A highly selective and sensitive chromogenic detection method has been designed for the low and high molecular weight thiol-containing biomolecules, including cysteine, glutathione, dithiothreitol, and bovine serum albumin, using a new type of carbonaceous nanospheres loaded with silver nanoparticles (Ag NPs) as carrier. This strategy relies upon the place-exchange process between the reporter dyes on the surface of Ag NPs and the thiol groups of thiol-containing biomolecules. The concentration of biomolecules can be determined by monitoring with the fluorescence intensity of reporter dyes dispersed in solution. This new chromogenic assay method could selectively detect these biomolecules in the presence of various other amino acids and monosaccharides and even sensitively detect the thiol-containing biomolecules with different molecular weight, even including proteins.

  3. A novel chromogenic medium for isolation of Pseudomonas aeruginosa from the sputa of cystic fibrosis patients.

    PubMed

    Laine, Larissa; Perry, John D; Lee, Jenner; Oliver, Michelle; James, Arthur L; De La Foata, Corinne; Halimi, Diane; Orenga, Sylvain; Galloway, Angela; Gould, F Kate

    2009-03-01

    A novel chromogenic medium for isolation and identification of Pseudomonas aeruginosa from sputa of cystic fibrosis (CF) patients was evaluated and compared with standard laboratory methods. One hundred sputum samples from distinct CF patients were cultured onto blood agar (BA), Pseudomonas CN selective agar (CN) and a Pseudomonas chromogenic medium (PS-ID). All Gram-negative morphological variants from each medium were subjected to antimicrobial susceptibility testing, and identification using a combination of biochemical and molecular methods. P. aeruginosa was isolated from 62 samples after 72 h incubation. Blood agar recovered P. aeruginosa from 56 samples (90.3%) compared with 59 samples (95.2%) using either CN or PS-ID. The positive predictive value of PS-ID (98.3%) was significantly higher than growth on CN (88.5%) for identification of P. aeruginosa (P<0.05). PS-ID is a promising medium allowing for the isolation and simultaneous identification of P. aeruginosa from sputa of CF patients.

  4. Evaluation of a Method for Rapid Detection of Listeria monocytogenes in Dry-Cured Ham Based on Impedanciometry Combined with Chromogenic Agar.

    PubMed

    Labrador, Mirian; Rota, María C; Pérez, Consuelo; Herrera, Antonio; Bayarri, Susana

    2018-05-01

    The food industry is in need of rapid, reliable methodologies for the detection of Listeria monocytogenes in ready-to-eat products, as an alternative to the International Organization of Standardization (ISO) 11290-1 reference method. The aim of this study was to evaluate impedanciometry combined with chromogenic agar culture for the detection of L. monocytogenes in dry-cured ham. The experimental setup consisted in assaying four strains of L. monocytogenes and two strains of Listeria innocua in pure culture. The method was evaluated according to the ISO 16140:2003 standard through a comparative study with the ISO reference method with 119 samples of dry-cured ham. Significant determination coefficients ( R 2 of up to 0.99) for all strains assayed in pure culture were obtained. The comparative study results had 100% accuracy, 100% specificity, and 100% sensitivity. Impedanciometry followed by chromogenic agar culture was capable of detecting 1 CFU/25 g of food. L. monocytogenes was not detected in the 65 commercial samples tested. The method evaluated herein represents a promising alternative for the food industry in its efforts to control L. monocytogenes. Overall analysis time is shorter and the method permits a straightforward analysis of a large number of samples with reliable results.

  5. Staphylococcus chromogenes, a Coagulase-Negative Staphylococcus Species That Can Clot Plasma.

    PubMed

    Dos Santos, Danielle Cabral; Lange, Carla Christine; Avellar-Costa, Pedro; Dos Santos, Katia Regina Netto; Brito, Maria Aparecida Vasconcelos Paiva; Giambiagi-deMarval, Marcia

    2016-05-01

    Staphylococcus chromogenes is one of the main coagulase-negative staphylococci isolated from mastitis of dairy cows. We describe S. chromogenes isolates that can clot plasma. Since the main pathogen causing mastitis is coagulase-positive Staphylococcus aureus, the coagulase-positive phenotype of S. chromogenes described here can easily lead to misidentification. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  6. Chromogenic Detection of Dipeptidyl Peptidase IV (DPP-IV) Activity using Peptide-Functionalized Gold Nanoparticles

    NASA Astrophysics Data System (ADS)

    Abul-Huda, Yasin Mohammad

    Metal nanoparticles offer a useful platform for a wide range of biological applications especially for biosensing, bioimaging and drug delivery. This thesis presents a body of original research describing the synthesis, characterisation and development of a novel and convenient biosensing assay for detection of dipeptidyl peptidase IV (DPP-IV) enzyme activity using peptide functionalized gold nanoparticles. The distinctive optical and physical properties of gold nanoparticles (Au NP) were harnessed for the development of a colorimetric assay for rapid sensing of DPP-IV activities and screening DPP-IV inhbitors. The citrate reduction method for Au NPs synthesis was optimised and several potential peptide substrates (GPDC, VP-EN-DC, C/G dipeptide, GPG-EN-PEG4-LA, GPDCALNNC) were designed to provide substrates that mimic the DPP-IV natural substrates. The performances of the substrate functionalized Au NPs were assessed for their appropriateness for the detection of the enzyme activity. Addition of DPP-IV to the solutions containing the functionalized Au NPs resulted in cleavage of the substrate and thus causing the aggregation of the Au NPs which in turn led to a shift of the surface plasmon peak toward longer wavelengths, and a change of the colour of the colloidal suspension from red to blue. Overall, real-time detection of DPP-IV activity over a broader range (0-40 U/L) with high selectivity and stability was obtained, thus providing a method that can be used to determine the levels of DPP-IV/CD26 in biological fluids such as serum and plasma. Further assay developments were conducted to overcome limitations encountered with the original Au NP assay, especially the narrow dynamic linear range and stability in high ionic strength solutions. Validation and comparison of the Au NP assay developed has revealed that this method is highly correlated to the gold standard chromogenic Gly-Pro-pNA method for detection of enzyme activity in biological samples. Very good recoveries (in the range 83.6 -114.9%) were obtained in spiked serum samples, which indicate that this assay could provide a suitable alternative for enzyme activity detection with the naked eye and without the need for sophisticated instruments. Investigations into the effects of incorporating different stabilizers in order to improve the stability of the peptide functionalized Au NP in high ionic strength solutions were also investigated. Gold nanoparticles have different shapes and structures and an alternative approach for detection of DPP-IV activity using gold nanorods due to their higher refractive index sensitivities was explored. As a conclusion, three out of five approaches, all utilising Au NP-ligand conjugates were demonstrated useful for the detection of the DPP-IV activity. The system developed here is portable and would permit on-site analysis of samples, which offers a real alternative approach from traditional assays and reduces the need for laboratory testing. The logical next step in this research would be the continuation of experiments to transform this test into a point of care testing device that could offer an early detection tool for disease management.

  7. Measurement of Nonribosomal Peptide Synthetase Adenylation Domain Activity Using a Continuous Hydroxylamine Release Assay.

    PubMed

    Duckworth, Benjamin P; Wilson, Daniel J; Aldrich, Courtney C

    2016-01-01

    Adenylation is a crucial enzymatic process in the biosynthesis of nonribosomal peptide synthetase (NRPS) derived natural products. Adenylation domains are considered the gatekeepers of NRPSs since they select, activate, and load the carboxylic acid substrate onto a downstream peptidyl carrier protein (PCP) domain of the NRPS. We describe a coupled continuous kinetic assay for NRPS adenylation domains that substitutes the PCP domain with hydroxylamine as the acceptor molecule. The pyrophosphate released from the first-half reaction is then measured using a two-enzyme coupling system, which detects conversion of the chromogenic substrate 7-methylthioguanosine (MesG) to 7-methylthioguanine. From profiling substrate specificity of unknown or engineered adenylation domains to studying chemical inhibition of adenylating enzymes, this robust assay will be of widespread utility in the broad field NRPS enzymology.

  8. Bluephage: A rapid method for the detection of somatic coliphages used as indicators of fecal pollution in water.

    PubMed

    Muniesa, M; Ballesté, E; Imamovic, L; Pascual-Benito, M; Toribio-Avedillo, D; Lucena, F; Blanch, A R; Jofre, J

    2018-01-01

    The use of somatic coliphages as indicators of fecal and viral pollution in water and food has great potential due to the reliability, reproducibility, speed and cost effectiveness of methods for their detection. Indeed, several countries already use this approach in their water management policies. Although standardized protocols for somatic coliphage detection are available, user-friendly commercial kits would facilitate their routine implementation in laboratories. The new method presented here allows detection of up to 1 somatic coliphage in under 3.5 h, well within one working day. The method is based on a modified Escherichia coli strain with knocked-out uidB and uidC genes, which encode the transport of glucuronic acid inside cells, and overexpressing uidA, which encodes the enzyme β-glucuronidase. The enzyme accumulated in the bacterial cells only has contact with its substrate after cell lysis, such as that caused by phages, since the strain cannot internalize the substrate. When the enzyme is released into the medium, which contains a chromogen analogous to glucuronic acid, it produces a change of color from yellow to dark blue. This microbiological method for the determination of fecal pollution via the detection of culturable microorganisms can be applied to diverse sample types and volumes for qualitative (presence/absence) and quantitative analysis and is the fastest reported to date. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Development and evaluation of kinetic spectrophotometric assays for horseradish peroxidase by catalytic coupling of paraphenylenediamine and mequinol.

    PubMed

    Nagaraja, Padmarajaiah; Shivakumar, Anantharaman; Kumar Shrestha, Ashwinee

    2009-10-01

    This paper presents a novel spectrophotometric method to measure peroxidase activity using paraphenylenediamine dihydrochloride (PPDD) and Mequinol (MQ). The PPDD traps the free radical, and gets oxidized to electrophilic 1,4-diimine; this couples with MQ to an give intense violet-colored chromogenic species with the maximum absorbance at 560 nm. This assay was adopted for the quantification of hydrogen peroxide between 10 x 10(-6) to 80 x 10(-6) M. From the kinetic data, a two-substrate ping-pong mechanism of peroxidase was established. Catalytic efficiency and catalytic power of commercial peroxidase were 0.204 x 10(6) M(-1) min(-1) and 2.86 x 10(-4) min(-1), respectively. The catalytic constant (k(cat)) of the proposed method was 0.2080 x 10(3) min(-1). As a simple, rapid, precise and sensitive technique, PPDD-MQ stands as a potential replacement for the traditional guaiacol method. Applications to the plant extracts increase its relevance in the field of biochemical analysis.

  10. Monodispersed silica nanoparticles as carrier for co-immobilization of bi-enzyme and its application for glucose biosensing

    NASA Astrophysics Data System (ADS)

    Yang, Hao; Wei, Wei; Liu, Songqin

    A novel glucose sensing strategy by using bi-enzyme coated monodispered silica nanoparticles (SiO2) was proposed. The monodispered SiO2 was synthesized according to our previously reported seed-growth methods. Glucose oxidase (GOD) and horseradish peroxidase (HRP) were simultaneously covalent immobilized on the surface of SiO2 nanoparticles through the cross-linker of glutaraldehyde. The immobilized bi-enzyme remained their bioactivities well for the substrate reaction. Thus, the resultant SiO2-GOD/HRP nanocomposites could be used as catalyst for enzymatic substrate reactions in the presence of 3,3‧,5,5‧-tetramethylbenzidine (TMB) as chromogenic reagent and glucose as substrate. The factors of affecting the catalytic activities of enzymes were optimized. Under optimal conditions, the absorbance at 450 nm in UV-visible spectra increased with the glucose concentration, which could be used for glucose detection with a linear range from 0.5 μM to 250 μM and a detection limit of 0.22 μM at a signal-to-noise ratio of 3σ. Considering the potential of making pills using this SiO2-GOD/HRP, the present strategy has good prospect in the clinic science and other fields in future.

  11. Microdetermination of urea in urine using p-dimethylaminobenzaldehyde /PDAB/

    NASA Technical Reports Server (NTRS)

    Geiger, P. J.

    1969-01-01

    Adaptation of the p-dimethylaminobenzaldehyde method for determining urea concentration in urine is an improved micromechanical method. Accuracy and precision are satisfactory. This method avoids extra steps of deproteinizing or removing normal urinary chromogens.

  12. Usefulness of Chromogenic CromoCen® AGN agar medium for the identification of the genus Aeromonas: Assessment of faecal samples.

    PubMed

    Aguilera-Arreola, M G; Portillo-Muñoz, M I; Rodríguez-Martínez, C; Castro-Escarpulli, G

    2012-08-01

    Selective screening media for the detection and identification of Aeromonas strains are needed to guide primary isolation procedures in the clinical laboratory. This study compared the selective CromoCen® AGN chromogenic agar medium for the detection and identification of Aeromonas strains that were isolated from various samples against the conventional selective agar media that are commonly used for the isolation of this organism in food, environmental and clinical samples. The Miles and Misra and ecometric methods were used to evaluate the microbiological performance of CromoCen® AGN chromogenic agar medium, which was shown to be satisfactory. A total of 14 reference Aeromonas strains, 44 wild strains and 106 clinical stool specimens were examined using both non-chromogenic selective agars that are commonly used for Aeromonas isolation and CromoCen® AGN agar. The latter exhibited 94.73% sensitivity and 100% specificity for the various samples. On CromoCen® AGN agar medium, Aeromonas formed colonies with light green, greenish and salmon pigments with or without a surrounding wide transparent zone (halo) of 2-3mm in diameter around the entire border. This medium is recommended for the isolation and potential identification of the Aeromonas genus. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Automotive applications of chromogenic materials

    NASA Astrophysics Data System (ADS)

    Lynam, Niall R.

    1990-03-01

    Automobiles present both opportunities and challenges for large-area chromogenics. Opportunities include optical and thermal control of vehicle glazing along with optical control of rearview mirrors and privacy glass. Challenges include cost-effectively meeting automotive safety, performance, and reliability standards. Worldwide automobile production' for 1987 is listed in Table 1. Of the roughly 33 million cars produced annually, approximately 8% are luxury models which are candidates for features such as auto- matically dimming rearview mirrors or variable opacity sunroofs. Thus copious commercial opportunities await whatever chromogenic technologies qualify for use in automobiles. This review will describe the performance, safety, and reliability/durability required for automotive use. Commercial opportunities and challenges will be discussed including cost factors and specifications. Chromogenic technologies such as electrochromism, liquid crystals and thermochromism will be reviewed in terms of how publicly announced technical developments match automotive needs and expectations. Construction and performance of ex- isting or imminent chromogenic devices will be described. Finally, how opportunities and challenges of the automotive environment translate to other applications for chromogenic materials such as architectural or information display devices will be discussed. The objective is to generally review the applications, the technologies appropriate to these applications, and the automotive chromogenic devices available at the time of writing to match these applications.

  14. Qualification of a select one-stage activated partial thromboplastin time-based clotting assay and two chromogenic assays for the post-administration monitoring of nonacog beta pegol.

    PubMed

    Tiefenbacher, S; Bohra, R; Amiral, J; Bowyer, A; Kitchen, S; Lochu, A; Rosén, S; Ezban, M

    2017-10-01

    Essentials Nonacog beta pegol (N9-GP) is an extended half-life, recombinant human factor IX (FIX). One-stage clotting (OSC) and chromogenic FIX activity assays were assessed for N9-GP recovery. OSC STA ® -Cephascreen ® , ROX FIX and BIOPHEN FIX chromogenic assays were qualified for N9-GP. Other extended half-life factor products should be assessed in a similar way prior to approval. Background Nonacog beta pegol (N9-GP) is an extended half-life, glycoPEGylated recombinant human factor IX that is under development for the prophylaxis and treatment of bleeding episodes in hemophilia B patients. Considerable reagent-dependent variability has been observed when one-stage clotting assays are used to measure the recovery of recombinant FIX products, including N9-GP. Objective To qualify select one-stage clotting and chromogenic FIX activity assays for measuring N9-GP recovery. Methods The accuracy and precision of the one-stage clotting assay (with the STA-Cephascreen activated partial thromboplastin [APTT] reagent) and the ROX Factor IX and BIOPHEN Factor IX chromogenic assays for measuring N9-GP recovery were assessed in N9-GP-spiked hemophilia B plasma samples in a systematic manner at three independent sites, with manufacturer-recommended protocols and/or site-specific assay setups, including different instruments. Results For each of the three FIX activity assays qualified on five different reagent-instrument systems, acceptable intra-assay and interassay accuracy and precision, dilution integrity, reagent robustness and freeze-thaw and short-term sample stabilities were demonstrated. The STA-Cephascreen assay showed a limited reportable range at one of the three qualification sites, and the BIOPHEN Factor IX assay showed suspect low-end sensitivity at one of the three qualification sites. An individual laboratory would account for these limitations by adjusting the assay's reportable range; thus, these findings are not considered to impact the respective assay qualifications. Conclusion The one-stage clotting assay with the STA-Cephascreen APTT reagent, the ROX Factor IX chromogenic assay and the BIOPHEN Factor IX chromogenic assay are considered to be qualified for the measurement of N9-GP in 3.2% (0.109 m) citrated human plasma. © 2017 International Society on Thrombosis and Haemostasis.

  15. Streptomycin interference in Jaffe reaction - possible false positive creatinine estimation in excessive dose exposure.

    PubMed

    Syal, Kirtimaan; Srinivasan, Anand; Banerjee, Dibyajyoti

    2013-01-01

    To study the potential of commonly used aminoglycoside antibiotics to form non-creatinine chromogen with alkaline picrate reagent. We studied the non-creatinine chromogen formation of various concentrations of streptomycin, amikacin, kanamycin, netilmicin, gentamicin and tobramycin added to known creatinine concentrations by the Jaffe reaction based creatinine estimation. Only streptomycin above therapeutic concentrations of 10mg/mL interfered in the Jaffe reaction and acted as non-creatinine chromogen. Therapeutic doses of the aminoglycosides do not form non-creatinine chromogens. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Comparison of MI, Chromocult® coliform, and Compass CC chromogenic culture-based methods to detect Escherichia coli and total coliforms in water using 16S rRNA sequencing for colony identification.

    PubMed

    Maheux, Andrée F; Bouchard, Sébastien; Bérubé, Ève; Bergeron, Michel G

    2017-06-01

    The MI, Chromocult ® coliform, and Compass CC chromogenic culture-based methods used to assess water quality by the detection of Escherichia coli and total coliforms were compared in terms of their specificity and sensitivity, using 16S rRNA sequencing for colony identification. A sewage water sample was divided in 2-μL subsamples for testing by all three culture-based methods. All growing colonies were harvested and subjected to 16S rRNA sequencing. Test results showed that all E. coli colonies were correctly identified by all three methods, for a specificity and a sensitivity of 100%. However, for the total coliform detection, the MI agar, Chromocult ® coliform agar, and Compass CC agar were specific for only 69.2% (9/13), 47.2% (25/53), and 40.5% (17/42), whereas sensitive for 97.8% (45/46), 97.5% (39/40), and 85.7% (24/28), respectively. Thus, given the low level of specificity of these methods for the detection of total coliforms, confirming the identity of total coliform colonies could help to take public health decisions, in particular for cities connected to a public drinking water distribution system since the growth of few putative total coliform colonies on chromogenic agar is problematic and can lead to unnecessary and costly boiling notices from public health authorities.

  17. Copper-Based Metal-Organic Framework Nanoparticles with Peroxidase-Like Activity for Sensitive Colorimetric Detection of Staphylococcus aureus.

    PubMed

    Wang, Shuqin; Deng, Wenfang; Yang, Lu; Tan, Yueming; Xie, Qingji; Yao, Shouzhuo

    2017-07-26

    Cu-MOF nanoparticles with an average diameter of 550 nm were synthesized from 2-aminoterephthalic acid and Cu(NO 3 ) 2 by a mixed solvothermal method. The Cu-MOF nanoparticles can show peroxidase-like activity that can catalyze 3,3',5,5'-tetramethylbenzidine to produce a yellow chromogenic reaction in the presence of H 2 O 2 . The presence of abundant amine groups on the surfaces of Cu-MOF nanoparticles enables facile modification of Staphylococcus aureus (S. aureus) aptamer on Cu-MOF nanoparticles. By combining Cu-MOF-catalyzed chromogenic reaction with aptamer recognition and magnetic separation, a simple, sensitive, and selective colorimetric method for the detection of S. aureus was developed.

  18. Evaluation of two commercially available chromogenic media for confirmation of methicillin-resistant Staphylococcus aureus from human, animal, and food samples.

    PubMed

    Ariza-Miguel, Jaime; Oniciuc, Elena-Alexandra; Sanz, Iván; Fernández-Natal, Isabel; Hernández, Marta; Rodríguez-Lázaro, David

    2015-09-16

    We compared the diagnostic performance of two chromogenic media, Brilliance MRSA 2 agar (Thermo Fisher Scientific) and ChromID MRSA agar (bioMérieux), for MRSA confirmation of 239 Staphylococcus aureus isolates from clinical, animal and food samples. Statistically significant differences were not observed between MRSA confirmation by mecA/mecC PCR, and by culture in both chromogenic media. However, a statistically significant difference was observed between the results obtained by both chromogenic media (p = 0.003). Segregated analysis of the results depending on the origin of the isolates (clinical, animal, and food) revealed a significant lower performance in the MRSA confirmation of food-derived isolates by using Brilliance MRSA 2 agar in comparison to PCR confirmation (p = 0.003) or ChromID MRSA agar (p<0.001). Both chromogenic media provided a good diagnostic performance for detection of MRSA isolates of human and animal origin. In conclusion, the use of chromogenic agar plates for MRSA confirmation of S. aureus isolates can provide a good diagnostic performance (sensitivity >92% and specificity >89%) regardless of the type of chromogenic media used or the origin of the S. aureus isolates. However, our results revealed a lower diagnostic performance for MRSA confirmation of S. aureus isolates from food samples by using Brilliance MRSA 2 agar. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. A selective spectrophotometric method for determination of rosoxacin antibiotic using sodium nitroprusside as a chromogenic reagent

    NASA Astrophysics Data System (ADS)

    Askal, Hassan F.; Refaat, Ibrahim H.; Darwish, Ibrahim A.; Marzouq, Mostafa A.

    2008-04-01

    A selective spectrophotometric method for the determination of rosoxacin (ROS), a 4-quinolone antimicrobial agent, has been developed and validated. The method was based on the reaction of ROS with alkaline sodium nitroprusside (SNP) reagent at room temperature forming a red colored chromogen measured at 455 nm. The conditions affecting the reaction (SNP concentration, pH, color-developing time, temperature, diluting solvent and chromogen stability time) were optimized. Under the optimum conditions, good linear relationship ( r = 0.9987) was obtained between the absorbance and the concentration of ROS in the range of 20-50 μg ml -1. The assay limits of detection and quantitation were 2.5 and 8.4 μg ml -1, respectively. The method was successfully applied to the analysis of bulk drug and laboratory-prepared tablets; the mean percentage recoveries were 100.1 ± 0.33 and 101.24 ± 1.28%, respectively. The results were compared favourably with those obtained by the reported method; no significant difference in the accuracy and precision as revealed by the accepted values of t- and F-tests, respectively. The robustness and ruggedness of the method was checked and satisfactory results were obtained. The proposed method was found to be highly selective for ROS among the fluoroquinolone antibiotics. The reaction mechanism was proposed and it proceeded in two steps; the formation of nitroferrocyanide by the action of sodium hydroxide alkalinity on SNP and the subsequent formation of the colored nitrosyl-ROS derivative by the attack at position 6 of ROS.

  20. Continuous flow immobilized enzyme reactor-tandem mass spectrometry for screening of AChE inhibitors in complex mixtures.

    PubMed

    Forsberg, Erica M; Green, James R A; Brennan, John D

    2011-07-01

    A method is described for identifying bioactive compounds in complex mixtures based on the use of capillary-scale monolithic enzyme-reactor columns for rapid screening of enzyme activity. A two-channel nanoLC system was used to continuously infuse substrate coupled with automated injections of substrate/small molecule mixtures, optionally containing the chromogenic Ellman reagent, through sol-gel derived acetylcholinesterase (AChE) doped monolithic columns. This is the first report of AChE encapsulated in monolithic silica for use as an immobilized enzyme reactor (IMER), and the first use of such IMERs for mixture screening. AChE IMER columns were optimized to allow rapid functional screening of compound mixtures based on changes in the product absorbance or the ratio of mass spectrometric peaks for product and substrate ions in the eluent. The assay had robust performance and produced a Z' factor of 0.77 in the presence of 2% (v/v) DMSO. A series of 52 mixtures consisting of 1040 compounds from the Canadian Compound Collection of bioactives was screened and two known inhibitors, physostigmine and 9-aminoacridine, were identified from active mixtures by manual deconvolution. The activity of the compounds was confirmed using the enzyme reactor format, which allowed determination of both IC(50) and K(I) values. Screening results were found to correlate well with a recently published fluorescence-based microarray screening assay for AChE inhibitors.

  1. Clinical effectiveness of rapid tests for methicillin resistant Staphylococcus aureus (MRSA) in hospitalized patients: a systematic review

    PubMed Central

    2011-01-01

    Background Methicillin resistant Staphylococcus aureus (MRSA) are often resistant to multiple classes of antibiotics. The research objectives of this systematic review were to evaluate the clinical effectiveness of polymerase chain reaction (PCR) versus chromogenic agar for MRSA screening, and PCR versus no screening for several clinical outcomes, including MRSA colonization and infection rates. Methods An electronic literature search was conducted on studies evaluating polymerase chain reaction techniques and methicillin (also spelled meticillin) resistant Staphylococcus aureus that were published from 1993 onwards using Medline, Medline In-Process & Other Non-Indexed Citations, BIOSIS Previews, and EMBASE. Due to the presence of heterogeneity in the selected studies, the clinical findings of individual studies were described. Results Nine studies that compared screening for MRSA using PCR versus screening using chromogenic agar in a hospital setting, and two studies that compared screening using PCR with no or targeted screening were identified. Some studies found lower MRSA colonization and acquisition, infection, and transmission rates in screening with PCR versus screening with chromogenic agar, and the turnaround time for screening test results was lower for PCR. One study reported a lower number of unnecessary isolation days with screening using PCR versus screening with chromogenic agar, but the proportion of patients isolated was similar between both groups. The turnaround time for test results and number of isolation days were lower for PCR versus chromogenic agar for MRSA screening. Conclusions The use of PCR for MRSA screening demonstrated a lower turnaround time and number of isolation days compared with chromogenic agar. Given the mixed quality and number of studies (11 studies), gaps remain in the published literature and the evidence remains insufficient. In addition to screening, factors such as the number of contacts between healthcare workers and patients, number of patients attended by one healthcare worker per day, probability of colonization among healthcare workers, and MRSA status of hospital shared equipment and hospital environment must be considered to control the transmission of MRSA in a hospital setting. PMID:22151575

  2. Two new gene clusters involved in the degradation of plant cell wall from the fecal microbiota of Tunisian dromedary

    PubMed Central

    Ameri, Rihab; Laville, Elisabeth; Potocki-Véronèse, Gabrielle; Trabelsi, Sahar; Mezghani, Monia; Elgharbi, Fatma

    2018-01-01

    Dromedaries are capable of digesting plant cell wall with high content of lignocellulose of poor digestibility. Consequently, their intestinal microbiota can be a source of novel carbohydrate-active enzymes (CAZymes). To the best of our knowledge, no data are available describing the biochemical analysis of enzymes in dromedary intestinal microbiota. To investigate new hydrolytic enzymes from the dromedary gut, a fosmid library was constructed using metagenomic DNA from feces of non-domestic adult dromedary camels living in the Tunisian desert. High-throughput functional screening of 13756 clones resulted in 47 hit clones active on a panel of various chromogenic and non-chromogenic glycan substrates. Two of them, harboring multiple activities, were retained for further analysis. Clone 26H3 displayed activity on AZO-CM-cellulose, AZCL Carob galactomannan and Tween 20, while clone 36A23 was active on AZCL carob galactomannan and AZCL barley β-glucan. The functional annotation of their sequences highlighted original metagenomic loci originating from bacteria of the Bacteroidetes/Chlorobi group, involved in the metabolization of mannosides and β-glucans thanks to a complete battery of endo- and exo-acting glycoside hydrolases, esterases, phosphorylases and transporters. PMID:29601586

  3. Dithizone as novel and efficient chromogenic probe for cyanide detection in aqueous media through nucleophilic addition into diazenylthione moiety.

    PubMed

    Tavallali, Hossein; Deilamy-Rad, Gohar; Parhami, Abolfath; Kiyani, Sajede

    2014-01-01

    A new selective chemodosimeter probe was developed by the introduction of dithizone (DTZ) as a simple and available dye for detection of cyanide in aqueous media which enables recognition of cyanide over other competing anions such as acetate, dihydrogen phosphate, fluoride and benzoate through covalent bonding. The sensing properties of DTZ were investigated in DMSO/H2O (1:9) and have demonstrated a very high selectivity toward the cyanide anions. A reasonable recognition mechanism was suggested using UV-Vis, (1)H NMR and FTIR spectroscopy techniques. Time dependent density function theory (TDDFT) computations of UV-Vis excitation for DTZ2-CN adduct agreed well with our experimental findings. The detection limit of the new chromogenic probe was measured to be 0.48 μmol L(-1) which is much lower than most recently reported chromogenic probes for cyanide determination. The analytical utility of the method for the analysis of cyanide ions in electroplating wastewater (EPWW), human serum, tap and mineral water samples was demonstrated and the results were compared successfully with the conventional reference method. The short time response and the detection by the naked eye make the method available for the detection and quantitative determination of cyanide in a variety of real samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Effects of Chitosan Derivative N-[(2-Hydroxy-3-Trimethylammonium)Propyl]Chloride on Anticoagulant Activity of Guinea Pig Plasma.

    PubMed

    Drozd, N N; Shagdarova, B Ts; Il'ina, A V; Varlamov, V P

    2017-07-01

    Intravenous injection of protamine sulfate or quarternized chitosan derivative to guinea pigs after injection of 70 aIIa U/kg non-fractionated heparin shortened plasma clotting time (shown by partial activated thromboplastin time, thrombin time, and prothrombin time). Intravenous injection of protamine sulfate or quarternized chitosan derivative to guinea pigs after injection of 1 mg/kg (100 aXa U/kg) low-molecular-weight heparin (clexane) led to shortening of plasma clotting time in the ReaClot Heparin test and to prolongation of plasma amidolytic activity in the factor Xa chromogenic substrate test.

  5. Selective chromogenic and fluorogenic peptide substrates for the assay of cysteine peptidases in complex mixtures.

    PubMed

    Semashko, Tatiana A; Vorotnikova, Elena A; Sharikova, Valeriya F; Vinokurov, Konstantin S; Smirnova, Yulia A; Dunaevsky, Yakov E; Belozersky, Mikhail A; Oppert, Brenda; Elpidina, Elena N; Filippova, Irina Y

    2014-03-15

    This study describes the design, synthesis, and use of selective peptide substrates for cysteine peptidases of the C1 papain family, important in many biological processes. The structure of the newly synthesized substrates is Glp-Xaa-Ala-Y (where Glp=pyroglutamyl; Xaa=Phe or Val; and Y=pNA [p-nitroanilide], AMC [4-amino-7-methylcoumaride], or AFC [4-amino-7-trifluoromethyl-coumaride]). Substrates were synthesized enzymatically to guarantee selectivity of the reaction and optical purity of the target compounds, simplifying the scheme of synthesis and isolation of products. The hydrolysis of the synthesized substrates was evaluated by C1 cysteine peptidases from different organisms and with different functions, including plant enzymes papain, bromelain, ficin, and mammalian lysosomal cathepsins B and L. The new substrates were selective for C1 cysteine peptidases and were not hydrolyzed by serine, aspartic, or metallo peptidases. We demonstrated an application of the selectivity of the synthesized substrates during the chromatographic separation of a multicomponent set of digestive peptidases from a beetle, Tenebrio molitor. Used in combination with the cysteine peptidase inhibitor E-64, these substrates were able to differentiate cysteine peptidases from peptidases of other classes in midgut extracts from T. molitor larvae and larvae of the genus Tribolium; thus, they are useful in the analysis of complex mixtures containing peptidases from different classes. Published by Elsevier Inc.

  6. High-throughput microplate technique for enzymatic hydrolysis of lignocellulosic biomass.

    PubMed

    Chundawat, Shishir P S; Balan, Venkatesh; Dale, Bruce E

    2008-04-15

    Several factors will influence the viability of a biochemical platform for manufacturing lignocellulosic based fuels and chemicals, for example, genetically engineering energy crops, reducing pre-treatment severity, and minimizing enzyme loading. Past research on biomass conversion has focused largely on acid based pre-treatment technologies that fractionate lignin and hemicellulose from cellulose. However, for alkaline based (e.g., AFEX) and other lower severity pre-treatments it becomes critical to co-hydrolyze cellulose and hemicellulose using an optimized enzyme cocktail. Lignocellulosics are appropriate substrates to assess hydrolytic activity of enzyme mixtures compared to conventional unrealistic substrates (e.g., filter paper, chromogenic, and fluorigenic compounds) for studying synergistic hydrolysis. However, there are few, if any, high-throughput lignocellulosic digestibility analytical platforms for optimizing biomass conversion. The 96-well Biomass Conversion Research Lab (BCRL) microplate method is a high-throughput assay to study digestibility of lignocellulosic biomass as a function of biomass composition, pre-treatment severity, and enzyme composition. The most suitable method for delivering milled biomass to the microplate was through multi-pipetting slurry suspensions. A rapid bio-enzymatic, spectrophotometric assay was used to determine fermentable sugars. The entire procedure was automated using a robotic pipetting workstation. Several parameters that affect hydrolysis in the microplate were studied and optimized (i.e., particle size reduction, slurry solids concentration, glucan loading, mass transfer issues, and time period for hydrolysis). The microplate method was optimized for crystalline cellulose (Avicel) and ammonia fiber expansion (AFEX) pre-treated corn stover. Copyright 2008 Wiley Periodicals, Inc.

  7. Rapid all-in-one three-step immunoassay for non-instrumental detection of ochratoxin A in high-coloured herbs and spices.

    PubMed

    Goryacheva, Irina Yu; De Saeger, Sarah; Nesterenko, Irina S; Eremin, Sergei A; Van Peteghem, Carlos

    2007-05-15

    A feasible three-step method for ochratoxin A (OTA) rapid detection was developed and applied for OTA screening in high-coloured matrices such as liquorice, ginger, nutmeg, black pepper, white pepper and Capsicum spp. spices at a control level of 10mugkg(-1). The method was based on the clean-up tandem immunoassay column and involved three steps: extract application, washing step and application of chromogenic substrate. A significant simplification of the assay was reached by using an additional frit with conjugate inside the clean-up tandem immunoassay column. The time for analysis was less than 10min, including 5min for colour development. Results were visually evaluated as colour development for negative result or no colour development for positive result. The method was coupled with a simple methanol-based extraction. A total of 27 samples were screened for OTA with the proposed method. It was shown that two samples of red pepper and one sample of liquorice, pili-pili, chilli and cayenne were contaminated with OTA above the control level at 10mugkg(-1), but none of tested ginger, nutmeg, black pepper and white pepper.

  8. Evaluation of Two Standard and Two Chromogenic Selective Media for Optimal Growth and Enumeration of Isolates of 16 Unique Bacillus Species.

    PubMed

    Kabir, M Shahjahan; Hsieh, Ying-Hsin; Simpson, Steven; Kerdahi, Khalil; Sulaiman, Irshad M

    2017-06-01

    The genus Bacillus is a group of gram-positive endospore-forming bacteria that can cause food poisoning and diarrheal illness in humans. A wide range of food products have been linked to foodborne outbreaks associated with these opportunistic pathogens. The U.S. Food and Drug Administration recommends (in their Bacteriological Analytical Manual) the use of Bacara or mannitol egg yolk polymyxin (MYP) agar plates and the most-probable-number (MPN) method for enumeration and confirmation of Bacillus cereus and related species isolated from foods, sporadic cases, outbreaks, and routine environmental surveillance samples. We performed a comparative analysis of two chromogenic media (Bacara and Brilliance) and two traditional media (MYP and polymyxin egg yolk mannitol bromothymol blue agar [PEMBA]) for the isolation and enumeration of 16 Bacillus species under modified growth conditions that included pH, temperature, and dilution factor. A total of 50 environmental, food, and American Type Culture Collection reference isolates from 16 distinct Bacillus species were evaluated. A food adulteration experiment also was carried out by artificially adulterating two baby food matrices with two isolates each of B. cereus and Bacillus thuringiensis . Our results clearly indicated that chromogenic plating media (Bacara and Brilliance) are better than conventional standard media (MYP and PEMBA) for the detection and enumeration of B. cereus in foods and other official regulatory samples. The comparison of the two chromogenic media also indicated that Brilliance medium to be more efficient and selective for the isolation of Bacillus.

  9. Evaluation of chromogenic media and seminested PCR in the identification of Candida species

    PubMed Central

    Daef, Enas; Moharram, Ahmed; Eldin, Salwa Seif; Elsherbiny, Nahla; Mohammed, Mona

    2014-01-01

    Identification of Candida cultured from various clinical specimens to the species level is increasingly necessary for clinical laboratories. Although sn PCR identifies the species within hours but its cost-effectiveness is to be considered. So there is always a need for media which help in the isolation and identification at the species level. The study aimed to evaluate the performance of different chromogenic media and to compare the effectiveness of the traditional phenotypic methods vs. seminested polymerase chain reaction (sn PCR) for identification of Candida species. One hundred and twenty seven Candida strains isolated from various clinical specimens were identified by conventional methods, four different chromogenic media and sn PCR. HiCrome Candida Differential and CHROMagar Candida media showed comparably high sensitivities and specificities in the identification of C. albicans, C. tropicalis, C. glabrata and C. krusei. CHROMagar Candida had an extra advantage of identifying all C. parapsilosis isolates. CHROMagar-Pal’s medium identified C. albicans, C. tropicalis and C. krusei with high sensitivities and specificities, but couldn’t identify C. glabrata or C. parapsilosis. It was the only medium that identified C. dubliniensis with a sensitivity and specificity of 100%. Biggy agar showed the least sensitivities and specificities. The overall concordance of the snPCR compared to the conventional tests including CHROMAgar Candida in the identification of Candida species was 97.5%. The use of CHROMAgar Candida medium is an easy and accurate method for presumptive identification of the most commonly encountered Candida spp. PMID:24948942

  10. Measuring factor IX activity of nonacog beta pegol with commercially available one-stage clotting and chromogenic assay kits: a two-center study.

    PubMed

    Bowyer, A E; Hillarp, A; Ezban, M; Persson, P; Kitchen, S

    2016-07-01

    Essentials Validated assays are required to precisely measure factor IX (FIX) activity in FIX products. N9-GP and two other FIX products were assessed in various coagulation assay systems at two sites. Large variations in FIX activity measurements were observed for N9-GP using some assays. One-stage and chromogenic assays accurately measuring FIX activity for N9-GP were identified. Background Measurement of factor IX activity (FIX:C) with activated partial thromboplastin time-based one-stage clotting assays is associated with a large degree of interlaboratory variation in samples containing glycoPEGylated recombinant FIX (rFIX), i.e. nonacog beta pegol (N9-GP). Validation and qualification of specific assays and conditions are necessary for the accurate assessment of FIX:C in samples containing N9-GP. Objectives To assess the accuracy of various one-stage clotting and chromogenic assays for measuring FIX:C in samples containing N9-GP as compared with samples containing rFIX or plasma-derived FIX (pdFIX) across two laboratory sites. Methods FIX:C, in severe hemophilia B plasma spiked with a range of concentrations (from very low, i.e. 0.03 IU mL(-1) , to high, i.e. 0.90 IU mL(-1) ) of N9-GP, rFIX (BeneFIX), and pdFIX (Mononine), was determined at two laboratory sites with 10 commercially available one-stage clotting assays and two chromogenic FIX:C assays. Assays were performed with a plasma calibrator and different analyzers. Results A high degree of variation in FIX:C measurement was observed for one-stage clotting assays for N9-GP as compared with rFIX or pdFIX. Acceptable N9-GP recovery was observed in the low-concentration to high-concentration samples tested with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. Similar patterns of FIX:C measurement were observed at both laboratory sites, with minor differences probably being attributable to the use of different analyzers. Conclusions These results suggest that, of the reagents tested, FIX:C in N9-GP-containing plasma samples can be most accurately measured with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. © 2016 International Society on Thrombosis and Haemostasis.

  11. Iron Determination in Meat Using Ferrozine Assay

    NASA Astrophysics Data System (ADS)

    Carpenter, Charles; Ward, Robert

    Chromogens are chemicals that react with compounds of interest and form colored products that can be quantified using spectroscopy. Several chromogens that selectively react with minerals are available. In this lab, ferrozine is used to measure ferrous iron in an ashed food sample. The relationship between the absorbance of the chromogen-mineral complex is described by Beer's Law; in this procedure, a standard curve is generated with a stock iron solution to quantify the mineral in beef samples.

  12. Inhibitory effect of chromogenic culture media on the growth of Rhodotorula: relevance to the diagnosis of Rhodotorula spp. infections.

    PubMed

    Bellanger, Anne-Pauline; Grenouillet, Frédéric; François, Nadine; Skana, Florence; Millon, Laurence

    2013-11-01

    With the increasing incidence and diverse etiologies of fungal infections, chromogenic yeast culture media are increasingly used for routine diagnosis. Rhodotorula species, which are characterized by the production of carotenoid pigments, are considered as emerging opportunistic pathogens. We recently diagnosed two fungemia due to Rhodotorula spp. and noticed that in both cases, the yeast failed to grow in subculture on the chromogenic yeast culture medium. This study was thus undertaken to investigate more thoroughly the ability (or inability) of Rhodotorula species to grow on different commercially available chromogenic media for yeast. Eighteen Rhodotorula spp. were checked for their ability to grow on four chromogenic yeast culture media: CHROMagar Candida (BD), Candi 4 Select (Biorad), Brilliance Candida (Oxoid), and Candida ID 2 (BioMerieux). All the Rhodotorula spp. strains grew on Brilliance and Candida ID 2, while only six isolates grew on Candi 4, and seven on CHROMagar. Two chromogenic yeast culture media showed a significant inhibitory effect on the growth of Rhodotorula species. As all Rhodotorula species are resistant to echinocandins and fluconazole, it is essential to isolate and identify these yeast quickly to initiate appropriate amphotericin B antifungal treatment as early as possible. The choice of media for routine use should take into account the ability of different media to allow all emerging fungal pathogens to grow. © 2013 APMIS. Published by John Wiley & Sons Ltd.

  13. A redox-mediated chromogenic reaction and application in immunoassay.

    PubMed

    Yu, Ru-Jia; Ma, Wei; Peng, Mao-Pan; Bai, Zhi-Shan; Long, Yi-Tao

    2016-08-31

    A novel redox-mediated chromogenic reaction was demonstrated based on the reaction between HAuCl4 and 2,2-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), which generate various color responses from red to green in the resulting solutions. Various redox substance could be used to mediate the reaction and trigger a distinct color response. We established a sensitive hydrogen peroxide colorimetric sensor based on the redox-mediated chromogenic reaction and depicted the application both in detection of enzyme and in an immunoassay. Combining the traditional chromogenic reagent with gold nanoparticles, our assay has the advantage in short response time (within three minutes), high sensitivity (10(-12) g mL(-1) for HBsAg) and stability. Copyright © 2016. Published by Elsevier B.V.

  14. SPECTROPHOTOMETRIC DETERMINATION OF CALCIUM WITH GLYOXAL BIS (2-HYDROXY- ANIL)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Florence, T.M.; Morgan, J.

    1961-03-01

    A selective method is described for the spectrophotometric determination of calcium using glyoxal bis(2hydroxy-anil) as the chromogenic agent. A comprehensive study of interferences and reagent variables was made. (auth)

  15. [Research on rapid and quantitative detection method for organophosphorus pesticide residue].

    PubMed

    Sun, Yuan-Xin; Chen, Bing-Tai; Yi, Sen; Sun, Ming

    2014-05-01

    The methods of physical-chemical inspection is adopted in the traditional pesticide residue detection, which require a lot of pretreatment processes, are time-consuming and complicated. In the present study, the authors take chlorpyrifos applied widely in the present agricultural field as the research object and propose a rapid and quantitative detection method for organophosphorus pesticide residues. At first, according to the chemical characteristics of chlorpyrifos and comprehensive chromogenic effect of several colorimetric reagents and secondary pollution, the pretreatment of the scheme of chromogenic reaction of chlorpyrifos with resorcin in a weak alkaline environment was determined. Secondly, by analyzing Uv-Vis spectrum data of chlorpyrifos samples whose content were between 0. 5 and 400 mg kg-1, it was confirmed that the characteristic information after the color reaction mainly was concentrated among 360 approximately 400 nm. Thirdly, the full spectrum forecasting model was established based on the partial least squares, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 995 6, standard deviation of calibration (RMSEC) was 2. 814 7 mg kg-1, and standard deviation of verification (RMSEP) was 8. 012 4 mg kg-1. Fourthly, the wavelengths whose center wavelength is 400 nm was extracted as characteristic region to build a forecasting model, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 999 3, standard deviation of calibration (RMSEC) was 2. 566 7 mg kg-1 , standard deviation of verification (RMSEP) was 4. 886 6 mg kg-1, respectively. At last, by analyzing the near infrared spectrum data of chlorpyrifos samples with contents between 0. 5 and 16 mg kg-1, the authors found that although the characteristics of the chromogenic functional group are not obvious, the change of absorption peaks of resorcin itself in the neighborhood of 5 200 cm-' happens. The above-mentioned experimental results show that the proposed method is effective and feasible for rapid and quantitative detection prediction for organophosphorus pesticide residues. In the method, the information in full spectrum especially UV-Vis spectrum is strengthened by chromogenic reaction of a colorimetric reagent, which provides a new way of rapid detection of pesticide residues for agricultural products in the future.

  16. Application of 2-Trichloromethylbenzimidazole in Analytical Chemistry: A Highly Selective Chromogenic Reagent for Thin-Layer Chromatography and Some Other Analytical Uses

    PubMed Central

    Konopski, Leszek; Kiełczewska, Anna

    2012-01-01

    2-Trichloromethylbenzimidazole (TCMB) was used as a chromogenic reagent in organic or inorganic analysis, mainly in thin-layer chromatography (TLC). In reactions of TCMB with some heteroaromatic nitrogen containing compounds, such as azines, azoles and benzazoles, a formation of high colored products occurred. For azines, the chromogenic reaction was highly regioselective, since the both adjacent α-positions versus the nitrogen atom(s) must not be substituted. A TLC method of detection was developed. Thirty azines, azoles, and benzazoles were detected at the detection limit 10 ng to 1 μg. This method was also applied for detection of heteroaromatic pesticides, and the attempts to construct active and passive dosimeters for nicotine were made. In a prechromatographic reaction of aromatic o-diamines with methyl trichloroacetimidate, TCMB or its derivatives were formed in situ. Followed by TLC and visualization in pyridine vapors, this procedure was applied for detection of o-phenylenediamine derivatives. The reaction product of TCMB and pyridine (LI Complex) was identified and fully characterized. Two different reaction mechanisms: with electron deficient basic heteroaromatic compounds, like pyridine, and with more acidic compounds, for example, pyrrole, were discussed. In aqueous solutions, the LI Complex may be also used as a new indicator for complexometric, adsorption and acid-base titration of inorganic compounds. PMID:22567563

  17. Production of β-Lactamase by Non-Streptomyces Actinomycetales

    PubMed Central

    Schwartz, Jeffrey L.; Schwartz, Surya P.

    1979-01-01

    Supernatants and whole cells from fermentation broths of Micromonospora, Nocardia, Oerskovia, and other genera of the Actinomycetales were examined for the presence of β-lactamase activity by using the chromogenic cephalosporin 87/312. Nearly 60% of the 250 isolates examined produced detectable levels of β-lactamase. All enzyme preparations were active over a range of pH values from 6.5 to 8.2, with maximum activity occurring between 7.0 and 7.8. The preparations varied in their stability at 60°C. An examination of selected enzyme preparations revealed a similarity between substrate specificities of the non-Streptomyces Actinomycetales and gram-negative-bacterial β-lactamases. PMID:311614

  18. Evaluation of the lactose Tergitol-7, m-Endo LES, Colilert 18, Readycult Coliforms 100, Water-Check-100, 3M Petrifilm EC and DryCult Coliform test methods for detection of total coliforms and Escherichia coli in water samples.

    PubMed

    Hörman, Ari; Hänninen, Marja-Liisa

    2006-10-01

    In this study we compared the reference membrane filtration (MF) lactose Tergitol-7 (LTTC) method ISO 9308-1:2000 with the MF m-Endo LES method SFS 3016:2001, the defined substrate chromogenic/fluorogenic Colilert 18, Readycult Coliforms and Water Check methods, and ready-made culture media, 3M Petrifilm EC and DryCult Coli methods for the detection of coliforms and Escherichia coli in various water samples. When the results of E. coli detection were compared between test methods, the highest agreement (both tests negative or positive) with the LTTC method was calculated for the m-Endo LES method (83.6%), followed by Colilert 18 (82.7%), Water-Check (81.8%) and Readycult (78.4%), whereas Petrifilm EC (70.6%) and DryCult Coli (68.9%) showed the weakest agreement. The m-Endo LES method was the only method showing no statistical difference in E. coli counts compared with the LTTC method, whereas the Colilert 18 and Readycult methods gave significantly higher counts for E. coli than the LTTC method. In general, those tests based on the analysis of a 1-ml sample (Petrifilm EC and DryCult Coli) showed weak sensitivity (39.5-52.5%) but high specificity (90.9-78.8%).

  19. Diagnosis of Asymptomatic Bacteriuria and Associated Risk Factors Among Pregnant Women in Mangalore, Karnataka, India

    PubMed Central

    Baby, Neha Maria; Kuruvilla, Thomas .S.; Machado, Santhosh

    2014-01-01

    Background: Asymptomatic bacteriuria (AB) is common inwomen and increases in prevalence with age or sexual activity. Prompt detection and treatment of this condition and associated factors decreases complications like acute pyleonephritis, intrauterine growth retardation and preterm labour. Chromogenic media is a versatile tool in rapid primary screening of the causative organisms considerably reducing daily routine workload. Aim: To determine the prevalence of AB among pregnant women in a tertiary care set-up and analyse the contributory risk factors, its effects on pregnancy and the role of chromogenic media in the laboratory diagnosis of these cases. Materials and Methods: Urine samples of all pregnant women attending pre-natal check-ups with no genitourinary complaints, history of fever or antibiotic intake were collected for Gram stain, culture and antibiotic sensitivity tests. A second urine specimen for culture and sensitivity testing was obtained from those with significant bacteriuria. The results were compared with patients showing negative urine cultures. Results: The overall prevalence of this clinical condition in our study was 13.2%. The significant isolates were Klebsiella pneumonia and E.coli and the most common risk factor was a previous history of urinary tract infection. The isolates were easily identified by using chromogenic agar ( HiCrome ) but colonies of uncommon pathogens like Acinetobacter and Streptococcus species appeared white and needed further identification. Conclusion: Screening of pregnant women for AB at first prenatal checkup helps analyse the associated factors and prevents its effects on pregnancy. The use of a chromogenic media can enhance reporting accuracy and will be an effective tool to monitor these cases routinely. PMID:25386490

  20. Optimization of a direct spectrophotometric method to investigate the kinetics and inhibition of sialidases

    PubMed Central

    2012-01-01

    Backgrounds Streptococcus pneumoniae expresses three distinct sialidases, NanA, NanB, and NanC, that are believed to be key virulence factors and thus, potential important drug targets. We previously reported that the three enzymes release different products from sialosides, but could share a common catalytic mechanism before the final step of product formation. However, the kinetic investigations of the three sialidases have not been systematically done thus far, due to the lack of an easy and steady measurement of sialidase reaction rate. Results In this work, we present further kinetic characterization of pneumococcal sialidases by using a direct spectrophotometric method with the chromogenic substrate p-nitrophenyl-N-acetylneuraminic acid (p-NP-Neu5Ac). Using our assay, the measured kinetic parameters of the three purified pneumococcal sialidase, NanA, NanB and NanC, were obtained and were in perfect agreement with the previously published data. The major advantage of this alternative method resides in the direct measurement of the released product, allowing to readily determine of initial reaction rates and record complete hydrolysis time courses. Conclusion We developed an accurate, fast and sensitive spectrophotometric method to investigate the kinetics of sialidase-catalyzed reactions. This fast, sensitive, inexpensive and accurate method could benefit the study of the kinetics and inhibition of sialidases in general. PMID:23031230

  1. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    PubMed

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  2. Chromogenic culture media or rapid immunochromatographic test: Which is better for detecting Klebsiella pneumoniae that produce OXA-48 and can they be used in blood and urine specimens.

    PubMed

    Genc, Ozlem; Aksu, Evrim

    2018-05-01

    Our goal was to compare a rapid test (OXA-48K-SeT) and four different chromogenic media (CHROMagar KPC, CHROMagar mSuperCARBA, ChromID Carba and ChromID OXA-48) for the detection of OXA-48 producing Klebsiella pneumoniae isolates and spiked urine/blood samples with these bacteria. In total 100 K.pneumoniae isolates, including 60 OXA-48 positive, 15 other carbapenemase producing, 15 Extended spectrum betalactamases (ESBL) positive and 10 carbapenem sensitive K.pneumoniae were included in the study. After all samples were inoculated into all chromogenic media, temocillin discs were placed onto the media. OXA-48K-SeT was studied according to the manufacturer's instructions and the lower detection limit was determined. Sensitivities and specificities of all chromogenic media and rapid test were detected as 100%. All of the OXA-48 producers were found resistant to temocillin on all chromogenic media. The lower detection limit of the rapid assay was determined as 10 6 in both direct bacterial samples and in spiked urine/blood samples. As a result, four chromogenic culture media and OXA-48 K-SeT can be used safely for detection of OXA-48 positive K.pneumoniae isolates. Although direct clinical specimens were not used, our study suggests that this media and OXA-48 K-SeT may be used in patient samples like blood and urine. Further studies are needed to assess this suggestion. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Performance of chromogenic media for Candida in rapid presumptive identification of Candida species from clinical materials

    PubMed Central

    Pravin Charles, M. V.; Kali, Arunava; Joseph, Noyal Mariya

    2015-01-01

    Background: In perspective of the worldwide increase in a number of immunocompromised patients, the need for identification of Candida species has become a major concern. The development of chromogenic differential media, introduced recently, facilitate rapid speciation. However, it can be employed for routine mycology workup only after an exhaustive evaluation of its benefit and cost effectiveness. This study was undertaken to evaluate the benefit and cost effectiveness of chromogenic media for speciation of Candida clinical isolates. Materials and Methods: Sputum samples of 382 patients were screened for the presence of Candida spp. by Gram stain and culture on sabouraud dextrose agar. Candida species were identified using Gram stain morphology, germ tube formation, cornmeal agar with Tween-80, sugar fermentation tests and morphology on HiCrome Candida differential agar. All the Candida isolates were inoculated on HiCrome Candida agar (HiMedia, Mumbai, India). Results: The sensitivity and specificity of HiCrome agar for identification of Candida albicans were 90% and 96.42%, respectively whereas sensitivity and specificity of carbohydrate fermentation test were 86.67% and 74.07%, respectively. Sensitivity and specificity values of HiCrome agar for detection of C. albicans, Candida parapsilosis and Candida glabrata were above 90%. Conclusions: We found HiCrome agar has high sensitivity and specificity comparable to that of the conventional method. In addition, use of this differential media could significantly cut down the turnaround time as well as cost of sample processing. PMID:26109791

  4. Comparative evaluation of three chromogenic media combined with broth enrichment and the real-time PCR-based Xpert MRSA assay for screening of methicillin-resistant Staphylococcus aureus in nasal swabs.

    PubMed

    Lee, Seungok; Park, Yeon-Joon; Park, Kang-Gyun; Jekarl, Dong Wook; Chae, Hyojin; Yoo, Jin-Kyung; Seo, Sin Won; Choi, Jung Eun; Lim, Jung Hye; Heo, Seon Mi; Seo, Ju Hee

    2013-07-01

    We evaluated the performance of three chromogenic media (Brilliance agar I [Oxoid, UK], Brilliance agar II [Oxoid], and ChromID MRSA [Biomérieux, France]) combined with broth enrichment and the Xpert MRSA assay for screening of methicillin-resistant Staphylococcus aureus (MRSA). We obtained 401 pairs of duplicate nasal swabs from 321 patients. One swab was suspended overnight in tryptic soy broth; 50-µL aliquots of suspension were inoculated on the three chromogenic media. Brilliance agar I and II were examined after 24 hr, and ChromID MRSA, after 24 and 48 hr. The paired swab was processed directly using real-time PCR-based Xpert MRSA assay. True positives, designated as MRSA growth in any of the culture media, were detected with the prevalence of 17% in our institution. We report the sensitivity, specificity, positive predictive value, and negative predictive value of MRSA growth as follows: 92.3%, 94.0%, 75.9%, and 98.4% in Brilliance agar I (24 hr); 92.7%, 97.9%, 90.0%, and 98.5% in Brilliance agar II (24 hr); 95.6%, 95.8%, 82.3%, and 99.1% in ChromID MRSA (24 hr); 100%, 92.5%, 73.1%, and 100% in ChromID MRSA (48 hr); 92.6%, 96.7%, 85.1%, and 98.5% in Xpert MRSA assay. The agreement between the enriched culture and Xpert MRSA assay was 96.0%. Three chromogenic culture media combined with enrichment and Xpert MRSA assay demonstrated similar capabilities in MRSA detection. The Xpert MRSA assay yielded results comparable to those of culture methods, saving 48-72 hr, thus facilitating earlier detection of MRSA in healthcare settings.

  5. Performance of Chromogenic Candida agar and CHROMagar Candida in recovery and presumptive identification of monofungal and polyfungal vaginal isolates.

    PubMed

    Ozcan, Kadri; Ilkit, Macit; Ates, Aylin; Turac-Bicer, Aygul; Demirhindi, Hakan

    2010-02-01

    Chromogenic Candida agar (OCCA) is a novel medium facilitating isolation and identification of Candida albicans, C. tropicalis, and C. krusei, as well as indicating polyfungal population in clinical samples. We compare the performance of OCCA, to CHROMagar Candida (CAC) and Sabouraud chloramphenicol agar (SCA). Vaginal swab samples from 392 women were simultaneously inoculated onto three study media. A total of 161 (41.1%) were found to be positive for fungi of which 140 (87%) were monofungal, and 21 (13%) polyfungal. One-hundred and fifty-seven samples (97.5%) were positive on CAC, 156 (96.9%) on OCCA, 148 (91.9%) on SCA and 144 (89.4%) samples were positive on all three media. The yeasts were identified by conventional methods including germ tube test, microscopic morphology on cornmeal-Tween 80 agar, and the commercial API 20C AUX. The 182 isolates were C. albicans (n = 104), C. glabrata (n = 51), C. krusei (n = 7), C. tropicalis (n = 5), C. famata (n = 3), C. kefyr (n = 3), C. zeylanoides (n = 3), C. colliculosa (n = 2), and other species of Candida (n = 4). Among the 21 polyfungal populations, 20 (95.2%) were detected in OCCA, 14 (66.7%) in CAC, and 13 (61.9%) in CAC and OCCA (P <0.05). Most polyfungal populations (47.6%) yielded C. albicans + C. glabrata. The efficiency of both chromogenic media for C. albicans was >or=92.9% at 72 h. OCCA is more efficient and reliable for rapidly identifying C. albicans and polyfungal populations than CAC. However, CAC is more efficient for identifying C. krusei and C. tropicalis. A chromogenic agar with a higher isolation rate of yeasts and better detection of polyfungal populations than SCA, is suggested as a medium of first choice when available.

  6. Performance of a New Chromogenic Medium, BBL CHROMagar MRSA II (BD), for Detection of Methicillin-Resistant Staphylococcus aureus in Screening Samples ▿

    PubMed Central

    Van Vaerenbergh, Kristien; Cartuyvels, Reinoud; Coppens, Guy; Frans, Johan; Van den Abeele, Anne-Marie; De Beenhouwer, Hans

    2010-01-01

    Two chromogenic media for the detection of MRSA were compared: BBL CHROMagar MRSA II (BD) and MRSA ID agar (bioMérieux). Following overnight nonselective enrichment, 1,919 screening samples were inoculated on both chromogenic agars. After 24 h, the sensitivities of both media were high and comparable. Both media showed an important decrease in specificity after 48 h of incubation (decreases of 8% for MRSA II and 10% for MRSA ID), but MRSA II was significantly more specific at both time points. PMID:20181915

  7. Application of chemical arrays in screening elastase inhibitors.

    PubMed

    Gao, Feng; Du, Guan-Hua

    2006-06-01

    Protein chip technology provides a new and useful tool for high-throughput screening of drugs because of its high performance and low sample consumption. In order to screen elastase inhibitors on a large scale, we designed a composite microarray integrating enzyme chip containing chemical arrays on glass slides to screen for enzymatic inhibitors. The composite microarray includes an active proteinase film, screened chemical arrays distributed on the film, and substrate microarrays to demonstrate change of color. The detection principle is that elastase hydrolyzes synthetic colorless substrates and turns them into yellow products. Because yellow is difficult to detect, bromochlorophenol blue (BPB) was added into substrate solutions to facilitate the detection process. After the enzyme had catalyzed reactions for 2 h, effects of samples on enzymatic activity could be determined by detecting color change of the spots. When chemical samples inhibited enzymatic activity, substrates were blue instead of yellow products. If the enzyme retained its activity, the yellow color of the products combined with blue of BPB to make the spots green. Chromogenic differences demonstrated whether chemicals inhibited enzymatic activity or not. In this assay, 11,680 compounds were screened, and two valuable chemical hits were identified, which demonstrates that this assay is effective, sensitive and applicable for high-throughput screening (HTS).

  8. Direct identification and recognition of yeast species from clinical material by using albicans ID and CHROMagar Candida plates.

    PubMed

    Baumgartner, C; Freydiere, A M; Gille, Y

    1996-02-01

    Two chromogenic media, Albicans ID and CHROMagar Candida agar plates, were compared with a reference medium, Sabouraud-chloramphenicol agar, and standard methods for the identification of yeast species. This study involved 951 clinical specimens. The detection rates for the two chromogenic media for polymicrobial specimens were 20% higher than that for the Sabouraud-chloramphenicol agar plates. The rates of identification of Candida albicans for Albicans ID and CHROMagar Candida agar plates were, respectively, 37.0 and 6.0% after 24 h of incubation and 93.6 and 92.2% after 72 h of incubation, with specificities of 99.8 and 100%. Furthermore, CHROMagar Candida plates identified 13 of 14 Candida tropicalis and 9 of 12 Candida krusei strains after 48 h of incubation.

  9. An in vivo, label-free quick assay for xylose transport in Escherichia coli.

    PubMed

    Chen, Tingjian; Zhang, Jingqing; Liang, Ling; Yang, Rong; Lin, Zhanglin

    2009-07-01

    Efficient use of xylose is necessary for economic production of biochemicals and biofuels from lignocellulosic materials. Current studies on xylose uptake for various microorganisms have been hampered by the lack of a facile assay for xylose transport. In this work, a rapid in vivo, label-free method for measuring xylose transport in Escherichia coli was developed by taking advantage of the Bacillus pumilus xylosidase (XynB), which cleaved a commercially available xylose analog, p-nitrophenyl-beta-d-xylopyranoside (pNPX), to release a chromogenic group, p-nitrophenol (pNP). XynB was expressed alone or in conjunction with a Zymomonas mobilis glucose facilitator protein (Glf) capable of transporting xylose. This XynB-mediated transport assay was demonstrated in test tubes and 96-well plates with submicromolar concentrations of pNPX. Kinetic inhibition experiments validated that pNPX and xylose were competitive substrates for the transport process, and the addition of glucose (20 g/L) in the culture medium clearly diminished the transmembrane transport of pNPX and, thus, mimicked its inhibitory action on xylose uptake. This method should be useful for engineering of the xylose transport process in E. coli, and similar assay schemes can be extended to other microorganisms.

  10. A Decade of Development of Chromogenic Culture Media for Clinical Microbiology in an Era of Molecular Diagnostics.

    PubMed

    Perry, John D

    2017-04-01

    In the last 25 years, chromogenic culture media have found widespread application in diagnostic clinical microbiology. In the last decade, the range of media available to clinical laboratories has expanded greatly, allowing specific detection of additional pathogens, including Pseudomonas aeruginosa, group B streptococci, Clostridium difficile, Campylobacter spp., and Yersinia enterocolitica. New media have also been developed to screen for pathogens with acquired antimicrobial resistance, including vancomycin-resistant enterococci, carbapenem-resistant Acinetobacter spp., and Enterobacteriaceae with extended-spectrum β-lactamases and carbapenemases. This review seeks to explore the utility of chromogenic media in clinical microbiology, with particular attention given to media that have been commercialized in the last decade. The impact of laboratory automation and complementary technologies such as matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is also assessed. Finally, the review also seeks to demarcate the role of chromogenic media in an era of molecular diagnostics. © Crown copyright 2017.

  11. A Decade of Development of Chromogenic Culture Media for Clinical Microbiology in an Era of Molecular Diagnostics

    PubMed Central

    2017-01-01

    SUMMARY In the last 25 years, chromogenic culture media have found widespread application in diagnostic clinical microbiology. In the last decade, the range of media available to clinical laboratories has expanded greatly, allowing specific detection of additional pathogens, including Pseudomonas aeruginosa, group B streptococci, Clostridium difficile, Campylobacter spp., and Yersinia enterocolitica. New media have also been developed to screen for pathogens with acquired antimicrobial resistance, including vancomycin-resistant enterococci, carbapenem-resistant Acinetobacter spp., and Enterobacteriaceae with extended-spectrum β-lactamases and carbapenemases. This review seeks to explore the utility of chromogenic media in clinical microbiology, with particular attention given to media that have been commercialized in the last decade. The impact of laboratory automation and complementary technologies such as matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) is also assessed. Finally, the review also seeks to demarcate the role of chromogenic media in an era of molecular diagnostics. PMID:28122803

  12. JC virus chromogenic in situ hybridization in brain biopsies from patients with and without PML.

    PubMed

    Procop, Gary W; Beck, Rose C; Pettay, James D; Kohn, Debra J; Tuohy, Marion J; Yen-Lieberman, Belinda; Prayson, Richard A; Tubbs, Raymond R

    2006-06-01

    Progressive multifocal leukoencephalopathy (PML) is a demyelinating disease of the central nervous system caused by the JC polyoma virus. Electron microscopy and immunohistochemistry are the traditional methods of confirming the presence of the virus in brain biopsies from these patients. We studied the brain biopsies from 7 patients with PML and 6 patients without PML with chromogenic in situ hybridization (CISH) for the JC polyoma virus using a commercially available probe. The biopsies from the patients with the PML cases were proven to contain the JC polyoma virus by traditional and molecular methods. The CISH findings were compared with the known state of infection. All (7/7) of the biopsies from patients with PML were positive for the presence of polyoma virus by CISH, whereas the biopsies from patients without PML were uniformly negative. CISH seems to be a useful tool for the detection of the JC virus in brain biopsies from patients with PML, and is more accessible because a commercial probe is available.

  13. tRNA-mediated labelling of proteins with biotin. A nonradioactive method for the detection of cell-free translation products.

    PubMed

    Kurzchalia, T V; Wiedmann, M; Breter, H; Zimmermann, W; Bauschke, E; Rapoport, T A

    1988-03-15

    We have developed a new method for the rapid and sensitive detection of cell-free translation products. Biotinylated lysine is incorporated into newly synthesized proteins by means of lysyl-tRNA that is modified in the epsilon-position. After electrophoresis in a dodecyl sulfate gel and blotting onto nitrocellulose, the translation products can be identified by probing with streptavidin and biotinylated alkaline phosphatase, followed by incubation with a chromogenic enzyme substrate. The non-radioactive labelling by biotin approaches in its sensitivity that obtained by radioactive amino acids. The products are absolutely stable and can be rapidly identified. The new method has been tested with different mRNAs in the cell-free translation systems of wheat germ and reticulocytes. Neither the interaction of secretory proteins with the signal recognition particle nor the in vitro translocation across the endoplasmic reticulum membrane or core glycosylation of nascent polypeptides are prevented by the incorporation of biotinylated lysine residues. The results indicate that both the ribosome and the endoplasmic reticulum membrane permit the passage of polypeptides carrying bulky groups attached to the amino acids (by atomic models it was estimated that the size of the side chain of lysine changes from approximately equal to 0.8 nm to approximately equal to 2 nm after modification.

  14. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    PubMed Central

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  15. Effect of wine inhibitors on the proteolytic activity of papain from Carica papaya L. latex.

    PubMed

    Benucci, Ilaria; Esti, Marco; Liburdi, Katia

    2015-01-01

    The influence of potential inhibitors naturally present in wine on the proteolytic activity of papain from Carica papaya latex was investigated to evaluate its applicability in white wine protein haze stabilization. Enzymatic activity was tested against a synthetic tripeptide chromogenic substrate in wine-like acidic medium that consisted of tartaric buffer (pH 3.2) supplemented with ethanol, free sulfur dioxide (SO2 ), grape skin and seed tannins within the average ranges of concentrations that are typical in wine. The diagnosis of inhibition type, performed with the graphical method, demonstrated that all of tested wine constituents were reversible inhibitors of papain. The strongest inhibition was exerted by free SO2 , which acted as a mixed-type inhibitor, similar to grape skin and seed tannins. Finally, when tested in table white wines, the catalytic activity of papain, even when if it was ascribable to the hyperbolic behavior of Michaelis-Menten equation, was determined to be strongly affected by free SO2 and total phenol level. © 2014 American Institute of Chemical Engineers.

  16. Enhanced Peroxidase-Like Performance of Gold Nanoparticles by Hot Electrons.

    PubMed

    Wang, Chen; Shi, Yi; Dan, Yuan-Yuan; Nie, Xing-Guo; Li, Jian; Xia, Xing-Hua

    2017-05-17

    Enzyme mimics have been widely used as alternatives to natural enzymes. However, the catalytic performances of enzyme mimics are often decreased due to different spatial structures or absence of functional groups compared to natural enzymes. Here, we report a highly efficient enzyme-like catalytic performance of gold nanoparticles (AuNPs) by visible-light stimulation. The enzyme-like reaction is evaluated by the catalytic reaction of AuNPs oxidizing a typical chromogenic substrate 3,3',5,5'-tetramethylbenzydine (TMB) with hydrogen peroxide as an oxidant. From investigations of the wavelength-dependent reaction rate, radical capture, hole-donor addition, and dark-field scattering spectroscopy experiments, it is revealed that the strong plasmonic absorption of AuNPs facilitates generation of hot electrons, which are transfered from AuNPs to the adsorbed reactant molecule, greatly promoting the catalytic performance of the enzyme-like catalytic reaction. The present work provides a simple method for improving the performance of enzyme mimics, which is expected to find further application in the field of plasmon-enhanced biocatalysis and biosensors. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Development and validation of a spectrophotometric method for the determination of macrolide antibiotics by using 2,4-dinitrophenylhydrazine.

    PubMed

    Abdelmageed, Osama H

    2007-01-01

    A simple, novel, sensitive, and specific spectrophotometric method was developed and validated for the determination of azithromycin (AZ), clarithromycin (CLA), and roxithromycin (ROX) in bulk powders and their dosage forms. The proposed method was based on the interaction of any of the cited drugs with 2,4-dinitrophenylhydrazine in the presence of an acid catalyst, followed by treatment with a methanolic solution of potassium hydroxide; an intensely colored chromogen was formed that was measured in dimethylformamide, as the diluting solvent, at 542-545, 523-526, and 539-542 nm for AZ, CLA, and ROX, respectively. All variables affecting the development of the measured chromogens were studied and optimized. Beer's law was obeyed in the concentration ranges of 5-40, 5-35, and 5-35 microg/mL for AZ, CLA, and ROX, respectively, with good correlation coefficients (0.9991-0.9999). The limits of detection for this method ranged from 0.77 to 1.47 microg/mL, and the relative standard deviations were 1.24-1.8%. The proposed method was applied successfully to the determination of the 3 drugs in pure bulk form, tablets, and suspensions without interference from commonly encountered additives. The results compared favorably with those of a previously reported method. The mechanism of the reaction was also studied.

  18. An association between Schistosoma mansoni worms and an enzymatically-active protease/peptidase in mouse blood.

    PubMed

    Darani, H Y; Doenhoff, M J

    2008-04-01

    An enzyme found previously in extracts of adult Schistosoma mansoni worms, that hydrolysed the chromogenic substrate N-acetyl-DL-phenylalanine beta-naphthyl-ester, has here been further investigated and characterized. Evidence that the molecule found in the parasite was antigenically and enzymatically homologous with a constituent of normal mouse plasma has been consolidated using a monospecific serum in immunoelectrophoresis and Western immunoblotting. The molecular size of the enzyme was found to be approximately 70 kDa and it was inhibited by a serine protease inhibitor, but not by inhibitors of other classes of protease. The enzymatic activity found in normal mouse serum was also found in normal rat serum, but not in sera from several other mammalian species.

  19. Quantitative image analysis of immunohistochemical stains using a CMYK color model

    PubMed Central

    Pham, Nhu-An; Morrison, Andrew; Schwock, Joerg; Aviel-Ronen, Sarit; Iakovlev, Vladimir; Tsao, Ming-Sound; Ho, James; Hedley, David W

    2007-01-01

    Background Computer image analysis techniques have decreased effects of observer biases, and increased the sensitivity and the throughput of immunohistochemistry (IHC) as a tissue-based procedure for the evaluation of diseases. Methods We adapted a Cyan/Magenta/Yellow/Key (CMYK) model for automated computer image analysis to quantify IHC stains in hematoxylin counterstained histological sections. Results The spectral characteristics of the chromogens AEC, DAB and NovaRed as well as the counterstain hematoxylin were first determined using CMYK, Red/Green/Blue (RGB), normalized RGB and Hue/Saturation/Lightness (HSL) color models. The contrast of chromogen intensities on a 0–255 scale (24-bit image file) as well as compared to the hematoxylin counterstain was greatest using the Yellow channel of a CMYK color model, suggesting an improved sensitivity for IHC evaluation compared to other color models. An increase in activated STAT3 levels due to growth factor stimulation, quantified using the Yellow channel image analysis was associated with an increase detected by Western blotting. Two clinical image data sets were used to compare the Yellow channel automated method with observer-dependent methods. First, a quantification of DAB-labeled carbonic anhydrase IX hypoxia marker in 414 sections obtained from 138 biopsies of cervical carcinoma showed strong association between Yellow channel and positive color selection results. Second, a linear relationship was also demonstrated between Yellow intensity and visual scoring for NovaRed-labeled epidermal growth factor receptor in 256 non-small cell lung cancer biopsies. Conclusion The Yellow channel image analysis method based on a CMYK color model is independent of observer biases for threshold and positive color selection, applicable to different chromogens, tolerant of hematoxylin, sensitive to small changes in IHC intensity and is applicable to simple automation procedures. These characteristics are advantageous for both basic as well as clinical research in an unbiased, reproducible and high throughput evaluation of IHC intensity. PMID:17326824

  20. Comparative evaluation of six chromogenic media for presumptive yeast identification.

    PubMed

    Vecchione, Alessandra; Florio, Walter; Celandroni, Francesco; Barnini, Simona; Lupetti, Antonella; Ghelardi, Emilia

    2017-12-01

    The present study was undertaken to evaluate the discrimination ability of six chromogenic media in presumptive yeast identification. We analysed 108 clinical isolates and reference strains belonging to eight different species: Candida albicans , Candida dubliniensis , Candida tropicalis , Candida krusei , Candida glabrata , Candida parapsilosis , Candida lusitaniae and Trichosporon mucoides . C. albicans , C. tropicalis and C. krusei could be distinguished from one another in all the tested chromogenic media, as predicted by the manufacturers. In addition, C. albicans could be distinguished from C. dubliniensis on BBL CHROMagar Candida, Kima CHROMagar Candida and Brilliance Candida, and C. parapsilosis could be identified on CHROMATIC Candida agar, CHROMOGENIC Candida agar, and Brilliance Candida agar. Brilliance Candida provided the widest discrimination ability, being able to discriminate five out of the seven Candida species tested. Interestingly, C. tropicalis and C. krusei could be already distinguished from each other after 24 hours of incubation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Pathology consultation on anticoagulation monitoring: factor X-related assays.

    PubMed

    Wool, Geoffrey D; Lu, Chuanyi M

    2013-11-01

    To review various anticoagulation therapies and related laboratory monitoring issues, with a focus on factor X-related chromogenic assays. A case-based approach is used to review pertinent published literatures and product inserts of anticoagulation drugs and to look back on clinical use of factor X-related chromogenic assays. The number of anticoagulants available to clinicians has increased greatly in the past decade. Whether and how these anticoagulants should be monitored are areas of uncertainty for clinicians, which can lead to misuse of laboratory assays and suboptimal patient management. Factor X-related assays are of particular concern because of the similar and often confusing test names. Based on a common clinical case scenario and literature review regarding anticoagulant monitoring, an up-to-date discussion and review of the various factor X-related assays are provided, focusing on the differences in test designs and clinical utilities between the chromogenic anti-Xa and chromogenic factor X activity assays. Anticoagulation therapy and related laboratory monitoring are rapidly evolving areas of clinical practices. A good knowledge of relevant laboratory assays and their clinical applications is necessary to help optimize patient care.

  2. An investigation into the use of SDS-PAGE of cell surface extracts and proteolytic activity to differentiate Prevotella nigrescens and Prevotella intermedia.

    PubMed

    Cookson, A L; Wray, A; Handley, P S; Jacob, A E

    1996-02-15

    By comparison of the cell surface proteins derived from the outer membrane and fibrils from 14 Prevotella intermedia and 19 Prevotella nigrescens strains using SDS and analysed by SDS-PAGE, it was possible to distinguish the two species. A polypeptide of approx. 21 kDa distinguished P. intermedia strains, whereas two polypeptides of approx. 18 and 22 kDa could be used to identify P. nigrescens strains. Four other human oral black pigmented bacterial species (Porphyromonas gingivalis, Prevotella denticola, Prevotella loescheii and Prevotella melaninogenica) did not have the 18-, 21- or 22-kDa polypeptides shown by P. intermedia or P. nigrescens. The cell-associated proteolytic activity of eight strains of P. intermedia, 14 strains of P. nigrescens and one strain of P. gingivalis (W50) was assessed using four chromogenic substrates. The hydrolysis of the substrate GPPNA (indicative of dipeptidyl peptidase IV-like activity) and SAAPPNA (elastase-like activity) by P. intermedia strains varied from 32 to 114 units and 0.5 to 12.6 units of activity respectively, where one unit was defined as the amount of protease enzyme catalysing the formation of 1 nmol of p-nitroaniline under experimental conditions. 37.5% (3 of 8) of P. intermedia strains hydrolysed SAAPPNA (chymotrypsin-like enzyme activity) with activities of between 7 and 12 units. The hydrolysis of GPPNA and SAAAPNA by P. nigrescens strains was 32-149 and 3-16 units, respectively. 57% (8 of 14) of P. nigrescens strains hydrolysed SAAPPPNA with activities ranging from 3 to 8 units. None of the P. intermedia or P. nigrescens strains examined were found to have trypsin-like enzyme activity (BAPNA hydrolysis). The GPPNA and SAAAPNA hydrolytic activity associated with the proteases from Porphyromonas gingivalis W50 was at least twice that of P. intermedia and P. nigrescens strains. The similar peptidase activities of P. intermedia and P. nigrescens against chromogenic substrates cannot be used to differentiate the species, but SDS-PAGE of cell surface protein extracts allowed unambiguous speciation between P. intermedia and P. nigrescens. This simple technique of cell surface protein analysis can be performed in most laboratories and offers a convenient way by which to differentiate the two species.

  3. Streptococcus thermophilus Cell Wall-Anchored Proteinase: Release, Purification, and Biochemical and Genetic Characterization

    PubMed Central

    Fernandez-Espla, María Dolores; Garault, Peggy; Monnet, Véronique; Rul, Françoise

    2000-01-01

    Streptococcus thermophilus CNRZ 385 expresses a cell envelope proteinase (PrtS), which is characterized in the present work, both at the biochemical and genetic levels. Since PrtS is resistant to most classical methods of extraction from the cell envelopes, we developed a three-step process based on loosening of the cell wall by cultivation of the cells in the presence of glycine (20 mM), mechanical disruption (with alumina powder), and enzymatic treatment (lysozyme). The pure enzyme is a serine proteinase highly activated by Ca2+ ions. Its activity was optimal at 37°C and pH 7.5 with acetyl-Ala-Ala-Pro-Phe-paranitroanilide as substrate. The study of the hydrolysis of the chromogenic and casein substrates indicated that PrtS presented an intermediate specificity between the most divergent types of cell envelope proteinases from lactococci, known as the PI and PIII types. This result was confirmed by the sequence determination of the regions involved in substrate specificity, which were a mix between those of PI and PIII types, and also had unique residues. Sequence analysis of the PrtS encoding gene revealed that PrtS is a member of the subtilase family. It is a multidomain protein which is maturated and tightly anchored to the cell wall via a mechanism involving an LPXTG motif. PrtS bears similarities to cell envelope proteinases from pyogenic streptococci (C5a peptidase and cell surface proteinase) and lactic acid bacteria (PrtP, PrtH, and PrtB). The highest homologies were found with streptococcal proteinases which lack, as PrtS, one domain (the B domain) present in cell envelope proteinases from all other lactic acid bacteria. PMID:11055922

  4. Activity-Dependent Enzymatic Assay for the Detection of Toluene-Oxidizing Bacteria Capable of Trichloroethylene Degradation

    NASA Astrophysics Data System (ADS)

    Kauffman, M. E.; Kauffman, M. E.; Keener, W. K.; Watwood, M. E.; Lehman, R. M.

    2001-12-01

    Toluene-oxidizing bacteria produce enzymes that cometabolically degrade trichloroethylene (TCE). These inducible enzymes are produced only in the presence of certain aromatic substrates such as toluene or phenol. Recent laboratory studies have utilized analog chemical substrates to identify production of bacterial enzymes capable of degrading trichloroethylene. These analog substrates produce chromogenic and/or fluorescent products when biotransformed by the enzymes of interest. In this study, 3-hydroxyphenylacetylene (3-HPA) was identified as an activity-dependent enzymatic probe for the detection of three of the four known toluene oxygenase enzymes capable of TCE degradation. Laboratory studies were conducted using pure cultures of Burkholderia cepacia G4, Burkholderia pickettii PKO1, and Pseudomonas putida F1. Cell cultures grown on lactate (non-enzyme inducing) or lactate and toluene (inducing) were trapped trapped on black polycarbonate filters, exposed to 3-HPA, and examined for fluorescence using an epifluorescent microscope. Additionally, B. cepacia G4 cells were grown under the same conditions, but in the presence of mineral and basalt specimens to allow for bacterial attachment. The specimens were then exposed to 3-HPA and examined under an epifluorescent microscope. Our results demonstrate that cells induced for the production of oxygenase enzymes, both unattached and attached, are able to transform 3-HPA to a fluorescent product, although cells attached to geologic materials, such as basalt, take substantially longer to transform the probe. Cells grown under non-inducing conditions do not transform the probe, regardless of their attachment status. Additionally, well water samples taken from a TCE-contaminated aquifer were successfully assayed using the 3-HPA enzymatic probe. The development of this enzyme activity-dependent enzymatic assay provides a fast and reliable method to assess the potential for TCE and aromatic contaminant bioremediation.

  5. Coagulase-negative staphylococci from non-mastitic bovine mammary gland: characterization of Staphylococcus chromogenes and Staphylococcus haemolyticus by antibiotic susceptibility testing and pulsed-field gel electrophoresis.

    PubMed

    Pate, Mateja; Zdovc, Irena; Avberšek, Jana; Ocepek, Matjaž; Pengov, Andrej; Podpečan, Ožbalt

    2012-05-01

    During routine microbiological examination of milk samples from dairy cows without clinical signs of mastitis, quarter milk samples of 231 dairy cows from 12 herds were investigated for the presence of coagulase-negative staphylococci (CNS). The isolates were identified on the basis of colony morphology, Gram staining, catalase and coagulase test and the commercial kit, API Staph. CNS was detected in 29% (67/231) of the cows. A total of seven CNS species were identified with the most prevalent being Staphylococcus (Staph.) chromogenes (30%) and Staph. haemolyticus (28·8%), followed by Staph. simulans (11·2%), Staph. xylosus (11·2%), Staph. epidermidis (7·5%), Staph. hyicus (6·3%) and Staph. sciuri (5%). The predominant species, Staph. chromogenes and Staph. haemolyticus, were further characterized by antibiotic susceptibility testing using the agar disc diffusion method (Kirby-Bauer) and by pulsed-field gel electrophoresis (PFGE). Considerable resistance to ampicillin and penicillin was observed in both species. Isolates with identical or highly similar PFGE profiles were detected at the herd level despite a marked heterogeneity seen for both species. On the basis of somatic cell count, absence of clinical signs of inflammation and heterogeneity of genotypes, we assume that CNS isolated in this study could not be considered as important causative agents of the bovine mammary gland inflammation.

  6. Effect of platelet-derived β-thromboglobulins on coagulation.

    PubMed

    Egan, Karl; van Geffen, Johanna P; Ma, Hui; Kevane, Barry; Lennon, Aine; Allen, Seamus; Neary, Elaine; Parsons, Martin; Maguire, Patricia; Wynne, Kieran; O' Kennedy, Richard; Heemskerk, Johan W M; Áinle, Fionnuala Ní

    2017-06-01

    β-thromboglobulins are derived from the cleavage of the CXC chemokine platelet basic protein and are released in high concentrations by activated platelets. Platelet-derived β-thromboglobulins (βTG) share 70% homology with platelet factor 4 (PF4), another CXC chemokine released by activated platelets. PF4 modulates coagulation by inhibiting heparin-antithrombin interactions, promoting protein C activation, and attenuating the activity of activated protein C. In contrast, the effect of βTG on coagulation is unknown. Clotting times, thrombin generation, chromogenic clotting factor assays, and surface plasmon resonance (SPR) were used to assess the effect of purified βTG on coagulation. In normal pooled plasma, βTG shortened the lagtime and time to peak thrombin generation of tissue factor (TF)-dependent and TF-independent thrombin generation. In factor VIII and factor IX-deficient plasmas, βTG induced thrombin generation in the absence of a TF stimulus and in the presence of anti-TF and factor VIIa inhibitory antibodies. The procoagulant effect was not observed when thrombin generation was independent of factor X activation (supplementation of factor X-deficient plasma with factor Xa). Cleavage of a factor Xa-specific chromogenic substrate was observed when βTG was incubated with factor X, suggesting a direct interaction between βTG and factor X. Using SPR, βTG were found to bind to immobilised factor X in a dose dependent manner. βTG modulate coagulation in vitro via an interaction with factor X. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Establishment of the 2nd Korean national biological reference standard for blood coagulation factor VIII:C concentrate.

    PubMed

    Lee, Naery; Seo, Ji Suk; Kim, Jae Ok; Ban, Sang Ja

    2017-05-01

    Since the 1st Korean national biological reference standard for factor (F)VIII concentrate, established in 2001, has shown declining potency, we conducted this study to replace this standard with a 2nd Korean national biological reference standard for blood coagulation FVIII concentrate. The candidate materials for the 2nd standard were prepared in 8000 vials with 10 IU/ml of target potency, according to the approved manufacturing process of blood coagulation Factor VIII:C Monoclonal Antibody-purified, Freeze-dried Human Blood Coagulation Factor VIII:C. Potency was evaluated by one-stage clotting and chromogenic methods and the stability was confirmed to meet the specifications during a period of 73 months. Since the potencies obtained by the two methods differed significantly (P < 0.015), the values were determined separately according to the geometric means (8.9 and 7.4 IU/vial, respectively). The geometric coefficients of interlaboratory variability were 3.4% and 7.6% by the one-stage clotting and chromogenic assays, respectively. Copyright © 2017 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  8. Recombinant to modified factor VIII and factor IX - chromogenic and one-stage assays issues.

    PubMed

    Kitchen, S; Kershaw, G; Tiefenbacher, S

    2016-07-01

    The recent development of modified recombinant factor VIII (FVIII) and factor IX (FIX) therapeutic products with extended half-lives will create challenges for the haemostasis laboratory in obtaining recovery estimates of these products in clinical samples using existing assays. The new long-acting therapeutic concentrates contain molecular modifications of Fc fusion, site-specific of polyethylene glycol or albumin fusion. The optimum methods for monitoring each new product will need to be assessed individually and laboratories should select an assay which gives similar results to the assay used to assign potency to the product in question. For some extended half-life FVIII and FIX products some one stage assays are entirely unsuitable for monitoring purposes. For most products and assay reagents studied so far, and reviewed in this manuscript, chromogenic FVIII or FIX assays can be safely used with conventional plasma standards. If one stage assays are used then they should be performed using carefully selected reagents/methods which have been shown to recover activity close to the labelled potency for the specific product being monitored. © 2016 John Wiley & Sons Ltd.

  9. Identification of a Saccharomyces cerevisiae glucosidase that hydrolyzes flavonoid glucosides.

    PubMed

    Schmidt, Sabine; Rainieri, Sandra; Witte, Simone; Matern, Ulrich; Martens, Stefan

    2011-03-01

    Baker's yeast (Saccharomyces cerevisiae) whole-cell bioconversions of naringenin 7-O-β-glucoside revealed considerable β-glucosidase activity, which impairs any strategy to generate or modify flavonoid glucosides in yeast transformants. Up to 10 putative glycoside hydrolases annotated in the S. cerevisiae genome database were overexpressed with His tags in yeast cells. Examination of these recombinant, partially purified polypeptides for hydrolytic activity with synthetic chromogenic α- or β-glucosides identified three efficient β-glucosidases (EXG1, SPR1, and YIR007W), which were further assayed with natural flavonoid β-glucoside substrates and product verification by thin-layer chromatography (TLC) or high-performance liquid chromatography (HPLC). Preferential hydrolysis of 7- or 4'-O-glucosides of isoflavones, flavonols, flavones, and flavanones was observed in vitro with all three glucosidases, while anthocyanins were also accepted as substrates. The glucosidase activities of EXG1 and SPR1 were completely abolished by Val168Tyr mutation, which confirmed the relevance of this residue, as reported for other glucosidases. Most importantly, biotransformation experiments with knockout yeast strains revealed that only EXG1 knockout strains lost the capability to hydrolyze flavonoid glucosides.

  10. Fast determination of royal jelly freshness by a chromogenic reaction.

    PubMed

    Zheng, Huo-Qing; Wei, Wen-Ting; Wu, Li-Ming; Hu, Fu-Liang; Dietemann, Vincent

    2012-06-01

    Royal jelly is one of the most important products of honeybees. Given its role in development of bee brood into fertile individuals of the royal caste it is also used in health products for human consumption. Royal jelly spoils and loses its health-promoting properties depending on storage duration and conditions. To ensure product quality before selling, it is therefore necessary to assess royal jelly freshness. Many indexes of freshness have been suggested, but they all lack reliability or require complex and time-consuming analyses. Here we describe a method to detect royal jelly freshness based on a chromogenic reaction between royal jelly and HCl. We demonstrate that analyses based on color parameters allow for the discrimination of royal jelly samples based on the duration of their storage. Color parameters of royal jelly stored at -18 and 4 °C for 28 d remained comparable to that of fresh samples, which supports the reliability of the method. The method of freshness determination described is practical, cheap, and fast and can thus be used in real-time when trading royal jelly. The method developed can be used to assess royal jelly freshness. It is practical, cheap, and fast and can thus be used in real-time when trading royal jelly. © 2012 Institute of Food Technologists®

  11. Gel-based immunotest for simultaneous detection of 2,4,6-trichlorophenol and ochratoxin A in red wine.

    PubMed

    Beloglazova, N V; Goryacheva, I Yu; Rusanova, T Yu; Yurasov, N A; Galve, R; Marco, M-P; De Saeger, S

    2010-07-05

    A new rapid method which allows simultaneous one step detection of two analytes of different nature (2,4,6,-trichlorophenol (TCP) and ochratoxin A (OTA)) in red wine was developed. It was based on a column test with three separate immunolayers: two test layers and one control layer. Each layer consisted of sepharose gel with immobilized anti-OTA (OTA test layer), anti-TCP (TCP test layer) or anti-HRP (control layer) antibodies. Analytes bind to the antibodies in the corresponding test layer while sample flows through the column. Then a mixture of OTA-HRP and TCP-HRP in appropriate dilutions was used, followed by the application of chromogenic substrate. Colour development of the test layer occurred when the corresponding analyte was absent in the sample. HRP-conjugates bound to anti-HRP antibody in the control layer independently of presence or absence of analytes and a blue colour developed in the control layer. Cut-off values for both analytes were 2 microg L(-1). The described method was applied to the simultaneous detection of TCP and OTA in wine samples. To screen the analytes in red wine samples, clean-up columns were used for sample pre-treatment in combination with the test column. Results were confirmed by chromatographic methods. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Selective sensing of submicromolar iron(III) with 3,3‧,5,5‧-tetramethylbenzidine as a chromogenic probe

    NASA Astrophysics Data System (ADS)

    Zhang, Lufeng; Du, Jianxiu

    2016-04-01

    The development of highly selective and sensitive method for iron(III) detection is of great importance both from human health as well as environmental point of view. We herein reported a simple, selective and sensitive colorimetric method for the detection of Fe(III) at submicromolar level with 3,3,‧5,5‧-tetramethylbenzidine (TMB) as a chromogenic probe. It was observed that Fe(III) could directly oxidize TMB to form a blue solution without adding any extra oxidants. The reaction has a stoichiometric ratio of 1:1 (Fe(III)/TMB) as determined by a molar ratio method. The resultant color change can be perceived by the naked eye or monitored the absorbance change at 652 nm. The method allowed the measurement of Fe(III) in the range 1.0 × 10- 7-1.5 × 10- 4 mol L- 1 with a detection limit of 5.5 × 10- 8 mol L- 1. The relative standard deviation was 0.9% for eleven replicate measurements of 2.5 × 10- 5 mol L- 1 Fe(III) solution. The chemistry showed high selectivity for Fe(III) in contrast to other common cation ions. The practically of the method was evaluated by the determination of Fe in milk samples; good consistency was obtained between the results of this method and atomic absorption spectrophotometry as indicated by statistical analysis.

  13. A Dispersion-Dominated Chromogenic Strategy for Colorimetric Sensing of Glutathione at the Nanomolar Level Using Gold Nanoparticles.

    PubMed

    Xianyu, Yunlei; Xie, Yangzhouyun; Wang, Nuoxin; Wang, Zhuo; Jiang, Xingyu

    2015-11-04

    A dispersion-dominated chromogenic strategy for glutathione sensing is developed. Glutathione prevents the aggregation of arginine-modified gold nanoparticles via mercury-thiol interaction, which allows for glutathione sensing at the nanomolar level (10.9 × 10(-9) m) with facile operation and naked-eye readout. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Some structural features of the teichuronic acid of Bacillus licheniformis N.C.T.C. 6346 cell walls

    PubMed Central

    Hughes, R. C.; Thurman, P. F.

    1970-01-01

    A teichuronic acid, containing glucuronic acid and N-acetylgalactosamine, was purified from acid extracts of Bacillus licheniformis 6346 cell walls as described by Janczura, Perkins & Rogers (1961). After reduction of the carboxyl function of glucuronic acid residues in the polysaccharide the reduced polymer contains equimolar amounts of N-acetylgalactosamine and glucose. Methylation of the reduced polysaccharide by the Hakamori (1964) technique showed the glucose residues to be substituted on C-4. A disaccharide, 3-O-glucuronosylgalactosamine, was isolated from partial acid hydrolysates of teichuronic acid. After N-acetylation the disaccharide produces chromogen readily on heating at pH7, in agreement with C-3 substitution of the reducing N-acetylamino sugar. Teichuronic acid also produces chromogen under the same conditions, with concurrent elimination of a modified polysaccharide from C-3 of reducing terminal N-acetylgalactosamine residues of the teichuronic acid chains. The number-average chain lengths of several preparations of teichuronic acid were estimated from the amounts of chromogen produced in comparison with the N-acetylated disaccharide. The values obtained are in good agreement with the weight-average molecular weight determined by ultracentrifugal analysis. The reducing terminals of teichuronic acid are shown to be exclusively N-acetylgalactosamine by reduction with sodium boro[3H]hydride. The number-average chain lengths of the teichuronic acid preparations were estimated by the extent of in corporation of tritium and are in agreement with values obtained by the other methods. PMID:5419741

  15. Performance of chromogenic media for Candida in rapid presumptive identification of Candida species from clinical materials.

    PubMed

    Pravin Charles, M V; Kali, Arunava; Joseph, Noyal Mariya

    2015-06-01

    In perspective of the worldwide increase in a number of immunocompromised patients, the need for identification of Candida species has become a major concern. The development of chromogenic differential media, introduced recently, facilitate rapid speciation. However, it can be employed for routine mycology workup only after an exhaustive evaluation of its benefit and cost effectiveness. This study was undertaken to evaluate the benefit and cost effectiveness of chromogenic media for speciation of Candida clinical isolates. Sputum samples of 382 patients were screened for the presence of Candida spp. by Gram stain and culture on sabouraud dextrose agar. Candida species were identified using Gram stain morphology, germ tube formation, cornmeal agar with Tween-80, sugar fermentation tests and morphology on HiCrome Candida differential agar. All the Candida isolates were inoculated on HiCrome Candida agar (HiMedia, Mumbai, India). The sensitivity and specificity of HiCrome agar for identification of Candida albicans were 90% and 96.42%, respectively whereas sensitivity and specificity of carbohydrate fermentation test were 86.67% and 74.07%, respectively. Sensitivity and specificity values of HiCrome agar for detection of C. albicans, Candida parapsilosis and Candida glabrata were above 90%. We found HiCrome agar has high sensitivity and specificity comparable to that of the conventional method. In addition, use of this differential media could significantly cut down the turnaround time as well as cost of sample processing.

  16. Modelling the Costs and Effects of Selective and Universal Hospital Admission Screening for Methicillin-Resistant Staphylococcus aureus

    PubMed Central

    Hubben, Gijs; Bootsma, Martin; Luteijn, Michiel; Glynn, Diarmuid; Bishai, David

    2011-01-01

    Background Screening at hospital admission for carriage of methicillin-resistant Staphylococcus aureus (MRSA) has been proposed as a strategy to reduce nosocomial infections. The objective of this study was to determine the long-term costs and health benefits of selective and universal screening for MRSA at hospital admission, using both PCR-based and chromogenic media-based tests in various settings. Methodology/Principal Findings A simulation model of MRSA transmission was used to determine costs and effects over 15 years from a US healthcare perspective. We compared admission screening together with isolation of identified carriers against a baseline policy without screening or isolation. Strategies included selective screening of high risk patients or universal admission screening, with PCR-based or chromogenic media-based tests, in medium (5%) or high nosocomial prevalence (15%) settings. The costs of screening and isolation per averted MRSA infection were lowest using selective chromogenic-based screening in high and medium prevalence settings, at $4,100 and $10,300, respectively. Replacing the chromogenic-based test with a PCR-based test costs $13,000 and $36,200 per additional infection averted, and subsequent extension to universal screening with PCR would cost $131,000 and $232,700 per additional infection averted, in high and medium prevalence settings respectively. Assuming $17,645 benefit per infection averted, the most cost-saving strategies in high and medium prevalence settings were selective screening with PCR and selective screening with chromogenic, respectively. Conclusions/Significance Admission screening costs $4,100–$21,200 per infection averted, depending on strategy and setting. Including financial benefits from averted infections, screening could well be cost saving. PMID:21483492

  17. Chromogenic switchable glazing: Towards the development of the smart window

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lampert, C.M.

    1995-06-01

    The science and technology of chromogenic materials for switchable glazings in building applications is discussed. These glazings can be used for dynamic control of solar and visible energy. Currently many researchers and engineers are involved with the development of products in this field. A summary of activities in Japan, Europe, Australia, USA and Canada is made. The activities of the International Energy Agency are included. Both non-electrically activated and electrically activated glazings are discussed. Technologies covered in the first category are photochromics, and thermochromics and thermotropics. A discussion of electrically activated chromogenic glazings includes dispersed liquid crystals, dispersed particles andmore » electrochromics. A selection of device structures and performance characteristics are compared. A discussion of transparent conductors is presented. Technical issues concerning large-area development of smart windows are discussed.« less

  18. Magnetic bead-based enzyme-chromogenic substrate system for ultrasensitive colorimetric immunoassay accompanying cascade reaction for enzymatic formation of squaric acid-iron(III) chelate.

    PubMed

    Lai, Wenqiang; Tang, Dianping; Zhuang, Junyang; Chen, Guonan; Yang, Huanghao

    2014-05-20

    This work reports on a simple and feasible colorimetric immunoassay with signal amplification for sensitive determination of prostate-specific antigen (PSA, used as a model) at an ultralow concentration by using a new enzyme-chromogenic substrate system. We discovered that glucose oxidase (GOx), the enzyme broadly used in enzyme-linked immunosorbent assay (ELISA), has the ability to stimulate in situ formation of squaric acid (SQA)-iron(III) chelate. GOx-catalyzed oxidization of glucose leads to the formation of gluconic acid and hydrogen peroxide (H2O2). The latter can catalytically oxidize iron(II) to iron(III), which can rapidly (<1 min) coordinate with the SQA. Formation of the iron-squarate complex causes the color of the solution to change from bluish purple to bluish red accompanying the increasing absorbance with the increment of iron(III) concentration. On the basis of the SQA-iron(III) system, a new immunoassay protocol with GOx-labeled anti-PSA detection antibody can be designed for the detection of target PSA on capture antibody-functionalized magnetic immunosensing probe, monitored by recording the color or absorbance (λ = 468 nm) of the generated SQA-iron(III) chelate. The absorbance intensity shows to be dependent on the concentration of target PSA. A linear dependence between the absorbance and target PSA concentration is obtained under optimal conditions in the range from 1.0 pg mL(-1) to 30 ng mL(-1) with a detection limit (LOD) of 0.5 pg mL(-1) (0.5 ppt) estimated at the 3Sblank level. The sensitivity displays to be 3-5 orders of magnitude better than those of most commercialized human PSA ELISA kits. In addition, the developed colorimetric immunoassay was validated by assaying 12 human serum samples, receiving in good accordance with those obtained by the commercialized PSA ELISA kit. Importantly, the SQA-based immunosensing system can be further extended for the detection of other low-abundance proteins or biomarkers by controlling the target antibody.

  19. [A comparative study between the Vitek YBC and Microscan Walk Away RYID automated systems with conventional phenotypic methods for the identification of yeasts of clinical interest].

    PubMed

    Ferrara, Giuseppe; Mercedes Panizol, Maria; Mazzone, Marja; Delia Pequeneze, Maria; Reviakina, Vera

    2014-12-01

    The aim of this study was to compare the identification of clin- ically relevant yeasts by the Vitek YBC and Microscan Walk Away RYID automated methods with conventional phenotypic methods. One hundred and ninety three yeast strains isolated from clinical samples and five controls strains were used. All the yeasts were identified by the automated methods previously mentioned and conventional phenotypic methods such as carbohydrate assimilation, visualization of microscopic morphology on corn meal agar and the use of chromogenic agar. Variables were assessed by 2 x 2 contingency tables, McNemar's Chi square, the Kappa index, and concordance values were calculated, as well as major and minor errors for the automated methods. Yeasts were divided into two groups: (1) frequent isolation and (2) rare isolation. The Vitek YBC and Microscan Walk Away RYID systems were concordant in 88.4 and 85.9% respectively, when compared to conventional phenotypic methods. Although both automated systems can be used for yeasts identification, the presence of major and minor errors indicates the possibility of misidentifications; therefore, the operator of this equipment must use in parallel, phenotypic tests such as visualization of microscopic morphology on corn meal agar and chromogenic agar, especially against infrequently isolated yeasts. Automated systems are a valuable tool; however, the expertise and judgment of the microbiologist are an important strength to ensure the quality of the results.

  20. Fast methods of fungal and bacterial identification. MALDI-TOF mass spectrometry, chromogenic media.

    PubMed

    Siller-Ruiz, María; Hernández-Egido, Sara; Sánchez-Juanes, Fernando; González-Buitrago, José Manuel; Muñoz-Bellido, Juan Luis

    2017-05-01

    MALDI-TOF mass spectrometry is now a routine resource in Clinical Microbiology, because of its speed and reliability in the identification of microorganisms. Its performance in the identification of bacteria and yeasts is perfectly contrasted. The identification of mycobacteria and moulds is more complex, due to the heterogeneity of spectra within each species. The methodology is somewhat more complex, and expanding the size of species libraries, and the number of spectra of each species, will be crucial to achieve greater efficiency. Direct identification from blood cultures has been implemented, since its contribution to the management of severe patients is evident, but its application to other samples is more complex. Chromogenic media have also contributed to the rapid diagnosis in both bacteria and yeast, since they accelerate the diagnosis, facilitate the detection of mixed cultures and allow rapid diagnosis of resistant species. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  1. Analysis of cytokine mRNA expression using a novel chromogenic in situ hybridization method in pulmonary granulomas of cattle experimentally infected by aerosolized Mycobacterium bovis

    USDA-ARS?s Scientific Manuscript database

    Mycobacterium bovis is the cause of tuberculosis in most animal species, including cattle and is a serious zoonotic pathogen. In humans, M. bovis infection can result in disease clinically indistinguishable from that caused by Mycobacterium tuberculosis, the cause of most tuberculosis in humans. Reg...

  2. Spectrophotometric determination of copper in alkaline solutions and evaluation of some hydroxy-substituted 1,10-phenanthrolines as chromogenic reagents.

    PubMed

    Dunbar, W E; Schilt, A A

    1972-09-01

    Seven new hydroxy-substituted 1,10-phenanthroline derivatives have been evaluated as chromogenic reagents for the determination of copper in strongly alkaline solution. The most sensitive of these, 2,9-dimethyl-4,7-dihydroxy-1,10-phenanthroline, has proven to be highly effective in a simple, rapid procedure for determining trace amounts of copper in sodium hydroxide, potassium carbonate, sodium phosphate or ammonium hydroxide.

  3. Performance of the chromID Salmonella Elite chromogenic agar in comparison with CHROMagar™ Salmonella, Oxoid™ Brilliance™ Salmonella and Hektoen agars for the isolation of Salmonella from stool specimens.

    PubMed

    Martiny, Delphine; Dediste, Anne; Anglade, Claire; Vlaes, Linda; Moens, Catherine; Mohamed, Souad; Vandenberg, Olivier

    2016-10-01

    chromID™ Salmonella Elite is compared with 3 culture media commonly used for Salmonella isolation from stool specimens. As results were equivalent to other chromogenic media (100% sensitivity, 98% specificity), only financial arguments should guide the choice for a medium with respect to another. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Isolation and purification of monosialotetrahexosylgangliosides from pig brain by extraction and liquid chromatography.

    PubMed

    Bian, Liujiao; Yang, Jianting; Sun, Yu

    2015-10-01

    Monosialotetrahexosylganglioside (GM1), one of glycosphingolipids containing sialic acid, plays particularly important role in fighting against paralysis, dementia and other diseases caused by brain and nerve damage. In this work, a simple and highly efficient method with high yield was developed for isolation and purification of GM1 from pig brain. The method consisted of an extraction by chloroform-methanol-water and a two-step chromatographic separation by DEAE-Sepharose Fast Flow anion-exchange medium and Sephacryl S-100 HR size-exclusion medium. The purified GM1 was proved to be homogeneous and had a purity of >98.0% by high-performance anion-exchange and size-exclusion chromatography. The molecular weight was 30.0 kDa by high-performance size-exclusion chromatography and 1546.9 Da by electrospray ionization mass spectrometry. The chromogenic reaction by resorcinol-hydrochloric acid solution indicated that the purified GM1 showed a specific chromogenic reaction of sialic acid. Through this isolation and purification program, ~1.0 mg of pure GM1 could be captured from 500 g wet pig brain tissue and the yield of GM1 was around 0.022%, which was higher than the yields by other methods. The method may provide an alternative for isolation and purification of GM1 in other biological tissues. Copyright © 2015 John Wiley & Sons, Ltd.

  5. A combined disc method with resazurin agar plate assay for early phenotypic screening of KPC, MBL and OXA-48 carbapenemases among Enterobacteriaceae.

    PubMed

    Teethaisong, Y; Eumkeb, G; Nakouti, I; Evans, K; Hobbs, G

    2016-08-01

    To validate a combined disc method along with resazurin chromogenic agar for early screening and differentiation of Klebsiella pneumoniae carbapenemase, metallo-β-lactamase and OXA-48 carbapenemase-producing Enterobacteriaceae. The combined disc test comprising of meropenem alone and with EDTA, phenylboronic acid or both EDTA and phenylboronic acid, and temocillin alone were evaluated with the resazurin chromogenic agar plate assay against a total of 86 molecularly confirmed Enterobacteriaceae clinical isolates (11 metallo-β-lactamases, eight Kl. pneumoniae carbapenemases, 11 OXA-48, 32 AmpC and 15 extended-spectrum-β-lactamase producers and nine co-producers of extended-spectrum-β-lactamase and AmpC). The inhibition zone diameters were measured and interpreted at 7 h for the presence of carbapenemase. All carbapenemase producers were phenotypically distinguished by this assay with 100% sensitivity and specificity. This early phenotypic method is very simple, inexpensive, and reliable in the detection and differentiation of carbapenemase-producing Enterobacteriaceae. It could be exploited in any microbiological laboratory for diagnosis of these recalcitrant bacteria. This assay poses excellent performance in discrimination of Kl. pneumoniae carbapenemase, metallo-β-lactamase and OXA-48 carbapenemases within 7 h, which is much faster than conventional disc diffusion methods. The rapid detection could help clinicians screen patients, control infection and provide epidemiological surveillance. © 2016 The Society for Applied Microbiology.

  6. β-Glucuronidase-coupled assays of glucuronoyl esterases.

    PubMed

    Fraňová, Lucia; Puchart, Vladimír; Biely, Peter

    2016-10-01

    Glucuronoyl esterases (GEs) are microbial enzymes with potential to cleave the ester bonds between lignin alcohols and xylan-bound 4-O-methyl-d-glucuronic acid in plant cell walls. This activity renders GEs attractive research targets for biotechnological applications. One of the factors impeding the progress in GE research is the lack of suitable substrates. In this work, we report a facile preparation of methyl esters of chromogenic 4-nitrophenyl and 5-bromo-4-chloro-3-indolyl β-D-glucuronides for qualitative and quantitative GE assay coupled with β-glucuronidase as the auxiliary enzyme. The indolyl derivative affording a blue indigo-type product is suitable for rapid and sensitive assay of GE in commercial preparations as well as for high throughput screening of microorganisms and genomic and metagenomic libraries. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Evaluation of a chromogenic culture medium for isolation of Clostridium difficile within 24 hours.

    PubMed

    Perry, John D; Asir, Kerry; Halimi, Diane; Orenga, Sylvain; Dale, Joanne; Payne, Michelle; Carlton, Ruth; Evans, Jim; Gould, F Kate

    2010-11-01

    Rapid and effective methods for the isolation of Clostridium difficile from stool samples are desirable to obtain isolates for typing or to facilitate accurate diagnosis of C. difficile-associated diarrhea. We report on the evaluation of a prototype chromogenic medium (ID C. difficile prototype [IDCd]) for isolation of C. difficile. The chromogenic medium was compared using (i) 368 untreated stool samples that were also inoculated onto CLO medium, (ii) 339 stool samples that were subjected to alcohol shock and also inoculated onto five distinct selective agars, and (iii) standardized suspensions of 10 C. difficile ribotypes (untreated and alcohol treated) that were also inoculated onto five distinct selective agars. Two hundred thirty-six isolates of C. difficile were recovered from 368 untreated stool samples, and all but 1 of these strains (99.6%) were recovered on IDCd within 24 h, whereas 74.6% of isolates were recovered on CLO medium after 48 h. Of 339 alcohol-treated stool samples cultured onto IDCd and five other selective agars, C. difficile was recovered from 218 samples using a combination of all media. The use of IDCd allowed recovery of 96.3% of isolates within 24 h, whereas 51 to 83% of isolates were recovered within 24 h using the five other media. Finally, when they were challenged with pure cultures, all 10 ribotypes of C. difficile generated higher colony counts on IDCd irrespective of alcohol pretreatment or duration of incubation. We conclude that IDCd is an effective medium for isolation of C. difficile from stool samples within 24 h.

  8. Evaluation of a Chromogenic Culture Medium for Isolation of Clostridium difficile within 24 Hours ▿

    PubMed Central

    Perry, John D.; Asir, Kerry; Halimi, Diane; Orenga, Sylvain; Dale, Joanne; Payne, Michelle; Carlton, Ruth; Evans, Jim; Gould, F. Kate

    2010-01-01

    Rapid and effective methods for the isolation of Clostridium difficile from stool samples are desirable to obtain isolates for typing or to facilitate accurate diagnosis of C. difficile-associated diarrhea. We report on the evaluation of a prototype chromogenic medium (ID C. difficile prototype [IDCd]) for isolation of C. difficile. The chromogenic medium was compared using (i) 368 untreated stool samples that were also inoculated onto CLO medium, (ii) 339 stool samples that were subjected to alcohol shock and also inoculated onto five distinct selective agars, and (iii) standardized suspensions of 10 C. difficile ribotypes (untreated and alcohol treated) that were also inoculated onto five distinct selective agars. Two hundred thirty-six isolates of C. difficile were recovered from 368 untreated stool samples, and all but 1 of these strains (99.6%) were recovered on IDCd within 24 h, whereas 74.6% of isolates were recovered on CLO medium after 48 h. Of 339 alcohol-treated stool samples cultured onto IDCd and five other selective agars, C. difficile was recovered from 218 samples using a combination of all media. The use of IDCd allowed recovery of 96.3% of isolates within 24 h, whereas 51 to 83% of isolates were recovered within 24 h using the five other media. Finally, when they were challenged with pure cultures, all 10 ribotypes of C. difficile generated higher colony counts on IDCd irrespective of alcohol pretreatment or duration of incubation. We conclude that IDCd is an effective medium for isolation of C. difficile from stool samples within 24 h. PMID:20739493

  9. Chromogenic agar medium for detection and isolation of Escherichia coli serogroups O26, O45, O103, O111, O121, and O145 from fresh beef and cattle feces.

    PubMed

    Kalchayanand, Norasak; Arthur, Terrance M; Bosilevac, Joseph M; Wells, James E; Wheeler, Tommy L

    2013-02-01

    Non-O157 Shiga toxin-producing Escherichia coli (STEC) strains are clinically important foodborne pathogens. Unlike E. coli O157:H7, these foodborne pathogens have no unique biochemical characteristics to readily distinguish them from other E. coli strains growing on plating media. In this study, a chromogenic agar medium was developed in order to differentiate among non-O157 STEC strains of serogroups O26, O45, O103, O111, O121, and O145 on a single agar medium. The ability of this chromogenic agar medium to select and distinguish among these pathogens is based on a combination of utilization of carbohydrates, b -galactosidase activity, and resistance to selective agents. The agar medium in combination with immunomagnetic separation was evaluated and successfully allowed for the detection and isolation of these six serogroups from artificially contaminated fresh beef. The agar medium in combination with immunomagnetic separation also allowed successful detection and isolation of naturally occurring non-O157 STEC strains present in cattle feces. Thirty-five strains of the top six non-O157 STEC serogroups were isolated from 1,897 fecal samples collected from 271 feedlot cattle. This chromogenic agar medium could help significantly in routine screening for the top six non-O157 STEC serogroups from beef cattle and other food.

  10. Insertion and deletion mutagenesis of the human cytomegalovirus genome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spaete, R.R.; Mocarski, E.S.

    1987-10-01

    Studies on human cytomegalovirus (CMV) have been limited by a paucity of molecular genetic techniques available for manipulating the viral genome. The authors have developed methods for site-specific insertion and deletion mutagenesis of CMV utilizing a modified Escherichia coli lacZ gene as a genetic marker. The lacZ gene was placed under the control of the major ..beta.. gene regulatory signals and inserted into the viral genome by homologous recombination, disrupting one of two copies of this ..beta.. gene within the L-component repeats of CMV DNA. They observed high-level expression of ..beta..-galactosidase by the recombinant in a temporally authentic manner, withmore » levels of this enzyme approaching 1% of total protein in infected cells. Thus, CMV is an efficient vector for high-level expression of foreign gene products in human cells. Using back selection of lacZ-deficient virus in the presence of the chromogenic substrate 5-bromo-4-chloro-3-indolyl ..beta..-D-galactoside, they generated random endpoint deletion mutants. Analysis of these mutant revealed that CMV DNA sequences flanking the insert had been removed, thereby establishing this approach as a means of determining whether sequences flanking a lacZ insertion are dispensable for viral growth. In an initial test of the methods, they have shown that 7800 base pairs of one copy of L-component repeat sequences can be deleted without affecting viral growth in human fibroblasts.« less

  11. Transpeptidation reactions of a specific substrate catalyzed by the streptomyces R61 DD-peptidase: characterization of a chromogenic substrate and acyl acceptor design.

    PubMed

    Kumar, Ish; Pratt, R F

    2005-08-02

    The Streptomyces R61 dd-peptidase, a functional model for penicillin-binding proteins, catalyzes the hydrolysis and aminolysis of d-alanyl-d-alanine-terminating peptides by specific amines. In vivo, this reaction completes bacterial cell wall biosynthesis. For in vitro studies of this enzyme to date, various nonspecific acyl-donor substrates have been employed. Recently, however, a peptidoglycan-mimetic peptide substrate, glycyl-l-alpha-amino-epsilon-pimelyl-d-alanyl-d-alanine, has been described that is much more specific for this enzyme. In this paper, we describe the synthesis and kinetic characterization of an analogous thiolester substrate, 3-(N-glycyl-l-cysteinyl)-propanoyl-d-alanyl-d-thiolactate, that the enzyme hydrolyzes and aminolyzes very efficiently (k(cat)/K(m) = 1.0 x 10(7) s(-)(1) M(-)(1)). Direct or indirect, by means of a thiol trap, spectrophotometric monitoring of the reactions of this substrate is readily achieved. Deacylation of the enzyme is rate-determining under substrate saturation conditions, and therefore the aminolysis reaction can be directly studied. The results show that d-amino acids and certain Gly-l-Xaa dipeptides and tripeptides may act as acyl acceptors at the active site of the enzyme. d-Phenylalanine and Gly-l-Phe were the most effective d-amino acid and dipeptide acceptors, respectively. On the basis of the dual specificity of the active site for acceptors (d-amino acids and Gly-l-Xaa peptides), "dual function" acceptors were designed and synthesized. Two of these, aminomalon-(N-ethyl)amide and aminomalon-(N-phenethyl)amide, were particularly effective. It did seem, however, that the observed rates of reaction of these very effective acceptors may be limited by some common, possibly physical, step. More extended, peptidoglycan-like, acceptors were found to be essentially unreactive. The reasons for this counterintuitive behavior are discussed.

  12. A multi-substrate approach for functional metagenomics-based screening for (hemi)cellulases in two wheat straw-degrading microbial consortia unveils novel thermoalkaliphilic enzymes.

    PubMed

    Maruthamuthu, Mukil; Jiménez, Diego Javier; Stevens, Patricia; van Elsas, Jan Dirk

    2016-01-28

    Functional metagenomics is a promising strategy for the exploration of the biocatalytic potential of microbiomes in order to uncover novel enzymes for industrial processes (e.g. biorefining or bleaching pulp). Most current methodologies used to screen for enzymes involved in plant biomass degradation are based on the use of single substrates. Moreover, highly diverse environments are used as metagenomic sources. However, such methods suffer from low hit rates of positive clones and hence the discovery of novel enzymatic activities from metagenomes has been hampered. Here, we constructed fosmid libraries from two wheat straw-degrading microbial consortia, denoted RWS (bred on untreated wheat straw) and TWS (bred on heat-treated wheat straw). Approximately 22,000 clones from each library were screened for (hemi)cellulose-degrading enzymes using a multi-chromogenic substrate approach. The screens yielded 71 positive clones for both libraries, giving hit rates of 1:440 and 1:1,047 for RWS and TWS, respectively. Seven clones (NT2-2, T5-5, NT18-17, T4-1, 10BT, NT18-21 and T17-2) were selected for sequence analyses. Their inserts revealed the presence of 18 genes encoding enzymes belonging to twelve different glycosyl hydrolase families (GH2, GH3, GH13, GH17, GH20, GH27, GH32, GH39, GH53, GH58, GH65 and GH109). These encompassed several carbohydrate-active gene clusters traceable mainly to Klebsiella related species. Detailed functional analyses showed that clone NT2-2 (containing a beta-galactosidase of ~116 kDa) had highest enzymatic activity at 55 °C and pH 9.0. Additionally, clone T5-5 (containing a beta-xylosidase of ~86 kDa) showed > 90% of enzymatic activity at 55 °C and pH 10.0. This study employed a high-throughput method for rapid screening of fosmid metagenomic libraries for (hemi)cellulose-degrading enzymes. The approach, consisting of screens on multi-substrates coupled to further analyses, revealed high hit rates, as compared with recent other studies. Two clones, 10BT and T4-1, required the presence of multiple substrates for detectable activity, indicating a new avenue in library activity screening. Finally, clones NT2-2, T5-5 and NT18-17 were found to encode putative novel thermo-alkaline enzymes, which could represent a starting point for further biotechnological applications.

  13. Isolation and Biochemical Characterization of a New Thrombin-Like Serine Protease from Bothrops pirajai Snake Venom

    PubMed Central

    Zaqueo, Kayena D.; Kayano, Anderson M.; Simões-Silva, Rodrigo; Moreira-Dill, Leandro S.; Fernandes, Carla F. C.; Fuly, André L.; Maltarollo, Vinícius G.; Honório, Kathia M.; da Silva, Saulo L.; Acosta, Gerardo; Caballol, Maria Antonia O.; de Oliveira, Eliandre; Albericio, Fernando; Calderon, Leonardo A.; Soares, Andreimar M.; Stábeli, Rodrigo G.

    2014-01-01

    This paper presents a novel serine protease (SP) isolated from Bothrops pirajai, a venomous snake found solely in Brazil that belongs to the Viperidae family. The identified SP, named BpirSP-39, was isolated by three chromatographic steps (size exclusion, bioaffinity, and reverse phase chromatographies). The molecular mass of BpirSP-39 was estimated by SDS-PAGE and confirmed by mass spectrometry (39,408.32 Da). The protein was able to form fibrin networks, which was not observed in the presence of serine protease inhibitors, such as phenylmethylsulfonyl fluoride (PMSF). Furthermore, BpirSP-39 presented considerable thermal stability and was apparently able to activate factor XIII of the blood coagulation cascade, unlike most serine proteases. BpirSP-39 was capable of hydrolyzing different chromogenic substrates tested (S-2222, S-2302, and S-2238) while Cu2+ significantly diminished BspirSP-39 activity on the three tested substrates. The enzyme promoted platelet aggregation and also exhibited fibrinogenolytic, fibrinolytic, gelatinolytic, and amidolytic activities. The multiple alignment showed high sequence similarity to other thrombin-like enzymes from snake venoms. These results allow us to conclude that a new SP was isolated from Bothrops pirajai snake venom. PMID:24719874

  14. Automatic Digital Analysis of Chromogenic Media for Vancomycin-Resistant-Enterococcus Screens Using Copan WASPLab

    PubMed Central

    Faron, Matthew L.; Coon, Christopher; Liebregts, Theo; van Bree, Anita; Jansz, Arjan R.; Soucy, Genevieve; Korver, John

    2016-01-01

    Vancomycin-resistant enterococci (VRE) are an important cause of health care-acquired infections (HAIs). Studies have shown that active surveillance of high-risk patients for VRE colonization can aid in reducing HAIs; however, these screens generate a significant cost to the laboratory and health care system. Digital imaging capable of differentiating negative and “nonnegative” chromogenic agar can reduce the labor cost of these screens and potentially improve patient care. In this study, we evaluated the performance of the WASPLab Chromogenic Detection Module (CDM) (Copan, Brescia, Italy) software to analyze VRE chromogenic agar and compared the results to technologist plate reading. Specimens collected at 3 laboratories were cultured using the WASPLab CDM and plated to each site's standard-of-care chromogenic media, which included Colorex VRE (BioMed Diagnostics, White City, OR) or Oxoid VRE (Oxoid, Basingstoke, United Kingdom). Digital images were scored using the CDM software after 24 or 40 h of growth, and all manual reading was performed using digital images on a high-definition (HD) monitor. In total, 104,730 specimens were enrolled and automation agreed with manual analysis for 90.1% of all specimens tested, with sensitivity and specificity of 100% and 89.5%, respectively. Automation results were discordant for 10,348 specimens, and all discordant images were reviewed by a laboratory supervisor or director. After a second review, 499 specimens were identified as representing missed positive cultures falsely called negative by the technologist, 1,616 were identified as containing borderline color results (negative result but with no package insert color visible), and 8,234 specimens were identified as containing colorimetric pigmentation due to residual matrix from the specimen or yeast (Candida). Overall, the CDM was accurate at identifying negative VRE plates, which comprised 84% (87,973) of the specimens in this study. PMID:27413193

  15. Comparison of Spectrophotometric Methods for the Determination of Copper in Sugar Cane Spirit.

    PubMed

    Soares, Sarah Adriana R; Costa, Silvânio Silvério L; Araujo, Rennan Geovanny O; Teixeira, Leonardo Sena Gomes; Dantas, Alailson Falcão

    2018-05-01

    Three spectrophotometric methods were developed for the determination of copper (Cu) in sugar cane spirit using the chromogenic reagents neocuproine, cuprizone, and bathocuproine. Experimental conditions, such as reagent concentration, reducer concentration, pH, buffer concentration, the order of addition of reagents, and the stability of the complexes, were optimized. The work range was established from 1.0 to 10.0 µg/mL, with correlation coefficients of >0.999 for all three optimized methods. The methods were evaluated regarding accuracy by addition and recovery tests at five concentration levels, and the obtained recoveries ranged from 91 to 105% (n = 3). Precision was expressed as RSD (relative standard deviation), with values ranging from 0.01 to 0.17% (n = 10). The method using the chromogenic reagent cuprizone presented the greatest molar absorptivity, followed by bathocuproine and neocuproine. The methods were applied for the determination of Cu in sugar cane spirit, and the results were compared with a reference method by flame atomic absorption spectrometry (FAAS). Calibration curve solutions for FAAS analysis were prepared in a 40% (v/v) alcohol medium in a range of concentrations from 0.5 up to 5 µg/mL. Measurements for Cu determination were carried out at a wavelength of 324.7 nm. The concentrations obtained for Cu in sugar cane spirit samples from Brazil were between 1.99 and 12.63 µg/mL, and about 75% of the samples presented Cu concentrations above the limit established by Brazilian legislation (5.0 µg/mL or 5.0 mg/L).

  16. Comparison of performance of the novel chromogenic spectra VRE agar to that of bile esculin azide and Campylobacter agars for detection of vancomycin-resistant enterococci in fecal samples.

    PubMed

    Jenkins, S G; Raskoshina, L; Schuetz, A N

    2011-11-01

    A total of 142 stool specimens were evaluated for vancomycin-resistant enterococcus (VRE). Twenty-four-hour sensitivities and specificities, respectively, were 98% and 95% for Spectra VRE chromogenic agar (Remel, Lenexa, KS), 86% and 92% for bile esculin azide with vancomycin (BEAV; Remel), and 96.5% and 92% for Campylobacter agar (CAMPY; Remel). Spectra VRE and CAMPY are significantly more sensitive at 24 h than BEAV.

  17. Comparative Study of Biological Activities of Venom from Colubrid Snakes Rhabdophis tigrinus (Yamakagashi) and Rhabdophis lateralis

    PubMed Central

    Komori, Yumiko; Hifumi, Toru; Yamamoto, Akihiko; Sakai, Atsushi; Sawabe, Kyoko; Nikai, Toshiaki

    2017-01-01

    Rhabdophis lateralis, a colubrid snake distributed throughout the continent of Asia, has recently undergone taxonomic revisions. Previously, Rhabdophis lateralis was classified as a subspecies of R. tigrinus (Yamakagashi) until 2012, when several genetic differences were discovered which classified this snake as its own species. To elucidate the toxicity of venom from this poorly studied colubrid, various biological activities were compared between the venom from the two snake species. The components of their venom were compared by the elution profiles of reversed-phase HPLC and SDS-PAGE, and gel filtrated fractions were tested for effects on blood coagulation. Proteolytic activities of these fractions were also assayed by using synthetic substrates, fibrinogen, and matrix proteins. Similar to the R. tigrinus venom, the higher molecular weight fraction of R. lateralis venom contained a prothrombin activator. Both prothrombin time (PT) and activated partial thromboplastin time (APTT) of human plasma were shortened by the addition of R. lateralis and R. tigrinus venom. The thrombin formation was estimated by the uses of SDS-PAGE and chromogenic substrates. These venom fractions also possessed very specific proteinase activity on human fibrinogen, but the substrates for matrix metalloproteinase, such as collagen and laminin, were not hydrolyzed. However, there were some notable differences in reactivity to synthetic substrates for matrix metalloproteinase, and R. tigrinus venom possessed relatively higher activity. Our chemical investigation indicates that the components included in both venoms resemble each other closely. However, the ratio of components and proteolytic activity of some ingredients are slightly different, indicating differences between two closely-related snakes. PMID:29149042

  18. Chromogenic Factor VIII Assays for Improved Diagnosis of Hemophilia A.

    PubMed

    Rodgers, Susan; Duncan, Elizabeth

    2017-01-01

    Hemophilia A is an inherited bleeding disorder caused by a reduced level of factor VIII coagulant activity (FVIII:C) in blood. Bleeding episodes may occur spontaneously in the severe form of hemophilia or after trauma in the milder forms. It is important that patients are diagnosed correctly, which includes placing them into the correct severity category of the disorder so that appropriate treatment can be given. Diagnosis is made by determination of the amount of FVIII:C in the blood, usually using a one-stage factor VIII:C assay. However, approximately one third of patients with mild or moderate hemophilia will have much lower results by the chromogenic assay, with some of them having normal results by the one-stage assay. The chromogenic factor VIII assay is used in some specialized hemophilia reference centers and is recommended for the diagnosis of mild hemophilia A, as this assay is considered to better reflect the severity status of hemophilia patients than the one-stage assay.

  19. Screening, identification, and characterization of a GH43 family β-xylosidase/α-arabinofuranosidase from a compost microbial metagenome.

    PubMed

    Matsuzawa, Tomohiko; Kaneko, Satoshi; Yaoi, Katsuro

    2015-11-01

    A putative glycoside hydrolase family 43 β-xylosidase/α-arabinofuranosidase (CoXyl43) that promotes plant biomass saccharification was isolated via functional screening of a compost microbial metagenomic library and characterized. CoXyl43 promoted the saccharification of plant biomasses, including xylans (xylan and arabinoxylan), rice straw, and Erianthus, by degrading xylooligosaccharide residues to monosaccharide residues. The recombinant CoXyl43 protein exhibited both β-xylosidase and α-arabinofuranosidase activities for chromogenic substrates, with optimal activity at pH 7.5 and 55 °C. Both of these activities were inactivated by ethanol, dimethylsulfoxide, and zinc and copper ions but were activated by manganese ions. Only the β-xylosidase activity of recombinant CoXyl43 was enhanced in the presence of calcium ions. These results indicate that CoXyl43 exhibits unique enzymatic properties useful for biomass saccharification.

  20. Sulfated Pentagalloylglucoside is a Potent, Allosteric, and Selective Inhibitor of Factor XIa

    PubMed Central

    Al-Horani, Rami A.; Ponnusamy, Pooja; Mehta, Akul Y.; Gailani, David; Desai, Umesh R.

    2013-01-01

    Inhibition of factor XIa (FXIa) is a novel paradigm for developing anticoagulants without major bleeding consequences. We present the discovery of sulfated pentagalloylglucoside (6) as a highly selective inhibitor of human FXIa. Biochemical screening of a focused library led to the identification of 6, a sulfated aromatic mimetic of heparin. Inhibitor 6 displayed a potency of 551 nM against FXIa, which was at least 200-fold more selective than other relevant enzymes. It also prevented activation of factor IX and prolonged human plasma and whole blood clotting. Inhibitor 6 reduced VMAX of FXIa hydrolysis of chromogenic substrate without affecting the KM suggesting an allosteric mechanism. Competitive studies showed that 6 bound in the heparin-binding site of FXIa. No allosteric small molecule has been discovered to date that exhibits equivalent potency against FXIa. Inhibitor 6 is expected to open up a major route to allosteric FXIa anticoagulants with clinical relevance. PMID:23316863

  1. The abp gene in Geobacillus stearothermophilus T-6 encodes a GH27 β-L-arabinopyranosidase.

    PubMed

    Salama, Rachel; Alalouf, Onit; Tabachnikov, Orly; Zolotnitsky, Gennady; Shoham, Gil; Shoham, Yuval

    2012-07-30

    In this study we demonstrate that the abp gene in Geobacillus stearothermophilus T-6 encodes a family 27 glycoside hydrolase β-L-arabinopyranosidase. The catalytic constants towards the chromogenic substrate pNP-β-L-arabinopyranoside were 0.8±0.1 mM, 6.6±0.3 s(-1), and 8.2±0.3 s(-1) mM(-1) for K(m), k(cat) and k(cat)/K(m), respectively. (13)C NMR spectroscopy unequivocally showed that Abp is capable of removing β-L-arabinopyranose residues from the natural arabino-polysaccharide, larch arabinogalactan. Most family 27 enzymes are active on galactose and contain a conserved Asp residue, whereas in Abp this residue is Ile67, which shifts the specificity of the enzyme towards arabinopyranoside. Copyright © 2012 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  2. Effect of acyl chain length on selective biocatalytic deacylation on O-aryl glycosides and separation of anomers.

    PubMed

    Aggarwal, Neha; Arya, Anu; Mathur, Divya; Singh, Sukhdev; Tyagi, Abhilash; Kumar, Rajesh; Rana, Neha; Singh, Rajendra; Prasad, Ashok K

    2014-04-01

    It has been demonstrated that Lipozyme® TL IM (Thermomyces lanuginosus lipase immobilised on silica) can selectively deacylate the ester function involving the C-5' hydroxyl group of α-anomers over the other acyl functions of anomeric mixture of peracylated O-aryl α,β-D-ribofuranoside. The analysis of results of biocatalytic deacylation reaction revealed that the reaction time decreases with the increase in the acyl chain length from C1 to C4. The unique selectivity of Lipozyme® TL IM has been harnessed for the separation of anomeric mixture of peracylated O-aryl α,β-D-ribofuranosides, The lipase mediated selective deacylation methodology has been used for the synthesis of O-aryl α-D-ribofuranosides and O-aryl β-D-ribofuranosides in pure forms, which can be used as chromogenic substrate for the detection of pathogenic microbial parasites containing glycosidases. Copyright © 2014. Published by Elsevier Inc.

  3. Faster and economical screening for vancomycin-resistant enterococci by sequential use of chromogenic agar and real-time polymerase chain reaction.

    PubMed

    Tan, Thean Yen; Jiang, Boran; Ng, Lily Siew Yong

    2017-08-01

    Screening for vancomycin-resistant enterococci (VRE) by culture takes days to generate results, while polymerase chain reaction (PCR) testing directly from clinical specimens lacks specificity. The aims of this study were to develop a real-time PCR to detect and identify Enterococcus faecium, Enterococcus faecalis, and vanA and vanB genes, and to evaluate the impact of this PCR on test-reporting times when performing it directly from suspect VRE isolates present on screening chromogenic media. The tetraplex PCR primers were designed to amplify E. faecium, E. faecalis, and vanA and vanB genes, with melt-curve analysis of PCR products. Following analytical and clinical validation of the molecular assay, PCR testing was performed for target colonies present on VRE chromogenic media. PCR results were evaluated against conventional phenotypic identification and susceptibility testing, with the time to result being monitored for both modalities. A total of 519 colonies from clinical specimens were tested concurrently by real-time PCR and phenotypic methods. In all, 223 isolates were identified with phenotypic vancomycin resistance (vanA, n = 108; vanB, n = 105; non-vanA/vanB = 10), with complete agreement between PCR and phenotypic testing for vancomycin-resistant E. faecium and E. faecalis. The majority (88.6%) of PCR results were reported, on average, 24.8 hours earlier than those of phenotypic testing, with 68% reduction in total costs. The use of culture on selective media, followed by direct colony PCR confirmation allows faster and economical VRE screening. Copyright © 2015. Published by Elsevier B.V.

  4. Comparison of media for enumeration of coliform bacteria and Escherichia coli in non-disinfected water.

    PubMed

    Pitkänen, Tarja; Paakkari, Piia; Miettinen, Ilkka T; Heinonen-Tanski, Helvi; Paulin, Lars; Hänninen, Marja-Liisa

    2007-03-01

    In this work alternative media for detection and enumeration of E. coli and coliform bacteria were compared to the reference method ISO 9308-1 (LTTC) using non-disinfected water samples with background flora. The alternative media included LES Endo agar medium (LES Endo), Colilert-18 with 51-well Quanti-tray (Colilert), Chromocult Coliform agar (CC), Harlequin E. coli/Coliform medium (HECM) and Chromogenic Escherichia coli/Coliform medium (CECM). A total of 110 samples of groundwater, bathing water and spiked water was used. Our results revealed that confirmation of coliform bacteria counts is necessary, not only on lactose-based LTTC and LES Endo media, but also on the chromogenic agar media tested, due to the growth of oxidase positive colonies. LTTC and CC media also allowed the growth of some morphologically typical coliform colonies containing gram-positive bacteria. The recovery of coliform bacteria was lower on LES Endo than on LTTC. In most cases Colilert, CC, HECM and CECM gave higher coliform counts than LTTC. The use of the LTTC medium led to higher E. coli counts than obtained with any of the alternative mediums. There are three explanations for this: (1) high sensitivity of LTTC, (2) false positives on LTTC or (3) false negatives especially with Colilert, but also with chromogenic agar media. Although LTTC was found to be a very sensitive medium, the high degree of background growth of non-disinfected waters disturbed substantially the use of it. In conclusion, our results suggest that Colilert, CC and CECM are potential alternative media for detection of coliform bacteria and E. coli from non-disinfected water.

  5. Technical note: a pilot study using a mouse mastitis model to study differences between bovine associated coagulase-negative staphylococci.

    PubMed

    Breyne, K; De Vliegher, S; De Visscher, A; Piepers, S; Meyer, E

    2015-02-01

    Coagulase-negative staphylococci (CNS) are a group of bacteria classified as either minor mastitis pathogens or commensal microbiota. Recent research suggests species- and even strain-related epidemiological and genetic differences within the large CNS group. The current pilot study investigated in 2 experiments whether a mouse mastitis model validated for bovine Staphylococcus aureus can be used to explore further differences between CNS species and strains. In a first dose titration experiment, a low inoculum dose of S. aureus Newbould 305 (positive control) was compared with increasing inoculum doses of a Staphylococcus chromogenes strain originating from a chronic bovine intramammary infection to a sham-inoculated mammary glands (negative control). In contrast to the high bacterial growth following inoculation with S. aureus, S. chromogenes was retrieved in very low levels at 24 h postinduction (p.i.). In a second experiment, the inflammation inflicted by 3 CNS strains was studied in mice. The host immune response induced by the S. chromogenes intramammary strain was compared with the one induced by a Staphylococcus fleurettii strain originating from cow bedding sawdust and by a S. chromogenes strain originating from a teat apex of a heifer. As expected, at 28 and 48 h p.i., low bacterial growth and local neutrophil influx in the mammary gland were induced by all CNS strains. As hypothesized, bacterial growth p.i. was the lowest for S. fleurettii compared with that induced by the 2 S. chromogenes strains, and the overall immune response established by the 3 CNS strains was less pronounced compared with the one induced by S. aureus. Proinflammatory cytokine profiling revealed that S. aureus locally induced IL-6 and IL-1β but not TNF-α, whereas, overall, CNS-inoculated glands lacked a strong cytokine host response but also induced IL-1β locally. Compared with both other CNS strains, S. chromogenes from the teat apex inflicted a more variable IL-1β response characterized by a more intense local reaction in several mice. This pilot study suggests that an intraductal mouse model can mimic bovine CNS mastitis and has potential as a complementary in vivo tool for future CNS mastitis research. Furthermore, it indicates that epidemiologically different bovine CNS species or strains induce a differential host innate immune response in the murine mammary gland. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. A high throughput screen for biomining cellulase activity from metagenomic libraries.

    PubMed

    Mewis, Keith; Taupp, Marcus; Hallam, Steven J

    2011-02-01

    Cellulose, the most abundant source of organic carbon on the planet, has wide-ranging industrial applications with increasing emphasis on biofuel production (1). Chemical methods to modify or degrade cellulose typically require strong acids and high temperatures. As such, enzymatic methods have become prominent in the bioconversion process. While the identification of active cellulases from bacterial and fungal isolates has been somewhat effective, the vast majority of microbes in nature resist laboratory cultivation. Environmental genomic, also known as metagenomic, screening approaches have great promise in bridging the cultivation gap in the search for novel bioconversion enzymes. Metagenomic screening approaches have successfully recovered novel cellulases from environments as varied as soils (2), buffalo rumen (3) and the termite hind-gut (4) using carboxymethylcellulose (CMC) agar plates stained with congo red dye (based on the method of Teather and Wood (5)). However, the CMC method is limited in throughput, is not quantitative and manifests a low signal to noise ratio (6). Other methods have been reported (7,8) but each use an agar plate-based assay, which is undesirable for high-throughput screening of large insert genomic libraries. Here we present a solution-based screen for cellulase activity using a chromogenic dinitrophenol (DNP)-cellobioside substrate (9). Our library was cloned into the pCC1 copy control fosmid to increase assay sensitivity through copy number induction (10). The method uses one-pot chemistry in 384-well microplates with the final readout provided as an absorbance measurement. This readout is quantitative, sensitive and automated with a throughput of up to 100X 384-well plates per day using a liquid handler and plate reader with attached stacking system.

  7. The Methodology Applied in DPPH, ABTS and Folin-Ciocalteau Assays Has a Large Influence on the Determined Antioxidant Potential.

    PubMed

    Abramovič, Helena; Grobin, Blaž; Poklar, Nataša; Cigić, Blaž

    2017-06-01

    Antioxidant potential (AOP) is not only the property of the matrix analyzed but also depends greatly on the methodology used. The chromogenic radicals 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS•+), 2,2-diphenyl-1-picrylhydrazyl (DPPH•) and Folin-Ciocalteu (FC) assay were applied to estimate how the method and the composition of the assay solvent influence the AOP determined for coffee, tea, beer, apple juice and dietary supplements. Large differences between the AOP values depending on the reaction medium were observed, with the highest AOP determined mostly in the FC assay. In reactions with chromogenic radicals several fold higher values of AOP were obtained in buffer pH 7.4 than in water or methanol. The type of assay and solvent composition have similar influences on the reactivity of a particular antioxidant, either pure or as part of a complex matrix. The reaction kinetics of radicals with antioxidants in samples reveals that AOP depends strongly on incubation time, yet differently for each sample analyzed and the assay applied.

  8. Sensor node for remote monitoring of waterborne disease-causing bacteria.

    PubMed

    Kim, Kyukwang; Myung, Hyun

    2015-05-05

    A sensor node for sampling water and checking for the presence of harmful bacteria such as E. coli in water sources was developed in this research. A chromogenic enzyme substrate assay method was used to easily detect coliform bacteria by monitoring the color change of the sampled water mixed with a reagent. Live webcam image streaming to the web browser of the end user with a Wi-Fi connected sensor node shows the water color changes in real time. The liquid can be manipulated on the web-based user interface, and also can be observed by webcam feeds. Image streaming and web console servers run on an embedded processor with an expansion board. The UART channel of the expansion board is connected to an external Arduino board and a motor driver to control self-priming water pumps to sample the water, mix the reagent, and remove the water sample after the test is completed. The sensor node can repeat water testing until the test reagent is depleted. The authors anticipate that the use of the sensor node developed in this research can decrease the cost and required labor for testing samples in a factory environment and checking the water quality of local water sources in developing countries.

  9. Structural profiling of individual glycosphingolipids in a single thin-layer chromatogram by multiple sequential immunodetection matched with Direct IR-MALDI-o-TOF mass spectrometry.

    PubMed

    Souady, Jamal; Soltwisch, Jens; Dreisewerd, Klaus; Haier, Jörg; Peter-Katalinić, Jasna; Müthing, Johannes

    2009-11-15

    The thin-layer chromatography (TLC) immunoenzyme overlay assay is a widely used tool for antibody-mediated identification of glycosphingolipids (GSLs) in mixtures. However, because the majority of GSLs is left unexamined in a chromatogram of a single assay, we developed a novel method that permits detection of various GSLs by sequential multiple immunostaining combined with individual coloring of GSLs in the same chromatogram. Specific staining was achieved by means of primary anti-GSL antibodies, directed against lactosylceramide, globotriaosylceramide, and globotetraosylceramide, in conjunction with alkaline phosphatase (AP)- or horseradish peroxidase (HRP)-conjugated secondary antibodies together with the appropriate chromogenic substrates. Triple coloring with 5-bromo-4-chloro-3-indolyl phosphate (BCIP)-AP, Fast Red-AP, and 3,3'-diaminobenzidine (DAB)-HRP resulted in blue, red, and black precipitates, respectively, following three sequential immunostaining rounds. Structures of antibody-detected GSLs were determined by direct coupling of TLC with infrared matrix-assisted laser desorption/ionization orthogonal time-of-flight mass spectrometry. This combinatorial technique was used to demonstrate structural GSL profiling of crude lipid extracts from human hepatocellular cancer. This powerful technology allows efficient structural characterization of GSLs in small tissue samples and marks a further step forward in the emerging field of glycosphingolipidomics.

  10. Comparison of Performance of the Novel Chromogenic Spectra VRE Agar to That of Bile Esculin Azide and Campylobacter Agars for Detection of Vancomycin-Resistant Enterococci in Fecal Samples ▿

    PubMed Central

    Jenkins, S. G.; Raskoshina, L.; Schuetz, A. N.

    2011-01-01

    A total of 142 stool specimens were evaluated for vancomycin-resistant enterococcus (VRE). Twenty-four-hour sensitivities and specificities, respectively, were 98% and 95% for Spectra VRE chromogenic agar (Remel, Lenexa, KS), 86% and 92% for bile esculin azide with vancomycin (BEAV; Remel), and 96.5% and 92% for Campylobacter agar (CAMPY; Remel). Spectra VRE and CAMPY are significantly more sensitive at 24 h than BEAV. PMID:21880967

  11. Human plasma-derived immunoglobulin G fractionated by an aqueous two-phase system, caprylic acid precipitation, and membrane chromatography has a high purity level and is free of detectable in vitro thrombogenic activity.

    PubMed

    Vargas, M; Segura, Á; Wu, Y-W; Herrera, M; Chou, M-L; Villalta, M; León, G; Burnouf, T

    2015-02-01

    Instituto Clodomiro Picado has developed an immunoglobulin G (IgG) plasma fractionation process combining a polyethylene glycol/phosphate aqueous two-phase system (ATPS), caprylic acid precipitation and anion-exchange membrane chromatography. We evaluated the purity and in vitro thrombogenicity of such IgG, in line with current international requirements. Contributions of the different production steps to reduce thrombogenicity were assessed at 0·2 l-scale, and then the methodology was scaled-up to a 10 l-scale and final products (n = 3) were analysed. Purity, immunoglobulin composition, and subclass distribution were determined by electrophoretic and immunochemical methods. The in vitro thrombogenic potential was determined by a thrombin generation assay (TGA) using a Technothrombin fluorogenic substrate. Prekallikrein activator (PKA), plasmin, factor Xa, thrombin and thrombin-like activities were assessed using S-2302, S-2251, S-2222, S-2238 and S-2288 chromogenic substrates, respectively, and FXI by an ELISA. The thrombogenicity markers were reduced mostly during the ATPS step and were found to segregate mostly into the discarded liquid upper phase. The caprylic acid precipitation eliminated the residual procoagulant activity. The IgG preparations made from the 10 l-batches contained 100% gamma proteins, low residual IgA and undetectable IgM. The IgG subclass distribution was not substantially affected by the process. TGA and amidolytic activities revealed an undetectable in vitro thrombogenic risk and the absence of proteolytic enzymes in the final product. Fractionating human plasma by an ATPS combined with caprylic acid and membrane chromatography resulted in an IgG preparation of high purity and free of a detectable in vitro thrombogenic risk. © 2014 International Society of Blood Transfusion.

  12. Factors responsible for subclinical mastitis in cows caused by Staphylococcus chromogenes and its susceptibility to antibiotics based on bap, fnbA, eno, mecA, tetK, and ermA genes.

    PubMed

    Bochniarz, M; Adaszek, Ł; Dzięgiel, B; Nowaczek, A; Wawron, W; Dąbrowski, R; Szczubiał, M; Winiarczyk, S

    2016-12-01

    The aim of this study was to recognize selected factors of virulence determining the adhesion of Staphylococcus chromogenes to cows' udder tissues in subclinical mastitis and to evaluate the susceptibility of this pathogen to antibiotics. The subjects of the study were 38 isolates of Staph. chromogenes from 335 samples of milk from cows with subclinical coagulase-negative staphylococci mastitis. Somatic cell count ranged between 216,000 and 568,000/mL of milk (average 356,000/mL of milk). We confirmed the ability to produce slime in 24 isolates (63.2%), and the ability to produce protease in 29 isolates (76.3%). In each slime-producing isolate, the bap gene was not found, and the fnbA and eno genes were not detected. In vitro tests showed that ceftiofur had the highest effectiveness against Staph. chromogenes (89.5% of susceptible isolates). Minimum inhibitory concentrations ranged from 0.06 to 2µg/mL for susceptible isolates. The minimum concentrations required to inhibit growth of 90 and 50% of the isolates for ceftiofur were at or below the cutoffs recommended by the Clinical and Laboratory Standards Institute (2 and 0.06µg/mL, respectively). A significant percentage of the isolates were susceptible to other β-lactam antibiotics: amoxicillin with clavulanic acid (84.2%) and ampicillin (81.6%). The lowest effectiveness among β-lactams was for penicillin (73.7% of susceptible isolates), and the minimum inhibitory concentration for penicillin ranged from <0.06 to 8µg/mL. None of the examined isolates had the mecA gene, but β-lactamase was detected in 4 isolates (10.5%). Erythromycin and oxytetracycline exhibited the lowest activity against Staph. chromogenes (71.1 and 63.2% of susceptible isolates, respectively). The genes tetK (6 isolates) and ermA (1 isolate) were also detected. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Detection and determination of organophosphorus insecticides in tissues by thin-layer chromatography.

    PubMed

    Tewari, S N; Harpalani, S P

    1977-01-11

    The toxicological analysis of 12 common organophosphorus insecticides is described. Suitable methods for the extraction of organophosphorus insecticides from tissues are proposed. The detection, identification and estimation of these insecticides by thin-layer chromatography is described for 25 solvent systems and a series of chromogenic reagents. The distribution of insecticides in human body tissues in five cases of poisoning by ethyl parathion, malathion, dimethoate, sumithion and phosphamidon has also been studied.

  14. Diagnosis of asymptomatic bacteriuria and associated risk factors among pregnant women in mangalore, karnataka, India.

    PubMed

    Rajaratnam, Annie; Baby, Neha Maria; Kuruvilla, Thomas S; Machado, Santhosh

    2014-09-01

    Asymptomatic bacteriuria (AB) is common inwomen and increases in prevalence with age or sexual activity. Prompt detection and treatment of this condition and associated factors decreases complications like acute pyleonephritis, intrauterine growth retardation and preterm labour. Chromogenic media is a versatile tool in rapid primary screening of the causative organisms considerably reducing daily routine workload. To determine the prevalence of AB among pregnant women in a tertiary care set-up and analyse the contributory risk factors, its effects on pregnancy and the role of chromogenic media in the laboratory diagnosis of these cases. Urine samples of all pregnant women attending pre-natal check-ups with no genitourinary complaints, history of fever or antibiotic intake were collected for Gram stain, culture and antibiotic sensitivity tests. A second urine specimen for culture and sensitivity testing was obtained from those with significant bacteriuria. The results were compared with patients showing negative urine cultures. The overall prevalence of this clinical condition in our study was 13.2%. The significant isolates were Klebsiella pneumonia and E.coli and the most common risk factor was a previous history of urinary tract infection. The isolates were easily identified by using chromogenic agar ( HiCrome ) but colonies of uncommon pathogens like Acinetobacter and Streptococcus species appeared white and needed further identification. Screening of pregnant women for AB at first prenatal checkup helps analyse the associated factors and prevents its effects on pregnancy. The use of a chromogenic media can enhance reporting accuracy and will be an effective tool to monitor these cases routinely.

  15. Automated Scoring of Chromogenic Media for Detection of Methicillin-Resistant Staphylococcus aureus by Use of WASPLab Image Analysis Software.

    PubMed

    Faron, Matthew L; Buchan, Blake W; Vismara, Chiara; Lacchini, Carla; Bielli, Alessandra; Gesu, Giovanni; Liebregts, Theo; van Bree, Anita; Jansz, Arjan; Soucy, Genevieve; Korver, John; Ledeboer, Nathan A

    2016-03-01

    Recently, systems have been developed to create total laboratory automation for clinical microbiology. These systems allow for the automation of specimen processing, specimen incubation, and imaging of bacterial growth. In this study, we used the WASPLab to validate software that discriminates and segregates positive and negative chromogenic methicillin-resistant Staphylococcus aureus (MRSA) plates by recognition of pigmented colonies. A total of 57,690 swabs submitted for MRSA screening were enrolled in the study. Four sites enrolled specimens following their standard of care. Chromogenic agar used at these sites included MRSASelect (Bio-Rad Laboratories, Redmond, WA), chromID MRSA (bioMérieux, Marcy l'Etoile, France), and CHROMagar MRSA (BD Diagnostics, Sparks, MD). Specimens were plated and incubated using the WASPLab. The digital camera took images at 0 and 16 to 24 h and the WASPLab software determined the presence of positive colonies based on a hue, saturation, and value (HSV) score. If the HSV score fell within a defined threshold, the plate was called positive. The performance of the digital analysis was compared to manual reading. Overall, the digital software had a sensitivity of 100% and a specificity of 90.7% with the specificity ranging between 90.0 and 96.0 across all sites. The results were similar using the three different agars with a sensitivity of 100% and specificity ranging between 90.7 and 92.4%. These data demonstrate that automated digital analysis can be used to accurately sort positive from negative chromogenic agar cultures regardless of the pigmentation produced. Copyright © 2016 Faron et al.

  16. In situ analysis of proteins at high temperatures mediated by capillary-flow hydrothermal UV-vis spectrophotometer with a water-soluble chromogenic reagent.

    PubMed

    Kawamura, Kunio; Nagayoshi, Hiroki; Yao, Toshio

    2010-05-14

    In situ monitoring of quantities, interactions, and conformations of proteins is essential for the study of biochemistry under hydrothermal environments and the analysis of hyperthermophilic organisms in natural hydrothermal systems on Earth. We have investigated the potential of a capillary-flow hydrothermal UV-vis spectrophotometer (CHUS) for performing in situ measurements of proteins and determining their behavior at extremely high temperatures, in combination with a chromogenic reagents probe, which interacts with the proteins. The spectral shift obtained using a combination of water-soluble porphyrin (TPPS) and bovine serum albumin (BSA) was the best among the spectral shifts obtained using different combinations of chromogenic reagents and proteins. The association behavior of TPPS with BSA was investigated in detail using CHUS at temperatures up to 175 degrees C and the association constant (K(ass)) of TPPS with BSA was successfully determined at temperatures up to 100 degrees C. The lnK(ass) values were inversely proportional to the T(-1) values in the temperature range 50-100 degrees C. These analyses showed for the first time that the decrease of association of TPPS with BSA is due to the conformational change, fragmentation, and/or denaturing of BSA rather than the decrease of the hydrophobic association between TPPS and BSA. This study conclusively demonstrates the usability of the CHUS system with a chromogenic reagent as an in situ detection and measurement system for thermostable proteins at extremely high temperatures. Copyright 2010 Elsevier B.V. All rights reserved.

  17. A multi writable thiophene-based selective and reversible chromogenic fluoride probe with dual -NH functionality

    NASA Astrophysics Data System (ADS)

    Vishwakarma, Siddharth; Kumar, Ajit; Pandey, Abha; Upadhyay, K. K.

    2017-01-01

    A chromogenic fluoride probe bearing bis imine groups having dual -NH functionality (BSB) has been designed, synthesised and structurally characterized by its single crystal X-ray diffraction studies. The BSB could visually and spectroscopically recognise F- with high selectivity over other anions by exhibiting intense chromogenic response (from colourless to red) for F- in acetonitrile solution. The UV-visible titration and 1H NMR titration experiments indicated that the observed changes occur via a combined process including hydrogen bonding and deprotonation between the BSB and F-. Moreover theoretical calculations at the Density Functional Theory (DFT) level shed further light upon probe design strategy and the nature of interactions between BSB and F-. The limit of detection and binding constant of BSB towards F- were found to be 6.9 × 10- 7 M and 1.42 ± 0.069 × 108 M- 2 respectively. Finally, by using F- and H+ as chemical inputs and the absorbance as output, a INHIBIT logic gate was constructed, which exhibits "Multi-write" ability without obvious degradation in its optical output.

  18. In situ self-assembly of polarizing chromogen nanofibers catalyzed with hybrid films of gold nanoparticles and cellulose

    NASA Astrophysics Data System (ADS)

    Liu, Zhiming; Wu, Wenjian

    2017-09-01

    Hybrid materials of metal nanoparticles and biopolymers with catalytic properties are very promising to be used as detectors in biochemical reactions. In this work, the catalytic properties and relevant in situ self-assembly abilities of hybrid films of gold nanoparticles (GNPs) and cellulose for the oxidation of benign chromogen 3,3‧,5,5‧-tetramethylbenzidine (TMB) with hydrogen peroxide (H2O2) are revealed for the first time. The peroxidase-like properties of hybrid films are inherited from those of colloidal GNPs and increase with their contents of GNPs. It is discovered that the oxidized products of TMB grow in situ and assemble into rod-like and tumbleweed-like nanofiber assemblies on hybrid films. The rod-like nanofibers show a magnificent polarizing phenomenon under polarized light because of polycrystalline globular nanoparticles inside. The in situ self-assembly of polarizing nanofibers of chromogen catalyzed with hybrid films creates an opportunity for the synthesis of novel organic nanomaterials and the enhanced detection of biochemical products under polarized light.

  19. VIDAS Listeria species Xpress (LSX).

    PubMed

    Johnson, Ronald; Mills, John

    2013-01-01

    The AOAC GovVal study compared the VIDAS Listeria species Xpress (LSX) to the Health Products and Food Branch MFHPB-30 reference method for detection of Listeria on stainless steel. The LSX method utilizes a novel and proprietary enrichment media, Listeria Xpress broth, enabling detection of Listeria species in environmental samples with the automated VIDAS in a minimum of 26 h. The LSX method also includes the use of the chromogenic media, chromID Ottaviani Agosti Agar (OAA) and chromID Lmono for confirmation of LSX presumptive results. In previous AOAC validation studies comparing VIDAS LSX to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference methods, the LSX method was approved as AOAC Official Method 2010.02 for the detection of Listeria species in dairy products, vegetables, seafood, raw meats and poultry, and processed meats and poultry, and as AOAC Performance Tested Method 100501 in a variety of foods and on environmental surfaces. The GovVal comparative study included 20 replicate test portions each at two contamination levels for stainless steel where fractionally positive results (5-15 positive results/20 replicate portions tested) were obtained by at least one method at one level. Five uncontaminated controls were included. In the stainless steel artificially contaminated surface study, there were 25 confirmed positives by the VIDAS LSX assay and 22 confirmed positives by the standard culture methods. Chi-square analysis indicated no statistical differences between the VIDAS LSX method and the MFHPB-30 standard methods at the 5% level of significance. Confirmation of presumptive LSX results with the chromogenic OAA and Lmono media was shown to be equivalent to the appropriate reference method agars. The data in this study demonstrate that the VIDAS LSX method is an acceptable alternative method to the MFHPB-30 standard culture method for the detection of Listeria species on stainless steel.

  20. Identification, typing, ecology and epidemiology of coagulase negative staphylococci associated with ruminants.

    PubMed

    Vanderhaeghen, Wannes; Piepers, Sofie; Leroy, Frédéric; Van Coillie, Els; Haesebrouck, Freddy; De Vliegher, Sarne

    2015-01-01

    Since phenotypic methods to identify coagulase negative staphylococci (CNS) from the milk of ruminants often yield unreliable results, methods for molecular identification based on gene sequencing or fingerprinting techniques have been developed. In addition to culture-based detection of isolates, culture-independent methods may be of interest. On the basis of molecular studies, the five CNS species commonly causing intramammary infections (IMI) are Staphylococcus chromogenes, Staphylococcus epidermidis, Staphylococcus haemolyticus, Staphylococcus simulans and Staphylococcus xylosus. Current knowledge suggests that S. chromogenes is a bovine-adapted species, with most cases of IMI due to this bacterium being opportunistic. S. haemolyticus also appears to be an opportunistic pathogen, but this bacterium occupies a variety of habitats, the importance of which as a source of IMI remains to be elucidated. S. xylosus appears to be a versatile species, but little is known of its epidemiology. S. epidermidis is considered to be a human-adapted species and most cases of IMI appear to arise from human sources, but the organism is capable of residing in other habitats. S. simulans typically causes contagious IMI, but opportunistic cases also occur and the ecology of this bacterium requires further study. Further studies of the ecology and epidemiology of CNS as a cause of IMI in cattle are required, along with careful attention to classification of these bacteria and the diseases they cause. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Purification of a chymotrypsin-like enzyme present on adult Schistosoma mansoni worms from infected mice and its characterization as a host carboxylesterase.

    PubMed

    Igetei, Joseph E; Liddell, Susan; El-Faham, Marwa; Doenhoff, Michael J

    2016-04-01

    A serine protease-like enzyme found in detergent extracts of Schistosoma mansoni adult worms perfused from infected mice has been purified from mouse blood and further characterized. The enzyme is approximately 85 kDa and hydrolyses N-acetyl-DL-phenylalanine β-naphthyl-ester, a chromogenic substrate for chymotrypsin-like enzymes. The enzyme from S. mansoni worms appears to be antigenically and enzymatically similar to a molecule that is present in normal mouse blood and so is seemingly host-derived. The enzyme was partially purified by depleting normal mouse serum of albumin using sodium chloride and cold ethanol, followed by repeated rounds of purification by one-dimensional sodium dodecyl sulphate polyacrylamide gel electrophoresis. The purified material was subjected to tandem mass spectrometry and its derived peptides found to belong to mouse carboxylesterase 1C. Its ability to hydrolyse α- or β-naphthyl acetates, which are general esterase substrates, has been confirmed. A similar carboxylesterase was purified and characterized from rat blood. Additional evidence to support identification of the enzyme as a carboxylesterase has been provided. Possible roles of the enzyme in the mouse host-parasite relationship could be to ease the passage of worms through the host's blood vessels and/or in immune evasion.

  2. Comparative study of selective chromogenic (chromID VRE) and bile esculin agars for isolation and identification of vanB-containing vancomycin-resistant enterococci from feces and rectal swabs.

    PubMed

    Grabsch, E A; Ghaly-Derias, S; Gao, W; Howden, B P

    2008-12-01

    The new chromogenic agar chromID VRE (cIDVRE; bioMérieux) was compared with bile esculin agar (BD) containing 6 mg/liter vancomycin for the detection of colonization with vanB-containing vancomycin-resistant enterococci (VRE). At 48 h of incubation, the results obtained with both media were comparable. However, cIDVRE detected significantly more VRE at 24 h (39.3% versus 21.3%, P = 0.003), and its use may facilitate the timely implementation of infection control procedures.

  3. A simple and low cost dual-wavelength β-correction spectrophotometric determination and speciation of mercury(II) in water using chromogenic reagent 4-(2-thiazolylazo) resorcinol

    NASA Astrophysics Data System (ADS)

    Al-Bagawi, A. H.; Ahmad, W.; Saigl, Z. M.; Alwael, H.; Al-Harbi, E. A.; El-Shahawi, M. S.

    2017-12-01

    The most common problems in spectrophotometric determination of various complex species originate from the background spectral interference. Thus, the present study aimed to overcome the spectral matrix interference for the precise analysis and speciation of mercury(II) in water by dual-wavelength β-correction spectrophotometry using 4-(2-thiazolylazo) resorcinol (TAR) as chromogenic reagent. The principle was based on measuring the correct absorbance for the formed complex of mercury(II) ions with TAR reagent at 547 nm (lambda max). Under optimized conditions, a linear dynamic range of 0.1-2.0 μg mL- 1 with correlation coefficient (R2) of 0.997 were obtained with lower limits of detection (LOD) of 0.024 μg mL- 1 and limit of quantification (LOQ) of 0.081 μg mL- 1. The values of RSD and relative error (RE) obtained for β-correction method and single wavelength spectrophotometry were 1.3, 1.32% and 4.7, 5.9%, respectively. The method was validated in tap and sea water in terms of the data obtained from inductively coupled plasma-optical emission spectrometry (ICP-OES) using student's t and F tests. The developed methodology satisfactorily overcomes the spectral interference in trace determination and speciation of mercury(II) ions in water.

  4. Evaluation of conventional and alternative monitoring methods for a recreational marine beach with nonpoint source of fecal contamination.

    PubMed

    Shibata, Tomoyuki; Solo-Gabriele, Helena M; Sinigalliano, Christopher D; Gidley, Maribeth L; Plano, Lisa R W; Fleisher, Jay M; Wang, John D; Elmir, Samir M; He, Guoqing; Wright, Mary E; Abdelzaher, Amir M; Ortega, Cristina; Wanless, David; Garza, Anna C; Kish, Jonathan; Scott, Troy; Hollenbeck, Julie; Backer, Lorraine C; Fleming, Lora E

    2010-11-01

    The objectives of this work were to compare enterococci (ENT) measurements based on the membrane filter, ENT(MF) with alternatives that can provide faster results including alternative enterococci methods (e.g., chromogenic substrate (CS), and quantitative polymerase chain reaction (qPCR)), and results from regression models based upon environmental parameters that can be measured in real-time. ENT(MF) were also compared to source tracking markers (Staphylococcus aureus, Bacteroidales human and dog markers, and Catellicoccus gull marker) in an effort to interpret the variability of the signal. Results showed that concentrations of enterococci based upon MF (<2 to 3320 CFU/100 mL) were significantly different from the CS and qPCR methods (p < 0.01). The correlations between MF and CS (r = 0.58, p < 0.01) were stronger than between MF and qPCR (r ≤ 0.36, p < 0.01). Enterococci levels by MF, CS, and qPCR methods were positively correlated with turbidity and tidal height. Enterococci by MF and CS were also inversely correlated with solar radiation but enterococci by qPCR was not. The regression model based on environmental variables provided fair qualitative predictions of enterococci by MF in real-time, for daily geometric mean levels, but not for individual samples. Overall, ENT(MF) was not significantly correlated with source tracking markers with the exception of samples collected during one storm event. The inability of the regression model to predict ENT(MF) levels for individual samples is likely due to the different sources of ENT impacting the beach at any given time, making it particularly difficult to to predict short-term variability of ENT(MF) for environmental parameters.

  5. Colorimetric detection of genetically modified organisms based on exonuclease III-assisted target recycling and hemin/G-quadruplex DNAzyme amplification.

    PubMed

    Zhang, Decai; Wang, Weijia; Dong, Qian; Huang, Yunxiu; Wen, Dongmei; Mu, Yuejing; Yuan, Yong

    2017-12-21

    An isothermal colorimetric method is described for amplified detection of the CaMV 35S promoter sequence in genetically modified organism (GMO). It is based on (a) target DNA-triggered unlabeled molecular beacon (UMB) termini binding, and (b) exonuclease III (Exo III)-assisted target recycling, and (c) hemin/G-quadruplex (DNAzyme) based signal amplification. The specific binding of target to the G-quadruplex sequence-locked UMB triggers the digestion of Exo III. This, in turn, releases an active G-quadruplex segment and target DNA for successive hybridization and cleavage. The Exo III impellent recycling of targets produces numerous G-quadruplex sequences. These further associate with hemin to form DNAzymes and hence will catalyze H 2 O 2 -mediated oxidation of the chromogenic enzyme substrate ABTS 2- causing the formation of a green colored product. This finding enables a sensitive colorimetric determination of GMO DNA (at an analytical wavelength of 420 nm) at concentrations as low as 0.23 nM. By taking advantage of isothermal incubation, this method does not require sophisticated equipment or complicated syntheses. Analyses can be performed within 90 min. The method also discriminates single base mismatches. In our perception, it has a wide scope in that it may be applied to the detection of many other GMOs. Graphical abstract An isothermal and sensitive colorimetric method is described for amplified detection of CaMV 35S promoter sequence in genetically modified organism (GMO). It is based on target DNA-triggered molecular beacon (UMB) termini-binding and exonuclease III assisted target recycling, and on hemin/G-quadruplex (DNAzyme) signal amplification.

  6. Evolution and characterization of a new reversibly photoswitching chromogenic protein, Dathail

    DOE PAGES

    Langan, Patricia S.; Close, Devin W.; Coates, Leighton; ...

    2016-03-18

    In this paper, we report the engineering of a new reversibly switching chromogenic protein, Dathail. Dathail was evolved from the extremely thermostable fluorescent proteins thermal green protein (TGP) and eCGP123 using directed evolution and ratiometric sorting. Dathail has two spectrally distinct chromogenic states with low quantum yields, corresponding to absorbance in a ground state with a maximum at 389 nm, and a photo-induced metastable state with a maximum at 497 nm. In contrast to all previously described photoswitchable proteins, both spectral states of Dathail are non-fluorescent. The photo-induced chromogenic state of Dathail has a lifetime of ~ 50 min atmore » 293 K and pH 7.5 as measured by UV–Vis spectrophotometry, returning to the ground state through thermal relaxation. X-ray crystallography provided structural insights supporting a change in conformation and coordination in the chromophore pocket as being responsible for Dathail's photoswitching. Neutron crystallography, carried out for the first time on a protein from the green fluorescent protein family, showed a distribution of hydrogen atoms revealing protonation of the chromophore 4-hydroxybenzyl group in the ground state. Additionally, the neutron structure also supports the hypothesis that the photo-induced proton transfer from the chromophore occurs through water-mediated proton relay into the bulk solvent. Beyond its spectroscopic curiosity, Dathail has several characteristics that are improvements for applications, including low background fluorescence, large spectral separation, rapid switching time, and the ability to switch many times. Therefore, Dathail is likely to be extremely useful in the quickly developing fields of imaging and biosensors, including photochromic Förster resonance energy transfer, high-resolution microscopy, and live tracking within the cell.« less

  7. Methyl green and nitrotetrazolium blue chloride co-expression in colon tissue: A hyperspectral microscopic imaging analysis

    NASA Astrophysics Data System (ADS)

    Li, Qingli; Liu, Hongying; Wang, Yiting; Sun, Zhen; Guo, Fangmin; Zhu, Jianzhong

    2014-12-01

    Histological observation of dual-stained colon sections is usually performed by visual observation under a light microscope, or by viewing on a computer screen with the assistance of image processing software in both research and clinical settings. These traditional methods are usually not sufficient to reliably differentiate spatially overlapping chromogens generated by different dyes. Hyperspectral microscopic imaging technology offers a solution for these constraints as the hyperspectral microscopic images contain information that allows differentiation between spatially co-located chromogens with similar but different spectra. In this paper, a hyperspectral microscopic imaging (HMI) system is used to identify methyl green and nitrotetrazolium blue chloride in dual-stained colon sections. Hyperspectral microscopic images are captured and the normalized score algorithm is proposed to identify the stains and generate the co-expression results. Experimental results show that the proposed normalized score algorithm can generate more accurate co-localization results than the spectral angle mapper algorithm. The hyperspectral microscopic imaging technology can enhance the visualization of dual-stained colon sections, improve the contrast and legibility of each stain using their spectral signatures, which is helpful for pathologist performing histological analyses.

  8. Visual and efficient immunosensor technique for advancing biomedical applications of quantum dots on Salmonella detection and isolation

    NASA Astrophysics Data System (ADS)

    Tang, Feng; Pang, Dai-Wen; Chen, Zhi; Shao, Jian-Bo; Xiong, Ling-Hong; Xiang, Yan-Ping; Xiong, Yan; Wu, Kai; Ai, Hong-Wu; Zhang, Hui; Zheng, Xiao-Li; Lv, Jing-Rui; Liu, Wei-Yong; Hu, Hong-Bing; Mei, Hong; Zhang, Zhen; Sun, Hong; Xiang, Yun; Sun, Zi-Yong

    2016-02-01

    It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here by applying fluorescent nanobioprobes on a specially-designed cellulose-based swab (a solid-phase enrichment system). The selective and chromogenic medium used on this swab can achieve the ultrasensitive amplification of target bacteria and form chromogenic colonies in situ based on a simple biochemical reaction. More importantly, because this swab can serve as an attachment site for the targeted pathogens to immobilize and immunologically capture nanobioprobes, our mAb-conjugated QD bioprobes were successfully applied on the solid-phase enrichment system to capture the fluorescence of targeted colonies under a designed excitation light instrument based on blue light-emitting diodes combined with stereomicroscopy or laser scanning confocal microscopy. Compared with the traditional methods using 4-7 days to isolate Salmonella from the bacterial mixture, this method took only 2 days to do this, and the process of initial screening and preliminary diagnosis can be completed in only one and a half days. Furthermore, the limit of detection can reach as low as 101 cells per mL Salmonella on the background of 105 cells per mL non-Salmonella (Escherichia coli, Proteus mirabilis or Citrobacter freundii, respectively) in experimental samples, and even in human anal ones. The visual and efficient immunosensor technique may be proved to be a favorable alternative for screening and isolating Salmonella in a large number of samples related to public health surveillance.It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here by applying fluorescent nanobioprobes on a specially-designed cellulose-based swab (a solid-phase enrichment system). The selective and chromogenic medium used on this swab can achieve the ultrasensitive amplification of target bacteria and form chromogenic colonies in situ based on a simple biochemical reaction. More importantly, because this swab can serve as an attachment site for the targeted pathogens to immobilize and immunologically capture nanobioprobes, our mAb-conjugated QD bioprobes were successfully applied on the solid-phase enrichment system to capture the fluorescence of targeted colonies under a designed excitation light instrument based on blue light-emitting diodes combined with stereomicroscopy or laser scanning confocal microscopy. Compared with the traditional methods using 4-7 days to isolate Salmonella from the bacterial mixture, this method took only 2 days to do this, and the process of initial screening and preliminary diagnosis can be completed in only one and a half days. Furthermore, the limit of detection can reach as low as 101 cells per mL Salmonella on the background of 105 cells per mL non-Salmonella (Escherichia coli, Proteus mirabilis or Citrobacter freundii, respectively) in experimental samples, and even in human anal ones. The visual and efficient immunosensor technique may be proved to be a favorable alternative for screening and isolating Salmonella in a large number of samples related to public health surveillance. Electronic supplementary information (ESI) available: One additional figure (Fig. S1), two additional tables (Tables S1 and S2) and additional information. See DOI: 10.1039/c5nr07424j

  9. Thiourea based novel chromogenic sensor for selective detection of fluoride and cyanide anions in organic and aqueous media.

    PubMed

    Kumar, Vinod; Kaushik, M P; Srivastava, A K; Pratap, Ajay; Thiruvenkatam, V; Row, T N Guru

    2010-03-17

    Novel chromogenic thiourea based sensors 4,4'-bis-[3-(4-nitrophenyl) thiourea] diphenyl ether 1 and 4,4'-bis-[3-(4-nitrophenyl) thiourea] diphenyl methane 2 having nitrophenyl group as signaling unit have been synthesized and characterized by spectroscopic techniques and X-ray crystallography. The both sensors show visual detection, UV-vis and NMR spectral changes in presence of fluoride and cyanide anions in organic solvent as well as in aqueous medium. The absorption spectra indicated the formation of complex between host and guest is in 1:2 stoichiometric ratios. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Chromogenic detection of yam mosaic virus by closed-tube reverse transcription loop-mediated isothermal amplification (CT-RT-LAMP).

    PubMed

    Nkere, Chukwuemeka K; Oyekanmi, Joshua O; Silva, Gonçalo; Bömer, Moritz; Atiri, Gabriel I; Onyeka, Joseph; Maroya, Norbert G; Seal, Susan E; Kumar, P Lava

    2018-04-01

    A closed-tube reverse transcription loop-mediated isothermal amplification (CT-RT-LAMP) assay was developed for the detection of yam mosaic virus (YMV, genus Potyvirus) infecting yam (Dioscorea spp.). The assay uses a set of six oligonucleotide primers targeting the YMV coat protein region, and the amplification products in YMV-positive samples are visualized by chromogenic detection with SYBR Green I dye. The CT-RT-LAMP assay detected YMV in leaf and tuber tissues of infected plants. The assay is 100 times more sensitive in detecting YMV than standard RT-PCR, while maintaining the same specificity.

  11. A multi writable thiophene-based selective and reversible chromogenic fluoride probe with dual -NH functionality.

    PubMed

    Vishwakarma, Siddharth; Kumar, Ajit; Pandey, Abha; Upadhyay, K K

    2017-01-05

    A chromogenic fluoride probe bearing bis imine groups having dual -NH functionality (BSB) has been designed, synthesised and structurally characterized by its single crystal X-ray diffraction studies. The BSB could visually and spectroscopically recognise F(-) with high selectivity over other anions by exhibiting intense chromogenic response (from colourless to red) for F(-) in acetonitrile solution. The UV-visible titration and (1)H NMR titration experiments indicated that the observed changes occur via a combined process including hydrogen bonding and deprotonation between the BSB and F(-). Moreover theoretical calculations at the Density Functional Theory (DFT) level shed further light upon probe design strategy and the nature of interactions between BSB and F(-). The limit of detection and binding constant of BSB towards F(-) were found to be 6.9×10(-7)M and 1.42±0.069×10(8)M(-2) respectively. Finally, by using F(-)and H(+) as chemical inputs and the absorbance as output, a INHIBIT logic gate was constructed, which exhibits "Multi-write" ability without obvious degradation in its optical output. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. A mouse mastitis model to study the effects of the intramammary infusion of a food-grade Lactococcus lactis strain.

    PubMed

    Camperio, Cristina; Armas, Federica; Biasibetti, Elena; Frassanito, Paolo; Giovannelli, Carlo; Spuria, Liliana; D'Agostino, Claudia; Tait, Sabrina; Capucchio, Maria Teresa; Marianelli, Cinzia

    2017-01-01

    Lactococcus lactis is one of the most important microorganisms in the dairy industry and has "generally recognized as safe" (GRAS) status. L. lactis belongs to the group of lactic acid bacteria (LAB) and is encountered in a wide range of environments. Recently, the use of the intramammary infusion of a live culture of LAB has been investigated as a new antibiotic alternative for treating mastitis in dairy ruminants. Controversial results are described in literature regarding its efficacy and safety. In this study we conducted in-depth investigation of the mammary gland immune response induced by intramammary inoculum of a live culture of L. lactis LMG 7930 using the mouse mastitis model. Overnight cultures either of L. lactis (≈ 107 CFU) or of the mastitis pathogens Staphylococcus chromogenes (≈ 105 CFU) or S. aureus (≈ 102 CFU/ml) were injected into the mouse inguinal glands. A double injection, consisting of S. chromogenes first and then L. lactis, was also investigated. Bacterial recovery from the gland and inflammatory cell infiltration were assessed. L. lactis-treated and control glands were analysed for proinflammatory cytokine production. Microbiological results showed that L. lactis was able to survive in the mammary gland 24 h post infection, as were the mastitis pathogens S. chromogenes and S. aureus. L. lactis reduced S. chromogenes survival in the glands and increased its own survival ability by coexisting with the pathogen. Histology showed that L. lactis-treated glands presented variable histological features, ranging from undamaged tissue with no inflammatory cell infiltrate to severe PMN infiltrate with focal areas of tissue damage. S. aureus-treated glands showed the most severe histological grade of inflammation despite the fact that the inoculum size was the smallest. In contrast, most S. chromogenes-treated glands showed normal structures with no infiltration or lesions. Significant increases in IL-1β and TNF-α levels were also found in L. lactis-inoculated glands. The above findings seem to suggest that food-grade L. lactis at a high-inoculum dose such as an overnight culture may elicit a suppurative inflammatory response in the mammary gland, thus becoming a potential mastitis-causing pathogen. Because of the unpredictable potential of L. lactis in acting as a potential mastitis pathogen, this organism cannot be considered a safe treatment for bovine mastitis.

  13. A mouse mastitis model to study the effects of the intramammary infusion of a food-grade Lactococcus lactis strain

    PubMed Central

    Biasibetti, Elena; Frassanito, Paolo; Giovannelli, Carlo; Spuria, Liliana; D’Agostino, Claudia; Tait, Sabrina; Capucchio, Maria Teresa

    2017-01-01

    Lactococcus lactis is one of the most important microorganisms in the dairy industry and has “generally recognized as safe” (GRAS) status. L. lactis belongs to the group of lactic acid bacteria (LAB) and is encountered in a wide range of environments. Recently, the use of the intramammary infusion of a live culture of LAB has been investigated as a new antibiotic alternative for treating mastitis in dairy ruminants. Controversial results are described in literature regarding its efficacy and safety. In this study we conducted in-depth investigation of the mammary gland immune response induced by intramammary inoculum of a live culture of L. lactis LMG 7930 using the mouse mastitis model. Overnight cultures either of L. lactis (≈ 107 CFU) or of the mastitis pathogens Staphylococcus chromogenes (≈ 105 CFU) or S. aureus (≈ 102 CFU/ml) were injected into the mouse inguinal glands. A double injection, consisting of S. chromogenes first and then L. lactis, was also investigated. Bacterial recovery from the gland and inflammatory cell infiltration were assessed. L. lactis-treated and control glands were analysed for proinflammatory cytokine production. Microbiological results showed that L. lactis was able to survive in the mammary gland 24 h post infection, as were the mastitis pathogens S. chromogenes and S. aureus. L. lactis reduced S. chromogenes survival in the glands and increased its own survival ability by coexisting with the pathogen. Histology showed that L. lactis-treated glands presented variable histological features, ranging from undamaged tissue with no inflammatory cell infiltrate to severe PMN infiltrate with focal areas of tissue damage. S. aureus-treated glands showed the most severe histological grade of inflammation despite the fact that the inoculum size was the smallest. In contrast, most S. chromogenes-treated glands showed normal structures with no infiltration or lesions. Significant increases in IL-1β and TNF-α levels were also found in L. lactis-inoculated glands. The above findings seem to suggest that food-grade L. lactis at a high-inoculum dose such as an overnight culture may elicit a suppurative inflammatory response in the mammary gland, thus becoming a potential mastitis-causing pathogen. Because of the unpredictable potential of L. lactis in acting as a potential mastitis pathogen, this organism cannot be considered a safe treatment for bovine mastitis. PMID:28873396

  14. Characterization of a Novel Subgroup of Extracellular Medium-Chain-Length Polyhydroxyalkanoate Depolymerases from Actinobacteria

    PubMed Central

    Gangoiti, Joana; Santos, Marta; Prieto, María Auxiliadora; de la Mata, Isabel; Llama, María J.

    2012-01-01

    Nineteen medium-chain-length (mcl) poly(3-hydroxyalkanoate) (PHA)-degrading microorganisms were isolated from natural sources. From them, seven Gram-positive and three Gram-negative bacteria were identified. The ability of these microorganisms to hydrolyze other biodegradable plastics, such as short-chain-length (scl) PHA, poly(ε-caprolactone) (PCL), poly(ethylene succinate) (PES), and poly(l-lactide) (PLA), has been studied. On the basis of the great ability to degrade different polyesters, Streptomyces roseolus SL3 was selected, and its extracellular depolymerase was biochemically characterized. The enzyme consisted of one polypeptide chain of 28 kDa with a pI value of 5.2. Its maximum activity was observed at pH 9.5 with chromogenic substrates. The purified enzyme hydrolyzed mcl PHA and PCL but not scl PHA, PES, and PLA. Moreover, the mcl PHA depolymerase can hydrolyze various substrates for esterases, such as tributyrin and p-nitrophenyl (pNP)-alkanoates, with its maximum activity being measured with pNP-octanoate. Interestingly, when poly(3-hydroxyoctanoate-co-3-hydroxyhexanoate [11%]) was used as the substrate, the main hydrolysis product was the monomer (R)-3-hydroxyoctanoate. In addition, the genes of several Actinobacteria strains, including S. roseolus SL3, were identified on the basis of the peptide de novo sequencing of the Streptomyces venezuelae SO1 mcl PHA depolymerase by tandem mass spectrometry. These enzymes did not show significant similarity to mcl PHA depolymerases characterized previously. Our results suggest that these distinct enzymes might represent a new subgroup of mcl PHA depolymerases. PMID:22865072

  15. Sulfated Low Molecular Weight Lignins, Allosteric Inhibitors of Coagulation Proteinases via the Heparin Binding Site, Significantly Alter the Active Site of Thrombin and Factor Xa Compared to Heparin

    PubMed Central

    Henry, Brian L.; Desai, Umesh R.

    2014-01-01

    Sulfated low molecular weight lignins (LMWLs) have been found to bind in the heparin binding sites of coagulation proteinases. LMWLs represent a library of diverse non-carbohydrate, aromatic molecules which are structures different from heparin, but still potently inhibit thrombin and factor Xa. To better understand their mechanism of action, we studied the effects of three sulfated LMWLs (CDSO3, FDSO3, and SDSO3) on the active sites of thrombin and factor Xa. LMWLs were found to uniformly inhibit the catalytic activity of thrombin and factor Xa, regardless of the substrate used. Michaelis-Menten kinetic studies indicate that maximal velocity of hydrolysis of each chromogenic substrate decreases significantly in the presence of sulfated LMWLs, while the effect on Michaelis constant is dependent on the nature of the substrate. These studies indicate that LMWLs inhibit thrombin and factor Xa through allosteric disruption of the catalytic apparatus, specifically through the catalytic step. As opposed to heparin, LMWLs significantly alter the binding of the active site fluorescent ligand p-aminobenzamidine. LMWLs also had a greater effect on the molecular orientation of fluorescein-labeled His 57 than heparin. The molecular geometry surrounding the most important catalytic amino acid, Ser 195, was significantly altered by the binding of LMWLs while heparin had no measurable effect on Ser 195. These results further advance the concept of sulfated LMWLs as heparin mimics and will aid the design of anticoagulants based on their novel scaffold. PMID:25242245

  16. Sulfated low molecular weight lignins, allosteric inhibitors of coagulation proteinases via the heparin binding site, significantly alter the active site of thrombin and factor xa compared to heparin.

    PubMed

    Henry, Brian L; Desai, Umesh R

    2014-11-01

    Sulfated low molecular weight lignins (LMWLs) have been found to bind in the heparin binding sites of coagulation proteinases. LMWLs represent a library of diverse non-carbohydrate, aromatic molecules which are structures different from heparin, but still potently inhibit thrombin and factor Xa. To better understand their mechanism of action, we studied the effects of three sulfated LMWLs (CDSO3, FDSO3, and SDSO3) on the active sites of thrombin and factor Xa. LMWLs were found to uniformly inhibit the catalytic activity of thrombin and factor Xa, regardless of the substrate used. Michaelis-Menten kinetic studies indicate that maximal velocity of hydrolysis of each chromogenic substrate decreases significantly in the presence of sulfated LMWLs, while the effect on Michaelis constant is dependent on the nature of the substrate. These studies indicate that LMWLs inhibit thrombin and factor Xa through allosteric disruption of the catalytic apparatus, specifically through the catalytic step. As opposed to heparin, LMWLs significantly alter the binding of the active site fluorescent ligand p-aminobenzamidine. LMWLs also had a greater effect on the molecular orientation of fluorescein-labeled His 57 than heparin. The molecular geometry surrounding the most important catalytic amino acid, Ser 195, was significantly altered by the binding of LMWLs while heparin had no measurable effect on Ser 195. These results further advance the concept of sulfated LMWLs as heparin mimics and will aid the design of anticoagulants based on their novel scaffold. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Colorimetric Detection of Specific DNA Segments Amplified by Polymerase Chain Reactions

    NASA Astrophysics Data System (ADS)

    Kemp, David J.; Smith, Donald B.; Foote, Simon J.; Samaras, N.; Peterson, M. Gregory

    1989-04-01

    The polymerase chain reaction (PCR) procedure has many potential applications in mass screening. We describe here a general assay for colorimetric detection of amplified DNA. The target DNA is first amplified by PCR, and then a second set of oligonucleotides, nested between the first two, is incorporated by three or more PCR cycles. These oligonucleotides bear ligands: for example, one can be biotinylated and the other can contain a site for a double-stranded DNA-binding protein. After linkage to an immobilized affinity reagent (such as a cloned DNA-binding protein, which we describe here) and labeling with a second affinity reagent (for example, avidin) linked to horseradish peroxidase, reaction with a chromogenic substrate allows detection of the amplified DNA. This amplified DNA assay (ADA) is rapid, is readily applicable to mass screening, and uses routine equipment. We show here that it can be used to detect human immunodeficiency virus sequences specifically against a background of human DNA.

  18. Synthesis and hybridization of a series of biotinylated oligonucleotides.

    PubMed Central

    Cook, A F; Vuocolo, E; Brakel, C L

    1988-01-01

    A series of oligonucleotides containing biotin-11-dUMP at various positions were synthesized and compared in quantitative, colorimetric hybridization-detection studies. A deoxyuridine phosphoramidite containing a protected allylamino sidearm was synthesized and used in standard, automated synthesis cycles to prepare oligonucleotides with allylamino residues at various positions within a standard 17-base sequence. Biotin substituents were subsequently attached to the allylamino sidearms by reaction with N-biotinyl-6-aminocaproic acid N-hydroxysuccinimide ester. These oligomers were hybridized to target DNA immobilized on microtiter wells (ELISA plates), and were detected with a streptavidin-biotinylated horseradish peroxidase complex using hydrogen peroxide as substrate and o-phenylenediamine as chromogen. We found that the sensitivity of detection of target DNA by biotin-labeled oligonucleotide probes was strongly dependent upon the position of the biotin label. Oligonucleotides containing biotin labels near or off the ends of the hybridizing sequence were more effective probes than oligonucleotides containing internal biotin labels. An additive effect of increasing numbers of biotin-dUMP residues was found for some labeling configurations. PMID:3375076

  19. [Phloretin induces apoptosis of BEL-7402 cells in vitro].

    PubMed

    Luo, Hui; Wang, Ya-jun; Chen, Jie; Liu, Jiang-qin; Zhang, Hai-tao

    2008-07-01

    To examine the effect of phloretin on apoptosis of BEL-7402 cells. The viability changes of BEL- 7402 cells as a result of phloretin-induced toxicity were analyzed using MTT assay, and the cell morphology changes were observed with fluorescence microscope. Flow cytometry was used to analyze the cell cycle and mitochondrial membrane potential changes, and chromogenic substrate assay performed to detect caspase activity. Phloretin induced obvious cytotoxicity against BEL-7402 cells with IC50 of 89.23 microg/mL. The growth curve demonstrated decreased growth of the cells as phloretin concentration increased. Cell apoptosis occurred 24 h after treatment with 40-160 microg/mL phloretin. Morphological, the cells exposed to phloretin exhibited nuclear chromatin condensation and increased fluorescence intensity. The activity of caspase-9 reached the peak level 12 h after phloretin exposure, and leak levels of caspase-6 and caspase-3 activities occurred 18 and 24 h after the exposure, respectively. Phloretin can induce BEL-7402 cell apoptosis though the mitochondrial pathway.

  20. Chromogenic detection of aminoglycoside phosphotransferases.

    PubMed

    Amoroso, A M; Gutkind, G O

    2001-01-01

    Acquired resistance to aminoglycosides is most frequently due to the presence of the so-called aminoglycoside modifying enzymes (AGME) (1) able to catalyze one or more of three general reactions: N-acetylation, O-nucleotidylation and O-phosphorylation (2). Although resistance phenotype (to different (substrate or not for enzymatic modification) may serve as an approach for identifying actual enzymes present in a given isolate (3), results can be obscured or confusing, particularly when several different enzymes (4) (even, isoenzymes with different affinities) are superimposing their action in a single microorganism with potential "permeability" or target alterations. Thus, identification of the AGME content of a given strain also requires screening at the DNA level using probes specific to all the known AGME (5). However, the complete set of probes is available only to a few laboratories around the world, making surveillance for the appearance of novel enzymes, or the unlikely evolution of those already known, a relatively nonfeasible goal, as search for new enzymes may begin only after failing to hybridize to all known probes.

  1. Characterization of the Annonaceous acetogenin, annonacinone, a natural product inhibitor of plasminogen activator inhibitor-1

    NASA Astrophysics Data System (ADS)

    Pautus, Stéphane; Alami, Mouad; Adam, Fréderic; Bernadat, Guillaume; Lawrence, Daniel A.; de Carvalho, Allan; Ferry, Gilles; Rupin, Alain; Hamze, Abdallah; Champy, Pierre; Bonneau, Natacha; Gloanec, Philippe; Peglion, Jean-Louis; Brion, Jean-Daniel; Bianchini, Elsa P.; Borgel, Delphine

    2016-11-01

    Plasminogen activator inhibitor-1 (PAI-1) is the main inhibitor of the tissue type and urokinase type plasminogen activators. High levels of PAI-1 are correlated with an increased risk of thrombotic events and several other pathologies. Despite several compounds with in vitro activity being developed, none of them are currently in clinical use. In this study, we evaluated a novel PAI-1 inhibitor, annonacinone, a natural product from the Annonaceous acetogenins group. Annonacinone was identified in a chromogenic screening assay and was more potent than tiplaxtinin. Annonacinone showed high potency ex vivo on thromboelastography and was able to potentiate the thrombolytic effect of tPA in vivo in a murine model. SDS-PAGE showed that annonacinone inhibited formation of PAI-1/tPA complex via enhancement of the substrate pathway. Mutagenesis and molecular dynamics allowed us to identify annonacinone binding site close to helix D and E and β-sheets 2A.

  2. Facile method to synthesize dopamine-capped mixed ferrite nanoparticles and their peroxidase-like activity

    NASA Astrophysics Data System (ADS)

    Mumtaz, Shazia; Wang, Li-Sheng; Abdullah, Muhammad; Zajif Hussain, Syed; Iqbal, Zafar; Rotello, Vincent M.; Hussain, Irshad

    2017-03-01

    A facile single-step strategy to prepare stable and water-dispersible dopamine-functionalized ultra-small mixed ferrite nanoparticles MFe2O4-DOPA (where M is a bivalent metal atom i.e. Fe, Co Cu, Mn and Ni) at room temperature is described. The nanoparticles formed have narrow size distribution as indicated by their characterization using transmission electron microscopy (TEM) and dynamic light scattering. The surface chemistry of these nanoparticles was probed by FTIR spectroscopy indicating their successful capping with dopamine ligands, which was further confirmed using zetapotential measurements and thermogravimetric analysis. The comparative horseradish peroxidase (HRP)—like activity of these cationic mixed ferrites nanoparticles was studied at pH 4.6 using a negatively-charged 2, 2‧-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS) as a chromogenic substrate in the presence of hydrogen peroxide. A time-dependent relative peroxidase-like activity follows the following order CoFe2O4-DOPA  >  MnFe2O4-DOPA  >  CuFe2O4-DOPA  >  NiFe2O4-DOPA  >  Fe3O4-DOPA. This diversity in HRP-like activity may be attributed to the different redox properties of ferrite nanoparticles when doped with M (Fe, Co Cu, Mn and Ni).

  3. Immunohistochemical analysis of the distribution of desmoglein 1 and 2 in the skin of dogs and cats.

    PubMed

    Miragliotta, Vincenzo; Coli, Alessandra; Ricciardi, Maria P; Podestà, Adriano; Abramo, Francesca

    2005-11-01

    To compare the distribution of desmoglein (Dsg) 1 and 2 in skin specimens obtained from dogs and cats to provide information about the possible role of the density of Dsg 1 and 2 in the localization of lesions attributable to pemphigus foliaceus in these 2 species. Skin biopsy specimens obtained from 4 dogs and 4 cats. Biopsy specimens were collected from the muzzle, bridge of the nose, ear, dorsum, abdomen, area adjacent to the teats, and footpads of each animal. Immunohistochemical analysis was performed on formalin-fixed, paraffin-embedded skin samples by use of a biotinylated mouse monoclonal anti-Dsg 1 and 2 antibody raised against bovine muzzle. Color development was performed by use of the streptavidin-biotin-peroxidase method with a chromogenic substrate. Immunohistochemical staining yielded a positive reaction in skin samples obtained from all anatomic sites. The intensity and distribution of staining were related to the number of layers of the stratum spinosum. No differences were detected between samples obtained from dogs and cats. No differences in intensity of Dsg 1 and 2 antigen were observed in the stratum spinosum between skin samples obtained from dogs and cats. Analysis of this result suggests that factors other than the distribution of Dsg may be responsible for the differences in localization of primary clinical lesions in dogs and cats with pemphigus foliaceus.

  4. [In vitro function of outer membrane protease T of Escherichia coli K1 pathogenic strain].

    PubMed

    Hui, Changye; Guo, Yan; Wu, Shuchi; Peng, Liang; Cao, Hong; Huang, Shenghe

    2010-01-01

    Plasminogen activation and antimicrobial peptide hydrolysis contribute to pathogens invasion and survival in vivo. To demonstrate the expression of outer membrane protease T in E. coli K1 pathogenic strain E44, its activity of plasminogen activator and protamine hydrolysis. After Benzamidine Sepharose Fast Flow and SOURCE 30Q chromatography, we got E44 outer membrane mixed fraction, and examined its activity of plasminogen activation with chromogenic substrate S-2251 method. An ompT deletion mutant of E44 was constructed by using the suicide vector pCVD442, termed as E44ompT. We examined 0.1 mg/mL cationic antimicrobial peptide protamine susceptibility of E44, ompT mutant strain E44ompT and E44ompT harboring pUCT, which was constructed by inserting complete ompT open reading frame into pUC13. We got about 37 kDa E44 membrane extract, which could activate plasminogen, and activation was membrane extract dose dependent. This confirmed the expression of outer membrane protease T in the outer membrane of E44. E44ompT was, more susceptible to 0.1 mg/mL protamine than E44, and E440mpT was partially complemented by pUCT. Outer membrane protease T is expressed in E. coli K1 pathogenic strain E44, and can activate plasminogen and hydrolyze protamine.

  5. Comparison of colorimetry and electrothermal atomic absorption spectroscopy for the quantification of non-transferrin bound iron in human sera.

    PubMed

    Jittangprasert, Piyada; Wilairat, Prapin; Pootrakul, Pensri

    2004-12-01

    This paper describes a comparison of two analytical techniques, one employing bathophenanthrolinedisulfonate (BPT), a most commonly-used reagent for Fe (II) determination, as chromogen and an electrothermal atomic absorption spectroscopy (ETAAS) for the quantification of non-transferrin bound iron (NTBI) in sera from thalassemic patients. Nitrilotriacetic acid (NTA) was employed as the ligand for binding iron from low molecular weight iron complexes present in the serum but without removing iron from the transferrin protein. After ultrafiltration the Fe (III)-NTA complex was then quantified by both methods. Kinetic study of the rate of the Fe (II)-BPT complex formation for various excess amounts of NTA ligand was also carried out. The kinetic data show that a minimum time duration (> 60 minutes) is necessary for complete complex formation when large excess of NTA is used. Calibration curves given by colorimetric and ETAAS methods were linear over the range of 0.15-20 microM iron (III). The colorimetric and ETAAS methods exhibited detection limit (3sigma) of 0.13 and 0.14 microM, respectively. The NTBI concentrations from 55 thalassemic serum samples measured employing BPT as chromogen were statistically compared with the results determined by ETAAS. No significant disagreement at 95% confidence level was observed. It is, therefore, possible to select any one of these two techniques for determination of NTBI in serum samples of thalassemic patients. However, the colorimetric procedure requires a longer analysis time because of a slow rate of exchange of NTA ligand with BPT, leading to the slow rate of formation of the colored complex.

  6. Enzyme actuated bioresponsive hydrogels

    NASA Astrophysics Data System (ADS)

    Wilson, Andrew Nolan

    Bioresponsive hydrogels are emerging with technological significance in targeted drug delivery, biosensors and regenerative medicine. Conferred with the ability to respond to specific biologically derived stimuli, the design challenge is in effectively linking the conferred biospecificity with an engineered response tailored to the needs of a particular application. Moreover, the fundamental phenomena governing the response must support an appropriate dynamic range and limit of detection. The design of these systems is inherently complicated due to the high interdependency of the governing phenomena that guide the sensing, transduction, and the actuation response of hydrogels. To investigate the dynamics of these materials, model systems may be used which seek to interrogate the system dynamics by uni-variable experimentation and limit confounding phenomena such as: polymer-solute interactions, polymer swelling dynamics and biomolecular reaction-diffusion concerns. To this end, a model system, alpha-chymotrypsin (Cht) (a protease) and a cleavable peptide-chromogen (pro-drug) covalently incorporated into a hydrogel, was investigated to understand the mechanisms of covalent loading and release by enzymatic cleavage in bio-responsive delivery systems. Using EDC and Sulfo-NHS, terminal carboxyl groups of N-succinyl-Ala-Ala-Pro-Phe p-nitroanilide, a cleavable chromogen, were conjugated to primary amines of a hydrated poly(HEMA)-based hydrogel. Hydrogel discs were incubated in buffered Cht causing enzyme-mediated cleavage of the peptide and concomitant release of the chromophore for monitoring. To investigate substrate loading and the effects of hydrogel morphology on the system, the concentration of the amino groups (5, 10, 20, and 30 mol%) and the cross-linked density (1, 5, 7, 9 and 12 mol%) were independently varied. Loading-Release Efficiency of the chromogen was shown to exhibit a positive relation to increasing amino groups (AEMA). The release rates demonstrated a negative relation to increasing cross-linked density attributed to decreasing void fractions and increasing tortuosities. The diffusion coefficient of Cht, D0, Cht, was determined to be 6.9 +/- 0.5 x 10-7 cm2 s -1, and the range of Deff of Cht for 1 to 12 mol% TEGDA was determined to 6.9 x10-8 to 0.1 x 10 -8cm2 s-1. We show how these parameters may be optimized and used to achieve programmed release rates in engineered bio-responsive systems. The field of bioresponsive hydrogels is continuing to expand as the need for such materials persists. Future work will enable more control over the loading and release of therapeutic and diagnostic moieties. Continued research regarding in enzymatically actuated hydrogels will involve pre-polymerization loading methodologies; in silico diffusion-reaction multiphysics modeling; enzyme actuated degradation of the polymer; and substation of various mediating enzyme, cleavable peptides, and release molecules.

  7. Enzymatic activities and effects of mycovirus infection on the virulence of Metarhizium anisopliae in Rhipicephalus microplus.

    PubMed

    Perinotto, Wendell M S; Golo, Patricia S; Coutinho Rodrigues, Caio J B; Sá, Fillipe A; Santi, Lucélia; Beys da Silva, Walter O; Junges, Angela; Vainstein, Marilene H; Schrank, Augusto; Salles, Cristiane M C; Bittencourt, Vânia R E P

    2014-06-16

    The present study aimed to evaluate the pathogenic potential of different Metarhizium anisopliae s.l. isolates and to determine whether differences in enzymatic activities of proteases, lipases and chitinases and infection with mycoviruses affect the control of Rhipicephalus microplus achieved by these fungal isolates. Engorged female ticks were exposed to fungal suspensions. The lipolytic and proteolytic activities in the isolates were evaluated using chromogenic substrates and the chitinolytic activity was determined using fluorescent substrates. A gel zymography was performed to determine the approximate size of serine proteases released by M. anisopliae isolates. To detect mycoviral infections, dsRNA was digested using both RNAse A and S1 endonuclease; samples were analyzed on an agarose gel. Four of the five isolates tested were infected with mycovirus; however, the level of control of R. microplus ticks achieved with the only isolate free of infection (isolate CG 347) was low. This finding suggests that mycoviral infection does not affect the virulence of fungi against ticks. Although all five isolates were considered pathogenic to R. microplus, the best tick control and the highest levels of enzymatic activity were achieved with the isolates CG 629 and CG 148. The in vitro activities of lipases, proteases and chitinases produced by M. anisopliae s.l. differed among isolates and may be related to their virulence. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Sulfated, low-molecular-weight lignins are potent inhibitorsof plasmin, in addition to thrombin and factor Xa: Novel opportunity for controlling complex pathologies.

    PubMed

    Henry, Brian L; Abdel Aziz, May; Zhou, Qibing; Desai, Umesh R

    2010-03-01

    Recently we prepared sulfated, low-molecular-weight lignins (LMWLs) to mimic the biological activities of heparin and heparan sulfate. Chemo-enzymatically prepared sulfated LMWLs represent a library of diverse non-sugar, aromatic molecules with structures radically different from the heparins, and have been found to potently inhibit thrombin and factor Xa. To assess their effect on the fibrinolytic system, we studied the interaction of LMWLs with human plasmin. Enzyme inhibition studies indicate that the three sulfated LMWLs studied inhibit plasmin with IC50 values in the range of 0.24 and 1.3 mM, which are marginally affected in the presence of antithrombin. Similarly, plasmin degradation of polymeric fibrin is also inhibited by sulfated LMWLs. Michaelis-Menten kinetic studies indicate that maximal velocity of hydrolysis of chromogenic substrates decreases nearly 70% in the presence of LMWLs, while the effect on Michaelis constant is dependent on the nature of the substrate. Competitive binding studies indicate that the sulfated LMWLs compete with full-length heparin. Comparison with thrombin-heparin crystal structure identifies an anionic region on plasmin as a plausible sulfated LMWL binding site. Overall, the chemo-enzymatic origin coupled with coagulation and fibrinolysis inhibition properties of sulfated LMWLs present novel opportunities for designing new pharmaceutical agents that regulate complex pathologies in which both systems are known to play important roles such as disseminated intravascular coagulation.

  9. EQCM Immunoassay for Phosphorylated Acetylcholinesterase as a Biomarker for Organophosphate Exposures Based on Selective Zirconia Adsorption and Enzyme-Catalytic Precipitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hua; Wang, Jun; Choi, Daiwon

    2009-03-01

    A zirconia (ZrO2) adsorption-based immunoassay by electrochemical quartz crystal microbalance (EQCM) has been initially developed, aiming at the detection of phosphorylated acetylcholinesterase (AChE) as a potential biomarker for bio-monitoring exposures to organophosphate (OP) pesticides and chemical warfare agents. Hydroxyl-derivatized monolayer was preferably chosen to modify the crystal serving as the template for directing the electro-deposition of ZrO2 film with uniform nanostructures. The resulting ZrO2 film was utilized to selectively capture phosphorylated AChE from the sample media. Horseradish peroxidase (HRP)-labeled anti-AChE antibodies were further employed to recognize the captured phosphorylated protein. Enzyme-catalytic oxidation of the benzidine substrate resulted in the accumulationmore » of insoluble product on the functionalized crystal. Ultrasensitive EQCM quantification by mass-amplified frequency responses as well as rapid qualification by visual color changes of product could be thus achieved. Moreover, 4-chloro-1-naphthol (CN) was comparably studied as an ideal chromogenic substrate for the enzyme-catalytic precipitation. Experimental results show that the developed EQCM technique can allow for the detection of phosphorylated AChE in human plasma. Such an EQCM immunosensing format opens a new door towards the development of simple, sensitive, and field-applicable biosensor for biologically monitoring low-level OP exposures.« less

  10. Isolation and characterization of acetamiprid - A neonicotinoid insecticide using TLC and GC-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Purohit, Praveen; Malik, Shaloo

    2018-05-01

    Neonicotinoid is a recently developed class of insecticides with worldwide use that has been increasing. It acts as a nicotinic acetylcholine receptor agonist. Acetamiprid belongs to this new class of insecticide which have different effects from other insecticides. The present paper deals with a method of extraction and isolation of Acetamiprid from cadaver tissues in a case of poisoning. TLC method using single solvent system and nine different chromogenic reagents has been suggested for preliminary identification. GC-mass spectrometry has been suggested to ascertain the presence of this neonicotinoid insecticide in the biological material for the use of working forensic toxicologists in the field.

  11. Hyperspectral imaging for presumptive identification of bacterial colonies on solid chromogenic culture media

    NASA Astrophysics Data System (ADS)

    Guillemot, Mathilde; Midahuen, Rony; Archeny, Delpine; Fulchiron, Corine; Montvernay, Regis; Perrin, Guillaume; Leroux, Denis F.

    2016-04-01

    BioMérieux is automating the microbiology laboratory in order to reduce cost (less manpower and consumables), to improve performance (increased sensitivity, machine algorithms) and to gain traceability through optimization of the clinical laboratory workflow. In this study, we evaluate the potential of Hyperspectral imaging (HSI) as a substitute to human visual observation when performing the task of microbiological culture interpretation. Microbial colonies from 19 strains subcategorized in 6 chromogenic classes were analyzed after a 24h-growth on a chromogenic culture medium (chromID® CPS Elite, bioMérieux, France). The HSI analysis was performed in the VNIR region (400-900 nm) using a linescan configuration. Using algorithms relying on Linear Spectral Unmixing, and using exclusively Diffuse Reflectance Spectra (DRS) as input data, we report interclass classification accuracies of 100% using a fully automatable approach and no use of morphological information. In order to eventually simplify the instrument, the performance of degraded DRS was also evaluated using only the most discriminant 14 spectral channels (a model for a multispectral approach) or 3 channels (model of a RGB image). The overall classification performance remains unchanged for our multispectral model but is degraded for the predicted RGB model, hints that a multispectral solution might bring the answer for an improved colony recognition.

  12. Performance of the Chromogenic Medium CHROMagar Staph Aureus and the Staphychrom Coagulase Test in the Detection and Identification of Staphylococcus aureus in Clinical Specimens

    PubMed Central

    Carricajo, Anne; Treny, Axel; Fonsale, Nathalie; Bes, Michele; Reverdy, Marie Elisabeth; Gille, Yves; Aubert, Gerald; Freydiere, Anne Marie

    2001-01-01

    CHROMagar Staph aureus (CSAM) (CHROMagar Microbiology, Paris, France) is a new chromogenic medium designed to enable detection of colonies of Staphylococcus aureus by their pink color. A total of 775 specimens were cultured in parallel on CHROMagar Staph aureus and conventional media. Among the 267 S. aureus strains recovered on at least one medium, 263 were isolated on CSAM medium (sensitivity, 98.5%), and 245 (sensitivity, 91.8%) were isolated on conventional media. The specificity of presumptive identification of S. aureus on the basis of pink colony color on CSAM medium was 97% (493 of 508). This specificity increased to 100% when coagulase detection with the Staphychrom coagulase test was added and to 98.8% when S. aureus surface components were detected by agglutination in the Pastorex Staph Plus test. Susceptibility testing of 67 S. aureus strains, performed in parallel on pink CSAM colonies and on colonies grown on blood agar, gave similar results. Thus, rapid and accurate recognition and identification of S. aureus isolates were achieved with CSAM as the primary isolation medium, followed by the staphylocoagulase Staphychrom test. Antimicrobial susceptibility testing (disk-diffusion method or ATB STAPH System) can be performed directly on pink CSAM colonies. PMID:11427572

  13. Comparison of four chromogenic media and Hektoen agar for detection and presumptive identification of Salmonella strains in human stools.

    PubMed

    Perez, J M; Cavalli, P; Roure, C; Renac, R; Gille, Y; Freydiere, A M

    2003-03-01

    Several chromogenic media have been developed to enhance the specificity of Salmonella detection. We compared the performance of four commercial chromogenic media-namely, ABC medium (Lab M. Ltd., Bury, United Kingdom), COMPASS Salmonella agar (Biokar Diagnostics, Beauvais, France), CHROMagar Salmonella agar (CHROMagar Company, Paris, France), and SM ID agar (bioMerieux, Marcy l'Etoile, France)-with conventional Hektoen medium. Nine hundred sixteen stool samples from inpatients at three hospitals were cultured, in parallel, on the five media, both by direct inoculation and after selective enrichment in selenite broth. Sixty-four Salmonella strains with 12 serotypes were isolated on at least one medium. After 48 h of incubation, sensitivity before and after enrichment was 62.5 and 89.1% with ABC medium, 77.1 and 93.8% with COMPASS agar, 66.7 and 89.1% with CHROMagar, 68.8 and 85.9% with SM ID agar, and 85.4 and 98.4% with Hektoen agar, respectively. Broth enrichment and prolonged incubation (48 versus 24 h) increased the sensitivity of all five media. Only one strain was not isolated on Hektoen agar. The number of false-positive isolates was higher with all five media after enrichment in selenite broth and after incubation for 48 h compared to 24 h. The specificity of the four chromogenic media was better than 91% after incubation for 24 h (77.7% with Hektoen agar) and better than 84% after incubation for 48 h (74.8% with Hektoen agar). This higher specificity reduces the need for confirmatory tests, thereby cutting technical time and reagent requirements. Both COMPASS agar and CHROMagar Salmonella, which after simple additional tests showed close efficiencies (96 and 97%, respectively), can be recommended as single-plate media of choice for the detection and presumptive identification of salmonellae in stools.

  14. Quantitative Assessment of the Heterogeneity of PD-L1 Expression in Non-Small-Cell Lung Cancer.

    PubMed

    McLaughlin, Joseph; Han, Gang; Schalper, Kurt A; Carvajal-Hausdorf, Daniel; Pelekanou, Vasiliki; Rehman, Jamaal; Velcheti, Vamsidhar; Herbst, Roy; LoRusso, Patricia; Rimm, David L

    2016-01-01

    Early-phase trials with monoclonal antibodies targeting PD-1 (programmed cell death protein 1) and PD-L1 (programmed cell death 1 ligand 1) have demonstrated durable clinical responses in patients with non-small-cell lung cancer (NSCLC). However, current assays for the prognostic and/or predictive role of tumor PD-L1 expression are not standardized with respect to either quantity or distribution of expression. To demonstrate PD-L1 protein distribution in NSCLC tumors using both conventional immunohistochemistry (IHC) and quantitative immunofluorescence (QIF) and compare results obtained using 2 different PD-L1 antibodies. PD-L1 was measured using E1L3N and SP142, 2 rabbit monoclonal antibodies, in 49 NSCLC whole-tissue sections and a corresponding tissue microarray with the same 49 cases. Non-small-cell lung cancer biopsy specimens from 2011 to 2012 were collected retrospectively from the Yale Thoracic Oncology Program Tissue Bank. Human melanoma Mel 624 cells stably transfected with PD-L1 as well as Mel 624 parental cells, and human term placenta whole tissue sections were used as controls and for antibody validation. PD-L1 protein expression in tumor and stroma was assessed using chromogenic IHC and the AQUA (Automated Quantitative Analysis) method of QIF. Tumor-infiltrating lymphocytes (TILs) were scored in hematoxylin-eosin slides using current consensus guidelines. The association between PD-L1 protein expression, TILs, and clinicopathological features were determined. PD-L1 expression discordance or heterogeneity using the diaminobenzidine chromogen and QIF was the main outcome measure selected prior to performing the study. Using chromogenic IHC, both antibodies showed fair to poor concordance. The PD-L1 antibodies showed poor concordance (Cohen κ range, 0.124-0.340) using conventional chromogenic IHC and showed intra-assay heterogeneity (E1L3N coefficient of variation [CV], 6.75%-75.24%; SP142 CV, 12.17%-109.61%) and significant interassay discordance using QIF (26.6%). Quantitative immunofluorescence showed that PD-L1 expression using both PD-L1 antibodies was heterogeneous. Using QIF, the scores obtained with E1L3N and SP142 for each tumor were significantly different according to nonparametric paired test (P < .001). Assessment of 588 serial section fields of view from whole tissue showed discordant expression at a frequency of 25%. Expression of PD-L1 was correlated with high TILs using both E1L3N (P = .007) and SP142 (P = .02). Objective determination of PD-L1 protein levels in NSCLC reveals heterogeneity within tumors and prominent interassay variability or discordance. This could be due to different antibody affinities, limited specificity, or distinct target epitopes. Efforts to determine the clinical value of these observations are under way.

  15. Liquid crystal cells with built-in CdSe nanotubes for chromogenic smart emission devices.

    PubMed

    Lin, Tsung Ju; Chen, Chin-Chang; Cheng, Soofin; Chen, Yang Fang

    2008-01-21

    A simple and general approach for controlling optical anisotropy of nanostructured semiconductors is reported. Our design involves the fabrication of liquid crystal devices with built-in semiconductor nanotubes. Quite interestingly, it is found that semiconductor nanotubes can be well aligned along the orientation of liquid crystals molecules automatically, resulting in a very large emission anisotropy with the degree of polarization up to 72%. This intriguing result manifests a way to obtain well aligned semiconductor nanotubes and the emission anisotropy can be easily manipulated by an external bias. The ability to well control the emission anisotropy should open up new opportunities for nanostructured semiconductors, including optical filters, polarized light emitting diodes, flat panel displays, and many other chromogenic smart devices.

  16. Development of an reliable analytical method for synergistic extractive spectrophotometric determination of cobalt(II) from alloys and nano composite samples by using chromogenic chelating ligand

    NASA Astrophysics Data System (ADS)

    Kamble, Ganesh S.; Ghare, Anita A.; Kolekar, Sanjay S.; Han, Sung H.; Anuse, Mansing A.

    2011-12-01

    A synergistic simple and selective spectrophotometric method was developed for the determination of cobalt(II) with 1-(2',4'-dinitro aminophenyl)-4,4,6-trimethyl-1,4-dihydropyrimidine-2-thiol [2',4'-dinitro APTPT] as a chromogenic reagent. The proposed method has been described on the basis of synergistic effective extraction of cobalt(II) in presence of pyridine at pH range 9.5-10.2, showed orange-red coloured ternary complex having molar ratio 1:2:2 (M:L:Py). The equilibrium time is 10 min for extraction of cobalt(III) from organic phase. The absorbance of coloured organic layer in chloroform is measured spectrophotometrically at 490 nm against reagent blank. The Beer's law was obeyed in the concentration range 2.5-15 μg mL -1 of cobalt(II) and optimum concentration range was 5-12.5 μg mL -1 of cobalt(II) and it was evaluated from Ringbom's plot. The molar absorptivity and Sandell's sensitivity of cobalt(II)-2',4'-dinitro APTPT-pyridine complex in chloroform are 1.109 × 10 3 L mol -1 cm -1 and 0.053 μg cm -2, respectively while molar absorptivity and Sandell's sensitivity of cobalt(II)-2',4'-dinitro APTPT complex in chloroform are 6.22 × 10 2 L mol -1 cm -1 and 0.096 μg cm -2, respectively. The composition of cobalt(II)-2',4'-dinitro APTPT-pyridine complex (1:2:2) was established by slope ratio method, mole ratio method and Job's method of continuous variation. The ternary complex was stable for more than 48 h. The interfering effects of various cations and anions were also studied, and use of suitable masking agents enhances the selectivity of the method. The method is successfully applied for the determination of cobalt(II) in binary, synthetic mixtures and real samples. A repetition of the method was checked by finding relative standard deviation (R.S.D.) for n = 5 which was 0.15%. The reliability of the method is confirmed by comparison of experimental results with atomic absorption spectrophotometer.

  17. Combinatorial Screening Of Inorganic And Organometallic Materials

    DOEpatents

    Li, Yi , Li, Jing , Britton, Ted W.

    2002-06-25

    A method for differentiating and enumerating nucleated red blood cells in a blood sample is described. The method includes the steps of lysing red blood cells of a blood sample with a lytic reagent, measuring nucleated blood cells by DC impedance measurement in a non-focused flow aperture, differentiating nucleated red blood cells from other cell types, and reporting nucleated red blood cells in the blood sample. The method further includes subtracting nucleated red blood cells and other interference materials from the count of remaining blood cells, and reporting a corrected white blood cell count of the blood sample. Additionally, the method further includes measuring spectrophotometric absorbance of the sample mixture at a predetermined wavelength of a hemoglobin chromogen formed upon lysing the blood sample, and reporting hemoglobin concentration of the blood sample.

  18. An automated sequential injection analysis system for the determination of trace endotoxin levels in water.

    PubMed

    Samanta, Gautam; Zhang, Shuming; Dasgupta, Purnendu

    2003-01-01

    A new automated instrument based on the Limulus amebocyte lysate (LAL)-chromogenic substrate kinetic assay for the determination of bacterial endotoxins is reported. A computer controlled syringe pump-multiport valve combination was used to aspirate the sample and other reagents into a holding coil. The syringe was always filled with air; liquid did not enter the syringe. The valve could address up to four individual radial paths, fully referenced optical fiber LED-based absorbance detectors that were housed collectively in a single, small (20 x 20 x 30 mm) metal block with a heater and temperature sensor, and maintained at 37 degrees C. Assay mixtures containing sample or standards were delivered to the individual detector cells for the simultaneous collection of the time based absorbance data. The automated system determined endotoxins with good accuracy and reproducibility in the range of 0.005-0.5 endotoxin units (EU)/mL (r2 > or = 0.99). Based on three times the standard deviation of the blank and the slope of the calibration curve, the lower limit of detection was < or = 0.003 EU/mL. The variability of the assay method is less than 5% (n = 10). Analysis time required for a 0.005 EU/mL standard was <100 min. Appropriately diluted tap water samples were simultaneously analyzed by the present system and a manually loaded commercial microplate reader based instrument; the data were statistically indistinguishable at the 95% confidence level.

  19. [Study on extraction of the total saponins of Chinese yam].

    PubMed

    Zhang, Min; Du, Lin; Huang, Gui-dong; Zhong, Xian-feng

    2007-07-01

    A method for the determination of total saponins of Chinese yam was established. The dioscin was used as a standard compound, the vanillin-perchloric acid as chromogenic agent and glacial acetic acid as solvent. The extraction technique of asponins from Chinese yam was studied by spectrometric method. Extracting temperature, extracting time, ethanol concentration and the ratio of raw material and water were selected as four factors to design the orthogonal test, and the optical condition of extraction was obtained. The results showed that the optical condition of extraction was as following: extracting temperature 60 degrees C, extracting time 6 h, ethanol concetration 80%, and the ratio of raw material and water 1:8.

  20. A new chromogenic medium for isolation of Bacteroides fragilis suitable for screening for strains with antimicrobial resistance.

    PubMed

    Tierney, Daniel; Copsey, Sarah D; Morris, Trefor; Perry, John D

    2016-06-01

    There have been an increasing number of reports describing the acquisition of antimicrobial resistance by Bacteroides fragilis including the occurrence of strains with resistance to multiple antimicrobials that are relied upon for treatment of infections. The aim of this study was to design a chromogenic selective medium for isolation of B. fragilis that could be adapted for specific isolation of antimicrobial-resistant strains. Bacteroides chromogenic agar (BCA) was the result of this endeavour and allowed growth of Bacteroides spp. as black colonies and the efficient inhibition of almost all other genera tested. The medium also allowed some differentiation of B. fragilis from other members of the B. fragilis group. When compared with an adaptation of Bacteroides bile-esculin agar (BBE) for the isolation of B. fragilis from 100 stool samples, 30 isolates of B. fragilis were recovered on BCA compared with 19 isolates recovered on BBE (P = 0.022). When supplemented with meropenem (4 μg/ml) or metronidazole (2 μg/ml), BCA could be used to select for the growth of B. fragilis isolates with resistance to these agents. We conclude that BCA is a useful research tool for surveillance studies to assess the prevalence of B. fragilis and, in particular, the occurrence of antimicrobial-resistant strains. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. A Pilot Demonstration of Electrochromic and Thermochromic Windows in the Denver Federal Center, Building 41, Denver, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Eleanor S.; Fernandes, Luis L.; Goudey, Chad Howdy

    Chromogenic glazing materials are emerging technologies that tint reversibly from a clear to dark tinted state either passively in response to environmental conditions or actively in response to a command from a switch or building automation system. Switchable coatings on glass manage solar radiation and visible light while enabling unobstructed views to the outdoors. Building energy simulations estimate that actively controlled, near-term chromogenic glazings can reduce perimeter zone heating, ventilation, and airconditioning (HVAC) and lighting energy use by 10-20% and reduce peak electricity demand by 20-30%, achieving energy use levels that are lower than an opaque, insulated wall. This projectmore » demonstrates the use of two types of chromogenic windows: thermochromic and electrochromic windows. By 2013, these windows will begin production in the U.S. by multiple vendors at high-volume manufacturing plants, enabling lower cost and larger area window products to be specified. Both technologies are in the late R&D stage of development, where cost reductions and performance improvements are underway. Electrochromic windows have been installed in numerous buildings over the past four years, but monitored energy-efficiency performance has been independently evaluated in very limited applications. Thermochromic windows have been installed in one other building with an independent evaluation, but results have not yet been made public.« less

  2. Using an AMACR (P504S)/34betaE12/p63 cocktail for the detection of small focal prostate carcinoma in needle biopsy specimens.

    PubMed

    Jiang, Zhong; Li, Cuizhen; Fischer, Andrew; Dresser, Karen; Woda, Bruce A

    2005-02-01

    We assessed the usefulness of immunohistochemical analysis with a 3-antibody cocktail (alpha-methylacyl coenzyme A racemase [AMACR, or P504S], 34betaE12, p63) and a double-chromogen reaction for detection of limited prostate cancer in 138 needle biopsy specimens, including 82 with small foci of prostatic adenocarcinoma and 56 benign prostates. When carcinoma was present, red cytoplasmic granular staining (AMACR) in the malignant glands and cells and dark brown nuclear (p63) and cytoplasmic (34betaE12) staining in basal cells of adjacent nonmalignant glands were found. Of 82 cases of small foci of prostatic adenocarcinoma, 78 (95%) expressed AMACR; all malignant glands were negative for basal cell staining. All benign glands adjacent to malignant glands were recognized easily by basal cell marker positivity and little or no AMACR expression. No benign glands were simultaneously positive for AMACR and negative for basal cell markers (specificity, 100%). There were no differences in intensity and numbers of positive glands with double-chromogen staining compared with using 1-color staining. Our results indicate that immunohistochemistry with a 3-antibody cocktail and double chromogen is a simple and easy assay that can be used as a routine test, which overcomes the problems of studying small lesions in prostate needle biopsies with multiple immunohistochemical stains.

  3. Assessment of Relative Bioavailability of Moroctocog Alfa and Moroctocog Alfa (AF-CC) in Subjects With Severe Hemophilia A.

    PubMed

    Korth-Bradley, Joan; Rupon, Jeremy; Plotka, Anna; Charnigo, Robert; Rendo, Pablo

    2018-05-01

    An open-label, single-dose, randomized, two-period, crossover study comparing the pharmacokinetics of factor VIII activity in plasma (FVIII:C) after administration of an albumin-free presentation of moroctocog alfa (test) and moroctocog alfa manufactured using the previous technique (reference) was conducted in 30 (25 evaluable) male subjects who had severe hemophilia A (FVIII:C < 1 IU/dL). Blood samples were collected for 48 h after administration of each dose. C was assayed using a chromogenic substrate assay. The FVIII:C pharmacokinetic parameters were calculated using noncompartmental analysis. The presentations would be bioequivalent if the 90% confidence limits of the ratio of the geometric mean values of AUC inf and recovery fell within the interval of 80-125%. The bioequivalence criteria were met. A total of 10 treatment-related adverse events were observed in a total of nine subjects. All were mild and none was determined to be related to administration of study medication. © 2018 The Authors. Clinical and Translational Science published by Wiley Periodicals, Inc. on behalf of American Society for Clinical Pharmacology and Therapeutics.

  4. Evaluation of thrombin inhibitory activity of catechins by online capillary electrophoresis-based immobilized enzyme microreactor and molecular docking.

    PubMed

    Li, Qiao-Qiao; Yang, Feng-Qing; Wang, Yin-Zhen; Wu, Zhao-Yu; Xia, Zhi-Ning; Chen, Hua

    2018-08-01

    An online capillary electrophoresis (CE)-based thrombin (THR) immobilized enzyme microreactor (IMER) method was established to screen THR inhibitors in this study. S-2366 was used as chromogenic substrate for determination of THR activity and other kinetic constants. After continuously run for 50 times, the prepared IMER could still remain 89% of the initial immobilized enzyme activity. The Michaelis-Menten constant (K m ) of immobilized THR was measured as 0.514 mmol/L and the half-maximal inhibitory concentration (IC 50 ) and inhibition constant (K i ) of argatroban on THR were determined as 78.07 and 26.53 nmol/L, respectively, which indicated that CE-based THR IMER was successfully established and could be applied to screen THR inhibitors. Then the prepared IMER was used to investigate the inhibitory potency on THR of four main catechins in green tea including epicatechin (EC), epigallocatechin (EGC), epicatechin gallate (ECG), and epigallocatechin gallate (EGCG). The results showed that ECG and EGCG had good THR inhibition activity and their inhibition rates at concentration of 200 μmol/L were 53.2 ± 3.8% and 55.8 ± 2.6%, respectively, which was in consistent with the results of microplate reader assay. Additionally, molecular docking results showed that the benzopyran groups of ECG and EGCG were inserted into the THR active pocket and interacted with residues LYS60F, TRP60D, TRY60A, IEU99, GLY216, HIS57 and SER195, but EC and EGC did not. Therefore, the developed CE-based THR IMER is reliable method for measuring THR inhibitory activity of natural inhibitors. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Polymerase spiral reaction (PSR): a novel, visual isothermal amplification method for detection of canine parvovirus 2 genomic DNA.

    PubMed

    Gupta, Vikas; Chakravarti, Soumendu; Chander, Vishal; Majumder, Saurabh; Bhat, Shabir Ahmad; Gupta, Vivek Kumar; Nandi, Sukdeb

    2017-07-01

    Canine parvovirus-2 (CPV-2), which is ubiquitously distributed worldwide, causes severe and often fatal gastroenteritis in dogs. Accurate, differential and rapid diagnosis of canine parvoviral enteritis remains a challenge for clinicians. A recently developed isothermal amplification technique, polymerase spiral reaction (PSR), was optimized for the first time for a viral pathogen with reference recombinant plasmid standards from different CPV-2 antigenic variants (CPV-2, CPV-2a, CPV-2b and CPV-2c) and subsequently validated using clinical samples. Addition of chromogenic substrate SYBR Green I after the completion of the reaction resulted in bright green fluorescence in positive samples, while negative samples and a no-template control remained orange. These results were further substantiated through visualization of a laddering pattern of the PSR-amplified product in an agarose gel in positive cases and the absence of this pattern in no-template control and negative samples. The PSR assay was found to be highly specific, as it did not react with other putative canine pathogens (canine adenovirus 1 and canine distemper virus). The sensitivity of the newly developed PSR technique was compared with that of conventional PCR, real-time PCR and LAMP, using a serial tenfold dilution of canine parvovirus DNA. The detection limit of PSR was found to be at the femtogram level, which is comparable with that of real-time PCR and LAMP, which are ten times more sensitive than conventional PCR. The assay was validated using 90 clinical samples, of which 54 were found positive, while only 45 samples were positive in conventional PCR. This novel assay, which is fully compliant with the 'ASSURED' concept for disease diagnosis, provides a simple, rapid, specific, sensitive and cost-effective method for diagnosis of canine parvoviral enteritis in veterinary clinics.

  6. [Changes of cementum endotoxin levels in different teeth with periodontitis treated with root conditioning].

    PubMed

    Fu, Chang-Sheng; Liu, Rong-Sen; Luo, Yun; Ou, Long; Li, Ying-Chao; Zhang, Xian-Hua

    2017-04-01

    To observe the changes of endotoxin levels after different teeth with periodontitis were treated with different methods. METHODS: Six healthy premolars extracted for orthodontic reasons and 36 posterior teeth extracted due to severe periodontitis were selected. Each tooth was processed from two 4 mm×4 mm×1 mm cementum pieces 2 mm under the cementum-enamel junction, each tooth with periodontitis was numbered. Healthy teeth served as negative control group, one of the two tablets from each tooth with periodontitis was selected in the periodontitis group, which was not treated with root surface treatment. The remaining 36 teeth with periodontitis were randomly divided into 6 groups: SRP group, SRP + antimicrobial peptide A group , SRP + antimicrobial peptide B group, SRP + EDTA group, SRP + Er:YAG laser group and SRP + Nd:YAG laser group. Endotoxin concentration in each tooth was determined by chromogenic substrate limulus reagent. The endotoxin concentration in each tooth was recorded according to the serial number, and the changes of endotoxin concentration were calculated before and after treatment. SPSS17.0 software package was used to analyze the data. Compared with the teeth with periodontitis, endotoxin concentration decreased to varying degrees, there were significant differences in each treatment group(P<0.01). Compared with SRP group, endotoxin levels in SRP + antimicrobial peptide A group, SRP + antimicrobial peptide B group, SRP + Er:YAG laser group were significantly decreased(P<0.01). No significant difference decreased was from between SRP + EDTA group and SRP + Nd:YAG laser group(P>0.05). Treatment of teeth with periodontitis using different methods can decrease the level of endotoxin, and the treatment of periodontitis root surface with antimicrobial peptide A + SRP may be more effective.

  7. Extract of Aronia melanocarpa-modified hemostasis: in vitro studies.

    PubMed

    Sikora, Joanna; Markowicz-Piasecka, Magdalena; Broncel, Marlena; Mikiciuk-Olasik, Elżbieta

    2014-10-01

    Aronia melanocarpa has an extremely high content of procyanidins and anthocyanins. The multidirectional benefits of consumption of these berries are widely reported. Although numerous studies confirmed the influence of polyphenols on various stages of hemostasis, the exact mechanism of this phenomenon is not understood. The aim of our study was to evaluate the in vitro effect of A. melanocarpa extract on various parameters of hemostasis. Adenosine 5'-diphosphate (ADP)-induced aggregation was measured with turbidimetric method. Spontaneous and ADP-activated platelet adhesion were investigated using a colorimetric method. The global assay of coagulation and fibrinolysis was performed with the use of optical clotting and lysis (CL) test. Thrombin (0.5 IU/mL) and tissue plasminogen activator (60 ng/mL) were used to obtain a CL curve. The activity of thrombin and plasmin was determined by means of chromogenic substrate (S-2238, S-2251) RESULTS: The aronia extract contributed to the reduction in spontaneous and ADP-activated platelet adhesion. A significant increase in overall potential of CL as well as significant changes in key parameters of these processes (T t-thrombin time, F vo-initial plasma clotting velocity, and L max-maximum lysis) was reported. Chokeberry extract significantly inhibited the amidolytic activity of thrombin and plasmin. Our in vitro findings indicate a complex mechanism of influence of chokeberry polyphenols on platelet activity and the overall potential of CL. We confirmed that chokeberry inhibits the amidolytic activity of thrombin. It was demonstrated for the first time that chokeberry polyphenols inhibit the amidolytic activity of another serine protease, i.e., plasmin, which is the main fibrinolytic enzyme. Furthermore, our research points out a significant contribution of other plasma components and fibrinogen in the modulation of hemostasis by polyphenols.

  8. Dual origin of gut proteases in Formosan subterranean termites (Coptotermes formosanus Shiraki) (Isoptera: Rhinotermitidae).

    PubMed

    Sethi, Amit; Xue, Qing-Gang; La Peyre, Jerome F; Delatte, Jennifer; Husseneder, Claudia

    2011-07-01

    Cellulose digestion in lower termites, mediated by carbohydrases originating from both termite and endosymbionts, is well characterized. In contrast, limited information exists on gut proteases of lower termites, their origins and roles in termite nutrition. The objective of this study was to characterize gut proteases of the Formosan subterranean termite (Coptotermes formosanus Shiraki) (Isoptera: Rhinotermitidae). The protease activity of extracts from gut tissues (fore-, mid- and hindgut) and protozoa isolated from hindguts of termite workers was quantified using hide powder azure as a substrate and further characterized by zymography with gelatin SDS-PAGE. Midgut extracts showed the highest protease activity followed by the protozoa extracts. High level of protease activity was also detected in protozoa culture supernatants after 24 h incubation. Incubation of gut and protozoa extracts with class-specific protease inhibitors revealed that most of the proteases were serine proteases. All proteolytic bands identified after gelatin SDS-PAGE were also inhibited by serine protease inhibitors. Finally, incubation with chromogenic substrates indicated that extracts from fore- and hindgut tissues possessed proteases with almost exclusively trypsin-like activity while both midgut and protozoa extracts possessed proteases with trypsin-like and subtilisin/chymotrypsin-like activities. However, protozoa proteases were distinct from midgut proteases (with different molecular mass). Our results suggest that the Formosan subterranean termite not only produces endogenous proteases in its gut tissues, but also possesses proteases originating from its protozoan symbionts. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Naked eye and spectrophotometric detection of chromogenic insecticide in aquaculture using amine functionalized gold nanoparticles in the presence of major interferents

    NASA Astrophysics Data System (ADS)

    Loganathan, C.; John, S. Abraham

    2017-02-01

    Detection of a chromogenic insecticide, malachite green (MG) using 3,5-diamino-1,2,4-triazole capped gold nanoparticles (DAT-AuNPs) by both naked eye and spectrophotometry was described in this paper. The DAT-AuNPs were prepared by wet chemical method and show absorption maximum at 518 nm. The zeta potential of DAT-AuNPs was found to be - 39.9 mV, suggesting that one of the amine groups of DAT adsorbed on the surface of AuNPs and the other amine group stabilizes the AuNPs from aggregation. The wine red color DAT-AuNPs changes to violet while adding 25 μM MG whereas the absorption band at 518 nm was increased and shifted towards longer wavelength. However, addition of 70 μM MG leads to the aggregation of DAT-AuNPs. This is due to strong electrostatic interaction between ammonium ion of MG and the free amine group of DAT. Based on the color change and shift in SPR band, 25 and 5 μM MG can be easily detected by naked eye and spectrophotometry. The DAT-AuNPs show high selectivity towards MG even in the presence of 5000-fold higher concentrations of common interferents. The practical application was successfully demonstrated by determining MG in fish farm water.

  10. Determination of HER2 amplification in primary breast cancer using dual-colour chromogenic in situ hybridization is comparable to fluorescence in situ hybridization: a European multicentre study involving 168 specimens.

    PubMed

    García-Caballero, Tomás; Grabau, Dorthe; Green, Andrew R; Gregory, John; Schad, Arno; Kohlwes, Elke; Ellis, Ian O; Watts, Sarah; Mollerup, Jens

    2010-03-01

    Fluorescence in situ hybridization (FISH) can be used to reveal several genomic imbalances relevant to proper cancer diagnosis and to the correct treatment regime. However, FISH requires expensive and advanced fluorescence microscopes in addition to expertise in fluorescence microscopy. To determine whether a newly developed dual-colour chromogenic in situ hybridization (CISH) method is a suitable alternative to FISH, we analysed the human epidermal growth factor receptor 2 gene (HER2) amplification level of 168 breast cancer specimens using dual-colour CISH and FISH and compared the results. We found 100% agreement between HER2 status determined by FISH and dual-colour CISH. Furthermore, we observed that the time used to score slides was significantly reduced by 28% in dual-colour CISH compared with the FISH protocol. Concordance between HER2 protein status and dual-colour CISH or FISH was equally good with an overall agreement of 96.8%. Correlation between the HER2/centromere 17 gene ratios obtained with dual-colour CISH and FISH was highly significant with an overall correlation coefficient (rho) of 0.96. We conclude that dual-colour CISH and bright field microscopy are excellent alternatives to FISH when analysing the HER2 status of primary breast cancer.

  11. Evaluation of chromogenic medium and direct latex agglutination test for detection of group B streptococcus in vaginal specimens from pregnant women in Lebanon and Kuwait.

    PubMed

    Ghaddar, Nahed; Alfouzan, Wadha; Anastasiadis, Elie; Al Jiser, Tamima; Itani, Saad Eddine; Dernaika, Racha; Eid, Toufic; Ghaddar, Ali; Charafeddine, Adib; Dhar, Rita; El Hajj, Hiba

    2014-10-01

    This study was undertaken to evaluate chromogenic medium and a direct latex agglutination test (DLA) for detection of Group B Streptococcus (GBS) in the vaginal specimens of pregnant women, and to ascertain the prevalence of GBS in this population in Kuwait and Lebanon. Vaginal swabs, collected from women at 35-37 weeks of gestation, were cultured on 5 % sheep blood agar (SBA), colistin nalidixic acid agar (CNA), Strept B Select chromogenic agar (SBS) as well as Lim enrichment broth in 168 cases in Lebanon while only SBA was used for 1391 samples in Kuwait. In addition, vaginal samples from 102 GBS-positive and 20 GBS-negative women near the time of delivery were collected in Kuwait for evaluation of the DLA test. During the study period, the prevalence of GBS colonization was determined to be 20.7 % (288/1391) in Kuwait while 18.4 % (31) of 168 pregnant women in Lebanon had vaginal cultures positive for GBS. By direct plating of vaginal swabs on the three media used, the isolation rates of GBS were 51.6, 64.5 and 77.4 % on SBA, CNA and SBS, respectively, which increased to 90.35, 93.1 and 96.8 %, respectively, following subculture in Lim broth after 18 h of incubation. The sensitivity of the DLA test was found to be dependent on the density of GBS colonization, resulting in 100 % sensitivity and 100 % specificity for heavy (>10(2) c.f.u. per swab) and moderately heavy (50-100 c.f.u. per swab) growth of GBS. However, for vaginal specimens yielding <50 c.f.u. per swab, the sensitivity, specificity, positive and negative predictive values of the DLA test were 100, 55.5, 63.6 and 100 %, respectively. In conclusion, a chromogenic agar, such as SBS, and a DLA test can be used for rapid detection of GBS in pregnant women. The DLA test, in particular, could prove to be a useful tool for immediate detection of GBS in women near delivery so that intrapartum antibiotic prophylaxis can be initiated. © 2014 The Authors.

  12. Photodissociation of Non-Covalent Peptide-Crown Ether Complexes

    PubMed Central

    Wilson, Jeffrey J.; Kirkovits, Gregory J.; Sessler, Jonathan L.; Brodbelt, Jennifer S.

    2008-01-01

    Highly chromogenic 18-crown-6-dipyrrolylquinoxaline coordinates primary amines of peptides, forming non-covalent complexes that can be transferred to the gas phase by electrospray ionization. The appended chromogenic crown ether facilitates efficient energy transfer to the peptide upon ultraviolet irradiation in the gas phase, resulting in diagnostic peptide fragmentation. Collisional activated dissociation (CAD) and infrared multiphoton dissociation (IRMPD) of these non-covalent complexes results only in their disassembly with the charge retained on either the peptide or crown ether, yielding no sequence ions. Upon UV photon absorption the intermolecular energy transfer is facilitated by the fast activation time scale of UVPD (< 10 ns) and by the collectively strong hydrogen bonding between the crown ether and peptide, thus allowing effective transfer of energy to the peptide moiety prior to disruption of the intermolecular hydrogen bonds. PMID:18077179

  13. Cross-reacting Material-positive Hemophilia A Diagnosed in a Patient with a Spontaneous Thigh Hemorrhage

    PubMed Central

    Saito, Tatsuya; Mukae, Jyunichi; Nakamura, Yosuke; Inaba, Hiroshi; Nogami, Keiji; Koyama, Takatoshi; Fukutake, Katsuyuki; Yamamoto, Koh

    2017-01-01

    A 53-year-old man, who had been diagnosed with mild hemophilia A (HA) at 35 years of age, was hospitalized with a thigh hematoma. His bleeding continued despite the administration of recombinant factor VIII (FVIII). The results of an FVIII/von Willebrand factor binding assay were normal. The patient's FVIII coagulant activity (FVIII:C) was low, but his FVIII antigen levels were within the normal limits, suggesting FVIII protein dysfunction. The FVIII:C measurements obtained by one-stage clotting and chromogenic assays were different. An FVIII gene analysis revealed a missense mutation p.Ser308Leu, which is rare in Japan. This case highlights that gene analyses and chromogenic assays are necessary to interpret the discrepancies between FVIII:C and the bleeding phenotype of patients with mild HA. PMID:28674365

  14. Cross-reacting Material-positive Hemophilia A Diagnosed in a Patient with a Spontaneous Thigh Hemorrhage.

    PubMed

    Saito, Tatsuya; Mukae, Jyunichi; Nakamura, Yosuke; Inaba, Hiroshi; Nogami, Keiji; Koyama, Takatoshi; Fukutake, Katsuyuki; Yamamoto, Koh

    2017-01-01

    A 53-year-old man, who had been diagnosed with mild hemophilia A (HA) at 35 years of age, was hospitalized with a thigh hematoma. His bleeding continued despite the administration of recombinant factor VIII (FVIII). The results of an FVIII/von Willebrand factor binding assay were normal. The patient's FVIII coagulant activity (FVIII:C) was low, but his FVIII antigen levels were within the normal limits, suggesting FVIII protein dysfunction. The FVIII:C measurements obtained by one-stage clotting and chromogenic assays were different. An FVIII gene analysis revealed a missense mutation p.Ser308Leu, which is rare in Japan. This case highlights that gene analyses and chromogenic assays are necessary to interpret the discrepancies between FVIII:C and the bleeding phenotype of patients with mild HA.

  15. Accurate Detection of Adenylation Domain Functions in Nonribosomal Peptide Synthetases by an Enzyme-linked Immunosorbent Assay System Using Active Site-directed Probes for Adenylation Domains.

    PubMed

    Ishikawa, Fumihiro; Miyamoto, Kengo; Konno, Sho; Kasai, Shota; Kakeya, Hideaki

    2015-12-18

    A significant gap exists between protein engineering and enzymes used for the biosynthesis of natural products, largely because there is a paucity of strategies that rapidly detect active-site phenotypes of the enzymes with desired activities. Herein, we describe a proof-of-concept study of an enzyme-linked immunosorbent assay (ELISA) system for the adenylation (A) domains in nonribosomal peptide synthetases (NRPSs) using a combination of active site-directed probes coupled to a 5'-O-N-(aminoacyl)sulfamoyladenosine scaffold with a biotin functionality that immobilizes probe molecules onto a streptavidin-coated solid support. The recombinant NRPSs have a C-terminal His-tag motif that is targeted by an anti-6×His mouse antibody as the primary antibody and a horseradish peroxidase-linked goat antimouse antibody as the secondary antibody. These probes can selectively capture the cognate A domains by ligand-directed targeting. In addition, the ELISA technique detected A domains in the crude cell-free homogenates from the Escherichia coli expression systems. When coupled with a chromogenic substrate, the antibody-based ELISA technique can visualize probe-protein binding interactions, which provides accurate readouts of the A-domain functions in NRPS enzymes. To assess the ELISA-based engineering of the A domains of NRPSs, we reprogramed 2,3-dihydroxybenzoic acid (DHB)-activating enzyme EntE toward salicylic acid (Sal)-activating enzymes and investigated a correlation between binding properties for probe molecules and enzyme catalysts. We generated a mutant of EntE that displayed negligible loss in the kcat/Km value with the noncognate substrate Sal and a corresponding 48-fold decrease in the kcat/Km value with the cognate substrate DHB. The resulting 26-fold switch in substrate specificity was achieved by the replacement of a Ser residue in the active site of EntE with a Cys toward the nonribosomal codes of Sal-activating enzymes. Bringing a laboratory ELISA technique and adenylating enzymes together using a combination of active site-directed probes for the A domains in NRPSs should accelerate both the functional characterization and manipulation of the A domains in NRPSs.

  16. Flow-batch analysis of clenbuterol based on analyte extraction on molecularly imprinted polymers coupled to an in-system chromogenic reaction. Application to human urine and milk substitute samples.

    PubMed

    González, Natalia; Grünhut, Marcos; Šrámková, Ivana; Lista, Adriana G; Horstkotte, Burkhard; Solich, Petr; Sklenářová, Hana; Acebal, Carolina C

    2018-02-01

    A fully automated spectrophotometric method based on flow-batch analysis has been developed for the determination of clenbuterol including an on-line solid phase extraction using a molecularly imprinted polymer (MIP) as the sorbent. The molecularly imprinted solid phase extraction (MISPE) procedure allowed analyte extraction from complex matrices at low concentration levels and with high selectivity towards the analyte. The MISPE procedure was performed using a commercial MIP cartridge that was introduced into a guard column holder and integrated in the analyzer system. Optimized parameters included the volume of the sample, the type and volume of the conditioning and washing solutions, and the type and volume of the eluent. Quantification of clenbuterol was carried out by spectrophotometry after in-system post-elution analyte derivatization based on azo-coupling using N- (1-Naphthyl) ethylenediamine as the coupling agent to yield a red-colored compound with maximum absorbance at 500nm. Both the chromogenic reaction and spectrophotometric detection were performed in a lab-made flow-batch mixing chamber that replaced the cuvette holder of the spectrophotometer. The calibration curve was linear in the 0.075-0.500mgL -1 range with a correlation coefficient of 0.998. The precision of the proposed method was evaluated in terms of the relative standard deviation obtaining 1.1% and 3.0% for intra-day precision and inter-day precision, respectively. The detection limit was 0.021mgL -1 and the sample throughput for the entire process was 3.4h -1 . The proposed method was applied for the determination of CLB in human urine and milk substitute samples obtaining recoveries values within a range of 94.0-100.0%. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. An evaluation of the automated assay of urinary oestrogens in pregnant women

    PubMed Central

    Muir, G. G.; Ryan, M.; Conaill, D. U.

    1970-01-01

    An automated assay suitable for estimating urinary oestrogens in pregnant women has been investigated. Fluorimetry was found to have considerable advantages over colorimetry. The fluorimetric assay was simpler, more precise, more sensitive, and eliminated the need for correction for non-specific chromogens; in the assay of oestriol in pregnant women there was no need for correction for non-specific fluorescence. Spectrofluorimetric and photometric analyses, recoveries, and reproducibility show that the method offers a robust means of providing values for urinary oestrogen in pregnant women on a scale of up to 100 tests a day, the time of the assay being one and a half hours. PMID:5476876

  18. Simultaneous injection-effective mixing analysis of palladium.

    PubMed

    Teshima, Norio; Noguchi, Daisuke; Joichi, Yasutaka; Lenghor, Narong; Ohno, Noriko; Sakai, Tadao; Motomizu, Shoji

    2010-01-01

    A novel concept of simultaneous injection-effective mixing analysis (SIEMA) is proposed, and a SIEMA method applied to the spectrophotometric determination of palladium using a water-soluble chromogenic reagent has been demonstrated. The flow configuration of SIEMA is a hybrid format of flow injection analysis (FIA), sequential injection analysis (SIA) and multicommutation in flow-based analysis. Sample and reagent solutions are aspirated into each holding coil through each solenoid valve by a syringe pump, and then the zones are simultaneously dispensed (injected) into a mixing coil by reversed flow toward a detector through a confluence point. This results in effective mixing and rapid detection with low reagent consumption.

  19. A Fatal Case of Candida auris and Candida tropicalis Candidemia in Neutropenic Patient.

    PubMed

    Mohd Tap, Ratna; Lim, Teck Choon; Kamarudin, Nur Amalina; Ginsapu, Stephanie Jane; Abd Razak, Mohd Fuat; Ahmad, Norazah; Amran, Fairuz

    2018-06-01

    We report a fatal case of Candida auris that was involved in mixed candidemia with Candida tropicalis, isolated from the blood of a neutropenic patient. Identification of both isolates was confirmed by amplification and sequencing of internal transcribed spacer and D1/D2 domain of large subunit in rRNA gene. Antifungal susceptibility test by E-test method revealed that C. auris was resistant to amphotericin B, anidulafungin, caspofungin, fluconazole, itraconazole and voriconazole. On the other hand, C. tropicalis was sensitive to all antifungal tested. The use of chromogenic agar as isolation media is vital in detecting mixed candidemia.

  20. Effect of potentially chromogenic beverages on shear bond strength of acrylic denture teeth to heat-polymerized denture base resins

    PubMed Central

    Neppelenbroek, Karin Hermana; Urban, Vanessa Migliorini; de Oliveira, Denise Gusmão; Porto, Vinícius Carvalho; Almilhatti, Hercules Jorge; Campanha, Nara Hellen

    2016-01-01

    Background: Detachment of denture acrylic resin artificial teeth from denture base resin is one of the most common problems presented by denture wearers. Purpose: This study investigated the shear bond strength (SBS) and fracture type of bonding interface of two commercial acrylic teeth (Vipi Dent Plus e Biolux) to two denture base resins (Vipi Cril e Lucitone 550) after immersion in potentially chromogenic beverages (coffee, cola soft drink, and red wine) or control solution (distilled water). Materials and Methods: Maxillary central incisor acrylic teeth were placed at 45° to denture base resin and submitted to short polymerization cycle according to manufacturers. Specimens were divided according to the combination tooth/resin/solution (n = 8) and submitted to bond strength tests in a universal testing machine MTS-810 (0.5 mm/min). Subsequently, fracture area was analyzed by stereomicroscope at a magnification of ×10 and categorized into adhesive, cohesive, or mixed failure. Results: The bond strength of teeth/denture base resins interface was not significantly affected by tested solutions (P > 0.087), except for Biolux teeth immersed in coffee (P < 0.01). In all conditions, the Vipi Dent Plus teeth showed higher bond strength to Lucitone and Vipi Cril resins when compared to Biolux teeth (P < 0.003). All specimens’ failure modes were cohesive. Conclusions: The SBS of acrylic teeth to denture base resins was not generally influenced by immersion in the tested staining beverages. PMID:27621547

  1. Presumptive identification of Candida species other than C. albicans, C. krusei, and C. tropicalis with the chromogenic medium CHROMagar Candida

    PubMed Central

    Hospenthal, Duane R; Beckius, Miriam L; Floyd, Karon L; Horvath, Lynn L; Murray, Clinton K

    2006-01-01

    Background CHROMagar Candida (CaC) is increasingly being reported as a medium used to differentiate Candida albicans from non-albicans Candida (NAC) species. Rapid identification of NAC can assist the clinician in selecting appropriate antifungal therapy. CaC is a differential chromogenic medium designed to identify C. albicans, C. krusei, and C. tropicalis based on colony color and morphology. Some reports have proposed that CaC can also reliably identify C. dubliniensis and C. glabrata. Methods We evaluated the usefulness of CaC in the identification of C. dubliniensis, C. famata, C. firmetaria, C. glabrata, C. guilliermondii, C. inconspicua, C. kefyr, C. lipolytica, C. lusitaniae, C. norvegensis, C. parapsilosis, and C. rugosa. Results Most NAC produced colonies that were shades of pink, lavender, or ivory. Several isolates of C. firmetaria and all C. inconspicua produced colonies difficult to differentiate from C. krusei. Most C. rugosa isolates produced unique colonies with morphology like C. krusei except in a light blue-green color. C. glabrata isolates produced small dark violet colonies that could be differentiated from the pink and lavender colors produced by other species. All seventeen isolates of C. dubliniensis produced green colonies similar to those produced by C. albicans. Conclusion C. glabrata and C. rugosa appear distinguishable from other species using CaC. Some NAC, including C. firmetaria and C. inconspicua, could be confused with C. krusei using this medium. PMID:16390552

  2. Phenotypical and Genotypical Antimicrobial Resistance of Coagulase-negative staphylococci Isolated from Cow Mastitis.

    PubMed

    Klimiene, I; Virgailis, M; Pavilonis, A; Siugzdiniene, R; Mockeliunas, R; Ruzauskas, M

    2016-09-01

    The objectives of this study were to determine the prevalence and antimicrobial resistance of coagulase-negative staphylococci (CNS) isolated from dairy cows with subclinical mastitis. Antimicrobial resistance in staphylococci were evaluated by breakpoint values specific to the species (EU-CAST). The presence of resistance-encoding genes was detected by multiplex PCR. A total of 191 CNS isolates were obtained. The CNS isolates were typically resistant to penicillin (67.4%), tetracyc-line (18.9%), and erythromycin (13.7%). CNS isolates (78.0%) were resistant to at least one antimicrobial compound, and 22.0% were multiresistant. The multiresistant isolates were predominantly Staphylococcus chromogenes (28.6%), Staphylococcus warneri (19%) and Staphylococcus haemolyticus (14.3%). According to MIC pattern data, multiresistant isolates showed the highest resistance (p<0.05) rates to penicillin (85.7%), tetracycline (66.7%), and erythromycin (48.2%), but all of them were sensitive to daptomycin, oxacillin, qiunupristin/dalfopristin, and vancomycin. S. chromogenes (9.5%), S. haemolyticus (4.8%), and S. capitis ss capitis (2.4%) strains were resistant to methicillin; their resistance to oxacillin and penicillin was more than 8 mg/l. A high rate of resistance to penicillin was linked to a blaZ gene found in 66.6% of the isolated multiresistant CNS strains. Resistance to tetracycline via the tetK (38.1%) gene and penicillin via the mecA (23.8%) gene were detected less frequently. Gene msrAB was responsible for macrolides and lincosamides resistance and detected in 28.6% of the CNS isolates. Antimicrobial resistance genes were identified more frequently in S. epidermidis, S. chromogenes, and S. warneri.

  3. A competitive ELISA to detect brevetoxins from Karenia brevis (formerly Gymnodinium breve) in seawater, shellfish, and mammalian body fluid.

    PubMed Central

    Naar, Jerome; Bourdelais, Andrea; Tomas, Carmelo; Kubanek, Julia; Whitney, Philip L; Flewelling, Leanne; Steidinger, Karen; Lancaster, Johnny; Baden, Daniel G

    2002-01-01

    We developed a competitive enzyme-linked immunosorbent assay (ELISA) to analyze brevetoxins, using goat anti-brevetoxin antibodies obtained after immunization with keyhole limpet hemocyanin-brevetoxin conjugates, in combination with a three-step signal amplification process. The procedure, which used secondary biotinylated antibodies, streptavidine-horseradish peroxidase conjugate, and chromogenic enzyme substrate, was useful in reducing nonspecific background signals commonly observed with complex matrices. This competitive ELISA detected brevetoxins in seawater, shellfish extract and homogenate, and mammalian body fluid such as urine and serum without pretreatment, dilution, or purification. We investigated the application of this technique for shellfish monitoring by spiking shellfish meat with brevetoxins and by analyzing oysters from two commercial shellfish beds in Florida that were exposed to a bloom of Karenia brevis (formerly Gymnodinium breve). We performed brevetoxin analysis of shellfish extracts and homogenates by ELISA and compared it with the mouse bioassay and receptor binding assay. The detection limit for brevetoxins in spiked oysters was 2.5 microg/100 g shellfish meat. This assay appears to be a useful tool for neurotoxic shellfish poisoning monitoring in shellfish and seawater, and for mammalian exposure diagnostics, and significantly reduces the time required for analyses. PMID:11836147

  4. Dual-color plasmonic enzyme-linked immunosorbent assay based on enzyme-mediated etching of Au nanoparticles

    NASA Astrophysics Data System (ADS)

    Guo, Longhua; Xu, Shaohua; Ma, Xiaoming; Qiu, Bin; Lin, Zhenyu; Chen, Guonan

    2016-09-01

    Colorimetric enzyme-linked immunosorbent assay utilizing 3‧-3-5‧-5-tetramethylbenzidine(TMB) as the chromogenic substrate has been widely used in the hospital for the detection of all kinds of disease biomarkers. Herein, we demonstrate a strategy to change this single-color display into dual-color responses to improve the accuracy of visual inspection. Our investigation firstly reveals that oxidation state of 3‧-3-5‧-5-tetramethylbenzidine (TMB2+) can quantitatively etch gold nanoparticles. Therefore, the incorporation of gold nanoparticles into a commercial TMB-based ELISA kit could generate dual-color responses: the solution color varied gradually from wine red (absorption peak located at ~530 nm) to colorless, and then from colorless to yellow (absorption peak located at ~450 nm) with the increase amount of targets. These dual-color responses effectively improved the sensitivity as well as the accuracy of visual inspection. For example, the proposed dual-color plasmonic ELISA is demonstrated for the detection of prostate-specific antigen (PSA) in human serum with a visual limit of detection (LOD) as low as 0.0093 ng/mL.

  5. Technology assessment and strategy for development of a Rapid Field Water Microbiology Test Kit. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Preston, D.R.; Schaub, S.A.

    1991-09-01

    A literature and market search of existing technology for the detection, identification, and quantification of microorganisms in water was conducted. Based upon the availability of technologies and their configurations, an assessment of the appropriate strategies to pursue for the near and long term development plans in development of the Rapid Field Bacteriology Test Kit was performed. Near term technologies to improve the Army's capability to detect microorganisms would appear to be essentially improvements in versatility and measurement of coliform indicator organisms. New chromogenic and fluorogenic indicator substances associated with new substrates appear to be best suited for test kit developmentmore » either for quantitative membrane filter tests or presence/absence and multiple fermentation tests. Test times, incubator requirements, and operator involvement appear to be similar to older technologies. Long term development would appear to favor such technologies as genetic probes with amplification of the hydridized nucleic acid materials of positive samples, and some immunological based systems such as enzyme linked, immuno-sorbent assays. In both cases, the major problems would appear to be sample preparation and development of signal strengths from the reactions which would allow the user to see results in 1 hour.« less

  6. In vitro thrombolytic activity of purified streptokinase extracted from Streptococcus equinus VIT_VB2 isolated from bovine milk.

    PubMed

    Babu, Vaishnavi; Subathra Devi, C

    2015-01-01

    Streptokinase (SK) is an extracellular enzyme secreted by various strains of β-hemolytic Streptococci. The main focus of the current study is to evaluate the in vitro thrombolytic activity of purified SK extracted from Streptococcus equinus VIT_VB2 (Accession no. JX406835) isolated from milk sample. The growth rate of S. equinus VIT_VB2 strain was studied with pH and biomass content which has positive significant effect on enzyme yield. A temperature of 10 °C and pH of 6 was found to be optimum for maximum SK activity. The specific activity of the purified SK produced by VIT_VB2 strain was found to be 6,585 IU mg(-1). The molecular mass of the enzyme was determined as 47 kDa by SDS-PAGE. In vitro thrombolytic activity of purified SK was determined using synthetic chromogenic substrate S-2251, the activity of the purified enzyme was found to be 6,330 ± 2.2 IU. The purity of SK was compared with standard SK by HPLC. This is the first report which reveals the SK activity of S. equinus isolated from milk sample.

  7. Influence of spacer length on heparin coupling efficiency and fibrinogen adsorption of modified titanium surfaces

    PubMed Central

    Tebbe, David; Thull, Roger; Gbureck, Uwe

    2007-01-01

    Background Chemical bonding of the drug onto surfaces by means of spacer molecules is accompanied with a reduction of the biological activity of the drug due to a constricted mobility since normally only short spacer molecule like aminopropyltrimethoxysilane (APMS) are used for drug coupling. This work aimed to study covalent attachment of heparin to titanium(oxide) surfaces by varying the length of the silane coupling agent, which should affect the biological potency of the drug due to a higher mobility with longer spacer chains. Methods Covalent attachment of heparin to titanium metal and TiO2 powder was carried out using the coupling agents 3-(Trimethoxysilyl)-propylamine (APMS), N- [3-(Trimethoxysilyl)propyl]ethylenediamine (Diamino-APMS) and N1- [3-(Trimethoxy-silyl)-propyl]diethylenetriamine (Triamino-APMS). The amount of bound coupling agent and heparin was quantified photometrically by the ninhydrin reaction and the tolidine-blue test. The biological potency of heparin was determined photometrically by the chromogenic substrate Chromozym TH and fibrinogen adsorption to the modified surfaces was researched using the QCM-D (Quartz Crystal Microbalance with Dissipation Monitoring) technique. Results Zeta-potential measurements confirmed the successful coupling reaction; the potential of the unmodified anatase surface (approx. -26 mV) shifted into the positive range (> + 40 mV) after silanisation. Binding of heparin results in a strongly negatively charged surface with zeta-potentials of approx. -39 mV. The retaining biological activity of heparin was highest for the spacer molecule Triamino-APMS. QCM-D measurements showed a lower viscosity for adsorbed fibrinogen films on heparinised surfaces by means of Triamino-APMS. Conclusion The remaining activity of heparin was found to be highest for the covalent attachment with Triamino-APMS as coupling agent due to the long chain of this spacer molecule and therefore the highest mobility of the drug. Furthermore, the adsorption of fibrinogen on the differently heparinised surfaces in real time demonstrated that with longer spacer chains the ΔD/Δf ratios became higher, which is also associated with better biocompatible properties of the substrates in contact with a biosystem. PMID:17640335

  8. Substrate patterning with NiOx nanoparticles and hot-wire chemical vapour deposition of WO3x and carbon nanostructures

    NASA Astrophysics Data System (ADS)

    Houweling, Z. S.

    2011-10-01

    The first part of the thesis treats the formation of nickel catalyst nanoparticles. First, a patterning technique using colloids is employed to create ordered distributions of monodisperse nanoparticles. Second, nickel films are thermally dewetted, which produces mobile species that self-arrange in non-ordered distributions of polydisperse particles. Third, the mobility of the nickel species is successfully reduced by the addition of air during the dewetting and the use of a special anchoring layer. Thus, non-ordered distributions of self-arranged monodisperse nickel oxide nanoparticles (82±10 nm x 16±2 nm) are made. Studies on nickel thickness, dewetting time and dewetting temperature are conducted. With these particle templates, graphitic carbon nanotubes are synthesised using catalytic hot-wire chemical vapour deposition (HWCVD), demonstrating the high-temperature processability of the nanoparticles. The second part of this thesis treats the non-catalytic HWCVD of tungsten oxides (WO3-x). Resistively heated tungsten filaments exposed to an air flow at subatmospheric pressures, produce tungsten oxide vapour species, which are collected on substrates and are subsequently characterised. First, a complete study on the process conditions is conducted, whereby the effects of filament radiation, filament temperature, process gas pressure and substrate temperature, are investigated. The thus controlled growth of nanogranular smooth amorphous and crystalline WO3-x thin films is presented for the first time. Partially crystalline smooth hydrous WO3-x thin films consisting of 20 nm grains can be deposited at very high rates. The synthesis of ultrafine powders with particle sizes of about 7 nm and very high specific surface areas of 121.7±0.4 m2·g-1 at ultrahigh deposition rates of 36 µm·min-1, is presented. Using substrate heating to 600°C or more, while using air pressures of 3·10-5 mbar to 0.1 mbar, leads to pronounced crystal structures, from nanowires, to nanocrystallites to closed crystallite films. The crystallinity, chemical structure, atomic composition, optical band gap and internal and external morphology of the WO3-x is studied. Second, the oxygen content of the WO3-x is lowered by the addition of hydrogen during the deposition. Heterogeneous films consisting of layers of various oxygen content result, corresponding to W/WO3-x, WO3/WO3-x configurations. When the air flow is continued upon cooling of the films, additionally WO3-x nanorods are formed on the external surfaces after the deposition. The reduction proceeds more effectively at both low water vapour pressures and at higher temperatures. Third, after synthesising WO3-x nanostructured depositions, atomic hydrogen is used with substrate temperatures of about 730°C to perform reduction. Nanostructured metallic tungsten depositions result consisting of nanofibers, nanocrystallites and closed crystallite films. Furthermore, ultrafine tungsten powder is obtained with particle sizes of 11 nm and very high specific surface areas of 21.5±2 m2·g-1. A novel method for the two-step synthesis of metallic nanostructured tungsten is additionally presented. Fourth, hexagonally ordered arrays of exotic homogeneous hierarchical WO3-x/WO3-x nanocacti are deposited. A novel method for the synthesis of exotic heterogeneous hierarchical WO3-x/WO3-y nanocacti is also presented. Such complex structures are a new foundation of novel applications and enhancements in the field of chromogenics.

  9. A self-assembled supramolecular optical sensor for NiII, CdII, and CrIII.

    PubMed

    Resendiz, Marino J E; Noveron, Juan C; Disteldorf, Hendrick; Fischer, Sonja; Stang, Peter J

    2004-03-04

    A new chromogenic supramolecular sensor for transition metals is reported. It is based on a newly designed phenanthroline-containing molecule that self-assembles via an organometallic "clip" into a supramolecular optical sensor for metals. [reaction: see text

  10. Fluorescent and chromogenic in situ hybridization of CEN17q as a potent useful diagnostic marker for Birt-Hogg-Dubé syndrome-associated chromophobe renal cell carcinomas.

    PubMed

    Kato, Ikuma; Iribe, Yasuhiro; Nagashima, Yoji; Kuroda, Naoto; Tanaka, Reiko; Nakatani, Yukio; Hasumi, Hisashi; Yao, Masahiro; Furuya, Mitsuko

    2016-06-01

    Birt-Hogg-Dubé syndrome (BHD) is a familial disorder associated with a germline mutation of FLCN that is a tumor suppressor gene. Patients with BHD have high risks for developing multiple renal cell carcinomas (RCCs). The frequent histological types are hybrid oncocytic/chromophobe tumors (HOCTs) and chromophobe RCCs. The morphology of HOCTs could alert pathologists to the possibility of BHD. On the other hand, chromophobe RCCs occurring in BHD patients demonstrate positive immunostaining for cytokeratin-7, CD82, and Ksp-cadherin similar to their sporadic counterparts. Highly reliable markers for BHD-associated chromophobe RCCs have not been identified. In the present study, we analyzed the state of chromosome 17 in 18 renal tumors composed of 8 chromophobe RCCs, 7 HOCTs, and 3 papillary RCCs obtained from BHD patients using fluorescent and chromogenic in situ hybridization probes for the centromeric region of chromosome 17 long arm. All chromophobe RCCs and HOCTs were disomic except for 1 chromophobe RCC that showed monosomy. On the other hand, 12 of 14 sporadic chromophobe RCCs were monosomic (P = .0008). The state of chromosomes 2 and 6 were also statistically different (P = .0074 and P = .0007, respectively). Three BHD-associated papillary RCCs demonstrated either trisomy (n = 2) or disomy (n = 1). Three of 5 sporadic papillary RCCs showed trisomy. The results indicate that fluorescent and chromogenic in situ hybridization of the centromeric region of chromosome 17 long arm should be a potent useful marker for chromophobe RCCs in patients who have not been diagnosed with BHD and thereby help to determine whether the cases should be considered for genetic testing. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Betrixaban: Impact on Routine and Specific Coagulation Assays-A Practical Laboratory Guide.

    PubMed

    Siriez, Romain; Evrard, Jonathan; Dogné, Jean-Michel; Pochet, Lionel; Gheldof, Damien; Chatelain, Bernard; Mullier, François; Douxfils, Jonathan

    2018-06-11

     Betrixaban is a novel direct oral factor Xa inhibitor approved by the Food and Drug Administration for prophylaxis of venous thromboembolism in adult patients hospitalized for an acute illness at risk for thromboembolic complications. Assessment of the anti-coagulant effect of betrixaban may be useful in some situations. Also, clinicians need to know how routine coagulation assays are influenced.  The aim of this study is to determine which coagulation assay(s) should be used to assess the impact of betrixaban on haemostasis and provide laboratory guidance for their interpretation.  Betrixaban was spiked at final concentrations ranging from 0 to 250 ng/mL in platelet-poor plasma. Different reagents from several manufacturers were tested and the impact of betrixaban on pro-thrombin time (PT), activated partial thromboplastin time (aPTT), dilute Russel viper venom time (dRVV-T), chromogenic anti-Xa assays, thrombin generation assay (TGA), and a large panel of haemostasis diagnostic tests has been assessed.  A concentration-dependent prolongation of aPTT, PT and dRVV-T is observed. The sensitivity mainly depends on the reagent. Chromogenic anti-Xa assays show high sensitivity depending on the reagent and/or the methodology. These assays applicable for other direct factor Xa inhibitors have to be adapted to obtain a relevant range of measurement. TGA may also be attractive to assess the anti-coagulant activity of betrixaban.  Adapted chromogenic anti-Xa assays are the most appropriate assays to estimate the concentration of betrixaban. Betrixaban significantly affects several haemostasis diagnostic tests and this needs to be taken into consideration when requesting and interpreting such tests. Schattauer GmbH Stuttgart.

  12. Identification of yellow-pigmented bacteria isolated from hospital tap water in Japan and their chlorine resistance.

    PubMed

    Furuhata, Katsunori; Kato, Yuko; Goto, Keiichi; Saitou, Keiko; Sugiyama, Jun-Ichi; Hara, Motonobu; Fukuyama, Masahumi

    2007-06-01

    Twenty-five yellow chromogenic strains isolated from hospital tap water samples collected nationwide were identified by partial 16S rDNA sequencing. In addition, the chlorine resistance of the isolates was experimentally investigated. The results showed that of the strains tested, 12 strains (48.0%) were Sphingomonas ursincola/natatoria, which was most frequently identified, followed by 2 strains (8.0%) of Mycobacterium frederiksbergense and 1 strain (4.0%) each of Sphingomonas adhaesiva, Sphingopyxis witflariensis and Porphyrobacter donghaensis. The other strains were not identified clearly but they belonged to the order of Alphaproteobacteria. On the other hand, the identification results by sequencing and biochemical property testing were not consistent in any of the strains, showing that it was difficult to accurately identify the yellow chromogenic bacteria in tap water based on only their biochemical properties. When the 25 isolates were exposed to 0.1 mg/l residual free chlorine for 1 minute, 22 isolates (88.0%) survived. When the CT (Concentration Time) value killing 99.99% of the bacteria was investigated in 6 of these survivors, M. frederiksbergense (Y-1 strain) was most resistant to chlorine with the CT value of 32 mg x min/l, followed by S. ursincola/natatoria (Y-7 strain) with the CT value of 3.3 mg x min/l. The CT values of Y-5 (Sphingomonas sp.), Y-27 (S. ursincola/natatoria) and Y-21 (Asticacaulis sp.) were within the range of 0.9-0.1 mg x min /l. Of the 6 strains, S. adhaesiva (Y-10) showed the weakest resistance with the CT value of 0.03 mg x min/l. It was clarified that most yellow chromogenic bacteria isolated from hospital tap water were Sphingomonas spp., and these bacteria were experimentally resistant to chlorine.

  13. Comparison of chromogenic Biolog Rainbow agar Shigella/Aeromonas with xylose lysine desoxycholate agar for isolation and detection of Shigella spp. from foods.

    PubMed

    Zhang, Guodong; Lampel, Keith A

    2010-08-01

    Shigella outbreaks are widely reported throughout the world. However, it remains a challenge to isolate Shigella spp. from foods by using conventional microbiological media. The main objective of this study was to determine the effectiveness of a novel chromogenic medium, Rainbow agar Shigella/Aeromonas (Rainbow agar), for the isolation and detection of Shigella spp. in foods. All four Shigella species, S. sonnei, S. flexneri, S. dysenteriae, and S. boydii, were studied. Rainbow agar was compared with tryptic soy agar, xylose lysine desoxycholate agar (XLD), and Salmonella Shigella agar (SSA) for enumeration of Shigella spp. in pure culture. This chromogenic agar and XLD were also used to isolate Shigella spp. in artificially contaminated foods (4.8 log CFU/g of food), including lettuce, parsley, cilantro, spinach, potato salad, and shrimp. The inhibitory effect on Shigella growth by Rainbow agar was between that of XLD and SSA. All vegetables studied showed a moderately high background microflora on XLD and Rainbow agar. With artificially inoculated produce, Rainbow agar recovered about 1 to 2 log CFU more S. sonnei, S. dysenteriae, and S. boydii per g of food than did XLD. For potato salad and shrimp, which had low background microflora on Rainbow agar, Rainbow agar was slightly better in recovering Shigella spp. than XLD was in most cases. However, we found that the addition of streptomycin (6.25 mg/liter) to Rainbow agar could facilitate the isolation of Shigella in vegetables tested. In conclusion, Rainbow agar was a much more effective medium than was XLD for the isolation of Shigella spp. from foods.

  14. Occurrence and characterization of Candida nivariensis from a culture collection of Candida glabrata clinical isolates in Malaysia.

    PubMed

    Tay, Sun Tee; Lotfalikhani, Azadeh; Sabet, Negar Shafiei; Ponnampalavanar, Sasheela; Sulaiman, Sofiah; Na, Shiang Ling; Ng, Kee Peng

    2014-10-01

    Candida nivariensis and C. bracarensis have been recently identified as emerging yeast pathogens which are phenotypically indistinguishable from C. glabrata. However, there is little data on the prevalence and antifungal susceptibilities of these species. This study investigated the occurrence of C. nivariensis and C. bracarensis in a culture collection of 185 C. glabrata isolates at a Malaysian teaching hospital. C. nivariensis was discriminated from C. glabrata using a PCR assay as described by Enache-Angoulvant et al. (J Clin Microbiol 49:3375-9, 2011). The identity of the isolates was confirmed by sequence analysis of the D1D2 domain and internal transcribed spacer region of the yeasts. The isolates were cultured on Chromogenic CHROMagar Candida (®) agar (Difco, USA), and their biochemical and enzymic profiles were determined. Antifungal susceptibilities of the isolates against amphotericin B, fluconazole, voriconazole and caspofungin were determined using E tests. Clotrimazole MICs were determined using a microbroth dilution method. There was a low prevalence (1.1 %) of C. nivariensis in our culture collection of C. glabrata. C. nivariensis was isolated from a blood culture and vaginal swab of two patients. C. nivariensis grew as white colonies on Chromogenic agar and demonstrated few positive reactions using biochemical tests. Enzymatic profiles of the C. nivariensis isolates were similar to that of C. glabrata. The isolates were susceptible to amphotericin B, fluconazole, voriconazole and caspofungin. Clotrimazole resistance is suspected in one isolate. This study reports for the first time the emergence of C. nivariensis in our clinical setting.

  15. Detection of distribution of avian influenza H5N1 virus by immunohistochemistry, chromogenic in situ hybridization and real-time PCR techniques in experimentally infected chickens.

    PubMed

    Chamnanpood, Chanpen; Sanguansermsri, Donruedee; Pongcharoen, Sutatip; Sanguansermsri, Phanchana

    2011-03-01

    Ten specific pathogen free (SPF) chickens were inoculated intranasally with avian influenza virus subtype H5N1. Evaluation revealed distribution of the virus in twelve organs: liver, intestine, bursa, lung, trachea, thymus, heart, pancreas, brain, spleen, kidney, and esophagus. Immunohistochemistry (IHC), chromogenic in situ hybridization (CISH), and real-time polymerase chain reaction (PCR) were developed and compared for detection of the virus from the organs. The distribution of avian influenza H5N1 in chickens varied by animal and detecting technique. The heart, kidneys, intestines, lungs, and pancreas were positive with all three techniques, while the others varied by techique. The three techniques can be used to detect avian influenza effectively, but the pros and cons of each technique need to be determined. The decision of which technique to use depends on the objective of the examination, budget, type and quality of samples, laboratory facilities and technician skills.

  16. Evaluation of Five Chromogenic Agar Media and the Rosco Rapid Carb Screen Kit for Detection and Confirmation of Carbapenemase Production in Gram-Negative Bacilli

    PubMed Central

    Gilmour, Matthew W.; DeGagne, Pat; Nichol, Kim; Karlowsky, James A.

    2014-01-01

    An efficient workflow to screen for and confirm the presence of carbapenemase-producing Gram-negative bacilli was developed by evaluating five chromogenic screening agar media and two confirmatory assays, the Rapid Carb screen test (Rosco Diagnostica A/S, Taastrup, Denmark) and the modified Hodge test. A panel of 150 isolates was used, including 49 carbapenemase-producing isolates representing a variety of β-lactamase enzyme classes. An evaluation of analytical performance, assay cost, and turnaround time indicated that the preferred workflow (screening test followed by confirmatory testing) was the chromID Carba agar medium (bioMérieux, Marcy l'Étoile, France), followed by the Rapid Carb screen test, yielding a combined sensitivity of 89.8% and a specificity of 100%. As an optional component of the workflow, a determination of carbapenemase gene class via molecular means could be performed subsequent to confirmatory testing. PMID:25355764

  17. A chromogenic and fluorogenic rhodol-based chemosensor for hydrazine detection and its application in live cell bioimaging

    NASA Astrophysics Data System (ADS)

    Tiensomjitr, Khomsan; Noorat, Rattha; Chomngam, Sinchai; Wechakorn, Kanokorn; Prabpai, Samran; Kanjanasirirat, Phongthon; Pewkliang, Yongyut; Borwornpinyo, Suparerk; Kongsaeree, Palangpon

    2018-04-01

    A rhodol-based fluorescent probe has been developed as a selective hydrazine chemosensor using levulinate as a recognition site. The rhodol levulinate probe (RL) demonstrated high selectivity and sensitivity toward hydrazine among other molecules. The chromogenic response of RL solution to hydrazine from colorless to pink could be readily observed by the naked eye, while strong fluorescence emission could be monitored upon excitation at 525 nm. The detection process occurred via a ring-opening process of the spirolactone initiated by hydrazinolysis, triggering the fluorescence emission with a 53-fold enhancement. The probe rapidly reacted with hydrazine in aqueous medium with the detection limit of 26 nM (0.83 ppb), lower than the threshold limit value (TLV) of 10 ppb suggested by the U.S. Environmental Protection Agency. Furthermore, RL-impregnated paper strips could detect hydrazine vapor. For biological applicability of RL, its membrane-permeable property led to bioimaging of hydrazine in live HepG2 cells by confocal fluorescence microscopy.

  18. Mesotrypsin Signature Mutation in a Chymotrypsin C (CTRC) Variant Associated with Chronic Pancreatitis.

    PubMed

    Szabó, András; Ludwig, Maren; Hegyi, Eszter; Szépeová, Renata; Witt, Heiko; Sahin-Tóth, Miklós

    2015-07-10

    Human chymotrypsin C (CTRC) protects against pancreatitis by degrading trypsinogen and thereby curtailing harmful intra-pancreatic trypsinogen activation. Loss-of-function mutations in CTRC increase the risk for chronic pancreatitis. Here we describe functional analysis of eight previously uncharacterized natural CTRC variants tested for potential defects in secretion, proteolytic stability, and catalytic activity. We found that all variants were secreted from transfected cells normally, and none suffered proteolytic degradation by trypsin. Five variants had normal enzymatic activity, whereas variant p.R29Q was catalytically inactive due to loss of activation by trypsin and variant p.S239C exhibited impaired activity possibly caused by disulfide mispairing. Surprisingly, variant p.G214R had increased activity on a small chromogenic peptide substrate but was markedly defective in cleaving bovine β-casein or the natural CTRC substrates human cationic trypsinogen and procarboxypeptidase A1. Mutation p.G214R is analogous to the evolutionary mutation in human mesotrypsin, which rendered this trypsin isoform resistant to proteinaceous inhibitors and conferred its ability to cleave these inhibitors. Similarly to the mesotrypsin phenotype, CTRC variant p.G214R was inhibited poorly by eglin C, ecotin, or a CTRC-specific variant of SGPI-2, and it readily cleaved the reactive-site peptide bonds in eglin C and ecotin. We conclude that CTRC variants p.R29Q, p.G214R, and p.S239C are risk factors for chronic pancreatitis. Furthermore, the mesotrypsin-like CTRC variant highlights how the same natural mutation in homologous pancreatic serine proteases can evolve a new physiological role or lead to pathology, determined by the biological context of protease function. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  19. Structural and Functional Characterization of Cleavage and Inactivation of Human Serine Protease Inhibitors by the Bacterial SPATE Protease EspPα from Enterohemorrhagic E. coli

    PubMed Central

    Weiss, André; Joerss, Hanna; Brockmeyer, Jens

    2014-01-01

    EspPα and EspI are serine protease autotransporters found in enterohemorrhagic Escherichia coli. They both belong to the SPATE autotransporter family and are believed to contribute to pathogenicity via proteolytic cleavage and inactivation of different key host proteins during infection. Here, we describe the specific cleavage and functional inactivation of serine protease inhibitors (serpins) by EspPα and compare this activity with the related SPATE EspI. Serpins are structurally related proteins that regulate vital protease cascades, such as blood coagulation and inflammatory host response. For the rapid determination of serpin cleavage sites, we applied direct MALDI-TOF-MS or ESI-FTMS analysis of coincubations of serpins and SPATE proteases and confirmed observed cleavage positions using in-gel-digest of SDS-PAGE-separated degradation products. Activities of both serpin and SPATE protease were assessed in a newly developed photometrical assay using chromogenic peptide substrates. EspPα cleaved the serpins α1-protease inhibitor (α1-PI), α1-antichymotrypsin, angiotensinogen, and α2-antiplasmin. Serpin cleavage led to loss of inhibitory function as demonstrated for α1-PI while EspPα activity was not affected. Notably, EspPα showed pronounced specificity and cleaved procoagulatory serpins such as α2-antiplasmin while the anticoagulatory antithrombin III was not affected. Together with recently published research, this underlines the interference of EspPα with hemostasis or inflammatory responses during infection, while the observed interaction of EspI with serpins is likely to be not physiologically relevant. EspPα-mediated serpin cleavage occurred always in flexible loops, indicating that this structural motif might be required for substrate recognition. PMID:25347319

  20. Fibrinogenolytic and anticoagulant activities in the tissue covering the stingers of marine stingrays Dasyatis sephen and Aetobatis narinari.

    PubMed

    Kumar, Kalainesan Rajesh; Vennila, Rathinam; Kanchana, Shankar; Arumugam, Muthuvel; Balasubramaniam, Thangavel

    2011-05-01

    Stingray envenomation is one of the major problems in the marine and freshwater ecosystem. Accidents in human cause immediate, local and intense pain, erythema, edema, hemorrhage, tissue necrosis and secondary bacterial infection are also common. To determine the effect of two marine stingray species Dasyatis sephen and Aetobatis narinari venom extract on coagulation, fibrin(ogen)olytic, proteolytic activities. Plasma coagulation, Thrombin catalyzed fibrinocoagulation, Fibrin plate assay, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), substrate SDS-PAGE and thrombin like activity by using chromogenic substrate were used to determine the effect of venom on plasma coagulation, its fibrin(ogen)olytic and proteolytic activity. The results show the presence of fibrin(ogen)olytic, anticoagulant and gelatinolytic activity in both stingray venom extracts. D. sephen venom delays coagulation of citrated plasma more significantly than A. narinari upon using increasing concentration of the venom. The same results were obtained in the fibrinocoagulation assays. SDS-PAGE analysis of fibrinogen and fibrin after incubation with D. sephen and A. narinari venom show fibrin(ogen)olytic activity. Through SDS-PAGE analysis it is confirmed that the delaying in coagulation process by stingray venom is due to its fibrin(ogen)olytic activity and fibrinolytic activity also confirmed through fibrin plate assay. Zymogram analysis shows the presence of array of gelatinolytic and fibrinogenolytic enzymes above 43-276 kDa in the D. sephen and A. narinari venom respectively. Protease inhibitor studies show the serine and metallo proteases are responsible for these activities. From the results, fibrinogenolytic, proteolytic activity of the stingray venom is confirmed, but it has no thrombin like activity and these activities may aid in hemorrhages, tissue necrosis and secondary bacterial infections at the site of envenomation.

  1. High-performance peroxidase mimics for rapid colorimetric detection of H2O2 and glucose derived from perylene diimides functionalized Co3O4 nanoparticles.

    PubMed

    Ding, Yanan; Chen, Miaomiao; Wu, Kaili; Chen, Mingxing; Sun, Lifang; Liu, Zhenxue; Shi, Zhiqiang; Liu, Qingyun

    2017-11-01

    N,N'-di-caboxy methyl perylene diimides (PDI), as one of the most promising functional materials in optional chemosensing, was first used to combine with Co 3 O 4 nanoparticles through a facile two-step hydrothermal method and obtain the PDI functionalized Co 3 O 4 nanocomposites (PDI-Co 3 O 4 NCs). PDI-Co 3 O 4 NCs were characterized by a series of technical analysis including transmission electron microscope (TEM), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FT-IR), respectively. The experimental results indicated that the as-prepared PDI-Co 3 O 4 NCs possessed the higher peroxidase-like activity than that of Co 3 O 4 nanoparticles without PDI, and could rapidly catalyze oxidation reaction of the chromogenic substrate TMB in the presence of H 2 O 2 to a blue product (oxTMB) observed by the naked eye. The improved catalytic activity of PDI-Co 3 O 4 NCs for colorimetric reactions could be attributed to the synergistic effects of PDI and Co 3 O 4 nanoparticles. On the basis of these experimental results, a convenient colorimetric system based on PDI-Co 3 O 4 as enzyme mimic that is highly sensitive and selective was developed for glucose detection. Meanwhile, the electron transfer between H 2 O 2 and TMB was responsible for the oxidation of TMB. The present work demonstrates a general strategy for the design of organic molecules functionalized oxide for different applications, such as nanocatalysts, biosensors and nanomedicine. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Thrombin-inhibiting perfluorocarbon nanoparticles provide a novel strategy for treatment and magnetic resonance imaging of acute thrombosis

    PubMed Central

    Myerson, J.; He, L.; Lanza, G.; Tollefsen, D.; Wickline, S.

    2013-01-01

    Background As a regulator of the penultimate step in the coagulation cascade, thrombin represents a principal target of direct and specific anticoagulants. Objective A potent thrombin inhibitor complexed with a colloidal nanoparticle was devised as a first-in-class anticoagulant with prolonged and highly localized therapeutic impact conferred by its multivalent thrombin-absorbing particle surface. Methods PPACK (Phe(D)-Pro-Arg-Chloromethylketone) was secured covalently to the surface of perfluorocarbon-core nanoparticle structures. PPACK and PPACK nanoparticle inhibition of thrombin were assessed in vitro via thrombin activity against a chromogenic substrate. In vivo antithrombotic activity of PPACK, heparin, non-functionalized nanoparticles, and PPACK nanoparticles was assessed through IV administration prior to acute photochemical injury of the common carotid artery. Perfluorocarbon particle retention in extracted carotid arteries from injured mice was assessed via 19F magnetic resonance spectroscopy (MRS) and imaging (MRI) at 11.7 T. APTT measurements determined the systemic effects of the PPACK nanoparticles at various times after injection. Results Optical assay verified that PPACK nanoparticles exceeded PPACK’s intrinsic activity against thrombin. Application of the an in vivo acute arterial thrombosis model demonstrated that PPACK nanoparticles outperformed both heparin (p=.001) and uncomplexed PPACK (p=.0006) in inhibiting thrombosis. 19F MRS confirmed that PPACK nanoparticles specifically bound to sites of acute thrombotic injury. APTT normalized within twenty minutes of PPACK nanoparticles injection. Conclusions PPACK nanoparticles present thrombin-inhibiting surfaces at sites of acutely forming thrombi that continue to manifest local clot inhibition even as systemic effects rapidly diminish and thus represent a new platform for localized control of acute thrombosis. PMID:21605330

  3. Identification of non-Listeria spp. bacterial isolates yielding a β-D-glucosidase-positive phenotype on Agar Listeria according to Ottaviani and Agosti (ALOA).

    PubMed

    Angelidis, Apostolos S; Kalamaki, Mary S; Georgiadou, Sofia S

    2015-01-16

    Agar Listeria according to Ottaviani and Agosti (ALOA) is the mandatory medium used for the detection and enumeration of Listeria monocytogenes in foods according to the official International Organization for Standardization (ISO) methods. On ALOA, Listeria spp. appear as bluish-green colonies due to the production of β-D-glucosidase, an enzyme that cleaves 5-bromo-4-chloro-3-indolyl-β-D-glucopyranoside, a chromogenic substrate included in the formulation of the medium. The present work reports on bacterial isolates (n=64) from ready-to-eat soft cheeses, which are able to grow on ALOA, forming bluish-green colonies and therefore phenotypically resemble Listeria spp. All isolates were also capable of growing on the selective media PALCAM and RAPID L'mono. The isolates were characterised with biochemical tests including those specified in the ISO standards for the confirmation of Listeria spp. and identified via partial sequencing of their 16S rRNA gene. According to sequencing results the isolates represented 12 different bacterial species or species-groups belonging to seven different genera: Bacillus spp. (B. circulans, B. clausii, B. licheniformis and B. oleronius), Cellulosimicrobium spp. (C. funkei), Enterococcus spp. (E. faecalis, E. faecium/durans), Kocuria spp. (K. kristinae), Marinilactibacillus spp. (M. psychrotolerans), Rothia spp. (R. terrae) and Staphylococcus spp. (S. sciuri and S. saprophyticus subsp. saprophyticus/xylosus). Cellulosimicrobium spp. have never been previously isolated from foods. These results significantly extend the list of bacteria previously known as capable of growing on ALOA as bluish-green colonies and suggest that there may be room for further improvement in the medium's inhibitory properties towards non-Listeria spp., Gram-positive bacteria present in foods. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Efficacy and safety of BAY 81-8973, a full-length recombinant factor VIII: results from the LEOPOLD I trial.

    PubMed

    Saxena, K; Lalezari, S; Oldenburg, J; Tseneklidou-Stoeter, D; Beckmann, H; Yoon, M; Maas Enriquez, M

    2016-09-01

    BAY 81-8973 (Kovaltry(®) ) is a full-length, unmodified recombinant human factor VIII (FVIII) with the same amino acid sequence as sucrose-formulated recombinant FVIII and is produced using additional advanced manufacturing technologies. To demonstrate efficacy and safety of BAY 81-8973 for treatment of bleeds and as prophylaxis based on two different potency assignments. In LEOPOLD I (ClinicalTrials.gov identifier, NCT01029340), males aged 12-65 years with severe haemophilia A and ≥150 exposure days received BAY 81-8973 20-50 IU kg(-1) two or three times per week for 12 months. Potency was based on chromogenic substrate assay per European Pharmacopoeia and label adjusted to mimic one-stage assay potency. Patients were randomized for potency sequence and crossed over potency groups after 6 months, followed by an optional 12-month extension. Primary efficacy endpoint was annualized bleeding rate (ABR). Patients also received BAY 81-8973 during major surgeries. Sixty-two patients received BAY 81-8973 prophylaxis and were included in the analysis. Median ABR was 1.0 (quartile 1, 0; quartile 3, 5.1) without clinically relevant differences between potency periods. Median ABR was similar for twice-weekly vs. three times-weekly dosing (1.0 vs. 2.0). Haemostasis was maintained during 12 major surgeries. Treatment-related adverse event (AE) incidence was ≤7% overall; no patient developed inhibitors. One patient with risk factors for cardiovascular disease developed a myocardial infarction. BAY 81-8973 was efficacious in preventing and treating bleeding episodes, irrespective of the potency assignment method, with few treatment-related AEs. Caution should be used when treating older patients with cardiovascular risk factors. © 2016 Bayer. Haemophilia Published by John Wiley & Sons Ltd.

  5. Pyrocatechol violet in pharmaceutical analysis. Part I. A spectrophotometric method for the determination of some beta-lactam antibiotics in pure and in pharmaceutical dosage forms.

    PubMed

    Amin, A S

    2001-03-01

    A fairly sensitive, simple and rapid spectrophotometric method for the determination of some beta-lactam antibiotics, namely ampicillin (Amp), amoxycillin (Amox), 6-aminopenicillanic acid (6APA), cloxacillin (Clox), dicloxacillin (Diclox) and flucloxacillin sodium (Fluclox) in bulk samples and in pharmaceutical dosage forms is described. The proposed method involves the use of pyrocatechol violet as a chromogenic reagent. These drugs produce a reddish brown coloured ion pair with absorption maximum at 604, 641, 645, 604, 649 and 641 nm for Amp, Amox, 6APA, Clox, Diclox and Flucolx, respectively. The colours produced obey Beer's law and are suitable for the quantitative determination of the named compounds. The optimization of different experimental conditions is described. The molar ratio of the ion pairs was established and a proposal for the reaction pathway is given. The procedure described was applied successfully to determine the examined drugs in dosage forms and the results obtained were comparable to those obtained with the official methods.

  6. Development and validation of spectrophotometric methods for estimating amisulpride in pharmaceutical preparations.

    PubMed

    Sharma, Sangita; Neog, Madhurjya; Prajapati, Vipul; Patel, Hiren; Dabhi, Dipti

    2010-01-01

    Five simple, sensitive, accurate and rapid visible spectrophotometric methods (A, B, C, D and E) have been developed for estimating Amisulpride in pharmaceutical preparations. These are based on the diazotization of Amisulpride with sodium nitrite and hydrochloric acid, followed by coupling with N-(1-naphthyl)ethylenediamine dihydrochloride (Method A), diphenylamine (Method B), beta-naphthol in an alkaline medium (Method C), resorcinol in an alkaline medium (Method D) and chromotropic acid in an alkaline medium (Method E) to form a colored chromogen. The absorption maxima, lambda(max), are at 523 nm for Method A, 382 and 490 nm for Method B, 527 nm for Method C, 521 nm for Method D and 486 nm for Method E. Beer's law was obeyed in the concentration range of 2.5-12.5 microg mL(-1) in Method A, 5-25 and 10-50 microg mL(-1) in Method B, 4-20 microg mL(-1) in Method C, 2.5-12.5 microg mL(-1) in Method D and 5-15 microg mL(-1) in Method E. The results obtained for the proposed methods are in good agreement with labeled amounts, when marketed pharmaceutical preparations were analyzed.

  7. Simple and sensitive method for the quantification of total bilirubin in human serum using 3-methyl-2-benzothiazolinone hydrazone hydrochloride as a chromogenic probe

    NASA Astrophysics Data System (ADS)

    Nagaraja, Padmarajaiah; Avinash, Krishnegowda; Shivakumar, Anantharaman; Dinesh, Rangappa; Shrestha, Ashwinee Kumar

    2010-11-01

    We here describe a new spectrophotometric method for measuring total bilirubin in serum. The method is based on the cleavage of bilirubin giving formaldehyde which further reacts with diazotized 3-methyl-2-benzothiazolinone hydrazone hydrochloride giving blue colored solution with maximum absorbance at 630 nm. Sensitivity of the developed method was compared with Jendrassik-Grof assay procedure and its applicability has been tested with human serum samples. Good correlation was attained between both methods giving slope of 0.994, intercept 0.015, and R2 = 0.997. Beers law obeyed in the range of 0.068-17.2 μM with good linearity, absorbance y = 0.044 Cbil + 0.003. Relative standard deviation was 0.006872, within day precision ranged 0.3-1.2% and day-to-day precision ranged 1-6%. Recovery of the method varied from 97 to 102%. The proposed method has higher sensitivity with less interference. The obtained product was extracted and was spectrally characterized for structural confirmation with FT-IR, 1H NMR.

  8. Antithrombin activity of medicinal plants of the Azores.

    PubMed

    de Medeiros, J M; Macedo, M; Contancia, J P; Nguyen, C; Cunningham, G; Miles, D H

    2000-09-01

    A chromogenic bioassay was utilized to determine the antithrombin activity of methylene chloride and methanol extracts prepared from 50 plants of Azores. Extracts of the six plants Hedychium gardneranum, Tropaeolum majus, Gunnera tinctoria, Hedera helix, Festuca jubata and Laurus azorica demonstrated activity of 78% or higher in this bioassay system.

  9. An efficient, cost effective, sensing behaviour liquid-liquid extraction and spectrophotometric determination of copper(II) incorporated with 4-(4‧-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole: Analysis of food samples, leafy vegetables, fertilizers and environmental samples

    NASA Astrophysics Data System (ADS)

    Barache, Umesh B.; Shaikh, Abdul B.; Lokhande, Tukaram N.; Kamble, Ganesh S.; Anuse, Mansing A.; Gaikwad, Shashikant H.

    2018-01-01

    The aim of the present work is to develop an efficient, simple and selective moreover cost-effective method for the extractive spectrophotometric determination of copper(II) by using the Schiff base 4-(4‧-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole [CBIMMT]. This chromogenic reagent forms a yellow coloured complex with copper(II) in acetate buffer at pH 4.2. The copper(II) complex with ligand is instantly extracted into chloroform and shows a maximum absorbance at 414 nm which remains stable for > 48 h. The composition of extracted complex is found to be 1:2 [copper(II): reagent] which was ascertained using Job's method of continuous variation, mole ratio method and slope ratio method. Under optimal conditions, the copper(II) complex in chloroform adheres to Beer's law up to 17.5 μg mL- 1 of copper(II). The optimum concentration range obtained from Ringbom's plot is from 5 μg mL- 1 to 17.5 μg mL- 1. The molar absorptivity, Sandell's sensitivity and enrichment factor of the extracted copper(II) chelate are 0.33813 × 104 L mol- 1 cm- 1, 0.01996 μg cm- 2 and 2.49 respectively. In the extraction of copper(II), several affecting factors including the solution pH, ligand concentration, equilibrium time, effect of foreign ions are optimized. The interfering effects of various cations and anions were also studied and use of masking agents enhances the selectivity of the method. The chromogenic sulphur containing reagent, 4-(4‧-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole has been synthesized in a single step with high purity and yield. The synthesized reagent has been successfully applied first time for determination of copper(II). The reagent forms stable chelate with copper(II) in buffer medium instantly and quantitatively extracted in chloroform within a minute. The method is successfully applied for the determination of copper(II) in various synthetic mixtures, complexes, fertilizers, environmental samples such as food samples, leafy vegetables, and water samples. The results are compared with those obtained with a reference procedure. Good agreement was attained. All the obtained results are indicative of a convenient, fast method for the extraction and quantification of micro levels of copper(II) from various environmental matrices without use of sophisticated instrumentation and procedure. The method showed a relative standard deviation of 0.42%.

  10. An interlaboratory study on efficient detection of Shiga toxin-producing Escherichia coli O26, O103, O111, O121, O145, and O157 in food using real-time PCR assay and chromogenic agar.

    PubMed

    Hara-Kudo, Yukiko; Konishi, Noriko; Ohtsuka, Kayoko; Iwabuchi, Kaori; Kikuchi, Rie; Isobe, Junko; Yamazaki, Takumiko; Suzuki, Fumie; Nagai, Yuhki; Yamada, Hiroko; Tanouchi, Atsuko; Mori, Tetsuya; Nakagawa, Hiroshi; Ueda, Yasufumi; Terajima, Jun

    2016-08-02

    To establish an efficient detection method for Shiga toxin (Stx)-producing Escherichia coli (STEC) O26, O103, O111, O121, O145, and O157 in food, an interlaboratory study using all the serogroups of detection targets was firstly conducted. We employed a series of tests including enrichment, real-time PCR assays, and concentration by immunomagnetic separation, followed by plating onto selective agar media (IMS-plating methods). This study was particularly focused on the efficiencies of real-time PCR assays in detecting stx and O-antigen genes of the six serogroups and of IMS-plating methods onto selective agar media including chromogenic agar. Ground beef and radish sprouts samples were inoculated with the six STEC serogroups either at 4-6CFU/25g (low levels) or at 22-29CFU/25g (high levels). The sensitivity of stx detection in ground beef at both levels of inoculation with all six STEC serogroups was 100%. The sensitivity of stx detection was also 100% in radish sprouts at high levels of inoculation with all six STEC serogroups, and 66.7%-91.7% at low levels of inoculation. The sensitivity of detection of O-antigen genes was 100% in both ground beef and radish sprouts at high inoculation levels, while at low inoculation levels, it was 95.8%-100% in ground beef and 66.7%-91.7% in radish sprouts. The sensitivity of detection with IMS-plating was either the same or lower than those of the real-time PCR assays targeting stx and O-antigen genes. The relationship between the results of IMS-plating methods and Ct values of real-time PCR assays were firstly analyzed in detail. Ct values in most samples that tested negative in the IMS-plating method were higher than the maximum Ct values in samples that tested positive in the IMS-plating method. This study indicates that all six STEC serogroups in food contaminated with more than 29CFU/25g were detected by real-time PCR assays targeting stx and O-antigen genes and IMS-plating onto selective agar media. Therefore, screening of stx and O-antigen genes followed by isolation of STECs by IMS-plating methods may be an efficient method to detect the six STEC serogroups. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. An efficient, cost effective, sensing behaviour liquid-liquid extraction and spectrophotometric determination of copper(II) incorporated with 4-(4'-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole: Analysis of food samples, leafy vegetables, fertilizers and environmental samples.

    PubMed

    Barache, Umesh B; Shaikh, Abdul B; Lokhande, Tukaram N; Kamble, Ganesh S; Anuse, Mansing A; Gaikwad, Shashikant H

    2018-01-15

    The aim of the present work is to develop an efficient, simple and selective moreover cost-effective method for the extractive spectrophotometric determination of copper(II) by using the Schiff base 4-(4'-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole [CBIMMT]. This chromogenic reagent forms a yellow coloured complex with copper(II) in acetate buffer at pH4.2. The copper(II) complex with ligand is instantly extracted into chloroform and shows a maximum absorbance at 414nm which remains stable for >48h. The composition of extracted complex is found to be 1:2 [copper(II): reagent] which was ascertained using Job's method of continuous variation, mole ratio method and slope ratio method. Under optimal conditions, the copper(II) complex in chloroform adheres to Beer's law up to 17.5μgmL -1 of copper(II). The optimum concentration range obtained from Ringbom's plot is from 5μgmL -1 to 17.5μgmL -1 . The molar absorptivity, Sandell's sensitivity and enrichment factor of the extracted copper(II) chelate are 0.33813×10 4 Lmol -1 cm -1 , 0.01996μgcm -2 and 2.49 respectively. In the extraction of copper(II), several affecting factors including the solution pH, ligand concentration, equilibrium time, effect of foreign ions are optimized. The interfering effects of various cations and anions were also studied and use of masking agents enhances the selectivity of the method. The chromogenic sulphur containing reagent, 4-(4'-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole has been synthesized in a single step with high purity and yield. The synthesized reagent has been successfully applied first time for determination of copper(II). The reagent forms stable chelate with copper(II) in buffer medium instantly and quantitatively extracted in chloroform within a minute. The method is successfully applied for the determination of copper(II) in various synthetic mixtures, complexes, fertilizers, environmental samples such as food samples, leafy vegetables, and water samples. The results are compared with those obtained with a reference procedure. Good agreement was attained. All the obtained results are indicative of a convenient, fast method for the extraction and quantification of micro levels of copper(II) from various environmental matrices without use of sophisticated instrumentation and procedure. The method showed a relative standard deviation of 0.42%. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Characterization of a potent platelet aggregation inducer from Cerastes cerastes (Egyptian sand viper) venom.

    PubMed

    Basheer, A R; el-Asmar, M F; Soslau, G

    1995-07-03

    A potent, proteinaceous inducer of platelet aggregation designated as IVa, has been purified to homogeneity from Cerastes cerastes venom by molecular sieve and ion exchange chromatography. It is composed of 2 subunits with total M(r) of 62,000 as shown by native gel chromatography and chemical cross-linking with disuccinimidyl suberate. It is not clear at the present time whether both subunits are identical gene products, however, both have identical N-terminal sequences for the first 15 amino acids. The protein has a pI above 9.6. IVa (0.1 micrograms/ml) could aggregate platelets up to 80% and was inhibited by p-APMSF, leupeptin, iodoacetamide, protein kinase C inhibitor, phosphatase inhibitor, ATP and PGE1, while it was insensitive to acetylsalicylic acid, ADP scavenger system, protein kinase A inhibitor and hirudin. Protein IVa is a serine proteinase with thrombin-like activity as it hydrolysed thrombin chromogenic substrate CBS 34.47, its aggregatory activity was partially inhibited by monoclonal antibodies against GPIb and the thrombin receptor, as was the thrombin, and its ability to induce intracellular Ca2+ release was blocked by pretreating platelets with thrombin. Unlike thrombin, the IVa protein showed very weak coagulant activity as indicated by plasma recalcification time and fibrinogen clotting time although it could hydrolyse fibrinogen alpha-chains.

  13. A cyclohexanecarboxamide derivative with inhibitory effects on Schistosoma mansoni cercarial serine protease and penetration of mice skin by the parasite.

    PubMed

    Bahgat, Mahmoud; Aboul-Enein, Mohamed N; El Azzouny, Aida A; Maghraby, Amany; Ruppel, Andreas; Soliman, Wael M

    2009-01-01

    A cyclohexanecarboxamide derivative, N-phenyl-N-[1-(piperidine-1-carbonyl)cyclohexyl] benzamide (MNRC-5), was evaluated for its inhibitory effects on Schistosoma mansoni cercarial serine protease activity and cercarial penetration. MNRC-5 exerted an inhibitory effect on S. mansoni cercarial serine protease at serial concentrations of the specific chromogenic substrate Boc-Val-Leu-Gly-Arg-PNA for such enzyme family and the inhibitory coefficient (Ki) value was deduced. Moreover, topical treatment of mice tails with the most potent inhibitory concentration of MNRC-5 formulated in jojoba oil successfully blocked cercarial penetration as demonstrated by a significant reduction (75%; p < 0.05) in the recovered S. mansoni worms from treated mice in comparison to control ones whose tails were painted with jojoba oil base containing no MNRC-5. In addition, the IgM and IgG reactivities to crude S. mansoni cercarial, worm and egg antigens were generally lower in sera from treated infected mice than untreated infected mice. In conclusion, we report on a new serine protease inhibitor capable for blocking penetration of host skin by S. mansoni cercariae as measured by lowering worm burden and decrease in the levels of both IgM and IgG towards different bilharzial antigens upon topical treatment.

  14. Cloned cytolytic T-effector cells and their malignant variants produce an extracellular matrix degrading trypsin-like serine proteinase.

    PubMed Central

    Simon, M M; Simon, H G; Fruth, U; Epplen, J; Müller-Hermelink, H K; Kramer, M D

    1987-01-01

    This report describes the distribution of a trypsin-like proteinase in defined homogeneous cytolytic T-cell lines (CTLL) and their in vitro and in vivo derived malignant T-lymphoma variants. By means of chromogenic peptide substrates, we found the enzyme to attack preferentially at the carboxy terminus of arginine, in particular when non-polar amino acids were present in the amino terminal neighbouring position. The enzyme was identified by means of various inhibitors as a serine type proteinase having a pH optimum around 8 X 5. Affinity chromatography in connection with molecular sieving resulted in a 200-fold purification and indicated a molecular weight (MW) of about 50,000 for the proteinase. The enzyme was found to be highly expressed in antigen-specific CTLL as well as in their tumorigenic variants. Both intact lymphocytes of all CTLL tested and Triton X-100 lysates or enriched proteinase preparations thereof were able to degrade a high molecular weight protein (casein) and to release high molecular weight split products from the sulphated proteoglycans in subendothelial extracellular matrix. The results are discussed with respect to the invasiveness of normal and malignant T lymphocytes and the proteinase is suggested to be crucially involved in the process of cellular migration in vivo. Images Figure 1 PMID:3546101

  15. Salivary Concentrations of Interleukin (IL)-1β, IL-17A, and IL-23 Vary in Relation to Periodontal Status.

    PubMed

    Liukkonen, Joonas; Gürsoy, Ulvi K; Pussinen, Pirkko J; Suominen, Anna L; Könönen, Eija

    2016-12-01

    Interleukin (IL)-23-induced T helper (Th) 17 pathway is involved in the pathogenesis of periodontal disease. This study's aim is to determine levels of IL-1β, IL-17A, IL-23, and lipopolysaccharide (LPS) in saliva, and to examine whether their salivary concentrations are associated with periodontal health status. Saliva samples originated from 220 participants; 76 had generalized periodontitis (GP) and 65 had localized periodontitis (LP), whereas 79 without periodontitis were used as controls. Cytokine analyses were performed by a flow cytometry-based technique and LPS analyses from pellet by commercially optimized assay coupled with chromogenic substrate. Salivary concentrations of IL-17A and IL-23 were elevated significantly in patients with LP compared with controls and patients with GP. Salivary IL-1β concentrations were significantly higher in patients with GP than in patients with LP, whereas no difference was found between LP and control groups. Significant correlation was found between concentrations of IL-17A and IL-23 or IL-1β. LPS concentrations did not have significant associations with any of the tested ILs. Elevated salivary IL-1β concentrations are related to GP, whereas distinct elevation and reduction profiles of IL-17A and IL-23 are detected in saliva of patients with LP and GP.

  16. The role of amoebocytes in endotoxin-mediated coagulation in the innate immunity of Achatina fulica snails.

    PubMed

    Biswas, C; Mandal, C

    1999-02-01

    Achatina amoebocyte lysate (AAL) derived from amoebocytes of Achatina fulica was activated by Gram-negative bacterial endotoxins in a time-dependent manner resulting in gel formation/coagulation. The activation and maximum proliferation of amoebocytes was observed 40 min after intramuscular injection (20 microg/snail) of endotoxin. Endotoxin-mediated proteolytic activity of AAL towards a serine-protease-specific chromogenic substrate was maximum at pH 8.0, 37 degrees C and within 15 min in a divalent-cation-dependent manner. The AAL activity induced by the endotoxin was directly dependent on the endotoxin concentration, showed a high specificity and saturated at higher endotoxin concentrations. An endotoxin-sensitive factor (ESF) was purified from AAL to apparent homogeneity by single-step affinity chromatography on a heparin-Sepharose 4B column. Native ESF of molecular weight 140 000 was composed of two identical subunits of molecular weight 70 000 attached through non-covalent association. A strong binding to endotoxin (Escherichia coli 055:B5) was exhibited by ESF with a 40-fold higher biological activity than AAL. The ESF was shown to have a unique Phe-Ile active site with regard to its alternate activation by alpha-chymotrypsin instead of endotoxin. The ESF was characterized as a serine protease type as evidenced by potent inhibition with specific inhibitors.

  17. Application of a paper based device containing a new culture medium to detect Vibrio cholerae in water samples collected in Haiti.

    PubMed

    Briquaire, Romain; Colwell, Rita R; Boncy, Jacques; Rossignol, Emmanuel; Dardy, Aline; Pandini, Isabelle; Villeval, François; Machuron, Jean-Louis; Huq, Anwar; Rashed, Shah; Vandevelde, Thierry; Rozand, Christine

    2017-02-01

    Cholera is now considered to be endemic in Haiti, often with increased incidence during rainy seasons. The challenge of cholera surveillance is exacerbated by the cost of sample collection and laboratory analysis. A diagnostic tool is needed that is low cost, easy-to-use, and able to detect and quantify Vibrio cholerae accurately in water samples within 18-24h, and perform reliably in remote settings lacking laboratory infrastructure and skilled staff. The two main objectives of this study were to develop and evaluate a new culture medium embedded in a new diagnostic tool (PAD for paper based analytical device) for detecting Vibrio cholerae from water samples collected in Haiti. The intent is to provide guidance for corrective action, such as chlorination, for water positive for V. cholerae epidemic strains. For detecting Vibrio cholerae, a new chromogenic medium was designed and evaluated as an alternative to thiosulfate citrate bile salts sucrose (TCBS) agar for testing raw water samples. Sensitivity and specificity of the medium were assessed using both raw and spiked water samples. The Vibrio cholerae chromogenic medium was proved to be highly selective against most of the cultivable bacteria in the water samples, without loss of sensitivity in detection of V. cholerae. Thus, reliability of this new culture medium for detection of V. cholerae in the presence of other Vibrio species in water samples offers a significant advantage. A new paper based device containing the new chromogenic medium previously evaluated was compared with reference methods for detecting V. cholerae from spiked water sample. The microbiological PAD specifications were evaluated in Haiti. More precisely, a total of 185 water samples were collected at five sites in Haiti, June 2014 and again in June 2015. With this new tool, three V. cholerae O1 and 17 V. cholerae non-O1/O139 strains were isolated. The presence of virulence-associated and regulatory genes, including ctxA, zot, ace, and toxR, was confirmed using multiplex PCR. The three V. cholerae O1 isolates were positive for three of the four virulence-associated and regulatory genes. Twelve of the V. cholerae non-O1/O139 isolates were found to carry toxR, but none were ctxA+, zot+, or ace+. However, six of the V. cholerae non-O1/O139 isolates were resistant to penicillin, ampicillin, trimethoprim/sulfamethoxazole, nalidixic acid, and ciprofloxacin. The paper based analytical device (PAD) provides advantages in that standard culture methods employing agar plates are not required. Also, intermediary isolation steps were not required, including transfer to selective growth media, hence these steps being omitted reduced time to results. Furthermore, experienced technical skills also were not required. Thus, PAD is well suited for resource-limited settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. THE MECHANISM OF THE INHIBITION OF HEMOLYSIS

    PubMed Central

    Ponder, Eric

    1946-01-01

    This paper is concerned with hemolytic systems containing sodium taurocholate, sodium glycocholate, or saponin, and either human red cells or the ghosts (stromata) of human red cells. The lysins are allowed to react with the cells for a short time (1 minute or less), and with the ghosts for a long time (4 hours), and the quantity of lysin remaining in the bulk phase, after the removal of the cells or of the ghosts, is found by (a) colorimetric methods, and (b) methods which measure its hemolytic activity. In the experiments in which the lysins react with the cells for a time so short that none of them is hemolyzed, it is found: (1) that the suspension medium of a cell suspension contains inhibitory substances which render a small amount of the lysin non-lytic, (2) that on the addition of the lysin to the cell suspension, a further and much larger amount of lysin is rendered non-lytic, and (3) that the quantity of chromogenic material in the bulk phase, after the lysin has been in contact with the cells and the latter have been removed, is substantially the same as that initially present. No appreciable quantity of lysin, accordingly, accumulates in increased concentration at the cell surfaces. The results of the colorimetric determinations show that the apparent disappearance of lysin from the bulk phase, once thought to be due to an accumulation of lysin at the cell surfaces, is the result either of an inhibitory process or of a sudden utilization of lysin unrecognized by existing theory. In the experiments in which the lysins react with stromata for 4 hours, it is found: (1) that the suspension medium of a stroma suspension contains inhibitory substances which render some of the lysin non-lytic, (2) that when the lysin reacts with the stromata over a period of time, a much greater quantity of lysin is rendered non-lytic, and (3) that the concentration of chromogenic material in the bulk phase of the lysin-stroma system, after 4 hours of reaction, is substantially the same as it was initially. The observations can be accounted for by supposing that the lysin molecules are as chromogenic after reacting with the cell components as before, and by their not being bound to the cell or to the ghost, but diffusing back, combined with the components with which they have reacted, into the bulk phase. Such a process would have similarities to the process of penetration and breakdown of mixed protein-lipoid films. Because it is not possible at present to decide how much of the lysin is rendered inert because of utilization in a reaction with cell components, and how much because of the effect of inhibitory substances, difficulties and uncertainties arise in connection with the expressions which have been used to describe the kinetics of hemolysis. PMID:19873457

  19. On the feasibility of a CENTA-based biosensor to measure antibiotics concentration in milk

    NASA Astrophysics Data System (ADS)

    Ferrari, Luca; Rovati, Luigi; Costi, Maria Paola; Venturelli, Alberto; Luciani, Rosaria; Cattini, Stefano

    2017-07-01

    In veterinary practice antibiotics are used and abused all over the world both to treat diseases and prevent infections and, to increase feed efficiency thus promoting growth in food producing animals. With more than 30 years history, β-lactam antibiotics are nowadays one of the most important group of antibiotics in veterinary medicine. In this paper we investigate the possibility to realize a measurement method suitable for field testing and we propose a competitive biosensor based on a relatively low-cost chromogenic cephalosporin (CENTA) for the quantitative analysis of β-lactams concentration in milk. In particular, the reported preliminary study has been focused on cloxacillin and the reported results indicates that the method is potentially able to detect cloxacillin at a concentration of about one order of magnitude lower than the maximal residue limits (MRL) set by the European Commission.

  20. Validated flow-injection method for rapid aluminium determination in anti-perspirants.

    PubMed

    López-Gonzálvez, A; Ruiz, M A; Barbas, C

    2008-09-29

    A flow-injection (FI) method for the rapid determination of aluminium in anti-perspirants has been developed. The method is based on the spectrophotometric detection at 535nm of the complex formed between Al ions and the chromogenic reagent eriochrome cyanine R. Both the batch and FI methods were validated by checking the parameters included in the ISO-3543-1 regulation. Variables involved in the FI method were optimized by using appropriate statistical tools. The method does not exhibit interference from other substances present in anti-perspirants and it shows a high precision with a R.S.D. value (n=6) of 0.9%. Moreover, the accuracy of the method was evaluated by comparison with a back complexometric titration method, which is currently used for routine analysis in pharmaceutical laboratories. The Student's t-test showed that the results obtained by both methods were not significantly different for a significance level of 95%. A response time of 12s and a sample analysis time, by performing triplicate injections, of 60s were achieved. The analytical figures of merit make the method highly appropriate to substitute the time-consuming complexometric method for this kind of analysis.

  1. Evaluation of the Q analyzer, a new cap-piercing fully automated coagulometer with clotting, chromogenic, and immunoturbidometric capability.

    PubMed

    Kitchen, Steve; Woolley, Anita

    2013-01-01

    The Q analyzer is a recently launched fully automated photo-optical analyzer equipped with primary tube cap-piercing and capable of clotting, chromogenic, and immunoturbidometric tests. The purpose of the present study was to evaluate the performance characteristics of the Q analyzer with reagents from the instrument manufacturer. We assessed precision and throughput when performing coagulation screening tests, prothrombin time (PT)/international normalized ratio (INR), activated partial thromboplastin time (APTT), and fibrinogen assay by Clauss assay. We compared results with established reagent instrument combinations in widespread use. Precision of PT/INR and APTT was acceptable as indicated by total precision of around 3%. The time to first result was 3  min for an INR and 5  min for PT/APTT. The system produced 115 completed samples per hour when processing only INRs and 60 samples (120 results) per hour for PT/APTT combined. The sensitivity of the DG-APTT Synth/Q method to mild deficiency of factor VIII (FVIII), IX, and XI was excellent (as indicated by APTTs being prolonged above the upper limit of the reference range). The Q analyzer was associated with high precision, acceptable throughput, and good reliability. When used in combination with DG-PT reagent and manufacturer's instrument-specific international sensitivity index, the INRs obtained were accurate. The Q analyzer with DG-APTT Synth reagent demonstrated good sensitivity to isolated mild deficiency of FVIII, IX, and XI and had the advantage of relative insensitivity to mild FXII deficiency. Taken together, our data indicate that the Q hemostasis analyzer was suitable for routine use in combination with the reagents evaluated.

  2. Differentiation of Yersinia enterocolitica biotype 1A from pathogenic Yersinia enterocolitica biotypes by detection of β-glucosidase activity: comparison of two chromogenic culture media and Vitek2.

    PubMed

    Karhukorpi, Jari; Päivänurmi, Marjut

    2014-01-01

    Aesculin hydrolysis (ESC) is one of the key reactions in differentiating pathogenic Yersinia enterocolitica biotypes 1B, 2, 3, 4 and 5 from the less-pathogenic biotype 1A. Because the ESC reaction is caused by β-glucosidase (βGLU) activity of the bacteria, we studied whether two commonly used methods (BBL CHROMagar Orientation and Vitek2 Gram-negative identification card) could be used in assessing βGLU activity of 74 Yersinia strains. Both methods were sensitive (100 % and 97 %) and specific (100 % and 100 %) in differentiating βGLU-positive YE BT1A from βGLU-negative Y. enterocolitica biotypes. For a subset of strains (n = 69), a new selective CHROMagar Yersinia showed excellent agreement with the strains' βGLU activity. Thus all the methods evaluated in this study may be used to differentiate between YE BT1A and other Y. enterocolitica biotypes.

  3. A chromogenic and fluorogenic rhodol-based chemosensor for hydrazine detection and its application in live cell bioimaging.

    PubMed

    Tiensomjitr, Khomsan; Noorat, Rattha; Chomngam, Sinchai; Wechakorn, Kanokorn; Prabpai, Samran; Kanjanasirirat, Phongthon; Pewkliang, Yongyut; Borwornpinyo, Suparerk; Kongsaeree, Palangpon

    2018-04-15

    A rhodol-based fluorescent probe has been developed as a selective hydrazine chemosensor using levulinate as a recognition site. The rhodol levulinate probe (RL) demonstrated high selectivity and sensitivity toward hydrazine among other molecules. The chromogenic response of RL solution to hydrazine from colorless to pink could be readily observed by the naked eye, while strong fluorescence emission could be monitored upon excitation at 525 nm. The detection process occurred via a ring-opening process of the spirolactone initiated by hydrazinolysis, triggering the fluorescence emission with a 53-fold enhancement. The probe rapidly reacted with hydrazine in aqueous medium with the detection limit of 26 nM (0.83 ppb), lower than the threshold limit value (TLV) of 10 ppb suggested by the U.S. Environmental Protection Agency. Furthermore, RL-impregnated paper strips could detect hydrazine vapor. For biological applicability of RL, its membrane-permeable property led to bioimaging of hydrazine in live HepG2 cells by confocal fluorescence microscopy. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Zn(II)-cyclam based chromogenic sensors for recognition of ATP in aqueous solution under physiological conditions and their application as viable staining agents for microorganism.

    PubMed

    Mahato, Prasenjit; Ghosh, Amrita; Mishra, Sanjiv K; Shrivastav, Anupama; Mishra, Sandhya; Das, Amitava

    2011-05-02

    Two chromogenic complexes, L.Zn (where L is (E)-4-((4-(1,4,8,11-tetraazacyclotetradecan-1-ylsulfonyl)phenyl)diazenyl)-N,N-dimethylaniline) and its [2]pseudorotaxane form (α-CD.L.Zn), were found to bind preferentially to adenosine triphosphate (ATP), among all other common anions and biologically important phosphate (AMP, ADP, pyrophosphate, and phosphate) ions in aqueous HEPES buffer medium of pH 7.2. Studies with live cell cultures of prokaryotic microbes revealed that binding of these two reagents to intercellular ATP, produced in situ, could be used in delineating the gram-positive and the gram-negative bacteria. More importantly, these dyes were found to be nontoxic to living microbes (eukaryotes and prokaryotes) and could be used for studying the cell growth dynamics. Binding to these two viable staining agents to intercellular ATP was also confirmed by spectroscopic studies on cell growth in the presence of different respiratory inhibitors that influence the intercellular ATP generation. © 2011 American Chemical Society

  5. Preparation of a Superhydrophobic and Peroxidase-like Activity Array Chip for H2O2 Sensing by Surface-Enhanced Raman Scattering.

    PubMed

    Yu, Zhi; Park, Yeonju; Chen, Lei; Zhao, Bing; Jung, Young Mee; Cong, Qian

    2015-10-28

    In this paper, we propose a novel and simple method for preparing a dual-biomimetic functional array possessing both superhydrophobic and peroxidase-like activity that can be used for hydrogen peroxide (H2O2) sensing. The proposed method is an integration innovation that combines the above two properties and surface-enhanced Raman scattering (SERS). We integrated a series of well-ordered arrays of Au points (d = 1 mm) onto a superhydrophobic copper (Cu)/silver (Ag) surface by replicating an arrayed molybdenum template. Instead of using photoresists and the traditional lithography method, we utilized a chemical etching method (a substitution reaction between Cu and HAuCl4) with a Cu/Ag superhydrophobic surface as the barrier layer, which has the benefit of water repellency. The as-prepared Au points were observed to possess peroxidase-like activity, allowing for catalytic oxidation of the chromogenic molecule o-phenylenediamine dihydrochloride (OPD). Oxidation was evidenced by a color change in the presence of H2O2, which allows the array chip to act as an H2O2 sensor. In this study, the water repellency of the superhydrophobic surface was used to fabricate the array chip and increase the local reactant concentration during the catalytic reaction. As a result, the catalytic reaction occurred when only 2 μL of an aqueous sample (OPD/H2O2) was placed onto the Au point, and the enzymatic product, 2,3-diaminophenazine, showed a SERS signal distinguishable from that of OPD after mixing with 2 μL of colloidal Au. Using the dual-biomimetic functional array chip, quantitative analysis of H2O2 was performed by observing the change in the SERS spectra, which showed a concentration-dependent behavior for H2O2. This method allows for the detection of H2O2 at concentrations as low as 3 pmol per 2 μL of sample, which is a considerable advantage in H2O2 analysis. The as-prepared substrate was convenient for H2O2 detection because only a small amount of sample was required in each analysis. Highly sensitive detection was realized using SERS. Therefore, this chip was shown to exhibit significant potential for applications in bioanalysis.

  6. Teat apex colonization with coagulase-negative Staphylococcus species before parturition: Distribution and species-specific risk factors.

    PubMed

    De Visscher, A; Piepers, S; Haesebrouck, F; De Vliegher, S

    2016-02-01

    Coagulase-negative staphylococci (CNS) are the main cause of bovine intramammary infections and are also abundantly present in extramammary habitats such as teat apices. Teat apex colonization (TAC) with CNS has already been explored in lactating dairy cows at the species level, whereas this is not true for dry cows and end-term heifers. Therefore, the aim of this observational study was to describe CNS TAC in nonlactating dairy cows and end-term heifers in Flemish dairy herds and to identify associated risk factors at the herd, cow, and quarter level. All CNS were molecularly identified to the species level using transfer RNA intergenic spacer PCR (tDNA-PCR) and sequencing of the 16S rRNA gene, allowing for species-specific statistical analyses using multivariable, multilevel logistic regression. Staphylococcus devriesei, Staphylococcus chromogenes, Staphylococcus haemolyticus, and Staphylococcus equorum were the most frequently isolated species. Staphylococcus chromogenes was the sole species colonizing teat apices of cows and heifers in all herds, whereas large between-herd differences were observed for the other species. Teat apices of red and white Holstein Friesians, of quarters dried off without an internal teat sealer, and swabbed in months with lower precipitation and higher ambient temperature were significantly more likely to be colonized by S. devriesei. Slightly dirty teat apices and teat apices swabbed in months with lower precipitation had higher odds of being colonized by S. chromogenes, whereas teat apices sampled in months with lower precipitation and higher ambient temperature were more likely to be colonized by S. haemolyticus. Dirty teat apices and teat apices swabbed in months with lower ambient temperature in combination with low precipitation had higher odds of being colonized by S. equorum. Diverse factors explaining CNS TAC, yet mostly related to humidity, ambient temperature, and hygiene, substantiate differences in epidemiological behavior and ecology between species. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Evaluation of five selective media for the detection of Pseudomonas aeruginosa using a strain panel from clinical, environmental and industrial sources.

    PubMed

    Weiser, Rebecca; Donoghue, Denise; Weightman, Andrew; Mahenthiralingam, Eshwar

    2014-04-01

    Isolation and correct identification of the opportunistic pathogen and industrial contaminant Pseudomonas aeruginosa are very important and numerous selective media are available for this purpose. A novel comparison of five selective media having positive (acetamide-based agars), negative (Pseudomonas CN selective agar [Oxoid Ltd.] and Pseudomonas Isolation agar [Sigma-Aldrich Company Ltd.]) and chromogenic (chromID® P. aeruginosa [bioMérieux]) selection strategies was performed using a systematically designed bacterial test panel (58 P. aeruginosa and 90 non-P. aeruginosa strains including those commonly misidentified as P. aeruginosa by culture-dependent techniques). Standardised inocula were added to the selective media and the results were recorded after 24 and 72h. After 72h of incubation at 37°C chromID® P. aeruginosa displayed the highest specificity (70%) and had good sensitivity (95%), although the sensitivity was negatively impacted by the large variation in colour of P. aeruginosa colonies, which hampered interpretation. Both media containing inhibitory selective agents performed very similarly, both having 100% sensitivity and a specificity of approximately 30%. Raising the incubation temperature to 42°C increased the specificity of Pseudomonas CN selective agar and Pseudomonas isolation agar (61% and 47% respectively after 72h), but increased the number of false positives encountered with the chromogenic medium, decreasing its specificity to 68% after 72h. Growth on the acetamide agars was weak for all strains and it was often difficult to determine whether true growth had occurred. This, compounded by the low specificity of the acetamide agars (<26%), suggested they were less suitable for application to clinical or industrial settings without further modification. Overall, the chromogenic agar was the most selective but further consideration is required to optimise interpretation of results. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. [Survey on the medical mycology processes to the members of the French Society for Medical Mycology].

    PubMed

    Kauffmann-Lacroix, C; Albouy-Llaty, M; Migeot, V; Contet-Audonneau, N

    2011-09-01

    The objective of the survey was to describe the practices of clinical laboratories in terms of cultures in medical mycology. We have implemented this project within the members of the French Society for Medical Mycology (SFMM) to evaluate the analytical processes of the mycological examination in our laboratories. This preliminary study would help to suggest the future French guidelines. A questionnaire regarding the processing of mycology analysis was sent to the 227 members of the SFMM in 2009. The data involved 21 types of samples, direct microscopic examination with or without colouring and the reagents, the number of culture media, the types of media (Sabouraud, Sabouraud antibiotic, Sabouraud cycloheximide and chromogenic medium), temperature and duration of the incubation (days) and the existence of a first result before the end of the incubation period. The analytical processes were compared to an accredited laboratory according to EN ISO 15189. A great heterogeneity was observed in the 36 forms from 27 (75%) laboratories belonging to university hospitals among the 38 existing in France. As for deep samples, two microscopic exams were performed, only one was usually done. A more sensitive technique was preferred to the wet-mount for some samples. Routine samples are often inoculated on a chromogenic media. For deep samples two medium are inoculated (chromogenic media, Sabouraud and antibiotics). If the temperature of incubation is unique, 30°C was chosen. A temperature of 37°C was preferred for samples where Candida spp. is selected. When there are two temperatures of incubation, 27°C and 37°C were preferred. Each biologist can compare his proceedings to the other laboratories and to a laboratory already accredited. The question is to find the best strategies for each medical mycology specimen. They will aid the process of accreditation according to EN ISO 15189, which now applies in all laboratories in Europe. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  9. Application of immunogold-silver staining and immunoenzymatic methods in multiple labelling of human pancreatic Langerhans islet cells.

    PubMed

    Krenács, T; Lászik, Z; Dobó, E

    1989-01-01

    The use of immunogold-silver staining (IGSS) combined with immunoperoxidase and/or immunoalkaline phosphatase methods for the simultaneous demonstration of pancreatic islet cell hormones on routinely fixed paraffin-embedded human tissue sections was examined. If IGSS was applied first, the black colour of silver-enhanced colloidal gold on doubly immunostained sections contrasted with the colours of most of the chromogens used generally in the 2 immunoenzymatic methods. If IGSS was followed by immunoalkaline phosphatase and immunoperoxidase techniques in optional sequence, 3 different hormone-containing cell types could be stained simultaneously without non-specific cross-reactions. IGSS and immunoalkaline phosphatase methods, together with 2 kinds of non-cross-reacting immunoperoxidase systems, permitted the detection of 4 distinct antigens on the same tissue section. Multiple immunohistochemical labelling of the endocrine pancreas provides an opportunity for the correct and rapid analysis of the topographic and morphometric relationships between different hormone-producing cell populations under both normal and pathological conditions. IGSS is of great potential for the simultaneous immunolabelling of antigens situated within separate cells.

  10. Tunable Optical Polymer Systems

    DTIC Science & Technology

    2004-10-29

    effected , the amount of energy required to achieve optical tunability, satisfactory color contrasts, durability, the processability of the chromogenic...moieties. However, this interaction is not strong enough to cause a pronounced effect in its photophysics. As a result of this slight interaction...oxidation accompanied by a color change. The reduction behavior is unstable and causes loss of the electrochromic effect . The PPTZPQ

  11. Differential specificity of selective culture media for enumeration of pathogenic vibrios: advantages and limitations of multi-plating methods.

    PubMed

    Nigro, Olivia D; Steward, Grieg F

    2015-04-01

    Plating environmental samples on vibrio-selective chromogenic media is a commonly used technique that allows one to quickly estimate concentrations of putative vibrio pathogens or to isolate them for further study. Although this approach is convenient, its usefulness depends directly on how well the procedure selects against false positives. We tested whether a chromogenic medium, CHROMagar Vibrio (CaV), used alone (single-plating) or in combination (double-plating) with a traditional medium thiosulfate-citrate-bile-salts (TCBS), could improve the discrimination among three pathogenic vibrio species (Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus) and thereby decrease the number of false-positive colonies that must be screened by molecular methods. Assays were conducted on water samples from two estuarine environments (one subtropical, one tropical) in a variety of seasonal conditions. The results of the double-plating method were confirmed by PCR and 16S rRNA sequencing. Our data indicate that there is no significant difference in the false-positive rate between CaV and TCBS when using a single-plating technique, but determining color changes on the two media sequentially (double-plating) reduced the rate of false positive identification in most cases. The improvement achieved was about two-fold on average, but varied greatly (from 0- to 5-fold) and depended on the sampling time and location. The double-plating method was most effective for V. vulnificus in warm months, when overall V. vulnificus abundance is high (false positive rates as low as 2%, n=178). Similar results were obtained for V. cholerae (minimum false positive rate of 16%, n=146). In contrast, the false positive rate for V. parahaemolyticus was always high (minimum of 59%, n=109). Sequence analysis of false-positive isolates indicated that the majority of confounding isolates are from the Vibrionaceae family, however, members of distantly related bacterial groups were also able to grow on vibrio-selective media, even when using the double-plating method. In conclusion, the double-plating assay is a simple means to increase the efficiency of identifying pathogenic vibrios in aquatic environments and to reduce the number of molecular assays required for identity confirmation. However, the high spatial and temporal variability in the performance of the media mean that molecular approaches are still essential to obtain the most accurate vibrio abundance estimates from environmental samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Multiparametric comparison of chromogenic-based culture methods used to assess the microbiological quality of drinking water and the mFC method combined with a molecular confirmation procedure.

    PubMed

    Maheux, Andrée F; Dion-Dupont, Vanessa; Bisson, Marc-Antoine; Bouchard, Sébastien; Jubinville, Éric; Nkuranga, Martine; Rodrigue, Lynda; Bergeron, Michel G; Rodriguez, Manuel J

    2015-03-01

    MI agar and Colilert(®), as well as mFC agar combined with an Escherichia coli-specific molecular assay (mFC + E. coli rtPCR), were compared in terms of their sensitivity, ease of use, time to result and affordability. The three methods yielded a positive E. coli signal for 11.5, 10.8, and 11.5% of the 968 well water samples tested, respectively. One hundred and thirty-six (136) samples gave blue colonies on mFC agar and required confirmation. E. coli-specific rtPCR showed false-positive results in 23.5% (32/136) of cases. In terms of ease of use, Colilert was the simplest method to use while the MI method provided ease of use comparable to all membrane filtration methods. However, the mFC + E. coli rtPCR assay required highly trained employees for confirmation purposes. In terms of affordability, and considering contamination rate of well water samples tested, the Colilert method and the mFC + E. coli rtPCR assay were at least five times more costly than the MI agar method. Overall, compared with the other two methods tested, the MI agar method offers the most advantages to assess drinking water quality.

  13. NEW MEDIUM FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND ESCHERICHIA COLI IN WATER (PUBLISHED ERRATUM APPEARS IN APP ENVIRON MICROBIOL 1993 DEC;59(12):4378)

    EPA Science Inventory

    A new membrane filter agar medium (MI agar) containing a chromogen, indoxyl-beta-D-glucuronide, and a fluorogen, 4-methylumbelliferyl-beta-D-galactopyranoside, was developed to simultaneously detect and enumerate Escherichia coli and total coliforms (TC) in water samples on the b...

  14. Adaptive chromogenic materials and devices

    NASA Astrophysics Data System (ADS)

    Sixou, Pierre; Guillard, H.; Labonne, L.; Gandolfo, V.

    2003-03-01

    Electrically controllable glasses can be used to control daylight and solar energy in buildings and in automotives in order to improve quality of life and to save energy spent on lighting, cooling and heating. The paper discusses the case of switchable glazings using liquid crystal/polymer micro-composites. A comparison with other technologies (like inorganic electrochromics, thermotropic gels and dispersed particles) is drawn.

  15. Hyperspectral imaging for differentiating colonies of non-O157 shiga-toxin producing echerichia coli (STEC) serogroups on spread plates of pure cultures

    USDA-ARS?s Scientific Manuscript database

    Direct plating onto solid agar media has been widely used in microbiology laboratories for presumptive-positive pathogen detection in spite of the fact that it is often subjective, labor intensive and time consuming. Rainbow agar is a selective and chromogenic medium that helps to detect pathogenic ...

  16. [Early kinetics of Toxoplasma gondii infection in mice infected intragastrically with tachyzoites by chromogenic in situ hybridization targeting SAG2 mRNA].

    PubMed

    Meng, Xiao-li; Ma, Xiao-ming; Yin, Guo-rong; Liu, Hong-li; Yin, Li-tian; Shen, Jin-yan; Wang, Hai-long

    2010-04-01

    To observe the early kinetics of Toxoplasma gondii infection in mice inoculated with tachyzoites of RH strain. Twenty BALB/c mice were administered intragastrically with tachyzoites of RH strain (2 x 10(4)/mice). Parasite burdens in mesenteric lymph node (MLN), liver, spleen, lung and brain were determined by chromogenic in situ hybridization targeting SAG2 mRNA at 1, 2, 4, 6 and 8 days postinfection. Five mice were inoculated with PBS as blank control. The MLN, liver and spleen were the first organs where tachyzoites were found on the first day after infection, followed by the lungs on the 4th day and the brain on the 6th day. On days 6 to 8 after infection, there was a significant difference on parasite load among the tissues (P < 0.05), and the parasite load in MLN was highest, followed by that of liver, spleen, lungs and brain. The number of tachyzoites in various tissues was time-dependent. T. gondii tachyzoites were first detected in MLN, liver and spleen, then in the lungs, and finally in the brain. The number of tachyzoites in the MLNs increased more rapidly.

  17. Monitoring of chicken meat freshness by means of a colorimetric sensor array.

    PubMed

    Salinas, Yolanda; Ros-Lis, José V; Vivancos, José-L; Martínez-Máñez, Ramón; Marcos, M Dolores; Aucejo, Susana; Herranz, Nuria; Lorente, Inmaculada

    2012-08-21

    A new optoelectronic nose to monitor chicken meat ageing has been developed. It is based on 16 pigments prepared by the incorporation of different dyes (pH indicators, Lewis acids, hydrogen-bonding derivatives, selective probes and natural dyes) into inorganic materials (UVM-7, silica and alumina). The colour changes of the sensor array were characteristic of chicken ageing in a modified packaging atmosphere (30% CO(2)-70% N(2)). The chromogenic array data were processed with qualitative (PCA) and quantitative (PLS) tools. The PCA statistical analysis showed a high degree of dispersion, with nine dimensions required to explain 95% of variance. Despite this high dimensionality, a tridimensional representation of the three principal components was able to differentiate ageing with 2-day intervals. Moreover, the PLS statistical analysis allows the creation of a model to correlate the chromogenic data with chicken meat ageing. The model offers a PLS prediction model for ageing with values of 0.9937, 0.0389 and 0.994 for the slope, the intercept and the regression coefficient, respectively, and is in agreement with the perfect fit between the predicted and measured values observed. The results suggest the feasibility of this system to help develop optoelectronic noses that monitor food freshness.

  18. Cu0.89Zn0.11O, A New Peroxidase-Mimicking Nanozyme with High Sensitivity for Glucose and Antioxidant Detection.

    PubMed

    Nagvenkar, Anjani P; Gedanken, Aharon

    2016-08-31

    Nanomaterial-based enzyme mimetics (nanozymes) is an emerging field of research that promises to produce alternatives to natural enzymes for a variety of applications. The search for the most cost-effective and efficient inorganic nanomaterials, such as metal oxides, cannot be won by pristine CuO. However, unlike CuO, the Zn-doped CuO (Zn-CuO) nanoparticles reported in this paper reveal superior peroxidase-like enzyme activity. This places Zn-CuO in a good position to participate in a range of activities aimed at developing diverse enzyme applications. The peroxidase-like activity was tested and confirmed against various chromogenic substrates in the presence of H2O2 and obeyed the Michaelis-Menten enzymatic pathway. The mechanism of enhanced enzymatic activity was proved by employing terephthalic acid as a fluorescence probe and by electron spin resonance. The nanozyme, when tested for the detection of glucose, showed a substantial enhancement in the detection selectivity. The limit of detection (LOD) was also decreased reaching a limit as low as 0.27 ppm. Such a low LOD has not been reported so far for the metal oxides without any surface modifications. Moreover, the nanozyme (Zn-CuO) was utilized to detect the three antioxidants tannic acid, tartaric acid, and ascorbic acid and the relative strength of their antioxidant capacity was compared.

  19. Role of human amnion-derived mesenchymal stem cells in promoting osteogenic differentiation by influencing p38 MAPK signaling in lipopolysaccharide -induced human bone marrow mesenchymal stem cells.

    PubMed

    Wang, Yuli; Wu, Hongxia; Shen, Ming; Ding, Siyang; Miao, Jing; Chen, Ning

    2017-01-01

    Periodontitis is a chronic inflammatory disease induced by bacterial pathogens, which not only affect connective tissue attachments but also cause alveolar bone loss. In this study, we investigated the anti-inflammatory effects of Human amnion-derived mesenchymal stem cells (HAMSCs) on human bone marrow mesenchymal stem cells (HBMSCs) under lipopolysaccharide (LPS)-induced inflammatory conditions. Proliferation levels were measured by flow cytometry and immunofluorescence staining of 5-ethynyl-2'-deoxyuridine (EdU). Osteoblastic differentiation and mineralization were investigated using chromogenic alkaline phosphatase activity (ALP) activity substrate assays, Alizarin red S staining, and RT-PCR analysis of HBMSCs osteogenic marker expression. Oxidative stress induced by LPS was investigated by assaying reactive oxygen species (ROS) level and superoxide dismutase (SOD) activity. Here, we demonstrated that HAMSCs increased the proliferation, osteoblastic differentiation, and SOD activity of LPS-induced HBMSCs, and down-regulated the ROS level. Moreover, our results suggested that the activation of p38 MAPK signal transduction pathway is essential for reversing the LPS-induced bone-destructive processes. SB203580, a selective inhibitor of p38 MAPK signaling, significantly suppressed the anti-inflammatory effects in HAMSCs. In conclusion, HAMSCs show a strong potential in treating inflammation-induced bone loss by influencing p38 MAPK signaling. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Platelet-Derived Short-Chain Polyphosphates Enhance the Inactivation of Tissue Factor Pathway Inhibitor by Activated Coagulation Factor XI.

    PubMed

    Puy, Cristina; Tucker, Erik I; Ivanov, Ivan S; Gailani, David; Smith, Stephanie A; Morrissey, James H; Gruber, András; McCarty, Owen J T

    2016-01-01

    Factor (F) XI supports both normal human hemostasis and pathological thrombosis. Activated FXI (FXIa) promotes thrombin generation by enzymatic activation of FXI, FIX, FX, and FV, and inactivation of alpha tissue factor pathway inhibitor (TFPIα), in vitro. Some of these reactions are now known to be enhanced by short-chain polyphosphates (SCP) derived from activated platelets. These SCPs act as a cofactor for the activation of FXI and FV by thrombin and FXIa, respectively. Since SCPs have been shown to inhibit the anticoagulant function of TFPIα, we herein investigated whether SCPs could serve as cofactors for the proteolytic inactivation of TFPIα by FXIa, further promoting the efficiency of the extrinsic pathway of coagulation to generate thrombin. Purified soluble SCP was prepared by size-fractionation of sodium polyphosphate. TFPIα proteolysis was analyzed by western blot. TFPIα activity was measured as inhibition of FX activation and activity in coagulation and chromogenic assays. SCPs significantly accelerated the rate of inactivation of TFPIα by FXIa in both purified systems and in recalcified plasma. Moreover, platelet-derived SCP accelerated the rate of inactivation of platelet-derived TFPIα by FXIa. TFPIα activity was not affected by SCP in recalcified FXI-depleted plasma. Our data suggest that SCP is a cofactor for TFPIα inactivation by FXIa, thus, expanding the range of hemostatic FXIa substrates that may be affected by the cofactor functions of platelet-derived SCP.

  1. The purification and characterization of an 88-kDa Porphyromonas endodontalis 35406 protease.

    PubMed

    Rosen, G; Shoshani, M; Naor, R; Sela, M N

    2001-12-01

    A Porphyromonas endodontalis ATCC 35406 protease was purified from Triton X-114 cell extracts by preparative SDS-PAGE followed by electroelution. The purified enzyme exhibits a molecular size of 88 kDa and was dissociated into two polypeptides of 43 and 41 kDa upon heating in the presence of sodium dodecyl sulfate with or without a reducing agent. The protease (pH optimum 7.5-8.0) degraded the extracellular matrix proteins fibrinogen and fibronectin. Collagen IV was also degraded at 37 degrees C but not at 28 degrees C. The protease also cleaved the bioactive peptide angiotensin at amino acid residue phenylalanine-8 and tyrosine-4 but failed to hydrolyze bradykinin, vasopressin and synthetic chromogenic substrates with phenylalanine or tyrosine at the P1 position. In addition, two peptidases were detected in P. endodontalis cells: a proline aminopeptidase that remained associated with the cell pellet after detergent extraction and peptidase/s that partitioned into the Triton X-114 phase after phase separation and degraded the bioactive peptides bradykinin and vasopressin. These P. endodontalis peptidases and proteases may play an important role in both the nutrition and pathogenicity of these assacharolytic microorganisms. The inactivation of bioactive peptides and degradation of extracellular matrix proteins by bacterial enzymes may contribute to the damage of host tissues accompanied with endodontic infections.

  2. A High-Throughput, Precipitating Colorimetric Sandwich ELISA Microarray for Shiga Toxins

    PubMed Central

    Gehring, Andrew; He, Xiaohua; Fratamico, Pina; Lee, Joseph; Bagi, Lori; Brewster, Jeffrey; Paoli, George; He, Yiping; Xie, Yanping; Skinner, Craig; Barnett, Charlie; Harris, Douglas

    2014-01-01

    Shiga toxins 1 and 2 (Stx1 and Stx2) from Shiga toxin-producing E. coli (STEC) bacteria were simultaneously detected with a newly developed, high-throughput antibody microarray platform. The proteinaceous toxins were immobilized and sandwiched between biorecognition elements (monoclonal antibodies) and pooled horseradish peroxidase (HRP)-conjugated monoclonal antibodies. Following the reaction of HRP with the precipitating chromogenic substrate (metal enhanced 3,3-diaminobenzidine tetrahydrochloride or DAB), the formation of a colored product was quantitatively measured with an inexpensive flatbed page scanner. The colorimetric ELISA microarray was demonstrated to detect Stx1 and Stx2 at levels as low as ~4.5 ng/mL within ~2 h of total assay time with a narrow linear dynamic range of ~1–2 orders of magnitude and saturation levels well above background. Stx1 and/or Stx2 produced by various strains of STEC were also detected following the treatment of cultured cells with mitomycin C (a toxin-inducing antibiotic) and/or B-PER (a cell-disrupting, protein extraction reagent). Semi-quantitative detection of Shiga toxins was demonstrated to be sporadic among various STEC strains following incubation with mitomycin C; however, further reaction with B-PER generally resulted in the detection of or increased detection of Stx1, relative to Stx2, produced by STECs inoculated into either axenic broth culture or culture broth containing ground beef. PMID:24921195

  3. Venom Protein C activators as diagnostic agents for defects of protein C System.

    PubMed

    Ramzan, Faiqah; Asmat, Andleeb

    2018-06-18

    Background Protein C is a vitamin K dependent plasma zymogen. It prevents clotting by inhibiting clotting by inactivating factor V and factor VIII. Protein C activation pathway involves three steps: (i) Activation of protein C; (ii) Inhibition of coagulation through inactivating factor V and VIII by activated protein C and (iii) Inhibition of activated protein C by plasma protease inhibitors specific for this enzyme. Proteinases converts the zymogen Protein C (PC) of vertebrates into activated PC, which has been detected in several snake venoms. Most PC activators have been purified from venom of snake species belonging to the genera of the Agkistrodon complex. Unlike the physiological thrombin-catalyzed PC activation reaction which requires thrombomodulin as a cofactor, most snake venom activators directly convert the zymogen PC into the catalytically active form which can easily be determined by means of coagulation or chromogenic substrate techniques. Conclusion The fast-acting PC activator Protac® from Agkistrodon contortrix (southern copperhead snake) venom has been found to have broad application in diagnostic practice for the determination of disorders in the PC pathway. Recently, screening assays for the PC pathway have been introduced, based on the observation that the PC pathway is probably the most important physiological barrier against thrombosis. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  4. A Simple Automated Method for the Determination of Nitrate and Nitrite in Infant Formula and Milk Powder Using Sequential Injection Analysis

    PubMed Central

    Pistón, Mariela; Mollo, Alicia; Knochen, Moisés

    2011-01-01

    A fast and efficient automated method using a sequential injection analysis (SIA) system, based on the Griess, reaction was developed for the determination of nitrate and nitrite in infant formulas and milk powder. The system enables to mix a measured amount of sample (previously constituted in the liquid form and deproteinized) with the chromogenic reagent to produce a colored substance whose absorbance was recorded. For nitrate determination, an on-line prereduction step was added by passing the sample through a Cd minicolumn. The system was controlled from a PC by means of a user-friendly program. Figures of merit include linearity (r2 > 0.999 for both analytes), limits of detection (0.32 mg kg−1 NO3-N, and 0.05 mg kg−1 NO2-N), and precision (sr%) 0.8–3.0. Results were statistically in good agreement with those obtained with the reference ISO-IDF method. The sampling frequency was 30 hour−1 (nitrate) and 80 hour−1 (nitrite) when performed separately. PMID:21960750

  5. Selective Discrimination of Key Enzymes of Pathogenic and Nonpathogenic Bacteria on Autonomously Reporting Shape-Encoded Hydrogel Patterns.

    PubMed

    Jia, Zhiyuan; Sukker, Issa; Müller, Mareike; Schönherr, Holger

    2018-02-14

    This work reports on a new approach to rapidly and selectively detect and discriminate enzymes of pathogenic from those of nonpathogenic bacteria using a patterned autonomously reporting hydrogel on a transparent support, in which the selectivity has been encoded by the pattern shape to enable facile detection by a color change at one single wavelength. In particular, enzyme-responsive chitosan hydrogel layers that report the presence of the enzymes β-glucuronidase (β-Gus) and β-galactosidase (β-Gal), produced by the nonvirulent Escherichia coli K12 and the food-borne biosafety level 3 pathogen enterohemorrhagic E. coli, respectively, via the blue color of an indigo dye were patterned by two complementary strategies. The comparison of the functionalization of patterned chitosan patches on a solid support with two chromogenic substrates on one hand and the area-selective conjugation of the substrates on the other hand showed that the two characteristic enzymes could indeed be rapidly and selectively discriminated. The limits of detection of the highly stable sensing layers for an observation time of 60 min using a spectrophotometer correspond to enzyme concentrations of β-Gus and β-Gal of ≤5 and ≤3 nM, respectively, and to ≤62 and ≤33 nM for bare eye detection in nonoptimized sensor patches. These results confirm the applicability of this approach, which is compatible with the simple measurement of optical density at one single wavelength only as well as with parallel, multiplexed detection, to differentiate the enzymes secreted by a highly pathogenic E. coli from a nonpathogenic E. coli on the basis of specifically secreted enzymes. Hence, a general approach for the rapid and selective detection of enzymes of different bacterial species for potential applications in food safety as well as point-of-care microbiological diagnostics is described.

  6. Purification, substrate specificity, and classification of tripeptidyl peptidase II.

    PubMed

    Bålöw, R M; Tomkinson, B; Ragnarsson, U; Zetterqvist, O

    1986-02-15

    An extralysosomal tripeptide-releasing aminopeptidase was recently discovered in rat liver (Bålöw, R.-M., Ragnarsson, U., and Zetterqvist, O. (1983) J. Biol. Chem. 258, 11622-11628). In the present work this tripeptidyl peptidase is shown to occur in several rat tissues and in human erythrocytes. The erythrocyte enzyme was purified about 80,000-fold from a hemolysate while the rat liver enzyme was purified about 4,000-fold from a homogenate. Upon polyacrylamide gel electrophoresis in sodium dodecyl sulfate under reducing conditions more than 90% of the protein was represented by a polypeptide of Mr 135,000 in both cases. In addition, the two enzymes eluted at similar positions in the various chromatographic steps, showed similar specific activity, and had a pH optimum around 7.5. A tryptic pentadecapeptide from the alpha-chain of human hemoglobin, Val-Gly-Ala-His-Ala-Gly-Glu-Tyr-Gly-Ala-Glu-Ala-Leu-Glu-Arg, i.e. residues 17-31, was found to be sequentially cleaved by the erythrocyte enzyme into five tripeptides, beginning from the NH2 terminus. Chromogenic tripeptidylamides showed various rates of hydrolysis at pH 7.5. With Ala-Ala-Phe-4-methyl-7-coumarylamide, Km was 16 microM and Vmax 13 mumol min-1 . mg-1, comparable to the standard substrate Arg-Arg-Ala-Ser(32P)-Val-Ala values (Km 13 microM and Vmax 24 mumol . min-1 . mg-1). The tripeptidyl peptidase of human erythrocytes was classified as a serine peptidase from its irreversible inhibition by phenylmethanesulfonyl fluoride and diisopropyl fluorophosphate. The rate of inhibition was decreased by the presence of an efficient competitive inhibitor, Val-Leu-Arg-Arg-Ala-Ser-Val-Ala (Ki 1.5 microM). [3H]Diisopropylphosphate was incorporated to the extent of 0.7-0.9 mol/mol of Mr 135,000 subunit, which confirms the high purity of the enzyme.

  7. Short communication: Species group-specific predictors at the cow and quarter level for intramammary infection with coagulase-negative staphylococci in dairy cattle throughout lactation.

    PubMed

    De Visscher, A; Piepers, S; Supré, K; Haesebrouck, F; De Vliegher, S

    2015-08-01

    Coagulase-negative staphylococci (CNS) are frequently isolated from quarters with subclinical mastitis, teat apices, and the cows' environment. Virulence, ecology, epidemiological behavior, and effect on udder health vary between different CNS species. Staphylococcus chromogenes, Staph. simulans, and Staph. xylosus are frequently present in milk and have a more substantial effect on quarter milk somatic cell count than other species. Therefore, these species are considered the "more relevant" CNS. As species-specific factors associated with CNS intramammary infection (IMI) have not yet been identified and susceptibility for IMI differs between cows and quarters, this study aimed to identify predictors for CNS IMI at the cow and quarter level (some of them changing over time) with a specific focus on the aforementioned more relevant CNS. Precise data were available from a longitudinal study (3,052 observations from 344 quarters from 86 dairy cows belonging to 3 commercial dairy herds). All CNS were molecularly identified to the species level, and multivariable, multilevel logistic regression models taking into account the longitudinal nature of the data, were fit to study the likelihood of infection. Staphylococcus chromogenes, Staph. xylosus, and Staph. cohnii were the most frequently isolated species from CNS IMI in older cows, whereas Staph. chromogenes, Staph. xylosus, and Staph. simulans were the main species found in IMI in heifers. Quarters from heifers (as opposed to multiparous cows), from heifers and multiparous cows in third or fourth month in lactation (as opposed to early lactation, <60 d in milk), and with an increasing quarter milk SCC were more likely to be infected with the more relevant CNS species. Quarter milk SCC was identified as the sole statistically significant predictor for IMI with other CNS species, although the size of the effect was lower [odds ratio of 1.6 (1.4-1.9) vs. 2.1 (1.8-2.5)] than the effect for IMI with the more relevant CNS. As a strong herd effect was present, studying herd-level predictors is warranted. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots.

    PubMed

    Chen, Rui; Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua; Xiong, Yonghua

    2016-12-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H 2 O 2 ) and H 2 O 2 -sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H 2 O 2 and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H 2 O 2 , as well as the incubation time between H 2 O 2 and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10 2  CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10 3  CFU/mL to 1.18 × 10 6  CFU/mL were in the range of 65.88%-105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Sensitive and Selective Spectrophotometric Determination of Gabapentin in Capsules Using Two Nitrophenols as Chromogenic Agents

    PubMed Central

    Abdulrahman, Sameer A. M.; Basavaiah, Kanakapura

    2011-01-01

    Two simple and selective spectrophotometric methods have been proposed for the determination of gabapentin (GBP) in pure form and in capsules. Both methods are based on the proton transfer from the Lewis acid such as 2,4,6-trinitrophenol (picric acid; PA) or 2,4-dinitrophenol (2,4-DNP) to the primary amino group of GBP which works as Lewis base and formation of yellow ion-pair complexes. The ion-pair complexes formed show absorption maximum at 415 and 420 nm for PA and 2,4-DNP, respectively. Under the optimized experimental conditions, Beer's law is obeyed over the concentration ranges of 1.25–15.0 and 2.0–18.0 μg mL−1 GBP for PA and 2,4-DNP methods, respectively. The molar absorptivity, Sandell's sensitivity, detection and, quantification limits for both methods are also reported. The proposed methods were applied successfully to the determination of GBP in pure form and commercial capsules. Statistical comparison of the results was performed using Student's t-test and F-ratio at 95% confidence level, and there was no significant difference between the reference and proposed methods with regard to accuracy and precision. Further, the validity of the proposed methods was confirmed by recovery studies via standard addition technique. PMID:21760787

  10. Diluted thrombin time reliably measures low to intermediate plasma dabigatran concentrations.

    PubMed

    Božič-Mijovski, Mojca; Malmström, Rickard E; Malovrh, Petra; Antovic, Jovan P; Vene, Nina; Šinigoj, Petra; Mavri, Alenka

    2016-07-01

    Direct oral anticoagulant dabigatran was first introduced as a fixed-dose drug without routine coagulation monitoring, but current recommendations suggest that diluted thrombin time can be used to estimate plasma drug level. The aim of this study was to assess a diluted thrombin time assay based on the same thrombin reagent already used for traditional thrombin time measurements that reliably measure low to intermediate plasma dabigatran levels. We included 44 patients with atrial fibrillation who started treatment with dabigatran 150 mg (23 patients) or 110 mg (21 patients) twice a day. Blood samples were collected at baseline (no dabigatran) and 2-4 weeks after the beginning of dabigatran therapy at trough and at peak. Plasma dabigatran levels were measured with diluted thrombin time and compared to liquid chromatography with tandem mass spectrometry as the reference method. The performance of the diluted thrombin time was compared to Hemoclot® Thrombin Inhibitor and Ecarin Chromogenic Assay. In ex vivo plasma samples, diluted thrombin time highly correlated with the liquid chromatography with tandem mass spectrometry (Pearson's R = 0.9799). In the low to intermediate range (dabigatran concentration ≤ 100 µg/L) diluted thrombin time correlated significantly more closely to the liquid chromatography with tandem mass spectrometry (R = 0.964) than Hemoclot® Thrombin Inhibitor (R = 0.935, p = 0.05) or Ecarin Chromogenic Assay (R = 0.915, p < 0.01). It was also the only functional assay without any significant bias in the low to intermediate range. Both trough and peak diluted thrombin time values were similar to liquid chromatography with tandem mass spectrometry. We conclude that the diluted thrombin time assay presented in this study reliably detects dabigatran and that it is superior to the Hemoclot® Thrombin Inhibitor assay in the low to intermediate range. © The Author(s) 2015.

  11. Loss of Nuclear Localized and Tyrosine Phosphorylated Stat5 in Breast Cancer Predicts Poor Clinical Outcome and Increased Risk of Antiestrogen Therapy Failure

    PubMed Central

    Peck, Amy R.; Witkiewicz, Agnieszka K.; Liu, Chengbao; Stringer, Ginger A.; Klimowicz, Alexander C.; Pequignot, Edward; Freydin, Boris; Tran, Thai H.; Yang, Ning; Rosenberg, Anne L.; Hooke, Jeffrey A.; Kovatich, Albert J.; Nevalainen, Marja T.; Shriver, Craig D.; Hyslop, Terry; Sauter, Guido; Rimm, David L.; Magliocco, Anthony M.; Rui, Hallgeir

    2011-01-01

    Purpose To investigate nuclear localized and tyrosine phosphorylated Stat5 (Nuc-pYStat5) as a marker of prognosis in node-negative breast cancer and as a predictor of response to antiestrogen therapy. Patients and Methods Levels of Nuc-pYStat5 were analyzed in five archival cohorts of breast cancer by traditional diaminobenzidine-chromogen immunostaining and pathologist scoring of whole tissue sections or by immunofluorescence and automated quantitative analysis (AQUA) of tissue microarrays. Results Nuc-pYStat5 was an independent prognostic marker as measured by cancer-specific survival (CSS) in patients with node-negative breast cancer who did not receive systemic adjuvant therapy, when adjusted for common pathology parameters in multivariate analyses both by standard chromogen detection with pathologist scoring of whole tissue sections (cohort I; n = 233) and quantitative immunofluorescence of a tissue microarray (cohort II; n = 291). Two distinct monoclonal antibodies gave concordant results. A progression array (cohort III; n = 180) revealed frequent loss of Nuc-pYStat5 in invasive carcinoma compared to normal breast epithelia or ductal carcinoma in situ, and general loss of Nuc-pYStat5 in lymph node metastases. In cohort IV (n = 221), loss of Nuc-pYStat5 was associated with increased risk of antiestrogen therapy failure as measured by univariate CSS and time to recurrence (TTR). More sensitive AQUA quantification of Nuc-pYStat5 in antiestrogen-treated patients (cohort V; n = 97) identified by multivariate analysis patients with low Nuc-pYStat5 at elevated risk for therapy failure (CSS hazard ratio [HR], 21.55; 95% CI, 5.61 to 82.77; P < .001; TTR HR, 7.30; 95% CI, 2.34 to 22.78; P = .001). Conclusion Nuc-pYStat5 is an independent prognostic marker in node-negative breast cancer. If confirmed in prospective studies, Nuc-pYStat5 may become a useful predictive marker of response to adjuvant hormone therapy. PMID:21576635

  12. Analysis of Human Papilloma Virus 16/18 DNA and its Correlation with p16 Expression in Oral Cavity Squamous Cell Carcinoma in North-Eastern India: A Chromogenic in-situ Hybridization Based Study

    PubMed Central

    Jitani, Ankit Kumar; Mishra, Jaya; Shunyu, N. Brian; Khonglah, Yookarin; Medhi, Jayanta

    2015-01-01

    Background The incidence of head and neck squamous cell carcinoma (HNSCC) is quite high in North Eastern India. Apart from the traditional risk factors like tobacco and alcohol consumption, human papilloma virus (HPV) is now considered an established causative agent. These HPV related tumour have a clinico-pathological profile that is quite divergent from conventional non-HPV related tumours. Association of HPV in oral cancers has not been explored in north-east India. Materials and Methods Thirty-one patients with oral cavity squamous cell carcinoma (OSCC) on treatment from October 2010 to January 2013 were included in the study. Patients who received neo-adjuvant chemotherapy were excluded. HPV 16/18 DNA was evaluated using Chromogenic in-situ Hybridization (CISH). Presence of nuclear signals was taken as positive HPV expression. p16 was evaluated using immunohistochemistry and was considered positive if ≥ 80% of the tumour cells showed strong and diffuse nuclear/cytoplasmic immunostaining. The results were analysed using Fisher exact test and confidence interval was calculated where required. Results The study group age ranged from 30 to 80 years (median age- 54.2 years). The most common site was gum, with well differentiated squamous cell carcinoma being the most common histology. HPV 16/18 DNA was positive in 29% (95% CI: 13.03% - 44.97%) cases and had a clear tendency towards statistical significance with non-smoker cases (p=0.05), lymph node metastasis (p=0.05) and a significant correlation with p16 overexpression (p=0.04). There was no significant correlation with other clinico-pathological parameters. Conclusion HPV 16/18 is associated with OSCC, commonly seen among non-smokers and may be related to nodal metastasis. So, HPV may be used as a prognostic factor in OSCC and p16 may be considered as a surrogate marker for HPV. PMID:26435951

  13. Spectrophotometric Determination of Rifampicin in Bulk Drug and Pharmaceutical Formulations Based on Redox and Complexation Reactions

    NASA Astrophysics Data System (ADS)

    Swamy, N.; Basavaiah, K.

    2017-09-01

    Two spectrophotometric methods were developed and validated for the determination of rifampicin (RIF) in bulk form, formulations, and spiked human urine. The first method is based on the reduction of the Folin-Ciocalteu (FC) reagent by RIF to form a blue colored chromogen with λmax at 760 nm (the FCR method). In the second method, iron(III) is reduced by RIF in a neutral medium, and the resulting iron(II) is complexed with ferricyanide to form a Prussian blue peaking at 750 nm (the FFC method). Under optimum conditions, Beer's law enabled the determination of the drug in the concentration ranges 1-35 and 2.5-50 μg/mL with apparent molar absorptivities of 2.72 × 104 and 1.63×104 L/(mol × cm) for the FCR and FFC methods, respectively. The Sandell sensitivity, limits of detection (LOD), and quantification (LOQ) values were also reported for both methods. The precision of the methods, with % RSD of < 2%, was satisfactory, and the accuracy was higher than 2% (RE). The proposed methods were successfully applied to the determination of drug in capsules without interference from common additives and spiked human urine without interference from endogenous substances. A statistical analysis indicated that there was no significant difference between the results obtained by the developed methods and the official method.

  14. Evaluation of Two New Chromogenic Media, CHROMagar MRSA and S. aureus ID, for Identifying Staphylococcus aureus and Screening Methicillin-Resistant S. aureus

    PubMed Central

    Hedin, Göran; Fang, Hong

    2005-01-01

    Thirty-nine methicillin-resistant Staphylococcus aureus (MRSA) isolates with diverse genetic backgrounds and two reference strains were correctly identified as S. aureus on CHROMagar MRSA and S. aureus ID media. Growth inhibition on CHROMagar MRSA was noted. A combination of cefoxitin disk and S. aureus ID was found suitable for rapid MRSA screening. PMID:16081989

  15. Performance of Candida ID, a New Chromogenic Medium for Presumptive Identification of Candida Species, in Comparison to CHROMagar Candida

    PubMed Central

    Willinger, Birgit; Hillowoth, Cornelia; Selitsch, Brigitte; Manafi, Mammad

    2001-01-01

    Candida ID agar allows identification of Candida albicans and differentiation of other Candida species. In comparison with CHROMagar Candida, we evaluated the performance of this medium directly from 596 clinical specimens. In particular, detection of C. albicans after 24 h of incubation was easier on Candida ID (sensitivity, 96.8%) than on CHROMagar (sensitivity, 49.6%). PMID:11574621

  16. Chromogenic agar medium for detection and isolation of Escherichia coli serogroups O26,O45,O103,O111,O121, and O145 from fresh beef and cattle feces

    USDA-ARS?s Scientific Manuscript database

    Non-O157 Shiga toxin–producing Escherichia coli (STEC) strains are clinically important foodborne pathogens. Unlike E. coli O157:H7, these foodborne pathogens have no unique biochemical characteristics to readily distinguish them from other E. coli strains growing on plating media. In this study, a ...

  17. Quantitation of Pyrantel Pamoate in Pharmaceuticals Using Permanganate by Visible Spectrophotometry

    NASA Astrophysics Data System (ADS)

    Rajendraprasad, N.; Basavaiah, K.

    2014-03-01

    Two simple, accurate and precise spectrophotometric methods are developed and validated for the assay of pyrantel pamoate (PP) in pharmaceuticals. The methods employ the oxidative property of potassium permanganate (KMnO4) in acidic and alkaline conditions. In the first method (method A), PP is converted into its free base, pyrantel (PR), and treated with known excess of KMnO4 in acidic condition followed by the measurement of unreacted KMnO4 at 550 nm. Method B is based on the registration of absorbance of green colored chromogen formed due to the reduction of KMnO4 by PP in alkaline condition. The methods obeyed Beer's law over a range of 1-20 μg/ml in inverse manner, and 0.75-15 μg/ml for method A and method B, respectively, with apparent molar absorptivity values of 1.05ṡ104 and 2.85ṡ104 lṡmol-1ṡcm-1. The optical parameters such as limits of detection (LOD), quantification (LOQ), and the Sandell sensitivity values are also reported. The accuracy and precision of the methods are assessed on intra- and inter-day basis. A recovery study by standard addition procedure is also carried out for further assurance of accuracy. The developed methods are successfully applied to determine PP in tablets. The results are more satisfactory as per current ICH guidelines.

  18. Microfluidics for rapid cytokeratin immunohistochemical staining in frozen sections.

    PubMed

    Brajkovic, Saska; Dupouy, Diego G; de Leval, Laurence; Gijs, Martin Am

    2017-08-01

    Frozen sections (FS) of tumor samples represent a cornerstone of pathological intraoperative consultation and have an important role in the microscopic analysis of specimens during surgery. So far, immunohistochemical (IHC) stainings on FS have been demonstrated for a few markers using manual methods. Microfluidic technologies have proven to bring substantial improvement in many fields of diagnostics, though only a few microfluidic devices have been designed to improve the performance of IHC assays. In this work, we show optimization of a complete pan-cytokeratin chromogenic immunostaining protocol on FS using a microfluidic tissue processor into a protocol taking <12 min. Our results showed specificity and low levels of background. The dimensions of the microfluidic prototype device are compatible with the space constraints of an intraoperative pathology laboratory. We therefore anticipate that the adoption of microfluidic technologies in the field of surgical pathology can significantly improve the way FSs influence surgical procedures.

  19. Colorimetric detection of glucose based on gold nanoparticles coupled with silver nanoparticles

    NASA Astrophysics Data System (ADS)

    Gao, Yan; Wu, Yiting; Di, Junwei

    2017-02-01

    We have coupled gold nanoparticles (AuNPs) with silver nanoparticles (AgNPs) to assemble a plasmonic sensing platform for colorimetric detection of glucose. In this system, small AuNPs ( 4 nm) can act as glucose oxidase (GOD) mimic enzyme to catalytically oxidize glucose in the presence of oxygen, producing hydrogen peroxide, which dissolves AgNPs to lead the color changes. Glucose can be detected not only by naked eyes (from yellow to red) but also by spectrophotometer in the concentration range of 5-70 μM, with detection limit of 3 μM. More importantly, we found that L-cysteine added in the system can markedly improve the selectivity for the detection of glucose. The proposed method was used to application for the detection of glucose in human serum with satisfactory results. This system is simple and low cost without using any enzymes and organic chromogenic agents.

  20. Microfluidics for rapid cytokeratin immunohistochemical staining in frozen sections

    PubMed Central

    Brajkovic, Saska; Dupouy, Diego G.; de Leval, Laurence; Gijs, Martin A. M.

    2017-01-01

    Frozen sections (FS) of tumor samples represent a cornerstone of pathological intraoperative consultation and play an important role in the microscopic analysis of specimens during surgery. So far, immunohistochemical (IHC) stainings on FS have been demonstrated for a few markers using manual methods. Microfluidic technologies have proven to bring substantial improvement in many fields of diagnostics, though only a few microfluidic devices have been designed to improve the performance of IHC assays. In this work, we show optimization of a complete pan-cytokeratin chromogenic immunostaining protocol on FS using a microfluidic tissue processor, into a protocol taking less than 12 minutes. Our results showed specificity and low levels of background. The dimensions of the microfluidic prototype device are compatible with the space constraints of an intraoperative pathology laboratory. We therefore anticipate that the adoption of microfluidic technologies in the field of surgical pathology can significantly improve the way FSs influence surgical procedures. PMID:28553936

  1. Image-based computational quantification and visualization of genetic alterations and tumour heterogeneity

    PubMed Central

    Zhong, Qing; Rüschoff, Jan H.; Guo, Tiannan; Gabrani, Maria; Schüffler, Peter J.; Rechsteiner, Markus; Liu, Yansheng; Fuchs, Thomas J.; Rupp, Niels J.; Fankhauser, Christian; Buhmann, Joachim M.; Perner, Sven; Poyet, Cédric; Blattner, Miriam; Soldini, Davide; Moch, Holger; Rubin, Mark A.; Noske, Aurelia; Rüschoff, Josef; Haffner, Michael C.; Jochum, Wolfram; Wild, Peter J.

    2016-01-01

    Recent large-scale genome analyses of human tissue samples have uncovered a high degree of genetic alterations and tumour heterogeneity in most tumour entities, independent of morphological phenotypes and histopathological characteristics. Assessment of genetic copy-number variation (CNV) and tumour heterogeneity by fluorescence in situ hybridization (ISH) provides additional tissue morphology at single-cell resolution, but it is labour intensive with limited throughput and high inter-observer variability. We present an integrative method combining bright-field dual-colour chromogenic and silver ISH assays with an image-based computational workflow (ISHProfiler), for accurate detection of molecular signals, high-throughput evaluation of CNV, expressive visualization of multi-level heterogeneity (cellular, inter- and intra-tumour heterogeneity), and objective quantification of heterogeneous genetic deletions (PTEN) and amplifications (19q12, HER2) in diverse human tumours (prostate, endometrial, ovarian and gastric), using various tissue sizes and different scanners, with unprecedented throughput and reproducibility. PMID:27052161

  2. Image-based computational quantification and visualization of genetic alterations and tumour heterogeneity.

    PubMed

    Zhong, Qing; Rüschoff, Jan H; Guo, Tiannan; Gabrani, Maria; Schüffler, Peter J; Rechsteiner, Markus; Liu, Yansheng; Fuchs, Thomas J; Rupp, Niels J; Fankhauser, Christian; Buhmann, Joachim M; Perner, Sven; Poyet, Cédric; Blattner, Miriam; Soldini, Davide; Moch, Holger; Rubin, Mark A; Noske, Aurelia; Rüschoff, Josef; Haffner, Michael C; Jochum, Wolfram; Wild, Peter J

    2016-04-07

    Recent large-scale genome analyses of human tissue samples have uncovered a high degree of genetic alterations and tumour heterogeneity in most tumour entities, independent of morphological phenotypes and histopathological characteristics. Assessment of genetic copy-number variation (CNV) and tumour heterogeneity by fluorescence in situ hybridization (ISH) provides additional tissue morphology at single-cell resolution, but it is labour intensive with limited throughput and high inter-observer variability. We present an integrative method combining bright-field dual-colour chromogenic and silver ISH assays with an image-based computational workflow (ISHProfiler), for accurate detection of molecular signals, high-throughput evaluation of CNV, expressive visualization of multi-level heterogeneity (cellular, inter- and intra-tumour heterogeneity), and objective quantification of heterogeneous genetic deletions (PTEN) and amplifications (19q12, HER2) in diverse human tumours (prostate, endometrial, ovarian and gastric), using various tissue sizes and different scanners, with unprecedented throughput and reproducibility.

  3. Intestinal Carriage of Carbapenemase-Producing Organisms: Current Status of Surveillance Methods

    PubMed Central

    Jacobs, Michael R.; Wilson, Brigid; Kaye, Keith; Donskey, Curtis J.; Perez, Federico

    2015-01-01

    SUMMARY Carbapenemases have become a significant mechanism for broad-spectrum β-lactam resistance in Enterobacteriaceae and other Gram-negative bacteria such as Pseudomonas and Acinetobacter spp. Intestinal carriage of carbapenemase-producing organisms (CPOs) is an important source of transmission. Isolation of carriers is one strategy that can be used to limit the spread of these bacteria. In this review, we critically examine the clinical performance, advantages, and disadvantages of methods available for the detection of intestinal carriage of CPOs. Culture-based methods (Centers for Disease Control and Prevention [CDC] protocols, chromogenic media, specialized agars, and double-disk synergy tests) for detecting carriage of CPOs are convenient due to their ready availability and low cost, but their limited sensitivity and long turnaround time may not always be optimal for infection control practices. Contemporary nucleic acid amplification techniques (NAATs) such as real-time PCR, hybridization assays, loop-mediated isothermal amplification (LAMP), or a combined culture and NAAT approach may provide fast results and/or added sensitivity and specificity compared with culture-based methods. Infection control practitioners and clinical microbiologists should be aware of the strengths and limitations of available methods to determine the most suitable approach for their medical facility to fit their infection control needs. PMID:26511484

  4. [Depyrogenation test regarding inox and glass containers in the preparation of parenteral nutrition mixtures].

    PubMed

    Lajoinie, A; Vasselon, P; Tall, M-L; Salmon, D; Bréant, V; Diouf, E; Pivot, C; Pirot, F

    2012-09-01

    The preparation of parenteral nutrition mixture (PNM) in an open chamber requires the use of intermediate containers sterile and non-pyrogenic. A sterilization of containers by moist heat in large autoclaves is the suitable method. However, sterilization by moist heat is not a depyrogenation method. In our study, we report the validation of a sterilization and depyrogenation method for containers by dry heat using a convection oven. Sterilization and depyrogenation of material by dry heat have been audited by the reduction of at least three logarithms of original endotoxin rate. The containers were initially artificially contaminated with a suspension of endotoxin for 16 hours. Contaminated containers were placed in an oven with revolving heat at 250 °C for 1 hour. After treatment with dry heat, the residual endotoxin levels in the containers were determined by a kinetic chromogenic method. After treatment with dry heat, the average log reductions of endotoxin levels were respectively, for glass and steel containers, 4.78 ± 0.07 and 4.87 ± 0.03. The present validation study confirms the effectiveness of treatment with dry heat for sterilization and depyrogenation of glass and steel containers. This method of sterilization and depyrogenation meets the microbiological quality requirements for the preparation of MNP. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  5. Dendrimer enriched single-use aptasensor for impedimetric detection of activated protein C.

    PubMed

    Erdem, Arzum; Congur, Gulsah

    2014-05-01

    A novel impedimetric aptasensor for detection of human activated protein C (APC) was introduced for the first time in the present study. An enhanced sensor response was obtained using poly(amidoamine) (PAMAM) dendrimer having 16 succinamic acid surface groups (generation 2, G2-PS), that was modified onto the surface of screen printed graphite electrode (G2-PS/SPE). An amino modified DNA aptamer was then immobilized onto the surface of G2-PS modified SPE. The selective interaction of APT with its cognate protein, APC was investigated using different electrochemical techniques; differential pulse voltammetry (DPV), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The microscopic characterization was consecutively performed before/after each modification/interaction step using scanning electron microscopy (SEM) and atomic force microscopy (AFM). The selectivity of aptasensor was tested in the presence of numerous proteins; protein C, thrombin, bovine serum albumin, factor Va and chromogenic substrate in different buffer mediums. The APC detection in the artificial serum; fetal bovine serum (FBS) was also performed impedimetrically. This dendrimer modified aptasensor technology brings several advantages: being single-use, fast screening with low-cost per measurement and resulting in sensitive detection of APC with the detection limits of 0.74 μg/mL (0.46 pmol in 35 μL sample) in buffer medium, and 2.03 μg/mL (1.27 pmol in 35 μL sample) in serum. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Application of β-glucuronidase (GusA) as an effective reporter for extremely acidophilic Acidithiobacillus ferrooxidans.

    PubMed

    Wang, Huiyan; Fang, Liangyan; Wen, Qing; Lin, Jianqun; Liu, Xiangmei

    2017-04-01

    Acidithiobacillus ferrooxidans is a model organism for investigating metal sulfide bioleaching. The regulatory mechanism of gene expression by metabolizing various substrates is critical for understanding its role in bioleaching processes. However, no reporter has been successfully employed to study gene expression in A. ferrooxidans to date. In this study, a sensitive and robust reporter system based on β-glucuronidase (GusA) was described for feasible application in A. ferrooxidans. A set of vectors, which contained the transcriptional and translational fusions of gusA, were constructed and employed to analyze promoter activity and efficiency of translation initiation in A. ferrooxidans. Ptac and P2811 were screened out from ten tested promoters and could be used as strong promoters for gene overexpression in A. ferrooxidans. Among the four translational fusions of gusA with different start codons, ATG was most active, followed by TTG and GTG, while CTG showed the least activity. The transcriptional inhibition effect of an IclR-like transcription factor was also observed on its own encoding gene AFE_1668 as well as its neighboring AFE_1667. In addition, the specific chromogenic reaction of GusA could be detected and visualized by colonies of A. ferrooxidans containing gusA expression plasmids. Generally, the established GusA reporter system would be applied not only for quantitative analysis of promoter strength and its transcriptional regulation but also for qualitative colony screening in A. ferrooxidans in the future.

  7. Site-Specific Photoconjugation of Beta-Lactamase Fragments to Monoclonal Antibodies Enables Sensitive Analyte Detection via Split-Enzyme Complementation.

    PubMed

    Yu, Feifan; Alesand, Veronica; Nygren, Per-Åke

    2018-02-27

    Protein fragment complementation assays (PCA) rely on a proximity-driven reconstitution of a split reporter protein activity, typically via interaction between bait and prey units separately fused to the reporter protein halves. The PCA principle can also be formatted for use in immunossays for analyte detection, e.g., via the use of small immunoglobulin binding proteins (IgBp) as fusion partners to split-reporter protein fragments for conversion of pairs of antibodies into split-protein half-probes. However, the non-covalent binding between IgBp and antibodies is not ideal for development of robust assays. Here, the authors describe how split-enzyme reporter halves can be both site-specifically and covalently photoconjugated at antibody Fc-parts for use in homogeneous dual-antibody in vitro immunoassays based on analyte-dependent split-enzyme fragment complementation. The half-probes consist of parts of a beta-lactamase split-protein reporter fused to an immunoglobulin Fc binding domain equipped with a unique cysteine residue at which a photoactivable maleimide benzophenone group (MBP) is attached. Using such antibody conjugates the authors obtain an analyte-driven complementation of the reporter enzyme fragments monitored via conversion of a chromogenic substrate. Results from detection of human interferon-gamma and the extracellular domain of HER2 is shown. The described principles for site-specific conjugation of proteins to antibodies should be broadly applicable. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Chitosan nanoparticles for the linear release of model cationic Peptide.

    PubMed

    Piras, Anna Maria; Sandreschi, Stefania; Maisetta, Giuseppantonio; Esin, Semih; Batoni, Giovanna; Chiellini, Federica

    2015-07-01

    The present study is focused on the development of a model drug delivery system (DDS) based on Chitosan (CS) nanoparticles using Renin substrate I (RSI) as model agent. RSI shares the main chemical-physical features of several biologically active antimicrobial peptides (AMPs). AMPs have a great therapeutic potential that is hampered by their lability in the biological fluids and as such they are perfect candidates for DDS. The development studies of quality DDS loaded with AMPs would require highly sensitive and specific quantification assays. The use of RSI allowed for the fine-tuning and optimization of the formulation parameters to promote the hydrophobic interactions between CS and the cationic peptide, favour the loading of the active ingredient and enhance the release properties of the carrier. RSI was encapsulated in chitosan NPs by mean of ionic gelation and a chromogenic enzymatic essay was carried out for the release kinetics evaluation. The developed formulations displayed almost 100% of encapsulation efficacy, low burst percentages, and a linear release of the model peptide. A release model was created showing a direct dependence on both the amount of RSI and NPs radius. Although CS has always been formulated with negatively charged active agents (e.g. oligonucleotides or anionic proteins), the use of ionotropic gelation in presence of a small cationic active agent promoted the formation of "core-shell" NPs. The described model, with tuneable linear release rates, appears eligible for further exploitation such as the loading of therapeutically active AMPs.

  9. Spectrophotometric determination of some histamine H1-antagonists drugs in their pharmaceutical preparations.

    PubMed

    Hassan, Wafaa S; El-Henawee, Magda M; Gouda, Ayman A

    2008-01-01

    Two rapid, simple and sensitive extractive specrophotometric methods has been developed for the determination of three histamine H1-antagonists drugs, e.g., chlorphenoxamine hydrochloride (CPX), diphenhydramine hydrochloride (DPH) and clemastine (CMT) in bulk and in their pharmaceutical formulations. The first method depend upon the reaction of molybdenum(V) thiocyanate ions (Method A) with the cited drugs to form stable ion-pair complexes which extractable with methylene chloride, the orange red color complex was determined colorimetrically at lambda(max) 470nm. The second method is based on the formation of an ion-association complex with alizarin red S as chromogenic reagents in acidic medium (Method B), which is extracted into chloroform. The complexes have a maximum absorbance at 425 and 426nm for (DPH or CMT) and CPX, respectively. Regression analysis of Beer-Lambert plots showed a good correlation in the concentration ranges of 5.0-40 and 5-70microgmL(-1) for molybdenum(V) thiocyanate (Method A) and alizarin red S (Method B), respectively. For more accurate analysis, Ringbom optimum concentration ranges were calculated. The molar absorptivity, Sandell sensitivity, detection and quantification limits were calculated. Applications of the procedure to the analysis of various pharmaceutical preparations gave reproducible and accurate results. Further, the validity of the procedure was confirmed by applying the standard addition technique and the results obtained in good agreement well with those obtained by the official method.

  10. Spectrophotometric determination of some histamine H1-antagonists drugs in their pharmaceutical preparations

    NASA Astrophysics Data System (ADS)

    Hassan, Wafaa S.; El-Henawee, Magda M.; Gouda, Ayman A.

    2008-01-01

    Two rapid, simple and sensitive extractive specrophotometric methods has been developed for the determination of three histamine H1-antagonists drugs, e.g., chlorphenoxamine hydrochloride (CPX), diphenhydramine hydrochloride (DPH) and clemastine (CMT) in bulk and in their pharmaceutical formulations. The first method depend upon the reaction of molybdenum(V) thiocyanate ions (Method A) with the cited drugs to form stable ion-pair complexes which extractable with methylene chloride, the orange red color complex was determined colorimetrically at λmax 470 nm. The second method is based on the formation of an ion-association complex with alizarin red S as chromogenic reagents in acidic medium (Method B), which is extracted into chloroform. The complexes have a maximum absorbance at 425 and 426 nm for (DPH or CMT) and CPX, respectively. Regression analysis of Beer-Lambert plots showed a good correlation in the concentration ranges of 5.0-40 and 5-70 μg mL -1 for molybdenum(V) thiocyanate (Method A) and alizarin red S (Method B), respectively. For more accurate analysis, Ringbom optimum concentration ranges were calculated. The molar absorptivity, Sandell sensitivity, detection and quantification limits were calculated. Applications of the procedure to the analysis of various pharmaceutical preparations gave reproducible and accurate results. Further, the validity of the procedure was confirmed by applying the standard addition technique and the results obtained in good agreement well with those obtained by the official method.

  11. Evaluation of a New Selective Medium, BD BBL CHROMagar MRSA II, for Detection of Methicillin-Resistant Staphylococcus aureus in Stool Specimens ▿

    PubMed Central

    Havill, Nancy L.; Boyce, John M.

    2010-01-01

    We compared the recovery of methicillin-resistant Staphylococcus aureus (MRSA) on a new selective chromogenic agar, BD BBL CHROMagar MRSA II (CMRSAII), to that on traditional culture media with 293 stool specimens. The recovery of MRSA was greater on the CMRSAII agar. Screening of stool samples can identify patients who were previously unknown carriers of MRSA. PMID:20392908

  12. Squarylium-based chromogenic anion sensors

    NASA Astrophysics Data System (ADS)

    Lee, Eun-Mi; Gwon, Seon-Yeong; Son, Young-A.; Kim, Sung-Hoon

    2012-09-01

    A squarylium (SQ) dye was synthesized by the reaction between squaric acid and 2,3,3-trimethylindolenine and its anion sensing properties were investigated using absorption and emission spectroscopy. This chemosensor exhibited high selectivity for CN- as compared with F-, CHCO2-, Br-, HPO4-, Cl-, and NO3- in acetonitrile, which was attributed to the formation of a 1:1 squarylium:CN- coordination complex, the formation of which was supported by the calculated geometry of the complex.

  13. Comparative study between chemical and atmospheric pressure plasma jet cleaning on glass substrate

    NASA Astrophysics Data System (ADS)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Fhong, Soon Chin; Sahdan, Mohd Zainizan; Nayan, Nafarizal

    2017-01-01

    The atmospheric pressure plasma jet with low frequency and argon as working gas is presented in this paper to demonstrate its application for glass substrate clean and modification. The glass substrate clean by atmospheric pressure plasma jet is an efficient method to replace other substrate clean method. A comparative analysis is done in this paper between substrate cleaned by chemical and plasma treatment methods. Water contact angle reading is taken for a different method of substrate clean and period of treatment. Under the plasma treatment, the sample shows low surface adhesion due to having the surface property of super hydrophilic surface 7.26°. This comparative analysis is necessary in the industrial application for cost production due to sufficient time and method of substrate clean.

  14. Multiplex Staining by Sequential Immunostaining and Antibody Removal on Routine Tissue Sections.

    PubMed

    Bolognesi, Maddalena Maria; Manzoni, Marco; Scalia, Carla Rossana; Zannella, Stefano; Bosisio, Francesca Maria; Faretta, Mario; Cattoretti, Giorgio

    2017-08-01

    Multiplexing, labeling for multiple immunostains in the very same cell or tissue section in situ, has raised considerable interest. The methods proposed include the use of labeled primary antibodies, spectral separation of fluorochromes, bleaching of the fluorophores or chromogens, blocking of previous antibody layers, all in various combinations. The major obstacles to the diffusion of this technique are high costs in custom antibodies and instruments, low throughput, and scarcity of specialized skills or facilities. We have validated a method based on common primary and secondary antibodies and diffusely available fluorescent image scanners. It entails rounds of four-color indirect immunofluorescence, image acquisition, and removal (stripping) of the antibodies, before another stain is applied. The images are digitally registered and the autofluorescence is subtracted. Removal of antibodies is accomplished by disulfide cleavage and a detergent or by a chaotropic salt treatment, this latter followed by antigen refolding. More than 30 different antibody stains can be applied to one single section from routinely fixed and embedded tissue. This method requires a modest investment in hardware and materials and uses freeware image analysis software. Multiplexing on routine tissue sections is a high throughput tool for in situ characterization of neoplastic, reactive, inflammatory, and normal cells.

  15. The epidemiology of Candida species associated with vulvovaginal candidiasis in an Iranian patient population.

    PubMed

    Mahmoudi Rad, M; Zafarghandi, S; Abbasabadi, B; Tavallaee, M

    2011-04-01

    Vulvovaginal candidiasis is a common infection among women worldwide. According to previous epidemiological studies, Candida albicans is the most common species of Candida. The prevalence of non-Candida species, however, is increasing. Identification of Candida species among the population will not only help health professionals to choose suitable antifungal treatments, but also prevent development of drug resistance. The aim of this study was to identify, using chromogenic agar medium, the Candida species associated with vulvovaginal candidiasis among a sample of the Iranian population. In a prospective cohort study during a two year period from March 2006 to March 2008, swab samples of vaginal discharge/secretion were taken from 200 patients admitted to the gynecology clinic of Mahdieh Hospital (Tehran, Iran) with a clinical presentation suggestive of vulvovaginal candidiasis. The isolates obtained were cultured on Sabouraud dextrose agar and chromogenic agar medium. Candida species were also identified by germ tube formation in serum, chlamydospore production on Corn Meal Agar and carbohydrate absorption using the API 20C-AUX kit. Participants were asked to complete a questionnaire investigating the risk factors associated with candidiasis. An assessment of the different species of recurrent and non-recurrent candidiasis was also made. Descriptive statistics, chi-square test, and t-test were used to analyze the data. A total of 191 isolates were obtained from 175 vaginal specimens. Candida albicans accounted for 67% of the strains including single and mixed infections. The other identified species were Candida glabrata (18.3%), Candida tropicalis (6.8%), Candida krusei (5.8%), Candida parapsilosis (1.6%), and Candida guilliermondii (0.5%) respectively. Mixed infection with two or more species of Candida was seen in 10.3% of patients. The most common mixed cause was the combination of Candida albicans and Candida glabrata. Participants who were sexually active and those who had orogenital sex were more likely to suffer recurrent vulvovaginal candidiasis. Candida albicans was the most common cause of recurrent and non-recurrent vulvovaginitis. The second most common species was Candida glabrata. This study suggests CHROMagar method as a convenient and cost effective yet reliable method to isolate the species of Candida especially in cases where more than one species is present. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  16. Monosaccharide composition of acidic gum exudates from Indian Acacia tortilis ssp. raddiana (Savi) Brenan.

    PubMed

    Lakhera, Ajeet Kumar; Kumar, Vineet

    2017-01-01

    Acacia tortilis ssp. raddiana (Savi) Brenan commonly known as Israeli Babool has contributed immensely for sand dunes management in Indian desert leading to wind erosion control and increased biological productivity. The species is extensively used in traditional medicine system for a number of therapeutic applications and as nutraceutical. The polysaccharide was isolated in 43.6% yield from gum exudates. The monosaccharides, L-arabinose, D-galactose D-glucose, L-rhamnose and D-mannose were determined in molar ratio of 78.1%, 18.64%, 0.60%, 1.71% and 0.74% respectively. The molar ratio of uronic acids was studied using diverse spectrophotometric methods and compared with GLC. The content of D-galacturonic acid and D-glucuronic was determined as 3.88% and 4.35% respectively by GLC. The results were compared with the spectrophotometric methods. The results using DMP as chromogenic reagent are closer to that obtained by GLC. Structural analysis of the polysaccharide may provide scientific basis for nutraceutical, pharmaceutical and biological applications of gum exudates from A. tortilis, which is extensively planted in India. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Patterned substrates and methods for nerve regeneration

    DOEpatents

    Mallapragada, Surya K.; Heath, Carole; Shanks, Howard; Miller, Cheryl A.; Jeftinija, Srdija

    2004-01-13

    Micropatterned substrates and methods for fabrication of artificial nerve regeneration conduits and methods for regenerating nerves are provided. Guidance compounds or cells are seeded in grooves formed on the patterned substrate. The substrates may also be provided with electrodes to provide electrical guidance cues to the regenerating nerve. The micropatterned substrates give physical, chemical, cellular and/or electrical guidance cues to promote nerve regeneration at the cellular level.

  18. Cross-sectional study to identify staphylococcal species isolated from teat and inguinal skin of different-aged dairy heifers.

    PubMed

    Adkins, P R F; Dufour, S; Spain, J N; Calcutt, M J; Reilly, T J; Stewart, G C; Middleton, J R

    2018-04-01

    The purpose of this study was to describe the prevalence and distribution of staphylococcal species on the teat and inguinal skin of dairy heifers across the various stages of the heifer life cycle. The cross-sectional study included 106 Holstein heifers with an age range of 0 d to 27 mo that were selected from 11 different groups, based on housing type and age, on a single dairy operation. A composite swabbing sample including all 4 teats and a second composite sample including both inguinal regions of each heifer were collected using gas-sterilized electrostatic dusters (Swiffers; Procter and Gamble, Cincinnati, OH). Swabbing samples were mixed with 10 mL of sterile saline, agitated, and cultured on mannitol salt agar plates. At 24 h, plates were read and up to 10 staphylococcal colonies were saved for further analysis. Staphylococcal isolates were speciated using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or PCR amplification and partial sequencing of rpoB or tuf. The prevalence of staphylococci was compared between the inguinal and teat regions using the chi-squared or Fisher's exact test, as applicable. Logistic regression models were used to investigate the relationship between a heifer's age (treated as a quantitative continuous variable) and the probability of isolating a given staphylococcal species from a given body site (inguinal region or teats). Overall, the most common species identified were Staphylococcus haemolyticus followed by Staphylococcus chromogenes, Staphylococcus xylosus, Staphylococcus devriesei, and Staphylococcus sciuri. Staphylococcus aureus was more prevalent on the teat than in the inguinal region, whereas Staphylococcus arlettae was more prevalent in the inguinal region than on the teat. All other staphylococcal species were as likely to be found on the teat skin as the inguinal region skin. Isolation from the inguinal and teat skin was associated with age for Staphylococcus agnetis, S. chromogenes, S. devriesei, Staphylococcus equorum, S. haemolyticus, Staphylococcus lentus, S. sciuri, Staphylococcus vitulinus, and S. xylosus. The probability of finding S. chromogenes and S. agnetis on the teat and inguinal region increased with age, whereas the probability of S. devriesei and S. haemolyticus decreased with age. This study provides further insight into the ecology of staphylococcal species involved in heifer mastitis. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Separating semiconductor devices from substrate by etching graded composition release layer disposed between semiconductor devices and substrate including forming protuberances that reduce stiction

    DOEpatents

    Tauke-Pedretti, Anna; Nielson, Gregory N; Cederberg, Jeffrey G; Cruz-Campa, Jose Luis

    2015-05-12

    A method includes etching a release layer that is coupled between a plurality of semiconductor devices and a substrate with an etch. The etching includes etching the release layer between the semiconductor devices and the substrate until the semiconductor devices are at least substantially released from the substrate. The etching also includes etching a protuberance in the release layer between each of the semiconductor devices and the substrate. The etch is stopped while the protuberances remain between each of the semiconductor devices and the substrate. The method also includes separating the semiconductor devices from the substrate. Other methods and apparatus are also disclosed.

  20. ACVP-14: Next-Generation Multiplex vRNA and vDNA Lineage Specific In Situ Hybridization Detection With Immunohisto-Fluorescence or Chromogen in the Same Tissue Section with Quantitative Image Analysis in Fixed Tissues from Virally Infected Specimens | Frederick National Laboratory for Cancer Research

    Cancer.gov

    The Tissue Analysis Core within the AIDS and Cancer Virus Program will process, embed and perform microtomy on fixed tissue samples presented in ethanol. HIV/SIVin situhybridization for detection of vRNA and vDNA will be performed using the next-gene

  1. Comparison of two rapid biochemical tests and four chromogenic selective media for detection of carbapenemase-producing Gram-negative bacteria.

    PubMed

    Hinić, Vladimira; Amrein, Ivo; Stammler, Sabrina; Heckendorn, Judith; Meinel, Dominik; Frei, Reno; Egli, Adrian

    2017-04-01

    We evaluated RAPIDEC® CARBA NP, Neo-Rapid CARB, chromID® CARBA SMART (CARB/OXA), Brilliance™ CRE/ESBL, ChromArt CRE and BBL™ CHROMagar™ CPE for the detection of carbapenemase-producing bacteria. The analytical sensitivity of RAPIDEC® CARBA NP was better than that of Neo-Rapid CARB. A combination of carbapenemase and ESBL screening plates could be advantageous. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Vapour-induced solid-state C-H bond activation for the clean synthesis of an organopalladium biothiol sensor.

    PubMed

    Monas, Andrea; Užarević, Krunoslav; Halasz, Ivan; Kulcsár, Marina Juribašić; Ćurić, Manda

    2016-10-27

    Room-temperature accelerated aging in the solid state has been applied for atom- and energy-efficient activation of either one or two C-H bonds of azobenzene and methyl orange by palladium(ii) acetate. Organopalladium complexes are prepared in quantitative reactions without potentially harmful side products. Dicyclopalladated methyl orange is water-soluble and is a selective chromogenic biothiol sensor at physiologically-relevant micromolar concentrations in buffered aqueous media.

  3. Angiofibroma of soft tissue with fibrohistiocytic features and intratumor genetic heterogeneity of NCOA2 gene rearrangement revealed by chromogenic in situ hybridization: a case report.

    PubMed

    Fukuda, Yumiko; Motoi, Toru; Kato, Ikuma; Ikegami, Masachika; Funata, Nobuaki; Ohtomo, Rie; Horiguchi, Shinichiro; Goto, Takahiro; Hishima, Tsunekazu

    2014-05-01

    Angiofibroma of soft tissue is a recently described soft tissue tumor that is characterized by fibroblastic spindle tumor cells with arborizing capillary proliferation. Cytogenetically, it harbors a specific fusion gene involving the nuclear receptor coactivator 2 (NCOA2) gene. We report here additional new pathological and cytogenetic features. A soft tissue tumor in the left thigh of 73-year-old female was investigated. Microscopically, histiocytoid tumor cells were scattered in an edematous background with branching capillary proliferation. Immunohistochemically, we identified that the tumor cells were positive for histiocytic markers such as CD68 and CD163. Rearrangement of the NCOA2 gene was detected successfully by chromogenic in situ hybridization; however, abnormal signal patterns were observed in only a small subset of tumor cells. Unlike typical tumors with bland spindle cells, the present tumor needs to be distinguished from myxoid, dendritic and clear cell tumors. This case may suggest that angiofibroma of soft tissue is not in the center of the fibroblastic/myofibroblastic tumor group, but rather shows a fibrohistiocytic nature. We also found intratumor genetic heterogeneity, which is uncommon for a translocation-associated tumor. Therefore, careful evaluation is required to detect the gene rearrangement in this tumor entity. © 2014 The Authors. Pathology International © 2014 Japanese Society of Pathology and Wiley Publishing Asia Pty Ltd.

  4. Commensal coagulase-negative Staphylococcus from the udder of healthy cows inhibits biofilm formation of mastitis-related pathogens.

    PubMed

    Isaac, Paula; Bohl, Luciana Paola; Breser, María Laura; Orellano, María Soledad; Conesa, Agustín; Ferrero, Marcela Alejandra; Porporatto, Carina

    2017-08-01

    Bovine mastitis, considered the most important cause of economic losses in the dairy industry, is a major concern in veterinary medicine. Staphylococcus aureus and coagulase-negative staphylococci (CNS) are the main pathogens associated with intramammary infections, and bacterial biofilms are suspected to be responsible for the persistence of this disease. CNS from the udder are not necessarily associated with intramammary infections. In fact, some commensal CNS have been shown to have biological activities. This issue led us to screen exoproducts from commensal Staphylococcus chromogenes for anti-biofilm activity against different mastitis pathogens. The cell-free supernatant from S. chromogenes LN1 (LN1-CFS) was confirmed to display a non-biocidal inhibition of pathogenic biofilms. The supernatant was subjected to various treatments to estimate the nature of the biofilm-inhibiting compounds. The results showed that the bioactive compound >5KDa in mass is sensitive to thermal treatment and proteinase K digestion, suggesting its protein properties. LN1-CFS was able to significantly inhibit S. aureus and CNS biofilm formation in a dose-independent manner and without affecting the viability of bovine cells. These findings reveal a new activity of the udder microflora of healthy animals. Studies are underway to purify and identify the anti-biofilm biocompound and to evaluate its biological activity in vivo. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Comparison of Six Chromogenic Agar Media for the Isolation of a Broad Variety of Non-O157 Shigatoxin-Producing Escherichia coli (STEC) Serogroups

    PubMed Central

    Verhaegen, Bavo; De Reu, Koen; Heyndrickx, Marc; De Zutter, Lieven

    2015-01-01

    The isolation of non-O157 STEC from food samples has proved to be challenging. The selection of a suitable selective isolation agar remains problematic. The purpose of this study was to qualitatively and quantitatively evaluate six chromogenic agar media for the isolation of STEC: Tryptone Bile X-glucuronide agar (TBX), Rainbow® Agar O157 (RB), Rapid E. coli O157:H7 (RE), Modified MacConkey Agar (mMac), CHROMagarTM STEC (Chr ST) and chromIDTM EHEC (Chr ID). During this study, 45 E. coli strains were used, including 39 STEC strains belonging to 16 different O serogroups and 6 non-STEC E. coli. All E. coli strains were able to grow on TBX and RB, whereas one STEC strain was unable to grow on Chr ID and a number of other STEC strains did not grow on mMac, CHROMagar STEC and Rapid E. coli O157:H7. However, only the latter three agars were selective enough to completely inhibit the growth of the non-STEC E. coli. Our conclusion was that paired use of a more selective agar such as CHROMagar STEC together with a less selective agar like TBX or Chr ID might be the best solution for isolating non-O157 STEC from food. PMID:26090610

  6. Study on the blood compatibility and biodegradation properties of magnesium alloys.

    PubMed

    Mochizuki, Akira; Kaneda, Hideki

    2015-02-01

    Lately, several magnesium alloys have been investigated as a new class of biomaterials owing to their excellent biodegradability in living tissues. In this study, we considered AZ series of Mg alloy containing aluminum (3% to 9%) and zinc (1%) as a model magnesium alloy, and investigated their biodegradation in whole blood and blood compatibility in vitro. The results of the elution property of metal ions determined using chromogenic assay and the associated pH change show that the degradation resistance of the AZ series alloys in blood is improved by alloying aluminum. Furthermore, the blood compatibility of the alloys was investigated in terms of their hemolysis, factor Xa-like activity, using spectrophotometry and chromogenic assay, respectively, and coagulation time measurements (prothrombin time and activated partial thromboplastin time). The results indicated that the blood compatibility of the AZ series alloys is excellent, irrespective of the alloy composition. The excellent blood compatibility with the coagulation system could be attributed to the eluted Mg(2+) ion, which suppresses the activation of certain coagulation factors in the intrinsic and/or extrinsic coagulation pathways. In terms of the degradation resistance of the AZ series alloys in blood, the results of pH change in blood and the amount of the eluted metal ions indicate that the performance is markedly improved with an increase in aluminum content. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Comparison of Six Chromogenic Agar Media for the Isolation of a Broad Variety of Non-O157 Shigatoxin-Producing Escherichia coli (STEC) Serogroups.

    PubMed

    Verhaegen, Bavo; De Reu, Koen; Heyndrickx, Marc; De Zutter, Lieven

    2015-06-17

    The isolation of non-O157 STEC from food samples has proved to be challenging. The selection of a suitable selective isolation agar remains problematic. The purpose of this study was to qualitatively and quantitatively evaluate six chromogenic agar media for the isolation of STEC: Tryptone Bile X-glucuronide agar (TBX), Rainbow® Agar O157 (RB), Rapid E. coli O157:H7 (RE), Modified MacConkey Agar (mMac), CHROMagarTM STEC (Chr ST) and chromIDTM EHEC (Chr ID). During this study, 45 E. coli strains were used, including 39 STEC strains belonging to 16 different O serogroups and 6 non-STEC E. coli. All E. coli strains were able to grow on TBX and RB, whereas one STEC strain was unable to grow on Chr ID and a number of other STEC strains did not grow on mMac, CHROMagar STEC and Rapid E. coli O157:H7. However, only the latter three agars were selective enough to completely inhibit the growth of the non-STEC E. coli. Our conclusion was that paired use of a more selective agar such as CHROMagar STEC together with a less selective agar like TBX or Chr ID might be the best solution for isolating non-O157 STEC from food.

  8. Endotoxin Detection in Pharmaceuticals and Medical Devices with Kinetic-QCL, a Kinetic-Quantitative Chromogenic Limulus Amebocyte Lysate Assay.

    PubMed

    Berzofsky, Ronald N.

    1995-01-01

    The observation that endotoxin caused gelation in extracts of Limulus amebocytes has been expanded to the development of an in vitro kinetic, quantitative chromogenic LAL assay (Kinetic-QCL) for the detection of endotoxin in aqueous fluids. Within the last 15 years, the use of Limulus amebocyte lysate to detect and control the presence of pyrogenic substances in pharmaceuticals and medical devices has gained wide international acceptance. Both the United States and European Pharmacopoeias contain descriptions of and requirements for the LAL Bacterial Endotoxin Test. Both pharmacopoeias have begun to remove the rabbit pyrogen test requirement in a majority of drug monographs and have substituted endotoxin limits to be determined by LAL. The use of LAL has proved invaluable in controlling the level of endotoxin in finished product. The endotoxin contribution of raw materials and packaging material can be monitored as well. In-process testing at critical production steps can identify additional sources of endotoxin contamination, and depyrogenation processes can be validated by quantitating the degradation of endotoxin challenges. The speed, reproducibility, sensitivity, and economics of the Kinetic-QCL assay, in conjunction with the ppropriate equipment and software, over both the in vivo rabbit pyrogen test and the more traditional LAL gel-clot assay allow a more in-depth approach to the control of endotoxin in pharmaceuticals and medical devices.

  9. Comparison and Recovery of Escherichia coli and Thermotolerant Coliforms in Water with a Chromogenic Medium Incubated at 41 and 44.5°C

    PubMed Central

    Alonso, Jose L.; Soriano, Adela; Carbajo, Oscar; Amoros, Inmaculada; Garelick, Hemda

    1999-01-01

    This study compared the performance of a commercial chromogenic medium, CHROMagarECC (CECC), and CECC supplemented with sodium pyruvate (CECCP) with the membrane filtration lauryl sulfate-based medium (mLSA) for enumeration of Escherichia coli and non-E. coli thermotolerant coliforms (KEC). To establish that we could recover the maximum KEC and E. coli population, we compared two incubation temperature regimens, 41 and 44.5°C. Statistical analysis by the Fisher test of data did not demonstrate any statistically significant differences (P = 0.05) in the enumeration of E. coli for the different media (CECC and CECCP) and incubation temperatures. Variance analysis of data performed on KEC counts showed significant differences (P = 0.01) between KEC counts at 41 and 44.5°C on both CECC and CECCP. Analysis of variance demonstrated statistically significant differences (P = 0.05) in the enumeration of total thermotolerant coliforms (TTCs) on CECC and CECCP compared with mLSA. Target colonies were confirmed to be E. coli at a rate of 91.5% and KEC of likely fecal origin at a rate of 77.4% when using CECCP incubated at 41°C. The results of this study showed that CECCP agar incubated at 41°C is efficient for the simultaneous enumeration of E. coli and KEC from river and marine waters. PMID:10427079

  10. Fabricating nanowire devices on diverse substrates by simple transfer-printing methods.

    PubMed

    Lee, Chi Hwan; Kim, Dong Rip; Zheng, Xiaolin

    2010-06-01

    The fabrication of nanowire (NW) devices on diverse substrates is necessary for applications such as flexible electronics, conformable sensors, and transparent solar cells. Although NWs have been fabricated on plastic and glass by lithographic methods, the choice of device substrates is severely limited by the lithographic process temperature and substrate properties. Here we report three new transfer-printing methods for fabricating NW devices on diverse substrates including polydimethylsiloxane, Petri dishes, Kapton tapes, thermal release tapes, and many types of adhesive tapes. These transfer-printing methods rely on the differences in adhesion to transfer NWs, metal films, and devices from weakly adhesive donor substrates to more strongly adhesive receiver substrates. Electrical characterization of fabricated NW devices shows that reliable ohmic contacts are formed between NWs and electrodes. Moreover, we demonstrated that Si NW devices fabricated by the transfer-printing methods are robust piezoresistive stress sensors and temperature sensors with reliable performance.

  11. Comparison of preprocessing methods and storage times for touch DNA samples

    PubMed Central

    Dong, Hui; Wang, Jing; Zhang, Tao; Ge, Jian-ye; Dong, Ying-qiang; Sun, Qi-fan; Liu, Chao; Li, Cai-xia

    2017-01-01

    Aim To select appropriate preprocessing methods for different substrates by comparing the effects of four different preprocessing methods on touch DNA samples and to determine the effect of various storage times on the results of touch DNA sample analysis. Method Hand touch DNA samples were used to investigate the detection and inspection results of DNA on different substrates. Four preprocessing methods, including the direct cutting method, stubbing procedure, double swab technique, and vacuum cleaner method, were used in this study. DNA was extracted from mock samples with four different preprocessing methods. The best preprocess protocol determined from the study was further used to compare performance after various storage times. DNA extracted from all samples was quantified and amplified using standard procedures. Results The amounts of DNA and the number of alleles detected on the porous substrates were greater than those on the non-porous substrates. The performances of the four preprocessing methods varied with different substrates. The direct cutting method displayed advantages for porous substrates, and the vacuum cleaner method was advantageous for non-porous substrates. No significant degradation trend was observed as the storage times increased. Conclusion Different substrates require the use of different preprocessing method in order to obtain the highest DNA amount and allele number from touch DNA samples. This study provides a theoretical basis for explorations of touch DNA samples and may be used as a reference when dealing with touch DNA samples in case work. PMID:28252870

  12. Wafer bonded virtual substrate and method for forming the same

    DOEpatents

    Atwater, Jr., Harry A.; Zahler, James M [Pasadena, CA; Morral, Anna Fontcuberta i [Paris, FR

    2007-07-03

    A method of forming a virtual substrate comprised of an optoelectronic device substrate and handle substrate comprises the steps of initiating bonding of the device substrate to the handle substrate, improving or increasing the mechanical strength of the device and handle substrates, and thinning the device substrate to leave a single-crystal film on the virtual substrate such as by exfoliation of a device film from the device substrate. The handle substrate is typically Si or other inexpensive common substrate material, while the optoelectronic device substrate is formed of more expensive and specialized electro-optic material. Using the methodology of the invention a wide variety of thin film electro-optic materials of high quality can be bonded to inexpensive substrates which serve as the mechanical support for an optoelectronic device layer fabricated in the thin film electro-optic material.

  13. Wafer bonded virtual substrate and method for forming the same

    NASA Technical Reports Server (NTRS)

    Atwater, Jr., Harry A. (Inventor); Zahler, James M. (Inventor); Morral, Anna Fontcuberta i (Inventor)

    2007-01-01

    A method of forming a virtual substrate comprised of an optoelectronic device substrate and handle substrate comprises the steps of initiating bonding of the device substrate to the handle substrate, improving or increasing the mechanical strength of the device and handle substrates, and thinning the device substrate to leave a single-crystal film on the virtual substrate such as by exfoliation of a device film from the device substrate. The handle substrate is typically Si or other inexpensive common substrate material, while the optoelectronic device substrate is formed of more expensive and specialized electro-optic material. Using the methodology of the invention a wide variety of thin film electro-optic materials of high quality can be bonded to inexpensive substrates which serve as the mechanical support for an optoelectronic device layer fabricated in the thin film electro-optic material.

  14. Methods to introduce sub-micrometer, symmetry-breaking surface corrugation to silicon substrates to increase light trapping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Sang Eon; Hoard, Brittany R.; Han, Sang M.

    Provided is a method for fabricating a nanopatterned surface. The method includes forming a mask on a substrate, patterning the substrate to include a plurality of symmetry-breaking surface corrugations, and removing the mask. The mask includes a pattern defined by mask material portions that cover first surface portions of the substrate and a plurality of mask space portions that expose second surface portions of the substrate, wherein the plurality of mask space portions are arranged in a lattice arrangement having a row and column, and the row is not oriented parallel to a [110] direction of the substrate. The patterningmore » the substrate includes anisotropically removing portions of the substrate exposed by the plurality of spaces.« less

  15. Review of Angiotensin-converting Enzyme Inhibitory Assay: Rapid Method in Drug Discovery of Herbal Plants

    PubMed Central

    Ahmad, Islamudin; Yanuar, Arry; Mulia, Kamarza; Mun’im, Abdul

    2017-01-01

    The renin-angiotensin-aldosterone system is a signaling pathway which responsible in the blood pressure regulation. Angiotensin-converting enzyme (ACE) is one of the key elements responsible for the hypertensive mechanism. It converts angiotensin-I to angiotensin-II. The discovery history of the ACE inhibitory activity assay method has been through a long stage for decades and development continues until today. The ACE inhibitory activity has become an effective screening method in the search for new antihypertensive agents from herbal plants. Some of in vitro assay methods were used to examine the activity of ACE inhibitors based on the substrate usage, such as; Cushman and Cheung Method using a substrate hippuryl-histidyl-leucine (HHL), Holmquist method using a substrate furanacryloyl-tripeptide, Elbl and Wagner method using a substrate benzoil-[l-14C] glicyl-L-histidine-L-leucine, Carmel and Yaron method using a substrate o-aminobenzoylglycyl-p-nitrophenylalanilproline, and Lam method using 3-hydroxybutyrylglycyl-glycyl-glycine as substrate. Several different methods to measure the results of enzymatic reactions or separating substrate with products, including spectrophotometric, fluorometric, high-performance liquid chromatography, electrophoresis, and radiochemistry. Application of the test method for screening the ACE inhibitors activity and investigation of active compounds from natural products can be done easily with this method, it is very helpful in research because the results obtained are simple, accurate, and rapid. PMID:28503045

  16. Methods for producing complex films, and films produced thereby

    DOEpatents

    Duty, Chad E.; Bennett, Charlee J. C.; Moon, Ji -Won; Phelps, Tommy J.; Blue, Craig A.; Dai, Quanqin; Hu, Michael Z.; Ivanov, Ilia N.; Jellison, Jr., Gerald E.; Love, Lonnie J.; Ott, Ronald D.; Parish, Chad M.; Walker, Steven

    2015-11-24

    A method for producing a film, the method comprising melting a layer of precursor particles on a substrate until at least a portion of the melted particles are planarized and merged to produce the film. The invention is also directed to a method for producing a photovoltaic film, the method comprising depositing particles having a photovoltaic or other property onto a substrate, and affixing the particles to the substrate, wherein the particles may or may not be subsequently melted. Also described herein are films produced by these methods, methods for producing a patterned film on a substrate, and methods for producing a multilayer structure.

  17. Method and system for evaluating integrity of adherence of a conductor bond to a mating surface of a substrate

    DOEpatents

    Telschow, K.L.; Siu, B.K.

    1996-07-09

    A method of evaluating integrity of adherence of a conductor bond to a substrate includes: (a) impinging a plurality of light sources onto a substrate; (b) detecting optical reflective signatures emanating from the substrate from the impinged light; (c) determining location of a selected conductor bond on the substrate from the detected reflective signatures; (d) determining a target site on the selected conductor bond from the detected reflective signatures; (e) optically imparting an elastic wave at the target site through the selected conductor bond and into the substrate; (f) optically detecting an elastic wave signature emanating from the substrate resulting from the optically imparting step; and (g) determining integrity of adherence of the selected conductor bond to the substrate from the detected elastic wave signature emanating from the substrate. A system is disclosed which is capable of conducting the method. 13 figs.

  18. Method and system for evaluating integrity of adherence of a conductor bond to a mating surface of a substrate

    DOEpatents

    Telschow, Kenneth L.; Siu, Bernard K.

    1996-01-01

    A method of evaluating integrity of adherence of a conductor bond to a substrate includes: a) impinging a plurality of light sources onto a substrate; b) detecting optical reflective signatures emanating from the substrate from the impinged light; c) determining location of a selected conductor bond on the substrate from the detected reflective signatures; d) determining a target site on the selected conductor bond from the detected reflective signatures; e) optically imparting an elastic wave at the target site through the selected conductor bond and into the substrate; f) optically detecting an elastic wave signature emanating from the substrate resulting from the optically imparting step; and g) determining integrity of adherence of the selected conductor bond to the substrate from the detected elastic wave signature emanating from the substrate. A system is disclosed which is capable of conducting the method.

  19. Metallic coatings on silicon substrates, and methods of forming metallic coatings on silicon substrates

    DOEpatents

    Branagan, Daniel J [Idaho Falls, ID; Hyde, Timothy A [Idaho Falls, ID; Fincke, James R [Los Alamos, NM

    2008-03-11

    The invention includes methods of forming a metallic coating on a substrate which contains silicon. A metallic glass layer is formed over a silicon surface of the substrate. The invention includes methods of protecting a silicon substrate. The substrate is provided within a deposition chamber along with a deposition target. Material from the deposition target is deposited over at least a portion of the silicon substrate to form a protective layer or structure which contains metallic glass. The metallic glass comprises iron and one or more of B, Si, P and C. The invention includes structures which have a substrate containing silicon and a metallic layer over the substrate. The metallic layer contains less than or equal to about 2 weight % carbon and has a hardness of at least 9.2 GPa. The metallic layer can have an amorphous microstructure or can be devitrified to have a nanocrystalline microstructure.

  20. Evaluation of substrate noise suppression method to mitigate crosstalk among trough-silicon vias

    NASA Astrophysics Data System (ADS)

    Araga, Yuuki; Kikuchi, Katsuya; Aoyagi, Masahiro

    2018-04-01

    Substrate noise from a single through-silicon via (TSV) and the noise attenuation by a substrate tap and a guard ring are clarified. A CMOS test vehicle is designed, and 6-µm-diameter TSVs are manufactured on a 20-µm-thick silicon substrate by the via-last method. An on-chip waveform-capturing circuitry is embedded in the test vehicle to capture transient waveforms of substrate noise. The embedded waveform-capturing circuitry demonstrates small and local noise propagation. Experimental results show increased substrate noise level induced by TSVs and the effectiveness of the substrate tap and guard ring for mitigating the crosstalk among TSVs. An analytical model to explain substrate noise propagation is developed to validate experimental results. Results obtained using the substrate model with a multilayer mesh shows good consistency with experimental results, indicating that the model can be used for examination of noise suppression methods.

  1. Method For Improving The Oxidation Resistance Of Metal Substrates Coated With Thermal Barrier Coatings

    DOEpatents

    Thompson, Anthony Mark; Gray, Dennis Michael; Jackson, Melvin Robert

    2003-05-13

    A method for providing a protective coating on a metal-based substrate is disclosed. The method involves the application of an aluminum-rich mixture to the substrate to form a discontinuous layer of aluminum-rich particles, followed by the application of a second coating over the discontinuous layer of aluminum-rich particles. Aluminum diffuses from the aluminum-rich layer into the substrate, and into any bond coat layer which is subsequently applied. Related articles are also described. A method for providing a protective coating on a metal-based substrate is disclosed. The method involves the application of an aluminum-rich mixture to the substrate to form a discontinuous layer of aluminum-rich particles, followed by the application of a second coating over the discontinuous layer of aluminum-rich particles. Aluminum diffuses from the aluminum-rich layer into the substrate, and into any bond coat layer which is subsequently applied. Related articles are also described.

  2. Virtual substrate method for nanomaterials characterization

    PubMed Central

    Da, Bo; Liu, Jiangwei; Yamamoto, Mahito; Ueda, Yoshihiro; Watanabe, Kazuyuki; Cuong, Nguyen Thanh; Li, Songlin; Tsukagoshi, Kazuhito; Yoshikawa, Hideki; Iwai, Hideo; Tanuma, Shigeo; Guo, Hongxuan; Gao, Zhaoshun; Sun, Xia; Ding, Zejun

    2017-01-01

    Characterization techniques available for bulk or thin-film solid-state materials have been extended to substrate-supported nanomaterials, but generally non-quantitatively. This is because the nanomaterial signals are inevitably buried in the signals from the underlying substrate in common reflection-configuration techniques. Here, we propose a virtual substrate method, inspired by the four-point probe technique for resistance measurement as well as the chop-nod method in infrared astronomy, to characterize nanomaterials without the influence of underlying substrate signals from four interrelated measurements. By implementing this method in secondary electron (SE) microscopy, a SE spectrum (white electrons) associated with the reflectivity difference between two different substrates can be tracked and controlled. The SE spectrum is used to quantitatively investigate the covering nanomaterial based on subtle changes in the transmission of the nanomaterial with high efficiency rivalling that of conventional core-level electrons. The virtual substrate method represents a benchmark for surface analysis to provide ‘free-standing' information about supported nanomaterials. PMID:28548114

  3. Rich variety of substrates for surface enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Nguyen, Bich Ha; Hieu Nguyen, Van; Nhung Tran, Hong

    2016-09-01

    The efficiency of the application of surface enhanced Raman spectroscopy (SERS) technique to each specified purpose significantly depends on the choice of the SERS substrate with an appropriate structure as well as on its performance. Until the present time a rich variety of SERS substrates was fabricated. They can be classified according to their structures. The present work is a review of main types of SERS substrates for using in the trace analysis application. They can be classified into 4 groups: (1) Substrates using gold nanoparticles (AuNPs) with spherical shape such as colloidal AuNPs, AuNPs fabricated by pulsed laser deposition, by sputtering or by capillary force assembly (CFA), substrates fabricated by electrospinning technique, substrates using metallic nanoparticle arrays fabricated by electron beam lithography combined with CFA method, substrates using silver nanoparticle (AgNP) arrays grain by chemical seeded method, substrates with tunable surface plasmon resonance, substrates based on precies subnanometer plasmonic junctions within AuNP assemblies, substrates fabricated by simultaneously immobilizing both AuNPs and AgNPs on the same glass sides etc. (2) Substrates using nanostructures with non-spherical shapes such as gold nanowire (NW), or highly anisotropic nickel NW together with large area, free-standing carpets, substrates with obviously angular, quasi-vertically aligned cuboid-shaped TiO2 NW arrays decorated with AgNPs, substrates using gold nanoprism monolayer films, substrates using silver nanocube dimmers or monodisperse close-packed gold nanotriangle monolayers. (3) Substrates using multiparticle complex nanostructure such as nanoparticle cluster arrays, gold nanoflowers and nanodendrites. (4) Flexible substrate such as paper-based swab with gold nanorods, adhesive polymer tapes fabricated by inkjet printing method and flexible and adhesive SERS tapes fabricated by decorating AuNPs via the conventional drop-dry method.

  4. Comparative evaluation of a new commercial media, the CHROMAgar™ mSuperCARBA™, for the detection of carbapenemase-producing Enterobacteriaceae.

    PubMed

    Amar, Ma'ayan; Shalom, Ohad; Adler, Amos

    2017-05-01

    A new chromogenic-based medium (mSuperCARBA™) was tested for screening carbapenemase-producing Enterobacteriaceae (CPE). mSuperCARBA™ was more sensitive (83%) in detecting CPE isolates (n=69, including KPC, NDM, OXA-48, VIM, and IMI) compared with CHROMAgar™-KPC (65%) and MacConkey agar with Imipenem (69%) with comparable specificity for non carbapenemase-producing, carbapenem-resistant Enterobacteriaceae (n=29). Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Comparison of 2 chromogenic media for the detection of extended-spectrum β-lactamase producing Enterobacteriaceae stool carriage in nursing home residents.

    PubMed

    Blane, Beth; Brodrick, Hayley J; Gouliouris, Theodore; Ambridge, Kirsty E; Kidney, Angela D; Ludden, Catherine M; Limmathurotsakul, Direk; Török, M Estée; Peacock, Sharon J

    2016-03-01

    ChromID ESBL agar and Brilliance ESBL agar were compared for the isolation of extended-spectrum β-lactamase (ESBL)-producing Enterobacteriaceae from 298 stools. These had comparable sensitivity and selectivity for the 116 positive samples. Pre-enrichment with cefpodoxime and extending incubation to 48 hours after direct plating both significantly increased sensitivity but reduced selectivity of both agars. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Effect of sampling and short isolation methodologies on the recovery of human pathogenic Yersinia enterocolitica from pig tonsils.

    PubMed

    Van Damme, Inge; Berkvens, Dirk; De Zutter, Lieven

    2012-07-01

    The objective of this study was to determine the effect of sampling (swab samples compared to destructive samples) on isolation rates of human pathogenic Yersinia enterocolitica from pig tonsils. Moreover, the relative efficiency of different rapid, routinely applicable isolation methods was evaluated. Therefore, swab and destructive samples from tonsils of 120 pigs at slaughter were analyzed in parallel using direct plating and different enrichment methods. Salmonella-Shigella-desoxycholate-calcium chloride (SSDC) agar, cefsulodin-irgasan-novobiocin (CIN) agar, and Yersinia enterocolitica chromogenic medium (YeCM) were used as selective agar media. For enrichment, irgasan-ticarcillin-potassium chlorate (ITC) broth and peptone-sorbitol-bile (PSB) broth were incubated at 25°C for 48 h. Overall, 55 tonsils (45.8%) were positive for Y. enterocolitica bioserotype 4/O:3. Recovery was significantly higher using the destructive method compared to the swabbing method. Direct plating resulted in 47 and 28 Y. enterocolitica-positive destructive and swab samples, respectively. Alkali treatment of PSB and ITC enrichment broths significantly increased recovery of pathogenic Y. enterocolitica from destructive tonsil samples. The performance of YeCM for qualitative and quantitative isolation of pathogenic Y. enterocolitica from pig tonsils was equal to SSDC and CIN. In conclusion, direct plating and ISO 10273: 2003 with minor modifications are suitable and rapid methods for isolation of pathogenic Y. enterocolitica from destructive tonsil samples.

  7. Comparative evaluation of chromogenic agar CM1046 and mFC agar for detection of E. coli and thermotolerant coliform bacteria from water samples.

    PubMed

    Wohlsen, T D

    2011-08-01

    The equivalence of Oxoid (CM 1046) Brilliance((TM)) E. coli/coliform selective agar to mFC agar, as used in the Australian/New Zealand Standard Method to detect thermotolerant coliforms and Escherichia coli in water samples, was assessed. A total of 244 water samples were analysed in parallel over a 5-month period. Sewage effluent samples (n = 131, sites = 43), freshwater (n = 62, sites = 18) and marine/brackish water samples (n = 51, sites = 23) were analysed. The Wilcoxon matched-pairs signed-ranks test showed a varying degree of statistical difference between the two methods. All matrices had a higher recovery in the trial method. Enterococci faecalis, Aeromonas spp. and Vibrio spp. did not grow on the CM1046 agar, and Pseudomonas aeruginosa and Enterobacter aerogenes were inhibited. The use of CM 1046 for the detection and enumeration of E. coli and thermotolerant coliforms in water samples is a suitable alternative to the AS/NZS Standard Method. The use of CM1046 agar was less labour intensive and time consuming, as no secondary confirmation steps were required. Confirmed results could be reported within 24 h of sample analysis, as compared to 48 h with the reference method. Public health concerns can be addressed in a more efficient manner. © 2011 Unitywater. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  8. Quantitative Photochemical Immobilization of Biomolecules on Planar and Corrugated Substrates: A Versatile Strategy for Creating Functional Biointerfaces

    PubMed Central

    Martin, Teresa A.; Herman, Christine T.; Limpoco, Francis T.; Michael, Madeline C.; Potts, Gregory K.; Bailey, Ryan C.

    2014-01-01

    Methods for the generation of substrates presenting biomolecules in a spatially controlled manner are enabling tools for applications in biosensor systems, microarray technologies, fundamental biological studies and biointerface science. We have implemented a method to create biomolecular patterns by using light to control the direct covalent immobilization of biomolecules onto benzophenone-modified glass substrates. We have generated substrates presenting up to three different biomolecules patterned in sequence, and demonstrate biomolecular photopatterning on corrugated substrates. The chemistry of the underlying monolayer was optimized to incorporate poly(ethylene glycol) to enable adhesive cell adhesion onto patterned extracellular matrix proteins. Substrates were characterized with contact angle goniometry, AFM, and immunofluorescence microscopy. Importantly, radioimmunoassays were performed to quantify the site density of immobilized biomolecules on photopatterned substrates. Retention of function of photopatterned proteins was demonstrated both by native ligand recognition and cell adhesion to photopatterned substrates, revealing that substrates generated with this method are suitable for probing specific cell receptor-ligand interactions. This molecularly general photochemical patterning method is an enabling tool that will allow the creation of substrates presenting both biochemical and topographical variation, which is an important feature of many native biointerfaces. PMID:21793535

  9. Bacteriocins of Non-aureus Staphylococci Isolated from Bovine Milk.

    PubMed

    Carson, Domonique A; Barkema, Herman W; Naushad, Sohail; De Buck, Jeroen

    2017-09-01

    Non- aureus staphylococci (NAS), the bacteria most commonly isolated from the bovine udder, potentially protect the udder against infection by major mastitis pathogens due to bacteriocin production. In this study, we determined the inhibitory capability of 441 bovine NAS isolates (comprising 26 species) against bovine Staphylococcus aureus Furthermore, inhibiting isolates were tested against a human methicillin-resistant S. aureus (MRSA) isolate using a cross-streaking method. We determined the presence of bacteriocin clusters in NAS whole genomes using genome mining tools, BLAST, and comparison of genomes of closely related inhibiting and noninhibiting isolates and determined the genetic organization of any identified bacteriocin biosynthetic gene clusters. Forty isolates from 9 species ( S. capitis , S. chromogenes , S. epidermidis , S. pasteuri , S. saprophyticus , S. sciuri , S. simulans , S. warneri , and S. xylosus ) inhibited growth of S. aureus in vitro , 23 isolates of which, from S. capitis , S. chromogenes , S. epidermidis , S. pasteuri , S. simulans , and S. xylosus , also inhibited MRSA. One hundred five putative bacteriocin gene clusters encompassing 6 different classes (lanthipeptides, sactipeptides, lasso peptides, class IIa, class IIc, and class IId) in 95 whole genomes from 16 species were identified. A total of 25 novel bacteriocin precursors were described. In conclusion, NAS from bovine mammary glands are a source of potential bacteriocins, with >21% being possible producers, representing potential for future characterization and prospective clinical applications. IMPORTANCE Mastitis (particularly infections caused by Staphylococcus aureus ) costs Canadian dairy producers $400 million/year and is the leading cause of antibiotic use on dairy farms. With increasing antibiotic resistance and regulations regarding use, there is impetus to explore bacteriocins (bacterially produced antimicrobial peptides) for treatment and prevention of bacterial infections. We examined the ability of 441 NAS bacteria from Canadian bovine milk samples to inhibit growth of S. aureus in the laboratory. Overall, 9% inhibited growth of S. aureus and 58% of those also inhibited MRSA. In NAS whole-genome sequences, we identified >21% of NAS as having bacteriocin genes. Our study represents a foundation to further explore NAS bacteriocins for clinical use. Copyright © 2017 American Society for Microbiology.

  10. Bacteriocins of Non-aureus Staphylococci Isolated from Bovine Milk

    PubMed Central

    Carson, Domonique A.; Barkema, Herman W.; Naushad, Sohail

    2017-01-01

    ABSTRACT Non-aureus staphylococci (NAS), the bacteria most commonly isolated from the bovine udder, potentially protect the udder against infection by major mastitis pathogens due to bacteriocin production. In this study, we determined the inhibitory capability of 441 bovine NAS isolates (comprising 26 species) against bovine Staphylococcus aureus. Furthermore, inhibiting isolates were tested against a human methicillin-resistant S. aureus (MRSA) isolate using a cross-streaking method. We determined the presence of bacteriocin clusters in NAS whole genomes using genome mining tools, BLAST, and comparison of genomes of closely related inhibiting and noninhibiting isolates and determined the genetic organization of any identified bacteriocin biosynthetic gene clusters. Forty isolates from 9 species (S. capitis, S. chromogenes, S. epidermidis, S. pasteuri, S. saprophyticus, S. sciuri, S. simulans, S. warneri, and S. xylosus) inhibited growth of S. aureus in vitro, 23 isolates of which, from S. capitis, S. chromogenes, S. epidermidis, S. pasteuri, S. simulans, and S. xylosus, also inhibited MRSA. One hundred five putative bacteriocin gene clusters encompassing 6 different classes (lanthipeptides, sactipeptides, lasso peptides, class IIa, class IIc, and class IId) in 95 whole genomes from 16 species were identified. A total of 25 novel bacteriocin precursors were described. In conclusion, NAS from bovine mammary glands are a source of potential bacteriocins, with >21% being possible producers, representing potential for future characterization and prospective clinical applications. IMPORTANCE Mastitis (particularly infections caused by Staphylococcus aureus) costs Canadian dairy producers $400 million/year and is the leading cause of antibiotic use on dairy farms. With increasing antibiotic resistance and regulations regarding use, there is impetus to explore bacteriocins (bacterially produced antimicrobial peptides) for treatment and prevention of bacterial infections. We examined the ability of 441 NAS bacteria from Canadian bovine milk samples to inhibit growth of S. aureus in the laboratory. Overall, 9% inhibited growth of S. aureus and 58% of those also inhibited MRSA. In NAS whole-genome sequences, we identified >21% of NAS as having bacteriocin genes. Our study represents a foundation to further explore NAS bacteriocins for clinical use. PMID:28667105

  11. Fungal Profile of Vulvovaginal Candidiasis in a Tertiary Care Hospital.

    PubMed

    Kalaiarasan, Krishnapriya; Singh, Rakesh; Chaturvedula, Latha

    2017-03-01

    Vulvovaginal Candidiasis (VVC) is a common medical health problem of adult women. It is most commonly caused by Candida albicans . But there is a change in fungal profile. Sabouraud's Dextrose Agar (SDA) is the most common culture medium used where mixed fungal infection may be missed. It can be detected easily by using chromogenic culture medium. To know the fungal profile of vulvovaginal candidiasis using Candida CHROMagar and antifungal susceptibility pattern in patients attending tertiary care hospital. Culture confirmed cases of VVC presented at Department of Obstetrics and Gynaecology of Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India, from July 2015 to December 2015 were included in the cross-sectional study. Two high vaginal swabs were collected and inoculated on SDA and Candida CHROMagar (Hi-Media, Mumbai, India). After overnight incubation the colonies were counted and colour of the colonies were recorded from Candida CHROMagar. Candida spp. were identified by sugar fermentation and assimilation tests and other conventional tests. Antifungal susceptibility tests were performed by the disc diffusion method using fluconazole (25 μg) and voriconazole (1μg) as per the Clinical and Laboratory Standards Institute (CLSI - M44-A2) guidelines. A total of 50 culture confirmed (23.7%) cases were detected from 211 clinically suspected VVC cases. Candida glabrata (45.1%) was the most common isolate, followed by Candida tropicalis (23.5%) , Candida albicans (17.6%) , Candida krusei (9.8%) and Candida parapsilosis (3.9%) . One mixed infection of C. glabrata and C. albicans was identified on Candida CHROMagar. Mixed fungal infection was observed in 2% of positive culture and 0.5% of VVC cases. The antifungal susceptibility testing revealed that 15.7% and 9.8% isolates of Candida spp. were resistant and Susceptible Dose Dependent (S-DD) respectively to fluconazole. The increase resistant against fluconazole was because of increased isolation of C. glabrata strains. All strains of Candida spp. were susceptible to voriconazole. C. glabrata was the most common causative agent of VVC in a tertiary care hospital. Chromogenic culture medium facilitates detection of mixed fungal infection. In vitro susceptibility testing should be used to guide the treatment especially in cases of non- albicans Candidiasis.

  12. [Comparison between rapid detection method of enzyme substrate technique and multiple-tube fermentation technique in water coliform bacteria detection].

    PubMed

    Sun, Zong-ke; Wu, Rong; Ding, Pei; Xue, Jin-Rong

    2006-07-01

    To compare between rapid detection method of enzyme substrate technique and multiple-tube fermentation technique in water coliform bacteria detection. Using inoculated and real water samples to compare the equivalence and false positive rate between two methods. Results demonstrate that enzyme substrate technique shows equivalence with multiple-tube fermentation technique (P = 0.059), false positive rate between the two methods has no statistical difference. It is suggested that enzyme substrate technique can be used as a standard method for water microbiological safety evaluation.

  13. Electrophoretic Deposition on Porous Non-Conductors

    NASA Technical Reports Server (NTRS)

    Compson, Charles; Besra, Laxmidhar; Liu, Meilin

    2007-01-01

    A method of electrophoretic deposition (EPD) on substrates that are porous and electrically non-conductive has been invented. Heretofore, in order to perform an EPD, it has been necessary to either (1) use a substrate material that is inherently electrically conductive or (2) subject a non-conductive substrate to a thermal and/or chemical treatment to render it conductive. In the present method, instead of relying on the electrical conductivity of the substrate, one ensures that the substrate is porous enough that when it is immersed in an EPD bath, the solvent penetrates throughout the thickness, thereby forming quasi-conductive paths through the substrate. By making it unnecessary to use a conductive substrate, this method simplifies the overall EPD process and makes new applications possible. The method is expected to be especially beneficial in enabling deposition of layers of ceramic and/or metal for chemical and electrochemical devices, notably including solid oxide fuel cells.

  14. Method of transferring a thin crystalline semiconductor layer

    DOEpatents

    Nastasi, Michael A [Sante Fe, NM; Shao, Lin [Los Alamos, NM; Theodore, N David [Mesa, AZ

    2006-12-26

    A method for transferring a thin semiconductor layer from one substrate to another substrate involves depositing a thin epitaxial monocrystalline semiconductor layer on a substrate having surface contaminants. An interface that includes the contaminants is formed in between the deposited layer and the substrate. Hydrogen atoms are introduced into the structure and allowed to diffuse to the interface. Afterward, the thin semiconductor layer is bonded to a second substrate and the thin layer is separated away at the interface, which results in transferring the thin epitaxial semiconductor layer from one substrate to the other substrate.

  15. Laminated structures and methods and compositions for producing same

    DOEpatents

    Fumei, Giancarlo J.; Karabedian, James A.

    1977-04-05

    Methods for bonding two substrates, one of which is polymeric, which comprise coating the surface of at least one substrate with an adhesive composition comprising a major component which is an adhesive for the first substrate and a minor disperse phase which is a solution of a polymer in a solvent for the polymeric substrate and contacting the coated surface of the one substrate with the surface of the other substrate, together with adhesive compositions useful for joining such substrates, laminates so formed, and articles comprised of such laminates.

  16. Method of forming fluorine-bearing diamond layer on substrates, including tool substrates

    DOEpatents

    Chang, R. P. H.; Grannen, Kevin J.

    2002-01-01

    A method of forming a fluorine-bearing diamond layer on non-diamond substrates, especially on tool substrates comprising a metal matrix and hard particles, such as tungsten carbide particles, in the metal matrix. The substrate and a fluorine-bearing plasma or other gas are then contacted under temperature and pressure conditions effective to nucleate fluorine-bearing diamond on the substrate. A tool insert substrate is treated prior to the diamond nucleation and growth operation by etching both the metal matrix and the hard particles using suitable etchants.

  17. High resolution printing of charge

    DOEpatents

    Rogers, John; Park, Jang-Ung

    2015-06-16

    Provided are methods of printing a pattern of charge on a substrate surface, such as by electrohydrodynamic (e-jet) printing. The methods relate to providing a nozzle containing a printable fluid, providing a substrate having a substrate surface and generating from the nozzle an ejected printable fluid containing net charge. The ejected printable fluid containing net charge is directed to the substrate surface, wherein the net charge does not substantially degrade and the net charge retained on the substrate surface. Also provided are functional devices made by any of the disclosed methods.

  18. Method for fabricating .sup.99 Mo production targets using low enriched uranium, .sup.99 Mo production targets comprising low enriched uranium

    DOEpatents

    Wiencek, Thomas C.; Matos, James E.; Hofman, Gerard L.

    1997-01-01

    A radioisotope production target and a method for fabricating a radioisotope production target is provided, wherein the target comprises an inner cylinder, a foil of fissionable material circumferentially contacting the outer surface of the inner cylinder, and an outer hollow cylinder adapted to receive the substantially foil-covered inner cylinder and compress tightly against the foil to provide good mechanical contact therewith. The method for fabricating a primary target for the production of fission products comprises preparing a first substrate to receive a foil of fissionable material so as to allow for later removal of the foil from the first substrate, preparing a second substrate to receive the foil so as to allow for later removal of the foil from the second substrate; attaching the first substrate to the second substrate such that the foil is sandwiched between the first substrate and second substrate to prevent foil exposure to ambient atmosphere, and compressing the exposed surfaces of the first and second substrate to assure snug mechanical contact between the foil, the first substrate and the second substrate.

  19. Method for fabricating .sup.99 Mo production targets using low enriched uranium, .sup.99 Mo production targets comprising low enriched uranium

    DOEpatents

    Wiencek, Thomas C [Orland Park, IL; Matos, James E [Oak Park, IL; Hofman, Gerard L [Downers Grove, IL

    2000-12-12

    A radioisotope production target and a method for fabricating a radioisotope production target is provided, wherein the target comprises an inner cylinder, a foil of fissionable material circumferentially contacting the outer surface of the inner cylinder, and an outer hollow cylinder adapted to receive the substantially foil-covered inner cylinder and compress tightly against the foil to provide good mechanical contact therewith. The method for fabricating a primary target for the production of fission products comprises preparing a first substrate to receive a foil of fissionable material so as to allow for later removal of the foil from the first substrate, preparing a second substrate to receive the foil so as to allow for later removal of the foil from the second substrate; attaching the first substrate to the second substrate such that the foil is sandwiched between the first substrate and second substrate to prevent foil exposure to ambient atmosphere, and compressing the exposed surfaces of the first and second substrate to assure snug mechanical contact between the foil, the first substrate and the second substrate.

  20. Purification and characterization of a novel fibrinolytic α chymotrypsin like serine metalloprotease from the edible mushroom, Lyophyllum shimeji.

    PubMed

    Moon, Sung-Min; Kim, Jae-Sung; Kim, Heung-Joong; Choi, Mi Suk; Park, Bo Ram; Kim, Su-Gwan; Ahn, Hoon; Chun, Hong Sung; Shin, Yong Kook; Kim, Jong-Jin; Kim, Do Kyung; Lee, Sook-Young; Seo, Young-Woo; Kim, Yong Hwan; Kim, Chun Sung

    2014-05-01

    A novel fibrinolytic enzyme was purified from Lyophyllum shimeji, a popular edible mushroom in Asia. The enzyme was purified using combination of anion exchange chromatography on a Mono Q 5/5 column and size exclusion gel filtration chromatography on Superdex 200 100/300 column. This purification protocol resulted 80.9-fold purification of the enzyme and a final yield of 5.7%. The molecular weight of the purified enzyme was estimated to be 21 kDa by SDS-PAGE and size exclusion gel filtration. The N-terminal amino acid sequence was found to be ITFQSASP, which is dissimilar from that of known fibrinolytic enzymes. The purified enzyme was a neutral protease with an optimal reaction pH and temperature of 8.0 and 37°C, respectively. Enzymatic activity was inhibited by Cu(2+) and Co(2+). It was also significantly inhibited by PMSF and TPCK. Furthermore, it was found to exhibit a higher specificity for S-7388, a well-known chymotrypsin chromogenic substrate, indicating chymotrypsin like serine metalloprotease. The relative fibrinolytic activity of 5 μg purified enzyme have two fold more activity than 1 unit/ml of plasmin on fibrin plate. Furthermore, purified enzyme preferentially hydrolyzed the Aα-chain followed by the Bβ- and γ-chain of fibrinogen, which is precursor of fibrin. Therefore, these data suggests that the fibrinolytic enzyme derived from edible mushroom, L. shimeji, might be useful for thrombolytic therapy and preventing thrombotic disease. Copyright © 2013 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  1. Ultrahigh-throughput–directed enzyme evolution by absorbance-activated droplet sorting (AADS)

    PubMed Central

    Gielen, Fabrice; Hours, Raphaelle; Emond, Stephane; Fischlechner, Martin; Schell, Ursula

    2016-01-01

    Ultrahigh-throughput screening, in which members of enzyme libraries compartmentalized in water-in-oil emulsion droplets are assayed, has emerged as a powerful format for directed evolution and functional metagenomics but is currently limited to fluorescence readouts. Here we describe a highly efficient microfluidic absorbance-activated droplet sorter (AADS) that extends the range of assays amenable to this approach. Using this module, microdroplets can be sorted based on absorbance readout at rates of up to 300 droplets per second (i.e., >1 million droplets per hour). To validate this device, we implemented a miniaturized coupled assay for NAD+-dependent amino acid dehydrogenases. The detection limit (10 μM in a coupled assay producing a formazan dye) enables accurate kinetic readouts sensitive enough to detect a minimum of 1,300 turnovers per enzyme molecule, expressed in a single cell, and released by lysis within a droplet. Sorting experiments showed that the AADS successfully enriched active variants up to 2,800-fold from an overwhelming majority of inactive ones at ∼100 Hz. To demonstrate the utility of this module for protein engineering, two rounds of directed evolution were performed to improve the activity of phenylalanine dehydrogenase toward its native substrate. Fourteen hits showed increased activity (improved >4.5-fold in lysate; kcat increased >2.7-fold), soluble protein expression levels (up 60%), and thermostability (Tm, 12 °C higher). The AADS module makes the most widely used optical detection format amenable to screens of unprecedented size, paving the way for the implementation of chromogenic assays in droplet microfluidics workflows. PMID:27821774

  2. Outer membrane vesicles shield Moraxella catarrhalis β-lactamase from neutralization by serum IgG.

    PubMed

    Schaar, Viveka; Paulsson, Magnus; Mörgelin, Matthias; Riesbeck, Kristian

    2013-03-01

    The aim of this study was to detect the presence of IgG against Moraxella catarrhalis β-lactamase in healthy adults, and to determine whether outer membrane vesicles (OMVs) could protect the enzyme from inhibition by anti-β-lactamase IgG. Transmission electron microscopy was used to detect the presence of β-lactamase in OMVs. Sera were examined by ELISA for specific IgG directed against recombinant M. catarrhalis β-lactamase in addition to the outer membrane adhesins MID/Hag, UspA1 and A2. Binding of anti-β-lactamase IgG from serum to OMVs was analysed by flow cytometry. The chromogenic substrate nitrocefin was used to quantify β-lactamase enzyme activity. The presence of β-lactamase was determined in OMVs from a 9-year-old child suffering from M. catarrhalis sinusitis. Furthermore, anti-β-lactamase IgG was detected in sera obtained from healthy adults. Out of 40 adult blood donors (aged 18-65 years) tested, 6 (15.0%) carried anti-β-lactamase IgG. No correlation between IgG titres against β-lactamase and the adhesins was found. Flow cytometry analyses revealed that anti-β-lactamase IgG from serum bound to β-lactamase-positive OMVs. By comparing the β-lactamase activity of intact OMV with OMV that were permeabilized with saponin we found that OMVs shielded active β-lactamase from the anti-β-lactamase IgG. Moraxella catarrhalis β-lactamase is found in, or associated with, OMVs, providing clinical relevance for the vesicles in the spread of antibiotic resistance. Furthermore, OMVs protect β-lactamase from specific IgG.

  3. Mutational studies on HslU and its docking mode with HslV.

    PubMed

    Song, H K; Hartmann, C; Ramachandran, R; Bochtler, M; Behrendt, R; Moroder, L; Huber, R

    2000-12-19

    HslVU is an ATP-dependent prokaryotic protease complex. Despite detailed crystal and molecular structure determinations of free HslV and HslU, the mechanism of ATP-dependent peptide and protein hydrolysis remained unclear, mainly because the productive complex of HslV and HslU could not be unambiguously identified from the crystal data. In the crystalline complex, the I domains of HslU interact with HslV. Observations based on electron microscopy data were interpreted in the light of the crystal structure to indicate an alternative mode of association with the intermediate domains away from HslV. By generation and analysis of two dozen HslU mutants, we find that the amidolytic and caseinolytic activities of HslVU are quite robust to mutations on both alternative docking surfaces on HslU. In contrast, HslVU activity against the maltose-binding protein-SulA fusion protein depends on the presence of the I domain and is also sensitive to mutations in the N-terminal and C-terminal domains of HslU. Mutational studies around the hexameric pore of HslU seem to show that it is involved in the recognition/translocation of maltose-binding protein-SulA but not of chromogenic small substrates and casein. ATP-binding site mutations, among other things, confirm the essential role of the "sensor arginine" (R393) and the "arginine finger" (R325) in the ATPase action of HslU and demonstrate an important role for E321. Additionally, we report a better refined structure of the HslVU complex crystallized along with resorufin-labeled casein.

  4. Anticoagulant activity in salivary glands of the insect vector Culicoides variipennis sonorensis by an inhibitor of factor Xa.

    PubMed

    Pérez de León, A A; Valenzuela, J G; Tabachnick, W J

    1998-02-01

    Blood feeding by the insect vector Culicoides variipennis sonorensis involves laceration of superficial host tissues, an injury that would be expected to trigger the coagulation cascade. Accordingly, the salivary glands of C.v. sonorensis were examined for the presence of an antihemostatic that prevents blood coagulation. Assays using salivary gland extracts showed a delay in the recalcification time of plasma devoid of platelets, indicating the presence of anticoagulant activity. Retardation in the formation of a fibrin clot was also observed after the addition of tissue factor to plasma that was preincubated with salivary gland extracts. Similarly, an inhibitory effect by salivary gland extracts was detected in assays that included factors of the intrinsic pathway. Inhibition of the catalytic activity of purified factor Xa toward its chromogenic substrate suggested that it was the target of the salivary anticoagulant of C.v. sonorensis. This was corroborated by the coincidence of anticoagulant and anti-FXa activities obtained by reverse-phase HPLC. The depletion of anti-FXa activity from salivary glands during blood feeding suggests that the FXa inhibitor functions as anticoagulant. Molecular sieving HPLC yielded an apparent molecular mass of 28 kDa for the salivary FXa inhibitor of C.v. sonorensis. Preventing the formation of thrombin through the inhibition of FXa likely facilitates blood feeding by maintaining the pool of blood fluid at the feeding site. The salivary FXa inhibitor of C.v. sonorensis could impair the network of host-defense mechanisms in the skin microenvironment by avoiding blood coagulation at the site of feeding.

  5. Differential catabolic fate of neuromedin N and neurotensin in the canine intestinal mucosa.

    PubMed

    Barelli, H; Mao, Y K; Vincent, B; Daniel, E E; Vincent, J P; Checler, F

    1993-01-01

    We have established the peptidase content of a P2 fraction (enriched in synaptosomes) and plasma membranes prepared from canine intestinal mucosa. Fourteen exo- and endopeptidases were assayed with fluorimetric or chromogenic substrates and identified by means of specific peptidase inhibitors. Post-proline dipeptidyl aminopeptidase IV, aminopeptidase M, and carboxypeptidase A were the most abundant exopeptidases, while aminopeptidases A and B, dipeptidyl aminopeptidase, pyroglutamyl peptide hydrolase I, and carboxypeptidase B displayed little, if any, activity. Endopeptidase 24.11 was the only endopeptidase that was detected in high amount. By contrast, proline endopeptidase exhibited a low activity, while angiotensin-converting enzyme, endopeptidase 24.15, endopeptidase 24.16, and cathepsin B and D-like activities were not detected. The catabolic rates of the two related neuropeptides, neurotensin (NT) and neuromedin N (NN), established that NN was inactivated 16 to 24 times faster than NT by plasma membrane and P2 fractions, respectively. Furthermore, the two peptides underwent qualitatively distinct mechanisms of degradation. A phosphoramidon-sensitive formation of NT(1-10) was detected as the major NT catabolite, indicating that NT was susceptible to an endoproteolytic cleavage elicited by endopeptidase 24.11. By contrast, NN was inactivated by the action of an exopeptidase at its N-terminus, leading to the formation of [des-Lys1]NN. The occurrence of this NN metabolite was prevented by bestatin and actinonin, but not by the aminopeptidase B inhibitor, arphamenine B, indicating that the release of the N-terminal residue of NN was likely due to aminopeptidase M.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Amperometric detection of extended-spectrum β-lactamase activity: application to the characterization of resistant E. coli strains.

    PubMed

    Rochelet, Murielle; Solanas, Sébastien; Betelli, Laetitia; Neuwirth, Catherine; Vienney, Fabienne; Hartmann, Alain

    2015-05-21

    The amperometric detection of extended-spectrum β-lactamase (ESBL) with carbon screen-printed sensors was investigated in the presence of the Nitrocefin, a commercially-available β-lactamase chromogenic cephalosporin substrate. Using an ESBL isolated from a clinical sample, it was shown for the first time that the intensity of a specific anodic pic current (EP = ∼+0.3 V vs. Ag/AgCl) resulting from the catalytic hydrolysis of the β-lactam ring was proportional to the amount of ESBL. The proof-of-principle of a novel susceptibility assay for the rapid and accurate identification of ESBL- producing bacteria was then demonstrated. The detection scheme relied on (i) the culture of the sample in a medium containing the cefotaxime supplemented or not with the clavulanic acid inhibitor to allow the specific determination of ESBL producers (ii) followed by the incubation of the bacteria with the Nitrocefin and (iii) the measurement of the enzyme product by cyclic voltammetry. The amperometric assay was further applied to the characterization of E. coli strains and to the quantification of the ESBL producers. A detection limit of 5 × 10(4) cfu mL(-1) ESBL-producing E. coli was achieved after a 10 min incubation time. In contrast to the approved routine assays, the electrochemical approach, which did not require isolated colonies to be performed, provided quantified results regarding ESBL activity within a few hours. Finally, owing to its cost-effectiveness, portability and simplicity, this test holds great promise for clinical and environmental applications.

  7. Reactive ion etched substrates and methods of making and using

    DOEpatents

    Rucker, Victor C [San Francisco, CA; Shediac, Rene [Oakland, CA; Simmons, Blake A [San Francisco, CA; Havenstrite, Karen L [New York, NY

    2007-08-07

    Disclosed herein are substrates comprising reactive ion etched surfaces and specific binding agents immobilized thereon. The substrates may be used in methods and devices for assaying or isolating analytes in a sample. Also disclosed are methods of making the reactive ion etched surfaces.

  8. [Considerations when using creatinine as a measure of kidney function].

    PubMed

    Drion, I Iefke; Fokkert, M J Marion; Bilo, H J G Henk

    2013-01-01

    Reported serum creatinine concentrations can sometimes vary considerably, even when the renal function does less so or even not. This variation is partly due to true changes in actual serum concentration, and partly due to interferences in the measurement technique, thus not reflecting a true change in concentration. Increased or decreased endogenous creatinine production, ingested creatinine sources through meat eating or certain creatine formulations, and interference by either browning of chromogenic substances in Jaffe measurement techniques or promotors and inhibitors of enzymatic reaction methods do play a role. Reliable serum creatinine measurements are needed for renal function estimating equations. In screening circumstances and daily practice, chronic kidney disease staging is based on these estimated glomerular filtration rate values. Given the possible influences on reported serum creatinine concentrations, it is important for health care workers to remain critical when interpreting outcomes of renal function estimating equations and to not see every reported result based on an equation as a true reflection of renal function.

  9. μ-PADs for detection of chemical warfare agents.

    PubMed

    Pardasani, Deepak; Tak, Vijay; Purohit, Ajay K; Dubey, D K

    2012-12-07

    Conventional methods of detection of chemical warfare agents (CWAs) based on chromogenic reactions are time and solvent intensive. The development of cost, time and solvent effective microfluidic paper based analytical devices (μ-PADs) for the detection of nerve and vesicant agents is described. The detection of analytes was based upon their reactions with rhodamine hydroxamate and para-nitrobenzyl pyridine, producing red and blue colours respectively. Reactions were optimized on the μ-PADs to produce the limits of detection (LODs) as low as 100 μM for sulfur mustard in aqueous samples. Results were quantified with the help of a simple desktop scanner and Photoshop software. Sarin achieved a linear response in the two concentration ranges of 20-100 mM and 100-500 mM, whereas the response of sulfur mustard was found to be linear in the concentration range of 10-75 mM. Results were precise enough to establish the μ-PADs as a valuable tool for security personnel fighting against chemical terrorism.

  10. Portable Multispectral Colorimeter for Metallic Ion Detection and Classification

    PubMed Central

    Jaimes, Ruth F. V. V.; Borysow, Walter; Gomes, Osmar F.; Salcedo, Walter J.

    2017-01-01

    This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using optoelectronic multispectral sensors was fully integrated in the embedded hardware FPGA ( Field Programmable Gate Array) technology and software based on virtual instrumentation (NI LabView®). The system draws on an indicative colorimeter by using the chromogen reagent of 1-(2-pyridylazo)-2-naphthol (PAN). The results obtained with the signal processing and pattern analysis using the method of the linear discriminant analysis, allows excellent results during detection and classification of Pb(II), Cd(II), Zn(II), Cu(II), Fe(III) and Ni(II) ions, with almost the same level of performance as for those obtained from the Ultravioled and visible (UV-VIS) spectrophotometers of high spectral resolution. PMID:28788082

  11. Tiny Grains Give Huge Gains: Nanocrystal–Based Signal Amplification for Biomolecule Detection

    PubMed Central

    Tong, Sheng; Ren, Binbin; Zheng, Zhilan; Shen, Han; Bao, Gang

    2013-01-01

    Nanocrystals, despite their tiny sizes, contain thousands to millions of atoms. Here we show that the large number of atoms packed in each metallic nanocrystal can provide a huge gain in signal amplification for biomolecule detection. We have devised a highly sensitive, linear amplification scheme by integrating the dissolution of bound nanocrystals and metal-induced stoichiometric chromogenesis, and demonstrated that signal amplification is fully defined by the size and atom density of nanocrystals, which can be optimized through well-controlled nanocrystal synthesis. Further, the rich library of chromogenic reactions allows implementation of this scheme in various assay formats, as demonstrated by the iron oxide nanoparticle linked immunosorbent assay (ILISA) and blotting assay developed in this study. Our results indicate that, owing to the inherent simplicity, high sensitivity and repeatability, the nanocrystal based amplification scheme can significantly improve biomolecule quantification in both laboratory research and clinical diagnostics. This novel method adds a new dimension to current nanoparticle-based bioassays. PMID:23659350

  12. Evaluation of heterotrophic plate and chromogenic agar colony counting in water quality laboratories.

    PubMed

    Hallas, Gary; Monis, Paul

    2015-01-01

    The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers.

  13. Selective and sensitive optical chemosensor for detection of Ag(I) ions based on 2(4-hydroxy pent-3-en-2-ylideneamine) phenol in aqueous samples

    NASA Astrophysics Data System (ADS)

    Mirzaei, Mohammad; Saeed, Jaber

    2011-11-01

    A selective and sensitive chemosensor, based on the 2(4-hydroxy pent-3-en-2-ylideneamine) phenol (HPYAP) as chromophore, has been developed for colorimetric and visual detection of Ag(I) ions. HPYAP shows a considerable chromogenic behavior toward Ag(I) ions by changing the color of the solution from pale-yellow to very chromatic-yellow, which can be easily detected with the naked-eye. The chemosensor exhibited selective absorbance enhancement to Ag(I) ions in water samples over other metal ions at 438 nm, with a linear range of 0.4-500 μM ( r2 = 0.999) and a limit of detection 0.07 μM of Ag(I) ions with UV-vis spectrophotometer detection. The relative standard deviation (RSD) for 100 μM Ag(I) ions was 2.05% ( n = 7). The proposed method was applied for the determination Ag(I) ions in water and waste water samples.

  14. Portable Multispectral Colorimeter for Metallic Ion Detection and Classification.

    PubMed

    Braga, Mauro S; Jaimes, Ruth F V V; Borysow, Walter; Gomes, Osmar F; Salcedo, Walter J

    2017-07-28

    This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using optoelectronic multispectral sensors was fully integrated in the embedded hardware FPGA ( Field Programmable Gate Array) technology and software based on virtual instrumentation (NI LabView ® ). The system draws on an indicative colorimeter by using the chromogen reagent of 1-(2-pyridylazo)-2-naphthol (PAN). The results obtained with the signal processing and pattern analysis using the method of the linear discriminant analysis, allows excellent results during detection and classification of Pb(II), Cd(II), Zn(II), Cu(II), Fe(III) and Ni(II) ions, with almost the same level of performance as for those obtained from the Ultravioled and visible (UV-VIS) spectrophotometers of high spectral resolution.

  15. Method of fabricating bifacial tandem solar cells

    DOEpatents

    Wojtczuk, Steven J; Chiu, Philip T; Zhang, Xuebing; Gagnon, Edward; Timmons, Michael

    2014-10-07

    A method of fabricating on a semiconductor substrate bifacial tandem solar cells with semiconductor subcells having a lower bandgap than the substrate bandgap on one side of the substrate and with subcells having a higher bandgap than the substrate on the other including, first, growing a lower bandgap subcell on one substrate side that uses only the same periodic table group V material in the dislocation-reducing grading layers and bottom subcells as is present in the substrate and after the initial growth is complete and then flipping the substrate and growing the higher bandgap subcells on the opposite substrate side which can be of different group V material.

  16. Method of producing catalytic material for fabricating nanostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seals, Roland D.; Menchhofer, Paul A.; Howe, Jane Y.

    Methods of fabricating nano-catalysts are described. In some embodiments the nano-catalyst is formed from a powder-based substrate material and is some embodiments the nano-catalyst is formed from a solid-based substrate material. In some embodiments the substrate material may include metal, ceramic, or silicon or another metalloid. The nano-catalysts typically have metal nanoparticles disposed adjacent the surface of the substrate material. The methods typically include functionalizing the surface of the substrate material with a chelating agent, such as a chemical having dissociated carboxyl functional groups (--COO), that provides an enhanced affinity for metal ions. The functionalized substrate surface may then bemore » exposed to a chemical solution that contains metal ions. The metal ions are then bound to the substrate material and may then be reduced, such as by a stream of gas that includes hydrogen, to form metal nanoparticles adjacent the surface of the substrate.« less

  17. Method of producing catalytic materials for fabricating nanostructures

    DOEpatents

    Seals, Roland D; Menchhofer, Paul A; Howe, Jane Y; Wang, Wei

    2013-02-19

    Methods of fabricating nano-catalysts are described. In some embodiments the nano-catalyst is formed from a powder-based substrate material and is some embodiments the nano-catalyst is formed from a solid-based substrate material. In some embodiments the substrate material may include metal, ceramic, or silicon or another metalloid. The nano-catalysts typically have metal nanoparticles disposed adjacent the surface of the substrate material. The methods typically include functionalizing the surface of the substrate material with a chelating agent, such as a chemical having dissociated carboxyl functional groups (--COO), that provides an enhanced affinity for metal ions. The functionalized substrate surface may then be exposed to a chemical solution that contains metal ions. The metal ions are then bound to the substrate material and may then be reduced, such as by a stream of gas that includes hydrogen, to form metal nanoparticles adjacent the surface of the substrate.

  18. Reconditioning of semiconductor substrates to remove photoresist during semiconductor device fabrication

    DOEpatents

    Farino, Anthony J.

    2004-01-27

    A method for reconditioning the surface of a semiconductor substrate to remove an unwanted (i.e. defective) layer of photoresist is disclosed. The method adapts a conventional automated spinner which is used to rotate the substrate at high speed while a stream of a first solvent (e.g. acetone) is used to dissolve the photoresist. A stream of a second solvent (e.g. methanol) is then used to clean the substrate at a lower speed, with the substrate being allowed to dry with continued rotation. The method of the present invention can be used within a photolithography track so that the substrates need never leave the track for reconditioning.

  19. Simultaneous Determination of Iron, Copper and Cobalt in Food Samples by CCD-diode Array Detection-Flow Injection Analysis with Partial Least Squares Calibration Model

    NASA Astrophysics Data System (ADS)

    Mi, Jiaping; Li, Yuanqian; Zhou, Xiaoli; Zheng, Bo; Zhou, Ying

    2006-01-01

    A flow injection-CCD diode array detection spectrophotometry with partial least squares (PLS) program for simultaneous determination of iron, copper and cobalt in food samples has been established. The method was based on the chromogenic reaction of the three metal ions and 2- (5-Bromo-2-pyridylazo)-5-diethylaminophenol, 5-Br-PADAP in acetic acid - sodium acetate buffer solution (pH5) with Triton X-100 and ascorbic acid. The overlapped spectra of the colored complexes were collected by charge-coupled device (CCD) - diode array detector and the multi-wavelength absorbance data was processed using partial least squares (PLS) algorithm. Optimum reaction conditions and parameters of flow injection analysis were investigated. The samples of tea, sesame, laver, millet, cornmeal, mung bean and soybean powder were determined by the proposed method. The average recoveries of spiked samples were 91.80%~100.9% for Iron, 92.50%~108.0% for Copper, 93.00%~110.5% for Cobalt, respectively with relative standard deviation (R.S.D) of 1.1%~12.1%. The sampling rate is 45 samples h-1. The determination results of the food samples were in good agreement between the proposed method and ICP-AES.

  20. Western Blot of Stained Proteins from Dried Polyacrylamide Gels

    NASA Technical Reports Server (NTRS)

    Gruber, Claudia; Stan-Lotter, Helga

    1996-01-01

    Western blotting of proteins is customarily performed following their separation on polyacrylamide gels, either prior to staining (1) or, as recently reported, following staining (2). We describe here Western blotting with stained gels, which had been dried and some of which had been stored for years. This procedure permits immunological analysis of proteins, to which antisera may have become available only later, or where the application of newly developed sensitive detection methods is desired. Once rehydration of the gels is achieved, proteins can be-transferred to blotting membranes by any appropriate protocol. Proteins stained with Coomassie Blue have to be detected with a non-chromogenic method, such as the film-based enhanced chemiluminescence (ECL)2) procedure (3). Silver stained proteins, which transfer in the colorless form, may be visualized by any detection method, although, because of the usually very low amounts of proteins, detection by ECL is preferable. Blotting of stained proteins from rehydrated gels is as rapid and as quantitative as from freshly prepared gels, in contrast to blotting from wet stained gels, which requires extensive washing and results in low transfer efficiency (2). Together with a photographic record of the gel pattern, unambiguous identification of immunoreactive proteins from complex mixtures is possible. Some further applications of this work are discussed.

  1. Simple and Rapid Quantitative Determination of Thiol-Containing Toxicants Using Silver Nanoparticles as an Affinity Probe

    NASA Astrophysics Data System (ADS)

    Sharma, A.; Tapadia, K.

    2017-01-01

    A rapid and low-cost nano-drop spectrophotometric method using citrate-modified silver nanoparticles (Ag NPs) for the determination of thiol-containing toxicants was developed. The introduction of thioglycolic acid (TGA) and thiourea (TU) reduced the overall surface charge of Ag NPs, resulting in aggregation of Ag NPs, and a colorimetric response that was individually correlated with the concentration of TGA and TU. Under optimum experimental conditions, the maximum molar absorptivity values for TGA and TU were 1.04 × 105 and 2.13 × 105 L × mol-1 × cm-1, respectively, at λmax of 415 nm. The linear range used was 0.5-2.5 mg/L for TGA, and 0.3-1.5 mg/L for TU. The detection limits (3S) and % relative standard deviation (RSD) for the method were found to be 3 ppb, 2 ppb, and ±1.13%, ±0.96% for TGA and TU, respectively. This new chromogenic method provided a facile and sensitive scheme for the determination of TGA and TU, and could be applied for the determination of thiol-containing biomolecules. This scheme was tested for the analysis of real samples such as urine, blood, and environmental samples.

  2. Method for encapsulating and isolating hazardous cations, medium for encapsulating and isolating hazardous cations

    DOEpatents

    Wasserman, S.R.; Anderson, K.B.; Song, K.; Yuchs, S.E.; Marshall, C.L.

    1998-04-28

    A method for encapsulating hazardous cations is provided comprising supplying a pretreated substrate containing the cations; contacting the substrate with an organo-silane compound to form a coating on the substrate; and allowing the coating to cure. A medium for containing hazardous cations is also provided, comprising a substrate having ion-exchange capacity and a silane-containing coating on the substrate. 3 figs.

  3. An enzyme-mediated protein-fragment complementation assay for substrate screening of sortase A.

    PubMed

    Li, Ning; Yu, Zheng; Ji, Qun; Sun, Jingying; Liu, Xiao; Du, Mingjuan; Zhang, Wei

    2017-04-29

    Enzyme-mediated protein conjugation has gained great attention recently due to the remarkable site-selectivity and mild reaction condition affected by the nature of enzyme. Among all sorts of enzymes reported, sortase A from Staphylococcus aureus (SaSrtA) is the most popular enzyme due to its selectivity and well-demonstrated applications. Position scanning has been widely applied to understand enzyme substrate specificity, but the low throughput of chemical synthesis of peptide substrates and analytical methods (HPLC, LC-ESI-MS) have been the major hurdle to fully decode enzyme substrate profile. We have developed a simple high-throughput substrate profiling method to reveal novel substrates of SaSrtA 7M, a widely used hyperactive peptide ligase, by modified protein-fragment complementation assay (PCA). A small library targeting the LPATG motif recognized by SaSrtA 7M was generated and screened against proteins carrying N-terminal glycine. Using this method, we have confirmed all currently known substrates of the enzyme, and moreover identified some previously unknown substrates with varying activities. The method provides an easy, fast and highly-sensitive way to determine substrate profile of a peptide ligase in a high-throughput manner. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Method for producing high quality thin layer films on substrates

    DOEpatents

    Strongin, Myron; Ruckman, Mark; Strongin, Daniel

    1994-01-01

    A method for producing high quality, thin layer films of inorganic compounds upon the surface of a substrate is disclosed. The method involves condensing a mixture of preselected molecular precursors on the surface of a substrate and subsequently inducing the formation of reactive species using high energy photon or charged particle irradiation. The reactive species react with one another to produce a film of the desired compound upon the surface of the substrate.

  5. Prophylaxis vs. on-demand treatment with BAY 81-8973, a full-length plasma protein-free recombinant factor VIII product: results from a randomized trial (LEOPOLD II)

    PubMed Central

    Kavakli, K; Yang, R; Rusen, L; Beckmann, H; Tseneklidou-Stoeter, D; Maas Enriquez, M

    2015-01-01

    Background BAY 81-8973 is a new full-length human recombinant factor VIII product manufactured with technologies to improve consistency in glycosylation and expression to optimize clinical performance. Objectives To demonstrate superiority of prophylaxis vs. on-demand therapy with BAY 81-8973 in patients with severe hemophilia A. Patients/Methods In this multinational, randomized, open-label crossover study (LEOPOLD II; ClinicalTrials.gov identifier: NCT01233258), males aged 12–65 years with severe hemophilia A were randomized to twice-weekly prophylaxis (20–30 IU kg−1), 3-times-weekly prophylaxis (30–40 IU kg−1), or on-demand treatment with BAY 81-8973. Potency labeling for BAY 81-8973 was based on the chromogenic substrate assay or adjusted to the one-stage assay. Primary efficacy endpoint was annualized number of all bleeds (ABR). Adverse events (AEs) and immunogenicity were also assessed. Results Eighty patients (on demand, n = 21; twice-weekly prophylaxis, n = 28; 3-times-weekly prophylaxis, n = 31) were treated and analyzed. Mean ± SD ABR was significantly lower with prophylaxis (twice-weekly, 5.7 ± 7.2; 3-times-weekly, 4.3 ± 6.5; combined, 4.9 ± 6.8) vs. on-demand treatment (57.7 ± 24.6; P < 0.0001, anova). Median ABR was reduced by 97% with prophylaxis (twice-weekly, 4.0; 3-times-weekly, 2.0; combined, 2.0) vs. on-demand treatment (60.0). Median ABR was higher with twice-weekly vs. 3-times-weekly prophylaxis during the first 6-month treatment period (4.1 vs. 2.0) but was comparable in the second 6-month period (1.1 vs. 2.0). Few patients reported treatment-related AEs (4%); no treatment-related serious AEs or inhibitors were reported. Conclusions Twice-weekly or 3-times-weekly prophylaxis with BAY 81-8973 reduced median ABR by 97% compared with on-demand therapy, confirming the superiority of prophylaxis. Treatment with BAY 81-8973 was well tolerated. PMID:25546368

  6. Passivated contact formation using ion implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, David L.; Stradins, Pauls; Nemeth, William

    2018-05-29

    Methods for forming passivated contacts include implanting compound-forming ions into a substrate to about a first depth below a surface of the substrate, and implanting dopant ions into the substrate to about a second depth below the surface. The second depth may be shallower than the first depth. The methods also include annealing the substrate.

  7. Ordered adsorption of coagulation factor XII on negatively charged polymer surfaces probed by sum frequency generation vibrational spectroscopy.

    PubMed

    Chen, Xiaoyun; Wang, Jie; Paszti, Zoltan; Wang, Fulin; Schrauben, Joel N; Tarabara, Volodymyr V; Schmaier, Alvin H; Chen, Zhan

    2007-05-01

    Electrostatic interactions between negatively charged polymer surfaces and factor XII (FXII), a blood coagulation factor, were investigated by sum frequency generation (SFG) vibrational spectroscopy, supplemented by several analytical techniques including attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), quartz crystal microbalance (QCM), zeta-potential measurement, and chromogenic assay. A series of sulfonated polystyrenes (sPS) with different sulfonation levels were synthesized as model surfaces with different surface charge densities. SFG spectra collected from FXII adsorbed onto PS and sPS surfaces with different surface charge densities showed remarkable differences in spectral features and especially in spectral intensity. Chromogenic assay experiments showed that highly charged sPS surfaces induced FXII autoactivation. ATR-FTIR and QCM results indicated that adsorption amounts on the PS and sPS surfaces were similar even though the surface charge densities were different. No significant conformational change was observed from FXII adsorbed onto surfaces studied. Using theoretical calculations, the possible contribution from the third-order nonlinear optical effect induced by the surface electric field was evaluated, and it was found to be unable to yield the SFG signal enhancement observed. Therefore it was concluded that the adsorbed FXII orientation and ordering were the main reasons for the remarkable SFG amide I signal increase on sPS surfaces. These investigations indicate that negatively charged surfaces facilitate or induce FXII autoactivation on the molecular level by imposing specific orientation and ordering on the adsorbed protein molecules.

  8. Chromogenic behaviors of the Humboldt squid (Dosidicus gigas) studied in situ with an animal-borne video package.

    PubMed

    Rosen, Hannah; Gilly, William; Bell, Lauren; Abernathy, Kyler; Marshall, Greg

    2015-01-15

    Dosidicus gigas (Humboldt or jumbo flying squid) is an economically and ecologically influential species, yet little is known about its natural behaviors because of difficulties in studying this active predator in its oceanic environment. By using an animal-borne video package, National Geographic's Crittercam, we were able to observe natural behaviors in free-swimming D. gigas in the Gulf of California with a focus on color-generating (chromogenic) behaviors. We documented two dynamic displays without artificial lighting at depths of up to 70 m. One dynamic pattern, termed 'flashing' is characterized by a global oscillation (2-4 Hz) of body color between white and red. Flashing was almost always observed when other squid were visible in the video frame, and this behavior presumably represents intraspecific signaling. Amplitude and frequency of flashing can be modulated, and the phase relationship with another squid can also be rapidly altered. Another dynamic display termed 'flickering' was observed whenever flashing was not occurring. This behavior is characterized by irregular wave-like activity in neighboring patches of chromatophores, and the resulting patterns mimic reflections of down-welled light in the water column, suggesting that this behavior may provide a dynamic type of camouflage. Rapid and global pauses in flickering, often before a flashing episode, indicate that flickering is under inhibitory neural control. Although flashing and flickering have not been described in other squid, functional similarities are evident with other species. © 2015. Published by The Company of Biologists Ltd.

  9. Dual-colour HER2/chromosome 17 chromogenic in situ hybridisation enables accurate assessment of HER2 genomic status in ovarian tumours.

    PubMed

    Yan, Benedict; Choo, Shoa Nian; Mulyadi, Patricia; Srivastava, Supriya; Ong, Chee Wee; Yong, Kol Jia; Putti, Thomas; Salto-Tellez, Manuel; Lim, Gkeok Stzuan Diana

    2011-12-01

    Ovarian cancer is a leading cause of gynaecological cancer-related morbidity and mortality. There has been increasing interest in the potential utility of anti-human epidermal growth factor receptor 2 (anti-HER2) agents in the treatment of this disease, with the attendant need to identify suitable predictive biomarkers of response to treatment. The authors studied the prevalence of HER2 genomic amplification and overexpression in 85 ovarian tumours in the local patient cohort of this study, as well as the concordance rate between immunohistochemistry, fluorescent in situ hybridisation (FISH) and a dual-colour HER2/chromosome 17 centromere chromogenic in situ hybridisation (CISH) assay. The authors identified HER2 genomic amplification and protein overexpression in 35.3% (6/17) and 29.4% (5/17), respectively, of primary ovarian mucinous carcinomas. No other cancer subtypes displayed HER2 amplification or protein overexpression. The authors also found a perfect concordance between FISH and dual-colour CISH analysis (κ coefficient 1.0, p<0.001). The results of this study support existing reports that HER2 genomic amplification and protein overexpression are predominantly found in primary ovarian mucinous carcinomas. Given the perfect concordance between the FISH and dual-colour CISH assays and the advantages of CISH over FISH analysis, future clinical trials investigating the use of anti-HER2 therapeutics in ovarian carcinomas should incorporate dual-colour CISH as part of the HER2 status assessment algorithm.

  10. Method for masking selected regions of a substrate

    DOEpatents

    Fusaro, Jr., Robert Anthony; Bethel, Timothy Francis

    2010-05-04

    Described herein is a method for providing a clean edge at the interface of a portion of a substrate coated with a coating system and an adjacent portion of the substrate which is uncoated. The method includes the step of forming a zone of non-adherence on the substrate portion which is to be uncoated, prior to application of the coating system. The zone of non-adherence is adjacent the interface, so that the coating system will not adhere to the zone of non-adherence, but will adhere to the portion of the substrate which is to be coated with the coating system.

  11. Method For Making Selected Regions Of A Substrate

    DOEpatents

    Fusaro, Jr., Robert Anthony; Bethel, Timothy Francis

    2003-07-15

    Described herein is a method for providing a clean edge at the interface of a portion of a substrate coated with a coating system and an adjacent portion of the substrate which is uncoated. The method includes the step of forming a zone of non-adherence on the substrate portion which is to be uncoated, prior to application of the coating system. The zone of non-adherence is adjacent the interface, so that the coating system will not adhere to the zone of non-adherence, but will adhere to the portion of the substrate which is to be coated with the coating system.

  12. The use of skin Fe levels as a surrogate marker for organ Fe levels, to monitor treatment in cases of iron overload

    NASA Astrophysics Data System (ADS)

    Farquharson, Michael J.; Bagshaw, Andrew P.; Porter, John B.; Abeysinghe, R. D.

    2000-05-01

    A system based on the detection of K-shell x-ray fluorescence (XRF) has been used to investigate whether a correlation exists between the concentration of iron in the skin and the concentration of iron in the liver, as the degree of iron loading increases. The motivation behind this work is to develop a non-invasive method of determining the extent of the body's iron stores via measurements on the skin, in order to monitor the efficacy of chelation therapy administered to patients with β-thalassaemia. Sprague-Dawley rats were iron loaded via injections of iron dextran and subsequently treated with the iron chelator CP94. The non-haem iron concentrations of the liver, heart and spleen were determined using bathophenanthroline sulphonate as the chromogen reagent. Samples of abdominal skin were taken and the iron concentrations determined using XRF. A strong correlation between the skin iron concentration and the liver iron concentration has been demonstrated (R2 = 0.86). Similar correlations exist for the heart and the spleen. These results show that this method holds great potential as a tool in the diagnosis and treatment of hereditary haemochromatosis and β-thalassaemia.

  13. A new rapid immunohistochemical staining technique using the EnVision antibody complex.

    PubMed

    Kämmerer, U; Kapp, M; Gassel, A M; Richter, T; Tank, C; Dietl, J; Ruck, P

    2001-05-01

    Rapid immunohistochemical investigation, in addition to staining with hematoxylin and eosin, would be useful during intraoperative frozen section diagnosis in some cases. This study was undertaken to investigate whether the recently described EnVision system, a highly sensitive two-step immunohistochemical technique, could be modified for rapid immunostaining of frozen sections. Forty-five primary antibodies were tested on frozen sections from various different tissues. After fixation in acetone for 1 min and air-drying, the sections were incubated for 3 min each with the primary antibody, the EnVision complex (a large number of secondary antibodies and horseradish peroxidase coupled to a dextran backbone), and the chromogen (3,3'diaminobenzidine or 3-amino-9-ethylcarbazole). All reactions were carried out at 37C. Specific staining was seen with 38 antibodies (including HMB-45 and antibodies against keratin, vimentin, leukocyte common antigen, smooth muscle actin, synaptophysin, CD34, CD3, CD20, and prostate-specific antigen). A modification of the EnVision method allows the detection of a broad spectrum of antigens in frozen sections in less than 13 min. This method could be a useful new tool in frozen section diagnosis and research. (J Histochem Cytochem 49:623-630, 2001)

  14. Detection of Streptococcus pyogenes using rapid visual molecular assay.

    PubMed

    Zhao, Xiangna; He, Xiaoming; Li, Huan; Zhao, Jiangtao; Huang, Simo; Liu, Wei; Wei, Xiao; Ding, Yiwei; Wang, Zhaoyan; Zou, Dayang; Wang, Xuesong; Dong, Derong; Yang, Zhan; Yan, Xiabei; Huang, Liuyu; Du, Shuangkui; Yuan, Jing

    2015-09-01

    Streptococcus pyogenes is an increasingly important pathogen in many parts of the world. Rapid and accurate detection of S. pyogenes aids in the control of the infection. In this study, a loop-mediated isothermal amplification (LAMP) assay was developed and validated for the specific detection of S. pyogenes. The assay incorporates two methods: a chromogenic analysis using a calcein/Mn(2+) complex and real-time turbidity monitoring to assess the reaction. Both methods detected the target DNA within 60 min under 64°C isothermal conditions. The assay used specifically designed primers to target spy1258, and correctly identified 111 strains of S. pyogenes and 32 non-S. pyogenes strains, including other species of the genus Streptococcus. Tests using reference strains showed that the LAMP assay was highly specific. The sensitivity of the assay, with a detection limit of 1.49 pg DNA, was 10-fold greater than that of PCR. The LAMP assay established in this study is simple, fast and sensitive, and does not rely upon any special equipment; thus, it could be employed in clinical diagnosis. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Assessment of microbiological quality of drinking water from household tanks in Bermuda.

    PubMed

    Lévesque, B; Pereg, D; Watkinson, E; Maguire, J S; Bissonnette, L; Gingras, S; Rouja, P; Bergeron, M G; Dewailly, E

    2008-06-01

    Bermuda residents collect rainwater from rooftops to fulfil their freshwater needs. The objective of this study was to assess the microbiological quality of drinking water in household tanks throughout Bermuda. The tanks surveyed were selected randomly from the electoral register. Governmental officers visited the selected household (n = 102) to collect water samples and administer a short questionnaire about the tank characteristics, the residents' habits in terms of water use, and general information on the water collecting system and its maintenance. At the same time, water samples were collected for analysis and total coliforms and Escherichia coli were determined by 2 methods (membrane filtration and culture on chromogenic media, Colilert kit). Results from the 2 methods were highly correlated and showed that approximately 90% of the samples analysed were contaminated with total coliforms in concentrations exceeding 10 CFU/100 mL, and approximately 66% of samples showed contamination with E. coli. Tank cleaning in the year prior to sampling seems to protect against water contamination. If rainwater collection from roofs is the most efficient mean for providing freshwater to Bermudians, it must not be considered a source of high quality drinking water because of the high levels of microbial contamination.

  16. Method for fabricating {sup 99}Mo production targets using low enriched uranium, {sup 99}Mo production targets comprising low enriched uranium

    DOEpatents

    Wiencek, T.C.; Matos, J.E.; Hofman, G.L.

    1997-03-25

    A radioisotope production target and a method for fabricating a radioisotope production target is provided, wherein the target comprises an inner cylinder, a foil of fissionable material circumferentially contacting the outer surface of the inner cylinder, and an outer hollow cylinder adapted to receive the substantially foil-covered inner cylinder and compress tightly against the foil to provide good mechanical contact therewith. The method for fabricating a primary target for the production of fission products comprises preparing a first substrate to receive a foil of fissionable material so as to allow for later removal of the foil from the first substrate, preparing a second substrate to receive the foil so as to allow for later removal of the foil from the second substrate; attaching the first substrate to the second substrate such that the foil is sandwiched between the first substrate and second substrate to prevent foil exposure to ambient atmosphere, and compressing the exposed surfaces of the first and second substrate to assure snug mechanical contact between the foil, the first substrate and the second substrate. 3 figs.

  17. Method for producing high quality thin layer films on substrates

    DOEpatents

    Strongin, M.; Ruckman, M.; Strongin, D.

    1994-04-26

    A method for producing high quality, thin layer films of inorganic compounds upon the surface of a substrate is disclosed. The method involves condensing a mixture of preselected molecular precursors on the surface of a substrate and subsequently inducing the formation of reactive species using high energy photon or charged particle irradiation. The reactive species react with one another to produce a film of the desired compound upon the surface of the substrate. 4 figures.

  18. Method for removing semiconductor layers from salt substrates

    DOEpatents

    Shuskus, Alexander J.; Cowher, Melvyn E.

    1985-08-27

    A method is described for removing a CVD semiconductor layer from an alkali halide salt substrate following the deposition of the semiconductor layer. The semiconductor-substrate combination is supported on a material such as tungsten which is readily wet by the molten alkali halide. The temperature of the semiconductor-substrate combination is raised to a temperature greater than the melting temperature of the substrate but less than the temperature of the semiconductor and the substrate is melted and removed from the semiconductor by capillary action of the wettable support.

  19. The facile flow-injection spectrophotometric detection of gold(III) in water and pharmaceutical samples using 3,5-dimethoxy-4-hydroxy-2-aminoacetophenone isonicotinoyl hydrazone (3,5-DMHAAINH).

    PubMed

    Babu, S Hari; Suvardhan, K; Kumar, K Suresh; Reddy, K M; Rekha, D; Chiranjeevi, P

    2005-04-11

    A simple, sensitive and rapid flow-injection spectrophotometric method was developed for the determination of trace amounts of Au(III) in aqueous dimethylformamide (DMF). The method is based on formation of Au(III)-(3,5-DMHAAINH)3 complex. The optimum conditions for the chromogenic reaction of Au(III) with 3,5-DMHAAINH is studied and the colored (reddish brown) complex is selectively monitored at lambda(max) 490 nm at pH 6.0. The reaction and flow conditions of the full experimental design were optimized. The detection limit (2 s) of 0.1 microg l-1 Au(III) was obtained at a sampling rate of 15 samples h-1. Beer's law is obeyed over the range of 0.30-4.00 microg ml-1. The molar absorptivity and Sandell's sensitivity were 3.450x10(4) M and 0.0050 microg ml-1, respectively. Job's method of continuous variation and stability constants corresponding to these maxima was determined and found to be 9.3x10(15) (1:3, M:R) (M, metal; R, reagent). The detailed study of various interferences confirmed the high selectivity of the developed method. The method was successfully applied for the determination of trace amount of Au(III) in water and pharmaceutical samples. The results obtained were in agreement with the reported methods at the 95% confidence level.

  20. Comparison of four β-glucuronidase and β-galactosidase-based commercial culture methods used to detect Escherichia coli and total coliforms in water.

    PubMed

    Maheux, Andrée F; Dion-Dupont, Vanessa; Bouchard, Sébastien; Bisson, Marc-Antoine; Bergeron, Michel G; Rodriguez, Manuel J

    2015-06-01

    The MI agar, Colilert(®), Chromocult coliform(®) agar, and DC with BCIG agar chromogenic culture-based methods used to assess microbiological quality of drinking water were compared in terms of their ubiquity, sensitivity, ease of use, growth of atypical colonies and affordability. For ubiquity, 129 total coliform (representing 76 species) and 19 Escherichia coli strains were tested. Then, 635 1-L well water samples were divided into 100 mL subsamples for testing by all four methods. Test results showed that 70.5, 52.7, 36.4, and 23.3% of the non-E. coli total coliform strains and 94.7, 94.7, 89.5, and 89.5% of the 19 E. coli strains yielded a positive signal with the four methods, respectively. They also yielded a total coliform positive signal for 66.5, 51.7, 64.9, and 55.0% and an E. coli positive signal for 16.1, 14.8, 17.3, and 13.4% of the 635 well water samples tested, respectively. Results showed that Colilert(®) is the most expensive method tested in terms of reactants, yet it is the easiest to use. Large numbers of atypical colonies were also often observed on Chromocult coliform(®) and DC with BCIG, thereby challenging the target microorganism count. Thus, the MI agar method seems to be the best option for the assessment of drinking water quality.

  1. The usefulness of DNA sequencing after extraction by Whatman FTA filter matrix technology and phenotypic tests for differentiation of Candida albicans and Candida dubliniensis.

    PubMed

    Kiraz, Nuri; Oz, Yasemin; Aslan, Huseyin; Muslumanoglu, Hamza

    2014-02-01

    Since C. dubliniensis is similar to C. albicans phenotypically, it can be misidentified as C. albicans. We aimed to investigate the prevalence of C. dubliniensis among isolates previously identified as C. albicans in our stocks and to compare the phenotypic methods and DNA sequencing of D1/D2 region on the ribosomal large subunit (rLSU) gene. A total of 850 isolates included in this study. Phenotypic identification was performed based on germ tube formation, chlamydospore production, colony colors on chromogenic agar, inability of growth at 45 °C and growth on hypertonic Sabouraud dextrose agar. Eighty isolates compatible with C. dubliniensis by at least one phenotypic test were included in the sequence analysis. Nested PCR amplification of D1/D2 region of the rLSU gene was performed after the fungal DNA extraction by Whatman FTA filter paper technology. The sequencing analysis of PCR products carried out by an automated capillary gel electrophoresis device. The rate of C. dubliniensis was 2.35 % (n = 20) among isolates previously described as C. albicans. Consequently, none of the phenotypic tests provided satisfactory performance alone in our study, and molecular methods required special equipment and high cost. Thus, at least two phenotypic methods can be used for identification of C. dubliniensis, and molecular methods can be used for confirmation.

  2. [Comparison between conventional methods, ChromAgar Candida® and PCR method for the identification of Candida species in clinical isolates].

    PubMed

    Estrada-Barraza, Deyanira; Dávalos Martínez, Arturo; Flores-Padilla, Luis; Mendoza-De Elias, Roberto; Sánchez-Vargas, Luis Octavio

    2011-01-01

    The increase in the incidence of yeast species causing fungemia in susceptible immunocompromised patients in the last two decades and the low sensitivity of conventional blood culture has led to the need to develop alternative approaches for the early detection and identification of causative species. The aim of this study was to compare the usefulness of molecular testing by the polymerase chain reaction (PCR) and conventional methods to identify clinical isolates of different species, using the ID32C ATB system (bioMérieux, France), chromogenic culture Chromagar Candida® (CHROMagar, France) and morphogenesis in corn meal agar. We studied 79 isolates, in which the most prevalent species using the system ID32C and PCR was C. albicans, followed by C. tropicalis, C. glabrata and C .krusei. PCR patterns obtained for the identification of clinical isolates were stable and consistent in the various independent studies and showed good reproducibility, concluding that PCR with species-specific primers that amplify genes ITS1 and ITS2 for rRNA or topoisomerase II primers is a very specific and sensitive method for the identification of C. glabrata, C. krusei, C. albicans, and with less specificity for C. tropicalis. Copyright © 2010 Revista Iberoamericana de Micología. Published by Elsevier Espana. All rights reserved.

  3. Selective functional activity measurement of a PEGylated protein with a modification-dependent activity assay.

    PubMed

    Weber, Alfred; Engelmaier, Andrea; Mohr, Gabriele; Haindl, Sonja; Schwarz, Hans Peter; Turecek, Peter L

    2017-01-05

    BAX 855 (ADYNOVATE) is a PEGylated recombinant factor VIII (rFVIII) that showed prolonged circulatory half-life compared to unmodified rFVIII in hemophilic patients. Here, the development and validation of a novel assay is described that selectively measures the activity of BAX 855 as cofactor for the serine protease factor IX, which actives factor X. This method type, termed modification-dependent activity assay, is based on PEG-specific capture of BAX 855 by an anti-PEG IgG preparation, followed by a chromogenic FVIII activity assay. The assay principle enabled sensitive measurement of the FVIII cofactor activity of BAX 855 down to the pM-range without interference by non-PEGylated FVIII. The selectivity of the capture step, shown by competition studies to primarily target the terminal methoxy group of PEG, also allowed assessment of the intactness of the attached PEG chains. Altogether, the modification-dependent activity not only enriches, but complements the group of methods to selectively, accurately, and precisely measure a PEGylated drug in complex biological matrices. In contrast to all other methods described so far, it allows measurement of the biological activity of the PEGylated protein. Data obtained demonstrate that this new method principle can be extended to protein modifications other than PEGylation and to a variety of functional activity assays. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Initiation devices, initiation systems including initiation devices and related methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniels, Michael A.; Condit, Reston A.; Rasmussen, Nikki

    Initiation devices may include at least one substrate, an initiation element positioned on a first side of the at least one substrate, and a spark gap electrically coupled to the initiation element and positioned on a second side of the at least one substrate. Initiation devices may include a plurality of substrates where at least one substrate of the plurality of substrates is electrically connected to at least one adjacent substrate of the plurality of substrates with at least one via extending through the at least one substrate. Initiation systems may include such initiation devices. Methods of igniting energetic materialsmore » include passing a current through a spark gap formed on at least one substrate of the initiation device, passing the current through at least one via formed through the at least one substrate, and passing the current through an explosive bridge wire of the initiation device.« less

  5. Method for fabricating an ultra-low expansion mask blank having a crystalline silicon layer

    DOEpatents

    Cardinale, Gregory F.

    2002-01-01

    A method for fabricating masks for extreme ultraviolet lithography (EUVL) using Ultra-Low Expansion (ULE) substrates and crystalline silicon. ULE substrates are required for the necessary thermal management in EUVL mask blanks, and defect detection and classification have been obtained using crystalline silicon substrate materials. Thus, this method provides the advantages for both the ULE substrate and the crystalline silicon in an Extreme Ultra-Violet (EUV) mask blank. The method is carried out by bonding a crystalline silicon wafer or member to a ULE wafer or substrate and thinning the silicon to produce a 5-10 .mu.m thick crystalline silicon layer on the surface of the ULE substrate. The thinning of the crystalline silicon may be carried out, for example, by chemical mechanical polishing and if necessary or desired, oxidizing the silicon followed by etching to the desired thickness of the silicon.

  6. Dependence of the critical temperature of laser-ablated YBa2Cu3O(7-delta) thin films on LaAlO3 substrate growth technique

    NASA Technical Reports Server (NTRS)

    Warner, Joseph D.; Bhasin, Kul B.; Miranda, Felix A.

    1991-01-01

    Samples of LaAlO3 made by flame fusion and Czochralski method were subjected to the same temperature conditions that they have to undergo during the laser ablation deposition of YBa2Cu3O(7 - delta) thin films. After oxygen annealing at 750 C, the LaAlO3 substrate made by two methods experienced surface roughening. The degree of roughening on the substrate made by Czochralski method was three times greater than that on the substrate made by flame fusion. This excessive surface roughening may be the origin of the experimentally observed lowering of the critical temperature of a film deposited by laser ablation on a LaAlO3 substrate made by Czochralski method with respect to its counterpart deposited on LaAlO3 substrates made by flame fusion.

  7. Method of forming through substrate vias (TSVs) and singulating and releasing die having the TSVs from a mechanical support substrate

    DOEpatents

    Okandan, Murat; Nielson, Gregory N

    2014-12-09

    Accessing a workpiece object in semiconductor processing is disclosed. The workpiece object includes a mechanical support substrate, a release layer over the mechanical support substrate, and an integrated circuit substrate coupled over the release layer. The integrated circuit substrate includes a device layer having semiconductor devices. The method also includes etching through-substrate via (TSV) openings through the integrated circuit substrate that have buried ends at or within the release layer including using the release layer as an etch stop. TSVs are formed by introducing one or more conductive materials into the TSV openings. A die singulation trench is etched at least substantially through the integrated circuit substrate around a perimeter of an integrated circuit die. The integrated circuit die is at least substantially released from the mechanical support substrate.

  8. Method for fabricating a substrate having spaced apart microcapillaries thereon

    DOEpatents

    Jarvis, Eric E.

    1995-01-01

    Methods for manufacturing a self-supporting substrate having a plurality of spaced-apart needles (spikes or microcapillaries) projecting upwardly from a major surface of the substrate. In a preferred method, metal is deposited onto a porous membrane such that the metal extends into the pores, after which the membrane is dissolved.

  9. Structure having spatially separated photo-excitable electron-hole pairs and method of manufacturing same

    DOEpatents

    Liang, Yong [Richland, WA; Daschbach, John L [Richland, WA; Su, Yali [Richland, WA; Chambers, Scott A [Kennewick, WA

    2006-08-22

    A method for producing quantum dots. The method includes cleaning an oxide substrate and separately cleaning a metal source. The substrate is then heated and exposed to the source in an oxygen environment. This causes metal oxide quantum dots to form on the surface of the substrate.

  10. Structure having spatially separated photo-excitable electron-hole pairs and method of manufacturing same

    DOEpatents

    Liang, Yong [Richland, WA; Daschbach, John L [Richland, WA; Su, Yali [Richland, WA; Chambers, Scott A [Kennewick, WA

    2003-03-18

    A method for producing quantum dots. The method includes cleaning an oxide substrate and separately cleaning a metal source. The substrate is then heated and exposed to the source in an oxygen environment. This causes metal oxide quantum dots to form on the surface of the substrate.

  11. Method for preparation of thermally and mechanically stable metal/porous substrate composite membranes

    DOEpatents

    Damle, Ashok S.

    2004-07-13

    A method is provided for the preparation of metal/porous substrate composite membranes by flowing a solution of metal to be plated over a first surface of a porous substrate and concurrently applying a pressure of gas on a second surface of the porous substrate, such that the porous substrate separates the solution of metal from the gas, and the use of the resulting membrane for the production of highly purified hydrogen gas.

  12. Method of fabricating low-dislocation-density epitaxially-grown films with textured surfaces

    DOEpatents

    Li, Qiming; Wang, George T

    2015-01-13

    A method for forming a surface-textured single-crystal film layer by growing the film atop a layer of microparticles on a substrate and subsequently selectively etching away the microparticles to release the surface-textured single-crystal film layer from the substrate. This method is applicable to a very wide variety of substrates and films. In some embodiments, the film is an epitaxial film that has been grown in crystallographic alignment with respect to a crystalline substrate.

  13. Method for improving the oxidation-resistance of metal substrates coated with thermal barrier coatings

    DOEpatents

    Thompson, Anthony Mark; Gray, Dennis Michael; Jackson, Melvin Robert

    2002-01-01

    A method for providing a protective coating on a metal-based substrate is disclosed. The method involves the application of an aluminum-rich mixture to the substrate to form a discontinuous layer of aluminum-rich particles, followed by the application of a second coating over the discontinuous layer of aluminum-rich particles. Aluminum diffuses from the aluminum-rich layer into the substrate, and into any bond coat layer which is subsequently applied. Related articles are also described.

  14. Layered devices having surface curvature and method of constructing same

    DOEpatents

    Woodbury, Richard C.; Perkins, Raymond T.; Thorne, James M.

    1989-01-01

    A method of treating a substrate having first and second sides with corresponding oppositely facing first and second surfaces, to produce curvature in the first surface. The method includes the steps of removing material, according to a predetermined pattern, from the second side of the substrate, and applying a stress-producing film of material to at least one surface of the substrate to thereby cause the substrate to bend to produce the desired curvature in the first surface.

  15. Spectrophotometric determination of substrate-borne polyacrylamide.

    PubMed

    Lu, Jianhang; Wu, Laosheng

    2002-08-28

    Polyacrylamides (PAMs) have wide application in many industries and in agriculture. Scientific research and industrial applications manifested a need for a method that can quantify substrate-borne PAM. The N-bromination method (a PAM analytical technique based on N-bromination of amide groups and spectrophotometric determination of the formed starch-triiodide complex), which was originally developed for determining PAM in aqueous solutions, was modified to quantify substrate-borne PAM. In the modified method, the quantity of substrate-borne PAM was converted to a concentration of starch-triiodide complex in aqueous solution that was then measured by spectrophotometry. The method sensitivity varied with substrates due to sorption of reagents and reaction intermediates on the substrates. Therefore, separate calibration for each substrate was required. Results from PAM samples in sand, cellulose, organic matter burnt soils, and clay minerals showed that this method had good accuracy and reproducibility. The PAM recoveries ranged from 95.8% to 103.7%, and the relative standard deviations (n = 4) were <7.5% in all cases. The optimum range of PAM in each sample is 10-80 microg. The technique can serve as an effective tool in improving PAM application and facilitating PAM-related research.

  16. Method for wetting a boron alloy to graphite

    DOEpatents

    Storms, E.K.

    1987-08-21

    A method is provided for wetting a graphite substrate and spreading a a boron alloy over the substrate. The wetted substrate may be in the form of a needle for an effective ion emission source. The method may also be used to wet a graphite substrate for subsequent joining with another graphite substrate or other metal, or to form a protective coating over a graphite substrate. A noneutectic alloy of boron is formed with a metal selected from the group consisting of nickel (Ni), palladium (Pd), and platinum (Pt) with excess boron, i.e., and atomic percentage of boron effective to precipitate boron at a wetting temperature of less than the liquid-phase boundary temperature of the alloy. The alloy is applied to the substrate and the graphite substrate is then heated to the wetting temperature and maintained at the wetting temperature for a time effective for the alloy to wet and spread over the substrate. The excess boron is evenly dispersed in the alloy and is readily available to promote the wetting and spreading action of the alloy. 1 fig.

  17. Line-of-sight deposition method

    DOEpatents

    Patten, J.W.; McClanahan, E.D.; Bayne, M.A.

    1980-04-16

    A line-of-sight method of depositing a film having substantially 100% of theoretical density on a substrate. A pressure vessel contains a target source having a surface thereof capable of emitting particles therefrom and a substrate with the source surface and the substrate surface positioned such that the source surface is substantially parallel to the direction of the particles impinging upon the substrate surface, the distance between the most remote portion of the substrate surface receiving the particles and the source surface emitting the particles in a direction parallel to the substrate surface being relatively small. The pressure in the vessel is maintained less than about 5 microns to prevent scattering and permit line-of-sight deposition. By this method the angles of incidence of the particles impinging upon the substrate surface are in the range of from about 45/sup 0/ to 90/sup 0/ even when the target surface area is greatly expanded to increase the deposition rate.

  18. Line-of-sight deposition method

    DOEpatents

    Patten, James W.; McClanahan, Edwin D.; Bayne, Michael A.

    1981-01-01

    A line-of-sight method of depositing a film having substantially 100% of theoretical density on a substrate. A pressure vessel contains a target source having a surface thereof capable of emitting particles therefrom and a substrate with the source surface and the substrate surface positioned such that the source surface is substantially parallel to the direction of the particles impinging upon the substrate surface, the distance between the most remote portion of the substrate surface receiving the particles and the source surface emitting the particles in a direction parallel to the substrate surface being relatively small. The pressure in the vessel is maintained less than about 5 microns to prevent scattering and permit line-of-sight deposition. By this method the angles of incidence of the particles impinging upon the substrate surface are in the range of from about 45.degree. to 90.degree. even when the target surface area is greatly expanded to increase the deposition rate.

  19. Corrosion resistant coating

    DOEpatents

    Wrobleski, D.A.; Benicewicz, B.C.; Thompson, K.G.; Bryan, C.J.

    1997-08-19

    A method of protecting a metal substrate from corrosion including coating a metal substrate of, e.g., steel, iron or aluminum, with a conductive polymer layer of, e.g., polyaniline, coating upon said metal substrate, and coating the conductive polymer-coated metal substrate with a layer of a topcoat upon the conductive polymer coating layer, is provided, together with the resultant coated article from said method.

  20. Corrosion resistant coating

    DOEpatents

    Wrobleski, Debra A.; Benicewicz, Brian C.; Thompson, Karen G.; Bryan, Coleman J.

    1997-01-01

    A method of protecting a metal substrate from corrosion including coating a metal substrate of, e.g., steel, iron or aluminum, with a conductive polymer layer of, e.g., polyaniline, coating upon said metal substrate, and coating the conductive polymer-coated metal substrate with a layer of a topcoat upon the conductive polymer coating layer, is provided, together with the resultant coated article from said method.

  1. Method for fabricating a substrate having spaced apart microcapillaries thereon

    DOEpatents

    Jarvis, E.E.

    1995-01-24

    Methods are disclosed for manufacturing a self-supporting substrate having a plurality of spaced-apart needles (spikes or microcapillaries) projecting upwardly from a major surface of the substrate. In a preferred method, metal is deposited onto a porous membrane such that the metal extends into the pores, after which the membrane is dissolved. 9 figures.

  2. Transition Metal Switchable Mirror

    ScienceCinema

    None

    2017-12-29

    The switchable-mirrors technology was developed by Tom Richardson and Jonathan Slack of Berkeley Lab's Environmental Energy Technologies Division. By using transition metals rather than the rare earth metals used in the first metal-hydride switchable mirrors, Richardson and Slack were able to lower the cost and simplify the manufacturing process. Energy performance is improved as well, because the new windows can reflect or transmit both visible and infrared light. Besides windows for offices and homes, possible applications include automobile sunroofs, signs and displays, aircraft windows, and spacecraft. More information at: http://windows.lbl.gov/materials/chromogenics/default.htm

  3. Crystal Violet Lactone Salicylaldehyde Hydrazone Zn(II) Complex: a Reversible Photochromic Material both in Solution and in Solid Matrix

    PubMed Central

    Li, Kai; Li, Yuanyuan; Tao, Jing; Liu, Lu; Wang, Lili; Hou, Hongwei; Tong, Aijun

    2015-01-01

    Crystal violet lactone (CVL) is a classic halochromic dye which has been widely used as chromogenic reagent in thermochromic and piezochromic systems. In this work, a very first example of CVL-based reversible photochromic compound was developed, which showed distinct color change upon UV-visible light irradiation both in solution and in solid matrix. Moreover, metal complex of CVL salicylaldehyde hydrozone was facilely synthesized, exhibiting reversible photochromic properties with good fatigue resistance. It was served as promising solid material for photo-patterning. PMID:26412101

  4. Azocalix[4]arene strapped calix[4]pyrrole: a confirmable fluoride sensor.

    PubMed

    Thiampanya, Preecha; Muangsin, Nongnuj; Pulpoka, Buncha

    2012-08-17

    A new chromogenic fluoride sensor based on 1,3-di-p-nitrophenylazocalix[4]arene-calix[4]pyrrole (1) was designed and synthesized. The color of the solution of probe 1 changed upon the addition of any F(-), CH(3)CO(2)(-), PhCO(2)(-), and H(2)PO(4)(-) ions. However, from these ions the highly specific sensing of F(-) is achieved by the addition of Ca(2+) which leads to a color change from light sky blue (of 1·F(-)) back to the original light orange color of 1.

  5. Squarylium-based chromogenic anion sensors.

    PubMed

    Lee, Eun-Mi; Gwon, Seon-Yeong; Son, Young-A; Kim, Sung-Hoon

    2012-09-01

    A squarylium (SQ) dye was synthesized by the reaction between squaric acid and 2,3,3-trimethylindolenine and its anion sensing properties were investigated using absorption and emission spectroscopy. This chemosensor exhibited high selectivity for CN(-) as compared with F(-), CH(3)CO(2)(-), Br(-), H(2)PO(4)(-), Cl(-), and NO(3)(-) in acetonitrile, which was attributed to the formation of a 1:1 squarylium:CN(-) coordination complex, the formation of which was supported by the calculated geometry of the complex. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Transition Metal Switchable Mirror

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-08-21

    The switchable-mirrors technology was developed by Tom Richardson and Jonathan Slack of Berkeley Lab's Environmental Energy Technologies Division. By using transition metals rather than the rare earth metals used in the first metal-hydride switchable mirrors, Richardson and Slack were able to lower the cost and simplify the manufacturing process. Energy performance is improved as well, because the new windows can reflect or transmit both visible and infrared light. Besides windows for offices and homes, possible applications include automobile sunroofs, signs and displays, aircraft windows, and spacecraft. More information at: http://windows.lbl.gov/materials/chromogenics/default.htm

  7. Surface control alloy substrates and methods of manufacture therefor

    DOEpatents

    Fritzemeier, Leslie G.; Li, Qi; Rupich, Martin W.; Thompson, Elliott D.; Siegal, Edward J.; Thieme, Cornelis Leo Hans; Annavarapu, Suresh; Arendt, Paul N.; Foltyn, Stephen R.

    2004-05-04

    Methods and articles for controlling the surface of an alloy substrate for deposition of an epitaxial layer. The invention includes the use of an intermediate layer to stabilize the substrate surface against oxidation for subsequent deposition of an epitaxial layer.

  8. Method of depositing a high-emissivity layer

    DOEpatents

    Wickersham, Charles E.; Foster, Ellis L.

    1983-01-01

    A method of depositing a high-emissivity layer on a substrate comprising RF sputter deposition of a carbide-containing target in an atmosphere of a hydrocarbon gas and a noble gas. As the carbide is deposited on the substrate the hydrocarbon gas decomposes to hydrogen and carbon. The carbon deposits on the target and substrate causing a carbide/carbon composition gradient to form on the substrate. At a sufficiently high partial pressure of hydrocarbon gas, a film of high-emissivity pure carbon will eventually form over the substrate.

  9. Fabrication of high temperature superconductors

    DOEpatents

    Balachandran, Uthamalingam; Dorris, Stephen E.; Ma, Beihai; Li, Meiya

    2003-06-17

    A method of forming a biaxially aligned superconductor on a non-biaxially aligned substrate substantially chemically inert to the biaxially aligned superconductor comprising is disclosed. A non-biaxially aligned substrate chemically inert to the superconductor is provided and a biaxially aligned superconductor material is deposited directly on the non-biaxially aligned substrate. A method forming a plume of superconductor material and contacting the plume and the non-biaxially aligned substrate at an angle greater than 0.degree. and less than 90.degree. to deposit a biaxially aligned superconductor on the non-biaxially aligned substrate is also disclosed. Various superconductors and substrates are illustrated.

  10. Methods of forming CIGS films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mansfield, Lorelle; Ramanathan, Kannan

    2017-09-19

    Methods for forming CIGS films are provided. According to an aspect of the invention, a method of forming a CIGS film includes a precursor step, which includes simultaneously evaporating Cu, In, Ga, Se, and Sb onto a substrate. The Se is incident on the substrate at a rate of at least 20 .ANG./s. The method also includes a selenization step, which includes evaporating Se over the substrate after the precursor step.

  11. Methods of Antimicrobial Coating of Diverse Materials

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Holtsnider, John T.; Kliestik, Helen

    2011-01-01

    Methods of coating diverse substrate materials with antimicrobial agents have been developed. Originally intended to reduce health risks to astronauts posed by pathogenic microorganisms that can grow on surfaces in spacecraft, these methods could also be used on Earth for example, to ensure sterility of surgical inserts and other medical equipment. The methods involve, generally, chemical preparation of substrate surfaces to enable attachment of antimicrobial molecules to the substrate surfaces via covalent bonds. Substrate materials that have been treated successfully include aluminum, glass, a corrosion-resistant nickel alloy, stainless steel, titanium, and poly(tetrafluoroethylene). Antimicrobial agents that have been successfully immobilized include antibiotics, enzymes, bacteriocins, bactericides, and fungicides. A variety of linkage chem istries were employed. Activity of antimicrobial coatings against gram-positive bacteria, gram-negative bacteria, and fungi was demonstrated. Results of investigations indicate that the most suitable combination of antimicrobial agent, substrate, and coating method depends upon the intended application.

  12. Method of accurate thickness measurement of boron carbide coating on copper foil

    DOEpatents

    Lacy, Jeffrey L.; Regmi, Murari

    2017-11-07

    A method is disclosed of measuring the thickness of a thin coating on a substrate comprising dissolving the coating and substrate in a reagent and using the post-dissolution concentration of the coating in the reagent to calculate an effective thickness of the coating. The preferred method includes measuring non-conducting films on flexible and rough substrates, but other kinds of thin films can be measure by matching a reliable film-substrate dissolution technique. One preferred method includes determining the thickness of Boron Carbide films deposited on copper foil. The preferred method uses a standard technique known as inductively coupled plasma optical emission spectroscopy (ICPOES) to measure boron concentration in a liquid sample prepared by dissolving boron carbide films and the Copper substrates, preferably using a chemical etch known as ceric ammonium nitrate (CAN). Measured boron concentration values can then be calculated.

  13. Fluorine compounds for doping conductive oxide thin films

    DOEpatents

    Gessert, Tim; Li, Xiaonan; Barnes, Teresa M; Torres, Jr., Robert; Wyse, Carrie L

    2013-04-23

    Methods of forming a conductive fluorine-doped metal oxide layer on a substrate by chemical vapor deposition are described. The methods may include heating the substrate in a processing chamber, and introducing a metal-containing precursor and a fluorine-containing precursor to the processing chamber. The methods may also include adding an oxygen-containing precursor to the processing chamber. The precursors are reacted to deposit the fluorine-doped metal oxide layer on the substrate. Methods may also include forming the conductive fluorine-doped metal oxide layer by plasma-assisted chemical vapor deposition. These methods may include providing the substrate in a processing chamber, and introducing a metal-containing precursor, and a fluorine-containing precursor to the processing chamber. A plasma may be formed that includes species from the metal-containing precursor and the fluorine-containing precursor. The species may react to deposit the fluorine-doped metal oxide layer on the substrate.

  14. Apparatus and method for rapid cooling of large area substrates in vacuum

    DOEpatents

    Barth, Kurt L.; Enzenroth, Robert A.; Sampath, Walajabad S.

    2012-11-06

    The present invention is directed to an apparatus and method for rapid cooling of a large substrate in a vacuum environment. A first cooled plate is brought into close proximity with one surface of a flat substrate. The spatial volume between the first cooling plate and the substrate is sealed and brought to a higher pressure than the surrounding vacuum level to increase the cooling efficiency. A second cooled plate is brought into close proximity with the opposite surface of the flat substrate. A second spatial volume between the second cooling plate and the substrate is sealed and the gas pressure is equalized to the gas pressure in the first spatial volume. The equalization of the gas pressure on both sides of the flat substrate eliminates deflection of the substrate and bending stress in the substrate.

  15. Method of creating a controlled interior surface configuration of passages within a substrate

    DOEpatents

    Dembowski, Peter V.; Schilke, Peter W.

    1983-01-01

    A method of creating a controlled interior surface configuration of passages within a substrate, particularly cooling passages of nozzles or buckets of a gas turbine, involves the hot isostatic pressing of a leachable passage insert whose surface carries the female image of the desired interior surface configuration inside the substrate followed by leaching of the insert from the substrate.

  16. Method of deposition of silicon carbide layers on substrates

    DOEpatents

    Angelini, P.; DeVore, C.E.; Lackey, W.J.; Blanco, R.E.; Stinton, D.P.

    1982-03-19

    A method for direct chemical vapor deposition of silicon carbide to substrates, especially nuclear waste particles, is provided by the thermal decomposition of methylsilane at 800 to 1050/sup 0/C when the substrates have been confined within a suitable coating environment.

  17. Spectrophotometric techniques to determine tranexamic acid: Kinetic studies using ninhydrin and direct measuring using ferric chloride

    NASA Astrophysics Data System (ADS)

    Arayne, M. Saeed; Sultana, Najma; Siddiqui, Farhan Ahmed; Mirza, Agha Zeeshan; Zuberi, M. Hashim

    2008-11-01

    Two simple and sensitive spectrophotometric methods in ultraviolet and visible region are described for the determination of tranexamic acid in pure form and pharmaceutical preparations. The first method is based on the reaction of the drug with ninhydrin at boiling temperature and by measuring the increase in absorbance at 575 nm as a function of time. The initial rate, rate constant and fixed time (120 min) procedures were used for constructing the calibration graphs to determine the concentration of the drug, which showed a linear response over the concentration range 16-37 μg mL -1 with correlation coefficient " r" 0.9997, 0.996, 0.9999, LOQ 6.968, 7.138, 2.462 μgmL -1 and LOD 2.090, 2.141 and 0.739 μgmL -1, respectively. In second method tranexamic acid was reacted with ferric chloride solution, yellowish orange colored chromogen showed λ max at 375 nm showing linearity in the concentration range of 50-800 μg mL -1 with correlation coefficient " r" 0.9997, LOQ 6.227 μgmL -1 and LOD 1.868 μgmL -1. The variables affecting the development of the color were optimized and the developed methods were validated statistically and through recovery studies. These results were also verified by IR and NMR spectroscopy. The proposed methods have been successfully applied to the determination of tranexamic acid in commercial pharmaceutical formulation.

  18. In situ optical diagnostic for monitoring or control of sodium diffusion in photovoltaics manufacturing

    DOEpatents

    Li, Jian; Levi, Dean; Contreras, Miguel; Glynn, Stephen

    2015-09-15

    A method of fabricating a photovoltaic device 100, includes the steps of providing a glass substrate 102, depositing a molybdenum layer 104 on a surface of the glass substrate, directing light through the glass substrate to the near-substrate region of the molybdenum layer 206, detecting an optical property of the near-substrate region of the molybdenum layer after interaction with the incident light 208 and determining a density of the near-substrate region of the molybdenum layer from the detected optical property 210. A molybdenum deposition parameter may be controlled based upon the determined density of the near-substrate region of the molybdenum layer 218. A non-contact method measures a density of the near-substrate region of a molybdenum layer and a deposition chamber 300.

  19. Systems and Methods for Implementing Robust Carbon Nanotube-Based Field Emitters

    NASA Technical Reports Server (NTRS)

    Kristof, Valerie (Inventor); Manohara, Harish (Inventor); Toda, Risaku (Inventor)

    2015-01-01

    Systems and methods in accordance with embodiments of the invention implement carbon nanotube-based field emitters. In one embodiment, a method of fabricating a carbon nanotube field emitter includes: patterning a substrate with a catalyst, where the substrate has thereon disposed a diffusion barrier layer; growing a plurality of carbon nanotubes on at least a portion of the patterned catalyst; and heating the substrate to an extent where it begins to soften such that at least a portion of at least one carbon nanotube becomes enveloped by the softened substrate.

  20. Superconducting articles of manufacture and method of producing same

    DOEpatents

    Newkirk, Lawrence R.; Valencia, Flavio A.

    1980-01-01

    Bulk coatings of Nb.sub.3 Ge with high superconducting transition temperatures bonded to metallic substrates and a chemical vapor deposition method for producing such coatings on metallic substrates are disclosed. In accordance with the method, a Nb.sub.3 Ge coating having a transition temperature in excess of 21.5 K may be tightly bonded to a copper substrate.

  1. Substrate comprising a nanometer-scale projection array

    DOEpatents

    Cui, Yi; Zhu, Jia; Hsu, Ching-Mei; Connor, Stephen T; Yu, Zongfu; Fan, Shanhui; Burkhard, George

    2012-11-27

    A method for forming a substrate comprising nanometer-scale pillars or cones that project from the surface of the substrate is disclosed. The method enables control over physical characteristics of the projections including diameter, sidewall angle, and tip shape. The method further enables control over the arrangement of the projections including characteristics such as center-to-center spacing and separation distance.

  2. Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture

    DOEpatents

    Lassahn, Gordon D.; Lancaster, Gregory D.; Apel, William A.; Thompson, Vicki S.

    2013-01-08

    Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture are described. According to one embodiment, an image portion identification method includes accessing data regarding an image depicting a plurality of biological substrates corresponding to at least one biological sample and indicating presence of at least one biological indicator within the biological sample and, using processing circuitry, automatically identifying a portion of the image depicting one of the biological substrates but not others of the biological substrates.

  3. Buffer layers on biaxially textured metal substrates

    DOEpatents

    Shoup, Shara S.; Paranthamam, Mariappan; Beach, David B.; Kroeger, Donald M.; Goyal, Amit

    2001-01-01

    A method is disclosed for forming a biaxially textured buffer layer on a biaxially oriented metal substrate by using a sol-gel coating technique followed by pyrolyzing/annealing in a reducing atmosphere. This method is advantageous for providing substrates for depositing electronically active materials thereon.

  4. Method for forming a nano-textured substrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeong, Sangmoo; Hu, Liangbing; Cui, Yi

    A method for forming a nano-textured surface on a substrate is disclosed. An illustrative embodiment of the present invention comprises dispensing of a nanoparticle ink of nanoparticles and solvent onto the surface of a substrate, distributing the ink to form substantially uniform, liquid nascent layer of the ink, and enabling the solvent to evaporate from the nanoparticle ink thereby inducing the nanoparticles to assemble into an texture layer. Methods in accordance with the present invention enable rapid formation of large-area substrates having a nano-textured surface. Embodiments of the present invention are well suited for texturing substrates using high-speed, large scale,more » roll-to-roll coating equipment, such as that used in office product, film coating, and flexible packaging applications. Further, embodiments of the present invention are well suited for use with rigid or flexible substrates.« less

  5. A High-yield Two-step Transfer Printing Method for Large-scale Fabrication of Organic Single-crystal Devices on Arbitrary Substrates

    PubMed Central

    Deng, Wei; Zhang, Xiujuan; Pan, Huanhuan; Shang, Qixun; Wang, Jincheng; Zhang, Xiaohong; Zhang, Xiwei; Jie, Jiansheng

    2014-01-01

    Single-crystal organic nanostructures show promising applications in flexible and stretchable electronics, while their applications are impeded by the large incompatibility with the well-developed photolithography techniques. Here we report a novel two-step transfer printing (TTP) method for the construction of organic nanowires (NWs) based devices onto arbitrary substrates. Copper phthalocyanine (CuPc) NWs are first transfer-printed from the growth substrate to the desired receiver substrate by contact-printing (CP) method, and then electrode arrays are transfer-printed onto the resulting receiver substrate by etching-assisted transfer printing (ETP) method. By utilizing a thin copper (Cu) layer as sacrificial layer, microelectrodes fabricated on it via photolithography could be readily transferred to diverse conventional or non-conventional substrates that are not easily accessible before with a high transfer yield of near 100%. The ETP method also exhibits an extremely high flexibility; various electrodes such as Au, Ti, and Al etc. can be transferred, and almost all types of organic devices, such as resistors, Schottky diodes, and field-effect transistors (FETs), can be constructed on planar or complex curvilinear substrates. Significantly, these devices can function properly and exhibit closed or even superior performance than the device counterparts fabricated by conventional approach. PMID:24942458

  6. Method for preparing ultraflat, atomically perfect areas on large regions of a crystal surface by heteroepitaxy deposition

    DOEpatents

    El Gabaly, Farid; Schmid, Andreas K.

    2013-03-19

    A novel method of forming large atomically flat areas is described in which a crystalline substrate having a stepped surface is exposed to a vapor of another material to deposit a material onto the substrate, which material under appropriate conditions self arranges to form 3D islands across the substrate surface. These islands are atomically flat at their top surface, and conform to the stepped surface of the substrate below at the island-substrate interface. Thereafter, the deposited materials are etched away, in the etch process the atomically flat surface areas of the islands transferred to the underlying substrate. Thereafter the substrate may be cleaned and annealed to remove any remaining unwanted contaminants, and eliminate any residual defects that may have remained in the substrate surface as a result of pre-existing imperfections of the substrate.

  7. Surface Treatment of Plastic Substrates using Atomic Hydrogen Generated on Heated Tungsten Wire at Low Temperatures

    NASA Astrophysics Data System (ADS)

    Heya, Akira; Matsuo, Naoto

    2007-06-01

    The surface properties of a plastic substrate were changed by a novel surface treatment called atomic hydrogen annealing (AHA). In this method, a plastic substrate was exposed to atomic hydrogen generated by cracking hydrogen molecules on heated tungsten wire. For the substrate, surface roughness was increased and halogen elements (F and Cl) were selectively etched by AHA. AHA was useful for pretreatment before film deposition on a plastic substrate because the changes in surface state relate to adhesion improvement. It is concluded that this method is a promising technique for preparing high-performance plastic substrates at low temperatures.

  8. An improved method to unravel phosphoacceptors in Ser/Thr protein kinase-phosphorylated substrates.

    PubMed

    Molle, Virginie; Leiba, Jade; Zanella-Cléon, Isabelle; Becchi, Michel; Kremer, Laurent

    2010-11-01

    Identification of the phosphorylated residues of bacterial Ser/Thr protein kinase (STPK) substrates still represents a challenging task. Herein, we present a new strategy allowing the rapid determination of phosphoacceptors in kinase substrates, essentially based on the dual expression of the kinase with its substrate in the surrogate E. coli, followed by MS analysis in a single-step procedure. The performance of this strategy is illustrated using two distinct proteins from Mycobacterium tuberculosis as model substrates, the GroEL2 and HspX chaperones. A comparative analysis with a standard method that includes mass spectrometry analysis of in vitro phosphorylated substrates is also addressed.

  9. X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface

    NASA Technical Reports Server (NTRS)

    Wurth, Laura; Evans, Kurt; Weber, Bart; Headrick, Sarah

    2005-01-01

    With environmental regulations limiting the use of volatile organic compounds, low-vapor pressure solvents have replaced traditional degreasing solvents for bond substrate preparation. When used to clean and prepare porous bond substrates such as phenolic composites, low vapor pressure solvents can penetrate deep into substrate pore networks and remain there for extended periods. Trapped solvents can interact with applied adhesives either prior to or during cure, potentially compromising bond properties. Currently, methods for characterizing solvent time-depth profiles in bond substrates are limited to bulk gravimetric or sectioning techniques. While sectioning techniques such as microtome allow construction of solvent depth profiles, their depth resolution and reliability are limited by substrate type. Sectioning techniques are particularly limited near the adhesive-substrate interface where depth resolution is further limited by adhesive-substrate hardness and, in the case of a partially cured adhesive, mechanical properties differences. Additionally, sectioning techniques cannot provide information about lateral solvent diffusion. Cross-section component mapping is an alternative method for measuring solvent migration in porous substrates that eliminates the issues associated with sectioning techniques. With cross-section mapping, the solvent-wiped substrate is sectioned perpendicular rather than parallel to the wiped surface, and the sectioned surface is analyzed for the solvent or solvent components of interest using a two-dimensional mapping or imaging technique. Solvent mapping can be performed using either direct or indirect methods. With a direct method, one or more solvent components are mapped using red or Raman spectroscopy together with a moveable sample stage and/or focal plane array detector. With an indirect method, an elemental "tag" not present in the substrate is added to the solvent before the substrate is wiped. Following cross sectioning, the tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.

  10. Selective etching of silicon carbide films

    DOEpatents

    Gao, Di; Howe, Roger T.; Maboudian, Roya

    2006-12-19

    A method of etching silicon carbide using a nonmetallic mask layer. The method includes providing a silicon carbide substrate; forming a non-metallic mask layer by applying a layer of material on the substrate; patterning the mask layer to expose underlying areas of the substrate; and etching the underlying areas of the substrate with a plasma at a first rate, while etching the mask layer at a rate lower than the first rate.

  11. Method for making an aluminum or copper substrate panel for selective absorption of solar energy

    NASA Technical Reports Server (NTRS)

    Roberts, M. L.; Sharpe, M. H.; Krupnick, A. C. (Inventor)

    1978-01-01

    A panel is described for selectively absorbing solar energy comprising an aluminum substrate. A zinc layer was covered by a layer of nickel and an outer layer of solar energy absorbing nickel oxide or a copper substrate with a nickel layer. A layer of solar energy absorbing nickel oxide distal from the copper substrate was included. A method for making these panels is disclosed.

  12. Method for materials deposition by ablation transfer processing

    DOEpatents

    Weiner, Kurt H.

    1996-01-01

    A method in which a thin layer of semiconducting, insulating, or metallic material is transferred by ablation from a source substrate, coated uniformly with a thin layer of said material, to a target substrate, where said material is desired, with a pulsed, high intensity, patternable beam of energy. The use of a patternable beam allows area-selective ablation from the source substrate resulting in additive deposition of the material onto the target substrate which may require a very low percentage of the area to be covered. Since material is placed only where it is required, material waste can be minimized by reusing the source substrate for depositions on multiple target substrates. Due to the use of a pulsed, high intensity energy source the target substrate remains at low temperature during the process, and thus low-temperature, low cost transparent glass or plastic can be used as the target substrate. The method can be carried out atmospheric pressures and at room temperatures, thus eliminating vacuum systems normally required in materials deposition processes. This invention has particular application in the flat panel display industry, as well as minimizing materials waste and associated costs.

  13. Method for preparing high temperature superconductor

    DOEpatents

    Balachandran, Uthamalingam; Chudzik, Michael P.

    2002-01-01

    A method of depositing a biaxially textured metal oxide on a substrate defining a plane in which metal oxide atoms are vaporized from a source to form a plume of metal oxide atoms. Atoms in the plume disposed at a selected angle in a predetermined range of angles to the plane of the substrate are allowed to contact the substrate while preventing atoms outside a selected angle from reaching the substrate. The preferred range of angles is 40.degree.-70.degree. and the preferred angle is 60.degree..+-.5.degree.. A moving substrate is disclosed.

  14. Narrow energy band gap gallium arsenide nitride semi-conductors and an ion-cut-synthesis method for producing the same

    DOEpatents

    Weng, Xiaojun; Goldman, Rachel S.

    2006-06-06

    A method for forming a semi-conductor material is provided that comprises forming a donor substrate constructed of GaAs, providing a receiver substrate, implanting nitrogen into the donor substrate to form an implanted layer comprising GaAs and nitrogen. The implanted layer is bonded to the receiver substrate and annealed to form GaAsN and nitrogen micro-blisters in the implanted layer. The micro-blisters allow the implanted layer to be cleaved from the donor substrate.

  15. Method of fabricating high-density hermetic electrical feedthroughs

    DOEpatents

    Shah, Kedar G.; Pannu, Satinderpall S.; Delima, Terri L.

    2015-06-02

    A method of fabricating electrical feedthroughs selectively removes substrate material from a first side of an electrically conductive substrate (e.g. a bio-compatible metal) to form an array of electrically conductive posts in a substrate cavity. An electrically insulating material (e.g. a bio-compatible sealing glass) is then flowed to fill the substrate cavity and surround each post, and solidified. The solidified insulating material is then exposed from an opposite second side of the substrate so that each post is electrically isolated from each other as well as the bulk substrate. In this manner a hermetic electrically conductive feedthrough construction is formed having an array of electrical feedthroughs extending between the first and second sides of the substrate from which it was formed.

  16. Pin-deposition of conductive inks for microelectrodes and contact via filling

    DOEpatents

    Davidson, J. Courtney; Krulevitch, Peter A.; Maghribi, Mariam N.; Hamilton, Julie K.; Benett, William J.; Tovar, Armando R.

    2006-05-02

    A method of metalization of an integrated microsystem. The method comprises providing a substrate and applying a conductive material to the substrate by taking up small aliquots of conductive material and releasing the conductive material onto the substrate to produce a circuit component.

  17. Method of deposition of silicon carbide layers on substrates and product

    DOEpatents

    Angelini, Peter; DeVore, Charles E.; Lackey, Walter J.; Blanco, Raymond E.; Stinton, David P.

    1984-01-01

    A method for direct chemical vapor deposition of silicon carbide to substrates, especially nuclear waste particles, is provided by the thermal decomposition of methylsilane at about 800.degree. C. to 1050.degree. C. when the substrates have been confined within a suitable coating environment.

  18. Mechanism of bonding and debonding using surface activated bonding method with Si intermediate layer

    NASA Astrophysics Data System (ADS)

    Takeuchi, Kai; Fujino, Masahisa; Matsumoto, Yoshiie; Suga, Tadatomo

    2018-04-01

    Techniques of handling thin and fragile substrates in a high-temperature process are highly required for the fabrication of semiconductor devices including thin film transistors (TFTs). In our previous study, we proposed applying the surface activated bonding (SAB) method using Si intermediate layers to the bonding and debonding of glass substrates. The SAB method has successfully bonded glass substrates at room temperature, and the substrates have been debonded after heating at 450 °C, in which TFTs are fabricated on thin glass substrates for LC display devices. In this study, we conducted the bonding and debonding of Si and glass in order to understand the mechanism in the proposed process. Si substrates are also successfully bonded to glass substrates at room temperature and debonded after heating at 450 °C using the proposed bonding process. By the composition analysis of bonding interfaces, it is clarified that the absorbed water on the glass forms interfacial voids and cause the decrease in bond strength.

  19. Method of forming catalyst layer by single step infiltration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerdes, Kirk; Lee, Shiwoo; Dowd, Regis

    Provided herein is a method for electrocatalyst infiltration of a porous substrate, of particular use for preparation of a cathode for a solid oxide fuel cell. The method generally comprises preparing an electrocatalyst infiltrate solution comprising an electrocatalyst, surfactant, chelating agent, and a solvent; pretreating a porous mixed ionic-electric conductive substrate; and applying the electrocatalyst infiltration solution to the porous mixed ionic-electric conductive substrate.

  20. Methods of preparing flexible photovoltaic devices using epitaxial liftoff, and preserving the integrity of growth substrates used in epitaxial growth

    DOEpatents

    Forrest, Stephen R; Zimmerman, Jeramy; Lee, Kyusang; Shiu, Kuen-Ting

    2015-01-06

    There is disclosed methods of making photosensitive devices, such as flexible photovoltaic (PV) devices, through the use of epitaxial liftoff. Also described herein are methods of preparing flexible PV devices comprising a structure having a growth substrate, wherein the selective etching of protective layers yields a smooth growth substrate that us suitable for reuse.

  1. Methods of preparing flexible photovoltaic devices using epitaxial liftoff, and preserving the integrity of growth substrates used in epitaxial growth

    DOEpatents

    Forrest, Stephen R; Zimmerman, Jeramy; Lee, Kyusang; Shiu, Kuen-Ting

    2013-02-19

    There is disclosed methods of making photosensitive devices, such as flexible photovoltaic (PV) devices, through the use of epitaxial liftoff. Also described herein are methods of preparing flexible PV devices comprising a structure having a growth substrate, wherein the selective etching of protective layers yields a smooth growth substrate that us suitable for reuse.

  2. Superconducting articles, and methods for forming and using same

    DOEpatents

    Knoll, Allan Robert [Guilderland, NY; Lenseth, Kenneth Patrick [Wynantskill, NY

    2007-01-09

    A superconducting tape is disclosed, including a substrate having a first surface and a second surface opposite the first surface, the substrate including a plurality of indicia provided on the first surface spaced apart along a length of the substrate; and a superconductor layer overlying the second surface. Also disclosed are components incorporating superconducting tapes, methods for manufacturing same, and methods for using same.

  3. Fluorinated precursors of superconducting ceramics, and methods of making the same

    DOEpatents

    Wiesmann, Harold; Solovyov, Vyacheslav

    2014-02-18

    This invention provides a method of making a fluorinated precursor of a superconducting ceramic. The method comprises providing a solution comprising a rare earth salt, an alkaline earth metal salt and a copper salt; spraying the solution onto a substrate to provide a film-covered substrate; and heating the film-covered substrate in an atmosphere containing fluorinated gas to provide the fluorinated precursor.

  4. Fluorinated precursors of superconducting ceramics, and methods of making the same

    DOEpatents

    Wiesmann, Harold [Stony Brook, NY; Solovyov, Vyacheslav [Rocky Point, NY

    2008-04-22

    This invention provides a method of making a fluorinated precursor of a superconducting ceramic. The method comprises providing a solution comprising a rare earth salt, an alkaline earth metal salt and a copper salt; spraying the solution onto a substrate to provide a film-covered substrate; and heating the film-covered substrate in an atmosphere containing fluorinated gas to provide the fluorinated precursor.

  5. Fluorinated precursors of superconducting ceramics, and methods of making the same

    DOEpatents

    Wiesmann, Harold [Stony Brook, NY; Solovyov, Vyacheslav [Rocky Point, NY

    2012-07-10

    This invention provides a method of making a fluorinated precursor of a superconducting ceramic. The method comprises providing a solution comprising a rare earth salt, an alkaline earth metal salt and a copper salt; spraying the solution onto a substrate to provide a film-covered substrate; and heating the film-covered substrate in an atmosphere containing fluorinated gas to provide the fluorinated precursor.

  6. Wet-chemical systems and methods for producing black silicon substrates

    DOEpatents

    Yost, Vernon; Yuan, Hao-Chih; Page, Matthew

    2015-05-19

    A wet-chemical method of producing a black silicon substrate. The method comprising soaking single crystalline silicon wafers in a predetermined volume of a diluted inorganic compound solution. The substrate is combined with an etchant solution that forms a uniform noble metal nanoparticle induced Black Etch of the silicon wafer, resulting in a nanoparticle that is kinetically stabilized. The method comprising combining with an etchant solution having equal volumes acetonitrile/acetic acid:hydrofluoric acid:hydrogen peroxide.

  7. Differential homogeneous immunosensor device

    DOEpatents

    Malmros, Mark K.; Gulbinski, III, Julian

    1990-04-10

    There is provided a novel method of testing for the presence of an analyte in a fluid suspected of containing the same. In this method, in the presence of the analyte, a substance capable of modifying certain characteristics of the substrate is bound to the substrate and the change in these qualities is measured. While the method may be modified for carrying out quantitative differential analyses, it eliminates the need for washing analyte from the substrate which is characteristic of prior art methods.

  8. Direct Isolation of Candida spp. from Blood Cultures on the Chromogenic Medium CHROMagar Candida

    PubMed Central

    Horvath, Lynn L.; Hospenthal, Duane R.; Murray, Clinton K.; Dooley, David P.

    2003-01-01

    CHROMagar Candida is a selective and differential chromogenic medium that has been shown to be useful for identification of Candida albicans, Candida krusei, Candida tropicalis, and perhaps Candida glabrata. Colony morphology and color have been well defined when CHROMagar Candida has been used to isolate yeast directly from clinical specimens, including stool, urine, respiratory, vaginal, oropharyngeal, and esophageal sources. Direct isolation of yeast on CHROMagar Candida from blood cultures has not been evaluated. We evaluated whether the color and colony characteristics produced by Candida spp. on CHROMagar Candida were altered when yeasts were isolated directly from blood cultures. Fifty clinical isolates of Candida were inoculated into aerobic and anaerobic blood culture bottles and incubated at 35°C in an automated blood culture system. When growth was detected, an aliquot was removed and plated onto CHROMagar Candida. As a control, CHROMagar Candida plates were inoculated with the same isolate of yeast grown on Sabouraud dextrose agar simultaneously. No significant difference was detected in color or colony morphology between the blood and control isolates in any of the tested organisms. All C. albicans (n = 12), C. tropicalis (n = 12), C. glabrata (n = 9), and C. krusei (n = 5) isolates exhibited the expected species-specific colony characteristics and color, whether isolated directly from blood or from control cultures. CHROMagar Candida can be reliably used for direct isolation of yeast from blood cultures. Direct isolation could allow mycology laboratories to more rapidly identify Candida spp., enable clinicians to more quickly make antifungal agent selections, and potentially decrease patient morbidity and mortality. PMID:12791890

  9. Screening test recommendations for methicillin-resistant Staphylococcus aureus surveillance practices: A cost-minimization analysis.

    PubMed

    Whittington, Melanie D; Curtis, Donna J; Atherly, Adam J; Bradley, Cathy J; Lindrooth, Richard C; Campbell, Jonathan D

    2017-07-01

    To mitigate methicillin-resistant Staphylococcus aureus (MRSA) infections, intensive care units (ICUs) conduct surveillance through screening patients upon admission followed by adhering to isolation precautions. Two surveillance approaches commonly implemented are universal preemptive isolation and targeted isolation of only MRSA-positive patients. Decision analysis was used to calculate the total cost of universal preemptive isolation and targeted isolation. The screening test used as part of the surveillance practice was varied to identify which screening test minimized inappropriate and total costs. A probabilistic sensitivity analysis was conducted to evaluate the range of total costs resulting from variation in inputs. The total cost of the universal preemptive isolation surveillance practice was minimized when a polymerase chain reaction screening test was used ($82.51 per patient). Costs were $207.60 more per patient when a conventional culture was used due to the longer turnaround time and thus higher isolation costs. The total cost of the targeted isolation surveillance practice was minimized when chromogenic agar 24-hour testing was used ($8.54 per patient). Costs were $22.41 more per patient when polymerase chain reaction was used. For ICUs that preemptively isolate all patients, the use of a polymerase chain reaction screening test is recommended because it can minimize total costs by reducing inappropriate isolation costs. For ICUs that only isolate MRSA-positive patients, the use of chromogenic agar 24-hour testing is recommended to minimize total costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Spinel-structured metal oxide on a substrate and method of making same by molecular beam epitaxy

    DOEpatents

    Chambers, Scott A.

    2006-02-21

    A method of making a spinel-structured metal oxide on a substrate by molecular beam epitaxy, comprising the step of supplying activated oxygen, a first metal atom flux, and at least one other metal atom flux to the surface of the substrate, wherein the metal atom fluxes are individually controlled at the substrate so as to grow the spinel-structured metal oxide on the substrate and the metal oxide is substantially in a thermodynamically stable state during the growth of the metal oxide. A particular embodiment of the present invention encompasses a method of making a spinel-structured binary ferrite, including Co ferrite, without the need of a post-growth anneal to obtain the desired equilibrium state.

  11. Growth of coincident site lattice matched semiconductor layers and devices on crystalline substrates

    DOEpatents

    Norman, Andrew G; Ptak, Aaron J

    2013-08-13

    Methods of fabricating a semiconductor layer or device and said devices are disclosed. The methods include but are not limited to providing a substrate having a crystalline surface with a known lattice parameter (a). The method further includes growing a crystalline semiconductor layer on the crystalline substrate surface by coincident site lattice matched epitaxy, without any buffer layer between the crystalline semiconductor layer and the crystalline surface of the substrate. The crystalline semiconductor layer will be prepared to have a lattice parameter (a') that is related to the substrate lattice parameter (a). The lattice parameter (a') maybe related to the lattice parameter (a) by a scaling factor derived from a geometric relationship between the respective crystal lattices.

  12. Ammonia release method for depositing metal oxides

    DOEpatents

    Silver, Gary L.; Martin, Frank S.

    1994-12-13

    A method of depositing metal oxides on substrates which is indifferent to the electrochemical properties of the substrates and which comprises forming ammine complexes containing metal ions and thereafter effecting removal of ammonia from the ammine complexes so as to permit slow precipitation and deposition of metal oxide on the substrates.

  13. Method and apparatus for forming conformal SiN.sub.x films

    DOEpatents

    Wang, Qi

    2007-11-27

    A silicon nitride film formation method includes: Heating a substrate to be subjected to film formation to a substrate temperature; heating a wire to a wire temperature; supplying silane, ammonia, and hydrogen gases to the heating member; and forming a silicon nitride film on the substrate.

  14. Rapid detection of multidrug resistant Gram-negative bacilli by Cica-Beta-Test strips.

    PubMed

    Lavigne, J-P; Pfeiffer, C; Vidal, L; Sotto, A

    2011-02-01

    This study aimed to evaluate the sensitivity and specificity of a new system (Cica-Beta-Test, Kanto Chemical, Japan) for rapid detection of AmpC-derepressed, extended-spectrum β-lactamases (ESβL) and metallo-β-lactamases (MβL). Two hundred Multi-Drug Resistant (MDR)-Gram-negative bacilli were studied: 170 Enterobacteriaceae and 30 Gram-negative non-fermentative bacteria. One hundred and eighteen strains produced an ESβL, seven MβL and 75 derepressed cephalosporinases. One drop of substrate was dispensed onto the filter pad of the Cica-Beta-Test strip. The bacterial colonies were spread on the filter pad of strip. The reading was performed after 2 to 15 min: turning chromogenic indicated the positive test. Three tests were used: Cica-Beta I for detection of MDR bacteria; Cica-Beta MβL for detection of MβL-producing bacteria and Cica-Beta CVA, which distinguish ESβL and AmpC-derepressed producers. Results were compared with molecular assays. Cica-Beta-Test I has detected 194 MDR (sensitivity 97%), Cica-Beta-Test MβL has shown the presence of six MβL tested (sensitivity 85.7%). Five strains were non-MβL false positive (specificity 97.3%). Cica-Beta-Test CVA allowed the differentiation of ESβL-producing strains (109/115) and AmpC-derepressed strains (56/67) (sensitivity 94.8%, specificity 83.8%). Because of their epidemic nature, the MDR strains are screened and require strict hygienic measures patients. The simultaneous use of three strips can quickly determine the presence of MDR including ESβL and MβL. Rapid screening of MDR avoids transmission and limits the use of broad-spectrum antibiotics. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  15. Purification, Characterization, and Overexpression of Flavin Reductase Involved in Dibenzothiophene Desulfurization by Rhodococcus erythropolis D-1

    PubMed Central

    Matsubara, Toshiyuki; Ohshiro, Takashi; Nishina, Yoshihiro; Izumi, Yoshikazu

    2001-01-01

    The dibenzothiophene (DBT)-desulfurizing bacterium, Rhodococcus erythropolis D-1, removes sulfur from DBT to form 2-hydroxybiphenyl using four enzymes, DszC, DszA, DszB, and flavin reductase. In this study, we purified and characterized the flavin reductase from R. erythropolis D-1 grown in a medium containing DBT as the sole source of sulfur. It is conceivable that the enzyme is essential for two monooxygenase (DszC and DszA) reactions in vivo. The purified flavin reductase contains no chromogenic cofactors and was found to have a molecular mass of 86 kDa and four identical 22-kDa subunits. The enzyme catalyzed NADH-dependent reduction of flavin mononucleotide (FMN), and the Km values for NADH and FMN were 208 and 10.8 μM, respectively. Flavin adenine dinucleotide was a poor substrate, and NADPH was inert. The enzyme did not catalyze reduction of any nitroaromatic compound. The optimal temperature and optimal pH for enzyme activity were 35°C and 6.0, respectively, and the enzyme retained 30% of its activity after heat treatment at 80°C for 30 min. The N-terminal amino acid sequence of the purified flavin reductase was identical to that of DszD of R. erythropolis IGTS8 (K. A. Gray, O. S. Pogrebinsky, G. T. Mrachko, L. Xi, D. J. Monticello, and C. H. Squires, Nat. Biotechnol. 14:1705–1709, 1996). The flavin reductase gene was amplified with primers designed by using dszD of R. erythropolis IGTS8, and the enzyme was overexpressed in Escherichia coli. The specific activity in crude extracts of the overexpressed strain was about 275-fold that of the wild-type strain. PMID:11229908

  16. Development of an Avirulent Salmonella Surrogate for Modeling Pathogen Behavior in Pre- and Postharvest Environments

    PubMed Central

    de Moraes, Marcos H.; Chapin, Travis K.; Ginn, Amber; Wright, Anita C.; Parker, Kenneth; Hoffman, Carol; Pascual, David W.; Danyluk, Michelle D.

    2016-01-01

    ABSTRACT Recurrent outbreaks of bacterial gastroenteritis linked to the consumption of fresh fruits and vegetables highlight the paucity of understanding of the ecology of Salmonella enterica under crop production and postharvest conditions. These gaps in knowledge are due, at least in part, to the lack of suitable surrogate organisms for studies for which biosafety level 2 is problematic. Therefore, we constructed and validated an avirulent strain of Salmonella enterica serovar Typhimurium. The strain lacks major Salmonella pathogenicity islands SPI-1, SPI-2, SPI-3, SPI-4, and SPI-5 as well as the virulence plasmid pSLT. Deletions and the absence of genomic rearrangements were confirmed by genomic sequencing, and the surrogate behaved like the parental wild-type strain on selective media. A loss-of-function (phoN) selective marker allowed the differentiation of this strain from wild-type strains on a medium containing a chromogenic substrate for alkaline phosphatase. Lack of virulence was confirmed by oral infection of female BALB/c mice. The strain persisted in tomatoes, cantaloupes, leafy greens, and soil with the same kinetics as the parental wild-type and selected outbreak strains, and it reached similar final population levels. The responses of this strain to heat treatment and disinfectants were similar to those of the wild type, supporting its potential as a surrogate for future studies on the ecology and survival of Salmonella in production and processing environments. IMPORTANCE There is significant interest in understanding the ecology of human pathogens in environments outside of their animal hosts, including the crop production environment. However, manipulative field experiments with virulent human pathogens are unlikely to receive regulatory approval due to the obvious risks. Therefore, we constructed an avirulent strain of S. enterica serovar Typhimurium and characterized it extensively. PMID:27129962

  17. Dynamic changes in plasma tissue plasminogen activator, plasminogen activator inhibitor-1 and beta-thromboglobulin content in ischemic stroke.

    PubMed

    Zhuang, Ping; Wo, Da; Xu, Zeng-Guang; Wei, Wei; Mao, Hui-ming

    2015-07-01

    The aim of this paper is to investigate the corresponding variations of plasma tissue plasminogen activator (t-PA) and plasminogen activator inhibitor-1 (PAI-1) activities, and beta-thromboglobulin (β-TG) content in patients during different stages of ischemic stroke. Ischemic stroke is a common disease among aging people and its occurrence is associated with abnormalities in the fibrinolytic system and platelet function. However, few reports focus on the dynamic changes in the plasma fibrinolytic system and β-TG content in patients with ischemic stroke. Patients were divided into three groups: acute, convalescent and chronic. Plasma t-PA and PAI-1 activities were determined by chromogenic substrate analysis and plasma β-TG content was detected by radioimmunoassay. Patients in the acute stage of ischemic stroke had significantly increased levels of t-PA activity and β-TG content, but PAI-1 activity was significantly decreased. Negative correlations were found between plasma t-PA and PAI-1 activities and between plasma t-PA activity and β-TG content in patients with acute ischemic stroke. There were significant differences in plasma t-PA and PAI-1 activities in the aged control group, as well as in the acute, convalescent and chronic groups. It can be speculated that the increased activity of t-PA in patients during the acute stage was the result of compensatory function, and that the increase in plasma β-TG level not only implies the presence of ischemic stroke but is likely a cause of ischemic stroke. During the later stages of ischemic stroke, greater attention is required in monitoring levels of PAI-1. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Plasmid-Encoded Phthalate Catabolic Pathway in Arthrobacter keyseri 12B†

    PubMed Central

    Eaton, Richard W.

    2001-01-01

    Several 2-substituted benzoates (including 2-trifluoromethyl-, 2-chloro-, 2-bromo-, 2-iodo-, 2-nitro-, 2-methoxy-, and 2-acetyl-benzoates) were converted by phthalate-grown Arthrobacter keyseri (formerly Micrococcus sp.) 12B to the corresponding 2-substituted 3,4-dihydroxybenzoates (protocatechuates). Because these products lack a carboxyl group at the 2 position, they were not substrates for the next enzyme of the phthalate catabolic pathway, 3,4-dihydroxyphthalate 2-decarboxylase, and accumulated. When these incubations were carried out in iron-containing minimal medium, the products formed colored chelates. This chromogenic response was subsequently used to identify recombinant Escherichia coli strains carrying genes encoding the responsible enzymes, phthalate 3,4-dioxygenase and 3,4-dihydroxy-3,4-dihydrophthalate dehydrogenase, from the 130-kbp plasmid pRE1 of strain 12B. Beginning with the initially cloned 8.14-kbp PstI fragment of pRE824 as a probe to identify recombinant plasmids carrying overlapping fragments, a DNA segment of 33.5 kbp was cloned from pRE1 on several plasmids and mapped using restriction endonucleases. From these plasmids, the sequence of 26,274 contiguous bp was determined. Sequenced DNA included several genetic units: tnpR, pcm operon, ptr genes, pehA, norA fragment, and pht operon, encoding a transposon resolvase, catabolism of protocatechuate (3,4-dihydroxybenzoate), a putative ATP-binding cassette transporter, a possible phthalate ester hydrolase, a fragment of a norfloxacin resistance-like transporter, and the conversion of phthalate to protocatechuate, respectively. Activities of the eight enzymes involved in the catabolism of phthalate through protocatechuate to pyruvate and oxaloacetate were demonstrated in cells or cell extracts of recombinant E. coli strains. PMID:11371533

  19. Penicillin binding protein 3 of Staphylococcus aureus NCTC 8325-4 binds and activates human plasminogen.

    PubMed

    Kylväjä, Riikka; Ojalehto, Tuomas; Kainulainen, Veera; Virkola, Ritva; Westerlund-Wikström, Benita

    2016-08-04

    Staphylococcus aureus is a versatile pathogen expressing a number of virulence-associated adhesive molecules. In a previous study, we generated in a secretion-competent Escherichia coli strain a library of random FLAG-tag positive (FTP) polypeptides of S. aureus. To identify adhesive proteins and gain additional knowledge on putative virulence factors of S. aureus, we here screened the FTP library against human serum proteins. Staphylococcus aureus NCTC 8325-4, origin of the FTP library, adhered to immobilized plasminogen in vitro. In an enzyme-linked immunoassay a C-terminal part of penicillin binding protein 3 (PBP3), included in the FTP library, bound to immobilized plasminogen. We expressed and purified full-length PBP3 and its C-terminal fragments as recombinant proteins. In a time-resolved fluorometry-based assay the PBP3 polypeptides bound to immobilized plasminogen. The polypeptides enhanced formation of plasmin from plasminogen as analyzed by cleavage of a chromogenic plasmin substrate. The present findings, although preliminary, demonstrate reliably that S. aureus NCTC 8325-4 adheres to immobilized plasminogen in vitro and that the adhesion may be mediated by a C-terminal fragment of the PBP3 protein. The full length PBP3 and the penicillin binding C-terminal domain of PBP3 expressed as recombinant proteins bound plasminogen and activated plasminogen to plasmin. These phenomena were inhibited by the lysine analogue ε-aminocaproic acid suggesting that the binding is mediated by lysine residues. A detailed molecular description of surface molecules enhancing the virulence of S. aureus will aid in understanding of its pathogenicity and help in design of antibacterial drugs in the future.

  20. Role of human amnion-derived mesenchymal stem cells in promoting osteogenic differentiation by influencing p38 MAPK signaling in lipopolysaccharide -induced human bone marrow mesenchymal stem cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yuli; Wu, Hongxia; Shen, Ming

    Periodontitis is a chronic inflammatory disease induced by bacterial pathogens, which not only affect connective tissue attachments but also cause alveolar bone loss. In this study, we investigated the anti-inflammatory effects of Human amnion-derived mesenchymal stem cells (HAMSCs) on human bone marrow mesenchymal stem cells (HBMSCs) under lipopolysaccharide (LPS)-induced inflammatory conditions. Proliferation levels were measured by flow cytometry and immunofluorescence staining of 5-ethynyl-2′-deoxyuridine (EdU). Osteoblastic differentiation and mineralization were investigated using chromogenic alkaline phosphatase activity (ALP) activity substrate assays, Alizarin red S staining, and RT-PCR analysis of HBMSCs osteogenic marker expression. Oxidative stress induced by LPS was investigated by assayingmore » reactive oxygen species (ROS) level and superoxide dismutase (SOD) activity. Here, we demonstrated that HAMSCs increased the proliferation, osteoblastic differentiation, and SOD activity of LPS-induced HBMSCs, and down-regulated the ROS level. Moreover, our results suggested that the activation of p38 MAPK signal transduction pathway is essential for reversing the LPS-induced bone-destructive processes. SB203580, a selective inhibitor of p38 MAPK signaling, significantly suppressed the anti-inflammatory effects in HAMSCs. In conclusion, HAMSCs show a strong potential in treating inflammation-induced bone loss by influencing p38 MAPK signaling. - Highlights: • LPS inhibites osteogenic differentiation in HBMSCs via suppression of p38 MAPK signaling pathway. • HAMSCs promote LPS-induced HBMSCs osteogenic differentiation through p38 MAPK signaling pathway. • HAMSCs reverse LPS-induced oxidative stress in LPS-induced HBMSCs through p38 MAPK signaling pathway.« less

  1. Potentiation of C1-esterase inhibitor by heparin and interactions with C1s protease as assessed by surface plasmon resonance.

    PubMed

    Rajabi, Mohsen; Struble, Evi; Zhou, Zhaohua; Karnaukhova, Elena

    2012-01-01

    Human C1-esterase inhibitor (C1-INH) is a multifunctional plasma protein with a wide range of inhibitory and non-inhibitory properties, mainly recognized as a key down-regulator of the complement and contact cascades. The potentiation of C1-INH by heparin and other glycosaminoglycans (GAGs) regulates a broad spectrum of C1-INH activities in vivo both in normal and disease states. SCOPE OF RESEARCH: We have studied the potentiation of human C1-INH by heparin using Surface Plasmon Resonance (SPR), circular dichroism (CD) and a functional assay. To advance a SPR for multiple-unit interaction studies of C1-INH we have developed a novel (consecutive double capture) approach exploring different immobilization and layout. Our SPR experiments conducted in three different design versions showed marked acceleration in C1-INH interactions with complement protease C1s as a result of potentiation of C1-INH by heparin (from 5- to 11-fold increase of the association rate). Far-UV CD studies suggested that heparin binding did not alter C1-INH secondary structure. Functional assay using chromogenic substrate confirmed that heparin does not affect the amidolytic activity of C1s, but does accelerate its consumption due to C1-INH potentiation. This is the first report that directly demonstrates a significant acceleration of the C1-INH interactions with C1s due to heparin by using a consecutive double capture SPR approach. The results of this study may be useful for further C-INH therapeutic development, ultimately for the enhancement of current C1-INH replacement therapies. Published by Elsevier B.V.

  2. Assessment of the effects of dalteparin on coagulation variables and determination of a treatment schedule for use in cats.

    PubMed

    Schönig, Jette C; Mischke, Reinhard H

    2016-07-01

    OBJECTIVE To determine a treatment protocol for SC administration of dalteparin to cats on the basis of currently available detailed pharmacokinetic data and to assess the effect of SC administration of dalteparin to cats on coagulation variables such as activated partial thromboplastin time (aPTT), thrombin time, and results for thromboelastometry, compared with effects on anti-activated coagulation factor X (anti-Xa) activity. ANIMALS 6 healthy domestic shorthair cats. PROCEDURES Cats received 14 injections of dalteparin (75 anti-Xa U/kg, SC) at 6-hour intervals. Blood samples were collected before and 2 hours after the first and second injections on days 1, 2, and 4. Anti-Xa activity was measured by use of a chromogenic substrate assay, aPTT and thrombin time were measured by use of an automated coagulometer, and viscoelastic measurements were obtained with thromboelastrometry. RESULTS 2 hours after the second injection, the target peak anti-Xa activity range of 0.5 to 1.0 U/mL was achieved in all cats, whereas median trough values remained below this range. Peak anti-Xa activity had only minimal effects on coagulation variables; the maximum median ratio for aPTT (in relationship to the value before the first dalteparin injection) was 1.23. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study indicated that this treatment protocol resulted in reproducible anti-Xa activity in cats that was mostly within the targeted peak range of anti-Xa activity recommended for humans. Treatment in accordance with this protocol may not require routine coagulation monitoring of cats, but this must be confirmed in feline patients.

  3. Thrombostatin FM compounds: direct thrombin inhibitors - mechanism of action in vitro and in vivo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nieman, M T; Burke, F; Warnock, M

    2008-04-29

    Novel pentapeptides called Thrombostatin FM compounds consisting mostly of D-isomers and unusual amino acids were prepared based upon the stable angiotensin converting enzyme breakdown product of bradykinin - RPPGF. These peptides are direct thrombin inhibitors prolonging the thrombin clotting time, activated partial thromboplastin time, and prothrombin time at ≥0.78, 1.6, and 1.6 μm, respectively. They competitively inhibit α-thrombin-induced cleavage of a chromogenic substrate at 4.4--8.2 μm. They do not significantly inhibit plasma kallikrein, factor (F) XIIa, FXIa, FIXa, FVIIa-TF, FXa, plasmin or cathepsin G. One form, FM19 [rOicPaF(p-Me)], blocks α-thrombin-induced calcium flux in fibroblasts with an IC 50 of 6.9more » ± 1.2 μm. FM19 achieved 100% inhibition of threshold α- or γ-thrombin-induced platelet aggregation at 8.4 ± 4.7 μm and 16 ± 4 μm, respectively. The crystal structure of thrombin in complex with FM19 shows that the N-terminal D-Arg retrobinds into the S1 pocket, its second residue Oic interacts with His-57, Tyr-60a and Trp-60d, and its C-terminal p-methyl Phe engages thrombin's aryl binding site composed of Ile-174, Trp-215, and Leu-99. When administered intraperitoneal, intraduodenal, or orally to mice, FM19 prolongs thrombin clotting times and delays carotid artery thrombosis. FM19, a low affinity reversible direct thrombin inhibitor, might be useful as an add-on agent to address an unmet need in platelet inhibition in acute coronary syndromes in diabetics and others who with all current antiplatelet therapy still have reactive platelets.« less

  4. Identification of a Dehydrogenase Required for Lactose Metabolism in Caulobacter crescentus▿ †‡

    PubMed Central

    Arellano, Benjamin H.; Ortiz, Janett D.; Manzano, Janet; Chen, Joseph C.

    2010-01-01

    Caulobacter crescentus, which thrives in freshwater environments with low nutrient levels, serves as a model system for studying bacterial cell cycle regulation and organelle development. We examined its ability to utilize lactose (i) to gain insight into the metabolic capacities of oligotrophic bacteria and (ii) to obtain an additional genetic tool for studying this model organism, aiming to eliminate the basal enzymatic activity that hydrolyzes the chromogenic substrate 5-bromo-4-chloro-3-indolyl-β-d-galactopyranoside (X-gal). Using a previously isolated transposon mutant, we identified a gene, lacA, that is required for growth on lactose as the sole carbon source and for turning colonies blue in the presence of X-gal. LacA, which contains a glucose-methanol-choline (GMC) oxidoreductase domain, has homology to the flavin subunit of Pectobacterium cypripedii's gluconate dehydrogenase. Sequence comparisons indicated that two genes near lacA, lacB and lacC, encode the other subunits of the membrane-bound dehydrogenase. In addition to lactose, all three lac genes are involved in the catabolism of three other β-galactosides (lactulose, lactitol, and methyl-β-d-galactoside) and two glucosides (salicin and trehalose). Dehydrogenase assays confirmed that the lac gene products oxidize lactose, salicin, and trehalose. This enzymatic activity is inducible, and increased lac expression in the presence of lactose and salicin likely contributes to the induction. Expression of lacA also depends on the presence of the lac genes, implying that the dehydrogenase participates in induction. The involvement of a dehydrogenase suggests that degradation of lactose and other sugars in C. crescentus may resemble a proposed pathway in Agrobacterium tumefaciens. PMID:20190087

  5. Glandular kallikrein in the innate immune system of Atlantic salmon (Salmo salar).

    PubMed

    Haussmann, D; Figueroa, J

    2011-02-15

    Glandular Kallikrein is a serine-protease with trypsin-like activity and is able to generate bioactive peptides from inactive precursors. We have evaluated the presence of this protease in the different organs of the Atlantic salmon (Salmo salar). The results clearly indicate that GK and PRL are generated in the same pituitary cells based on a co-localization by confocal microscopy. Based on probed cross-reactivity between C. striata and C. carpio glandular anti-GK antibodies, we used a homologous antibody to detect the presence of GK in several salmon tissues. We have evaluated the GK expression in healthy and defied fish. P. salmonis and V. ordalii. The GK immunoreaction in organs such as leukocytes, gills and skin is considerably increased in defied fish compared to healthy fish. This increase was present in the cells of the excretory kidney and in the intercellular tissue, where the development of hematopoietic and lymphocytic lines in fish take place. One of the most interesting organs to study was the skin, bearing in mind that this is a primary barrier to all pathogens. The skin of the defied fish exhibited an increase in immunoreactivity for glandular kallikrein similar to the protease found in mucus. An immunoreactive tissue kallikrein-like protein was identified and partially separated by perfusion chromatography. Enzymatic activity of salmon muscle prokallikrein was determined before and after trypsin activation. Kallikrein activity was characterized with respect to their ability to cleave the chromogenic leaving group, p-nitroanilide, from the peptidyl kallikrein and trypsin substrate. These findings constitute a important contribution to reveal the role of kallikrein in the innate immune system of fish. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. [Oxygen plasma-vulcanized deformable polydimethylsiloxane sheet culture substrates].

    PubMed

    Zhang, Yiyi; Tao, Zulai

    2003-06-01

    A method of preparing deformable polydimethylsiloxane sheet culture substrates by oxygen plasma vulcanization was developed. As compared with the traditional heating vulcanization method, the substrates prepared in this way have hydrophilic surfaces, the adhesion and spreading of cells both occur quickly, and the wrinkling deformation of substrates develops quickly, too. In addition, the changes of wrinkles during treatment of cytochalasin D were observed, and the result shows that this technique has high temporal resolution.

  7. Method for producing high quality oxide films on substrates

    DOEpatents

    Ruckman, Mark W.; Strongin, Myron; Gao, Yong L.

    1993-01-01

    A method for providing an oxide film of a material on the surface of a substrate using a reactive deposition of the material onto the substrate surface in the presence of a solid or liquid layer of an oxidizing gas. The oxidizing gas is provided on the substrate surface in an amount sufficient to dissipate the latent heat of condensation occurring during deposition as well as creating a favorable oxidizing environment for the material.

  8. Conversion of fullerenes to diamond

    DOEpatents

    Gruen, Dieter M.

    1993-01-01

    A method of forming synthetic diamond on a substrate is disclosed. The method involves providing a substrate surface covered with a fullerene or diamond coating, positioning a fullerene in an ionization source, creating a fullerene vapor, ionizing fullerene molecules, accelerating the fullerene ions to energies above 250 eV to form a fullerene ion beam, impinging the fullerene ion beam on the substrate surface and continuing these steps to obtain a diamond thickness on the substrate.

  9. Conversion of fullerenes to diamond

    DOEpatents

    Gruen, Dieter M.

    1994-01-01

    A method of forming synthetic diamond on a substrate. The method involves providing a substrate surface covered with a fullerene or diamond coating, positioning a fullerene in an ionization source, creating a fullerene vapor, ionizing fullerene molecules, accelerating the fullerene ions to energies above 250 eV to form a fullerene ion beam, impinging the fullerene ion beam on the substrate surface and continuing these steps to obtain a diamond film thickness on the substrate.

  10. Method and apparatus for preparing multiconductor cable with flat conductors

    NASA Technical Reports Server (NTRS)

    Marcell, G. V. (Inventor)

    1969-01-01

    A method and apparatus for preparing flat conductor cable having a plurality of ribbon-like conductors disposed upon and adhesively bonded to the surface of a substrate is described. The conductors are brought into contact with the substrate surface, and while maintained in axial tension on said substrate, the combination is seated on a yieldably compressible layer to permit the conductor to become embedded into the surface of the substrate film.

  11. Fiber optic detector and method for using same for detecting chemical species

    DOEpatents

    Baylor, Lewis C.; Buchanan, Bruce R.

    1995-01-01

    An optical sensing device for uranyl and other substances, a method for making an optical sensing device and a method for chemically binding uranyl and other indicators to glass, quartz, cellulose and similar substrates. The indicator, such as arsenazo III, is immobilized on the substrate using a chemical binding process. The immobilized arsenazo III causes uranyl from a fluid sample to bind irreversibly to the substrate at its active sites, thus causing absorption of a portion of light transmitted through the substrate. Determination of the amount of light absorbed, using conventional means, yields the concentration of uranyl present in the sample fluid. The binding of uranyl on the substrate can be reversed by subsequent exposure of the substrate to a solution of 2,6-pyridinedicarboxylic acid. The chemical binding process is suitable for similarly binding other indicators, such as bromocresol green.

  12. Method for fabrication of high temperature superconductors

    DOEpatents

    Balachandran, Uthamalingam; Ma, Beihai; Miller, Dean

    2006-03-14

    A layered article of manufacture and a method of manufacturing same is disclosed. A substrate has a biaxially textured MgO crystalline layer having the c-axes thereof inclined with respect to the plane of the substrate deposited thereon. A layer of one or more of YSZ or Y2O3 and then a layer of CeO2 is deposited on the MgO. A crystalline superconductor layer with the c-axes thereof normal to the plane of the substrate is deposited on the CeO2 layer. Deposition of the MgO layer on the substrate is by the inclined substrate deposition method developed at Argonne National Laboratory. Preferably, the MgO has the c-axes thereof inclined with respect to the normal to the substrate in the range of from about 10.degree. to about 40.degree. and YBCO superconductors are used.

  13. Method for fabrication of high temperature superconductors

    DOEpatents

    Balachandran, Uthamalingam [Hinsdale, IL; Ma, Beihai [Naperville, IL; Miller, Dean [Darien, IL

    2009-07-14

    A layered article of manufacture and a method of manufacturing same is disclosed. A substrate has a biaxially textured MgO crystalline layer having the c-axes thereof inclined with respect to the plane of the substrate deposited thereon. A layer of one or more of YSZ or Y.sub.2O.sub.3 and then a layer of CeO.sub.2 is deposited on the MgO. A crystalline superconductor layer with the c-axes thereof normal to the plane of the substrate is deposited on the CeO.sub.2 layer. Deposition of the MgO layer on the substrate is by the inclined substrate deposition method developed at Argonne National Laboratory. Preferably, the MgO has the c-axes thereof inclined with respect to the normal to the substrate in the range of from about 10.degree. to about 40.degree. and YBCO superconductors are used.

  14. Die singulation method

    DOEpatents

    Swiler, Thomas P.; Garcia, Ernest J.; Francis, Kathryn M.

    2013-06-11

    A method is disclosed for singulating die from a semiconductor substrate (e.g. a semiconductor-on-insulator substrate or a bulk silicon substrate) containing an oxide layer (e.g. silicon dioxide or a silicate glass) and one or more semiconductor layers (e.g. monocrystalline or polycrystalline silicon) located above the oxide layer. The method etches trenches through the substrate and through each semiconductor layer about the die being singulated, with the trenches being offset from each other around at least a part of the die so that the oxide layer between the trenches holds the substrate and die together. The trenches can be anisotropically etched using a Deep Reactive Ion Etching (DRIE) process. After the trenches are etched, the oxide layer between the trenches can be etched away with an HF etchant to singulate the die. A release fixture can be located near one side of the substrate to receive the singulated die.

  15. Die singulation method

    DOEpatents

    Swiler, Thomas P [Albuquerque, NM; Garcia, Ernest J [Albuquerque, NM; Francis, Kathryn M [Rio Rancho, NM

    2014-01-07

    A method is disclosed for singulating die from a semiconductor substrate (e.g. a semiconductor-on-insulator substrate or a bulk silicon substrate) containing an oxide layer (e.g. silicon dioxide or a silicate glass) and one or more semiconductor layers (e.g. monocrystalline or polycrystalline silicon) located above the oxide layer. The method etches trenches through the substrate and through each semiconductor layer about the die being singulated, with the trenches being offset from each other around at least a part of the die so that the oxide layer between the trenches holds the substrate and die together. The trenches can be anisotropically etched using a Deep Reactive Ion Etching (DRIE) process. After the trenches are etched, the oxide layer between the trenches can be etched away with a HF etchant to singulate the die. A release fixture can be located near one side of the substrate to receive the singulated die.

  16. Method of making an apparatus for transpiration cooling of substrates such as turbine airfoils

    DOEpatents

    Alvin, Mary Anne; Anderson, Iver; Heidlof, Andy; White, Emma; McMordie, Bruce

    2017-02-28

    A method and apparatus for generating transpiration cooling using an oxidized porous HTA layer metallurgically bonded to a substrate having micro-channel architectures. The method and apparatus generates a porous HTA layer by spreading generally spherical HTA powder particles on a substrate, partially sintering under O.sub.2 vacuum until the porous HTA layer exhibits a porosity between 20% and 50% and a neck size ratio between 0.1 and 0.5, followed by a controlled oxidation generating an oxidation layer of alumina, chromia, or silica at a thickness of about 20 to about 500 nm. In particular embodiments, the oxidized porous HTA layer and the substrate comprise Ni as a majority element. In other embodiments, the oxidized porous HTA layer and the substrate further comprise Al, and in additional embodiments, the oxidized porous HTA layer and the substrate comprise .gamma.-Ni+.gamma.'-Ni.sub.3Al.

  17. Articles for high temperature service and methods for their manufacture

    DOEpatents

    Sarrafi-Nour, Reza; Meschter, Peter Joel; Johnson, Curtis Alan; Luthra, Krishan Lal; Rosenzweig, Larry Steven

    2016-06-14

    An article for use in aggressive environments is presented. In one embodiment, the article comprises a substrate and a self-sealing and substantially hermetic sealing layer comprising an alkaline-earth aluminosilicate disposed over the bondcoat. The substrate may be any high-temperature material, including, for instance, silicon-bearing ceramics and ceramic matrix composites. A method for making such articles is also presented. The method comprises providing a substrate; disposing a self-sealing alkaline-earth aluminosilicate layer over the substrate; and heating the sealing layer to a sealing temperature at which at least a portion of the sealing layer will flow.

  18. Powder-in-tube and thick-film methods of fabricating high temperature superconductors having enhanced biaxial texture

    DOEpatents

    Goyal, Amit; Kroeger, Donald M.

    2003-11-11

    A method for forming an electronically active biaxially textured article includes the steps of providing a substrate having a single crystal metal or metal alloy surface, deforming the substrate to form an elongated substrate surface having biaxial texture and depositing an epitaxial electronically active layer on the biaxially textured surface. The method can include at least one annealing step after the deforming step to produce the biaxially textured substrate surface. The invention can be used to form improved biaxially textured articles, such as superconducting wire and tape articles having improved J.sub.c values.

  19. Methods for using atomic layer deposition to produce a film for solid state electrolytes and protective electrode coatings for lithium batteries

    DOEpatents

    Elam, Jeffrey W.; Meng, Xiangbo

    2018-03-13

    A method for using atomic layer deposition to produce a film configured for use in an anode, cathode, or solid state electrolyte of a lithium-ion battery or a lithium-sulfur battery. The method includes repeating a cycle for a predetermined number of times in an inert atmosphere. The cycle includes exposing a substrate to a first precursor, purging the substrate with inert gas, exposing the substrate to a second precursor, and purging the substrate with inert gas. The film is a metal sulfide.

  20. Method of producing an electronic unit having a polydimethylsiloxane substrate and circuit lines

    DOEpatents

    Davidson, James Courtney [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA; Maghribi, Mariam N [Livermore, CA; Benett, William J [Livermore, CA; Hamilton, Julie K [Tracy, CA; Tovar, Armando R [San Antonio, TX

    2012-06-19

    A system of metalization in an integrated polymer microsystem. A flexible polymer substrate is provided and conductive ink is applied to the substrate. In one embodiment the flexible polymer substrate is silicone. In another embodiment the flexible polymer substrate comprises poly(dimethylsiloxane).

Top