Sample records for chronically implanted microwires

  1. The Effects of Intraspinal Microstimulation on Spinal Cord Tissue in the Rat

    PubMed Central

    Bamford, Jeremy A.; Todd, Kathryn G.; Mushahwar, Vivian K.

    2010-01-01

    Intraspinal microstimulation (ISMS) involves the implantation of microwires into the spinal cord below the level of an injury to excite neural networks involved in the control of locomotion in the lower limbs. The goal of this study was to examine the potential spinal cord damage that might occur with chronic ISMS. We employed functional measures of force recruitment and immunohistochemical processing of serial spinal cord sections to evaluate any damage induced by spinal transection, implantation of ISMS arrays, and electrical stimulation of 4 hours/day for 30 days. Functional measurements showed no change in force recruitment following transection and chronic ISMS, indicating no changes to underlying neural networks. The implantation of sham intraspinal microwires produced a spatially-limited increase in the density of microglia/macrophages and GFAP+ astrocytes adjacent to the microwire tracks, indicating a persistent immune response. Most importantly, these results were not different from those around microwires that were chronically pulsed with charge levels up to 48 nC/phase. Likewise, measurements of neuronal density indicated no decrease in neuronal cell bodies in the ventral grey matter surrounding ISMS microwires (243.6/mm2 ± 35.3/mm2) compared to tissue surrounding sham microwires (207.8/mm2 ± 38.8/mm2). We conclude that the implantation of intraspinal microwires and chronic application of ISMS are well tolerated by spinal cord tissue. PMID:20430436

  2. A simple method for fabricating microwire tetrode with sufficient rigidity and integrity without a heat-fusing process.

    PubMed

    Liao, Yi-Fang; Tsai, Meng-Li; Yen, Chen-Tung; Cheng, Chiung-Hsiang

    2011-02-15

    Heat-fusing is a common process for fabricating microwire tetrodes. However, it is time-consuming, and the high-temperature treatment can easily cause the insulation of the microwire to overheat leading to short circuits. We herein provide a simple, fast method to fabricate microwire tetrodes without the heat-fusion process. By increasing the twisting density, we were able to fabricate tetrodes with good rigidity and integrity. This kind of tetrode showed good recording quality, penetrated the brain surface easily, and remained intact after chronic implantation. This method requires only general laboratory tools and is relatively simple even for inexperienced workers. © 2010 Elsevier B.V. All rights reserved.

  3. Ultrasoft microwire neural electrodes improve chronic tissue integration

    PubMed Central

    Du, Zhanhong Jeff; Kolarcik, Christi L.; Kozai, Takashi D.Y.; Luebben, Silvia D.; Sapp, Shawn A.; Zheng, Xin Sally; Nabity, James A.; Cui, X. Tracy

    2017-01-01

    Chronically implanted neural multi-electrode arrays (MEA) are an essential technology for recording electrical signals from neurons and/or modulating neural activity through stimulation. However, current MEAs, regardless of the type, elicit an inflammatory response that ultimately leads to device failure. Traditionally, rigid materials like tungsten and silicon have been employed to interface with the relatively soft neural tissue. The large stiffness mismatch is thought to exacerbate the inflammatory response. In order to minimize the disparity between the device and the brain, we fabricated novel ultrasoft electrodes consisting of elastomers and conducting polymers with mechanical properties much more similar to those of brain tissue than previous neural implants. In this study, these ultrasoft microelectrodes were inserted and released using a stainless steel shuttle with polyethyleneglycol (PEG) glue. The implanted microwires showed functionality in acute neural stimulation. When implanted for 1 or 8 weeks, the novel soft implants demonstrated significantly reduced inflammatory tissue response at week 8 compared to tungsten wires of similar dimension and surface chemistry. Furthermore, a higher degree of cell body distortion was found next to the tungsten implants compared to the polymer implants. Our results support the use of these novel ultrasoft electrodes for long term neural implants. PMID:28185910

  4. Methods for implantation of micro-wire bundles and optimization of single/multiunit recordings from human mesial temporal lobe

    PubMed Central

    Misra, A; Burke, JF; Ramayya, A; Jacobs, J; Sperling, MR; Moxon, KA; Kahana, MJ; Evans, JJ; Sharan, AD

    2014-01-01

    Objective The authors report methods developed for the implantation of micro-wire bundles into mesial temporal lobe structures and subsequent single neuron recording in epileptic patients undergoing in-patient diagnostic monitoring. This is done with the intention of lowering the perceived barriers to routine single neuron recording from deep brain structures in the clinical setting. Approach Over a 15 month period, 11 patients were implanted with platinum micro-wire bundles into mesial temporal structures. Protocols were developed for A) monitoring electrode integrity through impedance testing, B) ensuring continuous 24-7 recording, C) localizing micro-wire position and “splay” pattern and D) monitoring grounding and referencing to maintain the quality of recordings. Main Result Five common modes of failure were identified: 1) broken micro-wires from acute tensile force, 2) broken micro-wires from cyclic fatigue at stress points, 3) poor in-vivo micro-electrode separation, 4) motion artifact and 5) deteriorating ground connection and subsequent drop in common mode noise rejection. Single neurons have been observed up to 14 days post implantation and on 40% of micro-wires. Significance Long-term success requires detailed review of each implant by both the clinical and research teams to identify failure modes, and appropriate refinement of techniques while moving forward. This approach leads to reliable unit recordings without prolonging operative times, which will help increase the availability and clinical viability of human single neuron data. PMID:24608589

  5. Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black

    PubMed Central

    Desai, Sharanya Arcot; Rolston, John D.; Guo, Liang; Potter, Steve M.

    2010-01-01

    Implantable microelectrode arrays (MEAs) have been a boon for neural stimulation and recording experiments. Commercially available MEAs have high impedances, due to their low surface area and small tip diameters, which are suitable for recording single unit activity. Lowering the electrode impedance, but preserving the small diameter, would provide a number of advantages, including reduced stimulation voltages, reduced stimulation artifacts and improved signal-to-noise ratio. Impedance reductions can be achieved by electroplating the MEAs with platinum (Pt) black, which increases the surface area but has little effect on the physical extent of the electrodes. However, because of the low durability of Pt black plating, this method has not been popular for chronic use. Sonicoplating (i.e. electroplating under ultrasonic agitation) has been shown to improve the durability of Pt black on the base metals of macro-electrodes used for cyclic voltammetry. This method has not previously been characterized for MEAs used in chronic neural implants. We show here that sonicoplating can lower the impedances of microwire multi-electrode arrays (MMEA) by an order of magnitude or more (depending on the time and voltage of electroplating), with better durability compared to pulsed plating or traditional DC methods. We also show the improved stimulation and recording performance that can be achieved in an in vivo implantation study with the sonicoplated low-impedance MMEAs, compared to high-impedance unplated electrodes. PMID:20485478

  6. Seven Years of Recording from Monkey Cortex with a Chronically Implanted Multiple Microelectrode

    PubMed Central

    Krüger, Jürgen; Caruana, Fausto; Volta, Riccardo Dalla; Rizzolatti, Giacomo

    2010-01-01

    A brush of 64 microwires was chronically implanted in the ventral premotor cortex of a macaque monkey. Contrary to common approaches, the wires were inserted from the white matter side. This approach, by avoiding mechanical pressure on the dura and pia mater during penetration, disturbed only minimally the cortical recording site. With this approach isolated potentials and multiunit activity were recorded for more than 7 years in about one-third of electrodes. The indirect insertion method also provided an excellent stability within each recording session, and in some cases even allowed recording from the same neurons for several years. Histological examination of the implanted brain region shows only a very marginal damage to the recording area. Advantages and problems related to long-term recording are discussed. PMID:20577628

  7. Ultrasoft microwire neural electrodes improve chronic tissue integration.

    PubMed

    Du, Zhanhong Jeff; Kolarcik, Christi L; Kozai, Takashi D Y; Luebben, Silvia D; Sapp, Shawn A; Zheng, Xin Sally; Nabity, James A; Cui, X Tracy

    2017-04-15

    Chronically implanted neural multi-electrode arrays (MEA) are an essential technology for recording electrical signals from neurons and/or modulating neural activity through stimulation. However, current MEAs, regardless of the type, elicit an inflammatory response that ultimately leads to device failure. Traditionally, rigid materials like tungsten and silicon have been employed to interface with the relatively soft neural tissue. The large stiffness mismatch is thought to exacerbate the inflammatory response. In order to minimize the disparity between the device and the brain, we fabricated novel ultrasoft electrodes consisting of elastomers and conducting polymers with mechanical properties much more similar to those of brain tissue than previous neural implants. In this study, these ultrasoft microelectrodes were inserted and released using a stainless steel shuttle with polyethyleneglycol (PEG) glue. The implanted microwires showed functionality in acute neural stimulation. When implanted for 1 or 8weeks, the novel soft implants demonstrated significantly reduced inflammatory tissue response at week 8 compared to tungsten wires of similar dimension and surface chemistry. Furthermore, a higher degree of cell body distortion was found next to the tungsten implants compared to the polymer implants. Our results support the use of these novel ultrasoft electrodes for long term neural implants. One critical challenge to the translation of neural recording/stimulation electrode technology to clinically viable devices for brain computer interface (BCI) or deep brain stimulation (DBS) applications is the chronic degradation of device performance due to the inflammatory tissue reaction. While many hypothesize that soft and flexible devices elicit reduced inflammatory tissue responses, there has yet to be a rigorous comparison between soft and stiff implants. We have developed an ultra-soft microelectrode with Young's modulus lower than 1MPa, closely mimicking the brain tissue modulus. Here, we present a rigorous histological comparison of this novel ultrasoft electrode and conventional stiff electrode with the same size, shape and surface chemistry, implanted in rat brains for 1-week and 8-weeks. Significant improvement was observed for ultrasoft electrodes, including inflammatory tissue reaction, electrode-tissue integration as well as mechanical disturbance to nearby neurons. A full spectrum of new techniques were developed in this study, from insertion shuttle to in situ sectioning of the microelectrode to automated cell shape analysis, all of which should contribute new methods to the field. Finally, we showed the electrical functionality of the ultrasoft electrode, demonstrating the potential of flexible neural implant devices for future research and clinical use. Copyright © 2017. Published by Elsevier Ltd.

  8. Neural Interfaces for Intracortical Recording: Requirements, Fabrication Methods, and Characteristics

    PubMed Central

    Szostak, Katarzyna M.; Grand, Laszlo; Constandinou, Timothy G.

    2017-01-01

    Implantable neural interfaces for central nervous system research have been designed with wire, polymer, or micromachining technologies over the past 70 years. Research on biocompatible materials, ideal probe shapes, and insertion methods has resulted in building more and more capable neural interfaces. Although the trend is promising, the long-term reliability of such devices has not yet met the required criteria for chronic human application. The performance of neural interfaces in chronic settings often degrades due to foreign body response to the implant that is initiated by the surgical procedure, and related to the probe structure, and material properties used in fabricating the neural interface. In this review, we identify the key requirements for neural interfaces for intracortical recording, describe the three different types of probes—microwire, micromachined, and polymer-based probes; their materials, fabrication methods, and discuss their characteristics and related challenges. PMID:29270103

  9. Neural Interfaces for Intracortical Recording: Requirements, Fabrication Methods, and Characteristics.

    PubMed

    Szostak, Katarzyna M; Grand, Laszlo; Constandinou, Timothy G

    2017-01-01

    Implantable neural interfaces for central nervous system research have been designed with wire, polymer, or micromachining technologies over the past 70 years. Research on biocompatible materials, ideal probe shapes, and insertion methods has resulted in building more and more capable neural interfaces. Although the trend is promising, the long-term reliability of such devices has not yet met the required criteria for chronic human application. The performance of neural interfaces in chronic settings often degrades due to foreign body response to the implant that is initiated by the surgical procedure, and related to the probe structure, and material properties used in fabricating the neural interface. In this review, we identify the key requirements for neural interfaces for intracortical recording, describe the three different types of probes-microwire, micromachined, and polymer-based probes; their materials, fabrication methods, and discuss their characteristics and related challenges.

  10. Braided multi-electrode probes: mechanical compliance characteristics and recordings from spinal cords

    PubMed Central

    Kim, Taegyo; Branner, Almut; Gulati, Tanuj

    2013-01-01

    Objective To test a novel braided multi-electrode probe design with compliance exceeding that of a 50-micron microwire, thus reducing micromotion and macromotion induced tissue stress. Approach We use up to 24 ultra-fine wires interwoven into a tubular braid to obtain a highly flexible multi-electrode probe. The tether-portion wires are simply non-braided extensions of the braid structure, allowing the microprobe to follow gross neural tissue movements. Mechanical calculation and direct measurements evaluated bending stiffness and axial compression forces in the probe and tether system. These were compared to 50μm Nichrome microwire standards. Recording tests were performed in decerebrate animals. Main results Mechanical bending tests on braids comprising 9.6μm or 12.7μm Nichrome wires showed that implants (braided portions) had 4 to 21 times better mechanical compliance than a single 50μm wire and non-braided tethers were 6 to 96 times better. Braided microprobes yielded robust neural recordings from animals’ spinal cords throughout cord motions. Significance Microwire electrode arrays that can record and withstand tissue micro- and macromotion of spinal cord tissues are demonstrated. This technology may provide a stable chronic neural interface into spinal cords of freely moving animals, is extensible to various applications, and may reduce mechanical tissue stress. PMID:23723128

  11. Braided multi-electrode probes: mechanical compliance characteristics and recordings from spinal cords

    NASA Astrophysics Data System (ADS)

    Kim, Taegyo; Branner, Almut; Gulati, Tanuj; Giszter, Simon F.

    2013-08-01

    Objective. To test a novel braided multi-electrode probe design with compliance exceeding that of a 50 µm microwire, thus reducing micromotion- and macromotion-induced tissue stress. Approach. We use up to 24 ultra-fine wires interwoven into a tubular braid to obtain a highly flexible multi-electrode probe. The tether-portion wires are simply non-braided extensions of the braid structure, allowing the microprobe to follow gross neural tissue movements. Mechanical calculation and direct measurements evaluated bending stiffness and axial compression forces in the probe and tether system. These were compared to 50 µm nichrome microwire standards. Recording tests were performed in decerebrate animals. Main results. Mechanical bending tests on braids comprising 9.6 or 12.7 µm nichrome wires showed that implants (braided portions) had 4 to 21 times better mechanical compliance than a single 50 µm wire and non-braided tethers were 6 to 96 times better. Braided microprobes yielded robust neural recordings from animals' spinal cords throughout cord motions. Significance. Microwire electrode arrays that can record and withstand tissue micro- and macromotion of spinal cord tissues are demonstrated. This technology may provide a stable chronic neural interface into spinal cords of freely moving animals, is extensible to various applications, and may reduce mechanical tissue stress.

  12. COMMUNICATION: Minocycline increases quality and longevity of chronic neural recordings

    NASA Astrophysics Data System (ADS)

    Rennaker, R. L.; Miller, J.; Tang, H.; Wilson, D. A.

    2007-06-01

    Brain/machine interfaces could potentially be used in the treatment of a host of neurological disorders ranging from paralysis to sensory deficits. Insertion of chronic micro-electrode arrays into neural tissue initiates a host of immunological responses, which typically leads to the formation of a cellular sheath around the implant, resulting in the loss of useful signals. Minocycline has been shown to have neuroprotective and neurorestorative effects in certain neural injury and neurodegenerative disease models. This study examined the effects of minocycline administration on the quality and longevity of chronic multi-channel microwire neural implants 1 week and 1 month post-implantation in auditory cortex. The mean signal-to-noise ratio for the minocycline group stabilized at the end of week 1 and remained above 4.6 throughout the following 3 weeks. The control group signal-to-noise ratio dropped throughout the duration of the study and at the end of 4 weeks was 2.6. Furthermore, 68% of electrodes from the minocycline group showed significant stimulus-driven activity at week 4 compared to 12.5% of electrodes in the control group. There was a significant reduction in the number of activated astrocytes around the implant in minocycline subjects, as well as a reduction in total area occupied by activated astrocytes at 1 and 4 weeks.

  13. Sub-meninges implantation reduces immune response to neural implants.

    PubMed

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  14. Sub-meninges Implantation Reduces Immune Response to Neural Implants

    PubMed Central

    Markwardt, Neil T.; Stokol, Jodi; Rennaker, Robert L.

    2013-01-01

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. PMID:23370311

  15. A Flexible Base Electrode Array for Intraspinal Microstimulation

    PubMed Central

    Khaled, I.; Elmallah, S.; Cheng, C.; Moussa, W.A.; Mushahwar, V.K.; Elias, A.L.

    2013-01-01

    In this paper, we report the development of a flexible base array of penetrating electrodes which can be used to interface with the spinal cord. A customizable and feasible fabrication protocol is described. The flexible base arrays were fabricated and implanted into surrogate cords which were elongated by 12%. The resulting strains were optically measured across the cord and compared to those associated with two types of electrodes arrays (one without a base and one with a rigid base connecting the electrodes). The deformation behavior of cords implanted with the flexible base arrays resembled the behavior of cords implanted with individual microwires that were not connected through a base. The results of the strain test were used to validate a 2D finite element model. The validated model was used to assess the stresses induced by the electrodes of the 3 types of arrays on the cord, and to examine how various design parameters (thickness, base modulus, etc.) impact the mechanical behavior of the electrode array. Rigid base arrays induced higher stresses on the cord than the flexible base arrays which in turn imposed higher stresses than the individual microwire implants. The developed flexible base array showed improvement over the rigid base array; however, its stiffness needs to be further reduced to emulate the mechanical behavior of individual microwire arrays without a base. PMID:23744656

  16. Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes

    NASA Astrophysics Data System (ADS)

    Xie, Chong; Liu, Jia; Fu, Tian-Ming; Dai, Xiaochuan; Zhou, Wei; Lieber, Charles M.

    2015-12-01

    Direct electrical recording and stimulation of neural activity using micro-fabricated silicon and metal micro-wire probes have contributed extensively to basic neuroscience and therapeutic applications; however, the dimensional and mechanical mismatch of these probes with the brain tissue limits their stability in chronic implants and decreases the neuron-device contact. Here, we demonstrate the realization of a three-dimensional macroporous nanoelectronic brain probe that combines ultra-flexibility and subcellular feature sizes to overcome these limitations. Built-in strains controlling the local geometry of the macroporous devices are designed to optimize the neuron/probe interface and to promote integration with the brain tissue while introducing minimal mechanical perturbation. The ultra-flexible probes were implanted frozen into rodent brains and used to record multiplexed local field potentials and single-unit action potentials from the somatosensory cortex. Significantly, histology analysis revealed filling-in of neural tissue through the macroporous network and attractive neuron-probe interactions, consistent with long-term biocompatibility of the device.

  17. Therapeutic intraspinal microstimulation improves forelimb function after cervical contusion injury

    NASA Astrophysics Data System (ADS)

    Kasten, M. R.; Sunshine, M. D.; Secrist, E. S.; Horner, P. J.; Moritz, C. T.

    2013-08-01

    Objective. Intraspinal microstimulation (ISMS) is a promising method for activating the spinal cord distal to an injury. The objectives of this study were to examine the ability of chronically implanted stimulating wires within the cervical spinal cord to (1) directly produce forelimb movements, and (2) assess whether ISMS stimulation could improve subsequent volitional control of paretic extremities following injury. Approach. We developed a technique for implanting intraspinal stimulating electrodes within the cervical spinal cord segments C6-T1 of Long-Evans rats. Beginning 4 weeks after a severe cervical contusion injury at C4-C5, animals in the treatment condition received therapeutic ISMS 7 hours/day, 5 days/week for the following 12 weeks. Main results. Over 12 weeks of therapeutic ISMS, stimulus-evoked forelimb movements were relatively stable. We also explored whether therapeutic ISMS promoted recovery of forelimb reaching movements. Animals receiving daily therapeutic ISMS performed significantly better than unstimulated animals during behavioural tests conducted without stimulation. Quantitative video analysis of forelimb movements showed that stimulated animals performed better in the movements reinforced by stimulation, including extending the elbow to advance the forelimb and opening the digits. While threshold current to elicit forelimb movement gradually increased over time, no differences were observed between chronically stimulated and unstimulated electrodes suggesting that no additional tissue damage was produced by the electrical stimulation. Significance. The results indicate that therapeutic intraspinal stimulation delivered via chronic microwire implants within the cervical spinal cord confers benefits extending beyond the period of stimulation, suggesting future strategies for neural devices to promote sustained recovery after injury.

  18. Therapeutic intraspinal microstimulation improves forelimb function after cervical contusion injury

    PubMed Central

    Kasten, M.R.; Sunshine, M.D.; Secrist, E.S.; Horner, P.J.; Moritz, C.T.

    2013-01-01

    Objective Intraspinal microstimulation (ISMS) is a promising method for activating the spinal cord distal to an injury. The objectives of this study were to examine the ability of chronically implanted stimulating wires within the cervical spinal cord to (1) directly produce forelimb movements, and (2) assess whether ISMS stimulation improved subsequent volitional control of paretic extremities following injury. Approach We developed a technique for implanting intraspinal stimulating electrodes within the cervical spinal cord segments C6-T1 of Long-Evans rats. Beginning 4 weeks after a severe cervical contusion injury at C4–C5, animals in the treatment condition received therapeutic ISMS 7 hours/day, 5 days/week for the following 12 weeks. Main Results Over 12 weeks of therapeutic ISMS, stimulus-evoked forelimb movements were relatively stable. We also explored whether therapeutic ISMS promotes recovery of forelimb reaching movements. Animals receiving daily therapeutic ISMS performed significantly better than unstimulated animals during behavioral tests conducted without stimulation. Quantitative video analysis of forelimb movements showed that stimulated animals performed better in the movements reinforced by stimulation, including extending the elbow to advance the forelimb and opening the digits. While threshold current to elicit forelimb movement gradually increased over time, no differences were observed between chronically stimulated and unstimulated electrodes suggesting that no additional tissue damage was produced by the electrical stimulation. Significance The results indicate that therapeutic intraspinal stimulation delivered via chronic microwire implants within the cervical spinal cord confers benefits extending beyond the period of stimulation, suggesting future strategies for neural devices to promote sustained recovery after injury. PMID:23715242

  19. A programmable closed-loop recording and stimulating wireless system for behaving small laboratory animals

    PubMed Central

    Angotzi, Gian Nicola; Boi, Fabio; Zordan, Stefano; Bonfanti, Andrea; Vato, Alessandro

    2014-01-01

    A portable 16-channels microcontroller-based wireless system for a bi-directional interaction with the central nervous system is presented in this work. The device is designed to be used with freely behaving small laboratory animals and allows recording of spontaneous and evoked neural activity wirelessly transmitted and stored on a personal computer. Biphasic current stimuli with programmable duration, frequency and amplitude may be triggered in real-time on the basis of the recorded neural activity as well as by the animal behavior within a specifically designed experimental setup. An intuitive graphical user interface was developed to configure and to monitor the whole system. The system was successfully tested through bench tests and in vivo measurements on behaving rats chronically implanted with multi-channels microwire arrays. PMID:25096831

  20. Rapid evaluation of the durability of cortical neural implants using accelerated aging with reactive oxygen species

    PubMed Central

    Takmakov, Pavel; Ruda, Kiersten; Phillips, K Scott; Isayeva, Irada S; Krauthamer, Victor; Welle, Cristin G

    2017-01-01

    Objective A challenge for implementing high bandwidth cortical brain–machine interface devices in patients is the limited functional lifespan of implanted recording electrodes. Development of implant technology currently requires extensive non-clinical testing to demonstrate device performance. However, testing the durability of the implants in vivo is time-consuming and expensive. Validated in vitro methodologies may reduce the need for extensive testing in animal models. Approach Here we describe an in vitro platform for rapid evaluation of implant stability. We designed a reactive accelerated aging (RAA) protocol that employs elevated temperature and reactive oxygen species (ROS) to create a harsh aging environment. Commercially available microelectrode arrays (MEAs) were placed in a solution of hydrogen peroxide at 87 °C for a period of 7 days. We monitored changes to the implants with scanning electron microscopy and broad spectrum electrochemical impedance spectroscopy (1 Hz–1 MHz) and correlated the physical changes with impedance data to identify markers associated with implant failure. Main results RAA produced a diverse range of effects on the structural integrity and electrochemical properties of electrodes. Temperature and ROS appeared to have different effects on structural elements, with increased temperature causing insulation loss from the electrode microwires, and ROS concentration correlating with tungsten metal dissolution. All array types experienced impedance declines, consistent with published literature showing chronic (>30 days) declines in array impedance in vivo. Impedance change was greatest at frequencies <10 Hz, and smallest at frequencies 1 kHz and above. Though electrode performance is traditionally characterized by impedance at 1 kHz, our results indicate that an impedance change at 1 kHz is not a reliable predictive marker of implant degradation or failure. Significance ROS, which are known to be present in vivo, can create structural damage and change electrical properties of MEAs. Broad-spectrum electrical impedance spectroscopy demonstrates increased sensitivity to electrode damage compared with single-frequency measurements. RAA can be a useful tool to simulate worst-case in vivo damage resulting from chronic electrode implantation, simplifying the device development lifecycle. PMID:25627426

  1. Method for alignment of microwires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beardslee, Joseph A.; Lewis, Nathan S.; Sadtler, Bryce

    2017-01-24

    A method of aligning microwires includes modifying the microwires so they are more responsive to a magnetic field. The method also includes using a magnetic field so as to magnetically align the microwires. The method can further include capturing the microwires in a solid support structure that retains the longitudinal alignment of the microwires when the magnetic field is not applied to the microwires.

  2. Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants

    PubMed Central

    Prasad, Abhishek; Xue, Qing-Shan; Dieme, Robert; Sankar, Viswanath; Mayrand, Roxanne C.; Nishida, Toshikazu; Streit, Wolfgang J.; Sanchez, Justin C.

    2014-01-01

    Pt/Ir electrodes have been extensively used in neurophysiology research in recent years as they provide a more inert recording surface as compared to tungsten or stainless steel. While floating microelectrode arrays (FMA) consisting of Pt/Ir electrodes are an option for neuroprosthetic applications, long-term in vivo functional performance characterization of these FMAs is lacking. In this study, we have performed comprehensive abiotic-biotic characterization of Pt/Ir arrays in 12 rats with implant periods ranging from 1 week up to 6 months. Each of the FMAs consisted of 16-channel, 1.5 mm long, and 75 μm diameter microwires with tapered tips that were implanted into the somatosensory cortex. Abiotic characterization included (1) pre-implant and post-explant scanning electron microscopy (SEM) to study recording site changes, insulation delamination and cracking, and (2) chronic in vivo electrode impedance spectroscopy. Biotic characterization included study of microglial responses using a panel of antibodies, such as Iba1, ED1, and anti-ferritin, the latter being indicative of blood-brain barrier (BBB) disruption. Significant structural variation was observed pre-implantation among the arrays in the form of irregular insulation, cracks in insulation/recording surface, and insulation delamination. We observed delamination and cracking of insulation in almost all electrodes post-implantation. These changes altered the electrochemical surface area of the electrodes and resulted in declining impedance over the long-term due to formation of electrical leakage pathways. In general, the decline in impedance corresponded with poor electrode functional performance, which was quantified via electrode yield. Our abiotic results suggest that manufacturing variability and insulation material as an important factor contributing to electrode failure. Biotic results show that electrode performance was not correlated with microglial activation (neuroinflammation) as we were able to observe poor performance in the absence of neuroinflammation, as well as good performance in the presence of neuroinflammation. One biotic change that correlated well with poor electrode performance was intraparenchymal bleeding, which was evident macroscopically in some rats and presented microscopically by intense ferritin immunoreactivity in microglia/macrophages. Thus, we currently consider intraparenchymal bleeding, suboptimal electrode fabrication, and insulation delamination as the major factors contributing toward electrode failure. PMID:24550823

  3. Correlation of mRNA Expression and Signal Variability in Chronic Intracortical Electrodes.

    PubMed

    Falcone, Jessica D; Carroll, Sheridan L; Saxena, Tarun; Mandavia, Dev; Clark, Alexus; Yarabarla, Varun; Bellamkonda, Ravi V

    2018-01-01

    The goal for this research was to identify molecular mechanisms that explain animal-to-animal variability in chronic intracortical recordings. Microwire electrodes were implanted into Sprague Dawley rats at an acute (1 week) and a chronic (14 weeks) time point. Weekly recordings were conducted, and action potentials were evoked in the barrel cortex by deflecting the rat's whiskers. At 1 and 14 weeks, tissue was collected, and mRNA was extracted. mRNA expression was compared between 1 and 14 weeks using a high throughput multiplexed qRT-PCR. Pearson correlation coefficients were calculated between mRNA expression and signal-to-noise ratios at 14 weeks. At 14 weeks, a positive correlation between signal-to-noise ratio (SNR) and NeuN and GFAP mRNA expression was observed, indicating a relationship between recording strength and neuronal population, as well as reactive astrocyte activity. The inflammatory state around the electrode interface was evaluated using M1-like and M2-like markers. Expression for both M1-like and M2-like mRNA markers remained steady from 1 to 14 weeks. Anti-inflammatory markers, CD206 and CD163, however, demonstrated a significant positive correlation with SNR quality at 14 weeks. VE-cadherin, a marker for adherens junctions, and PDGFR-β, a marker for pericytes, both partial representatives of blood-brain barrier health, had a positive correlation with SNR at 14 weeks. Endothelial adhesion markers revealed a significant increase in expression at 14 weeks, while CD45, a pan-leukocyte marker, significantly decreased at 14 weeks. No significant correlation was found for either the endothelial adhesion or pan-leukocyte markers. A positive correlation between anti-inflammatory and blood-brain barrier health mRNA markers with electrophysiological efficacy of implanted intracortical electrodes has been demonstrated. These data reveal potential mechanisms for further evaluation to determine potential target mechanisms to improve consistency of intracortical electrodes recordings and reduce animal-to-animal/implant-to-implant variability.

  4. Elastomeric and soft conducting microwires for implantable neural interfaces

    PubMed Central

    Kolarcik, Christi L.; Luebben, Silvia D.; Sapp, Shawn A.; Hanner, Jenna; Snyder, Noah; Kozai, Takashi D.Y.; Chang, Emily; Nabity, James A.; Nabity, Shawn T.; Lagenaur, Carl F.; Cui, X. Tracy

    2015-01-01

    Current designs for microelectrodes used for interfacing with the nervous system elicit a characteristic inflammatory response that leads to scar tissue encapsulation, electrical insulation of the electrode from the tissue and ultimately failure. Traditionally, relatively stiff materials like tungsten and silicon are employed which have mechanical properties several orders of magnitude different from neural tissue. This mechanical mismatch is thought to be a major cause of chronic inflammation and degeneration around the device. In an effort to minimize the disparity between neural interface devices and the brain, novel soft electrodes consisting of elastomers and intrinsically conducting polymers were fabricated. The physical, mechanical and electrochemical properties of these materials were extensively characterized to identify the formulations with the optimal combination of parameters including Young’s modulus, elongation at break, ultimate tensile strength, conductivity, impedance and surface charge injection. Our final electrode has a Young’s modulus of 974 kPa which is five orders of magnitude lower than tungsten and significantly lower than other polymer-based neural electrode materials. In vitro cell culture experiments demonstrated the favorable interaction between these soft materials and neurons, astrocytes and microglia, with higher neuronal attachment and a two-fold reduction in inflammatory microglia attachment on soft devices compared to stiff controls. Surface immobilization of neuronal adhesion proteins on these microwires further improved the cellular response. Finally, in vivo electrophysiology demonstrated the functionality of the elastomeric electrodes in recording single unit activity in the rodent visual cortex. The results presented provide initial evidence in support of the use of soft materials in neural interface applications. PMID:25993261

  5. Gate- and Light-Tunable pn Heterojunction Microwire Arrays Fabricated via Evaporative Assembly.

    PubMed

    Park, Jae Hoon; Kim, Jong Su; Choi, Young Jin; Lee, Wi Hyoung; Lee, Dong Yun; Cho, Jeong Ho

    2017-02-01

    One-dimensional (1D) nano/microwires have attracted considerable attention as versatile building blocks for use in diverse electronic, optoelectronic, and magnetic device applications. The large-area assembly of nano/microwires at desired positions presents a significant challenge for developing high-density electronic devices. Here, we demonstrated the fabrication of cross-stacked pn heterojunction diode arrays by integrating well-aligned inorganic and organic microwires fabricated via evaporative assembly. We utilized solution-processed n-type inorganic indium-gallium-zinc-oxide (IGZO) microwires and p-type organic 6,13-bis(triisopropylsilylethynyl)pentacene (TIPS-PEN) microwires. The formation of organic TIPS-PEN semiconductor microwire and their electrical properties were optimized by controlling both the amounts of added insulating polymer and the widths of the microwires. The resulting cross-stacked IGZO/TIPS-PEN microwire pn heterojunction devices exhibited rectifying behavior with a forward-to-reverse bias current ratio exceeding 10 2 . The ultrathin nature of the underlying n-type IGZO microwires yielded gate tunability in the charge transport behaviors, ranging from insulating to rectifying. The rectifying behaviors of the heterojunction devices could be modulated by controlling the optical power of the irradiated light. The fabrication of semiconducting microwires through evaporative assembly provides a facile and reliable approach to patterning or positioning 1D microwires for the fabrication of future flexible large-area electronics.

  6. Corrosion of Tungsten Microelectrodes used in Neural Recording Applications

    PubMed Central

    Patrick, Erin; Orazem, Mark E.; Sanchez, Justin C.; Nishida, Toshikazu

    2011-01-01

    In neuroprosthetic applications, long-term electrode viability is necessary for robust recording of the activity of neural populations used for generating communication and control signals. The corrosion of tungsten microwire electrodes used for intracortical recording applications was analyzed in a controlled bench-top study and compared to the corrosion of tungsten microwires used in an in vivo study. Two electrolytes were investigated for the benchtop electrochemical analysis: 0.9% phosphate buffered saline (PBS) and 0.9% PBS containing 30 mM of hydrogen peroxide. The oxidation and reduction reactions responsible for corrosion were found by measurement of the open circuit potential and analysis of Pourbaix diagrams. Dissolution of tungsten to form the tungstic ion was found to be the corrosion mechanism. The corrosion rate was estimated from the polarization resistance, which was extrapolated from the electrochemical impedance spectroscopy data. The results show that tungsten microwires in an electrolyte of PBS have a corrosion rate of 300–700 µm/yr. The corrosion rate for tungsten microwires in an electrolyte containing PBS and 30 mM H2O2 is accelerated to 10,000–20,000 µm/yr. The corrosion rate was found to be controlled by the concentration of the reacting species in the cathodic reaction (e.g. O2 and H2O2). The in vivo corrosion rate, averaged over the duration of implantation, was estimated to be 100 µm/yr. The reduced in vivo corrosion rate as compared to the benchtop rate is attributed to decreased rate of oxygen diffusion caused by the presence of a biological film and a reduced concentration of available oxygen in the brain. PMID:21470563

  7. Corrosion of tungsten microelectrodes used in neural recording applications.

    PubMed

    Patrick, Erin; Orazem, Mark E; Sanchez, Justin C; Nishida, Toshikazu

    2011-06-15

    In neuroprosthetic applications, long-term electrode viability is necessary for robust recording of the activity of neural populations used for generating communication and control signals. The corrosion of tungsten microwire electrodes used for intracortical recording applications was analyzed in a controlled bench-top study and compared to the corrosion of tungsten microwires used in an in vivo study. Two electrolytes were investigated for the bench-top electrochemical analysis: 0.9% phosphate buffered saline (PBS) and 0.9% PBS containing 30 mM of hydrogen peroxide. The oxidation and reduction reactions responsible for corrosion were found by measurement of the open circuit potential and analysis of Pourbaix diagrams. Dissolution of tungsten to form the tungstic ion was found to be the corrosion mechanism. The corrosion rate was estimated from the polarization resistance, which was extrapolated from the electrochemical impedance spectroscopy data. The results show that tungsten microwires in an electrolyte of PBS have a corrosion rate of 300-700 μm/yr. The corrosion rate for tungsten microwires in an electrolyte containing PBS and 30 mM H₂O₂ is accelerated to 10,000-20,000 μm/yr. The corrosion rate was found to be controlled by the concentration of the reacting species in the cathodic reaction (e.g. O₂ and H₂O₂). The in vivo corrosion rate, averaged over the duration of implantation, was estimated to be 100 μm/yr. The reduced in vivo corrosion rate as compared to the bench-top rate is attributed to decreased rate of oxygen diffusion caused by the presence of a biological film and a reduced concentration of available oxygen in the brain. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Plasticity and Activation of Spared Intraspinal Respiratory Circuits Following Spinal Cord Injury

    DTIC Science & Technology

    2015-10-01

    scheduled to present these data at the Spring 2016 Experimental Biology Meeting in San Diego, CA, and thus fully anticipate that analysis will be...that had been deprived of descending drive from the brainstem from an acute cervical spinal cord injury in an endogenous rhythmic manner. To address...epidural stimulation. Major Task 3: Analysis of Tissue Responses to Microwire Implantation These experiments, which were incorporated into the revised

  9. Characterization of long-range functional connectivity in epileptic networks by neuronal spike-triggered local field potentials

    NASA Astrophysics Data System (ADS)

    Lopour, Beth A.; Staba, Richard J.; Stern, John M.; Fried, Itzhak; Ringach, Dario L.

    2016-04-01

    Objective. Quantifying the relationship between microelectrode-recorded multi-unit activity (MUA) and local field potentials (LFPs) in distinct brain regions can provide detailed information on the extent of functional connectivity in spatially widespread networks. These methods are common in studies of cognition using non-human animal models, but are rare in humans. Here we applied a neuronal spike-triggered impulse response to electrophysiological recordings from the human epileptic brain for the first time, and we evaluate functional connectivity in relation to brain areas supporting the generation of seizures. Approach. Broadband interictal electrophysiological data were recorded from microwires adapted to clinical depth electrodes that were implanted bilaterally using stereotactic techniques in six presurgical patients with medically refractory epilepsy. MUA and LFPs were isolated in each microwire, and we calculated the impulse response between the MUA on one microwire and the LFPs on a second microwire for all possible MUA/LFP pairs. Results were compared to clinical seizure localization, including sites of seizure onset and interictal epileptiform discharges. Main results. We detected significant interictal long-range functional connections in each subject, in some cases across hemispheres. Results were consistent between two independent datasets, and the timing and location of significant impulse responses reflected anatomical connectivity. However, within individual subjects, the spatial distribution of impulse responses was unique. In two subjects with clear seizure localization and successful surgery, the epileptogenic zone was associated with significant impulse responses. Significance. The results suggest that the spike-triggered impulse response can provide valuable information about the neuronal networks that contribute to seizures using only interictal data. This technique will enable testing of specific hypotheses regarding functional connectivity in epilepsy and the relationship between functional properties and imaging findings. Beyond epilepsy, we expect that the impulse response could be more broadly applied as a measure of long-range functional connectivity in studies of cognition.

  10. Characterization of long-range functional connectivity in epileptic networks by neuronal spike-triggered local field potentials

    PubMed Central

    Lopour, Beth A; Staba, Richard J; Stern, John M; Fried, Itzhak; Ringach, Dario L

    2017-01-01

    Objective Quantifying the relationship between microelectrode-recorded multi-unit activity (MUA) and local field potentials (LFPs) in distinct brain regions can provide detailed information on the extent of functional connectivity in spatially widespread networks. These methods are common in studies of cognition using non-human animal models, but are rare in humans. Here we applied a neuronal spike-triggered impulse response to electrophysiological recordings from the human epileptic brain for the first time, and we evaluate functional connectivity in relation to brain areas supporting the generation of seizures. Approach Broadband interictal electrophysiological data were recorded from microwires adapted to clinical depth electrodes that were implanted bilaterally using stereotactic techniques in six presurgical patients with medically refractory epilepsy. MUA and LFPs were isolated in each microwire, and we calculated the impulse response between the MUA on one microwire and the LFPs on a second microwire for all possible MUA/LFP pairs. Results were compared to clinical seizure localization, including sites of seizure onset and interictal epileptiform discharges. Main results We detected significant interictal long-range functional connections in each subject, in some cases across hemispheres. Results were consistent between two independent datasets, and the timing and location of significant impulse responses reflected anatomical connectivity. However, within individual subjects, the spatial distribution of impulse responses was unique. In two subjects with clear seizure localization and successful surgery, the epileptogenic zone was associated with significant impulse responses. Significance The results suggest that the spike-triggered impulse response can provide valuable information about the neuronal networks that contribute to seizures using only interictal data. This technique will enable testing of specific hypotheses regarding functional connectivity in epilepsy and the relationship between functional properties and imaging findings. Beyond epilepsy, we expect that the impulse response could be more broadly applied as a measure of long-range functional connectivity in studies of cognition. PMID:26975603

  11. Single n-GaN microwire/p-Silicon thin film heterojunction light-emitting diode.

    PubMed

    Ahn, Jaehui; Mastro, Michael A; Klein, Paul B; Hite, Jennifer K; Feigelson, Boris; Eddy, Charles R; Kim, Jihyun

    2011-10-24

    The emission and waveguiding properties of individual GaN microwires as well as devices based on an n-GaN microwire/p-Si (100) junction were studied for relevance in optoelectronics and optical circuits. Pulsed photoluminescence of the GaN microwire excited in the transverse or longitudinal direction demonstrated gain. These n-type GaN microwires were positioned mechanically or by dielectrophoretic force onto pre-patterned electrodes on a p-type Si (100) substrate. Electroluminescence from this p-n point junction was characteristic of a heterostructure light-emitting diode. Additionally, waveguiding was observed along the length of the microwire for light originating from photoluminescence as well as from electroluminescence generated at the p-n junction. © 2011 Optical Society of America

  12. Growth of GaN micro/nanolaser arrays by chemical vapor deposition.

    PubMed

    Liu, Haitao; Zhang, Hanlu; Dong, Lin; Zhang, Yingjiu; Pan, Caofeng

    2016-09-02

    Optically pumped ultraviolet lasing at room temperature based on GaN microwire arrays with Fabry-Perot cavities is demonstrated. GaN microwires have been grown perpendicularly on c-GaN/sapphire substrates through simple catalyst-free chemical vapor deposition. The GaN microwires are [0001] oriented single-crystal structures with hexagonal cross sections, each with a diameter of ∼1 μm and a length of ∼15 μm. A possible growth mechanism of the vertical GaN microwire arrays is proposed. Furthermore, we report room-temperature lasing in optically pumped GaN microwire arrays based on the Fabry-Perot cavity. Photoluminescence spectra exhibit lasing typically at 372 nm with an excitation threshold of 410 kW cm(-2). The result indicates that these aligned GaN microwire arrays may offer promising prospects for ultraviolet-emitting micro/nanodevices.

  13. Radial direct bandgap p-i-n GaNP microwire solar cells with enhanced short circuit current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sukrittanon, Supanee; Liu, Ren; Pan, Janet L.

    2016-08-07

    We report the demonstration of dilute nitride heterostructure core/shell microwire solar cells utilizing the combination of top-down reactive-ion etching to create the cores (GaP) and molecular beam epitaxy to create the shells (GaNP). Systematic studies of cell performance over a series of microwire lengths, array periods, and microwire sidewall morphologies examined by transmission electron microscopy were conducted to shed light on performance-limiting factors and to optimize the cell efficiency. We show by microscopy and correlated external quantum efficiency characterization that the open circuit voltage is degraded primarily due to the presence of defects at the GaP/GaNP interface and in themore » GaNP shells, and is not limited by surface recombination. Compared to thin film solar cells in the same growth run, the microwire solar cells exhibit greater short circuit current but poorer open circuit voltage due to greater light absorption and number of defects in the microwire structure, respectively. The comprehensive understanding presented in this work suggests that performance benefits of dilute nitride microwire solar cells can be achieved by further tuning of the epitaxial quality of the underlying materials.« less

  14. Radial direct bandgap p-i-n GaNP microwire solar cells with enhanced short circuit current

    NASA Astrophysics Data System (ADS)

    Sukrittanon, Supanee; Liu, Ren; Breeden, Michael C.; Pan, Janet L.; Jungjohann, K. L.; Tu, Charles W.; Dayeh, Shadi A.

    2016-08-01

    We report the demonstration of dilute nitride heterostructure core/shell microwire solar cells utilizing the combination of top-down reactive-ion etching to create the cores (GaP) and molecular beam epitaxy to create the shells (GaNP). Systematic studies of cell performance over a series of microwire lengths, array periods, and microwire sidewall morphologies examined by transmission electron microscopy were conducted to shed light on performance-limiting factors and to optimize the cell efficiency. We show by microscopy and correlated external quantum efficiency characterization that the open circuit voltage is degraded primarily due to the presence of defects at the GaP/GaNP interface and in the GaNP shells, and is not limited by surface recombination. Compared to thin film solar cells in the same growth run, the microwire solar cells exhibit greater short circuit current but poorer open circuit voltage due to greater light absorption and number of defects in the microwire structure, respectively. The comprehensive understanding presented in this work suggests that performance benefits of dilute nitride microwire solar cells can be achieved by further tuning of the epitaxial quality of the underlying materials.

  15. Radial direct bandgap p-i-n GaNP microwire solar cells with enhanced short circuit current

    DOE PAGES

    Sukrittanon, Supanee; Liu, Ren; Breeden, Michael C.; ...

    2016-08-07

    Here, we report the demonstration of dilute nitride heterostructure core/shell microwire solar cells utilizing the combination of top-down reactive-ion etching to create the cores (GaP) and molecular beam epitaxy to create the shells (GaNP). Systematic studies of cell performance over a series of microwire lengths, array periods, and microwire sidewall morphologies examined by transmission electron microscopy were conducted to shed light on performance-limiting factors and to optimize the cell efficiency. We also show by microscopy and correlated external quantum efficiency characterization that the open circuit voltage is degraded primarily due to the presence of defects at the GaP/GaNP interface andmore » in the GaNP shells, and is not limited by surface recombination. Compared to thin film solar cells in the same growth run, the microwire solar cells exhibit greater short circuit current but poorer open circuit voltage due to greater light absorption and number of defects in the microwire structure, respectively. Finally, we present performance benefits of dilute nitride microwire solar cells and show that it can be achieved by further tuning of the epitaxial quality of the underlying materials.« less

  16. Single electrode micro-stimulation of rat auditory cortex: an evaluation of behavioral performance.

    PubMed

    Rousche, Patrick J; Otto, Kevin J; Reilly, Mark P; Kipke, Daryl R

    2003-05-01

    A combination of electrophysiological mapping, behavioral analysis and cortical micro-stimulation was used to explore the interrelation between the auditory cortex and behavior in the adult rat. Auditory discriminations were evaluated in eight rats trained to discriminate the presence or absence of a 75 dB pure tone stimulus. A probe trial technique was used to obtain intensity generalization gradients that described response probabilities to mid-level tones between 0 and 75 dB. The same rats were then chronically implanted in the auditory cortex with a 16 or 32 channel tungsten microwire electrode array. Implanted animals were then trained to discriminate the presence of single electrode micro-stimulation of magnitude 90 microA (22.5 nC/phase). Intensity generalization gradients were created to obtain the response probabilities to mid-level current magnitudes ranging from 0 to 90 microA on 36 different electrodes in six of the eight rats. The 50% point (the current level resulting in 50% detections) varied from 16.7 to 69.2 microA, with an overall mean of 42.4 (+/-8.1) microA across all single electrodes. Cortical micro-stimulation induced sensory-evoked behavior with similar characteristics as normal auditory stimuli. The results highlight the importance of the auditory cortex in a discrimination task and suggest that micro-stimulation of the auditory cortex might be an effective means for a graded information transfer of auditory information directly to the brain as part of a cortical auditory prosthesis.

  17. Magnetostructural coupling and magnetocaloric effect in Ni-Mn-Ga-Cu microwires

    NASA Astrophysics Data System (ADS)

    Zhang, Xuexi; Qian, Mingfang; Zhang, Zhe; Wei, Longsha; Geng, Lin; Sun, Jianfei

    2016-02-01

    Ni-Mn-Ga-X microwires were produced by melt-extraction technique on a large scale. Their shape memory effect, superelasticity, and damping capacity have been demonstrated. Here, the excellent magnetocaloric effect was revealed in Ni-Mn-Ga-Cu microwires produced by melt-extraction and subsequent annealing. The overlap of the martensitic and magnetic transformations, i.e., magnetostructural coupling, was achieved in the annealed microwires. The magnetostructural coupling and wide martensitic transformation temperature range contribute to a large magnetic entropy change of -8.3 J/kg K with a wide working temperature interval of ˜13 K under a magnetic field of 50 kOe. Accordingly, a high refrigeration capacity of ˜78 J/kg was produced in the annealed microwires.

  18. Towards flexible asymmetric MSM structures using Si microwires through contact printing

    NASA Astrophysics Data System (ADS)

    Khan, S.; Lorenzelli, L.; Dahiya, R.

    2017-08-01

    This paper presents development of flexible metal-semiconductor-metal devices using silicon (Si) microwires. Monocrystalline Si in the shape of microwires are used which are developed through standard photolithography and etching. These microwires are assembled on secondary flexible substrates through a dry transfer printing by using a polydimethylsiloxane stamp. The conductive patterns on Si microwires are printed using a colloidal silver nanoparticles based solution and an organic conductor i.e. poly (3,4-ethylene dioxthiophene) doped with poly (styrene sulfonate). A custom developed spray coating technique is used for conductive patterns on Si microwires. A comparative study of the current-voltage (I-V) responses is carried out in flat and bent orientations as well as the response to the light illumination of the wires is explored. Current variations as high as 17.1 μA are recorded going from flat to bend conditions, while the highest I on/I off ratio i.e. 43.8 is achieved with light illuminations. The abrupt changes in the current response due to light-on/off conditions validates these devices for fast flexible photodetector switches. These devices are also evaluated based on transfer procedure i.e. flip-over and stamp-assisted transfer printing for manipulating Si microwires and their subsequent post-processing. These new developments were made to study the most feasible approach for transfer printing of Si microwires and to harvest their capabilities such as photodetection and several other applications in the shape of metal-semiconductor-metal structures.

  19. Magnetic and structural properties of glass-coated Heusler-type microwires exhibiting martensitic transformation.

    PubMed

    Zhukov, A; Ipatov, M; Del Val, J J; Zhukova, V; Chernenko, V A

    2018-01-12

    We have studied magnetic and structural properties of the Heusler-type Ni-Mn-Ga glass-coated microwires prepared by Tailor-Ulitovsky technique. As-prepared sample presents magnetoresistance effect and considerable dependence of magnetization curves (particularly magnetization values) on magnetic field attributed to the magnetic and atomic disorder. Annealing strongly affects the temperature dependence of magnetization and Curie temperature of microwires. After annealing of the microwires at 973 K, the Curie temperature was enhanced to about 280 K which is beneficial for the magnetic solid state refrigeration. The observed hysteretic anomalies on the temperature dependences of resistance and magnetization in the as-prepared and annealed samples are produced by the martensitic transformation. The magnetoresistance and magnetocaloric effects have been investigated to illustrate a potential technological capability of studied microwires.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Ying, E-mail: yingma@imr.ac.cn; Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Science; An, Boxing

    By using an electron donor–acceptor molecule that consists of a perylenediimide (PDI) core bonded with two ferrocene (Fc) units, well-defined nanorods, nanowires and microwires of PDI-Fc were formed through simply adjusting the initial concentration of PDI-Fc in dichloromethane or CH{sub 2}Cl{sub 2}. Moreover, the two-ended devices based on individual microwire were fabricated. Highly reproducible and sensitive photo response characteristics were demonstrated in the microwire through controlling the white light on and off with different light intensities. The assembly strategy via complementary donors and acceptors is of significance for constructing photoconductive systems and developing novel functional devices. - Graphical abstract: Themore » two-ended devices based on individual microwire were fabricated. Highly reproducible and sensitive photo response characteristics were observed by controlling the white light on and off with different light intensities. - Highlights: • An electron donor–acceptor molecule (PDI-Fc) was synthesized. • Well-defined nanorods, nanowires and microwires of PDI-Fc were formed. • The two-ended devices based on individual microwire were fabricated. • Highly reproducible and sensitive photo response characteristics were observed.« less

  1. Wavelength-tunable waveguides based on polycrystalline organic-inorganic perovskite microwires

    NASA Astrophysics Data System (ADS)

    Wang, Ziyu; Liu, Jingying; Xu, Zai-Quan; Xue, Yunzhou; Jiang, Liangcong; Song, Jingchao; Huang, Fuzhi; Wang, Yusheng; Zhong, Yu Lin; Zhang, Yupeng; Cheng, Yi-Bing; Bao, Qiaoliang

    2016-03-01

    Hybrid organic-inorganic perovskites have emerged as new photovoltaic materials with impressively high power conversion efficiency due to their high optical absorption coefficient and long charge carrier diffusion length. In addition to high photoluminescence quantum efficiency and chemical tunability, hybrid organic-inorganic perovskites also show intriguing potential for diverse photonic applications. In this work, we demonstrate that polycrystalline organic-inorganic perovskite microwires can function as active optical waveguides with small propagation loss. The successful production of high quality perovskite microwires with different halogen elements enables the guiding of light with different colours. Furthermore, it is interesting to find that out-coupled light intensity from the microwire can be effectively modulated by an external electric field, which behaves as an electro-optical modulator. This finding suggests the promising applications of perovskite microwires as effective building blocks in micro/nano scale photonic circuits.

  2. Wavelength-tunable waveguides based on polycrystalline organic-inorganic perovskite microwires.

    PubMed

    Wang, Ziyu; Liu, Jingying; Xu, Zai-Quan; Xue, Yunzhou; Jiang, Liangcong; Song, Jingchao; Huang, Fuzhi; Wang, Yusheng; Zhong, Yu Lin; Zhang, Yupeng; Cheng, Yi-Bing; Bao, Qiaoliang

    2016-03-28

    Hybrid organic-inorganic perovskites have emerged as new photovoltaic materials with impressively high power conversion efficiency due to their high optical absorption coefficient and long charge carrier diffusion length. In addition to high photoluminescence quantum efficiency and chemical tunability, hybrid organic-inorganic perovskites also show intriguing potential for diverse photonic applications. In this work, we demonstrate that polycrystalline organic-inorganic perovskite microwires can function as active optical waveguides with small propagation loss. The successful production of high quality perovskite microwires with different halogen elements enables the guiding of light with different colours. Furthermore, it is interesting to find that out-coupled light intensity from the microwire can be effectively modulated by an external electric field, which behaves as an electro-optical modulator. This finding suggests the promising applications of perovskite microwires as effective building blocks in micro/nano scale photonic circuits.

  3. Large and reversible inverse magnetocaloric effect in Ni48.1Co2.9Mn35.0In14.0 metamagnetic shape memory microwire

    NASA Astrophysics Data System (ADS)

    Qu, Y. H.; Cong, D. Y.; Chen, Z.; Gui, W. Y.; Sun, X. M.; Li, S. H.; Ma, L.; Wang, Y. D.

    2017-11-01

    High-performance magnetocaloric materials should have a large reversible magnetocaloric effect and good heat exchange capability. Here, we developed a Ni48.1Co2.9Mn35.0In14.0 metamagnetic shape memory microwire with a large and reversible inverse magnetocaloric effect. As compared to the bulk counterpart, the microwire shows a better combination of magnetostructural transformation parameters (magnetization difference across transformation ΔM, transformation entropy change ΔStr, thermal hysteresis ΔThys, and transformation interval ΔTint) and thus greatly reduced critical field required for complete and reversible magnetic-field-induced transformation. A strong and reversible metamagnetic transition occurred in the microwire, which facilitates the achievement of large reversible magnetoresponsive effects. Consequently, a large and reversible magnetic-field-induced entropy change ΔSm of 12.8 J kg-1 K-1 under 5 T was achieved in the microwire, which is the highest value reported heretofore in Ni-Mn-based magnetic shape memory wires. Furthermore, since microwires have a high surface/volume ratio, they exhibit very good heat exchange capability. The present Ni48.1Co2.9Mn35.0In14.0 microwire shows great potential for magnetic refrigeration. This study may stimulate further development of high-performance magnetocaloric wires for high-efficiency and environmentally friendly solid-state cooling.

  4. Tailoring of magnetoimpedance effect and magnetic softness of Fe-rich glass-coated microwires by stress- annealing.

    PubMed

    Zhukova, V; Blanco, J M; Ipatov, M; Churyukanova, M; Taskaev, S; Zhukov, A

    2018-02-16

    There is a pressing need for improving of the high-frequency magneto-impedance effect of cost-effective soft magnetic materials for use in high-performance sensing devices. The impact of the stress-annealing on magnetic properties and high frequency impedance of Fe-rich glass-coated microwires was studied. Hysteresis loops of Fe-rich microwires have been considerably affected by stress- annealing. In stress-annealed Fe- rich microwire we obtained drastic decreasing of coercivity and change of character of hysteresis loop from rectangular to linear. By controlling stress-annealing conditions (temperature and time) we achieved drastic increasing (by order of magnitude) of giant magnetoimpedance ratio. Coercivity, remanent magnetization, diagonal and of-diagonal magnetoimpedance effect of Fe-rich microwires can be tuned by stress-annealing conditions: annealing temperature and time. Observed experimental results are discussed considering relaxation of internal stresses, compressive "back-stresses" arising after stress annealing and topological short range ordering.

  5. Highly sensitive heavy metal ion detection using AlQ3 microwire functionalized QCM

    NASA Astrophysics Data System (ADS)

    Can, Nursel; Aǧar, Meltem; Altındal, Ahmet

    2016-03-01

    Tris(8-hydroxyquinoline) aluminum (Alq3) microwires was successfully synthesized for the fabrication of Alq3 microwires-coated QCM sensors to detect the heavy metal ions in aqueous solution. AT-cut quartz crystal microbalance (QCM) of 10 MHz fundamental resonance frequency having gold electrodes were used as transducers. Typical measuring cycle consisted of repeated flow of target measurands through the flow cell and subsequent washing to return the baseline. The QCM results indicated that the Alq3 microwires exhibit excellent sensitivity, stability and short response-recovery time, which are much attractive for the development of portable and highly sensitive heavy metal ion sensors in water samples.

  6. Multi-scale recordings for neuroprosthetic control of finger movements.

    PubMed

    Baker, Justin; Bishop, William; Kellis, Spencer; Levy, Todd; House, Paul; Greger, Bradley

    2009-01-01

    We trained a rhesus monkey to perform individuated and combined finger flexions and extensions of the thumb, index, and middle finger. A Utah Electrode Array (UEA) was implanted into the hand region of the motor cortex contralateral to the monkey's trained hand. We also implanted a microwire electrocorticography grid (microECoG) epidurally so that it covered the UEA. The microECoG grid spanned the arm and hand regions of both the primary motor and somatosensory cortices. Previously this monkey had Implantable MyoElectric Sensors (IMES) surgically implanted into the finger muscles of the monkey's forearm. Action potentials (APs), local field potentials (LFPs), and microECoG signals were recorded from wired head-stage connectors for the UEA and microECoG grids, while EMG was recorded wirelessly. The monkey performed a finger flexion/extension task while neural and EMG data were acquired. We wrote an algorithm that uses the spike data from the UEA to perform a real-time decode of the monkey's finger movements. Also, analyses of the LFP and microECoG data indicate that these data show trial-averaged differences between different finger movements, indicating the data are potentially decodeable.

  7. Optimization of microwire/glass-fibre reinforced polymer composites for wind turbine application

    NASA Astrophysics Data System (ADS)

    Qin, F. X.; Peng, H. X.; Chen, Z.; Wang, H.; Zhang, J. W.; Hilton, G.

    2013-11-01

    We here report a comprehensive study of glass-fibre reinforced polymers (GFRP) incorporating ferromagnetic microwires for microwave absorption applications. With wire addition, a remarkable dependence of microwave absorption performance appears on the local properties of wires such as wire geometry and the mesostructure such as inter-wire spacing, as well as the embedded depth of the wires layer. The impact testing further demonstrates that the metallic microwires can to some extent improve the impact performance. Based on both the absorption and impact behavior, we propose an optimized design of the microwire/GFRP composites to achieve simultaneous best possible absorption and impact performance for multifunctional applications in aeronautical structures and wind turbines.

  8. Excellent magnetocaloric properties of melt-extracted Gd-based amorphous microwires

    NASA Astrophysics Data System (ADS)

    Bingham, N. S.; Wang, H.; Qin, F.; Peng, H. X.; Sun, J. F.; Franco, V.; Srikanth, H.; Phan, M. H.

    2012-09-01

    We report upon the excellent magnetocaloric properties of Gd53Al24Co20Zr3 amorphous microwires. In addition to obtaining the large magnetic entropy change (-ΔSM ˜ 10.3 J/kg K at TC ˜ 95 K), an extremely large value of refrigerant capacity (RC ˜ 733.4 J/kg) has been achieved for a field change of 5 T in an array of forty microwires arranged in parallel. This value of RC is about 79% and 103% larger than those of Gd (˜410 J/kg) and Gd5Si2Ge1.9Fe0.1 (˜360 J/kg) regardless of their magnetic ordering temperatures. The design and fabrication of a magnetic bed made of these parallel-arranged microwires would thus be a very promising approach for active magnetic refrigeration for nitrogen liquefaction. Since these microwires can easily be assembled as laminate structures, they have potential applications as a cooling device for micro electro mechanical systems and nano electro mechanical systems.

  9. The sinusoidal probe: a new approach to improve electrode longevity

    PubMed Central

    Sohal, Harbaljit S.; Jackson, Andrew; Jackson, Richard; Clowry, Gavin J.; Vassilevski, Konstantin; O’Neill, Anthony; Baker, Stuart N.

    2014-01-01

    Micromotion between the brain and implanted electrodes is a major contributor to the failure of invasive brain–machine interfaces. Movements of the electrode tip cause recording instabilities while spike amplitudes decline over the weeks/months post-implantation due to glial cell activation caused by sustained mechanical trauma. We have designed a sinusoidal probe in order to reduce movement of the recording tip relative to the surrounding neural tissue. The probe was microfabricated from flexible materials and incorporated a sinusoidal shaft to minimize tethering forces and a 3D spheroid tip to anchor the recording site within the brain. Compared to standard microwire electrodes, the signal-to-noise ratio and local field potential power of sinusoidal probe recordings from rabbits was more stable across recording periods up to 678 days. Histological quantification of microglia and astrocytes showed reduced neuronal tissue damage especially for the tip region between 6 and 24 months post-implantation. We suggest that the micromotion-reducing measures incorporated into our design, at least partially, decreased the magnitude of gliosis, resulting in enhanced longevity of recording. PMID:24808859

  10. Synthesis of Au microwires by selective oxidation of Au–W thin-film composition spreads

    PubMed Central

    Hamann, Sven; Brunken, Hayo; Salomon, Steffen; Meyer, Robert; Savan, Alan; Ludwig, Alfred

    2013-01-01

    We report on the stress-induced growth of Au microwires out of a surrounding Au–W matrix by selective oxidation, in view of a possible application as ‘micro-Velcro’. The Au wires are extruded due to the high compressive stress in the tungsten oxide formed by oxidation of elemental W. The samples were fabricated as a thin-film materials library using combinatorial sputter deposition followed by thermal oxidation. Sizes and shapes of the Au microwires were investigated as a function of the W to Au ratio. The coherence length and stress state of the Au microwires were related to their shape and plastic deformation. Depending on the composition of the Au–W precursor, the oxidized samples showed regions with differently shaped Au microwires. The Au48W52 composition yielded wires with the maximum length to diameter ratio due to the high compressive stress in the tungsten oxide matrix. The values of wire length (35 μm) and diameter (2 μm) achieved at the Au48W52 composition are suitable for micro-Velcro applications. PMID:27877561

  11. Versatile control of metal-assisted chemical etching for vertical silicon microwire arrays and their photovoltaic applications

    PubMed Central

    Um, Han-Don; Kim, Namwoo; Lee, Kangmin; Hwang, Inchan; Hoon Seo, Ji; Yu, Young J.; Duane, Peter; Wober, Munib; Seo, Kwanyong

    2015-01-01

    A systematic study was conducted into the use of metal-assisted chemical etching (MacEtch) to fabricate vertical Si microwire arrays, with several models being studied for the efficient redox reaction of reactants with silicon through a metal catalyst by varying such parameters as the thickness and morphology of the metal film. By optimizing the MacEtch conditions, high-quality vertical Si microwires were successfully fabricated with lengths of up to 23.2 μm, which, when applied in a solar cell, achieved a conversion efficiency of up to 13.0%. These solar cells also exhibited an open-circuit voltage of 547.7 mV, a short-circuit current density of 33.2 mA/cm2, and a fill factor of 71.3% by virtue of the enhanced light absorption and effective carrier collection provided by the Si microwires. The use of MacEtch to fabricate high-quality Si microwires therefore presents a unique opportunity to develop cost-effective and highly efficient solar cells. PMID:26060095

  12. Study on the shrinkage behavior and conductivity of silver microwires during electrostatic field assisted sintering

    NASA Astrophysics Data System (ADS)

    Shangguan, Lei; Ma, Liuhong; Li, Mengke; Peng, Wei; Zhong, Yinghui; Su, Yufeng; Duan, Zhiyong

    2018-05-01

    An electrostatic field was applied to sintering Ag microwires to achieve a more compact structure and better conductivity. The shrinkage behavior of Ag microwires shows anisotropy, since bigger particle sizes, less micropores and smoother surfaces were observed in the direction of the electrostatic field in comparsion with the direction perpendicular to the electrostatic field, and the shrinkage rate of Ag microwires in the direction of electrostatic field improves about 2.4% with the electrostatic field intensity of 800 V cm‑1. The electrostatic field assisted sintering model of Ag microwires is proposed according to thermal diffuse dynamics analysis and experimental research. Moreover, the grain size of Ag microwres sintered with electrostatic field increases with the electrostatic field intensity and reaches 113 nm when the electrostatic field intensity is 800 V cm‑1, and the resistivity decreases to 2.07  ×  10‑8 Ω m as well. This method may overcome the restriction of metal wires which fabricated by the pseudoplastic metal nanoparticle fluid and be used as interconnects in nanoimprint lithography.

  13. Giant magneto-impedance and stress-impedance effects of microwire composites for sensing applications

    NASA Astrophysics Data System (ADS)

    Qin, F. X.; Peng, H. X.; Popov, V. V.; Phan, M. H.

    2011-02-01

    Composites consisting of glass-coated amorphous microwire Co 68.59Fe 4.84Si 12.41B 14.16 and 913 E-glass prepregs were designed and fabricated. The influences of tensile stress, annealing and number of composite layers on the giant magneto-impedance (GMI) and giant stress-impedance (GSI) effects in these composites were investigated systematically. It was found that the application of tensile stress along the microwire axis or an increase in the number of composite layers reduced the GMI effect and increased the circular anisotropy field, while the annealing treatment had a reverse effect. The value of matrix-wire interfacial stress calculated via the GMI profiles coincided with the value of the applied effective tensile stress to yield similar GMI profiles. Enhancement of the GSI effect was achieved in the composites relative to their single microwire inclusion. These findings are important for the development of functional microwire-based composites for magnetic- and stress-sensing applications. They also open up a new route for probing the interfacial stress in fibre-reinforced polymer (FRP) composites.

  14. CoFe-microwires with stress-dependent magnetostriction as embedded sensing elements

    NASA Astrophysics Data System (ADS)

    Salem, M. M.; Nematov, M. G.; Uddin, A.; Panina, L. V.; Churyukanova, M. N.; Marchenko, A. T.

    2017-10-01

    Testing internal stress/strain condition of polymer composite materials is of high importance in structural health monitoring. We are presenting here a new method of monitoring internal stresses. The method can be referred to as embedded sensing technique, where the sensing element is a glass-coated ferromagnetic microwire with a specific magnetic anisotropy and stress-dependent magnetostriction. When the microwire is remagnetized the sharp voltage is induced which is characterized by high frequency harmonics. The amplitude of these harmonics sensitively depends on various stresses. The microwire of composition Co71Fe5B11Si10Cr3 with the metallic core diameter of 22.8 μm show abrupt transformation of the magnetization process under applied tensile stress owing to the stress-dependent magnetostriction.

  15. Strain induced on (TMTSF){2}ReO{4} microwires deposited on a silicon substrate

    NASA Astrophysics Data System (ADS)

    Colin, C. V.; Joo, N.; Pasquier, C. R.

    2009-12-01

    We present the successful recrystallization of Bechgaard salts with the microwire shape using the drop casting method. The samples are deposited on a substrate with previously prepared patterns made by optical lithography. The physical properties of the microwires are shown. The excellent transport properties show that this technique provides a new method for the tuning of the physical properties of molecular conductors and the first step toward applications. The pressure effects of the substrate on the conduction are discussed.

  16. Microengineering Laser Plasma Interactions at Relativistic Intensities.

    PubMed

    Jiang, S; Ji, L L; Audesirk, H; George, K M; Snyder, J; Krygier, A; Poole, P; Willis, C; Daskalova, R; Chowdhury, E; Lewis, N S; Schumacher, D W; Pukhov, A; Freeman, R R; Akli, K U

    2016-02-26

    We report on the first successful proof-of-principle experiment to manipulate laser-matter interactions on microscales using highly ordered Si microwire arrays. The interaction of a high-contrast short-pulse laser with a flat target via periodic Si microwires yields a substantial enhancement in both the total and cutoff energies of the produced electron beam. The self-generated electric and magnetic fields behave as an electromagnetic lens that confines and guides electrons between the microwires as they acquire relativistic energies via direct laser acceleration.

  17. Microengineering Laser Plasma Interactions at Relativistic Intensities

    NASA Astrophysics Data System (ADS)

    Jiang, S.; Ji, L. L.; Audesirk, H.; George, K. M.; Snyder, J.; Krygier, A.; Poole, P.; Willis, C.; Daskalova, R.; Chowdhury, E.; Lewis, N. S.; Schumacher, D. W.; Pukhov, A.; Freeman, R. R.; Akli, K. U.

    2016-02-01

    We report on the first successful proof-of-principle experiment to manipulate laser-matter interactions on microscales using highly ordered Si microwire arrays. The interaction of a high-contrast short-pulse laser with a flat target via periodic Si microwires yields a substantial enhancement in both the total and cutoff energies of the produced electron beam. The self-generated electric and magnetic fields behave as an electromagnetic lens that confines and guides electrons between the microwires as they acquire relativistic energies via direct laser acceleration.

  18. Nanowire and microwire fabrication technique and product

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sumant, Anirudha V.; Zach, Michael; Marten, Alan David

    A continuous or semi-continuous process for fabricating nanowires or microwires makes use of the substantially planar template that may be moved through electrochemical solution to grow nanowires or microwires on exposed conductive edges on the surface of that template. The planar template allows fabrication of the template using standard equipment and techniques. Adhesive transfer may be used to remove the wires from the template and in one embodiment to draw a continuous wire from the template to be wound around the drum.

  19. First-order martensitic transformation in Heusler-type glass-coated microwires

    NASA Astrophysics Data System (ADS)

    Zhukov, A.; Ipatov, M.; del Val, J. J.; Taskaev, S.; Churyukanova, M.; Zhukova, V.

    2017-12-01

    Properly annealed Ni-Mn-Ga glass-covered microwires exhibit a hysteretic anomaly on the temperature dependence of magnetization attributed to the first order martensitic transformation. The temperatures of the structural and magnetic transitions are drastically affected by annealing conditions. Annealed glass-coated Ni-Mn-Ga microwires show a Curie temperature shift close to room temperature. The temperature and magnetic field dependences of magnetization are discussed in terms of atomic disorder, the release of internal stresses, and recrystallization after annealing.

  20. In-plane omnidirectional magnetic field sensor based on Giant Magneto Impedance (GMI)

    NASA Astrophysics Data System (ADS)

    Díaz-Rubio, Ana; García-Miquel, Héctor; García-Chocano, Víctor Manuel

    2017-12-01

    In this work the design and characterization of an omnidirectional in-plane magnetic field sensor are presented. The sensor is based on the Giant Magneto Impedance (GMI) effect in glass-coated amorphous microwires of composition (Fe6Co94)72.5Si12.5B15. For the first time, a circular loop made with a microwire is used for giving omnidirectional response. In order to estimate the GMI response of the circular loop we have used a theoretical model of GMI, determining the GMI response as the sum of longitudinal sections with different angles of incidence. As a consequence of the circular loop, the GMI ratio of the sensor is reduced to 15% instead of 100% for the axial GMI response of a microwire. The sensor response has been experimentally verified and the GMI response of the circular loop has been studied as function of the magnetic field, driven current, and frequency. First, we have measured the GMI response of a longitudinal microwire for different angles of incidence, covering the full range between the tangential and perpendicular directions to the microwire axis. Then, using these results, we have experimentally verified the decomposition of a microwire with circular shape as longitudinal segments with different angles of incidence. Finally, we have designed a signal conditioning circuit for the omnidirectional magnetic field sensor. The response of the sensor has been studied as a function of the amplitude of the incident magnetic field.

  1. Tuning Metamaterials by using Amorphous Magnetic Microwires

    NASA Astrophysics Data System (ADS)

    Lopez-Dominguez, Victor; Garcia, Miguel Angel; Marin, Pilar; Hernando, Antonio

    Tuning the electromagnetic properties of metamaterials using external stimulus result appealing for both, fundamental and applied reasons. Little work has been developed in the tuning of the properties of a metamaterial by magnetic fields. The main reason relies on the fact that most magnetic materials tale off their response at the microwave band, or they are moderately active only at their Ferromagnetic Resonance, as it is the case of ferrites. These limitations can be overcome using Co-based Magnetic microwires with a quasi-zero magnetostriction that leads to a high permeability at microwave frequencies. The inclusion of magnetic microwires in a metamaterial type Split Ring Resonator array (SRR) allows tuning their electromagnetic properties with low magnetic fields. The results clearly show an effective tune of the S-coefficients up-to 8 dB using 100 microwires per SRR for DC fields between 0 and 20 Oe.

  2. COMMUNICATION: Electrophysiological response dynamics during focal cortical infarction

    NASA Astrophysics Data System (ADS)

    Chiganos, Terry C., Jr.; Jensen, Winnie; Rousche, Patrick J.

    2006-12-01

    While the intracellular processes of hypoxia-induced necrosis and the intercellular mechanisms of post-ischemic neurotoxicity associated with stroke are well documented, the dynamic electrophysiological (EP) response of neurons within the core or periinfarct zone remains unclear. The present study validates a method for continuous measurement of the local EP responses during focal cortical infarction induced via photothrombosis. Single microwire electrodes were acutely implanted into the primary auditory cortex of eight rats. Multi-unit neural activity, evoked via a continuous 2 Hz click stimulus, was recorded before, during and after infarction to assess neuronal function in response to local, permanent ischemia. During sham infarction, the average stimulus-evoked peak firing rate over 20 min remained stable at 495.5 ± 14.5 spikes s-1, indicating temporal stability of neural function under normal conditions. Stimulus-evoked peak firing was reliably reduced to background levels (firing frequency in the absence of stimulus) following initiation of photothrombosis over a period of 439 ± 92 s. The post-infarction firing patterns exhibited unique temporal degradation of the peak firing rate, suggesting a variable response to ischemic challenge. Despite the inherent complexity of cerebral ischemia secondary to microvascular occlusion, complete loss of EP function consistently occurred 300-600 s after photothrombosis. The results suggest that microwire recording during photothrombosis provides a simple and highly efficacious strategy for assessing the electrophysiological dynamics of cortical infarction.

  3. Face-selective neurons maintain consistent visual responses across months

    PubMed Central

    McMahon, David B. T.; Jones, Adam P.; Bondar, Igor V.; Leopold, David A.

    2014-01-01

    Face perception in both humans and monkeys is thought to depend on neurons clustered in discrete, specialized brain regions. Because primates are frequently called upon to recognize and remember new individuals, the neuronal representation of faces in the brain might be expected to change over time. The functional properties of neurons in behaving animals are typically assessed over time periods ranging from minutes to hours, which amounts to a snapshot compared to a lifespan of a neuron. It therefore remains unclear how neuronal properties observed on a given day predict that same neuron's activity months or years later. Here we show that the macaque inferotemporal cortex contains face-selective cells that show virtually no change in their patterns of visual responses over time periods as long as one year. Using chronically implanted microwire electrodes guided by functional MRI targeting, we obtained distinct profiles of selectivity for face and nonface stimuli that served as fingerprints for individual neurons in the anterior fundus (AF) face patch within the superior temporal sulcus. Longitudinal tracking over a series of daily recording sessions revealed that face-selective neurons maintain consistent visual response profiles across months-long time spans despite the influence of ongoing daily experience. We propose that neurons in the AF face patch are specialized for aspects of face perception that demand stability as opposed to plasticity. PMID:24799679

  4. Face-selective neurons maintain consistent visual responses across months.

    PubMed

    McMahon, David B T; Jones, Adam P; Bondar, Igor V; Leopold, David A

    2014-06-03

    Face perception in both humans and monkeys is thought to depend on neurons clustered in discrete, specialized brain regions. Because primates are frequently called upon to recognize and remember new individuals, the neuronal representation of faces in the brain might be expected to change over time. The functional properties of neurons in behaving animals are typically assessed over time periods ranging from minutes to hours, which amounts to a snapshot compared to a lifespan of a neuron. It therefore remains unclear how neuronal properties observed on a given day predict that same neuron's activity months or years later. Here we show that the macaque inferotemporal cortex contains face-selective cells that show virtually no change in their patterns of visual responses over time periods as long as one year. Using chronically implanted microwire electrodes guided by functional MRI targeting, we obtained distinct profiles of selectivity for face and nonface stimuli that served as fingerprints for individual neurons in the anterior fundus (AF) face patch within the superior temporal sulcus. Longitudinal tracking over a series of daily recording sessions revealed that face-selective neurons maintain consistent visual response profiles across months-long time spans despite the influence of ongoing daily experience. We propose that neurons in the AF face patch are specialized for aspects of face perception that demand stability as opposed to plasticity.

  5. Visible cathodoluminescence of Er ions in β-Ga(2)O(3) nanowires and microwires.

    PubMed

    Nogales, E; Méndez, B; Piqueras, J

    2008-01-23

    Erbium doped β-Ga(2)O(3) nanowires and microwires have been obtained by a vapour-solid process from an initial mixture of Ga(2)O(3) and Er(2)O(3) powders. X-ray diffraction (XRD) analysis reveals the presence of erbium gallium garnet as well as β-Ga(2)O(3) phases in the microwires. Scanning electron microscopy (SEM) images show that the larger microwires have a nearly rectangular cross-section. Transmission electron microscopy (TEM) and high-resolution TEM (HRTEM) analysis show good crystal quality of the β-Ga(2)O(3) nanowires. The nanostructures have been studied by means of the cathodoluminescence technique in the scanning electron microscope. Er intraionic blue, green and red emission lines are observed in luminescence spectra even at room temperature, which confirms the optical activity of the rare earth ions in the grown structures. Mapping of the main 555 nm emission intensity shows a non-homogeneous distribution of Er ions in the microstructures.

  6. Piezo-phototronic effect enhanced UV photodetector based on CuI/ZnO double-shell grown on flexible copper microwire.

    PubMed

    Liu, Jingyu; Zhang, Yang; Liu, Caihong; Peng, Mingzeng; Yu, Aifang; Kou, Jinzong; Liu, Wei; Zhai, Junyi; Liu, Juan

    2016-12-01

    In this work, we present a facile, low-cost, and effective approach to fabricate the UV photodetector with a CuI/ZnO double-shell nanostructure which was grown on common copper microwire. The enhanced performances of Cu/CuI/ZnO core/double-shell microwire photodetector resulted from the formation of heterojunction. Benefiting from the piezo-phototronic effect, the presentation of piezocharges can lower the barrier height and facilitate the charge transport across heterojunction. The photosensing abilities of the Cu/CuI/ZnO core/double-shell microwire detector are investigated under different UV light densities and strain conditions. We demonstrate the I-V characteristic of the as-prepared core/double-shell device; it is quite sensitive to applied strain, which indicates that the piezo-phototronic effect plays an essential role in facilitating charge carrier transport across the CuI/ZnO heterojunction, then the performance of the device is further boosted under external strain.

  7. Efficient and Stable Silicon Microwire Photocathodes with a Nickel Silicide Interlayer for Operation in Strongly Alkaline Solutions.

    PubMed

    Vijselaar, Wouter; Tiggelaar, Roald M; Gardeniers, Han; Huskens, Jurriaan

    2018-05-11

    Most photoanodes commonly applied in solar fuel research (e.g., of Fe 2 O 3 , BiVO 4 , TiO 2 , or WO 3 ) are only active and stable in alkaline electrolytes. Silicon (Si)-based photocathodes on the other hand are mainly studied under acidic conditions due to their instability in alkaline electrolytes. Here, we show that the in-diffusion of nickel into a 3D Si structure, upon thermal annealing, yields a thin (sub-100 nm), defect-free nickel silicide (NiSi) layer. This has allowed us to design and fabricate a Si microwire photocathode with a NiSi interlayer between the catalyst and the Si microwires. Upon electrodeposition of the catalyst (here, nickel molybdenum) on top of the NiSi layer, an efficient, Si-based photocathode was obtained that is stable in strongly alkaline solutions (1 M KOH). The best-performing, all-earth-abundant microwire array devices exhibited, under AM 1.5G simulated solar illumination, an ideal regenerative cell efficiency of 10.1%.

  8. Emily Warren | NREL

    Science.gov Websites

    generators. Featured Publications Warren, E. L.; Atwater, H. A.; Lewis, N. S. "Silicon Microwire Arrays , (2013) Warren, E. L.; McKone, J. R.; Atwater, H. A.; Gray, H. B.; Lewis, N. S. "Hydrogen-Evolution Characteristics of Ni-Mo-Coated, Radial Junction, n+p-silicon Microwire Array Photocathodes," Energy &

  9. Ferromagnetic glass-coated microwires with good heating properties for magnetic hyperthermia

    DOE PAGES

    Talaat, A.; Alonso, J.; Zhukova, V.; ...

    2016-12-01

    The heating properties of Fe 71.7Si 11B 13.4Nb 3Ni 0.9 amorphous glass-coated microwires are explored for prospective applications in magnetic hyperthermia. We show that a single 5 mm long wire is able to produce a sufficient amount of heat, with the specific loss power (SLP) reaching a value as high as 521 W/g for an AC field of 700 Oe and a frequency of 310 kHz. The large SLP is attributed to the rectangular hysteresis loop resulting from a peculiar domain structure of the microwire. For an array of parallel microwires, we have observed an SLP improvement by one ordermore » of magnitude; 950 W/g for an AC field of 700 Oe. The magnetostatic interaction strength essential in the array of wires can be manipulated by varying the distance between the wires, showing a decreasing trend in SLP with increasing wire separation. The largest SLP is obtained when the wires are aligned along the direction of the AC field. The origin of the large SLP and relevant heating mechanisms are discussed.« less

  10. Ferromagnetic glass-coated microwires with good heating properties for magnetic hyperthermia

    NASA Astrophysics Data System (ADS)

    Talaat, A.; Alonso, J.; Zhukova, V.; Garaio, E.; García, J. A.; Srikanth, H.; Phan, M. H.; Zhukov, A.

    2016-12-01

    The heating properties of Fe71.7Si11B13.4Nb3Ni0.9 amorphous glass-coated microwires are explored for prospective applications in magnetic hyperthermia. We show that a single 5 mm long wire is able to produce a sufficient amount of heat, with the specific loss power (SLP) reaching a value as high as 521 W/g for an AC field of 700 Oe and a frequency of 310 kHz. The large SLP is attributed to the rectangular hysteresis loop resulting from a peculiar domain structure of the microwire. For an array of parallel microwires, we have observed an SLP improvement by one order of magnitude; 950 W/g for an AC field of 700 Oe. The magnetostatic interaction strength essential in the array of wires can be manipulated by varying the distance between the wires, showing a decreasing trend in SLP with increasing wire separation. The largest SLP is obtained when the wires are aligned along the direction of the AC field. The origin of the large SLP and relevant heating mechanisms are discussed.

  11. Ferromagnetic glass-coated microwires with good heating properties for magnetic hyperthermia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talaat, A.; Alonso, J.; Zhukova, V.

    The heating properties of Fe 71.7Si 11B 13.4Nb 3Ni 0.9 amorphous glass-coated microwires are explored for prospective applications in magnetic hyperthermia. We show that a single 5 mm long wire is able to produce a sufficient amount of heat, with the specific loss power (SLP) reaching a value as high as 521 W/g for an AC field of 700 Oe and a frequency of 310 kHz. The large SLP is attributed to the rectangular hysteresis loop resulting from a peculiar domain structure of the microwire. For an array of parallel microwires, we have observed an SLP improvement by one ordermore » of magnitude; 950 W/g for an AC field of 700 Oe. The magnetostatic interaction strength essential in the array of wires can be manipulated by varying the distance between the wires, showing a decreasing trend in SLP with increasing wire separation. The largest SLP is obtained when the wires are aligned along the direction of the AC field. The origin of the large SLP and relevant heating mechanisms are discussed.« less

  12. Ferromagnetic glass-coated microwires with good heating properties for magnetic hyperthermia

    PubMed Central

    Talaat, A.; Alonso, J.; Zhukova, V.; Garaio, E.; García, J. A.; Srikanth, H.; Phan, M. H.; Zhukov, A.

    2016-01-01

    The heating properties of Fe71.7Si11B13.4Nb3Ni0.9 amorphous glass-coated microwires are explored for prospective applications in magnetic hyperthermia. We show that a single 5 mm long wire is able to produce a sufficient amount of heat, with the specific loss power (SLP) reaching a value as high as 521 W/g for an AC field of 700 Oe and a frequency of 310 kHz. The large SLP is attributed to the rectangular hysteresis loop resulting from a peculiar domain structure of the microwire. For an array of parallel microwires, we have observed an SLP improvement by one order of magnitude; 950 W/g for an AC field of 700 Oe. The magnetostatic interaction strength essential in the array of wires can be manipulated by varying the distance between the wires, showing a decreasing trend in SLP with increasing wire separation. The largest SLP is obtained when the wires are aligned along the direction of the AC field. The origin of the large SLP and relevant heating mechanisms are discussed. PMID:27991557

  13. Spatial decoupling of light absorption and catalytic activity of Ni-Mo-loaded high-aspect-ratio silicon microwire photocathodes

    NASA Astrophysics Data System (ADS)

    Vijselaar, Wouter; Westerik, Pieter; Veerbeek, Janneke; Tiggelaar, Roald M.; Berenschot, Erwin; Tas, Niels R.; Gardeniers, Han; Huskens, Jurriaan

    2018-03-01

    A solar-driven photoelectrochemical cell provides a promising approach to enable the large-scale conversion and storage of solar energy, but requires the use of Earth-abundant materials. Earth-abundant catalysts for the hydrogen evolution reaction, for example nickel-molybdenum (Ni-Mo), are generally opaque and require high mass loading to obtain high catalytic activity, which in turn leads to parasitic light absorption for the underlying photoabsorber (for example silicon), thus limiting production of hydrogen. Here, we show the fabrication of a highly efficient photocathode by spatially and functionally decoupling light absorption and catalytic activity. Varying the fraction of catalyst coverage over the microwires, and the pitch between the microwires, makes it possible to deconvolute the contributions of catalytic activity and light absorption to the overall device performance. This approach provided a silicon microwire photocathode that exhibited a near-ideal short-circuit photocurrent density of 35.5 mA cm-2, a photovoltage of 495 mV and a fill factor of 62% under AM 1.5G illumination, resulting in an ideal regenerative cell efficiency of 10.8%.

  14. Efficient and Stable Silicon Microwire Photocathodes with a Nickel Silicide Interlayer for Operation in Strongly Alkaline Solutions

    PubMed Central

    2018-01-01

    Most photoanodes commonly applied in solar fuel research (e.g., of Fe2O3, BiVO4, TiO2, or WO3) are only active and stable in alkaline electrolytes. Silicon (Si)-based photocathodes on the other hand are mainly studied under acidic conditions due to their instability in alkaline electrolytes. Here, we show that the in-diffusion of nickel into a 3D Si structure, upon thermal annealing, yields a thin (sub-100 nm), defect-free nickel silicide (NiSi) layer. This has allowed us to design and fabricate a Si microwire photocathode with a NiSi interlayer between the catalyst and the Si microwires. Upon electrodeposition of the catalyst (here, nickel molybdenum) on top of the NiSi layer, an efficient, Si-based photocathode was obtained that is stable in strongly alkaline solutions (1 M KOH). The best-performing, all-earth-abundant microwire array devices exhibited, under AM 1.5G simulated solar illumination, an ideal regenerative cell efficiency of 10.1%. PMID:29780886

  15. Monocrystalline Heusler Co2FeSi alloy glass-coated microwires: Fabrication and magneto-structural characterization

    NASA Astrophysics Data System (ADS)

    Galdun, L.; Ryba, T.; Prida, V. M.; Zhukova, V.; Zhukov, A.; Diko, P.; Kavečanský, V.; Vargova, Z.; Varga, R.

    2018-05-01

    Large scale production of single crystalline phase of Heusler Co2FeSi alloy microwire is reported. The long microwire (∼1 km) with the metallic nucleus diameter of about 2 μm is characterized by well oriented monocrystalline structure (B2 phase, with the lattice parameter a = 5.615 Å). Moreover, the crystallographic direction [1 0 1] is parallel to the wire's axis along the entire length. Additionally, the wire is characterized by exhibiting a high Curie temperature (Tc > 800 K) and well-defined magnetic anisotropy mainly governed by shape. Electrical resistivity measurement reveals the exponential suppression of the electron-magnon scattering which provides strong evidence on the half-metallic behaviour of this material in the low temperature range.

  16. Comparison of Subgingival and Peri-implant Microbiome in Chronic Periodontitis.

    PubMed

    Zhang, Qian; Qin, Xue Yan; Jiang, Wei Peng; Zheng, Hui; Xu, Xin Li; Chen, Feng

    2015-09-01

    To analyse the microbia composition of 10 healthy dental implants and 10 chronic periodontitis patients. Subgingival plaque and peri-implant biofilm were sampled at the first molar site before and after implant restoration. The analysis was conducted by 454-prosequencing of bacterial V1 to V3 regions of 16S rDNA. Chronic periodontitis subjects showed greater bacterial diversity compared with implant subjects. The relative abundance of sixteen genera and twelve species differed significantly between implant and chronic periodontitis subjects. The genera Catonella, Desulfovibrio, Mogibacterium, Peptostreptococcus and Propionibacterium were present in higher abundance in chronic periodontitis subjects, while implant subjects had higher proportions of Brevundimonas and Pseudomonas species. Our results demonstrate that implant restoration changes the oral microbiota. The analysis suggests that periodontal bacteria can remain for a prolonged period of time at non-dental sites, from where they can colonise the peri-implant.

  17. Different contribution of BRINP3 gene in chronic periodontitis and peri-implantitis: a cross-sectional study.

    PubMed

    Casado, Priscila L; Aguiar, Diego P; Costa, Lucas C; Fonseca, Marcos A; Vieira, Thays C S; Alvim-Pereira, Claudia C K; Alvim-Pereira, Fabiano; Deeley, Kathleen; Granjeiro, José M; Trevilatto, Paula C; Vieira, Alexandre R

    2015-03-11

    Peri-implantitis is a chronic inflammation, resulting in loss of supporting bone around implants. Chronic periodontitis is a risk indicator for implant failure. Both diseases have a common etiology regarding inflammatory destructive response. BRINP3 gene is associated with aggressive periodontitis. However, is still unclear if chronic periodontitis and peri-implantitis have the same genetic background. The aim of this work was to investigate the association between BRINP3 genetic variation (rs1342913 and rs1935881) and expression and susceptibility to both diseases. Periodontal and peri-implant examinations were performed in 215 subjects, divided into: healthy (without chronic periodontitis and peri-implantitis, n = 93); diseased (with chronic periodontitis and peri-implantitis, n = 52); chronic periodontitis only (n = 36), and peri-implantitis only (n = 34). A replication sample of 92 subjects who lost implants and 185 subjects successfully treated with implants were tested. DNA was extracted from buccal cells. Two genetic markers of BRINP3 (rs1342913 and rs1935881) were genotyped using TaqMan chemistry. Chi-square (p < 0.05) compared genotype and allele frequency between groups. A subset of subjects (n = 31) had gingival biopsies harvested. The BRINP3 mRNA levels were studied by CT method (2(ΔΔCT)). Mann-Whitney test correlated the levels of BRINP3 in each group (p < 0.05). Statistically significant association between BRINP3 rs1342913 and peri-implantitis was found in both studied groups (p = 0.04). The levels of BRINP3 mRNA were significantly higher in diseased subjects compared to healthy individuals (p = 0.01). This study provides evidence that the BRINP3 polymorphic variant rs1342913 and low level of BRINP3 expression are associated with peri-implantitis, independently from the presence of chronic periodontitis.

  18. The influence of annealing on domain wall propagation in bistable amorphous microwire with unidirectional effect

    NASA Astrophysics Data System (ADS)

    Onufer, Jozef; Ziman, Ján; Duranka, Peter; Kladivová, Mária

    2018-07-01

    The effect of gradual annealing on the domain wall mobility (velocity), nucleation, critical depinning and propagation fields in amorphous FeSiB microwires has been studied. A new experimental set-up, presented in this paper, allows measurement of average domain wall velocity for four different conditions and detection of the presence of unidirectional effect in wall propagation without manipulation of the microwire. The proposed interpretation is that a domain wall is considered as a relatively long object which can change its axial dimension due to inhomogeneity of damping forces acting on the wall during its propagation. It is demonstrated that unidirectional effect in domain wall propagation can be strongly reduced by annealing the wire at temperatures higher than 350 °C.

  19. Toward a distributed free-floating wireless implantable neural recording system.

    PubMed

    Pyungwoo Yeon; Xingyuan Tong; Byunghun Lee; Mirbozorgi, Abdollah; Ash, Bruce; Eckhardt, Helmut; Ghovanloo, Maysam

    2016-08-01

    To understand the complex correlations between neural networks across different regions in the brain and their functions at high spatiotemporal resolution, a tool is needed for obtaining long-term single unit activity (SUA) across the entire brain area. The concept and preliminary design of a distributed free-floating wireless implantable neural recording (FF-WINeR) system are presented, which can enabling SUA acquisition by dispersedly implanting tens to hundreds of untethered 1 mm3 neural recording probes, floating with the brain and operating wirelessly across the cortical surface. For powering FF-WINeR probes, a 3-coil link with an intermediate high-Q resonator provides a minimum S21 of -22.22 dB (in the body medium) and -21.23 dB (in air) at 2.8 cm coil separation, which translates to 0.76%/759 μW and 0.6%/604 μW of power transfer efficiency (PTE) / power delivered to a 9 kΩ load (PDL), in body and air, respectively. A mock-up FF-WINeR is implemented to explore microassembly method of the 1×1 mm2 micromachined silicon die with a bonding wire-wound coil and a tungsten micro-wire electrode. Circuit design methods to fit the active circuitry in only 0.96 mm2 of die area in a 130 nm standard CMOS process, and satisfy the strict power and performance requirements (in simulations) are discussed.

  20. Mammalian Odor Information Recognition by Implanted Microsensor Array in vivo

    NASA Astrophysics Data System (ADS)

    Zhou, Jun; Dong, Qi; Zhuang, Liujing; Liu, Qingjun; Wang, Ping

    2011-09-01

    The mammalian olfactory system has an exquisite capacity to rapidly recognize and discriminate thousands of distinct odors in our environment. Our research group focus on reading information from olfactory bulb circuit of anethetized Sprague-Dawley rat and utilize artificial recognition system for odor discrimination. After being stimulated by three odors with concentration of 10 μM to rat nose, the response of mitral cells in olfactory bulb is recorded by eight channel microwire sensor array. In 20 sessions with 3 animals, we obtained 30 discriminated individual cells recordings. The average firing rates of the cells are Isoamyl acetate 26 Hz, Methoxybenzene 16 Hz, and Rose essential oil 11 Hz. By spike sorting, we detect peaks and analyze the interspike interval distribution. Further more, principal component analysis is applied to reduce the dimensionality of the data sets and classify the response.

  1. Reduced Dimensionality Effects in Gd-based Magnetocaloric Materials

    NASA Astrophysics Data System (ADS)

    Belliveau, Hillary

    Magnetic refrigeration based on the magnetocaloric effect (MCE) is a promising alternative to conventional gas compression based cooling techniques. Understanding impacts of reduced dimensionality on the magnetocaloric response of a material such as Gadolinium (Gd) or its alloys is essential in optimizing the performance of cooling devices, which is also the overall goal of this thesis. We have determined, in the first part of the thesis, that laminate structures of pure Gd produced by magnetron sputtering have several disadvantages. The target material (pure Gd), ultra-high vacuum components, and the electrical energy it takes to run the manufacturing process are all very costly. To produce quality films requires a time and energy consuming chamber preparation (gettering) to produce films with a relative cooling power (RCP) of an order of magnitude smaller (˜70 J/kg) than can be obtained with Gd-alloy microwires (˜800 J/kg). The increased surface area for an array of wires as compared to a laminate structure allows for more efficient heat transfer. For all of these reasons, we turned the focus onto Gd-alloy microwires. In the latter part of this thesis, we have discussed the Gd-alloy microwires as a function of magnetocaloric parameters of magnetic entropy change, adiabatic temperature change, and refrigerant capacity ( RC). We have demonstrated two effective methods for improving the RC of the microwires through creating novel biphase nanocrystalline/amorphous structures via thermal annealing and directly from adjusted melt-extraction. Through studying the effects of chemical doping, as well as studying arrays of microwires with a range of Curie temperature (TC) values, we have designed a new magnetic bed structure that has potential applications as a cooling device for micro-electro-mechanical systems and energy-conversion devices.

  2. Halting the fuse discharge propagation using optical fiber microwires.

    PubMed

    Rocha, A M; Fernandes, G; Domingues, F; Niehus, M; Pinto, A N; Facão, M; André, P S

    2012-09-10

    We report and analyze the halting of the fuse effect propagation in optical fiber microwires. The increase of the mode field diameter in the tapered region decreases the optical intensity resulting in the extinction of the fuse effect. This fiber element presents a low insertion loss and can be introduced in the optical network in order to protect the active equipment from the damage caused by the fuse effect.

  3. Relating surface roughness and magnetic domain structure to giant magneto-impedance of Co-rich melt-extracted microwires

    DOE PAGES

    Jiang, S. D.; Eggers, T.; Thiabgoh, O.; ...

    2017-04-11

    Understanding the relationship between the surface conditions and giant magneto-impedance (GMI) in Co-rich melt-extracted microwires is key to optimizing their magnetic responses for magnetic sensor applications. The surface magnetic domain structure (SMDS) parameters of ~45 μm diameter Co 69.25Fe 4.25Si 13B 13.5-xZr x (x = 0, 1, 2, 3) microwires, including the magnetic domain period (d) and surface roughness (Rq) as extracted from the magnetic force microscopy (MFM) images, have been correlated with GMI in the range 1–1000 MHz. It was found that substitution of B with 1 at. % Zr increased d of the base alloy from 729 tomore » 740 nm while retaining Rq from ~1 nm to ~3 nm. A tremendous impact on the GMI ratio was found, increasing the ratio from ~360% to ~490% at an operating frequency of 40 MHz. Further substitution with Zr decreased the high frequency GMI ratio, which can be understood by the significant increase in surface roughness evident by force microscopy. Lastly, this study demonstrates the application of the domain period and surface roughness found by force microscopy to the interpretation of the GMI in Co-rich microwires.« less

  4. Sunlight-Driven Hydrogen Formation by Membrane-Supported Photoelectrochemical Water Splitting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Nathan S.

    2014-03-26

    This report describes the significant advances in the development of the polymer-supported photoelectrochemical water-splitting system that was proposed under DOE grant number DE-FG02-05ER15754. We developed Si microwire-array photoelectrodes, demonstrated control over the material and light-absorption properties of the microwire-array photoelectrodes, developed inexpensive processes for synthesizing the arrays, and doped the arrays p-type for use as photocathodes. We also developed techniques for depositing metal-nanoparticle catalysts of the hydrogen-evolution reaction (HER) on the wire arrays, investigated the stability and catalytic performance of the nanoparticles, and demonstrated that Ni-Mo alloys are promising earth-abundant catalysts of the HER. We also developed methods that allowmore » reuse of the single-crystalline Si substrates used for microwire growth and methods of embedding the microwire photocathodes in plastic to enable large-scale processing and deployment of the technology. Furthermore we developed techniques for controlling the structure of WO3 films, and demonstrated that structural control can improve the quantum yield of photoanodes. Thus, by the conclusion of this project, we demonstrated significant advances in the development of all components of a sunlight-driven membrane-supported photoelectrochemical water-splitting system. This final report provides descriptions of some of the scientific accomplishments that were achieved under the support of this project and also provides references to the peer-reviewed publications that resulted from this effort.« less

  5. Exercise induces cortical plasticity after neonatal spinal cord injury in the rat

    PubMed Central

    Kao, T; Shumsky, JS; Murray, M; Moxon, KA

    2009-01-01

    Exercise-induced cortical plasticity is associated with improved functional outcome after brain or nerve injury. Exercise also improves functional outcomes after spinal cord injury, but its effects on cortical plasticity are not known. The goal of this investigation was to study the effect of moderate exercise (treadmill locomotion, 3 min/day, 5days/week) on the somatotopic organization of forelimb and hindlimb somatosensory cortex (SI) after neonatal thoracic transection. We used adult rats spinalized as neonates because some of these animals develop weight-supported stepping and, therefore, the relationship between cortical plasticity and stepping could also be examined. Acute, single-neuron mapping was used to determine the percentage of cortical cells responding to cutaneous forelimb stimulation in normal, spinalized, and exercised spinalized rats. Multiple single neuron recording from arrays of chronically implanted microwires examined the magnitude of response of these cells in normal and exercised spinalized rats. Our results show that exercise not only increased the percentage of responding cells in the hindlimb SI, but also increased the magnitude of the response of these cells. This increase in response magnitude was correlated with behavioral outcome measures. In the forelimb SI, neonatal transection reduced the percentage of responding cells to forelimb stimulation but exercise reversed this loss. This restoration in the percentage of responding cells after exercise was accompanied by an increase in their response magnitude. Therefore, the increase in responsiveness of hindlimb SI to forelimb stimulation after neonatal transection and exercise may be due, in part, to the effect of exercise on the forelimb SI. PMID:19515923

  6. Highly Sensitive and Long Term Stable Electrochemical Microelectrodes for Implantable Glucose Monitoring Devices

    NASA Astrophysics Data System (ADS)

    Qiang, Liangliang

    A miniature wireless implantable electrochemical glucose system for continuous glucose monitoring with good selectivity, sensitivity, linearity and long term stability was developed. First, highly sensitive, long-term stable and reusable planar H2O2 microelectrodes have been fabricated by microlithography. These electrodes composed of a 300 nm Pt black layer situated on a 5 um thick Au layer, provide effective protection to the underlying chromium adhesion layer. Using repeated cyclic voltammetric sweeps in flowing buffer solution, highly sensitive Pt black working electrodes were realized with five-decade linear dynamic range and low detection limit (10 nM) for H2O2 at low oxidation potentials. Second, a highly sensitive, low cost and flexible microwire biosensor was described using 25-mum thick gold wire as working electrode together with 125-mum thick Pt/Ir and Ag wires as counter and reference electrode, embedded within a PDMS-filled polyethylene tube. Surface area and activity of sensor was enhanced by converting gold electrode to nanoporous configuration followed by electrodeposition of platinum black. Glucose oxidase based biosensors by electrodeposition of poly(o-phenylenediamine) and glucose oxidase on the working electrode, displayed a higher glucose sensitivity (1.2 mA mM-1 cm-2) than highest literature reported. In addition it exhibits wide detection range (up to 20 mM) and selectivity (>95%). Third, novel miniaturized and flexible microelectrode arrays with 8 of 25 mum electrodes displayed the much needed 3D diffusion profiles similar to a single 25 mum microelectrode, but with one order increase in current levels. These microelectrode arrays displayed a H2O2 sensitivity of 13 mA mM-1 cm-2, a wide dynamic range of 100 nM to 10 mM, limit of detection of 10 nM. These microwire based edge plane microsensors incorporated flexibility, miniaturization and low operation potential are an promising approach for continuous in vivo metabolic monitoring. Fourth, homemade miniature wireless potentisotat was fabricated based on low power consumption integrated circuits and surface mount parts. The miniature wireless potentisotat with up to two week life-time for continuous glucose sensing has a size less than 9x22x10 mm and weight ˜3.4 grams. Primary in vivo experiment showed homemade system has the exactly same respond and trend as commercial glucose meter.

  7. Acute in vivo testing of a conformal polymer microelectrode array for multi-region hippocampal recordings

    NASA Astrophysics Data System (ADS)

    Xu, Huijing; Weltman Hirschberg, Ahuva; Scholten, Kee; Berger, Theodore William; Song, Dong; Meng, Ellis

    2018-02-01

    Objective. The success of a cortical prosthetic device relies upon its ability to attain resolvable spikes from many neurons in particular neural networks over long periods of time. Traditionally, lifetimes of neural recordings are greatly limited by the body’s immune response against the foreign implant which causes neuronal death and glial scarring. This immune reaction is posited to be exacerbated by micromotion between the implant, which is often rigid, and the surrounding, soft brain tissue, and attenuates the quality of recordings over time. Approach. In an attempt to minimize the foreign body response to a penetrating neural array that records from multiple brain regions, Parylene C, a flexible, biocompatible polymer was used as the substrate material for a functional, proof-of-concept neural array with a reduced elastic modulus. This probe array was designed and fabricated to have 64 electrodes positioned to match the anatomy of the rat hippocampus and allow for simultaneous recordings between two cell-body layers of interest. A dissolvable brace was used for deep-brain penetration of the flexible array. Main results. Arrays were electrochemically characterized at the benchtop, and a novel insertion technique that restricts acute insertion injury enabled accurate target placement of four, bare, flexible arrays to greater than 4 mm deep into the rat brain. Arrays were tested acutely and in vivo recordings taken intra-operatively reveal spikes in both targeted regions of the hippocampus with spike amplitudes and noise levels similar to those recorded with microwires. Histological staining of a sham array implanted for one month reveals limited astrocytic scarring and neuronal death around the implant. Significance. This work represents one of the first examples of a penetrating polymer probe array that records from individual neurons in structures that lie deep within the brain.

  8. Totally Implantable Wireless Ultrasonic Doppler Blood Flowmeters: Toward Accurate Miniaturized Chronic Monitors.

    PubMed

    Rothfuss, Michael A; Unadkat, Jignesh V; Gimbel, Michael L; Mickle, Marlin H; Sejdić, Ervin

    2017-03-01

    Totally implantable wireless ultrasonic blood flowmeters provide direct-access chronic vessel monitoring in hard-to-reach places without using wired bedside monitors or imaging equipment. Although wireless implantable Doppler devices are accurate for most applications, device size and implant lifetime remain vastly underdeveloped. We review past and current approaches to miniaturization and implant lifetime extension for wireless implantable Doppler devices and propose approaches to reduce device size and maximize implant lifetime for the next generation of devices. Additionally, we review current and past approaches to accurate blood flow measurements. This review points toward relying on increased levels of monolithic customization and integration to reduce size. Meanwhile, recommendations to maximize implant lifetime should include alternative sources of power, such as transcutaneous wireless power, that stand to extend lifetime indefinitely. Coupling together the results will pave the way for ultra-miniaturized totally implantable wireless blood flow monitors for truly chronic implantation. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Continuous Force Decoding from Local Field Potentials of the Primary Motor Cortex in Freely Moving Rats.

    PubMed

    Khorasani, Abed; Heydari Beni, Nargess; Shalchyan, Vahid; Daliri, Mohammad Reza

    2016-10-21

    Local field potential (LFP) signals recorded by intracortical microelectrodes implanted in primary motor cortex can be used as a high informative input for decoding of motor functions. Recent studies show that different kinematic parameters such as position and velocity can be inferred from multiple LFP signals as precisely as spiking activities, however, continuous decoding of the force magnitude from the LFP signals in freely moving animals has remained an open problem. Here, we trained three rats to press a force sensor for getting a drop of water as a reward. A 16-channel micro-wire array was implanted in the primary motor cortex of each trained rat, and obtained LFP signals were used for decoding of the continuous values recorded by the force sensor. Average coefficient of correlation and the coefficient of determination between decoded and actual force signals were r = 0.66 and R 2  = 0.42, respectively. We found that LFP signal on gamma frequency bands (30-120 Hz) had the most contribution in the trained decoding model. This study suggests the feasibility of using low number of LFP channels for the continuous force decoding in freely moving animals resembling BMI systems in real life applications.

  10. The Relation Between Child Versus Parent Report of Chronic Fatigue and Language/Literacy Skills in School-Age Children with Cochlear Implants.

    PubMed

    Werfel, Krystal L; Hendricks, Alison Eisel

    2016-01-01

    Preliminary evidence suggests that children with hearing loss experience elevated levels of chronic fatigue compared with children with normal hearing. Chronic fatigue is associated with decreased academic performance in many clinical populations. Children with cochlear implants as a group exhibit deficits in language and literacy skills; however, the relation between chronic fatigue and language and literacy skills for children with cochlear implants is unclear. The purpose of this study was to explore subjective ratings of chronic fatigue by children with cochlear implants and their parents, as well as the relation between chronic fatigue and language and literacy skills in this population. Nineteen children with cochlear implants in grades 3 to 6 and one of their parents separately completed a subjective chronic fatigue scale, on which they rated how much the child experienced physical, sleep/rest, and cognitive fatigue over the past month. In addition, children completed an assessment battery that included measures of speech perception, oral language, word reading, and spelling. Children and parents reported different levels of chronic child physical and sleep/rest fatigue. In both cases, parents reported significantly less fatigue than did children. Children and parents did not report different levels of chronic child cognitive fatigue. Child report of physical fatigue was related to speech perception, language, reading, and spelling. Child report of sleep/rest and cognitive fatigue was related to speech perception and language but not to reading or spelling. Parent report of child fatigue was not related to children's language and literacy skills. Taken as a whole, results suggested that parents under-estimate the fatigue experienced by children with cochlear implants. Child report of physical fatigue was robustly related to language and literacy skills. Children with cochlear implants are likely more accurate at reporting physical fatigue than cognitive fatigue. Clinical practice should take fatigue into account when developing treatment plans for children with cochlear implants, and research should continue to develop a comprehensive model of fatigue in children with cochlear implants.

  11. Nanoscale content-addressable memory

    NASA Technical Reports Server (NTRS)

    Davis, Bryan (Inventor); Principe, Jose C. (Inventor); Fortes, Jose (Inventor)

    2009-01-01

    A combined content addressable memory device and memory interface is provided. The combined device and interface includes one or more one molecular wire crossbar memories having spaced-apart key nanowires, spaced-apart value nanowires adjacent to the key nanowires, and configurable switches between the key nanowires and the value nanowires. The combination further includes a key microwire-nanowire grid (key MNG) electrically connected to the spaced-apart key nanowires, and a value microwire-nanowire grid (value MNG) electrically connected to the spaced-apart value nanowires. A key or value MNGs selects multiple nanowires for a given key or value.

  12. Omni-directional selective shielding material based on amorphous glass coated microwires.

    PubMed

    Ababei, G; Chiriac, H; David, V; Dafinescu, V; Nica, I

    2012-01-01

    The shielding effectiveness of the omni-directional selective shielding material based on CoFe-glass coated amorphous wires in 0.8 GHz-3 GHz microwave frequency range is investigated. The measurements were done in a controlled medium using a TEM cell and in the free space using horn antennas, respectively. Experimental results indicate that the composite shielding material can be developed with desired shielding effectiveness and selective absorption of the microwave frequency range by controlling the number of the layers and the length of microwires.

  13. Magnetoresistance oscillations in topological insulator microwires contacted with normal and superconducting leads

    NASA Astrophysics Data System (ADS)

    Konopko, Leonid; Nikolaeva, Albina; Huber, Tito E.; Rogacki, Krzysztof

    2018-05-01

    Recent efforts to detect and manipulate Majorana fermions in solid state devices have employed topological insulator (TI) nanowires proximity coupled to superconducting (SC) leads. This combination holds some promises for the fundamental physics and applications. We studied the transverse magnetoresistance (MR) of polycrystal Bi2Te2Se and single-crystal Bi0.83Sb0.17 TI microwires contacted with superconducting In2Bi leads. Bi2Te2Se has a simple band structure with a single Dirac cone on the surface and a large non-trivial bulk gap of 300 meV. The semiconducting alloy Bi0.83Sb0.17 is a strong topological insulator due to the inversion symmetry of bulk crystalline Bi and Sb. To study the TI/SC interface, we prepared Bi2Te2Se and Bi0.83Sb0.17 glass-coated microwire samples using superconducting alloy In2Bi (Tc = 5.6 K) to provide a contact of one side of the microwires with copper leads and gallium to provide a contact of the other side of microwires with copper leads. The MR oscillations equidistant in a transverse magnetic field (up to 1 T) at the TI/SC interface were observed at various temperatures (4.2 K-1.5 K) in both the Bi2Te2Se and Bi0.83Sb0.17 samples. In the Bi2Te3 sample with a diameter of d = 17 μm, this oscillations exist with a period of ΔB = 18 mT; in the Bi0.83Sb0.17 sample with d = 1.7 μm MR oscillations are characterized by a period of ΔB = 46 mT. The observed oscillations cannot be referred to the Shubnikov de Haas oscillations because they are not periodic in an inverse magnetic field and their amplitude decreases with increasing magnetic field. Most probably, transverse MR oscillations arise owing to the appearance of highly conducting edge states on the planar boundary of SC/TI.

  14. Renewable Solid Electrodes in Microfluidics: Recovering the Electrochemical Activity without Treating the Surface.

    PubMed

    Teixeira, Carlos A; Giordano, Gabriela F; Beltrame, Maisa B; Vieira, Luis C S; Gobbi, Angelo L; Lima, Renato S

    2016-11-15

    The contamination, passivation, or fouling of the detection electrodes is a serious problem undermining the analytical performance of electroanalytical devices. The methods to regenerate the electrochemical activity of the solid electrodes involve mechanical, physical, or chemical surface treatments that usually add operational time, complexity, chemicals, and further instrumental requirements to the analysis. In this paper, we describe for the first time a reproducible method for renewing solid electrodes whenever their morphology or composition are nonspecifically changed without any surface treatment. These renewable electrodes are the closest analogue to the mercury drop electrodes. Our approach was applied in microfluidics, where the downsides related to nonspecific modifications of the electrode are more critical. The renewal consisted in manually sliding metal-coated microwires across a channel with the sample. For this purpose, the chip was composed of a single piece of polydimethylsiloxane (PDMS) with three parallel channels interconnected to one perpendicular and top channel. The microwires were inserted in each one of the parallel channels acting as working, counter, and pseudoreference electrodes for voltammetry. This assembly allowed the renewal of all the three electrodes by simply pulling the microwires. The absence of any interfaces in the chips and the elastomeric nature of the PDMS allowed us to pull the microwires without the occurrence of leakages for the electrode channels even at harsh flow rates of up to 40.0 mL min -1 . We expect this paper can assist the researchers to develop new microfluidic platforms that eliminate any steps of electrode cleaning, representing a powerful alternative for precise and robust analyses to real samples.

  15. LC and ferromagnetic resonance in soft/hard magnetic microwires

    NASA Astrophysics Data System (ADS)

    Tian, Bin; Vazquez, Manuel

    2015-12-01

    The magnetic behavior of soft/hard biphase microwires is introduced here. The microwires consist of a Co59.1Fe14.8Si10.2B15.9 soft magnetic nucleus and a Co90Ni10 hard outer shell separated by an intermediate insulating Pyrex glass microtube. By comparing the resistance spectrums of welding the ends of metallic core (CC) or welding the metallic core and outer shell (CS) to the connector, it is found that one of the two peaks in the resistance spectrum is because the LC resonance depends on the inductor and capacitors in which one is the capacitor between the metallic core and outer shell, and the other is between the outer shell and connector. Correspondingly, another peak is for the ferromagnetic resonance of metallic core. After changing the capacitance of the capacitors, the frequency of LC resonance moves to high frequency band, and furthermore, the peak of LC resonance in the resistance spectrum disappeared. These magnetostatically coupled biphase systems are thought to be of large potential interest as sensing elements in sensor devices.

  16. Fabrication of hierarchical CoP nanosheet@microwire arrays via space-confined phosphidation toward high-efficiency water oxidation electrocatalysis under alkaline conditions.

    PubMed

    Ji, Xuqiang; Zhang, Rong; Shi, Xifeng; Asiri, Abdullah M; Zheng, Baozhan; Sun, Xuping

    2018-05-03

    In spite of recent advances in the synthesis of transition metal phosphide nanostructures, the simple fabrication of hierarchical arrays with more accessible active sites still remains a great challenge. In this Communication, we report a space-confined phosphidation strategy toward developing hierarchical CoP nanosheet@microwire arrays on nickel foam (CoP NS@MW/NF) using a Co(H2PO4)2·2H3PO4 microwire array as the precursor. The thermally stable nature of the anion in the precursor is key to hierarchical nanostructure formation. When used as a 3D electrode for water oxidation electrocatalysis, such CoP NS@MW/NF needs an overpotential as low as 296 mV to drive a geometrical catalytic current density of 100 mA cm-2 in 1.0 M KOH, outperforming all reported Co phosphide catalysts in alkaline media. This catalyst also shows superior long-term electrochemical durability, maintaining its activity for at least 65 h. This study offers us a general method for facile preparation of hierarchical arrays for applications.

  17. An embedded stress sensor for concrete SHM based on amorphous ferromagnetic microwires.

    PubMed

    Olivera, Jesús; González, Margarita; Fuente, José Vicente; Varga, Rastislav; Zhukov, Arkady; Anaya, José Javier

    2014-10-24

    A new smart concrete aggregate design as a candidate for applications in structural health monitoring (SHM) of critical elements in civil infrastructure is proposed. The cement-based stress/strain sensor was developed by utilizing the stress/strain sensing properties of a magnetic microwire embedded in cement-based composite (MMCC). This is a contact-less type sensor that measures variations of magnetic properties resulting from stress variations. Sensors made of these materials can be designed to satisfy the specific demand for an economic way to monitor concrete infrastructure health. For this purpose, we embedded a thin magnetic microwire in the core of a cement-based cylinder, which was inserted into the concrete specimen under study as an extra aggregate. The experimental results show that the embedded MMCC sensor is capable of measuring internal compressive stress around the range of 1-30 MPa. Two stress sensing properties of the embedded sensor under uniaxial compression were studied: the peak amplitude and peak position of magnetic switching field. The sensitivity values for the amplitude and position within the measured range were 5 mV/MPa and 2.5 µs/MPa, respectively.

  18. pH-triggered conduction of amine-functionalized single ZnO wire integrated on a customized nanogap electronic platform

    PubMed Central

    2014-01-01

    The electrical conductance response of single ZnO microwire functionalized with amine-groups was tested upon an acid pH variation of a solution environment after integration on a customized gold electrode array chip. ZnO microwires were easily synthesized by hydrothermal route and chemically functionalized with aminopropyl groups. Single wires were deposited from the solution and then oriented through dielectrophoresis across eight nanogap gold electrodes on a platform single chip. Therefore, eight functionalized ZnO microwire-gold junctions were formed at the same time, and being integrated on an ad hoc electronic platform, they were ready for testing without any further treatment. Experimental and simulation studies confirmed the high pH-responsive behavior of the amine-modified ZnO-gold junctions, obtaining in a simple and reproducible way a ready-to-use device for pH detection in the acidic range. We also compared this performance to bare ZnO wires on the same electronic platform, showing the superiority in pH response of the amine-functionalized material. PMID:24484615

  19. Enhancement of conductance of GaAs sub-microwires under external stimuli

    NASA Astrophysics Data System (ADS)

    Qu, Xianlin; Deng, Qingsong; Zheng, Kun

    2018-03-01

    Semiconductors with one dimension on the micro-nanometer scale have many unique physical properties that are remarkably different from those of their bulk counterparts. Moreover, changes in the external field will further modulate the properties of the semiconductor micro-nanomaterials. In this study, we used focused ion beam technology to prepare freestanding ⟨111⟩-oriented GaAs sub-microwires from a GaAs substrate. The effects of laser irradiation and bending or buckling deformation induced by compression on the electrical transport properties of an individual GaAs sub-microwire were studied. The experimental results indicate that both laser irradiation and bending deformation can enhance their electrical transport properties, the laser irradiation resulted in a conductance enhancement of ˜30% compared to the result with no irradiation, and in addition, bending deformation changed the conductance by as much as ˜180% when the average strain was approximately 1%. The corresponding mechanisms are also discussed. This study provides beneficial insight into the fabrication of electronic and optoelectronic devices based on GaAs micro/nano-wires.

  20. Dynamic changes of rodent somatosensory barrel cortex are correlated with learning a novel conditioned stimulus.

    PubMed

    Long, John D; Carmena, Jose M

    2013-05-01

    The rodent somatosensory barrel cortex (S1bf) has proved a valuable model for studying neural plasticity in vivo. It has been observed that sensory deprivation or conditioning reorganizes sensory-driven activity within S1bf. These observations suggest a role for S1bf in somatosensory learning. This study evaluated the hypothesis that the response properties of extracellularly recorded neurons in S1bf would change as subjects learned to respond to stimulation of S1bf. Intracortical microstimulation (ICMS) of S1bf was used as a means for bypassing feedforward drive from the sensory periphery, midbrain, and thalamus while exciting local cortical networks. To separate the learning of this conditioned stimulus-conditioned response (CS-CR) from other elements of the task, we employed a cross-modal transfer schedule. Long-Evans rats were initially trained to respond to an auditory stimulus. All subjects were then implanted in both S1bfs with chronic microwire arrays for recording neural activity and delivering ICMS. Next, this association was transferred to ICMS of one hemisphere's S1bf. S1bf responded to ICMS with a brief increase in firing rate followed by a longer reduction in activity. We observed that the duration of reduced activity elicited by ICMS increased as the subjects began to respond correctly more often than expected by chance, and the magnitude of the initial positive response increased as they consolidated this CS-CR. Subsequent ICMS of the opposite S1bf revealed that this CS-CR did not generalize across hemispheres. These results suggest that a mechanism involving a single hemisphere's S1bf tunes cortical responses in concert with changes in rodent behavior during somatosensory learning.

  1. Decoding bipedal locomotion from the rat sensorimotor cortex.

    PubMed

    Rigosa, J; Panarese, A; Dominici, N; Friedli, L; van den Brand, R; Carpaneto, J; DiGiovanna, J; Courtine, G; Micera, S

    2015-10-01

    Decoding forelimb movements from the firing activity of cortical neurons has been interfaced with robotic and prosthetic systems to replace lost upper limb functions in humans. Despite the potential of this approach to improve locomotion and facilitate gait rehabilitation, decoding lower limb movement from the motor cortex has received comparatively little attention. Here, we performed experiments to identify the type and amount of information that can be decoded from neuronal ensemble activity in the hindlimb area of the rat motor cortex during bipedal locomotor tasks. Rats were trained to stand, step on a treadmill, walk overground and climb staircases in a bipedal posture. To impose this gait, the rats were secured in a robotic interface that provided support against the direction of gravity and in the mediolateral direction, but behaved transparently in the forward direction. After completion of training, rats were chronically implanted with a micro-wire array spanning the left hindlimb motor cortex to record single and multi-unit activity, and bipolar electrodes into 10 muscles of the right hindlimb to monitor electromyographic signals. Whole-body kinematics, muscle activity, and neural signals were simultaneously recorded during execution of the trained tasks over multiple days of testing. Hindlimb kinematics, muscle activity, gait phases, and locomotor tasks were decoded using offline classification algorithms. We found that the stance and swing phases of gait and the locomotor tasks were detected with accuracies as robust as 90% in all rats. Decoded hindlimb kinematics and muscle activity exhibited a larger variability across rats and tasks. Our study shows that the rodent motor cortex contains useful information for lower limb neuroprosthetic development. However, brain-machine interfaces estimating gait phases or locomotor behaviors, instead of continuous variables such as limb joint positions or speeds, are likely to provide more robust control strategies for the design of such neuroprostheses.

  2. Chronically implanted pressure sensors: challenges and state of the field.

    PubMed

    Yu, Lawrence; Kim, Brian J; Meng, Ellis

    2014-10-31

    Several conditions and diseases are linked to the elevation or depression of internal pressures from a healthy, normal range, motivating the need for chronic implantable pressure sensors. A simple implantable pressure transduction system consists of a pressure-sensing element with a method to transmit the data to an external unit. The biological environment presents a host of engineering issues that must be considered for long term monitoring. Therefore, the design of such systems must carefully consider interactions between the implanted system and the body, including biocompatibility, surgical placement, and patient comfort. Here we review research developments on implantable sensors for chronic pressure monitoring within the body, focusing on general design requirements for implantable pressure sensors as well as specifications for different medical applications. We also discuss recent efforts to address biocompatibility, efficient telemetry, and drift management, and explore emerging trends.

  3. Recent refinements to cranial implants for rhesus macaques (Macaca mulatta)

    PubMed Central

    Johnston, Jessica M.; Cohen, Yale E.; Shirley, Harry; Tsunada, Joji; Bennur, Sharath; Christison-Lagay, Kate; Veeder, Christin L.

    2017-01-01

    The advent of cranial implants revolutionized primate neurophysiological research because they allow researchers to stably record neural activity from monkeys during active behavior. Cranial implants have improved over the years since their introduction, but chronic implants still increase the risk for medical complications including bacterial contamination and resultant infection, chronic inflammation, bone and tissue loss and complications related to the use of dental acrylic. These complications can lead to implant failure and early termination of study protocols. In an effort to reduce complications, we describe several refinements that have helped us improve cranial implants and the wellbeing of implanted primates. PMID:27096188

  4. Control of reversible magnetization switching by pulsed circular magnetic field in glass-coated amorphous microwires

    NASA Astrophysics Data System (ADS)

    Chizhik, Alexander; Zhukov, Arkady; Gonzalez, Julian; Stupakiewicz, Andrzej

    2018-02-01

    Magnetization reversal in magnetic microwires was studied in the presence of external mechanical stress and helical magnetic fields using the magneto-optical Kerr effect. It was found that a combination of tuned magnetic anisotropy and a direct current or pulsed circular magnetic field activated different types of magnetization reversal scenarios. The application of the pulsed magnetic field of 10 ns time duration induced a transient controlling action to switch the magnetic states without activating a domain wall motion. This created a promising method for tuning the giant magneto-impedance effect.

  5. A Rodent Model of Dynamic Facial Reanimation Using Functional Electrical Stimulation

    PubMed Central

    Attiah, Mark A.; de Vries, Julius; Richardson, Andrew G.; Lucas, Timothy H.

    2017-01-01

    Facial paralysis can be a devastating condition, causing disfiguring facial droop, slurred speech, eye dryness, scarring and blindness. This study investigated the utility of closed-loop functional electric stimulation (FES) for reanimating paralyzed facial muscles in a quantitative rodent model. The right buccal and marginal mandibular branches of the rat facial nerve were transected for selective, unilateral paralysis of whisker muscles. Microwire electrodes were implanted bilaterally into the facial musculature for FES and electromyographic (EMG) recording. With the rats awake and head-fixed, whisker trajectories were tracked bilaterally with optical micrometers. First, the relationship between EMG and volitional whisker movement was quantified on the intact side of the face. Second, the effect of FES on whisker trajectories was quantified on the paralyzed side. Third, closed-loop experiments were performed in which the EMG signal on the intact side triggered FES on the paralyzed side to restore symmetric whisking. The results demonstrate a novel in vivo platform for developing control strategies for neuromuscular facial prostheses. PMID:28424583

  6. Chronically Implanted Pressure Sensors: Challenges and State of the Field

    PubMed Central

    Yu, Lawrence; Kim, Brian J.; Meng, Ellis

    2014-01-01

    Several conditions and diseases are linked to the elevation or depression of internal pressures from a healthy, normal range, motivating the need for chronic implantable pressure sensors. A simple implantable pressure transduction system consists of a pressure-sensing element with a method to transmit the data to an external unit. The biological environment presents a host of engineering issues that must be considered for long term monitoring. Therefore, the design of such systems must carefully consider interactions between the implanted system and the body, including biocompatibility, surgical placement, and patient comfort. Here we review research developments on implantable sensors for chronic pressure monitoring within the body, focusing on general design requirements for implantable pressure sensors as well as specifications for different medical applications. We also discuss recent efforts to address biocompatibility, efficient telemetry, and drift management, and explore emerging trends. PMID:25365461

  7. Electrically excited hot-electron dominated fluorescent emitters using individual Ga-doped ZnO microwires via metal quasiparticle film decoration.

    PubMed

    Liu, Yang; Jiang, Mingming; Zhang, Zhenzhong; Li, Binghui; Zhao, Haifeng; Shan, Chongxin; Shen, Dezhen

    2018-03-28

    The generation of hot electrons from metal nanostructures through plasmon decay provided a direct interfacial charge transfer mechanism, which no longer suffers from the barrier height restrictions observed for metal/semiconductor interfaces. Metal plasmon-mediated energy conversion with higher efficiency has been proposed as a promising alternative to construct novel optoelectronic devices, such as photodetectors, photovoltaic and photocatalytic devices, etc. However, the realization of the electrically-driven generation of hot electrons, and the application in light-emitting devices remain big challenges. Here, hybrid architectures comprising individual Ga-doped ZnO (ZnO:Ga) microwires via metal quasiparticle film decoration were fabricated. The hottest spots could be formed towards the center of the wires, and the quasiparticle films were converted into physically isolated nanoparticles by applying a bias onto the wires. Thus, the hot electrons became spatially localized towards the hottest regions, leading to a release of energy in the form of emitting photons. By adjusting the sputtering times and appropriate alloys, such as Au and Ag, wavelength-tunable emissions could be achieved. To exploit the EL emission characteristics, metal plasmons could be used as active elements to mediate the generation of hot electrons from metal nanostructures, which are located in the light-emitting regions, followed by injection into ZnO:Ga microwire-channels; thus, the production of plasmon decay-induced hot-electrons could function as an efficient approach to dominate emission wavelengths. Therefore, by introducing metal nanostructure decoration, individual ZnO:Ga microwires can be used to construct wavelength-tunable fluorescent emitters. The hybrid architectures of metal-ZnO micro/nanostructures offer a fantastic candidate to broaden the potential applications of semiconducting optoelectronic devices, such as photovoltaic devices, photodetectors, optoelectronic sensors, etc.

  8. Real-time control of walking using recordings from dorsal root ganglia.

    PubMed

    Holinski, B J; Everaert, D G; Mushahwar, V K; Stein, R B

    2013-10-01

    The goal of this study was to decode sensory information from the dorsal root ganglia (DRG) in real time, and to use this information to adapt the control of unilateral stepping with a state-based control algorithm consisting of both feed-forward and feedback components. In five anesthetized cats, hind limb stepping on a walkway or treadmill was produced by patterned electrical stimulation of the spinal cord through implanted microwire arrays, while neuronal activity was recorded from the DRG. Different parameters, including distance and tilt of the vector between hip and limb endpoint, integrated gyroscope and ground reaction force were modelled from recorded neural firing rates. These models were then used for closed-loop feedback. Overall, firing-rate-based predictions of kinematic sensors (limb endpoint, integrated gyroscope) were the most accurate with variance accounted for >60% on average. Force prediction had the lowest prediction accuracy (48 ± 13%) but produced the greatest percentage of successful rule activations (96.3%) for stepping under closed-loop feedback control. The prediction of all sensor modalities degraded over time, with the exception of tilt. Sensory feedback from moving limbs would be a desirable component of any neuroprosthetic device designed to restore walking in people after a spinal cord injury. This study provides a proof-of-principle that real-time feedback from the DRG is possible and could form part of a fully implantable neuroprosthetic device with further development.

  9. Living fungal hyphae-templated porous gold microwires using nanoparticles as building blocks

    NASA Astrophysics Data System (ADS)

    Rehman, Asma; Majeed, Muhammad Irfan; Ihsan, Ayesha; Hussain, Syed Zajif; Saif-ur-Rehman; Ghauri, Muhammad Afzal; Khalid, Zafar M.; Hussain, Irshad

    2011-12-01

    A simple and environmentally benign green method is reported to decorate growing fungal hyphae with high loading of gold nanoparticles, which were initially produced using aqueous tea extract as a sole reducing/stabilizing agent. Inoculation of fungal spores in aqueous suspension of nanoparticles led to the growth of intensely red-coloured fungal hyphae due to the accumulation of gold nanoparticles. Heat treatment of these hybrid materials led to the formation of porous gold microwires. This report is thus an interesting example of using green and sustainable approach to produce nanostructured materials which have potential applications in catalysis, sensing and electronics.

  10. GaN microwires as optical microcavities: whispering gallery modes Vs Fabry-Perot modes.

    PubMed

    Coulon, Pierre-Marie; Hugues, Maxime; Alloing, Blandine; Beraudo, Emmanuel; Leroux, Mathieu; Zuniga-Perez, Jesus

    2012-08-13

    GaN microwires grown by metalorganic vapour phase epitaxy and with radii typically on the order of 1-5 micrometers exhibit a number of resonances in their photoluminescence spectra. These resonances include whispering gallery modes and transverse Fabry-Perot modes. A detailed spectroscopic study by polarization-resolved microphotoluminescence, in combination with electron microscopy images, has enabled to differentiate both kinds of modes and determined their main spectral properties. Finally, the dispersion of the ordinary and extraordinary refractive indices of strain-free GaN in the visible-UV range has been obtained thanks to the numerical simulation of the observed modes.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, S. D.; Eggers, T.; Thiabgoh, O.

    Understanding the relationship between the surface conditions and giant magneto-impedance (GMI) in Co-rich melt-extracted microwires is key to optimizing their magnetic responses for magnetic sensor applications. The surface magnetic domain structure (SMDS) parameters of ~45 μm diameter Co 69.25Fe 4.25Si 13B 13.5-xZr x (x = 0, 1, 2, 3) microwires, including the magnetic domain period (d) and surface roughness (Rq) as extracted from the magnetic force microscopy (MFM) images, have been correlated with GMI in the range 1–1000 MHz. It was found that substitution of B with 1 at. % Zr increased d of the base alloy from 729 tomore » 740 nm while retaining Rq from ~1 nm to ~3 nm. A tremendous impact on the GMI ratio was found, increasing the ratio from ~360% to ~490% at an operating frequency of 40 MHz. Further substitution with Zr decreased the high frequency GMI ratio, which can be understood by the significant increase in surface roughness evident by force microscopy. Lastly, this study demonstrates the application of the domain period and surface roughness found by force microscopy to the interpretation of the GMI in Co-rich microwires.« less

  12. An Embedded Stress Sensor for Concrete SHM Based on Amorphous Ferromagnetic Microwires

    PubMed Central

    Olivera, Jesús; González, Margarita; Fuente, José Vicente; Varga, Rastislav; Zhukov, Arkady; Anaya, José Javier

    2014-01-01

    A new smart concrete aggregate design as a candidate for applications in structural health monitoring (SHM) of critical elements in civil infrastructure is proposed. The cement-based stress/strain sensor was developed by utilizing the stress/strain sensing properties of a magnetic microwire embedded in cement-based composite (MMCC). This is a contact-less type sensor that measures variations of magnetic properties resulting from stress variations. Sensors made of these materials can be designed to satisfy the specific demand for an economic way to monitor concrete infrastructure health. For this purpose, we embedded a thin magnetic microwire in the core of a cement-based cylinder, which was inserted into the concrete specimen under study as an extra aggregate. The experimental results show that the embedded MMCC sensor is capable of measuring internal compressive stress around the range of 1–30 MPa. Two stress sensing properties of the embedded sensor under uniaxial compression were studied: the peak amplitude and peak position of magnetic switching field. The sensitivity values for the amplitude and position within the measured range were 5 mV/MPa and 2.5 μs/MPa, respectively. PMID:25347582

  13. In vivo characterization of the electrophysiological and astrocytic responses to a silicon neuroprobe implanted in the mouse neocortex.

    PubMed

    Mols, Katrien; Musa, Silke; Nuttin, Bart; Lagae, Liesbet; Bonin, Vincent

    2017-11-15

    Silicon neuroprobes hold great potential for studies of large-scale neural activity and brain computer interfaces, but data on brain response in chronic implants is limited. Here we explored with in vivo cellular imaging the response to multisite silicon probes for neural recordings. We tested a chronic implant for mice consisting of a CMOS-compatible silicon probe rigidly implanted in the cortex under a cranial imaging window. Multiunit recordings of cortical neurons with the implant showed no degradation of electrophysiological signals weeks after implantation (mean spike and noise amplitudes of 186 ± 42 µV pp and 16 ± 3.2 µV rms , respectively, n = 5 mice). Two-photon imaging through the cranial window allowed longitudinal monitoring of fluorescently-labeled astrocytes from the second week post implantation for 8 weeks (n = 3 mice). The imaging showed a local increase in astrocyte-related fluorescence that remained stable from the second to the tenth week post implantation. These results demonstrate that, in a standard electrophysiology protocol in mice, rigidly implanted silicon probes can provide good short to medium term chronic recording performance with a limited astrocyte inflammatory response. The precise factors influencing the response to silicon probe implants remain to be elucidated.

  14. Teicoplanin-loaded borate bioactive glass implants for treating chronic bone infection in a rabbit tibia osteomyelitis model.

    PubMed

    Zhang, Xin; Jia, Weitao; Gu, Yifei; Xiao, Wei; Liu, Xin; Wang, Deping; Zhang, Changqing; Huang, Wenhai; Rahaman, Mohamed N; Day, Delbert E; Zhou, Nai

    2010-08-01

    The treatment of chronic osteomyelitis (bone infection) remains a clinical challenge. In this work, pellets composed of a chitosan-bonded mixture of borate bioactive glass particles (<50microm) and teicoplanin powder (antibiotic), were evaluated in vitro and in vivo for treating chronic osteomyelitis induced by methicillin-resistant Staphylococcus aureus (MRSA) in a rabbit model. When immersed in phosphate-buffered saline, the pellets showed sustained release of teicoplanin over 20-30 days, while the bioactive glass converted to hydroxyapatite (HA) within 7 days, eventually forming a porous HA structure. Implantation of the teicoplanin-loaded pellets in a rabbit tibia osteomyelitis model resulted in the detection of teicoplanin in the blood for about 9 days. The implants converted to a bone-like HA graft, and supported the ingrowth of new bone into the tibia defects within 12 weeks of implantation. Microbiological, histological and scanning electron microscopy techniques showed that the implants provided a cure for the bone infection. The results indicate that the teicoplanin-loaded borate bioactive glass implant, combining sustained drug release with the ability to support new bone ingrowth, could provide a method for treating chronic osteomyelitis. Copyright 2010 Elsevier Ltd. All rights reserved.

  15. Self-expandable CoreValve implantation without contrast media.

    PubMed

    Bruschi, Giuseppe; Colombo, Paola; De Marco, Federico; Barosi, Alberto; Mauri, Silvia; Klugmann, Silvio

    2016-09-01

    Transcatheter aortic valve implantation has been designed to treat high-risk surgical patients affected by severe aortic stenosis, many of whom are affected by chronic kidney disease. To perform transcatheter self-expandable valve implantation, multiple contrast injections are required to monitor the procedure, so these patients are at increased risk of acute kidney injury. We described self-expandable transcatheter aortic valve implantation without contrast media in an 80-year-old man affected by severe aortic stenosis and endstage chronic kidney disease. © The Author(s) 2015.

  16. Chronic behavior evaluation of a micro-machined neural implant with optimized design based on an experimentally derived model.

    PubMed

    Andrei, Alexandru; Welkenhuysen, Marleen; Ameye, Lieveke; Nuttin, Bart; Eberle, Wolfgang

    2011-01-01

    Understanding the mechanical interactions between implants and the surrounding tissue is known to have an important role for improving the bio-compatibility of such devices. Using a recently developed model, a particular micro-machined neural implant design aiming the reduction of insertion forces dependence on the insertion speed was optimized. Implantations with 10 and 100 μm/s insertion speeds showed excellent agreement with the predicted behavior. Lesion size, gliosis (GFAP), inflammation (ED1) and neuronal cells density (NeuN) was evaluated after 6 week of chronic implantation showing no insertion speed dependence.

  17. Cortical activation following chronic passive implantation of a wide-field suprachoroidal retinal prosthesis

    NASA Astrophysics Data System (ADS)

    Villalobos, Joel; Fallon, James B.; Nayagam, David A. X.; Shivdasani, Mohit N.; Luu, Chi D.; Allen, Penelope J.; Shepherd, Robert K.; Williams, Chris E.

    2014-08-01

    Objective. The research goal is to develop a wide-field retinal stimulating array for prosthetic vision. This study aimed at evaluating the efficacy of a suprachoroidal electrode array in evoking visual cortex activity after long term implantation. Approach. A planar silicone based electrode array (8 mm × 19 mm) was implanted into the suprachoroidal space in cats (ntotal = 10). It consisted of 20 platinum stimulating electrodes (600 μm diameter) and a trans-scleral cable terminated in a subcutaneous connector. Three months after implantation (nchronic = 6), or immediately after implantation (nacute = 4), an electrophysiological study was performed. Electrode total impedance was measured from voltage transients using 500 μs, 1 mA pulses. Electrically evoked potentials (EEPs) and multi-unit activity were recorded from the visual cortex in response to monopolar retinal stimulation. Dynamic range and cortical activation spread were calculated from the multi-unit recordings. Main results. The mean electrode total impedance in vivo following 3 months was 12.5 ± 0.3 kΩ. EEPs were recorded for 98% of the electrodes. The median evoked potential threshold was 150 nC (charge density 53 μC cm-2). The lowest stimulation thresholds were found proximal to the area centralis. Mean thresholds from multiunit activity were lower for chronic (181 ± 14 nC) compared to acute (322 ± 20 nC) electrodes (P < 0.001), but there was no difference in dynamic range or cortical activation spread. Significance. Suprachoroidal stimulation threshold was lower in chronic than acute implantation and was within safe charge limits for platinum. Electrode-tissue impedance following chronic implantation was higher, indicating the need for sufficient compliance voltage (e.g. 12.8 V for mean impedance, threshold and dynamic range). The wide-field suprachoroidal array reliably activated the retina after chronic implantation.

  18. Circadian Rhythm Control: Neurophysiological Investigations

    NASA Technical Reports Server (NTRS)

    Glotzbach, S. F.

    1985-01-01

    The suprachiasmatic nucleus (SCN) was implicated as a primary component in central nervous system mechanisms governing circadian rhythms. Disruption of the normal synchronization of temperature, activity, and other rhythms is detrimental to health. Sleep wake disorders, decreases in vigilance and performance, and certain affective disorders may result from or be exacerbated by such desynchronization. To study the basic neurophysiological mechanisms involved in entrainment of circadian systems by the environment, Parylene-coated, etched microwire electrode bundles were used to record extracellular action potentials from the small somata of the SCN and neighboring hypothalamic nuclei in unanesthetized, behaving animals. Male Wistar rats were anesthetized and chronically prepared with EEG ane EMG electrodes in addition to a moveable microdrive assembly. The majority of cells had firing rates 10 Hz and distinct populations of cells which had either the highest firing rate or lowest firing rate during sleep were seen.

  19. Functional and Histological Effects of Chronic Neural Electrode Implantation.

    PubMed

    Sahyouni, Ronald; Chang, David T; Moshtaghi, Omid; Mahmoodi, Amin; Djalilian, Hamid R; Lin, Harrison W

    2017-04-01

    Permanent injury to the cranial nerves can often result in a substantial reduction in quality of life. Novel and innovative interventions can help restore form and function in nerve paralysis, with bioelectric interfaces among the more promising of these approaches. The foreign body response is an important consideration for any bioelectric device as it influences the function and effectiveness of the implant. The purpose of this review is to describe tissue and functional effects of chronic neural implantation among the different categories of neural implants and highlight advances in peripheral and cranial nerve stimulation. Data Sources : PubMed, IEEE, and Web of Science literature search. Review Methods : A review of the current literature was conducted to examine functional and histologic effects of bioelectric interfaces for neural implants. Bioelectric devices can be characterized as intraneural, epineural, perineural, intranuclear, or cortical depending on their placement relative to nerves and neuronal cell bodies. Such devices include nerve-specific stimulators, neuroprosthetics, brainstem implants, and deep brain stimulators. Regardless of electrode location and interface type, acute and chronic histological, macroscopic and functional changes can occur as a result of both passive and active tissue responses to the bioelectric implant. A variety of chronically implantable electrodes have been developed to treat disorders of the peripheral and cranial nerves, to varying degrees of efficacy. Consideration and mitigation of detrimental effects at the neural interface with further optimization of functional nerve stimulation will facilitate the development of these technologies and translation to the clinic. 3.

  20. Local and Systemic Changes Associated with Long-term, Percutaneous, Static Implantation of Titanium Alloys in Rhesus Macaques (Macaca mulatta)

    PubMed Central

    Frydman, Galit H; Marini, Robert P; Bakthavatchalu, Vasudevan; Biddle, Kathleen E; Muthupalani, Sureshkumar; Vanderburg, Charles R; Lai, Barry; Bendapudi, Pavan K; Tompkins, Ronald G; Fox, James G

    2017-01-01

    Metal alloys are frequently used as implant materials in veterinary medicine. Recent studies suggest that many alloys induce both local and systemic inflammatory responses. In this study, 37 rhesus macaques with long-term skull-anchored percutaneous titanium alloy implants (duration, 0 to 14 y) were evaluated for changes in their hematology, coagulation, and serum chemistry profiles. Negative controls (n = 28) did not have implants. Macaques with implants had higher plasma D-dimer and lower antithrombin III concentrations than nonimplanted animals. In addition, animals with implants had higher globulin and lower albumin and calcium concentrations compared with nonimplanted macaques. Many of these changes were positively correlated with duration of implantation and the number of implants. Chronic bacterial infection of the skin was present around many of the implant sites and within deeper tissues. Representative histopathology around the implant site of 2 macaques revealed chronic suppurative to pyogranulomatous inflammation extending from the skin to the dura mater. X-ray fluorescence microscopy of tissue biopsies from the implant site of the same 2 animals revealed significantly higher levels of free metal ions in the tissue, including titanium and iron. The higher levels of free metal ions persisted in the tissues for as long as 6 mo after explantation. These results suggest that long-term skull-anchored percutaneous titanium alloy implants can be associated with localized inflammation, chronic infection, and leaching of metal ions into local tissues. PMID:28381317

  1. Mechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design

    PubMed Central

    Prodanov, Dimiter; Delbeke, Jean

    2016-01-01

    Neural prostheses have already a long history and yet the cochlear implant remains the only success story about a longterm sensory function restoration. On the other hand, neural implants for deep brain stimulation are gaining acceptance for variety of disorders including Parkinsons disease and obsessive-compulsive disorder. It is anticipated that the progress in the field has been hampered by a combination of technological and biological factors, such as the limited understanding of the longterm behavior of implants, unreliability of devices, biocompatibility of the implants among others. While the field's understanding of the cell biology of interactions at the biotic-abiotic interface has improved, relatively little attention has been paid on the mechanical factors (stress, strain), and hence on the geometry that can modulate it. This focused review summarizes the recent progress in the understanding of the mechanisms of mechanical interaction between the implants and the brain. The review gives an overview of the factors by which the implants interact acutely and chronically with the tissue: blood-brain barrier (BBB) breach, vascular damage, micromotions, diffusion etc. We propose some design constraints to be considered in future studies. Aspects of the chronic cell-implant interaction will be discussed in view of the chronic local inflammation and the ways of modulating it. PMID:26903786

  2. Immediate Implants Placed in Fresh Sockets Associated with Periapical Pathology: A Split-Mouth Design and Survival Evaluation after 1-Year Follow-Up.

    PubMed

    Hita-Iglesias, Cristina; Sánchez-Sánchez, Francisco J; Montero, Javier; Galindo-Moreno, Pablo; Mesa, Francisco; Martínez-Lara, Ildefonso; Sánchez-Fernández, Elena

    2016-12-01

    To compare the immediate implant success rates between sites with chronic apical lesions and healthy sites in the same patients 1 year postdelayed loading. One hundred sixty-eight immediate implants were placed in sixty patients at upper incisor, canine, and premolar sites. A split-mouth design was used, placing a minimum of two implants, one in a fresh socket associated with chronic periapical disease, the average lesion size was larger than 4 mm and less than 8 mm (test group), and the other(s) in a healthy fresh socket (control group). Implant survival rate at 1 year postloading delayed was compared between the groups. The implant survival rate was 98.2% for the total sample (n = 168); out of the three implants lost, two were from the test group, and one was from the control group (in the same patient as one of the former). Among the surviving implants, five were also considered failures due to excessive bone loss (n = 3) and also because of the recurrence of the periapical lesions (n = 2). Survival rates were significantly lower in the test than control sites at 12 months postloading. Implant survival rates were significantly lower after the immediate implantation in postextraction sockets associated with chronic periapical disease (90.8%) than in healthy postextraction sockets (98.1%). © 2015 Wiley Periodicals, Inc.

  3. The immediate placement of dental implants into extraction sites with periapical lesions: a retrospective chart review.

    PubMed

    Bell, Christopher Lincoln; Diehl, David; Bell, Brian Michael; Bell, Robert E

    2011-06-01

    The purpose of this study was to evaluate the success of dental implants placed immediately into extraction sites in the presence of chronic periapical pathology. The charts of 655 patients who had implants immediately placed into fresh extraction sites were reviewed for the presence or absence of periapical radiolucencies. A total of 922 implants were included. Of the 922 implants, 285 were immediately placed into sockets that had chronic periapical infections. The remaining 637 implants, without signs of periapical pathology, were used as the control group. Success of the implants was defined as successful osseointegration, successful restoration, and absence of evidence of bone loss or peri-implantitis. Other variables such as age, gender, smoking, diabetes, bisphosphonate use, lucencies of adjacent teeth, and implant stability at the time of placement were also evaluated. Of the 922 implants, 285 were placed into sockets with periapical radiolucencies. The success rate of implants placed in the study group was 97.5%, whereas the success rate of the control group was 98.7%. The difference was not found to be statistically significant. The mean follow-up was 19.75 months, with a maximum of 93 months and a minimum of 3 months. A statistically higher failure rate was found for implants placed adjacent to retained teeth with periapical pathology. The placement of implants in sockets affected by chronic periapical pathology can be considered a safe and viable treatment option. There is a risk of implant failure when placing implants adjacent to teeth with periapical radiolucencies. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Local and systemic changes associated with long-term, percutaneous, static implantation with titanium alloys in rhesus macaques (Macaca mulatta)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frydman, Galit F.; Marini, Robert P.; Bakthavatchalu, Vasudevan

    Metal alloys are frequently used as implant materials in veterinary medicine. Recent studies suggest that many types of metal alloys may induce both local and systemic inflammatory responses. In this study, 37 rhesus macaques with long-term skull-anchored percutaneous titanium alloy implants (0-14 years duration) were evaluated for changes in their hematology, coagulation and serum chemistry profiles. Negative controls (n=28) did not have implants. All of the implanted animals were on IACUC-approved protocols and were not implanted for the purpose of this study. Animals with implants had significantly higher plasma D-dimer and lower antithrombin III concentrations compared with nonimplanted animals (p-valuesmore » < 0.05). Additionally, animals with implants had significantly higher globulin, and lower albumin and calcium concentrations compared with nonimplanted animals (p-values < 0.05). Many of these changes were positively correlated with duration of implantation as well as the number of implants. Chronic bacterial infection was observed on the skin around many of the implant sites, and within deeper tissues. Representative histopathology around the implant site of two implanted animals revealed chronic suppurative to pyogranulomatous inflammation extending from the skin to the dura mater. X-ray fluorescence microscopy of tissue biopsies from the implant site of the same two animals revealed significant increases in free metal ions within the tissue, including titanium and iron. Free metal ions persisted in the tissues up to 6 months postexplant. These results suggest that long-term skull-anchored percutaneous titanium alloy implants results in localized inflammation, chronic infection, and leaching of metal ions into local tissues.« less

  5. Power-efficient production of photon pairs in a tapered chalcogenide microwire

    NASA Astrophysics Data System (ADS)

    Meyer-Scott, Evan; Dot, Audrey; Ahmad, Raja; Li, Lizhu; Rochette, Martin; Jennewein, Thomas

    2015-02-01

    Using tapered fibers of As2Se3 chalcogenide glass, we produce photon pairs at telecommunication wavelengths with low pump powers. We found maximum coincidences-to-accidentals ratios of 2.13 ± 0.07 for degenerate pumping with 3.2 μW average power, and 1.33 ± 0.03 for non-degenerate pumping with 1.0 μW and 1.5 μW average power of the two pumps. Our results show that the ultrahigh nonlinearity in these microwires could allow single-photon pumping to produce photon pairs, enabling the production of large entangled states, heralding of single photons after lossy transmission, and photonic quantum information processing with nonlinear optics.

  6. Tuning temperature and size of hot spots and hot-spot arrays.

    PubMed

    Saïdi, Elika; Babinet, Nicolas; Lalouat, Loïc; Lesueur, Jérôme; Aigouy, Lionel; Volz, Sébastian; Labéguerie-Egéa, Jessica; Mortier, Michel

    2011-01-17

    By using scanning thermal microscopy, it is shown that nanoscale constrictions in metallic microwires deposited on an oxidized silicon substrate can be tuned in terms of temperature and confinement size. High-resolution temperature maps indeed show that submicrometer hot spots and hot-spot arrays are obtained when the SiO(2) layer thickness decreases below 100 nm. When the SiO(2) thickness becomes larger, heat is less confined in the vicinity of the constrictions and laterally spreads all along the microwire. These results are in good agreement with numerical simulations, which provide dependences between silica-layer thickness and nanodot shape and temperature. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Retrieval of the Leadless Cardiac Pacemaker: A Multicenter Experience.

    PubMed

    Reddy, Vivek Y; Miller, Marc A; Knops, Reinoud E; Neuzil, Petr; Defaye, Pascal; Jung, Werner; Doshi, Rahul; Castellani, Mark; Strickberger, Adam; Mead, R Hardwin; Doppalapudi, Harish; Lakkireddy, Dhanunjaya; Bennett, Matthew; Sperzel, Johannes

    2016-12-01

    Leadless cardiac pacemakers have emerged as a safe and effective alternative to conventional transvenous single-chamber ventricular pacemakers. Herein, we report a multicenter experience on the feasibility and safety of acute retrieval (<6 weeks) and chronic retrieval (>6 weeks) of the leadless cardiac pacemaker in humans. This study included patients enrolled in 3 multicenter trials, who received a leadless cardiac pacemaker implant and who subsequently underwent a device removal attempt. The overall leadless pacemaker retrieval success rate was 94%: for patients whose leadless cardiac pacemaker had been implanted for <6 weeks (acute retrieval cohort), complete retrieval was achieved in 100% (n=5/5); for those implanted for ≥ 6 weeks (chronic retrieval cohort), retrieval was achieved in 91% (n=10/11) of patients. The mean duration of time from implant to retrieval attempt was 346 days (range, 88-1188 days) in the chronic retrieval cohort, and nearly two thirds (n=7; 63%) had been implanted for >6 months before the retrieval attempt. There were no procedure-related adverse events at 30 days post retrieval procedure. This multicenter experience demonstrated the feasibility and safety of retrieving a chronically implanted single-chamber (right ventricle) active fixation leadless pacemaker. URL: https://www.clinicaltrials.gov. Unique identifiers: NCT02051972, NCT02030418, and NCT01700244. © 2016 American Heart Association, Inc.

  8. Analysis of RANKL gene polymorphism (rs9533156 and rs2277438) in Iranian patients with chronic periodontitis and periimplantitis.

    PubMed

    Kadkhodazadeh, Mahdi; Ebadian, Ahmad Reza; Gholami, Gholam Ali; Khosravi, Alireza; Tabari, Zahra Alizadeh

    2013-05-01

    RANK/OPG/RANKL pathway plays a significant role in osteoclastogenesis, osteoclast activation, and regulation of bone resorption. The aim of this study was to investigate the association of RANKL gene polymorphisms (rs9533156 and rs2277438) with chronic periodontitis and peri-implantitis in an Iranian population. 77 patients with chronic periodontitis, 40 patients with peri-implantitis and 89 periodontally healthy patients were enrolled in this study. 5cc of blood was obtained from the cephalic vein of subjects arms and transferred into tubes containing EDTA. Genomic DNA was extracted using Miller's Salting Out technique. The DNA was transferred into 96 division plates, transported to Kbioscience Institute in United Kingdom and analyzed using the Kbioscience Competitive Allele Specific PCR (KASP) technique. Differences in the frequencies of genotypes and alleles in the disease and control groups were analyzed using Chi-square and Fisher's exact statistical tests. Comparison of frequency of alleles in SNP rs9533156 of RANKL gene between the chronic periodontitis group with the control and peri-implantitis groups revealed statistically significant differences (P=0.024 and P=0.027, respectively). Comparison of genotype expression of SNP rs9533156 on RANKL gene between the peri-implantitis group with chronic periodontitis and control groups revealed statistically significant differences (P=0.001); the prevalence of CT genotype was significantly higher amongst the chronic periodontitis group. Regarding SNP rs2277438 of RANKL gene, comparison of prevalence of genotypes and frequency of alleles did not reveal any significant differences (P=0.641/P=0.537, respectively). The results of this study indicate that CT genotype of rs9533156 RANKL gene polymorphism was significantly associated with peri-implantitis, and may be considered as a genetic determinant for peri-implantitis. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Development of an Electrochemical Paper-Based Analytical Device for Trace Detection of Virus Particles.

    PubMed

    Channon, Robert B; Yang, Yuanyuan; Feibelman, Kristen M; Geiss, Brian J; Dandy, David S; Henry, Charles S

    2018-06-19

    Viral pathogens are a serious health threat around the world, particularly in resource limited settings, where current sensing approaches are often insufficient and slow, compounding the spread and burden of these pathogens. Here, we describe a label-free, point-of-care approach toward detection of virus particles, based on a microfluidic paper-based analytical device with integrated microwire Au electrodes. The device is initially characterized through capturing of streptavidin modified nanoparticles by biotin-modified microwires. An order of magnitude improvement in detection limits is achieved through use of a microfluidic device over a classical static paper-based device, due to enhanced mass transport and capturing of particles on the modified electrodes. Electrochemical impedance spectroscopy detection of West Nile virus particles was carried out using antibody functionalized Au microwires, achieving a detection limit of 10.2 particles in 50 μL of cell culture media. No increase in signal is found on addition of an excess of a nonspecific target (Sindbis). This detection motif is significantly cheaper (∼$1 per test) and faster (∼30 min) than current methods, while achieving the desired selectivity and sensitivity. This sensing motif represents a general platform for trace detection of a wide range of biological pathogens.

  10. Radiation sensors based on GaN microwires

    NASA Astrophysics Data System (ADS)

    Verheij, D.; Peres, M.; Cardoso, S.; Alves, L. C.; Alves, E.; Durand, C.; Eymery, J.; Lorenz, K.

    2018-05-01

    GaN microwires were shown to possess promising characteristics as building blocks for radiation resistant particle detectors. They were grown by metal organic vapour phase epitaxy with diameters between 1 and 2 μm and lengths around 20 μm. Devices were fabricated by depositing gold contacts at the extremities of the wires using photolithography. The response of these single wire radiation sensors was then studied under irradiation with 2 MeV protons. Severe degradation of the majority of devices only sets in for fluences above protons cm‑2 revealing good radiation resistance. During proton irradiation, a clear albeit small current gain was observed with a corresponding decay time below 1 s. Photoconductivity measurements upon irradiation with UV light were carried out before and after the proton irradiation. Despite a relatively low gain, attributed to significant dark currents caused by a high dopant concentration, fast response times of a few seconds were achieved comparable to state-of-the-art GaN nanowire photodetectors. Irradiation and subsequent annealing resulted in an overall improvement of the devices regarding their response to UV radiation. The photocurrent gain increased compared to the values that were obtained prior to the irradiation, without compromising the decay times. The results indicate the possibility of using GaN microwires not only as UV detectors, but also as particle detectors.

  11. A silicon microwire under a three-dimensional anisotropic tensile stress

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji, Xiaoyu; Poilvert, Nicolas; Liu, Wenjun

    Three-dimensional tensile stress, or triaxial tensile stress, is difficult to achieve in a material. We present the investigation of an unusual three-dimensional anisotropic tensile stress field and its influence on the electronic properties of a single crystal silicon microwire. The microwire was created by laser heating an amorphous silicon wire deposited in a 1.7 μm silica glass capillary by high pressure chemical vapor deposition. Tensile strain arises due to the thermal expansion mismatch between silicon and silica. Synchrotron X-ray micro-beam Laue diffraction (μ-Laue) microscopy reveals that the three principal strain components are +0.47% (corresponding to a tensile stress of +0.7more » GPa) along the fiber axis and nearly isotropic +0.02% (corresponding to a tensile stress of +0.3 GPa) in the cross-sectional plane. This effect was accompanied with a reduction of 30 meV in the band gap energy of silicon, as predicted by the density-functional theory calculations and in close agreement with energy-dependent photoconductivity measurements. While silicon has been explored under many stress states, this study explores a stress state where all three principal stress components are tensile. Given the technological importance of silicon, the influence of such an unusual stress state on its electronic properties is of fundamental interest.« less

  12. Ultra-bright γ-ray flashes and dense attosecond positron bunches from two counter-propagating laser pulses irradiating a micro-wire target.

    PubMed

    Li, Han-Zhen; Yu, Tong-Pu; Hu, Li-Xiang; Yin, Yan; Zou, De-Bin; Liu, Jian-Xun; Wang, Wei-Quan; Hu, Shun; Shao, Fu-Qiu

    2017-09-04

    We propose a novel scheme to generate ultra-bright ultra-short γ-ray flashes and high-energy-density attosecond positron bunches by using multi-dimensional particle-in-cell simulations with quantum electrodynamics effects incorporated. By irradiating a 10 PW laser pulse with an intensity of 10 23 W/cm 2 onto a micro-wire target, surface electrons are dragged-out of the micro-wire and are effectively accelerated to several GeV energies by the laser ponderomotive force, forming relativistic attosecond electron bunches. When these electrons interact with the probe pulse from the other side, ultra-short γ-ray flashes are emitted with an ultra-high peak brightness of 1.8 × 10 24 photons s -1 mm -2 mrad -2 per 0.1%BW at 24 MeV. These photons propagate with a low divergence and collide with the probe pulse, triggering the Breit-Wheeler process. Dense attosecond e - e + pair bunches are produced with the positron energy density as high as 10 17 J/m 3 and number of 10 9 . Such ultra-bright ultra-short γ-ray flashes and secondary positron beams may have potential applications in fundamental physics, high-energy-density physics, applied science and laboratory astrophysics.

  13. Patterned Arrays of Functional Lateral Heterostructures via Sequential Template-Directed Printing.

    PubMed

    Li, Yifan; Su, Meng; Li, Zheng; Huang, Zhandong; Li, Fengyu; Pan, Qi; Ren, Wanjie; Hu, Xiaotian; Song, Yanlin

    2018-04-30

    The precise integration of microscale dots and lines with controllable interfacing connections is highly important for the fabrication of functional devices. To date, the solution-processible methods are used to fabricate the heterogeneous micropatterns for different materials. However, for increasingly miniaturized and multifunctional devices, it is extremely challenging to engineer the uncertain kinetics of a solution on the microstructures surfaces, resulting in uncontrollable interface connections and poor device performance. Here, a sequential template-directed printing process is demonstrated for the fabrication of arrayed microdots connected by microwires through the regulation of the Rayleigh-Taylor instability of material solution or suspension. Flexibility in the control of fluidic behaviors can realize precise interface connection between the micropatterns, including the microwires traversing, overlapping or connecting the microdots. Moreover, various morphologies such as circular, rhombic, or star-shaped microdots as well as straight, broken or curved microwires can be achieved. The lateral heterostructure printed with two different quantum dots displays bright dichromatic photoluminescence. The ammonia gas sensor printed by polyaniline and silver nanoparticles exhibits a rapid response time. This strategy can construct heterostructures in a facile manner by eliminating the uncertainty of the multimaterials interface connection, which will be promising for the development of novel lateral functional devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Rotation-Induced Macromolecular Spooling of DNA

    NASA Astrophysics Data System (ADS)

    Shendruk, Tyler N.; Sean, David; Berard, Daniel J.; Wolf, Julian; Dragoman, Justin; Battat, Sophie; Slater, Gary W.; Leslie, Sabrina R.

    2017-07-01

    Genetic information is stored in a linear sequence of base pairs; however, thermal fluctuations and complex DNA conformations such as folds and loops make it challenging to order genomic material for in vitro analysis. In this work, we discover that rotation-induced macromolecular spooling of DNA around a rotating microwire can monotonically order genomic bases, overcoming this challenge. We use single-molecule fluorescence microscopy to directly visualize long DNA strands deforming and elongating in shear flow near a rotating microwire, in agreement with numerical simulations. While untethered DNA is observed to elongate substantially, in agreement with our theory and numerical simulations, strong extension of DNA becomes possible by introducing tethering. For the case of tethered polymers, we show that increasing the rotation rate can deterministically spool a substantial portion of the chain into a fully stretched, single-file conformation. When applied to DNA, the fraction of genetic information sequentially ordered on the microwire surface will increase with the contour length, despite the increased entropy. This ability to handle long strands of DNA is in contrast to modern DNA sample preparation technologies for sequencing and mapping, which are typically restricted to comparatively short strands, resulting in challenges in reconstructing the genome. Thus, in addition to discovering new rotation-induced macromolecular dynamics, this work inspires new approaches to handling genomic-length DNA strands.

  15. Bilateral cochlear implantation in the ferret: A novel animal model for behavioral studies

    PubMed Central

    Hartley, Douglas E.H.; Vongpaisal, Tara; Xu, Jin; Shepherd, Robert K.; King, Andrew J.; Isaiah, Amal

    2010-01-01

    Bilateral cochlear implantation has recently been introduced with the aim of improving both speech perception in background noise and sound localization. Although evidence suggests that binaural perception is possible with two cochlear implants, results in humans are variable. To explore potential contributing factors to these variable outcomes, we have developed a behavioral animal model of bilateral cochlear implantation in a novel species, the ferret. Although ferrets are ideally suited to psychophysical and physiological assessments of binaural hearing, cochlear implantation has not been previously described in this species. This paper describes the techniques of deafening with aminoglycoside administration, surgical implantation of an intracochlear array and chronic intracochlear electrical stimulation with monitoring for electrode integrity and efficacy of stimulation. Experiments have been presented elsewhere to show that the model can be used to study behavioral and electrophysiological measures of binaural hearing in chronically implanted animals. This paper demonstrates that cochlear implantation and chronic intracochlear electrical stimulation are both safe and effective in ferrets, opening up the possibility of using this model to study potential protective effects of bilateral cochlear implantation on the developing central auditory pathway. Since ferrets can be used to assess psychophysical and physiological aspects of hearing along with the structure of the auditory pathway in the same animals, we anticipate that this model will help develop novel neuroprosthetic therapies for use in humans. PMID:20576507

  16. Real-time control of walking using recordings from dorsal root ganglia

    NASA Astrophysics Data System (ADS)

    Holinski, B. J.; Everaert, D. G.; Mushahwar, V. K.; Stein, R. B.

    2013-10-01

    Objective. The goal of this study was to decode sensory information from the dorsal root ganglia (DRG) in real time, and to use this information to adapt the control of unilateral stepping with a state-based control algorithm consisting of both feed-forward and feedback components. Approach. In five anesthetized cats, hind limb stepping on a walkway or treadmill was produced by patterned electrical stimulation of the spinal cord through implanted microwire arrays, while neuronal activity was recorded from the DRG. Different parameters, including distance and tilt of the vector between hip and limb endpoint, integrated gyroscope and ground reaction force were modelled from recorded neural firing rates. These models were then used for closed-loop feedback. Main results. Overall, firing-rate-based predictions of kinematic sensors (limb endpoint, integrated gyroscope) were the most accurate with variance accounted for >60% on average. Force prediction had the lowest prediction accuracy (48 ± 13%) but produced the greatest percentage of successful rule activations (96.3%) for stepping under closed-loop feedback control. The prediction of all sensor modalities degraded over time, with the exception of tilt. Significance. Sensory feedback from moving limbs would be a desirable component of any neuroprosthetic device designed to restore walking in people after a spinal cord injury. This study provides a proof-of-principle that real-time feedback from the DRG is possible and could form part of a fully implantable neuroprosthetic device with further development.

  17. Real-time control of walking using recordings from dorsal root ganglia

    PubMed Central

    Holinski, B J; Everaert, D G; Mushahwar, V K; Stein, R B

    2013-01-01

    Objective The goal of this study was to decode sensory information from the dorsal root ganglia (DRG) in real time, and to use this information to adapt the control of unilateral stepping with a state-based control algorithm consisting of both feed-forward and feedback components. Approach In five anesthetized cats, hind limb stepping on a walkway or treadmill was produced by patterned electrical stimulation of the spinal cord through implanted microwire arrays, while neuronal activity was recorded from the dorsal root ganglia. Different parameters, including distance and tilt of the vector between hip and limb endpoint, integrated gyroscope and ground reaction force were modeled from recorded neural firing rates. These models were then used for closed-loop feedback. Main Results Overall, firing-rate based predictions of kinematic sensors (limb endpoint, integrated gyroscope) were the most accurate with variance accounted for >60% on average. Force prediction had the lowest prediction accuracy (48±13%) but produced the greatest percentage of successful rule activations (96.3%) for stepping under closed-loop feedback control. The prediction of all sensor modalities degraded over time, with the exception of tilt. Significance Sensory feedback from moving limbs would be a desirable component of any neuroprosthetic device designed to restore walking in people after a spinal cord injury. This study provides a proof-of-principle that real-time feedback from the DRG is possible and could form part of a fully implantable neuroprosthetic device with further development. PMID:23928579

  18. Chronic post-operative iris prosthesis endophthalmitis in a patient with traumatic aniridia: a case report.

    PubMed

    Firl, Kevin C; Montezuma, Sandra R

    2016-11-09

    Post-operative endophthalmitis is a serious complication of intraocular surgery which may present acutely or chronically. Chronic post-operative endophthalmitis is characterized by decreased visual acuity, mild pain, and low-grade uveitis several weeks or months after intraocular surgery which may be responsive to corticosteroids, but recur upon tapering. Low virulence organisms such as Propionibacterium acnes are the most common culprit organisms, and treatment most often consists of both intravitreal antibiotic injections and surgery. Aniridia is a condition defined by total or partial loss of the iris and leads to decreased visual quality marked by glare and photophobia. Treatment of complex or severe cases of traumatic aniridia in which surgical repair is difficult may consist of implantation of iris prostheses, devices designed to reduce symptoms of aniridia. Though chronic, post-operative endophthalmitis has been associated with most intraocular surgeries including intraocular lens implantation after cataract removal, it has never been described in a patient with an iris prosthesis. In this case report, we describe the case of a 49 year old, male construction worker with traumatic aniridia who experienced chronic, recurrent low-grade intraocular inflammation and irritation for months after implantation of the Ophtec 311 prosthetic iris. Symptoms and signs of inflammation improved temporarily with sub-Tenon's capsule triamcinolone injections. Ultimately after more than 2 post-operative years, the iris prosthesis was explanted, and intravitreal cultures showed P. acnes growth after 5 days. Intravitreal antibiotics treated the infection successfully. To our knowledge, this is the first reported case of chronic, post-operative endophthalmitis in a patient with an iris prosthesis. Chronic, post-operative endophthalmitis may be a difficult to identify in the context of traumatic aniridia and iris prosthesis implantation due to other potential etiologies of chronic intraocular inflammation such as implant-induced chafing. Clinicians should suspect chronic, post-operative endophthalmitis in any case of recurrent, low-grade intraocular inflammation.

  19. Radial elemental and phase separation in Ni-Mn-Ga glass-coated microwires

    NASA Astrophysics Data System (ADS)

    Shevyrtalov, S.; Zhukov, A.; Medvedeva, S.; Lyatun, I.; Zhukova, V.; Rodionova, V.

    2018-05-01

    In this manuscript, radial elemental and phase separation in Ni-Mn-Ga glass-coated microwires with high excess Ni as a result of high-temperature annealing was observed. Partial manganese evaporation from the outer part of the metallic nucleus and glass melting results in the formation of manganese oxide at the surface. The lack of manganese due to its evaporation induces Ni3Ga formation in the intermediate part, while in the middle part of the metallic nucleus, the residual L21 phase with an average chemical composition of Ni60Mn9Ga31 remains. The layered structure exhibits soft ferromagnetic behavior below 270 K. The results were discussed taking into account the chemical composition, arising internal stresses, recrystallization, and atomic ordering.

  20. Implications of chronic daily anti-oxidant administration on the inflammatory response to intracortical microelectrodes

    NASA Astrophysics Data System (ADS)

    Potter-Baker, Kelsey A.; Stewart, Wade G.; Tomaszewski, William H.; Wong, Chun T.; Meador, William D.; Ziats, Nicholas P.; Capadona, Jeffrey R.

    2015-08-01

    Objective. Oxidative stress events have been implicated to occur and facilitate multiple failure modes of intracortical microelectrodes. The goal of the present study was to evaluate the ability of a sustained concentration of an anti-oxidant and to reduce oxidative stress-mediated neurodegeneration for the application of intracortical microelectrodes. Approach. Non-functional microelectrodes were implanted into the cortex of male Sprague Dawley rats for up to sixteen weeks. Half of the animals received a daily intraperitoneal injection of the natural anti-oxidant resveratrol, at 30 mg kg-1. The study was designed to investigate the biodistribution of the resveratrol, and the effects on neuroinflammation/neuroprotection following device implantation. Main results. Daily maintenance of a sustained range of resveratrol throughout the implantation period resulted in fewer degenerating neurons in comparison to control animals at both two and sixteen weeks post implantation. Initial and chronic improvements in neuronal viability in resveratrol-dosed animals were correlated with significant reductions in local superoxide anion accumulation around the implanted device at two weeks after implantation. Controls, receiving only saline injections, were also found to have reduced amounts of accumulated superoxide anion locally and less neurodegeneration than controls at sixteen weeks post-implantation. Despite observed benefits, thread-like adhesions were found between the liver and diaphragm in resveratrol-dosed animals. Significance. Overall, our chronic daily anti-oxidant dosing scheme resulted in improvements in neuronal viability surrounding implanted microelectrodes, which could result in improved device performance. However, due to the discovery of thread-like adhesions, further work is still required to optimize a chronic anti-oxidant dosing regime for the application of intracortical microelectrodes.

  1. Clinical peri-implant sounding accuracy in the presence of chronic inflammation of peri-implant tissues. Clinical observation study.

    PubMed

    Romeo, E; Lops, D; Storelli, S; Ghisolfi, M

    2009-03-01

    The aim of this study was to assess if the probing pocket depth is a reliable clinical parameter in the evaluation of the depth of the peri-implant sulci. In case of chronic inflamed peri-implant tissues, this evaluation is useful for understanding the level of bone resorption. The study enrolled 22 patients. All of them were diagnosed for a peri-implantitis and were scheduled for a resective surgery with implantoplasty. During the surgery, a full thickness flap was raised and resective surgery was performed as well as an implantoplasty procedure. Peri-implant probing values before the surgery (PAL) were recorded, as were values of bone resorption after flap elevation (DIB), at all four sites around each implant (88 sites). The mean value of PAL calculated for all 88 sites was 5.67 mm (+/-1.46); the correspondent value of DIB was 6.37 mm (+/-1.81). In 52 sites out of 88 (59.1%) the values of PAL and DIB were exactly the same (maximum difference 0.5 mm). In only 10 cases (11.3%) the difference between PAL and DIB was >2 mm. The mean values for PAL and DIB were not statistically different. Authors have concluded that in case of chronic inflammation of peri-implant tissues, the probe reaches the bone pick, allowing the clinician to have reliable information on the actual bone resorption.

  2. A simple device for exteriorizing chronically implanted catheters in dogs.

    PubMed

    Butterfield, J L; Decker, G E

    1984-04-01

    A device, consisting of a round base and cap made of polytetrafluoroethylene, was made to exteriorize and protect chronically implanted arterial and venous catheters in conscious dogs. In experiments lasting as long as 9 months, the subcutaneously implanted button-like appliance did not cause tissue reactions and was well tolerated by 98% of a group of 200 dogs. Being maintenance-free, having the capacity to exteriorize several catheter or wire outputs, and needing no protective harness were advantages of the device.

  3. Wireless, High-Bandwidth Recordings from Non-Human Primate Motor Cortex using a Scalable 16-Ch Implantable Microsystem

    PubMed Central

    Borton, David A.; Song, Yoon-Kyu; Patterson, William R.; Bull, Christopher W.; Park, Sunmee; Laiwalla, Farah; Donoghue, John P.; Nurmikko, Arto V.

    2013-01-01

    A multitude of neuroengineering challenges exist today in creating practical, chronic multichannel neural recording systems for primate research and human clinical application. Specifically, a) the persistent wired connections limit patient mobility from the recording system, b) the transfer of high bandwidth signals to external (even distant) electronics normally forces premature data reduction, and c) the chronic susceptibility to infection due to the percutaneous nature of the implants all severely hinder the success of neural prosthetic systems. Here we detail one approach to overcome these limitations: an entirely implantable, wirelessly communicating, integrated neural recording microsystem, dubbed the Brain Implantable Chip (BIC). PMID:19964128

  4. Histological Evaluation of a Chronically-implanted Electrocorticographic Electrode Grid in a Non-human Primate

    PubMed Central

    Degenhart, Alan D.; Eles, James; Dum, Richard; Mischel, Jessica L.; Smalianchuk, Ivan; Endler, Bridget; Ashmore, Robin C.; Tyler-Kabara, Elizabeth C.; Hatsopoulos, Nicholas G.; Wang, Wei; Batista, Aaron P.; Cui, X. Tracy

    2016-01-01

    Electrocorticography (ECoG), used as a neural recording modality for brain-machine interfaces (BMIs), potentially allows for field potentials to be recorded from the surface of the cerebral cortex for long durations without suffering the host-tissue reaction to the extent that it is common with intracortical microelectrodes. Though the stability of signals obtained from chronically-implanted ECoG electrodes has begun receiving attention, to date little work has characterized the effects of long-term implantation of ECoG electrodes on underlying cortical tissue. We implanted a high-density ECoG electrode grid subdurally over cortical motor areas of a Rhesus macaque for 666 days. Histological analysis revealed minimal damage to the cortex underneath the implant, though the grid itself was encapsulated in collagenous tissue. We observed macrophages and foreign body giant cells at the tissue-array interface, indicative of a stereotypical foreign body response. Despite this encapsulation, cortical modulation during reaching movements was observed more than 18 months post-implantation. These results suggest that ECoG may provide a means by which stable chronic cortical recordings can be obtained with comparatively little tissue damage, facilitating the development of clinically-viable brain-machine interface systems. PMID:27351722

  5. Histological evaluation of a chronically-implanted electrocorticographic electrode grid in a non-human primate

    NASA Astrophysics Data System (ADS)

    Degenhart, Alan D.; Eles, James; Dum, Richard; Mischel, Jessica L.; Smalianchuk, Ivan; Endler, Bridget; Ashmore, Robin C.; Tyler-Kabara, Elizabeth C.; Hatsopoulos, Nicholas G.; Wang, Wei; Batista, Aaron P.; Cui, X. Tracy

    2016-08-01

    Objective. Electrocorticography (ECoG), used as a neural recording modality for brain-machine interfaces (BMIs), potentially allows for field potentials to be recorded from the surface of the cerebral cortex for long durations without suffering the host-tissue reaction to the extent that it is common with intracortical microelectrodes. Though the stability of signals obtained from chronically implanted ECoG electrodes has begun receiving attention, to date little work has characterized the effects of long-term implantation of ECoG electrodes on underlying cortical tissue. Approach. We implanted and recorded from a high-density ECoG electrode grid subdurally over cortical motor areas of a Rhesus macaque for 666 d. Main results. Histological analysis revealed minimal damage to the cortex underneath the implant, though the grid itself was encapsulated in collagenous tissue. We observed macrophages and foreign body giant cells at the tissue-array interface, indicative of a stereotypical foreign body response. Despite this encapsulation, cortical modulation during reaching movements was observed more than 18 months post-implantation. Significance. These results suggest that ECoG may provide a means by which stable chronic cortical recordings can be obtained with comparatively little tissue damage, facilitating the development of clinically viable BMI systems.

  6. Effect of Mechanical Stresses and Annealing on the Magnetic Structure and the Magnetic Impedance of Amorphous CoFeSiBCr Microwires

    NASA Astrophysics Data System (ADS)

    Nematov, M. G.; Salem, M. M.; Azim, U.; Akhmat, M.; Morchenko, A. T.; Yudanov, N. A.; Panina, L. V.

    2018-02-01

    The structural and magnetic properties of amorphous ferromagnetic microwires can undergo significant measurements under the action of external mechanical stresses and heat treatment. The study of transformations occurring in this case is important for designing various sensors of mechanical stresses, loading, and temperature and also for inducing in the wires a certain type of magnetic anisotropy that plays a significant role in the realization of various effects in them. In this work, the influence of external stresses and annealing on the processes of the magnetization and the magnetic impedance of Co71Fe5B11Si10Cr3 microwires having a low positive magnetostriction ( 10-8) in amorphous state has been studied. The influence of external stresses leads to a sharp change in the character of the magnetization reversal curve, which was due to the change in the sign of the magnetostriction and the type of magnetic anisotropy. The amplitude of higher harmonics and the value of the magnetic impedance, respectively, are sensitive to mechanical stresses. Elastic stresses in the wires with a partial crystallization do not lead to a marked change in the magnetic properties; however, annealing can lead to a substantial increase in the axial magnetic anisotropy of the wires existing in the stressed state. The experimental results are analyzed in the framework of a magnetostriction model of induced magnetic anisotropy.

  7. In Vivo Validation of Custom-Designed Silicon-Based Microelectrode Arrays for Long-Term Neural Recording and Stimulation

    PubMed Central

    Manoonkitiwongsa, Panya S.; Wang, Cindy X.; McCreery, Douglas B.

    2012-01-01

    We developed and validated silicon-based neural probes for neural stimulating and recording in long-term implantation in the brain. The probes combine the deep reactive ion etching process and mechanical shaping of their tip region, yielding a mechanically sturdy shank with a sharpened tip to reduce insertion force into the brain and spinal cord, particularly, with multiple shanks in the same array. The arrays’ insertion forces have been quantified in vitro. Five consecutive chronically-implanted devices were fully functional from 3 to 18 months. The microelectrode sites were electroplated with iridium oxide, and the charge injection capacity measurements were performed both in vitro and after implantation in the adult feline brain. The functionality of the chronic array was validated by stimulating in the cochlear nucleus and recording the evoked neuronal activity in the central nucleus of the inferior colliculus. The arrays’ recording quality has also been quantified in vivo with neuronal spike activity recorded up to 566 days after implantation. Histopathology evaluation of neurons and astrocytes using immunohistochemical stains indicated minimal alterations of tissue architecture after chronic implantation. PMID:22020666

  8. Decoding bipedal locomotion from the rat sensorimotor cortex

    NASA Astrophysics Data System (ADS)

    Rigosa, J.; Panarese, A.; Dominici, N.; Friedli, L.; van den Brand, R.; Carpaneto, J.; DiGiovanna, J.; Courtine, G.; Micera, S.

    2015-10-01

    Objective. Decoding forelimb movements from the firing activity of cortical neurons has been interfaced with robotic and prosthetic systems to replace lost upper limb functions in humans. Despite the potential of this approach to improve locomotion and facilitate gait rehabilitation, decoding lower limb movement from the motor cortex has received comparatively little attention. Here, we performed experiments to identify the type and amount of information that can be decoded from neuronal ensemble activity in the hindlimb area of the rat motor cortex during bipedal locomotor tasks. Approach. Rats were trained to stand, step on a treadmill, walk overground and climb staircases in a bipedal posture. To impose this gait, the rats were secured in a robotic interface that provided support against the direction of gravity and in the mediolateral direction, but behaved transparently in the forward direction. After completion of training, rats were chronically implanted with a micro-wire array spanning the left hindlimb motor cortex to record single and multi-unit activity, and bipolar electrodes into 10 muscles of the right hindlimb to monitor electromyographic signals. Whole-body kinematics, muscle activity, and neural signals were simultaneously recorded during execution of the trained tasks over multiple days of testing. Hindlimb kinematics, muscle activity, gait phases, and locomotor tasks were decoded using offline classification algorithms. Main results. We found that the stance and swing phases of gait and the locomotor tasks were detected with accuracies as robust as 90% in all rats. Decoded hindlimb kinematics and muscle activity exhibited a larger variability across rats and tasks. Significance. Our study shows that the rodent motor cortex contains useful information for lower limb neuroprosthetic development. However, brain-machine interfaces estimating gait phases or locomotor behaviors, instead of continuous variables such as limb joint positions or speeds, are likely to provide more robust control strategies for the design of such neuroprostheses.

  9. Auditory inhibitory gating in medial prefrontal cortex: Single unit and local field potential analysis.

    PubMed

    Mears, R P; Klein, A C; Cromwell, H C

    2006-08-11

    Medial prefrontal cortex is a crucial region involved in inhibitory processes. Damage to the medial prefrontal cortex can lead to loss of normal inhibitory control over motor, sensory, emotional and cognitive functions. The goal of the present study was to examine the basic properties of inhibitory gating in this brain region in rats. Inhibitory gating has recently been proposed as a neurophysiological assay for sensory filters in higher brain regions that potentially enable or disable information throughput. This perspective has important clinical relevance due to the findings that gating is dramatically impaired in individuals with emotional and cognitive impairments (i.e. schizophrenia). We used the standard inhibitory gating two-tone paradigm with a 500 ms interval between tones and a 10 s interval between tone pairs. We recorded both single unit and local field potentials from chronic microwire arrays implanted in the medial prefrontal cortex. We investigated short-term (within session) and long-term (between session) variability of auditory gating and additionally examined how altering the interval between the tones influenced the potency of the inhibition. The local field potentials displayed greater variability with a reduction in the amplitudes of the tone responses over both the short and long-term time windows. The decrease across sessions was most intense for the second tone response (test tone) leading to a more robust gating (lower T/C ratio). Surprisingly, single unit responses of different varieties retained similar levels of auditory responsiveness and inhibition in both the short and long-term analysis. Neural inhibition decreased monotonically related to the increase in intertone interval. This change in gating was most consistent in the local field potentials. Subsets of single unit responses did not show the lack of inhibition even for the longer intertone intervals tested (4 s interval). These findings support the idea that the medial prefrontal cortex is an important site where early inhibitory functions reside and potentially mediate psychological processes.

  10. Seeded Nanowire and Microwire Growth from Lithium Alloys.

    PubMed

    Han, Sang Yun; Boebinger, Matthew G; Kondekar, Neha P; Worthy, Trevor J; McDowell, Matthew T

    2018-06-06

    Although vapor-liquid-solid (VLS) growth of nanowires from alloy seed particles is common in various semiconductor systems, related wire growth in all-metal systems is rare. Here, we report the spontaneous growth of nano- and microwires from metal seed particles during the cooling of Li-rich bulk alloys containing Au, Ag, or In. The as-grown wires feature Au-, Ag-, or In-rich metal tips and LiOH shafts; the results indicate that the wires grow as Li metal and are converted to polycrystalline LiOH during and/or after growth due to exposure to H 2 O and O 2 . This new process is a simple way to create nanostructures, and the findings suggest that metal nanowire growth from alloy seeds is possible in a variety of systems.

  11. Enhancement of Giant Magneto-Impedance in Series Co-Rich Microwires for Low-Field Sensing Applications

    NASA Astrophysics Data System (ADS)

    Jiang, S. D.; Eggers, T.; Thiabgoh, O.; Xing, D. W.; Fang, W. B.; Sun, J. F.; Srikanth, H.; Phan, M. H.

    2018-02-01

    Two soft ferromagnetic Co68.25Fe4.25Si12.25B15.25 microwires with the same diameter of 50 ± 1 μm but different fabrication processes were placed in series and in parallel circuit configurations to investigate their giant magneto-impedance (GMI) responses in a frequency range of 1-100 MHz for low-field sensing applications. We show that, while the low-field GMI response is significantly reduced in the parallel configuration, it is greatly enhanced in the series connection. These results suggest that a highly sensitive GMI sensor can be designed by arranging multi-wires in a saw-shaped fashion to optimize the sensing area, and soldered together in series connection to maintain the excellent magnetic field sensitivity.

  12. Temperature Effects on the Magnetization and Magnetoimpedance in Ferromagnetic Glass-Covered microwires

    NASA Astrophysics Data System (ADS)

    Uddin, A.; Evstigneeva, S. A.; Dzhumazoda, A.; Salem, M. M.; Nematov, M. G.; Adam, A. M.; Panina, LV; Morchenko, A. T.

    2017-11-01

    The effect of temperature on static and dynamic magnetization in Co-based amorphous microwires was investigated with the aim of potential applications in miniature temperature sensors. The wires of two compositions with different magnetostriction and Curie temperature in glass-cover and after removing the glass layer demonstrated very different temperature behaviour of the magnetization loops and magnetoimpedance. The mechanisms of the temperature effects are related to the residual stress distribution due to fast solidification, the difference in thermal expansion coefficient of metal and glass and the proximity to the Curie temperature. The interplay of these factors may result in a very strong temperature dependence of magnetoimpedance in a moderate temperature range (room temperature -373K). Such elements may be incorporated in various composite materials for a local temperature monitoring.

  13. The use of tungsten as a chronically implanted material.

    PubMed

    Shah Idil, A; Donaldson, N

    2018-04-01

    This review paper shows that tungsten should not generally be used as a chronically implanted material. The metal has a long implant history, from neuroscience, vascular medicine, radiography, orthopaedics, prosthodontics, and various other fields, primarily as a result of its high density, radiopacity, tensile strength, and yield point. However, a crucial material criterion for chronically implanted metals is their long-term resistance to corrosion in body fluids, either by inherently noble metallic surfaces, or by protective passivation layers of metal oxide. The latter is often assumed for elemental tungsten, with references to its 'inertness' and 'stability' common in the literature. This review argues that in the body, metallic tungsten fails this criterion, and will eventually dissolve into the soluble hexavalent form W 6+ , typically represented by the orthotungstate [Formula: see text] (monomeric tungstate) anion. This paper outlines the metal's unfavourable corrosion thermodynamics in the human physiological environment, the chemical pathways to either metallic or metal oxide dissolution, the rate-limiting steps, and the corrosion-accelerating effects of reactive oxidising species that the immune system produces post-implantation. Multiple examples of implant corrosion have been reported, with failure by dissolution to varying extents up to total loss, with associated emission of tungstate ions and elevated blood serum levels measured. The possible toxicity of these corrosion products has also been explored. As the field of medical implants grows and designers explore novel solutions to medical implant problems, the authors recommend the use of alternative materials.

  14. The use of tungsten as a chronically implanted material

    NASA Astrophysics Data System (ADS)

    Shah Idil, A.; Donaldson, N.

    2018-04-01

    This review paper shows that tungsten should not generally be used as a chronically implanted material. The metal has a long implant history, from neuroscience, vascular medicine, radiography, orthopaedics, prosthodontics, and various other fields, primarily as a result of its high density, radiopacity, tensile strength, and yield point. However, a crucial material criterion for chronically implanted metals is their long-term resistance to corrosion in body fluids, either by inherently noble metallic surfaces, or by protective passivation layers of metal oxide. The latter is often assumed for elemental tungsten, with references to its ‘inertness’ and ‘stability’ common in the literature. This review argues that in the body, metallic tungsten fails this criterion, and will eventually dissolve into the soluble hexavalent form W6+, typically represented by the orthotungstate WO42- (monomeric tungstate) anion. This paper outlines the metal’s unfavourable corrosion thermodynamics in the human physiological environment, the chemical pathways to either metallic or metal oxide dissolution, the rate-limiting steps, and the corrosion-accelerating effects of reactive oxidising species that the immune system produces post-implantation. Multiple examples of implant corrosion have been reported, with failure by dissolution to varying extents up to total loss, with associated emission of tungstate ions and elevated blood serum levels measured. The possible toxicity of these corrosion products has also been explored. As the field of medical implants grows and designers explore novel solutions to medical implant problems, the authors recommend the use of alternative materials.

  15. Possible sources of neuroprotection following subretinal silicon chip implantation in RCS rats

    NASA Astrophysics Data System (ADS)

    Pardue, Machelle T.; Phillips, Michael J.; Yin, Hang; Fernandes, Alcides; Cheng, Yian; Chow, Alan Y.; Ball, Sherry L.

    2005-03-01

    Current retinal prosthetics are designed to stimulate existing neural circuits in diseased retinas to create a visual signal. However, implantation of retinal prosthetics may create a neurotrophic environment that also leads to improvements in visual function. Possible sources of increased neuroprotective effects on the retina may arise from electrical activity generated by the prosthetic, mechanical injury due to surgical implantation, and/or presence of a chronic foreign body. This study evaluates these three neuroprotective sources by implanting Royal College of Surgeons (RCS) rats, a model of retinitis pigmentosa, with a subretinal implant at an early stage of photoreceptor degeneration. Treatment groups included rats implanted with active and inactive devices, as well as sham-operated. These groups were compared to unoperated controls. Evaluation of retinal function throughout an 18 week post-implantation period demonstrated transient functional improvements in eyes implanted with an inactive device at 6, 12 and 14 weeks post-implantation. However, the number of photoreceptors located directly over or around the implant or sham incision was significantly increased in eyes implanted with an active or inactive device or sham-operated. These results indicate that in the RCS rat localized neuroprotection of photoreceptors from mechanical injury or a chronic foreign body may provide similar results to subretinal electrical stimulation at the current output evaluated here.

  16. Sinus floor elevation from a maxillary molar tooth extraction socket in a patient with chronic inflammation.

    PubMed

    Tözüm, Tolga F; Dursun, Erhan; Tulunoglu, Ibrahim

    2009-03-01

    The compromised nature of the residual interradicular bone after extraction of periodontally hopeless maxillary molars often requires a sinus elevation procedure to ideally place the implants to accept future prosthesis. Maxillary sinus elevation surgery is a procedure used to increase the volume of bone mass so that dental implants can be placed. This article documents a sinus floor elevation technique through an extraction socket in a 65-year-old white male with chronic inflammation to increase the bone mass after the extraction of a periodontally involved maxillary molar tooth. Computerized tomography revealed an increased thickness of the sinus membrane, which was attributed to possible chronic sinus inflammation and periodontal inflammation. After consultation with the Department of Otolaryngology, it was diagnosed as chronic inflammation without any contraindication for sinus elevation surgery or implant placement. One month after the extraction, the sinus floor elevation surgery was performed through the extraction socket, and implants were placed 4 months later. An uneventful healing was noted after 6 months of osseointegration; two porcelain-fused-to-metal crowns were fabricated. Clinical follow-up took place every 3 months for 3 years, and successful healing was achieved. The patient was satisfied with the esthetic and functional results of the oral rehabilitation. Sinus floor elevation through an extraction socket without any residual bone, followed by dental implant placement, provided successful functional results and acceptable stability.

  17. Utilization of multiple spinal cord stimulation (SCS) waveforms in chronic pain patients.

    PubMed

    Berg, Anthony P; Mekel-Bobrov, Nitzan; Goldberg, Edward; Huynh, Dat; Jain, Roshini

    2017-08-01

    Advances in spinal cord stimulation (SCS) have improved patient outcomes, leading to its increased utilization for chronic pain. Chronic pain is dynamic showing exacerbations, variable severity, and evolving pain patterns. Given this complexity, SCS systems that provide a broad range of stimulation waveforms may be valuable. The aim of this research was to characterize the usage pattern of stimulation waveforms and field shapes in chronic pain patients implanted with the Spectra System. A review of daily device usage in a cohort of 250 patients implanted for a minimum duration of one month was conducted. With follow-ups ranging between 1 month and 1 year post-implant, 72.8% of patients used Standard Rate, 34.8% Anode Intensification, 23.2% Higher Rate, and 8.4% Burst stimulation waveforms. Collectively, 60% used 1 or more advanced waveforms, either exclusively or along with Standard Rate. A trend showed patients continuing to use up to 3 programs one year post-implant. When given a choice, SCS patients often utilize a variety of waveforms, suggesting that patients may benefit from a single system that provides multiple waveforms and field shapes to customize therapy and improve efficacy.

  18. Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces

    PubMed Central

    Kozai, Takashi D. Yoshida; Langhals, Nicholas B.; Patel, Paras R.; Deng, Xiaopei; Zhang, Huanan; Smith, Karen L.; Lahann, Joerg; Kotov, Nicholas A.; Kipke, Daryl R.

    2012-01-01

    Implantable neural microelectrodes that can record extracellular biopotentials from small, targeted groups of neurons are critical for neuroscience research and emerging clinical applications including brain-controlled prosthetic devices. The crucial material-dependent problem is developing microelectrodes that record neural activity from the same neurons for years with high fidelity and reliability. Here, we report the development of an integrated composite electrode consisting of a carbon-fibre core, a poly(p-xylylene)-based thin-film coating that acts as a dielectric barrier and that is functionalized to control intrinsic biological processes, and a poly(thiophene)-based recording pad. The resulting implants are an order of magnitude smaller than traditional recording electrodes, and more mechanically compliant with brain tissue. They were found to elicit much reduced chronic reactive tissue responses and enabled single-neuron recording in acute and early chronic experiments in rats. This technology, taking advantage of new composites, makes possible highly selective and stealthy neural interface devices towards realizing long-lasting implants. PMID:23142839

  19. Fabrication of 3D solenoid microcoils in silica glass by femtosecond laser wet etch and microsolidics

    NASA Astrophysics Data System (ADS)

    Meng, Xiangwei; Yang, Qing; Chen, Feng; Shan, Chao; Liu, Keyin; Li, Yanyang; Bian, Hao; Du, Guangqing; Hou, Xun

    2015-02-01

    This paper reports a flexible fabrication method for 3D solenoid microcoils in silica glass. The method consists of femtosecond laser wet etching (FLWE) and microsolidics process. The 3D microchannel with high aspect ratio is fabricated by an improved FLWE method. In the microsolidics process, an alloy was chosen as the conductive metal. The microwires are achieved by injecting liquid alloy into the microchannel, and allowing the alloy to cool and solidify. The alloy microwires with high melting point can overcome the limitation of working temperature and improve the electrical property. The geometry, the height and diameter of microcoils were flexibly fabricated by the pre-designed laser writing path, the laser power and etching time. The 3D microcoils can provide uniform magnetic field and be widely integrated in many magnetic microsystems.

  20. A novel reciprocating micropump based on Lorentz force

    NASA Astrophysics Data System (ADS)

    Salari, Alinaghi; Hakimsima, Abbas; Shafii, Mohammad Behshad

    2015-03-01

    Lorentz force is the pumping basis of many electromagnetic micropumps used in lab-on-a-chip. In this paper a novel reciprocating single-chamber micropump is proposed, in which the actuation technique is based on Lorentz force acting on an array of microwires attached on a membrane surface. An alternating current is applied through the microwires in the presence of a magnetic field. The resultant force causes the membrane to oscillate and pushes the fluid to flow through microchannel using a ball-valve. The pump chamber (3 mm depth) was fabricated on a Polymethylmethacrylate (PMMA) substrate using laser engraving technique. The chamber was covered by a 60 μm thick hyper-elastic latex rubber diaphragm. Two miniature permanent magnets capable of providing magnetic field of 0.09 T at the center of the diaphragm were mounted on each side of the chamber. Square wave electric current with low-frequencies was generated using a function generator. Cylindrical copper microwires (250 μm diameter and 5 mm length) were attached side-by-side on top surface of the diaphragm. Thin loosely attached wires were used as connectors to energize the electrodes. Due to large displacement length of the diaphragm (~3 mm) a high efficiency (~90%) ball valve (2 mm diameter stainless steel ball in a tapered tubing structure) was used in the pump outlet. The micropump exhibits a flow rate as high as 490 μl/s and pressure up to 1.5 kPa showing that the pump is categorized among high-flow-rate mechanical micropumps.

  1. Tailoring the magnetic properties of new Fe-Ni-Co-Al-(Ta,Nb)-B superelastic rapidly quenched microwires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borza, F., E-mail: fborza@phys-iasi.ro; Lupu, N.; Dobrea, V.

    2015-05-07

    Ferromagnetic Fe-Ni-Co-Al-(Ta,Nb)-B microwires with diameters from 170 μm to 50 μm, which possess both superelastic and good magnetic properties, have been prepared by rapid quenching from the melt using the in rotating water spinning technique followed by cold-drawing and ageing. The cold-drawing and annealing processes lead to the initialization of premartensitic phases as confirmed by the X-ray diffraction and scanning transmission electron microscopic investigations, more significantly in the 50 μm cold-drawn microwires. An increase in the coercive field and in the saturation magnetization has been obtained by annealing, more importantly in the case of Nb-containing alloy. Ageing by thermal or current annealing ledmore » to the initialization of the superelastic effect. High values of strain of up to 1.8%, very good repeatability under successive loading, and values of superelastic effect of up to 1.2% have been achieved. The structural analysis coupled with the stress-strain data suggests that these materials annealed at 800 °C have superelastic potential at reduced ageing times. The magnetic behavior was found to be easily tailored through both thermal and thermomagnetic treatments with changes in the magnetic parameters which can be contactless detected. The results are important for future applications where both mechanical and magnetic properties matter, i.e., sensing/actuating systems.« less

  2. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis.

    PubMed

    Hamada, Yusuke; Prabhu, Srividya; John, Vanchit

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as "erratic healing," may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.

  3. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis

    PubMed Central

    Prabhu, Srividya

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as “erratic healing,” may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications. PMID:27807485

  4. A good preoperative response to transcutaneous electrical nerve stimulation predicts a better therapeutic effect of implanted occipital nerve stimulation in pharmacologically intractable headaches.

    PubMed

    Nguyen, Jean-Paul; Nizard, Julien; Kuhn, Emmanuelle; Carduner, Florence; Penverne, Frédérique; Verleysen-Robin, Marie-Christine; Terreaux, Luc; de Gaalon, Solène; Raoul, Sylvie; Lefaucheur, Jean-Pascal

    2016-02-01

    Occipital nerve stimulation (ONS) is a surgical approach to treat patients with medically intractable chronic headache disorders. However, no preoperative test has been yet validated to allow candidates to be selected for implantation. In this study, the analgesic efficacy of transcutaneous electrical nerve stimulation (TENS) was tested for 1 to 3 months in 41 patients with pharmacologically intractable headache disorders of various origins, using a new technique of electrode placement over the occipital nerve. ONS electrodes were subsequently implanted in 33 patients (occipital neuralgia [n=15], cervicogenic headache [n=7], cluster headache [n=6], chronic migraine [n=5]) who had responded at least moderately to TENS. Assessment was performed up to five years after implantation (three years on average), based on the mean and maximum daily pain intensity scored on a 0-10 visual analogue scale and the number of headache days per month. Both TENS and chronic ONS therapy were found to be efficacious (57-76% improvement compared to baseline on the various clinical variables). The efficacy of ONS was better in cases of good or very good preoperative response to TENS than in cases of moderate response to TENS. Implanted ONS may be a valuable therapeutic option in the long term for patients with pharmacologically intractable chronic headache. Although we cannot conclude in patients with poor or no response to TENS, a good or very good response to TENS can support the indication of ONS therapy. This preoperative test could particularly be useful in patients with chronic migraine, in whom it may be difficult to indicate an invasive technique of cranial neurostimulation. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. Improvement of renal function after human umbilical cord mesenchymal stem cell treatment on chronic renal failure and thoracic spinal cord entrapment: a case report.

    PubMed

    Rahyussalim, Ahmad Jabir; Saleh, Ifran; Kurniawati, Tri; Lutfi, Andi Praja Wira Yudha

    2017-11-30

    Chronic renal failure is an important clinical problem with significant socioeconomic impact worldwide. Thoracic spinal cord entrapment induced by a metabolic yield deposit in patients with renal failure results in intrusion of nervous tissue and consequently loss of motor and sensory function. Human umbilical cord mesenchymal stem cells are immune naïve and they are able to differentiate into other phenotypes, including the neural lineage. Over the past decade, advances in the field of regenerative medicine allowed development of cell therapies suitable for kidney repair. Mesenchymal stem cell studies in animal models of chronic renal failure have uncovered a unique potential of these cells for improving function and regenerating the damaged kidney. We report a case of a 62-year-old ethnic Indonesian woman previously diagnosed as having thoracic spinal cord entrapment with paraplegic condition and chronic renal failure on hemodialysis. She had diabetes mellitus that affected her kidneys and had chronic renal failure for 2 years, with creatinine level of 11 mg/dl, and no urinating since then. She was treated with human umbilical cord mesenchymal stem cell implantation protocol. This protocol consists of implantation of 16 million human umbilical cord mesenchymal stem cells intrathecally and 16 million human umbilical cord mesenchymal stem cells intravenously. Three weeks after first intrathecal and intravenous implantation she could move her toes and her kidney improved. Her creatinine level decreased to 9 mg/dl. Now after 8 months she can raise her legs and her creatinine level is 2 mg/dl with normal urinating. Human umbilical cord mesenchymal stem cell implantations led to significant improvement for spinal cord entrapment and kidney failure. The major histocompatibility in allogeneic implantation is an important issue to be addressed in the future.

  6. The role of flexible polymer interconnects in chronic tissue response induced by intracortical microelectrodes--a modeling and an in vivo study.

    PubMed

    Subbaroyan, Jeyakumar; Kipke, Daryl R

    2006-01-01

    Chronic tissue response induced by tethering is one of the major causes for implant failure in intracortical microelectrodes. In this study, we had explored the hypothesis that flexible interconnects could provide strain relief against forces of "micromotion" and hence could result in maintaining a healthy tissue surrounding the implant. Finite element modeling results indicated that flexible interconnects, namely polyimide (E=2 GPa) and polydimethylsiloxane (PDMS, E=6 MPa), reduced the interfacial strain by 66% and two orders of magnitude, respectively. Quantitative immunohistochemistry results indicated that significant neuronal loss occurred up to 60 mum from the implant interface. This was strongly correlated to both glial fibrillary acidic protein (GFAP) expression and simulated strain as a function of distance away from the implant.

  7. The adult brain tissue response to hollow fiber membranes of varying surface architecture with or without cotransplanted cells

    NASA Astrophysics Data System (ADS)

    Zhang, Ning

    A variety of biomaterials have been chronically implanted into the central nervous system (CNS) for repair or therapeutic purposes. Regardless of the application, chronic implantation of materials into the CNS induces injury and elicits a wound healing response, eventually leading to the formation of a dense extracellular matrix (ECM)-rich scar tissue that is associated with the segregation of implanted materials from the surrounding normal tissue. Often this reaction results in impaired performance of indwelling CNS devices. In order to enhance the performance of biomaterial-based implantable devices in the CNS, this thesis investigated whether adult brain tissue response to implanted biomaterials could be manipulated by changing biomaterial surface properties or further by utilizing the biology of co-transplanted cells. Specifically, the adult rat brain tissue response to chronically implanted poly(acrylonitrile-vinylchloride) (PAN-PVC) hollow fiber membranes (HFMs) of varying surface architecture were examined temporally at 2, 4, and 12 weeks postimplantation. Significant differences were discovered in the brain tissue response to the PAN-PVC HFMs of varying surface architecture at 4 and 12 weeks. To extend this work, whether the soluble factors derived from a co-transplanted cellular component further affect the brain tissue response to an implanted HFM in a significant way was critically exploited. The cells used were astrocytes, whose ability to influence scar formation process following CNS injury by physical contact with the host tissue had been documented in the literature. Data indicated for the first time that astrocyte-derived soluble factors ameliorate the adult brain tissue reactivity toward HFM implants in an age-dependent manner. While immature astrocytes secreted soluble factors that suppressed the brain tissue reactivity around the implants, mature astrocytes secreted factors that enhanced the gliotic response. These findings prove the feasibility of ameliorating the CNS tissue reactivity toward biomaterials implants by varying biomaterial surface properties or incorporating scar-reductive factors derived from functional cells into implant constructs, therefore, provide guidance in the design of more integrative biomaterial-based implantable devices for CNS repair.

  8. Electric field-induced reversible trapping of microtubules along metallic glass microwire electrodes

    NASA Astrophysics Data System (ADS)

    Kim, Kyongwan; Sikora, Aurélien; Nakayama, Koji S.; Umetsu, Mitsuo; Hwang, Wonmuk; Teizer, Winfried

    2015-04-01

    Microtubules are among bio-polymers providing vital functions in dynamic cellular processes. Artificial organization of these bio-polymers is a requirement for transferring their native functions into device applications. Using electrophoresis, we achieve an accumulation of microtubules along a metallic glass (Pd42.5Cu30Ni7.5P20) microwire in solution. According to an estimate based on migration velocities of microtubules approaching the wire, the electrophoretic mobility of microtubules is around 10-12 m2/Vs. This value is four orders of magnitude smaller than the typical mobility reported previously. Fluorescence microscopy at the individual-microtubule level shows microtubules aligning along the wire axis during the electric field-induced migration. Casein-treated electrodes are effective to reversibly release trapped microtubules upon removal of the external field. An additional result is the condensation of secondary filamentous structures from oriented microtubules.

  9. Nanowires precisely grown on the ends of microwire electrodes permit the recording of intracellular action potentials within deeper neural structures

    PubMed Central

    Ferguson, John E; Boldt, Christopher; Puhl, Joshua G; Stigen, Tyler W; Jackson, Jadin C; Crisp, Kevin M; Mesce, Karen A; Netoff, Theoden I; Redish, A David

    2012-01-01

    Aims Nanoelectrodes are an emerging biomedical technology that can be used to record intracellular membrane potentials from neurons while causing minimal damage during membrane penetration. Current nanoelectrode designs, however, have low aspect ratios or large substrates and thus are not suitable for recording from neurons deep within complex natural structures, such as brain slices. Materials & methods We describe a novel nanoelectrode design that uses nanowires grown on the ends of microwire recording electrodes similar to those frequently used in vivo. Results & discussion We demonstrate that these nanowires can record intracellular action potentials in a rat brain slice preparation and in isolated leech ganglia. Conclusion Nanoelectrodes have the potential to revolutionize intracellular recording methods in complex neural tissues, to enable new multielectrode array technologies and, ultimately, to be used to record intracellular signals in vivo. PMID:22475650

  10. Embroidered Copper Microwire Current Collector for Improved Cycling Performance of Silicon Anodes in Lithium-Ion Batteries.

    PubMed

    Breitung, Ben; Aguiló-Aguayo, Noemí; Bechtold, Thomas; Hahn, Horst; Janek, Jürgen; Brezesinski, Torsten

    2017-10-12

    Si holds great promise as an alloying anode material for Li-ion batteries with improved energy density because of its high theoretical specific capacity and favorable operation voltage range. However, the large volume expansion of Si during electrochemical reaction with Li and the associated adverse effects strongly limit its prospect for application. Here, we report on the use of three-dimensional instead of flat current collectors for high-capacity Si anodes in an attempt to mitigate the loss of electrical contact of active electrode regions as a result of structural disintegration with cycling. The current collectors were produced by technical embroidery and consist of interconnected Cu wires of diameter <150 µm. In comparison to Si/Li cells using a conventional Cu foil current collector, the embroidered microwire network-based cells show much enhanced capacity and reversibility due to a higher degree of tolerance to cycling.

  11. Computer-aided design and experimental investigation of a hydrodynamic device: the microwire electrode

    PubMed

    Fulian; Gooch; Fisher; Stevens; Compton

    2000-08-01

    The development and application of a new electrochemical device using a computer-aided design strategy is reported. This novel design is based on the flow of electrolyte solution past a microwire electrode situated centrally within a large duct. In the design stage, finite element simulations were employed to evaluate feasible working geometries and mass transport rates. The computer-optimized designs were then exploited to construct experimental devices. Steady-state voltammetric measurements were performed for a reversible one-electron-transfer reaction to establish the experimental relationship between electrolysis current and solution velocity. The experimental results are compared to those predicted numerically, and good agreement is found. The numerical studies are also used to establish an empirical relationship between the mass transport limited current and the volume flow rate, providing a simple and quantitative alternative for workers who would prefer to exploit this device without the need to develop the numerical aspects.

  12. Integrating Patient-Controlled Analgesia Using Implanted Intrathecal Pumps for Postoperative Pain Management: A Case Report.

    PubMed

    Peniche, Alec; Poree, Lawrence; Schumacher, Mark; Yu, Xiaobing

    2018-06-01

    Intrathecal patient-controlled analgesia (IT-PCA) through implanted intrathecal infusion pumps has been increasingly utilized for severe cancer and chronic noncancer pain management. However, its application for acute postoperative pain management has not been reported to date. We present a case of a patient with an implanted intrathecal pump for chronic nonmalignant back pain who underwent an extensive spinal fusion surgery. The IT-PCA functionality of her intrathecal pump was successfully integrated into her postoperative multimodal pain regimen. Hence, IT-PCA can be safely incorporated into acute postoperative pain management with vigilant monitoring and close multidisciplinary collaboration.

  13. 21 CFR 882.5830 - Implanted diaphragmatic/phrenic nerve stimulator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... which an abnormally low amount of air enters the lungs) caused by brain stem disease, high cervical spinal cord injury, or chronic lung disease. The stimulator consists of an implanted receiver with...

  14. 21 CFR 882.5830 - Implanted diaphragmatic/phrenic nerve stimulator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... which an abnormally low amount of air enters the lungs) caused by brain stem disease, high cervical spinal cord injury, or chronic lung disease. The stimulator consists of an implanted receiver with...

  15. 21 CFR 882.5830 - Implanted diaphragmatic/phrenic nerve stimulator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... which an abnormally low amount of air enters the lungs) caused by brain stem disease, high cervical spinal cord injury, or chronic lung disease. The stimulator consists of an implanted receiver with...

  16. Histological analysis of soft and hard tissues in a periimplantitis lesion: a human case report.

    PubMed

    Jung, Soong-Ryong; Bashutski, Jill D; Jandali, Rami; Prasad, Hari; Rohrer, Michael; Wang, Hom-Lay

    2012-06-01

    Little is known regarding the histologic hard and soft tissue changes that occur in chronic periimplantitis situations in humans. It is critical to gain an understanding of all aspects of periimplantitis to develop appropriate therapeutic approaches. An 83-year-old African American man presented with a fractured implant affected by severe, chronic periimplantitis and surrounded by keratinized gingiva. A trephine biopsy of the implant and surrounding tissues was analyzed histologically. Histological analysis of the periimplantitis specimen revealed significant inflammatory infiltrate consisting predominantly of lymphocytes and plasma cells. In addition, epithelial migration and bone loss to the apical vent were noted. This case report documents a single case of periimplantitis that was left untreated for 7 years. The presence of significant keratinized tissue and a smooth surface implant failed to prevent fibrous encapsulation of the implant.

  17. Effects of small increases in corticosterone levels on morphology, immune function, and feather development.

    PubMed

    Butler, Michael W; Leppert, Lynda L; Dufty, Alfred M

    2010-01-01

    Stressors encountered during avian development may affect an individual's phenotype, including immunocompetence, growth, and feather quality. We examined effects of simulated chronic low-level stress on American kestrel (Falco sparverius) nestlings. Continuous release of corticosterone, a hormone involved in the stress response, can model chronic stress in birds. We implanted 13-d-old males with either corticosterone-filled implants or shams and measured their growth, immune function, and feather coloration. We found no significant differences between groups at the end of the weeklong exposure period in morphometrics (mass, tarsus, wing length, and asymmetry), immunocompetence (cutaneous immunity, heterophil/lymphocyte ratio, and humoral immunity), or feather coloration. One week subsequent to implant removal, however, differences were detected. Sham-implanted birds had significantly longer wings and a reduced level of cutaneous immune function compared with those of birds given corticosterone-filled implants. Therefore, increases of only 2 ng/mL in basal corticosterone titer can have small but measurable effects on subsequent avian development.

  18. Biodegradable Magnesium (Mg) Implantation Does Not Impose Related Metabolic Disorders in Rats with Chronic Renal Failure

    PubMed Central

    Wang, Jiali; Xu, Jiankun; Liu, Waiching; Li, Yangde; Qin, Ling

    2016-01-01

    Mg and its alloys have been considered as one of the most promising biodegradable medical devices, but it was still unclear whether hypermagnesemia involved health risks would occur in persons with kidney disease due to their deteriorated kidney function for Mg ions excretion from their body. In this study, we established a chronic renal failure (CRF) model in rats induced by adenine administration prior to Mg implantation, aiming to predict if CRF patients are suitable for the use of Mg implants. The results showed that Mg levels in serum, urine, feces and internal organs had no significant changes after Mg implantation for both normal and CRF rats. Biochemical indices detection and histopathological analysis in kidney, liver and heart tissue confirmed that Mg implants did not induce any extra damage in animals even with renal failure. Our study indicates that Mg based orthopaedic medical device may be considered for use in CRF patients without biosafety concerns. PMID:27210744

  19. [Cochlear implantation through the middle fossa approach].

    PubMed

    Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M

    2001-01-01

    The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.

  20. Biodegradable Magnesium (Mg) Implantation Does Not Impose Related Metabolic Disorders in Rats with Chronic Renal Failure

    NASA Astrophysics Data System (ADS)

    Wang, Jiali; Xu, Jiankun; Liu, Waiching; Li, Yangde; Qin, Ling

    2016-05-01

    Mg and its alloys have been considered as one of the most promising biodegradable medical devices, but it was still unclear whether hypermagnesemia involved health risks would occur in persons with kidney disease due to their deteriorated kidney function for Mg ions excretion from their body. In this study, we established a chronic renal failure (CRF) model in rats induced by adenine administration prior to Mg implantation, aiming to predict if CRF patients are suitable for the use of Mg implants. The results showed that Mg levels in serum, urine, feces and internal organs had no significant changes after Mg implantation for both normal and CRF rats. Biochemical indices detection and histopathological analysis in kidney, liver and heart tissue confirmed that Mg implants did not induce any extra damage in animals even with renal failure. Our study indicates that Mg based orthopaedic medical device may be considered for use in CRF patients without biosafety concerns.

  1. Low-power wireless micromanometer system for acute and chronic bladder-pressure monitoring.

    PubMed

    Majerus, Steve J A; Fletter, Paul C; Damaser, Margot S; Garverick, Steven L

    2011-03-01

    This letter describes the design, fabrication, and testing of a wireless bladder-pressure-sensing system for chronic, point-of-care applications, such as urodynamics or closed-loop neuromodulation. The system consists of a miniature implantable device and an external RF receiver and wireless battery charger. The implant is small enough to be cystoscopically implanted within the bladder wall, where it is securely held and shielded from the urine stream. The implant consists of a custom application-specific integrated circuit (ASIC), a pressure transducer, a rechargeable battery, and wireless telemetry and recharging antennas. The ASIC includes instrumentation, wireless transmission, and power-management circuitry, and on an average draws less than 9 μA from the 3.6-V battery. The battery charge can be wirelessly replenished with daily 6-h recharge periods that can occur during the periods of sleep. Acute in vivo evaluation of the pressure-sensing system in canine models has demonstrated that the system can accurately capture lumen pressure from a submucosal implant location.

  2. Bilateral chronic sacral neuromodulation for treatment of lower urinary tract dysfunction.

    PubMed

    Hohenfellner, M; Schultz-Lampel, D; Dahms, S; Matzel, K; Thüroff, J W

    1998-09-01

    Chronic sacral neuromodulation aims at functional restoration of selected forms of nonneurogenic and neurogenic bladder dysfunction. The original technique, as described by Tanagho and Schmidt, provides unilateral sacral nerve stimulation via an implanted stimulator powering an electrode inserted into a sacral foramen. Its drawback was that the implant failed unpredictably in some patients despite previous successful percutaneous test stimulation. Therefore, we modified the stimulation technique to improve the efficacy of chronic sacral neuromodulation. Guarded bipolar electrodes powered by an implantable neurostimulator were attached bilaterally directly to the S3 nerves through a sacral laminectomy in 9 women and 2 men (mean age 43.4 years). Of the patients 5 had urinary incontinence due to detrusor hyperactivity and 6 had urinary retention from detrusor hypocontractility. Mean followup with repeated urodynamics was 13 months (range 9 to 28). Four significant complications were encountered in 4 patients. In 10 patients the urological sequelae of the neurological disorder were alleviated significantly (50% or more), including 5 who experienced complete relief of symptoms. The efficacy of chronic sacral neuromodulation can be improved by bilateral attachment of electrodes directly to the sacral nerves.

  3. Long-term moderate elevation of corticosterone facilitates avian food-caching behaviour and enhances spatial memory.

    PubMed

    Pravosudov, Vladimir V

    2003-12-22

    It is widely assumed that chronic stress and corresponding chronic elevations of glucocorticoid levels have deleterious effects on animals' brain functions such as learning and memory. Some animals, however, appear to maintain moderately elevated levels of glucocorticoids over long periods of time under natural energetically demanding conditions, and it is not clear whether such chronic but moderate elevations may be adaptive. I implanted wild-caught food-caching mountain chickadees (Poecile gambeli), which rely at least in part on spatial memory to find their caches, with 90-day continuous time-release corticosterone pellets designed to approximately double the baseline corticosterone levels. Corticosterone-implanted birds cached and consumed significantly more food and showed more efficient cache recovery and superior spatial memory performance compared with placebo-implanted birds. Thus, contrary to prevailing assumptions, long-term moderate elevations of corticosterone appear to enhance spatial memory in food-caching mountain chickadees. These results suggest that moderate chronic elevation of corticosterone may serve as an adaptation to unpredictable environments by facilitating feeding and food-caching behaviour and by improving cache-retrieval efficiency in food-caching birds.

  4. Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses

    NASA Astrophysics Data System (ADS)

    Potter, Kelsey A.; Buck, Amy C.; Self, Wade K.; Capadona, Jeffrey R.

    2012-08-01

    An estimated 25 million people in the US alone rely on implanted medical devices, ˜2.5 million implanted within the nervous system. Even though many devices perform adequately for years, the host response to medical devices often severely limits tissue integration and long-term performance. This host response is believed to be particularly limiting in the case of intracortical microelectrodes, where it has been shown that glial cell encapsulation and localized neuronal cell loss accompany intracortical microelectrode implantation. Since neuronal ensembles must be within ˜50 µm of the electrode to obtain neuronal spikes and local field potentials, developing a better understanding of the molecular and cellular environment at the device-tissue interface has been the subject of significant research. Unfortunately, immunohistochemical studies of scar maturation in correlation to device function have been inconclusive. Therefore, here we present a detailed quantitative study of the cellular events and the stability of the blood-brain barrier (BBB) following intracortical microelectrode implantation and cortical stab injury in a chronic survival model. We found two distinctly inverse multiphasic profiles for neuronal survival in device-implanted tissue compared to stab-injured animals. For chronically implanted animals, we observed a biphasic paradigm between blood-derived/trauma-induced and CNS-derived inflammatory markers driving neurodegeneration at the interface. In contrast, stab injured animals demonstrated a CNS-mediated neurodegenerative environment. Collectively these data provide valuable insight to the possibility of multiple roles of chronic neuroinflammatory events on BBB disruption and localized neurodegeneration, while also suggesting the importance to consider multiphasic neuroinflammatory kinetics in the design of therapeutic strategies for stabilizing neural interfaces.

  5. Subcutaneous chronic implantable defibrillation systems in humans.

    PubMed

    Cappato, Riccardo; Smith, Warren M; Hood, Margaret A; Crozier, Ian G; Jordaens, Luc; Spitzer, Stefan G; Ardashev, Andrey V; Boersma, Lucas; Lupo, Pierpaolo; Grace, Andrew A; Bardy, Gust H

    2012-09-01

    The recent introduction of subcutaneous implantable cardioverter defibrillator (S-ICD) has raised attention about the potential of this technology for clinical use in daily clinical practice. We review the methods and results of the four studies conducted in humans for approval of this innovative technology for daily practice. Two studies using a temporary S-ICD system (acute human studies) were conducted to search for an appropriate lead configuration and energy requirements. For this purpose, 4 S-ICD configurations were tested in 78 patients at the time of transvenous (TV)-ICD implantation. The optimal configuration was tested in 49 more patients to comparatively assess the subcutaneous defibrillation threshold (S-DFT) versus the standard TV-ICD. Long-term implants were evaluated in 55 patients using an implanted system (chronic human study). The acute humans studies led to an optimal S-ICD configuration comprising a parasternal electrode and left anterolateral thoracic pulse generator. Both configurations successfully terminated 98% of induced ventricular fibrillation (VF), but significantly higher energy levels were required with S-ICD than with TV-ICD systems (36.6 ± 19.8 J vs. 11.1 ± 8.5 J). In the chronic study, all 137 VF episodes induced at time of implant were detected with a 98% conversion rate. Two pocket infections and four lead revisions were required during 10 ± 1 months of follow-up. During this period, survival was 98%, and 12 spontaneous ventricular tachyarrhythmias were detected and treated by the device. These data show that the S-ICD systems here consistently detected and converted VF induced at time of implant as well as sustained ventricular tachyarrhythmias occurring during follow-up (248).

  6. Haptoglobin gene polymorphisms in peri-implantitis and chronic periodontitis.

    PubMed

    Ebadian, Ahmad R; Kadkhodazadeh, Mahdi; Naghavi, Seyed Hamid Hosseini; Torshabi, Maryam; Tamizi, Mahmood

    2014-05-01

    The haptoglobin-hemoglobin (Hp-Hb) complex plays a significant role in regulating immune responses and acts as a bacteriostatic agent. Haptoglobin polymorphisms result in different Hb binding affinities. This study sought to assess whether Hp 2-2 could be a genetic determinant for increasing the risk of peri-implantitis and chronic periodontitis. Of the Iranian subjects referred to the Department of Periodontics, Shahid Beheshti University, Tehran, 203 were entered into the study, including 117 patients and 86 periodontally healthy individuals. Polymerase chain reaction (PCR) was performed for genotyping. Data were analyzed by Kruskal-Wallis test using the SPSS statistics software package. The prevalence of Hp 2-2, 2-1, and 1-1 did not differ significantly between patients and healthy subjects (P > 0.05). The highest frequencies of Hp 1-1, 2-1, and 2-2 genotypes were seen in the control (7%), peri-implantitis (51%) and periodontitis (64%) groups, respectively. Haptoglobin polymorphisms may not play a role in development of peri-implantitis or chronic periodontitis among Iranians but we strongly suggest researchers to evaluate this polymorphism in further studies on larger sample sizes, different populations, and other types of periodontitis. © 2013 Wiley Publishing Asia Pty Ltd.

  7. Chronic ovine evaluation of a totally implantable electrical left ventricular assist system.

    PubMed

    Ramasamy, N; Chen, H; Miller, P J; Jassawalla, J S; Greene, B A; Ocampo, A; Siegel, L C; Oyer, P E; Portner, P M

    1989-01-01

    The totally implantable Novacor left ventricular assist system (LVAS) comprises a pump/drive unit (VAD), electronic control and power subsystem (ECP), variable volume compensator (VVC), and belt skin transformer (BST). The system is now undergoing chronic in vivo evaluation. Cumulative animal testing of VAD, VVC, and BST subsystems are 12.1, 4.9, and 43 years, respectively. The longest implants were 279 days for the VAD, 767 days for the VVC, and 1,148 days for the BST. A chronic implant of the total system was electively terminated at 260 days. The LVAS was powered via the BST. Continuously monitored hemodynamic and pump parameters have demonstrated normal hemodynamics and LVAS operation. Periodic VVC determinations suggest a 0.8 ml/day diffusive gas loss. Tether-free operation has been demonstrated with an Ag-Zn battery backpack. The animal was healthy and free of infection as indicated by routine hematologic, biochemical and serum enzyme determinations. Hemolysis is minimal (plasma free hemoglobin less than 5 mg%). Pump output ranged from 7 to 8 L/min. Severe valve calcification was the reason for elective termination at 260 days. This preclinical in vivo experience, and in vitro reliability studies, demonstrate efficacy of the total system.

  8. MiR146a and MiR499 gene polymorphisms in Iranian periodontitis and peri-implantitis patients.

    PubMed

    Kadkhodazadeh, Mahdi; Jafari, Ali Reza; Amid, Reza; Ebadian, Ahmad Reza; Alipour, Marjan Mohammad; Mollaverdi, Fatemeh; Lafzi, Ardeshir

    2013-01-01

    MicroRNAs (MiRs) are small noncoding RNAs that are involved in protein translation, osteoclastogenesis, and immunoregulation. Peri-implantitis and chronic periodontitis are multifactorial diseases. They are the consequence of complex interactions among host response, genetics, and environment. In the present study, we aimed to investigate the possible association between MiR146a/MiR499 gene polymorphisms and periodontitis/peri-implantitis as a first report in oral implantology. From 197 individuals referred to Periodontology Department of Shahid Beheshti Dental School, three groups were enrolled in the assessment: 75 patients in the chronic periodontitis (CP) group, 38 patients in the peri-implantitis (PI) group, and 84 healthy subjects. DNA was extracted from fresh blood samples from the arm veins of participants and transferred to KBiosience Institute (Hoddesdon, United Kingdom) for genotyping. Chi-squared and Kruskal-Wallis tests were performed using SPSS software v.19 for statistical analyses. P-value < 0.05 was considered significant. The genotype frequencies in MiR 146a and MiR 499 were significantly different among the three groups. MiR146a (rs2910146) and MiR499 (rs3746444) gene polymorphisms may be genetic determinants for increased risk of chronic periodontitis and peri-implantitis in Iranians. More studies with larger sample sizes in different populations are necessary for determining the effect of these SNPs.

  9. Does cochlear implantation and electrical stimulation affect residual hair cells and spiral ganglion neurons?

    PubMed Central

    Coco, Anne; Epp, Stephanie B.; Fallon, James B.; Xu, Jin; Millard, Rodney E.; Shepherd, Robert K.

    2007-01-01

    Increasing numbers of cochlear implant subjects have some level of residual hearing at the time of implantation. The present study examined whether (i) hair cells that have survived one pathological insult (aminoglycoside deafening), can survive and function following long-term cochlear implantation and electrical stimulation (ES); and (ii) chronic ES in these cochleae results in greater trophic support of spiral ganglion neurons (SGNs) compared with cochleae devoid of hair cells. Eight cats, with either partial (n=4) or severe (n=4) sensorineural hearing loss, were bilaterally implanted with scala tympani electrode arrays 2 months after deafening, and received unilateral ES using charge balanced biphasic current pulses for periods of up to 235 days. Frequency-specific compound action potentials and click-evoked auditory brainstem responses (ABRs) were recorded periodically to monitor the residual acoustic hearing. Electrically-evoked ABRs (EABRs) were recorded to confirm the stimulus levels were 3-6 dB above the EABR threshold. On completion of the ES program the cochleae were examined histologically. Partially deafened animals showed no significant increase in acoustic thresholds over the implantation period. Moreover, chronic ES of an electrode array located in the base of the cochlea did not adversely affect hair cells in the middle or apical turns. There was evidence of a small but statistically significant rescue of SGNs in the middle and apical turns of stimulated cochleae in animals with partial hearing. Chronic ES did not, however, prevent a reduction in SGN density for the severely deaf cohort, although SGNs adjacent to the stimulating electrodes did exhibit a significant increase in soma area (p<0.01). In sum, chronic ES in partial hearing animals does not adversely affect functioning residual hair cells apical to the electrode array. Moreover, while there is an increase in the soma area of SGNs close to the stimulating electrodes in severely deaf cochleae, this trophic effect does not result in increased SGN survival. PMID:17258411

  10. A chronic scheme of cranial window preparation to study pial vascular reactivity in murine cerebral malaria

    PubMed Central

    Ong, Peng Kai; Meays, Diana; Frangos, John A.; Carvalho, Leonardo J.M.

    2013-01-01

    Objective The acute implantation of a cranial window for studying cerebroarteriolar reactivity in living animals involves a highly surgically-invasive craniotomy procedure at the time of experimentation, which limits its application in severely ill animals such as in the experimental murine model of cerebral malaria (ECM). To overcome this problem, a chronic window implantation scheme was designed and implemented. Methods A partial craniotomy is first performed by creating a skull bone flap in the healthy mice, which are then left to recover for 1–2 weeks, followed by infection to induce ECM. Uninfected animals are utilized as control. When cranial superfusion is needed, the bone flap is retracted and window implantation completed by assembling a perfusion chamber for compound delivery to the exposed brain surface. The presurgical step is intended to minimize surgical trauma on the day of experimentation. Results Chronic preparations in uninfected mice exhibited remarkably improved stability over acute ones by significantly reducing periarteriolar tissue damage and enhancing cerebroarteriolar dilator responses. The chronic scheme was successfully implemented in ECM mice which unveiled novel preliminary insights on impaired cerebroarteriolar reactivity and eNOS dysfunction. Conclusion The chronic scheme presents an innovative approach for advancing our mechanistic understanding on cerebrovascular dysfunction in ECM. PMID:23279271

  11. The upregulation of specific interleukin (IL) receptor antagonists and paradoxical enhancement of neuronal apoptosis due to electrode induced strain and brain micromotion.

    PubMed

    Karumbaiah, Lohitash; Norman, Sharon E; Rajan, Nithish B; Anand, Sanjay; Saxena, Tarun; Betancur, Martha; Patkar, Radhika; Bellamkonda, Ravi V

    2012-09-01

    The high mechanical mismatch between stiffness of silicon and metal microelectrodes and soft cortical tissue, induces strain at the neural interface which likely contributes to failure of the neural interface. However, little is known about the molecular outcomes of electrode induced low-magnitude strain (1-5%) on primary astrocytes, microglia and neurons. In this study we simulated brain micromotion at the electrode-brain interface by subjecting astrocytes, microglia and primary cortical neurons to low-magnitude cyclical strain using a biaxial stretch device, and investigated the molecular outcomes of induced strain in vitro. In addition, we explored the functional consequence of astrocytic and microglial strain on neural health, when they are themselves subjected to strain. Quantitative real-time PCR array (qRT-PCR Array) analysis of stretched astrocytes and microglia showed strain specific upregulation of an Interleukin receptor antagonist - IL-36Ra (previously IL-1F5), to ≈ 1018 and ≈ 236 fold respectively. Further, IL-36Ra gene expression remained unchanged in astrocytes and microglia treated with bacterial lipopolysaccharide (LPS) indicating that the observed upregulation in stretched astrocytes and microglia is potentially strain specific. Zymogram and western blot analysis revealed that mechanically strained astrocytes and microglia upregulated matrix metalloproteinases (MMPs) 2 and 9, and other markers of reactive gliosis such as glial fibrillary acidic protein (GFAP) and neurocan when compared to controls. Primary cortical neurons when stretched with and without IL-36Ra, showed a ≈ 400 fold downregulation of tumor necrosis factor receptor superfamily, member 11b (TNFRSF11b). Significant upregulation of members of the caspase cysteine proteinase family and other pro-apoptotic genes was also observed in the presence of IL-36Ra than in the absence of IL-36Ra. Adult rats when implanted with microwire electrodes showed upregulation of IL-36Ra (≈ 20 fold) and IL-1Ra (≈ 1500 fold) 3 days post-implantation (3 DPI), corroborating in vitro results, although these transcripts were drastically down regulated by ≈ 20 fold and ≈ 1488 fold relative to expression levels 3 DPI, at the end of 12 weeks post-implantation (12 WPI). These results demonstrate that IL receptor antagonists may be negatively contributing to neuronal health at acute time-points post-electrode implantation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Subclavian steal: Endovascular treatment of total occlusions of the subclavian artery using a retrograde transradial subintimal approach

    PubMed Central

    Golwala, Sohil N; Vance, Ansar Z; Tuerff, Sonya N

    2016-01-01

    Introduction In symptomatic subclavian steal syndrome, endovascular treatment is the first line of therapy prior to extra-anatomic surgical bypass procedures. Subintimal recanalization has been well described in the literature for the coronary arteries, and more recently, in the lower extremities. By modifying this approach, we present a unique retrograde technique using a heavy tip microwire to perform controlled subintimal dissection. Methods We present two cases of symptomatic subclavian steal related to chronic total occlusion of the left subclavian artery and right innominate artery, respectively. Standard crossing techniques were unsuccessful. Commonly at this point, the procedures would be aborted and open surgical intervention would have to be pursued. In our cases, retrograde access was easily achieved via an ipsilateral retrograde radial artery, using controlled subintimal dissection and a heavy-tipped wire. Results We were able to easily achieve recanalization in both attempted cases of chronic total occlusion of the subclavian and innominate artery, using a retrograde radial subintimal approach. Subsequent stent-supported angioplasty resulted in complete revascularization. No major complications were encountered during the procedures; however, one patient did develop thromboembolic stroke secondary to platelet aggregation to the stent graft, 9 days post-procedure. Conclusions Endovascular treatment is considered the first-line intervention in medically refractory patients with symptomatic subclavian steal syndrome. In the setting of chronic total occlusions, a retrograde radial subintimal approach using a heavy tip wire for controlled subintimal dissection is a novel technique that may be considered when standard approaches and wires have failed. PMID:26861024

  13. A Novel Percutaneous Electrode Implant for Improving Robustness in Advanced Myoelectric Control

    PubMed Central

    Hahne, Janne M.; Farina, Dario; Jiang, Ning; Liebetanz, David

    2016-01-01

    Despite several decades of research, electrically powered hand and arm prostheses are still controlled with very simple algorithms that process the surface electromyogram (EMG) of remnant muscles to achieve control of one prosthetic function at a time. More advanced machine learning methods have shown promising results under laboratory conditions. However, limited robustness has largely prevented the transfer of these laboratory advances to clinical applications. In this paper, we introduce a novel percutaneous EMG electrode to be implanted chronically with the aim of improving the reliability of EMG detection in myoelectric control. The proposed electrode requires a minimally invasive procedure for its implantation, similar to a cosmetic micro-dermal implant. Moreover, being percutaneous, it does not require power and data telemetry modules. Four of these electrodes were chronically implanted in the forearm of an able-bodied human volunteer for testing their characteristics. The implants showed significantly lower impedance and greater robustness against mechanical interference than traditional surface EMG electrodes used for myoelectric control. Moreover, the EMG signals detected by the proposed systems allowed more stable control performance across sessions in different days than that achieved with classic EMG electrodes. In conclusion, the proposed implants may be a promising interface for clinically available prostheses. PMID:27065783

  14. Nipple piercing may be contraindicated in male patients with chest implants.

    PubMed

    de Kleer, N; Cohen, M; Semple, J; Simor, A; Antonyshyn, O

    2001-08-01

    The authors present a man who underwent chest augmentation and nipple piercing. The patient developed chronic nipple infection, which led to unnecessary invasive diagnostic procedures, serious implant infection, and eventually urgent explantation. This unfavorable scenario illustrates the distinct features of the procedure in men, which includes close proximity of the nipple to the implant and reduced awareness by health care providers. Based on this case the authors recommend avoiding nipple piercing in men with chest implants.

  15. Pedicle screw loosening is correlated to chronic subclinical deep implant infection: a retrospective database analysis.

    PubMed

    Leitner, Lukas; Malaj, Isabella; Sadoghi, Patrick; Amerstorfer, Florian; Glehr, Mathias; Vander, Klaus; Leithner, Andreas; Radl, Roman

    2018-04-13

    Spinal fusion is used for treatment of spinal deformities, degeneration, infection, malignancy, and trauma. Reduction of motion enables osseous fusion and permanent stabilization of segments, compromised by loosening of the pedicle screws (PS). Deep implant infection, biomechanical, and chemical mechanisms are suspected reasons for loosening of PS. Study objective was to investigate the frequency and impact of deep implant infection on PS loosening. Intraoperative infection screening from wound and explanted material sonication was performed during revision surgeries following dorsal stabilization. Case history events and factors, which might promote implant infections, were included in this retrospective survey. 110 cases of spinal metal explantation were included. In 29.1% of revision cases, infection screening identified a germ, most commonly Staphylococcus (53.1%) and Propionibacterium (40.6%) genus. Patients screened positive had a significant higher number of previous spinal operations and radiologic loosening of screws. Patients revised for adjacent segment failure had a significantly lower rate of positive infection screening than patients revised for directly implant associated reasons. Removal of implants that revealed positive screening effected significant pain relief. Chronic implant infection seems to play a role in PS loosening and ongoing pain, causing revision surgery after spinal fusion. Screw loosening and multiple prior spinal operations should be suspicious for implant infection after spinal fusion when it comes to revision surgery. These slides can be retrieved under Electronic Supplementary Material.

  16. Immediate implants placed into infected sockets: a case report with 3-year follow-up.

    PubMed

    Naves, Marina de Melo; Horbylon, Bruna Zacharias; Gomes, Camila de Freitas; Menezes, Helder Henrique Machado de; Bataglion, César; Magalhães, Denildo de

    2009-01-01

    The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.

  17. Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports.

    PubMed

    Aryasit, Orapan; Ng, Danny S; Goh, Alice S C; Woo, Kyung In; Kim, Yoon-Duck

    2016-07-07

    Porous polyethylene implants are commonly used in orbital blowout fracture repair because of purported biocompatibility, durability, and low frequency of complications. Delayed inflammation related to porous polyethylene sheet implants is very rare and no case series of this condition have been reported. This is a retrospective review of clinical presentations, radiographic findings, histopathological findings, treatments, and outcomes of patients who developed delayed complications in orbital blowout fracture repair using porous polyethylene sheets. Four male patients were included with a mean age of 49 years (range 35-69 years). Blowout fracture repair was complicated with implant-related inflammation 10 months, 2 years, 3 years, and 8 years after surgery. Chronic and subacute orbital inflammatory signs were noted in two patients and acute fulminant orbital inflammation was found in two patients. Three patients developed peri-implant abscesses and one patient had a soft tissue mass around the implant. All patients underwent implant removal and two of these patients with paranasal sinusitis had sinus surgery. Histopathological findings revealed chronic inflammatory changes with fibrosis, and one patient had foreign body granuloma with culture positive Staphylococcus aureus. Delayed complications with porous polyethylene sheets used in orbital blowout fracture repair may occur many years following the initial surgery in immunocompetent patients. Low-grade or fulminant inflammation could complicate blowout fracture repair related with the implant.

  18. Optical coherence microscopy of mouse cortical vasculature surrounding implanted electrodes

    NASA Astrophysics Data System (ADS)

    Hammer, Daniel X.; Lozzi, Andrea; Abliz, Erkinay; Greenbaum, Noah; Turner, Kevin P.; Pfefer, T. Joshua; Agrawal, Anant; Krauthamer, Victor; Welle, Cristin G.

    2014-03-01

    Optical coherence microscopy (OCM) provides real-time, in-vivo, three-dimensional, isotropic micron-resolution structural and functional characterization of tissue, cells, and other biological targets. Optical coherence angiography (OCA) also provides visualization and quantification of vascular flow via speckle-based or phase-resolved techniques. Performance assessment of neuroprosthetic systems, which allow direct thought control of limb prostheses, may be aided by OCA. In particular, there is a need to examine the underlying mechanisms of chronic functional degradation of implanted electrodes. Angiogenesis, capillary network remodeling, and changes in flow velocity are potential indicators of tissue changes that may be associated with waning electrode performance. The overall goal of this investigation is to quantify longitudinal changes in vascular morphology and capillary flow around neural electrodes chronically implanted in mice. We built a 1315-nm OCM system to image vessels in neocortical tissue in a cohort of mice. An optical window was implanted on the skull over the primary motor cortex above a penetrating shank-style microelectrode array. The mice were imaged bi-weekly to generate vascular maps of the region surrounding the implanted microelectrode array. Acute effects of window and electrode implantation included vessel dilation and profusion of vessels in the superficial layer of the cortex (0-200 μm). In deeper layers surrounding the electrode, no qualitative differences were seen in this early phase. These measurements establish a baseline vascular tissue response from the cortical window preparation and lay the ground work for future longitudinal studies to test the hypothesis that vascular changes will be associated with chronic electrode degradation.

  19. Treatment-Limiting Complications of Percutaneous Spinal Cord Stimulator Implants: A Review of Eight Years of Experience From an Academic Center Database.

    PubMed

    Hayek, Salim M; Veizi, Elias; Hanes, Michael

    2015-10-01

    The study aims to evaluate the long-term implant survival and complications of spinal cord stimulation (SCS) leading to surgical revision or explant in patients treated for chronic noncancer pain. This is a retrospective study of all patients who underwent a percutaneous spinal cord stimulation trial followed by implant in an academic Pain Medicine division by four practitioners from 2007 to 2013, with follow-up data through April 2014. A total of 345 patients were considered candidates for dorsal column stimulation and underwent a trial. Two hundred thirty-four patients were implanted with an implant-to-trial ratio of 67-86% across various chronic pain entities (postlaminectomy syndrome, complex regional pain syndrome, small-fiber peripheral neuropathy, abdominal/pelvic pain, nonsurgical candidates with lumbosacral neuropathy, and neuropathic pain not otherwise specified), with the exception of nonsurgical candidates with lumbosacral neuropathy who had an implant ratio of 43%. The complication rate was 34.6%, with the hardware related being the most common reason, comprising 74.1% of all complications. The revision and explant rates were 23.9% each. The most common reason for explant was loss of therapeutic effect (41.1%). SCS is an effective treatment for chronic noncancer pain. It is a minimally invasive procedure, safe, and with good long-term outcomes. However, the surgical revision and explant rates are relatively high. As the use of SCS continues to grow, research into the causes of and risk factors for SCS-related complications is paramount to decrease complication rates in the future. © 2015 International Neuromodulation Society.

  20. Anisotropic Thermoelectric Devices Made from Single-Crystal Semimetal Microwires in Glass Coating

    NASA Astrophysics Data System (ADS)

    Konopko, L. A.; Nikolaeva, A. A.; Kobylianskaya, A. K.; Huber, T. E.

    2018-06-01

    Thermoelectric heat conversion based on the Seebeck and Peltier effects generated at the junction between two materials of type- n and type- p is well known. Here, we present a demonstration of an unconventional thermoelectric energy conversion that is based on a single element made of an anisotropic material. In such materials, a heat flow generates a transverse thermoelectric electric field lying across the heat flow. Potentially, in applications involving miniature devices, the anisotropic thermoelectric (AT) effect has the advantage over traditional thermoelectrics that it simplifies the thermoelectric generator architecture. This is because the generator can be made of a single thermoelectric material without the complexity of a series of contacts forming a pile. A feature of anisotropic thermoelectrics is that the thermoelectric voltage is proportional to the element length and inversely proportional to the effective thickness. The AT effect has been demonstrated with artificial anisotropic thin film consisting of layers of alternating thermoelectric type, but there has been no demonstration of this effect in a long single-crystal. Electronic transport measurements have shown that the semimetal bismuth is highly anisotropic. We have prepared an experimental sample consisting of a 10-m-long glass-insulated single-crystal tin-doped bismuth microwire ( d = 4 μm). Crucial for this experiment is the ability to grow the microwire as a single-crystal using a technique of recrystallization with laser heating and under a strong electric field. The sample was wound as a spiral, bonded to a copper disk, and used in various experiments. The sensitivity of the sample to heat flow is as high as 10-2 V/W with a time constant τ of about 0.5 s.

  1. Controlling depinning and propagation of single domain-walls in magnetic microwires

    NASA Astrophysics Data System (ADS)

    Jiménez, Alejandro; del Real, Rafael P.; Vázquez, Manuel

    2013-03-01

    The magnetization reversal in magnetostrictive amorphous microwires takes place by depinning and propagation of a single domain wall. This is a consequence of the particular domain structure determined by the strong uniaxial anisotropy from the reinforcement of magnetoelastic and shape contributions. In the present study, after an overview on the current state-of-the art on the topic, we introduce the general behaviour of single walls in 30 to 40 cm long Fe-base microwires propagating under homogeneous field. Depending on the way the walls are generated, we distinguish among three different walls namely, standard wall, DWst, depinned and propagating from the wire's end under homogeneous field which motion is the first one to switch on; reverse wall, DWrev, propagating from the opposite end under non-homogeneous field, and defect wall, DWdef, nucleated around local defect. Both, DWrev and DWdef are observed only under large enough applied field. In the subsequent section, we study the propagation of a wall under applied field smaller than the switching field. There, we conclude that a minimum field, Hdep,0, is needed to depin the DWst, as well as that a minimum field, Hprop,0, is required for the wall to propagate long distances. In the last section, we analyse the shape of induced signals in the pickup coils upon the crossing of the walls and its correlation to the domain walls shape. We conclude that length and shape of the wall are significantly distorted by the fact that the wall is typically as long as the measuring coils. Contribution to the Topical Issue "New Trends in Magnetism and Magnetic Materials", edited by Francesca Casoli, Massimo Solzi and Paola Tiberto.

  2. Anisotropic Thermoelectric Devices Made from Single-Crystal Semimetal Microwires in Glass Coating

    NASA Astrophysics Data System (ADS)

    Konopko, L. A.; Nikolaeva, A. A.; Kobylianskaya, A. K.; Huber, T. E.

    2018-04-01

    Thermoelectric heat conversion based on the Seebeck and Peltier effects generated at the junction between two materials of type-n and type-p is well known. Here, we present a demonstration of an unconventional thermoelectric energy conversion that is based on a single element made of an anisotropic material. In such materials, a heat flow generates a transverse thermoelectric electric field lying across the heat flow. Potentially, in applications involving miniature devices, the anisotropic thermoelectric (AT) effect has the advantage over traditional thermoelectrics that it simplifies the thermoelectric generator architecture. This is because the generator can be made of a single thermoelectric material without the complexity of a series of contacts forming a pile. A feature of anisotropic thermoelectrics is that the thermoelectric voltage is proportional to the element length and inversely proportional to the effective thickness. The AT effect has been demonstrated with artificial anisotropic thin film consisting of layers of alternating thermoelectric type, but there has been no demonstration of this effect in a long single-crystal. Electronic transport measurements have shown that the semimetal bismuth is highly anisotropic. We have prepared an experimental sample consisting of a 10-m-long glass-insulated single-crystal tin-doped bismuth microwire (d = 4 μm). Crucial for this experiment is the ability to grow the microwire as a single-crystal using a technique of recrystallization with laser heating and under a strong electric field. The sample was wound as a spiral, bonded to a copper disk, and used in various experiments. The sensitivity of the sample to heat flow is as high as 10-2 V/W with a time constant τ of about 0.5 s.

  3. Spatiotemporal characterization of brain infarction by sequential multimodal MR imaging following transient focal ischemia in a Rat model of intra-arterial middle cerebral artery occlusion.

    PubMed

    Gory, Benjamin; Chauveau, Fabien; Bolbos, Radu; Langlois, Jean-Baptiste; Labeyrie, Paul-Emile; Signorelli, Francesco; Turjman, Alexis; Turjman, Francis

    2016-12-01

    To assess spatiotemporal brain infarction evolution by sequential multimodal magnetic resonance (MR) imaging in an endovascular model of acute stroke in rats. A microwire was selectively placed in the middle cerebral artery (MCA) in 16 consecutives rats during 90 minutes occlusion. Longitudinal 7-T MR imaging, including angiography, diffusion, and perfusion was performed during ischemia, immediately after reperfusion, 3 h and 24 h after subsequent reperfusion. MCA occlusion was complete in 75 % and partial in 18.7 %. Hypoperfusion (mean ± SD) was observed in all animals during ischemia (-59 ± 18 % of contralateral hemisphere, area 31 ± 5 mm 2 ). Infarction volume (mean ± SD) was 90 ± 64 mm 3 during ischemia and 57 ± 67 mm 3 at 24 h. Brain infarction was fronto-parietal cortical in five animals (31 %), striatal in four animals (25 %), and cortico-striatal in seven animals (44 %) at 24 h. All rats survived at 24 h. This model is suitable to neuroprotection studies because of possible acute and close characterization of spatiotemporal evolution of brain infarction by MR imaging techniques, and evidence of ischemic penumbra, the target of neuroprotection agents. However, optimization of the brain infarct reproducibility needs further technical and neurointerventional tools improvements. • Nitinol microwire is MRI compatible allowing spatiotemporal characterization of brain infarction in rats. • Microwire selective placement in middle cerebral artery allows complete artery occlusion in 75 %. • A diffusion/perfusion mismatch during arterial occlusion is observed in 77 % of rats.

  4. Biocompatibility tests of components of an implantable cardiac assist device.

    PubMed

    von Recum, A F; Imamura, H; Freed, P S; Kantrowitz, A; Chen, S T; Ekstrom, M E; Baechler, C A; Barnhart, M I

    1978-09-01

    A permanently implantable in-series left ventricular assist device, the dynamic aortic patch (DAP), has been tested in chronic animal experiments. The DAP replaces a section of the intrathoracic aortic wall. Hemothorax and hematocele at the implantation site have been complications in recent experiments. Primary postoperative hemorrhage was ruled out, and the biocompatibility of all components was therefore examined. Dacron velour, Teflon felt, conductive polyurethane, segmented polyether polyurethane, and Teflon-coated polyester fiber sutures were implanted in the pleural cavities of dogs and tested in vitro by culturing canine saphenous vein explants on them. In vivo experiments demonstrated that all components elicited mild to moderate inflammatory reactions, but hematocele occurred only when the components were implanted in the aorta with direct blood contact and exposed to arterial blood pressures. In vitro, cells were cultured on all components with no signs of toxic reactions. These results indicated that the host tolerated all implant components without major inflammatory responses. However, histological data indicated that chronic slow bleeding into or through the Dacron velour in contact with the arterial blood serum could account for hemothorax or hematocele formation. Therefore, a configuration of the assist device using materials impermeable to blood may obviate these difficulties.

  5. Novel biological strategies for treatment of wear particle-induced periprosthetic osteolysis of orthopaedic implants for joint replacement

    PubMed Central

    Goodman, S. B.; Gibon, E.; Pajarinen, J.; Lin, T.-H.; Keeney, M.; Ren, P.-G.; Nich, C.; Yao, Z.; Egashira, K.; Yang, F.; Konttinen, Y. T.

    2014-01-01

    Wear particles and by-products from joint replacements and other orthopaedic implants may result in a local chronic inflammatory and foreign body reaction. This may lead to persistent synovitis resulting in joint pain and swelling, periprosthetic osteolysis, implant loosening and pathologic fracture. Strategies to modulate the adverse effects of wear debris may improve the function and longevity of joint replacements and other orthopaedic implants, potentially delaying or avoiding complex revision surgical procedures. Three novel biological strategies to mitigate the chronic inflammatory reaction to orthopaedic wear particles are reported. These include (i) interference with systemic macrophage trafficking to the local implant site, (ii) modulation of macrophages from an M1 (pro-inflammatory) to an M2 (anti-inflammatory, pro-tissue healing) phenotype in the periprosthetic tissues, and (iii) local inhibition of the transcription factor nuclear factor kappa B (NF-κB) by delivery of an NF-κB decoy oligodeoxynucleotide, thereby interfering with the production of pro-inflammatory mediators. These three approaches have been shown to be viable strategies for mitigating the undesirable effects of wear particles in preclinical studies. Targeted local delivery of specific biologics may potentially extend the lifetime of orthopaedic implants. PMID:24478281

  6. Implantation of the Medtronic Harmony Transcatheter Pulmonary Valve Improves Right Ventricular Size and Function in an Ovine Model of Postoperative Chronic Pulmonary Insufficiency.

    PubMed

    Schoonbeek, Rosanne C; Takebayashi, Satoshi; Aoki, Chikashi; Shimaoka, Toru; Harris, Matthew A; Fu, Gregory L; Kim, Timothy S; Dori, Yoav; McGarvey, Jeremy; Litt, Harold; Bouma, Wobbe; Zsido, Gerald; Glatz, Andrew C; Rome, Jonathan J; Gorman, Robert C; Gorman, Joseph H; Gillespie, Matthew J

    2016-10-01

    Pulmonary insufficiency is the nexus of late morbidity and mortality after transannular patch repair of tetralogy of Fallot. This study aimed to establish the feasibility of implantation of the novel Medtronic Harmony transcatheter pulmonary valve (hTPV) and to assess its effect on pulmonary insufficiency and ventricular function in an ovine model of chronic postoperative pulmonary insufficiency. Thirteen sheep underwent baseline cardiac magnetic resonance imaging, surgical pulmonary valvectomy, and transannular patch repair. One month after transannular patch repair, the hTPV was implanted, followed by serial magnetic resonance imaging and computed tomography imaging at 1, 5, and 8 month(s). hTPV implantation was successful in 11 animals (85%). There were 2 procedural deaths related to ventricular fibrillation. Seven animals survived the entire follow-up protocol, 5 with functioning hTPV devices. Two animals had occlusion of hTPV with aneurysm of main pulmonary artery. A strong decline in pulmonary regurgitant fraction was observed after hTPV implantation (40.5% versus 8.3%; P=0.011). Right ventricular end diastolic volume increased by 49.4% after transannular patch repair (62.3-93.1 mL/m 2 ; P=0.028) but was reversed to baseline values after hTPV implantation (to 65.1 mL/m 2 at 8 months, P=0.045). Both right ventricular ejection fraction and left ventricular ejection fraction were preserved after hTPV implantation. hTPV implantation is feasible, significantly reduces pulmonary regurgitant fraction, facilitates right ventricular volume improvements, and preserves biventricular function in an ovine model of chronic pulmonary insufficiency. This percutaneous strategy could potentially offer an alternative for standard surgical pulmonary valve replacement in dilated right ventricular outflow tracts, permitting lower risk, nonsurgical pulmonary valve replacement in previously prohibitive anatomies. © 2016 American Heart Association, Inc.

  7. Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates

    NASA Astrophysics Data System (ADS)

    Barrese, James C.; Aceros, Juan; Donoghue, John P.

    2016-04-01

    Objective. Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. Approach. We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. Main results. SEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. Significance. These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does not prevent useful recordings for several years. Progressive meningeal fibrosis encapsulates and lifts MEAs out of the cortex while ongoing foreign body reactions lead to progressive degradation of the materials. Long-term impedance drops are due to the corrosion of platinum, cracking and delamination of parylene, and delamination of silicone elastomer. Oxygen radicals released by cells of the immune system likely mediate the degradation of these materials. Future MEA designs must address these problems through more durable insulation materials, more inert electrode alloys, and pharmacologic suppression of fibroblasts and leukocytes.

  8. Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates

    PubMed Central

    Barrese, James C; Aceros, Juan; Donoghue, John P

    2016-01-01

    Objective Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. Approach We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. Main results SEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. Significance These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does not prevent useful recordings for several years. Progressive meningeal fibrosis encapsulates and lifts MEAs out of the cortex while ongoing foreign body reactions lead to progressive degradation of the materials. Long-term impedance drops are due to the corrosion of platinum, cracking and delamination of parylene, and delamination of silicone elastomer. Oxygen radicals released by cells of the immune system likely mediate the degradation of these materials. Future MEA designs must address these problems through more durable insulation materials, more inert electrode alloys, and pharmacologic suppression of fibroblasts and leukocytes. PMID:26824680

  9. Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates.

    PubMed

    Barrese, James C; Aceros, Juan; Donoghue, John P

    2016-04-01

    Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. SEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does not prevent useful recordings for several years. Progressive meningeal fibrosis encapsulates and lifts MEAs out of the cortex while ongoing foreign body reactions lead to progressive degradation of the materials. Long-term impedance drops are due to the corrosion of platinum, cracking and delamination of parylene, and delamination of silicone elastomer. Oxygen radicals released by cells of the immune system likely mediate the degradation of these materials. Future MEA designs must address these problems through more durable insulation materials, more inert electrode alloys, and pharmacologic suppression of fibroblasts and leukocytes.

  10. Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tommasini, R.; Bailey, C.; Bradley, D. K.

    High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV,more » of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.« less

  11. Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Tommasini, R.; Bailey, C.; Bradley, D. K.; Bowers, M.; Chen, H.; Di Nicola, J. M.; Di Nicola, P.; Gururangan, G.; Hall, G. N.; Hardy, C. M.; Hargrove, D.; Hermann, M.; Hohenberger, M.; Holder, J. P.; Hsing, W.; Izumi, N.; Kalantar, D.; Khan, S.; Kroll, J.; Landen, O. L.; Lawson, J.; Martinez, D.; Masters, N.; Nafziger, J. R.; Nagel, S. R.; Nikroo, A.; Okui, J.; Palmer, D.; Sigurdsson, R.; Vonhof, S.; Wallace, R. J.; Zobrist, T.

    2017-05-01

    High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV, of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.

  12. Growth and Brilliant Photo-Emission of Crystalline Hexagonal Column of Alq3 Microwires

    PubMed Central

    Kim, Seokho; Kim, Do Hyoung; Choi, Jinho; Lee, Hojin; Kim, Sun-Young; Park, Jung Woon; Park, Dong Hyuk

    2018-01-01

    We report the growth and nanoscale luminescence characteristics of 8-hydroxyquinolinato aluminum (Alq3) with a crystalline hexagonal column morphology. Pristine Alq3 nanoparticles (NPs) were prepared using a conventional reprecipitation method. Crystal hexagonal columns of Alq3 were grown by using a surfactant-assisted self-assembly technique as an adjunct to the aforementioned reprecipitation method. The formation and structural properties of the crystalline and non-crystalline Alq3 NPs were analyzed with scanning electron microscopy and X-ray diffraction. The nanoscale photoluminescence (PL) characteristics and the luminescence color of the Alq3 single NPs and their crystal microwires (MWs) were evaluated from color charge-coupled device images acquired using a high-resolution laser confocal microscope. In comparison with the Alq3 NPs, the crystalline MWs exhibited a very bright and sharp emission. This enhanced and sharp emission from the crystalline Alq3 single MWs originated from effective π-π stacking of the Alq3 molecules due to strong interactions in the crystalline structure. PMID:29565306

  13. Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

    DOE PAGES

    Tommasini, R.; Bailey, C.; Bradley, D. K.; ...

    2017-05-09

    High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV,more » of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.« less

  14. Flexible Light Emission Diode Arrays Made of Transferred Si Microwires-ZnO Nanofilm with Piezo-Phototronic Effect Enhanced Lighting.

    PubMed

    Li, Xiaoyi; Liang, Renrong; Tao, Juan; Peng, Zhengchun; Xu, Qiming; Han, Xun; Wang, Xiandi; Wang, Chunfeng; Zhu, Jing; Pan, Caofeng; Wang, Zhong Lin

    2017-04-25

    Due to the fragility and the poor optoelectronic performances of Si, it is challenging and exciting to fabricate the Si-based flexible light-emitting diode (LED) array devices. Here, a flexible LED array device made of Si microwires-ZnO nanofilm, with the advantages of flexibility, stability, lightweight, and energy savings, is fabricated and can be used as a strain sensor to demonstrate the two-dimensional pressure distribution. Based on piezo-phototronic effect, the intensity of the flexible LED array can be increased more than 3 times (under 60 MPa compressive strains). Additionally, the device is stable and energy saving. The flexible device can still work well after 1000 bending cycles or 6 months placed in the atmosphere, and the power supplied to the flexible LED array is only 8% of the power of the surface-contact LED. The promising Si-based flexible device has wide range application and may revolutionize the technologies of flexible screens, touchpad technology, and smart skin.

  15. Characterization of core/shell structures based on CdTe and GaAs nanocrystalline layers deposited on SnO2 microwires

    NASA Astrophysics Data System (ADS)

    Ghimpu, L.; Ursaki, V. V.; Pantazi, A.; Mesterca, R.; Brâncoveanu, O.; Shree, Sindu; Adelung, R.; Tiginyanu, I. M.; Enachescu, M.

    2018-04-01

    We report the fabrication and characterization of SnO2/CdTe and SnO2/GaAs core/shell microstructures. CdTe or GaAs shell layers were deposited by radio-frequency (RF) magnetron sputtering on core SnO2 microwires synthesized by a flame-based thermal oxidation method. The produced structures were characterized by scanning electron microscopy (SEM), high-resolution scanning transmission electron microscope (HR-STEM), X-ray diffraction (XRD), Raman scattering and FTIR spectroscopy. It was found that the SnO2 core is of the rutile type, while the shells are composed of CdTe or GaAs nanocrystallites of zincblende structure with the dimensions of crystallites in the range of 10-20 nm. The Raman scattering investigations demonstrated that the quality of the porous nanostructured shell is improved by annealing at temperatures of 420-450 °C. The prospects of implementing these microstructures in intrinsic type fiber optic sensors are discussed.

  16. 10 kHz High-Frequency Spinal Cord Stimulation for Chronic Axial Low Back Pain in Patients With No History of Spinal Surgery: A Preliminary, Prospective, Open Label and Proof-of-Concept Study.

    PubMed

    Al-Kaisy, Adnan; Palmisani, Stefano; Smith, Thomas E; Pang, David; Lam, Khai; Burgoyne, William; Houghton, Russell; Hudson, Emma; Lucas, Jonathan

    2017-01-01

    To explore the effectiveness of 10 kHz high frequency spinal cord stimulation (HF10 therapy) treatment of chronic low back pain in patients who have not had spinal surgery. Patients with chronic low back pain without prior spinal surgery were evaluated by a team of spine surgeons to rule out any spinal pathology amenable to surgical interventions and by a multidisciplinary pain team to confirm eligibility for the study. After a successful (>50% back pain reduction) trial of HF10 therapy, enrolled subjects underwent permanent system implantation and were followed-up one year post-implant. About 95% of the enrolled subjects (20/21) received the permanent system. At 12 months post-implant, both back pain VAS score and ODI were significantly reduced compared with baseline values (by 73% and 48%, respectively); an estimated quality-adjusted life year gain of 0.47 and a reduction in opioid use by 64% was observed. Four more patients among those unable to work at baseline due to back pain were employed at 12 months post-implant. There were no serious adverse events. HF10 therapy may provide significant back pain relief, reduction in disability, improvement quality of life, and reduction in opioid use in chronic low back pain not resulting from spinal surgery. © 2016 The Authors. Neuromodulation: Technology at the Neural Interface published by Wiley Periodicals, Inc. on behalf of International Neuromodulation Society.

  17. Effects of a sustained-release naloxone pellet on luteinizing hormone secretion in female rats.

    PubMed

    Gabriel, S M; Simpkins, J W

    1983-11-01

    Studies were undertaken to develop a naloxone implant capable of chronically blocking opioid receptors for several weeks in an effort to evaluate the effect of this prolonged narcotic antagonism on luteinizing hormone (LH) secretion in female rats. Antagonism of opiate receptors was achieved with a tablet formulation which contained 75 mg naloxone free base and a high content of the insoluble binding material, Mg stearate. Subcutaneous placement of this implant prevented morphine-induced analgesia for 2 weeks and antagonized the LH suppressory effects of morphine (15 or 30 mg/kg) administration. Thus, this naloxone delivery system is capable of chronically occupying the opioid receptors which mediate morphine's effects on analgesia and LH secretion. Despite this, the naloxone pellet only moderately enhanced the initial rate of increase in LH secretion following ovariectomy (day 1) and was ineffective in further augmenting LH secretion at 3 and 7 days after implantation. In rats which were ovariectomized and implanted immediately with estradiol-containing Silastic capsules, the naloxone pellet was ineffective in altering LH secretion 1, 3 or 7 days later. Thus, while chronic exposure to naloxone persistently antagonizes the pharmacologic actions of morphine, the naloxone pellet only transiently blocked the tonic inhibitory effect of endogenous opioid peptides. The mechanism by which the LH secretory effects of naloxone are lost following chronic exposure to the antagonist are at present unknown, but may involve the activation of compensatory mechanisms which are inhibitory to LH secretion.

  18. Chronic In Vivo Stability Assessment of Carbon Fiber Microelectrode Arrays

    PubMed Central

    Patel, Paras R.; Zhang, Huanan; Robbins, Matthew T.; Nofar, Justin B.; Marshall, Shaun P.; Kobylarek, Michael J.; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Chestek, Cynthia A.

    2016-01-01

    Objective Individual carbon fiber microelectrodes can record unit activity in both acute and semi-chronic (∼1 month) implants. Additionally, new methods have been developed to insert a 16 channel array of carbon fiber microelectrodes. Before assessing the in vivo long-term viability of these arrays, accelerated soak tests were carried out to determine the most stable site coating material. Next, a multi-animal, multi-month, chronic implantation study was carried out with carbon fiber microelectrode arrays and silicon electrodes. Approach Carbon fibers were first functionalized with one of two different formulations of PEDOT and subjected to accelerated aging in a heated water bath. After determining the best PEDOT formula to use, carbon fiber arrays were chronically implanted in rat motor cortex. Some rodents were also implanted with a single silicon electrode, while others received both. At the end of the study a subset of animals were perfused and the brain tissue sliced. Tissue sections were stained for astrocytes, microglia, and neurons. The local reactive responses were assessed using qualitative and quantitative methods. Main results Electrophysiology recordings showed the carbon fibers detecting unit activity for at least 3 months with average amplitudes of ∼200 μV. Histology analysis showed the carbon fiber arrays with a minimal to non-existent glial scarring response with no adverse effects on neuronal density. Silicon electrodes showed large glial scarring that impacted neuronal counts. Significance This study has validated the use of carbon fiber microelectrode arrays as a chronic neural recording technology. These electrodes have demonstrated the ability to detect single units with high amplitude over 3 months, and show the potential to record for even longer periods. In addition, the minimal reactive response should hold stable indefinitely, as any response by the immune system may reach a steady state after 12 weeks. PMID:27705958

  19. Chronic in vivo stability assessment of carbon fiber microelectrode arrays

    NASA Astrophysics Data System (ADS)

    Patel, Paras R.; Zhang, Huanan; Robbins, Matthew T.; Nofar, Justin B.; Marshall, Shaun P.; Kobylarek, Michael J.; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Chestek, Cynthia A.

    2016-12-01

    Objective. Individual carbon fiber microelectrodes can record unit activity in both acute and semi-chronic (∼1 month) implants. Additionally, new methods have been developed to insert a 16 channel array of carbon fiber microelectrodes. Before assessing the in vivo long-term viability of these arrays, accelerated soak tests were carried out to determine the most stable site coating material. Next, a multi-animal, multi-month, chronic implantation study was carried out with carbon fiber microelectrode arrays and silicon electrodes. Approach. Carbon fibers were first functionalized with one of two different formulations of PEDOT and subjected to accelerated aging in a heated water bath. After determining the best PEDOT formula to use, carbon fiber arrays were chronically implanted in rat motor cortex. Some rodents were also implanted with a single silicon electrode, while others received both. At the end of the study a subset of animals were perfused and the brain tissue sliced. Tissue sections were stained for astrocytes, microglia, and neurons. The local reactive responses were assessed using qualitative and quantitative methods. Main results. Electrophysiology recordings showed the carbon fibers detecting unit activity for at least 3 months with average amplitudes of ∼200 μV. Histology analysis showed the carbon fiber arrays with a minimal to non-existent glial scarring response with no adverse effects on neuronal density. Silicon electrodes showed large glial scarring that impacted neuronal counts. Significance. This study has validated the use of carbon fiber microelectrode arrays as a chronic neural recording technology. These electrodes have demonstrated the ability to detect single units with high amplitude over 3 months, and show the potential to record for even longer periods. In addition, the minimal reactive response should hold stable indefinitely, as any response by the immune system may reach a steady state after 12 weeks.

  20. H irradiation effects on the GaAs-like Raman modes in GaAs1-xNx/GaAs1-xNx:H planar heterostructures

    NASA Astrophysics Data System (ADS)

    Giulotto, E.; Geddo, M.; Patrini, M.; Guizzetti, G.; Felici, M.; Capizzi, M.; Polimeni, A.; Martelli, F.; Rubini, S.

    2014-12-01

    The GaAs-like longitudinal optical phonon frequency in two hydrogenated GaAs1-xNx/GaAs1-xNx:H microwire heterostructures—with similar N concentration, but different H dose and implantation conditions—has been investigated by micro-Raman mapping. In the case of GaAs0.991N0.009 wires embedded in barriers where GaAs-like properties are recovered through H irradiation, the phonon frequency in the barriers undergoes a blue shift with respect to the wires. In GaAs0.992N0.008 wires embedded in less hydrogenated barriers, the phonon frequency exhibits an opposite behavior (red shift). Strain, disorder, phonon localization effects induced by H-irradiation on the GaAs-like phonon frequency are discussed and related to different types of N-H complexes formed in the hydrogenated barriers. It is shown that the red (blue) character of the frequency shift is related to the dominant N-2H (N-3H) type of complexes. Moreover, for specific experimental conditions, an all-optical determination of the uniaxial strain field is obtained. This may improve the design of recently presented devices that exploit the correlation between uniaxial stress and the degree of polarization of photoluminescence.

  1. Evaluation of dual-tip micromanometers during 21-day implantation in goats

    NASA Technical Reports Server (NTRS)

    Reister, C. A.; Koenig, S. C.; Schaub, J. D.; Ewert, D. L.; Swope, R. D.; Latham, R. D.; Fanton, J. W.; Convertino, V. A. (Principal Investigator)

    1998-01-01

    Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

  2. Chronic intracortical microstimulation (ICMS) of cat sensory cortex using the Utah Intracortical Electrode Array.

    PubMed

    Rousche, P J; Normann, R A

    1999-03-01

    In an effort to assess the safety and efficacy of focal intracortical microstimulation (ICMS) of cerebral cortex with an array of penetrating electrodes as might be applied to a neuroprosthetic device to aid the deaf or blind, we have chronically implanted three trained cats in primary auditory cortex with the 100-electrode Utah Intracortical Electrode Array (UIEA). Eleven of the 100 electrodes were hard-wired to a percutaneous connector for chronic access. Prior to implant, cats were trained to "lever-press" in response to pure tone auditory stimulation. After implant, this behavior was transferred to "lever-presses" in response to current injections via single electrodes of the implanted arrays. Psychometric function curves relating injected charge level to the probability of response were obtained for stimulation of 22 separate electrodes in the three implanted cats. The average threshold charge/phase required for electrical stimulus detection in each cat was, 8.5, 8.6, and 11.6 nC/phase respectively, with a maximum charge/phase of 26 nC/phase and a minimum of 1.5 nC/phase thresholds were tracked for varying time intervals, and seven electrodes from two cats were tracked for up to 100 days. Electrodes were stimulated for no more than a few minutes each day. Neural recordings taken from the same electrodes before and after multiple electrical stimulation sessions were very similar in signal/noise ratio and in the number of recordable units, suggesting that the range of electrical stimulation levels used did not damage neurons in the vicinity of the electrodes. Although a few early implants failed, we conclude that ICMS of cerebral cortex to evoke a behavioral response can be achieved with the penetrating UIEA. Further experiments in support of a sensory cortical prosthesis based on ICMS are warranted.

  3. Two-way communication for programming and measurement in a miniature implantable stimulator.

    PubMed

    Thil, M A; Gérard, B; Jarvis, J C; Delbeke, J

    2005-07-01

    Implantable stimulators are needed for chronic electrical stimulation of nerves and muscles in experimental studies. The device described exploits the versatility of current microcontrollers for stimulation and communication in a miniature implant. Their standard outputs can provide the required selectable constant-current sources. In this device, pre-programmed stimulation paradigms were selected by transcutaneous light pulses. The potential of a programmable integrated circuit (PIC) was thus exploited. Implantable devices must be biocompatible. A novel encapsulation method that require no specialised equipment and that used two classical encapsulants, silicone and Teflon was developed. It was tested for implantation periods of up to four weeks. A novel way to estimate electrode impedance in awake animals is also presented. It was thus possible to follow the evolution of the nerve-electrode interface and, if necessary, to adjust the stimulation parameters. In practice, the electrode voltage at the end of a known constant-current pulse was measured by the PIC. The binary coded value was then indicated to the user as a series of muscle twitches that represented the binary value of the impedance measurement. This neurostimulator has been successfully tested in vitro and in vivo. Thresholds and impedance values were chronically monitored following implantation of a self-sizing spiral cuff electrode. Impedance variations in the first weeks could reflect morphological changes usually observed after the implantation of such electrodes.

  4. The Impact of Two-Stage Subtotal Petrosectomy and Round Window Vibroplasty on Bone Conduction Thresholds.

    PubMed

    Prenzler, Nils Kristian; Gruber, Lennart; Lenarz, Thomas; Maier, Hannes; Schwab, Burkard

    2018-06-14

    To evaluate possible increases in bone conduction (BC) hearing thresholds in patients undergoing subtotal petrosectomy (SP) with fat obliteration and blind sac closure of the outer ear canal and subsequent round window vibroplasty. Between 1997 and 2013, 43 patients (45 ears) with combined hearing loss and recurrent chronic otitis or status post formation of a radical cavity underwent SP around 6 months prior to implantation of a Vibrant SoundbridgeTM. Pure tone audiograms (0.5, 1, 1.5, 2, 3, 4, and 6 kHz) prior to SP, after SP, prior to implantation, after implantation, and at first fitting around 5 weeks after implantation were collected and statistically analyzed. The comparison between BC thresholds before SP and at first fitting showed an overall decline during the two-step procedure between 2.8 and 6 dB that was significant (p < 0.05, Student t test) at 2, 3, 4, and 6 kHz. In some cases, SP is the only way to eradicate chronic otitis and to achieve a suitable environment for the implantation of active middle ear implants. The present data demonstrate a relatively small but significant decline in BC thresholds throughout the whole procedure. Knowledge of its extent is mandatory for a correct indication for later implantation of a Vibrant SoundbridgeTM. © 2018 S. Karger AG, Basel.

  5. Long term assessment of blood pressure transducer drift in rhesus monkeys chronically instrumented with telemetry implants.

    PubMed

    Regan, Hillary K; Lynch, Joseph J; Regan, Christopher P

    2009-01-01

    The accurate assessment of blood pressure is often a key component of preclinical cardiovascular disease/efficacy models and of screening models used to determine the effects of test agents on cardiovascular physiology. Of the many methods utilized in large animals, telemetry is becoming more widely used throughout preclinical testing, and non-human primates are playing an ever increasing role as a large animal model to evaluate the cardiovascular effect of novel test agents. Therefore, we sought to characterize pressure transducer drift of a telemetry implant in primates over an extended duration. We instrumented ten rhesus monkeys with a Konigsberg T27F implant and a chronic indwelling arterial catheter and cross calibrated the diastolic pressure recorded by the implant to the diastolic pressure that was simultaneously recorded through the arterial catheter using a calibrated external transducer/amplifier system. While all implanted pressure transducers experienced drift to some degree, magnitude of drift varied across animals (range of average drift 0.7-20.5 mmHg/month). Specifically, we found that all implants could be calibrated within the voltage range of the instrument up to 6 months after implantation despite the drift observed. Between 6 and 12 months, 3 of the 10 implants studied drifted outside the defined voltage range and were unusable, two more drifted off scale within 2 years, while the remainder remained within the operating voltage range. Given that pressure transducer drift was not consistent across implants or time, these data suggest careful assessment and quantitative correction for in vivo drift of telemetry blood pressure transducers implanted for extended duration should be considered.

  6. [Osteosynthesis-associated infections : Epidemiology, definition and diagnosis].

    PubMed

    Renz, N; Feihl, S; Dlaska, C E; Schütz, M A; Trampuz, A

    2017-06-01

    Osteosynthesis-associated infections occur in 1-5% after closed and in up to 30% after open fractures. There are three different descriptions of implant-associated infections after fracture fixation, which are crucial for the selection of the adequate treatment strategy; temporal appearance from the index surgery (early versus late), pathogenesis of the infection (exogenous, hematogenous and contiguous from an adjacent focus), duration of infection symptoms (acute versus chronic). Diagnosis of osteosynthesis-associated infection is challenging, as chronic low-grade infections often present only with unspecific and subtle clinical symptoms. History, clinical evaluation, imaging, histopathlogical and microbiological examination build the cornerstones of diagnostics in implant-associated infections. A new onset of rest pain, early loosening of the prosthesis or mechanically unexplained, nonunion should raise suspicion for infection and prompt further evaluation. Percutaneous sinus tracts, purulent wound secretion and skin erosions with visibility of the implant confirm the implant-associated infection. Elevated C‑reactive protein value in blood is a supportive argument for infection, but is neither sensitive nor specific for infection. Imaging plays a key role to detect nonunions, infectious callus, sequester, peri-implant osteolysis and extraosseous and intramedullary involvement. Through microbiological and histopathological examination of intraoperative tissue samples, as well as sonication of explanted implants the causative pathogen is identified in most cases.

  7. TOPICAL REVIEW: Microsystem technologies for implantable applications

    NASA Astrophysics Data System (ADS)

    Receveur, Rogier A. M.; Lindemans, Fred W.; de Rooij, Nicolaas F.

    2007-05-01

    Microsystem technologies (MST) have become the basis of a large industry. The advantages of MST compared to other technologies provide opportunities for application in implantable biomedical devices. This paper presents a general and broad literature review of MST for implantable applications focused on the technical domain. A classification scheme is introduced to order the examples, basic technological building blocks relevant for implantable applications are described and finally a case study on the role of microsystems for one clinical condition is presented. We observe that the microfabricated parts span a wide range for implantable applications in various clinical areas. There are 94 active and 67 commercial 'end items' out of a total of 142. End item refers to the total concept, of which the microsystem may only be a part. From the 105 active end items 18 (13% of total number of end items) are classified as products. From these 18 products, there are only two for chronic use. The number of active end items in clinical, animal and proto phase for chronic use is 17, 13 and 20, respectively. The average year of first publication of chronic end items that are still in the animal or clinical phase is 1994 (n = 7) and 1993 (n = 11), respectively. The major technology market combinations are sensors for cardiovascular, drug delivery for drug delivery and electrodes for neurology and ophthalmology. Together these form 51% of all end items. Pressure sensors form the majority of sensors and there is just one product (considered to be an implantable microsystem) in the neurological area. Micro-machined ceramic packages, glass sealed packages and polymer encapsulations are used. Glass to metal seals are used for feedthroughs. Interconnection techniques such as flip chip, wirebonding or conductive epoxy as used in the semiconductor packaging and assembly industry are also used for manufacturing of implantable devices. Coatings are polymers or metal. As an alternative to implantable primary batteries, rechargeable batteries were introduced or concepts in which energy is provided from the outside based on inductive coupling. Long-term developments aiming at autonomous power are, for example, based on electrostatic conversion of mechanical vibrations. Communication with the implantable device is usually done using an inductive link. A large range of materials commonly used in microfabrication are also used for implantable microsystems.

  8. Direct and Quantitative Photothermal Absorption Spectroscopy of Individual Particulates

    DTIC Science & Technology

    2013-01-01

    1(a). By taking the ratio of the spectral absorption efficiency of the microwire to the corresponding volumetri - cally equivalent thin film, an...of D¼ 983 nm. For further comparison, the theoretical spectral absorption efficiency for a volumetri - cally equivalent (t¼ 983p/4 nm) thin film, Qabs

  9. Reliability of VEP Recordings Using Chronically Implanted Screw Electrodes in Mice

    PubMed Central

    Makowiecki, Kalina; Garrett, Andrew; Clark, Vince; Graham, Stuart L.; Rodger, Jennifer

    2015-01-01

    Purpose: Visual evoked potentials (VEPs) are widely used to objectively assess visual system function in animal models of ophthalmological diseases. Although use of chronically implanted electrodes is common in longitudinal VEP studies using rodent models, reliability of recordings over time has not been assessed. We compared VEPs 1 and 7 days after electrode implantation in the adult mouse. We also examined stimulus-independent changes over time, by assessing electroencephalogram (EEG) power and approximate entropy of the EEG signal. Methods: Stainless steel screws (600-μm diameter) were implanted into the skull overlying the right visual cortex and the orbitofrontal cortex of adult mice (C57Bl/6J, n = 7). Animals were reanesthetized 1 and 7 days after implantation to record VEP responses (flashed gratings) and EEG activity. Brain sections were stained for glial activation (GFAP) and cell death (TUNEL). Results: Reliability analysis, using intraclass correlation coefficients, showed VEP recordings had high reliability within the same session, regardless of time after electrode implantation and peak latencies and approximate entropy of the EEG did not change significantly with time. However, there was poorer reliability between recordings obtained on different days, and a significant decrease in VEP amplitudes and EEG power. This amplitude decrease could be normalized by scaling to EEG power (within-subjects). Furthermore, glial activation was present at both time points but there was no evidence of cell death. Conclusions: These results indicate that VEP responses can be reliably recorded even after a relatively short recovery period but decrease response peak amplitude over time. Although scaling the VEP trace to EEG power normalized this decrease, our results highlight that time-dependent cortical excitability changes are an important consideration in longitudinal VEP studies. Translational Relevance: This study shows changes in VEP characteristics over time in chronically implanted mice. Thus, future preclinical longitudinal studies should consider time in addition to amplitude and latency when designing and interpreting research. PMID:25938003

  10. Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cord

    NASA Astrophysics Data System (ADS)

    Ersen, Ali; Elkabes, Stella; Freedman, David S.; Sahin, Mesut

    2015-02-01

    Objective. Microelectrodes implanted in the central nervous system (CNS) often fail in long term implants due to the immunological tissue response caused by tethering forces of the connecting wires. In addition to the tethering effect, there is a mechanical stress that occurs at the device-tissue interface simply because the microelectrode is a rigid body floating in soft tissue and it cannot reshape itself to comply with changes in the surrounding tissue. In the current study we evaluated the scar tissue formation to tetherless devices with two significantly different geometries in the rat brain and spinal cord in order to investigate the effects of device geometry. Approach. One of the implant geometries resembled the wireless, floating microstimulators that we are currently developing in our laboratory and the other was a (shank only) Michigan probe for comparison. Both electrodes were implanted into either the cervical spinal cord or the motor cortices, one on each side. Main results. The most pronounced astroglial and microglial reactions occurred within 20 μm from the device and decreased sharply at larger distances. Both cell types displayed the morphology of non-activated cells past the 100 μm perimeter. Even though the aspect ratios of the implants were different, the astroglial and microglial responses to both microelectrode types were very mild in the brain, stronger and yet limited in the spinal cord. Significance. These observations confirm previous reports and further suggest that tethering may be responsible for most of the tissue response in chronic implants and that the electrode size has a smaller contribution with floating electrodes. The electrode size may be playing primarily an amplifying role to the tethering forces in the brain whereas the size itself may induce chronic response in the spinal cord where the movement of surrounding tissues is more significant.

  11. Moderate hypothermia technique for chronic implantation of a total artificial heart in calves.

    PubMed

    Karimov, Jamshid H; Grady, Patrick; Sinkewich, Martin; Sunagawa, Gengo; Dessoffy, Raymond; Byram, Nicole; Moazami, Nader; Fukamachi, Kiyotaka

    2017-06-01

    The benefit of whole-body hypothermia in preventing ischemic injury during cardiac surgical operations is well documented. However, application of hypothermia during in vivo total artificial heart implantation has not become widespread because of limited understanding of the proper techniques and restrictions implied by constitutional and physiological characteristics specific to each animal model. Similarly, the literature on hypothermic set-up in total artificial heart implantation has also been limited. Herein we present our experience using hypothermia in bovine models implanted with the Cleveland Clinic continuous-flow total artificial heart.

  12. A trabecular metal implant 4 months after placement: clinical-histologic case report.

    PubMed

    Spinato, Sergio; Zaffe, Davide; Felice, Pietro; Checchi, Luigi; Wang, Hom-Lay

    2014-02-01

    The aim of this case report was to histologically evaluate the behavior of a trabecular metal (TM) implant composed of titanium and spatial 3-dimensional tantalum (Ta) trabeculae. This study is the first human histologic case report of this implant. A TM implant was placed in a 54-year-old woman exhibiting moderate chronic periodontitis. After periodontal treatment, the implant was inserted under favorable clinical conditions. Patient was not seen for 4 months because of unrelated breast reduction surgery. At the surgical reopening, periimplant inflammation affecting the coronal third of the implant was observed 4 months after implant placement. With patient's consent, the implant was removed for histologic analysis. Histology highlighted a greater amount of bone in close contact with Ta trabeculae than titanium surfaces. The finding of bone formation around the Ta trabeculae suggests that trabecular metal material promotes bone ingrowth for secondary implant stability. Additional evidence is needed to confirm this observation.

  13. Retrospective comparative analysis of cardiovascular implantable electronic device infections with and without the use of antibacterial envelopes.

    PubMed

    Hassoun, A; Thottacherry, E D; Raja, M; Scully, M; Azarbal, A

    2017-03-01

    Cardiovascular implantable electronic device (CIED) infections are associated with morbidity and mortality. Peri-operative systemic intravenous antibiotic prophylaxis reduces the rate of CIED infections. AIGIS Rx , a polymer envelope implanted with the CIED, releases minocycline and rifampin, and has been introduced to reduce infections. Retrospective review of 184 patients who underwent CIED implantation was conducted. Ninety-two patients were implanted with an AIGIS Rx envelope (AIGIS Rx group) and 92 patients were not implanted with an AIGIS Rx envelope (control group). Data were collected on demographics and risk factors for CIED infections (i.e. congestive heart failure, renal insufficiency, chronic kidney disease, oral anticoagulant use, chronic steroid use, need for lead replacement or revision, temporary pacing, early re-intervention, and having more than two leads in place). Rates of implantation success, major infections and mortality were compared between the AIGIS Rx group and the control group. The AIGIS Rx group had longer hospitalizations (6.8±10.7 days vs 3.1±5.2 days; P=0.001), higher chronic corticosteroid use, higher rates of replacement or revision (51.1% vs 8.7%; P=0.001), and a greater proportion of devices with more than two intracardiac leads (42.4% vs 29.3%; P=0.03) than the control group. Successful implantation occurred in 97% of patients in both groups. Major infection was seen in 5.4% of cases in the AIGIS Rx group and 1.1% of cases in the control group (P=0.048). Device removal was conducted in 3.3% of cases in the AIGIS Rx group compared with 1.1% of cases in the control group (P=0.16). There were two deaths in the AIGIS Rx group. Organisms cultured were meticillin-resistant Staphylococcus aureus, meticillin-susceptible S. aureus and Enterococcus faecalis. The AIGIS Rx group had higher rates of major infection but also higher risk factors compared with the control group. The rate of device extraction and CIED-related mortality was higher in the AIGIS Rx group than in the control group. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. Intravitreal bevacizumab and dexamethasone implant for treatment of chronic diabetic macular edema.

    PubMed

    Güler, Emre; Totan, Yüksel; Betül Güragaç, Fatma

    2017-06-01

    To evaluate anatomical and functional outcomes of intraviteal bevacizumab (IVB) in patients with chronic diabetic macular edema (DME), and the effectivity and safety of dexamethasone implant in those unresponsive to regular IVB treatment. Thirty-five eyes of 35 patients (16 male and 19 female) with chronic DME (central foveal thickness (CFT)  > 275 μm, duration  > 6 months) received three injections of 2.5 mg IVB with six-week intervals. At 18 weeks, dexamethasone implant was applied to patients unresponsive to IVB. Main outcomes were the change in best corrected visual acuity (BCVA), CFT and ocular and systemic adverse effects for both drugs. The patients responsive to IVB were followed up for 36 weeks and those patients receiving dexamethasone implant were followed up for 24 weeks postoperatively. At 18 weeks, the mean BCVA (0.68 ± 0.40 logMAR, p = 0.45) and CFT (453 ± 169 μm, p = 0.58) did not show any significant change compared to baseline (0.74 ± 0.42 logMAR and 521 ± 151 μm, respectively). In 20 patients (%57.1) responsive to IVB, the CFT was significantly improved from 12 to 36 weeks with the mean value of 295 ± 42 μ (p = 0.01). However, no significant difference was observed for BCVA during this period (p = 0.17). Dexamethasone was implanted in 15 eyes (42.8%) unresponsive to IVB at 18 weeks. Statistically significant improvements were observed in BCVA (at postoperative 4 and 12 weeks) and CFT (at postoperative 4, 12 and 24 weeks). In addition, both parameters significantly worsened at 24 weeks compared to 12 weeks (p < 0.001 and p = 0.01, respectively). Patients with chronic DME should be followed in accordance with a fixed treatment protocol combining anti-VEGF and steroid treatments.

  15. Chronic implantation of cuff electrodes on the pelvic nerve in rats is well tolerated and does not compromise afferent or efferent fibre functionality

    NASA Astrophysics Data System (ADS)

    Crook, J. J.; Brouillard, C. B. J.; Irazoqui, P. P.; Lovick, T. A.

    2018-04-01

    Objective. Neuromodulation of autonomic nerve activity to regulate physiological processes is an emerging field. Vagal stimulation has received most attention whereas the potential of modulate visceral function by targeting autonomic nerves within the abdominal cavity remains under-exploited. Surgery to locate intra-abdominal targets is inherently more stressful than for peripheral nerves. Electrode leads risk becoming entrapped by intestines and loss of functionality in the nerve-target organ connection could result from electrode migration or twisting. Since nociceptor afferents are intermingled with similar-sized visceral autonomic fibres, stimulation may induce pain. In anaesthetised rats high frequency stimulation of the pelvic nerve can suppress urinary voiding but it is not known how conscious animals would react to this procedure. Our objective therefore was to determine how rats tolerated chronic implantation of cuff electrodes on the pelvic nerve, whether nerve stimulation would be aversive and whether nerve-bladder functionality would be compromised. Approach. We carried out a preliminary de-risking study to investigate how conscious rats tolerated chronic implantation of electrodes on the pelvic nerve, their responsiveness to intermittent high frequency stimulation and whether functionality of the nerve-bladder connection became compromised. Main results. Implantation of cuff electrodes was well-tolerated. The normal diurnal pattern of urinary voiding was not disrupted. Pelvic nerve stimulation (up to 4 mA, 3 kHz) for 30 min periods evoked mild alerting at stimulus onset but no signs of pain. Stimulation evoked a modest (<0.5 °C) increase in nerve temperature but the functional integrity of the nerve-bladder connection, reflected by contraction of the detrusor muscle in response to 10 Hz nerve stimulation, was not compromised. Significance. Chronic implantation of cuff electrodes on the pelvic nerve was found to be a well-tolerated procedure in rats and high frequency stimulation did not lead to loss of nerve functionality. Pelvic nerve stimulation has development potential for normalizing voiding dysfunction in conscious rats.

  16. HISTOLOGICAL STUDIES OF THE EFFECTS OF CHRONIC IMPLANTATION OF CERAMIC-BASED MICROELECTRODE ARRAYS AND MICRODIALYSIS PROBES IN RAT PREFRONTAL CORTEX

    PubMed Central

    Hascup, Erin R.; Bjerkén, Sara af; Hascup, Kevin N.; Pomerleau, Francois; Huettl, Peter; Strömberg, Ingrid; Gerhardt, Greg A.

    2010-01-01

    Chronic implantation of neurotransmitter measuring devices is essential for awake, behavioral studies occurring over multiple days. Little is known regarding the effects of long term implantation on surrounding brain parenchyma and the resulting alterations in the functional properties of this tissue. We examined the extent of tissue damage produced by chronic implantation of either ceramic microelectrode arrays (MEAs) or microdialysis probes. Histological studies were carried out on fixed tissues using stains for neurons (cresyl violet), astrocytes (GFAP), microglia (Iba-1), glutamatergic nerve fibers (VGLUT1), and the blood-brain barrier (SMI-71). Nissl staining showed pronounced tissue body loss with microdialysis implants compared to MEAs. The MEAs produced mild gliosis extending 50–100 µm from the tracks, with a significant change in the affected areas starting at 3 days. By contrast, the microdialysis probes produced gliosis extending 200–300 µm from the track, which was significant at 3 and 7 days. Markers for microglia and glutamatergic fibers supported that the MEAs produce minimal damage with significant changes occurring only at 3 and 7 days that return to control levels by one month. SMI-71 staining supported integrity of the blood brain barrier out to 1 week for both the microdialysis probes and the MEAs. This data support that the ceramic MEAs small size and biocompatibility are necessary to accurately measure neurotransmitter levels in the intact brain. The minimal invasiveness of the MEAs reduce tissue loss, allowing for long term (>6 month) electrochemical and electrophysiological monitoring of brain activity. PMID:19577548

  17. A residual granuloma in association with a dental implant.

    PubMed

    McCracken, Michael S; Chavali, Ramakiran V; Al-Naief, Nasser Said; Eleazer, Paul D

    2012-04-01

    At times, dental implants are placed into sites with a history of periapical pathology. Sometimes the infection is active, and other times the tooth may have been extracted years before implant placement. In either case, the possibility exists for long-term residual cysts or infections that can negatively impact the prognosis of the implant. In this case report, an implant is placed into a healed mandibular ridge several months after extraction of the tooth. A radiolucency was noted on routine radiographic examination 2 years later. Surgical inspection and histology revealed a periapical granuloma with acute and chronic inflammatory cells. After surgical curettage of the site, the patient healed without complication. Implants may develop apical pathology as a result of a preexisting long-term residual infection.

  18. A fully implantable pacemaker for the mouse: from battery to wireless power.

    PubMed

    Laughner, Jacob I; Marrus, Scott B; Zellmer, Erik R; Weinheimer, Carla J; MacEwan, Matthew R; Cui, Sophia X; Nerbonne, Jeanne M; Efimov, Igor R

    2013-01-01

    Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice.

  19. Chronic sinusitis associated with the use of unrecognized bone substitute: a case report.

    PubMed

    Beklen, Arzu; Pihakari, Antti; Rautemaa, Riina; Hietanen, Jarkko; Ali, Ahmed; Konttinen, Yrjö T

    2008-05-01

    Bone grafts are used for bone augmentation to ensure optimal implant placement. However, this procedure may sometimes cause sinusitis. The case of a 44-year-old woman with the diagnosis of recurrent and chronic sinusitis of her right maxillary sinus with a history of dental implant surgery is presented. After several attempts with normal standard sinusitis therapy, unrecognized bone substitute was removed from the sinus cavity, which finally led to resolution of the sinusitis. This case reiterates the importance of a careful examination, consultation, and second opinion for the selection of optimal treatment.

  20. Knee and Ankle Arthroplasty in Hemophilia

    PubMed Central

    Solimeno, Luigi Piero; Pasta, Gianluigi

    2017-01-01

    Today, major surgical procedures can be safely performed in hemophilic patients with chronic arthropathy, using available factor concentrates. In this setting, total knee replacement is considered the “gold standard”, while the use of total ankle replacement is still debated. Indeed, the unsatisfactory results obtained with the previous available design of implants did not raise enthusiasm as knee or hip replacement. Recently, the introduction of new implant designs and better reported outcomes have renewed the interest in total ankle replacement in people with hemophilia. In this review, the role of replacement surgery in the treatment of chronic hemophilic arthropathy will be described. PMID:29165342

  1. Optical Coherence Tomography and Stent Boost Imaging Guided Bioresorbable Vascular Scaffold Overlapping for Coronary Chronic Total Occlusion Lesion

    PubMed Central

    Li, Hu; Choi, Cheol Ung; Oh, Dong Joo

    2017-01-01

    We report herein the optical coherence tomography (OCT) and stent boost imaging guided bioresorbable vascular scaffold (BVS) implantation for right coronary artery (RCA) chronic total occlusion (CTO) lesion. The gold standard for evaluating BVS expansion after percutaneous coronary intervention is OCT. However, stent boost imaging is a new technique that improves fluoroscopy-based assessments of stent overlapping, and the present case shows clinical usefulness of OCT and stent boost imaging guided ‘overlapping’ BVS implantation via antegrade approach for a typical RCA CTO lesion. PMID:28792157

  2. Brain plasticity after implanted peroneal nerve electrical stimulation to improve gait in chronic stroke patients: Two case reports.

    PubMed

    Thibaut, Aurore; Moissenet, Florent; Di Perri, Carol; Schreiber, Céline; Remacle, Angélique; Kolanowski, Elisabeth; Chantraine, Frédéric; Bernard, Claire; Hustinx, Roland; Tshibanda, Jean-Flory; Filipetti, Paul; Laureys, Steven; Gosseries, Olivia

    2017-01-01

    Recent studies have shown that stimulation of the peroneal nerve using an implantable 4-channel peroneal nerve stimulator could improve gait in stroke patients. To assess structural cortical and regional cerebral metabolism changes associated with an implanted peroneal nerve electrical stimulator to correct foot drop related to a central nervous system lesion. Two stroke patients presenting a foot drop related to a central nervous system lesion were implanted with an implanted peroneal nerve electrical stimulator. Both patients underwent clinical evaluations before implantation and one year after the activation of the stimulator. Structural magnetic resonance imaging (MRI) and [18F]-fluorodeoxyglucose-positron emission tomography (FDG-PET) were acquired before and one year after the activation of the stimulator. Foot drop was corrected for both patients after the implantation of the stimulator. After one year of treatment, patient 1 improved in three major clinical tests, while patient 2 only improved in one test. Prior to treatment, FDG-PET showed a significant hypometabolism in premotor, primary and supplementary motor areas in both patients as compared to controls, with patient 2 presenting more widespread hypometabolism. One year after the activation of the stimulator, both patients showed significantly less hypometabolism in the damaged motor cortex. No difference was observed on the structural MRI. Clinical improvement of gait under peroneal nerve electrical stimulation in chronic stroke patients presenting foot drop was paralleled to metabolic changes in the damaged motor cortex.

  3. Oral Rehabilitation of a Severe Periodontally Involved Patient with Mucous Membrane Pemphigoid: A 15-Year Follow-Up Case Report.

    PubMed

    Megarbane, Jean-Marie; Freiha, Cécile; Mokbel, Nadim

    Mucous membrane pemphigoid (MMP) refers to a group of chronic autoimmune subepithelial diseases distinguished by erosive lesions of the mucous membranes and skin. Its treatment consists of inhibition of the inflammatory reaction by means of corticosteroids and symptomatic medication. This is a report of a patient suffering from a combination of MMP and severe generalized chronic periodontitis. The patient has been treated with oral corticosteroids, initial phase therapy, extraction with immediate implant placement, and periodontal surgery where the prognosis was questionable. The case has been followed up for 15 years. Periodontal therapy with immediate implant placement was determined to be a viable modality to achieve a total rehabilitation of a case suffering from MMP combined with severe generalized chronic periodontitis.

  4. A Simple and Low-Cost Ultramicroelectrode Fabrication and Characterization Method for Undergraduate Students

    ERIC Educational Resources Information Center

    Sur, Ujjal Kumar; Dhason, A.; Lakshminarayanan, V.

    2012-01-01

    A laboratory experiment is described in which students fabricate disk-shaped gold and platinum microelectrodes with diameters of 10-50 [mu]m by sealing sodalime glass with metal microwires. The electrodes are characterized by performing cyclic voltammetry in aqueous and acetonitrile solution. Commercial microelectrodes are expensive (cost depends…

  5. Mesoscale modeling of photoelectrochemical devices: light absorption and carrier collection in monolithic, tandem, Si|WO3 microwires.

    PubMed

    Fountaine, Katherine T; Atwater, Harry A

    2014-10-20

    We analyze mesoscale light absorption and carrier collection in a tandem junction photoelectrochemical device using electromagnetic simulations. The tandem device consists of silicon (E(g,Si) = 1.1 eV) and tungsten oxide (E(g,WO3) = 2.6 eV) as photocathode and photoanode materials, respectively. Specifically, we investigated Si microwires with lengths of 100 µm, and diameters of 2 µm, with a 7 µm pitch, covered vertically with 50 µm of WO3 with a thickness of 1 µm. Many geometrical variants of this prototypical tandem device were explored. For conditions of illumination with the AM 1.5G spectra, the nominal design resulted in a short circuit current density, J(SC), of 1 mA/cm(2), which is limited by the WO3 absorption. Geometrical optimization of photoanode and photocathode shape and contact material selection, enabled a three-fold increase in short circuit current density relative to the initial design via enhanced WO3 light absorption. These findings validate the usefulness of a mesoscale analysis for ascertaining optimum optoelectronic performance in photoelectrochemical devices.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Huadan; Yin, Xukun; Zhang, Guofeng

    Quartz-enhanced conductance spectroscopy is developed as an analytical tool to investigate dynamic nanomechanical behaviors of polymer wires, in order to determine the glass transition temperature (T{sub g}). A polymethyl methacrylate (PMMA) microwire with a diameter of 10 μm was bridged across the prongs of a quartz tuning fork (QTF). With the advantage of QTF self-sensing as compared with micro-cantilevers or other resonators, the resonance frequency and Q factor can be directly determined by means of its electrical conductance spectra with respect to the frequency of the external excitation source (dI/dV vs f), and therefore, no optical beam is required. The T{submore » g} of the PMMA microwire was determined by the maximum loss modulus of the QTF, calculated from the resonance frequency and the Q factor as a function of temperature. The measured T{sub g} of the PMMA is 103 °C with an error of ±2 °C. Both heating/cooling and physical aging experiments were carried out, demonstrating that the technique is both reversible and reproducible.« less

  7. Simultaneously Enhancing Light Emission and Suppressing Efficiency Droop in GaN Microwire-Based Ultraviolet Light-Emitting Diode by the Piezo-Phototronic Effect.

    PubMed

    Wang, Xingfu; Peng, Wenbo; Yu, Ruomeng; Zou, Haiyang; Dai, Yejing; Zi, Yunlong; Wu, Changsheng; Li, Shuti; Wang, Zhong Lin

    2017-06-14

    Achievement of p-n homojuncted GaN enables the birth of III-nitride light emitters. Owing to the wurtzite-structure of GaN, piezoelectric polarization charges present at the interface can effectively control/tune the optoelectric behaviors of local charge-carriers (i.e., the piezo-phototronic effect). Here, we demonstrate the significantly enhanced light-output efficiency and suppressed efficiency droop in GaN microwire (MW)-based p-n junction ultraviolet light-emitting diode (UV LED) by the piezo-phototronic effect. By applying a -0.12% static compressive strain perpendicular to the p-n junction interface, the relative external quantum efficiency of the LED is enhanced by over 600%. Furthermore, efficiency droop is markedly reduced from 46.6% to 7.5% and corresponding droop onset current density shifts from 10 to 26.7 A cm -2 . Enhanced electrons confinement and improved holes injection efficiency by the piezo-phototronic effect are revealed and theoretically confirmed as the physical mechanisms. This study offers an unconventional path to develop high efficiency, strong brightness and high power III-nitride light sources.

  8. Evolution of Photoluminescence, Raman, and Structure of CH3NH3PbI3 Perovskite Microwires Under Humidity Exposure

    NASA Astrophysics Data System (ADS)

    Segovia, Rubén; Qu, Geyang; Peng, Miao; Sun, Xiudong; Shi, Hongyan; Gao, Bo

    2018-03-01

    Self-assembled organic-inorganic CH3NH3PbI3 perovskite microwires (MWs) upon humidity exposure along several weeks were investigated by photoluminescence (PL) spectroscopy, Raman spectroscopy, and X-ray diffraction (XRD). We show that, in addition to the common perovskite decomposition into PbI2 and the formation of a hydrated phase, humidity induced a gradual PL redshift at the initial weeks that is stabilized for longer exposure ( 21 nm over the degradation process) and an intensity enhancement. Original perovskite Raman band and XRD reflections slightly shifted upon humidity, indicating defects formation and structure distortion of the MWs crystal lattice. By correlating the PL, Raman, and XRD results, it is believed that the redshift of the MWs PL emission was originated from the structural disorder caused by the incorporation of H2O molecules in the crystal lattice and radiative recombination through moisture-induced subgap trap states. Our study provides insights into the optical and structural response of organic-inorganic perovskite materials upon humidity exposure.

  9. Multidisciplinary management including periodontics, orthodontics, implants, and prosthetics for an adult.

    PubMed

    Pinho, Teresa; Neves, Manuel; Alves, Célia

    2012-08-01

    This article describes the complex dental treatment of an adult patient with multiple missing teeth, mild chronic periodontitis, and a malocclusion with a cant of the occlusal plane. After periodontal treatment, titanium implants and a miniscrew were placed to correct the occlusal plane canting with orthodontic treatment. Prosthodontic treatment was completed by using osseointegrated implants to replace the missing teeth. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  10. Use of the Photo-Electromyogram to Objectively Diagnose and Monitor Treatment of Post-TBI Light Sensitivity

    DTIC Science & Technology

    2013-10-01

    Eye Clinic are being seen by the PI (Randy Kardon MD PhD) in his VA and University of Iowa neuro -ophthalmology clinics. These patients are being...using the DSI wireless data transmission system. We have implanted a functional transmitter into a subcutaneous pocket beyond the scapulae on the...implant more so than smaller mice. Figure 7. Recovery of mouse chronically implanted with subcutaneous EMG electrodes and transmitter . There was

  11. Regenerated Sciatic Nerve Axons Stimulated through a Chronically Implanted Macro-Sieve Electrode.

    PubMed

    MacEwan, Matthew R; Zellmer, Erik R; Wheeler, Jesse J; Burton, Harold; Moran, Daniel W

    2016-01-01

    Sieve electrodes provide a chronic interface for stimulating peripheral nerve axons. Yet, successful utilization requires robust axonal regeneration through the implanted electrode. The present study determined the effect of large transit zones in enhancing axonal regeneration and revealed an intimate neural interface with an implanted sieve electrode. Fabrication of the polyimide sieve electrodes employed sacrificial photolithography. The manufactured macro-sieve electrode (MSE) contained nine large transit zones with areas of ~0.285 mm 2 surrounded by eight Pt-Ir metallized electrode sites. Prior to implantation, saline, or glial derived neurotropic factor (GDNF) was injected into nerve guidance silicone-conduits with or without a MSE. The MSE assembly or a nerve guidance conduit was implanted between transected ends of the sciatic nerve in adult male Lewis rats. At 3 months post-operation, fiber counts were similar through both implant types. Likewise, stimulation of nerves regenerated through a MSE or an open silicone conduit evoked comparable muscle forces. These results showed that nerve regeneration was comparable through MSE transit zones and an open conduit. GDNF had a minimal positive effect on the quality and morphology of fibers regenerating through the MSE; thus, the MSE may reduce reliance on GDNF to augment axonal regeneration. Selective stimulation of several individual muscles was achieved through monopolar stimulation of individual electrodes sites suggesting that the MSE might be an optimal platform for functional neuromuscular stimulation.

  12. Enhanced biocompatibility of neural probes by integrating microstructures and delivering anti-inflammatory agents via microfluidic channels

    NASA Astrophysics Data System (ADS)

    Liu, Bin; Kim, Eric; Meggo, Anika; Gandhi, Sachin; Luo, Hao; Kallakuri, Srinivas; Xu, Yong; Zhang, Jinsheng

    2017-04-01

    Objective. Biocompatibility is a major issue for chronic neural implants, involving inflammatory and wound healing responses of neurons and glial cells. To enhance biocompatibility, we developed silicon-parylene hybrid neural probes with open architecture electrodes, microfluidic channels and a reservoir for drug delivery to suppress tissue responses. Approach. We chronically implanted our neural probes in the rat auditory cortex and investigated (1) whether open architecture electrode reduces inflammatory reaction by measuring glial responses; and (2) whether delivery of antibiotic minocycline reduces inflammatory and tissue reaction. Four weeks after implantation, immunostaining for glial fibrillary acid protein (astrocyte marker) and ionizing calcium-binding adaptor molecule 1 (macrophages/microglia cell marker) were conducted to identify immunoreactive astrocyte and microglial cells, and to determine the extent of astrocytes and microglial cell reaction/activation. A comparison was made between using traditional solid-surface electrodes and newly-designed electrodes with open architecture, as well as between deliveries of minocycline and artificial cerebral-spinal fluid diffused through microfluidic channels. Main results. The new probes with integrated micro-structures induced minimal tissue reaction compared to traditional electrodes at 4 weeks after implantation. Microcycline delivered through integrated microfluidic channels reduced tissue response as indicated by decreased microglial reaction around the neural probes implanted. Significance. The new design will help enhance the long-term stability of the implantable devices.

  13. Long-term hearing result using Kurz titanium ossicular implants.

    PubMed

    Hess-Erga, Jeanette; Møller, Per; Vassbotn, Flemming Slinning

    2013-05-01

    Titanium implants in middle ear surgery were introduced in the late 90s and are now frequently used in middle ear surgery. However, long-term studies of patient outcome are few and have only been published in subgroups of patients. We report the long-term effect of titanium middle ear implants for ossicular reconstruction in chronic ear disease investigated in a Norwegian tertiary otological referral centre. Retrospective chart reviews were performed for procedures involving 76 titanium implants between 2000 and 2007. All patients who underwent surgery using the Kurz Vario titanium implant were included in the study. Audiological parameters using four frequencies, 0.5, 1, 2, and 3 kHz, according to AAO-HNS guidelines, was assessed pre and postoperatively. Otosurgical procedures, complications, revisions, and extrusion rates were analyzed. The study had no dropouts. The partial ossicular replacement prosthesis (PORP) was used in 44 procedures and the total ossicular replacement prosthesis (TORP) in 32 procedures, respectively. Mean follow-up was 5.2 years (62 months). The ossiculoplasties were performed as staging procedures or in combination with other chronic ear surgery. The same surgeon performed all the procedures. A postoperative air-bone gap of ≤ 20 dB was obtained in 74 % of the patients, 82 % for the Bell (PORP) prosthesis, and 63 % for the Arial (TORP) prosthesis. The extrusion rate was 5 %. We conclude that titanium ossicular implants give stable and excellent long-term hearing results.

  14. Regenerated Sciatic Nerve Axons Stimulated through a Chronically Implanted Macro-Sieve Electrode

    PubMed Central

    MacEwan, Matthew R.; Zellmer, Erik R.; Wheeler, Jesse J.; Burton, Harold; Moran, Daniel W.

    2016-01-01

    Sieve electrodes provide a chronic interface for stimulating peripheral nerve axons. Yet, successful utilization requires robust axonal regeneration through the implanted electrode. The present study determined the effect of large transit zones in enhancing axonal regeneration and revealed an intimate neural interface with an implanted sieve electrode. Fabrication of the polyimide sieve electrodes employed sacrificial photolithography. The manufactured macro-sieve electrode (MSE) contained nine large transit zones with areas of ~0.285 mm2 surrounded by eight Pt-Ir metallized electrode sites. Prior to implantation, saline, or glial derived neurotropic factor (GDNF) was injected into nerve guidance silicone-conduits with or without a MSE. The MSE assembly or a nerve guidance conduit was implanted between transected ends of the sciatic nerve in adult male Lewis rats. At 3 months post-operation, fiber counts were similar through both implant types. Likewise, stimulation of nerves regenerated through a MSE or an open silicone conduit evoked comparable muscle forces. These results showed that nerve regeneration was comparable through MSE transit zones and an open conduit. GDNF had a minimal positive effect on the quality and morphology of fibers regenerating through the MSE; thus, the MSE may reduce reliance on GDNF to augment axonal regeneration. Selective stimulation of several individual muscles was achieved through monopolar stimulation of individual electrodes sites suggesting that the MSE might be an optimal platform for functional neuromuscular stimulation. PMID:28008303

  15. The effects on bone cells of metal ions released from orthopaedic implants. A review

    PubMed Central

    Sansone, Valerio; Pagani, Davide; Melato, Marco

    2013-01-01

    Summary The increasing use of orthopedic implants and, in particular, of hip and knee joint replacements for young and active patients, has stimulated interest and concern regarding the chronic, long-term effects of the materials used. This review focuses on the current knowledge of the adverse biologic reactions to metal particles released from orthopaedic implants in vivo and in vitro. More specifically, the purpose of this article is to provide an overview of the current literature about the adverse effects of metal particles on bone cells and peri-implant bone. PMID:23858309

  16. Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording

    PubMed Central

    Weir, Richard F. ff.; Troyk, Phil R.; DeMichele, Glen A.; Kerns, Douglas A.; Schorsch, Jack F.; Maas, Huub

    2011-01-01

    We have developed a multichannel electrogmyography sensor system capable of receiving and processing signals from up to 32 implanted myoelectric sensors (IMES). The appeal of implanted sensors for myoelectric control is that electromyography (EMG) signals can be measured at their source providing relatively cross-talk-free signals that can be treated as independent control sites. An external telemetry controller receives telemetry sent over a transcutaneous magnetic link by the implanted electrodes. The same link provides power and commands to the implanted electrodes. Wireless telemetry of EMG signals from sensors implanted in the residual musculature eliminates the problems associated with percutaneous wires, such as infection, breakage, and marsupialization. Each implantable sensor consists of a custom-designed application-specified integrated circuit that is packaged into a bio-compatible RF BION capsule from the Alfred E. Mann Foundation. Implants are designed for permanent long-term implantation with no servicing requirements. We have a fully operational system. The system has been tested in animals. Implants have been chronically implanted in the legs of three cats and are still completely operational four months after implantation. PMID:19224729

  17. Peri-implant bony overgrowth as a cause of revision surgery in auditory osseointegrated implantation.

    PubMed

    Tompkins, Jared J; Petersen, Dana K; Sharbel, Daniel D; McKinnon, Brian J; MacDonald, C Bruce

    2016-07-01

    Implantation of auditory osseointegrated implants, also known as bone-anchored hearing systems (BAHS), represents a surgical option for select pediatric patients aged 5 years or older with hearing loss. Functional indications in this patient population include conductive or mixed hearing loss. Common complications of implantation include skin infections, chronic skin irritation, hypertrophic skin overgrowth, and loose abutments. In a case series of 15 pediatric patients, we discovered an unexpectedly high skin-related complication rate requiring surgical revision of 53%. During revision surgery, we discovered 5 patients who exhibited significant bony overgrowth at the abutment site, a complication infrequently noted in past literature. Published by Elsevier Ireland Ltd.

  18. Comparative analysis of histopathologic effects of synthetic meshes based on material, weight, and pore size in mice.

    PubMed

    Orenstein, Sean B; Saberski, Ean R; Kreutzer, Donald L; Novitsky, Yuri W

    2012-08-01

    While synthetic prosthetics have essentially become mandatory for hernia repair, mesh-induced chronic inflammation and scarring can lead to chronic pain and limited mobility. Mesh propensity to induce such adverse effects is likely related to the prosthetic's material, weight, and/or pore size. We aimed to compare histopathologic responses to various synthetic meshes after short- and long-term implantations in mice. Samples of macroporous polyester (Parietex [PX]), heavyweight microporous polypropylene (Trelex[TX]), midweight microporous polypropylene (ProLite[PL]), lightweight macroporous polypropylene (Ultrapro[UP]), and expanded polytetrafluoroethylene (DualMesh[DM]) were implanted subcutaneously in mice. Four and 12 wk post-implantation, meshes were assessed for inflammation, foreign body reaction (FBR), and fibrosis. All meshes induced varying levels of inflammatory responses. PX induced the greatest inflammatory response and marked FBR. DM induced moderate FBR and a strong fibrotic response with mesh encapsulation at 12 wk. UP and PL had the lowest FBR, however, UP induced a significant chronic inflammatory response. Although inflammation decreased slightly for TX, marked FBR was present throughout the study. Of the three polypropylene meshes, fibrosis was greatest for TX and slightly reduced for PL and UP. For UP and PL, there was limited fibrosis within each mesh pore. Polyester mesh induced the greatest FBR and lasting chronic inflammatory response. Likewise, marked fibrosis and encapsulation was seen surrounding ePTFE. Heavier polypropylene meshes displayed greater early and persistent fibrosis; the reduced-weight polypropylene meshes were associated with the least amount of fibrosis. Mesh pore size was inversely proportional to bridging fibrosis. Moreover, reduced-weight polypropylene meshes demonstrated the smallest FBR throughout the study. Overall, we demonstrated that macroporous, reduced-weight polypropylene mesh exhibited the highest degree of biocompatibility at sites of mesh implantation. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Combined Ahmed Glaucoma Valve Placement, Intravitreal Fluocinolone Acetonide Implantation and Cataract Extraction for Chronic Uveitis.

    PubMed

    Chang, Ingrid T; Gupta, Divakar; Slabaugh, Mark A; Vemulakonda, Gurunadh A; Chen, Philip P

    2016-10-01

    To report the outcomes of combined Ahmed glaucoma valve (AGV) placement, intravitreal fluocinolone acetonide implant, and cataract extraction procedure in the treatment of chronic noninfectious uveitis. Retrospective case series of patients with chronic noninfectious uveitis who underwent AGV placement, intravitreal fluocinolone acetonide implantation, and cataract extraction in a single surgical session performed at 1 institution from January 2009 to November 2014. Outcome measures included intraocular pressure (IOP) and glaucoma medication use. Secondary outcome measures included visual acuity, systemic anti-inflammatory medications, number of uveitis flares, and complications. Fifteen eyes of 10 patients were studied, with a mean age of 40.3±15.7 and mean follow-up duration of 26 months (range, 13 to 39 mo). Before surgery, the IOP was 18.5±7.3 mm Hg and patients were using 1.5±1.5 topical glaucoma medications. At the 12-month follow-up, IOP was 12.8±3.2 mm Hg (P=0.01) and patients were using 0.5±0.8 (P=0.03) topical glaucoma medications. At 36 months of follow-up, late, nonsustained hypotony had occurred in 3 eyes (20%), and 1 eye (6%) had received a second AGV for IOP control. Before treatment, patients had 2.7±1.5 uveitis flares in the year before surgery while on an average of 2.1±0.6 systemic anti-inflammatory medications, which decreased to an average of 0.1±0.3 (P<0.01) flares the year after surgery while on an average of 0.4±1.1 (P<0.01) systemic medications. Combined AGV, intravitreal fluocinolone acetonide implant, and cataract extraction is effective in controlling IOP and reducing the number of glaucoma medications at 12 months after treatment in patients with chronic uveitis.

  20. Continuous intraputamenal convection-enhanced delivery in adult rhesus macaques.

    PubMed

    Fan, Xiaotong; Nelson, Brian D; Ai, Yi; Stiles, David K; Gash, Don M; Hardy, Peter A; Zhang, Zhiming

    2015-12-01

    Assessing the safety and feasibility of chronic delivery of compounds to the brain using convection-enhanced delivery (CED) is important for the further development of this important therapeutic technology. The objective of this study was to follow and model the distribution of a compound delivered by CED into the putamen of rhesus monkeys. The authors sequentially implanted catheters into 4 sites spanning the left and right putamen in each of 6 rhesus monkeys. The catheters were connected to implanted pumps, which were programmed to deliver a 5-mM solution of the MRI contrast agent Gd-DTPA at 0.1 μl/minute for 7 days and 0.3 μl/minute for an additional 7 days. The animals were followed for 28 days per implant cycle during which they were periodically examined with MRI. All animals survived the 4 surgeries with no deficits in behavior. Compared with acute infusion, the volume of distribution (Vd) increased 2-fold with 7 days of chronic infusion. Increasing the flow rate 3-fold over the next week increased the Vd an additional 3-fold. Following withdrawal of the compound, the half-life of Gd-DTPA in the brain was estimated as 3.1 days based on first-order pharmacokinetics. Histological assessment of the brain showed minimal tissue damage limited to the insertion site. These results demonstrate several important features in the development of a chronically implanted pump and catheter system: 1) the ability to place catheters accurately in a predetermined target; 2) the ability to deliver compounds in a chronic fashion to the putamen; and 3) the use of MRI and MR visible tracers to follow the evolution of the infusion volume over time.

  1. Aircraft flight simulation of spacelab experiment using an implanted telemetry system to obtain cardiovascular data from the monkey

    NASA Technical Reports Server (NTRS)

    Mccutcheon, E. P.; Miranda, R.; Fryer, T. B.; Hodges, G.; Newson, B. D.; Pace, N.

    1977-01-01

    The utility of a multichannel implantable telemetry system for obtaining cardiovascular data was tested in a monkey with a CV-990 aircraft flight simulation of a space flight experiment. Valuable data were obtained to aid planning and execution of flight experiments using chronically instrumented animals.

  2. Wireless, Ultra-Low-Power Implantable Sensor for Chronic Bladder Pressure Monitoring.

    PubMed

    Majerus, Steve J A; Garverick, Steven L; Suster, Michael A; Fletter, Paul C; Damaser, Margot S

    2012-06-01

    The wireless implantable/intracavity micromanometer (WIMM) system was designed to fulfill the unmet need for a chronic bladder pressure sensing device in urological fields such as urodynamics for diagnosis and neuromodulation for bladder control. Neuromodulation in particular would benefit from a wireless bladder pressure sensor which could provide real-time pressure feedback to an implanted stimulator, resulting in greater bladder capacity while using less power. The WIMM uses custom integrated circuitry, a MEMS transducer, and a wireless antenna to transmit pressure telemetry at a rate of 10 Hz. Aggressive power management techniques yield an average current draw of 9 μ A from a 3.6-Volt micro-battery, which minimizes the implant size. Automatic pressure offset cancellation circuits maximize the sensing dynamic range to account for drifting pressure offset due to environmental factors, and a custom telemetry protocol allows transmission with minimum overhead. Wireless operation of the WIMM has demonstrated that the external receiver can receive the telemetry packets, and the low power consumption allows for at least 24 hours of operation with a 4-hour wireless recharge session.

  3. Wireless, Ultra-Low-Power Implantable Sensor for Chronic Bladder Pressure Monitoring

    PubMed Central

    MAJERUS, STEVE J. A.; GARVERICK, STEVEN L.; SUSTER, MICHAEL A.; FLETTER, PAUL C.; DAMASER, MARGOT S.

    2015-01-01

    The wireless implantable/intracavity micromanometer (WIMM) system was designed to fulfill the unmet need for a chronic bladder pressure sensing device in urological fields such as urodynamics for diagnosis and neuromodulation for bladder control. Neuromodulation in particular would benefit from a wireless bladder pressure sensor which could provide real-time pressure feedback to an implanted stimulator, resulting in greater bladder capacity while using less power. The WIMM uses custom integrated circuitry, a MEMS transducer, and a wireless antenna to transmit pressure telemetry at a rate of 10 Hz. Aggressive power management techniques yield an average current draw of 9 μA from a 3.6-Volt micro-battery, which minimizes the implant size. Automatic pressure offset cancellation circuits maximize the sensing dynamic range to account for drifting pressure offset due to environmental factors, and a custom telemetry protocol allows transmission with minimum overhead. Wireless operation of the WIMM has demonstrated that the external receiver can receive the telemetry packets, and the low power consumption allows for at least 24 hours of operation with a 4-hour wireless recharge session. PMID:26778926

  4. A Multimodal, SU-8 - Platinum - Polyimide Microelectrode Array for Chronic In Vivo Neurophysiology

    PubMed Central

    Márton, Gergely; Orbán, Gábor; Kiss, Marcell; Fiáth, Richárd; Pongrácz, Anita; Ulbert, István

    2015-01-01

    Utilization of polymers as insulator and bulk materials of microelectrode arrays (MEAs) makes the realization of flexible, biocompatible sensors possible, which are suitable for various neurophysiological experiments such as in vivo detection of local field potential changes on the surface of the neocortex or unit activities within the brain tissue. In this paper the microfabrication of a novel, all-flexible, polymer-based MEA is presented. The device consists of a three dimensional sensor configuration with an implantable depth electrode array and brain surface electrodes, allowing the recording of electrocorticographic (ECoG) signals with laminar ones, simultaneously. In vivo recordings were performed in anesthetized rat brain to test the functionality of the device under both acute and chronic conditions. The ECoG electrodes recorded slow-wave thalamocortical oscillations, while the implanted component provided high quality depth recordings. The implants remained viable for detecting action potentials of individual neurons for at least 15 weeks. PMID:26683306

  5. A Multimodal, SU-8 - Platinum - Polyimide Microelectrode Array for Chronic In Vivo Neurophysiology.

    PubMed

    Márton, Gergely; Orbán, Gábor; Kiss, Marcell; Fiáth, Richárd; Pongrácz, Anita; Ulbert, István

    2015-01-01

    Utilization of polymers as insulator and bulk materials of microelectrode arrays (MEAs) makes the realization of flexible, biocompatible sensors possible, which are suitable for various neurophysiological experiments such as in vivo detection of local field potential changes on the surface of the neocortex or unit activities within the brain tissue. In this paper the microfabrication of a novel, all-flexible, polymer-based MEA is presented. The device consists of a three dimensional sensor configuration with an implantable depth electrode array and brain surface electrodes, allowing the recording of electrocorticographic (ECoG) signals with laminar ones, simultaneously. In vivo recordings were performed in anesthetized rat brain to test the functionality of the device under both acute and chronic conditions. The ECoG electrodes recorded slow-wave thalamocortical oscillations, while the implanted component provided high quality depth recordings. The implants remained viable for detecting action potentials of individual neurons for at least 15 weeks.

  6. Supportive periodontal therapy and periodontal biotype as prognostic factors in implants placed in patients with a history of periodontitis.

    PubMed

    Aguirre-Zorzano, Luis-Antonio; Vallejo-Aisa, Francisco-Javier; Estefanía-Fresco, Ruth

    2013-09-01

    To evaluate bone loss around implants placed in patients with a history of treated chronic periodontitis and who did or did not attend supportive periodontal therapy, after one year in function. Furthermore, the influence of periodontal biotype and level of plaque was also evaluated. Forty-nine patients participated voluntarily in the study. All subjects had a history of chronic periodontitis, which had been previously treated. After the active treatment, 27 patients attended supportive periodontal therapy (SPT) and the rest did not (No SPT). The O'Leary plaque index and periodontal biotype were recorded for each subject and 246 Astra Tech® OsseospeedTM implants were radiographically analysed (123 placed in SPT patients and 123 in No SPT patients) at the time of loading and one year later, measuring marginal bone loss with the program Dental Studio NX 6.0®. The statistical analysis was performed with Windows SPSS, applying Pearson's correlation index and the Kruskal-Wallis and U-Mann Whitney non-parametric tests. Six patients were found to have periimplantitis and sixteen mucositis. The survival rate was 99.59% (100% SPT and 99.18% No SPT). Mean bone loss was 0.39 mm (range [-0.71 - 8.05]). Among SPT patients, 95% of the implants had losses less than or equal to the mean (mean bone loss of 0.16 mm) compared to 53.7% for the No SPT group (mean bone loss of 0.62 mm). A statistically significant relationship was demonstrated between bone loss around the implant and the patient's periodontal biotype and plaque index. The marginal bone loss around implants in patients with treated chronic periodontitis is minimal if they are in a controlled SPT programme and there is individual control of plaque index. Moreover, the presence of a thin periodontal biotype represents a risk factor for additional bone loss.

  7. A novel flexible cuff-like microelectrode for dual purpose, acute and chronic electrical interfacing with the mouse cervical vagus nerve

    NASA Astrophysics Data System (ADS)

    Caravaca, A. S.; Tsaava, T.; Goldman, L.; Silverman, H.; Riggott, G.; Chavan, S. S.; Bouton, C.; Tracey, K. J.; Desimone, R.; Boyden, E. S.; Sohal, H. S.; Olofsson, P. S.

    2017-12-01

    Objective. Neural reflexes regulate immune responses and homeostasis. Advances in bioelectronic medicine indicate that electrical stimulation of the vagus nerve can be used to treat inflammatory disease, yet the understanding of neural signals that regulate inflammation is incomplete. Current interfaces with the vagus nerve do not permit effective chronic stimulation or recording in mouse models, which is vital to studying the molecular and neurophysiological mechanisms that control inflammation homeostasis in health and disease. We developed an implantable, dual purpose, multi-channel, flexible ‘microelectrode’ array, for recording and stimulation of the mouse vagus nerve. Approach. The array was microfabricated on an 8 µm layer of highly biocompatible parylene configured with 16 sites. The microelectrode was evaluated by studying the recording and stimulation performance. Mice were chronically implanted with devices for up to 12 weeks. Main results. Using the microelectrode in vivo, high fidelity signals were recorded during physiological challenges (e.g potassium chloride and interleukin-1β), and electrical stimulation of the vagus nerve produced the expected significant reduction of blood levels of tumor necrosis factor (TNF) in endotoxemia. Inflammatory cell infiltration at the microelectrode 12 weeks of implantation was limited according to radial distribution analysis of inflammatory cells. Significance. This novel device provides an important step towards a viable chronic interface for cervical vagus nerve stimulation and recording in mice.

  8. Techniques for chronic monitoring of brain activity in freely moving sheep using wireless EEG recording.

    PubMed

    Perentos, N; Nicol, A U; Martins, A Q; Stewart, J E; Taylor, P; Morton, A J

    2017-03-01

    Large mammals with complex central nervous systems offer new possibilities for translational research into basic brain function. Techniques for monitoring brain activity in large mammals, however, are not as well developed as they are in rodents. We have developed a method for chronic monitoring of electroencephalographic (EEG) activity in unrestrained sheep. We describe the methods for behavioural training prior to implantation, surgical procedures for implantation, a protocol for reliable anaesthesia and recovery, methods for EEG data collection, as well as data pertaining to suitability and longevity of different types of electrodes. Sheep tolerated all procedures well, and surgical complications were minimal. Electrode types used included epidural and subdural screws, intracortical needles and subdural disk electrodes, with the latter producing the best and most reliable results. The implants yielded longitudinal EEG data of consistent quality for periods of at least a year, and in some cases up to 2 years. This is the first detailed methodology to be described for chronic brain function monitoring in freely moving unrestrained sheep. The developed method will be particularly useful in chronic investigations of brain activity during normal behaviour that can include sleep, learning and memory. As well, within the context of disease, the method can be used to monitor brain pathology or the progress of therapeutic trials in transgenic or natural disease models in sheep. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Peripheral nerve field stimulation for chronic neuropathic pain: a single institution experience.

    PubMed

    D'Ammando, A; Messina, G; Franzini, A; Dones, I

    2016-04-01

    Peripheral nerve field stimulation (PNFS) is a novel neurosurgical procedure consisting of implantation of subcutaneous leads in specific painful areas in different types of painful, drug-resistant syndromes. The objective of this study was to evaluate the efficacy of PNFS in several patients affected by different chronic neuropathic pain syndromes, along with its risks, limits and possible correlation between the results achieved and the patients' main symptoms. Twenty-two patients affected by different types of chronic neuropathic pain were submitted to PNFS at the Department of Neurosurgery of the Istituto Neurologico "C. Besta" in Milan between July 2009 and July 2013. The visual analog scale (VAS) and variations in the use of analgesic drugs, along with complications, were considered to assess results. In 59 % of our patients, an average pain reduction of 5.50 points on the visual analog scale was observed (average pre-implant score 8.86 and average post-implant score 3.36). These patients reduced their analgesic drug use after PNFS. We observed no early or long-term complications after our last follow-up evaluation. PNFS can be considered an effective and safe option to treat carefully selected, drug-resistant and chronic neuropathic pain patients; the reversibility of the procedure and its lack, at least in our hands, of long-term complications may contribute to wider use of this procedure.

  10. Cardiac Rotational Mechanics As a Predictor of Myocardial Recovery in Heart Failure Patients Undergoing Chronic Mechanical Circulatory Support: A Pilot Study.

    PubMed

    Bonios, Michael J; Koliopoulou, Antigone; Wever-Pinzon, Omar; Taleb, Iosif; Stehlik, Josef; Xu, Weining; Wever-Pinzon, James; Catino, Anna; Kfoury, Abdallah G; Horne, Benjamin D; Nativi-Nicolau, Jose; Adamopoulos, Stamatis N; Fang, James C; Selzman, Craig H; Bax, Jeroen J; Drakos, Stavros G

    2018-04-01

    Impaired qualitative and quantitative left ventricular (LV) rotational mechanics predict cardiac remodeling progression and prognosis after myocardial infarction. We investigated whether cardiac rotational mechanics can predict cardiac recovery in chronic advanced cardiomyopathy patients. Sixty-three patients with advanced and chronic dilated cardiomyopathy undergoing implantation of LV assist device (LVAD) were prospectively investigated using speckle tracking echocardiography. Acute heart failure patients were prospectively excluded. We evaluated LV rotational mechanics (apical and basal LV twist, LV torsion) and deformational mechanics (circumferential and longitudinal strain) before LVAD implantation. Cardiac recovery post-LVAD implantation was defined as (1) final resulting LV ejection fraction ≥40%, (2) relative LV ejection fraction increase ≥50%, (iii) relative LV end-systolic volume decrease ≥50% (all 3 required). Twelve patients fulfilled the criteria for cardiac recovery (Rec Group). The Rec Group had significantly less impaired pre-LVAD peak LV torsion compared with the Non-Rec Group. Notably, both groups had similarly reduced pre-LVAD LV ejection fraction. By receiver operating characteristic curve analysis, pre-LVAD peak LV torsion of 0.35 degrees/cm had a 92% sensitivity and a 73% specificity in predicting cardiac recovery. Peak LV torsion before LVAD implantation was found to be an independent predictor of cardiac recovery after LVAD implantation (odds ratio, 0.65 per 0.1 degrees/cm [0.49-0.87]; P =0.014). LV rotational mechanics seem to be useful in selecting patients prone to cardiac recovery after mechanical unloading induced by LVADs. Future studies should investigate the utility of these markers in predicting durable cardiac recovery after the explantation of the cardiac assist device. © 2018 American Heart Association, Inc.

  11. Suppression of scarring in peripheral nerve implants by drug elution.

    PubMed

    FitzGerald, James J

    2016-04-01

    Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progressive decline in signal level because the scar tissue gradually separates axons away from the recording contacts. In regenerative sieves and microchannel electrodes, progressive scar deposition will constrict and may eventually choke off the sieve hole or channel lumen. Interface designs need to address this issue if they are to be fit for long term use. This study examines a novel method of inhibiting the formation and thickening of the fibrous scar. Research to date has mainly focused on methods of preventing stimulation of the foreign body response by implant surface modification. In this paper a pharmacological approach using drug elution to suppress chronic inflammation is introduced. Microchannel implants made of silicone doped with the steroid drug dexamethasone were implanted in the rat sciatic nerve for periods of up to a year. Tissue from within the microchannels was compared to that from control devices that did not release any drug. In the drug eluting implants the scar layer was significantly thinner at all timepoints, and unlike the controls it did not continue to thicken after 6 months. Control implants supported axon regeneration well initially, but axon counts fell rapidly at later timepoints as scar thickened. Axon counts in drug eluting devices were initially much lower, but increased rather than declined and by one year were significantly higher than in controls. Drug elution offers a potential long term solution to the problem of performance degradation due to scarring around neural implants.

  12. Suppression of scarring in peripheral nerve implants by drug elution

    NASA Astrophysics Data System (ADS)

    FitzGerald, James J.

    2016-04-01

    Objective. Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progressive decline in signal level because the scar tissue gradually separates axons away from the recording contacts. In regenerative sieves and microchannel electrodes, progressive scar deposition will constrict and may eventually choke off the sieve hole or channel lumen. Interface designs need to address this issue if they are to be fit for long term use. This study examines a novel method of inhibiting the formation and thickening of the fibrous scar. Approach. Research to date has mainly focused on methods of preventing stimulation of the foreign body response by implant surface modification. In this paper a pharmacological approach using drug elution to suppress chronic inflammation is introduced. Microchannel implants made of silicone doped with the steroid drug dexamethasone were implanted in the rat sciatic nerve for periods of up to a year. Tissue from within the microchannels was compared to that from control devices that did not release any drug. Main results. In the drug eluting implants the scar layer was significantly thinner at all timepoints, and unlike the controls it did not continue to thicken after 6 months. Control implants supported axon regeneration well initially, but axon counts fell rapidly at later timepoints as scar thickened. Axon counts in drug eluting devices were initially much lower, but increased rather than declined and by one year were significantly higher than in controls. Significance. Drug elution offers a potential long term solution to the problem of performance degradation due to scarring around neural implants.

  13. Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: a multicenter, 12-month follow-up study of patients with chronic heart failure.

    PubMed

    Magalski, Anthony; Adamson, Philip; Gadler, Frederick; Böehm, Michael; Steinhaus, David; Reynolds, Dwight; Vlach, Kathryn; Linde, Cecilia; Cremers, Bodo; Sparks, Brandon; Bennett, Tom

    2002-04-01

    We describe the performance of an implantable hemodynamic monitor (IHM) that allows continuous recording of heart rate, patient activity levels, and right ventricular systolic, right ventricular diastolic, and estimated pulmonary artery diastolic pressures. Pressure parameters derived from the implantable monitor were correlated to measurements made with a balloon-tipped catheter to establish accuracy and reproducibility over time in patients with chronic heart failure (CHF). IHM devices were implanted in 32 patients with CHF (left ventricular ejection fraction, 29% +/- 11%; range, 14%-62%) and were tested with right heart catheterization at implantation and 3, 6, and 12 months later. Hemodynamic variables were digitally recorded simultaneously from the IHM and catheter. Values were recorded during supine rest, peak response of Valsalva maneuver, sitting, peak of a 2-stage (25-50 W) bicycle exercise test, and final rest period. The median of 21 paired beat-to-beat cardiac cycles was analyzed for each intervention. A total of 217 paired data values from all maneuvers were analyzed for 32 patients at implantation and 129 paired data values for 20 patients at 1 year. The IHM and catheter values were not different at baseline or at 1 year (P >.05). Combining all interventions, correlation coefficients were 0.96 and 0.94 for right ventricular systolic pressure, 0.96 and 0.83 for right ventricular diastolic pressure, and 0.87 and 0.87 for estimated pulmonary artery diastolic pressure at implantation and 1 year, respectively. The IHM and a standard reference pressure system recorded comparable right heart pressure values in patients with CHF. This implantable pressure transducer is accurate over time and provides a means to precisely monitor the hemodynamic condition of patients with CHF in a continuous fashion.

  14. A Fully Implantable Pacemaker for the Mouse: From Battery to Wireless Power

    PubMed Central

    Zellmer, Erik R.; Weinheimer, Carla J.; MacEwan, Matthew R.; Cui, Sophia X.; Nerbonne, Jeanne M.; Efimov, Igor R.

    2013-01-01

    Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice. PMID:24194832

  15. Angiogenic effects of borate glass microfibers in a rodent model.

    PubMed

    Lin, Yinan; Brown, Roger F; Jung, Steven B; Day, Delbert E

    2014-12-01

    The primary objective of this research was to evaluate the use of bioactive borate-based glass microfibers for angiogenesis in soft tissue repair applications. The effect of these fibers on growth of capillaries and small blood vessels was compared to that of 45S5 silica glass microfibers and sham implant controls. Compressed mats of three types of glass microfibers were implanted subcutaneously in rats and tissues surrounding the implant sites histologically evaluated 2-4 weeks post surgery. Bioactive borate glass 13-93B3 supplemented with 0.4 wt % copper promoted extensive angiogenesis as compared to silica glass microfibers and sham control tissues. The angiogenic responses suggest the copper-containing 13-93B3 microfibers may be effective for treating chronic soft tissue wounds. A second objective was to assess the possible systemic cytotoxicity of dissolved borate ions and other materials released from implanted borate glass microfibers. Cytotoxicity was assessed via histological evaluation of kidney tissue collected from animals 4 weeks after subcutaneously implanting high amounts of the borate glass microfibers. The evaluation of the kidney tissue from these animals showed no evidence of chronic histopathological changes in the kidney. The overall results indicate the borate glass microfibers are safe and effective for soft tissue applications. © 2014 Wiley Periodicals, Inc.

  16. Mesh electronics: a new paradigm for tissue-like brain probes.

    PubMed

    Hong, Guosong; Yang, Xiao; Zhou, Tao; Lieber, Charles M

    2018-06-01

    Existing implantable neurotechnologies for understanding the brain and treating neurological diseases have intrinsic properties that have limited their capability to achieve chronically-stable brain interfaces with single-neuron spatiotemporal resolution. These limitations reflect what has been dichotomy between the structure and mechanical properties of living brain tissue and non-living neural probes. To bridge the gap between neural and electronic networks, we have introduced the new concept of mesh electronics probes designed with structural and mechanical properties such that the implant begins to 'look and behave' like neural tissue. Syringe-implanted mesh electronics have led to the realization of probes that are neuro-attractive and free of the chronic immune response, as well as capable of stable long-term mapping and modulation of brain activity at the single-neuron level. This review provides a historical overview of a 10-year development of mesh electronics by highlighting the tissue-like design, syringe-assisted delivery, seamless neural tissue integration, and single-neuron level chronic recording stability of mesh electronics. We also offer insights on unique near-term opportunities and future directions for neuroscience and neurology that now are available or expected for mesh electronics neurotechnologies. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

    PubMed Central

    Yue, James J; Garcia, Rolando; Miller, Larry E

    2016-01-01

    Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration − the Charité Artificial Disc in 2004 and the ProDisc-L Total Disc Replacement in 2006. In June 2015, a next-generation lumbar TDR received Food and Drug Administration approval − the activL® Artificial Disc (Aesculap Implant Systems). Compared to previous-generation lumbar TDRs, the activL® Artificial Disc incorporates specific design enhancements that result in a more precise anatomical match and allow a range of motion that better mimics the healthy spine. The results of mechanical and clinical studies demonstrate that the activL® Artificial Disc results in improved mechanical and clinical outcomes versus earlier-generation artificial discs and compares favorably to lumbar fusion. The purpose of this report is to describe the activL® Artificial Disc including implant characteristics, intended use, surgical technique, postoperative care, mechanical testing, and clinical experience to date. PMID:27274317

  18. A Wireless Implantable Micropump for Chronic Drug Infusion Against Cancer

    PubMed Central

    Cobo, Angelica; Sheybani, Roya; Tu, Heidi; Meng, Ellis

    2016-01-01

    We present an implantable micropump with a miniature form factor and completely wireless operation that enables chronic drug administration intended for evaluation and development of cancer therapies in freely moving small research animals such as rodents. The low power electrolysis actuator avoids the need for heavy implantable batteries. The infusion system features a class E inductive powering system that provides on-demand activation of the pump as well as remote adjustment of the delivery regimen without animal handling. Micropump performance was demonstrated using a model anti-cancer application in which daily doses of 30 μL were supplied for several weeks with less than 6% variation in flow rate within a single pump and less than 8% variation across different pumps. Pumping under different back pressure, viscosity, and temperature conditions were investigated; parameters were chosen so as to mimic in vivo conditions. In benchtop tests under simulated in vivo conditions, micropumps provided consistent and reliable performance over a period of 30 days with less than 4% flow rate variation. The demonstrated prototype has potential to provide a practical solution for remote chronic administration of drugs to ambulatory small animals for research as well as drug discovery and development applications. PMID:26855476

  19. Modified titanium implant as a gateway to the human body: the implant mediated drug delivery system.

    PubMed

    Park, Young-Seok; Cho, Joo-Youn; Lee, Shin-Jae; Hwang, Chee Il

    2014-01-01

    The aim of this study was to investigate the efficacy of a proposed new implant mediated drug delivery system (IMDDS) in rabbits. The drug delivery system is applied through a modified titanium implant that is configured to be implanted into bone. The implant is hollow and has multiple microholes that can continuously deliver therapeutic agents into the systematic body. To examine the efficacy and feasibility of the IMDDS, we investigated the pharmacokinetic behavior of dexamethasone in plasma after a single dose was delivered via the modified implant placed in the rabbit tibia. After measuring the plasma concentration, the areas under the curve showed that the IMDDS provided a sustained release for a relatively long period. The result suggests that the IMDDS can deliver a sustained release of certain drug components with a high bioavailability. Accordingly, the IMDDS may provide the basis for a novel approach to treating patients with chronic diseases.

  20. Presence of Biofilms on Polyurethane-Coated Breast Implants: Preliminary Results.

    PubMed

    Rieger, Ulrich M; Djedovic, Gabriel; Pattiss, Alexander; Raschke, Gregor F; Frei, Reno; Pierer, Gerhard; Trampuz, Andrej

    2016-01-01

    Polyurethane-coated breast implants seem to be associated with lower medium- and long-term capsular contracture rates in comparison to textured or smooth implant surfaces. Although the etiology of capsular contracture is uncertain, bacterial biofilms have been suggested to trigger chronic peri-implant inflammation, eventually leading to capsular contracture. It is unknown whether polyurethane-coated implants are less prone to biofilm colonization than other implant surfaces. We extracted data from patient records included in a prospective cohort between 2008 and 2011. All patients who underwent removal of polyurethane-coated implants were included in this current study and screened for presence of biofilms by sonication. In addition, implant- and patient-related data were analyzed. Of the ten included polyurethane-coated breast implants, six had been inserted for reconstructive purposes and four for aesthetic reasons. The median implant indwelling time was 28.3 mo. Overall, sonication cultures were positive in 50% of implants. Propionibacterium acnes and coagulase-negative staphylococci were the predominant pathogens isolated from biofilm cultures. Like other implant surfaces, polyurethane-coated implants are prone to biofilm colonization. Further investigations are needed to determine why capsular contracture rates seem to be lower in polyurethane implants than in other implant surfaces. Notably, in this study, 40% of the implants were explanted from breasts with severe capsular contracture.

  1. Optical power transfer and communication methods for wireless implantable sensing platforms.

    PubMed

    Mujeeb-U-Rahman, Muhammad; Adalian, Dvin; Chang, Chieh-Feng; Scherer, Axel

    2015-09-01

    Ultrasmall scale implants have recently attracted focus as valuable tools for monitoring both acute and chronic diseases. Semiconductor optical technologies are the key to miniaturizing these devices to the long-sought sub-mm scale, which will enable long-term use of these devices for medical applications. This can also enable the use of multiple implantable devices concurrently to form a true body area network of sensors. We demonstrate optical power transfer techniques and methods to effectively harness this power for implantable devices. Furthermore, we also present methods for optical data transfer from such implants. Simultaneous use of these technologies can result in miniaturized sensing platforms that can allow for large-scale use of such systems in real world applications.

  2. Optical power transfer and communication methods for wireless implantable sensing platforms

    NASA Astrophysics Data System (ADS)

    Mujeeb-U-Rahman, Muhammad; Adalian, Dvin; Chang, Chieh-Feng; Scherer, Axel

    2015-09-01

    Ultrasmall scale implants have recently attracted focus as valuable tools for monitoring both acute and chronic diseases. Semiconductor optical technologies are the key to miniaturizing these devices to the long-sought sub-mm scale, which will enable long-term use of these devices for medical applications. This can also enable the use of multiple implantable devices concurrently to form a true body area network of sensors. We demonstrate optical power transfer techniques and methods to effectively harness this power for implantable devices. Furthermore, we also present methods for optical data transfer from such implants. Simultaneous use of these technologies can result in miniaturized sensing platforms that can allow for large-scale use of such systems in real world applications.

  3. Characterization of flexible ECoG electrode arrays for chronic recording in awake rats

    PubMed Central

    Yeager, John D.; Phillips, Derrick J.; Rector, David M.; Bahr, David F.

    2008-01-01

    We developed a 64 channel flexible polyimide ECoG electrode array and characterized its performance for long term implantation, chronic cortical recording and high resolution mapping of surface evoked potentials in awake rats. To achieve the longest possible recording periods, the flexibility of the electrode array, adhesion between the metals and carrier substrate, and biocompatibility was critical for maintaining the signal integrity. Experimental testing of thin film adhesion was applied to a gold – polyimide system in order to characterize relative interfacial fracture energies for several different adhesion layers, yielding an increase in overall device reliability. We tested several different adhesion techniques including: gold alone without an adhesion layer, titanium-tungsten, tantalum and chromium. We found the titanium-tungsten to be a suitable adhesion layer considering the biocompatibility requirements as well as stability and delamination resistance. While chromium and tantalum produced stronger gold adhesion, concerns over biocompatibility of these materials require further testing. We implanted the polyimide ECoG electrode arrays through a slit made in the skull of rats and recorded cortical surface evoked responses. The arrays performed reliably over a period of at least 100 days and signals compared well with traditional screw electrodes, with better high frequency response characteristics. Since the ultimate goal of chronically implanted electrode arrays is for neural prosthetic devices that need to last many decades, other adhesion layers that would prove safe for implantation may be tested in the same way in order to improve the device reliability. PMID:18640155

  4. Repair of a deep digital tendon deficit in a horse using a polypropylene implant.

    PubMed Central

    Crawford, W H; Ingle, J E

    1997-01-01

    A yearling horse was treated for a chronic wound with a 4 cm deficit in the deep digital tendon. The gap in the tendon was bridged with paired polypropylene braided implants designed for use as a ligament augmentation device. Uncomplicated healing and return to function occurred. Images Figure 1. PMID:9167878

  5. Role of plasma fibronectin in the foreign body response to biomaterials.

    PubMed

    Keselowsky, Benjamin G; Bridges, Amanda W; Burns, Kellie L; Tate, Ciara C; Babensee, Julia E; LaPlaca, Michelle C; García, Andrés J

    2007-09-01

    Host responses to biomaterials control the biological performance of implanted medical devices. Upon implantation, synthetic materials adsorb biomolecules, which trigger an inflammatory cascade comprising coagulation, leukocyte recruitment/adhesion, and foreign body reaction. The foreign body reaction and ensuing fibrous encapsulation severely limit the in vivo performance of numerous biomedical devices. While it is well established that plasma fibrinogen and secreted cytokines modulate leukocyte recruitment and maturation into foreign body giant cells, mediators of chronic inflammation and fibrous encapsulation of implanted biomaterials remain poorly understood. Using plasma fibronectin (pFN) conditional knock-out mice, we demonstrate that pFN modulates the foreign body response to polyethylene terephthalate disks implanted subcutaneously. Fibrous collagenous capsules were two-fold thicker in mice depleted of pFN compared to controls. In contrast, deletion of pFN did not alter acute leukocyte recruitment to the biomaterial, indicating that pFN modulates chronic fibrotic responses. The number of foreign body giant cells associated with the implant was three times higher in the absence of pFN while macrophage numbers were not different, suggesting that pFN regulates the formation of biomaterial-associated foreign body giant cells. Interestingly, cellular FN (cFN) was present in the capsules of both normal and pFN-depleted mice, suggesting that cFN could not compensate for the loss of pFN. These results implicate pFN in the host response to implanted materials and identify a potential target for therapeutic intervention to enhance the biological performance of biomedical devices.

  6. Meta-analysis of long-term outcomes of drug-eluting stent implantations for chronic total coronary occlusions.

    PubMed

    Ma, Jian; Yang, Weiwei; Singh, Manpreet; Peng, Tianqing; Fang, Ningyuan; Wei, Meng

    2011-01-01

    In the treatment of chronic total occlusions (CTOs), some uncertainty exists regarding the effect of drug-eluting stents (DESs) compared with the effects of bare mental stents (BMSs). We reviewed outcomes of DES vs. BMS implantation for CTO lesions, to evaluate the risk-benefit ratio of DES implantation. Relevant studies of long-term clinical outcomes or angiographic outcomes of both BMS and DES implantation were examined. The primary endpoint comprised major adverse cardiovascular events (MACEs), including all-cause deaths, myocardial infarctions (MIs), and target lesion revascularizations (TLRs). A fixed-effect model and random-effect model were used to analyze the pooling results. Ten studies were included according to the selection criteria. Eight were nonrandomized controlled trials, and two consisted of a randomized controlled comparison between DES and BMS implantation. No significant difference was evident for in-hospital MACE rates between the two groups (odds ratio [OR], 1.07; 95% confidence interval [CI], .53 to 2.13), but the long-term MACE rates in the DES group were significantly lower than in the BMS group (OR, .22; 95% CI, .13 to .38; P < .00001). The rates of stent restenosis and reocclusions were also significantly lower in the DES group (OR, .14; 95% CI, .09 to .20; and OR, .23; 95% CI, .12 to .41, respectively). Implantation of the DES improves long-term angiographic and clinical outcomes compared with BMS in the treatment of CTO lesions. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Multi-scale, multi-modal analysis uncovers complex relationship at the brain tissue-implant neural interface: new emphasis on the biological interface

    NASA Astrophysics Data System (ADS)

    Michelson, Nicholas J.; Vazquez, Alberto L.; Eles, James R.; Salatino, Joseph W.; Purcell, Erin K.; Williams, Jordan J.; Cui, X. Tracy; Kozai, Takashi D. Y.

    2018-06-01

    Objective. Implantable neural electrode devices are important tools for neuroscience research and have an increasing range of clinical applications. However, the intricacies of the biological response after implantation, and their ultimate impact on recording performance, remain challenging to elucidate. Establishing a relationship between the neurobiology and chronic recording performance is confounded by technical challenges related to traditional electrophysiological, material, and histological limitations. This can greatly impact the interpretations of results pertaining to device performance and tissue health surrounding the implant. Approach. In this work, electrophysiological activity and immunohistological analysis are compared after controlling for motion artifacts, quiescent neuronal activity, and material failure of devices in order to better understand the relationship between histology and electrophysiological outcomes. Main results. Even after carefully accounting for these factors, the presence of viable neurons and lack of glial scarring does not convey single unit recording performance. Significance. To better understand the biological factors influencing neural activity, detailed cellular and molecular tissue responses were examined. Decreases in neural activity and blood oxygenation in the tissue surrounding the implant, shift in expression levels of vesicular transporter proteins and ion channels, axon and myelin injury, and interrupted blood flow in nearby capillaries can impact neural activity around implanted neural interfaces. Combined, these tissue changes highlight the need for more comprehensive, basic science research to elucidate the relationship between biology and chronic electrophysiology performance in order to advance neural technologies.

  8. Effects of Intralaminar Thalamic Stimulation on Language Functions

    ERIC Educational Resources Information Center

    Bhatnagar, Subhash C.; Mandybur, George T.

    2005-01-01

    Fifteen neurosurgical subjects, who were undergoing thalamic chronic electrode implants as a treatment for dyskinesia and chronic pain, were evaluated on a series of neurolinguistic functions to determine if the stimulation of the centromedianum nucleus of the thalamus affected language and cognitive processing. Analysis of the data revealed that…

  9. High-fat diet exacerbates bone loss in mice implanted with low-dose slow-release lipopolysaccharide pellets

    USDA-ARS?s Scientific Manuscript database

    Obesity is associated with chronic up-regulation of inflammatory cytokines which stimulate osteoclast activity and bone resorption. Osteopenia or low bone mass is observed in a variety of physiological conditions with chronic inflammation including aging and post-menopause with estrogen deficiency. ...

  10. Impact of a chronic smoking habit on the osteo-immunoinflammatory mediators in the peri-implant fluid of clinically healthy dental implants.

    PubMed

    Negri, Brenno Marcondes; Pimentel, Suzana Peres; Casati, Marcio Zaffalon; Cirano, Fabiano Ribeiro; Casarin, Renato Correa; Ribeiro, Fernanda Vieira

    2016-10-01

    The aim of this study was to evaluate the influence of chronic cigarette smoking on the profile of osteo-immunoinflammatory markers in the peri-implant crevicular fluid (PICF) from clinically healthy implants DESIGNS: Twenty-five smokers and 23 non-smoker subjects with a unitary screwed implant-supported crown in the molar or pre-molar region were enrolled in this study. The implants should have been in functioning for at least 12 months, and the peri-implant tissue should be clinically healthy [probing depth (PD)<4mm with no bleeding on probing (BoP) and no evidence of radiographic bone loss beyond bone remodeling]. The levels of interferon (INF)-γ, interleukin (IL)-4, IL-17, IL-1β, IL-10, IL-6, IL-8, tumor necrosis factor (TNF)-α, matrix metalloproteinase (MMP)-2, MMP-9, osteoprotegerin (OPG), soluble receptor activator of nuclear factor-κβ ligand (RANKL), osteocalcin (OC), osteopontin (OPN), transforming growth factor (TGF)-β, and cross-linked telopeptide of type I collagen (ICTP) in the PICF were quantified by a multiplexed bead immunoassay. The smokers presented reduced levels of IL-4, IL-8, and TNF-α compared with the non-smoker individuals (p<0.05). In addition, although lower OPG levels were detected in the PICF of the smokers, the RANKL/OPG ratio did not show a significant difference (p>0.05). Moreover, higher ICTP concentrations and a higher TH1/TH2 ratio were observed in the PICF of the smoker patients (p<0.05). No differences between the groups were observed for the other markers evaluated (p>0.05). Smoking habit modulate peri-implant cytokine profile, leading to reductions in IL-4, -8 TNF-α, and OPG levels and an increased ICTP and TH1/TH2 ratio in peri-implant crevicular fluid. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Long-term imaging in awake mice using removable cranial windows

    PubMed Central

    Glickfeld, Lindsey L.; Kerlin, Aaron M.; Reid, R. Clay; Bonin, Vincent; Schafer, Dorothy P.; Andermann, Mark L.

    2015-01-01

    Cranial window implants in head-fixed rodents are becoming a preparation of choice for stable optical access to large areas of cortex over extended periods of time. Here, we provide a highly detailed and reliable surgical protocol for a cranial window implantation procedure for chronic widefield and cellular imaging in awake, head-fixed mice, which enables subsequent window removal and replacement in the weeks and months following the initial craniotomy. This protocol has facilitated awake, chronic imaging in adolescent as well as adult mice over several months from a large number of cortical brain regions; targeted virus and tracer injections from data obtained using prior awake functional mapping; and functionally-targeted two-photon imaging across all cortical layers in awake mice using a microprism attachment to the cranial window. Collectively, these procedures extend the reach of chronic imaging of cortical function and dysfunction in behaving animals. PMID:25275789

  12. Design, Fabrication, Characterization and Modeling of Integrated Functional Materials

    DTIC Science & Technology

    2013-10-01

    coated microwire to change the temperature of an FBG. We show below that the proposed sensor probe, with a relatively poor thermal coupling with FBG...Seebeck coefficient and decreased thermal conductivity due to the phenomenological properties of nanometer length scales, including enhanced...nanocomposites as compared to bulk polycrystalline materials, in addition to similar thermal conductivities , results in enhanced room temperature ZT as

  13. Combined current-modulation annealing induced enhancement of giant magnetoimpedance effect of Co-rich amorphous microwires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Jingshun, E-mail: jingshun-liu@163.com, E-mail: faxiang.qin@gmail.com; School of Materials Science and Engineering, Inner Mongolia University of Technology, Hohhot 010051; Qin, Faxiang, E-mail: jingshun-liu@163.com, E-mail: faxiang.qin@gmail.com

    2014-05-07

    We report on a combined current-modulation annealing (CCMA) method, which integrates the optimized pulsed current (PC) and DC annealing techniques, for improving the giant magnetoimpedance (GMI) effect and its field sensitivity of Co-rich amorphous microwires. Relative to an as-prepared Co{sub 68.2}Fe{sub 4.3}B{sub 15}Si{sub 12.5} wire, CCMA is shown to remarkably improve the GMI response of the wire. At 10 MHz, the maximum GMI ratio and its field sensitivity of the as-prepared wire were, respectively, increased by 3.5 and 2.28 times when subjected to CCMA. CCMA increased atomic order orientation and circumferential permeability of the wire by the co-action of high-density pulsedmore » magnetic field energy and thermal activation energy at a PC annealing stage, as well as the formation of uniform circular magnetic domains by a stable DC magnetic field at a DC annealing stage. The magnetic moment can overcome eddy-current damping or nail-sticked action in rotational magnetization, giving rise to a double-peak feature and wider working field range (up to ±2 Oe) at relatively higher frequency (f ≥ 1 MHz)« less

  14. Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording

    PubMed Central

    Kozai, Takashi D. Y.; Catt, Kasey; Li, Xia; Gugel, Zhannetta V.; Olafsson, Valur T.; Vazquez, Alberto L.; Cui, X. Tracy

    2014-01-01

    Penetrating intracortical electrode arrays that record brain activity longitudinally are powerful tools for basic neuroscience research and emerging clinical applications. However, regardless of the technology used, signals recorded by these electrodes degrade over time. The failure mechanisms of these electrodes are understood to be a complex combination of the biological reactive tissue response and material failure of the device over time. While mechanical mismatch between the brain tissue and implanted neural electrodes have been studied as a source of chronic inflammation and performance degradation, the electrode failure caused by mechanical mismatch between different material properties and different structural components within a device have remained poorly characterized. Using Finite Element Model (FEM) we simulate the mechanical strain on a planar silicon electrode. The results presented here demonstrate that mechanical mismatch between iridium and silicon leads to concentrated strain along the border of the two materials. This strain is further focused on small protrusions such as the electrical traces in planar silicon electrodes. These findings are confirmed with chronic in vivo data (133–189 days) in mice by correlating a combination of single-unit electrophysiology, evoked multi-unit recordings, electrochemical impedance spectroscopy, and scanning electron microscopy from traces and electrode sites with our modeling data. Several modes of mechanical failure of chronically implanted planar silicon electrodes are found that result in degradation and/or loss of recording. These findings highlight the importance of strains and material properties of various subcomponents within an electrode array. PMID:25453935

  15. Imunohistological aspects of the tissue around dental implants

    NASA Astrophysics Data System (ADS)

    Nimigean, Victor; Nimigean, Vanda R.; Sǎlǎvǎstru, Dan I.; Moraru, Simona; BuÅ£incu, Lavinia; Ivaşcu, Roxana V.; Poll, Alexandru

    2016-03-01

    Objectives: study of soft and hard tissues around implants. Material and methods: For the immunohistochemical and histological study of the implant/soft tissue interface, we examined pieces of peri-implant mucosa harvested from 35 patients. The implant/bone interface was assessed using histologic and histomorphometric examination of hard tissues around unloaded, early loaded or delayed loaded dental implants with pre-established design, with a sandblasted and acid-etched surface, placed both in extraction sockets, or after bone healing following tooth removal. This study was performed on 9 common race dogs. Results: The histological study of the implant/soft tissue interface showed regenerative modifications and moderate chronic subepithelial inflammatory reactions. Immunohistochemical evaluation of the soft tissue biopsies revealed the presence of specific immunocompetent cells and proteins of the matrix metalloproteinase (MMP) expression. Bone-implants contacts were more obvious in the apical half of the implants and at the edges of the threads, than between them. A mature, lamelliform bone containing lacunae with osteocytes and lack of connective tissue were noticed around implants that were late placed and loaded. The new-formed bone was also abundant in the crestal zone, not only in the apical part of the implants. Conclusions: A thorough understanding of the microstructure of dental implant/soft and hard tissue interface will improve the longevity of osseointegrated implants.

  16. Percutaneous valved stent implantation in the ascending aorta for the treatment of very high-risk aortic regurgitation: an animal study.

    PubMed

    Zong, Gang-Jun; Jiang, Hai-Bin; Bai, Yuan; Wu, Gang-Yong; Ye, Guang-Ming; Chen, Jing-Kai; Qin, Yong-Wen; Zhao, Xian-xian

    2013-12-01

    We investigated the effects of percutaneous valved stent implantation in the ascending aorta as an alternative treatment for aortic regurgitation in a canine model. A total of 16 healthy dogs weighing an average of 18.3 ± 2.1 kg were used for the establishment of animal models of chronic aortic regurgitation by percutaneous aortic valve perforation and balloon dilation. At 2 mo after successful model establishment, all experimental animals underwent valved stent implantation in the ascending aorta and then were followed up for 3 mo. Experimental models of chronic aortic regurgitation were successfully established in 10 dogs. Surviving dogs underwent successful valved stent implantation in the ascending aorta and were subsequently followed up for 3 mo. The level of instantaneous aortic regurgitation at 3-mo follow-up was significantly reduced compared with that before valved stent implantation (2.4 ± 0.9 versus 10.6 ± 2.1 mL/s, P < 0.05). The left ventricular ejection fraction was significantly increased (53.8 ± 4.2% versus 37.8 ± 3.7%, P < 0.05), and the left ventricular end-diastolic volume was also significantly reduced (30.3 ± 2.2 versus 40.1 ± 3.6 mL, P < 0.05). No paravalvular leak, stroke, atrioventricular block, or other complications occurred in dogs undergoing valved stent implantation. Percutaneous valved stent implantation in the ascending aorta is feasible, effective, and safe as an alternative treatment for very high-risk aortic regurgitation in a canine model. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Reaction of the rat tissues to implantation of polyhydroxyalkanoate films and ultrafine fibers.

    PubMed

    Maiborodin, I V; Shevela, A I; Morozov, V V; Novikova, Ya V; Matveeva, V A; Drovosekov, M N; Barannik, M I

    2013-01-01

    The reaction of various tissues of rats to implantation of polyhydroxyalkanoate films and ultrafine fibers was studied by optic microscopy. Implantation of polyhydroxyalkanoate films into the abdominal cavity caused a peritoneal reaction, leading after 1 month to the formation of fibrous adhesions between polyhydroxyalkanoate and intestinal loops. Under the skin and in the muscle tissue polyhydroxyalkanoate films were encapsulated in a thick fibrous capsule. Implantation of polyhydroxyalkanoate ultrathin fibers led to formation of foreign body granulomas in all tissues with perifocal inflammation and sclerosis of the adjacent tissues. The polymer was fragmented in these granulomas and phagocytosed by macrophages with the formation of giant foreign body cells. Hence, polyhydroxyalkanoate materials implanted in vivo caused chronic granulomatous inflammatory reaction and were very slowly destroyed by macrophages.

  18. Anatomical and functional evaluation of tympanoplasty using a transitory natural latex biomembrane implant from the rubber tree Hevea brasiliensis.

    PubMed

    Araujo, Marcos Miranda; Massuda, Eduardo Tanaka; Hyppolito, Miguel Angelo

    2012-08-01

    To compare the role of transitory latex and sylastic® implants in tympanoplasty on the closure of tympanic perforations. A randomized double-blind prospective study was conducted on 107 patients with chronic otitis media submitted to underlay tympanoplasty and divided at random into three groups: control with no transitory implant, latex membrane group, and sylastic® membrane group. Greater graft vascularization occurred in the latex membrane group (p<0.05). Good biocompatibility was obtained with the use of the latex and silicone implants, with no effect on the occurrence of infection, otorrhea or otorragy. The use of a transitory latex implant induced greater graft vascularization, with a biocompatible interaction with the tissue of the human tympanic membrane.

  19. Intrasocket reactive soft tissue for primary closure after augmentation of extraction sites with severe bone loss before implant placement.

    PubMed

    Mardinger, Ofer; Chaushu, Gavriel; Ghelfan, Oded; Nissan, Joseph

    2009-06-01

    The normal bone resorption after tooth extraction can be significantly aggravated in the case of pre-existing severe bone loss and chronic infection. Bone augmentation procedures have been proposed, but they require adequate closure of soft tissues. We propose the use of intrasocket reactive tissue to cover extraction sites augmented by bovine bone mineral graft to promote the success of the graft procedure. The study included 24 patients with severe bone loss and chronic pathology in 27 sites. The intrasocket reactive soft tissue was elevated from the bony walls in a subperiosteal plane. Porous bovine or allograft bone mineral was placed in the extraction site without membranes, and the intrasocket reactive soft tissue was sutured over the grafting material to seal the coronal portion of the socket. Twenty-seven implants were placed 6 months after bone augmentation. Healing progressed uneventfully. Postoperative morbidity was minimal. There was no leakage or infection of the grafting material. The mean time to implant placement was 7.8 months. Supplemental augmentation was not needed. There were no implant failures. Follow-up ranged from 6 to 36 months (mean, 15 months). All implants were rehabilitated with fixed prostheses. Intrasocket reactive soft tissue can be used predictably to obtain primary closure of augmented extraction sites with severe bone loss with minimal postoperative morbidity.

  20. Modified endoscopic medial maxillectomy for zygomatic implant salvage.

    PubMed

    Schwartz, Joseph S; Tajudeen, Bobby A; Adappa, Nithin D; Palmer, James N

    2016-01-01

    Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant.

  1. An implantable integrated low-power amplifier-microelectrode array for Brain-Machine Interfaces.

    PubMed

    Patrick, Erin; Sankar, Viswanath; Rowe, William; Sanchez, Justin C; Nishida, Toshikazu

    2010-01-01

    One of the important challenges in designing Brain-Machine Interfaces (BMI) is to build implantable systems that have the ability to reliably process the activity of large ensembles of cortical neurons. In this paper, we report the design, fabrication, and testing of a polyimide-based microelectrode array integrated with a low-power amplifier as part of the Florida Wireless Integrated Recording Electrode (FWIRE) project at the University of Florida developing a fully implantable neural recording system for BMI applications. The electrode array was fabricated using planar micromachining MEMS processes and hybrid packaged with the amplifier die using a flip-chip bonding technique. The system was tested both on bench and in-vivo. Acute and chronic neural recordings were obtained from a rodent for a period of 42 days. The electrode-amplifier performance was analyzed over the chronic recording period with the observation of a noise floor of 4.5 microVrms, and an average signal-to-noise ratio of 3.8.

  2. Chronic monitoring of lower urinary tract activity via a sacral dorsal root ganglia interface

    NASA Astrophysics Data System (ADS)

    Khurram, Abeer; Ross, Shani E.; Sperry, Zachariah J.; Ouyang, Aileen; Stephan, Christopher; Jiman, Ahmad A.; Bruns, Tim M.

    2017-06-01

    Objective. Our goal is to develop an interface that integrates chronic monitoring of lower urinary tract (LUT) activity with stimulation of peripheral pathways. Approach. Penetrating microelectrodes were implanted in sacral dorsal root ganglia (DRG) of adult male felines. Peripheral electrodes were placed on or in the pudendal nerve, bladder neck and near the external urethral sphincter. Supra-pubic bladder catheters were implanted for saline infusion and pressure monitoring. Electrode and catheter leads were enclosed in an external housing on the back. Neural signals from microelectrodes and bladder pressure of sedated or awake-behaving felines were recorded under various test conditions in weekly sessions. Electrodes were also stimulated to drive activity. Main results. LUT single- and multi-unit activity was recorded for 4-11 weeks in four felines. As many as 18 unique bladder pressure single-units were identified in each experiment. Some channels consistently recorded bladder afferent activity for up to 41 d, and we tracked individual single-units for up to 23 d continuously. Distension-evoked and stimulation-driven (DRG and pudendal) bladder emptying was observed, during which LUT sensory activity was recorded. Significance. This chronic implant animal model allows for behavioral studies of LUT neurophysiology and will allow for continued development of a closed-loop neuroprosthesis for bladder control.

  3. Polyetheretherketone (PEEK) intervertebral cage as a cause of chronic systemic allergy: a case report.

    PubMed

    Maldonado-Naranjo, Andres L; Healy, Andrew T; Kalfas, Iain H

    2015-07-01

    Polyetheretherketone (PEEK) is an organic polymer thermoplastic with strong mechanical and chemical resistance properties. It has been used in industry to fabricate items for demanding applications such as bearings, piston parts, compressor plate valves, and cable insulation. Since the early 1980s, polyetheretherketone polymers have been increasingly used in orthopedic and spinal surgery applications. Numerous studies and years of clinical experience have confirmed the biocompatibility of this material. The purpose of the study was to report a case of chronic systemic allergy after anterior cervical decompression and fusion (ACDF) and implantation of an intervertebral PEEK cage, with resolution of symptoms after removal of PEEK cage. This study is a case report with clinical evidence for allergy to PEEK. The methods involve clinical findings and review of current literature. After ACDF and implantation of an intervertebral PEEK cage, the patient had developed an angioedema-like picture marked by severe redness, itching, swelling of his tongue, and skin thickening. A skin patch test was positive for PEEK. Removal of the implant resulted in the resolution of his allergy symptoms shortly after surgery. Tissue reactions to PEEK are extremely rare. Herein, we present the first report of a chronic allergic response to interbody PEEK material. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Safety and feasibility of chronic transvenous phrenic nerve stimulation for treatment of central sleep apnea in heart failure patients.

    PubMed

    Zhang, Xilong; Ding, Ning; Ni, Buqing; Yang, Bing; Wang, Hong; Zhang, Shi-Jiang

    2017-03-01

    Central sleep apnea (CSA) is common in patients with heart failure (HF) and is associated with poor quality of life and prognosis. Early acute studies using transvenous phrenic nerve stimulation (PNS) to treat CSA in HF have shown a significantly reduction of CSA and improvement of key polysomnographic parameters. In this study, we evaluated the safety of and efficiency chronic transvenous PNS with an implanted neurostimulator in HF patients with CSA. This study was a prospective, nonrandomized evaluation of unilateral transvenous PNS in eight HF patients with CSA. The stimulation lead, which connected to a proprietary neurostimulator, was positioned in either the left pericardiophrenic or right brachiocephalic vein. Monitoring during implantation and 6-monthly follow-ups were performed. Six of the implanted eight patients completed the study (one was lost to follow-up; one died from pneumonia). Neither side effects nor adverse events related to stimulation occurred. During the 6-monthly follow-ups, one patient had a lead dislodgement in the first month and the lead was subsequently repositioned. No additional lead dislodgements occurred. There were no significant changes in sleep habits, appetite, bleeding or infections. Compared with the parameters before stimulator implantation, there were significant improvement in apnea-hypopnea index, central apnea index, left ventricular ejection fraction and 6-min walk distance (all P < 0.01). Use of chronic transvenous PNS appears to be safe and feasible in HF patients with CSA. Large multicenter studies are needed to confirm safety and efficacy in this population. © 2015 John Wiley & Sons Ltd.

  5. Differential Changes in Expression of Stress- and Metabolic-Related Neuropeptides in the Rat Hypothalamus during Morphine Dependence and Withdrawal

    PubMed Central

    Núnez, Cristina; Zelei, Edina; Polyák, Ágnes; Milanés, M. Victoria

    2013-01-01

    Chronic morphine treatment and naloxone precipitated morphine withdrawal activates stress-related brain circuit and results in significant changes in food intake, body weight gain and energy metabolism. The present study aimed to reveal hypothalamic mechanisms underlying these effects. Adult male rats were made dependent on morphine by subcutaneous implantation of constant release drug pellets. Pair feeding revealed significantly smaller weight loss of morphine treated rats compared to placebo implanted animals whose food consumption was limited to that eaten by morphine implanted pairs. These results suggest reduced energy expenditure of morphine-treated animals. Chronic morphine exposure or pair feeding did not significantly affect hypothalamic expression of selected stress- and metabolic related neuropeptides - corticotropin-releasing hormone (CRH), urocortin 2 (UCN2) and proopiomelanocortin (POMC) compared to placebo implanted and pair fed animals. Naloxone precipitated morphine withdrawal resulted in a dramatic weight loss starting as early as 15–30 min after naloxone injection and increased adrenocorticotrophic hormone, prolactin and corticosterone plasma levels in morphine dependent rats. Using real-time quantitative PCR to monitor the time course of relative expression of neuropeptide mRNAs in the hypothalamus we found elevated CRH and UCN2 mRNA and dramatically reduced POMC expression. Neuropeptide Y (NPY) and arginine vasopressin (AVP) mRNA levels were transiently increased during opiate withdrawal. These data highlight that morphine withdrawal differentially affects expression of stress- and metabolic-related neuropeptides in the rat hypothalamus, while relative mRNA levels of these neuropeptides remain unchanged either in rats chronically treated with morphine or in their pair-fed controls. PMID:23805290

  6. Impact of chronic kidney disease on mortality in older adults treated with pacemaker implantation

    PubMed Central

    Fabbian, Fabio; De Giorgi, Alfredo; Guarino, Matteo; Malagù, Michele; Bertini, Matteo

    2017-01-01

    Objective To investigate whether chronic kidney disease could negatively impact survival in older adults needing pacemaker implantation after admission for bradyarrhythmias. Methods This retrospective observational study considered 538 older adults consecutively admitted, who had been followed-up for 31 ± 20 months. Subjects with poor short-term prognosis were excluded. Charlson comorbidity index (CCI) and estimated glomerular filtration rate (eGFR) was calculated, along with the independent relationship between all-cause mortality and clinical data. Hazard Ratio (HR) was calculated by Cox regression analysis. Results Mean age of the population was 85 ± 3.7 years, and causes for implantation were atrioventricular block in 51.9% and other bradyarrhythmias in 48.1% of cases. Mean eGFR was 58.3 ± 24 mL/min per 1.73 m2, and mean CCI was 3.65 ± 2.28. Death for all-causes was recorded in 213 subjects. Deceased patients were older, had lower eGFR, higher comorbidity, higher prevalence of myocardial infarction, congestive heart failure, cerebrovascular disease, dementia and chronic pulmonary disease. Age (HR: 1.081, 95% CI: 1.044–1.119; P < 001), CCI (HR: 1.651, 95% CI: 1.286–2.121, P < 001) and eGFR ≤ 45 mL/min per 1.73 m2 (HR: 1.360, 95% CI: 1.024–1.806; P = 0.033) were predictors of death. Conclusions Renal dysfunction, as well as comorbidity, impacts negatively survival of older adults treated with pacemaker implantation because of bradyarrhythmias. PMID:29238360

  7. [A physiological investigation of chronic electrical stimulation with scala tympani electrodes in kittens].

    PubMed

    Ni, D

    1992-12-01

    A physiological investigation of cochlear electrical stimulation was undertaken in six two-month-old kittens. The scala tympani electrodes were implanted and electrically stimulated using biphasic balanced electrical pulses for periods of 1000-1500h in four ears. Four ears received implants for same period but without electrical stimulation. The other two ears served as normal control. The results indicated: 1) Chronic electrical stimulation of the cochlea within electrochemically safe limits did not influence the hearing of kittens and the normal delivery of impulses evoked by acoustic and electrical signals on the auditory brainstem pathway. 2) The wave shapes of EABRs were similar to those of ABRs. The amplitudes of EABRs showed a significant increase following chronic electrical stimulation, resulting in a leftward shift in the input/output function. The absolute latencies and interwave latencies of waves II-III, III-IV and II-IV were significantly shorter than those of ABRs. These results imply that there was no adverse effect of chronic electrical stimulation on the maturing auditory systems of kittens using these electrical parameters and the mechanism of electrical hearing should be further studied.

  8. Efficacy of transverse tripolar stimulation for relief of chronic low back pain: results of a single center.

    PubMed

    Slavin, K V; Burchiel, K J; Anderson, V C; Cooke, B

    1999-01-01

    The goal of this study was to evaluate the efficacy of the transverse tripolar spinal cord stimulation system (TTS) in providing relief of low back pain in patients with chronic non-malignant pain. Transverse tripolar electrodes were implanted in the lower thoracic region (T(8-9) to T(12)-L(1)) in 10 patients with chronic neuropathic pain, all of whom reported a significant component of low back pain in combination with unilateral or bilateral leg pain. One patient reported inadequate pain relief during the trial and was not implanted with a permanent generator. A visual analogue scale of low back pain showed a nonsignificant decrease from 64 +/- 19 to 47 +/- 30 (p = 0.25; paired t test) after 1 month of stimulation. Similarly, functional disability evaluated using Oswestry Low Back Pain Questionnaire was not improved (p = 0. 46; paired t test). We conclude that chronic low back pain is not particularly responsive to the transverse stimulation provided by the TTS system. Copyright 2000 S. Karger AG, Basel

  9. Preventing neuronal damage and inflammation in vivo during cortical microelectrode implantation through the use of Poloxamer P-188

    NASA Astrophysics Data System (ADS)

    Misra, A.; Kondaveeti, P.; Nissanov, J.; Barbee, K.; Shewokis, P.; Rioux, L.; Moxon, K. A.

    2013-02-01

    Objective. The aim of this study was to test the efficacy of Poloxamer P188 to reduce cell death and immune response associated with mechanical trauma to cells during implantation of a chronic recording electrode. Approach. Ceramic multi-site recording electrodes were implanted bilaterally into 15 adult male Long-Evans rats. One of each pair was randomly assigned to receive a coating of Poloxamer while the other was treated with saline. The extent of neuron loss, and glial cell recruitment were characterized at 2, 4 and 6 weeks post-implantation by stereologic analysis. Main results. At 2 and 4 weeks post-implantation, Poloxamer-coated implants showed significantly fewer glial cells and more neurons in the peri-electrode space than controls; however, this significance was lost by 6 weeks. Significance. These findings are the first to suggest that Poloxamer has neuroprotective effects in vivo; however, at a fixed loading dose, these effects are limited to approximately 1 month post-implantation.

  10. Covalent bonding of YIGSR and RGD to PEDOT/PSS/MWCNT-COOH composite material to improve the neural interface.

    PubMed

    Wang, Kun; Tang, Rong-Yu; Zhao, Xiao-Bo; Li, Jun-Jie; Lang, Yi-Ran; Jiang, Xiao-Xia; Sun, Hong-Ji; Lin, Qiu-Xia; Wang, Chang-Yong

    2015-11-28

    The development of coating materials for neural interfaces has been a pursued to improve the electrical, mechanical and biological performances. For these goals, a bioactive coating was developed in this work featuring a poly(3,4-ethylenedioxythiophene) (PEDOT)/carbon nanotube (CNT) composite and covalently bonded YIGSR and RGD. Its biological effect and electrical characteristics were assessed in vivo on microwire arrays (MWA). The coated electrodes exhibited a significantly higher charge storage capacity (CSC) and lower electrochemical impedance at 1 kHz which are desired to improve the stimulating and recording performances, respectively. Acute neural recording experiments revealed that coated MWA possess a higher signal/noise ratio capturing spikes undetected by uncoated electrodes. Moreover, coated MWA possessed more active sites and single units, and the noise floor of coated electrodes was lower than that of uncoated electrodes. There is little information in the literature concerning the chronic performance of bioactively modified neural interfaces in vivo. Therefore in this work, chronic in vivo tests were conducted and the PEDOT/PSS/MWCNT-polypeptide coated arrays exhibited excellent performances with the highest mean maximal amplitude from day 4 to day 12 during which the acute response severely compromised the performance of the electrodes. In brief, we developed a simple method of covalently bonding YIGSR and RGD to a PEDOT/PSS/MWCNT-COOH composite improving both the biocompatibility and electrical performance of the neural interface. Our findings suggest that YIGSR and RGD modified PEDOT/PSS/MWCNT is a promising bioactivated composite coating for neural recording and stimulating.

  11. Biology of teeth and implants: Host factors - pathology, regeneration, and the role of stem cells.

    PubMed

    Eggert, F-Michael; Levin, Liran

    2018-01-01

    In chronic periodontitis and peri-implantitis, cells of the innate and adaptive immune systems are involved directly in the lesions within the tissues of the patient. Absence of a periodontal ligament around implants does not prevent a biologic process similar to that of periodontitis from affecting osseointegration. Our first focus is on factors in the biology of individuals that are responsible for the susceptibility of such individuals to chronic periodontitis and to peri-implantitis. Genetic factors are of significant importance in susceptibility to these diseases. Genetic factors of the host affect the composition of the oral microbiome in the same manner that they influence other microbiomes, such as those of the intestines and of the lungs. Our second focus is on the central role of stem cells in tissue regeneration, in the functioning of innate and adaptive immune systems, and in metabolism of bone. Epithelial cell rests of Malassez (ERM) are stem cells of epithelial origin that maintain the periodontal ligament as well as the cementum and alveolar bone associated with the ligament. The tissue niche within which ERM are found extends into the supracrestal areas of collagen fiber-containing tissues of the gingivae above the bony alveolar crest. Maintenance and regeneration of all periodontal tissues involves the activity of a variety of stem cells. The success of dental implants indicates that important groups of stem cells in the periodontium are active to enable that biologic success. Successful replantation of avulsed teeth and auto-transplantation of teeth is comparable to placing dental implants, and so must also involve periodontal stem cells. Biology of teeth and biology of implants represents the biology of the various stem cells that inhabit specialized niches within the periodontal tissues. Diverse biologic processes must function together successfully to maintain periodontal health. Osseointegration of dental implants does not involve formation of cementum or collagen fibers inserted into cementum - indicating that some stem cells are not active around dental implants or their niches are not available. Investigation of these similarities and differences between teeth and implants will help to develop a better understanding of the biology and physiologic functioning of the periodontium.

  12. Cochlear implantation in chronic demyelinating inflammatory polyneuropathy.

    PubMed

    Mowry, Sarah E; King, Sarah

    2017-03-01

    To describe a case of chronic inflammatory demyelinating polyneuropathy (CDIP) with bilateral sudden sensorineural hearing loss who subsequently benefited from unilateral cochlear implantation. case history review and review of the literature for the terms CDIP, hearing loss, cochleovestibular dysfunction, and cochlear implantation. A 49-year-old woman presented with bilateral rapidly progressive sensorineural hearing loss (SNHL) 1 month after an upper respiratory tract infection. Hearing loss was not responsive to high-dose steroids and there were no other laboratory abnormalities or physical findings. Within 1 month, she developed ascending motor palsy, requiring long-term ventilator support. This neurologic condition was diagnosed as CDIP and she was successfully treated with plasmapheresis and intravenous immunoglobulin. Her hearing never recovered. At the time of cochlear implant, she had no response at the limits of the audiometer and obtained 0% on AzBio testing. No ABR could be recorded preoperatively. She underwent uneventful cochlear implantation with a perimodilar electrode. One year after activation, she had a PTA of 20 dB and 40% on AzBio sentence testing. Her eABR demonstrated a neuropathy pattern. Only two other cases of CDIP associated with dysfunction of the eighth nerve have been described, and neither had documented profound hearing loss. Severe SNHL associated with CDIP is rare. Although this patient has good access to sound, speech discrimination is poor at 1-year post implantation. This outcome may be due to incomplete recovery of myelination of the eighth nerve. Other possibilities include loss of peripheral nerve fibers due to the initial viral upper respiratory infection, which may lead to less neural substrate to stimulate.

  13. Restoration of middle-ear input in fluid-filled middle ears by controlled introduction of air or a novel air-filled implant.

    PubMed

    Ravicz, Michael E; Chien, Wade W; Rosowski, John J

    2015-10-01

    The effect of small amounts of air on sound-induced umbo velocity in an otherwise saline-filled middle ear (ME) was investigated to examine the efficacy of a novel balloon-like air-filled ME implant suitable for patients with chronically non-aerated MEs. In this study, air bubbles or air-filled implants were introduced into saline-filled human cadaveric MEs. Umbo velocity, a convenient measure of ME response, served as an indicator of hearing sensitivity. Filling the ME with saline reduced umbo velocity by 25-30 dB at low frequencies and more at high frequencies, consistent with earlier work (Ravicz et al., Hear. Res. 195: 103-130 (2004)). Small amounts of air (∼30 μl) in the otherwise saline-filled ME increased umbo velocity substantially, to levels only 10-15 dB lower than in the dry ME, in a frequency- and location-dependent manner: air in contact with the tympanic membrane (TM) increased umbo velocity at all frequencies, while air located away from the TM increased umbo velocity only below about 500 Hz. The air-filled implant also affected umbo velocity in a manner similar to an air bubble of equivalent compliance. Inserting additional implants into the ME had the same effect as increasing air volume. These results suggest these middle-ear implants would significantly reduce conductive hearing loss in patients with chronically fluid-filled MEs. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Triangular stimulation method utilizing combination spinal cord stimulation with peripheral subcutaneous field stimulation for chronic pain patients: a retrospective study.

    PubMed

    Navarro, Rosa M; Vercimak, Danika C

    2012-01-01

    This retrospective data collection study aims to evaluate the responses of patients who have been implanted with a neuromodulation system using a combination of spinal cord stimulation (SCS) and peripheral subcutaneous field stimulation (PSFS) leads for chronic intractable pain. Forty patients with chronic, intractable pain implanted with both SCS and PSFS leads were enrolled in a retrospective data collection study. Pre-implant data (demographics, pain levels, pain location, and medication use) and post-implant data (pain levels, medication use, and device programming reports) were compared to measure short- and long-term improvements in pain for a period of approximately six months. Device system use and parameter data were collected. The majority of patients experienced immediate and short-term pain relief and reduction in oral pain medications as a result of combination SCS/PSFS therapy. The improvements were maintained for some, but not all patients by six months. Patients cycled through multiple programs over follow-up; the use of triangular stimulation was consistent over time, and by six months, patients preferred this program over others. Limitations of the retrospective chart review included missing data and variable follow-up times, and may have made determinations of long-term efficacy difficult. This study demonstrates that combination SCS and PSFS therapy is potentially a beneficial treatment option for reducing pain levels and oral pain medication compared with baseline in previously resistive chronic pain patients. There is a need for further study of this therapy in a greater number of subjects and in a prospective, controlled setting. In the author's general experience, triangular stimulation is very effective for treating isolated low back pain, because it covers larger topographic areas of the lower back than flow or field stimulation. An investigational device exemption study will be necessary for subcutaneous field stimulation indicated for focal isolated pain to be adequately investigated and utilized by physicians in the future. © 2012 International Neuromodulation Society.

  15. Chronic Electrical Stimulation with a Suprachoroidal Retinal Prosthesis: A Preclinical Safety and Efficacy Study

    PubMed Central

    Nayagam, David A. X.; Williams, Richard A.; Allen, Penelope J.; Shivdasani, Mohit N.; Luu, Chi D.; Salinas-LaRosa, Cesar M.; Finch, Sue; Ayton, Lauren N.; Saunders, Alexia L.; McPhedran, Michelle; McGowan, Ceara; Villalobos, Joel; Fallon, James B.; Wise, Andrew K.; Yeoh, Jonathan; Xu, Jin; Feng, Helen; Millard, Rodney; McWade, Melanie; Thien, Patrick C.; Williams, Chris E.; Shepherd, Robert K.

    2014-01-01

    Purpose To assess the safety and efficacy of chronic electrical stimulation of the retina with a suprachoroidal visual prosthesis. Methods Seven normally-sighted feline subjects were implanted for 96–143 days with a suprachoroidal electrode array and six were chronically stimulated for 70–105 days at levels that activated the visual cortex. Charge balanced, biphasic, current pulses were delivered to platinum electrodes in a monopolar stimulation mode. Retinal integrity/function and the mechanical stability of the implant were assessed monthly using electroretinography (ERG), optical coherence tomography (OCT) and fundus photography. Electrode impedances were measured weekly and electrically-evoked visual cortex potentials (eEVCPs) were measured monthly to verify that chronic stimuli were suprathreshold. At the end of the chronic stimulation period, thresholds were confirmed with multi-unit recordings from the visual cortex. Randomized, blinded histological assessments were performed by two pathologists to compare the stimulated and non-stimulated retina and adjacent tissue. Results All subjects tolerated the surgical and stimulation procedure with no evidence of discomfort or unexpected adverse outcomes. After an initial post-operative settling period, electrode arrays were mechanically stable. Mean electrode impedances were stable between 11–15 kΩ during the implantation period. Visually-evoked ERGs & OCT were normal, and mean eEVCP thresholds did not substantially differ over time. In 81 of 84 electrode-adjacent tissue samples examined, there were no discernible histopathological differences between stimulated and unstimulated tissue. In the remaining three tissue samples there were minor focal fibroblastic and acute inflammatory responses. Conclusions Chronic suprathreshold electrical stimulation of the retina using a suprachoroidal electrode array evoked a minimal tissue response and no adverse clinical or histological findings. Moreover, thresholds and electrode impedance remained stable for stimulation durations of up to 15 weeks. This study has demonstrated the safety and efficacy of suprachoroidal stimulation with charge balanced stimulus currents. PMID:24853376

  16. A partial hearing animal model for chronic electro-acoustic stimulation

    NASA Astrophysics Data System (ADS)

    Irving, S.; Wise, A. K.; Millard, R. E.; Shepherd, R. K.; Fallon, J. B.

    2014-08-01

    Objective. Cochlear implants (CIs) have provided some auditory function to hundreds of thousands of people around the world. Although traditionally carried out only in profoundly deaf patients, the eligibility criteria for implantation have recently been relaxed to include many partially-deaf patients with useful levels of hearing. These patients receive both electrical stimulation from their implant and acoustic stimulation via their residual hearing (electro-acoustic stimulation; EAS) and perform very well. It is unclear how EAS improves speech perception over electrical stimulation alone, and little evidence exists about the nature of the interactions between electric and acoustic stimuli. Furthermore, clinical results suggest that some patients that undergo cochlear implantation lose some, if not all, of their residual hearing, reducing the advantages of EAS over electrical stimulation alone. A reliable animal model with clinically-relevant partial deafness combined with clinical CIs is important to enable these issues to be studied. This paper outlines such a model that has been successfully used in our laboratory. Approach. This paper outlines a battery of techniques used in our laboratory to generate, validate and examine an animal model of partial deafness and chronic CI use. Main results. Ototoxic deafening produced bilaterally symmetrical hearing thresholds in neonatal and adult animals. Electrical activation of the auditory system was confirmed, and all animals were chronically stimulated via adapted clinical CIs. Acoustic compound action potentials (CAPs) were obtained from partially-hearing cochleae, using the CI amplifier. Immunohistochemical analysis allows the effects of deafness and electrical stimulation on cell survival to be studied. Significance. This animal model has applications in EAS research, including investigating the functional interactions between electric and acoustic stimulation, and the development of techniques to maintain residual hearing following cochlear implantation. The ability to record CAPs via the CI has clinical direct relevance for obtaining objective measures of residual hearing.

  17. Expanded polytetrafluoroethylene membrane alters tissue response to implanted Ahmed glaucoma valve.

    PubMed

    DeCroos, Francis Char; Ahmad, Sameer; Kondo, Yuji; Chow, Jessica; Mordes, Daniel; Lee, Maria Regina; Asrani, Sanjay; Allingham, R Rand; Olbrich, Kevin C; Klitzman, Bruce

    2009-07-01

    Long-term intraocular pressure control by glaucoma drainage implants is compromised by the formation of an avascular fibrous capsule that surrounds the glaucoma implant and increases aqueous outflow resistance. It is possible to alter this fibrotic tissue reaction and produce a more vascularized and potentially more permeable capsule around implanted devices by enclosing them in a porous membrane. Ahmed glaucoma implants modified with an outer 5-microm pore size membrane (termed porous retrofitted implant with modified enclosure or PRIME-Ahmed) and unmodified glaucoma implants were implanted into paired rabbit eyes. After 6 weeks, the devices were explanted and subject to histological analysis. A tissue response containing minimal vascularization, negligible immune response, and a thick fibrous capsule surrounded the unmodified Ahmed glaucoma implant. In comparison, the tissue response around the PRIME-Ahmed demonstrated a thinner fibrous capsule (46.4 +/- 10.8 microm for PRIME-Ahmed versus 94.9 +/- 21.2 microm for control, p < 0.001) and was highly vascularized near the tissue-material interface. A prominent chronic inflammatory response was noted as well. Encapsulating the aqueous outflow pathway with a porous membrane produces a more vascular tissue response and thinner fibrous capsule compared with a standard glaucoma implant plate. Enhanced vascularity and a thinner fibrous capsule may reduce aqueous outflow resistance and improve long-term glaucoma implant performance.

  18. Diaphragm pacing system implanted in a patient with ALS.

    PubMed

    Kotan, Dilcan; Kaymak, Kamil; Gündogdu, Aslı Aksoy

    2016-08-10

    The diaphragm pacing system (DPS) is a life quality improving operation in amyotrophic lateral sclerosis (ALS) patients who need mechanical ventilation or have chronic respiratory insufficiency. This procedure is gaining in popularity, and the number of centers implanting diaphragm pacing systems (DPS) is increasing. DPS delays the need for a ventilation machine in the early stages of Amyotrophic lateral sclerosis (ALS) disease. In this case study, we present a young female ALS patient. A DPS was implanted after respiratory insufficiency began. In the one-year follow-up period following her operation, her need for ventilatory support disappeared.

  19. Morphological Correlates of Hearing Loss after Cochlear Implantation and Electro-Acoustic Stimulation in a Hearing-Impaired Guinea Pig Model

    PubMed Central

    Reiss, Lina A.J.; Stark, Gemaine; Nguyen-Huynh, Anh T.; Spear, Kayce A.; Zhang, Hongzheng; Tanaka, Chiemi; Li, Hongzhe

    2016-01-01

    Hybrid or electro-acoustic stimulation (EAS) cochlear implants (CIs) are designed to provide high-frequency electric hearing together with residual low-frequency acoustic hearing. However, 30-50% of EAS CI recipients lose residual hearing after implantation. The objective of this study was to determine the mechanisms of EAS-induced hearing loss in an animal model with high-frequency hearing loss. Guinea pigs were exposed to 24 hours of noise (12-24 kHz at 116 dB) to induce a high-frequency hearing loss. After recovery, two groups of animals were implanted (n=6 per group), with one group receiving chronic acoustic and electric stimulation for 10 weeks, and the other group receiving no stimulation during this time frame. A third group (n=6) was not implanted, but received chronic acoustic stimulation. Auditory brainstem responses were recorded biweekly to monitor changes in hearing. The organ of Corti was immunolabeled with phalloidin, anti-CtBP2, and anti-GluR2 to quantify hair cells, ribbons and post-synaptic receptors. The lateral wall was immunolabeled with phalloidin and lectin to quantify stria vascularis capillary diameters. Bimodal or trimodal diameter distributions were observed; the number and location of peaks were objectively determined using the Aikake Information Criterion and Expectation Maximization algorithm. Noise exposure led to immediate hearing loss at 16-32 kHz for all groups. Cochlear implantation led to additional hearing loss at 4-8 kHz; this hearing loss was negatively and positively correlated with minimum and maximum peaks of the bimodal or trimodal distributions of stria vascularis capillary diameters, respectively. After chronic stimulation, no significant group changes in thresholds were seen; however, elevated thresholds at 1 kHz in implanted, stimulated animals were significantly correlated with decreased presynaptic ribbon and postsynaptic receptor counts. Inner and outer hair cell counts did not differ between groups and were not correlated with threshold shifts at any frequency. As in the previous study in a normal-hearing model, stria vascularis capillary changes were associated with immediate hearing loss after implantation, while little to no hair cell loss was observed even in cochlear regions with threshold shifts as large as 40-50 dB. These findings again support a role of lateral wall blood flow changes, rather than hair cell loss, in hearing loss after surgical trauma, and implicate the endocochlear potential as a factor in implantation-induced hearing loss. Further, the analysis of the hair cell ribbons and post-synaptic receptors suggest that delayed hearing loss may be linked to synapse or peripheral nerve loss due to stimulation excitotoxicity or inflammation. Further research is needed to separate these potential mechanisms of delayed hearing loss. PMID:26087114

  20. Use of implantable telemetry systems for study of cardiovascular phenomena.

    NASA Technical Reports Server (NTRS)

    Sandler, H.; Fryer, T. B.; Westbrook, R. M.; Stone, H. L.

    1972-01-01

    Preliminary observations of cardiovascular function have been made in four chimpanzees using multichannel implantable units. Measurements of right- and left-sided pressures were periodically made in these animals over a four-month period, including continuous observations for selected 24-hour periods. Pressures recorded with animals in an awake, unanesthetized, unrestrained state were much lower than pressures reported for restrained animals in similar situations. Diurnal variations of pressure tended to occur, but were not as clear-cut as those reported to occur for humans. The ability to implant a transmitter chronically and receive useful multichannel information in the chimpanzee encourages the future use of such implant devices as part of the control system for an artificial heart or directly for use in man.

  1. Novel borate glass/chitosan composite as a delivery vehicle for teicoplanin in the treatment of chronic osteomyelitis.

    PubMed

    Jia, Wei-Tao; Zhang, Xin; Luo, Shi-Hua; Liu, Xin; Huang, Wen-Hai; Rahaman, Mohamed N; Day, Delbert E; Zhang, Chang-Qing; Xie, Zong-Ping; Wang, Jian-Qiang

    2010-03-01

    Composite materials composed of borate bioactive glass and chitosan (designated BGC) were investigated in vitro and in vivo as a new delivery system for teicoplanin in the treatment of chronic osteomyelitis induced by methicillin-resistant Staphylococcus aureus (MRSA). In vitro, the release of teicoplanin from BGC pellets into phosphate-buffered saline (PBS), as well as its antibacterial activity, were determined. The compressive strength of the pellets was measured after specific immersion times, and the structure of the pellets was characterized using scanning electron microscopy and X-ray diffraction. In vivo, the tibial cavity of New Zealand White rabbits was injected with MRSA strain to induce chronic osteomyelitis, treated by debridement after 4weeks, implanted with teicoplanin-loaded BGC pellets (designated TBGC) or BGC pellets, or injected intravenously with teicoplanin. After 12weeks' implantation, the efficacy of the TBGC pellets for treating osteomyelitis was evaluated using hematological, radiological, microbiological and histological techniques. When immersed in PBS, the TBGC pellets provided a sustained release of teicoplanin, while the surface of the pellets was converted to hydroxyapatite (HA). In vivo, the best therapeutic effect was observed in animals implanted with TBGC pellets, resulting in significantly lower radiological and histological scores, a lower positive rate of MRSA culture, and an excellent bone defect repair, without local or systemic side effects. The results indicate that TBGC pellets are effective in treating chronic osteomyelitis by providing a sustained release of teicoplanin, in addition to participating in bone regeneration. Copyright 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  2. Telemetry and Telestimulation via Implanted Devices Necessary in Long-Term Experiments Using Conscious Untethered Animals for the Development of New Medical Treatments

    NASA Astrophysics Data System (ADS)

    Sugimachi, Masaru; Kawada, Toru; Uemura, Kazunori

    Effective countermeasures against explosive increase in healthcare expenditures are urgently needed. A paradigm shift in healthcare is called for, and academics and governments worldwide are working hard on the application of information and communication technologies (ICT) as a feasible and effective measure for reducing medical cost. The more prevalent the disease and the easier disease outcome can be improved, the more efficient is medical ICT in reducing healthcare cost. Hypertension and diabetes mellitus are such examples. Chronic heart failure is another disease in which patients may benefit from ICT-based medical practice. It is conceivable that daily monitoring of hemodynamics together with appropriate treatments may obviate the expensive hospitalization. ICT potentially permit continuous monitoring with wearable or implantable medical devices. ICT may also help accelerate the development of new therapeutic devices. Traditionally effectiveness of treatments is sequentially examined by sacrificing a number of animals at a given time point. These inefficient and inaccurate methods can be replaced by applying ICT to the devices used in chronic animal experiments. These devices allow researchers to obtain biosignals and images from live animals without killing them. They include implantable telemetric devices, implantable telestimulation devices, and imaging devices. Implanted rather than wired monitoring and stimulation devices permit experiments to be conducted under even more physiological conditions, i.e., untethered, free-moving states. Wireless communication and ICT are indispensible technologies for the development of such telemetric and telestimulation devices.

  3. Chronic neuromuscular electrical stimulation of paralyzed hindlimbs in a rodent model.

    PubMed

    Jung, Ranu; Ichihara, Kazuhiko; Venkatasubramanian, Ganapriya; Abbas, James J

    2009-10-15

    Neuromuscular electrical stimulation (NMES) can be used to activate paralyzed or paretic muscles to generate functional or therapeutic movements. The goal of this research was to develop a rodent model of NMES-assisted movement therapy after spinal cord injury (SCI) that will enable investigation of mechanisms of NMES-induced plasticity, from the molecular to systems level. Development of the model requires accurate mapping of electrode and muscle stimulation sites, the capability to selectively activate muscles to produce graded contractions of sufficient strength, stable anchoring of the implanted electrode within the muscles and stable performance with functional reliability over several weeks of the therapy window. Custom designed electrodes were implanted chronically in hindlimb muscles of spinal cord transected rats. Mechanical and electrical stability of electrodes and the ability to achieve appropriate muscle recruitment and joint angle excursion were assessed by characterizing the strength duration curves, isometric torque recruitment curves and kinematics of joint angle excursion over 6-8 weeks post implantation. Results indicate that the custom designed electrodes and implantation techniques provided sufficient anchoring and produced stable and reliable recruitment of muscles both in the absence of daily NMES (for 8 weeks) as well as with daily NMES that is initiated 3 weeks post implantation (for 6 weeks). The completed work establishes a rodent model that can be used to investigate mechanisms of neuroplasticity that underlie NMES-based movement therapy after spinal cord injury and to optimize the timing of its delivery.

  4. Plasma-assisted atomic layer deposition of Al(2)O(3) and parylene C bi-layer encapsulation for chronic implantable electronics.

    PubMed

    Xie, Xianzong; Rieth, Loren; Merugu, Srinivas; Tathireddy, Prashant; Solzbacher, Florian

    2012-08-27

    Encapsulation of biomedical implants with complex three dimensional geometries is one of the greatest challenges achieving long-term functionality and stability. This report presents an encapsulation scheme that combines Al(2)O(3) by atomic layer deposition with parylene C for implantable electronic systems. The Al(2)O(3)-parylene C bi-layer was used to encapsulate interdigitated electrodes, which were tested invitro by soak testing in phosphate buffered saline solution at body temperature (37 °C) and elevated temperatures (57 °C and 67 °C) for accelerated lifetime testing up to 5 months. Leakage current and electrochemical impedance spectroscopy were measured for evaluating the integrity and insulation performance of the coating. Leakage current was stably about 15 pA at 5 V dc, and impedance was constantly about 3.5 MΩ at 1 kHz by using electrochemical impedance spectroscopy for samples under 67 °C about 5 months (approximately equivalent to 40 months at 37 °C). Alumina and parylene coating lasted at least 3 times longer than parylene coated samples tested at 80 °C. The excellent insulation performance of the encapsulation shows its potential usefulness for chronic implants.

  5. Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring.

    PubMed

    Mueller, Matthias; de la Oliva, Natalia; Del Valle, Jaume; Delgado-Martínez, Ignacio; Navarro, Xavier; Stieglitz, Thomas

    2017-12-01

    Interfacing the peripheral nervous system can be performed with a large variety of electrode arrays. However, stimulating and recording a nerve while having a reasonable amount of channels limits the number of available systems. Translational research towards human clinical trial requires device safety and biocompatibility but would benefit from design flexibility in the development process to individualize probes. We selected established medical grade implant materials like precious metals and Parylene C to develop a rapid prototyping process for novel intrafascicular electrode arrays using a picosecond laser structuring. A design for a rodent animal model was developed in conjunction with an intrafascicular implantation strategy. Electrode characterization and optimization was performed first in saline solution in vitro before performance and biocompatibility were validated in sciatic nerves of rats in chronic implantation. The novel fabrication process proved to be suitable for prototyping and building intrafascicular electrode arrays. Electrochemical properties of the electrode sites were enhanced and tested for long-term stability. Chronic implantation in the sciatic nerve of rats showed good biocompatibility, selectivity and stable stimulation thresholds. Established medical grade materials can be used for intrafascicular nerve electrode arrays when laser structuring defines structure size in the micro-scale. Design flexibility reduces re-design cycle time and material certificates are beneficial support for safety studies on the way to clinical trials.

  6. Obturator Neuromodulation with Laparoscopic Placement of an Obturator Lead for the Treatment of Intractable Opioid Dependent Chronic Pelvic Pain due to Obturator Neuralgia.

    PubMed

    Marvel, Richard P

    2018-05-12

    Chronic pelvic pain(CPP) is a common condition in women that can have a devastating effect on quality of life. Some of the most severe forms of CPP are related to peripheral nerve injuries causing persistent neuropathic pain. This is a case of a young woman with severe opioid dependent chronic pelvic and right groin pain due to obturator neuralgia. She had failed a multitude of treatments including multiple medications, manual physical therapy, nerve blocks, surgical neurolysis and spinal cord stimulation without significant benefit. She underwent a trial of peripheral neuromodulation of the obturator nerve with laparoscopic placement of a quadripolar lead. During the 6-day trial she had almost complete relief of her pain; therefore, she underwent permanent implantation of an intermittent pulse generator. Over the next 6 months she was completely weaned completely off her chronic opioids. At 23 months post implantation, she had essentially no pain and is no longer on any analgesic, antidepressant or membrane stabilizing medications. Peripheral Neuromodulation has the potential to alleviate pain and significantly improve quality of life in women with longstanding neuropathic chronic pelvic pain who have failed multimodal conservative therapy. Copyright © 2018. Published by Elsevier Inc.

  7. Customizable cap implants for neurophysiological experimentation.

    PubMed

    Blonde, Jackson D; Roussy, Megan; Luna, Rogelio; Mahmoudian, Borna; Gulli, Roberto A; Barker, Kevin C; Lau, Jonathan C; Martinez-Trujillo, Julio C

    2018-04-22

    Several primate neurophysiology laboratories have adopted acrylic-free, custom-fit cranial implants. These implants are often comprised of titanium or plastic polymers, such as polyether ether ketone (PEEK). Titanium is favored for its mechanical strength and osseointegrative properties whereas PEEK is notable for its lightweight, machinability, and MRI compatibility. Recent titanium/PEEK implants have proven to be effective in minimizing infection and implant failure, thereby prolonging experiments and optimizing the scientific contribution of a single primate. We created novel, customizable PEEK 'cap' implants that contour to the primate's skull. The implants were created using MRI and/or CT data, SolidWorks software and CNC-machining. Three rhesus macaques were implanted with a PEEK cap implant. Head fixation and chronic recordings were successfully performed. Improvements in design and surgical technique solved issues of granulation tissue formation and headpost screw breakage. Primate cranial implants have traditionally been fastened to the skull using acrylic and anchor screws. This technique is prone to skin recession, infection, and implant failure. More recent methods have used imaging data to create custom-fit titanium/PEEK implants with radially extending feet or vertical columns. Compared to our design, these implants are more surgically invasive over time, have less force distribution, and/or do not optimize the utilizable surface area of the skull. Our PEEK cap implants served as an effective and affordable means to perform electrophysiological experimentation while reducing surgical invasiveness, providing increased strength, and optimizing useful surface area. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  8. An abdominal active can defibrillator may facilitate a successful generator change when a lead failure is present.

    PubMed

    Solomon, A J; Moubarak, J B; Drood, J M; Tracy, C M; Karasik, P E

    1999-10-01

    Defibrillator generator changes are frequently performed on patients with an implantable cardioverter defibrillator in an abdominal pocket. These patients usually have epicardial patches or older endocardial lead systems. At the time of a defibrillator generator change defibrillation may be unsuccessful as a result of lead failure. We tested the hypothesis that an active can defibrillator implanted in the abdominal pocket could replace a non-functioning endocardial lead or epicardial patch. An abdominal defibrillator generator change was performed in 10 patients, (mean age = 67 +/- 13 years, nine men). Initially, a defibrillation threshold (DFT) was obtained using a passive defibrillator and the chronic endocardial or epicardial lead system. DFTs were then performed using an active can emulator and one chronic lead to simulate endocardial or epicardial lead failure. We tested 30 lead configurations (nine endocardial and 21 epicardial). Although a DFT of 7.3 +/- 4.2 joules was obtained with the intact chronic lead system, the active can emulator and one endocardial or epicardial lead still yielded an acceptable DFT of 19.9 +/- 6.1 joules. In addition, a successful implant (DFT < or = 24 joules) could have been accomplished in 28 of 30 (93%) lead configurations. An active can defibrillator in an abdominal pocket may allow for a successful generator change in patients with defibrillator lead malfunction. This would be simpler than abandoning the abdominal implant and moving to a new pectoral device and lead or tunnelling a new endocardial electrode. However, loss of defibrillation capability with a particular complex lead may be a warning of impending loss of other functions (eg. sensing and/or pacing).

  9. [Port device central venous access in children with chronic renal disease--personal experience].

    PubMed

    Szczepańska, Maria; Szprynger, Krystyna; Stoksik, Piotr; Morawiec-Knysak, Aurelia; Adamczyk, Piotr; Ziora, Katarzyna; Oswiecimska, Joanna

    2006-01-01

    The application of central venous lines in children has been widely accepted in the case of pediatric cancer treatment. This is of particular importance when the treatment must be continued during the long period of time. The indication to long-term application of central venous lines became significantly frequent within last years. They are necessary in the treatment of chronic pediatric patients, in whom the central venous line allows continuous access for medication, parenteral rehydration, nutrition and frequent blood sampling. In the current study authors present their experience in subcutaneous port devices application in children with kidney disease. The case history data obtained from 8 children were retrospectively analysed. In these children subcutaneous port devices were applied for mean 26.7 months (totally 9 port devices). The mean age at the time of implantation was 2.2 years, and the mean body weight--10.6 kg. Peripheral venous access in all children was bad. In one child during the time of implantation the hematoma of coli and chest was present. Infectious complications connected with implanted port device were not detected. Thrombotic complications were present in 6 children with chronic renal failure--in 5 the lumen of port device has been successfully recanalysed, in 3 cases even several times. In 1 child the thrombus on the tip of central venous line was detected. In 2 children the removal of port device was necessary because of breakage of venous line and in the second case because of port device thrombosis. Two children died with functioning port device. The cause of death was not connected with implanted port device. The application of subcutaneous port devices definitely improved the comfort of treatment but was significantly associated with thrombotic complications. Infectious complications were not detected as compared to hematological group of patients.

  10. * Murine Model of Progressive Orthopedic Wear Particle-Induced Chronic Inflammation and Osteolysis.

    PubMed

    Pajarinen, Jukka; Nabeshima, Akira; Lin, Tzu-Hua; Sato, Taishi; Gibon, Emmanuel; Jämsen, Eemeli; Lu, Laura; Nathan, Karthik; Yao, Zhenyu; Goodman, Stuart B

    2017-12-01

    Periprosthetic osteolysis and subsequent aseptic loosening of total joint replacements are driven by byproducts of wear released from the implant. Wear particles cause macrophage-mediated inflammation that culminates with periprosthetic bone loss. Most current animal models of particle-induced osteolysis are based on the acute inflammatory reaction induced by wear debris, which is distinct from the slowly progressive clinical scenario. To address this limitation, we previously developed a murine model of periprosthetic osteolysis that is based on slow continuous delivery of wear particles into the murine distal femur over a period of 4 weeks. The particle delivery was accomplished by using subcutaneously implanted osmotic pumps and tubing, and a hollow titanium rod press-fit into the distal femur. In this study, we report a modification of our prior model in which particle delivery is extended to 8 weeks to better mimic the progressive development of periprosthetic osteolysis and allow the assessment of interventions in a setting where the chronic particle-induced osteolysis is already present at the initiation of the treatment. Compared to 4-week samples, extending the particle delivery to 8 weeks significantly exacerbated the local bone loss observed with μCT and the amount of both peri-implant F4/80 + macrophages and tartrate-resistant acid phosphatase-positive osteoclasts detected with immunohistochemical and histochemical staining. Furthermore, systemic recruitment of reporter macrophages to peri-implant tissues observed with bioluminescence imaging continued even at the later stages of particle-induced inflammation. This modified model system could provide new insights into the mechanisms of chronic inflammatory bone loss and be particularly useful in assessing the efficacy of treatments in a setting that resembles the clinical scenario of developing periprosthetic osteolysis more closely than currently existing model systems.

  11. Retrospective analysis of the financial break-even point for intrathecal morphine pump use in Korea.

    PubMed

    Kim, Eun Kyoung; Shin, Ji Yeon; Castañeda, Anyela Marcela; Lee, Seung Jae; Yoon, Hyun Kyu; Kim, Yong Chul; Moon, Jee Youn

    2017-10-01

    The high cost of intrathecal morphine pump (ITMP) implantation may be the main obstacle to its use. Since July 2014, the Korean national health insurance (NHI) program began paying 50% of the ITMP implantation cost in select refractory chronic pain patients. The aims of this study were to investigate the financial break-even point and patients' satisfaction in patients with ITMP treatment after the initiation of the NHI reimbursement. We collected data retrospectively or via direct phone calls to patients who underwent ITMP implantation at a single university-based tertiary hospital between July 2014 and May 2016. Pain severity, changes in the morphine equivalent daily dosage (MEDD), any adverse events, and patients' satisfaction were determined. We calculated the financial break-even point of ITMP implantation via investigating the patient's actual medical costs and insurance information. During the studied period, 23 patients received ITMP implantation, and 20 patients were included in our study. Scores on an 11-point numeric rating scale (NRS) for pain were significantly reduced compared to the baseline value ( P < 0.001). The MEDD before ITMP implantation was 0.59 [IQR: 0.55-0.82]. The total MEDD increased steadily to 0.77 [IQR: 0.53-1.08] at 1 year, which was 126% of the baseline ( P < 0.001). More than a half (60%) responded that the ITMP therapy was somewhat satisfying. The financial break-even point was 28 months for ITMP treatment after the NHI reimbursement policy. ITMP provided effective chronic pain management with improved satisfaction and reasonable financial break-even point of 28 months with 50% financial coverage by NHI program.

  12. Associations Between Pre-Implant Psychosocial Factors and Spinal Cord Stimulation Outcome: Evaluation Using the MMPI-2-RF.

    PubMed

    Block, Andrew R; Marek, Ryan J; Ben-Porath, Yossef S; Kukal, Deborah

    2017-01-01

    Spinal cord stimulation (SCS) has variable effectiveness in controlling chronic pain. Previous research has demonstrated that psychosocial factors are associated with diminished results of SCS. The objective of this investigation is to examine associations between pre-implant psychological functioning as measured by the Minnesota Multiphasic Personality Inventory-2-Restructured Form (MMPI-2-RF) and SCS outcomes. SCS candidates at two sites (total N = 319) completed the MMPI-2-RF and measures of pain, emotional distress, and functional ability as part of a pre-implant psychological evaluation. At an average of 5 months post-implant, patients completed the measures of pain and emotional distress a second time. Poorer SCS outcomes and poorer patient satisfaction were associated with higher pre-implant MMPI-2-RF scores on scales used to assess emotional dysfunction, somatic/cognitive complaints, and interpersonal problems. Ways through which pre-implant psychological evaluations of spinal cord stimulator candidates can be informed by MMPI-2-RF findings are discussed. © The Author(s) 2015.

  13. Modified endoscopic medial maxillectomy for zygomatic implant salvage

    PubMed Central

    Tajudeen, Bobby A.; Adappa, Nithin D.; Palmer, James N.

    2016-01-01

    Objectives: Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. Methods: We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. Results: The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. Conclusion: We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant. PMID:28107147

  14. Active Microelectronic Neurosensor Arrays for Implantable Brain Communication Interfaces

    PubMed Central

    Song, Y.-K.; Borton, D. A.; Park, S.; Patterson, W. R.; Bull, C. W.; Laiwalla, F.; Mislow, J.; Simeral, J. D.; Donoghue, J. P.; Nurmikko, A. V.

    2010-01-01

    We have built a wireless implantable microelectronic device for transmitting cortical signals transcutaneously. The device is aimed at interfacing a microelectrode array cortical to an external computer for neural control applications. Our implantable microsystem enables presently 16-channel broadband neural recording in a non-human primate brain by converting these signals to a digital stream of infrared light pulses for transmission through the skin. The implantable unit employs a flexible polymer substrate onto which we have integrated ultra-low power amplification with analog multiplexing, an analog-to-digital converter, a low power digital controller chip, and infrared telemetry. The scalable 16-channel microsystem can employ any of several modalities of power supply, including via radio frequency by induction, or infrared light via a photovoltaic converter. As of today, the implant has been tested as a sub-chronic unit in non-human primates (~ 1 month), yielding robust spike and broadband neural data on all available channels. PMID:19502132

  15. Fluocinolone acetonide implant (Retisert) for chronic cystoid macular edema in two patients with AIDS and a history of cytomegalovirus retinitis.

    PubMed

    Hu, Jianmin; Coassin, Marco; Stewart, Jay M

    2011-06-01

    To report the authors' experience using fluocinolone acetonide (Retisert) to treat cystoid macular edema (CME) resulting from immune recovery uveitis (IRU) in 2 acquired immunodeficiency syndrome (AIDS) patients with a history of cytomegalovirus (CMV) retinitis. Interventional case series. Medical records were reviewed of 2 patients who received Retisert implantation in 3 eyes for IRU-associated inflammation and CME. Suppression of CMV disease was achieved with oral medication in one patient and with simultaneous implantation of a ganciclovir implant in the other patient. After Retisert implantation in 3 eyes in AIDS patients on HAART, improvement in CME was seen in 2 eyes. No CMV reactivation was detected during the several-month follow-up period. Retisert may be an effective treatment for CME in AIDS patients with IRU reactivation and a history of CMV retinitis.

  16. Adequate antiplatelet regimen in patients on chronic anti-vitamin K treatment undergoing percutaneous coronary intervention

    PubMed Central

    Brugaletta, Salvatore; Martin-Yuste, Victoria; Ferreira-González, Ignacio; Cola, Clarissa; Alvarez-Contreras, Luis; Antonio, Marta De; Garcia-Moll, Xavier; García-Picart, Joan; Martí, Vicens; Balcells-Iranzo, Jordi; Sabaté, Manel

    2011-01-01

    AIM: To investigate the impact of dual antiplatelet therapy (DAT) in patients on anti-vitamin K (AVK) regimen requiring percutaneous coronary intervention (PCI). METHODS: Between February 2006 and February 2008, 138 consecutive patients under chronic AVK treatment were enrolled in this registry. Of them, 122 received bare metal stent implantation and 16 received drug eluting stent implantation. The duration of DAT, on top of AVK treatment, was decided at the discretion of the clinician. Adequate duration of DAT was defined according to type of stent implanted and to its clinical indication. RESULTS: The baseline clinical characteristics of patients reflect their high risk, with high incidence of comorbid conditions (Charlson score ≥ 3 in 89% of the patients). At a mean follow-up of 17 ± 11 mo, 22.9% of patients developed a major adverse cardiac event (MACE): 12.6% died from cardiovascular disease and almost 6% had an acute myocardial infarction. Major hemorrhagic events were observed in 7.4%. Adequate DAT was obtained in only 44% of patients. In the multivariate analysis, no adequate DAT and Charlson score were the only independent predictors of MACE (both P = 0.02). CONCLUSION: Patients on chronic AVK therapy represent a high risk population and suffer from a high MACE rate after PCI. An adequate DAT regimen and absence of comorbid conditions are strongly associated with better clinical outcomes. PMID:22125672

  17. The Physics of Ultrabroadband Frequency Comb Generation and Optimized Combs for Measurements in Fundamental Physics

    DTIC Science & Technology

    2016-07-02

    great potential of chalcogenide microwires for applications in the mid-IR ranging from absorption spectroscopy to entangled photon pairs generation...modulation instability) gain. Stochastic nonlinear Schrödinger equation simulations were shown to be in very good agreement with experiment. This...as the seed coherence decreases. Stochastic nonlinear Schrödinger equation simulations of spectral and noise properties are in excellent agreement with

  18. The foreign body response: at the interface of surgery and bioengineering.

    PubMed

    Major, Melanie R; Wong, Victor W; Nelson, Emily R; Longaker, Michael T; Gurtner, Geoffrey C

    2015-05-01

    The surgical implantation of materials and devices has dramatically increased over the past decade. This trend is expected to continue with the broadening application of biomaterials and rapid expansion of aging populations. One major factor that limits the potential of implantable materials and devices is the foreign body response, an immunologic reaction characterized by chronic inflammation, foreign body giant cell formation, and fibrotic capsule formation. The English literature on the foreign body response to implanted materials and devices is reviewed. Fibrotic encapsulation can cause device malfunction and dramatically limit the function of an implanted medical device or material. Basic science studies suggest a role for immune and inflammatory pathways at the implant-host interface that drive the foreign body response. Current strategies that aim to modulate the host response and improve construct biocompatibility appear promising. This review article summarizes recent basic science, preclinical, and clinicopathologic studies examining the mechanisms driving the foreign body response, with particular focus on breast implants and synthetic meshes. Understanding these molecular and cellular mechanisms will be critical for achieving the full potential of implanted biomaterials to restore human tissues and organs.

  19. Staged Hard and Soft Tissue Reconstruction Followed by Implant Supported Restoration in the Aesthetic Zone: A Case Report.

    PubMed

    Parthasarathy, Harinath; Ramachandran, Lakshmi; Tadepalli, Anupama; Ponnaiyan, Deepa

    2017-04-01

    Alveolar ridge deficiency is a common clinical consequence following tooth loss due to chronic periodontitis complicating ideal implant placement. Advanced hard and soft tissue augmentation procedures have been developed in the recent past with predictable clinical outcomes. A male patient presented with a Grade III mobile upper right central incisor associated with advanced bone loss and soft tissue deficit. Following extraction of tooth #11, socket augmentation was done using an autogenous cortico-cancellous block graft and subsequent soft tissue augmentation was done with palatal connective tissue graft. At the end of six months, a tapered self tapping implant fixture was placed with adequate primary stability and after eight weeks, second stage implant surgery was done with the Misch technique in order to recreate papillae and the implant was prosthetically restored. The alveolar ridge was adequately recontoured following the staged surgical protocol. The implant was well integrated at the end of 15 months. Execution of sequential surgical procedures in a highly deficient edentulous site made it possible to achieve of optimal pink and white aesthetics with stable implant supported fixed prosthesis.

  20. Superelasticity by reversible variant reorientation in a Ni-Mn-Ga microwire with bamboo grains

    DOE PAGES

    Wang, Z. L.; Zheng, P.; Nie, Z. H.; ...

    2015-08-26

    The link between microstructure and mechanical properties is investigated for a superelastic Ni–Mn–Ga microwire with 226 μm diameter, created by solidification via the Taylor method. The wire, which consists of bamboo grains with tetragonal martensite matrix and coarse γ precipitates, exhibits fully reversible superelastic behavior up to 4% tensile strain. Upon multiple tensile load–unload cycles, reproducible stress fluctuations of ~3 MPa are measured on the loading superelastic stress plateau of ~50 MPa. During cycles at various temperatures spanning -70 to 55 °C, the plateau stress decreases from 58 to 48 MPa near linearly with increasing temperature. Based on in situmore » synchrotron X-ray diffraction measurements, we conclude that this superelastic behavior is due to reversible martensite variants reorientation (i.e., reversible twinning) with lattice rotation of ~13°. The reproducible stress plateau fluctuations are assigned to reversible twinning at well-defined locations along the wire. The strain recovery during unloading is attributed to reverse twinning, driven by the internal stress generated on loading between the elastic γ precipitates and the twinning martensite matrix. Lastly, the temperature dependence of the twining stress on loading is related to the change in tetragonality of the martensite, as measured by X-ray diffraction.« less

  1. Helical shell-domain structure in laser-annealed Co-based amorphous microwires analyzed by giant magnetoimpedance

    NASA Astrophysics Data System (ADS)

    Ahn, S. J.; Rheem, Y. W.; Yoon, S. S.; Lee, B. S.; Kim, C. G.; Kim, C. O.

    2003-04-01

    A commercial glass-covered, Co-based amorphous microwire (Co 67Fe 3.8Ni 1.4B 11.5Si 14.6Mo 1.7) is etched in order to remove its glass cover in a 60.51% hydrofluoric acid solution, and annealed in air by illuminating with a pulsed Nd:YAG laser beams with an energy E of 48 mJ/pulse. Giant magnetoimpedance (GMI) profiles at a frequency f are measured as function of the angle θ of the external field, H, with respect to the wire axis. The sign of the H values at the peak of the GMI profiles for f=100 kHz and at the dip of the GMI profiles for f=10 MHz, Hp and Hd, respectively, change at θ=85-90°, reflecting that the tilt angle of the helical domains is between 0° and 5° from the circular direction for the as-etched samples. The variations of Hp and Hd with θ for the sample with E=48 mJ/pulse and Ha=20 Oe show a change in sign of Hp and Hd at θ=90-100°, reflecting that the tilt angle of the helical domains is decreased by about -10° compared to that of the as-etched sample.

  2. Size-dependent physicochemical and mechanical interactions in battery paste anodes of Si-microwires revealed by Fast-Fourier-Transform Impedance Spectroscopy

    NASA Astrophysics Data System (ADS)

    Hansen, Sandra; Quiroga-González, Enrique; Carstensen, Jürgen; Adelung, Rainer; Föll, Helmut

    2017-05-01

    Perfectly aligned silicon microwire arrays show exceptionally high cycling stability with record setting (high) areal capacities of 4.25 mAh cm-2. Those wires have a special, modified length and thickness in order to perform this good. Geometry and sizes are the most important parameters of an anode to obtain batteries with high cycling stability without irreversible losses. The wires are prepared with a unique etching fabrication method, which allows to fabricate wires of very precise sizes. In order to investigate how good randomly oriented silicon wires perform in contrast to the perfect order of the array, the wires are embedded in a paste. This study reveals the fundamental correlation between geometry, mechanics and charge transfer kinetics of silicon electrodes. Using a suitable RC equivalent circuit allows to evaluate data from cyclic voltammetry and simultaneous FFT-Impedance Spectroscopy (FFT-IS), yielding in time-resolved resistances, time constants, and their direct correlation to the phase transformations. The change of the resistances during lithiation and delithiation correlates to kinetics and charge transfer mechanisms. This study demonstrates how the mechanical and physiochemical interactions at the silicon/paste interface inside the paste electrodes lead to void formation around silicon and with it to material loss and capacity fading.

  3. An Improved Medium for Growing Staphylococcus aureus Biofilm

    DTIC Science & Technology

    2012-04-19

    implantitis, chronic wound infections , chronic rhinosinusitis, endocarditis , and ocular infections (Archer et al., 2011). In addition, emerging evidence...causes of human bacterial infections , Staphylococcus aureus, a gram positive organism, is a ubiquitous oppor tunistic pathogen that commonly colonizes...resistant to antibiotic therapy. It has been shown that S. aureus biofilms are involved in oste omyelitis; indwelling medical device infections ; and peri

  4. Self-powered implantable electronic-skin for in situ analysis of urea/uric-acid in body fluids and the potential applications in real-time kidney-disease diagnosis.

    PubMed

    Yang, Wenyan; Han, Wuxiao; Gao, Huiling; Zhang, Linlin; Wang, Shuai; Xing, Lili; Zhang, Yan; Xue, Xinyu

    2018-01-25

    As the concentration of different biomarkers in human body fluids are an important parameter of chronic disease, wearable biosensors for in situ analysis of body fluids with high sensitivity, real-time detection, flexibility and biocompatibility have significant potential therapeutic applications. In this paper, a flexible self-powered implantable electronic-skin (e-skin) for in situ body fluids analysis (urea/uric-acid) as a real-time kidney-disease diagnoser has been proposed based on the piezo-enzymatic-reaction coupling process of ZnO nanowire arrays. It can convert the mechanical energy of body movements into a piezoelectric impulse, and the outputting piezoelectric signal contains the urea/uric-acid concentration information in body fluids. This piezoelectric-biosensing process does not need an external electricity supply or battery. The e-skin was implanted under the abdominal skin of a mouse and provided in situ analysis of the kidney-disease parameters. These results provide a new approach for developing a self-powered in situ body fluids-analysis technique for chronic-disease diagnosis.

  5. The biological response to orthopedic implants for joint replacement. II: Polyethylene, ceramics, PMMA, and the foreign body reaction

    PubMed Central

    Gibon, Emmanuel; Córdova, Luis A.; Lu, Laura; Lin, Tzu-Hua; Yao, Zhenyu; Hamadouche, Moussa; Goodman, Stuart B.

    2017-01-01

    Novel evidence-based prosthetic designs and biomaterials facilitate the performance of highly successful joint replacement (JR) procedures. To achieve this goal, constructs must be durable, biomechanically sound, and avoid adverse local tissue reactions. Different biomaterials such as metals and their alloys, polymers, ceramics, and composites are currently used for JR implants. This review focuses on (1) the biological response to the different biomaterials used for TJR and (2) the chronic inflammatory and foreign-body response induced by byproducts of these biomaterials. A homeostatic state of bone and surrounding soft tissue with current biomaterials for JR can be achieved with mechanically stable, infection free and intact (as opposed to the release of particulate or ionic byproducts) implants. Adverse local tissue reactions (an acute/chronic inflammatory reaction, periprosthetic osteolysis, loosening and subsequent mechanical failure) may evolve when the latter conditions are not met. This article (Part 2 of 2) summarizes the biological response to the non-metallic materials commonly used for joint replacement including polyethylene, ceramics, and polymethylmethacrylate (PMMA), as well as the foreign body reaction to byproducts of these materials. PMID:27080740

  6. Heterogeneity of serum activities of matrix metalloproteinases in chronic endometritis.

    PubMed

    Sukhikh, G T; Soboleva, G M; Silantyeva, E S; Shagerbieva, E A; Serov, V N

    2007-04-01

    Matrix metalloproteinases belong to the key molecules of tissue remodeling involved in physiological and pathological processes of the female reproductive system. Adequate levels of their expression in the endometrium are essential for effective implantation and uneventful pregnancy. Chronic inflammatory process in the endometrium is associated with low tissue expression of metalloproteinase-9. Histologically verified chronic endometritis is associated with low serum activities of metalloproteinases 2 and 9, which are restored after combined etiotropic therapy. We measured serum levels of metalloproteinases in patients with chronic endometritis concomitant with sterility and its changes during the first days after magnetotherapy.

  7. Implanted Miniaturized Antenna for Brain Computer Interface Applications: Analysis and Design

    PubMed Central

    Zhao, Yujuan; Rennaker, Robert L.; Hutchens, Chris; Ibrahim, Tamer S.

    2014-01-01

    Implantable Brain Computer Interfaces (BCIs) are designed to provide real-time control signals for prosthetic devices, study brain function, and/or restore sensory information lost as a result of injury or disease. Using Radio Frequency (RF) to wirelessly power a BCI could widely extend the number of applications and increase chronic in-vivo viability. However, due to the limited size and the electromagnetic loss of human brain tissues, implanted miniaturized antennas suffer low radiation efficiency. This work presents simulations, analysis and designs of implanted antennas for a wireless implantable RF-powered brain computer interface application. The results show that thin (on the order of 100 micrometers thickness) biocompatible insulating layers can significantly impact the antenna performance. The proper selection of the dielectric properties of the biocompatible insulating layers and the implantation position inside human brain tissues can facilitate efficient RF power reception by the implanted antenna. While the results show that the effects of the human head shape on implanted antenna performance is somewhat negligible, the constitutive properties of the brain tissues surrounding the implanted antenna can significantly impact the electrical characteristics (input impedance, and operational frequency) of the implanted antenna. Three miniaturized antenna designs are simulated and demonstrate that maximum RF power of up to 1.8 milli-Watts can be received at 2 GHz when the antenna implanted around the dura, without violating the Specific Absorption Rate (SAR) limits. PMID:25079941

  8. Behavioral determination of stimulus pair discrimination of auditory acoustic and electrical stimuli using a classical conditioning and heart-rate approach.

    PubMed

    Morgan, Simeon J; Paolini, Antonio G

    2012-06-06

    Acute animal preparations have been used in research prospectively investigating electrode designs and stimulation techniques for integration into neural auditory prostheses, such as auditory brainstem implants and auditory midbrain implants. While acute experiments can give initial insight to the effectiveness of the implant, testing the chronically implanted and awake animals provides the advantage of examining the psychophysical properties of the sensations induced using implanted devices. Several techniques such as reward-based operant conditioning, conditioned avoidance, or classical fear conditioning have been used to provide behavioral confirmation of detection of a relevant stimulus attribute. Selection of a technique involves balancing aspects including time efficiency (often poor in reward-based approaches), the ability to test a plurality of stimulus attributes simultaneously (limited in conditioned avoidance), and measure reliability of repeated stimuli (a potential constraint when physiological measures are employed). Here, a classical fear conditioning behavioral method is presented which may be used to simultaneously test both detection of a stimulus, and discrimination between two stimuli. Heart-rate is used as a measure of fear response, which reduces or eliminates the requirement for time-consuming video coding for freeze behaviour or other such measures (although such measures could be included to provide convergent evidence). Animals were conditioned using these techniques in three 2-hour conditioning sessions, each providing 48 stimulus trials. Subsequent 48-trial testing sessions were then used to test for detection of each stimulus in presented pairs, and test discrimination between the member stimuli of each pair. This behavioral method is presented in the context of its utilisation in auditory prosthetic research. The implantation of electrocardiogram telemetry devices is shown. Subsequent implantation of brain electrodes into the Cochlear Nucleus, guided by the monitoring of neural responses to acoustic stimuli, and the fixation of the electrode into place for chronic use is likewise shown.

  9. Histopathological reaction over prosthesis surface covered with silicone and polyurethane foam implanted in rats.

    PubMed

    Wagenführ-Júnior, Jorge; Ribas Filho, Jurandir Marcondes; Nascimento, Marcelo Mazza do; Ribas, Fernanda Marcondes; Wanka, Marcus Vinícius; Godoi, Andressa de Lima

    2012-12-01

    To evaluate whether polyurethane foam leads more intense foreign-body reaction than silicone foam. To compare the vascularization of the capsules surrounding the foam implants. To investigate if the capsule of polyurethane foam implanted has greater amount of collagen than that of silicone foam. Sixty-four young male Wistar rats were allocated into two groups: polyurethane foam and silicone foam. Subcutaneous discs were implanted into the dorsum of the animals in both groups. The capsules were assessed 28 days, two months, three months and six months postoperatively. Microscopic analysis with H&E stain was performed to evaluate the acute and chronic inflammatory process, foreign-body reaction and neovascularization. The analysis with picrosirius red was performed using the ImageProPlus software, to measure the number of vessels and collagen types I and III. There were no statistical differences between the two groups regarding the acute and chronic inflammatory processes. All rats from the polyurethane group, in all times, exhibited moderate or intense foreign-body reaction, with statistic significant difference (p=0.046) when compared with the silicone group, in which the reaction was either mild or nonexistent at two months. Vascular proliferation was significantly different between the groups at 28 days (p=0.0002), with the polyurethane group displaying greater neovascularization with H&E stain. Similar results were obtained with picrosirius red, which revealed in the polyurethane group a much greater number of vessels than in the silicone group (p=0.001). The collagen area was larger in the polyurethane group, significantly at 28 days (p=0.001) and at two months (p=0.030). Polyurethane foam elicited more intense foreign-body reaction when compared with silicone foam. The number of vessels was higher in the capsules of the polyurethane foam implants 28 days after the operation. The capsule of the polyurethane foam implants showed a greater amount of collagen than that of the silicone foam implants.

  10. Pudendal nerve neuromodulation with neurophysiology guidance: a potential treatment option for refractory chronic pelvi-perineal pain.

    PubMed

    Carmel, Maude; Lebel, Michel; Tu, Le Mai

    2010-05-01

    Refractory chronic pelvi-perineal pain (RCPPP) is a challenging entity that has devastating consequences for patient's quality of life. Many etiologies have been proposed including pudendal neuralgia. Multiple treatment options are used but the reported results are sub-optimal and temporary. In this article, we present the technique of pudendal nerve neuromodulation with neurophysiology guidance as a treatment option for RCPPP. This technique is a two-step procedure that includes electrode implantation under neurophysiology guidance followed by the implantation of a permanent generator after a successful trial period. We report the cases of three women who underwent this procedure as a last-resort treatment option. After 2 years of follow-up, their symptoms are still significantly improved. No major complication occurred.

  11. Current State and Future Perspectives of Energy Sources for Totally Implantable Cardiac Devices.

    PubMed

    Bleszynski, Peter A; Luc, Jessica G Y; Schade, Peter; PhilLips, Steven J; Tchantchaleishvili, Vakhtang

    There is a large population of patients with end-stage congestive heart failure who cannot be treated by means of conventional cardiac surgery, cardiac transplantation, or chronic catecholamine infusions. Implantable cardiac devices, many designated as destination therapy, have revolutionized patient care and outcomes, although infection and complications related to external power sources or routine battery exchange remain a substantial risk. Complications from repeat battery replacement, power failure, and infections ultimately endanger the original objectives of implantable biomedical device therapy - eliminating the intended patient autonomy, affecting patient quality of life and survival. We sought to review the limitations of current cardiac biomedical device energy sources and discuss the current state and trends of future potential energy sources in pursuit of a lifelong fully implantable biomedical device.

  12. Peri-implantitis.

    PubMed

    Schwarz, Frank; Derks, Jan; Monje, Alberto; Wang, Hom-Lay

    2018-06-01

    This narrative review provides an evidence-based overview on peri-implantitis for the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions. A literature review was conducted addressing the following topics: 1) definition of peri-implantitis; 2) conversion from peri-implant mucositis to peri-implantitis, 3) onset and pattern of disease progression, 4) characteristics of peri-implantitis, 5) risk factors/indicators for peri-implantitis, and 6) progressive crestal bone loss in the absence of soft tissue inflammation. 1)Peri-implantitis is a pathological condition occurring in tissues around dental implants, characterized by inflammation in the peri-implant connective tissue and progressive loss of supporting bone. 2)The histopathologic and clinical conditions leading to the conversion from peri-implant mucositis to peri-implantitis are not completely understood. 3)The onset of peri-implantitis may occur early during follow-up and the disease progresses in a non-linear and accelerating pattern. 4a)Peri-implantitis sites exhibit clinical signs of inflammation and increased probing depths compared to baseline measurements. 4b)At the histologic level, compared to periodontitis sites, peri-implantitis sites often have larger inflammatory lesions. 4c)Surgical entry at peri-implantitis sites often reveals a circumferential pattern of bone loss. 5a)There is strong evidence that there is an increased risk of developing peri-implantitis in patients who have a history of chronic periodontitis, poor plaque control skills, and no regular maintenance care after implant therapy. Data identifying "smoking" and "diabetes" as potential risk factors/indicators for peri-implantitis are inconclusive. 5b)There is some limited evidence linking peri-implantitis to other factors such as: post-restorative presence of submucosal cement, lack of peri-implant keratinized mucosa and positioning of implants that make it difficult to perform oral hygiene and maintenance. 6)Evidence suggests that progressive crestal bone loss around implants in the absence of clinical signs of soft tissue inflammation is a rare event. © 2018 American Academy of Periodontology and European Federation of Periodontology.

  13. Optical methods for wireless implantable sensing platforms

    NASA Astrophysics Data System (ADS)

    Mujeeb-U-Rahman, Muhammad; Chang, Chieh-Feng; Scherer, Axel

    2013-09-01

    Ultra small scale implants have gained lots of importance for both acute and chronic applications. Optical techniques hold the key to miniaturizing these devices to long sought sub-mm scale. This will lead towards long term use of these devices for medically relevant applications. It can also allow using multiple of these devices at the same time and forming a true body area network of sensors. In this paper, we present optical power transfer to such devices and the techniques to harness this power for different applications, for example high voltage or high current applications. We also present methods for wireless data transfer from such implants.

  14. Relationship between oral cancer and implants: clinical cases and systematic literature review

    PubMed Central

    López-López, José; Roselló-Llabrés, Xavier; Rodríguez-Argueta, Oscar-Francisco; Chimenos-Küstner, Eduardo

    2012-01-01

    The use of implants for oral rehabilitation of edentulous spaces has recently been on the increase, which has also led to an increase in complications such as peri-implant inflammation or periimplantitis. Chronic inflammation is a risk factor for developing oral squamous cell carcinoma (OSCC). Objectives: To review the literature of cases that associate implant placement with the development of oral cancer. Study design: We present two clinical cases and a systematic review of literature published on the relationship between oral cancer and implants. Results: We found 13 articles published between the years 1996 and 2009, referencing 18 cases in which the osseointegrated implants are associated with oral squamous cell carcinoma. Of those, 6 articles were excluded because they did not meet the inclusion criteria. Of the 18 cases reported, only 7 cases did not present a previous history of oral cancer or cancer in other parts of the body. Conclusions: Based on the review of these cases, a clear cause-effect relationship cannot be established, although it can be deduced that there is a possibility that implant treatment may constitute an irritant and/or inflammatory cofactor which contributes to the formation and/or development of OSCC. Key words: Cancer, oral cancer, dental implants, oral squamous cell carcinoma, dental implants complications. PMID:21743414

  15. Intra-Aortic Balloon Counterpulsation in Patients with Chronic Heart Failure and Cardiogenic Shock: Clinical Response and Predictors of Stabilization

    PubMed Central

    Sintek, Marc A.; Gdowski, Mark; Lindman, Brian R.; Nassif, Michael; Lavine, Kory J.; Novak, Eric; Bach, Richard G.; Silvestry, Scott C.; Mann, Douglas L.; Joseph, Susan M.

    2015-01-01

    Objective To characterize the clinical response and identify predictors of clinical stabilization after intra-aortic balloon counterpulsation (IABP) support in patients with chronic systolic heart failure in cardiogenic shock prior to implantation of a left ventricular assist device (LVAD). Background Limited data exist regarding the clinical response to IABP in patients with chronic heart failure in cardiogenic shock. Methods We identified 54 patients supported with IABP prior to LVAD implantation. Criteria for clinical decompensation after IABP insertion and before LVAD included the need for more advanced temporary support, initiation of mechanical ventilation or dialysis, increase in vasopressors/inotropes, refractory ventricular arrhythmias, or worsening acidosis. The absence of these indicated stabilization. Results Clinical decompensation after IABP occurred in 23 (43%) patients. Both patients who decompensated and those who stabilized had similar hemodynamic improvements after IABP support but patients who decompensated required more vasopressors/inotropes. Clinical decompensation after IABP was associated with worse outcomes after LVAD implantation, including a 3-fold longer intensive care unit stay and 5-fold longer time on mechanical ventilation (p<0.01 for both). While baseline characteristics were similar between groups, right and left ventricular cardiac power indices (Cardiac power Index= Cardiac Index × Mean arterial pressure / 451)identified patients who were likely to stabilize (AUC=0.82). Conclusions Among patients with chronic systolic heart failure who develop cardiogenic shock, more than half of patients stabilized with IABP support as a bridge to LVAD. Baseline measures of right and left ventricular cardiac power, both measures of work performed for a given flow and pressure, may allow clinicians to identify patients with sufficient contractile reserve who will be likely to stabilize with an IABP versus those who may need more aggressive ventricular support. PMID:26164215

  16. Neurostimulation of the Lacrimal Nerve for Enhanced Tear Production

    PubMed Central

    Kossler, Andrea L.; Wang, Jianhua; Feuer, William; Tse, David T.

    2014-01-01

    Purpose To design a proof-of-concept study to assess the effect of lacrimal nerve stimulation (LNS) with an implantable pulse generator (IPG) to increase aqueous tear production. Methods Experimental animal study design of six Dutch Belted rabbits. Ultra high-resolution optical coherence tomography (UHR-OCT) quantified tear production by measuring the baseline tear volume of each rabbit’s right and left eye. A neurostimulator was implanted adjacent to the right lacrimal nerve. After two minutes of LNS (100 μs, 1.6 mAmp, 20 Hz, 5–8 volts), the tear volumes were measured with UHR-OCT. The change in tear volume was quantified and compared to the non-stimulated left eye. Three rabbits underwent chronic LNS (100 μS, 1.6 mAmp, 10 Hz, 2 volts) and their lacrimal glands were harvested for histopathologic analysis. Results UHR-OCT imaging of the right eyes tear volume showed a 441% average increase in tear production after LNS as a percent of baseline. After stimulation, right eyes had statistically significant greater increase in tear volumes than left eyes (p=0.028, Wilcoxon test). Post-stimulation right eye tear volumes were significantly greater compared to baseline (p=0.028, Wilcoxon test). Histopathologic examination of the lacrimal glands showed no discernible tissue damage from chronic neurostimulation. Additionally, there were no gross adverse effects on the general well-beings of the animals due to chronic stimulation. Conclusions Lacrimal nerve stimulation with an implantable pulse generator appears to increase aqueous tear production. Chronic LNS showed no histopathologic lacrimal gland damage. This study suggests LNS is a promising new treatment strategy to increase aqueous tear production. PMID:25126767

  17. Chronic exposure to bisphenol a impairs progesterone receptor-mediated signaling in the uterus during early pregnancy

    PubMed Central

    Li, Quanxi; Davila, Juanmahel; Bagchi, Milan K.; Bagchi, Indrani C.

    2016-01-01

    Environmental and occupational exposure to endocrine disrupting chemicals (EDCs) is a major threat to female reproductive health. Bisphenol A (BPA), an environmental toxicant that is commonly found in polycarbonate plastics and epoxy resins, has received much attention due to its estrogenic activity and high risk of chronic exposure in human. Whereas BPA has been linked to infertility and recurrent miscarriage in women, the impact of its exposure on uterine function during early pregnancy remains unclear. In a recent publication in Endocrinology, we demonstrated that prolonged exposure to an environmental relevant dose of BPA disrupts progesterone receptor-regulated uterine functions, thus affecting uterine receptivity for embryo implantation and decidua morphogenesis, two critical events for establishment and maintenance of early pregnancy. In particular we reported a marked impairment of progesterone receptor (PGR) expression and its downstream effector HAND2 in the uterine stromal cells in response to chronic BPA exposure. In an earlier study we have shown that HAND2 controls embryo implantation by repressing fibroblast growth factor (FGF) expression and the MAP kinase signaling pathway, thus inhibiting epithelial proliferation. Interestingly we observed that downregulation of PGR and HAND2 expression in uterine stroma upon BPA exposure was associated with an enhanced activation of FGFR and MAPK signaling, aberrant proliferation, and lack of uterine receptivity in the epithelium. In addition, the proliferation and differentiation of endometrial stromal cells to decidual cells, an event critical for the maintenance of early pregnancy, was severely compromised in response to BPA. This research highlight will provide an overview of our findings and discuss the potential mechanisms by which chronic BPA impairs PGR-HAND2 pathway and adversely affects implantation and the establishment of pregnancy. PMID:28239613

  18. Morphological correlates of hearing loss after cochlear implantation and electro-acoustic stimulation in a hearing-impaired Guinea pig model.

    PubMed

    Reiss, Lina A J; Stark, Gemaine; Nguyen-Huynh, Anh T; Spear, Kayce A; Zhang, Hongzheng; Tanaka, Chiemi; Li, Hongzhe

    2015-09-01

    Hybrid or electro-acoustic stimulation (EAS) cochlear implants (CIs) are designed to provide high-frequency electric hearing together with residual low-frequency acoustic hearing. However, 30-50% of EAS CI recipients lose residual hearing after implantation. The objective of this study was to determine the mechanisms of EAS-induced hearing loss in an animal model with high-frequency hearing loss. Guinea pigs were exposed to 24 h of noise (12-24 kHz at 116 dB) to induce a high-frequency hearing loss. After recovery, two groups of animals were implanted (n = 6 per group), with one group receiving chronic acoustic and electric stimulation for 10 weeks, and the other group receiving no stimulation during this time frame. A third group (n = 6) was not implanted, but received chronic acoustic stimulation. Auditory brainstem responses were recorded biweekly to monitor changes in hearing. The organ of Corti was immunolabeled with phalloidin, anti-CtBP2, and anti-GluR2 to quantify hair cells, ribbons and post-synaptic receptors. The lateral wall was immunolabeled with phalloidin and lectin to quantify stria vascularis capillary diameters. Bimodal or trimodal diameter distributions were observed; the number and location of peaks were objectively determined using the Aikake Information Criterion and Expectation Maximization algorithm. Noise exposure led to immediate hearing loss at 16-32 kHz for all groups. Cochlear implantation led to additional hearing loss at 4-8 kHz; this hearing loss was negatively and positively correlated with minimum and maximum peaks of the bimodal or trimodal distributions of stria vascularis capillary diameters, respectively. After chronic stimulation, no significant group changes in thresholds were seen; however, elevated thresholds at 1 kHz in implanted, stimulated animals were significantly correlated with decreased presynaptic ribbon and postsynaptic receptor counts. Inner and outer hair cell counts did not differ between groups and were not correlated with threshold shifts at any frequency. As in the previous study in a normal-hearing model, stria vascularis capillary changes were associated with immediate hearing loss after implantation, while little to no hair cell loss was observed even in cochlear regions with threshold shifts as large as 40-50 dB. These findings again support a role of lateral wall blood flow changes, rather than hair cell loss, in hearing loss after surgical trauma, and implicate the endocochlear potential as a factor in implantation-induced hearing loss. Further, the analysis of the hair cell ribbons and post-synaptic receptors suggest that delayed hearing loss may be linked to synapse or peripheral nerve loss due to stimulation excitotoxicity or inflammation. Further research is needed to separate these potential mechanisms of delayed hearing loss. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Oral Effects and Early Implant Survival Results After Imatinib Discontinuation Therapy for Chronic Myelogenous Leukemia: A Case Report.

    PubMed

    Dixon, Douglas R; Yassin, Alaa

    2017-08-01

    Little is known regarding the success, failure, or complication rates of advanced implant procedures in patients after discontinuation therapy of long-term medications for the treatment of chronic myelogenous leukemia (CML). This case report presents initial results of a case involving implant placement in the mandible and maxilla as well as reduction of palatal oral pigmentation in a patient discontinuing long-term tyrosine kinase inhibitor (TKI) therapy for CML. A 57-year-old male was referred to the Department of Periodontics, University of Washington, Seattle, Washington, for an assessment of edentulous areas (tooth sites #3 and #14) and failing tooth #19. Previous medical treatment included oral administration (>10 years) of TKI for the treatment of CML. Systemic complications arising from long-term TKI therapy were treated with discontinuation of this medication. Concurrently, after multispecialty dental and medical consultation, extraction of tooth #19 with immediate implant placement and bilateral sinus augmentation with simultaneous implant placement were successfully performed during three separate surgical appointments. Additionally, marked reduction of oral palatal pigmentation was observed during the surgical and restorative phases after TKI discontinuation. Patients with a history of long-term TKIs for CML are at risk for developing complications that result in discontinuation of therapy. Long-term benefits of therapy may allow these patients to enjoy remission with an extended and improved quality of life. Patients undergoing discontinuation therapy may seek dental care. Therefore, dental providers need to understand these systemic interactions and, with multispecialty consultation, may help effectively treat these individuals.

  20. Chronic recruitment of primary afferent neurons by microstimulation in the feline dorsal root ganglia

    NASA Astrophysics Data System (ADS)

    Fisher, Lee E.; Ayers, Christopher A.; Ciollaro, Mattia; Ventura, Valérie; Weber, Douglas J.; Gaunt, Robert A.

    2014-06-01

    Objective. This study describes results of primary afferent neural microstimulation experiments using microelectrode arrays implanted chronically in the lumbar dorsal root ganglia (DRG) of four cats. The goal was to test the stability and selectivity of these microelectrode arrays as a potential interface for restoration of somatosensory feedback after damage to the nervous system such as amputation. Approach. A five-contact nerve-cuff electrode implanted on the sciatic nerve was used to record the antidromic compound action potential response to DRG microstimulation (2-15 µA biphasic pulses, 200 µs cathodal pulse width), and the threshold for eliciting a response was tracked over time. Recorded responses were segregated based on conduction velocity to determine thresholds for recruiting Group I and Group II/Aβ primary afferent fibers. Main results. Thresholds were initially low (5.1 ± 2.3 µA for Group I and 6.3 ± 2.0 µA for Group II/Aβ) and increased over time. Additionally the number of electrodes with thresholds less than or equal to 15 µA decreased over time. Approximately 12% of tested electrodes continued to elicit responses at 15 µA up to 26 weeks after implantation. Higher stimulation intensities (up to 30 µA) were tested in one cat at 23 weeks post-implantation yielding responses on over 20 additional electrodes. Within the first six weeks after implantation, approximately equal numbers of electrodes elicited only Group I or Group II/Aβ responses at threshold, but the relative proportion of Group II/Aβ responses decreased over time. Significance. These results suggest that it is possible to activate Group I or Group II/Aβ primary afferent fibers in isolation with penetrating microelectrode arrays implanted in the DRG, and that those responses can be elicited up to 26 weeks after implantation, although it may be difficult to achieve a consistent response day-to-day with currently available electrode technology. The DRG are compelling targets for sensory neuroprostheses with potential to achieve recruitment of a range of sensory fiber types over multiple months after implantation.

  1. Hearing after congenital deafness: central auditory plasticity and sensory deprivation.

    PubMed

    Kral, A; Hartmann, R; Tillein, J; Heid, S; Klinke, R

    2002-08-01

    The congenitally deaf cat suffers from a degeneration of the inner ear. The organ of Corti bears no hair cells, yet the auditory afferents are preserved. Since these animals have no auditory experience, they were used as a model for congenital deafness. Kittens were equipped with a cochlear implant at different ages and electro-stimulated over a period of 2.0-5.5 months using a monopolar single-channel compressed analogue stimulation strategy (VIENNA-type signal processor). Following a period of auditory experience, we investigated cortical field potentials in response to electrical biphasic pulses applied by means of the cochlear implant. In comparison to naive unstimulated deaf cats and normal hearing cats, the chronically stimulated animals showed larger cortical regions producing middle-latency responses at or above 300 microV amplitude at the contralateral as well as the ipsilateral auditory cortex. The cortex ipsilateral to the chronically stimulated ear did not show any signs of reduced responsiveness when stimulating the 'untrained' ear through a second cochlear implant inserted in the final experiment. With comparable duration of auditory training, the activated cortical area was substantially smaller if implantation had been performed at an older age of 5-6 months. The data emphasize that young sensory systems in cats have a higher capacity for plasticity than older ones and that there is a sensitive period for the cat's auditory system.

  2. Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring

    NASA Astrophysics Data System (ADS)

    Mueller, Matthias; de la Oliva, Natalia; del Valle, Jaume; Delgado-Martínez, Ignacio; Navarro, Xavier; Stieglitz, Thomas

    2017-12-01

    Objective. Interfacing the peripheral nervous system can be performed with a large variety of electrode arrays. However, stimulating and recording a nerve while having a reasonable amount of channels limits the number of available systems. Translational research towards human clinical trial requires device safety and biocompatibility but would benefit from design flexibility in the development process to individualize probes. Approach. We selected established medical grade implant materials like precious metals and Parylene C to develop a rapid prototyping process for novel intrafascicular electrode arrays using a picosecond laser structuring. A design for a rodent animal model was developed in conjunction with an intrafascicular implantation strategy. Electrode characterization and optimization was performed first in saline solution in vitro before performance and biocompatibility were validated in sciatic nerves of rats in chronic implantation. Main results. The novel fabrication process proved to be suitable for prototyping and building intrafascicular electrode arrays. Electrochemical properties of the electrode sites were enhanced and tested for long-term stability. Chronic implantation in the sciatic nerve of rats showed good biocompatibility, selectivity and stable stimulation thresholds. Significance. Established medical grade materials can be used for intrafascicular nerve electrode arrays when laser structuring defines structure size in the micro-scale. Design flexibility reduces re-design cycle time and material certificates are beneficial support for safety studies on the way to clinical trials.

  3. Flow dynamics of a novel counterpulsation device characterized by CFD and PIV modeling

    PubMed Central

    Giridharan, GA; Lederer, C; Berthe, A; Goubergrits, L; Hutzenlaub, J; Slaughter, MS; Dowling, RD; Spence, PA; Koenig, SC

    2017-01-01

    Background Historically, single port valveless pneumatic blood pumps have had a high incidence of thrombus formation due to areas of blood stagnation and hemolysis due to areas of high shear stress. Methods To ensure minimal hemolysis and favorable blood washing characteristics, Particle Image Velocimetry (PIV) and Computational Fluid Dynamics (CFD) were used to evaluate the design of a new single port, valveless counterpulsation device (Symphony). The Symphony design was tested in 6-hour acute (n=8), 5-day (n=8) and 30-day (n=2) chronic experiments in a calf model (Jersey, 76 kg). Venous blood samples were collected during acute (hourly) and chronic (weekly) time courses to analyze for temporal changes in biochemical markers and quantify plasma free hemoglobin. At the end of the study, animals were euthanized and the Symphony and end-organs (brain, liver, kidney, lungs, heart, and spleen) were examined for thrombus formations. Results Both the PIV and CFD showed the development of a strong moving vortex during filling phase and that blood exited the Symphony uniformly from all areas during ejection phase. The laminar shear stresses estimated by CFD remained well below the hemolysis threshold of 400 Pa inside the Symphony throughout filling and ejection phases. No areas of persistent blood stagnation or flow separation were observed. The maximum plasma free hemoglobin (< 10 mg/dl), average platelet count (pre-implant = 473 ± 56 K/μL and post-implant = 331 ± 62 K/μL), and average hematocrit (pre-implant = 31 ± 2 % and post-implant = 29 ± 2 %) were normal at all measured time-points for each test animal in acute and chronic experiments. There were no changes in measures of hepatic function (ALP, ALT) or renal function (creatinine) from pre-Symphony implantation values. The necropsy examination showed no signs of thrombus formation in the Symphony or end organs. Conclusions These data suggest that the designed Symphony has good washing characteristics without persistent areas of blood stagnation sites during the entire pump cycle, and has a low risk of hemolysis and thrombus formations. PMID:21680224

  4. Mechanical Evaluation of Unobstructing Magnetic Microactuators for Implantable Ventricular Catheters

    PubMed Central

    Lee, Hyowon; Kolahi, Kameran; Bergsneider, Marvin; Judy, Jack W.

    2017-01-01

    Here, we report on the development and evaluation of novel unobstructing magnetic microactuators for maintaining the patency of implantable ventricular catheters used in hydrocephalus application. The treatment of hydrocephalus requires chronic implantation of a shunt system to divert excess cerebrospinal fluid from the brain. These shunt systems suffer from a high failure rate (>40%) within the first year of implantation, often due to biological accumulation. Previously, we have shown that magnetic microactuators can be used to remove biological blockage. The new cantilever-based magnetic microactuator presented in this paper improves upon the previous torsional design using a bimorph to induce a postrelease out-of-plane deflection that will prevent the device from occluding the pore at rest. The mechanical evaluations (i.e., postrelease deflection, static and dynamic responses) of fabricated devices are reported and compared with theoretical values. PMID:29151776

  5. Flexible-Device Injector with a Microflap Array for Subcutaneously Implanting Flexible Medical Electronics.

    PubMed

    Song, Kwangsun; Kim, Juho; Cho, Sungbum; Kim, Namyun; Jung, Dongwuk; Choo, Hyuck; Lee, Jongho

    2018-06-25

    Implantable electronics in soft and flexible forms can reduce undesired outcomes such as irritations and chronic damages to surrounding biological tissues due to the improved mechanical compatibility with soft tissues. However, the same mechanical flexibility also makes it difficult to insert such implants through the skin because of reduced stiffness. In this paper, a flexible-device injector that enables the subcutaneous implantation of flexible medical electronics is reported. The injector consists of a customized blade at the tip and a microflap array which holds the flexible implant while the injector penetrates through soft tissues. The microflap array eliminates the need of additional materials such as adhesives that require an extended period to release a flexible medical electronic implant from an injector inside the skin. The mechanical properties of the injection system during the insertion process are experimentally characterized, and the injection of a flexible optical pulse sensor and electrocardiogram sensor is successfully demonstrated in vivo in live pig animal models to establish the practical feasibility of the concept. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Spatial and temporal characteristics of V1 microstimulation during chronic implantation of a microelectrode array in a behaving macaque

    NASA Astrophysics Data System (ADS)

    Davis, T. S.; Parker, R. A.; House, P. A.; Bagley, E.; Wendelken, S.; Normann, R. A.; Greger, B.

    2012-12-01

    Objective. It has been hypothesized that a vision prosthesis capable of evoking useful visual percepts can be based upon electrically stimulating the primary visual cortex (V1) of a blind human subject via penetrating microelectrode arrays. As a continuation of earlier work, we examined several spatial and temporal characteristics of V1 microstimulation. Approach. An array of 100 penetrating microelectrodes was chronically implanted in V1 of a behaving macaque monkey. Microstimulation thresholds were measured using a two-alternative forced choice detection task. Relative locations of electrically-evoked percepts were measured using a memory saccade-to-target task. Main results. The principal finding was that two years after implantation we were able to evoke behavioural responses to electric stimulation across the spatial extent of the array using groups of contiguous electrodes. Consistent responses to stimulation were evoked at an average threshold current per electrode of 204 ± 49 µA (mean ± std) for groups of four electrodes and 91 ± 25 µA for groups of nine electrodes. Saccades to electrically-evoked percepts using groups of nine electrodes showed that the animal could discriminate spatially distinct percepts with groups having an average separation of 1.6 ± 0.3 mm (mean ± std) in cortex and 1.0° ± 0.2° in visual space. Significance. These results demonstrate chronic perceptual functionality and provide evidence for the feasibility of a cortically-based vision prosthesis for the blind using penetrating microelectrodes.

  7. Patch testers' opinions regarding diagnostic criteria for metal hypersensitivity reactions to metallic implants.

    PubMed

    Schalock, Peter C; Thyssen, Jacob P

    2013-01-01

    Metal hypersensitivity reactions to implanted devices remain a challenging and controversial topic. Diagnostic criteria and methods are not well delineated. Diagnostic criteria for hypersensitivity reactions after metallic device implantation are evaluated in this study by a multinational group of patch testers using Thyssen's previously published criteria. A total of 119 dermatologists at the 2012 European Contact Dermatitis Society and 2013 American Contact Dermatitis Society meetings answered a survey regarding their opinions on topics relating to metal hypersensitivity. Four major and 5 minor diagnostic criteria emerged. Approximately 80% of respondents found the following criteria useful (major criteria): chronic dermatitis beginning weeks to months after metallic implantation, eruption overlying the metal implant, positive patch test to a metal component of the implant, and complete clearing after removal of the potentially allergenic implant. Minor criteria (<61% of respondents) were as follows: systemic allergic dermatitis reaction, therapy-resistant dermatitis, morphology consistent with dermatitis, histology consistent with allergic contact dermatitis, and a positive in vitro test to metals (eg, lymphocyte transformation test). In the challenging situation such as a symptomatic or failing orthopedic device, applying these 4 major criteria and the 5 supportive minor criteria may be useful for guiding decision making.

  8. Chronic impedance spectroscopy of an endovascular stent-electrode array

    NASA Astrophysics Data System (ADS)

    Opie, Nicholas L.; John, Sam E.; Rind, Gil S.; Ronayne, Stephen M.; Grayden, David B.; Burkitt, Anthony N.; May, Clive N.; O'Brien, Terence J.; Oxley, Thomas J.

    2016-08-01

    Objective. Recently, we reported a minimally invasive stent-electrode array capable of recording neural signals from within a blood vessel. We now investigate the use of electrochemical impedance spectroscopy (EIS) measurements to infer changes occurring to the electrode-tissue interface from devices implanted in a cohort of sheep for up to 190 days. Approach. In a cohort of 15 sheep, endovascular stent-electrode arrays were implanted in the superior sagittal sinus overlying the motor cortex for up to 190 days. EIS was performed routinely to quantify viable electrodes for up to 91 days. An equivalent circuit model (ECM) was developed from the in vivo measurements to characterize the electrode-tissue interface changes occurring to the electrodes chronically implanted within a blood vessel. Post-mortem histological assessment of stent and electrode incorporation into the wall of the cortical vessels was compared to the electrical impedance measurements. Main results. EIS could be used to infer electrode viability and was consistent with x-ray analysis performed in vivo, and post-mortem evaluation. Viable electrodes exhibited consistent 1 kHz impedances across the 91 day measurement period, with the peak resistance frequency for the acquired data also stable over time. There was a significant change in 100 Hz phase angles, increasing from -67.8° ± 8.8° at day 0 to -43.8° ± 0.8° at day 91, which was observed to stabilize after eight days. ECM’s modeled to the data suggested this change was due to an increase in the capacitance of the electrode-tissue interface. This was supported by histological assessment with >85% of the implanted stent struts covered with neointima and incorporated into the blood vessel within two weeks. Conclusion. This work demonstrated that EIS could be used to determine the viability of electrode implanted chronically within a blood vessel. Impedance measurements alone were not observed to be a useful predictor of alterations occurring at the electrode tissue interface. However, measurement of 100 Hz phase angles was in good agreement with the capacitive changes predicted by the ECM and consistent with suggestions that this represents protein absorption on the electrode surface. 100 Hz phase angles stabilized after 8 days, consistent with histologically assessed samples. Significance. These findings demonstrate the potential application of this technology for use as a chronic neural recording system and indicate the importance of conducting EIS as a measure to identify viable electrodes and changes occurring at the electrode-tissue interface.

  9. Implantation of active fixation leads in coronary veins for left ventricular stimulation: report of five cases.

    PubMed

    Hansky, Bert; Vogt, Juergen; Gueldner, Holger; Schulte-Eistrup, Sebastian; Lamp, Barbara; Heintze, Johannes; Horstkotte, Dieter; Koerfer, Reiner

    2007-01-01

    Securing transvenous left ventricular (LV) pacing leads without an active fixation mechanism in proximal coronary vein (CV) segments is usually challenging and frequently impossible. We investigated how active fixation leads can be safely implanted in this location, how to avoid perforating the free wall of the CV, and how to recognize and respond to perforations. In five patients with no alternative to LV pacing from proximal CV segments, 4 Fr SelectSecure (Medtronic, Minneapolis, MN, USA) leads, which have a fixed helix, were implanted through a modified 6 Fr guide catheter with a pre-shaped tip (Launcher, Medtronic). Active fixation leads were successfully implanted in proximal CVs in five patients. There were no complications. Acute and chronic pacing thresholds were comparable to those of conventional CV leads. The pre-shaped guide catheter tip remains in close proximity to the myocardial aspect of the CV, directing the lead helix toward a safe implantation site. If only proximal CV pacing sites are available, 4 Fr SelectSecure leads can be safely implanted through a modified Launcher guide catheter, avoiding more invasive implantation techniques. Other than venous stenting or implantation of leads with retractable tines, SelectSecure leads are expected to remain extractable.

  10. Resorbable Self-Locking Implant for Lung Lobectomy Through Video-Assisted Thoracoscopic Surgery: First Live Animal Application.

    PubMed

    Guedes, Rogério Luizari; Höglund, Odd Viking; Brum, Juliana Sperotto; Borg, Niklas; Dornbusch, Peterson Triches

    2018-04-01

    The aim of this pilot test was to test a new self-locking resorbable implant for hilum occlusion during a video-assisted thoracoscopic lung lobectomy in a surviving pig model. Once the thoracic cavity was assessed and structures identified, the right middle lobe and its respective hilum were exposed. The implant was introduced with a semiclosed loop through a working channel and positioned around the pulmonary lobe. Occlusion was performed with a conventional Crile forceps and a laparoscopic Kelly forceps. Lobe section was done with laparoscopic Metzenbaum scissors and tissue removal through the dorsal access. No signs of pneumothorax or bleeding were observed during a 60-day follow-up. Necropsy findings showed minimal pleuritis in caudal access and in the lobar stump. A granulomatous formation was found around a dense, amorphous material, which was identified as remains of a small part of the implant. Histopathological findings showed signs of a chronic healing process without other alterations. The resorbable implant LigaTie appears to exhibit similar handling and application characteristics during surgery as nonsurgical tie wraps. The resorbable implant avoids the uncontrolled substances not suitable for implants of conventional ties. The results of this pilot test suggested the resorbable implant's mechanical properties provided effective tissue support to complete the healing of the pulmonary hilum.

  11. Longterm infrared neural stimulation in the chronic implanted cat

    NASA Astrophysics Data System (ADS)

    Matic, Agnella Izzo; Robinson, Alan M.; Young, Hunter K.; Badofsky, Ben; Rajguru, Suhrud M.; Richter, Claus-Peter

    2013-03-01

    Among neural prostheses cochlear implants (CIs) are considered the most successful devices. They restore some hearing to 210,000 severe-to-profound hearing impaired people. Despite the devices' success, the performance of the implanted individuals in noisy environments is poor and music perception is rudimentary. It has been argued that increasing the number of independent channels for stimulation can improve the performance of a CI user in challenging hearing environments. An optical method, stimulating neurons with infrared radiation, has been suggested as a novel approach to increase the number of independent channels. Infrared neural stimulation (INS) works through the deposition of heat into the tissue. Thermal damage is therefore a potential risk, particularly for longterm exposure. To verify the efficacy and safety of INS, cats were implanted for about 4 weeks and were continuously stimulated daily for 6-8 hours. Cochlear function did not change during the stimulation, and histology did not reveal signs of damage. Tissue growth following the implantation was largely localized at the cochleostomy.

  12. Periprosthetic bleeding 18 years post-silicone reconstruction of the orbital floor.

    PubMed

    Ilie, Vlad Ionut; Ilie, Victor George; Quarmby, Craig; Lefter, Mihaela

    2011-10-01

    Periprosthetic orbital haemorrhage is an uncommon complication of the alloplastic implants used in post-traumatic orbital floor repair. The small case series or individual reports provide no definite causative explanation for this delayed bleeding around silicone implants. It is likely that it is related to the disruption of fine capillaries within the pseudocapsule surrounding the implant, since the material does cause low-grade irritation with evidence of chronic inflammation. We report the case of a patient who developed a spontaneous periprosthetic bleeding 18 years' post-silicone sheet reconstruction of the orbital floor. Urgent removal of the implant insured prompt resolution of all symptoms and no further problem during the 2-year follow-up. This report emphasizes that periprosthetic orbital haemorrhage can occur years after the initial repair. Awareness of this rare complication allows for prompt diagnosis, decreasing the possibility of permanent damage of the orbital content. The removal of implant is necessary to relieve the symptoms and prevent potential infective complications.

  13. Biocompatibility of Ricinus communis polymer with addition of calcium carbonate compared to titanium. Experimental study in guinea pigs

    PubMed Central

    Graça, Yorgos Luiz Santos De Salles; Opolski, Ana Cristina; Barboza, Barbara Evelin Gonçalves; Erbano, Bruna Olandoski; Mazzaro, Caroline Cantalejo; Klostermann, Flávia Caroline; Sucharski, Enéas Eduardo; Kubrusly, Luiz Fernando

    2014-01-01

    Objective The aim of the present investigation was to determine whether the difference in inflammatory tissue reaction between the Riccinus communis (castor) polymer with calcium carbonate and the titanium implant is statistically significant. Methods Thirty-two Cavia porcellus were allocated into four groups of eight animals each. We implanted the two types of materials in the retroperitoneal space of all the animals. They were euthanized at 7, 20, 30 and 40 days after surgery, and an histological study of the samples was conducted. Results All implants showed characteristics of chronic inflammation regardless of the material and timepoint of evaluation. There was no statistically significant difference between Pm+CaCO3 and Ti with regard to the presence of granulation tissue, tissue congestion, histiocytes, lymphocytes, neutrophils, giant cells, and fibrosis (P> 0.05). Conclusion The castor oil polymer plus calcium carbonate implant was not statistically different from the titanium implant regarding inflammatory tissue reaction. PMID:25140479

  14. Polymeric nanofiber coating with tunable combinatorial antibiotic delivery prevents biofilm-associated infection in vivo

    PubMed Central

    Ashbaugh, Alyssa G.; Jiang, Xuesong; Zheng, Jesse; Tsai, Andrew S.; Kim, Woo-Shin; Thompson, John M.; Miller, Robert J.; Shahbazian, Jonathan H.; Wang, Yu; Dillen, Carly A.; Ordonez, Alvaro A.; Chang, Yong S.; Jain, Sanjay K.; Jones, Lynne C.; Sterling, Robert S.; Mao, Hai-Quan; Miller, Lloyd S.

    2016-01-01

    Bacterial biofilm formation is a major complication of implantable medical devices that results in therapeutically challenging chronic infections, especially in cases involving antibiotic-resistant bacteria. As an approach to prevent these infections, an electrospun composite coating comprised of poly(lactic-coglycolic acid) (PLGA) nanofibers embedded in a poly(ε-caprolactone) (PCL) film was developed to locally codeliver combinatorial antibiotics from the implant surface. The release of each antibiotic could be adjusted by loading each drug into the different polymers or by varying PLGA:PCL polymer ratios. In a mouse model of biofilm-associated orthopedic-implant infection, three different combinations of antibiotic-loaded coatings were highly effective in preventing infection of the bone/joint tissue and implant biofilm formation and were biocompatible with enhanced osseointegration. This nanofiber composite-coating technology could be used to tailor the delivery of combinatorial antimicrobial agents from various metallic implantable devices or prostheses to effectively decrease biofilm-associated infections in patients. PMID:27791154

  15. Search and Neutralize Factors (CSPGs) that Induce Decline in Transmission to Motoneurons from Spared Fibers after Chronic Spinal Cord Injury

    DTIC Science & Technology

    2013-10-01

    animals received a subcutaneous injection of Buprenorphine (0.01mg/kg) to reduce post-operative pain. Contusion injury was performed at T10 spinal...HX SCI is attached). A downside of administration of NG2-antibody vial mini- pump in clinics is that it requires intrathecal implantation of the...principle, some recent clinical studies (Novartis clinical trials) showed that similar delivery of therapeutic agents using catheter implantation may

  16. Oral cancer or periimplantitis: A clinical dilemma.

    PubMed

    Bhandari, Sudhir; Rattan, Vidya; Panda, Naresh; Vaiphei, Kim; Mittal, Bhagwant Rai

    2016-06-01

    The purpose of this article was to draw attention to a periimplantitis-like clinical presentation of oral malignancy around dental implants, a phenomenon that may develop without any associated risk factors for oral cancer. Such a benign appearance of oral malignancy may lead to delay in the diagnosis and initiation of ensuing treatment. Therefore, chronic nonhealing inflammatory lesions around dental implants should be considered as highly suspicious. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Vestibular functions and sleep in space experiments. [using rhesus and owl monkeys

    NASA Technical Reports Server (NTRS)

    Perachio, A. A.

    1977-01-01

    Physical indices of sleep were continuously monitored in an owl monkey living in a chamber continuously rotating at a constant angular velocity. The electrophysiological data obtained from chronically implanted electrodes was analyzed to determine the chronic effects of vestibular stimulation on sleep and wakefulness cycles. The interaction of linear and angular acceleration on the vestibulo-ocular reflex was investigated in three rhesus monkeys at various angular accelerations.

  18. Sacral electrical neuromodulation as an alternative treatment option for lower urinary tract dysfunction.

    PubMed

    Grünewald, Volker; Höfner, Klaus; Thon, Walter F.; Kuczyk, Markus A.; Jonas, Udo

    1999-01-01

    Temporary electrical stimulation using anal or vaginal electrodes and an external pulse generator has been a treatment modality for urinary urge incontinence for nearly three decades. In 1981 Tanagho and Schmidt introduced chronic electrical stimulation of the sacral spinal nerves using a permanently implanted sacral foramen electrode and a battery powered pulse generator for treatment of different kinds of lower urinary tract dysfunction, refractory to conservative treatment. At our department chronic unilateral electrical stimulation of the S3 sacral spinal nerve has been used for treatment of vesi-courethral dysfunction in 43 patients with a mean postoperative follow up of 43,6 months. Lasting symptomatic improvement by more than 50 % could be achieved in 13 of 18 patients with motor urge incontinence (72,2 %) and in 18 of the 21 patients with urinary retention (85,7 %). Implants offer a sustained therapeutic effect to treatment responders, which is not achieved by temporary neuromodulation. Chronic neuromodulation should be predominantly considered in patients with urinary retention. Furthermore in patients with motor urge incontinence, refusing temporary techniques or in those requiring too much effort to achieve a sustained clinical effect. Despite high initial costs chronic sacral neuromodulation is an economically reasonable treatment option in the long run, when comparing it to the more invasive remaining therapeutic alternatives.

  19. Factors associated with Hearing Loss in a Normal-Hearing Guinea Pig Model of Hybrid Cochlear Implants

    PubMed Central

    Tanaka, Chiemi; Nguyen-Huynh, Anh; Loera, Katherine; Stark, Gemaine; Reiss, Lina

    2014-01-01

    The Hybrid cochlear implant (CI), also known as Electro- Acoustic Stimulation (EAS), is a new type of CI that preserves residual acoustic hearing and enables combined cochlear implant and hearing aid use in the same ear. However, 30-55% of patients experience acoustic hearing loss within days to months after activation, suggesting that both surgical trauma and electrical stimulation may cause hearing loss. The goals of this study were to: 1) determine the contributions of both implantation surgery and EAS to hearing loss in a normal-hearing guinea pig model; 2) determine which cochlear structural changes are associated with hearing loss after surgery and EAS. Two groups of animals were implanted (n=6 per group), with one group receiving chronic acoustic and electric stimulation for 10 weeks, and the other group receiving no direct acoustic or electric stimulation during this time frame. A third group (n=6) was not implanted, but received chronic acoustic stimulation. Auditory brainstem response thresholds were followed over time at 1, 2, 6, and 16 kHz. At the end of the study, the following cochlear measures were quantified: hair cells, spiral ganglion neuron density, fibrous tissue density, and stria vascularis blood vessel density; the presence or absence of ossification around the electrode entry was also noted. After surgery, implanted animals experienced a range of 0-55 dB of threshold shifts in the vicinity of the electrode at 6 and 16 kHz. The degree of hearing loss was significantly correlated with reduced stria vascularis vessel density and with the presence of ossification, but not with hair cell counts, spiral ganglion neuron density, or fibrosis area. After 10 weeks of stimulation, 67% of implanted, stimulated animals had more than 10 dB of additional threshold shift at 1 kHz, compared to 17% of implanted, non-stimulated animals and 0% of non-implanted animals. This 1-kHz hearing loss was not associated with changes in any of the cochlear measures quantified in this study. The variation in hearing loss after surgery and electrical stimulation in this animal model is consistent with the variation in human patients. Further, these findings illustrate an advantage of a normal-hearing animal model for quantification of hearing loss and damage to cochlear structures without the confounding effects of chemical- or noise-induced hearing loss. Finally, this study is the first to suggest a role of the stria vascularis and damage to the lateral wall in implantation-induced hearing loss. Further work is needed to determine the mechanisms of implantation- and electrical-stimulation-induced hearing loss. PMID:25128626

  20. Biocompatibility and anti-microbiological activity characterization of novel coatings for dental implants: A primer for non-biologists

    NASA Astrophysics Data System (ADS)

    Monsees, Thomas

    2016-08-01

    With regard to biocompatibility, the cardinal requirement for dental implants and other medical devices that are in long-term contact with tissue is that the material does not cause any adverse effect to the patient. To warrant stability and function of the implant, proper osseointegration is a further prerequisite. Cells interact with the implant surface as the interface between bulk material and biological tissue. Whereas structuring, deposition of a thin film or other modifications of the surface are crucial parameters in determining favorable adhesion of cells, corrosion of metal surfaces and release of ions can affect cell viability. Both parameters are usually tested using in vitro cytotoxicity and adhesion assays with bone or fibroblasts cells. For bioactive surface modifications, further tests should be considered for biocompatibility evaluation. Depending on the type of modification, this may include analysis of specific cell functions or the determination of antimicrobial activities. The latter is of special importance as bacteria and yeast present in the oral cavity can be introduced during the implantation process and this may lead to chronic infections and implant failure. An antimicrobial coating of the implant is a way to avoid that. This review describes the essential biocompatibility assays for evaluation of new implant materials required by ISO 10993 and also gives an overview on recent test methods for specific coatings of dental implants.

  1. In vitro and in vivo analysis and characterization of engineered spinal neural implants (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Shor, Erez; Shoham, Shy; Levenberg, Shulamit

    2016-03-01

    Spinal cord injury is a devastating medical condition. Recent developments in pre-clinical and clinical research have started to yield neural implants inducing functional recovery after spinal cord transection injury. However, the functional performance of the transplants was assessed using histology and behavioral experiments which are unable to study cell dynamics and the therapeutic response. Here, we use neurophotonic tools and optogenetic probes to investigate cellular level morphology and activity characteristics of neural implants over time at the cellular level. These methods were used in-vitro and in-vivo, in a mouse spinal cord injury implant model. Following previous attempts to induce recovery after spinal cord injury, we engineered a pre-vascularized implant to obtain better functional performance. To image network activity of a construct implanted in a mouse spinal cord, we transfected the implant to express GCaMP6 calcium activity indicators and implanted these constructs under a spinal cord chamber enabling 2-photon chronic in vivo neural activity imaging. Activity and morphology analysis image processing software was developed to automatically quantify the behavior of the neural and vascular networks. Our experimental results and analyses demonstrate that vascularized and non-vascularized constructs exhibit very different morphologic and activity patterns at the cellular level. This work enables further optimization of neural implants and also provides valuable tools for continuous cellular level monitoring and evaluation of transplants designed for various neurodegenerative disease models.

  2. Implants in bone: part II. Research on implant osseointegration: material testing, mechanical testing, imaging and histoanalytical methods.

    PubMed

    von Wilmowsky, Cornelius; Moest, Tobias; Nkenke, Emeka; Stelzle, Florian; Schlegel, Karl Andreas

    2014-12-01

    In order to determine whether a newly developed implant material conforms to the requirements of biocompatibility, it must undergo rigorous testing. To correctly interpret the results of studies on implant material osseointegration, it is necessary to have a sound understanding of all the testing methods. The aim of this overview is to elucidate the methods that are used for the experimental evaluation of the osseointegration of implant materials. In recent decades, there has been a constant proliferation of new materials and surface modifications in the field of dental implants. This continuous development of innovative biomaterials requires a precise and detailed evaluation in terms of biocompatibility and implant healing before clinical use. The current gold standard is in vivo animal testing on well validated animal models. However, long-term outcome studies on patients have to follow to finally validate and show patient benefit. No experimental set-up can provide answers for all possible research questions. However, a certain transferability of the results to humans might be possible if the experimental set-up is carefully chosen for the aspects and questions being investigated. To enhance the implant survival rate in the rising number of patients with chronic diseases which compromise wound healing and osseointegration, dental implant research on compromised animal models will further gain importance in future.

  3. Antimicrobial Silk Ocular Drug Delivery Implant for Chronic Posterior Segment Diseases

    DTIC Science & Technology

    2016-06-01

    antibody bevacizumab. The device was covalently coated with the antibacterial polymer HMPE1 to protect against biofilm formation and the transmission of harmful bacterial to the interior of the ocular chamber.

  4. Responses evoked by a vestibular implant providing chronic stimulation.

    PubMed

    Thompson, Lara A; Haburcakova, Csilla; Gong, Wangsong; Lee, Daniel J; Wall, Conrad; Merfeld, Daniel M; Lewis, Richard F

    2012-01-01

    Patients with bilateral vestibular loss experience dehabilitating visual, perceptual, and postural difficulties, and an implantable vestibular prosthesis that could improve these symptoms would be of great benefit to these patients. In previous work, we have shown that a one-dimensional, unilateral canal prosthesis can improve the vestibulooccular reflex (VOR) in canal-plugged squirrel monkeys. In addition to the VOR, the potential effects of a vestibular prosthesis on more complex, highly integrative behaviors, such as the perception of head orientation and posture have remained unclear. We tested a one-dimensional, unilateral prosthesis in a rhesus monkey with bilateral vestibular loss and found that chronic electrical stimulation partially restored the compensatory VOR and also that percepts of head orientation relative to gravity were improved. However, the one-dimensional prosthetic stimulation had no clear effect on postural stability during quiet stance, but sway evoked by head-turns was modestly reduced. These results suggest that not only can the implementation of a vestibular prosthesis provide partial restitution of VOR but may also improve perception and posture in the presence of bilateral vestibular hypofunction (BVH). In this review, we provide an overview of our previous and current work directed towards the eventual clinical implementation of an implantable vestibular prosthesis.

  5. Occipital peripheral nerve stimulation in the management of chronic intractable occipital neuralgia in a patient with neurofibromatosis type 1: a case report.

    PubMed

    Skaribas, Ioannis; Calvillo, Octavio; Delikanaki-Skaribas, Evangelia

    2011-05-10

    Occipital peripheral nerve stimulation is an interventional pain management therapy that provides beneficial results in the treatment of refractory chronic occipital neuralgia. Herein we present a first-of-its-kind case study of a patient with neurofibromatosis type 1 and bilateral occipital neuralgia treated with occipital peripheral nerve stimulation. A 42-year-old Caucasian woman presented with bilateral occipital neuralgia refractory to various conventional treatments, and she was referred for possible treatment with occipital peripheral nerve stimulation. She was found to be a suitable candidate for the procedure, and she underwent implantation of two octapolar stimulating leads and a rechargeable, programmable, implantable generator. The intensity, severity, and frequency of her symptoms resolved by more than 80%, but an infection developed at the implantation site two months after the procedure that required explantation and reimplantation of new stimulating leads three months later. To date she continues to experience symptom resolution of more than 60%. These results demonstrate the significance of peripheral nerve stimulation in the management of refractory occipital neuralgias in patients with neurofibromatosis type 1 and the possible role of neurofibromata in the development of occipital neuralgia in these patients.

  6. Trace vanadium analysis by catalytic adsorptive stripping voltammetry using mercury-coated micro-wire and polystyrene-coated bismuth film electrodes

    PubMed Central

    Dansby-Sparks, Royce; Chambers, James Q.; Xue, Zi-Ling

    2009-01-01

    An electrochemical technique has been developed for ultra trace (ngL−1) vanadium (V) measurement. Catalytic adsorptive stripping voltammetry for V analysis was developed at mercury-coated gold micro-wire (MWE, 100 μm) electrodes in the presence of gallic acid (GA) and bromate ion. A potential of −0.275 V (vs Ag/AgCl) was used to accumulate the complex in acetate buffer (pH 5.0) at the electrode surface followed by a differential pulse voltammetric scan. Parameters affecting the electrochemical response, including pH, concentration of GA and bromate, deposition potential and time have been optimized. Linear response was obtained in the 0–1000 ngL−1 range (2 min deposition), with a detection limit of 0.88 ngL−1. The method was validated by comparison of results for an unknown solution of V by atomic absorption measurement. The protocol was evaluated in a real sample by measuring the amount of V in river water samples. Thick bismuth film electrodes with protective polystyrene films have also been made and evaluated as a mercury free alternative. However, ngL−1 level detection was only attainable with extended (10 min) deposition times. The proposed use of MWEs for the detection of V is sensitive enough for future use to test V concentration in biological fluids treated by the advanced oxidation process (AOP). PMID:19446059

  7. Time-varying metamaterials based on graphene-wrapped microwires: Modeling and potential applications

    NASA Astrophysics Data System (ADS)

    Salary, Mohammad Mahdi; Jafar-Zanjani, Samad; Mosallaei, Hossein

    2018-03-01

    The successful realization of metamaterials and metasurfaces requires the judicious choice of constituent elements. In this paper, we demonstrate the implementation of time-varying metamaterials in the terahertz frequency regime by utilizing graphene-wrapped microwires as building blocks and modulation of graphene conductivity through exterior electrical gating. These elements enable enhancement of light-graphene interaction by utilizing optical resonances associated with Mie scattering, yielding a large tunability and modulation depth. We develop a semianalytical framework based on transition-matrix formulation for modeling and analysis of periodic and aperiodic arrays of such time-varying building blocks. The proposed method is validated against full-wave numerical results obtained using the finite-difference time-domain method. It provides an ideal tool for mathematical synthesis and analysis of space-time gradient metamaterials, eliminating the need for computationally expensive numerical models. Moreover, it allows for a wider exploration of exotic space-time scattering phenomena in time-modulated metamaterials. We apply the method to explore the role of modulation parameters in the generation of frequency harmonics and their emerging wavefronts. Several potential applications of such platforms are demonstrated, including frequency conversion, holographic generation of frequency harmonics, and spatiotemporal manipulation of light. The presented results provide key physical insights to design time-modulated functional metadevices using various building blocks and open up new directions in the emerging paradigm of time-modulated metamaterials.

  8. Treatment of intractable chronic cluster headache by occipital nerve stimulation: a cohort of 51 patients.

    PubMed

    Miller, S; Watkins, L; Matharu, M

    2017-02-01

    Chronic cluster headache is a rare, highly disabling primary headache condition. When medically intractable, occipital nerve stimulation can offer effective treatment. Open-label series have provided data on small cohorts only. We analyzed 51 subjects to evaluate the long-term outcomes of highly intractable chronic cluster headache with occipital nerve stimulation. Patients with intractable chronic cluster headache were implanted with occipital nerve stimulators during the period 2007-2014. The primary endpoint was improvement in daily attack frequency. Secondary endpoints included attack severity, attack duration, quality-of-life measures, headache disability scores and adverse events. We studied 51 patients [35 males; mean age at implant 47.78 (range 31-70) years; mean follow-up 39.17 (range 2-81) months]. Nineteen patients had other chronic headache types in addition in chronic cluster headache. At final follow-up, there was a 46.1% improvement in attack frequency (P < 0001) across all patients, 49.5% (P < 0.001) in those with cluster headache alone and 40.3% (P = 0.036) in those with multiple phenotypes. There were no significant differences in response in those with or without multiple headache types. The overall response rate (defined as at least a 50% improvement in attack frequency) was 52.9%. Significant reductions were also seen in attack duration and severity. Improvements were noted in headache disability scores and quality-of-life measures. Triptan use of responders dropped by 62.56%, resulting in significant cost savings. Adverse event rates were highly favorable. Occipital nerve stimulation appears to be a safe and efficacious treatment for highly intractable chronic cluster headache even after a mean follow-up of over 3 years. © 2016 EAN.

  9. The effect of chronic intracortical microstimulation on the electrode-tissue interface.

    PubMed

    Chen, Kevin H; Dammann, John F; Boback, Jessica L; Tenore, Francesco V; Otto, Kevin J; Gaunt, Robert A; Bensmaia, Sliman J

    2014-04-01

    Somatosensation is critical for effective object manipulation, but current upper limb prostheses do not provide such feedback to the user. For individuals who require use of prosthetic limbs, this lack of feedback transforms a mundane task into one that requires extreme concentration and effort. Although vibrotactile motors and sensory substitution devices can be used to convey gross sensations, a direct neural interface is required to provide detailed and intuitive sensory feedback. The viability of intracortical microstimulation (ICMS) as a method to deliver feedback depends in part on the long-term reliability of implanted electrodes used to deliver the stimulation. The objective of the present study is to investigate the effects of chronic ICMS on the electrode-tissue interface. We stimulate the primary somatosensory cortex of three Rhesus macaques through chronically implanted electrodes for 4 h per day over a period of six months, with different electrodes subjected to different regimes of stimulation. We measure the impedance and voltage excursion as a function of time and of ICMS parameters. We also test the sensorimotor consequences of chronic ICMS by having animals grasp and manipulate small treats. We show that impedance and voltage excursion both decay with time but stabilize after 10-12 weeks. The magnitude of this decay is dependent on the amplitude of the ICMS and, to a lesser degree, the duration of individual pulse trains. Furthermore, chronic ICMS does not produce any deficits in fine motor control. The results suggest that chronic ICMS has only a minor effect on the electrode-tissue interface and may thus be a viable means to convey sensory feedback in neuroprosthetics.

  10. Cell-based neurotrophin treatment supports long-term auditory neuron survival in the deaf guinea pig.

    PubMed

    Gillespie, Lisa N; Zanin, Mark P; Shepherd, Robert K

    2015-01-28

    The cochlear implant provides auditory cues to profoundly deaf patients by electrically stimulating the primary auditory neurons (ANs) of the cochlea. However, ANs degenerate in deafness; the preservation of a robust AN target population, in combination with advances in cochlear implant technology, may provide improved hearing outcomes for cochlear implant patients. The exogenous delivery of neurotrophins such as brain-derived neurotrophic factor (BDNF) and neurotrophin-3 is well known to support AN survival in deafness, and cell-based therapies provide a potential clinically viable option for delivering neurotrophins into the deaf cochlea. This study utilized cells that were genetically modified to express BDNF and encapsulated in alginate microspheres, and investigated AN survival in the deaf guinea pig following (a) cell-based neurotrophin treatment in conjunction with chronic electrical stimulation from a cochlear implant, and (b) long-term cell-based neurotrophin delivery. In comparison to deafened controls, there was significantly greater AN survival following the cell-based neurotrophin treatment, and there were ongoing survival effects for at least six months. In addition, functional benefits were observed following cell-based neurotrophin treatment and chronic electrical stimulation, with a statistically significant decrease in electrically evoked auditory brainstem response thresholds observed during the experimental period. This study demonstrates that cell-based therapies, in conjunction with a cochlear implant, shows potential as a clinically transferable means of providing neurotrophin treatment to support AN survival in deafness. This technology also has the potential to deliver other therapeutic agents, and to be used in conjunction with other biomedical devices for the treatment of a variety of neurodegenerative conditions. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Incidence and Time Course for Developing Heart Failure With High-Burden Right Ventricular Pacing.

    PubMed

    Merchant, Faisal M; Hoskins, Michael H; Musat, Dan L; Prillinger, Julie B; Roberts, Gregory J; Nabutovsky, Yelena; Mittal, Suneet

    2017-06-01

    Although right ventricular pacing can contribute to cardiomyopathy, the impact of complete atrioventricular block (cAVB) on heart failure (HF) development in pacemaker patients has not been well characterized. We evaluated the incidence and time course for developing HF after pacemaker implantation for cAVB. A MarketScan database identified patients undergoing dual-chamber pacemaker implantation from 2008 to 2014. Patients with cAVB were identified by an atrioventricular node ablation or diagnosis of third-degree AVB. Patients with ≥1 year of continuous MarketScan enrollment before and after implant and without a previous diagnosis of HF were dichotomized into those with cAVB and without AVB. The primary end point was new HF assessed over acute (0-6 months) and chronic (6 months to 4 years) phases post-pacemaker implantation. The cohort included 6994 cAVB patients and 14 208 patients without AVB, followed for 2.35 years (interquartile range, 1.62-3.39 years). After adjustment for baseline covariates, patients with cAVB experienced an increased risk of new-onset HF in the acute phase (hazard ratio, 1.62; 95% confidence interval, 1.48-1.79; P <0.001). Although the risk of HF remained elevated among those with cAVB in the chronic phase, the effect was attenuated (hazard ratio, 1.16; 95% confidence interval, 1.08-1.25; P <0.001). After pacemaker implantation, younger patients (≤55 years of age) and those with an antecedent history of atrial fibrillation experienced the highest risk of HF associated with cAVB. Patients with a diagnosis of cAVB, and thus presumed to have a higher burden of right ventricular pacing, experienced an increased risk of new-onset HF after pacemaker implantation compared with those without AVB. Better tools are needed to identify patients at high risk of developing HF in the setting of right ventricular pacing and to determine whether these patients benefit from upfront biventricular pacing. © 2017 American Heart Association, Inc.

  12. Effect of defective collagen synthesis on epithelial implant interface: lathyritic model in dogs. An experimental preliminary study.

    PubMed

    Cengiz, Murat Inanç; Kirtiloğlu, Tuğrul; Acikgoz, Gökhan; Trisi, Paolo; Wang, Hom-Lay

    2012-04-01

    Peri-implant mucosa is composed of 2 compartments: a marginal junctional epithelium and a zone of connective tissue attachment. Both structures consist mainly of collagen. Lathyrism is characterized by defective collagen synthesis due to inhibition of lysyl oxidase, an enzyme that is essential for interfibrillar collagen cross-linking. The lathyritic agent beta-aminoproprionitrile (β-APN) is considered a suitable agent to disrupt the connective tissue metabolism. Therefore, the purpose of this study was to assess the effect of defective connective tissue metabolism on epithelial implant interface by using β-APN created chronic lathyrism in the canine model. Two 1-year-old male dogs were included in this study. A β-APN dosage of 5 mg/0.4 mL/volume 100 g/body weight was given to the test dog for 10 months, until lathyritic symptoms developed. After this, the mandibular premolar teeth (p2, p3, p4) of both dogs were atraumatically extracted, and the investigators waited 3 months before implants were placed. In the test dog, 3 implants were placed in the left mandible, and 2 implants were placed in the right mandible. In the control dog, 2 implants were placed in the left mandibular premolar site. The dogs were sacrificed 10 months after healing. Peri-implant tissues obtained from the dogs were examined histomorphologically and histopathologically. Bone to implant contact (BIC) values and bone volumes (BV) were lower in the lathyritic group compared to the control group; however, no statistical significance was found. Significant histologic and histomorphometric changes were observed in peri-implant bone, connective tissue, and peri-implant mucosal width between test and control implants. Defective collagen metabolism such as lathyrism may negatively influence the interface between implant and surrounding soft tissue attachment.

  13. Electronic enhancement of tear secretion

    NASA Astrophysics Data System (ADS)

    Brinton, Mark; Lim Chung, Jae; Kossler, Andrea; Kook, Koung Hoon; Loudin, Jim; Franke, Manfred; Palanker, Daniel

    2016-02-01

    Objective. To study electrical stimulation of the lacrimal gland and afferent nerves for enhanced tear secretion, as a potential treatment for dry eye disease. We investigate the response pathways and electrical parameters to safely maximize tear secretion. Approach. We evaluated the tear response to electrical stimulation of the lacrimal gland and afferent nerves in isofluorane-anesthetized rabbits. In acute studies, electrical stimulation was performed using bipolar platinum foil electrodes, implanted beneath the inferior lacrimal gland, and a monopolar electrode placed near the afferent ethmoid nerve. Wireless microstimulators with bipolar electrodes were implanted beneath the lacrimal gland for chronic studies. To identify the response pathways, we applied various pharmacological inhibitors. To optimize the stimulus, we measured tear secretion rate (Schirmer test) as a function of pulse amplitude (1.5-12 mA), duration (0.1-1 ms) and repetition rate (10-100 Hz). Main results. Stimulation of the lacrimal gland increased tear secretion by engaging efferent parasympathetic nerves. Tearing increased with stimulation amplitude, pulse duration and repetition rate, up to 70 Hz. Stimulation with 3 mA, 500 μs pulses at 70 Hz provided a 4.5 mm (125%) increase in Schirmer score. Modulating duty cycle further increased tearing up to 57%, compared to continuous stimulation in chronically implanted animals (36%). Ethmoid (afferent) nerve stimulation increased tearing similar to gland stimulation (3.6 mm) via a reflex pathway. In animals with chronically implanted stimulators, a nearly 6 mm increase (57%) was achieved with 12-fold less charge density per pulse (0.06-0.3 μC mm-2 with 170-680 μs pulses) than the damage threshold (3.5 μC mm-2 with 1 ms pulses). Significance. Electrical stimulation of the lacrimal gland or afferent nerves may be used as a treatment for dry eye disease. Clinical trials should validate this approach in patients with aqueous tear deficiency, and further optimize electrical parameters for maximum clinical efficacy.

  14. First report of 90-day support of 2 calves with a continuous-flow total artificial heart.

    PubMed

    Karimov, Jamshid H; Moazami, Nader; Kobayashi, Mariko; Sale, Shiva; Such, Kimberly; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Gao, Shengqiang; Kuban, Barry; Golding, Leonard A R; Fukamachi, Kiyotaka

    2015-09-01

    The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. CFTAH pumps have been implanted in 17 calves total. Hemodynamic parameters, pump performance, and device-related adverse events were evaluated during studies and at necropsy. In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure, 16 ± 3 mm Hg; right atrial pressure, 17 ± 3 mm Hg; right atrial pressure-left atrial pressure difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; and pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three animals with recent CFTAH implantation recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last 2 were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to human surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Evaluation of focused multipolar stimulation for cochlear implants: a preclinical safety study

    NASA Astrophysics Data System (ADS)

    Shepherd, Robert K.; Wise, Andrew K.; Enke, Ya Lang; Carter, Paul M.; Fallon, James B.

    2017-08-01

    Objective. Cochlear implants (CIs) have a limited number of independent stimulation channels due to the highly conductive nature of the fluid-filled cochlea. Attempts to develop highly focused stimulation to improve speech perception in CI users includes the use of simultaneous stimulation via multiple current sources. Focused multipolar (FMP) stimulation is an example of this approach and has been shown to reduce interaction between stimulating channels. However, compared with conventional biphasic current pulses generated from a single current source, FMP is a complex stimulus that includes extended periods of stimulation before charge recovery is achieved, raising questions on whether chronic stimulation with this strategy is safe. The present study evaluated the long-term safety of intracochlear stimulation using FMP in a preclinical animal model of profound deafness. Approach. Six cats were bilaterally implanted with scala tympani electrode arrays two months after deafening, and received continuous unilateral FMP stimulation at levels that evoked a behavioural response for periods of up to 182 d. Electrode impedance, electrically-evoked compound action potentials (ECAPs) and auditory brainstem responses (EABRs) were monitored periodically over the course of the stimulation program from both the stimulated and contralateral control cochleae. On completion of the stimulation program cochleae were examined histologically and the electrode arrays were evaluated for evidence of platinum (Pt) corrosion. Main results. There was no significant difference in electrode impedance between control and chronically stimulated electrodes following long-term FMP stimulation. Moreover, there was no significant difference between ECAP and EABR thresholds evoked from control or stimulated cochleae at either the onset of stimulation or at completion of the stimulation program. Chronic FMP stimulation had no effect on spiral ganglion neuron (SGN) survival when compared with unstimulated control cochleae. Long-term implantation typically evoked a mild foreign body reaction proximal to the electrode array; however stimulated cochleae exhibited a small but statistically significant increase in the tissue response. Finally, there was no evidence of Pt corrosion following long-term FMP stimulation; stimulated electrodes exhibited the same surface features as the unstimulated control electrodes. Significance. Chronic intracochlear FMP stimulation at levels used in the present study did not adversely affect electrically-evoked neural thresholds or SGN survival but evoked a small, benign increase in inflammatory response compared to control ears. Moreover chronic FMP stimulation does not affect the surface of Pt electrodes at suprathreshold stimulus levels. These findings support the safe clinical application of an FMP stimulation strategy.

  16. Pectoral nerves (PECS) and intercostal nerve block for cardiac resynchronization therapy device implantation.

    PubMed

    Fujiwara, Atsushi; Komasawa, Nobuyasu; Minami, Toshiaki

    2014-01-01

    A 71-year-old man was scheduled to undergo cardiac resynchronization therapy device (CRTD) implantation. He was combined with severe chronic heart failure due to ischemic heart disease. NYHA class was 3 to 4 and electrocardiogram showed non-sustained ventricular. Ejection fraction was about 20% revealed by transthoracic echocardiogram. He was also on several anticoagulation medications. We planned to implant the device under the greater pectoral muscle. As general anesthesia was considered risky, monitored anesthesia care utilizing peripheral nerve block and slight sedation was scheduled. Pectoral nerves (PECS) block and intercostal block was performed under ultrasonography with ropivacaine. For sedation during the procedure, continuous infusion of dexmedetomidine without a loading dose was performed. The procedure lasted about 3 hours, but the patient showed no pain or restlessness. Combination of PECS block and intercostal block may provide effective analgesia for CRTD implantation.

  17. Design and Evaluation of a Personal Digital Assistant-based Research Platform for Cochlear Implants

    PubMed Central

    Ali, Hussnain; Lobo, Arthur P.; Loizou, Philipos C.

    2014-01-01

    This paper discusses the design, development, features, and clinical evaluation of a personal digital assistant (PDA)-based platform for cochlear implant research. This highly versatile and portable research platform allows researchers to design and perform complex experiments with cochlear implants manufactured by Cochlear Corporation with great ease and flexibility. The research platform includes a portable processor for implementing and evaluating novel speech processing algorithms, a stimulator unit which can be used for electrical stimulation and neurophysio-logic studies with animals, and a recording unit for collecting electroencephalogram/evoked potentials from human subjects. The design of the platform for real time and offline stimulation modes is discussed for electric-only and electric plus acoustic stimulation followed by results from an acute study with implant users for speech intelligibility in quiet and noisy conditions. The results are comparable with users’ clinical processor and very promising for undertaking chronic studies. PMID:23674422

  18. Myocardial recovery during mechanical circulatory support: long-term outcome and elective ventricular assist device implantation to promote recovery as a treatment goal.

    PubMed

    Dandel, Michael; Hetzer, Roland

    2015-01-01

    Even after incomplete myocardial recovery during mechanical circulatory support, long-term survival rates after ventricular assist device (VAD) explantation can be better than those expected after heart transplantation even for patients with chronic non-ischemic cardiomyopathy as the underlying cause for VAD implantation. The elective therapeutic use of ventricular assist devices for heart failure reversal in its early stage is a future goal. It may be possible to achieve it by developing tools to predict heart failure reversibility even before ventricular assist device implantation and increasing the number of weaning candidates by improvement of adjunctive therapies to optimize unloading-promoted recovery.  Special attention is focused on the long-term stability of cardiac remission after VAD removal, the clinical relevance unloading-promoted myocardial recovery and on the current knowledge about a potential prediction of myocardial recovery during long-term VAD support already before VAD implantation.

  19. Toward biomaterial-based implantable photonic devices

    NASA Astrophysics Data System (ADS)

    Humar, Matjaž; Kwok, Sheldon J. J.; Choi, Myunghwan; Yetisen, Ali K.; Cho, Sangyeon; Yun, Seok-Hyun

    2017-03-01

    Optical technologies are essential for the rapid and efficient delivery of health care to patients. Efforts have begun to implement these technologies in miniature devices that are implantable in patients for continuous or chronic uses. In this review, we discuss guidelines for biomaterials suitable for use in vivo. Basic optical functions such as focusing, reflection, and diffraction have been realized with biopolymers. Biocompatible optical fibers can deliver sensing or therapeutic-inducing light into tissues and enable optical communications with implanted photonic devices. Wirelessly powered, light-emitting diodes (LEDs) and miniature lasers made of biocompatible materials may offer new approaches in optical sensing and therapy. Advances in biotechnologies, such as optogenetics, enable more sophisticated photonic devices with a high level of integration with neurological or physiological circuits. With further innovations and translational development, implantable photonic devices offer a pathway to improve health monitoring, diagnostics, and light-activated therapies.

  20. Use of antibiotic beads to salvage infected breast implants.

    PubMed

    Sherif, Rami D; Ingargiola, Michael; Sanati-Mehrizy, Paymon; Torina, Philip J; Harmaty, Marco A

    2017-10-01

    When an implant becomes infected, implant salvage is often performed where the implant is removed, capsulectomy is performed, and a new implant is inserted. The patient is discharged with a PICC line and 6-8 weeks of intravenous (IV) antibiotics. This method has variable success and subjects the patient to long-term systemic antibiotics. In the 1960s, the use of antibiotic-impregnated beads for the treatment of chronic osteomyelitis was described. These beads deliver antibiotic directly to the site of the infection, thereby eliminating the complications of systemic IV antibiotics. This study aimed to present a case series illustrating the use of STIMULAN calcium sulfate beads loaded with vancomycin and tobramycin to increase the rate of salvage of the infected implant and forgo IV antibiotics. A retrospective analysis was performed of patients who were treated at Mount Sinai Hospital for implant infection with salvage and antibiotic beads. Twelve patients were identified, 10 of whom had breast cancer. Comorbidities included hypertension, smoking, and immunocompromised status. Infections were noted anywhere from 5 days to 8 years postoperatively. Salvage was successful in 9 out of the 12 infected implants using antibiotic bead therapy without home IV antibiotics. The use of antibiotic beads is promising for salvaging infected breast implants without IV antibiotics. Seventy-five percent of the implants were successfully salvaged. Of the three patients who had unsalvageable implants, one was infected with antibiotic-resistant Rhodococcus that was refractory to bead therapy and one was noncompliant with postoperative instructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. The effects of chronic intracortical microstimulation on neural tissue and fine motor behavior.

    PubMed

    Rajan, Alexander T; Boback, Jessica L; Dammann, John F; Tenore, Francesco V; Wester, Brock A; Otto, Kevin J; Gaunt, Robert A; Bensmaia, Sliman J

    2015-12-01

    One approach to conveying sensory feedback in neuroprostheses is to electrically stimulate sensory neurons in the cortex. For this approach to be viable, it is critical that intracortical microstimulation (ICMS) causes minimal damage to the brain. Here, we investigate the effects of chronic ICMS on the neuronal tissue across a variety of stimulation regimes in non-human primates. We also examine each animal's ability to use their hand--the cortical representation of which is targeted by the ICMS--as a further assay of possible neuronal damage. We implanted electrode arrays in the primary somatosensory cortex of three Rhesus macaques and delivered ICMS four hours per day, five days per week, for six months. Multiple regimes of ICMS were delivered to investigate the effects of stimulation parameters on the tissue and behavior. Parameters included current amplitude (10-100 μA), pulse train duration (1, 5 s), and duty cycle (1/1, 1/3). We then performed a range of histopathological assays on tissue near the tips of both stimulated and unstimulated electrodes to assess the effects of chronic ICMS on the tissue and their dependence on stimulation parameters. While the implantation and residence of the arrays in the cortical tissue did cause significant damage, chronic ICMS had no detectable additional effect; furthermore, the animals exhibited no impairments in fine motor control. Chronic ICMS may be a viable means to convey sensory feedback in neuroprostheses as it does not cause significant damage to the stimulated tissue.

  2. The effects of chronic intracortical microstimulation on neural tissue and fine motor behavior

    NASA Astrophysics Data System (ADS)

    Rajan, Alexander T.; Boback, Jessica L.; Dammann, John F.; Tenore, Francesco V.; Wester, Brock A.; Otto, Kevin J.; Gaunt, Robert A.; Bensmaia, Sliman J.

    2015-12-01

    Objective. One approach to conveying sensory feedback in neuroprostheses is to electrically stimulate sensory neurons in the cortex. For this approach to be viable, it is critical that intracortical microstimulation (ICMS) causes minimal damage to the brain. Here, we investigate the effects of chronic ICMS on the neuronal tissue across a variety of stimulation regimes in non-human primates. We also examine each animal’s ability to use their hand—the cortical representation of which is targeted by the ICMS—as a further assay of possible neuronal damage. Approach. We implanted electrode arrays in the primary somatosensory cortex of three Rhesus macaques and delivered ICMS four hours per day, five days per week, for six months. Multiple regimes of ICMS were delivered to investigate the effects of stimulation parameters on the tissue and behavior. Parameters included current amplitude (10-100 μA), pulse train duration (1, 5 s), and duty cycle (1/1, 1/3). We then performed a range of histopathological assays on tissue near the tips of both stimulated and unstimulated electrodes to assess the effects of chronic ICMS on the tissue and their dependence on stimulation parameters. Main results. While the implantation and residence of the arrays in the cortical tissue did cause significant damage, chronic ICMS had no detectable additional effect; furthermore, the animals exhibited no impairments in fine motor control. Significance. Chronic ICMS may be a viable means to convey sensory feedback in neuroprostheses as it does not cause significant damage to the stimulated tissue.

  3. [Complications of intrathecal baclofen therapy].

    PubMed

    Paskhin, D L; Dekopov, A V; Tomsky, A A; Isagulyan, E D; Salova, E M

    To analyze complications of intrathecal baclofen therapy and identify high-risk groups. We implanted 52 pumps to spastic patients for chronic intrathecal baclofen infusion. Two groups of patients were distinguished: 23 patients with spinal spasticity (group 1) and 29 patients with cerebral spasticity (group 2). The mean patient age was 37.2±14.6 years in group 1 and 17.3±10.3 years in group 2. Surgery was performed according to a standard procedure. A Medstream (Codman) pump was implanted in 10 cases, and a Synchromed II (Medtronic) pump was implanted in the remaining 42 cases. Complications developed in 12 (23%) patients. We divided complications into 3 groups: baclofen underdose, baclofen overdose, and others. Insufficiency of intrathecal therapy was observed in 7 cases, which was caused by catheter migration (5 cases) and pump dysfunction (2 cases). In one case, baclofen overdose was observed after air travel. Other complications included 4 cases of persistent peri-implant seroma and infectious complications. Groups with a high risk of complications were identified based on an analysis of the results. Patients with severe dystonia of the trunk muscles have an increased risk of spinal catheter migration. Pronounced communicating hydrocephalus is associated with the risk of cerebrospinal fluid leak through a catheter shaft channel. Weakness of the axial musculature can lead to progression of scoliotic deformity. In some cases, chronic intrathecal baclofen therapy can be accompanied by various complications. This technique should be carefully used in patients from high-risk groups.

  4. Wireless implantable electronic platform for chronic fluorescent-based biosensors.

    PubMed

    Valdastri, Pietro; Susilo, Ekawahyu; Förster, Thilo; Strohhöfer, Christof; Menciassi, Arianna; Dario, Paolo

    2011-06-01

    The development of a long-term wireless implantable biosensor based on fluorescence intensity measurement poses a number of technical challenges, ranging from biocompatibility to sensor stability over time. One of these challenges is the design of a power efficient and miniaturized electronics, enabling the biosensor to move from bench testing to long term validation, up to its final application in human beings. In this spirit, we present a wireless programmable electronic platform for implantable chronic monitoring of fluorescent-based autonomous biosensors. This system is able to achieve extremely low power operation with bidirectional telemetry, based on the IEEE802.15.4-2003 protocol, thus enabling over three-year battery lifetime and wireless networking of multiple sensors. During the performance of single fluorescent-based sensor measurements, the circuit drives a laser diode, for sensor excitation, and acquires the amplified signals from four different photodetectors. In vitro functionality was preliminarily tested for both glucose and calcium monitoring, simply by changing the analyte-binding protein of the biosensor. Electronics performance was assessed in terms of timing, power consumption, tissue exposure to electromagnetic fields, and in vivo wireless connectivity. The final goal of the presented platform is to be integrated in a complete system for blood glucose level monitoring that may be implanted for at least one year under the skin of diabetic patients. Results reported in this paper may be applied to a wide variety of biosensors based on fluorescence intensity measurement.

  5. Sensorimotor-correlated discharge recorded from ensembles of cerebellar Purkinje cells varies across the estrous cycle of the rat.

    PubMed

    Smith, S S

    1995-09-01

    1. In the present study, locomotor-correlated activity of cerebellar Purkinje cells, recorded using arrays of microwires chronically implanted in adult female rats, was examined across estrous-cycle-associated fluctuations in endogenous sex steroids. Ongoing studies from this laboratory have shown that systemic and local administration of the sex steroid 17 beta-estradiol (E2) augments excitatory responses of cerebellar Purkinje cells to iontophoretically applied glutamate, recorded in vivo from anesthetized female rats. In addition, this steroid potentiated discharge correlated with limb movement. For the present study, extracellular single-unit activity was recorded from as many as 5-11 Purkinje cells simultaneously during treadmill locomotion paradigms. Motor modulation of activity was recorded across three to five consecutive estrous cycles from behaviorally identified cohorts of neurons to test the hypothesis that fluctuations in endogenous sex steroids alter motor modulation of Purkinje cell discharge. 2. Locomotor-associated discharge correlated with treadmill locomotion was increased by a mean of 47% on proestrus, when E2 levels are elevated, relative to diestrus 1. These changes in discharge rate during treadmill locomotion were of significantly greater magnitude than corresponding cyclic alterations in discharge during stationary periods. 3. Correlations with the circadian cycle were also significant, because peak levels of locomotor-associated discharge on the night of behavioral estrus, following elevations in circulating E2, were on average 67% greater than corresponding discharge recorded during the light (proestrus). 4. Alterations in the step cycle were also observed across the estrous cycle: significant decreases in the duration of the flexion phase (by 265 ms, P < 0.05) were noted on estrus compared with diestrus. 5. When recorded on estrus, Purkinje cell discharge correlated with the stance or flexion phase of the step cycle was greater in magnitude and preceded the event by an average of 130 ms, compared with values determined on diestrus. 6. On estrus, responses of Purkinje neurons to iontophoretically applied quisqualate were enhanced fourfold after administration of exogenous E2, assessed in urethan-anesthetized female rats. 7. In addition, systemic administration of E2 (30 ng iv) potentiated responses of cerebellar Purkinje cells to electrical stimulation of the forepaw by an average of 150%, recorded in anesthetized female rats. 8. These results are consistent with the hypothesis that elevations in circulating E2 are associated with enhanced discharge of cerebellar Purkinje cells in response to pharmacological or electrical stimuli or associated with locomotor behavior.

  6. Cross-linked xenogenic collagen implantation in the sheep model for vaginal surgery.

    PubMed

    Endo, Masayuki; Urbankova, Iva; Vlacil, Jaromir; Sengupta, Siddarth; Deprest, Thomas; Klosterhalfen, Bernd; Feola, Andrew; Deprest, Jan

    The properties of meshes used in reconstructive surgery affect the host response and biomechanical characteristics of the grafted tissue. Whereas durable synthetics induce a chronic inflammation, biological grafts are usually considered as more biocompatible. The location of implantation is another determinant of the host response: the vagina is a different environment with specific function and anatomy. Herein, we evaluated a cross-linked acellular collagen matrix (ACM), pretreated by the anti-calcification procedure ADAPT® in a sheep model for vaginal surgery. Ten sheep were implanted with a cross-linked ACM, and six controls were implanted with a polypropylene (PP; 56 g/m 2 ) control. One implant was inserted in the lower rectovaginal septum, and one was used for abdominal wall defect reconstruction. Grafts were removed after 180 days; all graft-related complications were recorded, and explants underwent bi-axial tensiometry and contractility testing. Half of ACM-implanted animals had palpable induration in the vaginal implantation area, two of these also on the abdominal implant. One animal had a vaginal exposure. Vaginal ACMs were 63 % less stiff compared to abdominal ACM explants ( p  = 0.01) but comparable to vaginal PP explants. Seven anterior vaginal ACM explants showed areas of graft degradation on histology. There was no overall difference in vaginal contractility. Considering histologic degradation in the anterior vaginal implant as representative for the host, posterior ACM explants of animals with degradation had a 60 % reduced contractility as compared to PP ( p  = 0.048). Three abdominal implants showed histologic degradation; those were more compliant than non-degraded implants. Vaginal implantation with ACM was associated with graft-related complications (GRCs) and biomechanical properties comparable to PP. Partially degraded ACM had a decreased vaginal contractility.

  7. Behavioral and cellular consequences of high-electrode count Utah Arrays chronically implanted in rat sciatic nerve.

    PubMed

    Wark, H A C; Mathews, K S; Normann, R A; Fernandez, E

    2014-08-01

    Before peripheral nerve electrodes can be used for the restoration of sensory and motor functions in patients with neurological disorders, the behavioral and histological consequences of these devices must be investigated. These indices of biocompatibility can be defined in terms of desired functional outcomes; for example, a device may be considered for use as a therapeutic intervention if the implanted subject retains functional neurons post-implantation even in the presence of a foreign body response. The consequences of an indwelling device may remain localized to cellular responses at the device-tissue interface, such as fibrotic encapsulation of the device, or they may affect the animal more globally, such as impacting behavioral or sensorimotor functions. The objective of this study was to investigate the overall consequences of implantation of high-electrode count intrafascicular peripheral nerve arrays, High Density Utah Slanted Electrode Arrays (HD-USEAs; 25 electrodes mm(-2)). HD-USEAs were implanted in rat sciatic nerves for one and two month periods. We monitored wheel running, noxious sensory paw withdrawal reflexes, footprints, nerve morphology and macrophage presence at the tissue-device interface. In addition, we used a novel approach to contain the arrays in actively behaving animals that consisted of an organic nerve wrap. A total of 500 electrodes were implanted across all ten animals. The results demonstrated that chronic implantation (⩽8 weeks) of HD-USEAs into peripheral nerves can evoke behavioral deficits that recover over time. Morphology of the nerve distal to the implantation site showed variable signs of nerve fiber degeneration and regeneration. Cytology adjacent to the device-tissue interface also showed a variable response, with some electrodes having many macrophages surrounding the electrodes, while other electrodes had few or no macrophages present. This variability was also seen along the length of the electrodes. Axons remained within the proximity of the electrode tips at the distances required for theoretically effective stimulation and recording (⩽100 μm). We conclude from these studies that HD-USEAs do not cause overall global effects on the animals, at least up to the two-month period investigated here. These results demonstrate for the first time that the consequences of high-electrode count intrafascicular arrays compare with other peripheral nerve electrodes currently available for clinical or investigational neuromodulation.

  8. Behavioral and cellular consequences of high-electrode count Utah Arrays chronically implanted in rat sciatic nerve

    NASA Astrophysics Data System (ADS)

    Wark, H. A. C.; Mathews, K. S.; Normann, R. A.; Fernandez, E.

    2014-08-01

    Objective. Before peripheral nerve electrodes can be used for the restoration of sensory and motor functions in patients with neurological disorders, the behavioral and histological consequences of these devices must be investigated. These indices of biocompatibility can be defined in terms of desired functional outcomes; for example, a device may be considered for use as a therapeutic intervention if the implanted subject retains functional neurons post-implantation even in the presence of a foreign body response. The consequences of an indwelling device may remain localized to cellular responses at the device-tissue interface, such as fibrotic encapsulation of the device, or they may affect the animal more globally, such as impacting behavioral or sensorimotor functions. The objective of this study was to investigate the overall consequences of implantation of high-electrode count intrafascicular peripheral nerve arrays, High Density Utah Slanted Electrode Arrays (HD-USEAs; 25 electrodes mm-2). Approach. HD-USEAs were implanted in rat sciatic nerves for one and two month periods. We monitored wheel running, noxious sensory paw withdrawal reflexes, footprints, nerve morphology and macrophage presence at the tissue-device interface. In addition, we used a novel approach to contain the arrays in actively behaving animals that consisted of an organic nerve wrap. A total of 500 electrodes were implanted across all ten animals. Main results. The results demonstrated that chronic implantation (⩽8 weeks) of HD-USEAs into peripheral nerves can evoke behavioral deficits that recover over time. Morphology of the nerve distal to the implantation site showed variable signs of nerve fiber degeneration and regeneration. Cytology adjacent to the device-tissue interface also showed a variable response, with some electrodes having many macrophages surrounding the electrodes, while other electrodes had few or no macrophages present. This variability was also seen along the length of the electrodes. Axons remained within the proximity of the electrode tips at the distances required for theoretically effective stimulation and recording (⩽100 μm). Significance. We conclude from these studies that HD-USEAs do not cause overall global effects on the animals, at least up to the two-month period investigated here. These results demonstrate for the first time that the consequences of high-electrode count intrafascicular arrays compare with other peripheral nerve electrodes currently available for clinical or investigational neuromodulation.

  9. [Postoperative Follow-Up of Glaucoma Drainage Devices].

    PubMed

    Dietlein, T S; Neugebauer, A; Fricke, J; Lappas, A; Rosentreter, A

    2016-05-01

    There is an increasing trend towards using glaucoma drainage implants. The postoperative management of such devices depends on their technical characteristics and specific complications. The Baerveldt glaucoma implant with its larger surface area has been shown to lower mean intraocular pressure more effectively than the Ahmed-FP7 implant. As a non-valve implant, however, it has been associated with a higher rate of severe complications, particularly ocular hypotension. Moreover, glaucoma implants may induce diplopia if they interfere with extraocular muscles. Topical treatment with antibiotics and steroids is necessary in cases of intraocular inflammation. In refractory cases, the tube may even have to be removed. Surgical reposition of the tube may be indicated when it is severely dislocated. Increased intraocular pressure is primarily treated by pressure-lowering medications during postoperative follow-up. If topical glaucoma medication is insufficient to control increases in intraocular pressure due to encapsulation, a second implant may be considered or the capsule surrounding the implant may be excised to reduce outflow resistance or additional cyclodestructive procedures can be performed. Chronic hypotension may be treated with tube ligation or occlusion. Severe corneal oedema may require lamellar keratoplasty. Conjunctival erosions with tube exposure or tube retractions also require surgical correction. Georg Thieme Verlag KG Stuttgart · New York.

  10. Decoronation followed by dental implants placement: fundamentals, applications and explanations

    PubMed Central

    Consolaro, Alberto; Ribeiro, Paulo Domingos; Cardoso, Maurício A.; Miranda, Dario A. Oliveira; Salfatis, Monica

    2018-01-01

    ABSTRACT Dental arches areas with teeth presenting dentoalveolar ankylosis and replacement root resorption can be considered as presenting normal bone, in full physiological remodeling process; and osseointegrated implants can be successfully placed. Bone remodeling will promote osseointegration, regardless of presenting ankylosis and/or replacement root resorption. After 1 to 10 years, all dental tissues will have been replaced by bone. The site, angulation and ideal positioning in the space to place the implant should be dictated exclusively by the clinical convenience, associated with previous planning. One of the advantages of decoronation followed by dental implants placement in ankylosed teeth with replacement resorption is the maintenance of bone volume in the region, both vertical and horizontal. If possible, the buccal part of the root, even if thin, should be preserved in the preparation of the cavity for the implant, as this will maintain gingival tissues looking fully normal for long periods. In the selection of cases for decoronation, the absence of microbial contamination in the region - represented by chronic periapical lesions, presence of fistula, old unconsolidated root fractures and active advanced periodontal disease - is important. Such situations are contraindications to decoronation. However, the occurrence of dentoalveolar ankylosis and replacement resorption without contamination should neither change the planning for implant installation, nor the criteria for choosing the type and brand of dental implant to be used. Failure to decoronate and use dental implants has never been reported. PMID:29791693

  11. Anaplastic large cell lymphoma (ALCL) and breast implants: breaking down the evidence.

    PubMed

    Ye, Xuan; Shokrollahi, Kayvan; Rozen, Warren M; Conyers, Rachel; Wright, Penny; Kenner, Lukas; Turner, Suzanne D; Whitaker, Iain S

    2014-01-01

    Systemic anaplastic large cell lymphoma (ALCL) is a distinct disease classification provisionally sub-divided into ALCL, Anaplastic Lymphoma Kinase (ALK)(+) and ALCL, ALK(-) entities. More recently, another category of ALCL has been increasingly reported in the literature and is associated with the presence of breast implants. A comprehensive review of the 71 reported cases of breast implant associated ALCL (iALCL) is presented indicating the apparent risk factors and main characteristics of this rare cancer. The average patient is 50 years of age and most cases present in the capsule surrounding the implant as part of the periprosthetic fluid or the capsule itself on average at 10 years post-surgery suggesting that iALCL is a late complication. The absolute risk is low ranging from 1:500,000 to 1:3,000,000 patients with breast implants per year. The majority of cases are ALK-negative, yet are associated with silicone-coated implants suggestive of the mechanism of tumorigenesis which is discussed in relation to chronic inflammation, immunogenicity of the implants and sub-clinical infection. In particular, capsulotomy alone seems to be sufficient for the treatment of many cases suggesting the implants provide the biological stimulus whereas others require further treatment including chemo- and radiotherapy although reported cases remain too low to recommend a therapeutic approach. However, CD30-based therapeutics might be a future option. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. A review on mechanical considerations for chronically-implanted neural probes

    NASA Astrophysics Data System (ADS)

    Lecomte, Aziliz; Descamps, Emeline; Bergaud, Christian

    2018-06-01

    This review intends to present a comprehensive analysis of the mechanical considerations for chronically-implanted neural probes. Failure of neural electrical recordings or stimulation over time has shown to arise from foreign body reaction and device material stability. It seems that devices that match most closely with the mechanical properties of the brain would be more likely to reduce the mechanical stress at the probe/tissue interface, thus improving body acceptance. The use of low Young’s modulus polymers instead of hard substrates is one way to enhance this mechanical mimetism, though compliance can be achieved through a variety of means. The reduction of probe width and thickness in comparison to a designated length, the use of soft hydrogel coatings and the release in device tethering to the skull, can also improve device compliance. Paradoxically, the more compliant the device, the more likely it will fail during the insertion process in the brain. Strategies have multiplied this past decade to offer partial or temporary stiffness to the device to overcome this buckling effect. A detailed description of the probe insertion mechanisms is provided to analyze potential sources of implantation failure and the need for a mechanically-enhancing structure. This leads us to present an overview of the strategies that have been put in place over the last ten years to overcome buckling issues. Particularly, great emphasis is put on bioresorbable polymers and their assessment for neural applications. Finally, a discussion is provided on some of the key features for the design of mechanically-reliable, polymer-based next generation of chronic neuroprosthetic devices.

  13. In vivo biocompatibility of boron doped and nitrogen included conductive-diamond for use in medical implants.

    PubMed

    Garrett, David J; Saunders, Alexia L; McGowan, Ceara; Specks, Joscha; Ganesan, Kumaravelu; Meffin, Hamish; Williams, Richard A; Nayagam, David A X

    2016-01-01

    Recently, there has been interest in investigating diamond as a material for use in biomedical implants. Diamond can be rendered electrically conducting by doping with boron or nitrogen. This has led to inclusion of boron doped and nitrogen included diamond elements as electrodes and/or feedthroughs for medical implants. As these conductive device elements are not encapsulated, there is a need to establish their clinical safety for use in implants. This article compares the biocompatibility of electrically conducting boron doped diamond (BDD) and nitrogen included diamond films and electrically insulating poly crystalline diamond films against a silicone negative control and a BDD sample treated with stannous octoate as a positive control. Samples were surgically implanted into the back muscle of a guinea pig for a period of 4-15 weeks, excised and the implant site sectioned and submitted for histological analysis. All forms of diamond exhibited a similar or lower thickness of fibrotic tissue encapsulating compared to the silicone negative control samples. All forms of diamond exhibited similar or lower levels of acute, chronic inflammatory, and foreign body responses compared to the silicone negative control indicating that the materials are well tolerated in vivo. © 2015 Wiley Periodicals, Inc.

  14. In vivo Characterization of Amorphous Silicon Carbide As a Biomaterial for Chronic Neural Interfaces

    PubMed Central

    Knaack, Gretchen L.; McHail, Daniel G.; Borda, German; Koo, Beomseo; Peixoto, Nathalia; Cogan, Stuart F.; Dumas, Theodore C.; Pancrazio, Joseph J.

    2016-01-01

    Implantable microelectrode arrays (MEAs) offer clinical promise for prosthetic devices by enabling restoration of communication and control of artificial limbs. While proof-of-concept recordings from MEAs have been promising, work in animal models demonstrates that the obtained signals degrade over time. Both material robustness and tissue response are acknowledged to have a role in device lifetime. Amorphous Silicon carbide (a-SiC), a robust material that is corrosion resistant, has emerged as an alternative encapsulation layer for implantable devices. We systematically examined the impact of a-SiC coating on Si probes by immunohistochemical characterization of key markers implicated in tissue-device response. After implantation, we performed device capture immunohistochemical labeling of neurons, astrocytes, and activated microglia/macrophages after 4 and 8 weeks of implantation. Neuron loss and microglia activation were similar between Si and a-SiC coated probes, while tissue implanted with a-SiC displayed a reduction in astrocytes adjacent to the probe. These results suggest that a-SiC has a similar biocompatibility profile as Si, and may be suitable for implantable MEA applications as a hermetic coating to prevent material degradation. PMID:27445672

  15. Polyimide-based intracortical neural implant with improved structural stiffness

    NASA Astrophysics Data System (ADS)

    Lee, Kee-Keun; He, Jiping; Singh, Amarjit; Massia, Stephen; Ehteshami, Gholamreza; Kim, Bruce; Raupp, Gregory

    2004-01-01

    A novel structure for chronically implantable cortical electrodes using polyimide bio-polymer was devised, which provides both flexibility for micro-motion compliance between brain tissues and the skull and at the brain/implant interface and stiffness for better surgical handling. A 5-10 µm thick silicon backbone layer was attached to the tip of the electrode to enhance the structural stiffness. This stiff segment was then followed by a 1 mm flexible segment without a silicon backbone layer. The fabricated implants have tri-shanks with five recording sites (20 µm × 20 µm) and two vias of 40 µm × 40 µm on each shank. In vitro cytotoxicity tests of prototype implants revealed no adverse toxic effects on cells. Bench test impedance values were assessed, resulting in an average impedance value of ~2 MOmega at 1 KHz. For a 5 µm thick silicon backbone electrode, the stiffness of polyimide-based electrodes was increased ten times over that of electrodes without the silicon backbone layer. Furthermore, polyimide-based electrodes with 5 µm and 10 µm thick silicon backbone layer penetrated pia of rat brain without buckling that has been observed in implants without silicon reinforcement.

  16. Inflammatory reaction to fabric collars from percutaneous antennas attached to intracoelomic radio transmitters implanted in harlequin ducks (Histrionicus histrionicus)

    USGS Publications Warehouse

    Mulcahy, Daniel M.; Burek, K.A.; Esler, Daniel N.

    2007-01-01

    In wild birds implanted intracoelomically with radio transmitters, a synthetic fabric collar placed around the base of a percutaneous antenna is believed to function as a barrier to contamination of the coelom. We examined 13 fabric collars recovered from percutaneous antennas of radio transmitters implanted intracoelomically in harlequin ducks (Histrionicus histrionicus) 12 months earlier. Both the transmitters and antenna collars were encapsulated in fibrous connective tissue, with adhesions to internal organs. Histologically, bacteria were evident at the fabric-plastic interface in 8 of 10 collars examined in cross section and along the length of the collar in 3 collars examined longitudinally. Bacteria were confined within the fibrotic sheath surrounding the transmitter and the antenna collar in all birds. No evidence of chronic systemic effects secondary to implantation was present on hematologic or serum biochemical testing. These findings indicate that antenna collars do not prevent the entry of bacteria along the percutaneous antenna but may help stabilize the antenna and minimize coelomic contamination. We conclude that radio transmitters implanted into the coelom of harlequin ducks do not appear to cause significant health problems for at least 1 year after implantation.

  17. In vivo Characterization of Amorphous Silicon Carbide As a Biomaterial for Chronic Neural Interfaces.

    PubMed

    Knaack, Gretchen L; McHail, Daniel G; Borda, German; Koo, Beomseo; Peixoto, Nathalia; Cogan, Stuart F; Dumas, Theodore C; Pancrazio, Joseph J

    2016-01-01

    Implantable microelectrode arrays (MEAs) offer clinical promise for prosthetic devices by enabling restoration of communication and control of artificial limbs. While proof-of-concept recordings from MEAs have been promising, work in animal models demonstrates that the obtained signals degrade over time. Both material robustness and tissue response are acknowledged to have a role in device lifetime. Amorphous Silicon carbide (a-SiC), a robust material that is corrosion resistant, has emerged as an alternative encapsulation layer for implantable devices. We systematically examined the impact of a-SiC coating on Si probes by immunohistochemical characterization of key markers implicated in tissue-device response. After implantation, we performed device capture immunohistochemical labeling of neurons, astrocytes, and activated microglia/macrophages after 4 and 8 weeks of implantation. Neuron loss and microglia activation were similar between Si and a-SiC coated probes, while tissue implanted with a-SiC displayed a reduction in astrocytes adjacent to the probe. These results suggest that a-SiC has a similar biocompatibility profile as Si, and may be suitable for implantable MEA applications as a hermetic coating to prevent material degradation.

  18. Inadvertent transposition of defibrillator coil terminal pins causing inappropriate ICD therapies.

    PubMed

    Issa, Ziad F

    2008-06-01

    We report the case of a 65-year-old man with chronic atrial fibrillation (AF) and severe ischemic cardiomyopathy who underwent implantation of a prophylactic single-chamber implantable cardioverter-defibrillator (ICD). The patient experienced inappropriate ICD therapies due to oversensing of pectoral muscle myopotential secondary to reversal of the defibrillator coil terminal pins in the ICD header. Recognizing this possibility is important to avoid misinterpretation of spontaneous oversensing as hardware failure (e.g., lead fracture or insulation breech) and potentially unnecessary ICD system surgical intervention, including lead extraction.

  19. Multi-layered Poly-Dimethylsiloxane As A Non-Hermetic Packaging Material For Medical MEMS

    PubMed Central

    Lachhman, S.; Zorman, C.A.; Ko, W.H.

    2012-01-01

    Poly-dimethylsiloxane (PDMS) is an attractive material for packaging implantable biomedical microdevices owing to its biocompatibility, ease in application, and bio-friendly mechanical properties. Unfortunately, devices encapsulated by PDMS lack the longevity for use in chronic implant applications due to defect-related moisture penetration through the packaging layer. This paper describes an effort to improve the performance of PDMS as packaging material by constructing the encapsulant from multiple, thin layers of PDMS as a part of a polymeric multi-material package PMID:23366225

  20. Immediate implants placed in fresh sockets associated to periapical infectious processes. A systematic review

    PubMed Central

    Álvarez-Camino, Juan C.; Valmaseda-Castellón, Eduard

    2013-01-01

    Objetives: The development of treated implant surfaces, added to the increase of the aesthetic requirements by the patients has led to a change in the treatment protocols as well as the development of techniques such as the one-fase implants and the immediate prosthetic loading. One of the usual contraindications of the implant treatment is the presence of periapical disease associated to the tooth to be replaced. The aim of this paper is to review the published literature on immediate implant placement in extraction sockets of teeth with periapical pathology, considering the level of scientific evidence, and following the principles of medicine and evidence-based Dentistry. Material and Methods: A search of articles published between 1982 and 2012 was conducted. The search terms immediate, dental implant, extraction, infected, periapical pathology were used. Search was limited to studies in animals and humans, published in english language. Results: 16 articles were selected from a total of 438, which were stratified according to their level of scientific evidence using the SORT criteria (Strength of Recommendation Taxonomy). Studies in both animals and humans presented high rates of implant survival, but human studies are limited to a small number of cases. Discussion and Conclusions: There is a limited evidence regarding implant placement immediately to the extraction of teeth affected by chronic periapical pathology. Following analysis of the articles, and in function of their scientific quality, a type B recommendation is given in favor of the immediate implant placement in fresh sockets associated to periapical infectious processes. Key words:Immediate implant, periapical pathology. PMID:23722139

  1. Silicone-specific blood lymphocyte response in women with silicone breast implants.

    PubMed Central

    Ojo-Amaize, E A; Conte, V; Lin, H C; Brucker, R F; Agopian, M S; Peter, J B

    1994-01-01

    A blinded cross-sectional study was carried out with 99 women, 44 of whom had silicone breast implants. Group I consisted of 55 healthy volunteer women without breast implants; group II comprised 13 volunteer women with breast implants or explants who felt healthy; group III comprised 21 volunteer women with breast implants who had chronic fatigue, musculoskeletal symptoms, and skin disorders; and group IV comprised 10 women who had their prostheses explanted but still presented with clinical symptoms similar to those of the women in group III. Proliferative responses of peripheral blood mononuclear cells from all 99 women were measured by [3H]thymidine uptake after exposure to SiO2 silicon, or silicone gel. The levels of proliferative responses were expressed as stimulation indices, which were obtained by dividing the counts per minute of stimulated cells by the counts per minute of unstimulated cells. Abnormal responses to SiO2, silicon, or silicone gel were defined as a stimulation index of > 2.8, > 2.1, or > 2.4, respectively. Abnormal responses were observed in 0% of group I, 15% of group II, 29% of group III, and 30% of group IV (P < 0.0005 for group I versus groups II and IV). Thirty-one percent of symptomatic women with silicone gel breast implants had elevated serum silicon levels ( > 0.18 mg/liter); however, there was no significant correlation between abnormal cellular responses and silicon levels in blood serum, type of implant, time since first implantation, prosthesis explantation, number of implants, or report of implant leakage or rupture.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8556522

  2. Chronic cortical and electromyographic recordings from a fully implantable device: preclinical experience in a nonhuman primate

    NASA Astrophysics Data System (ADS)

    Ryapolova-Webb, Elena; Afshar, Pedram; Stanslaski, Scott; Denison, Tim; de Hemptinne, Coralie; Bankiewicz, Krystof; Starr, Philip A.

    2014-02-01

    Objective. Analysis of intra- and perioperatively recorded cortical and basal ganglia local field potentials in human movement disorders has provided great insight into the pathophysiology of diseases such as Parkinson's, dystonia, and essential tremor. However, in order to better understand the network abnormalities and effects of chronic therapeutic stimulation in these disorders, long-term recording from a fully implantable data collection system is needed. Approach. A fully implantable investigational data collection system, the Activa® PC + S neurostimulator (Medtronic, Inc., Minneapolis, MN), has been developed for human use. Here, we tested its utility for extended intracranial recording in the motor system of a nonhuman primate. The system was attached to two quadripolar paddle arrays: one covering sensorimotor cortex, and one covering a proximal forelimb muscle, to study simultaneous cortical field potentials and electromyography during spontaneous transitions from rest to movement. Main results. Over 24 months of recording, movement-related changes in physiologically relevant frequency bands were readily detected, including beta and gamma signals at approximately 2.5 μV/\\sqrtHz and 0.7 μV/\\sqrt{Hz}, respectively. The system architecture allowed for flexible recording configurations and algorithm triggered data recording. In the course of physiological analyses, sensing artifacts were observed (˜1 μVrms stationary tones at fixed frequency), which were mitigated either with post-processing or algorithm design and did not impact the scientific conclusions. Histological examination revealed no underlying tissue damage; however, a fibrous capsule had developed around the paddles, demonstrating a potential mechanism for the observed signal amplitude reduction. Significance. This study establishes the usefulness of this system in measuring chronic brain and muscle signals. Use of this system may potentially be valuable in human trials of chronic brain recording in movement disorders, a next step in the design of closed-loop neurostimulation paradigms.

  3. Evaluating the in vivo glial response to miniaturized parylene cortical probes coated with an ultra-fast degrading polymer to aid insertion

    NASA Astrophysics Data System (ADS)

    Lo, Meng-chen; Wang, Shuwu; Singh, Sagar; Damodaran, Vinod B.; Ahmed, Ijaz; Coffey, Kevin; Barker, David; Saste, Kshitij; Kals, Karanvir; Kaplan, Hilton M.; Kohn, Joachim; Shreiber, David I.; Zahn, Jeffrey D.

    2018-06-01

    Objective. Despite the feasibility of short-term neural recordings using implantable microelectrodes, attaining reliable, chronic recordings remains a challenge. Most neural recording devices suffer from a long-term tissue response, including gliosis, at the device–tissue interface. It was hypothesized that smaller, more flexible intracortical probes would limit gliosis by providing a better mechanical match with surrounding tissue. Approach. This paper describes the in vivo evaluation of flexible parylene microprobes designed to improve the interface with the adjacent neural tissue to limit gliosis and thereby allow for improved recording longevity. The probes were coated with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)) polymer that provides temporary mechanical support for device implantation, yet degrades within 2 h post-implantation. A parametric study of probes of varying dimensions and polymer coating thicknesses were implanted in rat brains. The glial tissue response and neuronal loss were assessed from 72 h to 24 weeks post-implantation via immunohistochemistry. Main results. Experimental results suggest that both probe and polymer coating sizes affect the extent of gliosis. When an appropriate sized coating dimension (100 µm  ×  100 µm) and small probe (30 µm  ×  5 µm) was implanted, a minimal post-implantation glial response was observed. No discernible gliosis was detected when compared to tissue where a sham control consisting of a solid degradable polymer shuttle of the same dimensions was inserted. A larger polymer coating (200 µm  ×  200 µm) device induced a more severe glial response at later time points, suggesting that the initial insertion trauma can affect gliosis even when the polymer shuttle degrades rapidly. A larger degree of gliosis was also observed when comparing a larger sized probe (80 µm  ×  5 µm) to a smaller probe (30 µm  ×  5 µm) using the same polymer coating size (100 µm  ×  100 µm). There was no significant neuronal loss around the implantation sites for most device candidates except the group with largest polymer coating and probe sizes. Significance. These results suggest that: (1) the degree of mechanical trauma at device implantation and mechanical mismatches at the probe-tissue interface affect long term gliosis; (2) smaller, more flexible probes may minimize the glial response to provide improved tissue biocompatibility when used for chronic neural signal recording; and (3) some degree of glial scarring did not significantly affect neuronal distribution around the probe.

  4. Evaluating the in vivo glial response to miniaturized parylene cortical probes coated with an ultra-fast degrading polymer to aid insertion.

    PubMed

    Lo, Meng-Chen; Wang, Shuwu; Singh, Sagar; Damodaran, Vinod B; Ahmed, Ijaz; Coffey, Kevin; Barker, David; Saste, Kshitij; Kals, Karanvir; Kaplan, Hilton M; Kohn, Joachim; Shreiber, David I; Zahn, Jeffrey D

    2018-06-01

    Despite the feasibility of short-term neural recordings using implantable microelectrodes, attaining reliable, chronic recordings remains a challenge. Most neural recording devices suffer from a long-term tissue response, including gliosis, at the device-tissue interface. It was hypothesized that smaller, more flexible intracortical probes would limit gliosis by providing a better mechanical match with surrounding tissue. This paper describes the in vivo evaluation of flexible parylene microprobes designed to improve the interface with the adjacent neural tissue to limit gliosis and thereby allow for improved recording longevity. The probes were coated with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)) polymer that provides temporary mechanical support for device implantation, yet degrades within 2 h post-implantation. A parametric study of probes of varying dimensions and polymer coating thicknesses were implanted in rat brains. The glial tissue response and neuronal loss were assessed from 72 h to 24 weeks post-implantation via immunohistochemistry. Experimental results suggest that both probe and polymer coating sizes affect the extent of gliosis. When an appropriate sized coating dimension (100 µm  ×  100 µm) and small probe (30 µm  ×  5 µm) was implanted, a minimal post-implantation glial response was observed. No discernible gliosis was detected when compared to tissue where a sham control consisting of a solid degradable polymer shuttle of the same dimensions was inserted. A larger polymer coating (200 µm  ×  200 µm) device induced a more severe glial response at later time points, suggesting that the initial insertion trauma can affect gliosis even when the polymer shuttle degrades rapidly. A larger degree of gliosis was also observed when comparing a larger sized probe (80 µm  ×  5 µm) to a smaller probe (30 µm  ×  5 µm) using the same polymer coating size (100 µm  ×  100 µm). There was no significant neuronal loss around the implantation sites for most device candidates except the group with largest polymer coating and probe sizes. These results suggest that: (1) the degree of mechanical trauma at device implantation and mechanical mismatches at the probe-tissue interface affect long term gliosis; (2) smaller, more flexible probes may minimize the glial response to provide improved tissue biocompatibility when used for chronic neural signal recording; and (3) some degree of glial scarring did not significantly affect neuronal distribution around the probe.

  5. Chronic Contained Rupture of an Abdominal Aortic Aneurysm: From Diagnosis to Endovascular Resolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gandini, Roberto, E-mail: marcello.chiocchi@fastwebnet.it; Chiocchi, Marcello; Maresca, Luciano

    2008-07-15

    A male patient, 69 years old, presented with fever, leucocytosis, and persistent low back pain; he also had an abdominal aortic aneurysm (AAA), as previously diagnosed by Doppler UltraSound (US), and was admitted to our hospital. On multislice computed tomography (msCT), a large abdominal mass having no definite border and involving the aorta and both of the psoas muscles was seen. This mass involved the forth-lumbar vertebra with lysis, thus simulating AAA rupture into a paraspinal collection; it was initially considered a paraspinal abscess. After magnetic resonance imaging examination and culture of the fluid aspirated from the mass, no infectivemore » organisms were found; therefore, a diagnosisof chronically contained AAA rupture was made, and an aortic endoprosthesis was subsequently implanted. The patient was discharged with decreased lumbar pain. At 12-month follow-up, no evidence of leakage was observed. To our knowledge, this is the first case of endoprosthesis implantation in a patient, who was a poor candidate for surgical intervention due to renal failure, leucocytosis and high fever, having a chronically contained AAA ruptured simulatingspodilodiscitis abscess. Appropriate diagnosis and therapy resolved potentially crippling pathology and avoided surgical graft-related complications.« less

  6. Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation

    PubMed Central

    2014-01-01

    Background Nerve cuff electrodes are commonly and successfully used for stimulating peripheral nerves. On the other hand, they occasionally induce functional and morphological changes following chronic implantation, for reasons not always clear. We hypothesize that restriction of nerve mobility due to cuff implantation may alter nerve conduction. Methods We quantified acute changes in nerve-muscle electrophysiology, using electromyography, and nerve kinematics in anesthetized Sprague Dawley rat sciatic nerves during controlled hindlimb joint movement. We compared electrophysiological and biomechanical response in uncuffed nerves and those secured within a cuff electrode using analysis of variance (ANOVA) and regression analysis. Results Tethering resulting from cuff implantation resulted in altered nerve strain and a complex biomechanical environment during joint movement. Coincident with biomechanical changes, electromyography revealed significantly increased variability in the response of conduction latency and amplitude in cuffed, but not free, nerves following joint movement. Conclusion Our findings emphasize the importance of the mechanical interface between peripheral nerves and their devices on neurophysiological performance. This work has implications for nerve device design, implantation, and prediction of long-term efficacy. PMID:24758405

  7. Cranioplasty after trephination using a novel biodegradable burr hole cover: technical case report.

    PubMed

    Schantz, Jan-Thorsten; Lim, Thiam-Chye; Ning, Chou; Teoh, Swee Hin; Tan, Kim Cheng; Wang, Shih Chang; Hutmacher, Dietmar Werner

    2006-02-01

    We have developed novel biodegradable polymer implants by using the rapid prototyping technology fused deposition modeling. Early results of a clinical pilot study for cranioplasty are presented. Five patients with the diagnosis of chronic subdural hematoma were included in the study. After trephination and evacuation of the subdural hematoma, burr holes (diameter, 14 mm) were closed using a biodegradable implant made of polycaprolactone. Implants were computer designed with an upper rim diameter of 16 mm and a 14 mm body diameter with a fully interconnected, honeycomb-like architecture of 400 to 600 microm in pore size. Postoperative computed tomographic scans indicated that the plugs were stably anchored in the osseous host environment with no fluid collection detectable. The postoperative course was uneventful, and patients were discharged after 5 days. Follow-up scans after 3, 6, and 12 months showed that the implants were well integrated in the surrounding calvarial bone with new bone filling the porous space. These novel polymer scaffolds made of the slow-degrading material polycaprolactone represent a suitable implant for closure of post-trephination defects.

  8. Mechanisms of alpha 1-adrenergic vascular desensitization in conscious dogs

    NASA Technical Reports Server (NTRS)

    Kiuchi, K.; Vatner, D. E.; Uemura, N.; Bigaud, M.; Hasebe, N.; Hempel, D. M.; Graham, R. M.; Vatner, S. F.

    1992-01-01

    To investigate the mechanisms of alpha 1-adrenergic vascular desensitization, osmotic minipumps containing either saline (n = 9) or amidephrine mesylate (AMD) (n = 9), a selective alpha 1-adrenergic receptor agonist, were implanted subcutaneously in dogs with chronically implanted arterial and right atrial pressure catheters and aortic flow probes. After chronic alpha 1-adrenergic receptor stimulation, significant physiological desensitization to acute AMD challenges was observed, i.e., pressor and vasoconstrictor responses to the alpha 1-adrenergic agonist were significantly depressed (p < 0.01) compared with responses in the same dogs studied in the conscious state before pump implantation. However, physiological desensitization to acute challenges of the neurotransmitter norepinephrine (NE) (0.1 micrograms/kg per minute) in the presence of beta-adrenergic receptor blockade was not observed for either mean arterial pressure (MAP) (30 +/- 7 versus 28 +/- 5 mm Hg) or total peripheral resistance (TPR) (29.8 +/- 4.9 versus 28.9 +/- 7.3 mm Hg/l per minute). In the presence of beta-adrenergic receptor plus ganglionic blockade after AMD pump implantation, physiological desensitization to NE was unmasked since the control responses to NE (0.1 micrograms/kg per minute) before the AMD pumps were now greater (p < 0.01) than after chronic AMD administration for both MAP (66 +/- 5 versus 32 +/- 2 mm Hg) and TPR (42.6 +/- 10.3 versus 23.9 +/- 4.4 mm Hg/l per minute). In the presence of beta-adrenergic receptor, ganglionic, plus NE-uptake blockade after AMD pump implantation, desensitization was even more apparent, since NE (0.1 micrograms/kg per minute) induced even greater differences in MAP (33 +/- 5 versus 109 +/- 6 mm Hg) and TPR (28.1 +/- 1.8 versus 111.8 +/- 14.7 mm Hg/l per minute). The maximal force of contraction induced by NE in the presence or absence of endothelium was significantly decreased (p < 0.05) in vitro in mesenteric artery rings from AMD pump dogs compared with saline control dogs. Furthermore, alpha 1-adrenergic receptor density, as determined by [3H]prazosin binding in membrane preparations from vessels in the mesentery, was decreased (8.2 +/- 1.0 versus 18.4 +/- 1.4 fmol/mg protein, p < 0.001) without any change in Kd in the AMD pump dogs compared with the saline pump dogs.(ABSTRACT TRUNCATED AT 400 WORDS).

  9. 3D printing and modelling of customized implants and surgical guides for non-human primates.

    PubMed

    Chen, Xing; Possel, Jessy K; Wacongne, Catherine; van Ham, Anne F; Klink, P Christiaan; Roelfsema, Pieter R

    2017-07-15

    Primate neurobiologists use chronically implanted devices such as pedestals for head stabilization and chambers to gain access to the brain and study its activity. Such implants are skull-mounted, and made from a hard, durable material, such as titanium. Here, we present a low-cost method of creating customized 3D-printed cranial implants that are tailored to the anatomy of individual animals. We performed pre-surgical computed tomography (CT) and magnetic resonance (MR) scans to generate three-dimensional (3D) models of the skull and brain. We then used 3D modelling software to design implantable head posts, chambers, and a pedestal anchorage base, as well as craniotomy guides to aid us during surgery. Prototypes were made from plastic or resin, while implants were 3D-printed in titanium. The implants underwent post-processing and received a coating of osteocompatible material to promote bone integration. Their tailored fit greatly facilitated surgical implantation, and eliminated the gap between the implant and the bone. To date, our implants remain robust and well-integrated with the skull. Commercial-off-the-shelf solutions typically come with a uniform, flat base, preventing them from sitting flush against the curved surface of the skull. This leaves gaps for fluid and tissue ingress, increasing the risk of microbial infection and tissue inflammation, as well as implant loss. The use of 3D printing technology enabled us to quickly and affordably create unique, complex designs, avoiding the constraints levied by traditional production methods, thereby boosting experimental success and improving the wellbeing of the animals. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  10. Benefits of active middle ear implants in mixed hearing loss: Stapes versus round window.

    PubMed

    Lee, Jeon Mi; Jung, Jinsei; Moon, In Seok; Kim, Sung Huhn; Choi, Jae Young

    2017-06-01

    We compared the audiologic benefits of active middle ear implants with those of passive middle ear implants with hearing aids in mixed hearing loss, and also compared the outcomes of stapes vibroplasty with those of round window vibroplasty. Retrospective chart review. Thirty-four patients with mixed hearing loss due to chronic otitis media were treated with a middle ear implant. Of these, 15 were treated with a passive middle ear implant (conventional ossiculoplasty with a partial ossicular replacement prosthesis), nine with an active middle ear implant coupling to the stapes, and 10 with an active middle ear implant coupling to the round window. Patients underwent pure-tone/free-field audiograms and speech discrimination tests before surgery and 6 months after surgery, and the results of these tests were compared. The active middle ear implant resulted in better outcomes than the passive middle ear implant with hearing aids at mid to high frequencies (P < .05). Patients who received either a stapes vibroplasty or a round window vibroplasty showed comparable hearing gain except at 8,000 Hz (48.9 dB vs. 31.0 dB, P < .05). Patients who received a stapes vibroplasty showed an improvement even in bone conduction at 1,000 Hz and 2,000 Hz (both P < .05). Active middle ear implantation could be a better option than treatment with passive middle ear implants with hearing aids for achieving rehabilitation in patients with mixed hearing loss. Vibroplasty via either oval window or round window stimulation shares similar good results. 4 Laryngoscope, 127:1435-1441, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  11. A review of implantable biosensors for closed-loop glucose control and other drug delivery applications.

    PubMed

    Scholten, Kee; Meng, Ellis

    2018-06-15

    Closed-loop drug delivery promises autonomous control of pharmacotherapy through the continuous monitoring of biomarker levels. For decades, researchers have strived for portable closed-loop systems capable of treating ambulatory patients with chronic conditions such as diabetes mellitus. After years of development, the first of these systems have left the laboratory and entered commercial use. This long-awaited advance reflects recent development of chronically stable implantable biosensors able to accurately measure biomarker levels in vivo. This review discusses the role of implantable biosensors in closed-loop drug delivery applications, with the intent to provide a resource for engineers and researchers studying such systems. We provide an overview of common biosensor designs and review the principle challenges in implementing long indwelling sensors: namely device sensitivity, selectivity, and lifetime. This review examines novel advances in transducer design, biological interface, and material biocompatibility, with a focus on recent academic and commercial work which provide successful strategies to overcome perennial challenges. This review focuses primarily on the topics of closed-loop glucose control and continuous glucose monitoring biosensors, which make up the overwhelming majority of published research in this area. We conclude with an overview of recent advances in closed-loop systems targeting applications outside blood glucose management. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. The biological response to orthopedic implants for joint replacement. II: Polyethylene, ceramics, PMMA, and the foreign body reaction.

    PubMed

    Gibon, Emmanuel; Córdova, Luis A; Lu, Laura; Lin, Tzu-Hua; Yao, Zhenyu; Hamadouche, Moussa; Goodman, Stuart B

    2017-08-01

    Novel evidence-based prosthetic designs and biomaterials facilitate the performance of highly successful joint replacement (JR) procedures. To achieve this goal, constructs must be durable, biomechanically sound, and avoid adverse local tissue reactions. Different biomaterials such as metals and their alloys, polymers, ceramics, and composites are currently used for JR implants. This review focuses on (1) the biological response to the different biomaterials used for TJR and (2) the chronic inflammatory and foreign-body response induced by byproducts of these biomaterials. A homeostatic state of bone and surrounding soft tissue with current biomaterials for JR can be achieved with mechanically stable, infection free and intact (as opposed to the release of particulate or ionic byproducts) implants. Adverse local tissue reactions (an acute/chronic inflammatory reaction, periprosthetic osteolysis, loosening and subsequent mechanical failure) may evolve when the latter conditions are not met. This article (Part 2 of 2) summarizes the biological response to the non-metallic materials commonly used for joint replacement including polyethylene, ceramics, and polymethylmethacrylate (PMMA), as well as the foreign body reaction to byproducts of these materials. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1685-1691, 2017. © 2016 Wiley Periodicals, Inc.

  13. Occipital peripheral nerve stimulation in the management of chronic intractable occipital neuralgia in a patient with neurofibromatosis type 1: a case report

    PubMed Central

    2011-01-01

    Introduction Occipital peripheral nerve stimulation is an interventional pain management therapy that provides beneficial results in the treatment of refractory chronic occipital neuralgia. Herein we present a first-of-its-kind case study of a patient with neurofibromatosis type 1 and bilateral occipital neuralgia treated with occipital peripheral nerve stimulation. Case presentation A 42-year-old Caucasian woman presented with bilateral occipital neuralgia refractory to various conventional treatments, and she was referred for possible treatment with occipital peripheral nerve stimulation. She was found to be a suitable candidate for the procedure, and she underwent implantation of two octapolar stimulating leads and a rechargeable, programmable, implantable generator. The intensity, severity, and frequency of her symptoms resolved by more than 80%, but an infection developed at the implantation site two months after the procedure that required explantation and reimplantation of new stimulating leads three months later. To date she continues to experience symptom resolution of more than 60%. Conclusion These results demonstrate the significance of peripheral nerve stimulation in the management of refractory occipital neuralgias in patients with neurofibromatosis type 1 and the possible role of neurofibromata in the development of occipital neuralgia in these patients. PMID:21569290

  14. Functionalization-Free Microfluidic Electronic Tongue Based on a Single Response.

    PubMed

    Shimizu, Flavio M; Todão, Fagner R; Gobbi, Angelo L; Oliveira, Osvaldo N; Garcia, Carlos D; Lima, Renato S

    2017-07-28

    Electronic tongues (e-tongues) are promising analytical devices for a variety of applications to address the challenges of quality control in water monitoring and industries of foods, beverages, and pharmaceuticals. A crucial drawback in the current e-tongues is the need to recalibrate the device when one or more sensing units (usually with modified surface) are replaced. Another downside is the necessity to perform subsequent surface modifications and analyses to each of the diverse sensing units, undermining the simplicity and velocity of the method. These features have prevented widespread commercial use of the e-tongues. In this paper, we introduce a microfluidic e-tongue that overcomes all such limitations. The key principle of global selectivity of the e-tongue was achieved by recording only a single response, namely, the equivalent admittance spectrum of an association of resistors in parallel. Such resistors consisted of five nonfunctionalized stainless steel microwires (sensing units), which were short-circuited and coated with gold, platinum, nickel, iron, and aluminum oxide films. The microwires were inserted in a chip composed of a single piece of polydimethylsiloxane (PDMS). Using impedance spectroscopy, the e-tongue was successfully applied in classification of basic tastes at a concentration below the threshold for the human tongue. In addition, our chip allowed the distinction of various chemicals used in oil industry. Finally, our cleanroom-free prototyping allows the mass production of chips with easily replaceable and reproducible sensing units. Hence, one can now envisage the widespread dissemination of e-tongues with fast and reproducible data.

  15. Antinociceptive effect of intrathecal microencapsulated human pheochromocytoma cell in a rat model of bone cancer pain.

    PubMed

    Li, Xiao; Li, Guoqi; Wu, Shaoling; Zhang, Baiyu; Wan, Qing; Yu, Ding; Zhou, Ruijun; Ma, Chao

    2014-07-08

    Human pheochromocytoma cells, which are demonstrated to contain and release met-enkephalin and norepinephrine, may be a promising resource for cell therapy in cancer-induced intractable pain. Intrathecal injection of alginate-poly (l) lysine-alginate (APA) microencapsulated human pheochromocytoma cells leads to antinociceptive effect in a rat model of bone cancer pain, and this effect was blocked by opioid antagonist naloxone and alpha 2-adrenergic antagonist rauwolscine. Neurochemical changes of cerebrospinal fluid are in accordance with the analgesic responses. Taken together, these data support that human pheochromocytoma cell implant-induced antinociception was mediated by met-enkephalin and norepinephrine secreted from the cell implants and acting at spinal receptors. Spinal implantation of microencapsulated human pheochromocytoma cells may provide an alternative approach for the therapy of chronic intractable pain.

  16. Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

    PubMed

    Galassi, Alfredo R; Tomasello, Salvatore D; Costanzo, Luca; Campisano, Maria B; Barrano, Giombattista; Tamburino, Corrado

    2011-10-01

    Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization. ©2011, Wiley Periodicals, Inc.

  17. Peripheral nerve field stimulation (PNFS) in chronic low back pain: a prospective multicenter study.

    PubMed

    Kloimstein, Herwig; Likar, Rudolf; Kern, Michael; Neuhold, Josef; Cada, Miroslav; Loinig, Nadja; Ilias, Wilfried; Freundl, Brigitta; Binder, Heinrich; Wolf, Andreas; Dorn, Christian; Mozes-Balla, Eva Maria; Stein, Rolf; Lappe, Ivo; Sator-Katzenschlager, Sabine

    2014-02-01

    The goal of this study was to evaluate the long-term efficacy and safety of peripheral nerve field stimulation (PNFS) for chronic low back pain (cLBP). In this prospective, multicenter observational study, 118 patients were admitted to 11 centers throughout Austria and Switzerland. After a screening visit, all patients underwent a trial stimulation period of at least seven days before implantation of the permanent system. Leads were placed in the subcutaneous tissues of the lower back directly in the region of greatest pain. One hundred five patients were implanted with a permanent stimulating system. Patients' evaluation of pain and functional levels were completed before implantation and one, three, and six months after implantation. Adverse events, medication usage, and coverage of the painful area and predictive value of transcutaneous electrical nerve stimulation (TENS) were monitored. All pain and quality-of-life measures showed statistically significant improvement during the treatment period. These included the average pain visual analog scale, the Oswestry Disability Questionnaire, the Becks Depression Inventory, and the Short Form-12 item Health survey. Additionally, medication usage with opioids, nonsteroidal anti-inflammatory drugs, and anti-convulsants showed a highly significant reduction. Complications requiring surgical intervention were reported in 9.6% of the patients. The degree of coverage of painful areas seems to be an important criterion for efficacy of PNFS, whereas TENS is presumably no predictor. This prospective, multicenter study confirms that PNFS is an effective therapy for the management of cLBP. Significant improvements in many aspects of the pain condition were measured, and complications were minimal. © 2013 International Neuromodulation Society.

  18. Bio-inspired hybrid microelectrodes: a hybrid solution to improve long-term performance of chronic intracortical implants.

    PubMed

    De Faveri, Sara; Maggiolini, Emma; Miele, Ermanno; De Angelis, Francesco; Cesca, Fabrizia; Benfenati, Fabio; Fadiga, Luciano

    2014-01-01

    The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes - over time - compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses.

  19. Chronic Exposure to Bisphenol A Affects Uterine Function During Early Pregnancy in Mice

    PubMed Central

    Davila, Juanmahel; Kannan, Athilakshmi; Flaws, Jodi A.; Bagchi, Milan K.

    2016-01-01

    Environmental and occupational exposure to bisphenol A (BPA), a chemical widely used in polycarbonate plastics and epoxy resins, has received much attention in female reproductive health due to its widespread toxic effects. Although BPA has been linked to infertility and recurrent miscarriage in women, the impact of its exposure on uterine function during early pregnancy remains unclear. In this study, we addressed the effect of prolonged exposure to an environmental relevant dose of BPA on embryo implantation and establishment of pregnancy. Our studies revealed that treatment of mice with BPA led to improper endometrial epithelial and stromal functions thus affecting embryo implantation and establishment of pregnancy. Upon further analyses, we found that the expression of progesterone receptor (PGR) and its downstream target gene, HAND2 (heart and neural crest derivatives expressed 2), was markedly suppressed in BPA-exposed uterine tissues. Previous studies have shown that HAND2 controls embryo implantation by repressing fibroblast growth factor and the MAPK signaling pathways and inhibiting epithelial proliferation. Interestingly, we observed that down-regulation of PGR and HAND2 expression in uterine stroma upon BPA exposure was associated with enhanced activation of fibroblast growth factor and MAPK signaling in the epithelium, thus contributing to aberrant proliferation and lack of uterine receptivity. Further, the differentiation of endometrial stromal cells to decidual cells, an event critical for the establishment and maintenance of pregnancy, was severely compromised in response to BPA. In summary, our studies revealed that chronic exposure to BPA impairs PGR-HAND2 pathway and adversely affects implantation and the establishment of pregnancy. PMID:27022677

  20. Cardiovascular implantable electronic device infections in left ventricular assist device recipients.

    PubMed

    Riaz, Talha; Nienaber, Juhsien J C; Baddour, Larry M; Walker, Randall C; Park, Soon J; Sohail, Muhammad Rizwan

    2014-02-01

    Most patients with left ventricular assist devices (LVADs) have concomitant cardiovascular implantable electronic devices (CIEDs). However, clinical presentation and outcome of CIED infection in the setting of LVAD has not been previously described. We retrospectively reviewed 247 patients who underwent LVAD implantation at Mayo Clinic campuses in Minnesota, Arizona, and Florida, from January 2005 to December 2011. Demographic and clinical data of patients who met criteria for CIED infection were extracted. Of 247 patients with LVADs, 215 (87%) had CIED at the time of LVAD implantation and six (2.8%) subsequently developed CIED infections. Three patients developed CIED lead-related endocarditis and the other three had pocket infection. All three instances of CIED pocket infection were preceded by device generator exchange, whereas all three patients with CIED lead-related endocarditis had prior LVAD-related infections. Causative pathogens included Pseudomonas aeruginos (1), coagulase-negative staphylococci (2), methicillin-resistant Staphylococcus aureus (1), a gram-positive bacillus (1), and culture negative (2). All patients underwent complete CIED removal along with antimicrobial therapy. The three patients with CIED lead-related endocarditis and prior LVAD infections received chronic suppressive antibiotic therapy, and one patient had LVAD exchange. All but one remained alive at the last follow-up with a median duration of 15 months (7-46 months) from the time of CIED infection. Patients who are receiving LVAD therapy and develop CIED infection should be managed with complete CIED removal. Chronic suppressive antibiotic therapy is warranted in cases that have concomitant LVAD infection. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  1. Left ventricular assist device management in patients chronically supported for advanced heart failure.

    PubMed

    Cowger, Jennifer; Romano, Matthew A; Stulak, John; Pagani, Francis D; Aaronson, Keith D

    2011-03-01

    This review summarizes management strategies to reduce morbidity and mortality in heart failure patients supported chronically with implantable left ventricular assist devices (LVADs). As the population of patients supported with long-term LVADs has grown, patient selection, operative technique, and patient management strategies have been refined, leading to improved outcomes. This review summarizes recent findings on LVAD candidate selection, and discusses outpatient strategies to optimize device performance and heart failure management. It also reviews important device complications that warrant close outpatient monitoring. Managing patients on chronic LVAD support requires regular patient follow-up, multidisciplinary care teams, and frequent laboratory and echocardiographic surveillance to ensure optimal outcomes.

  2. Corticosteroid implants for chronic non-infectious uveitis

    PubMed Central

    Brady, Christopher J; Villanti, Andrea C; Law, Hua Andrew; Rahimy, Ehsan; Reddy, Rahul; Sieving, Pamela C; Garg, Sunir J; Tang, Johnny

    2016-01-01

    Background Uveitis is a term used to describe a heterogeneous group of intraocular inflammatory diseases of the anterior, intermediate, and posterior uveal tract (iris, ciliary body, choroid). Uveitis is the fifth most common cause of vision loss in high-income countries, accounting for 5% to 20% of legal blindness, with the highest incidence of disease in the working-age population. Corticosteroids are the mainstay of acute treatment for all anatomical subtypes of non-infectious uveitis and can be administered orally, topically with drops or ointments, by periocular (around the eye) or intravitreal (inside the eye) injection, or by surgical implantation. Objectives To determine the efficacy and safety of steroid implants in people with chronic non-infectious posterior uveitis, intermediate uveitis, and panuveitis. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (Issue 10, 2015), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to November 2015), EMBASE (January 1980 to November 2015), PubMed (1948 to November 2015), Latin American and Caribbean Health Sciences Literature Database (LILACS) (1982 to November 2015), the metaRegister of Controlled Trials (mRCT) (www.controlledtrials.com) (last searched 15 April 2013), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform(ICTRP) (www.who.int/ictrp/search/en).We did not use any date or language restrictions in the electronic search for studies. We last searched the electronic databases on 6 November 2015. We also searched reference lists of included study reports, citation databases, and abstracts and clinical study presentations from professional meetings. Selection criteria We included randomized controlled trials comparing either fluocinolone acetonide (FA) or dexamethasone intravitreal implants with standard-of-care therapy with at least six months of follow-up after treatment. We included studies that enrolled participants of all ages who had chronic non-infectious posterior uveitis, intermediate uveitis, or panuveitis with vision that was better than hand-motion. Data collection and analysis Two review authors independently reviewed studies for inclusion. Two review authors independently extracted data and assessed the risk of bias for each study. Main results We included data from two studies (619 eyes of 401 participants) that compared FA implants with standard-of-care therapy. Both studies used similar standard-of-care therapy that included administration of prednisolone and, if needed, immunosuppressive agents. The studies included participants from Australia, France, Germany, Israel, Italy, Portugal, Saudi Arabia, Spain, Switzerland, Turkey, the United Kingdom, and the United States. We assessed both studies at high risk of performance and detection bias. Only one study reported our primary outcome, recurrence of uveitis at any point during the study through 24 months. The evidence, judged as moderate-quality, showed that a FA implant probably prevents recurrence of uveitis compared with standard-of-care therapy (risk ratio (RR) 0.29, 95% confidence interval (CI) 0.14 to 0.59; 132 eyes). Both studies reported safety outcomes, and moderate-quality evidence showed increased risks of needing cataract surgery (RR 2.98, 95% CI 2.33 to 3.79; 371 eyes) and surgery to lower intraocular pressure (RR 7.48, 95% CI 3.94 to 14.19; 599 eyes) in the implant group compared with standard-of-care therapy through two years of follow-up. No studies compared dexamethasone implants with standard-of-care therapy. Authors’ conclusions After considering both benefits and harms reported from two studies in which corticosteroids implants were compared with standard-of-care therapy, we are unable to conclude that the implants are superior to traditional systemic therapy for the treatment of noninfectious uveitis. These studies exhibited heterogeneity in design and outcomes that measured efficacy. Pooled findings regarding safety outcomes suggest increased risks of post-implant surgery for cataract and high intraocular pressure compared with standard-of-care therapy. PMID:26866343

  3. Microelectronic bioinstrumentation systems

    NASA Technical Reports Server (NTRS)

    Ko, W. H.

    1976-01-01

    Progress was made in the development of an RF cage, a single channel RF powered ECG telemetry system, and a three channel RF powered ECG, aortic blood pressure, and body temperature telemetry system. Encapsulation materials for chronic implantation of electronic circuits in the body were also evaluated.

  4. Ex vivo bone morphogenetic protein 2 gene delivery using periodontal ligament stem cells for enhanced re-osseointegration in the regenerative treatment of peri-implantitis.

    PubMed

    Park, Shin-Young; Kim, Kyoung-Hwa; Gwak, Eun-Hye; Rhee, Sang-Hoon; Lee, Jeong-Cheol; Shin, Seung-Yun; Koo, Ki-Tae; Lee, Yong-Moo; Seol, Yang-Jo

    2015-01-01

    Peri-implantitis is a chronic inflammatory process with advanced bone loss and impaired healing potential. For peri-implantitis treatment, tissue engineering can be applied to enhance bone regeneration of peri-implant defects. This study aimed to evaluate ex vivo bone morphogenetic protein 2 (BMP2) gene delivery using canine periodontal ligament stem cells (PDLSCs) for regeneration of peri-implantitis defects. Canine PDLSCs were transduced with adenoviral vectors containing BMP2 (BMP2/PDLSCs). After peri-implantitis was induced by ligature placement in six beagle dogs, regenerative procedures were performed; hydroxyapatite (HA) particles and collagen gel with autologous canine PDLSCs (PDLSC group) or BMP2/PDLSCs (BMP/PDLSC group) or without cells (control group) were grafted into the defects and covered by an absorbable membrane. Three months later, the animals were sacrificed. In vitro, BMP2/PDLSCs showed similar levels of stem cell properties to PDLSCs, such as colony-forming efficiency and expression of MSC markers STRO-1 and CD 146. BMP2/PDLSCs produced BMP-2 until day 21 at a concentration of 4-8 ng/mL. In vivo, the BMP2/PDLSC group showed significantly more new bone formation and re-osseointegration in peri-implantitis defects compared to the other groups. In conclusion, ex vivo BMP2 gene delivery using PDLSCs enhanced new bone formation and re-osseointegration in peri-implantitis defects. © 2014 Wiley Periodicals, Inc.

  5. Fibrin(ogen) mediates acute inflammatory responses to biomaterials

    PubMed Central

    1993-01-01

    Although "biocompatible" polymeric elastomers are generally nontoxic, nonimmunogenic, and chemically inert, implants made of these materials may trigger acute and chronic inflammatory responses. Early interactions between implants and inflammatory cells are probably mediated by a layer of host proteins on the material surface. To evaluate the importance of this protein layer, we studied acute inflammatory responses of mice to samples of polyester terephthalate film (PET) that were implanted intraperitoneally for short periods. Material preincubated with albumin is "passivated," accumulating very few adherent neutrophils or macrophages, whereas uncoated or plasma- coated PET attracts large numbers of phagocytes. Neither IgG adsorption nor surface complement activation is necessary for this acute inflammation; phagocyte accumulation on uncoated implants is normal in hypogammaglobulinemic mice and in severely hypocomplementemic mice. Rather, spontaneous adsorption of fibrinogen appears to be critical: (a) PET coated with serum or hypofibrinogenemic plasma attracts as few phagocytes as does albumin-coated material; (b) in contrast, PET preincubated with serum or hypofibrinogenemic plasma containing physiologic amounts of fibrinogen elicits "normal" phagocyte recruitment; (c) most importantly, hypofibrinogenemic mice do not mount an inflammatory response to implanted PET unless the material is coated with fibrinogen or the animals are injected with fibrinogen before implantation. Thus, spontaneous adsorption of fibrinogen appears to initiate the acute inflammatory response to an implanted polymer, suggesting an interesting nexus between two major iatrogenic effects of biomaterials: clotting and inflammation. PMID:8245787

  6. The role of autologous chondrocyte implantation in the treatment of symptomatic chondromalacia patellae.

    PubMed

    Macmull, Simon; Jaiswal, Parag K; Bentley, George; Skinner, John A; Carrington, Richard W J; Briggs, Tim W R

    2012-07-01

    Chondromalacia patella is a distinct clinical entity of abnormal softening of the articular cartilage of the patella, which results in chronic retropatellar pain. Its aetiology is still unclear but the process is thought to be a due to trauma to superficial chondrocytes resulting in a proteolytic enzymic breakdown of the matrix. Our aim was to assess the effectiveness of autologous chondrocyte implantation on patients with a proven symptomatic retropatellar lesion who had at least one failed conventional marrow-stimulating therapy. We performed chondrocyte implantation on 48 patients: 25 received autologous chondrocyte implantation with a type I/III membrane (ACI-C) method (Geistlich Biomaterials, Wolhusen, Switzerland), and 23 received the Matrix-assisted Chondrocyte Implantation (MACI) technique (Genzyme, Kastrup, Denmark). Over a mean follow-up period of 40.3 months, there was a statistically significant improvement in subjective pain scoring using the visual analogue scale (VAS) and objective functional scores using the Modified Cincinnati Rating System (MCS) in both groups. Chondromalacia patellae lesions responded well to chondrocyte implantation. Better results occurred with MACI than with ACI-C. Excellent and good results were achieved in 40% of ACI-C patients and 57% of MACI patients, but success of chondrocyte implantation was greater with medial/odd-facet lesions. Given that the MACI procedure is technically easier and less time consuming, we consider it to be useful for treating patients with symptomatic chondral defects secondary to chondromalacia patellae.

  7. Long-term outcomes of phakic patients with diabetic macular oedema treated with intravitreal fluocinolone acetonide (FAc) implants.

    PubMed

    Yang, Y; Bailey, C; Holz, F G; Eter, N; Weber, M; Baker, C; Kiss, S; Menchini, U; Ruiz Moreno, J M; Dugel, P; Lotery, A

    2015-09-01

    Diabetic macular oedema (DMO) is a leading cause of blindness in working-age adults. Slow-release, nonbioerodible fluocinolone acetonide (FAc) implants have shown efficacy in the treatment of DMO; however, the National Institute for Health and Care Excellence recommends that FAc should be used in patients with chronic DMO considered insufficiently responsive to other available therapies only if the eye to be treated is pseudophakic. The goal of this analysis was to examine treatment outcomes in phakic patients who received 0.2 μg/day FAc implant. This analysis of the phase 3 FAME (Fluocinolone Acetonide in Diabetic Macular Edema) data examines the safety and efficacy of FAc implants in patients who underwent cataract extraction before (cataract before implant (CBI) group) or after (cataract after implant (CAI) group) receiving the implant. The data were further examined by DMO duration. Best corrected visual acuity (BCVA) after 36 months was comparable in the CAI and CBI groups. Both the percentage of patients gaining ≥ 3 lines of vision and mean change in BCVA letter score were numerically greater in the CAI group. In addition, most patients who underwent cataract surgery experienced a net gain in BCVA from presurgery baseline as well as from original study baseline. These data support the use of 0.2 μg/day FAc implants in phakic as well as in pseudophakic patients. These findings will serve as a pilot for design of future studies to evaluate the potential protective effect of FAc implants before cataract surgery in patients with DMO and cataract.

  8. Evaluation of laser bacterial anti-fouling of transparent nanocrystalline yttria-stabilized-zirconia cranial implant.

    PubMed

    Damestani, Yasaman; De Howitt, Natalie; Halaney, David L; Garay, Javier E; Aguilar, Guillermo

    2016-10-01

    The development and feasibility of a novel nanocrystalline yttria-stabilized-zirconia (nc-YSZ) cranial implant has been recently established. The purpose of what we now call "window to the brain (WttB)" implant (or platform), is to improve patient care by providing a technique for delivery and/or collection of light into/from the brain, on demand, over large areas, and on a chronically recurring basis without the need for repeated craniotomies. WttB holds the transformative potential for enhancing light-based diagnosis and treatment of a wide variety of brain pathologies including cerebral edema, traumatic brain injury, stroke, glioma, and neurodegenerative diseases. However, bacterial adhesion to the cranial implant is the leading factor for biofilm formation (fouling), infection, and treatment failure. Escherichia coli (E. coli), in particular, is the most common isolate in gram-negative bacillary meningitis after cranial surgery or trauma. The transparency of our WttB implant may provide a unique opportunity for non-invasive treatment of bacterial infection under the implant using medical lasers. A drop of a diluted overnight culture of BL21-293 E. coli expressing luciferase was seeded between the nc-YSZ implant and the agar plate. This was followed by immediate irradiation with selected laser. After each laser treatment the nc-YSZ was removed, and cultures were incubated for 24 hours at 37 °C. The study examined continuous wave (CW) and pulsed wave (PW) modes of near-infrared (NIR) 810 nm laser wavelength with a power output ranging from 1 to 3 W. During irradiation, the temperature distribution of nc-YSZ surface was monitored using an infrared thermal camera. Relative luminescence unit (RLU) was used to evaluate the viability of bacteria after the NIR laser treatment. Analysis of RLU suggests that the viability of E. coli biofilm formation was reduced with NIR laser treatment when compared to the control group (P < 0.01) and loss of viability depends on both laser fluence and operation mode (CW or PW). The results demonstrate that while CW laser reduces the biofilm formation more than PW laser with the same power, the higher surface temperature of the implant generated by CW laser limits its medical efficacy. In contrast, with the right parameters, PW laser produces a more moderate photothermal effect which can be equally effective at controlling bacterial growth. Our results show that E. coli biofilm formation across the thickness of the nc-YSZ implant can be disrupted using NIR laser treatment. The results of this in vitro study suggest that using nc-YSZ as a cranial implant in vivo may also allow for locally selective, non-invasive, chronic treatment of bacterial layers (fouling) that might form under cranial implants, without causing adverse thermal damage to the underlying host tissue when appropriate laser parameters are used. Lasers Surg. Med. 48:782-789, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. First Report of 90-Day Support of Two Calves with a Continuous-Flow Total Artificial Heart

    PubMed Central

    Karimov, Jamshid H.; Moazami, Nader; Kobayashi, Mariko; Sale, Shiva; Such, Kimberly; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Gao, Shengqiang; Kuban, Barry; Golding, Leonard A.; Fukamachi, Kiyotaka

    2015-01-01

    Objective The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. Methods CFTAH pumps have been implanted in 17 calves total. Hemodynamics, pump performance, and device-related adverse events were evaluated during studies and at necropsy. Results In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure [LAP], 16 ± 3 mm Hg; right atrial pressure [RAP], 17 ± 3 mm Hg; RAP-LAP difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three recent animals with the CFTAH recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last two were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. Conclusions The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy. PMID:26173607

  10. The Results of Neuroendoscopic Surgery in Patients with Posttraumatic and Posthemorrhagic Hydrocephalus.

    PubMed

    Chrastina, Jan; Novák, Zdeněk; Zeman, Tomáš; Feitová, Věra; Hrabovský, Dušan; Říha, Ivo

    2018-05-01

    Posttraumatic hydrocephalus (PTH) and posthemorrhagic hydrocephalus (PHH) were previously considered not suitable for neuroendoscopic treatment. New hydrocephalus theories support possible successful neuroendoscopy in such patients. This study presents the results of neuroendoscopy in PTH and PHH with a background analysis. From 130 hydrocephalic patients after neuroendoscopic surgeries, 35 cases with PTH (n = 11) or PHH (n = 24; acute: n = 9, subacute: n = 10, chronic: n = 5) were found. The success rate (Glasgow Outcome Scale [GOS] score 4 or 5 without shunt) and clinical outcome (GOS score) of endoscopic third ventriculostomy (ETV) were analyzed. During the study period, 34 patients had ventriculoperitoneal shunts implanted, including 2 PTH and 5 PHH patients (all chronic). The success rate of ETV in PTH was 54.5%. In acute PHH, the success rate was 33.3%, 42.8% after excluding devastating hematomas. A post-ETV shunt was implanted in 1 patient (massive subarachnoid hemorrhage [SAH]) with final GOS score of 5. In subacute cases, the ETV success rate was 40% (no post-ETV shunts). In chronic PHH, only 1 patient with a GOS score of 5 was shunt-free (20%). The cause of ETV failure was massive SAH. Low final GOS score was caused by the extent of intracerebral bleeding or extracranial problems. The main indications for primary shunt implantation in PTH and PHH were infectious complications. The rate of good outcomes was 0% in PTH and 40% in PHH. The best results of neuroendoscopy were achieved in PTH and acute PHH. ETV failures were associated with massive SAH; arachnoid cistern blockage and scarring precludes ETV success. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Combination of Ultrasonic Decontamination, Soft Tissue Curettage and Submucosal Air Polishing With Povidone-Iodine Application for Non-Surgical Therapy of Peri-Implantitis: 12 Months Clinical Outcomes.

    PubMed

    Stein, Jamal M; Hammächer, Christian; Said-Yekta Michael, Sareh

    2017-09-15

    The aim of this study was to evaluate the clinical outcomes of a concept for non-surgical peri-implantitis combining stepwise mechanical debridement measures with adjuvant Povidone-iodine application with and without systemic antibiotics. 45 patients with chronic periodontitis comprising 164 screw-typed implants with peri-implantitis were included. Peri-implantitis was defined as radiographic bone loss of >2 mm, probing pocket depth (PD) ≥5 mm with bleeding on probing (BOP). Stepwise treatment of implants was performed with ultrasonic debridement, soft tissue curettage (STC), glycine powder air polishing (GPAP) and a repeated submucosal application of Povidone-iodine. Teeth with PD >4mm were treated simultaneously according to the same concept except STC. In cases with severe periodontitis (N = 24), amoxicillin and metronidazole (AM) were prescribed for 7 days. After 12 months, implants treated without AM showed significant reductions (p<0.05) of mean PD (1.4 ± 0.7 mm), CAL (1.3 ± 0.8 mm) and BOP (33.4 ± 17.2%). In deep pockets (PD >6mm) changes of mean PD (2.3 ± 1.3 mm), CAL (2.0 ± 1.6 mm) and BOP (44.0 ± 41.7%) were more pronounced. Intake of AM did not significantly influence the changes of these parameters. However, the reduction of implant sites with PD >4 mm and BOP was significantly higher in patients with AM than in those without AM (31.8 ± 12.6% vs. 20.8 ± 14.7%; p<0.05). The combination of ultrasonic debridement, STC and GPAP with adjuvant Povidone-iodine led to significant clinical improvements at implants. Systemic antibiotics had limited effects on the reduction of persisting implant sites with treatment need.

  12. An easy access to retrieve dental implants displaced into the maxillary sinus: the bony window technique.

    PubMed

    Biglioli, Federico; Chiapasco, Matteo

    2014-12-01

    To present the authors' experience concerning the removal of dental implants displaced in the maxillary sinus via an intraoral approach consisting of the creation of a bony window pedicled to the maxillary sinus membrane. Thirty-six systemically healthy patients, presenting with oral implants displaced into the maxillary sinus, but with no signs of acute or chronic sinusitis, were consecutively treated between 2002 and 2012 via an intraoral approach with the bony window technique. Removal of oral implants from the maxillary sinus was achieved in all patients, and postoperative recovery was uneventful in all of them. Computed tomographies performed after surgery showed no signs of residual sinus infection in all patients and a complete ossification of the bony window margins. Twelve of the 36 treated patients were treated with a sinus grafting procedure 12-18 months after in the same areas previously treated with the bone lid technique. Seventeen implants were placed in the grafted areas 6-9 months later and, after a further waiting period needed for osseointegration, the treated patients were rehabilitated with implant-supported prostheses. The survival rate of implants was 100%, and no complications related to the sinuses and implants were recorded. Results from this study seem to demonstrate that the bony window technique is a safe and easy way to remove oral implants from the maxillary sinus under local anesthesia. The surgical access is hardly visible 6-12 months after surgery, and maxillary sinuses appeared free from residual pathology in all treated patients. Finally, this procedure allows a second-stage sinus grafting procedure via a lateral approach as in a previously untreated maxillary sinus, thus allowing an implant-supported prosthetic restoration. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Microsystems Technology for Retinal Implants

    NASA Astrophysics Data System (ADS)

    Weiland, James

    2005-03-01

    The retinal prosthesis is targeted to treat age-related macular degeneration, retinitis pigmentosa, and other outer retinal degenerations. Simulations of artificial vision have predicted that 600-1000 individual pixels will be needed if a retinal prosthesis is to restore function such as reading large print and face recognition. An implantable device with this many electrode contacts will require microsystems technology as part of its design. An implantable retinal prosthesis will consist of several subsystems including an electrode array and hermetic packaging. Microsystems and microtechnology approaches are being investigated as possible solutions for these design problems. Flexible polydimethylsiloxane (PDMS) substrate electrode arrays and silicon micromachined electrode arrays are under development. Inactive PDMS electrodes have been implanted in 3 dogs to assess mechanical biocompatibility. 3 dogs were followed for 6 months. The implanted was securely fastened to the retina with a single retinal tack. No post-operative complications were evident. The array remained within 100 microns of the retinal surface. Histological evaluation showed a well preserved retina underneath the electrode array. A silicon device with electrodes suspended on micromachined springs has been implanted in 4 dogs (2 acute implants, 2 chronic implants). The device, though large, could be inserted into the eye and positioned on the retina. Histological analysis of the retina from the spring electrode implants showed that spring mounted posts penetrated the retina, thus the device will be redesigned to reduce the strength of the springs. These initial implants will provide information for the designers to make the next generation silicon device. We conclude that microsystems technology has the potential to make possible a retinal prosthesis with 1000 individual contacts in close proximity to the retina.

  14. Multichannel cochlear implantation in the scala vestibuli.

    PubMed

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  15. Chronic multichannel neural recordings from soft regenerative microchannel electrodes during gait

    NASA Astrophysics Data System (ADS)

    Musick, Katherine M.; Rigosa, Jacopo; Narasimhan, Shreya; Wurth, Sophie; Capogrosso, Marco; Chew, Daniel J.; Fawcett, James W.; Micera, Silvestro; Lacour, Stéphanie P.

    2015-09-01

    Reliably interfacing a nerve with an electrode array is one of the approaches to restore motor and sensory functions after an injury to the peripheral nerve. Accomplishing this with current technologies is challenging as the electrode-neuron interface often degrades over time, and surrounding myoelectric signals contaminate the neuro-signals in awake, moving animals. The purpose of this study was to evaluate the potential of microchannel electrode implants to monitor over time and in freely moving animals, neural activity from regenerating nerves. We designed and fabricated implants with silicone rubber and elastic thin-film metallization. Each implant carries an eight-by-twelve matrix of parallel microchannels (of 120 × 110 μm2 cross-section and 4 mm length) and gold thin-film electrodes embedded in the floor of ten of the microchannels. After sterilization, the soft, multi-lumen electrode implant is sutured between the stumps of the sciatic nerve. Over a period of three months and in four rats, the microchannel electrodes recorded spike activity from the regenerating sciatic nerve. Histology indicates mini-nerves formed of axons and supporting cells regenerate robustly in the implants. Analysis of the recorded spikes and gait kinematics over the ten-week period suggests firing patterns collected with the microchannel electrode implant can be associated with different phases of gait.

  16. Utilization of implantable defibrillators in Africa.

    PubMed

    Millar, R N Scott; Mayosi, B M

    2003-01-01

    Sub-Saharan Africa is dominated by diseases of poverty. HIV/AIDS affects 28.5 out of a total of 600 million in the region. South Africa is the only country in sub-Saharan Africa in which implantable cardiovertor defibrillators (ICDs) are implanted (0.8/million in 2001). Only 3 of the 35 new ICDs were implanted in state-funded public hospitals. The pacemaker implantation rate for South Africa was 41/million in 2001. Approximately 20% of the population consume 56% of the health care expenditure, mainly funded by Medical Insurance. A tax-funded state health care system serves the rest of the population, but is concentrated on improving sanitation and primary health care. Diversion of funds from academic tertiary hospitals has reduced specialised services, particularly cardiology and cardiac surgery, and has resulted in an exodus of skilled personnel to the private sector. In the rest of sub-Saharan Africa, tertiary health care is mainly privately funded. Cardiology and cardiac surgery is not widely available. Many countries are crippled by debt and chronic local conflicts. Only one state hospital (Groote Schuur, Cape Town) provides an electrophysiology (EP) service including catheter ablation and ICD implantation, and training in EP, by two electrophysiologists. EP services are available privately in 3 centres. No EP service exists in the rest of sub-Saharan Africa.

  17. Alkaline Phosphatase Protects Lipopolysaccharide-Induced Early Pregnancy Defects in Mice

    PubMed Central

    Lei, Wei; Ni, Hua; Herington, Jennifer; Reese, Jeff; Paria, Bibhash C.

    2015-01-01

    Excessive cytokine inflammatory response due to chronic or superphysiological level of microbial infection during pregnancy leads to pregnancy complications such as early pregnancy defects/loss and preterm birth. Bacterial toxin lipopolysaccharide (LPS), long recognized as a potent proinflammatory mediator, has been identified as a risk factor for pregnancy complications. Alkaline phosphatase (AP) isozymes have been shown to detoxify LPS by dephosphorylation. In this study, we examined the role of alkaline phosphatase (AP) in mitigating LPS-induced early pregnancy complications in mice. We found that 1) the uterus prior to implantation and implantation sites following embryo implantation produce LPS recognition and dephosphorylation molecules TLR4 and tissue non-specific AP (TNAP) isozyme, respectively; 2) uterine TNAP isozyme dephosphorylates LPS at its sites of production; 3) while LPS administration following embryo implantation elicits proinflammatory cytokine mRNA levels at the embryo implantation sites (EISs) and causes early pregnancy loss, dephosphorylated LPS neither triggers proinflammatory cytokine mRNA levels at the EISs nor induces pregnancy complications; 4) AP isozyme supplementation to accelerate LPS detoxification attenuates LPS-induced pregnancy complications following embryo implantation. These findings suggest that a LPS dephosphorylation strategy using AP isozyme may have a unique therapeutic potential to mitigate LPS- or Gram-negative bacteria-induced pregnancy complications in at-risk women. PMID:25910276

  18. Alkaline phosphatase protects lipopolysaccharide-induced early pregnancy defects in mice.

    PubMed

    Lei, Wei; Ni, Hua; Herington, Jennifer; Reese, Jeff; Paria, Bibhash C

    2015-01-01

    Excessive cytokine inflammatory response due to chronic or superphysiological level of microbial infection during pregnancy leads to pregnancy complications such as early pregnancy defects/loss and preterm birth. Bacterial toxin lipopolysaccharide (LPS), long recognized as a potent proinflammatory mediator, has been identified as a risk factor for pregnancy complications. Alkaline phosphatase (AP) isozymes have been shown to detoxify LPS by dephosphorylation. In this study, we examined the role of alkaline phosphatase (AP) in mitigating LPS-induced early pregnancy complications in mice. We found that 1) the uterus prior to implantation and implantation sites following embryo implantation produce LPS recognition and dephosphorylation molecules TLR4 and tissue non-specific AP (TNAP) isozyme, respectively; 2) uterine TNAP isozyme dephosphorylates LPS at its sites of production; 3) while LPS administration following embryo implantation elicits proinflammatory cytokine mRNA levels at the embryo implantation sites (EISs) and causes early pregnancy loss, dephosphorylated LPS neither triggers proinflammatory cytokine mRNA levels at the EISs nor induces pregnancy complications; 4) AP isozyme supplementation to accelerate LPS detoxification attenuates LPS-induced pregnancy complications following embryo implantation. These findings suggest that a LPS dephosphorylation strategy using AP isozyme may have a unique therapeutic potential to mitigate LPS- or Gram-negative bacteria-induced pregnancy complications in at-risk women.

  19. Kinematic and fatigue biomechanics of an interpositional facet arthroplasty device.

    PubMed

    Dahl, Michael C; Freeman, Andrew L

    2016-04-01

    Although approximately 30% of chronic lumbar pain can be attributed to the facets, limited surgical options exist for patients. Interpositional facet arthroplasty (IFA) is a novel treatment for lumbar facetogenic pain designed to provide patients who gain insufficient relief from medical interventional treatment options with long-term relief, filling a void in the facet pain treatment continuum. This study aimed to quantify the effect of IFA on segmental range of motion (ROM) compared with the intact state, and to observe device position and condition after 10,000 cycles of worst-case loading. In situ biomechanical analysis of the lumbar spine following implantation of a novel IFA device was carried out. Twelve cadaveric functional spinal units (L2-L3 and L5-S1) were tested in 7.5 Nm flexion-extension, lateral bending, and torsion while intact and following device implantation. Additionally, specimens underwent 10,000 cycles of worst-case complex loading and were testing in ROM again. Load-displacement and fluoroscopic data were analyzed to determine ROM and to evaluate device position during cyclic testing. Devices and facets were evaluated post testing. Institutional support for implant evaluation was received by Zyga Technology. Range of motion post implantation decreased versus intact, and then was restored post cyclic-testing. Of the tested devices, 6.5% displayed slight movement (0.5-2 mm), all from tight L2-L3 facet joints with misplaced devices or insufficient cartilage. No damage was observed on the devices, and wear patterns were primarily linear. The results from this in situ cadaveric biomechanics and cyclic fatigue study demonstrate that a low-profile, conformable IFA device can maintain position and facet functionality post implantation and through 10,000 complex loading cycles. In vivo conditions were not accounted for in this model, which may affect implant behavior not predictable via a biomechanical study. However, these data along with published 1-year clinical results suggest that IFA may be a valid treatment option in patients with chronic lumbar zygapophysial pain who have exhausted medical interventional options. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Encoding of the amplitude modulation of pulsatile electrical stimulation in the feline cochlear nucleus by neurons in the inferior colliculus; effects of stimulus pulse rate

    NASA Astrophysics Data System (ADS)

    McCreery, Douglas; Han, Martin; Pikov, Victor; Yadav, Kamal; Pannu, Satinderpall

    2013-10-01

    Objectives. Persons without a functional auditory nerve cannot benefit from cochlear implants, but some hearing can be restored by an auditory brainstem implant (ABI) with stimulating electrodes implanted on the surface of the cochlear nucleus (CN). Most users benefit from their ABI, but speech recognition tends to be poorer than for users of cochlear implants. Psychophysical studies suggest that poor modulation detection may contribute to the limited performance of ABI users. In a cat model, we determined how the pulse rate of the electrical stimulus applied within or on the CN affects temporal and rate encoding of amplitude modulation (AM) by neurons in the central nucleus of the inferior colliculus (ICC). Approach. Stimulating microelectrodes were implanted chronically in and on the cats' CN, and multi-site recording microelectrodes were implanted chronically into the ICC. Encoding of AM pulse trains by neurons in the ICC was characterized as vector strength (VS), the synchrony of neural activity with the AM, and as the mean rate of neuronal action potentials (neuronal spike rate (NSR)). Main results. For intranuclear microstimulation, encoding of AM as VS was up to 3 dB greater when stimulus pulse rate was increased from 250 to 500 pps, but only for neuronal units with low best acoustic frequencies, and when the electrical stimulation was modulated at low frequencies (10-20 Hz). For stimulation on the surface of the CN, VS was similar at 250 and 500 pps, and the dynamic range of the VS was reduced for pulse rates greater than 250 pps. Modulation depth was encoded strongly as VS when the maximum stimulus amplitude was held constant across a range of modulation depth. This ‘constant maximum’ protocol allows enhancement of modulation depth while preserving overall dynamic range. However, modulation depth was not encoded as strongly as NSR. Significance. The findings have implications for improved sound processors for present and future ABIs. The performance of ABIs may benefit from using pulse rates greater than those presently used in most ABIs, and by sound processing strategies that enhance the modulation depth of the electrical stimulus while preserving dynamic range.

  1. Prostaglandins and reproduction in female farm animals.

    PubMed

    Weems, C W; Weems, Y S; Randel, R D

    2006-03-01

    Prostaglandins impact on ovarian, uterine, placental, and pituitary function to regulate reproduction in female livestock. They play important roles in ovulation, luteal function, maternal recognition of pregnancy, implantation, maintenance of gestation, microbial-induced abortion, parturition, postpartum uterine and ovarian infections, and resumption of postpartum ovarian cyclicity. Prostaglandins have both positive and negative effects on reproduction; they are used to synchronize oestrus, terminate pseudopregnancy in mares, induce parturition, and treat retained placenta, luteinized cysts, pyometra, and chronic endometritis. Improved therapeutic uses for prostaglandins will be developed when we understand better their involvement in implantation, maintenance of luteal function, and establishment and maintenance of pregnancy.

  2. [Fluocinolone acetonide (ILUVIEN®) micro-implant for chronic diabetic macular edema].

    PubMed

    Soubrane, G; Behar-Cohen, F

    2015-02-01

    Diabetic macular edema (DME) is a frequent complication of diabetic retinopathy and may cause severe visual loss. In this article, we examine the pathophysiology of DME and review various treatment options, such as laser photocoagulation, anti-vascular endothelial growth factor (VEGF) receptor antibodies, and steroids including ILUVIEN(®), which is a new sustained-release, non biodegradable, injectable, intravitreal micro-implant containing fluocinolone acetonide. The results of the FAME (Fluocinolone Acetonide in Diabetic Macular Edema) studies, conducted to evaluate the efficacy and safety of ILUVIEN(®) in DME, are discussed. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  3. Chronic recording of regenerating VIIIth nerve axons with a sieve electrode

    NASA Technical Reports Server (NTRS)

    Mensinger, A. F.; Anderson, D. J.; Buchko, C. J.; Johnson, M. A.; Martin, D. C.; Tresco, P. A.; Silver, R. B.; Highstein, S. M.

    2000-01-01

    A micromachined silicon substrate sieve electrode was implanted within transected toadfish (Opsanus tau) otolith nerves. High fidelity, single unit neural activity was recorded from seven alert and unrestrained fish 30 to 60 days after implantation. Fibrous coatings of genetically engineered bioactive protein polymers and nerve guide tubes increased the number of axons regenerating through the electrode pores when compared with controls. Sieve electrodes have potential as permanent interfaces to the nervous system and to bridge missing connections between severed or damaged nerves and muscles. Recorded impulses might also be amplified and used to control prosthetic devices.

  4. Multi-layered poly-dimethylsiloxane as a non-hermetic packaging material for medical MEMS.

    PubMed

    Lachhman, S; Zorman, C A; Ko, W H

    2012-01-01

    Poly-dimethylsiloxane (PDMS) is an attractive material for packaging implantable biomedical microdevices owing to its biocompatibility, ease in application, and bio-friendly mechanical properties. Unfortunately, devices encapsulated solely by PDMS lack the longevity for use in chronic implant applications due to defect-related moisture penetration through the packaging layer caused by conventional deposition processes such as spin coating. This paper describes an effort to improve the performance of PDMS as a packaging material by constructing the encapsulant from multiple, thin roller casted layers of PDMS as a part of a polymeric multi-material package.

  5. Neurofeedback control in Parkinsonian patients using electrocortigraphy signals accessed wirelessly with a chronic, fully implanted device

    PubMed Central

    Khanna, Preeya; Swann, Nicole C.; de Hemptinne, Coralie; Miocinovic, Svjetlana; Miller, Andrew; Starr, Philip A.; Carmena, Jose M.

    2017-01-01

    Parkinson’s disease (PD) is characterized by motor symptoms such as rigidity and bradykinesia that prevent normal movement. Beta band oscillations (13–30 Hz) in neural local field potentials (LFPs) have been associated with these motor symptoms. Here, three PD patients implanted with a therapeutic deep brain neural stimulator that can also record and wirelessly stream neural data played a neurofeedback game where they modulated their beta band power from sensorimotor cortical areas. Patients’ beta band power was streamed in real-time to update the position of a cursor that they tried to drive into a cued target. After playing the game for 1–2 hours each, all three patients exhibited above chance-level performance regardless of subcortical stimulation levels. This study, for the first time, demonstrates using an invasive neural recording system for at-home neurofeedback training. Future work will investigate chronic neurofeedback training as a potentially therapeutic tool for patients with neurological disorders. PMID:28113590

  6. Neurofeedback Control in Parkinsonian Patients Using Electrocorticography Signals Accessed Wirelessly With a Chronic, Fully Implanted Device.

    PubMed

    Khanna, Preeya; Swann, Nicole C; de Hemptinne, Coralie; Miocinovic, Svjetlana; Miller, Andrew; Starr, Philip A; Carmena, Jose M

    2017-10-01

    Parkinson's disease (PD) is characterized by motor symptoms such as rigidity and bradykinesia that prevent normal movement. Beta band oscillations (13-30 Hz) in neural local field potentials (LFPs) have been associated with these motor symptoms. Here, three PD patients implanted with a therapeutic deep brain neural stimulator that can also record and wirelessly stream neural data played a neurofeedback game where they modulated their beta band power from sensorimotor cortical areas. Patients' beta band power was streamed in real-time to update the position of a cursor that they tried to drive into a cued target. After playing the game for 1-2 hours each, all three patients exhibited above chance-level performance regardless of subcortical stimulation levels. This study, for the first time, demonstrates using an invasive neural recording system for at-home neurofeedback training. Future work will investigate chronic neurofeedback training as a potentially therapeutic tool for patients with neurological disorders.

  7. Bioengineered constructs combined with exercise enhance stem cell-mediated treatment of volumetric muscle loss

    PubMed Central

    Quarta, Marco; Cromie, Melinda; Chacon, Robert; Blonigan, Justin; Garcia, Victor; Akimenko, Igor; Hamer, Mark; Paine, Patrick; Stok, Merel; Shrager, Joseph B.; Rando, Thomas A.

    2017-01-01

    Volumetric muscle loss (VML) is associated with loss of skeletal muscle function, and current treatments show limited efficacy. Here we show that bioconstructs suffused with genetically-labelled muscle stem cells (MuSCs) and other muscle resident cells (MRCs) are effective to treat VML injuries in mice. Imaging of bioconstructs implanted in damaged muscles indicates MuSCs survival and growth, and ex vivo analyses show force restoration of treated muscles. Histological analysis highlights myofibre formation, neovascularisation, but insufficient innervation. Both innervation and in vivo force production are enhanced when implantation of bioconstructs is followed by an exercise regimen. Significant improvements are also observed when bioconstructs are used to treat chronic VML injury models. Finally, we demonstrate that bioconstructs made with human MuSCs and MRCs can generate functional muscle tissue in our VML model. These data suggest that stem cell-based therapies aimed to engineer tissue in vivo may be effective to treat acute and chronic VML. PMID:28631758

  8. Chronic subdural electrodes in the management of epilepsy.

    PubMed

    Nair, Dileep R; Burgess, Richard; McIntyre, Cameron C; Lüders, Hans

    2008-01-01

    Subdural electrodes play a very important role in the evaluation of a percentage of patients being considered for epilepsy surgery. Electrical activity at very low and very high frequencies, beyond the practical range of scalp EEG, can be recorded subdurally and may contain considerable information not available non-invasively. The recording and stimulating procedures for using chronically implanted subdural electrodes to localize the epileptogenic zone and map eloquent functions of the human cortex are well established, and complication rates are low. Complications include infections, CSF leak, and focal neurologic deficits, all of which tend to be increased with a higher number of electrodes and longer duration of recordings. Careful consideration of the risks and benefits should be coupled with a firm hypothesis about the epileptogenic zone derived from the non-invasive components of the epilepsy workup to guide the decision about whether and where to implant subdural electrodes. When they are employed to answer a specific question in an individual patient, subdural electrodes can optimize the clinical outcome of a candidate for epilepsy surgery.

  9. Anti-inflammatory, Anti-estrogenic, and Anti-implantation Activity of Bergia suffruticosa (Delile) Fenzl

    PubMed Central

    Bind, Sandeep Kumar; Jivrajani, Mehul; Anandjiwala, Sheetal; Nivsarkar, Manish

    2015-01-01

    Background: Bergia suffruticosa (Delile) Fenzl (Syn. Bergia odorata Edgew) (Elatinaceae family) is used traditionally to repair bones and is applied as a poultice on sores. It is also used for stomach troubles and as an antidote to scorpion stings. So far, very little scientific work has been reported to validate its ethnomedical uses in the alleviation of pain, bone repair, etc., Objective: This study was designed to explore the anti-inflammatory and anti-implantation potential of n-hexane extract of B. suffruticosa whole plant in mice along with identification of its chemical constituents. Materials and Methods: n-Hexane extract of B. suffruticosa whole plant was screened for acute and chronic anti-inflammatory activity followed by an anti-estrogenic activity. Eventually, n-hexane extract was tested for anti-implantation activity by exploiting markers of uterine receptivity, lipid peroxidation, and superoxide enzyme activity. The extract was administered orally at a dose of 100 mg/kg body weight in each study. Results: Thin layer chromatography fingerprint profile of n-hexane extract revealed the presence of lupeol and β-sitosterol. The n-hexane extract reduced the edema by 80% in acute inflammation, whereas it reduced edema to 75% on the 5th day in chronic inflammation. The n-hexane extract reduced elevated malonaldehyde level from 6 to 2.5 nmol/g × 10−5 and increased superoxide dismutase enzyme activity from 0 to 350 units/g in treated animals on the 5th day of pregnancy. Moreover, extract decreased uterine weight from 0.33 to 0.2 g in estradiol treated animals. Conclusion: These results indicate that n-hexane extract of B. suffruticosa is having potent anti-inflammatory, anti-estrogenic, and anti-implantation activity. This is the first report of all the pharmacological activities of B. suffruticosa mentioned above. SUMMARY TLC fingerprint profile of n-hexane extract of Bergia suffruticosa whole plant revealed the presence of lupeol and β-sitosteroln-Hexane extract showed in vivo anti-inflammatory activity in both acute and chronic model of inflammation in ratsn-Hexane extract possess significant anti-estrogenic activityn-Hexane extract altered the levels superoxide anion radical and superoxide dismutase enzyme activity during the blastocyst implantationAnti-implantation activity of n-hexane extract is attributed to its anti-inflammatory and anti-estrogenic potential. Abbreviations used: TLC: Thin layer chromatography; LPO: Lipid peroxidation; SOD: Superoxide dismutase; B. suffruticosa: Bergia suffruticosa; TNF-α: Tumor necrosis factor-α; NO: Nitric oxide; IL-1: Interleukin-1; LIF: Leukemia inhibitory factor; CSF-1: Colony-stimulating factor; COX: Cyclooxygenase; SDS: Sodium dodecyl sulfate; IAEC: Animal House Ethics Committee; CPCSEA: Committee for the Purpose of Control and Supervision of Experiments on Animals; HBSS: Hank's balanced salt solution; MDA: Malonaldehyde; and TBA: Thiobarbituric acid. PMID:26929574

  10. Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites

    NASA Astrophysics Data System (ADS)

    Pothof, F.; Bonini, L.; Lanzilotto, M.; Livi, A.; Fogassi, L.; Orban, G. A.; Paul, O.; Ruther, P.

    2016-08-01

    Objective. Drug resistant focal epilepsy can be treated by resecting the epileptic focus requiring a precise focus localisation using stereoelectroencephalography (SEEG) probes. As commercial SEEG probes offer only a limited spatial resolution, probes of higher channel count and design freedom enabling the incorporation of macro and microelectrodes would help increasing spatial resolution and thus open new perspectives for investigating mechanisms underlying focal epilepsy and its treatment. This work describes a new fabrication process for SEEG probes with materials and dimensions similar to clinical probes enabling recording single neuron activity at high spatial resolution. Approach. Polyimide is used as a biocompatible flexible substrate into which platinum electrodes and leads are integrated with a minimal feature size of 5 μm. The polyimide foils are rolled into the cylindrical probe shape at a diameter of 0.8 mm. The resulting probe features match those of clinically approved devices. Tests in saline solution confirmed the probe stability and functionality. Probes were implanted into the brain of one monkey (Macaca mulatta), trained to perform different motor tasks. Suitable configurations including up to 128 electrode sites allow the recording of task-related neuronal signals. Main results. Probes with 32 and 64 electrode sites were implanted in the posterior parietal cortex. Local field potentials and multi-unit activity were recorded as early as one hour after implantation. Stable single-unit activity was achieved for up to 26 days after implantation of a 64-channel probe. All recorded signals showed modulation during task execution. Significance. With the novel probes it is possible to record stable biologically relevant data over a time span exceeding the usual time needed for epileptic focus localisation in human patients. This is the first time that single units are recorded along cylindrical polyimide probes chronically implanted 22 mm deep into the brain of a monkey, which suggests the potential usefulness of this probe for human applications.

  11. An in vivo study of the biocompatibility of classic and novel device materials on the central nervous system

    NASA Astrophysics Data System (ADS)

    Jaboro, Claudine

    2007-12-01

    Investigation of novel biomaterials is an essential part of the development of electrical stimulation and chemical drug delivery for biomedical applications. In evaluating biocompatibility, the material's surface and the tissue should both be analyzed to determine their interaction during neural exposure. This includes a material investigation of bulk sapphire substrate, platinum (Pt) deposited on sapphire substrate using magnetron sputtering and aluminum nitride (AlN) which was deposited on sapphire substrate using plasma source molecular beam epitaxy (PSMBE). Zinc titania coverslip glass and borosilicate glass were used as control materials. The materials were implanted for periods of 10, 28 and 90 days on the cortical surface of the brain in a rat animal model. The chronic implants were analyzed both pre- and post- implantation for device structure/tissue interactions down to the atomic level. The characterization techniques used to explore structural and chemical changes on or within the material included optical microscopy, atomic force microscopy (AFM) and x-ray photoelectron spectroscopy (XPS). Magnetic Resonance Imaging (MRI) and histology were used to determine the effects of the implants in vivo. Biocompatibility is the ability of a material or device to be exposed to the dynamic environment of the body and elicit little or no adverse effects. The data suggests that the biocompatibility of a material may be directly associated with structure and topology. The sapphire, zinc titania coverslip glass and platinum all had signs of bio-incompatibility. The aluminum nitride and borosilicate glass materials were both biocompatible based on our studies. The borosilicate glass elicited no response from the tissue while the aluminum nitride had a positive affect on the tissue encouraging the attachment of proteins and tissue without glial scars instigation. The material characterization, MR imaging and histological data show that surface features such as roughness in addition to chemical stability may have a direct effect on the neurocompatibility of the chronic implants.

  12. Current and Future Management of Bilateral Loss of Vestibular Sensation – An update on the Johns Hopkins Multichannel Vestibular Prosthesis Project

    PubMed Central

    Della Santina, Charles C.; Migliaccio, Americo A.; Hayden, Russell; Melvin, Thuy-Anh; Fridman, Gene Y.; Chiang, Bryce; Davidovics, Natan S.; Dai, Chenkai; Carey, John P.; Minor, Lloyd B.; Anderson, Iee-Ching; Park, HongJu; Lyford-Pike, Sofia; Tang, Shan

    2012-01-01

    Bilateral loss of vestibular sensation can disable individuals whose vestibular hair cells are injured by ototoxic medications, infection, Ménière’s disease or other insults to the labyrinth including surgical trauma during cochlear implantation. Without input to vestibulo-ocular and vestibulo-spinal reflexes that normally stabilize the eyes and body, affected patients suffer blurred vision during head movement, postural instability, and chronic disequilibrium. While individuals with some residual sensation often compensate for their loss through rehabilitation exercises, those who fail to do so are left with no adequate treatment options. An implantable neuroelectronic vestibular prosthesis that emulates the normal labyrinth by sensing head movement and modulating activity on appropriate branches of the vestibular nerve could significantly improve quality of life for these otherwise chronically dizzy patients. This brief review describes the impact and current management of bilateral loss of vestibular sensation, animal studies supporting the feasibility of prosthetic vestibular stimulation, and a vestibular prosthesis designed to restore sensation of head rotation in all directions. Similar to a cochlear implant in concept and size, the Johns Hopkins Multichannel Vestibular Prosthesis (MVP) includes miniature gyroscopes to sense head rotation, a microcontroller to process inputs and control stimulus timing, and current sources switched between pairs of electrodes implanted within the vestibular labyrinth. In rodents and rhesus monkeys rendered bilaterally vestibular-deficient via treatment with gentamicin and/or plugging of semicircular canals, the MVP partially restores the vestibulo-ocular reflex for head rotations about any axis of rotation in 3-dimensional space. Our efforts now focus on addressing issues prerequisite to human implantation, including refinement of electrode designs and surgical technique to enhance stimulus selectivity and preserve cochlear function, optimization of stimulus protocols, and reduction of device size and power consumption. PMID:21756683

  13. Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites.

    PubMed

    Pothof, F; Bonini, L; Lanzilotto, M; Livi, A; Fogassi, L; Orban, G A; Paul, O; Ruther, P

    2016-08-01

    Drug resistant focal epilepsy can be treated by resecting the epileptic focus requiring a precise focus localisation using stereoelectroencephalography (SEEG) probes. As commercial SEEG probes offer only a limited spatial resolution, probes of higher channel count and design freedom enabling the incorporation of macro and microelectrodes would help increasing spatial resolution and thus open new perspectives for investigating mechanisms underlying focal epilepsy and its treatment. This work describes a new fabrication process for SEEG probes with materials and dimensions similar to clinical probes enabling recording single neuron activity at high spatial resolution. Polyimide is used as a biocompatible flexible substrate into which platinum electrodes and leads are integrated with a minimal feature size of 5 μm. The polyimide foils are rolled into the cylindrical probe shape at a diameter of 0.8 mm. The resulting probe features match those of clinically approved devices. Tests in saline solution confirmed the probe stability and functionality. Probes were implanted into the brain of one monkey (Macaca mulatta), trained to perform different motor tasks. Suitable configurations including up to 128 electrode sites allow the recording of task-related neuronal signals. Probes with 32 and 64 electrode sites were implanted in the posterior parietal cortex. Local field potentials and multi-unit activity were recorded as early as one hour after implantation. Stable single-unit activity was achieved for up to 26 days after implantation of a 64-channel probe. All recorded signals showed modulation during task execution. With the novel probes it is possible to record stable biologically relevant data over a time span exceeding the usual time needed for epileptic focus localisation in human patients. This is the first time that single units are recorded along cylindrical polyimide probes chronically implanted 22 mm deep into the brain of a monkey, which suggests the potential usefulness of this probe for human applications.

  14. Intrathecal Hydromorphone and Bupivacaine Combination Therapy for Post-Laminectomy Syndrome Optimized with Patient-Activated Bolus Device.

    PubMed

    Hayek, Salim M; Veizi, Elias; Hanes, Michael

    2016-03-01

    Intrathecal (IT) pumps have become a valuable tool in managing intractable non-cancer pain. The purpose of this study was to evaluate the efficacy of using a rigorous treatment algorithm for trialing and implanting IT pumps with hydromorphone and bupivacaine in managing a more homogeneous population of post-laminectomy syndrome or failed back surgery syndrome (FBSS) patients. This is a retrospective analysis of FBSS patients with chronic intractable back pain implanted with IT pumps delivering hydromorphone and bupivacaine. A cohort of 57 (26 males, 31 females) consecutively implanted FBSS patients was analyzed. The average age at implant was 65.4 years. Average pain scores were 8.4 ± 0.2 (pre-implant), 4.9 ± 0.4 (6 months), 5.2 ± 0.5 (12 months), and 4.3 ± 0.5 (24 months). Average oral opioid doses in morphine equivalents were 56 ± 10 mg/day (pre-implant), 12.0 ± 3.5 mg/day (12 months), 15 ± 6 mg/day (24 months). Average IT hydromorphone doses were 79 ± 6.8 mcg/day (at implant), 184 ± 22 mcg/day (6 months), 329 ± 48 mcg/day (12 months), and 487 ± 80 mcg (24 months). IT hydromorphone dose escalation from baseline was 133% (6 months vs baseline), 78% (12 months vs 6 months), and 48% from 12 months to 24 months. Average IT bupivacaine doses were 5.8 ± 0.3 mg/day (implant), 9.5 ± 0.6 mg/day (6 months), 12.2 ± 0.7 mg/day (12 months), and 12.6 ± 0.9 mg/day (24 months). IT hydromorphone and bupivacaine are effective in treating chronic pain of FBSS, as demonstrated by the reduction of pain intensity and oral opioid consumption. However, an IT dose escalation phenomenon was observed, although at a reduced rate compared with what had been previously reported in the literature. It is possible that the local anesthetic combination delivered via a patient-activaed bolus device is an important factor. Despite demonstrating effectiveness, the clinical utility of myPTM-optimized IT therapy remains limited by a lack of prospective, placebo-controlled trials and comparative effectiveness research. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Exploring the tolerability of spatiotemporally complex electrical stimulation paradigms.

    PubMed

    Nelson, Timothy S; Suhr, Courtney L; Lai, Alan; Halliday, Amy J; Freestone, Dean R; McLean, Karen J; Burkitt, Anthony N; Cook, Mark J

    2011-10-01

    A modified cortical stimulation model was used to investigate the effects of varying the synchronicity and periodicity of electrical stimuli delivered to multiple pairs of electrodes on seizure initiation. In this model, electrical stimulation of the motor cortex of rats, along four pairs of a microwire electrode array, results in an observable seizure with quantifiable electrographic duration and behavioural severity. Periodic stimuli had a constant inter-stimulus intervals across the two-second stimulus duration, whilst synchronous stimuli consisted of singular biphasic, bipolar pulses delivered to the four pairs of electrodes at precisely the same time for the entire two second stimulation period. In this way four combinations of stimulation were possible; periodic/synchronous (P/S), periodic/asynchronous (P/As), aperiodic/synchronous (Ap/S) and aperiodic/asynchronous (Ap/As). All stimulation types were designed with equal pulse width, current intensity and mean frequency of stimulation (60 Hz), standardizing net charge transfer. It was expected that the periodicity of the stimulus would be the primary determinant of seizure initiation and therefore severity and electrographic duration. However, the results showed that significant differences in both severity and duration only occurred when the synchronicity was altered. For periodic stimuli, synchronous delivery increased median seizure duration from 5 s to 13 s and increased median Racine severity from 1 to 3. In the aperiodic case, synchronous stimulus delivery increased median duration from 5.5 s to 11s and resulted in seizures of median severity 3 vs. 0 in the asynchronous case. These findings may have implications for the design of future neurostimulation waveform designs as higher numbers of electrodes and stimulator output channels become available in next generation implants. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology

    PubMed Central

    Fu, Tian-Ming; Hong, Guosong; Viveros, Robert D.; Zhou, Tao

    2017-01-01

    Implantable electrical probes have led to advances in neuroscience, brain−machine interfaces, and treatment of neurological diseases, yet they remain limited in several key aspects. Ideally, an electrical probe should be capable of recording from large numbers of neurons across multiple local circuits and, importantly, allow stable tracking of the evolution of these neurons over the entire course of study. Silicon probes based on microfabrication can yield large-scale, high-density recording but face challenges of chronic gliosis and instability due to mechanical and structural mismatch with the brain. Ultraflexible mesh electronics, on the other hand, have demonstrated negligible chronic immune response and stable long-term brain monitoring at single-neuron level, although, to date, it has been limited to 16 channels. Here, we present a scalable scheme for highly multiplexed mesh electronics probes to bridge the gap between scalability and flexibility, where 32 to 128 channels per probe were implemented while the crucial brain-like structure and mechanics were maintained. Combining this mesh design with multisite injection, we demonstrate stable 128-channel local field potential and single-unit recordings from multiple brain regions in awake restrained mice over 4 mo. In addition, the newly integrated mesh is used to validate stable chronic recordings in freely behaving mice. This scalable scheme for mesh electronics together with demonstrated long-term stability represent important progress toward the realization of ideal implantable electrical probes allowing for mapping and tracking single-neuron level circuit changes associated with learning, aging, and neurodegenerative diseases. PMID:29109247

  17. Chronic lymphocytic leukemia skin infiltration mimicking an ICD pocket infection: a case report.

    PubMed

    Snorek, M; Bulava, A; Vonke, I

    2017-03-24

    We are presenting a case report on an unreported and unusual cutaneous manifestation of chronic lymphocytic leukemia in a patient with an implantable cardioverter-defibrillator (ICD). A 65-year-old man with a history of chronic lymphocytic leukemia (CLL), previously treated with chlorambucil, was referred in October 2013 for extraction of a single chamber ICD due to a suspected device-related infection in the pulse generator area (left-hand side of Fig. 1). The ICD system (Current VR, St. Jude Medical, USA) had been implanted in November 2009. The patient complained of painless erythema with pruritus in the pocket area. Inflammatory blood parameters were C-reactive protein 17.3 mg/L and leucocytes 29.0 × 10 9 /L. Due to the atypical appearance of the pocket area we did not extract the device. Instead, we created an exploratory excision in the skin induration, which had been present for approximately 6 weeks, and conducted a microbiological and histological examination. All cultivation examinations were negative. However, we did histologically show skin infiltration by CD-5 positive low-grade B-cell chronic lymphocytic leukemia/small lymphocytic lymphoma (B-CLL/SLL). Re-initiation of chemotherapy was not necessary and the skin induration completely disappeared within 2 months (right-hand side of Fig. 1). Complete removal of an ICD system carries considerable risk. In patients with a history of hematological disease, it is crucial to exclude cutaneous manifestations of the disease prior to device removal.

  18. The Use of Temporoparietal Fascial Flap to Eliminate Wound Breakdown in Subtotal Petrosectomy for Chronic Discharging Ears.

    PubMed

    Yung, Matthew

    2016-03-01

    To find out if the use of the vascularized temporo-parietal fascial flap (TPFF) reduces postoperative infection or wound breakdown in subtotal petrosectomy for chronic discharging ears. A retrospective review on 26 subtotal petrosectomies with blind pit closures on chronic discharging ears performed by a single surgeon between 2000 and 2015 was performed. All patients had a minimum follow-up period of 6 months. Eleven mastoid cavities were obliterated with abdominal fat, and 15 cavities were obliterated with TPFF. There was no concomitant cochlear implant or middle ear implant. All postoperative wound infections or delay in wound healing were recorded into a database. The complication rates of the fat obliteration group were compared using Fisher's exact test with those for the TPFF obliteration group. In the fat obliteration group, 4 out of 11 patients had documented postoperative complications. Three had wound breakdown with exposure of the fat that required revision surgery. Another patient had postauricular abscess without the wound actually broken down. On the other hand, all the ears in the TPFF obliteration group (100%) were completely free of wound infection, wound breakdown, or any complication. The difference between the two groups was statistically significant (p = 0.022). Many authors have encountered postoperative infection or wound breakdown in subtotal petrosectomy with fat obliteration in the treatment of chronic otitis media. Using a richly vascularized temporo-temporal fascial flap to protect the blind pit closure in such patients reduces postoperative infection and wound breakdown.

  19. Real-time in vivo detection of biomaterial-induced reactive oxygen species.

    PubMed

    Liu, Wendy F; Ma, Minglin; Bratlie, Kaitlin M; Dang, Tram T; Langer, Robert; Anderson, Daniel G

    2011-03-01

    The non-specific host response to implanted biomaterials is often a key challenge of medical device design. To evaluate biocompatibility, measuring the release of reactive oxygen species (ROS) produced by inflammatory cells in response to biomaterial surfaces is a well-established method. However, the detection of ROS in response to materials implanted in vivo has not yet been demonstrated. Here, we develop a bioluminescence whole animal imaging approach to observe ROS released in response to subcutaneously-implanted materials in live animals. We compared the real-time generation of ROS in response to two representative materials, polystyrene and alginate, over the course of 28 days. High levels of ROS were observed near polystyrene, but not alginate implants, and persisted throughout the course of 28 days. Histological analysis revealed that high levels of ROS correlated not only with the presence of phagocytic cells at early timepoints, but also fibrosis at later timepoints, suggesting that ROS may be involved in both the acute and chronic phase of the foreign body response. These data are the first in vivo demonstration of ROS generation in response to implanted materials, and describe a novel technique to evaluate the host response. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. Basal forebrain infusion of HC-3 in rats: maze learning deficits and neuropathology.

    PubMed

    Hurlbut, B J; Lubar, J F; Switzer, R; Dougherty, J; Eisenstadt, M L

    1987-01-01

    Ten adult male Sprague-Dawley rats were infused with hemicholinium (HC-3) using mini-osmotic pumps over a 14 day period through bilateral, chronically implanted cannulae in the nucleus basalis magnocellularis (nbm). Ten matched controls were infused in the same fashion with saline. HC-3 rats receiving implants demonstrated a significant deficit in maze-learning ability compared with individual and group performances before receiving the implants. In saline rats there was no significant difference in maze-learning ability before and after receiving implants. The HC-3 group receiving implants demonstrated a significant deficit in maze-learning ability compared with the saline control group. Serial sections through nbm from control and HC-3 rats indicated that all cannulae were located within infusion range of nbm. In HC-3 subjects, cholinergic cell bodies were destroyed with concurrent degeneration of terminal fields in cortex. Except for cannula insertion damage, the cholinergic neurotransmitter system appeared unharmed in controls. Stains for neuritic plaques and neurofibrillary damage were negative in both groups. The memory deficit in experimental subjects supported by the demonstrated destruction of nbm cholinergic neurons suggests that HC-3 may be useful in the development of an animal model for Alzheimer's Disease.

  1. Cutaneous and systemic hypersensitivity reactions to metallic implants.

    PubMed

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure. However, other metal ions as well as bone cement components can cause such hypersensitivity reactions. To complicate things, patients may also develop delayed-type hypersensitivity reactions to metals (ie, in-stent restenosis, prosthesis loosening, inflammation, pain, or allergic contact dermatitis) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions remains to be fully understood. This review provides an update of the current knowledge in this field and should be valuable to health care providers who manage patients with conditions related to this field.

  2. Tyrosine-based rivastigmine-loaded organogels in the treatment of Alzheimer’s disease

    PubMed Central

    Bastiat, Guillaume; Plourde, François; Motulsky, Aude; Furtos, Alexandra; Dumont, Yvan; Quirion, Rémi; Fuhrmann, Gregor; Leroux, Jean-Christophe

    2015-01-01

    Organogels can be prepared by immobilizing an organic phase into a three-dimensional network coming from the self-assembly of a low molecular weight gelator molecule. In this work, an injectable subcutaneous organogel system based on safflower oil and a modified-tyrosine organogelator was evaluated in vivo for the delivery of rivastigmine, an acetylcholinesterase (AChE) inhibitor used in the treatment of Alzheimer’s disease. Different implant formulations were injected and the plasmatic drug concentration was assayed for up to 35 days. In parallel, the inhibition of AChE in different brain sections and the biocompatibility of the implants were monitored. The pharmacokinetic profiles were found to be influenced by the gel composition, injected dose and volume of the implant. The sustained delivery of rivastigmine was accompanied by a significant prolonged inhibition of AChE in the hippocampus, a brain structure involved in memory. The implant induced only a minimal to mild chronic inflammation and fibrosis, which was comparable to poly(D,L-lactide-co-glycolide) in situ-forming implants. These findings suggest that tyrosine-based organogels could represent an alternative approach to current formulations for the sustained delivery of cholinesterase inhibitors. PMID:20472283

  3. In vitro and in vivo testing of a totally implantable left ventricular assist system.

    PubMed

    Jassawalla, J S; Daniel, M A; Chen, H; Lee, J; LaForge, D; Billich, J; Ramasamy, N; Miller, P J; Oyer, P E; Portner, P M

    1988-01-01

    The totally implantable Novacor LVAS is being tested under NIH auspices to demonstrate safety and efficacy before clinical trials. Twelve complete systems (submerged in saline at 37 degrees C) are being tested, with an NIH goal of demonstrating 80% reliability for 2 year operation with a 60% confidence level. The systems, which are continuously monitored, are diurnally cycled between two output levels by automatically varying preload and afterload. Currently, 14.3 years of failure-free operation have been accumulated, with a mean duration of 14 months. Using an exponential failure distribution model, the mean time to failure (MTTF) is greater than 8.8 years, corresponding to a demonstrated reliability (for a 2 year mission time) of 80% (80% confidence level). Recent ovine experiments with VAS subsystems include a 767 day volume compensator implant, a 279 day pump/drive unit implant and a 1,448 day BST implant. The last 12 chronic pump/drive unit experiments had a mean duration of 153 days (excluding early postoperative complications). This compares favorably with the NIH goals for complete systems (5 month mean duration). Complete system experiments are currently underway.

  4. A Wireless Implantable Switched-Capacitor Based Optogenetic Stimulating System

    PubMed Central

    Lee, Hyung-Min; Kwon, Ki-Yong; Li, Wen

    2015-01-01

    This paper presents a power-efficient implantable optogenetic interface using a wireless switched-capacitor based stimulating (SCS) system. The SCS efficiently charges storage capacitors directly from an inductive link and periodically discharges them into an array of micro-LEDs, providing high instantaneous power without affecting wireless link and system supply voltage. A custom-designed computer interface in LabVIEW environment wirelessly controls stimulation parameters through the inductive link, and an optrode array enables simultaneous neural recording along with optical stimulation. The 4-channel SCS system prototype has been implemented in a 0.35-μm CMOS process and combined with the optrode array. In vivo experiments involving light-induced local field potentials verified the efficacy of the SCS system. An implantable version of the SCS system with flexible hermetic sealing is under development for chronic experiments. PMID:25570099

  5. Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes

    NASA Astrophysics Data System (ADS)

    Ludwig, Kip A.; Langhals, Nicholas B.; Joseph, Mike D.; Richardson-Burns, Sarah M.; Hendricks, Jeffrey L.; Kipke, Daryl R.

    2011-02-01

    We investigated using poly(3,4-ethylenedioxythiophene) (PEDOT) to lower the impedance of small, gold recording electrodes with initial impedances outside of the effective recording range. Smaller electrode sites enable more densely packed arrays, increasing the number of input and output channels to and from the brain. Moreover, smaller electrode sizes promote smaller probe designs; decreasing the dimensions of the implanted probe has been demonstrated to decrease the inherent immune response, a known contributor to the failure of long-term implants. As expected, chronically implanted control electrodes were unable to record well-isolated unit activity, primarily as a result of a dramatically increased noise floor. Conversely, electrodes coated with PEDOT consistently recorded high-quality neural activity, and exhibited a much lower noise floor than controls. These results demonstrate that PEDOT coatings enable electrode designs 15 µm in diameter.

  6. Minimal adverse effects profile following implantation of periauricular percutaneous electrical nerve field stimulators: a retrospective cohort study

    PubMed Central

    Roberts, Arthur; Sithole, Alec; Sedghi, Marcos; Walker, Charles A; Quinn, Theresa M

    2016-01-01

    The periauricular percutaneous implantation of the Neuro-Stim System™ family of devices EAD, MFS, and BRIDGE is a procedure involving the use of a non-opiate, neuromodulation analgesic for relieving acute and chronic pain. It has been approved as a minimal-risk procedure by multiple governmental and institutional facilities. This retrospective report of findings will help quantify the incidence of clinically observed bleeding, localized dermatitis, and infections at the implantation sites of the electrode/needle arrays, dermatitis at the site of the generator, and patient syncope. A total of 1,207 devices, each producing up to 16 percutaneous punctures, for a total of 19,312 punctures were monitored for adverse effects, based on retrospective chart audits conducted at six clinical facilities over a 1-year period. PMID:27843360

  7. Assessment of Patients' Perception of Telemedicine Services Using the Service User Technology Acceptability Questionnaire.

    PubMed

    Dario, Claudio; Luisotto, Elena; Dal Pozzo, Enrico; Mancin, Silvia; Aletras, Vassilis; Newman, Stanton; Gubian, Lorenzo; Saccavini, Claudio

    2016-06-01

    The purpose of this paper is to assess if similar telemedicine services integrated in the management of different chronic diseases are acceptable and well perceived by patients or if there are any negative perceptions. Participants suffering from different chronic diseases were enrolled in Veneto Region and gathered into clusters. Each cluster received a similar telemedicine service equipped with different disease-specific measuring devices. Participants were patients with diabetes (n = 163), chronic obstructive pulmonary disease (n = 180), congestive heart failure (n = 140) and Cardiac Implantable Electronic Devices (n = 1635). The Service User Technology Acceptability Questionnaire (SUTAQ) was initially translated, culturally adapted and pretested and subsequently used to assess patients' perception of telemedicine. Data were collected after 3 months and after 12 months from the beginning of the intervention. Data for patients with implantable devices was collected only at 12 months. Results at 12 months for all clusters are similar and assessed a positive perception of telemedicine. The SUTAQ results for clusters 2 (diabetes), 5 (COPD) and 7 (CHF) after 3 months of intervention were confirmed after 12 months. Telemedicine was perceived as a viable addition to usual care. A positive perception for telemedicine services isn't a transitory effect, but extends over the course of time.

  8. Electroencephalographic responses to ionizing radiation.

    PubMed

    GARCIA, J; BUCHWALD, N A; BACH-Y-RITA, G; FEDER, B H; KOELLING, R A

    1963-04-19

    Electroencephalographic recordings made from chronically implanted cortical electrodes indicate that ionizing radiation has an immediate effect upon brain wave patterns. X-rays delivered at the rate of 0.2 roentgen per second produce an arousal effect resembling that which occurs as a result of stimulation through peripheral receptor systems.

  9. Inadvertent positioning of pacemaker leads in the pericardium.

    PubMed

    Berenji, Kambeez; Nerheim, Pamela; Olshansky, Brian

    2003-10-01

    A patient had a dual chamber pacemaker with endocardial leads implanted chronically. The lead position on chest X ray and the ECG pattern indicated lead malposition, but a CT scan and transesophageal echocardiography were nondiagnostic. Venography indicated that both leads were in the mediastinal and pericardial space.

  10. Long-term outcomes of phakic patients with diabetic macular oedema treated with intravitreal fluocinolone acetonide (FAc) implants

    PubMed Central

    Yang, Y; Bailey, C; Holz, F G; Eter, N; Weber, M; Baker, C; Kiss, S; Menchini, U; Ruiz Moreno, J M; Dugel, P; Lotery, A

    2015-01-01

    Purpose Diabetic macular oedema (DMO) is a leading cause of blindness in working-age adults. Slow-release, nonbioerodible fluocinolone acetonide (FAc) implants have shown efficacy in the treatment of DMO; however, the National Institute for Health and Care Excellence recommends that FAc should be used in patients with chronic DMO considered insufficiently responsive to other available therapies only if the eye to be treated is pseudophakic. The goal of this analysis was to examine treatment outcomes in phakic patients who received 0.2 μg/day FAc implant. Methods This analysis of the phase 3 FAME (Fluocinolone Acetonide in Diabetic Macular Edema) data examines the safety and efficacy of FAc implants in patients who underwent cataract extraction before (cataract before implant (CBI) group) or after (cataract after implant (CAI) group) receiving the implant. The data were further examined by DMO duration. Results Best corrected visual acuity (BCVA) after 36 months was comparable in the CAI and CBI groups. Both the percentage of patients gaining ≥3 lines of vision and mean change in BCVA letter score were numerically greater in the CAI group. In addition, most patients who underwent cataract surgery experienced a net gain in BCVA from presurgery baseline as well as from original study baseline. Conclusions These data support the use of 0.2 μg/day FAc implants in phakic as well as in pseudophakic patients. These findings will serve as a pilot for design of future studies to evaluate the potential protective effect of FAc implants before cataract surgery in patients with DMO and cataract. PMID:26113503

  11. Ultrathin, transferred layers of thermally grown silicon dioxide as biofluid barriers for biointegrated flexible electronic systems.

    PubMed

    Fang, Hui; Zhao, Jianing; Yu, Ki Jun; Song, Enming; Farimani, Amir Barati; Chiang, Chia-Han; Jin, Xin; Xue, Yeguang; Xu, Dong; Du, Wenbo; Seo, Kyung Jin; Zhong, Yiding; Yang, Zijian; Won, Sang Min; Fang, Guanhua; Choi, Seo Woo; Chaudhuri, Santanu; Huang, Yonggang; Alam, Muhammad Ashraful; Viventi, Jonathan; Aluru, N R; Rogers, John A

    2016-10-18

    Materials that can serve as long-lived barriers to biofluids are essential to the development of any type of chronic electronic implant. Devices such as cardiac pacemakers and cochlear implants use bulk metal or ceramic packages as hermetic enclosures for the electronics. Emerging classes of flexible, biointegrated electronic systems demand similar levels of isolation from biofluids but with thin, compliant films that can simultaneously serve as biointerfaces for sensing and/or actuation while in contact with the soft, curved, and moving surfaces of target organs. This paper introduces a solution to this materials challenge that combines (i) ultrathin, pristine layers of silicon dioxide (SiO 2 ) thermally grown on device-grade silicon wafers, and (ii) processing schemes that allow integration of these materials onto flexible electronic platforms. Accelerated lifetime tests suggest robust barrier characteristics on timescales that approach 70 y, in layers that are sufficiently thin (less than 1 μm) to avoid significant compromises in mechanical flexibility or in electrical interface fidelity. Detailed studies of temperature- and thickness-dependent electrical and physical properties reveal the key characteristics. Molecular simulations highlight essential aspects of the chemistry that governs interactions between the SiO 2 and surrounding water. Examples of use with passive and active components in high-performance flexible electronic devices suggest broad utility in advanced chronic implants.

  12. Examination of a novel, specified local antibiotic therapy through polymethylmethacrylate capsules in a rabbit osteomyelitis model.

    PubMed

    Börzsei, László; Mintál, Tibor; Koós, Zoltán; Kocsis, Béla; Helyes, Zsuzsanna; Kereskai, László; Nyárády, József

    2006-01-01

    Chronic bone and soft tissue suppurations have become more frequent recently due to the increasing number of high-energy injuries. There are certain antibiotic beads available for local administration, but they cannot always be applied specifically against the pyogenic microorganisms. In the present study, a new technique of local antibiotic therapy for the treatment of infections is described. Polymethylmethacrylate (PMMA) capsules were produced and filled with 0.1 ml Tazocin (0.02 g piperacillin sodium + 0.005 g tazobactam). The efficacy of these Tazocin-filled capsules was examined in vivo using a rabbit osteomyelitis model. Chronic osteomyelitis was induced in rabbit tibia by local injection of Staphylococcus aureus. The treatment included surgical debridement and implantation of Tazocin-containing PMMA capsules into the medullar cavity (n = 12). Simple surgical debridement with no antibiotic implantation was performed in control animals (n = 7). Results were evaluated using microbiological, radiological and histological methods 14 weeks after induction of osteomyelitis. Eight weeks after the implantation of PMMA capsules, complete physical, radiological and histological healing was achieved in 7 animals, initiation of the reparative phase was observed histologically in 3 cases and no reparative signs were detected in 2 rabbits. In the control group, no significant sign of reparation could be seen in any of the cases. Copyright 2006 S. Karger AG, Basel.

  13. Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve.

    PubMed

    Fisher, L E; Tyler, D J; Anderson, J S; Triolo, R J

    2009-08-01

    This study describes the stability and selectivity of four-contact spiral nerve-cuff electrodes implanted bilaterally on distal branches of the femoral nerves of a human volunteer with spinal cord injury as part of a neuroprosthesis for standing and transfers. Stimulation charge threshold, the minimum charge required to elicit a visible muscle contraction, was consistent and low (mean threshold charge at 63 weeks post-implantation: 23.3 +/- 8.5 nC) for all nerve-cuff electrode contacts over 63 weeks after implantation, indicating a stable interface with the peripheral nervous system. The ability of individual nerve-cuff electrode contacts to selectively stimulate separate components of the femoral nerve to activate individual heads of the quadriceps was assessed with fine-wire intramuscular electromyography while measuring isometric twitch knee extension moment. Six of eight electrode contacts could selectively activate one head of the quadriceps while selectively excluding others to produce maximum twitch responses of between 3.8 and 8.1 N m. The relationship between isometric twitch and tetanic knee extension moment was quantified, and selective twitch muscle responses scaled to between 15 and 35 N m in tetanic response to pulse trains with similar stimulation parameters. These results suggest that this nerve-cuff electrode can be an effective and chronically stable tool for selectively stimulating distal nerve branches in the lower extremities for neuroprosthetic applications.

  14. Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve

    PubMed Central

    Fisher, L E; Tyler, D J; Anderson, J S; Triolo, R J

    2010-01-01

    This study describes the stability and selectivity of four-contact spiral nerve-cuff electrodes implanted bilaterally on distal branches of the femoral nerves of a human volunteer with spinal cord injury as part of a neuroprosthesis for standing and transfers. Stimulation charge threshold, the minimum charge required to elicit a visible muscle contraction, was consistent and low (mean threshold charge at 63 weeks post-implantation: 23.3 ± 8.5 nC) for all nerve-cuff electrode contacts over 63 weeks after implantation, indicating a stable interface with the peripheral nervous system. The ability of individual nerve-cuff electrode contacts to selectively stimulate separate components of the femoral nerve to activate individual heads of the quadriceps was assessed with fine-wire intramuscular electromyography while measuring isometric twitch knee extension moment. Six of eight electrode contacts could selectively activate one head of the quadriceps while selectively excluding others to produce maximum twitch responses of between 3.8 and 8.1 Nm. The relationship between isometric twitch and tetanic knee extension moment was quantified, and selective twitch muscle responses scaled to between 15 and 35 Nm in tetanic response to pulse trains with similar stimulation parameters. These results suggest that this nerve-cuff electrode can be an effective and chronically stable tool for selectively stimulating distal nerve branches in the lower extremities for neuroprosthetic applications. PMID:19602729

  15. A 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications

    PubMed Central

    Yin, Ming; Borton, David A.; Aceros, Juan; Patterson, William R.; Nurmikko, Arto V.

    2014-01-01

    A 100-channel fully implantable wireless broadband neural recording system was developed. It features 100 parallel broadband (0.1 Hz–7.8 kHz) neural recording channels, a medical grade 200 mAh Li-ion battery recharged inductively at 150 kHz, and data telemetry using 3.2 GHz to 3.8 GHz FSK modulated wireless link for 48 Mbps Manchester encoded data. All active electronics are hermetically sealed in a titanium enclosure with a sapphire window for electromagnetic transparency. A custom, high-density configuration of 100 individual hermetic feedthrough pins enable connection to an intracortical neural recording microelectrode array. A 100 MHz bandwidth custom receiver was built to remotely receive the FSK signal and achieved −77.7 dBm sensitivity with 10−8 BER at 48 Mbps data rate. ESD testing on all the electronic inputs and outputs has proven that the implantable device satisfies the HBM Class-1B ESD Standard. In addition, the evaluation of the worst-case charge density delivered to the tissue from each I/O pin verifies the patient safety of the device in the event of failure. Finally, the functionality and reliability of the complete device has been tested on-bench and further validated chronically in ongoing freely moving swine and monkey animal trials for more than one year to date. PMID:23853294

  16. Ultrathin, transferred layers of thermally grown silicon dioxide as biofluid barriers for biointegrated flexible electronic systems

    PubMed Central

    Fang, Hui; Yu, Ki Jun; Song, Enming; Farimani, Amir Barati; Chiang, Chia-Han; Jin, Xin; Xu, Dong; Du, Wenbo; Seo, Kyung Jin; Zhong, Yiding; Yang, Zijian; Won, Sang Min; Fang, Guanhua; Choi, Seo Woo; Chaudhuri, Santanu; Huang, Yonggang; Alam, Muhammad Ashraful; Viventi, Jonathan; Aluru, N. R.; Rogers, John A.

    2016-01-01

    Materials that can serve as long-lived barriers to biofluids are essential to the development of any type of chronic electronic implant. Devices such as cardiac pacemakers and cochlear implants use bulk metal or ceramic packages as hermetic enclosures for the electronics. Emerging classes of flexible, biointegrated electronic systems demand similar levels of isolation from biofluids but with thin, compliant films that can simultaneously serve as biointerfaces for sensing and/or actuation while in contact with the soft, curved, and moving surfaces of target organs. This paper introduces a solution to this materials challenge that combines (i) ultrathin, pristine layers of silicon dioxide (SiO2) thermally grown on device-grade silicon wafers, and (ii) processing schemes that allow integration of these materials onto flexible electronic platforms. Accelerated lifetime tests suggest robust barrier characteristics on timescales that approach 70 y, in layers that are sufficiently thin (less than 1 μm) to avoid significant compromises in mechanical flexibility or in electrical interface fidelity. Detailed studies of temperature- and thickness-dependent electrical and physical properties reveal the key characteristics. Molecular simulations highlight essential aspects of the chemistry that governs interactions between the SiO2 and surrounding water. Examples of use with passive and active components in high-performance flexible electronic devices suggest broad utility in advanced chronic implants. PMID:27791052

  17. Chronic multisite brain recordings from a totally implantable bidirectional neural interface: experience in 5 patients with Parkinson's disease.

    PubMed

    Swann, Nicole C; de Hemptinne, Coralie; Miocinovic, Svjetlana; Qasim, Salman; Ostrem, Jill L; Galifianakis, Nicholas B; Luciano, Marta San; Wang, Sarah S; Ziman, Nathan; Taylor, Robin; Starr, Philip A

    2018-02-01

    OBJECTIVE Dysfunction of distributed neural networks underlies many brain disorders. The development of neuromodulation therapies depends on a better understanding of these networks. Invasive human brain recordings have a favorable temporal and spatial resolution for the analysis of network phenomena but have generally been limited to acute intraoperative recording or short-term recording through temporarily externalized leads. Here, the authors describe their initial experience with an investigational, first-generation, totally implantable, bidirectional neural interface that allows both continuous therapeutic stimulation and recording of field potentials at multiple sites in a neural network. METHODS Under a physician-sponsored US Food and Drug Administration investigational device exemption, 5 patients with Parkinson's disease were implanted with the Activa PC+S system (Medtronic Inc.). The device was attached to a quadripolar lead placed in the subdural space over motor cortex, for electrocorticography potential recordings, and to a quadripolar lead in the subthalamic nucleus (STN), for both therapeutic stimulation and recording of local field potentials. Recordings from the brain of each patient were performed at multiple time points over a 1-year period. RESULTS There were no serious surgical complications or interruptions in deep brain stimulation therapy. Signals in both the cortex and the STN were relatively stable over time, despite a gradual increase in electrode impedance. Canonical movement-related changes in specific frequency bands in the motor cortex were identified in most but not all recordings. CONCLUSIONS The acquisition of chronic multisite field potentials in humans is feasible. The device performance characteristics described here may inform the design of the next generation of totally implantable neural interfaces. This research tool provides a platform for translating discoveries in brain network dynamics to improved neurostimulation paradigms. Clinical trial registration no.: NCT01934296 (clinicaltrials.gov).

  18. Bio-inspired hybrid microelectrodes: a hybrid solution to improve long-term performance of chronic intracortical implants

    PubMed Central

    De Faveri, Sara; Maggiolini, Emma; Miele, Ermanno; De Angelis, Francesco; Cesca, Fabrizia; Benfenati, Fabio; Fadiga, Luciano

    2014-01-01

    The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes – over time – compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses. PMID:24782757

  19. Patient satisfaction and aesthetic outcomes after ear reconstruction with a Branemark-type, bone-anchored, ear prosthesis: a 16 year review.

    PubMed

    Younis, Ibby; Gault, David; Sabbagh, Walid; Kang, Norbert V

    2010-10-01

    Reconstruction of the human ear with a bone-anchored prosthesis is a widely accepted alternative when autologous reconstruction is technically impossible or declined by the individual. However, there are relatively few data in the literature documenting patient satisfaction with this form of reconstruction. This study examines different aspects of patient satisfaction using an eighteen-point postal questionnaire to measure patient outcomes against a Likert rating scale. The questionnaire was sent to 33 patients who completed prosthetic ear reconstruction over a 16 year period at a specialist plastic surgery unit in the United Kingdom. Medical case notes for these cases were also reviewed. Twenty completed questionnaires were returned. The response rate was 61%. The majority of patients were satisfied with the aesthetics, ease of handling and comfort of the bone-anchored implant and prosthesis. However, the majority of patients was only moderately satisfied or was dissatisfied with this method of reconstruction. Specifically, 15 of the respondents reported skin problems around the abutments of the bone-anchored implant with 10 patients reporting ongoing skin complications. Granulation tissue was the most common skin problem (12 cases) followed by local infection (10 cases). Interestingly, despite the chronic skin problems, most patients indicated that they would undergo the same procedure again or would recommend it to others. Our survey shows that patients fitted with a Branemark-type bone-anchored implant for ear reconstruction are pleased with the aesthetic appearance but experience multiple, chronic, skin complications and other implant related problems. These affect their satisfaction with this method of reconstruction. Our findings may have significant implications for patients and surgeons considering this form of reconstruction and for the institutions making decisions about funding this treatment. Copyright 2009. Published by Elsevier Ltd.

  20. Nanoscale laminin coating modulates cortical scarring response around implanted silicon microelectrode arrays

    NASA Astrophysics Data System (ADS)

    He, Wei; McConnell, George C.; Bellamkonda, Ravi V.

    2006-12-01

    Neural electrodes could significantly enhance the quality of life for patients with sensory and/or motor deficits as well as improve our understanding of brain functions. However, long-term electrical connectivity between neural tissue and recording sites is compromised by the development of astroglial scar around the recording probes. In this study we investigate the effect of a nanoscale laminin (LN) coating on Si-based neural probes on chronic cortical tissue reaction in a rat model. Tissue reaction was evaluated after 1 day, 1 week, and 4 weeks post-implant for coated and uncoated probes using immunohistochemical techniques to evaluate activated microglia/macrophages (ED-1), astrocytes (GFAP) and neurons (NeuN). The coating did not have an observable effect on neuronal density or proximity to the electrode surface. However, the response of microglia/macrophages and astrocytes was altered by the coating. One day post-implant, we observed an ~60% increase in ED-1 expression near LN-coated probe sites compared with control uncoated probe sites. Four weeks post-implant, we observed an ~20% reduction in ED-1 expression along with an ~50% reduction in GFAP expression at coated relative to uncoated probe sites. These results suggest that LN has a stimulatory effect on early microglia activation, accelerating the phagocytic function of these cells. This hypothesis is further supported by the increased mRNA expression of several pro-inflammatory cytokines (TNF-α, IL-1 and IL-6) in cultured microglia on LN-bound Si substrates. LN immunostaining of coated probes immediately after insertion and retrieval demonstrates that the coating integrity is not compromised by the shear force during insertion. We speculate, based on these encouraging results, that LN coating of Si neural probes could potentially improve chronic neural recordings through dispersion of the astroglial scar.

Top