SU-E-J-234: Application of a Breathing Motion Model to ViewRay Cine MR Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
O’Connell, D. P.; Thomas, D. H.; Dou, T. H.
2015-06-15
Purpose: A respiratory motion model previously used to generate breathing-gated CT images was used with cine MR images. Accuracy and predictive ability of the in-plane models were evaluated. Methods: Sagittalplane cine MR images of a patient undergoing treatment on a ViewRay MRI/radiotherapy system were acquired before and during treatment. Images were acquired at 4 frames/second with 3.5 × 3.5 mm resolution and a slice thickness of 5 mm. The first cine frame was deformably registered to following frames. Superior/inferior component of the tumor centroid position was used as a breathing surrogate. Deformation vectors and surrogate measurements were used to determinemore » motion model parameters. Model error was evaluated and subsequent treatment cines were predicted from breathing surrogate data. A simulated CT cine was created by generating breathing-gated volumetric images at 0.25 second intervals along the measured breathing trace, selecting a sagittal slice and downsampling to the resolution of the MR cines. A motion model was built using the first half of the simulated cine data. Model accuracy and error in predicting the remaining frames of the cine were evaluated. Results: Mean difference between model predicted and deformably registered lung tissue positions for the 28 second preview MR cine acquired before treatment was 0.81 +/− 0.30 mm. The model was used to predict two minutes of the subsequent treatment cine with a mean accuracy of 1.59 +/− 0.63 mm. Conclusion: Inplane motion models were built using MR cine images and evaluated for accuracy and ability to predict future respiratory motion from breathing surrogate measurements. Examination of long term predictive ability is ongoing. The technique was applied to simulated CT cines for further validation, and the authors are currently investigating use of in-plane models to update pre-existing volumetric motion models used for generation of breathing-gated CT planning images.« less
Täng, Margareta Scharin; Redfors, Bjorn; Shao, Yangzhen; Omerovic, Elmir
2012-08-01
Regional myocardial deformation patterns are important in a variety of cardiac diseases, including stress-induced cardiomyopathy. Velocity-vector-based imaging is a speckle-tracking echocardiography (STE)-based algorithm that has been shown to allow in-depth cardiac phenotyping in humans. Regional posterior wall myocardial dysfunction occurs during severe isoprenaline stress in mice. We have previously shown that regional posterior wall end-systolic transmural strain decreases after severe isoprenaline toxicity in mice. We hypothesize that STE can detect and further quantify these perturbations. Twenty-three mice underwent echocardiographic examination using the VEVO2100 system. Regional transmural radial strain and strain rate were calculated in both parasternal short-axis and parasternal long-axis cine loops using the VisualSonics VEVO 2100 velocity vector imaging (VVI) STE algorithm. Eight C57BL/6 mice underwent baseline echocardiographic examination using the VisualSonics VEVO 770 system, which can acquire >1,000 frames/s cine loops. In a parasternal short-axis cine loop, the heart was divided into six segments, and regional fractional wall thickening (FWT) was assessed manually. The same protocols were also performed 90 minutes post 400 mg/kg intraperitoneally isoprenaline. Regional myocardial FWT is uniform at baseline but increases significantly in anterolateral segments, whereas it decreases significantly in posterior segments (P < 0.05). A similar pattern is seen using the VVI algorithm although the variance is larger, and differences are smaller and fail to reach significance. VVI is less sensitive in detecting regional perturbations in myocardial function than manual tracing, possibly due to the low frame rate in the cine loops used. © 2012, Wiley Periodicals, Inc.
Motion prediction in MRI-guided radiotherapy based on interleaved orthogonal cine-MRI
NASA Astrophysics Data System (ADS)
Seregni, M.; Paganelli, C.; Lee, D.; Greer, P. B.; Baroni, G.; Keall, P. J.; Riboldi, M.
2016-01-01
In-room cine-MRI guidance can provide non-invasive target localization during radiotherapy treatment. However, in order to cope with finite imaging frequency and system latencies between target localization and dose delivery, tumour motion prediction is required. This work proposes a framework for motion prediction dedicated to cine-MRI guidance, aiming at quantifying the geometric uncertainties introduced by this process for both tumour tracking and beam gating. The tumour position, identified through scale invariant features detected in cine-MRI slices, is estimated at high-frequency (25 Hz) using three independent predictors, one for each anatomical coordinate. Linear extrapolation, auto-regressive and support vector machine algorithms are compared against systems that use no prediction or surrogate-based motion estimation. Geometric uncertainties are reported as a function of image acquisition period and system latency. Average results show that the tracking error RMS can be decreased down to a [0.2; 1.2] mm range, for acquisition periods between 250 and 750 ms and system latencies between 50 and 300 ms. Except for the linear extrapolator, tracking and gating prediction errors were, on average, lower than those measured for surrogate-based motion estimation. This finding suggests that cine-MRI guidance, combined with appropriate prediction algorithms, could relevantly decrease geometric uncertainties in motion compensated treatments.
NASA Astrophysics Data System (ADS)
Kim, Soo Jeong; Lee, Dong Hyuk; Song, Inchang; Kim, Nam Gook; Park, Jae-Hyeung; Kim, JongHyo; Han, Man Chung; Min, Byong Goo
1998-07-01
Phase-contrast (PC) method of magnetic resonance imaging (MRI) has bee used for quantitative measurements of flow velocity and volume flow rate. It is a noninvasive technique which provides an accurate two-dimensional velocity image. Moreover, Phase Contrast Cine magnetic resonance imaging combines the flow dependent contrast of PC-MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. However, the accuracy of the data acquired from the single through-plane velocity encoding can be reduced by the effect of flow direction, because in many practical cases flow directions are not uniform throughout the whole region of interest. In this study, we present dynamic three-dimensional velocity vector mapping method using PC-MRI which can visualize the complex flow pattern through 3D volume rendered images displayed dynamically. The direction of velocity mapping can be selected along any three orthogonal axes. By vector summation, the three maps can be combined to form a velocity vector map that determines the velocity regardless of the flow direction. At the same time, Cine method is used to observe the dynamic change of flow. We performed a phantom study to evaluate the accuracy of the suggested PC-MRI in continuous and pulsatile flow measurement. Pulsatile flow wave form is generated by the ventricular assistant device (VAD), HEMO-PULSA (Biomedlab, Seoul, Korea). We varied flow velocity, pulsatile flow wave form, and pulsing rate. The PC-MRI-derived velocities were compared with Doppler-derived results. The velocities of the two measurements showed a significant linear correlation. Dynamic three-dimensional velocity vector mapping was carried out for two cases. First, we applied to the flow analysis around the artificial heart valve in a flat phantom. We could observe the flow pattern around the valve through the 3-dimensional cine image. Next, it is applied to the complex flow inside the polymer sac that is used as ventricle in totally implantable artificial heart (TAH). As a result we could observe the flow pattern around the valves of the sac, though complex flow can not be detected correctly in the conventional phase contrast method. In addition, we could calculate the cardiac output from TAH sac by quantitative measurement of the volume of flow across the outlet valve.
A four-dimensional motion field atlas of the tongue from tagged and cine magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Xing, Fangxu; Prince, Jerry L.; Stone, Maureen; Wedeen, Van J.; El Fakhri, Georges; Woo, Jonghye
2017-02-01
Representation of human tongue motion using three-dimensional vector fields over time can be used to better understand tongue function during speech, swallowing, and other lingual behaviors. To characterize the inter-subject variability of the tongue's shape and motion of a population carrying out one of these functions it is desirable to build a statistical model of the four-dimensional (4D) tongue. In this paper, we propose a method to construct a spatio-temporal atlas of tongue motion using magnetic resonance (MR) images acquired from fourteen healthy human subjects. First, cine MR images revealing the anatomical features of the tongue are used to construct a 4D intensity image atlas. Second, tagged MR images acquired to capture internal motion are used to compute a dense motion field at each time frame using a phase-based motion tracking method. Third, motion fields from each subject are pulled back to the cine atlas space using the deformation fields computed during the cine atlas construction. Finally, a spatio-temporal motion field atlas is created to show a sequence of mean motion fields and their inter-subject variation. The quality of the atlas was evaluated by deforming cine images in the atlas space. Comparison between deformed and original cine images showed high correspondence. The proposed method provides a quantitative representation to observe the commonality and variability of the tongue motion field for the first time, and shows potential in evaluation of common properties such as strains and other tensors based on motion fields.
A Four-dimensional Motion Field Atlas of the Tongue from Tagged and Cine Magnetic Resonance Imaging.
Xing, Fangxu; Prince, Jerry L; Stone, Maureen; Wedeen, Van J; Fakhri, Georges El; Woo, Jonghye
2017-01-01
Representation of human tongue motion using three-dimensional vector fields over time can be used to better understand tongue function during speech, swallowing, and other lingual behaviors. To characterize the inter-subject variability of the tongue's shape and motion of a population carrying out one of these functions it is desirable to build a statistical model of the four-dimensional (4D) tongue. In this paper, we propose a method to construct a spatio-temporal atlas of tongue motion using magnetic resonance (MR) images acquired from fourteen healthy human subjects. First, cine MR images revealing the anatomical features of the tongue are used to construct a 4D intensity image atlas. Second, tagged MR images acquired to capture internal motion are used to compute a dense motion field at each time frame using a phase-based motion tracking method. Third, motion fields from each subject are pulled back to the cine atlas space using the deformation fields computed during the cine atlas construction. Finally, a spatio-temporal motion field atlas is created to show a sequence of mean motion fields and their inter-subject variation. The quality of the atlas was evaluated by deforming cine images in the atlas space. Comparison between deformed and original cine images showed high correspondence. The proposed method provides a quantitative representation to observe the commonality and variability of the tongue motion field for the first time, and shows potential in evaluation of common properties such as strains and other tensors based on motion fields.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, J; Jung, J; Yeo, I
2015-06-15
Purpose: To develop and to test a method to generate a new 4D CT images of the treatment day from the old 4D CT and the portal images of the day when the motion extent exceeded from that represented by plan CTs. Methods: A motion vector of a moving tumor in a patient may be extended to reconstruct the tumor position when the motion extent exceeded from that represented by plan CTs. To test this, 1. a phantom that consists of a polystyrene cylinder (tumor) embedded in cork (lung) was placed on a moving platform with 4 sec/cycle and amplitudesmore » of 1 cm and 2 cm, and was 4D-scanned. 2. A 6MV photon beam was irradiated on the moving phantoms and cineEPID images were obtained. 3. A motion vector of the tumor was acquired from 4D CT images of the phantom with 1 cm amplitude. 4. From cine EPID images of the phantom with the 2 cm amplitude, various motion extents (0.3 cm, 0.5 cm, etc) were acquired and programmed into the motion vector, producing CT images at each position. 5. The reconstructed CT images were then compared with pre-acquired “reference” 4D CT images at each position (i.e. phase). Results: The CT image was reconstructed and compared with the reference image, showing a slight mismatch in the transition direction limited by voxel size (slice thickness) in CT image. Due to the rigid nature of the phantom studied, the modeling the displacement of the center of object was sufficient. When deformable tumors are to be modeled, more complex scheme is necessary, which utilize cine EPID and 4D CT images. Conclusion: The new idea of CT image reconstruction was demonstrated. Deformable tumor movements need to be considered in the future.« less
NASA Astrophysics Data System (ADS)
O'Donnell, Thomas P.; Xu, Ning; Setser, Randolph M.; White, Richard D.
2003-05-01
Post myocardial infarction, the identification and assessment of non-viable (necrotic) tissues is necessary for effective development of intervention strategies and treatment plans. Delayed Enhancement Magnetic Resonance (DEMR) imaging is a technique whereby non-viable cardiac tissue appears with increased signal intensity. Radiologists typically acquire these images in conjunction with other functional modalities (e.g., MR Cine), and use domain knowledge and experience to isolate the non-viable tissues. In this paper, we present a technique for automatically segmenting these tissues given the delineation of myocardial borders in the DEMR and in the End-systolic and End-diastolic MR Cine images. Briefly, we obtain a set of segmentations furnished by an expert and employ an artificial intelligence technique, Support Vector Machines (SVMs), to "learn" the segmentations based on features culled from the images. Using those features we then allow the SVM to predict the segmentations the expert would provide on previously unseen images.
NASA Astrophysics Data System (ADS)
Coghlan, Leslie; Singleton, H. R.; Dell'Italia, L. J.; Linderholm, C. E.; Pohost, G. M.
1995-05-01
We have developed a method for measuring the detailed in vivo three dimensional geometry of the left and right ventricles using cine-magnetic resonance imaging. From data in the form of digitized short axis outlines, the normal vectors, principal curvatures and directions, and wall thickness were computed. The method was evaluated on simulated ellipsoids and on human MRI data. Measurements of normal vectors and of wall thickness were very accurate in simulated data and appeared appropriate in patient data. On simulated data, measurements of the principal curvature k1 (corresponding approximately to the short axis direction of the left ventricle) and of principal directions were quite accurate, but measurements of the other principal curvature (k2) were less accurate. The reasons behind this are considered. We expect improvements in the accuracy with thinner slices and improved representation of the surface data. Gradient echo images were acquired from 8 dogs with a 1.5T system (Philips Gyroscan) at baseline and four months after closed chest experimentally produced mitral regurgitation (MR). The product (k1 + k2) X wall thickness averaged over all slices at end-diastole was significantly lower after surgery (n equals 8, p < 0.005). These geometry changes were consistent with the expected increase in wall stress after MR.
Evaluation of potential internal target volume of liver tumors using cine-MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akino, Yuichi, E-mail: akino@radonc.med.osaka-u.ac.jp; Oh, Ryoong-Jin; Masai, Norihisa
2014-11-01
Purpose: Four-dimensional computed tomography (4DCT) is widely used for evaluating moving tumors, including lung and liver cancers. For patients with unstable respiration, however, the 4DCT may not visualize tumor motion properly. High-speed magnetic resonance imaging (MRI) sequences (cine-MRI) permit direct visualization of respiratory motion of liver tumors without considering radiation dose exposure to patients. Here, the authors demonstrated a technique for evaluating internal target volume (ITV) with consideration of respiratory variation using cine-MRI. Methods: The authors retrospectively evaluated six patients who received stereotactic body radiotherapy (SBRT) to hepatocellular carcinoma. Before acquiring planning CT, sagittal and coronal cine-MRI images were acquiredmore » for 30 s with a frame rate of 2 frames/s. The patient immobilization was conducted under the same condition as SBRT. Planning CT images were then acquired within 15 min from cine-MRI image acquisitions, followed by a 4DCT scan. To calculate tumor motion, the motion vectors between two continuous frames of cine-MRI images were calculated for each frame using the pyramidal Lucas–Kanade method. The target contour was delineated on one frame, and each vertex of the contour was shifted and copied onto the following frame using neighboring motion vectors. 3D trajectory data were generated with the centroid of the contours on sagittal and coronal images. To evaluate the accuracy of the tracking method, the motion of clearly visible blood vessel was analyzed with the motion tracking and manual detection techniques. The target volume delineated on the 50% (end-exhale) phase of 4DCT was translated with the trajectory data, and the distribution of the occupancy probability of target volume was calculated as potential ITV (ITV {sub Potential}). The concordance between ITV {sub Potential} and ITV estimated with 4DCT (ITV {sub 4DCT}) was evaluated using the Dice’s similarity coefficient (DSC). Results: The distance between blood vessel positions determined with motion tracking and manual detection was analyzed. The mean and SD of the distance were less than 0.80 and 0.52 mm, respectively. The maximum ranges of tumor motion on cine-MRI were 2.4 ± 1.4 mm (range, 1.0–5.0 mm), 4.4 ± 3.3 mm (range, 0.8–9.4 mm), and 14.7 ± 5.9 mm (range, 7.4–23.4 mm) in lateral, anterior–posterior, and superior–inferior directions, respectively. The ranges in the superior–inferior direction were larger than those estimated with 4DCT images for all patients. The volume of ITV {sub Potential} was 160.3% ± 13.5% (range, 142.0%–179.2%) of the ITV {sub 4DCT}. The maximum DSC values were observed when the cutoff value of 24.7% ± 4.0% (range, 20%–29%) was applied. Conclusions: The authors demonstrated a novel method of calculating 3D motion and ITV {sub Potential} of liver cancer using orthogonal cine-MRI. Their method achieved accurate calculation of the respiratory motion of moving structures. Individual evaluation of the ITV {sub Potential} will aid in improving respiration management and treatment planning.« less
Visualization of flow by vector analysis of multidirectional cine MR velocity mapping.
Mohiaddin, R H; Yang, G Z; Kilner, P J
1994-01-01
We describe a noninvasive method for visualization of flow and demonstrate its application in a flow phantom and in the great vessels of healthy volunteers and patients with aortic and pulmonary arterial disease. The technique uses multidirectional MR velocity mapping acquired in selected planes. Maps of orthogonal velocity components were then processed into a graphic form immediately recognizable as flow. Cine MR velocity maps of orthogonal velocity components in selected planes were acquired in a flow phantom, 10 healthy volunteers, and 13 patients with dilated great vessels. Velocities were presented by multiple computer-generated streaks whose orientation, length, and movement corresponded to velocity vectors in the chosen plane. The velocity vector maps allowed visualization of complex patterns of primary and secondary flow in the thoracic aorta and pulmonary arteries. The technique revealed coherent, helical forward blood movements in the normal thoracic aorta during midsystole and a reverse flow during early diastole. Abnormal flow patterns with secondary vortices were seen in patients with dilated arteries. The potential of MR velocity vector mapping for in vitro and in vivo visualization of flow patterns is demonstrated. Although this study was limited to two-directional flow in a single anatomical plane, the method provides information that might advance our understanding of the human vascular system in health and disease. Further developments to reduce the acquisition time and the handling and presenting of three-directional velocity data are required to enhance the capability of this method.
Mishra, Pankaj; Li, Ruijiang; Mak, Raymond H.; Rottmann, Joerg; Bryant, Jonathan H.; Williams, Christopher L.; Berbeco, Ross I.; Lewis, John H.
2014-01-01
Purpose: In this work the authors develop and investigate the feasibility of a method to estimate time-varying volumetric images from individual MV cine electronic portal image device (EPID) images. Methods: The authors adopt a two-step approach to time-varying volumetric image estimation from a single cine EPID image. In the first step, a patient-specific motion model is constructed from 4DCT. In the second step, parameters in the motion model are tuned according to the information in the EPID image. The patient-specific motion model is based on a compact representation of lung motion represented in displacement vector fields (DVFs). DVFs are calculated through deformable image registration (DIR) of a reference 4DCT phase image (typically peak-exhale) to a set of 4DCT images corresponding to different phases of a breathing cycle. The salient characteristics in the DVFs are captured in a compact representation through principal component analysis (PCA). PCA decouples the spatial and temporal components of the DVFs. Spatial information is represented in eigenvectors and the temporal information is represented by eigen-coefficients. To generate a new volumetric image, the eigen-coefficients are updated via cost function optimization based on digitally reconstructed radiographs and projection images. The updated eigen-coefficients are then multiplied with the eigenvectors to obtain updated DVFs that, in turn, give the volumetric image corresponding to the cine EPID image. Results: The algorithm was tested on (1) Eight digital eXtended CArdiac-Torso phantom datasets based on different irregular patient breathing patterns and (2) patient cine EPID images acquired during SBRT treatments. The root-mean-squared tumor localization error is (0.73 ± 0.63 mm) for the XCAT data and (0.90 ± 0.65 mm) for the patient data. Conclusions: The authors introduced a novel method of estimating volumetric time-varying images from single cine EPID images and a PCA-based lung motion model. This is the first method to estimate volumetric time-varying images from single MV cine EPID images, and has the potential to provide volumetric information with no additional imaging dose to the patient. PMID:25086523
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mishra, Pankaj, E-mail: pankaj.mishra@varian.com; Mak, Raymond H.; Rottmann, Joerg
2014-08-15
Purpose: In this work the authors develop and investigate the feasibility of a method to estimate time-varying volumetric images from individual MV cine electronic portal image device (EPID) images. Methods: The authors adopt a two-step approach to time-varying volumetric image estimation from a single cine EPID image. In the first step, a patient-specific motion model is constructed from 4DCT. In the second step, parameters in the motion model are tuned according to the information in the EPID image. The patient-specific motion model is based on a compact representation of lung motion represented in displacement vector fields (DVFs). DVFs are calculatedmore » through deformable image registration (DIR) of a reference 4DCT phase image (typically peak-exhale) to a set of 4DCT images corresponding to different phases of a breathing cycle. The salient characteristics in the DVFs are captured in a compact representation through principal component analysis (PCA). PCA decouples the spatial and temporal components of the DVFs. Spatial information is represented in eigenvectors and the temporal information is represented by eigen-coefficients. To generate a new volumetric image, the eigen-coefficients are updated via cost function optimization based on digitally reconstructed radiographs and projection images. The updated eigen-coefficients are then multiplied with the eigenvectors to obtain updated DVFs that, in turn, give the volumetric image corresponding to the cine EPID image. Results: The algorithm was tested on (1) Eight digital eXtended CArdiac-Torso phantom datasets based on different irregular patient breathing patterns and (2) patient cine EPID images acquired during SBRT treatments. The root-mean-squared tumor localization error is (0.73 ± 0.63 mm) for the XCAT data and (0.90 ± 0.65 mm) for the patient data. Conclusions: The authors introduced a novel method of estimating volumetric time-varying images from single cine EPID images and a PCA-based lung motion model. This is the first method to estimate volumetric time-varying images from single MV cine EPID images, and has the potential to provide volumetric information with no additional imaging dose to the patient.« less
Machine learning for the automatic localisation of foetal body parts in cine-MRI scans
NASA Astrophysics Data System (ADS)
Bowles, Christopher; Nowlan, Niamh C.; Hayat, Tayyib T. A.; Malamateniou, Christina; Rutherford, Mary; Hajnal, Joseph V.; Rueckert, Daniel; Kainz, Bernhard
2015-03-01
Being able to automate the location of individual foetal body parts has the potential to dramatically reduce the work required to analyse time resolved foetal Magnetic Resonance Imaging (cine-MRI) scans, for example, for use in the automatic evaluation of the foetal development. Currently, manual preprocessing of every scan is required to locate body parts before analysis can be performed, leading to a significant time overhead. With the volume of scans becoming available set to increase as cine-MRI scans become more prevalent in clinical practice, this stage of manual preprocessing is a bottleneck, limiting the data available for further analysis. Any tools which can automate this process will therefore save many hours of research time and increase the rate of new discoveries in what is a key area in understanding early human development. Here we present a series of techniques which can be applied to foetal cine-MRI scans in order to first locate and then differentiate between individual body parts. A novel approach to maternal movement suppression and segmentation using Fourier transforms is put forward as a preprocessing step, allowing for easy extraction of short movements of individual foetal body parts via the clustering of optical flow vector fields. These body part movements are compared to a labelled database and probabilistically classified before being spatially and temporally combined to give a final estimate for the location of each body part.
NASA Astrophysics Data System (ADS)
Lee, Taek-Soo; Frey, Eric C.; Tsui, Benjamin M. W.
2015-04-01
This paper presents two 4D mathematical observer models for the detection of motion defects in 4D gated medical images. Their performance was compared with results from human observers in detecting a regional motion abnormality in simulated 4D gated myocardial perfusion (MP) SPECT images. The first 4D mathematical observer model extends the conventional channelized Hotelling observer (CHO) based on a set of 2D spatial channels and the second is a proposed model that uses a set of 4D space-time channels. Simulated projection data were generated using the 4D NURBS-based cardiac-torso (NCAT) phantom with 16 gates/cardiac cycle. The activity distribution modelled uptake of 99mTc MIBI with normal perfusion and a regional wall motion defect. An analytical projector was used in the simulation and the filtered backprojection (FBP) algorithm was used in image reconstruction followed by spatial and temporal low-pass filtering with various cut-off frequencies. Then, we extracted 2D image slices from each time frame and reorganized them into a set of cine images. For the first model, we applied 2D spatial channels to the cine images and generated a set of feature vectors that were stacked for the images from different slices of the heart. The process was repeated for each of the 1,024 noise realizations, and CHO and receiver operating characteristics (ROC) analysis methodologies were applied to the ensemble of the feature vectors to compute areas under the ROC curves (AUCs). For the second model, a set of 4D space-time channels was developed and applied to the sets of cine images to produce space-time feature vectors to which the CHO methodology was applied. The AUC values of the second model showed better agreement (Spearman’s rank correlation (SRC) coefficient = 0.8) to human observer results than those from the first model (SRC coefficient = 0.4). The agreement with human observers indicates the proposed 4D mathematical observer model provides a good predictor of the performance of human observers in detecting regional motion defects in 4D gated MP SPECT images. The result supports the use of the observer model in the optimization and evaluation of 4D image reconstruction and compensation methods for improving the detection of motion abnormalities in 4D gated MP SPECT images.
NASA Astrophysics Data System (ADS)
Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.
2017-03-01
Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.
Causes of cine image quality deterioration in cardiac catheterization laboratories.
Levin, D C; Dunham, L R; Stueve, R
1983-10-01
Deterioration of cineangiographic image quality can result from malfunctions or technical errors at a number of points along the cine imaging chain: generator and automatic brightness control, x-ray tube, x-ray beam geometry, image intensifier, optics, cine camera, cine film, film processing, and cine projector. Such malfunctions or errors can result in loss of image contrast, loss of spatial resolution, improper control of film optical density (brightness), or some combination thereof. While the electronic and photographic technology involved is complex, physicians who perform cardiac catheterization should be conversant with the problems and what can be done to solve them. Catheterization laboratory personnel have control over a number of factors that directly affect image quality, including radiation dose rate per cine frame, kilovoltage or pulse width (depending on type of automatic brightness control), cine run time, selection of small or large focal spot, proper object-intensifier distance and beam collimation, aperture of the cine camera lens, selection of cine film, processing temperature, processing immersion time, and selection of developer.
Moghari, Mehdi H; Barthur, Ashita; Amaral, Maria E; Geva, Tal; Powell, Andrew J
2018-07-01
To develop and validate a new prospective respiratory motion compensation algorithm for free-breathing whole-heart 3D cine steady-state free precession (SSFP) imaging. In a 3D cine SSFP sequence, 4 excitations per cardiac cycle are re-purposed to prospectively track heart position. Specifically, their 1D image is reconstructed and routed into the scanner's standard diaphragmatic navigator processing system. If all 4 signals are in end-expiration, cine image data from the entire cardiac cycle is accepted for image reconstruction. Prospective validation was carried out in patients (N = 17) by comparing in each a conventional breath-hold 2D cine ventricular short-axis stack and a free-breathing whole-heart 3D cine data set. All 3D cine SSFP acquisitions were successful and the mean scan time was 5.9 ± 2.7 min. Left and right ventricular end-diastolic, end-systolic, and stroke volumes by 3D cine SSFP were all larger than those from 2D cine SSFP. This bias was < 6% except for right ventricular end-systolic volume that was 12%. The 3D cine images had a lower ventricular blood-to-myocardium contrast ratio, contrast-to-noise ratio, mass, and subjective quality score. The novel prospective respiratory motion compensation method for 3D cine SSFP imaging was robust and efficient and yielded slightly larger ventricular volumes and lower mass compared to breath-hold 2D cine imaging. Magn Reson Med 80:181-189, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun
2015-04-01
Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; P<.001). Mean fluoroscopy times were higher in the cine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; P<.01). Mean contrast use was higher in the cine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; P<.001). Mean value of Crombach's alpha was not statistically different between visual estimates of three operators between cine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.
Edelman, Robert R; Serhal, Ali; Pursnani, Amit; Pang, Jianing; Koktzoglou, Ioannis
2018-02-19
Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow quantification, while enabling an efficient, visually-appealing, semi-projective display of blood flow patterns throughout the course of an artery and its branches.
Left ventricular strain and its pattern estimated from cine CMR and validation with DENSE
NASA Astrophysics Data System (ADS)
Gao, Hao; Allan, Andrew; McComb, Christie; Luo, Xiaoyu; Berry, Colin
2014-07-01
Measurement of local strain provides insight into the biomechanical significance of viable myocardium. We attempted to estimate myocardial strain from cine cardiovascular magnetic resonance (CMR) images by using a b-spline deformable image registration method. Three healthy volunteers and 41 patients with either recent or chronic myocardial infarction (MI) were studied at 1.5 Tesla with both cine and DENSE CMR. Regional circumferential and radial left ventricular strains were estimated from cine and DENSE acquisitions. In all healthy volunteers, there was no difference for peak circumferential strain (- 0.18 ± 0.04 versus - 0.18 ± 0.03, p = 0.76) between cine and DENSE CMR, however peak radial strain was overestimated from cine (0.84 ± 0.37 versus 0.49 ± 0.2, p < 0.01). In the patient study, the peak strain patterns predicted by cine were similar to the patterns from DENSE, including the strain evolution related to recovery time and strain patterns related to MI scar extent. Furthermore, cine-derived strain disclosed different strain patterns in MI and non-MI regions, and regions with transmural and non-transmural MI as DENSE. Although there were large variations with radial strain measurements from cine CMR images, useful circumferential strain information can be obtained from routine clinical CMR imaging. Cine strain analysis has potential to improve the diagnostic yield from routine CMR imaging in clinical practice.
Ciet, Pierluigi; Wielopolski, Piotr; Manniesing, Rashindra; Lever, Sandra; de Bruijne, Marleen; Morana, Giovanni; Muzzio, Pier Carlo; Lequin, Maarten H; Tiddens, Harm A W M
2014-01-01
Tracheobronchomalacia (TBM) is defined as an excessive collapse of the intrathoracic trachea. Bronchoscopy is the gold standard for diagnosing TBM; however it has major disadvantages, such as general anaesthesia. Cine computed tomography (CT) is a noninvasive alternative used to diagnose TBM, but its use in children is restricted by ionising radiation. Our aim was to evaluate the feasibility of spirometer-controlled cine magnetic resonance imaging (MRI) as an alternative to cine-CT in a retrospective study. 12 children with a mean age (range) of 12 years (7-17 years), suspected of having TBM, underwent cine-MRI. Static scans were acquired at end-inspiration and expiration covering the thorax using a three-dimensional spoiled gradient echo sequence. Three-dimensional dynamic scans were performed covering only the central airways. TBM was defined as a decrease of the trachea or bronchi diameter >50% at end-expiration in the static and dynamic scans. The success rate of the cine-MRI protocol was 92%. Cine-MRI was compared with bronchoscopy or chest CT in seven subjects. TBM was diagnosed by cine-MRI in seven (58%) out of 12 children and was confirmed by bronchoscopy or CT. In four patients, cine-MRI demonstrated tracheal narrowing that was not present in the static scans. Spirometer controlled cine-MRI is a promising technique to assess TBM in children and has the potential to replace bronchoscopy.
Thattaliyath, Bijoy D; Forsha, Daniel E; Stewart, Chad; Barker, Piers C A; Campbell, Michael J
2015-01-01
The aim of the study was to determine right and left ventricle deformation parameters in patients with transposition of the great arteries who had undergone atrial or arterial switch procedures. Patients with transposition are born with a systemic right ventricle. Historically, the atrial switch operation, in which the right ventricle remains the systemic ventricle, was performed. These patients have increased rates of morbidity and mortality. We used cardiac MRI with Velocity Vector Imaging analysis to characterize and compare ventricular myocardial deformation in patients who had an atrial switch or arterial switch operation. Patients with a history of these procedures, who had a clinically ordered cardiac MRI were included in the study. Consecutive 20 patients (75% male, 28.7 ± 1.8 years) who underwent atrial switch operation and 20 patients (60% male, 17.7 ± 1.9 years) who underwent arterial switch operation were included in the study. Four chamber and short-axis cine images were used to determine longitudinal and circumferential strain and strain rate using Vector Velocity Imaging software. Compared with the arterial switch group, the atrial switch group had decreased right ventricular ejection fraction and increased end-diastolic and end-systolic volumes, and no difference in left ventricular ejection fraction and volumes. The atrial switch group had decreased longitudinal and circumferential strain and strain rate. When compared with normal controls multiple strain parameters in the atrial switch group were reduced. Myocardial deformation analysis of transposition patients reveals a reduction of right ventricular function and decreased longitudinal and circumferential strain parameters in patients with an atrial switch operation compared with those with arterial switch operation. A better understanding of the mechanisms of right ventricle failure in transposition of great arteries may lead to improved therapies and adaptation. © 2015 Wiley Periodicals, Inc.
21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...
21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...
21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...
21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...
21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...
[The diagnostic value of cine-MR imaging in diseases of great vessels].
Sasaki, S; Yoshida, H; Matsui, Y; Sakuma, M; Yasuda, K; Tanabe, T; Chouji, H
1990-02-01
The diagnostic value of cine magnetic resonance imaging (cine-MRI) was evaluated in 10 patients with disease of great vessels. The parameters necessary to decide the appropriate treatment, such as presence and extension of intimal flap, DeBakey type classification, identification of the entry, differentiation between true and false lumen, and between thrombosis and slow flow were demonstrated in all patients with dissecting aortic aneurysm. However, abdominal aortic branches could not be demonstrated enough by cine-MRI, therefore conventional AOG was necessary to choose the operative procedure in these cases. In patients with thoracic aortic aneurysm (TAA), cine-MRI was valuable in demonstrating both blood flow and thrombus in the lumen of aneurysm, and AOG was thought to be unnecessary in most cases. Cine-MRI is a promising new technique for the evaluation of diseases of great vessels.
Exposure Range For Cine Radiographic Procedures
NASA Astrophysics Data System (ADS)
Moore, Robert J.
1980-08-01
Based on the author's experience, state-of-the-art cine radiographic equipment of the type used in modern cardiovascular laboratories for selective coronary arteriography must perform at well-defined levels to produce cine images with acceptable quantum mottle, contrast, and detail, as judged by consensus of across section of American cardiologists/radiologists experienced in viewing such images. Accordingly, a "standard" undertable state-of-the-art cine radiographic imaging system is postulated to answer the question of what patient exposure range is necessary to obtain cine images of acceptable quality. It is shown that such a standard system would be expected to produce a 'tabletop exposure of about 25 milliRoentgens per frame for the "standard" adult patient, plus-or-minus 33% for accept-able variation of system parameters. This means that for cine radiography at 60 frames per second (30 frames per second) the exposure rate range based on this model is 60 to 120 Roentgens per minute (30 to 60 Roentgens per minute). The author contends that studies at exposure levels below these will yield cine images of questionable diagnostic value; studies at exposure levels above these may yield cine images of excellent visual quality but having little additional diagnostic value, at the expense of added patient/personnel radiation exposure and added x-ray tube heat loading.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueda, Yoshihiro, E-mail: ueda-yo@mc.pref.osaka.jp; Miyazaki, Masayoshi; Nishiyama, Kinji
2012-07-01
Purpose: To evaluate setup error and interfractional changes in tumor motion magnitude using an electric portal imaging device in cine mode (EPID cine) during the course of stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC) and to calculate margins to compensate for these variations. Materials and Methods: Subjects were 28 patients with Stage I NSCLC who underwent SBRT. Respiratory-correlated four-dimensional computed tomography (4D-CT) at simulation was binned into 10 respiratory phases, which provided average intensity projection CT data sets (AIP). On 4D-CT, peak-to-peak motion of the tumor (M-4DCT) in the craniocaudal direction was assessed and the tumor centermore » (mean tumor position [MTP]) of the AIP (MTP-4DCT) was determined. At treatment, the tumor on cone beam CT was registered to that on AIP for patient setup. During three sessions of irradiation, peak-to-peak motion of the tumor (M-cine) and the mean tumor position (MTP-cine) were obtained using EPID cine and in-house software. Based on changes in tumor motion magnitude ( Increment M) and patient setup error ( Increment MTP), defined as differences between M-4DCT and M-cine and between MTP-4DCT and MTP-cine, a margin to compensate for these variations was calculated with Stroom's formula. Results: The means ({+-}standard deviation: SD) of M-4DCT and M-cine were 3.1 ({+-}3.4) and 4.0 ({+-}3.6) mm, respectively. The means ({+-}SD) of Increment M and Increment MTP were 0.9 ({+-}1.3) and 0.2 ({+-}2.4) mm, respectively. Internal target volume-planning target volume (ITV-PTV) margins to compensate for Increment M, Increment MTP, and both combined were 3.7, 5.2, and 6.4 mm, respectively. Conclusion: EPID cine is a useful modality for assessing interfractional variations of tumor motion. The ITV-PTV margins to compensate for these variations can be calculated.« less
SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bawazeer, O; Deb, P; Sarasanandarajah, S
2016-06-15
Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest ofmore » the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.« less
TH-A-BRF-04: Intra-Fraction Motion Characterization for Early Stage Rectal Cancer Using Cine-MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kleijnen, J; Asselen, B; Burbach, M
2014-06-15
Purpose: To investigate the intra-fraction motion in patients with early stage rectal cancer using cine-MRI. Methods: Sixteen patient diagnosed with early stage rectal cancer underwent 1.5 T MR imaging prior to each treatment fraction of their short course radiotherapy (n=76). During each scan session, three 2D sagittal cine-MRIs were performed: at the beginning (Start), after 9:30 minutes (Mid), and after 18 minutes (End). Each cine-MRI has a duration of one minute at 2Hz temporal resolution, resulting in a total of 3:48 hours of cine-MRI. Additionally, standard T2-weighted (T2w) imaging was performed. Clinical target volume (CTV) an tumor (GTV) were delineatedmore » on the T2w scan and transferred to the first time-point of each cine-MRI scan. Within each cine-MRI, the first frame was registered to the remaining frames of the scan, using a non-rigid B-spline registration. To investigate potential drifts, a similar registration was performed between the first frame of the Start and End scans.To evaluate the motion, the distances by which the edge pixels of the delineations move in anterior-posterior (AP) and cranial-caudal (CC) direction, were determined using the deformation field of the registrations. The distance which incorporated 95% of these edge pixels (dist95%) was determined within each cine-MRI, and between Start- End scans, respectively. Results: Within a cine-MRI, we observed an average dist95% for the CTV of 1.3mm/1.5mm (SD=0.7mm/0.6mm) and for the GTV of 1.2mm/1.5mm (SD=0.8mm/0.9mm), in respectively AP/CC. For the CTV motion between the Start and End scan, an average dist95% of 5.5mm/5.3mm (SD=3.1mm/2.5mm) was found, in respectively AP/CC. For the GTV motion, an average dist95% of 3.6mm/3.9mm (SD=2.2mm/2.5mm) was found in AP/CC, respectively. Conclusion: Although intra-fraction motion within a one minute cine-MRI is limited, substantial intra-fraction motion was observed within the 18 minute time period between the Start and End cine-MRI.« less
Automatic segmentation of left ventricle in cardiac cine MRI images based on deep learning
NASA Astrophysics Data System (ADS)
Zhou, Tian; Icke, Ilknur; Dogdas, Belma; Parimal, Sarayu; Sampath, Smita; Forbes, Joseph; Bagchi, Ansuman; Chin, Chih-Liang; Chen, Antong
2017-02-01
In developing treatment of cardiovascular diseases, short axis cine MRI has been used as a standard technique for understanding the global structural and functional characteristics of the heart, e.g. ventricle dimensions, stroke volume and ejection fraction. To conduct an accurate assessment, heart structures need to be segmented from the cine MRI images with high precision, which could be a laborious task when performed manually. Herein a fully automatic framework is proposed for the segmentation of the left ventricle from the slices of short axis cine MRI scans of porcine subjects using a deep learning approach. For training the deep learning models, which generally requires a large set of data, a public database of human cine MRI scans is used. Experiments on the 3150 cine slices of 7 porcine subjects have shown that when comparing the automatic and manual segmentations the mean slice-wise Dice coefficient is about 0.930, the point-to-curve error is 1.07 mm, and the mean slice-wise Hausdorff distance is around 3.70 mm, which demonstrates the accuracy and robustness of the proposed inter-species translational approach.
Subspace aware recovery of low rank and jointly sparse signals
Biswas, Sampurna; Dasgupta, Soura; Mudumbai, Raghuraman; Jacob, Mathews
2017-01-01
We consider the recovery of a matrix X, which is simultaneously low rank and joint sparse, from few measurements of its columns using a two-step algorithm. Each column of X is measured using a combination of two measurement matrices; one which is the same for every column, while the the second measurement matrix varies from column to column. The recovery proceeds by first estimating the row subspace vectors from the measurements corresponding to the common matrix. The estimated row subspace vectors are then used to recover X from all the measurements using a convex program of joint sparsity minimization. Our main contribution is to provide sufficient conditions on the measurement matrices that guarantee the recovery of such a matrix using the above two-step algorithm. The results demonstrate quite significant savings in number of measurements when compared to the standard multiple measurement vector (MMV) scheme, which assumes same time invariant measurement pattern for all the time frames. We illustrate the impact of the sampling pattern on reconstruction quality using breath held cardiac cine MRI and cardiac perfusion MRI data, while the utility of the algorithm to accelerate the acquisition is demonstrated on MR parameter mapping. PMID:28630889
Accelerated self-gated UTE MRI of the murine heart
NASA Astrophysics Data System (ADS)
Motaal, Abdallah G.; Noorman, Nils; De Graaf, Wolter L.; Florack, Luc J.; Nicolay, Klaas; Strijkers, Gustav J.
2014-03-01
We introduce a new protocol to obtain radial Ultra-Short TE (UTE) MRI Cine of the beating mouse heart within reasonable measurement time. The method is based on a self-gated UTE with golden angle radial acquisition and compressed sensing reconstruction. The stochastic nature of the retrospective triggering acquisition scheme produces an under-sampled and random kt-space filling that allows for compressed sensing reconstruction, hence reducing scan time. As a standard, an intragate multislice FLASH sequence with an acquisition time of 4.5 min per slice was used to produce standard Cine movies of 4 mice hearts with 15 frames per cardiac cycle. The proposed self-gated sequence is used to produce Cine movies with short echo time. The total scan time was 11 min per slice. 6 slices were planned to cover the heart from the base to the apex. 2X, 4X and 6X under-sampled k-spaces cine movies were produced from 2, 1 and 0.7 min data acquisitions for each slice. The accelerated cine movies of the mouse hearts were successfully reconstructed with a compressed sensing algorithm. Compared to the FLASH cine images, the UTE images showed much less flow artifacts due to the short echo time. Besides, the accelerated movies had high image quality and the undersampling artifacts were effectively removed. Left ventricular functional parameters derived from the standard and the accelerated cine movies were nearly identical.
Zweerink, Alwin; Allaart, Cornelis P; Kuijer, Joost P A; Wu, LiNa; Beek, Aernout M; van de Ven, Peter M; Meine, Mathias; Croisille, Pierre; Clarysse, Patrick; van Rossum, Albert C; Nijveldt, Robin
2017-12-01
Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. • Myocardial strain analysis could potentially improve patient selection for CRT. • Currently a well validated clinical approach to derive segmental strains is lacking. • The novel SLICE technique derives segmental strains from standard CMR cine images. • SLICE-derived strain markers of CRT response showed close agreement with CMR-TAG. • Future studies will focus on the prognostic value of SLICE in CRT candidates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riegel, Adam C. B.A.; Chang, Joe Y.; Vedam, Sastry S.
2009-02-01
Purpose: To determine whether cine computed tomography (CT) can serve as an alternative to four-dimensional (4D)-CT by providing tumor motion information and producing equivalent target volumes when used to contour in radiotherapy planning without a respiratory surrogate. Methods and Materials: Cine CT images from a commercial CT scanner were used to form maximum intensity projection and respiratory-averaged CT image sets. These image sets then were used together to define the targets for radiotherapy. Phantoms oscillating under irregular motion were used to assess the differences between contouring using cine CT and 4D-CT. We also retrospectively reviewed the image sets for 26more » patients (27 lesions) at our institution who had undergone stereotactic radiotherapy for Stage I non-small-cell lung cancer. The patients were included if the tumor motion was >1 cm. The lesions were first contoured using maximum intensity projection and respiratory-averaged CT image sets processed from cine CT and then with 4D-CT maximum intensity projection and 10-phase image sets. The mean ratios of the volume magnitude were compared with intraobserver variation, the mean centroid shifts were calculated, and the volume overlap was assessed with the normalized Dice similarity coefficient index. Results: The phantom studies demonstrated that cine CT captured a greater extent of irregular tumor motion than did 4D-CT, producing a larger tumor volume. The patient studies demonstrated that the gross tumor defined using cine CT imaging was similar to, or slightly larger than, that defined using 4D-CT. Conclusion: The results of our study have shown that cine CT is a promising alternative to 4D-CT for stereotactic radiotherapy planning.« less
Cardiac cine imaging at 3 Tesla: initial experience with a 32-element body-array coil.
Fenchel, Michael; Deshpande, Vibhas S; Nael, Kambiz; Finn, J Paul; Miller, Stephan; Ruehm, Stefan; Laub, Gerhard
2006-08-01
We sought to assess the feasibility of cardiac cine imaging and evaluate image quality at 3 T using a body-array coil with 32 coil elements. Eight healthy volunteers (3 men; median age 29 years) were examined on a 3-T magnetic resonance scanner (Magnetom Trio, Siemens Medical Solutions) using a 32-element phased-array coil (prototype from In vivo Corp.). Gradient-recalled-echo (GRE) cine (GRAPPAx3), GRE cine with tagging lines, steady-state-free-precession (SSFP) cine (GRAPPAx3 and x4), and SSFP cine(TSENSEx4 andx6) images were acquired in short-axis and 4-chamber view. Reference images with identical scan parameters were acquired using the total-imaging-matrix (Tim) coil system with a total of 12 coil elements. Images were assessed by 2 observers in a consensus reading with regard to image quality, noise and presence of artifacts. Furthermore, signal-to-noise values were determined in phantom measurements. In phantom measurements signal-to-noise values were increased by 115-155% for the various cine sequences using the 32-element coil. Scoring of image quality yielded statistically significant increased image quality with the SSFP-GRAPPAx4, SSFP-TSENSEx4, and SSFP-TSENSEx6 sequence using the 32-element coil (P < 0.05). Similarly, scoring of image noise yielded a statistically significant lower noise rating with the SSFP-GRAPPAx4, GRE-GRAPPAx3, SSFP-TSENSEx4, and SSFP-TSENSEx6 sequence using the 32-element coil (P < 0.05). This study shows that cardiac cine imaging at 3 T using a 32-element body-array coil is feasible in healthy volunteers. Using a large number of coil elements with a favorable sensitivity profile supports faster image acquisition, with high diagnostic image quality even for high parallel imaging factors.
SU-E-J-192: Verification of 4D-MRI Internal Target Volume Using Cine MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lafata, K; Czito, B; Palta, M
Purpose: To investigate the accuracy of 4D-MRI in determining the Internal Target Volume (ITV) used in radiation oncology treatment planning of liver cancers. Cine MRI is used as the standard baseline in establishing the feasibility and accuracy of 4D-MRI tumor motion within the liver. Methods: IRB approval was obtained for this retrospective study. Analysis was performed on MR images from four patients receiving external beam radiation therapy for liver cancer at our institution. Eligible patients received both Cine and 4D-MRI scans before treatment. Cine images were acquired sagittally in real time at a slice bisecting the tumor, while 4D imagesmore » were acquired volumetrically. Cine MR DICOM headers were manipulated such that each respiratory frame was assigned a unique slice location. This approach permitted the treatment planning system (Eclipse, Varian Medical Systems) to recognize a complete respiratory cycle as a “volume”, where the gross tumor was contoured temporally. Software was developed to calculate the union of all frame contours in the structure set, resulting in the corresponding plane of the ITV projecting through the middle of the tumor, defined as the Internal Target Area (ITA). This was repeated for 4D-MRI, at the corresponding slice location, allowing a direct comparison of ITAs obtained from each modality. Results: Four patients have been analyzed. ITAs contoured from 4D-MRI correlate with contours from Cine MRI. The mean error of 4D values relative to Cine values is 7.67 +/− 2.55 %. No single ITA contoured from 4D-MRI demonstrated more than 10.5 % error compared to its Cine MRI counterpart. Conclusion: Motion management is a significant aspect of treatment planning within dynamic environments such as the liver, where diaphragmatic and cardiac activity influence plan accuracy. This small pilot study suggests that 4D-MRI based ITA measurements agree with Cine MRI based measurements, an important step towards clinical implementation. NIH 1R21CA165384-01A1.« less
Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun
2008-12-15
Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACTmore » from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma ({gamma}) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass {gamma} criteria. The average maximum and mean {gamma} indices were very low (well below 1), indicating good agreement between dose distributions. Increasing the cine duration generally increased the dose agreement. In the follow-up study, 49 of 50 patients had 100% of points within the PTV pass the {gamma} criteria. The average maximum and mean {gamma} indices were again well below 1, indicating good agreement. Dose calculation on RACT from cine CT is negligibly different from dose calculation on RACT from 4D-CT. Differences can be decreased further by increasing the cine duration of the cine CT scan.« less
Randall, David; Joosten, Frank; ten Broek, Richard; Gillott, Richard; Bardhan, Karna Dev; Strik, Chema; Prins, Wiesje; van Goor, Harry; Fenner, John
2017-07-14
A non-invasive diagnostic technique for abdominal adhesions is not currently available. Capture of abdominal motion due to respiration in cine-MRI has shown promise, but is difficult to interpret. This article explores the value of a complimentary diagnostic aid to facilitate the non-invasive detection of abdominal adhesions using cine-MRI. An image processing technique was developed to quantify the amount of sliding that occurs between the organs of the abdomen and the abdominal wall in sagittal cine-MRI slices. The technique produces a 'sheargram' which depicts the amount of sliding which has occurred over 1-3 respiratory cycles. A retrospective cohort of 52 patients, scanned for suspected adhesions, made 281 cine-MRI sagittal slices available for processing. The resulting sheargrams were reported by two operators and compared to expert clinical judgement of the cine-MRI scans. The sheargram matched clinical judgement in 84% of all sagittal slices and 93-96% of positive adhesions were identified on the sheargram. The sheargram displayed a slight skew towards sensitivity over specificity, with a high positive adhesion detection rate but at the expense of false positives. Good correlation between sheargram and absence/presence of inferred adhesions indicates quantification of sliding motion has potential to aid adhesion detection in cine-MRI. Advances in Knowledge: This is the first attempt to clinically evaluate a novel image processing technique quantifying the sliding motion of the abdominal contents against the abdominal wall. The results of this pilot study reveal its potential as a diagnostic aid for detection of abdominal adhesions.
Starling, M R; Gross, M D; Walsh, R A; Dell'Italia, L J; Montgomery, D G; Squicciarini, S A; Blumhardt, R
1988-08-01
This investigation was designed to determine whether left ventricular (LV) maximum time-varying elastance (Emax) calculations obtained using equilibrium radionuclide angiography (RNA) were comparable to those obtained using biplane contrast cineangiography (CINE), and whether simple, indirect P-V relations might provide reasonable, alternative estimates of Emax. Accordingly, we studied 19 patients with simultaneous high-fidelity micromanometer LV and fluid brachial artery (Ba) pressure recordings, CINE, and RNA under control conditions and during methoxamine and nitroprusside infusions. Emax was defined for CINE and RNA as the maximum slope of the linear relation of isochronal, instantaneous P-V data points obtained from each of the three loading conditions. The indirect P-V relations were similarly obtained from Ba peak (P) pressure versus minimum RNA LV volume (BaP/minV) and Ba dicrotic notch (di) pressure versus minimum RNA LV volume (Badi/minV) data points. The mean heart rates and LV (+)dP/dtmax values were minimally altered during the three loading conditions. The isochronal Emax values ranged from 1.40 to 6.73 mmHg/ml (mean 4.13 +/- 1.99 s.d. mmHg/ml) for CINE and from 1.48 to 7.25 (mean 4.35 +/- 1.81 mmHg/ml) for RNA (p = N.S.). Similarly, the unstressed volumes ranged from -10 to 80 ml (mean 30 +/- 23 ml) for CINE and from -8 to 77 ml (29 +/- 21 ml) for RNA (p = N.S.). The individual, isochronal Emax values by RNA correlated with those by CINE (r = 0.86). In 14 of the 19 patients, the BaP/minV and Badi/minV relations correlated with the isochronal Emax values calculated by RNA (r = 0.83 and 0.82, respectively), and these relations also correlated with the Emax values calculated by CINE (r = 0.82 and 0.78, respectively). The slope and V0 values for the BaP/minV and Badi/minV relations underestimated those for Emax by RNA and CINE (p less than 0.01 and p less than 0.05, respectively, for both). Thus, the isochronal Emax values calculated using RNA are comparable to those obtained using CINE in man. Moreover, indirect P-V relations underestimate these Emax values, but they are linearly related with the isochronal Emax values calculated by RNA and CINE. Consequently, these indirect P-V relations may provide a more simple, alternative estimate of LV contractile function in man.
Vector Flow Visualization of Urinary Flow Dynamics in a Bladder Outlet Obstruction Model.
Ishii, Takuro; Yiu, Billy Y S; Yu, Alfred C H
2017-11-01
Voiding dysfunction that results from bladder outlet (BO) obstruction is known to alter significantly the dynamics of urine passage through the urinary tract. To non-invasively image this phenomenon on a time-resolved basis, we pursued the first application of a recently developed flow visualization technique called vector projectile imaging (VPI) that can track the spatiotemporal dynamics of flow vector fields at a frame rate of 10,000 fps (based on plane wave excitation and least-squares Doppler vector estimation principles). For this investigation, we designed a new anthropomorphic urethral tract phantom to reconstruct urinary flow dynamics under controlled conditions (300 mm H 2 O inlet pressure and atmospheric outlet pressure). Both a normal model and a diseased model with BO obstruction were developed for experimentation. VPI cine loops were derived from these urinary flow phantoms. Results show that VPI is capable of depicting differences in the flow dynamics of normal and diseased urinary tracts. In the case with BO obstruction, VPI depicted the presence of BO flow jet and vortices in the prostatic urethra. The corresponding spatial-maximum flow velocity magnitude was estimated to be 2.43 m/s, and it is significantly faster than that for the normal model (1.52 m/s) and is in line with values derived from computational fluid dynamics simulations. Overall, this investigation demonstrates the feasibility of using vector flow visualization techniques to non-invasively examine internal flow characteristics related to voiding dysfunction in the urethral tract. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes
NASA Astrophysics Data System (ADS)
Bjerre, Troels; Crijns, Sjoerd; Rosenschöld, Per Munck af; Aznar, Marianne; Specht, Lena; Larsen, Rasmus; Keall, Paul
2013-07-01
The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-treatment 3D breath-hold scan, extracting a 3D target template and performing template matching between this 3D template and pairs of orthogonal 2D cine-MRI planes intersecting the target motion path. For a 60 s free-breathing series of orthogonal cine-MRI planes, we demonstrate that the method was capable of accurately tracking the respiration related 3D motion of the left kidney. Quantitative evaluation of the method using a dataset designed for this purpose revealed a translational error of 1.15 mm for a translation of 39.9 mm. We have demonstrated how interleaved acquired, orthogonal cine-MRI planes can be used for online tracking of soft-tissue target volumes.
Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes.
Bjerre, Troels; Crijns, Sjoerd; af Rosenschöld, Per Munck; Aznar, Marianne; Specht, Lena; Larsen, Rasmus; Keall, Paul
2013-07-21
The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-treatment 3D breath-hold scan, extracting a 3D target template and performing template matching between this 3D template and pairs of orthogonal 2D cine-MRI planes intersecting the target motion path. For a 60 s free-breathing series of orthogonal cine-MRI planes, we demonstrate that the method was capable of accurately tracking the respiration related 3D motion of the left kidney. Quantitative evaluation of the method using a dataset designed for this purpose revealed a translational error of 1.15 mm for a translation of 39.9 mm. We have demonstrated how interleaved acquired, orthogonal cine-MRI planes can be used for online tracking of soft-tissue target volumes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, W; Yin, F; Wang, C
Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution ofmore » VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.« less
Recent experience with design and manufacture of cine lenses
NASA Astrophysics Data System (ADS)
Thorpe, Michael D.; Dalzell, Kristen E.
2015-09-01
Modern cine lenses require a high degree of aberration correction over a large and ever expanding image size. At low to medium volume production levels, these highly corrected designs also require a workable tolerance set and compensation scheme for successful manufacture. In this paper we discuss the design and manufacture of cine lenses with reference to current designs both internal and in the patent literature and some experience in design, tolerancing and manufacturing these lenses in medium volume production.
Ta, Casey N; Eghtedari, Mohammad; Mattrey, Robert F; Kono, Yuko; Kummel, Andrew C
2014-11-01
Contrast-enhanced ultrasound (CEUS) cines of focal liver lesions (FLLs) can be quantitatively analyzed to measure tumor perfusion on a pixel-by-pixel basis for diagnostic indication. However, CEUS cines acquired freehand and during free breathing cause nonuniform in-plane and out-of-plane motion from frame to frame. These motions create fluctuations in the time-intensity curves (TICs), reducing the accuracy of quantitative measurements. Out-of-plane motion cannot be corrected by image registration in 2-dimensional CEUS and degrades the quality of in-plane motion correction (IPMC). A 2-tier IPMC strategy and adaptive out-of-plane motion filter (OPMF) are proposed to provide a stable correction of nonuniform motion to reduce the impact of motion on quantitative analyses. A total of 22 cines of FLLs were imaged with dual B-mode and contrast specific imaging to acquire a 3-minute TIC. B-mode images were analyzed for motion, and the motion correction was applied to both B-mode and contrast images. For IPMC, the main reference frame was automatically selected for each cine, and subreference frames were selected in each respiratory cycle and sequentially registered toward the main reference frame. All other frames were sequentially registered toward the local subreference frame. Four OPMFs were developed and tested: subsample normalized correlation (NC), subsample sum of absolute differences, mean frame NC, and histogram. The frames that were most dissimilar to the OPMF reference frame using 1 of the 4 above criteria in each respiratory cycle were adaptively removed by thresholding against the low-pass filter of the similarity curve. Out-of-plane motion filter was quantitatively evaluated by an out-of-plane motion metric (OPMM) that measured normalized variance in the high-pass filtered TIC within the tumor region-of-interest with low OPMM being the goal. Results for IPMC and OPMF were qualitatively evaluated by 2 blinded observers who ranked the motion in the cines before and after various combinations of motion correction steps. Quantitative measurements showed that 2-tier IPMC and OPMF improved imaging stability. With IPMC, the NC B-mode metric increased from 0.504 ± 0.149 to 0.585 ± 0.145 over all cines (P < 0.001). Two-tier IPMC also produced better fits on the contrast-specific TIC than industry standard IPMC techniques did (P < 0.02). In-plane motion correction and OPMF were shown to improve goodness of fit for pixel-by-pixel analysis (P < 0.001). Out-of-plane motion filter reduced variance in the contrast-specific signal as shown by a median decrease of 49.8% in the OPMM. Two-tier IPMC and OPMF were also shown to qualitatively reduce motion. Observers consistently ranked cines with IPMC higher than the same cine before IPMC (P < 0.001) as well as ranked cines with OPMF higher than when they were uncorrected. The 2-tier sequential IPMC and adaptive OPMF significantly reduced motion in 3-minute CEUS cines of FLLs, thereby overcoming the challenges of drift and irregular breathing motion in long cines. The 2-tier IPMC strategy provided stable motion correction tolerant of out-of-plane motion throughout the cine by sequentially registering subreference frames that bypassed the motion cycles, thereby overcoming the lack of a nearly stationary reference point in long cines. Out-of-plane motion filter reduced apparent motion by adaptively removing frames imaged off-plane from the automatically selected OPMF reference frame, thereby tolerating nonuniform breathing motion. Selection of the best OPMF by minimizing OPMM effectively reduced motion under a wide variety of motion patterns applicable to clinical CEUS. These semiautomated processes only required user input for region-of-interest selection and can improve the accuracy of quantitative perfusion measurements.
NASA Astrophysics Data System (ADS)
Ting, Chien-Yi; Chen, Zhih-Cherng; Tang, Kuo-Ting; Liu, Wei-Chung; Lin, Chun-Chih; Wang, Hsin-Ell
2015-12-01
Coronary angiogram is an imperative tool for diagnosis of coronary artery diseases, in which cine-angiography is a commonly used method. Although the angiography proceeds under radiation, the potential risk of radiation exposure for both the patients and the operators was seldom noticed. In this study, the absorbed radiation dose in stored-fluorography mode was compared with that in cine-angiography mode by using optically simulated luminescent dosimeters to realize their effects on radiation dose. Patients received coronary angiogram via radial artery approach were randomized into the stored-fluorography group (N=30) or the cine-angiography group (N=30). The excluded criteria were: 1. women at pregnancy or on breast feeding, 2. chronic kidney diseases with glomerular filtration rate less than 60 mL/min. During the coronary angiogram, absorbed dose of the patients and the operator radiation exposure was measured with optically simulated luminescent dosimeter (OSLD). The absorbed dose of the patients in the stored-fluorography group (3.13±0.25 mGy) was apparently lower than that in the cine-angiography group (65.57±5.37 mGy; P<0.001). For the operator, a statistical difference (P<0.001) was also found between the stored-fluorography group (0.09163 μGy) and the cine-angiography (0.6519μGy). Compared with traditional cine-angiography mode, the stored-fluorography mode can apparently reduce radiation exposure of the patients and the operator in coronary angiogram.
Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT.
Pan, Tinsu
2005-02-01
We proposed a data sufficiency condition (DSC) for four-dimensional-CT (4D-CT) imaging on a multislice CT scanner, designed a pitch factor for a helical 4D-CT, and compared the acquisition time, slice sensitivity profile (SSP), effective dose, ability to cope with an irregular breathing cycle, and gating technique (retrospective or prospective) of the helical 4D-CT and the cine 4D-CT on the General Electric (GE) LightSpeed RT (4-slice), Plus (4-slice), Ultra (8-slice) and 16 (16-slice) multislice CT scanners. To satisfy the DSC, a helical or cine 4D-CT acquisition has to collect data at each location for the duration of a breathing cycle plus the duration of data acquisition for an image reconstruction. The conditions for the comparison were 20 cm coverage in the cranial-caudal direction, a 4 s breathing cycle, and half-scan reconstruction. We found that the helical 4D-CT has the advantage of a shorter scan time that is 10% shorter than that of the cine 4D-CT, and the disadvantages of 1.8 times broadening of SSP and requires an additional breathing cycle of scanning to ensure an adequate sampling at the start and end locations. The cine 4D-CT has the advantages of maintaining the same SSP as slice collimation (e.g., 8 x 2.5 mm slice collimation generates 2.5 mm SSP in the cine 4D-CT as opposed to 4.5 mm in the helical 4D-CT) and a lower dose by 4% on the 8- and 16-slice systems, and 8% on the 4-slice system. The advantage of faster scanning in the helical 4D-CT will diminish if a repeat scan at the location of a breathing irregularity becomes necessary. The cine 4D-CT performs better than the helical 4D-CT in the repeat scan because it can scan faster and is more dose efficient.
Thales Angenieux: 42 years of cine 35 mm zoom leadership
NASA Astrophysics Data System (ADS)
Debize, Jacques
2004-02-01
Since the early years of zoom optics, Angenieux has been involved in cine 8 mm, 16 mm and 35 mm. Among more than twenty different zoom lenses, four of them have been milestones in this field, technical progresses being sanctified by two Oscars in 1964 and 1990. From 1960 to 2002 Angenieux has created first the 4 x 35 LA2, the first four times mechanically compensated zoom lens for cine 35 mm in the world, secondary the 10 x 25 T2, the first ten times mechanically compensated zoom lens for cine 35 mm in the world, then the 10 x 25 HR, the top level of quality for its category and finally the 12 x 24 Optimo with all characteristics and performances greatly increased. This leadership has been reached thanks to computers and in-house softwares but also thanks to new manufacturing processes.
NASA Astrophysics Data System (ADS)
Tang, Xiaoli; Lin, Tong; Jiang, Steve
2009-09-01
We propose a novel approach for potential online treatment verification using cine EPID (electronic portal imaging device) images for hypofractionated lung radiotherapy based on a machine learning algorithm. Hypofractionated radiotherapy requires high precision. It is essential to effectively monitor the target to ensure that the tumor is within the beam aperture. We modeled the treatment verification problem as a two-class classification problem and applied an artificial neural network (ANN) to classify the cine EPID images acquired during the treatment into corresponding classes—with the tumor inside or outside of the beam aperture. Training samples were generated for the ANN using digitally reconstructed radiographs (DRRs) with artificially added shifts in the tumor location—to simulate cine EPID images with different tumor locations. Principal component analysis (PCA) was used to reduce the dimensionality of the training samples and cine EPID images acquired during the treatment. The proposed treatment verification algorithm was tested on five hypofractionated lung patients in a retrospective fashion. On average, our proposed algorithm achieved a 98.0% classification accuracy, a 97.6% recall rate and a 99.7% precision rate. This work was first presented at the Seventh International Conference on Machine Learning and Applications, San Diego, CA, USA, 11-13 December 2008.
Shiozaki, H
1993-01-25
The usefulness of cine magnetic resonance (MR) imaging was evaluated in 41 patients with acute (4 cases), subacute (21 cases) and chronic (16 cases) myocardial infarctions on the basis of the findings of thallium-201 myocardial SPECT. The overall rate of diagnostic accordance between cine MR imaging and SPECT was 85.0% (408/480). It was highest at the middle of the left ventricle (89.0%, 146/164) and lowest at the base (82.7%, 129/156). Measurement of wall thickness using the images printed on films was possible in 87.1% of segments (418/480). There was a significant difference in end-diastolic wall thickness and %-thickening between the infarcted and non-infarcted sites except for the base of the left ventricle. However, diastolic wall thinning was not remarkable in acute cases of less than one week after onset. In these cases %-thickening may be useful. Partial volume averaging on MR imaging and the inaccuracy of SPECT findings at the base also made meaningful comparison difficult. The most important diagnostic findings of myocardial infarction on cine MR imaging were end-diastolic wall thinning and abnormal motion such as akinesis and dyskinesis. It is concluded that cine MR imaging is a useful noninvasive examination method for evaluating the status of cardiac function in myocardial infarction.
Satriano, Alessandro; Heydari, Bobak; Narous, Mariam; Exner, Derek V; Mikami, Yoko; Attwood, Monica M; Tyberg, John V; Lydell, Carmen P; Howarth, Andrew G; Fine, Nowell M; White, James A
2017-12-01
Two-dimensional (2D) strain analysis is constrained by geometry-dependent reference directions of deformation (i.e. radial, circumferential, and longitudinal) following the assumption of cylindrical chamber architecture. Three-dimensional (3D) principal strain analysis may overcome such limitations by referencing intrinsic (i.e. principal) directions of deformation. This study aimed to demonstrate clinical feasibility of 3D principal strain analysis from routine 2D cine MRI with validation to strain from 2D tagged cine analysis and 3D speckle tracking echocardiography. Thirty-one patients undergoing cardiac MRI were studied. 3D strain was measured from routine, multi-planar 2D cine SSFP images using custom software designed to apply 4D deformation fields to 3D cardiac models to derive principal strain. Comparisons of strain estimates versus those by 2D tagged cine, 2D non-tagged cine (feature tracking), and 3D speckle tracking echocardiography (STE) were performed. Mean age was 51 ± 14 (36% female). Mean LV ejection fraction was 66 ± 10% (range 37-80%). 3D principal strain analysis was feasible in all subjects and showed high inter- and intra-observer reproducibility (ICC range 0.83-0.97 and 0.83-0.98, respectively-p < 0.001 for all directions). Strong correlations of minimum and maximum principal strain were respectively observed versus the following: 3D STE estimates of longitudinal (r = 0.81 and r = -0.64), circumferential (r = 0.76 and r = -0.58) and radial (r = -0.80 and r = 0.63) strain (p < 0.001 for all); 2D tagged cine estimates of longitudinal (r = 0.81 and r = -0.81), circumferential (r = 0.87 and r = -0.85), and radial (r = -0.76 and r = 0.81) strain (p < 0.0001 for all); and 2D cine (feature tracking) estimates of longitudinal (r = 0.85 and -0.83), circumferential (r = 0.88 and r = -0.87), and radial strain (r = -0.79 and r = 0.84, p < 0.0001 for all). 3D principal strain analysis is feasible using routine, multi-planar 2D cine MRI and shows high reproducibility with strong correlations to 2D conventional strain analysis and 3D STE-based analysis. Given its independence from geometry-related directions of deformation this technique may offer unique benefit for the detection and prognostication of myocardial disease, and warrants expanded investigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandes, Annemarie T.; Apisarnthanarax, Smith; Yin, Lingshu
Purpose: To compare the extent of tumor motion between 4-dimensional CT (4DCT) and cine-MRI in patients with hepatic tumors treated with radiation therapy. Methods and Materials: Patients with liver tumors who underwent 4DCT and 2-dimensional biplanar cine-MRI scans during simulation were retrospectively reviewed to determine the extent of target motion in the superior–inferior, anterior–posterior, and lateral directions. Cine-MRI was performed over 5 minutes. Tumor motion from MRI was determined by tracking the centroid of the gross tumor volume using deformable image registration. Motion estimates from 4DCT were performed by evaluation of the fiducial, residual contrast (or liver contour) positions in eachmore » CT phase. Results: Sixteen patients with hepatocellular carcinoma (n=11), cholangiocarcinoma (n=3), and liver metastasis (n=2) were reviewed. Cine-MRI motion was larger than 4DCT for the superior–inferior direction in 50% of patients by a median of 3.0 mm (range, 1.5-7 mm), the anterior–posterior direction in 44% of patients by a median of 2.5 mm (range, 1-5.5 mm), and laterally in 63% of patients by a median of 1.1 mm (range, 0.2-4.5 mm). Conclusions: Cine-MRI frequently detects larger differences in hepatic intrafraction tumor motion when compared with 4DCT most notably in the superior–inferior direction, and may be useful when assessing the need for or treating without respiratory management, particularly in patients with unreliable 4DCT imaging. Margins wider than the internal target volume as defined by 4DCT were required to encompass nearly all the motion detected by cine-MRI for some of the patients in this study.« less
Dinçer, Alp; Yildiz, Erdem; Kohan, Saeed; Memet Özek, M
2011-01-01
The aim of the study is to evaluate the efficiency of turbo spin-echo (TSE), three-dimensional constructive interference in the steady state (3D CISS) and cine phase contrast (Cine PC) sequences in determining flow through the endoscopic third ventriculostomy (ETV) fenestration, and to determine the effect of various TSE sequence parameters. The study was approved by our institutional review board and informed consent from all patients was obtained. Two groups of patients were included: group I (24 patients with good clinical outcome after ETV) and group II (22 patients with hydrocephalus evaluated preoperatively). The imaging protocol for both groups was identical. TSE T2 with various sequence parameters and imaging planes, and 3D CISS, followed by cine PC were obtained. Flow void was graded as four-point scales. The sensitivity, specificity, accuracy, positive and negative predictive values of sequences were calculated. Bidirectional flow through the fenestration was detected in all group I patients by cine PC. Stroke volumes through the fenestration in group I ranged 10-160.8 ml/min. There was no correlation between the presence of reversed flow and flow void grading. Also, there was no correlation between the stroke volumes and flow void grading. The sensitivity of 3D CISS was low, and 2 mm sagittal TSE T2, nearly equal to cine PC, provided best result. Cine PC and TSE T2 both have high confidence in the assessment of the flow through the fenestration. But, sequence parameters significantly affect the efficiency of TSE T2.
Gouya, Hervé; Grabar, Sophie; Vignaux, Olivier; Saade, Anastasia; Pol, Stanislas; Legmann, Paul; Sogni, Philippe
2016-07-01
To measure azygos, portal and aortic flow by two-dimensional cine phase-contrast magnetic resonance imaging (2D-cine PC MRI), and to compare the MRI values to hepatic venous pressure gradient (HVPG) measurements, in patients with cirrhosis. Sixty-nine patients with cirrhosis were prospectively included. All patients underwent HVPG measurements, upper gastrointestinal endoscopy and 2D-cine PC MRI measurements of azygos, portal and aortic blood flow. Univariate and multivariate regression analyses were used to evaluate the correlation between the blood flow and HVPG. The performance of 2D-cine PC MRI to diagnose severe portal hypertension (HVPG ≥ 16 mmHg) was determined by receiver operating characteristic curve (ROC) analysis, and area under the curves (AUC) were compared. Azygos and aortic flow values were associated with HVPG in univariate linear regression model. Azygos flow (p < 10(-3)), aortic flow (p = 0.001), age (p = 0.001) and presence of varices (p < 10(-3)) were independently associated with HVPG. Azygos flow (AUC = 0.96 (95 % CI [0.91-1.00]) had significantly higher AUC than aortic (AUC = 0.64 (95 % CI [0.51-0.77]) or portal blood flow (AUC = 0.40 (95 % CI [0.25-0.54]). 2D-cine PC MRI is a promising technique to evaluate significant portal hypertension in patients with cirrhosis. • Noninvasive HVPG assessment can be performed with MRI azygos flow. • Azygos MRI flow is an easy-to-measure marker to detect significant portal hypertension. • MRI flow is more specific that varice grade to detect portal hypertension.
Kim, D S; Choi, J U; Huh, R; Yun, P H; Kim, D I
1999-09-01
This investigation was undertaken to characterize CSF flow at the level of the aqueduct of Sylvius with a phase-contrast cine MR pulse sequence in 28 healthy volunteers. Sixteen patients with obstructive hydrocephalus and 11 patients with normal pressure hydrocephalus (NPH) were investigated with the same sequence before and after CSF diversion. The peak CSF flow velocity and stroke volume in the aqueduct increased significantly in the NPH group and decreased significantly in the obstructive hydrocephalus group. After lumboperitoneal shunting in the NPH group, the retrograde flow of CSF was anterogradely converted and the peak flow velocities decreased somewhat. The clinical diagnosis of NPH was well correlated with the results of cine MRI. After endoscopic III ventriculostomy in the obstructive hydrocephalus group we noted increased CSF flow velocity with markedly increased stroke volume at the prepontine cistern. Phase-contrast cine MR is useful in evaluating CSF dynamics in patients with hyperdynamic aqueductal CSF or aqueductal obstruction.
Measurement of complex joint trajectories using slice-to-volume 2D/3D registration and cine MR
NASA Astrophysics Data System (ADS)
Bloch, C.; Figl, M.; Gendrin, C.; Weber, C.; Unger, E.; Aldrian, S.; Birkfellner, W.
2010-02-01
A method for studying the in vivo kinematics of complex joints is presented. It is based on automatic fusion of single slice cine MR images capturing the dynamics and a static MR volume. With the joint at rest the 3D scan is taken. In the data the anatomical compartments are identified and segmented resulting in a 3D volume of each individual part. In each of the cine MR images the joint parts are segmented and their pose and position are derived using a 2D/3D slice-to-volume registration to the volumes. The method is tested on the carpal joint because of its complexity and the small but complex motion of its compartments. For a first study a human cadaver hand was scanned and the method was evaluated with artificially generated slice images. Starting from random initial positions of about 5 mm translational and 12° rotational deviation, 70 to 90 % of the registrations converged successfully to a deviation better than 0.5 mm and 5°. First evaluations using real data from a cine MR were promising. The feasibility of the method was demonstrated. However we experienced difficulties with the segmentation of the cine MR images. We therefore plan to examine different parameters for the image acquisition in future studies.
Compressed sensing reconstruction of cardiac cine MRI using golden angle spiral trajectories
NASA Astrophysics Data System (ADS)
Tolouee, Azar; Alirezaie, Javad; Babyn, Paul
2015-11-01
In dynamic cardiac cine Magnetic Resonance Imaging (MRI), the spatiotemporal resolution is limited by the low imaging speed. Compressed sensing (CS) theory has been applied to improve the imaging speed and thus the spatiotemporal resolution. The purpose of this paper is to improve CS reconstruction of under sampled data by exploiting spatiotemporal sparsity and efficient spiral trajectories. We extend k-t sparse algorithm to spiral trajectories to achieve high spatio temporal resolutions in cardiac cine imaging. We have exploited spatiotemporal sparsity of cardiac cine MRI by applying a 2D + time wavelet-Fourier transform. For efficient coverage of k-space, we have used a modified version of multi shot (interleaved) spirals trajectories. In order to reduce incoherent aliasing artifact, we use different random undersampling pattern for each temporal frame. Finally, we have used nonuniform fast Fourier transform (NUFFT) algorithm to reconstruct the image from the non-uniformly acquired samples. The proposed approach was tested in simulated and cardiac cine MRI data. Results show that higher acceleration factors with improved image quality can be obtained with the proposed approach in comparison to the existing state-of-the-art method. The flexibility of the introduced method should allow it to be used not only for the challenging case of cardiac imaging, but also for other patient motion where the patient moves or breathes during acquisition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Hua, E-mail: huli@radonc.wustl.edu; Chen, Hsin
Purpose: For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. Methods: Considering the complex H&N structures andmore » ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity coefficient (93.28% ± 1.46%) and margin error (0.49 ± 0.12 mm) showed good agreement between the automatic and manual results. The comparison with three other deformable model-based segmentation methods illustrated the superior shape tracking performance of the proposed method. Large interpatient variations of swallowing frequency, swallowing duration, and upper airway cross-sectional area were observed from the testing cine image sequences. Conclusions: The proposed motion tracking method can provide accurate upper airway motion tracking results, and enable automatic and quantitative identification and analysis of in-treatment H&N upper airway motion. By integrating explicit and implicit linked-shape representations within a hierarchical model-fitting process, the proposed tracking method can process complex H&N structures and low-contrast/resolution cine MRI images. Future research will focus on the improvement of method reliability, patient motion pattern analysis for providing more information on patient-specific prediction of structure displacements, and motion effects on dosimetry for better H&N motion management in radiation therapy.« less
Li, Hua; Chen, Hsin-Chen; Dolly, Steven; Li, Harold; Fischer-Valuck, Benjamin; Victoria, James; Dempsey, James; Ruan, Su; Anastasio, Mark; Mazur, Thomas; Gach, Michael; Kashani, Rojano; Green, Olga; Rodriguez, Vivian; Gay, Hiram; Thorstad, Wade; Mutic, Sasa
2016-08-01
For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. Considering the complex H&N structures and ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity coefficient (93.28% ± 1.46%) and margin error (0.49 ± 0.12 mm) showed good agreement between the automatic and manual results. The comparison with three other deformable model-based segmentation methods illustrated the superior shape tracking performance of the proposed method. Large interpatient variations of swallowing frequency, swallowing duration, and upper airway cross-sectional area were observed from the testing cine image sequences. The proposed motion tracking method can provide accurate upper airway motion tracking results, and enable automatic and quantitative identification and analysis of in-treatment H&N upper airway motion. By integrating explicit and implicit linked-shape representations within a hierarchical model-fitting process, the proposed tracking method can process complex H&N structures and low-contrast/resolution cine MRI images. Future research will focus on the improvement of method reliability, patient motion pattern analysis for providing more information on patient-specific prediction of structure displacements, and motion effects on dosimetry for better H&N motion management in radiation therapy.
SVM-based classification of LV wall motion in cardiac MRI with the assessment of STE
NASA Astrophysics Data System (ADS)
Mantilla, Juan; Garreau, Mireille; Bellanger, Jean-Jacques; Paredes, José Luis
2015-01-01
In this paper, we propose an automated method to classify normal/abnormal wall motion in Left Ventricle (LV) function in cardiac cine-Magnetic Resonance Imaging (MRI), taking as reference, strain information obtained from 2D Speckle Tracking Echocardiography (STE). Without the need of pre-processing and by exploiting all the images acquired during a cardiac cycle, spatio-temporal profiles are extracted from a subset of radial lines from the ventricle centroid to points outside the epicardial border. Classical Support Vector Machines (SVM) are used to classify features extracted from gray levels of the spatio-temporal profile as well as their representations in the Wavelet domain under the assumption that the data may be sparse in that domain. Based on information obtained from radial strain curves in 2D-STE studies, we label all the spatio-temporal profiles that belong to a particular segment as normal if the peak systolic radial strain curve of this segment presents normal kinesis, or abnormal if the peak systolic radial strain curve presents hypokinesis or akinesis. For this study, short-axis cine- MR images are collected from 9 patients with cardiac dyssynchrony for which we have the radial strain tracings at the mid-papilary muscle obtained by 2D STE; and from one control group formed by 9 healthy subjects. The best classification performance is obtained with the gray level information of the spatio-temporal profiles using a RBF kernel with 91.88% of accuracy, 92.75% of sensitivity and 91.52% of specificity.
NASA Astrophysics Data System (ADS)
Ting, Samuel T.
The research presented in this work seeks to develop, validate, and deploy practical techniques for improving diagnosis of cardiovascular disease. In the philosophy of biomedical engineering, we seek to identify an existing medical problem having significant societal and economic effects and address this problem using engineering approaches. Cardiovascular disease is the leading cause of mortality in the United States, accounting for more deaths than any other major cause of death in every year since 1900 with the exception of the year 1918. Cardiovascular disease is estimated to account for almost one-third of all deaths in the United States, with more than 2150 deaths each day, or roughly 1 death every 40 seconds. In the past several decades, a growing array of imaging modalities have proven useful in aiding the diagnosis and evaluation of cardiovascular disease, including computed tomography, single photon emission computed tomography, and echocardiography. In particular, cardiac magnetic resonance imaging is an excellent diagnostic tool that can provide within a single exam a high quality evaluation of cardiac function, blood flow, perfusion, viability, and edema without the use of ionizing radiation. The scope of this work focuses on the application of engineering techniques for improving imaging using cardiac magnetic resonance with the goal of improving the utility of this powerful imaging modality. Dynamic cine imaging, or the capturing of movies of a single slice or volume within the heart or great vessel region, is used in nearly every cardiac magnetic resonance imaging exam, and adequate evaluation of cardiac function and morphology for diagnosis and evaluation of cardiovascular disease depends heavily on both the spatial and temporal resolution as well as the image quality of the reconstruction cine images. This work focuses primarily on image reconstruction techniques utilized in cine imaging; however, the techniques discussed are also relevant to other dynamic and static imaging techniques based on cardiac magnetic resonance. Conventional segmented techniques for cardiac cine imaging require breath-holding as well as regular cardiac rhythm, and can be time-consuming to acquire. Inadequate breath-holding or irregular cardiac rhythm can result in completely non-diagnostic images, limiting the utility of these techniques in a significant patient population. Real-time single-shot cardiac cine imaging enables free-breathing acquisition with significantly shortened imaging time and promises to significantly improve the utility of cine imaging for diagnosis and evaluation of cardiovascular disease. However, utility of real-time cine images depends heavily on the successful reconstruction of final cine images from undersampled data. Successful reconstruction of images from more highly undersampled data results directly in images exhibiting finer spatial and temporal resolution provided that image quality is sufficient. This work focuses primarily on the development, validation, and deployment of practical techniques for enabling the reconstruction of real-time cardiac cine images at the spatial and temporal resolutions and image quality needed for diagnostic utility. Particular emphasis is placed on the development of reconstruction approaches resulting in with short computation times that can be used in the clinical environment. Specifically, the use of compressed sensing signal recovery techniques is considered; such techniques show great promise in allowing successful reconstruction of highly undersampled data. The scope of this work concerns two primary topics related to signal recovery using compressed sensing: (1) long reconstruction times of these techniques, and (2) improved sparsity models for signal recovery from more highly undersampled data. Both of these aspects are relevant to the practical application of compressed sensing techniques in the context of improving image reconstruction of real-time cardiac cine images. First, algorithmic and implementational approaches are proposed for reducing the computational time for a compressed sensing reconstruction framework. Specific optimization algorithms based on the fast iterative/shrinkage algorithm (FISTA) are applied in the context of real-time cine image reconstruction to achieve efficient per-iteration computation time. Implementation within a code framework utilizing commercially available graphics processing units (GPUs) allows for practical and efficient implementation directly within the clinical environment. Second, patch-based sparsity models are proposed to enable compressed sensing signal recovery from highly undersampled data. Numerical studies demonstrate that this approach can help improve image quality at higher undersampling ratios, enabling real-time cine imaging at higher acceleration rates. In this work, it is shown that these techniques yield a holistic framework for achieving efficient reconstruction of real-time cine images with spatial and temporal resolution sufficient for use in the clinical environment. A thorough description of these techniques from both a theoretical and practical view is provided - both of which may be of interest to the reader in terms of future work.
Techniques for the Analysis of Human Movement.
ERIC Educational Resources Information Center
Grieve, D. W.; And Others
This book presents the major analytical techniques that may be used in the appraisal of human movement. Chapter 1 is devoted to the photopgraphic analysis of movement with particular emphasis on cine filming. Cine film may be taken with little or no restriction on the performer's range of movement; information on the film is permanent and…
Tissue-Point Motion Tracking in the Tongue from Cine MRI and Tagged MRI
ERIC Educational Resources Information Center
Woo, Jonghye; Stone, Maureen; Suo, Yuanming; Murano, Emi Z.; Prince, Jerry L.
2014-01-01
Purpose: Accurate tissue motion tracking within the tongue can help professionals diagnose and treat vocal tract--related disorders, evaluate speech quality before and after surgery, and conduct various scientific studies. The authors compared tissue tracking results from 4 widely used deformable registration (DR) methods applied to cine magnetic…
Tracking brain motion during the cardiac cycle using spiral cine-DENSE MRI
Zhong, Xiaodong; Meyer, Craig H.; Schlesinger, David J.; Sheehan, Jason P.; Epstein, Frederick H.; Larner, James M.; Benedict, Stanley H.; Read, Paul W.; Sheng, Ke; Cai, Jing
2009-01-01
Cardiac-synchronized brain motion is well documented, but the accurate measurement of such motion on the pixel-by-pixel basis has been hampered by the lack of proper imaging technique. In this article, the authors present the implementation of an autotracking spiral cine displacement-encoded stimulation echo (DENSE) magnetic resonance imaging (MRI) technique for the measurement of pulsatile brain motion during the cardiac cycle. Displacement-encoded dynamic MR images of three healthy volunteers were acquired throughout the cardiac cycle using the spiral cine-DENSE pulse sequence gated to the R wave of an electrocardiogram. Pixelwise Lagrangian displacement maps were computed, and 2D displacement as a function of time was determined for selected regions of interests. Different intracranial structures exhibited characteristic motion amplitude, direction, and pattern throughout the cardiac cycle. Time-resolved displacement curves revealed the pathway of pulsatile motion from brain stem to peripheral brain lobes. These preliminary results demonstrated that the spiral cine-DENSE MRI technique can be used to measure cardiac-synchronized pulsatile brain motion on the pixel-by-pixel basis with high temporal∕spatial resolution and sensitivity. PMID:19746774
Coughlin, D J; Valdes, L; Rome, L C
1996-02-01
Recent attempts to determine how fish muscles are used to power swimming have employed the work loop technique (driving isolated muscles using their in vivo strain and stimulation pattern). These muscle strains have in turn been determined from the anatomical high-speed cine technique. In this study, we used an independent technique, sonomicrometry, to attempt to verify these strain measurements and the conclusions based on them. We found that the strain records measured from sonomicrometry and the anatomical-cine techniques were very similar. The ratio of the strain measured from sonomicrometry to that from the anatomical-cine technique was remarkably close to unity (1.046 +/- 0.013, mean +/- S.E.M., N = 15, for transducers placed on the muscle surface and corrected for muscle depth, and 0.921 +/- 0.028, N = 8, in cases where the transducers were inserted to the average depth of the red muscle). These measurements also showed that red muscle shortening occurs simultaneously with local backbone curvature, unlike previous results which suggested that white muscle shortening during the escape response occurs prior to the change in local backbone curvature.
SU-C-202-07: Protocol and Hardware for Improved Flood Field Calibration of TrueBeam FFF Cine Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adamson, J; Faught, A; Yin, F
2016-06-15
Purpose: Flattening filter free photon energies are commonly used for high dose treatments such as SBRT, where localization accuracy is essential. Often, MV cine imaging may be employed to verify correct localization. TrueBeam Electronic Portal Imaging Devices (EPIDs) equipped with the 40×30cm{sup 2} Image Detection Unit (IDU) are prone to image saturation at the image center especially for higher dose rates. While saturation often does not occur for cine imaging during treatment because the beam is attenuated by the patient, the flood field calibration is affected when the standard calibration procedure is followed. Here we describe the hardware and protocolmore » to achieve improved image quality for this model of TrueBeam EPID. Methods: A stainless steel filter of uniform thickness was designed to have sufficient attenuation to avoid panel saturation for both 6XFFF and 10XFFF at the maximum dose rates (1400 MU/min & 2400 MU/min, respectively). The cine imaging flood field calibration was then acquired with the filter in place for the FFF energies under the standard calibration geometry (SDD=150cm). Image quality during MV cine was assessed with & without the modified flood field calibration using a low contrast resolution phantom and an anthropomorphic phantom. Results: When the flood field is acquired using the standard procedure (no filter in place), a pixel gain artifact is clearly present in the image center (r=3cm for 10XFFF at 2400 MU/min) which appears similar to and may be mis-attributed to panel saturation in the subject image. The artifact obscured all low contrast inserts at the image center and was also visible on the anthropomorphic phantom. Using the filter for flood field calibration eliminated the artifact. Conclusion: Use of a modified flood field calibration procedure improves image quality for cine MV imaging with TrueBeams equipped with the 40×30cm{sup 2} IDU.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Guang, E-mail: lig2@mskcc.org; Wei, Jie; Kadbi, Mo
Purpose: To develop and evaluate a super-resolution approach to reconstruct time-resolved 4-dimensional magnetic resonance imaging (TR-4DMRI) with a high spatiotemporal resolution for multi-breathing cycle motion assessment. Methods and Materials: A super-resolution approach was developed to combine fast 3-dimensional (3D) cine MRI with low resolution during free breathing (FB) and high-resolution 3D static MRI during breath hold (BH) using deformable image registration. A T1-weighted, turbo field echo sequence, coronal 3D cine acquisition, partial Fourier approximation, and SENSitivity Encoding parallel acceleration were used. The same MRI pulse sequence, field of view, and acceleration techniques were applied in both FB and BH acquisitions;more » the intensity-based Demons deformable image registration method was used. Under an institutional review board–approved protocol, 7 volunteers were studied with 3D cine FB scan (voxel size: 5 × 5 × 5 mm{sup 3}) at 2 Hz for 40 seconds and a 3D static BH scan (2 × 2 × 2 mm{sup 3}). To examine the image fidelity of 3D cine and super-resolution TR-4DMRI, a mobile gel phantom with multi-internal targets was scanned at 3 speeds and compared with the 3D static image. Image similarity among 3D cine, 4DMRI, and 3D static was evaluated visually using difference image and quantitatively using voxel intensity correlation and Dice index (phantom only). Multi-breathing-cycle waveforms were extracted and compared in both phantom and volunteer images using the 3D cine as the references. Results: Mild imaging artifacts were found in the 3D cine and TR-4DMRI of the mobile gel phantom with a Dice index of >0.95. Among 7 volunteers, the super-resolution TR-4DMRI yielded high voxel-intensity correlation (0.92 ± 0.05) and low voxel-intensity difference (<0.05). The detected motion differences between TR-4DMRI and 3D cine were −0.2 ± 0.5 mm (phantom) and −0.2 ± 1.9 mm (diaphragms). Conclusion: Super-resolution TR-4DMRI has been reconstructed with adequate temporal (2 Hz) and spatial (2 × 2 × 2 mm{sup 3}) resolutions. Further TR-4DMRI characterization and improvement are necessary before clinical applications. Multi-breathing cycles can be examined, providing patient-specific breathing irregularities and motion statistics for future 4D radiation therapy.« less
Analysis of 3-D Tongue Motion from Tagged and Cine Magnetic Resonance Images
ERIC Educational Resources Information Center
Xing, Fangxu; Woo, Jonghye; Lee, Junghoon; Murano, Emi Z.; Stone, Maureen; Prince, Jerry L.
2016-01-01
Purpose: Measuring tongue deformation and internal muscle motion during speech has been a challenging task because the tongue deforms in 3 dimensions, contains interdigitated muscles, and is largely hidden within the vocal tract. In this article, a new method is proposed to analyze tagged and cine magnetic resonance images of the tongue during…
Copper-Catalyzed Heteroarylboration of 1,3-Dienes with 3-Bromopyridines: A cine Substitution.
Smith, Kevin B; Huang, Yuan; Brown, M Kevin
2018-04-26
A method for the heteroarylboration of 1,3-dienes is presented. The process involves an unusual cine substitution of 3-bromopyridine derivatives to deliver highly functionalized heterocyclic products. Mechanistic studies are included that clarify the details of this unusual process. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
3D Dose reconstruction: Banding artefacts in cine mode EPID images during VMAT delivery
NASA Astrophysics Data System (ADS)
Woodruff, H. C.; Greer, P. B.
2013-06-01
Cine (continuous) mode images obtained during VMAT delivery are heavily degraded by banding artefacts. We have developed a method to reconstruct the pulse sequence (and hence dose deposited) from open field images. For clinical VMAT fields we have devised a frame averaging strategy that greatly improves image quality and dosimetric information for three-dimensional dose reconstruction.
NASA Astrophysics Data System (ADS)
Mantilla, Juan; Garreau, Mireille; Bellanger, Jean-Jacques; Paredes, José Luis
2013-11-01
Assessment of the cardiac Left Ventricle (LV) wall motion is generally based on visual inspection or quantitative analysis of 2D+t sequences acquired in short-axis cardiac cine-Magnetic Resonance Imaging (MRI). Most often, cardiac dynamic is globally analized from two particular phases of the cardiac cycle. In this paper, we propose an automated method to classify regional wall motion in LV function based on spatio-temporal pro les and Support Vector Machines (SVM). This approach allows to obtain a binary classi cation between normal and abnormal motion, without the need of pre-processing and by exploiting all the images of the cardiac cycle. In each short- axis MRI slice level (basal, median, and apical), the spatio-temporal pro les are extracted from the selection of a subset of diametrical lines crossing opposites LV segments. Initialized at end-diastole phase, the pro les are concatenated with their corresponding projections into the succesive temporal phases of the cardiac cycle. These pro les are associated to di erent types of information that derive from the image (gray levels), Fourier, Wavelet or Curvelet domains. The approach has been tested on a set of 14 abnormal and 6 healthy patients by using a leave-one-out cross validation and two kernel functions for SVM classi er. The best classi cation performance is yielded by using four-level db4 wavelet transform and SVM with a linear kernel. At each slice level the results provided a classi cation rate of 87.14% in apical level, 95.48% in median level and 93.65% in basal level.
Joint multi-object registration and segmentation of left and right cardiac ventricles in 4D cine MRI
NASA Astrophysics Data System (ADS)
Ehrhardt, Jan; Kepp, Timo; Schmidt-Richberg, Alexander; Handels, Heinz
2014-03-01
The diagnosis of cardiac function based on cine MRI requires the segmentation of cardiac structures in the images, but the problem of automatic cardiac segmentation is still open, due to the imaging characteristics of cardiac MR images and the anatomical variability of the heart. In this paper, we present a variational framework for joint segmentation and registration of multiple structures of the heart. To enable the simultaneous segmentation and registration of multiple objects, a shape prior term is introduced into a region competition approach for multi-object level set segmentation. The proposed algorithm is applied for simultaneous segmentation of the myocardium as well as the left and right ventricular blood pool in short axis cine MRI images. Two experiments are performed: first, intra-patient 4D segmentation with a given initial segmentation for one time-point in a 4D sequence, and second, a multi-atlas segmentation strategy is applied to unseen patient data. Evaluation of segmentation accuracy is done by overlap coefficients and surface distances. An evaluation based on clinical 4D cine MRI images of 25 patients shows the benefit of the combined approach compared to sole registration and sole segmentation.
Orisaka, Makoto; Kurokawa, Tetsuji; Shukunami, Ken-Ichi; Orisaka, Sanae; Fukuda, Mika T; Shinagawa, Akiko; Fukuda, Shin; Ihara, Noboru; Yamada, Hiroki; Itoh, Harumi; Kotsuji, Fumikazu
2007-11-01
The non-pregnant uterus shows wave-like activity (uterine peristalsis). This pilot study was intended to determine: (1) whether uterine peristalsis during the menstrual cycle is detectable by cine magnetic resonance imaging (MRI); (2) the effects of leiomyoma on uterine peristalsis. Mid-sagittal MRI was performed sequentially with T2-weighted single-shot fast spin-echo (SSFSE) in 3 normal ovulatory volunteers and 19 premenopausal women with uterine leiomyoma. Direction and frequency of movement of the junctional zone were evaluated using a cine mode display. Junctional zone movement was identified in all subjects. Direction of uterine peristalsis in normal volunteers was fundus-to-cervix during menstruation, cervix-to-fundus during the periovulatory phase, and isthmical during the mid- and late-luteal phases. Abnormal peristaltic patterns were detected in three of five patients with uterine leiomyoma during menstruation and in the mid-luteal phase of the cycle, respectively. Cine MRI is a novel method for evaluation of uterine peristalsis. Results of this pilot study suggest that abnormal uterine peristalsis during menstruation and the mid-luteal phase might be one of the causes of hypermenorrhea and infertility associated with uterine leiomyoma.
Accelerating cine-MR Imaging in Mouse Hearts Using Compressed Sensing
Wech, Tobias; Lemke, Angela; Medway, Debra; Stork, Lee-Anne; Lygate, Craig A; Neubauer, Stefan; Köstler, Herbert; Schneider, Jürgen E
2011-01-01
Purpose To combine global cardiac function imaging with compressed sensing (CS) in order to reduce scan time and to validate this technique in normal mouse hearts and in a murine model of chronic myocardial infarction. Materials and Methods To determine the maximally achievable acceleration factor, fully acquired cine data, obtained in sham and chronically infarcted (MI) mouse hearts were 2–4-fold undersampled retrospectively, followed by CS reconstruction and blinded image segmentation. Subsequently, dedicated CS sampling schemes were implemented at a preclinical 9.4 T magnetic resonance imaging (MRI) system, and 2- and 3-fold undersampled cine data were acquired in normal mouse hearts with high temporal and spatial resolution. Results The retrospective analysis demonstrated that an undersampling factor of three is feasible without impairing accuracy of cardiac functional parameters. Dedicated CS sampling schemes applied prospectively to normal mouse hearts yielded comparable left-ventricular functional parameters, and intra- and interobserver variability between fully and 3-fold undersampled data. Conclusion This study introduces and validates an alternative means to speed up experimental cine-MRI without the need for expensive hardware. J. Magn. Reson. Imaging 2011. © 2011 Wiley Periodicals, Inc. PMID:21932360
WE-G-213CD-03: A Dual Complementary Verification Method for Dynamic Tumor Tracking on Vero SBRT.
Poels, K; Depuydt, T; Verellen, D; De Ridder, M
2012-06-01
to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondence model. The DT prototype software allowed the detailed logging of all applied gimbals rotations during tracking. The integration of an EPID on the vero system allowed the acquisition of cine EPID images during DT. We quantified the tracking error on cine EPID (E-EPID) by subtracting the target center (fiducial marker detection) and the field centroid. Dynamic gimbals log file information was combined with orthogonal x-ray verification images to calculate the in-vivo tracking error (E-kVLog). The correlation between E-kVLog and E-EPID was calculated for validation of the gimbals log file. Further, we investigated the sensitivity of the log file tracking error by introducing predefined systematic tracking errors. As an application we calculate gimbals log file tracking error for dynamic hidden target tests to investigate gravity effects and decoupled gimbals rotation from gantry rotation. Finally, calculating complementary cine EPID and log file tracking errors evaluated the clinical accuracy of dynamic tracking. A strong correlation was found between log file and cine EPID tracking error distribution during concurrent measurements (R=0.98). We found sensitivity in the gimbals log files to detect a systematic tracking error up to 0.5 mm. Dynamic hidden target tests showed no gravity influence on tracking performance and high degree of decoupled gimbals and gantry rotation during dynamic arc dynamic tracking. A submillimetric agreement between clinical complementary tracking error measurements was found. Redundancy of the internal gimbals log file with x-ray verification images with complementary independent cine EPID images was implemented to monitor the accuracy of gimballed tumor tracking on Vero SBRT. Research was financially supported by the Flemish government (FWO), Hercules Foundation and BrainLAB AG. © 2012 American Association of Physicists in Medicine.
Olivieri, Laura J; Cross, Russell R; O'Brien, Kendall E; Ratnayaka, Kanishka; Hansen, Michael S
2015-09-01
Cardiac magnetic resonance (MR) imaging is a valuable tool in congenital heart disease; however patients frequently have metal devices in the chest from the treatment of their disease that complicate imaging. Methods are needed to improve imaging around metal implants near the heart. Basic sequence parameter manipulations have the potential to minimize artifact while limiting effects on image resolution and quality. Our objective was to design cine and static cardiac imaging sequences to minimize metal artifact while maintaining image quality. Using systematic variation of standard imaging parameters on a fluid-filled phantom containing commonly used metal cardiac devices, we developed optimized sequences for steady-state free precession (SSFP), gradient recalled echo (GRE) cine imaging, and turbo spin-echo (TSE) black-blood imaging. We imaged 17 consecutive patients undergoing routine cardiac MR with 25 metal implants of various origins using both standard and optimized imaging protocols for a given slice position. We rated images for quality and metal artifact size by measuring metal artifact in two orthogonal planes within the image. All metal artifacts were reduced with optimized imaging. The average metal artifact reduction for the optimized SSFP cine was 1.5+/-1.8 mm, and for the optimized GRE cine the reduction was 4.6+/-4.5 mm (P < 0.05). Quality ratings favored the optimized GRE cine. Similarly, the average metal artifact reduction for the optimized TSE images was 1.6+/-1.7 mm (P < 0.05), and quality ratings favored the optimized TSE imaging. Imaging sequences tailored to minimize metal artifact are easily created by modifying basic sequence parameters, and images are superior to standard imaging sequences in both quality and artifact size. Specifically, for optimized cine imaging a GRE sequence should be used with settings that favor short echo time, i.e. flow compensation off, weak asymmetrical echo and a relatively high receiver bandwidth. For static black-blood imaging, a TSE sequence should be used with fat saturation turned off and high receiver bandwidth.
Korosoglou, Grigorios; Lossnitzer, Dirk; Schellberg, Dieter; Lewien, Antje; Wochele, Angela; Schaeufele, Tim; Neizel, Mirja; Steen, Henning; Giannitsis, Evangelos; Katus, Hugo A.; Osman, Nael F.
2009-01-01
Background High-dose dobutamine stress magnetic resonance imaging (DS-MRI) is safe and feasible for the diagnosis of coronary artery disease (CAD) in humans. However, the assessment of cine scans relies on the visual interpretation of regional wall motion, which is subjective. Recently, Strain-Encoded MRI (SENC) has been proposed for the direct color-coded visualization of myocardial strain. The purpose of our study was to compare the diagnostic value of SENC to that provided by conventional wall motion analysis for the detection of inducible ischemia during DS-MRI. Methods and Results Stress induced ischemia was assessed by wall motion analysis and by SENC in 101 patients with suspected or known CAD and in 17 healthy volunteers who underwent DS-MRI in a clinical 1.5T scanner. Quantitative coronary angiography deemed as the standard reference for the presence or absence of significant CAD (≥50% diameter stenosis). On a coronary vessel level, SENC detected inducible ischemia in 86/101 versus 71/101 diseased coronary vessels (p<0.01 versus cine), and showed normal strain response in 189/202 versus 194/202 vessels with <50% stenosis (p=NS versus cine). On a patient level, SENC detected inducible ischemia in 63/64 versus 55/64 patients with CAD (p<0.05 versus cine), and showed normal strain response in 32/37 versus 34/37 patients without CAD (p=NS versus cine).Quantification analysis demonstrated a significant correlation between strain rate reserve (SRreserve) and coronary artery stenosis severity (r²=0.56, p<0.001), and a cut-off value of SRreserve=1.64 deemed as a highly accurate marker for the detection of stenosis≥50% (AUC=0.96, SE=0.01, 95% CI = 0.94–0.98, p<0.001). Conclusions The direct color-coded visualization of strain on MR-images is a useful adjunct for DS-MRI, which provides incremental value for the detection of CAD compared to conventional wall motion readings on cine images. PMID:19808579
Korosoglou, Grigorios; Lossnitzer, Dirk; Schellberg, Dieter; Lewien, Antje; Wochele, Angela; Schaeufele, Tim; Neizel, Mirja; Steen, Henning; Giannitsis, Evangelos; Katus, Hugo A; Osman, Nael F
2009-03-01
High-dose dobutamine stress MRI is safe and feasible for the diagnosis of coronary artery disease (CAD) in humans. However, the assessment of cine scans relies on the visual interpretation of regional wall motion, which is subjective. Recently, strain-encoded MRI (SENC) has been proposed for the direct color-coded visualization of myocardial strain. The purpose of our study was to compare the diagnostic value of SENC with that provided by conventional wall motion analysis for the detection of inducible ischemia during dobutamine stress MRI. Stress-induced ischemia was assessed by wall motion analysis and by SENC in 101 patients with suspected or known CAD and in 17 healthy volunteers who underwent dobutamine stress MRI in a clinical 1.5-T scanner. Quantitative coronary angiography deemed as the standard reference for the presence or absence of significant CAD (> or =50% diameter stenosis). On a coronary vessel level, SENC detected inducible ischemia in 86 of 101 versus 71 of 101 diseased coronary vessels (P<0.01 versus cine) and showed normal strain response in 189 of 202 versus 194 of 202 vessels with <50% stenosis (P=NS versus cine). On a patient level, SENC detected inducible ischemia in 63 of 64 versus 55 of 64 patients with CAD (P<0.05 versus cine) and showed normal strain response in 32 of 37 versus 34 of 37 patients without CAD (P=NS versus cine). Quantification analysis demonstrated a significant correlation between strain rate reserve and coronary artery stenosis severity (r(2)=0.56, P<0.001), and a cutoff value of strain rate reserve of 1.64 was deemed as a highly accurate marker for the detection of > or =50% stenosis (area under the curve, 0.96; SE, 0.01; 95% CI, 0.94 to 0.98; P<0.001). The direct color-coded visualization of strain on MR images is a useful adjunct for dobutamine stress MRI, which provides incremental value for the detection of CAD compared with conventional wall motion readings on cine images.
Isn't it time to abandon cine film?
Holmes, D R; Wondrow, M A; Gray, J E
1990-05-01
Cine has served our needs well since the early 1950s. For the first time, it allowed recording of motion studies of the cardiac structures on film. The cine technique has been standardized over the years, both the camera and the display. Cine filming techniques, however, have not advanced, except for new film products with faster emulsions and better-quality films. Video electronic imaging has made rapid advancements. These were prompted by the broadcast industry when the requirements for color were developed in the 1960s and by the advent of new recording techniques that provided a very stable video time base from analog tape recorders. The medical field has been able to capitalize on these developments and to produce some of our own that have not been applied in the broadcast world. These include pulsed progressive 525-line video acquisition of cardiac images in the cardiac catheterization laboratory. We also have been able to capitalize on the improved detector technology that the broadcast world has developed, such as the plumbicon pickup tubes, which produce images with very little lag and so provide images with improved resolution. These developments also have enabled us to reduce radiation to both the patient and the laboratory personnel, especially with implementation of the pulsed progressive acquisition, with which the dose has been reduced 50%. With the advent of interventional procedures in the cardiac catheterization laboratory, the need to assess images immediately cannot be fulfilled by cine filming because of the requirement for the processing of the film with its inherent delays. Quantification of cardiac structures is required to assess the outcome of interventional techniques.(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Zhang, Dongqing; Icke, Ilknur; Dogdas, Belma; Parimal, Sarayu; Sampath, Smita; Forbes, Joseph; Bagchi, Ansuman; Chin, Chih-Liang; Chen, Antong
2018-03-01
In the development of treatments for cardiovascular diseases, short axis cardiac cine MRI is important for the assessment of various structural and functional properties of the heart. In short axis cardiac cine MRI, Cardiac properties including the ventricle dimensions, stroke volume, and ejection fraction can be extracted based on accurate segmentation of the left ventricle (LV) myocardium. One of the most advanced segmentation methods is based on fully convolutional neural networks (FCN) and can be successfully used to do segmentation in cardiac cine MRI slices. However, the temporal dependency between slices acquired at neighboring time points is not used. Here, based on our previously proposed FCN structure, we proposed a new algorithm to segment LV myocardium in porcine short axis cardiac cine MRI by incorporating convolutional long short-term memory (Conv-LSTM) to leverage the temporal dependency. In this approach, instead of processing each slice independently in a conventional CNN-based approach, the Conv-LSTM architecture captures the dynamics of cardiac motion over time. In a leave-one-out experiment on 8 porcine specimens (3,600 slices), the proposed approach was shown to be promising by achieving average mean Dice similarity coefficient (DSC) of 0.84, Hausdorff distance (HD) of 6.35 mm, and average perpendicular distance (APD) of 1.09 mm when compared with manual segmentations, which improved the performance of our previous FCN-based approach (average mean DSC=0.84, HD=6.78 mm, and APD=1.11 mm). Qualitatively, our model showed robustness against low image quality and complications in the surrounding anatomy due to its ability to capture the dynamics of cardiac motion.
Torigoe, Teruyuki; Ito, Katsuyoshi; Yamamoto, Akira; Kanki, Akihiko; Yasokawa, Kazuya; Tamada, Tsutomu; Yoshida, Koji
2014-05-01
The purpose of this study is to evaluate age-related changes in the secretory flow of pancreatic juice in the main pancreatic duct noninvasively by means of nonpharmacologic cine-dynamic MRCP using spatially selective inversion recovery (IR) pulse. Fifty-three subjects without a history of pancreatic disease were included. Four-second breath-hold MRCP using spatially selective IR pulse was performed every 15 seconds during 5 minutes (acquiring a total of 20 images) in cine-dynamic fashion. The secretion grade was classified into five grades by the distance of pancreatic juice inflow within the tagged area. The mean secretion grade and the frequency of secretion in cine-dynamic MRCP were compared among three age-range groups (group 1, < 40 years; group 2, 40-70 years; and group 3, > 70 years). Statistical analysis was performed using Spearman rank correlation coefficient and Kruskal-Wallis and Mann-Whitney U tests. The secretion grade and the frequency of secretion were significantly reduced with aging (r = -0.77, p < 0.001; and r = -0.74, p < 0.001, respectively). The mean secretion grade and the frequency of secretion were significantly lower in group 3 than in group 2 (mean grade, 0.36 vs 1.48, p = 0.001; and 4.8 vs 11.9 times, p = 0.001) and were lower in group 2 than in group 1 (mean grade, 1.48 vs 2.48, p < 0.001; and 11.9 vs 16.2 times, p = 0.011). Cine-dynamic MRCP using spatially selective IR pulse was able to show the age-related decrease of the secretory flow of pancreatic juice in the main pancreatic duct visually and noninvasively.
NASA Astrophysics Data System (ADS)
Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko
2017-02-01
A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were ⩽3 mm and ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases. This work was partly presented at the 58th Annual meeting of American Association of Physicists in Medicine.
Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko
2017-02-21
A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were ⩽3 mm and ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases.
Color characterization of cine film
NASA Astrophysics Data System (ADS)
Noriega, Leonardo; Morovic, Jan; MacDonald, Lindsay W.; Lempp, Wolfgang
2002-06-01
This paper describes the characterization of cine film, by identifying the relationship between the Status A density values of positive print film and the XYZ values of conventional colorimetry. Several approaches are tried including least-squares modeling, tetrahedral interpolation, and distance weighted interpolation. The distance weighted technique has been improved by the use of the Mahalanobis distance metric in order to perform the interpolation, and this is presented as an innovation.
NASA Astrophysics Data System (ADS)
Betancur, Julián.; Simon, Antoine; Schnell, Frédéric; Donal, Erwan; Hernández, Alfredo; Garreau, Mireille
2013-11-01
The acquisition of ECG-gated cine magnetic resonance images of the heart is routinely performed in apnea in order to suppress the motion artifacts caused by breathing. However, many factors including the 2D nature of the acquisition and the use of di erent beats to acquire the multiple-view cine images, cause this kind of artifacts to appear. This paper presents the qualitative evaluation of a method aiming to remove motion artifacts in multipleview cine images acquired on patients with hypertrophic cardiomyopathy diagnosis. The approach uses iconic registration to reduce for in-plane artifacts in long-axis-view image stacks and in-plane and out-of-plane motion artifacts in sort-axis-view image stack. Four similarity measures were evaluated: the normalized correlation, the normalized mutual information, the sum of absolute voxel di erences and the Slomka metric proposed by Slomka et al. The qualitative evaluation assessed the misalignment of di erent anatomical structures of the left ventricle as follows: the misalignment of the interventricular septum and the lateral wall for short-axis-view acquisitions and the misalignment between the short-axis-view image and long-axis-view images. Results showed the correction using the normalized correlation as the most appropriated with an 80% of success.
NASA Astrophysics Data System (ADS)
Lin, Jyh-Miin; Patterson, Andrew J.; Chao, Tzu-Cheng; Zhu, Chengcheng; Chang, Hing-Chiu; Mendes, Jason; Chung, Hsiao-Wen; Gillard, Jonathan H.; Graves, Martin J.
2017-05-01
The paper reports a free-breathing black-blood CINE fast-spin echo (FSE) technique for measuring abdominal aortic wall motion. The free-breathing CINE FSE includes the following MR techniques: (1) variable-density sampling with fast iterative reconstruction; (2) inner-volume imaging; and (3) a blood-suppression preparation pulse. The proposed technique was evaluated in eight healthy subjects. The inner-volume imaging significantly reduced the intraluminal artifacts of respiratory motion (p = 0.015). The quantitative measurements were a diameter of 16.3 ± 2.8 mm and wall distensibility of 2.0 ± 0.4 mm (12.5 ± 3.4%) and 0.7 ± 0.3 mm (4.1 ± 1.0%) for the anterior and posterior walls, respectively. The cyclic cross-sectional distensibility was 35 ± 15% greater in the systolic phase than in the diastolic phase. In conclusion, we developed a feasible CINE FSE method to measure the motion of the abdominal aortic wall, which will enable clinical scientists to study the elasticity of the abdominal aorta.
Recording high quality speech during tagged cine-MRI studies using a fiber optic microphone.
NessAiver, Moriel S; Stone, Maureen; Parthasarathy, Vijay; Kahana, Yuvi; Paritsky, Alexander; Paritsky, Alex
2006-01-01
To investigate the feasibility of obtaining high quality speech recordings during cine imaging of tongue movement using a fiber optic microphone. A Complementary Spatial Modulation of Magnetization (C-SPAMM) tagged cine sequence triggered by an electrocardiogram (ECG) simulator was used to image a volunteer while speaking the syllable pairs /a/-/u/, /i/-/u/, and the words "golly" and "Tamil" in sync with the imaging sequence. A noise-canceling, optical microphone was fastened approximately 1-2 inches above the mouth of the volunteer. The microphone was attached via optical fiber to a laptop computer, where the speech was sampled at 44.1 kHz. A reference recording of gradient activity with no speech was subtracted from target recordings. Good quality speech was discernible above the background gradient sound using the fiber optic microphone without reference subtraction. The audio waveform of gradient activity was extremely stable and reproducible. Subtraction of the reference gradient recording further reduced gradient noise by roughly 21 dB, resulting in exceptionally high quality speech waveforms. It is possible to obtain high quality speech recordings using an optical microphone even during exceptionally loud cine imaging sequences. This opens up the possibility of more elaborate MRI studies of speech including spectral analysis of the speech signal in all types of MRI.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mazur, Thomas R., E-mail: tmazur@radonc.wustl.edu, E-mail: hli@radonc.wustl.edu; Fischer-Valuck, Benjamin W.; Wang, Yuhe
Purpose: To first demonstrate the viability of applying an image processing technique for tracking regions on low-contrast cine-MR images acquired during image-guided radiation therapy, and then outline a scheme that uses tracking data for optimizing gating results in a patient-specific manner. Methods: A first-generation MR-IGRT system—treating patients since January 2014—integrates a 0.35 T MR scanner into an annular gantry consisting of three independent Co-60 sources. Obtaining adequate frame rates for capturing relevant patient motion across large fields-of-view currently requires coarse in-plane spatial resolution. This study initially (1) investigate the feasibility of rapidly tracking dense pixel correspondences across single, sagittal planemore » images (with both moderate signal-to-noise and spatial resolution) using a matching objective for highly descriptive vectors called scale-invariant feature transform (SIFT) descriptors associated to all pixels that describe intensity gradients in local regions around each pixel. To more accurately track features, (2) harmonic analysis was then applied to all pixel trajectories within a region-of-interest across a short training period. In particular, the procedure adjusts the motion of outlying trajectories whose relative spectral power within a frequency bandwidth consistent with respiration (or another form of periodic motion) does not exceed a threshold value that is manually specified following the training period. To evaluate the tracking reliability after applying this correction, conventional metrics—including Dice similarity coefficients (DSCs), mean tracking errors (MTEs), and Hausdorff distances (HD)—were used to compare target segmentations obtained via tracking to manually delineated segmentations. Upon confirming the viability of this descriptor-based procedure for reliably tracking features, the study (3) outlines a scheme for optimizing gating parameters—including relative target position and a tolerable margin about this position—derived from a probability density function that is constructed using tracking results obtained just prior to treatment. Results: The feasibility of applying the matching objective for SIFT descriptors toward pixel-by-pixel tracking on cine-MR acquisitions was first retrospectively demonstrated for 19 treatments (spanning various sites). Both with and without motion correction based on harmonic analysis, sub-pixel MTEs were obtained. A mean DSC value spanning all patients of 0.916 ± 0.001 was obtained without motion correction, with DSC values exceeding 0.85 for all patients considered. While most patients show accurate tracking without motion correction, harmonic analysis does yield substantial gain in accuracy (defined using HDs) for three particularly challenging subjects. An application of tracking toward a gating optimization procedure was then demonstrated that should allow a physician to balance beam-on time and tissue sparing in a patient-specific manner by tuning several intuitive parameters. Conclusions: Tracking results show high fidelity in assessing intrafractional motion observed on cine-MR acquisitions. Incorporating harmonic analysis during a training period improves the robustness of the tracking for challenging targets. The concomitant gating optimization procedure should allow for physicians to quantitatively assess gating effectiveness quickly just prior to treatment in a patient-specific manner.« less
Fast cine-magnetic resonance imaging point tracking for prostate cancer radiation therapy planning
NASA Astrophysics Data System (ADS)
Dowling, J.; Dang, K.; Fox, Chris D.; Chandra, S.; Gill, Suki; Kron, T.; Pham, D.; Foroudi, F.
2014-03-01
The analysis of intra-fraction organ motion is important for improving the precision of radiation therapy treatment delivery. One method to quantify this motion is for one or more observers to manually identify anatomic points of interest (POIs) on each slice of a cine-MRI sequence. However this is labour intensive and inter- and intra- observer variation can introduce uncertainty. In this paper a fast method for non-rigid registration based point tracking in cine-MRI sagittal and coronal series is described which identifies POIs in 0.98 seconds per sagittal slice and 1.35 seconds per coronal slice. The manual and automatic points were highly correlated (r>0.99, p<0.001) for all organs and the difference generally less than 1mm. For prostate planning peristalsis and rectal gas can result in unpredictable out of plane motion, suggesting the results may require manual verification.
Cine film replacement: digital archival requirements and remaining obstacles.
Holmes, D R; Wondrow, M A; Bell, M R; Nissen, S E; Cusma, J T
1998-07-01
The acceptance of the Digital Imaging and Communication in Medicine (DICOM) standard and the Compact Disk-Recordable (CD-R) as the interchange medium have been critical developments for laboratories that need to move forward on the cine replacement front, while at the same time retain a means to communicate with other centers. One remaining essential component which has not been satisfactorily addressed is the issue of how digital image data should be archived within an institution. Every laboratory must consider the diverse issues which affect the choice of a digital archiving system. These factors include technical and economic issues, along with the clinical routines prevailing in their laboratory. A complete understanding of the issues will lead to the formulation of multiple options which may prove acceptable and will help to overcome the last obstacle which remains for the complete replacement of cine film in the cardiac catheterization laboratory.
[The use of the "cine-technic" in the MRT diagnosis of the temporomandibular joint].
Vogl, T J; Eberhard, D; Weigl, P; Assal, J; Randzio, J
1992-03-01
A new cine-technique in a prospective study using rapid gradient echo sequences was evaluated for the MRT investigation of the temporo-mandibular joint. A newly developed hydraulic apparatus was used to produce progressive opening of the jaw and MRT appearances were recorded during predetermined points of mandibular movement. The investigation included 16 normals and 34 patients. A modified gradient echo sequence was combined with an optimised surface coil or a special double coil and this provided good spatial resolution of the articular disc and of the muscular and bony structure. Amongst the abnormal findings were luxation of the disc (15 cases), tears in the disc (5 cases), late effects of internal derangements (12 cases) and condylar hypermotility (7 cases). The new cine-technique provides specific images in any chosen position of the mandible depending on the clinical disability of the patient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, G; Tyagi, N; Deasy, J
2015-06-15
Purpose: Cine 2DMRI is useful in MR-guided radiotherapy but it lacks volumetric information. We explore the feasibility of estimating timeresolved (TR) 4DMRI based on cine 2DMRI and respiratory-correlated (RC) 4DMRI though simulation. Methods: We hypothesize that a volumetric image during free breathing can be approximated by interpolation among 3DMRI image sets generated from a RC-4DMRI. Two patients’ RC-4DMRI with 4 or 5 phases were used to generate additional 3DMRI by interpolation. For each patient, six libraries were created to have total 5-to-35 3DMRI images by 0–6 equi-spaced tri-linear interpolation between adjacent and full-inhalation/full-exhalation phases. Sagittal cine 2DMRI were generated frommore » reference 3DMRIs created from separate, unique interpolations from the original RC-4DMRI. To test if accurate 3DMRI could be generated through rigid registration of the cine 2DMRI to the 3DMRI libraries, each sagittal 2DMRI was registered to sagittal cuts in the same location in the 3DMRI within each library to identify the two best matches: one with greater lung volume and one with smaller. A final interpolation between the corresponding 3DMRI was then performed to produce the first-order-approximation (FOA) 3DMRI. The quality and performance of the FOA as a function of library size was assessed using both the difference in lung volume and average voxel intensity between the FOA and the reference 3DMRI. Results: The discrepancy between the FOA and reference 3DMRI decreases as the library size increases. The 3D lung volume difference decreases from 5–15% to 1–2% as the library size increases from 5 to 35 image sets. The average difference in lung voxel intensity decreases from 7–8 to 5–6 with the lung intensity being 0–135. Conclusion: This study indicates that the quality of FOA 3DMRI improves with increasing 3DMRI library size. On-going investigations will test this approach using actual cine 2DMRI and introduce a higher order approximation for improvements. This study is in part supported by NIH (U54CA137788 and U54CA132378)« less
Yeo, Inhwan Jason; Jung, Jae Won; Yi, Byong Yong; Kim, Jong Oh
2013-01-01
Purpose: When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated and scattered through target media. Thus, it may possess information about delivered radiation to the target. Using a continuous scan (cine) mode of EPID, which provides temporal dose images related to target and beam movements, the authors’ goal is to perform four-dimensional (4D) dose reconstruction. Methods: To evaluate this hypothesis, first, the authors have derived and subsequently validated a fast method of dose reconstruction based on virtual beamlet calculations of dose responses using a test intensity-modulated beam. This method was necessary for processing a large number of EPID images pertinent for four-dimensional reconstruction. Second, cine mode acquisition after summation over all images was validated through comparison with integration mode acquisition on EPID (IAS3 and aS1000) for the test beam. This was to confirm the agreement of the cine mode with the integrated mode, specifically for the test beam, which is an accepted mode of image acquisition for dosimetry with EPID. Third, in-phantom film and exit EPID dosimetry was performed on a moving platform using the same beam. Heterogeneous as well as homogeneous phantoms were used. The cine images were temporally sorted at 10% interval. The authors have performed dose reconstruction to the in-phantom plane from the sorted cine images using the above validated method of dose reconstruction. The reconstructed dose from each cine image was summed to compose a total reconstructed dose from the test beam delivery, and was compared with film measurements. Results: The new method of dose reconstruction was validated showing greater than 95.3% pass rates of the gamma test with the criteria of dose difference of 3% and distance to agreement of 3 mm. The dose comparison of the reconstructed dose with the measured dose for the two phantoms showed pass rates higher than 96.4% given the same criteria. Conclusions: Feasibility of 4D dose reconstruction was successfully demonstrated in this study. The 4D dose reconstruction demonstrated in this study can be a promising dose validation method for radiation delivery on moving organs. PMID:23635250
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, G; Zakian, K; Deasy, J
Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging.more » Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI. Further validation and improvement are still required prior to clinical applications. This study is in part supported by the NIH (U54CA137788/U54CA132378).« less
Tumour auto-contouring on 2d cine MRI for locally advanced lung cancer: A comparative study.
Fast, Martin F; Eiben, Björn; Menten, Martin J; Wetscherek, Andreas; Hawkes, David J; McClelland, Jamie R; Oelfke, Uwe
2017-12-01
Radiotherapy guidance based on magnetic resonance imaging (MRI) is currently becoming a clinical reality. Fast 2d cine MRI sequences are expected to increase the precision of radiation delivery by facilitating tumour delineation during treatment. This study compares four auto-contouring algorithms for the task of delineating the primary tumour in six locally advanced (LA) lung cancer patients. Twenty-two cine MRI sequences were acquired using either a balanced steady-state free precession or a spoiled gradient echo imaging technique. Contours derived by the auto-contouring algorithms were compared against manual reference contours. A selection of eight image data sets was also used to assess the inter-observer delineation uncertainty. Algorithmically derived contours agreed well with the manual reference contours (median Dice similarity index: ⩾0.91). Multi-template matching and deformable image registration performed significantly better than feature-driven registration and the pulse-coupled neural network (PCNN). Neither MRI sequence nor image orientation was a conclusive predictor for algorithmic performance. Motion significantly degraded the performance of the PCNN. The inter-observer variability was of the same order of magnitude as the algorithmic performance. Auto-contouring of tumours on cine MRI is feasible in LA lung cancer patients. Despite large variations in implementation complexity, the different algorithms all have relatively similar performance. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Vuissoz, Pierre-André; Odille, Freddy; Fernandez, Brice; Lohezic, Maelene; Benhadid, Adnane; Mandry, Damien; Felblinger, Jacques
2012-02-01
To assess cardiac function by means of a novel free-breathing cardiac magnetic resonance imaging (MRI) strategy. A stack of ungated 2D steady-state free precession (SSFP) slices was acquired during free breathing and reconstructed as cardiac cine imaging based on the generalized reconstruction by inversion of coupled systems (GRICS). A motion-compensated sliding window approach allows reconstructing cine movies with most motion artifacts cancelled. The proposed reconstruction uses prior knowledge from respiratory belts and electrocardiogram recordings and features a piecewise linear model that relates the electrocardiogram signal to cardiac displacements. The free-breathing protocol was validated in six subjects against a standard breath-held protocol. Image sharpness, as assessed by the image gradient entropy, was comparable to that of breath-held images and significantly better than in uncorrected images. Volumetric parameters of cardiac function in the left ventricle (LV) and right ventricle (RV) were similar, including end-systolic volumes, end-diastolic volumes and mass, stroke volumes, and ejection fractions (with differences of 3% ± 2.4 in the LV and 2.9% ± 4.4 in the RV). The duration of the free-breathing protocol was nearly the same as the breath-held protocol. Free-breathing cine-GRICS enables accurate assessment of volumetric parameters of cardiac function with efficient correction of motion. Copyright © 2011 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Osada, Masakazu; Tsukui, Hideki
2002-09-01
ABSTRACT Picture Archiving and Communication System (PACS) is a system which connects imaging modalities, image archives, and image workstations to reduce film handling cost and improve hospital workflow. Handling diagnostic ultrasound and endoscopy images is challenging, because it produces large amount of data such as motion (cine) images of 30 frames per second, 640 x 480 in resolution, with 24-bit color. Also, it requires enough image quality for clinical review. We have developed PACS which is able to manage ultrasound and endoscopy cine images with above resolution and frame rate, and investigate suitable compression method and compression rate for clinical image review. Results show that clinicians require capability for frame-by-frame forward and backward review of cine images because they carefully look through motion images to find certain color patterns which may appear in one frame. In order to satisfy this quality, we have chosen motion JPEG, installed and confirmed that we could capture this specific pattern. As for acceptable image compression rate, we have performed subjective evaluation. No subjects could tell the difference between original non-compressed images and 1:10 lossy compressed JPEG images. One subject could tell the difference between original and 1:20 lossy compressed JPEG images although it is acceptable. Thus, ratios of 1:10 to 1:20 are acceptable to reduce data amount and cost while maintaining quality for clinical review.
Paganelli, Chiara; Lee, Danny; Kipritidis, John; Whelan, Brendan; Greer, Peter B; Baroni, Guido; Riboldi, Marco; Keall, Paul
2018-02-11
In-room MRI is a promising image guidance strategy in external beam radiotherapy to acquire volumetric information for moving targets. However, limitations in spatio-temporal resolution led several authors to use 2D orthogonal images for guidance. The aim of this work is to present a method to concurrently compensate for non-rigid tumour motion and provide an approach for 3D reconstruction from 2D orthogonal cine-MRI slices for MRI-guided treatments. Free-breathing sagittal/coronal interleaved 2D cine-MRI were acquired in addition to a pre-treatment 3D volume in two patients. We performed deformable image registration (DIR) between cine-MRI slices and corresponding slices in the pre-treatment 3D volume. Based on an extrapolation of the interleaved 2D motion fields, the 3D motion field was estimated and used to warp the pre-treatment volume. Due to the lack of a ground truth for patients, the method was validated on a digital 4D lung phantom. On the phantom, the 3D reconstruction method was able to compensate for tumour motion and compared favourably to the results of previously adopted strategies. The difference in the 3D motion fields between the phantom and the extrapolated motion was 0.4 ± 0.3 mm for tumour and 0.8 ± 1.5 mm for whole anatomy, demonstrating feasibility of performing a 3D volumetric reconstruction directly from 2D orthogonal cine-MRI slices. Application of the method to patient data confirmed the feasibility of utilizing this method in real world scenarios. Preliminary results on phantom and patient cases confirm the feasibility of the proposed approach in an MRI-guided scenario, especially for non-rigid tumour motion compensation. © 2018 The Royal Australian and New Zealand College of Radiologists.
van Pelt, Roy; Nguyen, Huy; ter Haar Romeny, Bart; Vilanova, Anna
2012-03-01
Quantitative analysis of vascular blood flow, acquired by phase-contrast MRI, requires accurate segmentation of the vessel lumen. In clinical practice, 2D-cine velocity-encoded slices are inspected, and the lumen is segmented manually. However, segmentation of time-resolved volumetric blood-flow measurements is a tedious and time-consuming task requiring automation. Automated segmentation of large thoracic arteries, based solely on the 3D-cine phase-contrast MRI (PC-MRI) blood-flow data, was done. An active surface model, which is fast and topologically stable, was used. The active surface model requires an initial surface, approximating the desired segmentation. A method to generate this surface was developed based on a voxel-wise temporal maximum of blood-flow velocities. The active surface model balances forces, based on the surface structure and image features derived from the blood-flow data. The segmentation results were validated using volunteer studies, including time-resolved 3D and 2D blood-flow data. The segmented surface was intersected with a velocity-encoded PC-MRI slice, resulting in a cross-sectional contour of the lumen. These cross-sections were compared to reference contours that were manually delineated on high-resolution 2D-cine slices. The automated approach closely approximates the manual blood-flow segmentations, with error distances on the order of the voxel size. The initial surface provides a close approximation of the desired luminal geometry. This improves the convergence time of the active surface and facilitates parametrization. An active surface approach for vessel lumen segmentation was developed, suitable for quantitative analysis of 3D-cine PC-MRI blood-flow data. As opposed to prior thresholding and level-set approaches, the active surface model is topologically stable. A method to generate an initial approximate surface was developed, and various features that influence the segmentation model were evaluated. The active surface segmentation results were shown to closely approximate manual segmentations.
A novel technique for VMAT QA with EPID in cine mode on a Varian TrueBeam linac
NASA Astrophysics Data System (ADS)
Liu, Bo; Adamson, Justus; Rodrigues, Anna; Zhou, Fugen; Yin, Fang-fang; Wu, Qiuwen
2013-10-01
Volumetric modulated arc therapy (VMAT) is a relatively new treatment modality for dynamic photon radiation therapy. Pre-treatment quality assurance (QA) is necessary and many efforts have been made to apply electronic portal imaging device (EPID)-based IMRT QA methods to VMAT. It is important to verify the gantry rotation speed during delivery as this is a new variable that is also modulated in VMAT. In this paper, we present a new technique to perform VMAT QA using an EPID. The method utilizes EPID cine mode and was tested on Varian TrueBeam in research mode. The cine images were acquired during delivery and converted to dose matrices after profile correction and dose calibration. A sub-arc corresponding to each cine image was extracted from the original plan and its portal image prediction was calculated. Several analyses were performed including 3D γ analysis (2D images + gantry angle axis), 2D γ analysis, and other statistical analyses. The method was applied to 21 VMAT photon plans of 3 photon energies. The accuracy of the cine image information was investigated. Furthermore, this method's sensitivity to machine delivery errors was studied. The pass rate (92.8 ± 1.4%) for 3D γ analysis was comparable to those from Delta4 system (99.9 ± 0.1%) under similar criteria (3%, 3 mm, 5% threshold and 2° angle to agreement) at 6 MV. The recorded gantry angle and start/stop MUs were found to have sufficient accuracy for clinical QA. Machine delivery errors can be detected through combined analyses of 3D γ, gantry angle, and percentage dose difference. In summary, we have developed and validated a QA technique that can simultaneously verify the gantry angle and delivered MLC fluence for VMAT treatment.This technique is efficient and its accuracy is comparable to other QA methods.
Self-gated golden angle spiral cine MRI for coronary endothelial function assessment.
Bonanno, Gabriele; Hays, Allison G; Weiss, Robert G; Schär, Michael
2018-08-01
Depressed coronary endothelial function (CEF) is a marker for atherosclerotic disease, an independent predictor of cardiovascular events, and can be quantified non-invasively with ECG-triggered spiral cine MRI combined with isometric handgrip exercise (IHE). However, MRI-CEF measures can be hindered by faulty ECG-triggering, leading to prolonged breath-holds and degraded image quality. Here, a self-gated golden angle spiral method (SG-GA) is proposed to eliminate the need for ECG during cine MRI. SG-GA was tested against retrospectively ECG-gated golden angle spiral MRI (ECG-GA) and gold-standard ECG-triggered spiral cine MRI (ECG-STD) in 10 healthy volunteers. CEF data were obtained from cross-sectional images of the proximal right and left coronary arteries in a 3T scanner. Self-gating heart rates were compared to those from simultaneous ECG-gating. Coronary vessel sharpness and cross-sectional area (CSA) change with IHE were compared among the 3 methods. Self-gating precision, accuracy, and correlation-coefficient were 7.7 ± 0.5 ms, 9.1 ± 0.7 ms, and 0.93 ± 0.01, respectively (mean ± standard error). Vessel sharpness by SG-GA was equal or higher than ECG-STD (rest: 63.0 ± 1.7% vs. 61.3 ± 1.3%; exercise: 62.6 ± 1.3% vs. 56.7 ± 1.6%, P < 0.05). CSA changes were in agreement among the 3 methods (ECG-STD = 8.7 ± 4.0%, ECG-GA = 9.6 ± 3.1%, SG-GA = 9.1 ± 3.5%, P = not significant). CEF measures can be obtained with the proposed self-gated high-quality cine MRI method even when ECG is faulty or not available. Magn Reson Med 80:560-570, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Onishi, S; Fukui, S; Atsumi, C; Morita, R; Fujii, K; Kusuoka, H; Kitabatake, A; Kamada, T; Takizawa, O
1989-06-01
The clinical usefulness of magnetic resonance imaging (MRI) for evaluating regurgitant blood flow in patients with valvular heart disease was studied. The study subjects comprised three healthy volunteers and nine patients with valvular heart disease (aortic regurgitation 3, mitral regurgitation 2, tricuspid regurgitation 2, and pulmonary regurgitation 2). Five were men and seven were women, ranging in age from 31 to 85 years. Valvular heart disease was diagnosed by two-dimensional Doppler echocardiography. MRI was performed using a 1.5 tesla super-conductive magnet system (MAGNETOM, Siemens AG). A rapid MRI technique (fast low-angle shot [FLASH], flip angle = 30 degrees, TR = 65-90 msec, TE = 10-38 msec) was used to generate 11 frames throughout one cardiac cycle in the transaxial, coronal and oblique planes. These sequential frames were displayed in cine mode on a CRT. 1. Intracavitary blood was imaged as a high signal intensity on gradient echo images, while surrounding cardiac structures had somewhat lower signal intensities. 2. In healthy volunteers, systolic ejection blood flow from the left ventricle was observed on coronal images in the cine mode display. The influx of atrial blood into the left and right ventricles was also clearly observed on transaxial cine images. 3. Aortic regurgitant flow was observed as areas of no signal intensity within the left ventricular cavity during diastole on coronal images. 4. Mitral and tricuspid regurgitations were observed within the left and right atria, respectively, as areas of no signal intensity on transaxial images. The extent of regurgitant flow was determined in the vertical long-axis plane, equivalent to the right anterior oblique projection. 5. The vertical oblique scan was suitable for detecting pulmonary regurgitant flow. These results indicate that the rapid cine MRI technique is a useful tool for noninvasively determining regurgitant blood flow in patients with various valvular heart diseases.
NASA Astrophysics Data System (ADS)
Zamani, Pooria; Kayvanrad, Mohammad; Soltanian-Zadeh, Hamid
2012-12-01
This article presents a compressive sensing approach for reducing data acquisition time in cardiac cine magnetic resonance imaging (MRI). In cardiac cine MRI, several images are acquired throughout the cardiac cycle, each of which is reconstructed from the raw data acquired in the Fourier transform domain, traditionally called k-space. In the proposed approach, a majority, e.g., 62.5%, of the k-space lines (trajectories) are acquired at the odd time points and a minority, e.g., 37.5%, of the k-space lines are acquired at the even time points of the cardiac cycle. Optimal data acquisition at the even time points is learned from the data acquired at the odd time points. To this end, statistical features of the k-space data at the odd time points are clustered by fuzzy c-means and the results are considered as the states of Markov chains. The resulting data is used to train hidden Markov models and find their transition matrices. Then, the trajectories corresponding to transition matrices far from an identity matrix are selected for data acquisition. At the end, an iterative thresholding algorithm is used to reconstruct the images from the under-sampled k-space datasets. The proposed approaches for selecting the k-space trajectories and reconstructing the images generate more accurate images compared to alternative methods. The proposed under-sampling approach achieves an acceleration factor of 2 for cardiac cine MRI.
Unal, Ozkan; Kartum, Alp; Avcu, Serhat; Etlik, Omer; Arslan, Halil; Bora, Aydin
2009-12-01
The aim of this study was cerebrospinal flow quantification in the cerebral aqueduct using cine phase-contrast magnetic resonance imaging (MRI) technique in both sexes and five different age groups to provide normative data. Sixty subjects with no cerebral pathology were included in this study. Subjects were divided into five age groups: < or =14 years, 15-24 years, 25-34 years, 35-44 years, and > or =45 years. Phase, rephase, and magnitude images were acquired by 1.5 T MR unit at the level of cerebral aqueduct with spoiled gradient echo through-plane, which is a cine phase-contrast sequence. At this level, peak flow velocity (cm/s), average flow rate (cm/ s), average flow (L/min), volumes in cranial and caudal directions (mL), and net volumes (mL) were studied. There was a statistically significant difference in peak flow between the age group of < or =14 years and the older age groups. There were no statistically significant differences in average velocity, cranial and caudal volume, net volume, and average flow parameters among different age groups. Statistically significant differences were not detected in flow parameters between sexes. When using cine-phase contrast MRI in the cerebral aqueduct, only the peak velocity showed a statistically significant difference between age groups; it was higher in subjects aged < or =14 years than those in older age groups. When performing age-dependent clinical studies including adolescents, this should be taken into consideration.
Sotelo, Julio; Urbina, Jesús; Valverde, Israel; Mura, Joaquín; Tejos, Cristián; Irarrazaval, Pablo; Andia, Marcelo E; Hurtado, Daniel E; Uribe, Sergio
2018-01-01
We propose a 3D finite-element method for the quantification of vorticity and helicity density from 3D cine phase-contrast (PC) MRI. By using a 3D finite-element method, we seamlessly estimate velocity gradients in 3D. The robustness and convergence were analyzed using a combined Poiseuille and Lamb-Ossen equation. A computational fluid dynamics simulation was used to compared our method with others available in the literature. Additionally, we computed 3D maps for different 3D cine PC-MRI data sets: phantom without and with coarctation (18 healthy volunteers and 3 patients). We found a good agreement between our method and both the analytical solution of the combined Poiseuille and Lamb-Ossen. The computational fluid dynamics results showed that our method outperforms current approaches to estimate vorticity and helicity values. In the in silico model, we observed that for a tetrahedral element of 2 mm of characteristic length, we underestimated the vorticity in less than 5% with respect to the analytical solution. In patients, we found higher values of helicity density in comparison to healthy volunteers, associated with vortices in the lumen of the vessels. We proposed a novel method that provides entire 3D vorticity and helicity density maps, avoiding the used of reformatted 2D planes from 3D cine PC-MRI. Magn Reson Med 79:541-553, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Kobayashi, Naoharu; Lei, Jianxun; Utecht, Lynn; Garwood, Michael; Ingbar, David H.; Bhargava, Maneesh
2015-03-01
SWeep Imaging with Fourier Transformation (SWIFT) with gradient modulation and DC navigator retrospective gating is introduced as a 3D cine magnetic resonance imaging (MRI) method for the lung. In anesthetized normal rats, the quasi-simultaneous excitation and acquisition in SWIFT enabled extremely high sensitivity to the fast-decaying parenchymal signals (TE=~4 μs), which are invisible with conventional MRI techniques. Respiratory motion information was extracted from DC navigator signals and the SWIFT data were reconstructed to 3D cine images with 16 respiratory phases. To test this technique's capabilities, rats exposed to > 95% O2 for 60 hours for induction of acute respiratory distress syndrome (ARDS), were imaged and compared with normal rat lungs (N=7 and 5 for ARDS and normal groups, respectively). SWIFT images showed lung tissue density differences along the gravity direction. In the cine SWIFT images, a parenchymal signal drop at the inhalation phase was consistently observed for both normal and ARDS rats due to lung inflation (i.e. decrease of the proton density), but the drop was less for ARDS rats. Depending on the respiratory phase and lung region, the lungs from the ARDS rats showed 1-24% higher parenchymal signal intensities relative to the normal rat lungs, likely due to accumulated extravascular water (EVLW). Those results demonstrate that SWIFT has high enough sensitivity for detecting the lung proton density changes due to gravity, different phases of respiration and accumulation of EVLW in the rat ARDS lungs.
Validation of in vivo 2D displacements from spiral cine DENSE at 3T.
Wehner, Gregory J; Suever, Jonathan D; Haggerty, Christopher M; Jing, Linyuan; Powell, David K; Hamlet, Sean M; Grabau, Jonathan D; Mojsejenko, Walter Dimitri; Zhong, Xiaodong; Epstein, Frederick H; Fornwalt, Brandon K
2015-01-30
Displacement Encoding with Stimulated Echoes (DENSE) encodes displacement into the phase of the magnetic resonance signal. Due to the stimulated echo, the signal is inherently low and fades through the cardiac cycle. To compensate, a spiral acquisition has been used at 1.5T. This spiral sequence has not been validated at 3T, where the increased signal would be valuable, but field inhomogeneities may result in measurement errors. We hypothesized that spiral cine DENSE is valid at 3T and tested this hypothesis by measuring displacement errors at both 1.5T and 3T in vivo. Two-dimensional spiral cine DENSE and tagged imaging of the left ventricle were performed on ten healthy subjects at 3T and six healthy subjects at 1.5T. Intersection points were identified on tagged images near end-systole. Displacements from the DENSE images were used to project those points back to their origins. The deviation from a perfect grid was used as a measure of accuracy and quantified as root-mean-squared error. This measure was compared between 3T and 1.5T with the Wilcoxon rank sum test. Inter-observer variability of strains and torsion quantified by DENSE and agreement between DENSE and harmonic phase (HARP) were assessed by Bland-Altman analyses. The signal to noise ratio (SNR) at each cardiac phase was compared between 3T and 1.5T with the Wilcoxon rank sum test. The displacement accuracy of spiral cine DENSE was not different between 3T and 1.5T (1.2 ± 0.3 mm and 1.2 ± 0.4 mm, respectively). Both values were lower than the DENSE pixel spacing of 2.8 mm. There were no substantial differences in inter-observer variability of DENSE or agreement of DENSE and HARP between 3T and 1.5T. Relative to 1.5T, the SNR at 3T was greater by a factor of 1.4 ± 0.3. The spiral cine DENSE acquisition that has been used at 1.5T to measure cardiac displacements can be applied at 3T with equivalent accuracy. The inter-observer variability and agreement of DENSE-derived peak strains and torsion with HARP is also comparable at both field strengths. Future studies with spiral cine DENSE may take advantage of the additional SNR at 3T.
Kontaxis, C; Bol, G H; Stemkens, B; Glitzner, M; Prins, F M; Kerkmeijer, L G W; Lagendijk, J J W; Raaymakers, B W
2017-08-21
The hybrid MRI-radiotherapy machines, like the MR-linac (Elekta AB, Stockholm, Sweden) installed at the UMC Utrecht (Utrecht, The Netherlands), will be able to provide real-time patient imaging during treatment. In order to take advantage of the system's capabilities and enable online adaptive treatments, a new generation of software should be developed, ranging from motion estimation to treatment plan adaptation. In this work we present a proof of principle adaptive pipeline designed for high precision stereotactic body radiation therapy (SBRT) suitable for sites affected by respiratory motion, like renal cell carcinoma (RCC). We utilized our research MRL treatment planning system (MRLTP) to simulate a single fraction 25 Gy free-breathing SBRT treatment for RCC by performing inter-beam replanning for two patients and one volunteer. The simulated pipeline included a combination of (pre-beam) 4D-MRI and (online) 2D cine-MR acquisitions. The 4DMRI was used to generate the mid-position reference volume, while the cine-MRI, via an in-house motion model, provided three-dimensional (3D) deformable vector fields (DVFs) describing the anatomical changes during treatment. During the treatment fraction, at an inter-beam interval, the mid-position volume of the patient was updated and the delivered dose was accurately reconstructed on the underlying motion calculated by the model. Fast online replanning, targeting the latest anatomy and incorporating the previously delivered dose was then simulated with MRLTP. The adaptive treatment was compared to a conventional mid-position SBRT plan with a 3 mm planning target volume margin reconstructed on the same motion trace. We demonstrate that our system produced tighter dose distributions and thus spared the healthy tissue, while delivering more dose to the target. The pipeline was able to account for baseline variations/drifts that occurred during treatment ensuring target coverage at the end of the treatment fraction.
NASA Astrophysics Data System (ADS)
Kontaxis, C.; Bol, G. H.; Stemkens, B.; Glitzner, M.; Prins, F. M.; Kerkmeijer, L. G. W.; Lagendijk, J. J. W.; Raaymakers, B. W.
2017-09-01
The hybrid MRI-radiotherapy machines, like the MR-linac (Elekta AB, Stockholm, Sweden) installed at the UMC Utrecht (Utrecht, The Netherlands), will be able to provide real-time patient imaging during treatment. In order to take advantage of the system’s capabilities and enable online adaptive treatments, a new generation of software should be developed, ranging from motion estimation to treatment plan adaptation. In this work we present a proof of principle adaptive pipeline designed for high precision stereotactic body radiation therapy (SBRT) suitable for sites affected by respiratory motion, like renal cell carcinoma (RCC). We utilized our research MRL treatment planning system (MRLTP) to simulate a single fraction 25 Gy free-breathing SBRT treatment for RCC by performing inter-beam replanning for two patients and one volunteer. The simulated pipeline included a combination of (pre-beam) 4D-MRI and (online) 2D cine-MR acquisitions. The 4DMRI was used to generate the mid-position reference volume, while the cine-MRI, via an in-house motion model, provided three-dimensional (3D) deformable vector fields (DVFs) describing the anatomical changes during treatment. During the treatment fraction, at an inter-beam interval, the mid-position volume of the patient was updated and the delivered dose was accurately reconstructed on the underlying motion calculated by the model. Fast online replanning, targeting the latest anatomy and incorporating the previously delivered dose was then simulated with MRLTP. The adaptive treatment was compared to a conventional mid-position SBRT plan with a 3 mm planning target volume margin reconstructed on the same motion trace. We demonstrate that our system produced tighter dose distributions and thus spared the healthy tissue, while delivering more dose to the target. The pipeline was able to account for baseline variations/drifts that occurred during treatment ensuring target coverage at the end of the treatment fraction.
Aspheres for high speed cine lenses
NASA Astrophysics Data System (ADS)
Beder, Christian
2005-09-01
To fulfil the requirements of today's high performance cine lenses aspheres are an indispensable part of lens design. Among making them manageable in shape and size, tolerancing aspheres is an essential part of the development process. The traditional method of tolerancing individual aspherical coefficients results in unemployable theoretical figures only. In order to obtain viable parameters that can easily be dealt with in a production line, more enhanced techniques are required. In this presentation, a method of simulating characteristic manufacturing errors and deducing surface deviation and slope error tolerances will be shown.
[Evaluation of the invasion of esophageal cancer to the aorta by cine-MR imaging].
Kawahara, I; Nishimura, H; Uchida, M; Ueda, H; Fujimoto, K; Meno, S; Hayabuchi, N; Fujita, H
1993-01-25
We examined the usefulness of cine-MR imaging for evaluation of the invasion of esophageal cancer to the aorta in 12 cases. We used the technique of field echo pulse sequence. When the low intensity stripe was recognized between the tumor and the wall of aorta, we interpreted it as negative finding of the direct tumor invasion. By using this criteria, 11 of the 12 cases (92%) of the esophageal cancer for aortic wall invasion were correctly diagnosed as compared with 75% correct diagnosis by conventional MR imaging.
Vañó, Eliseo; Alejo, Luis; Ubeda, Carlos; Gutiérrez‐Larraya, Federico; Garayoa, Julia
2016-01-01
The aim of this study was to assess image quality and radiation dose of a biplane angiographic system with cone‐beam CT (CBCT) capability tuned for pediatric cardiac procedures. The results of this study can be used to explore dose reduction techniques. For pulsed fluoroscopy and cine modes, polymethyl methacrylate phantoms of various thicknesses and a Leeds TOR 18‐FG test object were employed. Various fields of view (FOV) were selected. For CBCT, the study employed head and body dose phantoms, Catphan 504, and an anthropomorphic cardiology phantom. The study also compared two 3D rotational angiography protocols. The entrance surface air kerma per frame increases by a factor of 3–12 when comparing cine and fluoroscopy frames. The biggest difference in the signal‐to‐noise ratio between fluoroscopy and cine modes occurs at FOV 32 cm because fluoroscopy is acquired at a 1440×1440 pixel matrix size and in unbinned mode, whereas cine is acquired at 720×720 pixels and in binned mode. The high‐contrast spatial resolution of cine is better than that of fluoroscopy, except for FOV 32 cm, because fluoroscopy mode with 32 cm FOV is unbinned. Acquiring CBCT series with a 16 cm head phantom using the standard dose protocol results in a threefold dose increase compared with the low‐dose protocol. Although the amount of noise present in the images acquired with the low‐dose protocol is much higher than that obtained with the standard mode, the images present better spatial resolution. A 1 mm diameter rod with 250 Hounsfield units can be distinguished in reconstructed images with an 8 mm slice width. Pediatric‐specific protocols provide lower doses while maintaining sufficient image quality. The system offers a novel 3D imaging mode. The acquisition of CBCT images results in increased doses administered to the patients, but also provides further diagnostic information contained in the volumetric images. The assessed CBCT protocols provide images that are noisy, but with very good spatial resolution. PACS number(s): 87.59.‐e, 87.59.‐C, 87.59.‐cf, 87.59.Dj, 87.57. uq PMID:27455474
Evolution of motion uncertainty in rectal cancer: implications for adaptive radiotherapy
NASA Astrophysics Data System (ADS)
Kleijnen, Jean-Paul J. E.; van Asselen, Bram; Burbach, Johannes P. M.; Intven, Martijn; Philippens, Marielle E. P.; Reerink, Onne; Lagendijk, Jan J. W.; Raaymakers, Bas W.
2016-01-01
Reduction of motion uncertainty by applying adaptive radiotherapy strategies depends largely on the temporal behavior of this motion. To fully optimize adaptive strategies, insight into target motion is needed. The purpose of this study was to analyze stability and evolution in time of motion uncertainty of both the gross tumor volume (GTV) and clinical target volume (CTV) for patients with rectal cancer. We scanned 16 patients daily during one week, on a 1.5 T MRI scanner in treatment position, prior to each radiotherapy fraction. Single slice sagittal cine MRIs were made at the beginning, middle, and end of each scan session, for one minute at 2 Hz temporal resolution. GTV and CTV motion were determined by registering a delineated reference frame to time-points later in time. The 95th percentile of observed motion (dist95%) was taken as a measure of motion. The stability of motion in time was evaluated within each cine-MRI separately. The evolution of motion was investigated between the reference frame and the cine-MRIs of a single scan session and between the reference frame and the cine-MRIs of several days later in the course of treatment. This observed motion was then converted into a PTV-margin estimate. Within a one minute cine-MRI scan, motion was found to be stable and small. Independent of the time-point within the scan session, the average dist95% remains below 3.6 mm and 2.3 mm for CTV and GTV, respectively 90% of the time. We found similar motion over time intervals from 18 min to 4 days. When reducing the time interval from 18 min to 1 min, a large reduction in motion uncertainty is observed. A reduction in motion uncertainty, and thus the PTV-margin estimate, of 71% and 75% for CTV and tumor was observed, respectively. Time intervals of 15 and 30 s yield no further reduction in motion uncertainty compared to a 1 min time interval.
NASA Astrophysics Data System (ADS)
Weiss, Robert M.; Otoadese, Eramosele A.; Oren, Ron M.
1995-05-01
The syndrome of constrictive pericarditis (CP) presents a diagnostic challenge to the clinician. This study was undertaken to determine whether cine computed tomography (CT), a cardiac imaging technique with excellent temporal and spatial resolution, can reliably demonstrate the unique abnormalities of pericardial anatomy and ventricular physiology present in patients with this condition. A second goal of this study was to determine whether the presence of diseased thickened pericardium, by itself, imparts cardiac impairment due to abnormalities of ventricular diastolic function. Methods: Twelve patients with CP suspected clinically, in whom invasive hemodynamic study was consistent with the diagnosis of CP, underwent cine CT. They were subdivided into Group 1 (CP, N equals 5) and Group 2 (No CP, N equals 7) based on histopathologic evaluation of tissue obtained at the time of surgery or autopsy. A third group consisted of asymptomatic patients with incidentally discovered thickened pericardium at the time of cine CT scanning: Group 3 (ThP, N equals 7). Group 4 (Nl, N equals 7) consisted of healthy volunteer subjects. Results: Pericardial thickness measurements with cine CT clearly distinguished Group 1 (mean equals 10 +/- 2 mm) from Group 2 (mean equals 2 +/- 1 mm), with diagnostic accuracy of 100% compared to histopathological findings. In addition, patients in Group 1 had significantly more brisk early diastolic filling of both left and right ventricles than those in Group 2, which clearly distinguished all patients with, from all patients without CP. Patients in Group 3 had pericardial thicknesses similar to those in Group 1 (mean equals 9 +/- 1 mm, p equals NS), but had patterns of diastolic ventricular filling that were nearly identical to Group 4 (Nl). Conclusions: The abnormalities of anatomy and ventricular function present in the syndrome of constrictive pericarditis are clearly and decisively identified by cine CT. This allows a reliable distinction between patients with constrictive pericarditis and those with cardiomyopathy. The presence of diseased thickened pericardium does not by itself impart impairment of ventricular diastolic function. Thus, definitive diagnosis of constrictive pericarditis requires demonstration of both abnormal anatomy and physiology.
Corredoira, Eva; Vañó, Eliseo; Alejo, Luis; Ubeda, Carlos; Gutiérrez-Larraya, Federico; Garayoa, Julia
2016-07-08
The aim of this study was to assess image quality and radiation dose of a biplane angiographic system with cone-beam CT (CBCT) capability tuned for pediatric cardiac procedures. The results of this study can be used to explore dose reduction techniques. For pulsed fluoroscopy and cine modes, polymethyl methacrylate phantoms of various thicknesses and a Leeds TOR 18-FG test object were employed. Various fields of view (FOV) were selected. For CBCT, the study employed head and body dose phantoms, Catphan 504, and an anthropomorphic cardiology phantom. The study also compared two 3D rotational angiography protocols. The entrance surface air kerma per frame increases by a factor of 3-12 when comparing cine and fluoroscopy frames. The biggest difference in the signal-to- noise ratio between fluoroscopy and cine modes occurs at FOV 32 cm because fluoroscopy is acquired at a 1440 × 1440 pixel matrix size and in unbinned mode, whereas cine is acquired at 720 × 720 pixels and in binned mode. The high-contrast spatial resolution of cine is better than that of fluoroscopy, except for FOV 32 cm, because fluoroscopy mode with 32 cm FOV is unbinned. Acquiring CBCT series with a 16 cm head phantom using the standard dose protocol results in a threefold dose increase compared with the low-dose protocol. Although the amount of noise present in the images acquired with the low-dose protocol is much higher than that obtained with the standard mode, the images present better spatial resolution. A 1 mm diameter rod with 250 Hounsfield units can be distinguished in reconstructed images with an 8 mm slice width. Pediatric-specific protocols provide lower doses while maintaining sufficient image quality. The system offers a novel 3D imaging mode. The acquisition of CBCT images results in increased doses administered to the patients, but also provides further diagnostic information contained in the volumetric images. The assessed CBCT protocols provide images that are noisy, but with very good spatial resolution. © 2016 The Authors.
NASA Astrophysics Data System (ADS)
Pollock, Sean; Kipritidis, John; Lee, Danny; Bernatowicz, Kinga; Keall, Paul
2016-09-01
Two interventions to overcome the deleterious impact irregular breathing has on thoracic-abdominal 4D computed tomography (4DCT) are (1) facilitating regular breathing using audiovisual biofeedback (AVB), and (2) prospective respiratory gating of the 4DCT scan based on the real-time respiratory motion. The purpose of this study was to compare the impact of AVB and gating on 4DCT imaging using the 4D eXtended cardiac torso (XCAT) phantom driven by patient breathing patterns. We obtained simultaneous measurements of chest and abdominal walls, thoracic diaphragm, and tumor motion from 6 lung cancer patients under two breathing conditions: (1) AVB, and (2) free breathing. The XCAT phantom was used to simulate 4DCT acquisitions in cine and respiratory gated modes. 4DCT image quality was quantified by artefact detection (NCCdiff), mean square error (MSE), and Dice similarity coefficient of lung and tumor volumes (DSClung, DSCtumor). 4DCT acquisition times and imaging dose were recorded. In cine mode, AVB improved NCCdiff, MSE, DSClung, and DSCtumor by 20% (p = 0.008), 23% (p < 0.001), 0.5% (p < 0.001), and 4.0% (p < 0.003), respectively. In respiratory gated mode, AVB improved NCCdiff, MSE, and DSClung by 29% (p < 0.001), 34% (p < 0.001), 0.4% (p < 0.001), respectively. AVB increased the cine acquisitions by 15 s and reduced respiratory gated acquisitions by 31 s. AVB increased imaging dose in cine mode by 10%. This was the first study to quantify the impact of breathing guidance and respiratory gating on 4DCT imaging. With the exception of DSCtumor in respiratory gated mode, AVB significantly improved 4DCT image analysis metrics in both cine and respiratory gated modes over free breathing. The results demonstrate that AVB and respiratory-gating can be beneficial interventions to improve 4DCT for cancer radiation therapy, with the biggest gains achieved when these interventions are used simultaneously.
Kato, Shingo; Kitagawa, Kakuya; Yoon, Yeonyee E; Nakajima, Hiroshi; Nagata, Motonori; Takase, Shinichi; Nakamori, Shiro; Ito, Masaaki; Sakuma, Hajime
2014-04-01
The purposes of this study were to evaluate the reproducibility for measuring the cold pressor test (CPT)-induced myocardial blood flow (MBF) alteration using phase-contrast (PC) cine MRI, and to determine if this approach could detect altered MBF response to CPT in smokers. After obtaining informed consent, ten healthy male non-smokers (mean age: 28±5 years) and ten age-matched male smokers (smoking duration ≥5 years, mean age: 28±3 years) were examined in this institutional review board approved study. Breath-hold PC cine MR images of the coronary sinus were obtained with a 3T MR imager with 32 channel coils at rest and during a CPT performed after immersing one foot in ice water. MBF was calculated as coronary sinus flow divided by the left ventricular (LV) mass which was given as a total LV myocardial volume measured on cine MRI multiplied by the specific gravity (1.05 g/mL). In non-smokers, MBF was 0.86±0.25 mL/min/g at rest, with a significant increase to 1.20±0.36 mL/min/g seen during CPT (percentage change of MBF (∆MBF (%)); 39.2%±14.4%, p<0.001). Inter-study reproducibility for ∆MBF (%) measurements by different MR technologist was good, as indicated by the intraclass correlation coefficient of 0.93 and reproducibility coefficient of 10.5%. There was no significant difference between smokers and non-smokers for resting MBF (0.85±0.32 mL/min/g, p=0.91). However, ∆MBF (%) in smokers was significantly reduced (-4.0±32.2% vs. 39.2±14.4%, p=0.011). PC cine MRI can be used to reproducibly quantify MBF response to CPT and to detect impaired flow response in smokers. This MR approach may be useful for monitoring the sequential change of coronary blood flow in various potentially pathologic conditions and for investigating its relationship with cardiovascular risk. Copyright © 2014 Elsevier Inc. All rights reserved.
SU-G-BRA-03: PCA Based Imaging Angle Optimization for 2D Cine MRI Based Radiotherapy Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, T; Yue, N; Jabbour, S
2016-06-15
Purpose: To develop an imaging angle optimization methodology for orthogonal 2D cine MRI based radiotherapy guidance using Principal Component Analysis (PCA) of target motion retrieved from 4DCT. Methods: We retrospectively analyzed 4DCT of 6 patients with lung tumor. A radiation oncologist manually contoured the target volume at the maximal inhalation phase of the respiratory cycle. An object constrained deformable image registration (DIR) method has been developed to track the target motion along the respiration at ten phases. The motion of the center of the target mass has been analyzed using the PCA to find out the principal motion components thatmore » were uncorrelated with each other. Two orthogonal image planes for cineMRI have been determined using this method to minimize the through plane motion during MRI based radiotherapy guidance. Results: 3D target respiratory motion for all 6 patients has been efficiently retrieved from 4DCT. In this process, the object constrained DIR demonstrated satisfactory accuracy and efficiency to enable the automatic motion tracking for clinical application. The average motion amplitude in the AP, lateral, and longitudinal directions were 3.6mm (min: 1.6mm, max: 5.6mm), 1.7mm (min: 0.6mm, max: 2.7mm), and 5.6mm (min: 1.8mm, max: 16.1mm), respectively. Based on PCA, the optimal orthogonal imaging planes were determined for cineMRI. The average angular difference between the PCA determined imaging planes and the traditional AP and lateral imaging planes were 47 and 31 degrees, respectively. After optimization, the average amplitude of through plane motion reduced from 3.6mm in AP images to 2.5mm (min:1.3mm, max:3.9mm); and from 1.7mm in lateral images to 0.6mm (min: 0.2mm, max:1.5mm), while the principal in plane motion amplitude increased from 5.6mm to 6.5mm (min: 2.8mm, max: 17mm). Conclusion: DIR and PCA can be used to optimize the orthogonal image planes of cineMRI to minimize the through plane motion during radiotherapy guidance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowshanfarzad, Pejman; Sabet, Mahsheed; O' Connor, Daryl J.
2011-07-15
Purpose:Verification of the mechanical isocenter position is required as part of comprehensive quality assurance programs for stereotactic radiosurgery/radiotherapy (SRS/SRT) treatments. Several techniques have been proposed for this purpose but each of them has certain drawbacks. In this paper, a new efficient and more comprehensive method using cine-EPID images has been introduced for automatic verification of the isocenter with sufficient accuracy for stereotactic applications. Methods: Using a circular collimator fixed to the gantry head to define the field, EPID images of a Winston-Lutz phantom were acquired in cine-imaging mode during 360 deg. gantry rotations. A robust matlab code was developed tomore » analyze the data by finding the center of the field and the center of the ball bearing shadow in each image with sub-pixel accuracy. The distance between these two centers was determined for every image. The method was evaluated by comparison to results of a mechanical pointer and also by detection of a manual shift applied to the phantom position. The repeatability and reproducibility of the method were tested and it was also applied to detect couch and collimator wobble during rotation. Results:The accuracy of the algorithm was 0.03 {+-} 0.02 mm. The repeatability was less than 3 {mu}m and the reproducibility was less than 86 {mu}m. The time elapsed for the analysis of more than 100 cine images of Varian aS1000 and aS500 EPIDs were {approx}65 and 20 s, respectively. Processing of images taken in integrated mode took 0.1 s. The output of the analysis software is printable and shows the isocenter shifts as a function of angle in both in-plane and cross-plane directions. It gives warning messages where the shifts exceed the criteria for SRS/SRT and provides useful data for the necessary adjustments in the system including bearing system and/or room lasers. Conclusions: The comprehensive method introduced in this study uses cine-images, is highly accurate, fast, and independent of the observer. It tests all gantry angles and is suitable for pretreatment QA of the isocenter for stereotactic treatments.« less
TU-F-CAMPUS-J-03: Evaluation of a New GE Device-Less Cine 4D-CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, R; Pan, T; Chandler, A
2015-06-15
Purpose: Standard cine 4D-CT (S-4DCT) is the cine CT scan of the thorax followed by image sorting with the respiratory signal recorded by the RPM. Although the feasibility of cine 4D-CT without RPM or device-less 4DCT (DL-4DCT) has been reported in a laboratory setting, the only commercial implementation of DL-4DCT was made recently by GE based on the measurements of the lung, body and air area and density. We report the initial results of this new DL-4DCT on its determination of gross tumor volume (GTV). Methods: 30 stereotactic body radiation therapy (SBRT) patients with NSCLC were included in the study.more » All patients received the S-4DCT for their treatment planning. Their cine CT data without the respiratory signal from RPM were submitted to the DL-4DCT. The DL-4DCT image quality was assessed in reference to S-4DCT. Using maximum intensity projection (MIP) images, the GTVs of the S-4DCT and DL-4DCT were compared on a subset of 9 patients whose tumors in the low density lung regions could be contoured using a region growing algorithm in MIM without contouring bias from the user. A lower threshold of −424 HU was used for all patients and other algorithm parameters were held constant for each patient. Results: The DL-4DCT was able to produce the 4DCT images on 29 out of the 30 SBRT cases. One case failed due to the enhanced calcification surrounding both the breast implants. The GTVs determined on the 9 patients with DL-4DCT were 4.2 ± 4.8% smaller than the GTVs with S-4DCT. However, this was statistically insignificant (p=0.15). The Dice similarity coefficients were 95.1 ± 1.8%. The image quality of DL-4DCT and S-4DCT was similar on the 29 cases. Conclusion: The first commercial DL-4DCT was promising in generating 4D-CT images without a respiratory monitoring device in this preliminary study of 30 patients.« less
Lorenz, C H; Walker, E S; Graham, T P; Powers, T A
1995-11-01
The long-term adaptation of the right ventricle after atrial repair of transposition of the great arteries (TGA) remains a subject of major concern. Cine magnetic resonance imaging (MRI), with its tomographic capabilities, allows unique quantitative evaluation of both right and left ventricular function and mass. Our purpose was to use MRI and an age-matched normal population to examine the typical late adaptation of the right and left ventricles after atrial repair of TGA. Cine MRI was used to study ventricular function and mass in 22 patients after atrial repair of TGA. Images were obtained in short-axis sections from base to apex to derive normalized right and left ventricular mass (RVM and LVM, g/m2), interventricular septal mass (IVSM, g/m2), RV and LV end-diastolic volumes (EDV, mL/m2), and ejection fractions (EF). Results 8 to 23 years after repair were compared with analysis of 24 age- and sex-matched normal volunteers and revealed markedly elevated RVM, decreased LVM and IVSM, normal RV size, and only mildly depressed RVEF. Only 1 of 22 patients had clinical RV dysfunction, and this patient had increased RVM. Cine MRI allows quantitative evaluation of both RV and LV mass and function late after atrial repair of TGA. Longitudinal studies that include these measurements should prove useful in determining the mechanism of late RV failure in these patients. On the basis of these early data, inadequate hypertrophy does not appear to be the cause of late dysfunction in this patient group.
NASA Astrophysics Data System (ADS)
Oswald, Helmut; Mueller-Jones, Kay; Builtjes, Jan; Fleck, Eckart
1998-07-01
The developments in information technologies -- computer hardware, networking and storage media -- has led to expectations that these advances make it possible to replace 35 mm film completely by digital techniques in the catheter laboratory. Besides the role of an archival medium, cine film is used as the major image review and exchange medium in cardiology. None of the today technologies can fulfill completely the requirements to replace cine film. One of the major drawbacks of cine film is the single access in time and location. For the four catheter laboratories in our institutions we have designed a complementary concept combining the CD-R, also called CD-medical, as a single patient storage and exchange medium, and a digital archive for on-line access and image review of selected frames or short sequences on adequate medical workstations. The image data from various modalities as well as all digital documents regarding to a patient are part of an electronic patient record. The access, the processing and the display of documents is supported by an integrated medical application.
Electrically stimulated contractions of Vorticella convallaria
NASA Astrophysics Data System (ADS)
Kantha, Deependra; van Winkle, David
2009-03-01
The contraction of Vorticella convallaria was triggered by applying a voltage pulse in its host culturing medium. The 50V, 1ms wide pulse was applied across platinum wires separated by 0.7 cm on a microscope slide. The contractions were recorded as cines (image sequences) by a Phantom V5 camera (Vision Research) on a bright field microscope with 20X objective, with the image size of 256 pixels x 128 pixels at 7352 pictures per second. The starting time of the cines was synchronized with the starting of the electrical pulse. We recorded five contractions of each of 12 organisms. The cines were analyzed to obtain the initiation time, defined as the difference in time between the leading edge of the electrical pulse and the first frame showing zooid movement. From multiple contractions of same organism, we found the initiation time is reproducible. In comparing different organisms, we found the average initiation time of 1.73 ms with a standard deviation of 0.63 ms. This research is supported by the state of Florida (MARTECH) and Research Corporation.
Multiple use of aspheres in cine lenses
NASA Astrophysics Data System (ADS)
Beder, Christian; Gängler, Dietmar
2008-09-01
Today's high performance cine lenses rely more and more on the use of aspheres. These are as powerful in correcting aberrations as they are expensive if it is not possible to use high-volume manufacturing processes. One possible solution to meet the increasing demands of design to cost is the use of identical parts in several lenses. The biggest gain is possible with the most expensive parts: the aspheres. In this presentation a successful as well as an ineffective way of incorporating the same asphere in three lenses which differ by a factor of 1.5 in focal length will be shown.
Cine CT technique for dynamic airway studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ell, S.R.; Jolles, H.; Keyes, W.D.
1985-07-01
The advent of cine CT scanning with its 50-msec data acquisition time promises a much wider range of dynamic CT studies. The authors describe a method for dynamic evaluation of the extrathoracic airway, which they believe has considerable potential application in nonfixed upper-airway disease, such as sleep apnea and stridor of unknown cause. Conventional CT is limited in such studies by long data acquisition time and can be used to study only prolonged maneuvers such as phonation. Fluoroscopy and digital subtraction studies are limited by relatively high radiation dose and inability to image all wall motions simultaneously.
Lloyd, David F.A.; Price, Anthony N.; Kuklisova Murgasova, Maria; Aljabar, Paul; Malik, Shaihan J.; Lohezic, Maelene; Rutherford, Mary A.; Pushparajah, Kuberan; Razavi, Reza; Hajnal, Joseph V.
2017-01-01
Purpose Development of a MRI acquisition and reconstruction strategy to depict fetal cardiac anatomy in the presence of maternal and fetal motion. Methods The proposed strategy involves i) acquisition and reconstruction of highly accelerated dynamic MRI, followed by image‐based ii) cardiac synchronization, iii) motion correction, iv) outlier rejection, and finally v) cardiac cine reconstruction. Postprocessing entirely was automated, aside from a user‐defined region of interest delineating the fetal heart. The method was evaluated in 30 mid‐ to late gestational age singleton pregnancies scanned without maternal breath‐hold. Results The combination of complementary acquisition/reconstruction and correction/rejection steps in the pipeline served to improve the quality of the reconstructed 2D cine images, resulting in increased visibility of small, dynamic anatomical features. Artifact‐free cine images successfully were produced in 36 of 39 acquired data sets; prolonged general fetal movements precluded processing of the remaining three data sets. Conclusions The proposed method shows promise as a motion‐tolerant framework to enable further detail in MRI studies of the fetal heart and great vessels. Processing data in image‐space allowed for spatial and temporal operations to be applied to the fetal heart in isolation, separate from extraneous changes elsewhere in the field of view. Magn Reson Med 79:327–338, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. PMID:28370252
Trotier, Aurélien J; Castets, Charles R; Lefrançois, William; Ribot, Emeline J; Franconi, Jean-Michel; Thiaudière, Eric; Miraux, Sylvain
2016-08-01
To develop and assess a 3D-cine self-gated method for cardiac imaging of murine models. A 3D stack-of-stars (SOS) short echo time (STE) sequence with a navigator echo was performed at 7T on healthy mice (n = 4) and mice with acute myocardial infarction (MI) (n = 4) injected with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. In all, 402 spokes were acquired per stack with the incremental or the golden angle method using an angle increment of (360/402)° or 222.48°, respectively. A cylindrical k-space was filled and repeated with a maximum number of repetitions (NR) of 10. 3D cine cardiac images at 156 μm resolution were reconstructed retrospectively and compared for the two methods in terms of contrast-to-noise ratio (CNR). The golden angle images were also reconstructed with NR = 10, 6, and 3, to assess cardiac functional parameters (ejection fraction, EF) on both animal models. The combination of 3D SOS-STE and USPIO injection allowed us to optimize the identification of cardiac peaks on navigator signal and generate high CNR between blood and myocardium (15.3 ± 1.0). The golden angle method resulted in a more homogeneous distribution of the spokes inside a stack (P < 0.05), enabling reducing the acquisition time to 15 minutes. EF was significantly different between healthy and MI mice (P < 0.05). The method proposed here showed that 3D-cine images could be obtained without electrocardiogram or respiratory gating in mice. It allows precise measurement of cardiac functional parameters even on MI mice. J. Magn. Reson. Imaging 2016;44:355-365. © 2016 Wiley Periodicals, Inc.
Furukawa, Akira; Yamamoto, Hiroshi; Ohta, Shinichi; Linh, Nguyen Dai Hung; Syerikjan, Tulyeubai; Kaida, Sachiko; Yamaguchi, Tsuyoshi; Murata, Satoshi; Obata, Toru; Tani, Masaji; Murata, Kiyoshi
2018-01-01
Dai-kenchu-to (TJ-100) is an herbal medicine used to shorten the duration of intestinal transit by accelerating intestinal movement. However, intestinal movement in itself has not been evaluated in healthy volunteers using radiography, fluoroscopy, and radioisotopes because of exposure to ionizing radiation. The purpose of this study was to evaluate the effect of TJ-100 on intestinal motility using cinematic magnetic resonance imaging (cine MRI) with a steady-state free precession sequence. Ten healthy male volunteers received 5 g of either TJ-100 or lactose without disclosure of the identity of the substance. Each volunteer underwent two MRI examinations after taking the substances (TJ-100 and lactose) on separate days. They drank 1200 mL of tap water and underwent cine MRI after 10 min. A steady-state free precession sequence was used for imaging, which was performed thrice at 0, 10, 20, 30, 40, and 50 min. The bowel contraction frequency and distention score were assessed. Wilcoxon signed-rank test was used, and differences were considered significant at a P-value <0.05. The bowel contraction frequency tended to be greater in the TJ-100 group and was significantly different in the ileum at 20 (TJ-100, 8.95 ± 2.88; lactose, 4.80 ± 2.92; P < 0.05) and 50 min (TJ-100, 9.45 ± 4.49; lactose, 4.45 ± 2.65; P < 0.05) between the groups. No significant differences were observed in the bowel distention scores. Cine MRI demonstrated that TJ-100 activated intestinal motility without dependence on ileum distention. PMID:29320574
Evaluation of lung tumor motion management in radiation therapy with dynamic MRI
NASA Astrophysics Data System (ADS)
Park, Seyoun; Farah, Rana; Shea, Steven M.; Tryggestad, Erik; Hales, Russell; Lee, Junghoon
2017-03-01
Surrogate-based tumor motion estimation and tracing methods are commonly used in radiotherapy despite the lack of continuous real time 3D tumor and surrogate data. In this study, we propose a method to simultaneously track the tumor and external surrogates with dynamic MRI, which allows us to evaluate their reproducible correlation. Four MRIcompatible fiducials are placed on the patient's chest and upper abdomen, and multi-slice 2D cine MRIs are acquired to capture the lung and whole tumor, followed by two-slice 2D cine MRIs to simultaneously track the tumor and fiducials, all in sagittal orientation. A phase-binned 4D-MRI is first reconstructed from multi-slice MR images using body area as a respiratory surrogate and group-wise registration. The 4D-MRI provides 3D template volumes for different breathing phases. 3D tumor position is calculated by 3D-2D template matching in which 3D tumor templates in 4D-MRI reconstruction and the 2D cine MRIs from the two-slice tracking dataset are registered. 3D trajectories of the external surrogates are derived via matching a 3D geometrical model to the fiducial segmentations on the 2D cine MRIs. We tested our method on five lung cancer patients. Internal target volume from 4D-CT showed average sensitivity of 86.5% compared to the actual tumor motion for 5 min. 3D tumor motion correlated with the external surrogate signal, but showed a noticeable phase mismatch. The 3D tumor trajectory showed significant cycle-to-cycle variation, while the external surrogate was not sensitive enough to capture such variations. Additionally, there was significant phase mismatch between surrogate signals obtained from fiducials at different locations.
Krishnamurthy, Rajesh; Pednekar, Amol; Atweh, Lamya A; Vogelius, Esben; Chu, Zili David; Zhang, Wei; Maskatia, Shiraz; Masand, Prakash; Morris, Shaine A; Krishnamurthy, Ramkumar; Muthupillai, Raja
2015-01-14
Cine balanced steady-state free precession (SSFP), the preferred sequence for ventricular function, demands uninterrupted radio frequency (RF) excitation to maintain the steady-state during suspended respiration. This is difficult to accomplish in sedated children. In this work, we validate a respiratory triggered (RT) SSFP sequence that drives the magnetization to steady-state before commencing retrospectively cardiac gated cine acquisition in a sedated pediatric population. This prospective study was performed on 20 sedated children with congenital heart disease (8.6 ± 4 yrs). Identical imaging parameters were used for multiple number of signal averages (MN) and RT cine SSFP sequences covering both the ventricles in short-axis (SA) orientation. Image quality assessment and quantitative volumetric analysis was performed on the datasets by two blinded observers. One-sided Wilcoxon signed rank test and Box plot analysis were performed to compare the clinical scores. Bland-Altman (BA) analysis was performed on LV and RV volumes. Scan duration for SA stack using RT-SSFP (3.9 ± 0.8 min) was slightly shorter than MN-SSFP (4.6 ± 0.9 min) acquisitions. The endocardial edge definition was significantly better for RT than MN, blood to myocardial contrast was better for RT than MN without reaching statistical significance, and inter slice alignment was comparable. BA analysis indicates that the variability of volumetric indices between RT and MN is comparable to inter and intra-observer variability reported in the literature. The free breathing RT-SSFP sequence allows diagnostic images in sedated children with significantly better edge definition when compared to MN-SSFP, without any penalty for total scan time.
Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; Abdul Aziz, Yang Faridah; Chee, Kok Han; McLaughlin, Robert A
2018-06-01
In this paper, we develop and validate an open source, fully automatic algorithm to localize the left ventricular (LV) blood pool centroid in short axis cardiac cine MR images, enabling follow-on automated LV segmentation algorithms. The algorithm comprises four steps: (i) quantify motion to determine an initial region of interest surrounding the heart, (ii) identify potential 2D objects of interest using an intensity-based segmentation, (iii) assess contraction/expansion, circularity, and proximity to lung tissue to score all objects of interest in terms of their likelihood of constituting part of the LV, and (iv) aggregate the objects into connected groups and construct the final LV blood pool volume and centroid. This algorithm was tested against 1140 datasets from the Kaggle Second Annual Data Science Bowl, as well as 45 datasets from the STACOM 2009 Cardiac MR Left Ventricle Segmentation Challenge. Correct LV localization was confirmed in 97.3% of the datasets. The mean absolute error between the gold standard and localization centroids was 2.8 to 4.7 mm, or 12 to 22% of the average endocardial radius. Graphical abstract Fully automated localization of the left ventricular blood pool in short axis cardiac cine MR images.
NASA Astrophysics Data System (ADS)
Dangi, Shusil; Linte, Cristian A.
2017-03-01
Segmentation of right ventricle from cardiac MRI images can be used to build pre-operative anatomical heart models to precisely identify regions of interest during minimally invasive therapy. Furthermore, many functional parameters of right heart such as right ventricular volume, ejection fraction, myocardial mass and thickness can also be assessed from the segmented images. To obtain an accurate and computationally efficient segmentation of right ventricle from cardiac cine MRI, we propose a segmentation algorithm formulated as an energy minimization problem in a graph. Shape prior obtained by propagating label from an average atlas using affine registration is incorporated into the graph framework to overcome problems in ill-defined image regions. The optimal segmentation corresponding to the labeling with minimum energy configuration of the graph is obtained via graph-cuts and is iteratively refined to produce the final right ventricle blood pool segmentation. We quantitatively compare the segmentation results obtained from our algorithm to the provided gold-standard expert manual segmentation for 16 cine-MRI datasets available through the MICCAI 2012 Cardiac MR Right Ventricle Segmentation Challenge according to several similarity metrics, including Dice coefficient, Jaccard coefficient, Hausdorff distance, and Mean absolute distance error.
Analysis of 3-D Tongue Motion From Tagged and Cine Magnetic Resonance Images
Woo, Jonghye; Lee, Junghoon; Murano, Emi Z.; Stone, Maureen; Prince, Jerry L.
2016-01-01
Purpose Measuring tongue deformation and internal muscle motion during speech has been a challenging task because the tongue deforms in 3 dimensions, contains interdigitated muscles, and is largely hidden within the vocal tract. In this article, a new method is proposed to analyze tagged and cine magnetic resonance images of the tongue during speech in order to estimate 3-dimensional tissue displacement and deformation over time. Method The method involves computing 2-dimensional motion components using a standard tag-processing method called harmonic phase, constructing superresolution tongue volumes using cine magnetic resonance images, segmenting the tongue region using a random-walker algorithm, and estimating 3-dimensional tongue motion using an incompressible deformation estimation algorithm. Results Evaluation of the method is presented with a control group and a group of people who had received a glossectomy carrying out a speech task. A 2-step principal-components analysis is then used to reveal the unique motion patterns of the subjects. Azimuth motion angles and motion on the mirrored hemi-tongues are analyzed. Conclusion Tests of the method with a various collection of subjects show its capability of capturing patient motion patterns and indicate its potential value in future speech studies. PMID:27295428
Haggerty, Christopher M; Kramer, Sage P; Binkley, Cassi M; Powell, David K; Mattingly, Andrea C; Charnigo, Richard; Epstein, Frederick H; Fornwalt, Brandon K
2013-08-27
Advanced measures of cardiac function are increasingly important to clinical assessment due to their superior diagnostic and predictive capabilities. Cine DENSE cardiovascular magnetic resonance (CMR) is ideal for quantifying advanced measures of cardiac function based on its high spatial resolution and streamlined post-processing. While many studies have utilized cine DENSE in both humans and small-animal models, the inter-test and inter-observer reproducibility for quantification of advanced cardiac function in mice has not been evaluated. This represents a critical knowledge gap for both understanding the capabilities of this technique and for the design of future experiments. We hypothesized that cine DENSE CMR would show excellent inter-test and inter-observer reproducibility for advanced measures of left ventricular (LV) function in mice. Five normal mice (C57BL/6) and four mice with depressed cardiac function (diet-induced obesity) were imaged twice, two days apart, on a 7T ClinScan MR system. Images were acquired with 15-20 frames per cardiac cycle in three short-axis (basal, mid, apical) and two long-axis orientations (4-chamber and 2-chamber). LV strain, twist, torsion, and measures of synchrony were quantified. Images from both days were analyzed by one observer to quantify inter-test reproducibility, while inter-observer reproducibility was assessed by a second observer's analysis of day-1 images. The coefficient of variation (CoV) was used to quantify reproducibility. LV strains and torsion were highly reproducible on both inter-observer and inter-test bases with CoVs ≤ 15%, and inter-observer reproducibility was generally better than inter-test reproducibility. However, end-systolic twist angles showed much higher variance, likely due to the sensitivity of slice location within the sharp longitudinal gradient in twist angle. Measures of synchrony including the circumferential (CURE) and radial (RURE) uniformity of strain indices, showed excellent reproducibility with CoVs of 1% and 3%, respectively. Finally, peak measures (e.g., strains) were generally more reproducible than the corresponding rates of change (e.g., strain rate). Cine DENSE CMR is a highly reproducible technique for quantification of advanced measures of left ventricular cardiac function in mice including strains, torsion and measures of synchrony. However, myocardial twist angles are not reproducible and future studies should instead report torsion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, H; Dolly, S; Anastasio, M
Purpose: In-treatment dynamic cine images, provided by the first commercially available MRI-guided radiotherapy system, allow physicians to observe intrafractional motion of head and neck (H&N) internal structures. Nevertheless, high anatomical complexity and relatively poor cine image contrast/resolution have complicated automatic intrafractional motion evaluation. We proposed an integrated model-based approach to automatically delineate and analyze moving structures from on-board cine images. Methods: The H&N upper airway, a complex and highly deformable region wherein severe internal motion often occurs, was selected as the target-to-be-tracked. To reliably capture its motion, a hierarchical structure model containing three statistical shapes (face, face-jaw, and face-jaw-palate) wasmore » first built from a set of manually delineated shapes using principal component analysis. An integrated model-fitting algorithm was then employed to align the statistical shapes to the first to-be-detected cine frame, and multi-feature level-set contour propagation was performed to identify the airway shape change in the remaining frames. Ninety sagittal cine MR image sets, acquired from three H&N cancer patients, were utilized to demonstrate this approach. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 20 randomly selected images from each patient. The resulting dice similarity coefficient (93.28+/−1.46 %) and margin error (0.49+/−0.12 mm) showed good agreement with the manual results. Intrafractional displacements of anterior, posterior, inferior, and superior airway boundaries were observed, with values of 2.62+/−2.92, 1.78+/−1.43, 3.51+/−3.99, and 0.68+/−0.89 mm, respectively. The H&N airway motion was found to vary across directions, fractions, and patients, and highly correlated with patients’ respiratory frequency. Conclusion: We proposed the integrated computational approach, which for the first time allows to automatically identify the H&N upper airway and quantify in-treatment H&N internal motion in real-time. This approach can be applied to track other structures’ motion, and provide guidance on patient-specific prediction of intra-/inter-fractional structure displacements.« less
Prowle, John R; Molan, Maurice P; Hornsey, Emma; Bellomo, Rinaldo
2012-06-01
In septic patients, decreased renal perfusion is considered to play a major role in the pathogenesis of acute kidney injury. However, the accurate measurement of renal blood flow in such patients is problematic and invasive. We sought to overcome such obstacles by measuring renal blood flow in septic patients with acute kidney injury using cine phase-contrast magnetic resonance imaging. Pilot observational study. University-affiliated general adult intensive care unit. Ten adult patients with established septic acute kidney injury and 11 normal volunteers. Cine phase-contrast magnetic resonance imaging measurement of renal blood flow and cardiac output. The median age of the study patients was 62.5 yrs and eight were male. At the time of magnetic resonance imaging, eight patients were mechanically ventilated, nine were on continuous hemofiltration, and five required vasopressors. Cine phase-contrast magnetic resonance imaging examinations were carried out without complication. Median renal blood flow was 482 mL/min (range 335-1137) in septic acute kidney injury and 1260 mL/min (range 791-1750) in healthy controls (p = .003). Renal blood flow indexed to body surface area was 244 mL/min/m2 (range 165-662) in septic acute kidney injury and 525 mL/min/m2 (range 438-869) in controls (p = .004). In patients with septic acute kidney injury, median cardiac index was 3.5 L/min/m2 (range 1.6-8.7), and median renal fraction of cardiac output was only 7.1% (range 4.4-10.8). There was no rank correlation between renal blood flow index and creatinine clearance in patients with septic acute kidney injury (r = .26, p = .45). Cine phase-contrast magnetic resonance imaging can be used to noninvasively and safely assess renal perfusion during critical illness in man. Near-simultaneous accurate measurement of cardiac output enables organ blood flow to be assessed in the context of the global circulation. Renal blood flow seems consistently reduced as a fraction of cardiac output in established septic acute kidney injury. Cine phase-contrast magnetic resonance imaging may be a valuable tool to further investigate renal blood flow and the effects of therapies on renal blood flow in critical illness.
A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Wendy; Ren, Lei, E-mail: lei.ren@duke.edu; Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina
Purpose: The purpose of this study was to develop a techique to generate on-board volumetric cine-magnetic resonance imaging (VC-MRI) using patient prior images, motion modeling, and on-board 2-dimensional cine MRI. Methods and Materials: One phase of a 4-dimensional MRI acquired during patient simulation is used as patient prior images. Three major respiratory deformation patterns of the patient are extracted from 4-dimensional MRI based on principal-component analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of themore » deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2-dimensional cine MRI. The method was evaluated using both digital extended-cardiac torso (XCAT) simulation of lung cancer patients and MRI data from 4 real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using volume-percent-difference (VPD), center-of-mass-shift (COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest (ROI) selection, patient breathing pattern change, and noise on the estimation accuracy were also evaluated. Results: Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between normalized profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was, on average, 8.43 ± 1.52% and the COMS was, on average, 0.93 ± 0.58 mm across all time steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR = 20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions: Preliminary studies demonstrated the feasibility of generating real-time VC-MRI for on-board localization of moving targets in radiation therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, W; Yin, F; Cai, J
Purpose: To develop a technique to generate on-board VC-MRI using patient prior 4D-MRI, motion modeling and on-board 2D-cine MRI for real-time 3D target verification of liver and lung radiotherapy. Methods: The end-expiration phase images of a 4D-MRI acquired during patient simulation are used as patient prior images. Principal component analysis (PCA) is used to extract 3 major respiratory deformation patterns from the Deformation Field Maps (DFMs) generated between end-expiration phase and all other phases. On-board 2D-cine MRI images are acquired in the axial view. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI atmore » the end-expiration phase. The DFM is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by matching the corresponding 2D slice of the estimated VC-MRI with the acquired single 2D-cine MRI. The method was evaluated using both XCAT (a computerized patient model) simulation of lung cancer patients and MRI data from a real liver cancer patient. The 3D-MRI at every phase except end-expiration phase was used to simulate the ground-truth on-board VC-MRI at different instances, and the center-tumor slice was selected to simulate the on-board 2D-cine images. Results: Image subtraction of ground truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground truth with prior image. Excellent agreement between profiles was achieved. The normalized cross correlation coefficients between the estimated and ground-truth in the axial, coronal and sagittal views for each time step were >= 0.982, 0.905, 0.961 for XCAT data and >= 0.998, 0.911, 0.9541 for patient data. For XCAT data, the maximum-Volume-Percent-Difference between ground-truth and estimated tumor volumes was 1.6% and the maximum-Center-of-Mass-Shift was 0.9 mm. Conclusion: Preliminary studies demonstrated the feasibility to estimate real-time VC-MRI for on-board target localization before or during radiotherapy treatments. National Institutes of Health Grant No. R01-CA184173; Varian Medical System.« less
Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy.
Gao, Hao; Zhang, Yawei; Ren, Lei; Yin, Fang-Fang
2018-01-01
This work aims to generate cine CT images (i.e., 4D images with high-temporal resolution) based on a novel principal component reconstruction (PCR) technique with motion learning from 2D fluoroscopic training images. In the proposed PCR method, the matrix factorization is utilized as an explicit low-rank regularization of 4D images that are represented as a product of spatial principal components and temporal motion coefficients. The key hypothesis of PCR is that temporal coefficients from 4D images can be reasonably approximated by temporal coefficients learned from 2D fluoroscopic training projections. For this purpose, we can acquire fluoroscopic training projections for a few breathing periods at fixed gantry angles that are free from geometric distortion due to gantry rotation, that is, fluoroscopy-based motion learning. Such training projections can provide an effective characterization of the breathing motion. The temporal coefficients can be extracted from these training projections and used as priors for PCR, even though principal components from training projections are certainly not the same for these 4D images to be reconstructed. For this purpose, training data are synchronized with reconstruction data using identical real-time breathing position intervals for projection binning. In terms of image reconstruction, with a priori temporal coefficients, the data fidelity for PCR changes from nonlinear to linear, and consequently, the PCR method is robust and can be solved efficiently. PCR is formulated as a convex optimization problem with the sum of linear data fidelity with respect to spatial principal components and spatiotemporal total variation regularization imposed on 4D image phases. The solution algorithm of PCR is developed based on alternating direction method of multipliers. The implementation is fully parallelized on GPU with NVIDIA CUDA toolbox and each reconstruction takes about a few minutes. The proposed PCR method is validated and compared with a state-of-art method, that is, PICCS, using both simulation and experimental data with the on-board cone-beam CT setting. The results demonstrated the feasibility of PCR for cine CBCT and significantly improved reconstruction quality of PCR from PICCS for cine CBCT. With a priori estimated temporal motion coefficients using fluoroscopic training projections, the PCR method can accurately reconstruct spatial principal components, and then generate cine CT images as a product of temporal motion coefficients and spatial principal components. © 2017 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Harris, Wendy; Yin, Fang-Fang; Wang, Chunhao; Zhang, You; Cai, Jing; Ren, Lei
2018-01-01
Purpose. To accelerate volumetric cine MRI (VC-MRI) using undersampled 2D-cine MRI to provide real-time 3D guidance for gating/target tracking in radiotherapy. Methods. 4D-MRI is acquired during patient simulation. One phase of the prior 4D-MRI is selected as the prior images, designated as MRIprior. The on-board VC-MRI at each time-step is considered a deformation of the MRIprior. The deformation field map is represented as a linear combination of the motion components extracted by principal component analysis from the prior 4D-MRI. The weighting coefficients of the motion components are solved by matching the corresponding 2D-slice of the VC-MRI with the on-board undersampled 2D-cine MRI acquired. Undersampled Cartesian and radial k-space acquisition strategies were investigated. The effects of k-space sampling percentage (SP) and distribution, tumor sizes and noise on the VC-MRI estimation were studied. The VC-MRI estimation was evaluated using XCAT simulation of lung cancer patients and data from liver cancer patients. Volume percent difference (VPD) and Center of Mass Shift (COMS) of the tumor volumes and tumor tracking errors were calculated. Results. For XCAT, VPD/COMS were 11.93 ± 2.37%/0.90 ± 0.27 mm and 11.53 ± 1.47%/0.85 ± 0.20 mm among all scenarios with Cartesian sampling (SP = 10%) and radial sampling (21 spokes, SP = 5.2%), respectively. When tumor size decreased, higher sampling rate achieved more accurate VC-MRI than lower sampling rate. VC-MRI was robust against noise levels up to SNR = 20. For patient data, the tumor tracking errors in superior-inferior, anterior-posterior and lateral (LAT) directions were 0.46 ± 0.20 mm, 0.56 ± 0.17 mm and 0.23 ± 0.16 mm, respectively, for Cartesian-based sampling with SP = 20% and 0.60 ± 0.19 mm, 0.56 ± 0.22 mm and 0.42 ± 0.15 mm, respectively, for radial-based sampling with SP = 8% (32 spokes). Conclusions. It is feasible to estimate VC-MRI from a single undersampled on-board 2D cine MRI. Phantom and patient studies showed that the temporal resolution of VC-MRI can potentially be improved by 5-10 times using a 2D cine image acquired with 10-20% k-space sampling.
Williams, Lynne K; Forero, Julian F; Popovic, Zoran B; Phelan, Dermot; Delgado, Diego; Rakowski, Harry; Wintersperger, Bernd J; Thavendiranathan, Paaladinesh
2017-08-07
Regional variability of longitudinal strain (LS) has been previously described with echocardiography in patients with cardiac amyloidosis (CA), however, the reason for this variability is not completely evident. We sought to describe regional patterns in LS using feature-tracking software applied to cardiovascular magnetic resonance (CMR) cine images in patients with CA, hypertrophic cardiomyopathy (HCM), and Anderson-Fabry's disease (AFD) and to relate these patterns to the distribution of late gadolinium enhancement (LGE). Patients with CA (n = 45) were compared to LV mass indexed matched patients with HCM (n = 19) and AFD (n = 19). Peak systolic LS measurements were obtained using Velocity Vector Imaging (VVI) software on CMR cine images. A relative regional LS ratio (RRSR) was calculated as the ratio of the average of the apical segmental LS divided by the sum of the average basal and mid-ventricular segmental LS. LGE was quantified for the basal, mid, and apical segments using a threshold of 5SD above remote myocardium. A regional LGE ratio was calculated similar to RRSR. Patients with CA had significantly had worse global LS (-15.7 ± 4.6%) than those with HCM (-18.0 ± 4.6%, p = 0.046) and AFD (-21.9 ± 5.1%, p < 0.001). The RRSR was higher in patients with CA (1.00 ± 0.31) than in AFD (0.79 ± 0.24; p = 0.018) but not HCM (0.84 ± 0.32; p = 0.114). In CA, a regional difference in LGE burden was noted, with lower LGE in the apex (31.5 ± 19.1%) compared to the mid (38.2 ± 19.0%) and basal (53.7 ± 22.7%; p < 0.001 for both) segments. The regional LGE ratio was not significantly different between patients with CA (0.33 ± 0.15) and AFD (0.47 ± 0.58; p = 0.14) but lower compared to those with HCM (0.72 ± 0.43; p < 0.0001). LGE percentage showed a significant impact on LS (p < 0.0001), with a 0.9% decrease in absolute LS for every 10% increase in LGE percentage. The presence of marked "relative apical sparing" of LS along with a significant reduction in global LS seen in patients with CA on CMR cine analysis may provide an additional tool to differentiate CA from other cause of LVH. The concomitant presence of a base to apex gradient in quantitative LGE burden suggests that the regional strain gradient may be at least partially explained by the burden of amyloid deposition and fibrosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kleijnen, J; Asselen, B van; Burbach, M
2015-06-15
Purpose: Purpose of this study is to find the optimal trade-off between adaptation interval and margin reduction and to define the implications of motion for rectal cancer boost radiotherapy on a MR-linac. Methods: Daily MRI scans were acquired of 16 patients, diagnosed with rectal cancer, prior to each radiotherapy fraction in one week (N=76). Each scan session consisted of T2-weighted and three 2D sagittal cine-MRI, at begin (t=0 min), middle (t=9:30 min) and end (t=18:00 min) of scan session, for 1 minute at 2 Hz temporal resolution. Tumor and clinical target volume (CTV) were delineated on each T2-weighted scan andmore » transferred to each cine-MRI. The start frame of the begin scan was used as reference and registered to frames at time-points 15, 30 and 60 seconds, 9:30 and 18:00 minutes and 1, 2, 3 and 4 days later. Per time-point, motion of delineated voxels was evaluated using the deformation vector fields of the registrations and the 95th percentile distance (dist95%) was calculated as measure of motion. Per time-point, the distance that includes 90% of all cases was taken as estimate of required planning target volume (PTV)-margin. Results: Highest motion reduction is observed going from 9:30 minutes to 60 seconds. We observe a reduction in margin estimates from 10.6 to 2.7 mm and 16.1 to 4.6 mm for tumor and CTV, respectively, when adapting every 60 seconds compared to not adapting treatment. A 75% and 71% reduction, respectively. Further reduction in adaptation time-interval yields only marginal motion reduction. For adaptation intervals longer than 18:00 minutes only small motion reductions are observed. Conclusion: The optimal adaptation interval for adaptive rectal cancer (boost) treatments on a MR-linac is 60 seconds. This results in substantial smaller PTV-margin estimates. Adaptation intervals of 18:00 minutes and higher, show little improvement in motion reduction.« less
A step-by-step solution for embedding user-controlled cines into educational Web pages.
Cornfeld, Daniel
2008-03-01
The objective of this article is to introduce a simple method for embedding user-controlled cines into a Web page using a simple JavaScript. Step-by-step instructions are included and the source code is made available. This technique allows the creation of portable Web pages that allow the user to scroll through cases as if seated at a PACS workstation. A simple JavaScript allows scrollable image stacks to be included on Web pages. With this technique, you can quickly and easily incorporate entire stacks of CT or MR images into online teaching files. This technique has the potential for use in case presentations, online didactics, teaching archives, and resident testing.
Kotani, Toshiaki; Akazawa, Tsutomu; Sakuma, Tsuyoshi; Nagaya, Shigeyuki; Sonoda, Masaru; Tanaka, Yuji; Katogi, Takehide; Nemoto, Tetsuharu; Minami, Shohei
2015-06-01
To investigate the effectiveness of incentive spirometry on respiratory motion in healthy subjects using cine breathing magnetic resonance imaging (MRI). Ten non-smoking healthy subjects without any history of respiratory disease were studied. Subjects were asked to perform pulmonary training using incentive spirometry every day for two weeks. To assess the effectiveness of this training, pulmonary function tests and cine breathing MRI were performed before starting pulmonary training and two weeks after its completion. After training, there were significant improvements in vital capacity (VC) from 3.58±0.8 L to 3.74±0.8 L and in %VC from 107.4±10.8 to 112.1±8.2. Significant changes were observed in the right diaphragm motion, right chest wall motion, and left chest wall motion, which were increased from 55.7±9.6 mm to 63.4±10.2 mm, from 15.6±6.1 mm to 23.4±10.4 mm, and from 16.3±7.6 mm to 22.0±9.8 mm, respectively. Two weeks of training using incentive spirometry provided improvements in pulmonary function and respiratory motion, which suggested that incentive spirometry may be a useful preoperative modality for improving pulmonary function during the perioperative period.
Schelhorn, Juliane; Neudorf, Ulrich; Schemuth, Haemi; Nensa, Felix; Nassenstein, Kai; Schlosser, Thomas W
2015-11-01
Patients with corrected tetralogy of Fallot (cToF) are prone to develop pulmonary regurgitation and right ventricular enlargement resulting in long-term complications, thus correct right ventricular volumetric monitoring is crucial. However, it remains controversial which cardiovascular magnetic resonance imaging (CMRI) slice orientation is most appropriate in cToF for the analysis of the right ventricular volume. To investigate which slice orientation is most suited for right ventricular volumetry in cToF we compared short-axis and axial slices, and furthermore we compared right ventricular data between CMRI and echocardiography. Thirty CMRI examinations of 27 patients with cToF were included retrospectively. Right ventricular end-diastolic (EDV) and end-systolic volume (ESV) were derived from short-axis and axial cine CMRI planes. Furthermore, pulmonary trunk forward flow in phase-contrast CMRI and right ventricular inner diastolic diameter in echocardiography (R VIDdiast) were measured. By Bland-Altman and variance analysis intra- and inter-observer agreement were assessed for cine CMRI data. By Pearson correlation CMRI cine and phase-contrast data and CMRI cine and echocardiographic data were compared. Intra- and inter-observer variability for right ventricular EDV were significantly lower in axial slices (P = 0.016, P = 0.010). For right ventricular ESV a trend towards a lower intra- and inter-observer variability in axial slices was found (P = 0.063, P = 0.138). Right ventricular stroke volume in short-axis (r = 0.872, P < 0.001) and in axial (r = 0.914, P < 0.001) planes correlated highly, respectively very highly with pulmonary trunk forward flow in phase-contrast CMRI. R VIDdiast correlated highly with right ventricular EDV assessed by short-axis and axial CMRI (P < 0.001, P < 0.001). Due to lower intra- and inter-observer variability, axial slices are recommended for right ventricular volumetry in cToF. © The Foundation Acta Radiologica 2014.
Piekarski, Eve; Chitiboi, Teodora; Ramb, Rebecca; Latson, Larry A; Bhatla, Puneet; Feng, Li; Axel, Leon
2017-01-01
Object Residual respiratory motion degrades image quality in conventional cardiac cine MRI (CCMR). We evaluated whether a free-breathing (FB) radial imaging CCMR sequence with compressed sensing reconstruction (eXtra-Dimension (e.g. cardiac and respiratory phases) Golden-angle RAdial Sparse Parallel, or XD-GRASP) could provide better image quality than a conventional Cartesian breath-held (BH) sequence, in an unselected population of patients undergoing clinical CCMR. Material and Methods 101 patients who underwent BH and FB imaging in a mid-ventricular short-axis plane at a matching location were included. Visual and quantitative image analysis was performed by two blinded experienced readers, using a 5-point qualitative scale to score overall image quality and visual signal-to-noise ratio (SNR) grade, with measures of noise and sharpness. End-diastole (ED) and end-systole (ES) left-ventricular areas were also measured and compared for both BH and FB images. Results Image quality was generally better with the BH cines (overall quality grade BH vs FB: 4 vs 2.9, p<0.001; noise 0.06 vs 0.08 p< 0.001; SNR grade: 4.1 vs 3, p<0.001), except for sharpness (p=0.48). There were no significant differences between BH and FB images regarding ED or ES areas (p=0.35 and 0.12). 18 of the 101 patients had impaired BH image quality (grades 1 or 2). In this subgroup, image quality of the FB images was better (p=0.0032), as was the SNR grade (p=0.003), but there were no significant differences regarding noise and sharpness (p=0.45, p=0.47). Conclusion Although FB XD-GRASP CCMR was visually inferior to conventional BH cardiac cine in general, it provided improved image quality in the subgroup of patients presenting respiratory motion-induced artifacts on breath-held images. PMID:29067539
Simultaneous tumor and surrogate motion tracking with dynamic MRI for radiation therapy planning
NASA Astrophysics Data System (ADS)
Park, Seyoun; Farah, Rana; Shea, Steven M.; Tryggestad, Erik; Hales, Russell; Lee, Junghoon
2018-01-01
Respiration-induced tumor motion is a major obstacle for achieving high-precision radiotherapy of cancers in the thoracic and abdominal regions. Surrogate-based estimation and tracking methods are commonly used in radiotherapy, but with limited understanding of quantified correlation to tumor motion. In this study, we propose a method to simultaneously track the lung tumor and external surrogates to evaluate their spatial correlation in a quantitative way using dynamic MRI, which allows real-time acquisition without ionizing radiation exposure. To capture the lung and whole tumor, four MRI-compatible fiducials are placed on the patient’s chest and upper abdomen. Two different types of acquisitions are performed in the sagittal orientation including multi-slice 2D cine MRIs to reconstruct 4D-MRI and two-slice 2D cine MRIs to simultaneously track the tumor and fiducials. A phase-binned 4D-MRI is first reconstructed from multi-slice MR images using body area as a respiratory surrogate and groupwise registration. The 4D-MRI provides 3D template volumes for different breathing phases. 3D tumor position is calculated by 3D-2D template matching in which 3D tumor templates in the 4D-MRI reconstruction and the 2D cine MRIs from the two-slice tracking dataset are registered. 3D trajectories of the external surrogates are derived via matching a 3D geometrical model of the fiducials to their segmentations on the 2D cine MRIs. We tested our method on ten lung cancer patients. Using a correlation analysis, the 3D tumor trajectory demonstrates a noticeable phase mismatch and significant cycle-to-cycle motion variation, while the external surrogate was not sensitive enough to capture such variations. Additionally, there was significant phase mismatch between surrogate signals obtained from the fiducials at different locations.
Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lever, Frederiek M.; Lips, Irene M.; Crijns, Sjoerd P.M.
2014-02-01
Purpose: To quantify the movement of esophageal tumors noninvasively on cine-magnetic resonance imaging (MRI) by use of a semiautomatic method to visualize tumor movement directly throughout multiple breathing cycles. Methods and Materials: Thirty-six patients with esophageal tumors underwent MRI. Tumors were located in the upper (8), middle (7), and lower (21) esophagus. Cine-MR images were collected in the coronal and sagittal plane during 60 seconds at a rate of 2 Hz. An adaptive correlation filter was used to automatically track a previously marked reference point. Tumor movement was measured in the craniocaudal (CC), left–right (LR), and anteroposterior (AP) directions andmore » its relationship along the longitudinal axis of the esophagus was investigated. Results: Tumor registration within the individual images was typically done at a millisecond time scale. The mean (SD) peak-to-peak displacements in the CC, AP, and LR directions were 13.3 (5.2) mm, 4.9 (2.5) mm, and 2.7 (1.2) mm, respectively. The bandwidth to cover 95% of excursions from the mean position (c95) was also calculated to exclude outliers caused by sporadic movements. The mean (SD) c95 values were 10.1 (3.8) mm, 3.7 (1.9) mm, and 2.0 (0.9) mm in the CC, AP, and LR dimensions. The end-exhale phase provided a stable position in the respiratory cycle, compared with more variety in the end-inhale phase. Furthermore, lower tumors showed more movement than did higher tumors in the CC and AP directions. Conclusions: Intrafraction tumor movement was highly variable between patients. Tumor position proved the most stable during the respiratory cycle in the end-exhale phase. A better understanding of tumor motion makes it possible to individualize radiation delivery strategies accordingly. Cine-MRI is a successful noninvasive modality to analyze motion for this purpose in the future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mazur, T; Wang, Y; Fischer-Valuck, B
2015-06-15
Purpose: To develop a novel and rapid, SIFT-based algorithm for assessing feature motion on cine MR images acquired during MRI-guided radiotherapy treatments. In particular, we apply SIFT descriptors toward both partitioning cine images into respiratory states and tracking regions across frames. Methods: Among a training set of images acquired during a fraction, we densely assign SIFT descriptors to pixels within the images. We cluster these descriptors across all frames in order to produce a dictionary of trackable features. Associating the best-matching descriptors at every frame among the training images to these features, we construct motion traces for the features. Wemore » use these traces to define respiratory bins for sorting images in order to facilitate robust pixel-by-pixel tracking. Instead of applying conventional methods for identifying pixel correspondences across frames we utilize a recently-developed algorithm that derives correspondences via a matching objective for SIFT descriptors. Results: We apply these methods to a collection of lung, abdominal, and breast patients. We evaluate the procedure for respiratory binning using target sites exhibiting high-amplitude motion among 20 lung and abdominal patients. In particular, we investigate whether these methods yield minimal variation between images within a bin by perturbing the resulting image distributions among bins. Moreover, we compare the motion between averaged images across respiratory states to 4DCT data for these patients. We evaluate the algorithm for obtaining pixel correspondences between frames by tracking contours among a set of breast patients. As an initial case, we track easily-identifiable edges of lumpectomy cavities that show minimal motion over treatment. Conclusions: These SIFT-based methods reliably extract motion information from cine MR images acquired during patient treatments. While we performed our analysis retrospectively, the algorithm lends itself to prospective motion assessment. Applications of these methods include motion assessment, identifying treatment windows for gating, and determining optimal margins for treatment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conroy, L; Quirk, S; Smith, WL
Purpose: We used Real-Time Position Management (RPM) to evaluate breath hold amplitude and variability when gating with a visually monitored deep inspiration breath hold technique (VM-DIBH) with retrospective cine image chest wall position verification. Methods: Ten patients with left-sided breast cancer were treated using VM-DIBH. Respiratory motion was passively collected once weekly using RPM with the marker block positioned at the xiphoid process. Cine images on the tangent medial field were acquired on fractions with RPM monitoring for retrospective verification of chest wall position during breath hold. The amplitude and duration of all breath holds on which treatment beams weremore » delivered were extracted from the RPM traces. Breath hold position coverage was evaluated for symmetric RPM gating windows from ± 1 to 5 mm centered on the average breath hold amplitude of the first measured fraction as a baseline. Results: The average (range) breath hold amplitude and duration was 18 mm (3–36 mm) and 19 s (7–34 s). The average (range) of amplitude standard deviation per patient over all breath holds was 2.7 mm (1.2–5.7 mm). With the largest allowable RPM gating window (± 5 mm), 4 of 10 VM-DIBH patients would have had ≥ 10% of their breath hold positions excluded by RPM. Cine verification of the chest wall position during the medial tangent field showed that the chest wall was greater than 5 mm from the baseline in only 1 out of 4 excluded patients. Cine images verify the chest wall/breast position only, whether this variation is acceptable in terms of heart sparing is a subject of future investigation. Conclusion: VM-DIBH allows for greater breath hold amplitude variability than using a 5 mm gating window with RPM, while maintaining chest wall positioning accuracy within 5 mm for the majority of patients.« less
Fukuyama, Atsushi; Isoda, Haruo; Morita, Kento; Mori, Marika; Watanabe, Tomoya; Ishiguro, Kenta; Komori, Yoshiaki; Kosugi, Takafumi
2017-01-01
Introduction: We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. Materials and Methods: The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 15, 12, 9, 6, and 3 mm). The pipes were fixed with 1% agarose containing 0.025 mol/L gadolinium contrast agent. A blood-mimicking fluid with human blood property values was circulated through the pipes at a steady flow. Magnetic resonance (MR) images (three-directional phase images with speed information and magnitude images for information of shape) were acquired using the 3-Tesla MR system and receiving coil. Temporal changes in spatially-averaged velocity and maximum velocity were calculated using hemodynamic analysis software. We calculated the error rates of the flow velocities based on the volume flow rates measured with a flowmeter and examined measurement accuracy. Results: When the acrylic pipe was the size of the thoracicoabdominal or cervical artery and the ratio of pixel size for the pipe was set at 30% or lower, spatially-averaged velocity measurements were highly accurate. When the pixel size ratio was set at 10% or lower, maximum velocity could be measured with high accuracy. It was difficult to accurately measure maximum velocity of the 3-mm pipe, which was the size of an intracranial major artery, but the error for spatially-averaged velocity was 20% or less. Conclusions: Flow velocity measurement accuracy of 3D cine PC MR imaging for pipes with inner sizes equivalent to vessels in the cervical and thoracicoabdominal arteries is good. The flow velocity accuracy for the pipe with a 3-mm-diameter that is equivalent to major intracranial arteries is poor for maximum velocity, but it is relatively good for spatially-averaged velocity. PMID:28132996
Epid cine acquisition mode for in vivo dosimetry in dynamic arc radiation therapy
NASA Astrophysics Data System (ADS)
Fidanzio, Andrea; Mameli, Alessandra; Placidi, Elisa; Greco, Francesca; Stimato, Gerardina; Gaudino, Diego; Ramella, Sara; D'Angelillo, Rolando; Cellini, Francesco; Trodella, Lucio; Cilla, Savino; Grimaldi, Luca; D'Onofrio, Guido; Azario, Luigi; Piermattei, Angelo
2008-02-01
In this paper the cine acquisition mode of an electronic portal imaging device (EPID) has been calibrated and tested to determine the in vivo dose for dynamic conformal arc radiation therapy (DCAT). The EPID cine acquisition mode, that allows a frame acquisition rate of one image every 1.66 s, was studied with a monitor unit rate equal to 100 UM/min. In these conditions good signal stability, ±1% (2SD) evaluated during three months, signal reproducibility within ±0.8% (2SD) and linearity with dose and dose rate within ±1% (2SD) were obtained. The transit signal, St, (due to the transmitted beam below the phantom) measured by the EPID cine acquisition mode was used to determine, (i) a set of correlation functions, F(w,L), defined as the ratio between St and the dose at half thickness, Dm, measured in solid water phantoms of different thicknesses, w and with square fields of side L, (ii) a set of factors, f(d,L), that take into account the different X-ray scatter contribution from the phantom to the St signal as a function of the variation, d, of the air gap between the phantom and the EPID. The reconstruction of the isocenter dose, Diso, for DCAT was obtained convolving the transit signal values, obtained at different gantry angles, with the respective reconstruction factors determined by a house-made software. The method was tested with cylindrical and anthropomorphic phantoms and the results show that the reconstructed Diso values can be obtained with an accuracy within ±2.5% in cylindrical phantom and within ±3.4% for anthropomorphic phantom. In conclusion, the transit dosimetry by EPID was assessed to be adequate to perform DCAT in vivo dosimetry, that is not realizable with the other traditional techniques. Moreover, the method proposed here could be implemented to supply in vivo dose values in real time.
Initial clinical observations of intra- and interfractional motion variation in MR-guided lung SBRT.
Thomas, David H; Santhanam, Anand; Kishan, Amar U; Cao, Minsong; Lamb, James; Min, Yugang; O'Connell, Dylan; Yang, Yingli; Agazaryan, Nzhde; Lee, Percy; Low, Daniel
2018-02-01
To evaluate variations in intra- and interfractional tumour motion, and the effect on internal target volume (ITV) contour accuracy, using deformable image registration of real-time two-dimensional-sagittal cine-mode MRI acquired during lung stereotactic body radiation therapy (SBRT) treatments. Five lung tumour patients underwent free-breathing SBRT treatments on the ViewRay system, with dose prescribed to a planning target volume (defined as a 3-6 mm expansion of the 4DCT-ITV). Sagittal slice cine-MR images (3.5 × 3.5 mm 2 pixels) were acquired through the centre of the tumour at 4 frames per second throughout the treatments (3-4 fractions of 21-32 min). Tumour gross tumour volumes (GTVs) were contoured on the first frame of the MR cine and tracked for the first 20 min of each treatment using offline optical-flow based deformable registration implemented on a GPU cluster. A ground truth ITV (MR-ITV 20 min ) was formed by taking the union of tracked GTV contours. Pseudo-ITVs were generated from unions of the GTV contours tracked over 10 s segments of image data (MR-ITV 10 s ). Differences were observed in the magnitude of median tumour displacement between days of treatments. MR-ITV 10 s areas were as small as 46% of the MR-ITV 20 min . An ITV offers a "snapshot" of breathing motion for the brief period of time the tumour is imaged on a specific day. Real-time MRI over prolonged periods of time and over multiple treatment fractions shows that ITV size varies. Further work is required to investigate the dosimetric effect of these results. Advances in knowledge: Five lung tumour patients underwent free-breathing MRI-guided SBRT treatments, and their tumours tracked using deformable registration of cine-mode MRI. The results indicate that variability of both intra- and interfractional breathing amplitude should be taken into account during planning of lung radiotherapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eccles, Cynthia L.; Patel, Ritesh; Simeonov, Anna K.
2011-02-01
Purpose: Abdominal compression (AC) can be used to reduce respiratory liver motion in patients undergoing liver stereotactic body radiotherapy. The purpose of the present study was to measure the changes in three-dimensional liver tumor motion with and without compression using cine-magnetic resonance imaging. Patients and Methods: A total of 60 patients treated as a part of an institutional research ethics board-approved liver stereotactic body radiotherapy protocol underwent cine T2-weighted magnetic resonance imaging through the tumor centroid in the coronal and sagittal planes. A total of 240 cine-magnetic resonance imaging sequences acquired at one to three images each second for 30-60more » s were evaluated using an in-house-developed template matching tool (based on the coefficient correlation) to measure the magnitude of the tumor motion. The average tumor edge displacements were used to determine the magnitude of changes in the caudal-cranial (CC) and anteroposterior (AP) directions, with and without AC. Results: The mean tumor motion without AC of 11.7 mm (range, 4.8-23.3) in the CC direction was reduced to 9.4 mm (range, 1.6-23.4) with AC. The tumor motion was reduced in both directions (CC and AP) in 52% of the patients and in a single direction (CC or AP) in 90% of the patients. The mean decrease in tumor motion with AC was 2.3 and 0.6 mm in the CC and AP direction, respectively. Increased motion occurred in one or more directions in 28% of patients. Clinically significant (>3 mm) decreases were observed in 40% and increases in <2% of patients in the CC direction. Conclusion: AC can significantly reduce three-dimensional liver tumor motion in most patients, although the magnitude of the reduction was smaller than previously reported.« less
CMR imaging of edema in myocardial infarction using cine balanced steady-state free precession.
Kumar, Andreas; Beohar, Nirat; Arumana, Jain Mangalathu; Larose, Eric; Li, Debiao; Friedrich, Matthias G; Dharmakumar, Rohan
2011-12-01
The aim of this study was to investigate the capabilities of balanced steady-state free precession (bSSFP) cardiac magnetic resonance imaging as a novel cine imaging approach for characterizing myocardial edema in animals and patients after reperfused myocardial infarction. Current cardiac magnetic resonance methods require 2 separate scans for assessment of myocardial edema and cardiac function. Mini-pigs (n = 13) with experimentally induced reperfused myocardial infarction and patients with reperfused ST-segment elevation myocardial infarction (n = 26) underwent cardiac magnetic resonance scans on days 2 to 4 post-reperfusion. Cine bSSFP, T2-weighted short TI inversion recovery (T2-STIR), and late gadolinium enhancement were performed at 1.5-T. Cine bSSFP and T2-STIR images were acquired with a body coil to mitigate surface coil bias. Signal, contrast, and the area of edema were compared. Additional patients (n = 10) were analyzed for the effect of microvascular obstruction on bSSFP. A receiver-operator characteristic analysis was performed to assess the accuracy of edema detection. An area of hyperintense bSSFP signal consistent with edema was observed in the infarction zone (contrast-to-noise ratio: 37 ± 13) in all animals and correlated well with the area of late gadolinium enhancement (R = 0.83, p < 0.01). In all patients, T2-STIR and bSSFP images showed regional hyperintensity in the infarction zone. Normalized contrast-to-noise ratios were not different between T2-STIR and bSSFP. On a slice basis, the volumes of hyperintensity on T2-STIR and bSSFP images correlated well (R = 0.86, p < 0.001), and their means were not different. When compared with T2-STIR, bSSFP was positive for edema in 25 of 26 patients (96% sensitivity) and was negative in all controls (100% specificity). All patients with microvascular obstruction showed a significant reduction of signal in the subendocardial infarction zone compared with infarcted epicardial tissue without microvascular obstruction (p < 0.05). Myocardial edema from ST-segment elevation myocardial infarction can be detected using cine bSSFP imaging with image contrast similar to T2-STIR. This new imaging approach allows evaluation of cardiac function and edema simultaneously, thereby reducing patient scan time and increasing efficiency. Further work is necessary to optimize edema contrast in bSSFP images. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Gadolinium-free MR in coarctation-can contrast-enhanced MR angiography be replaced?
Kalmar, Peter I; Koestenberger, Martin; Marterer, Robert; Tschauner, Sebastian; Sorantin, Erich
2016-01-01
To determine the difference in vessel measurements, signal-to-noise ratio (SNR), and voxel size between contrast-enhanced and noncontrast magnetic resonance techniques in patients with coarctation of the aorta (CoA). In 39 patients, vessel size, SNR, and voxel size were compared in cine magnetic resonance imaging (MRI), gadolinium-free magnetic resonance angiography (Gd-free MRA), and contrast-enhanced MRA (ce-MRA). There was no significant difference in measurement and SNR, but there was a significant difference in voxel size (P<.001). Our results show that, in CoA patients, monitoring of vessel size using cine MRI and Gd-free MRA is equivalent to ce-MRA while being less invasive. Copyright © 2016 Elsevier Inc. All rights reserved.
AFFINE-CORRECTED PARADISE: FREE-BREATHING PATIENT-ADAPTIVE CARDIAC MRI WITH SENSITIVITY ENCODING
Sharif, Behzad; Bresler, Yoram
2013-01-01
We propose a real-time cardiac imaging method with parallel MRI that allows for free breathing during imaging and does not require cardiac or respiratory gating. The method is based on the recently proposed PARADISE (Patient-Adaptive Reconstruction and Acquisition Dynamic Imaging with Sensitivity Encoding) scheme. The new acquisition method adapts the PARADISE k-t space sampling pattern according to an affine model of the respiratory motion. The reconstruction scheme involves multi-channel time-sequential imaging with time-varying channels. All model parameters are adapted to the imaged patient as part of the experiment and drive both data acquisition and cine reconstruction. Simulated cardiac MRI experiments using the realistic NCAT phantom show high quality cine reconstructions and robustness to modeling inaccuracies. PMID:24390159
CINE: Comet INfrared Excitation
NASA Astrophysics Data System (ADS)
de Val-Borro, Miguel; Cordiner, Martin A.; Milam, Stefanie N.; Charnley, Steven B.
2017-08-01
CINE calculates infrared pumping efficiencies that can be applied to the most common molecules found in cometary comae such as water, hydrogen cyanide or methanol. One of the main mechanisms for molecular excitation in comets is the fluorescence by the solar radiation followed by radiative decay to the ground vibrational state. This command-line tool calculates the effective pumping rates for rotational levels in the ground vibrational state scaled by the heliocentric distance of the comet. Fluorescence coefficients are useful for modeling rotational emission lines observed in cometary spectra at sub-millimeter wavelengths. Combined with computational methods to solve the radiative transfer equations based, e.g., on the Monte Carlo algorithm, this model can retrieve production rates and rotational temperatures from the observed emission spectrum.
Aminian, Farimah; Esmaeilzadeh, Maryam; Moladoust, Hassan; Maleki, Majid; Shahrzad, Soraya; Emkanjoo, Zahra; Sadeghpour, Anita
2014-08-01
The aim of this study was to determine the impact of manifest accessory pathway on left ventricle (LV) twist physiology in Wolff-Parkinson-White (WPW) patients. Although this issue was addressed in 1 study based on speckle tracking method, there was no comparative study with a different technique. We planned to use velocity vector imaging (VVI) to find out how much an accessory pathway can affect LV twist mechanics. Thirty patients were enrolled regarding inclusion and exclusion criteria. Two serial comprehensive transthoracic echocardiography evaluations were performed before and after radiofrequency catheter ablation (RFCA) within 24 hours. Stored cine loops were analyzed using VVI technique and LV twist and related parameters were extracted. Comparing pre- and post-RFCA data, no significant changes were observed in LV systolic and diastolic dimensions, LV ejection fraction (LVEF), and Doppler and tissue Doppler-related parameters. VVI study revealed remarkable rise in peak LV apical rotation (10.3º ± 3.0º to 13.8º ± 3.6º, P < 0.001) and basal rotation (-6.0 ± 1.8º to -7.7 ± 1.8º, P < 0.001) after RFCA. Subsequently LV twist showed a surge from 14.7º ± 3.9º to 20.2º ± 4.4º (P < 0.001). LV untwisting rate changed significantly from -96 ± 67 to -149.0 ± 47.5°/sec (P < 0.001) and apical-basal rotation delay showed a remarkable decline after RFCA (106 ± 81 vs. 42.8 ± 26.0 msec, P < 0.001). Accessory pathways have a major impact on LV twist mechanics. © 2013, Wiley Periodicals, Inc.
Dynamic flat panel detector versus image intensifier in cardiac imaging: dose and image quality
NASA Astrophysics Data System (ADS)
Vano, E.; Geiger, B.; Schreiner, A.; Back, C.; Beissel, J.
2005-12-01
The practical aspects of the dosimetric and imaging performance of a digital x-ray system for cardiology procedures were evaluated. The system was configured with an image intensifier (II) and later upgraded to a dynamic flat panel detector (FD). Entrance surface air kerma (ESAK) to phantoms of 16, 20, 24 and 28 cm of polymethyl methacrylate (PMMA) and the image quality of a test object were measured. Images were evaluated directly on the monitor and with numerical methods (noise and signal-to-noise ratio). Information contained in the DICOM header for dosimetry audit purposes was also tested. ESAK values per frame (or kerma rate) for the most commonly used cine and fluoroscopy modes for different PMMA thicknesses and for field sizes of 17 and 23 cm for II, and 20 and 25 cm for FD, produced similar results in the evaluated system with both technologies, ranging between 19 and 589 µGy/frame (cine) and 5 and 95 mGy min-1 (fluoroscopy). Image quality for these dose settings was better for the FD version. The 'study dosimetric report' is comprehensive, and its numerical content is sufficiently accurate. There is potential in the future to set those systems with dynamic FD to lower doses than are possible in the current II versions, especially for digital cine runs, or to benefit from improved image quality.
Akazawa, Tsutomu; Sakuma, Tsuyoshi; Nagaya, Shigeyuki; Sonoda, Masaru; Tanaka, Yuji; Katogi, Takehide; Nemoto, Tetsuharu; Minami, Shohei
2015-01-01
Objective To investigate the effectiveness of incentive spirometry on respiratory motion in healthy subjects using cine breathing magnetic resonance imaging (MRI). Methods Ten non-smoking healthy subjects without any history of respiratory disease were studied. Subjects were asked to perform pulmonary training using incentive spirometry every day for two weeks. To assess the effectiveness of this training, pulmonary function tests and cine breathing MRI were performed before starting pulmonary training and two weeks after its completion. Results After training, there were significant improvements in vital capacity (VC) from 3.58±0.8 L to 3.74±0.8 L and in %VC from 107.4±10.8 to 112.1±8.2. Significant changes were observed in the right diaphragm motion, right chest wall motion, and left chest wall motion, which were increased from 55.7±9.6 mm to 63.4±10.2 mm, from 15.6±6.1 mm to 23.4±10.4 mm, and from 16.3±7.6 mm to 22.0±9.8 mm, respectively. Conclusion Two weeks of training using incentive spirometry provided improvements in pulmonary function and respiratory motion, which suggested that incentive spirometry may be a useful preoperative modality for improving pulmonary function during the perioperative period. PMID:26161341
Wang, Lijia; Pei, Mengchao; Codella, Noel C F; Kochar, Minisha; Weinsaft, Jonathan W; Li, Jianqi; Prince, Martin R; Wang, Yi
2015-01-01
CMR quantification of LV chamber volumes typically and manually defines the basal-most LV, which adds processing time and user-dependence. This study developed an LV segmentation method that is fully automated based on the spatiotemporal continuity of the LV (LV-FAST). An iteratively decreasing threshold region growing approach was used first from the midventricle to the apex, until the LV area and shape discontinued, and then from midventricle to the base, until less than 50% of the myocardium circumference was observable. Region growth was constrained by LV spatiotemporal continuity to improve robustness of apical and basal segmentations. The LV-FAST method was compared with manual tracing on cardiac cine MRI data of 45 consecutive patients. Of the 45 patients, LV-FAST and manual selection identified the same apical slices at both ED and ES and the same basal slices at both ED and ES in 38, 38, 38, and 41 cases, respectively, and their measurements agreed within -1.6 ± 8.7 mL, -1.4 ± 7.8 mL, and 1.0 ± 5.8% for EDV, ESV, and EF, respectively. LV-FAST allowed LV volume-time course quantitatively measured within 3 seconds on a standard desktop computer, which is fast and accurate for processing the cine volumetric cardiac MRI data, and enables LV filling course quantification over the cardiac cycle.
Building and using a statistical 3D motion atlas for analyzing myocardial contraction in MRI
NASA Astrophysics Data System (ADS)
Rougon, Nicolas F.; Petitjean, Caroline; Preteux, Francoise J.
2004-05-01
We address the issue of modeling and quantifying myocardial contraction from 4D MR sequences, and present an unsupervised approach for building and using a statistical 3D motion atlas for the normal heart. This approach relies on a state-of-the-art variational non rigid registration (NRR) technique using generalized information measures, which allows for robust intra-subject motion estimation and inter-subject anatomical alignment. The atlas is built from a collection of jointly acquired tagged and cine MR exams in short- and long-axis views. Subject-specific non parametric motion estimates are first obtained by incremental NRR of tagged images onto the end-diastolic (ED) frame. Individual motion data are then transformed into the coordinate system of a reference subject using subject-to-reference mappings derived by NRR of cine ED images. Finally, principal component analysis of aligned motion data is performed for each cardiac phase, yielding a mean model and a set of eigenfields encoding kinematic ariability. The latter define an organ-dedicated hierarchical motion basis which enables parametric motion measurement from arbitrary tagged MR exams. To this end, the atlas is transformed into subject coordinates by reference-to-subject NRR of ED cine frames. Atlas-based motion estimation is then achieved by parametric NRR of tagged images onto the ED frame, yielding a compact description of myocardial contraction during diastole.
Velikina, Julia V; Samsonov, Alexey A
2015-11-01
To accelerate dynamic MR imaging through development of a novel image reconstruction technique using low-rank temporal signal models preestimated from training data. We introduce the model consistency condition (MOCCO) technique, which utilizes temporal models to regularize reconstruction without constraining the solution to be low-rank, as is performed in related techniques. This is achieved by using a data-driven model to design a transform for compressed sensing-type regularization. The enforcement of general compliance with the model without excessively penalizing deviating signal allows recovery of a full-rank solution. Our method was compared with a standard low-rank approach utilizing model-based dimensionality reduction in phantoms and patient examinations for time-resolved contrast-enhanced angiography (CE-MRA) and cardiac CINE imaging. We studied the sensitivity of all methods to rank reduction and temporal subspace modeling errors. MOCCO demonstrated reduced sensitivity to modeling errors compared with the standard approach. Full-rank MOCCO solutions showed significantly improved preservation of temporal fidelity and aliasing/noise suppression in highly accelerated CE-MRA (acceleration up to 27) and cardiac CINE (acceleration up to 15) data. MOCCO overcomes several important deficiencies of previously proposed methods based on pre-estimated temporal models and allows high quality image restoration from highly undersampled CE-MRA and cardiac CINE data. © 2014 Wiley Periodicals, Inc.
Velikina, Julia V.; Samsonov, Alexey A.
2014-01-01
Purpose To accelerate dynamic MR imaging through development of a novel image reconstruction technique using low-rank temporal signal models pre-estimated from training data. Theory We introduce the MOdel Consistency COndition (MOCCO) technique that utilizes temporal models to regularize the reconstruction without constraining the solution to be low-rank as performed in related techniques. This is achieved by using a data-driven model to design a transform for compressed sensing-type regularization. The enforcement of general compliance with the model without excessively penalizing deviating signal allows recovery of a full-rank solution. Methods Our method was compared to standard low-rank approach utilizing model-based dimensionality reduction in phantoms and patient examinations for time-resolved contrast-enhanced angiography (CE MRA) and cardiac CINE imaging. We studied sensitivity of all methods to rank-reduction and temporal subspace modeling errors. Results MOCCO demonstrated reduced sensitivity to modeling errors compared to the standard approach. Full-rank MOCCO solutions showed significantly improved preservation of temporal fidelity and aliasing/noise suppression in highly accelerated CE MRA (acceleration up to 27) and cardiac CINE (acceleration up to 15) data. Conclusions MOCCO overcomes several important deficiencies of previously proposed methods based on pre-estimated temporal models and allows high quality image restoration from highly undersampled CE-MRA and cardiac CINE data. PMID:25399724
Novel imaging detailing the origins of a pneumothorax.
Nakanishi, Kozo; Goto, Hidenori; Ito, Tomokazu; Nagata, Yasuhito; Hayashi, Shinichi; Ishihara, Toshihiro
2018-01-01
This is a prospective clinical study aimed at introducing a method to visualise the location of an air leak and to identify the bulla responsible on three-dimensional (3-D) cine CT. In 10 patients with spontaneous pneumothorax, dynamic 320-detector row CT was performed with injection of 0.9% saline into the affected pleural cavity via a preplaced chest tube. In eight cases, 3-D cine CT thoracography revealed the location of the air leak and the bulla responsible (7 cases: air stream sign; 1 case: repeated collapse and expansion of a bulla with the patient's breathing). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Validating a new methodology for strain estimation from cardiac cine MRI
NASA Astrophysics Data System (ADS)
Elnakib, Ahmed; Beache, Garth M.; Gimel'farb, Georgy; Inanc, Tamer; El-Baz, Ayman
2013-10-01
This paper focuses on validating a novel framework for estimating the functional strain from cine cardiac magnetic resonance imaging (CMRI). The framework consists of three processing steps. First, the left ventricle (LV) wall borders are segmented using a level-set based deformable model. Second, the points on the wall borders are tracked during the cardiac cycle based on solving the Laplace equation between the LV edges. Finally, the circumferential and radial strains are estimated at the inner, mid-wall, and outer borders of the LV wall. The proposed framework is validated using synthetic phantoms of the material strains that account for the physiological features and the LV response during the cardiac cycle. Experimental results on simulated phantom images confirm the accuracy and robustness of our method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Jihyung; Jung, Jae Won, E-mail: jungj@ecu.ed
Purpose: A method is proposed to reconstruct a four-dimensional (4D) dose distribution using phase matching of measured cine images to precalculated images of electronic portal imaging device (EPID). Methods: (1) A phantom, designed to simulate a tumor in lung (a polystyrene block with a 3 cm diameter embedded in cork), was placed on a sinusoidally moving platform with an amplitude of 1 cm and a period of 4 s. Ten-phase 4D computed tomography (CT) images of the phantom were acquired. A planning target volume (PTV) was created by adding a margin of 1 cm around the internal target volume ofmore » the tumor. (2) Three beams were designed, which included a static beam, a theoretical dynamic beam, and a planning-optimized dynamic beam (PODB). While the theoretical beam was made by manually programming a simplistic sliding leaf motion, the planning-optimized beam was obtained from treatment planning. From the three beams, three-dimensional (3D) doses on the phantom were calculated; 4D dose was calculated by means of the ten phase images (integrated over phases afterward); serving as “reference” images, phase-specific EPID dose images under the lung phantom were also calculated for each of the ten phases. (3) Cine EPID images were acquired while the beams were irradiated to the moving phantom. (4) Each cine image was phase-matched to a phase-specific CT image at which common irradiation occurred by intercomparing the cine image with the reference images. (5) Each cine image was used to reconstruct dose in the phase-matched CT image, and the reconstructed doses were summed over all phases. (6) The summation was compared with forwardly calculated 4D and 3D dose distributions. Accounting for realistic situations, intratreatment breathing irregularity was simulated by assuming an amplitude of 0.5 cm for the phantom during a portion of breathing trace in which the phase matching could not be performed. Intertreatment breathing irregularity between the time of treatment and the time of planning CT was considered by utilizing the same reduced amplitude when the phantom was irradiated. To examine the phase matching in a humanoid environment, the matching was also performed in a digital phantom (4D XCAT phantom). Results: For the static, the theoretical, and the planning-optimized dynamic beams, the 4D reconstructed doses showed agreement with the forwardly calculated 4D doses within the gamma pass rates of 92.7%, 100%, and 98.1%, respectively, at the isocenter plane given by 3%/3 mm criteria. Excellent agreement in dose volume histogram of PTV and lung-PTV was also found between the two 4D doses, while substantial differences were found between the 3D and the 4D doses. The significant breathing irregularities modeled in this study were found not to be noticeably affecting the reconstructed dose. The phase matching was performed equally well in a digital phantom. Conclusions: The method of retrospective phase determination of a moving object under irradiation provided successful 4D dose reconstruction. This method will provide accurate quality assurance and facilitate adaptive therapy when distinguishable objects such as well-defined tumors, diaphragm, and organs with markers (pancreas and liver) are covered by treatment beam apertures.« less
Yoon, Jihyung; Jung, Jae Won; Kim, Jong Oh; Yi, Byong Yong; Yeo, Inhwan
2016-07-01
A method is proposed to reconstruct a four-dimensional (4D) dose distribution using phase matching of measured cine images to precalculated images of electronic portal imaging device (EPID). (1) A phantom, designed to simulate a tumor in lung (a polystyrene block with a 3 cm diameter embedded in cork), was placed on a sinusoidally moving platform with an amplitude of 1 cm and a period of 4 s. Ten-phase 4D computed tomography (CT) images of the phantom were acquired. A planning target volume (PTV) was created by adding a margin of 1 cm around the internal target volume of the tumor. (2) Three beams were designed, which included a static beam, a theoretical dynamic beam, and a planning-optimized dynamic beam (PODB). While the theoretical beam was made by manually programming a simplistic sliding leaf motion, the planning-optimized beam was obtained from treatment planning. From the three beams, three-dimensional (3D) doses on the phantom were calculated; 4D dose was calculated by means of the ten phase images (integrated over phases afterward); serving as "reference" images, phase-specific EPID dose images under the lung phantom were also calculated for each of the ten phases. (3) Cine EPID images were acquired while the beams were irradiated to the moving phantom. (4) Each cine image was phase-matched to a phase-specific CT image at which common irradiation occurred by intercomparing the cine image with the reference images. (5) Each cine image was used to reconstruct dose in the phase-matched CT image, and the reconstructed doses were summed over all phases. (6) The summation was compared with forwardly calculated 4D and 3D dose distributions. Accounting for realistic situations, intratreatment breathing irregularity was simulated by assuming an amplitude of 0.5 cm for the phantom during a portion of breathing trace in which the phase matching could not be performed. Intertreatment breathing irregularity between the time of treatment and the time of planning CT was considered by utilizing the same reduced amplitude when the phantom was irradiated. To examine the phase matching in a humanoid environment, the matching was also performed in a digital phantom (4D XCAT phantom). For the static, the theoretical, and the planning-optimized dynamic beams, the 4D reconstructed doses showed agreement with the forwardly calculated 4D doses within the gamma pass rates of 92.7%, 100%, and 98.1%, respectively, at the isocenter plane given by 3%/3 mm criteria. Excellent agreement in dose volume histogram of PTV and lung-PTV was also found between the two 4D doses, while substantial differences were found between the 3D and the 4D doses. The significant breathing irregularities modeled in this study were found not to be noticeably affecting the reconstructed dose. The phase matching was performed equally well in a digital phantom. The method of retrospective phase determination of a moving object under irradiation provided successful 4D dose reconstruction. This method will provide accurate quality assurance and facilitate adaptive therapy when distinguishable objects such as well-defined tumors, diaphragm, and organs with markers (pancreas and liver) are covered by treatment beam apertures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lafata, K; Ren, L; Cai, J
2016-06-15
Purpose: To develop a methodology based on digitally-reconstructed-fluoroscopy (DRF) to quantitatively assess target localization accuracy of lung SBRT, and to evaluate using both a dynamic digital phantom and a patient dataset. Methods: For each treatment field, a 10-phase DRF is generated based on the planning 4DCT. Each frame is pre-processed with a morphological top-hat filter, and corresponding beam apertures are projected to each detector plane. A template-matching algorithm based on cross-correlation is used to detect the tumor location in each frame. Tumor motion relative beam aperture is extracted in the superior-inferior direction based on each frame’s impulse response to themore » template, and the mean tumor position (MTP) is calculated as the average tumor displacement. The DRF template coordinates are then transferred to the corresponding MV-cine dataset, which is retrospectively filtered as above. The treatment MTP is calculated within each field’s projection space, relative to the DRF-defined template. The field’s localization error is defined as the difference between the DRF-derived-MTP (planning) and the MV-cine-derived-MTP (delivery). A dynamic digital phantom was used to assess the algorithm’s ability to detect intra-fractional changes in patient alignment, by simulating different spatial variations in the MV-cine and calculating the corresponding change in MTP. Inter-and-intra-fractional variation, IGRT accuracy, and filtering effects were investigated on a patient dataset. Results: Phantom results demonstrated a high accuracy in detecting both translational and rotational variation. The lowest localization error of the patient dataset was achieved at each fraction’s first field (mean=0.38mm), with Fx3 demonstrating a particularly strong correlation between intra-fractional motion-caused localization error and treatment progress. Filtering significantly improved tracking visibility in both the DRF and MV-cine images. Conclusion: We have developed and evaluated a methodology to quantify lung SBRT target localization accuracy based on digitally-reconstructed-fluoroscopy. Our approach may be useful in potentially reducing treatment margins to optimize lung SBRT outcomes. R01-184173.« less
SU-C-17A-05: Quantification of Intra-Fraction Motion of Breast Tumors Using Cine-MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heijst, T van; Philippens, M; Bongard, D van den
2014-06-01
Purpose: Magnetic resonance imaging (MRI) enables direct characterization of intra-fraction motion ofbreast tumors, due to high softtissue contrast and geometric accuracy. The purpose is to analyzethis motion in early-stage breast-cancer patients using pre-operative supine cine-MRI. Methods: MRI was performed in 12 female early-stage breast-cancer patients on a 1.5-T Ingenia (Philips)wide-bore scanner in supine radiotherapy (RT) position, prior to breast-conserving surgery. Twotwodimensional (2D) T2-weighted balanced fast-field echo (cine-MRI) sequences were added tothe RT protocol, oriented through the tumor. They were alternately acquired in the transverse andsagittal planes, every 0.3 s during 1 min. A radiation oncologist delineated gross target volumes(GTVs) onmore » 3D contrast-enhanced MRI. Clinical target volumes (CTV = GTV + 15 mm isotropic)were generated and transferred onto the fifth time-slice of the time-series, to which subsequents lices were registered using a non-rigid Bspline algorithm; delineations were transformed accordingly. To evaluate intra-fraction CTV motion, deformation fields between the transformed delineations were derived to acquire the distance ensuring 95% surface coverage during scanning(P95%), for all in-plane directions: anteriorposterior (AP), left-right (LR), and caudal-cranial(CC). Information on LR was derived from transverse scans, CC from sagittal scans, AP fromboth sets. Results: Time-series with registration errors - induced by motion artifacts - were excluded by visual inspection. For our analysis, 11 transverse, and 8 sagittal time-series were taken into account. Themedian P95% calculated in AP (19 series), CC (8), and LR (11) was 1.8 mm (range: 0.9–4.8), 1.7mm (0.8–3.6), and 1.0 mm (0.6–3.5), respectively. Conclusion: Intra-fraction motion analysis of breast tumors was achieved using cine-MRI. These first results show that in supine RT position, motion amplitudes are limited. This information can be used for adaptive RT planning, and to develop preoperative partial-breast RT strategies, such asablative RT for early-stage breast-cancer patients.« less
Fischer-Valuck, Benjamin W; Henke, Lauren; Green, Olga; Kashani, Rojano; Acharya, Sahaja; Bradley, Jeffrey D; Robinson, Clifford G; Thomas, Maria; Zoberi, Imran; Thorstad, Wade; Gay, Hiram; Huang, Jiayi; Roach, Michael; Rodriguez, Vivian; Santanam, Lakshmi; Li, Harold; Li, Hua; Contreras, Jessika; Mazur, Thomas; Hallahan, Dennis; Olsen, Jeffrey R; Parikh, Parag; Mutic, Sasa; Michalski, Jeff
2017-01-01
Magnetic resonance image guided radiation therapy (MR-IGRT) has been used at our institution since 2014. We report on more than 2 years of clinical experience in treating patients with the world's first MR-IGRT system. A clinical service was opened for MR-IGRT in January 2014 with an MR-IGRT system consisting of a split 0.35T magnetic resonance scanner that straddles a ring gantry with 3 multileaf collimator-equipped 60 Co heads. The service was expanded to include online adaptive radiation therapy (ART) MR-IGRT and cine gating after 6 and 9 months, respectively. Patients selected for MR-IGRT were enrolled in a prospective registry between January 2014 and June 2016. Patients were treated with a variety of radiation therapy techniques including intensity modulated radiation therapy and stereotactic body radiation therapy (SBRT). When applicable, online ART was performed and gating on sagittal 2-dimensional cine MR was used. The charts of patients treated with MR-IGRT were reviewed to report on the clinical and treatment characteristics of the initial patients who were treated with this novel technique. A total of 316 patients have been treated with the MR-IGRT system, which has been integrated into a high-volume clinic. The cases were most commonly selected for improved soft tissue visualization, ART, and cine gating. Seventy-six patients were treated with 3-dimensional conformal radiation therapy, 146 patients with intensity modulated radiation therapy, and 94 patients with SBRT. The most commonly treated disease sites were the abdomen (28%), breast (26%), pelvis (22%), thorax (19%), and head and neck (5%). Sixty-seven patients were treated with online ART over a total of 244 adapted fractions. Cine treatment gating was used for a total of 81 patients. MR-IGRT has been successfully implemented in a high-volume radiation clinic and provides unique advantages in the treatment of a variety of malignancies. Additional clinical trials are in development to formally evaluate MR-IGRT in the treatment of multiple disease sites with techniques such as SBRT and ART.
Sadat, Umar; Usman, Ammara; Howarth, Simon P S; Tang, Tjun Y; Alam, Fahreyar; Graves, Martin J; Gillard, Jonathan H
2014-04-01
Atherosclerosis is a systemic inflammatory disease that may affect multiple arterial beds simultaneously. Vascular distensibility is increasingly used in the clinical assessment of patients with atherosclerotic disease. In this study, we assess distensibility of symptomatic atherosclerotic carotid artery and of contralateral asymptomatic side. We also investigate the distensibility of bilaterally asymptomatic atherosclerotic carotid arteries using cine phase-contrast carotid magnetic resonance (MR) imaging. Nineteen patients with bilateral carotid artery disease underwent cine phase-contrast carotid imaging on a 1.5 T MR system. Ten patients had ipsilateral symptomatic carotid artery disease and contralateral asymptomatic stenosis. Nine additional patients with bilateral asymptomatic carotid artery disease constituted historical control group. Cine phase-contrast MR imaging acquired at the common carotid artery, maximum luminal stenosis, and internal carotid artery was used to determine carotid distensibility bilaterally for carotid arteries in both patient groups. Symptomatic carotid arteries were found to be significantly less distensible (mean distensibility coefficient [DC] 35.4 ± 6.12 × 10(-3)/kPa) than the contralateral asymptomatic vessels (mean DC 54.4 ± 7.88 × 10(-3)/kPa, P = .03) at the level of the common carotid artery. A similar trend of high distensibility for asymptomatic side in the area of maximum stenosis and the internal carotid artery was seen, but it was not found to be statistically significant. Plaque burden was comparable between the 2 groups at all locations. DC was comparable for patients with bilateral asymptomatic carotid artery stenoses. Distensibility of bilaterally asymptomatic carotid arteries was greater than that of asymptomatic carotid artery contralateral to the symptomatic side. Symptomatic carotid artery is stiffer than the contralateral asymptomatic side, despite comparable plaque burden. Patients with bilateral asymptomatic carotid artery disease have comparable stiffness. Larger studies are warranted to further investigate the findings of this MR study. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shiinoki, T; Hanazawa, H; Shibuya, K
Purpose: The respirato ry gating system combined the TrueBeam and a new real-time tumor-tracking radiotherapy system (RTRT) was installed. The RTRT system consists of two x-ray tubes and color image intensifiers. Using fluoroscopic images, the fiducial marker which was implanted near the tumor was tracked and was used as the internal surrogate for respiratory gating. The purposes of this study was to develop the verification technique of the respiratory gating with the new RTRT using cine electronic portal image device images (EPIDs) of TrueBeam and log files of the RTRT. Methods: A patient who underwent respiratory gated SBRT of themore » lung using the RTRT were enrolled in this study. For a patient, the log files of three-dimensional coordinate of fiducial marker used as an internal surrogate were acquired using the RTRT. Simultaneously, the cine EPIDs were acquired during respiratory gated radiotherapy. The data acquisition was performed for one field at five sessions during the course of SBRT. The residual motion errors were calculated using the log files (E{sub log}). The fiducial marker used as an internal surrogate into the cine EPIDs was automatically extracted by in-house software based on the template-matching algorithm. The differences between the the marker positions of cine EPIDs and digitally reconstructed radiograph were calculated (E{sub EPID}). Results: Marker detection on EPID using in-house software was influenced by low image contrast. For one field during the course of SBRT, the respiratory gating using the RTRT showed the mean ± S.D. of 95{sup th} percentile E{sub EPID} were 1.3 ± 0.3 mm,1.1 ± 0.5 mm,and those of E{sub log} were 1.5 ± 0.2 mm, 1.1 ± 0.2 mm in LR and SI directions, respectively. Conclusion: We have developed the verification method of respiratory gating combined TrueBeam and new real-time tumor-tracking radiotherapy system using EPIDs and log files.« less
Hamlet, Sean M; Haggerty, Christopher M; Suever, Jonathan D; Wehner, Gregory J; Andres, Kristin N; Powell, David K; Zhong, Xiaodong; Fornwalt, Brandon K
2017-03-01
To determine the optimal respiratory navigator gating configuration for the quantification of left ventricular strain using spiral cine displacement encoding with stimulated echoes (DENSE) MRI. Two-dimensional spiral cine DENSE was performed on a 3 Tesla MRI using two single-navigator configurations (retrospective, prospective) and a combined "dual-navigator" configuration in 10 healthy adults and 20 healthy children. The adults also underwent breathhold DENSE as a reference standard for comparisons. Peak left ventricular strains, signal-to-noise ratio (SNR), and navigator efficiency were compared. Subjects also underwent dual-navigator gating with and without visual feedback to determine the effect on navigator efficiency. There were no differences in circumferential, radial, and longitudinal strains between navigator-gated and breathhold DENSE (P = 0.09-0.95) (as confidence intervals, retrospective: [-1.0%-1.1%], [-7.4%-2.0%], [-1.0%-1.2%]; prospective: [-0.6%-2.7%], [-2.8%-8.3%], [-0.3%-2.9%]; dual: [-1.6%-0.5%], [-8.3%-3.2%], [-0.8%-1.9%], respectively). The dual configuration maintained SNR compared with breathhold acquisitions (16 versus 18, P = 0.06). SNR for the prospective configuration was lower than for the dual navigator in adults (P = 0.004) and children (P < 0.001). Navigator efficiency was higher (P < 0.001) for both retrospective (54%) and prospective (56%) configurations compared with the dual configuration (35%). Visual feedback improved the dual configuration navigator efficiency to 55% (P < 0.001). When quantifying left ventricular strains using spiral cine DENSE MRI, a dual navigator configuration results in the highest SNR in adults and children. In adults, a retrospective configuration has good navigator efficiency without a substantial drop in SNR. Prospective gating should be avoided because it has the lowest SNR. Visual feedback represents an effective option to maintain navigator efficiency while using a dual navigator configuration. 2 J. Magn. Reson. Imaging 2017;45:786-794. © 2016 International Society for Magnetic Resonance in Medicine.
Hamlet, Sean M.; Haggerty, Christopher M.; Suever, Jonathan D.; Wehner, Gregory J.; Andres, Kristin N.; Powell, David K.; Fornwalt, Brandon K.
2016-01-01
Purpose To determine the optimal respiratory navigator gating configuration for the quantification of left ventricular strain using spiral cine displacement encoding with stimulated echoes (DENSE) MRI. Materials and Methods 2D spiral cine DENSE was performed on a 3T MRI using two single-navigator configurations (retrospective, prospective), and a combined “dual-navigator” configuration in 10 healthy adults and 20 healthy children. The adults also underwent breath-hold DENSE as a reference standard for comparisons. Peak left ventricular strains, signal-to-noise ratio (SNR) and navigator efficiency were compared. Subjects also underwent dual-navigator gating with and without visual feedback to determine the effect on navigator efficiency. Results There were no differences in circumferential, radial and longitudinal strains between navigator-gated and breath-hold DENSE (p=0.09–0.95) (as confidence intervals, retrospective: [−1.0%,1.1%],[−7.4%,2.0%],[−1.0%,1.2%]; prospective: [−0.6%,2.7%],[−2.8%,8.3%],[−0.3%,2.9%]; dual: [−1.6%,0.5%],[−8.3%,3.2%],[−0.8%,1.9%], respectively). The dual configuration maintained SNR compared to breath-hold acquisitions (16 vs. 18, p=0.06). SNR for the prospective configuration was lower than for the dual navigator in adults (p=0.004) and children (p<0.001). Navigator efficiency was higher (p<0.001) for both retrospective (54%) and prospective (56%) configurations compared to the dual configuration (35%). Visual feedback improved the dual configuration navigator efficiency to 55% (p<0.001). Conclusion When quantifying left ventricular strains using spiral cine DENSE MRI, a dual navigator configuration results in the highest SNR in adults and children. In adults, a retrospective configuration has good navigator efficiency without a substantial drop in SNR. Prospective gating should be avoided since it has the lowest SNR. Visual feedback represents an effective option to maintain navigator efficiency while using a dual navigator configuration. PMID:27458823
Presentación del estudio "Links" de hombres que tienes sexo con hombres en Buenos Aires, Argentina.
Carballo-Diéguez, Alex; Avila, María M; Balán, Iván C; Marone, Rubén; Pando, María A; Barreda, Victoria
2011-03-01
Estudios previos en Buenos Aires reportaron altas prevalencias de HIV entre HSH, con valores que oscilan entre 9 y 14% durante casi 10 años de continuo testeo. El objetivo principal de este estudio fue la evaluación de factores relacionados al comportamiento de alto riesgo para transmisión del HIV entre HSH entre los que se incluyen el conocimiento y factores emocionales, socioculturales y ambientales. Por otro lado se realizó la estimación de prevalencia e incidencia de HIV utilizando RDS (Respondent Driven Sampling), así como la presencia de otras infecciones de transmisión sexual. Por último se evaluaron los hábitos de testeo para HIV indagando que factores facilitan o impiden su realización. El estudio constó de dos fases, en primer lugar una fase cualitativa y posteriormente una fase cuantitativa con una duración total de 4 años y medio. Durante la fase cualitativa se realizaron 44 entrevistas individuales en profundidad, 8 grupos focales y 10 observaciones etnográficas (hoteles, baños públicos ("teteras"), cines pornográficos, fiestas privadas, dark rooms y discotecas). Durante la fase cuantitativa del estudio se realizó el reclutamiento de 500 participantes que provinieron de la Ciudad Autónoma de Buenos Aires, así como del Gran Buenos Aires. El reclutamiento se comenzó con 16 participantes llamados semillas. Se realizó el diagnóstico de infección por HIV, hepatitis B y C (HBV y HCV), Treponema pallidum, Virus Papiloma Humano (HPV) y Chlamidias. La colaboración establecida entre los grupos de trabajo enfocados en áreas diversas posibilitó el abordaje conjunto de nuevas estrategias de investigación antes no exploradas en nuestro país. Los resultados más relevantes de esta investigación serán progresivamente publicados en sucesivos números de Actualizaciones en SIDA.
Helical 4D CT and Comparison with Cine 4D CT
NASA Astrophysics Data System (ADS)
Pan, Tinsu
4D CT was one of the most important developments in radiation oncology in the last decade. Its early development in single slice CT and commercialization in multi-slice CT has radically changed our practice in radiation treatment of lung cancer, and has enabled the stereotactic radiosurgery of early stage lung cancer. In this chapter, we will document the history of 4D CT development, detail the data sufficiency condition governing the 4D CT data collection; present the design of the commercial helical 4D CTs from Philips and Siemens; compare the differences between the helical 4D CT and the GE cine 4D CT in data acquisition, slice thickness, acquisition time and work flow; review the respiratory monitoring devices; and understand the causes of image artifacts in 4D CT.
Real-time cardiovascular magnetic resonance at 1.5 T using balanced SSFP and 40 ms resolution
2013-01-01
Background While cardiovascular magnetic resonance (CMR) commonly employs ECG-synchronized cine acquisitions with balanced steady-state free precession (SSFP) contrast at 1.5 T, recent developments at 3 T demonstrate significant potential for T1-weighted real-time imaging at high spatiotemporal resolution using undersampled radial FLASH. The purpose of this work was to combine both ideas and to evaluate a corresponding real-time CMR method at 1.5 T with SSFP contrast. Methods Radial gradient-echo sequences with fully balanced gradients and at least 15-fold undersampling were implemented on two CMR systems with different gradient performance. Image reconstruction by regularized nonlinear inversion (NLINV) was performed offline and resulted in real-time SSFP CMR images at a nominal resolution of 1.8 mm and with acquisition times of 40 ms. Results Studies of healthy subjects demonstrated technical feasibility in terms of robustness and general image quality. Clinical applicability with access to quantitative evaluations (e.g., ejection fraction) was confirmed by preliminary applications to 27 patients with typical indications for CMR including arrhythmias and abnormal wall motion. Real-time image quality was slightly lower than for cine SSFP recordings, but considered diagnostic in all cases. Conclusions Extending conventional cine approaches, real-time radial SSFP CMR with NLINV reconstruction provides access to individual cardiac cycles and allows for studies of patients with irregular heartbeat. PMID:24028285
NASA Astrophysics Data System (ADS)
Ben-Zikri, Yehuda Kfir; Linte, Cristian A.
2016-03-01
Region of interest detection is a precursor to many medical image processing and analysis applications, including segmentation, registration and other image manipulation techniques. The optimal region of interest is often selected manually, based on empirical knowledge and features of the image dataset. However, if inconsistently identified, the selected region of interest may greatly affect the subsequent image analysis or interpretation steps, in turn leading to incomplete assessment during computer-aided diagnosis or incomplete visualization or identification of the surgical targets, if employed in the context of pre-procedural planning or image-guided interventions. Therefore, the need for robust, accurate and computationally efficient region of interest localization techniques is prevalent in many modern computer-assisted diagnosis and therapy applications. Here we propose a fully automated, robust, a priori learning-based approach that provides reliable estimates of the left and right ventricle features from cine cardiac MR images. The proposed approach leverages the temporal frame-to-frame motion extracted across a range of short axis left ventricle slice images with small training set generated from les than 10% of the population. This approach is based on histogram of oriented gradients features weighted by local intensities to first identify an initial region of interest depicting the left and right ventricles that exhibits the greatest extent of cardiac motion. This region is correlated with the homologous region that belongs to the training dataset that best matches the test image using feature vector correlation techniques. Lastly, the optimal left ventricle region of interest of the test image is identified based on the correlation of known ground truth segmentations associated with the training dataset deemed closest to the test image. The proposed approach was tested on a population of 100 patient datasets and was validated against the ground truth region of interest of the test images manually annotated by experts. This tool successfully identified a mask around the LV and RV and furthermore the minimal region of interest around the LV that fully enclosed the left ventricle from all testing datasets, yielding a 98% overlap with their corresponding ground truth. The achieved mean absolute distance error between the two contours that normalized by the radius of the ground truth is 0.20 +/- 0.09.
UWGSP4: an imaging and graphics superworkstation and its medical applications
NASA Astrophysics Data System (ADS)
Jong, Jing-Ming; Park, Hyun Wook; Eo, Kilsu; Kim, Min-Hwan; Zhang, Peng; Kim, Yongmin
1992-05-01
UWGSP4 is configured with a parallel architecture for image processing and a pipelined architecture for computer graphics. The system's peak performance is 1,280 MFLOPS for image processing and over 200,000 Gouraud shaded 3-D polygons per second for graphics. The simulated sustained performance is about 50% of the peak performance in general image processing. Most of the 2-D image processing functions are efficiently vectorized and parallelized in UWGSP4. A performance of 770 MFLOPS in convolution and 440 MFLOPS in FFT is achieved. The real-time cine display, up to 32 frames of 1280 X 1024 pixels per second, is supported. In 3-D imaging, the update rate for the surface rendering is 10 frames of 20,000 polygons per second; the update rate for the volume rendering is 6 frames of 128 X 128 X 128 voxels per second. The system provides 1280 X 1024 X 32-bit double frame buffers and one 1280 X 1024 X 8-bit overlay buffer for supporting realistic animation, 24-bit true color, and text annotation. A 1280 X 1024- pixel, 66-Hz noninterlaced display screen with 1:1 aspect ratio can be windowed into the frame buffer for the display of any portion of the processed image or graphics.
Testing Taylor’s hypothesis in Amazonian rainfall fields during the WETAMC/LBA experiment
NASA Astrophysics Data System (ADS)
Poveda, Germán; Zuluaga, Manuel D.
2005-11-01
Taylor's hypothesis (TH) for rainfall fields states that the spatial correlation of rainfall intensity at two points at the same instant of time can be equated with the temporal correlation at two instants of time at some fixed location. The validity of TH is tested in a set of 12 storms developed in Rondonia, southwestern Amazonia, Brazil, during the January-February 1999 Wet Season Atmospheric Meso-scale Campaign. The time Eulerian and Lagrangian Autocorrelation Functions (ACF) are estimated, as well as the time-averaged space ACF, using radar rainfall rates of storms spanning between 3.2 and 23 h, measured at 7-10-min time resolution, over a circle of 100 km radius, at 2 km spatial resolution. TH does not hold in 9 out of the 12 studied storms, due to their erratic trajectories and very low values of zonal wind velocity at 700 hPa, independently from underlying atmospheric stability conditions. TH was shown to hold for 3 storms, up to a cutoff time scale of 10-15 min, which is closely related to observed features of the life cycle of convective cells in the region. Such cutoff time scale in Amazonian storms is much shorter than the 40 min identified in mid-latitude convective storms, due to much higher values of CAPE and smaller values of storm speed in Amazonian storms as compared to mid-latitude ones, which in turn contribute to a faster destruction of the rainfall field isotropy. Storms satisfying TH undergo smooth linear trajectories over space, and exhibit the highest negative values of maximum, mean and minimum zonal wind velocity at 700 hPa, within narrow ranges of atmospheric stability conditions. Non-dimensional parameters involving CAPE (maximum, mean and minimum) and CINE (mean) are identified during the storms life cycle, for which TH holds: CAPE mean/CINE mean = [30-35], CAPE max/CINE mean = [32-40], and CAPE min/CINE mean = [22-28]. These findings are independent upon the timing of storms within the diurnal cycle. Also, the estimated Eulerian time ACF's decay faster than the time-averaged space and the Lagrangian time ACF's, irrespectively of TH validity. The Eulerian ACF's exhibit shorter e-folding times, reflecting smaller correlations over short time scales, but also shorter scale of fluctuation, reflecting less persistence in time than over space. No significant associations (linear, exponential or power law) were found between estimated e-folding times and scale of fluctuation, with all estimates of CAPE and CINE. Secondary correlation maxima appear between 50 and 70 min in the Lagrangian time ACF's for storms satisfying TH. No differences were found in the behavior of each of the three ACF's for storms developed during either the Easterly or Westerly zonal wind regimes which characterize the development of meso-scale convective systems over the region. These results have important implications for modelling and downscaling rainfall fields over tropical land areas.
Investigation of sagittal image acquisition for 4D-MRI with body area as respiratory surrogate.
Liu, Yilin; Yin, Fang-Fang; Chang, Zheng; Czito, Brian G; Palta, Manisha; Bashir, Mustafa R; Qin, Yujiao; Cai, Jing
2014-10-01
The authors have recently developed a novel 4D-MRI technique for imaging organ respiratory motion employing cine acquisition in the axial plane and using body area (BA) as a respiratory surrogate. A potential disadvantage associated with axial image acquisition is the space-dependent phase shift in the superior-inferior (SI) direction, i.e., different axial slice positions reach the respiratory peak at different respiratory phases. Since respiratory motion occurs mostly in the SI and anterior-posterior (AP) directions, sagittal image acquisition, which embeds motion information in these two directions, is expected to be more robust and less affected by phase-shift than axial image acquisition. This study aims to develop and evaluate a 4D-MRI technique using sagittal image acquisition. The authors evaluated axial BA and sagittal BA using both 4D-CT images (11 cancer patients) and cine MR images (6 healthy volunteers and 1 cancer patient) by comparing their corresponding space-dependent phase-shift in the SI direction (δSPS (SI)) and in the lateral direction (δSPS (LAT)), respectively. To evaluate sagittal BA 4D-MRI method, a motion phantom study and a digital phantom study were performed. Additionally, six patients who had cancer(s) in the liver were prospectively enrolled in this study. For each patient, multislice sagittal MR images were acquired for 4D-MRI reconstruction. 4D retrospective sorting was performed based on respiratory phases. Single-slice cine MRI was also acquired in the axial, coronal, and sagittal planes across the tumor center from which tumor motion trajectories in the SI, AP, and medial-lateral (ML) directions were extracted and used as references from comparison. All MR images were acquired in a 1.5 T scanner using a steady-state precession sequence (frame rate ∼ 3 frames/s). 4D-CT scans showed that δSPS (SI) was significantly greater than δSPS (LAT) (p-value: 0.012); the median phase-shift was 16.9% and 7.7%, respectively. Body surface motion measurement from axial and sagittal MR cines also showed δSPS (SI) was significantly greater than δSPS (LAT). The median δSPS (SI) and δSPS (LAT) was 11.0% and 9.2% (p-value = 0.008), respectively. Tumor motion trajectories from 4D-MRI matched with those from single-slice cine MRI: the mean (±SD) absolute differences in tumor motion amplitude between the two were 1.5 ± 1.6 mm, 2.1 ± 1.9 mm, and 1.1 ± 1.0 mm in the SI, ML, and AP directions from this patient study. Space-dependent phase shift is less problematic for sagittal acquisition than for axial acquisition. 4D-MRI using sagittal acquisition was successfully carried out in patients with hepatic tumors.
Wright, Benjamin; Summers, Angela; Fenner, John; Gillott, Richard; Hutchinson, Charles E; Spencer, Paul A; Wilkie, Martin; Hurst, Helen; Herrick, Sarah; Brenchley, Paul; Augustine, Titus; Bardhan, Karna D
2011-01-01
Encapsulating peritoneal sclerosis (EPS) is an uncommon complication of peritoneal dialysis (PD), with high mortality and morbidity. The peritoneum thickens, dysfunctions, and forms a cocoon that progressively "strangulates" the small intestine, causing malnutrition, ischemia, and infarction. There is as yet no reliable noninvasive means of diagnosis, but recent developments in image analysis of cine magnetic resonance imaging for the recognition of adhesions offers a way forward. We used this protocol before surgery in 3 patients with suspected EPS. Image analysis revealed patterns of abdominal movement that were markedly different from the patterns in healthy volunteers. The volunteers showed marked movement throughout the abdomen; in contrast, movement in EPS patients was restricted to just below the diaphragm. This clear difference provides early "proof of principle" of the approach that we have developed.
Lundin, B; Cooper, T G; Meyer, R A; Potchen, E J
1993-01-01
Two independent measurements of total renal blood flow (RBF) were made in healthy human subjects (n = 14, mean age 30 yr) by CINE phase-contrast magnetic resonance angiography. RBF, measured by summing the flows measured in the right and left renal arteries, was 1152 +/- 44 ml/min (mean +/- SE). RBF, measured from the difference between supra- and infrarenal abdominal aorta flow, was 1109 +/- 68 ml/min. Regression analysis of the comparison of these two different RBF calculations yielded a correlation coefficient of 0.72 at a p < .05 level of significance. Based on other studies of RBF in normal subjects by para-aminohippuric acid (PAH) clearance, the expected RBF in this subject group was 1211 +/- 62 ml/min. The results indicate that noninvasive measurement of RBF is possible using phase-contrast magnetic resonance methods.
Cine: Line excitation by infrared fluorescence in cometary atmospheres
NASA Astrophysics Data System (ADS)
de Val-Borro, Miguel; Cordiner, Martin A.; Milam, Stefanie N.; Charnley, Steven B.
2017-03-01
CINE is a Python module for calculating infrared pumping efficiencies that can be applied to the most common molecules found in cometary comae such as water, hydrogen cyanide or methanol. Excitation by solar radiation of vibrational bands followed by radiative decay to the ground vibrational state is one of the main mechanisms for molecular excitation in comets. This code calculates the effective pumping rates for rotational levels in the ground vibrational state scaled by the heliocentric distance of the comet. Line transitions are queried from the latest version of the HITRAN spectroscopic repository using the astroquery affiliated package of astropy. Molecular data are obtained from the LAMDA database. These coefficients are useful for modeling rotational emission lines observed in cometary spectra at sub-millimeter wavelengths. Combined with computational methods to solve the radiative transfer equations based, e.g., on the Monte Carlo algorithm, this model can retrieve production rates and rotational temperatures from the observed emission spectrum.
Validation of motion correction techniques for liver CT perfusion studies
Chandler, A; Wei, W; Anderson, E F; Herron, D H; Ye, Z; Ng, C S
2012-01-01
Objectives Motion in images potentially compromises the evaluation of temporally acquired CT perfusion (CTp) data; image registration should mitigate this, but first requires validation. Our objective was to compare the relative performance of manual, rigid and non-rigid registration techniques to correct anatomical misalignment in acquired liver CTp data sets. Methods 17 data sets in patients with liver tumours who had undergone a CTp protocol were evaluated. Each data set consisted of a cine acquisition during a breath-hold (Phase 1), followed by six further sets of cine scans (each containing 11 images) acquired during free breathing (Phase 2). Phase 2 images were registered to a reference image from Phase 1 cine using two semi-automated intensity-based registration techniques (rigid and non-rigid) and a manual technique (the only option available in the relevant vendor CTp software). The performance of each technique to align liver anatomy was assessed by four observers, independently and blindly, on two separate occasions, using a semi-quantitative visual validation study (employing a six-point score). The registration techniques were statistically compared using an ordinal probit regression model. Results 306 registrations (2448 observer scores) were evaluated. The three registration techniques were significantly different from each other (p=0.03). On pairwise comparison, the semi-automated techniques were significantly superior to the manual technique, with non-rigid significantly superior to rigid (p<0.0001), which in turn was significantly superior to manual registration (p=0.04). Conclusion Semi-automated registration techniques achieved superior alignment of liver anatomy compared with the manual technique. We hope this will translate into more reliable CTp analyses. PMID:22374283
NASA Astrophysics Data System (ADS)
Gao, Bin; Liu, Wanyu; Wang, Liang; Liu, Zhengjun; Croisille, Pierre; Delachartre, Philippe; Clarysse, Patrick
2016-12-01
Cine-MRI is widely used for the analysis of cardiac function in clinical routine, because of its high soft tissue contrast and relatively short acquisition time in comparison with other cardiac MRI techniques. The gray level distribution in cardiac cine-MRI is relatively homogenous within the myocardium, and can therefore make motion quantification difficult. To ensure that the motion estimation problem is well posed, more image features have to be considered. This work is inspired by a method previously developed for color image processing. The monogenic signal provides a framework to estimate the local phase, orientation, and amplitude, of an image, three features which locally characterize the 2D intensity profile. The independent monogenic features are combined into a 3D matrix for motion estimation. To improve motion estimation accuracy, we chose the zero-mean normalized cross-correlation as a matching measure, and implemented a bilateral filter for denoising and edge-preservation. The monogenic features distance is used in lieu of the color space distance in the bilateral filter. Results obtained from four realistic simulated sequences outperformed two other state of the art methods even in the presence of noise. The motion estimation errors (end point error) using our proposed method were reduced by about 20% in comparison with those obtained by the other tested methods. The new methodology was evaluated on four clinical sequences from patients presenting with cardiac motion dysfunctions and one healthy volunteer. The derived strain fields were analyzed favorably in their ability to identify myocardial regions with impaired motion.
Radiation dose and image quality for paediatric interventional cardiology
NASA Astrophysics Data System (ADS)
Vano, E.; Ubeda, C.; Leyton, F.; Miranda, P.
2008-08-01
Radiation dose and image quality for paediatric protocols in a biplane x-ray system used for interventional cardiology have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-20 cm of PMMA). Images from fluoroscopy (low, medium and high) and cine modes have been archived in digital imaging and communications in medicine (DICOM) format. Signal-to-noise ratio (SNR), figure of merit (FOM), contrast (CO), contrast-to-noise ratio (CNR) and high contrast spatial resolution (HCSR) have been computed from the images. Data on dose transferred to the DICOM header have been used to test the values of the dosimetric display at the interventional reference point. ESAK for fluoroscopy modes ranges from 0.15 to 36.60 µGy/frame when moving from 4 to 20 cm PMMA. For cine, these values range from 2.80 to 161.10 µGy/frame. SNR, FOM, CO, CNR and HCSR are improved for high fluoroscopy and cine modes and maintained roughly constant for the different thicknesses. Cumulative dose at the interventional reference point resulted 25-45% higher than the skin dose for the vertical C-arm (depending of the phantom thickness). ESAK and numerical image quality parameters allow the verification of the proper setting of the x-ray system. Knowing the increases in dose per frame when increasing phantom thicknesses together with the image quality parameters will help cardiologists in the good management of patient dose and allow them to select the best imaging acquisition mode during clinical procedures.
NASA Astrophysics Data System (ADS)
Jiang, Luan; Ling, Shan; Li, Qiang
2016-03-01
Cardiovascular diseases are becoming a leading cause of death all over the world. The cardiac function could be evaluated by global and regional parameters of left ventricle (LV) of the heart. The purpose of this study is to develop and evaluate a fully automated scheme for segmentation of LV in short axis cardiac cine MR images. Our fully automated method consists of three major steps, i.e., LV localization, LV segmentation at end-diastolic phase, and LV segmentation propagation to the other phases. First, the maximum intensity projection image along the time phases of the midventricular slice, located at the center of the image, was calculated to locate the region of interest of LV. Based on the mean intensity of the roughly segmented blood pool in the midventricular slice at each phase, end-diastolic (ED) and end-systolic (ES) phases were determined. Second, the endocardial and epicardial boundaries of LV of each slice at ED phase were synchronously delineated by use of a dual dynamic programming technique. The external costs of the endocardial and epicardial boundaries were defined with the gradient values obtained from the original and enhanced images, respectively. Finally, with the advantages of the continuity of the boundaries of LV across adjacent phases, we propagated the LV segmentation from the ED phase to the other phases by use of dual dynamic programming technique. The preliminary results on 9 clinical cardiac cine MR cases show that the proposed method can obtain accurate segmentation of LV based on subjective evaluation.
Steeden, Jennifer A; Muthurangu, Vivek
2015-04-01
1) To validate an R-R interval averaged golden angle spiral phase contrast magnetic resonance (RAGS PCMR) sequence against conventional cine PCMR for assessment of renal blood flow (RBF) in normal volunteers; and 2) To investigate the effects of motion and heart rate on the accuracy of flow measurements using an in silico simulation. In 20 healthy volunteers RAGS (∼6 sec breath-hold) and respiratory-navigated cine (∼5 min) PCMR were performed in both renal arteries to assess RBF. A simulation of RAGS PCMR was used to assess the effect of heart rate (30-105 bpm), vessel expandability (0-150%) and translational motion (x1.0-4.0) on the accuracy of RBF measurements. There was good agreement between RAGS and cine PCMR in the volunteer study (bias: 0.01 L/min, limits of agreement: -0.04 to +0.06 L/min, P = 0.0001). The simulation demonstrated a positive linear relationship between heart rate and error (r = 0.9894, P < 0.0001), a negative linear relationship between vessel expansion and error (r = -0.9484, P < 0.0001), and a nonlinear, heart rate-dependent relationship between vessel translation and error. We have demonstrated that RAGS PCMR accurately measures RBF in vivo. However, the simulation reveals limitations in this technique at extreme heart rates (<40 bpm, >100 bpm), or when there is significant motion (vessel expandability: >80%, vessel translation: >x2.2). © 2014 Wiley Periodicals, Inc.
Borotikar, Bhushan S.; Sheehan, Frances T.
2017-01-01
Objectives To establish an in vivo, normative patellofemoral cartilage contact mechanics database acquired during voluntary muscle control using a novel dynamic magnetic resonance (MR) imaging-based computational methodology and validate the contact mechanics sensitivity to the known sub-millimeter methodological inaccuracies. Design Dynamic cine phase-contrast and multi-plane cine images were acquired while female subjects (n=20, sample of convenience) performed an open kinetic chain (knee flexion-extension) exercise inside a 3-Tesla MR scanner. Static cartilage models were created from high resolution three-dimensional static MR data and accurately placed in their dynamic pose at each time frame based on the cine-PC data. Cartilage contact parameters were calculated based on the surface overlap. Statistical analysis was performed using paired t-test and a one-sample repeated measures ANOVA. The sensitivity of the contact parameters to the known errors in the patellofemoral kinematics was determined. Results Peak mean patellofemoral contact area was 228.7±173.6mm2 at 40° knee angle. During extension, contact centroid and peak strain locations tracked medially on the femoral and patellar cartilage and were not significantly different from each other. At 30°, 35°, and 40° of knee extension, contact area was significantly different. Contact area and centroid locations were insensitive to rotational and translational perturbations. Conclusion This study is a first step towards unfolding the biomechanical pathways to anterior patellofemoral pain and OA using dynamic, in vivo, and accurate methodologies. The database provides crucial data for future studies and for validation of, or as an input to, computational models. PMID:24012620
Egeler-Peerdeman, S M; Barkhof, F; Walchenbach, R; Valk, J
1998-01-01
Phase-contrast cine MR flow imaging through the aqueduct was used to establish the diagnosis of normal pressure hydrocephalus (NPH), and to predict outcome after shunting. From 1990-1994 16 patients, who were participants in the Dutch Normal Pressure Hydrocephalus Study [3], were studied. The patients included in this study met clinical and CT-scan criteria as described in this study, underwent cine phase-contrast MR imaging prior to placement of a CSF shunt, and had a follow-up 12 months after the operation. Claustrophobic patients, patients with a pacemaker or extremely agitated patients were excluded. Normal Flux was calculated in each patients, as the average difference in caudal and rostral flux (Fdiff) +2 times standard deviation (0.97 cc/sec) [2]. The clinical outcome was measured with a modified scale of activities of daily living (ADL) as described by Rankin. Of the 16 patients, 8 could not be evaluated due to restlessness during MR measurements, disabling cerebral vascular accidents or death before the end of the follow-up period. Of the remaining 8 patients, 5 had a normal flux, of which only one improved. Two patients had a Fdiff twice the normal range, which improved in both patients. One patient had no measurable flux, consistent with an aqueduct stenosis; he too improved. Overall, there was a concordance of MR findings with final outcome after shunting in 7 out of 8 patients. This pilot study, therefore, support the need to further evaluate flow with MR imaging techniques to select patients with shunt responsive NPH.
Effects of Spaceflight on Astronaut Brain Structure as Indicated on MRI.
Roberts, Donna R; Albrecht, Moritz H; Collins, Heather R; Asemani, Davud; Chatterjee, A Rano; Spampinato, M Vittoria; Zhu, Xun; Chimowitz, Marc I; Antonucci, Michael U
2017-11-02
There is limited information regarding the effects of spaceflight on the anatomical configuration of the brain and on cerebrospinal fluid (CSF) spaces. We used magnetic resonance imaging (MRI) to compare images of 18 astronauts' brains before and after missions of long duration, involving stays on the International Space Station, and of 16 astronauts' brains before and after missions of short duration, involving participation in the Space Shuttle Program. Images were interpreted by readers who were unaware of the flight duration. We also generated paired preflight and postflight MRI cine clips derived from high-resolution, three-dimensional imaging of 12 astronauts after long-duration flights and from 6 astronauts after short-duration flights in order to assess the extent of narrowing of CSF spaces and the displacement of brain structures. We also compared preflight ventricular volumes with postflight ventricular volumes by means of an automated analysis of T 1 -weighted MRIs. The main prespecified analyses focused on the change in the volume of the central sulcus, the change in the volume of CSF spaces at the vertex, and vertical displacement of the brain. Narrowing of the central sulcus occurred in 17 of 18 astronauts after long-duration flights (mean flight time, 164.8 days) and in 3 of 16 astronauts after short-duration flights (mean flight time, 13.6 days) (P<0.001). Cine clips from a subgroup of astronauts showed an upward shift of the brain after all long-duration flights (12 astronauts) but not after short-duration flights (6 astronauts) and narrowing of CSF spaces at the vertex after all long-duration flights (12 astronauts) and in 1 of 6 astronauts after short-duration flights. Three astronauts in the long-duration group had optic-disk edema, and all 3 had narrowing of the central sulcus. A cine clip was available for 1 of these 3 astronauts, and the cine clip showed upward shift of the brain. Narrowing of the central sulcus, upward shift of the brain, and narrowing of CSF spaces at the vertex occurred frequently and predominantly in astronauts after long-duration flights. Further investigation, including repeated postflight imaging conducted after some time on Earth, is required to determine the duration and clinical significance of these changes. (Funded by the National Aeronautics and Space Administration.).
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKenzie, E; Yang, W; Burnison, M
2014-06-15
Purpose: Patients undergoing radiotherapy (RT) for left-sided breast cancer have increased risk of coronary artery disease. Deep Inhalation Breath Hold assisted RT (DIBH-RT) is shown to increase the geometric separation of the target area and heart, reducing cardiac radiation dose. The purposes of this study are to use Cine MV portal images to determine the stability of spirometer-guided DIBH-RT and examine the dosimetric cardiopulmonary impact of this technique. Methods: Twenty consecutive patients with left-sided breast cancer were recruited to the IRB-approved study. Free-breathing (FB) and DIBH-CT's were acquired at simulation. Rigid registration of the FB-CT and DIBH-CT was performed usingmore » primarily breast tissue. Treatment plans were created for each FB-CT and DIBH-CT using identical paired tangent fields with field-in-field or electronic compensation techniques. Dosimetric evaluation included mean and maximum (Dmax) doses for the left anterior descending artery (LAD), mean heart dose, and left lung V20. Cine MV portal images were acquired for medial and lateral fields during treatment. Analysis of Cine images involved chest wall segmentation using an algorithm developed in-house. Intra- and inter-fractional chest wall motion were determined through affine registration to the first frame of each Cine. Results: Dose to each cardiac structure evaluated was significantly (p<0.001) reduced with the DIBH plans. Mean heart dose decreased from 2.9(0.9–6.6) to 1.6(0.6–5.3) Gy; mean LAD dose from 16.6(3–43.6) to 7.4(1.7–32.7) Gy; and LAD Dmax from 35.4 (6.1–53) to 18.4(2.5–51.2) Gy. No statistically significant reduction was found for the left lung V20. Average AP and SI median chest wall motion (intrafractional) was 0.1 (SD=0.9) and 0.5 (SD=1.1) mm, respectively. Average AP inter-fractional chest wall motion was 2.0 (SD=1.4) mm. Conclusion: Spirometer-based DIBH treatments of the left breast are reproducible both inter- and intra-fractionally, and provide a statistically and potentially clinically useful dosimetric advantage to cardiac structures.« less
Shiina, Yumi; Inai, Kei; Takahashi, Tatsunori; Shimomiya, Yamato; Ishizaki, Umiko; Fukushima, Kenji; Nagao, Michinobu
2018-02-01
We developed a novel imaging technique, designated as vortex flow (VF) mapping, which presents a vortex flow visually on conventional two-dimensional (2D) cine MRI. Using it, we assessed circumferential VF patterns and influences on RA thrombus and supraventricular tachycardia (SVT) in AP connection-type Fontan circulation. Retrospectively, we enrolled 27 consecutive patients (25.1 ± 9.2 years) and 7 age-matched controls who underwent cardiac MRI. Conventional cine images acquired using a 1.5-Tesla scanner were scanned for axial and coronal cross section of the RA. We developed "vortex flow mapping" to demonstrate the ratio of the circumferential voxel movement at each phase to the total movement throughout a cardiac cycle towards the RA center. The maximum ratio was used as a magnitude of vortex flow (MVF%) in RA cine imaging. We also measured percentages of strong and weak VF areas (VFA%). Furthermore, in 10 out of 27, we compared VF between previous CMR (3.8 ± 1.5 years ago) and latest CMR. Of the patients, 15 had cardiovascular complications (Group A); 12 did not (Group B). A transaxial image showed that strong VFA% in Group A was significantly smaller than that in Group B or controls. A coronal view revealed that strong VFA% was also smaller, and weak VFA% was larger in Group A than in Group B or controls (P < 0.05, and P < 0.05). Maximum MVF% in Group A was significantly smaller than in other groups (P < 0.001). Univariate logistic analyses revealed weak VFA% on a coronal image, and serum total bilirubin level as factors affecting cardiovascular complications (Odds ratio 1.14 and 66.1, 95% CI 1.004-1.30 and 1.59-2755.6, P values < 0.05 and < 0.05, respectively). Compared to the previous CMR, smaller maximum VMF%, smaller strong VFA%, and larger weak VFA% were identified in the latest CMR. Circumferentially weak VFA% on a coronal image can be one surrogate marker of SVT and thrombus in AP connection-type Fontan circulation. This simple VF assessment is clinically useful to detect blood stagnation.
Transmission scenarios of major vector-borne diseases in Colombia, 1990-2016.
Padilla, Julio César; Lizarazo, Fredy Eberto; Murillo, Olga Lucía; Mendigaña, Fernando Antonio; Pachón, Edwin; Vera, Mauricio Javier
2017-03-29
Introducción. Las enfermedades transmitidas por vectores representan más de 17 % de todas las enfermedades infecciosas y causan anualmente un millón de defunciones a nivel mundial. En Colombia, la malaria, el dengue, la enfermedad de Chagas y las leishmaniasis son condiciones endemoepidémicas persistentes.Objetivo. Determinar el comportamiento epidemiológico de las enfermedades transmitidas por vectores en zonas urbanas y rurales de Colombia entre 1990 y 2016.Materiales y métodos. Se hizo un estudio descriptivo del comportamiento epidemiológico de las principales enfermedades transmitidas por vectores en zonas urbanas y rurales de Colombia entre 1990 y 2016, con la información proveniente de fuentes oficiales secundarias.Resultados. En el periodo estudiado se registraron 5'360.134 casos de enfermedades transmitidas por vectores, de los cuales 54,7 % fueron de malaria y 24,9 % de dengue. Estos casos concentraron el 80 % de la carga acumulada de casos de enfermedades transmitidas por vectores. Las medianas de las tasas de incidencia fueron 1.371 y 188 por 100.00 habitantes para malaria y dengue, respectivamente. Además, los casos de chikungunya fueron 774.831 desde su introducción en el 2014 y, los de Zika, 117.674 desde su aparición en 2015. En las zonas rurales predominaron las enfermedades parasitarias transmitidas por vectores como la malaria, las leishmaniasis y la enfermedad de Chagas. A nivel urbano, predominaron el dengue, el chikungunya y el Zika.Conclusiones. La transmisión en Colombia de estas enfermedades es persistente en las zonas urbanas y en las rurales, y de tipo endemoepidémico en los casos de malaria, dengue, leishmaniasis y enfermedad de Chagas. Dicha transmisión se ha dado de manera focalizada y con patrones variables de intensidad. Asimismo, se mantienen las condiciones que han favorecido la transmisión emergente de nuevas arbovirosis.
Kampik, A; Rapp, J
1979-02-01
A method of Cinematography of the ocular fundus is introduced which--by connecting a camera with an indirect ophthalmoscop--allows to record the monocular picture of the fundus as produced by the ophthalmic lens.
The effect of respiratory induced density variations on non-TOF PET quantitation in the lung.
Holman, Beverley F; Cuplov, Vesna; Hutton, Brian F; Groves, Ashley M; Thielemans, Kris
2016-04-21
Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant (18)F-FDG and (18)F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung.
Gulsin, Gaurav S; Shetye, Abishek; Khoo, Jeffrey; Swarbrick, Daniel J; Levelt, Eylem; Lai, Florence Y; Squire, Iain B; Arnold, Jayanth R; McCann, Gerry P
2017-04-08
Late gadolinium enhanced cardiovascular magnetic resonance (LGE-CMR) has excellent specificity, sensitivity and diagnostic accuracy for differentiating between ischemic cardiomyopathy (ICM) and non-ischemic dilated cardiomyopathy (NICM). CMR first-pass myocardial perfusion imaging (perfusion-CMR) may also play role in distinguishing heart failure of ischemic and non-ischemic origins, although the utility of additional of stress perfusion imaging in such patients is unclear. The aim of this retrospective study was to assess whether the addition of adenosine stress perfusion imaging to LGE-CMR is of incremental value for differentiating ICM and NICM in patients with severe left ventricular systolic dysfunction (LVSD) of uncertain etiology. We retrospectively identified 100 consecutive adult patients (median age 69 years (IQR 59-73)) with severe LVSD (mean LV EF 26.6 ± 7.0%) referred for perfusion-CMR to establish the underlying etiology of heart failure. The cause of heart failure was first determined on examination of CMR cine and LGE images in isolation. Subsequent examination of complete adenosine stress perfusion-CMR studies (cine, LGE and perfusion images) was performed to identify whether this altered the initial diagnosis. On LGE-CMR, 38 patients were diagnosed with ICM, 46 with NICM and 16 with dual pathology. With perfusion-CMR, there were 39 ICM, 44 NICM and 17 dual pathology diagnoses. There was excellent agreement in diagnoses between LGE-CMR and perfusion-CMR (κ 0.968, p<0.001). The addition of adenosine stress perfusion images to LGE-CMR altered the diagnosis in only two of the 100 patients. The addition of adenosine stress perfusion-CMR to cine and LGE-CMR provides minimal incremental diagnostic yield for determining the etiology of heart failure in patients with severe LVSD.
2011-01-01
Background Quantitative noninvasive imaging of myocardial mechanics in mice enables studies of the roles of individual genes in cardiac function. We sought to develop comprehensive three-dimensional methods for imaging myocardial mechanics in mice. Methods A 3D cine DENSE pulse sequence was implemented on a 7T small-bore scanner. The sequence used three-point phase cycling for artifact suppression and a stack-of-spirals k-space trajectory for efficient data acquisition. A semi-automatic 2D method was adapted for 3D image segmentation, and automated 3D methods to calculate strain, twist, and torsion were employed. A scan protocol that covered the majority of the left ventricle in a scan time of less than 25 minutes was developed, and seven healthy C57Bl/6 mice were studied. Results Using these methods, multiphase normal and shear strains were measured, as were myocardial twist and torsion. Peak end-systolic values for the normal strains at the mid-ventricular level were 0.29 ± 0.17, -0.13 ± 0.03, and -0.18 ± 0.14 for Err, Ecc, and Ell, respectively. Peak end-systolic values for the shear strains were 0.00 ± 0.08, 0.04 ± 0.12, and 0.03 ± 0.07 for Erc, Erl, and Ecl, respectively. The peak end-systolic normalized torsion was 5.6 ± 0.9°. Conclusions Using a 3D cine DENSE sequence tailored for cardiac imaging in mice at 7 T, a comprehensive assessment of 3D myocardial mechanics can be achieved with a scan time of less than 25 minutes and an image analysis time of approximately 1 hour. PMID:22208954
Moro, Pierre-Julien; Flavian, Antonin; Jacquier, Alexis; Kober, Frank; Quilici, Jacques; Gaborit, Bénédicte; Bonnet, Jean-Louis; Moulin, Guy; Cozzone, Patrick J; Bernard, Monique
2011-09-23
Gender-specific differences in cardiovascular risk are well known, and current evidence supports an existing role of endothelium in these differences. The purpose of this study was to assess non invasively coronary endothelial function in male and female young volunteers by myocardial blood flow (MBF) measurement using coronary sinus (CS) flow quantification by velocity encoded cine cardiovascular magnetic resonance (CMR) at rest and during cold pressor test (CPT). Twenty-four healthy volunteers (12 men, 12 women) underwent CMR in a 3 Tesla MR imager. Coronary sinus flow was measured at rest and during CPT using non breath-hold velocity encoded phase contrast cine-CMR. Myocardial function and morphology were acquired using a cine steady-state free precession sequence. At baseline, mean MBF was 0.63 ± 0.23 mL·g⁻¹·min⁻¹ in men and 0.79 ± 0.21 mL·g⁻¹·min⁻¹ in women. During CPT, the rate pressure product in men significantly increased by 49 ± 36% (p < 0.0001) and in women by 52 ± 22% (p < 0.0001). MBF increased significantly in both men and women by 0.22 ± 0.19 mL·g⁻¹·min⁻¹ (p = 0.0022) and by 0.73 ± 0.43 mL·g⁻¹·min⁻¹ (p = 0.0001), respectively. The increase in MBF was significantly higher in women than in men (p = 0.0012). CMR coronary sinus flow quantification for measuring myocardial blood flow revealed a higher response of MBF to CPT in women than in men. This finding may reflect gender differences in endothelial-dependent vasodilatation in these young subjects. This non invasive rest/stress protocol may become helpful to study endothelial function in normal physiology and in physiopathology.
The effect of respiratory induced density variations on non-TOF PET quantitation in the lung
NASA Astrophysics Data System (ADS)
Holman, Beverley F.; Cuplov, Vesna; Hutton, Brian F.; Groves, Ashley M.; Thielemans, Kris
2016-04-01
Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant 18F-FDG and 18F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung.
Dynamic Ultrasonography of the Deep External Rotator Musculature of the Hip: A Descriptive Study.
Battaglia, Patrick J; Mattox, Ross; Haun, Daniel W; Welk, Aaron B; Kettner, Norman W
2016-07-01
No detailed reports exist describing the methodology of ultrasound image acquisition of the deep external rotator muscles of the hip. Because gluteal pain and sciatica are common, ultrasound may be a useful dynamic imaging adjunct in the evaluation of these patients. To describe dynamic ultrasonography of the deep external rotator muscles of the hip for diagnostic purposes. Descriptive. University radiology department. Participants (n = 25; 14 male) without gluteal pain or sciatica were enrolled (mean age 27.6 ± 4.7 years; mean body mass index 26.0 ± 4.1 kg/m(2)). Ultrasonographic cine clips oriented to the long axis of each deep external rotator muscle were captured. In addition, cine clips of the piriformis tendon and obturator internus tendon were obtained. Cine clips were analyzed approximately 1 week after completion of image acquisition independently by 2 blinded raters. A 5-point Likert scale to evaluate the diagnostic utility of the ultrasound image. The modal Likert scores for rater 1 were as follows: piriformis muscle = 4; piriformis tendon = 4; superior gemellus muscle = 3; obturator internus muscle = 4; obturator internus tendon = 4; inferior gemellus muscle = 4; quadratus femoris muscle = 4. The modal scores for rater 2 were: piriformis muscle = 4; piriformis tendon = 3; superior gemellus muscle = 4; obturator internus muscle = 3; obturator internus tendon = 4; inferior gemellus muscle = 3; quadratus femoris muscle = 4. Dynamic ultrasonography may be useful to image the hip deep external rotator musculature for diagnostic purposes and therefore aid in the evaluation of gluteal pain and sciatica. Future work should investigate the reliability and validity of ultrasonography in the evaluation of pathology of these muscles. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Ishizaki, Umiko; Nagao, Michinobu; Shiina, Yumi; Fukushima, Kenji; Takahashi, Tatsunori; Shimomiya, Yamato; Matsuo, Yuka; Inai, Kei; Sakai, Shuji
2018-05-18
Long-term hepatic dysfunction is an increasingly recognized complication of the Fontan operation for univentricular hearts. The purpose of this study was to determine whether Fontan-associated liver disease (FALD) could be predicted by flow dynamics in the right atrium (RA) of Fontan circulation.Methods and Results:Cardiac MRI and the serum levels of total bilirubin (TBil) and hyaluronic acid (HA) were analyzed in 36 patients who underwent an atriopulmonary connection type of Fontan operation. The mean follow-up period was 53 months. Three views (axial, coronal, and sagittal) of the cine images were scanned for the maximum cross-section of the RA obtained with1.5-Tesla scanner. We developed a "vortex flow map" to demonstrate the ratio of the circumferential voxel movement in each phase to the total movement throughout a cardiac cycle towards the center of the RA. The maximum ratio was used as the magnitude of vortex flow (MVF%) in the 3 views of the RA cine imaging. Patients with coronal MVF ≥13.6% had significantly lower free rates of TBil ≥1.8 mg/dL than those with coronal MVF <13.6% (log-rank value=4.50; P<0.05; hazard ratio=4.54). Patients with sagittal MVF ≥14.0% had significantly lower free rates of HA ≥50 ng/mL than those with coronal MVF <14.0% (log-rank value=4.40; P<0.05; hazard ratio=4.12). A reduced vortex flow in the RA during the late phase of the Fontan operation was associated with the development of FALD. MVF can be used as an imaging biomarker to predict FALD.
Fischbach, Katharina; Kosiek, Otrud; Friebe, Björn; Wybranski, Christian; Schnackenburg, Bernhard; Schmeisser, Alexander; Smid, Jan; Ricke, Jens; Pech, Maciej
2017-01-01
Cardiac magnetic resonance imaging (cMRI) has become the non-invasive reference standard for the evaluation of cardiac function and viability. The introduction of open, high-field, 1.0T (HFO) MR scanners offers advantages for examinations of obese, claustrophobic and paediatric patients.The aim of our study was to compare standard cMRI sequences from an HFO scanner and those from a cylindrical, 1.5T MR system. Fifteen volunteers underwent cMRI both in an open HFO and in a cylindrical MR system. The protocol consisted of cine and unenhanced tissue sequences. The signal-to-noise ratio (SNR) for each sequence and blood-myocardium contrast for the cine sequences were assessed. Image quality and artefacts were rated. The location and number of non-diagnostic segments was determined. Volunteers' tolerance to examinations in both scanners was investigated. SNR was significantly lower in the HFO scanner (all p<0.001). However, the contrast of the cine sequence was significantly higher in the HFO platform compared to the 1.5T MR scanner (0.685±0.41 vs. 0.611±0.54; p<0.001). Image quality was comparable for all sequences (all p>0.05). Overall, only few non-diagnostic myocardial segments were recorded: 6/960 (0.6%) by the HFO and 17/960 (1.8%) segments by the cylindrical system. The volunteers expressed a preference for the open MR system (p<0.01). Standard cardiac MRI sequences in an HFO platform offer a high image quality that is comparable to the quality of images acquired in a cylindrical 1.5T MR scanner. An open scanner design may potentially improve tolerance of cardiac MRI and therefore allow to examine an even broader patient spectrum.
Analysis of speech and tongue motion in normal and post-glossectomy speaker using cine MRI.
Ha, Jinhee; Sung, Iel-Yong; Son, Jang-Ho; Stone, Maureen; Ord, Robert; Cho, Yeong-Cheol
2016-01-01
Since the tongue is the oral structure responsible for mastication, pronunciation, and swallowing functions, patients who undergo glossectomy can be affected in various aspects of these functions. The vowel /i/ uses the tongue shape, whereas /u/ uses tongue and lip shapes. The purpose of this study is to investigate the morphological changes of the tongue and the adaptation of pronunciation using cine MRI for speech of patients who undergo glossectomy. Twenty-three controls (11 males and 12 females) and 13 patients (eight males and five females) volunteered to participate in the experiment. The patients underwent glossectomy surgery for T1 or T2 lateral lingual tumors. The speech tasks "a souk" and "a geese" were spoken by all subjects providing data for the vowels /u/ and /i/. Cine MRI and speech acoustics were recorded and measured to compare the changes in the tongue with vowel acoustics after surgery. 2D measurements were made of the interlip distance, tongue-palate distance, tongue position (anterior-posterior and superior-inferior), tongue height on the left and right sides, and pharynx size. Vowel formants Fl, F2, and F3 were measured. The patients had significantly lower F2/Fl ratios (F=5.911, p=0.018), and lower F3/F1 ratios that approached significance. This was seen primarily in the /u/ data. Patients had flatter tongue shapes than controls with a greater effect seen in /u/ than /i/. The patients showed complex adaptation motion in order to preserve the acoustic integrity of the vowels, and the tongue modified cavity size relationships to maintain the value of the formant frequencies.
Assessment by airway ellipticity on cine-MRI to differentiate severe obstructive sleep apnea.
Kojima, Tsukasa; Kawakubo, Masateru; Nishizaka, Mari K; Rahmawati, Anita; Ando, Shin-Ichi; Chishaki, Akiko; Nakamura, Yasuhiko; Nagao, Michinobu
2018-03-01
The severity of obstructive sleep apnea (OSA) is assessed by the apnea-hypopnea index (AHI) determined from polysomnography (PSG). However, PSG requires a specialized facility with well-trained specialists and takes overnight. Therefore, simple tools, which could distinguish severe OSA, have been needed before performing PSG. We propose the new index using cine-MRI as a screening test to differentiate severe OSA patients, who would need PSG and proper treatment. Thirty-six patients with suspected OSA (mean age 54.6 y, mean AHI 52.6 events/h, 33 males) underwent airway cine-MRI at the fourth cervical vertebra level during 30 s of free breathing and PSG. The minimum airway ellipticity (AE) in 30 s duration was measured, and was defined as the severity of OSA. Patients were divided into severe OSA, not-severe OSA, and normal groups, according to PSG results. The comparison of AE between any two of the three groups was performed by Wilcoxon rank-sum test. Receiver operating characteristic (ROC) curve analysis was performed to determine the optimal cut-off of AE for identifying severe OSA patients. The minimum AE for severe OSA was significantly lower than that for not-severe OSA and normal (severe, 0.17 ± 0.16; not severe, 0.31 ± 0.17; normal, 0.38 ± 0.19, P < .05). ROC analysis revealed that the optimal cutoff of the minimum AE 0.21 identified severe OSA patients, with an area under the curve of 0.75, 68% sensitivity, and 83% specificity. AE is a feasible quantitative index, and a promising screening test for detecting severe OSA patients. © 2016 John Wiley & Sons Ltd.
Borotikar, Bhushan S; Sipprell, William H; Wible, Emily E; Sheehan, Frances T
2012-04-05
Patellofemoral osteoarthritis and its potential precursor patellofemoral pain syndrome (PFPS) are common, costly, and debilitating diseases. PFPS has been shown to be associated with altered patellofemoral joint mechanics; however, an actual variation in joint contact stresses has not been established due to challenges in accurately quantifying in vivo contact kinematics (area and location). This study developed and validated a method for tracking dynamic, in vivo cartilage contact kinematics by combining three magnetic resonance imaging (MRI) techniques, cine-phase contrast (CPC), multi-plane cine (MPC), and 3D high-resolution static imaging. CPC and MPC data were acquired from 12 healthy volunteers while they actively extended/flexed their knee within the MRI scanner. Since no gold standard exists for the quantification of in vivo dynamic cartilage contact kinematics, the accuracy of tracking a single point (patellar origin relative to the femur) represented the accuracy of tracking the kinematics of an entire surface. The accuracy was determined by the average absolute error between the PF kinematics derived through registration of MPC images to a static model and those derived through integration of the CPC velocity data. The accuracy ranged from 0.47 mm to 0.77 mm for the patella and femur and from 0.68 mm to 0.86 mm for the patellofemoral joint. For purely quantifying joint kinematics, CPC remains an analytically simpler and more accurate (accuracy <0.33 mm) technique. However, for application requiring the tracking of an entire surface, such as quantifying cartilage contact kinematics, this combined imaging approach produces accurate results with minimal operator intervention. Published by Elsevier Ltd.
Vandsburger, Moriel; Vandoorne, Katrien; Oren, Roni; Leftin, Avigdor; Mpofu, Senzeni; Delli Castelli, Daniela; Aime, Silvio; Neeman, Michal
2015-01-01
Application of emerging molecular MRI techniques, including chemical exchange saturation transfer (CEST)-MRI, to cardiac imaging is desirable; however, conventional methods are poorly suited for cardiac imaging, particularly in small animals with rapid heart rates. We developed a CEST-encoded steady state and retrospectively gated cardiac cine imaging sequence in which the presence of fibrosis or paraCEST contrast agents was directly encoded into the steady-state myocardial signal intensity (cardioCEST). Development of cardioCEST: A CEST-encoded cardiac cine MRI sequence was implemented on a 9.4T small animal scanner. CardioCEST of fibrosis was serially performed by acquisition of a series of CEST-encoded cine images at multiple offset frequencies in mice (n=7) after surgically induced myocardial infarction. Scar formation was quantified using a spectral modeling approach and confirmed with histological staining. Separately, circulatory redistribution kinetics of the paramagnetic CEST agent Eu-HPDO3A were probed in mice using cardioCEST imaging, revealing rapid myocardial redistribution, and washout within 30 minutes (n=6). Manipulation of vascular tone resulted in heightened peak CEST contrast in the heart, but did not alter redistribution kinetics (n=6). At 28 days after myocardial infarction (n=3), CEST contrast kinetics in infarct zone tissue were altered, demonstrating gradual accumulation of Eu-HPDO3A in the increased extracellular space. cardioCEST MRI enables in vivo imaging of myocardial fibrosis using endogenous contrast mechanisms, and of exogenously delivered paraCEST agents, and can enable multiplexed imaging of multiple molecular targets at high-resolution coupled with conventional cardiac MRI scans. © 2013 American Heart Association, Inc.
PisCES: Pis(cine) Community Estimation Software
PisCES predicts a fish community for any NHD-Plus stream reach in the conterminous United States. PisCES utilizes HUC-based distributional information for over 1,000 nature and non-native species obtained from NatureServe, the USGS, and Peterson Field Guide to Freshwater Fishes o...
Colour stereociné photography with twin cameras through the operation microscope.
Phillips, C I; McDonald, A J
1975-01-01
Two Beaulieu R16 cinecameras attached toa Zeiss operation microscope, OP Mi2, one for each side, produced colour cine films. When these were projected through polarizing filters on to a silver screen, the audience (wearing appropriately oriented polarizing spectacles) achieved a stereoscopic view.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Juan; School of Information Science and Engineering, Shandong University, Jinan, Shandong; Cai, Jing
Purpose: To evaluate the feasibility of a retrospective binning technique for 4-dimensional magnetic resonance imaging (4D-MRI) using body area (BA) as a respiratory surrogate. Methods and Materials: Seven patients with hepatocellular carcinoma (4 of 7) or liver metastases (3 of 7) were enrolled in an institutional review board-approved prospective study. All patients were simulated with both computed tomography (CT) and MRI to acquire 3-dimensinal and 4D images for treatment planning. Multiple-slice multiple-phase cine-MR images were acquired in the axial plane for 4D-MRI reconstruction. Image acquisition time per slice was set to 10-15 seconds. Single-slice 2-dimensinal cine-MR images were also acquiredmore » across the center of the tumor in orthogonal planes. Tumor motion trajectories from 4D-MRI, cine-MRI, and 4D-CT were analyzed in the superior–inferior (SI), anterior–posterior (AP), and medial–lateral (ML) directions, respectively. Their correlation coefficients (CC) and differences in tumor motion amplitude were determined. Tumor-to-liver contrast-to-noise ratio (CNR) was measured and compared between 4D-CT, 4D-MRI, and conventional T2-weighted fast spin echo MRI. Results: The means (±standard deviations) of CC comparing 4D-MRI with cine-MRI were 0.97 ± 0.03, 0.97 ± 0.02, and 0.99 ± 0.04 in SI, AP, and ML directions, respectively. The mean differences were 0.61 ± 0.17 mm, 0.32 ± 0.17 mm, and 0.14 ± 0.06 mm in SI, AP, and ML directions, respectively. The means of CC comparing 4D-MRI and 4D-CT were 0.95 ± 0.02, 0.94 ± 0.02, and 0.96 ± 0.02 in SI, AP, and ML directions, respectively. The mean differences were 0.74 ± 0.02 mm, 0.33 ± 0.13 mm, and 0.18 ± 0.07 mm in SI, AP, and ML directions, respectively. The mean tumor-to-tissue CNRs were 2.94 ± 1.51, 19.44 ± 14.63, and 39.47 ± 20.81 in 4D-CT, 4D-MRI, and T2-weighted MRI, respectively. Conclusions: The preliminary evaluation of our 4D-MRI technique results in oncologic patients demonstrates its potential usefulness to accurately measure tumor respiratory motion with improved tumor CNR compared with 4D-CT.« less
Trotier, Aurélien J; Lefrançois, William; Van Renterghem, Kris; Franconi, Jean-Michel; Thiaudière, Eric; Miraux, Sylvain
2015-07-07
To show that 3D sequences with ultra-short echo times (UTEs) can generate a positive contrast whatever the magnetic field (4.7, 7 or 9.4 T) and whatever Ultra Small Particles of Iron Oxide (USPIO) concentration injected and to use it for 3D time-resolved imaging of the murine cardiovascular system with high spatial and temporal resolutions. Three different concentrations (50, 200 and 500 μmol Fe/kg) of USPIO were injected in mice and static images of the middle part of the animals were acquired at 4.7, 7 and 9.4 T pre and post-contrast with UTE (TE/TR = 0.05/4.5 ms) sequences. Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) of blood and static tissus were evaluated before and after contrast agent injection. 3D-cine images (TE/TR = 0.05/3.5 ms, scan time < 12 min) at 156 μm isotropic resolution of the mouse cardiopulmonary system were acquired prospectively with the UTE sequence for the three magnetic fields and with an USPIO dose of 200 μmol Fe/kg. SNR, CNR and signal homogeneity of blood were measured. High spatial (104 μm) or temporal (3.5 ms) resolution 3D-cine imaging (scan time < 35 min) isotropic resolution were also performed at 7 T with a new sequence encoding scheme. UTE imaging generated positive contrast and higher SNR and CNR whatever the magnetic field and the USPIO concentration used compared to pre-contrast images. Time-resolved 3D acquisition enables high blood SNR (66.6 ± 4.5 at 7 T) and CNR (33.2 ± 4.2 at 7 T) without flow or motion artefact. Coronary arteries and aortic valve were visible on images acquired at 104 μm resolution. We have demonstrated that by combining the injection of iron nanoparticles with 3D-cine UTE sequences, it was possible to generate a strong positive contrast between blood and surrounding tissues. These properties were exploited to produce images of the cardiovascular system in small animals at high magnetic fields with a high spatial and temporal resolution. This approach might be useful to measure the functional cardiac parameters or to assess anatomical modifications to the blood vessels in cardio-vascular disease models.
Xu, Jian; Kim, Daniel; Otazo, Ricardo; Srichai, Monvadi B; Lim, Ruth P; Axel, Leon; Mcgorty, Kelly Anne; Niendorf, Thoralf; Sodickson, Daniel K
2013-07-01
To evaluate the feasibility and perform initial comparative evaluations of a 5-minute comprehensive whole-heart magnetic resonance imaging (MRI) protocol with four image acquisition types: perfusion (PERF), function (CINE), coronary artery imaging (CAI), and late gadolinium enhancement (LGE). This study protocol was Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board-approved. A 5-minute comprehensive whole-heart MRI examination protocol (Accelerated) using 6-8-fold-accelerated volumetric parallel imaging was incorporated into and compared with a standard 2D clinical routine protocol (Standard). Following informed consent, 20 patients were imaged with both protocols. Datasets were reviewed for image quality using a 5-point Likert scale (0 = non-diagnostic, 4 = excellent) in blinded fashion by two readers. Good image quality with full whole-heart coverage was achieved using the accelerated protocol, particularly for CAI, although significant degradations in quality, as compared with traditional lengthy examinations, were observed for the other image types. Mean total scan time was significantly lower for the Accelerated as compared to Standard protocols (28.99 ± 4.59 min vs. 1.82 ± 0.05 min, P < 0.05). Overall image quality for the Standard vs. Accelerated protocol was 3.67 ± 0.29 vs. 1.5 ± 0.51 (P < 0.005) for PERF, 3.48 ± 0.64 vs. 2.6 ± 0.68 (P < 0.005) for CINE, 2.35 ± 1.01 vs. 2.48 ± 0.68 (P = 0.75) for CAI, and 3.67 ± 0.42 vs. 2.67 ± 0.84 (P < 0.005) for LGE. Diagnostic image quality for Standard vs. Accelerated protocols was 20/20 (100%) vs. 10/20 (50%) for PERF, 20/20 (100%) vs. 18/20 (90%) for CINE, 18/20 (90%) vs. 18/20 (90%) for CAI, and 20/20 (100%) vs. 18/20 (90%) for LGE. This study demonstrates the technical feasibility and promising image quality of 5-minute comprehensive whole-heart cardiac examinations, with simplified scan prescription and high spatial and temporal resolution enabled by highly parallel imaging technology. The study also highlights technical hurdles that remain to be addressed. Although image quality remained diagnostic for most scan types, the reduced image quality of PERF, CINE, and LGE scans in the Accelerated protocol remain a concern. Copyright © 2012 Wiley Periodicals, Inc.
Real-time automatic fiducial marker tracking in low contrast cine-MV images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Wei-Yang; Lin, Shu-Fang; Yang, Sheng-Chang
2013-01-15
Purpose: To develop a real-time automatic method for tracking implanted radiographic markers in low-contrast cine-MV patient images used in image-guided radiation therapy (IGRT). Methods: Intrafraction motion tracking using radiotherapy beam-line MV images have gained some attention recently in IGRT because no additional imaging dose is introduced. However, MV images have much lower contrast than kV images, therefore a robust and automatic algorithm for marker detection in MV images is a prerequisite. Previous marker detection methods are all based on template matching or its derivatives. Template matching needs to match object shape that changes significantly for different implantation and projection angle.more » While these methods require a large number of templates to cover various situations, they are often forced to use a smaller number of templates to reduce the computation load because their methods all require exhaustive search in the region of interest. The authors solve this problem by synergetic use of modern but well-tested computer vision and artificial intelligence techniques; specifically the authors detect implanted markers utilizing discriminant analysis for initialization and use mean-shift feature space analysis for sequential tracking. This novel approach avoids exhaustive search by exploiting the temporal correlation between consecutive frames and makes it possible to perform more sophisticated detection at the beginning to improve the accuracy, followed by ultrafast sequential tracking after the initialization. The method was evaluated and validated using 1149 cine-MV images from two prostate IGRT patients and compared with manual marker detection results from six researchers. The average of the manual detection results is considered as the ground truth for comparisons. Results: The average root-mean-square errors of our real-time automatic tracking method from the ground truth are 1.9 and 2.1 pixels for the two patients (0.26 mm/pixel). The standard deviations of the results from the 6 researchers are 2.3 and 2.6 pixels. The proposed framework takes about 128 ms to detect four markers in the first MV images and about 23 ms to track these markers in each of the subsequent images. Conclusions: The unified framework for tracking of multiple markers presented here can achieve marker detection accuracy similar to manual detection even in low-contrast cine-MV images. It can cope with shape deformations of fiducial markers at different gantry angles. The fast processing speed reduces the image processing portion of the system latency, therefore can improve the performance of real-time motion compensation.« less
Presentación del estudio “Links” de hombres que tienes sexo con hombres en Buenos Aires, Argentina
Carballo-Diéguez, Alex; Ávila, María M; Balán, Iván C.; Marone, Rubén; Pando, María A.; Barreda, Victoria
2011-01-01
Resumen Estudios previos en Buenos Aires reportaron altas prevalencias de HIV entre HSH, con valores que oscilan entre 9 y 14% durante casi 10 años de continuo testeo. El objetivo principal de este estudio fue la evaluación de factores relacionados al comportamiento de alto riesgo para transmisión del HIV entre HSH entre los que se incluyen el conocimiento y factores emocionales, socioculturales y ambientales. Por otro lado se realizó la estimación de prevalencia e incidencia de HIV utilizando RDS (Respondent Driven Sampling), así como la presencia de otras infecciones de transmisión sexual. Por último se evaluaron los hábitos de testeo para HIV indagando que factores facilitan o impiden su realización. El estudio constó de dos fases, en primer lugar una fase cualitativa y posteriormente una fase cuantitativa con una duración total de 4 años y medio. Durante la fase cualitativa se realizaron 44 entrevistas individuales en profundidad, 8 grupos focales y 10 observaciones etnográficas (hoteles, baños públicos (“teteras”), cines pornográficos, fiestas privadas, dark rooms y discotecas). Durante la fase cuantitativa del estudio se realizó el reclutamiento de 500 participantes que provinieron de la Ciudad Autónoma de Buenos Aires, así como del Gran Buenos Aires. El reclutamiento se comenzó con 16 participantes llamados semillas. Se realizó el diagnóstico de infección por HIV, hepatitis B y C (HBV y HCV), Treponema pallidum, Virus Papiloma Humano (HPV) y Chlamidias. La colaboración establecida entre los grupos de trabajo enfocados en áreas diversas posibilitó el abordaje conjunto de nuevas estrategias de investigación antes no exploradas en nuestro país. Los resultados más relevantes de esta investigación serán progresivamente publicados en sucesivos números de Actualizaciones en SIDA. PMID:25264397
Nacif, Marcelo S; Almeida, Andre L C; Young, Alistair A; Cowan, Brett R; Armstrong, Anderson C; Yang, Eunice; Sibley, Christopher T; Hundley, W Gregory; Liu, Songtao; Lima, Joao Ac; Bluemke, David A
2017-01-01
Cardiac Magnetic Resonance is in need of a simple and robust method for diastolic function assessment that can be done with routine protocol sequences. To develop and validate a three-dimensional (3D) model-based volumetric assessment of diastolic function using cardiac magnetic resonance (CMR) imaging and compare the results obtained with the model with those obtained by echocardiography. The study participants provided written informed consent and were included if having undergone both echocardiography and cine steady-state free precession (SSFP) CMR on the same day. Guide points at the septal and lateral mitral annulus were used to define the early longitudinal relaxation rate (E'), while a time-volume curve from the 3D model was used to assess diastolic filling parameters. We determined the correlation between 3D CMR and echocardiography and the accuracy of CMR in classifying the diastolic function grade. The study included 102 subjects. The E/A ratio by CMR was positively associated with the E/A ratio by echocardiography (r = 0.71, p < 0.0001). The early diastolic relaxation velocity by tissue Doppler and longitudinal relaxation rate for the lateral mitral annulus displacement were positively associated (p = 0.007), as were the ratio between Doppler E/e' and CMR E/E' (p = 0.01). CMR-determined normalized peak E (NE) and deceleration time (DT) were able to predict diastolic dysfunction (areas under the curve [AUCs] = 0.70 and 0.72, respectively). In addition, the lateral E/E' ratio showed good utility in identifying diastolic dysfunction (AUC = 0.80). Overall, echocardiography and CMR interobserver and intraobserver agreements were excellent (intraclass correlation coefficient range 0.72 - 0.97). 3D modeling of standard cine CMR images was able to identify study subjects with reduced diastolic function and showed good reproducibility, suggesting a potential for a routine diastolic function assessment by CMR. A ressonância magnética cardíaca necessita de um método simples e robusto para a avaliação da função diastólica que pode ser feito com sequências protocolares de rotina. Desenvolver e validar a avaliação volumétrica da função diastólica através de um modelo tridimensional (3D) com utilização de imagens de ressonância magnética cardíaca (RMC) e comparar os resultados obtidos com este modelo com os obtidos por ecocardiografia. Os participantes do estudo assinaram um termo de consentimento e foram incluídos se tivessem sido submetidos no mesmo dia tanto à ecocardiografia quanto à cine RMC com precessão livre no estado estacionário (steady-state free precession, SSFP). Pontos-guia foram utilizados no anel mitral septal e lateral para definir a velocidade de estiramento no início da diástole (E'), enquanto curvas de volume-tempo do modelo 3D foram utilizadas para avaliar os parâmetros de enchimento diastólico. Foram determinadas a correlação entre a RMC 3D e a ecocardiografia, além da acurácia da RMC em classificar o grau de função diastólica. Ao todo, 102 sujeitos foram incluídos no estudo. A razão E/A pela RMC esteve positivamente associada com a razão E/A obtida pela ecocardiografia (r = 0,71, p < 0,0001). Estiveram positivamente associadas a velocidade de relaxamento diastólico inicial ao Doppler tecidual e a velocidade de relaxamento longitudinal de deslocamento do anel mitral lateral (p = 0,007), bem como a razão entre E/e' por Doppler e E/E' pela RMC (p = 0,01). A velocidade normalizada de pico de enchimento (EM) determinada pela RMC e o tempo de desaceleração (TD) foram capazes de predizer a disfunção diastólica (áreas sob a curva [AUCs] = 0,70 e 0,72, respectivamente). Além disso, a razão E/E' lateral mostrou boa utilidade para a identificação da disfunção diastólica (AUC = 0,80). No geral, a ecocardiografia e a RMC apresentaram excelente concordância interobservador e intraobservador (coeficiente de correlação intraclasse 0,72 - 0,97). Uma modelagem 3D de imagens padrões de cine RMC foi capaz de identificar os indivíduos do estudo com função diastólica reduzida e mostrou uma boa reprodutibilidade, sugerindo ter potencial na avaliação rotineira da função diastólica por RMC.
DC drive system for cine/pulse cameras
NASA Technical Reports Server (NTRS)
Gerlach, R. H.; Sharpsteen, J. T.; Solheim, C. D.; Stoap, L. J.
1977-01-01
Camera-drive functions are separated mechanically into two groups which are driven by two separate dc brushless motors. First motor, a 90 deg stepper, drives rotating shutter; second electronically commutated motor drives claw and film transport. Shutter is made of one piece but has two openings for slow and fast exposures.
Automated Quantitation of Non-Steady Flow and Lumen Area Based on Temporal Correlation
2001-10-25
elevated intracranial pressure (ICP)), and Chiari malformation (herniation of hindbrain into the spinal canal) (3,4). Recently, noninvasive method...4] Pujol J, Roig C, et. al.: Motion of the Cerebellar Tonsils in Chiari Type I Malformation Studied by Cine Phase-Contrast MRI, Neurology 45
Riddle, P N
1990-01-01
Cinematography commenced as a scientific technique used as a system for "slowing down" observed movement. Marey in 1888 (1) constructed, following a number of other ideas, a "Chambre Chronophoto-graphique," which had practically all the elements of the modern cine camera. With this he made serial photographs (not transparencies) of various biological phenomena (2).
Uellendahl, Marly; Siqueira, Maria Eduarda Menezes de; Calado, Eveline Barros; Kalil-Filho, Roberto; Sobral, Dário; Ribeiro, Clébia; Oliveira, Wilson; Martins, Silvia; Narula, Jagat; Rochitte, Carlos Eduardo
2016-11-01
Chagas disease (CD) is an important cause of heart failure and mortality, mainly in Latin America. This study evaluated the morphological and functional characteristics of the heart as well the extent of myocardial fibrosis (MF) in patients with CD by cardiac magnetic resonance (CMR). The prognostic value of MF evaluated by myocardial-delayed enhancement (MDE) was compared with that via Rassi score. This study assessed 39 patients divided into 2 groups: 28 asymptomatic patients as indeterminate form group (IND); and symptomatic patients as Chagas Heart Disease (CHD) group. All patients underwent CMR using the techniques of cine-MRI and MDE, and the amount of MF was compared with the Rassi score. Regarding the morphological and functional analysis, significant differences were observed between both groups (p < 0.001). Furthermore, there was a strong correlation between the extent of MF and the Rassi score (r = 0.76). CMR is an important technique for evaluating patients with CD, stressing morphological and functional differences in all clinical presentations. The strong correlation with the Rassi score and the extent of MF detected by CMR emphasizes its role in the prognostic stratification of patients with CD. A doença de Chagas (DC) é importante causa de insuficiência cardíaca e mortalidade, principalmente na América Latina. Este estudo avaliou as características morfológicas e funcionais do coração, assim como a extensão da fibrose miocárdica (FM) em pacientes com DC através de ressonância magnética cardíaca (RMC). O valor prognóstico da FM avaliada por realce tardio miocárdico (RTM) foi comparado àquele do escore de Rassi. Avaliação de 39 pacientes divididos em 2 grupos: grupo 'forma indeterminada' (IND), 28 pacientes assintomáticos; e grupo 'cardiopatia chagásica' (CC), pacientes sintomáticos. Todos os pacientes foram submetidos a RMC com as técnicas de cine-RM e RTM, sendo a quantidade de FM evidenciada ao exame comparada ao escore de Rassi. As análises morfológica e funcional mostraram significativas diferenças entre os 2 grupos (p < 0,001). Houve ainda uma forte correlação entre a extensão da FM e o escore de Rassi (r = 0,76). A RMC é uma importante técnica para avaliar pacientes com DC, ressaltando as diferenças morfológicas e funcionais em todas as apresentações clínicas. A forte correlação entre o escore de Rassi e a extensão da FM detectada por RMC enfatiza seu papel na estratificação prognóstica de pacientes com DC.
Analysis of Life-Saving Interventions Performed by Out-of-Hospital Combat Medical Personnel
2011-07-01
emergency medicine physician assistants who completed a formal 1-year fellowship in emergency medi- cine ). Combat medics certified as National...war on terror 2001–2004. Ann Surg. 2007;245:986–991. 3. Kelly JF, Ritenour AE, McLaughlin DF, et al. Injury severity and causes of death from
[Computed tomography of the lungs. A step into the fourth dimension].
Dinkel, J; Hintze, C; Rochet, N; Thieke, C; Biederer, J
2009-08-01
To discuss the techniques for four dimensional computed tomography of the lungs in tumour patients. The image acquisition in CT can be done using respiratory gating in two different ways: the helical or cine mode. In the helical mode, the couch moves continuously during image and respiratory signal acquisition. In the cine mode, the couch remains in the same position during at least one complete respiratory cycle and then moves to next position. The 4D images are either acquired prospectively or reconstructed retrospectively with dedicated algorithms in a freely selectable respiratory phase. The time information required for motion depiction in 4D imaging can be obtained with tolerable motion artefacts. Partial projection and stepladder-artifacts are occurring predominantly close to the diaphragm, where the displacement is most prominent. Due to the long exposure times, radiation exposure is significantly higher compared to a simple breathhold helical acquisition. Therefore, the use of 4D-CT is restricted to only specific indications (i.e. radiotherapy planning). 4D-CT of the lung allows evaluating the respiration-correlated displacement of lungs and tumours in space for radiotherapy planning.
Automatic treatment of flight test images using modern tools: SAAB and Aeritalia joint approach
NASA Astrophysics Data System (ADS)
Kaelldahl, A.; Duranti, P.
The use of onboard cine cameras, as well as that of on ground cinetheodolites, is very popular in flight tests. The high resolution of film and the high frame rate of cinecameras are still not exceeded by video technology. Video technology can successfully enter the flight test scenario once the availability of solid-state optical sensors dramatically reduces the dimensions, and weight of TV cameras, thus allowing to locate them in positions compatible with space or operational limitations (e.g., HUD cameras). A proper combination of cine and video cameras is the typical solution for a complex flight test program. The output of such devices is very helpful in many flight areas. Several sucessful applications of this technology are summarized. Analysis of the large amount of data produced (frames of images) requires a very long time. The analysis is normally carried out manually. In order to improve the situation, in the last few years, several flight test centers have devoted their attention to possible techniques which allow for quicker and more effective image treatment.
Zhang, Fan; Hu, Jing; Kelsey, Chris R; Yoo, David; Yin, Fang-Fang; Cai, Jing
2012-11-01
To evaluate the reproducibility of tumor motion probability distribution function (PDF) in stereotactic body radiation therapy (SBRT) of lung cancer using cine megavoltage (MV) images. Cine MV images of 20 patients acquired during three-dimensional conformal (6-11 beams) SBRT treatments were retrospectively analyzed to extract tumor motion trajectories. For each patient, tumor motion PDFs were generated per fraction (PDF(n)) using three selected "usable" beams. Patients without at least three usable beams were excluded from the study. Fractional PDF reproducibility (R(n)) was calculated as the Dice similarity coefficient between PDF(n) to a "ground-truth" PDF (PDF(g)), which was generated using the selected beams of all fractions. The mean of R(n), labeled as R(m), was calculated for each patient and correlated to the patient's mean tumor motion rang (A(m)). Change of R(m) during the course of SBRT treatments was also evaluated. Intra- and intersubject coefficient of variation (CV) of R(m) and A(m) were determined. Thirteen patients had at least three usable beams and were analyzed. The mean of R(m) was 0.87 (range, 0.84-0.95). The mean of A(m) was 3.18 mm (range, 0.46-7.80 mm). R(m) was found to decrease as A(m) increases following an equation of R(m) = 0.17e(-0.9Am) + 0.84. R(m) also decreased slightly throughout the course of treatments. Intersubject CV of R(m) (0.05) was comparable to intrasubject CV of R(m) (range, 0.02-0.09); intersubject CV of A(m) (0.73) was significantly greater than intrasubject CV of A(m) (range, 0.09-0.24). Tumor motion PDF can be determined using cine MV images acquired during the treatments. The reproducibility of lung tumor motion PDF decreased exponentially as the tumor motion range increased and decreased slightly throughout the course of the treatments. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Mazonakis, Michalis; Grinias, Elias; Pagonidis, Konstantin; Tziritas, George; Damilakis, John
2010-02-01
The purpose of this study was to develop and evaluate a semiautomatic method for left ventricular (LV) segmentation on cine MR images and subsequent estimation of cardiac parameters. The study group comprised cardiac MR examinations of 18 consecutive patients with known or suspected coronary artery disease. The new method allowed the automatic detection of the LV endocardial and epicardial boundaries on each short-axis cine MR image using a Bayesian flooding segmentation algorithm and weighted least-squares B-splines minimization. Manual editing of the automatic contours could be performed for unsatisfactory segmentation results. The end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and LV mass estimated by the new method were compared with the reference values obtained by manually tracing the LV cavity borders. The reproducibility of the new method was determined using data from two independent observers. The mean number of endocardial and epicardial outlines not requiring any manual adjustment was more than 80% and 76% of the total contour number per study, respectively. The mean segmentation time including the required manual corrections was 2.3 ± 0.7 min per patient. LV volumes estimated by the semiautomatic method were significantly lower than those by manual tracing (P < 0.05), whereas no difference was found for EF and LV mass (P > 0.05). LV indices estimated by the two methods were well correlated (r >= 0.80). The mean difference between manual and semiautomatic method for estimating EDV, ESV, EF and LV mass was 6.1 ± 7.2 ml, 3.0 ± 5.2 ml, -0.6 ± 4.3% and -6.2 ± 12.2 g, respectively. The intraobserver and interobserver variability associated with the semiautomatic determination of LV indices was 0.5-1.2% and 0.8-3.9%, respectively. The estimation of LV parameters with the new semiautomatic segmentation method is technically feasible, highly reproducible and time effective.
A novel cardiac MR chamber volume model for mechanical dyssynchrony assessment
NASA Astrophysics Data System (ADS)
Song, Ting; Fung, Maggie; Stainsby, Jeffrey A.; Hood, Maureen N.; Ho, Vincent B.
2009-02-01
A novel cardiac chamber volume model is proposed for the assessment of left ventricular mechanical dyssynchrony. The tool is potentially useful for assessment of regional cardiac function and identification of mechanical dyssynchrony on MRI. Dyssynchrony results typically from a contraction delay between one or more individual left ventricular segments, which in turn leads to inefficient ventricular function and ultimately heart failure. Cardiac resynchronization therapy has emerged as an electrical treatment of choice for heart failure patients with dyssynchrony. Prior MRI techniques have relied on assessments of actual cardiac wall changes either using standard cine MR images or specialized pulse sequences. In this abstract, we detail a semi-automated method that evaluates dyssynchrony based on segmental volumetric analysis of the left ventricular (LV) chamber as illustrated on standard cine MR images. Twelve sectors each were chosen for the basal and mid-ventricular slices and 8 sectors were chosen for apical slices for a total of 32 sectors. For each slice (i.e. basal, mid and apical), a systolic dyssynchrony index (SDI) was measured. SDI, a parameter used for 3D echocardiographic analysis of dyssynchrony, was defined as the corrected standard deviation of the time at which minimal volume is reached in each sector. The SDI measurement of a healthy volunteer was 3.54%. In a patient with acute myocardial infarction, the SDI measurements 10.98%, 16.57% and 1.41% for basal, mid-ventricular and apical LV slices, respectively. Based on published 3D echocardiogram reference threshold values, the patient's SDI corresponds to moderate basal dysfunction, severe mid-ventricular dysfunction, and normal apical LV function, which were confirmed on echocardiography. The LV chamber segmental volume analysis model and SDI is feasible using standard cine MR data and may provide more reliable assessment of patients with dyssynchrony especially if the LV myocardium is thin or if the MR images have spatial resolution insufficient for proper resolution of wall thickness-features problematic for dyssynchrony assessment using existing MR techniques.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castillo, S; Castillo, R; Castillo, E
2014-06-15
Purpose: Artifacts arising from the 4D CT acquisition and post-processing methods add systematic uncertainty to the treatment planning process. We propose an alternate cine 4D CT acquisition and post-processing method to consistently reduce artifacts, and explore patient parameters indicative of image quality. Methods: In an IRB-approved protocol, 18 patients with primary thoracic malignancies received a standard cine 4D CT acquisition followed by an oversampling 4D CT that doubled the number of images acquired. A second cohort of 10 patients received the clinical 4D CT plus 3 oversampling scans for intra-fraction reproducibility. The clinical acquisitions were processed by the standard phasemore » sorting method. The oversampling acquisitions were processed using Dijkstras algorithm to optimize an artifact metric over available image data. Image quality was evaluated with a one-way mixed ANOVA model using a correlation-based artifact metric calculated from the final 4D CT image sets. Spearman correlations and a linear mixed model tested the association between breathing parameters, patient characteristics, and image quality. Results: The oversampling 4D CT scans reduced artifact presence significantly by 27% and 28%, for the first cohort and second cohort respectively. From cohort 2, the inter-replicate deviation for the oversampling method was within approximately 13% of the cross scan average at the 0.05 significance level. Artifact presence for both clinical and oversampling methods was significantly correlated with breathing period (ρ=0.407, p-value<0.032 clinical, ρ=0.296, p-value<0.041 oversampling). Artifact presence in the oversampling method was significantly correlated with amount of data acquired, (ρ=-0.335, p-value<0.02) indicating decreased artifact presence with increased breathing cycles per scan location. Conclusion: The 4D CT oversampling acquisition with optimized sorting reduced artifact presence significantly and reproducibly compared to the phase-sorted clinical acquisition.« less
SU-F-T-636: Comprehensive Approach to Motion Assessment for Liver and Pancreas SBRT Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halvorsen, P; Iftimia, I; Hunter, K
2016-06-15
Purpose: Our past practice for liver and pancreas SBRT consisted of free breathing (FB) with gated treatment delivery using a 30-70% phase window. We have recently adopted an assessment method leading to individualized motion management to minimize target motion. We present our results from 47 patients treated with this new approach. Methods: We perform an initial patient coaching and assessment session in our conventional simulator suite to observe the motion of the implanted fiducials with FB anterior and lateral 20-second cine acquisitions. The physician decides whether to attempt inhale or exhale breath-hold (BH). The patient is coached while observing withmore » cine to ascertain their ability to achieve the desired BH mode for long periods as needed for treatment delivery. If the patient cannot comply, a FB approach is adopted using gating or simple ITV method (for patients without fiducials). After achieving a patient-specific motion management mode, we perform CT-simulation using the Varian RPM system to reproduce the chosen mode and record a reference session for treatment delivery. For pre-treatment imaging, the fiducials are observed under fluoro while coaching the patient. Results: Of 47 SBRT cases analyzed, 32 were liver and 15 were pancreas. The chosen techniques were: 32 exhale BH (12 with abdominal compression), 7 FB gated, 4 inhale BH, and 4 FB ITV. Maximum fiducial motion amplitude was 5 mm for the FB gated patients, and less than 5 mm for all BH patients with most able to achieve a maximum amplitude of 3 mm. Conclusion: This study showed that an individualized motion management approach can reduce the target volume and, therefore, the volume of irradiated healthy tissue from liver or pancreas SBRT. Effective coaching is essential in achieving consistent BH with 3 mm amplitude. The fluoro/cine session is helpful in establishing the right coaching approach for each patient.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rong, Y; Walston, S
Purpose: To evaluate the use of 3D optical surface imaging as a new surrogate for respiratory motion gated deep-inspiration breath-hold (DIBH) technique for left breast cancer patients. Methods: Patients with left-sided breast cancer after lumpectomy or mastectomy were selected as candidates for DIBH technique for their external beam radiation therapy. Treatment plans were created on both free breathing (FB) and DIBH CTs to determine whether DIBH was beneficial in reducing heart doses. The Real-time Position Management (RPM) system was used to acquire patient's breathing trace during DIBH CT acquisition and treatment delivery. The reference 3D surface models from FB andmore » DIBH CTs were generated and transferred to the “AlignRT” system for patient positioning and real-time treatment monitoring. MV Cine images were acquired for each beam as quality assurance for intra-fractional position verification. The chest wall excursions measured on these images were used to define the actual target position during treatment, and to investigate the accuracy and reproducibility of RPM and AlignRT. Results: Reduction in heart dose can be achieved for left-sided breast patients using DIBH. Results showed that RPM has poor correlation with target position, as determined by the MV Cine imaging. This indicates that RPM may not be an adequate surrogate in defining the breath-hold level when used alone. Alternatively, the AlignRT surface imaging demonstrated a better correlation with the actual CW excursion during DIBH. Both the vertical and magnitude real-time deltas (RTDs) reported by AlignRT can be used as the gating parameter, with a recommend threshold of ±3 mm and 5 mm, respectively. Conclusion: 3D optical surface imaging serves as a superior target surrogate for the left breast treatment when compared to RPM. Working together with the realtime MV Cine imaging, they ensure accurate patient setup and dose delivery, while minimizing the imaging dose to patients.« less
NASA Astrophysics Data System (ADS)
van Heijst, Tristan C. F.; Philippens, Mariëlle E. P.; Charaghvandi, Ramona K.; den Hartogh, Mariska D.; Lagendijk, Jan J. W.; Desirée van den Bongard, H. J. G.; van Asselen, Bram
2016-02-01
In early-stage breast-cancer patients, accelerated partial-breast irradiation techniques (APBI) and hypofractionation are increasingly implemented after breast-conserving surgery (BCS). For a safe and effective radiation therapy (RT), the influence of intra-fraction motion during dose delivery becomes more important as associated fraction durations increase and targets become smaller. Current image-guidance techniques are insufficient to characterize local target movement in high temporal and spatial resolution for extended durations. Magnetic resonance imaging (MRI) can provide high soft-tissue contrast, allow fast imaging, and acquire images during longer periods. The goal of this study was to quantify intra-fraction motion using MRI scans from 21 breast-cancer patients, before and after BCS, in supine RT position, on two time scales. High-temporal 2-dimensional (2D) MRI scans (cine-MRI), acquired every 0.3 s during 2 min, and three 3D MRI scans, acquired over 20 min, were performed. The tumor (bed) and whole breast were delineated on 3D scans and delineations were transferred to the cine-MRI series. Consecutive scans were rigidly registered and delineations were transformed accordingly. Motion in sub-second time-scale (derived from cine-MRI) was generally regular and limited to a median of 2 mm. Infrequently, large deviations were observed, induced by deep inspiration, but these were temporary. Movement on multi-minute scale (derived from 3D MRI) varied more, although medians were restricted to 2.2 mm or lower. Large whole-body displacements (up to 14 mm over 19 min) were sparsely observed. The impact of motion on standard RT techniques is likely small. However, in novel hypofractionated APBI techniques, whole-body shifts may affect adequate RT delivery, given the increasing fraction durations and smaller targets. Motion management may thus be required. For this, on-line MRI guidance could be provided by a hybrid MRI/RT modality, such as the University Medical Center Utrecht MRI linear accelerator.
Wang, Jian; Xiang, Bo; Lin, Hung Yu; Liu, Hongyu; Freed, Darren; Arora, Rakesh C.; Tian, Ganghong
2015-01-01
Objectives Because the distribution volume and mechanism of extracellular and intravascular MR contrast media differ considerably, the enhancement pattern of chronic myocardial infarction with extracellular or intravascular media might also be different. This study aims to investigate the differences in MR enhancement patterns of chronic myocardial infarction between extracellular and intravascular contrast media. Materials and Methods Twenty pigs with myocardial infarction underwent cine MRI, first pass perfusion MRI and delayed enhancement MRI with extracellular or intravascular media at four weeks after coronary occlusion. Myocardial blood flow (MBF) was determined with microsphere measurement. The infarction histopathological changes were evaluated by hematoxylin and eosin staining and Masson's trichrome method. Results Cine MRI revealed the reduced wall thickening in chronic infarction compared with normal myocardium. Moreover, significant wall thinning in chronic infarction was observed in cine MRI. Peak first-pass signal intensity didn’t significantly differ between chronic infarction and normal myocardium no matter what kinds of contrast media. At the following delayed enhancement phase, extracellular media-enhanced signal intensity was significantly higher in chronic infarction than in normal myocardium. Conversely, intravascular media-enhanced signal intensity was almost equivalent among chronic infarction and normal myocardium. At four weeks after infarction, MBF in chronic infarction approached to that in normal myocardium. Large thick-walled vessels were detected at peri-infarction zones. The cardiomyocytes were replaced by scar tissue consisting of dilated blood vessels and discrete fibers of collagen. Conclusions Chronic infarction was characterized by the significantly reduced wall thickening and the definite wall thinning. First-pass myocardial perfusion defect was not detected in chronic infarction with two media due to the significantly recovered MBF and well-developed collateral vessels. Infarction remodeling enlarged the extracellular compartment, which was available for extracellular media but not accessible to intravascular media. Extracellular media identified chronic infarction as the hyper-enhancement; nonetheless, intravascular media didn’t provide delayed enhancement. PMID:25816056
Han, Fei; Zhou, Ziwu; Du, Dongsu; Gao, Yu; Rashid, Shams; Cao, Minsong; Shaverdian, Narek; Hegde, John V; Steinberg, Michael; Lee, Percy; Raldow, Ann; Low, Daniel A; Sheng, Ke; Yang, Yingli; Hu, Peng
2018-06-01
To optimize and evaluate the respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK-4D-MRI) method in a 0.35 T MRI-guided radiotherapy (MRgRT) system. The study included seven patients with abdominal tumors treated on the MRgRT system. ROCK-4D-MRI and 2D-CINE, was performed immediately after one of the treatment fractions. Motion quantification based on 4D-MRI was compared with those based on 2D-CINE. The image quality of 4D-MRI was evaluated against 4D-CT. The gross tumor volumes (GTV) were defined based on individual respiratory phases of both 4D-MRI and 4D-CT and compared for their variability over the respiratory cycle. The motion measurements based on 4D-MRI matched well with 2D-CINE, with differences of 1.04 ± 0.52 mm in the superior-inferior and 0.54 ± 0.21 mm in the anterior-posterior directions. The image quality scores of 4D-MRI were significantly higher than 4D-CT, with better tumor contrast (3.29 ± 0.76 vs. 1.86 ± 0.90) and less motion artifacts (3.57 ± 0.53 vs. 2.29 ± 0.95). The GTVs were more consistent in 4D-MRI than in 4D-CT, with significantly smaller GTV variability (9.31 ± 4.58% vs. 34.27 ± 23.33%). Our study demonstrated the clinical feasibility of using the ROCK-4D-MRI to acquire high quality, respiratory motion-resolved 4D-MRI in a low-field MRgRT system. The 4D-MRI image could provide accurate dynamic information for radiotherapy treatment planning. Copyright © 2018 Elsevier B.V. All rights reserved.
Piekarski, Eve; Chitiboi, Teodora; Ramb, Rebecca; Latson, Larry A; Bhatla, Puneet; Feng, Li; Axel, Leon
2018-02-01
Residual respiratory motion degrades image quality in conventional cardiac cine MRI (CCMRI). We evaluated whether a free-breathing (FB) radial imaging CCMRI sequence with compressed sensing reconstruction [extradimensional (e.g. cardiac and respiratory phases) golden-angle radial sparse parallel, or XD-GRASP] could provide better image quality than a conventional Cartesian breath-held (BH) sequence in an unselected population of patients undergoing clinical CCMRI. One hundred one patients who underwent BH and FB imaging in a midventricular short-axis plane at a matching location were included. Visual and quantitative image analysis was performed by two blinded experienced readers, using a five-point qualitative scale to score overall image quality and visual signal-to-noise ratio (SNR) grade, with measures of noise and sharpness. End-diastolic and end-systolic left ventricular areas were also measured and compared for both BH and FB images. Image quality was generally better with the BH cines (overall quality grade for BH vs FB images 4 vs 2.9, p < 0.001; noise 0.06 vs 0.08 p < 0.001; SNR grade 4.1 vs 3, p < 0.001), except for sharpness (p = 0.48). There were no significant differences between BH and FB images regarding end-diastolic or end-systolic areas (p = 0.35 and p = 0.12). Eighteen of the 101 patients had poor BH image quality (grade 1 or 2). In this subgroup, the quality of the FB images was better (p = 0.0032), as was the SNR grade (p = 0.003), but there were no significant differences regarding noise and sharpness (p = 0.45 and p = 0.47). Although FB XD-GRASP CCMRI was visually inferior to conventional BH CCMRI in general, it provided improved image quality in the subgroup of patients with respiratory-motion-induced artifacts on BH images.
Self-gated fetal cardiac MRI with tiny golden angle iGRASP: A feasibility study.
Haris, Kostas; Hedström, Erik; Bidhult, Sebastian; Testud, Frederik; Maglaveras, Nicos; Heiberg, Einar; Hansson, Stefan R; Arheden, Håkan; Aletras, Anthony H
2017-07-01
To develop and assess a technique for self-gated fetal cardiac cine magnetic resonance imaging (MRI) using tiny golden angle radial sampling combined with iGRASP (iterative Golden-angle RAdial Sparse Parallel) for accelerated acquisition based on parallel imaging and compressed sensing. Fetal cardiac data were acquired from five volunteers in gestational week 29-37 at 1.5T using tiny golden angles for eddy currents reduction. The acquired multicoil radial projections were input to a principal component analysis-based compression stage. The cardiac self-gating (CSG) signal for cardiac gating was extracted from the acquired radial projections and the iGRASP reconstruction procedure was applied. In all acquisitions, a total of 4000 radial spokes were acquired within a breath-hold of less than 15 seconds using a balanced steady-state free precession pulse sequence. The images were qualitatively compared by two independent observers (on a scale of 1-4) to a single midventricular cine image from metric optimized gating (MOG) and real-time acquisitions. For iGRASP and MOG images, good overall image quality (2.8 ± 0.4 and 2.6 ± 1.3, respectively, for observer 1; 3.6 ± 0.5 and 3.4 ± 0.9, respectively, for observer 2) and cardiac diagnostic quality (3.8 ± 0.4 and 3.4 ± 0.9, respectively, for observer 1; 3.6 ± 0.5 and 3.6 ± 0.9, respectively, for observer 2) were obtained, with visualized myocardial thickening over the cardiac cycle and well-defined myocardial borders to ventricular lumen and liver/lung tissue. For iGRASP, MOG, and real time, left ventricular lumen diameter (14.1 ± 2.2 mm, 14.2 ± 1.9 mm, 14.7 ± 1.1 mm, respectively) and wall thickness (2.7 ± 0.3 mm, 2.6 ± 0.3 mm, 3.0 ± 0.4, respectively) showed agreement and no statistically significant difference was found (all P > 0.05). Images with iGRASP tended to have higher overall image quality scores compared with MOG and particularly real-time images, albeit not statistically significant in this feasibility study (P > 0.99 and P = 0.12, respectively). Fetal cardiac cine MRI can be performed with iGRASP using tiny golden angles and CSG. Comparison with other fetal cardiac cine MRI methods showed that the proposed method produces high-quality fetal cardiac reconstructions. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:207-217. © 2017 International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y; Yin, F; Ren, L
2014-06-15
Purpose: To develop a quasi-cine CBCT reconstruction technique that uses extremely-small angle (∼3°) projections to generate real-time high-quality lung CBCT images. Method: 4D-CBCT is obtained at the beginning and used as prior images. This study uses extremely-small angle (∼3°) on-board projections acquired at a single respiratory phase to reconstruct the CBCT image at this phase. An adaptive constrained free-form deformation (ACFD) method is developed to deform the prior 4D-CBCT volume at the same phase to reconstruct the new CBCT. Quasi-cine CBCT images are obtained by continuously reconstructing CBCT images at subsequent phases every 3° angle (∼0.5s). Note that the priormore » 4D-CBCT images are dynamically updated using the latest CBCT images. The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the efficacy of ACFD. A lung patient was simulated with a tumor baseline shift of 2mm along superior-inferior (SI) direction after every respiratory cycle for 5 cycles. Limited-angle projections were simulated for each cycle. The 4D-CBCT reconstructed by these projections were compared with the ground-truth generated in XCAT.Volume-percentage-difference (VPD) and center-of-mass-shift (COMS) were calculated between the reconstructed and the ground-truth tumors to evaluate their geometric differences.The ACFD was also compared to a principal-component-analysis based motion-modeling (MM) method. Results: Using orthogonal-view 3° projections, the VPD/COMS values for tumor baseline shifts of 2mm, 4mm, 6mm, 8mm, 10mm were 11.0%/0.3mm, 25.3%/2.7mm, 22.4%/2.9mm, 49.5%/5.4mm, 77.2%/8.1mm for the MM method, and 2.9%/0.7mm, 3.9%/0.8mm, 6.2%/1mm, 7.9%/1.2mm, 10.1%/1.1mm for the ACFD method. Using orthogonal-view 0° projections (1 projection only), the ACFD method yielded VPD/COMS results of 5.0%/0.9mm, 10.5%/1.2mm, 15.1%/1.4mm, 20.9%/1.6mm and 24.8%/1.6mm. Using single-view instead of orthogonal-view projections yielded less accurate results for ACFD. Conclusion: The ACFD method accurately reconstructs snapshot CBCT images using orthogonal-view 3° projections. It has a great potential to provide real-time quasi-cine CBCT images for verification in lung radiation therapy. The research is supported by grant from Varian Medical Systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katsar, C.S.; Hunter, W.B.; Sinisterra, X.H.
The salivary glands of the Glassy-winged sharpshooter (GWSS), Homalodisca vitripennis Germar 1821, (syn. H. coagulata, Hemiptera: Cicadellidae) were collected and used to produce a cDNA library. Examination by BLASTX analyses identified 2 viral sequences, one a 610-base pair fragment and a second 839-base pair fragment, both of which had significant homology to viruses within the genus Phytoreovirus. Resequencing of the fragments confirmed sequence validities. These sequences were used for in silico protein translation and BLASTP analysis confirming the established homology. While the GWSS is the primary vector of Pierce's disease of grapes, this is the first report that GWSS maymore » be a vector of a phytoreoviruses. Phylogenetic and homology comparisons with BLASTX, BLASTP, and PAUP analyses indicated that the viral sequences isolated from GWSS were closely related to the viruses in the Family Reoviridae, Genus Phytoreovirus, specifically Rice Dwarf Phytoreovirus (RDV). RDV is the only plant reovirus that is not limited to the phloem. Phytoreoviruses are transmitted in a propagative manner by cicadellid leafhoppers (Hemiptera: Cicadellidae), which acquire and transmit them during feeding. Phytoreoviruses have been reported from Agallian, Agalliopsis, Nephotettix, and Recilia, genera of leafhoppers, with evidence for transovarial transmission. The GWSS, although considered to feed primarily from the xylem, ingests from other plant tissues, such as the phloem and mesophyll during probing similar to other leafhoppers. The feeding behavior and wide host range of the GWSS provides an overlapping condition for these two organisms, leafhopper and virus. GWSS will feed from grasses as a transitory host, and on herbaceous and woody plants as primary hosts, which may favor the acquisition and transmission of Phytoreovirus by this leafhopper. Monitoring for an increase of Phytoreovirus spread in graminaceous crops that are in proximity to vineyards or tree crop orchards, where GWSS occurs, such as in southern California, will provide a better understanding of the potential role of the GWSS as a disease vector in the spread of phytoreoviruses and other plant pathogens. The sequences have been deposited in NCBI database under the accession numbers (EF058280) for GWSS-V1, WHSg013C11 and (EF058281) for GWSS-V2, WHSg024H02. (author) [Spanish] Dos fragmentos de 610 y 839 pares de bases fueron aislados apartir de una genoteca de expresion derivada de las glandulas salivales del cucarron de las alas cristalinas (GWSS), Homalodisca vitripennis, Germar 1821 (syn. H. coagulata) el cual es vector de la enfermedad de Pierce de las uvas. Los resultados de alineamiento utilizando BLASTX, BLASTP y el analisis filogenetico utilizando PAUP indicaron que los fragmentos de DNA estaban relacionado de manera mas cercana a viruses en la familia Reoviridae, genero Phytoreovirus, y especificamente a los virus del enanismo del arroz (RDV) y al virus del tumor de las grietas (WTV). El cucarron de las alas cristalinas es un saltahoja que se alimenta no solo del xilema sino tambien del floema y del mesofilo. Saltahojas del genero Agallian, son los principales vectores de WTV, el cual infecta el floema de plantas dicotiledoneas tumoraciones en las hojas y en las raices. WTV es transmitido por saltahojas y es el unico reovirus que es capaz de infectar tanto tejidos del xilema como del floema. El comportamiento alimentario del GWSS y su amplio rango de hospederos que incluye pastos y plantas herbaceas y lenosas podria proveer la interaccion entre estos dos organismos facilitando la adquisicion y tranmision de fitoreovirus por el GWSS. Un adecuado monitoreo de el incremento en la expansion de reoviruses en cultivos de gramineas asociados al los vinedos en donde GWSS ocurre en regiones tales como el sur de California, y en general el sur de los Estados Unidos, podria proveer un mejor entendimiento del papel del GWSS como vector de fitoreovirus y otros patogenos de plantas. Las sequencias se depositaron en la base de datos NCBI con los siguientes numeros de identificacion: (EF058280) para GWSS-V1, WHSg013C11 y (EF058281) para GWSSV2, WHSg024H02. (author)« less
Brain Management During Trauma
NASA Astrophysics Data System (ADS)
Shatsky, Stanley A.
1984-01-01
The Neurosurgeon faces a dilemma, that is, how to treat and reconstruct the injured skull and brain with limited knowledge as to how the injury occurred. In an attempt to understand such injuries, our group assembled a series of acceleration sleds to experimentally reproduce these injuries in primates and high frame rate flash x-ray cine system to radiographically study their time course.
ERIC Educational Resources Information Center
SEIBERT, WARREN F.; AND OTHERS
PRELIMINARY ANALYSES WERE UNDERTAKEN TO DETERMINE THE POTENTIAL CONTRIBUTION OF MOTION PICTURE FILMS TO FACTOR ANALYTIC STUDIES OF HUMAN INTELLECT. OF PRIMARY CONCERN WERE THE OPERATIONS OF COGNITION AND MEMORY, FORMING TWO OF THE FIVE OPERATION COLUMNS OF GUILFORD'S "STRUCTURE OF INTELLECT." THE CORE REFERENCE FOR THE STUDY WAS DEFINED…
Imaging of high-velocity very small subjects
NASA Astrophysics Data System (ADS)
Haddleton, Graham P.
1993-01-01
The imaging of high velocity (> 2000 m/s), 7 mm Cuboids impacting on various targets is discussed. The reasons why conventional H.S. Cine techniques, even framing at 40,000 pps, are inadequate to record the detail required are outlined. Four different methods of image capture are illustrated giving a direct comparison between state-of-the-art technologies.
European Congress on Biotechnology (3rd) Held at Munich (Germany, F.R.) on 10-14 September 1984,
1985-02-21
FMDV ). tivity. SCP is important as an additive This virus causes a disease of domestic to improve the nutritive quality of livestock and prevention of... FMDV is of animal feed and is also of economic im- considerable economical importance. Vac- portance. Linde Co. has a long tradi- cines are produced
2011-04-01
McFall, M. (2008). Characteristics of deployed Operation Iraqi Freedom military personnel who seek mental health care. Military Medi- cine , 173 , 155...Analysis of VA Health care Utilization among US Global War on Terrorism (GWOT) Veterans . Washington, DC: Department of Veterans Affairs. Kang, H.K
Emergency Department Patients Support the Use of Combat Medics in Their Clinical Care
2015-07-01
indirect supervision is the growing complexity of modern medi- cine . If this level of supervised and controlled training is required of aviation and...readiness of brigade combat teams fighting the Global War on Terror . J Surg Res. 2007;138:25–31. 4. Mabry RL, Apodaca A, Penrod J, et al. Impact of
Development of a feed-forward controller for a tracking telescope
NASA Astrophysics Data System (ADS)
Allen, John S.; Stufflebeam, Joseph L.; Feller, Dan
2004-07-01
This paper develops a State Space model of a feed-forward control system in the frequency domain, and time domain. The results of the mathematical model are implemented and the responses of the Elevation and Azimuth servo controller in a tracking telescope called a Cine-Sextant developed for the Utah Test and Training Range.
Deployment Related Medical Research Program
2010-12-01
vaccines to prevent Staphylococcus aureus infection; priority will be given to those vac- cines that also include protection against methicillin - resistant ...Maryland Staphylococcus aureus is a leading cause of infections impacting all stages of military deployment from skin and soft tissue infec- tions during...deployment and training to wound infections in casu- alties in theater. Furthermore, newly emerging antibiotic- resistant strains of S. aureus in both
El cine anglofono en la ensenanza de ingles (Anglophone Films in the Teaching of English).
ERIC Educational Resources Information Center
Zoreda, Margaret Lee
The use of English-language films as tools for teaching English as a Second Language (ESL) at the university level is examined. The perspective in this paper is that both strong communicative skills and cross-cultural understanding are crucial components of ESL instruction, thus authentic English-language films (i.e., those made for the…
Filovirus-Like Particles as Vaccines and Discovery Tools
2005-06-01
or MARV strains. Classic methods for vaccine development have been tried, including producing and testing attenuated and inactivated viral...MARV challenge [52]. However, an attenuated virus vac- cine is undesirable for filoviruses due to the danger of reversion to wild-type virulence...correct structural proteins is sufficient for forming VLPs. This is true for both nonenveloped viruses, such as parvovirus , papilloma- virus, rotavirus
2011-01-01
Special emphasis was placed on obtaining information on vac- cines , environmental exposures, and combat-related experiences. Electronic deployment...aPercentages rounded up and may not sum to 100. bDeployed in support of the Global War on Terrorism between September 1, 2001, and August 31, 2007
Cavalcante, Fátima Gonçalves; Lau, Luciana Ferreira; Barbosa, Gabriella Ferrarese; Berlim, Daniela Lima Gomes; Menezes, Natasha Coelho; Braga, Daniela de Carvalho; Amorim, Annibal Coelho de; Amorim, Yuri Cavalcante
2016-10-01
The article analyzes the impact of a documentary on the daily lives of mothers and children with disabilities, exhibited at conferences, festivals, universities and schools in Brazil, Colombia and Japan. Produced by film and health professionals, social scientists and a women's network, the feature film "A special day" was awarded at Assim Vivemos VI International Disability Film Festival (2013-2014). The objective is to analyze the impact of the film and its diffusion among professionals and students from health and education areas. We adopted a methodology of cine debates that were recorded, transcribed and coded. The circuit toured 22 locations with one or more exhibitions for 3.370 people, of which nine presentations were analyzed. Our interpretations were guided by the notions as life account, biographical pact, imaginary and social representation. We analyzed gender issues, family and maternal care; reactions, adaptations and life after the diagnosis of disabilities; discrimination and prejudice; school and inclusion. The study showed that the communicative and expressive power of film becomes a powerful social technology to address gender, maternity and disability as an important and strategic issue for public health in the country.
A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol.
Carnes, Greg; Gaede, Stewart; Yu, Edward; Van Dyk, Jake; Battista, Jerry; Lee, Ting-Yim
2009-04-07
Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy chaining' all couch positions using the selected images until an entire 3D volume was produced. The algorithm produced 16 phase volumes to complete a 4D-CT dataset. Additional 4D-CT datasets were also produced using external marker amplitude and phase angle sorting methods. The image quality of the volumes produced by the different methods was quantified by calculating the mean difference of the sorted overlapping slices from adjacent couch positions. The NCC sorted images showed a significant decrease in the mean difference (p < 0.01) for the five patients.
Quantitative analysis of cardiovascular MR images.
van der Geest, R J; de Roos, A; van der Wall, E E; Reiber, J H
1997-06-01
The diagnosis of cardiovascular disease requires the precise assessment of both morphology and function. Nearly all aspects of cardiovascular function and flow can be quantified nowadays with fast magnetic resonance (MR) imaging techniques. Conventional and breath-hold cine MR imaging allow the precise and highly reproducible assessment of global and regional left ventricular function. During the same examination, velocity encoded cine (VEC) MR imaging provides measurements of blood flow in the heart and great vessels. Quantitative image analysis often still relies on manual tracing of contours in the images. Reliable automated or semi-automated image analysis software would be very helpful to overcome the limitations associated with the manual and tedious processing of the images. Recent progress in MR imaging of the coronary arteries and myocardial perfusion imaging with contrast media, along with the further development of faster imaging sequences, suggest that MR imaging could evolve into a single technique ('one stop shop') for the evaluation of many aspects of heart disease. As a result, it is very likely that the need for automated image segmentation and analysis software algorithms will further increase. In this paper the developments directed towards the automated image analysis and semi-automated contour detection for cardiovascular MR imaging are presented.
Zhou, Hehe; Novotny, John E
2007-01-01
To measure the complex mechanics and Lagrangian finite strain of contracting human skeletal muscle in vivo with cine phase contrast MRI (CPC-MRI) applied to the human supraspinatus muscle of the shoulder. Processing techniques are applied to transform velocities from CPC-MRI images to displacements and planar Lagrangian finite strain. An interpolation method describing the continuity of the velocity field and forward-backward and Fourier transform methods were used to track the displacement of regions of interest during a cyclic abduction motion of a subject's arm. The components of the Lagrangian strain tensor were derived during the motion and principal and maximum in-plane shear strain fields calculated. Derived displacement and strain fields are shown that describe the contraction mechanics of the supraspinatus. Strains vary over time during the cyclic motion and are highly nonuniform throughout the muscle. This method presented overcomes the physical resolution of the MRI scanner, which is crucial for the detection of detailed information within muscles, such as the changes that might occur with partial tears of the supraspinatus. These can then be used as input or validation data for modeling human skeletal muscle.
Vijarnsorn, Chodchanok; Rutledge, Jennifer M; Tham, Edythe B; Coe, James Y; Quinonez, Luis; Patton, David J; Noga, Michelle
2014-02-01
Children with right ventricular outflow tract obstructive (RVOTO) lesions require precise quantification of pulmonary artery (PA) size for proper management of branch PA stenosis. We aimed to determine which cardiovascular magnetic resonance (CMR) sequences and planes correlated best with cardiac catheterization and surgical measurements of branch PA size. Fifty-five children with RVOTO lesions and biventricular circulation underwent CMR prior to; either cardiac catheterization (n = 30) or surgery (n = 25) within a 6 month time frame. CMR sequences included axial black blood, axial, coronal oblique and sagittal oblique cine balanced steady-state free precession (bSSFP), and contrast-enhanced magnetic resonance angiography (MRA) with multiplanar reformatting in axial, coronal oblique, sagittal oblique, and cross-sectional planes. Maximal branch PA and stenosis (if present) diameter were measured. Comparisons of PA size on CMR were made to reference methods: (1) catheterization measurements performed in the anteroposterior plane at maximal expansion, and (2) surgical measurement obtained from a maximal diameter sound which could pass through the lumen. The mean differences (Δ) and intra class correlation (ICC) were used to determine agreement between different modalities. CMR branch PA measurements were compared to the corresponding cardiac catheterization measurements in 30 children (7.6 ± 5.6 years). Reformatted MRA showed better agreement for branch PA measurement (ICC > 0.8) than black blood (ICC 0.4-0.6) and cine sequences (ICC 0.6-0.8). Coronal oblique MRA and maximal cross sectional MRA provided the best correlation of right PA (RPA) size with ICC of 0.9 (Δ -0.1 ± 2.1 mm and Δ 0.5 ± 2.1 mm). Maximal cross sectional MRA and sagittal oblique MRA provided the best correlate of left PA (LPA) size (Δ 0.1 ± 2.4 and Δ -0.7 ± 2.4 mm). For stenoses, the best correlations were from coronal oblique MRA of right pulmonary artery (RPA) (Δ -0.2 ± 0.8 mm, ICC 0.9) and sagittal oblique MRA of left pulmonary artery (LPA) (Δ 0.2 ± 1.1 mm, ICC 0.9). CMR PA measurements were compared to surgical measurements in 25 children (5.4 ± 4.8 years). All MRI sequences demonstrated good agreement (ICC > 0.8) with the best (ICC 0.9) from axial cine bSSFP for both RPA and LPA. Maximal cross sectional and angulated oblique reformatted MRA provide the best correlation to catheterization for measurement of branch PA's and stenosis diameter. This is likely due to similar angiographic methods based on reformatting techniques that transect the central axis of the arteries. Axial cine bSSFP CMR was the best surgically measured correlate of PA branch size due to this being a measure of stretched diameter. Knowledge of these differences provides more precise PA measurements and may aid catheter or surgical interventions for RVOTO lesions.
Temporal analysis of regional wall motion from cine cardiac MRI
NASA Astrophysics Data System (ADS)
Ratib, Osman M.; Didier, Dominique; Chretien, Anne; Rosset, Antoine; Magnin, Isabelle E.; Ligier, Yves
1996-04-01
The purpose of this work is to develop and to evaluate an automatic analysis technique for quantitative assessment of cardiac function from cine MRI and to identify regional alterations in synchronicity based on Fourier analysis of ventricular wall motion (WM). A temporal analysis technique of left ventricular wall displacement was developed for quantitative analysis of temporal delays in wall motion and applied to gated cine 'dark blood' cardiac MRI. This imaging technique allows the user to saturate the blood both above and below the imaging slice simultaneously by using a specially designed rf presaturation pulse. The acquisition parameters are: TR equals 25 - 60 msec, TE equals 5 - 7 msec, 0 equals 25 degrees, slice thickness equals 10 mm, 16 to 32 frames/cycle. Automatic edge detection was used to outline the ventricular cavities on all frames of a cardiac cycle. Two different segmentation techniques were applied to all studies and lead to similar results. Further improvement in edge detection accuracy was achieved by temporal interpolation of individual contours on each image of the cardiac cycle. Radial analysis of the ventricular wall motion was then performed along 64 radii drawn from the center of the ventricular cavity. The first harmonic of the Fourier transform of each radial motion curve is calculated. The phase of the fundamental Fourier component is used as an index of synchrony (delay) of regional wall motion. Results are displayed in color-coded maps of regional alterations in the amplitude and synchrony of wall motion. The temporal delays measured from individual segments are evaluated through a histogram of phase distribution, where the width of the main peak is used as an index of overall synchrony of wall motion. The variability of this technique was validated in 10 normal volunteers and was used to identify regions with asynchronous WM in 15 patients with documented CAD. The standard deviation (SD) of phase distribution measured in short axis views was calculated and used to identify regions with asynchronous wall motion in patients with coronary artery disease. Results suggest that this technique is more sensitive than global functional parameters such as ejection fraction for the detection of ventricular dysfunction. Color coded parametric display offers a more convenient way for the identification and localization of regional wall motion asynchrony. Data obtained from endocardial wall motion analysis were not significantly different from wall thickening measurements. The innovative approach of evaluating the temporal behavior of regional wall motion anomalies is expected to provide clinically relevant data about subtle alteration that cannot be detected through simple analysis of the extent (amplitude) of wall motion or myocardial thickening. Temporal analysis of regional WM abnormality from cine MRI offers an innovative and promising means for objective quantitative evaluation of subtle regional abnormalities. Color coded parametric maps allowed a better identification and localization of regional WM asynchrony.
Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowshanfarzad, Pejman; Sabet, Mahsheed; O'Connor, Daryl J.
2012-02-15
Purpose: Electronic portal imaging devices (EPIDs) have been studied and used for pretreatment and in-vivo dosimetry applications for many years. The application of EPIDs for dosimetry in arc treatments requires accurate characterization of the mechanical sag of the EPID and gantry during rotation. Several studies have investigated the effects of gravity on the sag of these systems but each have limitations. In this study, an easy experiment setup and accurate algorithm have been introduced to characterize and correct for the effect of EPID and gantry sag during arc delivery. Methods: Three metallic ball bearings were used as markers in themore » beam: two of them fixed to the gantry head and the third positioned at the isocenter. EPID images were acquired during a 360 deg. gantry rotation in cine imaging mode. The markers were tracked in EPID images and a robust in-house developed MATLAB code was used to analyse the images and find the EPID sag in three directions as well as the EPID + gantry sag by comparison to the reference gantry zero image. The algorithm results were then tested against independent methods. The method was applied to compare the effect in clockwise and counter clockwise gantry rotations and different source-to-detector distances (SDDs). The results were monitored for one linear accelerator over a course of 15 months and six other linear-accelerators from two treatment centers were also investigated using this method. The generalized shift patterns were derived from the data and used in an image registration algorithm to correct for the effect of the mechanical sag in the system. The Gamma evaluation (3%, 3 mm) technique was used to investigate the improvement in alignment of cine EPID images of a fixed field, by comparing both individual images and the sum of images in a series with the reference gantry zero image. Results: The mechanical sag during gantry rotation was dependent on the gantry angle and was larger in the in-plane direction, although the patterns were not identical for various linear-accelerators. The reproducibility of measurements was within 0.2 mm over a period of 15 months. The direction of gantry rotation and SDD did not affect the results by more than 0.3 mm. Results of independent tests agreed with the algorithm within the accuracy of the measurement tools. When comparing summed images, the percentage of points with Gamma index <1 increased from 85.4% to 94.1% after correcting for the EPID sag, and to 99.3% after correction for gantry + EPID sag. Conclusions: The measurement method and algorithms introduced in this study use cine-images, are highly accurate, simple, fast, and reproducible. It tests all gantry angles and provides a suitable automatic analysis and correction tool to improve EPID dosimetry and perform comprehensive linac QA for arc treatments.« less
2006-08-01
severe aortic stenosis . Figure 1F. Oblique axial cine bright blood imaging through the valve plane of the aorta, demonstrates the aortic valve to...the ascending aorta. This moderate to large jet is consistent with moderate to severe aortic stenosis . No diastolic jet to suggest aortic ...conditions. Functional impairment of the aortic valve—namely aortic stenosis and aortic regurgitation—is the most common complication (in up to 68-85% of
Viral Vaccine Immunogenicity in Relation to Host Cell-Mediated and Humoral Immune Responses.
1976-05-01
adjuvants, particularly complete Freund’s adjuvant or Bordetella pertussis , were donors capable of consistently transferring adoptive immunity...vac- cine combined with adjuvants, particularly complete Freund’s adjuvant or Bordetella pertussis , were donors capable of consistently transferring...Freund’s adjuvant and Bordetella pertussis , are consistently capable of producing early and brisk serum neutralizing antibody responses in adoptively
1987-01-20
sheep pox vac- cines, artificial insemination , soil testing and others. In the meantime, the Soviet scientists introduced the Soviet sunflower into...voltage po- wer transmission line fr- om the Soviet Union to northern regions of the : DRA, the earth satellite ; link station, road-cum-rail...ISRO in making and sup- plying "vital and sensitive" electronic items re- quired by ISRO for remote sensing satellites , augmented satellite
Interpreting hypernymic propositions in an online medical encyclopedia.
Fiszman, Marcelo; Rindflesch, Thomas C; Kilicoglu, Halil
2003-01-01
Interpretation of semantic propositions from bio-medical texts documents would provide valuable support to natural language processing (NLP) applications. We are developing a methodology to interpret a kind of semantic proposition, the hypernymic proposition, in MEDLINE abstracts. In this paper, we expanded the system to identify these structures in a different discourse domain: the Medical Encyclopedia from the National Library of Medi-cine's MEDLINEplus Website.
Westerdahl, Daniel E; Henry, Timothy D
2016-02-15
Implementation of simulation-based medical education (SBME) can improve cardiovascular fellows' angiography skills and knowledge SBME focused on performing coronary angiography shortened procedure times and decreased the use of cine-fluoroscopy The ACGME mandate and SCAI's Simulation Committee recommendations suggest SBME will play an expanding and integral role in the field of cardiovascular medicine. © 2016 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Gratch, Jonathan
2012-01-01
Project-based learning has long been used in the educational realm as it emphasis a student-centered strategy which promotes meaning, enriched learning that enhances inquiry and problem-solving skills in a rich, authentic environment. The relevance and authentic design of projects may further be enhanced by the use of technology in the classroom.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, D; Kishan, A; Santhanam, A
Purpose: To evaluate the effect of inter- and intra-fractional tumor motion on the error in four-dimensional computed tomography (4DCT) maximal intensity projection (MIP)–based lung tumor internal target volumes (ITV), using deformable image registration of real-time 2D-sagital cine-mode MRI acquired during lung SBRT treatments. Methods: Five lung tumor patients underwent free breathing SBRT treatment on the ViewRay, with dose prescribed to PTV (4DCT MIP-based ITV+3–6mm margin). Sagittal slice cine-MR images (3.5×3.5mm pixels) were acquired through the center of the tumor at 4 frames per second throughout the treatments (3–4 fractions of 21–32 minutes duration). Tumor GTVs were contoured on the firstmore » frame of the cine and tracked throughout the treatment using off-line optical-flow based deformable registration implemented on a GPU cluster. Pseudo-4DCT MIP-based ITVs were generated from MIPs of the deformed GTV contours limited to short segments of image data. All possible pseudo-4DCT MIP-based ITV volumes were generated with 1s resolution and compared to the ITV volume of the entire treatment course. Varying pseudo-4DCT durations from 10-50s were analyzed. Results: Tumors were covered in their entirety by PTV in the patients analysed here. However, pseudo-4DCT based ITV volumes were observed that were as small as 29% of the entire treatment-ITV, depending on breathing irregularity and the duration of pseudo-4DCT. With an increase in duration of pseudo-4DCT from 10–50s the minimum volume acquired from 95% of all pseudo-4DCTs increased from 62%–81% of the treatment ITV. Conclusion: A 4DCT MIP-based ITV offers a ‘snap-shot’ of breathing motion for the brief period of time the tumor is imaged on a specific day. Real time MRI over prolonged periods of time and over multiple treatment fractions shows that the accuracy of this snap-shot varies according to inter- and intra-fractional tumor motion. Further work is required to investigate the dosimetric effect of these results.« less
Sudarski, Sonja; Henzler, Thomas; Haubenreisser, Holger; Dösch, Christina; Zenge, Michael O; Schmidt, Michaela; Nadar, Mariappan S; Borggrefe, Martin; Schoenberg, Stefan O; Papavassiliu, Theano
2017-01-01
Purpose To prospectively evaluate the accuracy of left ventricle (LV) analysis with a two-dimensional real-time cine true fast imaging with steady-state precession (trueFISP) magnetic resonance (MR) imaging sequence featuring sparse data sampling with iterative reconstruction (SSIR) performed with and without breath-hold (BH) commands at 3.0 T. Materials and Methods Ten control subjects (mean age, 35 years; range, 25-56 years) and 60 patients scheduled to undergo a routine cardiac examination that included LV analysis (mean age, 58 years; range, 20-86 years) underwent a fully sampled segmented multiple BH cine sequence (standard of reference) and a prototype undersampled SSIR sequence performed during a single BH and during free breathing (non-BH imaging). Quantitative analysis of LV function and mass was performed. Linear regression, Bland-Altman analysis, and paired t testing were performed. Results Similar to the results in control subjects, analysis of the 60 patients showed excellent correlation with the standard of reference for single-BH SSIR (r = 0.93-0.99) and non-BH SSIR (r = 0.92-0.98) for LV ejection fraction (EF), volume, and mass (P < .0001 for all). Irrespective of breath holding, LV end-diastolic mass was overestimated with SSIR (standard of reference: 163.9 g ± 58.9, single-BH SSIR: 178.5 g ± 62.0 [P < .0001], non-BH SSIR: 175.3 g ± 63.7 [P < .0001]); the other parameters were not significantly different (EF: 49.3% ± 11.9 with standard of reference, 48.8% ± 11.8 with single-BH SSIR, 48.8% ± 11 with non-BH SSIR; P = .03 and P = .12, respectively). Bland-Altman analysis showed similar measurement errors for single-BH SSIR and non-BH SSIR when compared with standard of reference measurements for EF, volume, and mass. Conclusion Assessment of LV function with SSIR at 3.0 T is noninferior to the standard of reference irrespective of BH commands. LV mass, however, is overestimated with SSIR. © RSNA, 2016 Online supplemental material is available for this article.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meier, J; Lopez, B; Mawlawi, O
2016-06-15
Purpose: To quantify the impact of 4D PET/CT on PERCIST metrics in lung and liver tumors in NSCLC and colorectal cancer patients. Methods: 32 patients presenting lung or liver tumors of 1–3 cm size affected by respiratory motion were scanned on a GE Discovery 690 PET/CT. The bed position with lesion(s) affected by motion was acquired in a 12 minute PET LIST mode and unlisted into 8 bins with respiratory gating. Three different CT maps were used for attenuation correction: a clinical helical CT (CT-clin), an average CT (CT-ave), and an 8-phase 4D CINE CT (CT-cine). All reconstructions were 3Dmore » OSEM, 2 iterations, 24 subsets, 6.4 Gaussian filtration, 192×192 matrix, non-TOF, and non-PSF. Reconstructions using CT-clin and CT-ave used only 3 out of the 12 minutes of the data (clinical protocol); all 12 minutes were used for the CT-cine reconstruction. The percent change of SUVbw-peak and SUVbw-max was calculated between PET-CTclin and PET-CTave. The same percent change was also calculated between PET-CTclin and PET-CTcine in each of the 8 bins and in the average of all bins. A 30% difference from PET-CTclin classified lesions as progressive metabolic disease (PMD) using maximum bin value and the average of eight bin values. Results: 30 lesions in 25 patients were evaluated. Using the bin with maximum SUVbw-peak and SUVbw-max difference, 4 and 13 lesions were classified as PMD, respectively. Using the average bin values for SUVbw-peak and SUVbw-max, 3 and 6 lesions were classified as PMD, respectively. Using PET-CTave values for SUVbw-peak and SUVbw-max, 4 and 3 lesions were classified as PMD, respectively. Conclusion: These results suggest that response evaluation in 4D PET/CT is dependent on SUV measurement (SUVpeak vs. SUVmax), number of bins (single or average), and the CT map used for attenuation correction.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, J; Jung, J; Yi, B
2015-06-15
Purpose: To test a method to reconstruct a four-dimensional (4D) dose distribution using the correlation of pre-calculated 4D electronic portal imaging device (EPID) images and measured cine-EPID images. Methods: 1. A phantom designed to simulate a tumor in lung (a polystyrene block with 3.0 cm diameter embedded in cork) was placed on a sinusoidally moving platform with 2 cm amplitude and 4 sec/cycle. Ten-phase 4D CT images were acquired for treatment planning and dose reconstruction. A 6MV photon beam was irradiated on the phantom with static (field size=5×8.5 cm{sup 2}) and dynamic fields (sliding windows, 10×10 cm{sup 2}, X1 MLCmore » closing in parallel with the tumor movement). 2. 4D and 3D doses were calculated forwardly on PTV (1 cm margin). 3. Dose images on EPID under the fields were calculated for 10 phases. 4. Cine EPID images were acquired during irradiation. 5. Their acquisition times were correlated to the phases of the phantom at which irradiation occurred by inter-comparing calculated “reference” EPID images with measured images (2D gamma comparison). For the dynamic beam, the tumor was hidden under MLCs during a portion of irradiation time; the correlation performed when the tumor was visible was extrapolated. 6. Dose for each phase was reconstructed on the 4D CT images and summed over all phases. The summation was compared with forwardly calculated 4D and 3D dose distributions. Monte Carlo methods were used for all calculations. Results: For the open and dynamic beams, the 4D reconstructed doses showed the pass rates of 92.7 % and 100 %, respectively, at the isocenter plane given 3% / 3 mm criteria. The better agreement of the dynamic beam was from its dose gradient which blurred the otherwise sharp difference between forward and reconstructed doses. This also contributed slightly better agreement in DVH of PTV. Conclusion: The feasibility of 4D reconstruction was demonstrated.« less
Stress Perfusion Coronary Flow Reserve Versus Cardiac Magnetic Resonance for Known or Suspected CAD.
Kato, Shingo; Saito, Naka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Taguri, Masataka; Kosuge, Masami; Kimura, Kazuo
2017-08-15
Phase-contrast (PC) cine magnetic resonance imaging (MRI) of the coronary sinus is a noninvasive method to quantify coronary flow reserve (CFR). This study sought to compare the prognostic value of CFR by cardiac magnetic resonance (CMR) and stress perfusion CMR to predict major adverse cardiac events (MACE). Participants included 276 patients with known coronary artery disease (CAD) and 400 with suspected CAD. CFR was calculated as myocardial blood flow during adenosine triphosphate infusion divided by myocardial blood flow at rest using PC cine MRI of the coronary sinus. During a median follow-up of 2.3 years, 47 patients (7%) experienced MACE. Impaired CFR (<2.0) and >10% ischemia on stress perfusion CMR were significantly associated with MACE in patients with known CAD (hazard ratio [HR]: 5.17 and HR: 5.10, respectively) and suspected CAD (HR: 14.16 and HR: 6.50, respectively). The area under the curve for predicting MACE was 0.773 for CFR and 0.731 for stress perfusion CMR (p = 0.58) for patients with known CAD, and 0.885 for CFR and 0.776 for stress perfusion CMR (p = 0.059) in the group with suspected CAD. In patients with known CAD, sensitivity, specificity, and positive and negative predictive values to predict MACE were 64%, 91%, 38%, and 97%, respectively, for CFR, and 82%, 59%, 15%, and 97%, respectively, for stress perfusion CMR. In the suspected CAD group, these values were 65%, 99%, 80%, and 97%, respectively, for CFR, and 72%, 83%, 22%, and 98%, respectively, for stress perfusion CMR. The predictive values of CFR and stress perfusion CMR for MACE were comparable in patients with known CAD. In patients with suspected CAD, CFR showed higher HRs and areas under the curve than stress perfusion CMR, suggesting that CFR assessment by PC cine MRI might provide better risk stratification for patients with suspected CAD. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
SU-E-J-112: The Impact of Cine EPID Image Acquisition Frame Rate On Markerless Soft-Tissue Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yip, S; Rottmann, J; Berbeco, R
2014-06-01
Purpose: Although reduction of the cine EPID acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor auto-tracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87Hz on an AS1000 portal imager. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for auto-tracking. The difference between the programmed and auto-tracked positions of a Las Vegas phantommore » moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at eleven field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise were correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the auto-tracking errors increased at frame rates lower than 4.29Hz. Above 4.29Hz, changes in errors were negligible with δ<1.60mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R=0.94) and patient studies (R=0.72). Moderate to poor correlation was found between image noise and tracking error with R -0.58 and -0.19 for both studies, respectively. Conclusion: An image acquisition frame rate of at least 4.29Hz is recommended for cine EPID tracking. Motion blurring in images with frame rates below 4.39Hz can substantially reduce the accuracy of auto-tracking. This work is supported in part by the Varian Medical Systems, Inc.« less
The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yip, Stephen, E-mail: syip@lroc.harvard.edu; Rottmann, Joerg; Berbeco, Ross
2014-06-15
Purpose: Although reduction of the cine electronic portal imaging device (EPID) acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor autotracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87 Hz with an amorphous silicon portal imager (AS1000, Varian Medical Systems, Palo Alto, CA). The maximum frame rate of 12.87 Hz is imposed by the EPID. Low frame rate images were obtained bymore » continuous frame averaging. A previously validated tracking algorithm was employed for autotracking. The difference between the programmed and autotracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at 11 field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise are correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the autotracking errors increased at frame rates lower than 4.29 Hz. Above 4.29 Hz, changes in errors were negligible withδ < 1.60 mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R = 0.94) and patient studies (R = 0.72). Moderate to poor correlation was found between image noise and tracking error with R −0.58 and −0.19 for both studies, respectively. Conclusions: Cine EPID image acquisition at the frame rate of at least 4.29 Hz is recommended. Motion blurring in the images with frame rates below 4.29 Hz can significantly reduce the accuracy of autotracking.« less
Respiratory motion resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK)
Han, Fei; Zhou, Ziwu; Cao, Minsong; Yang, Yingli; Sheng, Ke; Hu, Peng
2017-01-01
Purpose To propose and validate a respiratory motion resolved, self-gated (SG) 4D-MRI technique to assess patient-specific breathing motion of abdominal organs for radiation treatment planning. Methods The proposed 4D-MRI technique was based on the balanced steady-state free-precession (bSSFP) technique and 3D k-space encoding. A novel ROtating Cartesian K-space (ROCK) reordering method was designed that incorporates repeatedly sampled k-space centerline as the SG motion surrogate and allows for retrospective k-space data binning into different respiratory positions based on the amplitude of the surrogate. The multiple respiratory-resolved 3D k-space data were subsequently reconstructed using a joint parallel imaging and compressed sensing method with spatial and temporal regularization. The proposed 4D-MRI technique was validated using a custom-made dynamic motion phantom and was tested in 6 healthy volunteers, in whom quantitative diaphragm and kidney motion measurements based on 4D-MRI images were compared with those based on 2D-CINE images. Results The 5-minute 4D-MRI scan offers high-quality volumetric images in 1.2×1.2×1.6mm3 and 8 respiratory positions, with good soft-tissue contrast. In phantom experiments with triangular motion waveform, the motion amplitude measurements based on 4D-MRI were 11.89% smaller than the ground truth, whereas a −12.5% difference was expected due to data binning effects. In healthy volunteers, the difference between the measurements based on 4D-MRI and the ones based on 2D-CINE were 6.2±4.5% for the diaphragm, 8.2±4.9% and 8.9±5.1% for the right and left kidney. Conclusion The proposed 4D-MRI technique could provide high resolution, high quality, respiratory motion resolved 4D images with good soft-tissue contrast and are free of the “stitching” artifacts usually seen on 4D-CT and 4D-MRI based on resorting 2D-CINE. It could be used to visualize and quantify abdominal organ motion for MRI-based radiation treatment planning. PMID:28133752
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, D; Pollock, S; Keall, P
Purpose: External respiratory surrogates are often used to predict internal lung tumor motion for beam gating but the assumption of correlation between external and internal surrogates is not always verified resulting in amplitude mismatch and time shift. To test the hypothesis that audiovisual (AV) biofeedback improves the correlation between internal and external respiratory motion, in order to improve the accuracy of respiratory-gated treatments for lung cancer radiotherapy. Methods: In nine lung cancer patients, 2D coronal and sagittal cine-MR images were acquired across two MRI sessions (pre- and mid-treatment) with (1) free breathing (FB) and (2) AV biofeedback. External anterior-posterior (AP)more » respiratory motions of (a) chest and (b) abdomen were simultaneously acquired with physiological measurement unit (PMU, 3T Skyra, Siemens Healthcare Erlangen, Germany) and real-time position management (RPM) system (Varian, Palo Alto, USA), respectively. Internal superior-inferior (SI) respiratory motions of (c) lung tumor (i.e. centroid of auto-segmented lung tumor) and (d) diaphragm (i.e. upper liver dome) were measured from individual cine-MR images across 32 dataset. The four respiratory motions were then synchronized with the cine-MR image acquisition time. Correlation coefficients were calculated in the time variation of two nominated respiratory motions: (1) chest-abdomen, (2) abdomen-diaphragm and (3) diaphragm-lung tumor. The three combinations were compared between FB and AV biofeedback. Results: Compared to FB, AV biofeedback improved chest-abdomen correlation by 17% (p=0.005) from 0.75±0.23 to 0.90±0.05 and abdomen-diaphragm correlation by 4% (p=0.058) from 0.91±0.11 to 0.95±0.05. Compared to FB, AV biofeedback improved diaphragm-lung tumor correlation by 12% (p=0.023) from 0.65±0.21 to 0.74±0.16. Conclusions: Our results demonstrated that AV biofeedback significantly improved the correlation of internal and external respiratory motion, thus suggesting the need of AV biofeedback in respiratory-gated treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Fan; Medical Physics Graduate Program, Duke University, Durham, North Carolina; Hu Jing
2012-11-01
Purpose: To evaluate the reproducibility of tumor motion probability distribution function (PDF) in stereotactic body radiation therapy (SBRT) of lung cancer using cine megavoltage (MV) images. Methods and Materials: Cine MV images of 20 patients acquired during three-dimensional conformal (6-11 beams) SBRT treatments were retrospectively analyzed to extract tumor motion trajectories. For each patient, tumor motion PDFs were generated per fraction (PDF{sub n}) using three selected 'usable' beams. Patients without at least three usable beams were excluded from the study. Fractional PDF reproducibility (R{sub n}) was calculated as the Dice similarity coefficient between PDF{sub n} to a 'ground-truth' PDF (PDF{submore » g}), which was generated using the selected beams of all fractions. The mean of R{sub n}, labeled as R{sub m}, was calculated for each patient and correlated to the patient's mean tumor motion rang (A{sub m}). Change of R{sub m} during the course of SBRT treatments was also evaluated. Intra- and intersubject coefficient of variation (CV) of R{sub m} and A{sub m} were determined. Results: Thirteen patients had at least three usable beams and were analyzed. The mean of R{sub m} was 0.87 (range, 0.84-0.95). The mean of A{sub m} was 3.18 mm (range, 0.46-7.80 mm). R{sub m} was found to decrease as A{sub m} increases following an equation of R{sub m} = 0.17e{sup -0.9Am} + 0.84. R{sub m} also decreased slightly throughout the course of treatments. Intersubject CV of R{sub m} (0.05) was comparable to intrasubject CV of R{sub m} (range, 0.02-0.09); intersubject CV of A{sub m} (0.73) was significantly greater than intrasubject CV of A{sub m} (range, 0.09-0.24). Conclusions: Tumor motion PDF can be determined using cine MV images acquired during the treatments. The reproducibility of lung tumor motion PDF decreased exponentially as the tumor motion range increased and decreased slightly throughout the course of the treatments.« less
Respiratory motion-resolved, self-gated 4D-MRI using rotating cartesian k-space (ROCK).
Han, Fei; Zhou, Ziwu; Cao, Minsong; Yang, Yingli; Sheng, Ke; Hu, Peng
2017-04-01
To propose and validate a respiratory motion resolved, self-gated (SG) 4D-MRI technique to assess patient-specific breathing motion of abdominal organs for radiation treatment planning. The proposed 4D-MRI technique was based on the balanced steady-state free-precession (bSSFP) technique and 3D k-space encoding. A novel rotating cartesian k-space (ROCK) reordering method was designed which incorporates repeatedly sampled k-space centerline as the SG motion surrogate and allows for retrospective k-space data binning into different respiratory positions based on the amplitude of the surrogate. The multiple respiratory-resolved 3D k-space data were subsequently reconstructed using a joint parallel imaging and compressed sensing method with spatial and temporal regularization. The proposed 4D-MRI technique was validated using a custom-made dynamic motion phantom and was tested in six healthy volunteers, in whom quantitative diaphragm and kidney motion measurements based on 4D-MRI images were compared with those based on 2D-CINE images. The 5-minute 4D-MRI scan offers high-quality volumetric images in 1.2 × 1.2 × 1.6 mm 3 and eight respiratory positions, with good soft-tissue contrast. In phantom experiments with triangular motion waveform, the motion amplitude measurements based on 4D-MRI were 11.89% smaller than the ground truth, whereas a -12.5% difference was expected due to data binning effects. In healthy volunteers, the difference between the measurements based on 4D-MRI and the ones based on 2D-CINE were 6.2 ± 4.5% for the diaphragm, 8.2 ± 4.9% and 8.9 ± 5.1% for the right and left kidney. The proposed 4D-MRI technique could provide high-resolution, high-quality, respiratory motion-resolved 4D images with good soft-tissue contrast and are free of the "stitching" artifacts usually seen on 4D-CT and 4D-MRI based on resorting 2D-CINE. It could be used to visualize and quantify abdominal organ motion for MRI-based radiation treatment planning. © 2017 American Association of Physicists in Medicine.
An Automatic Portable Telecine Camera.
1978-08-01
five television frames to achieve synchronous operation, that is about 0.2 second. 6.3 Video recorder noise imnunity The synchronisation pulse separator...display is filmed by a modified 16 am cine camera driven by a control unit in which the camera supply voltage is derived from the field synchronisation ...pulses of the video signal. Automatic synchronisation of the camera mechanism is achieved over a wide range of television field frequencies and the
Sutherland, R D; Guynes, W A; Nichols, C T; Martinez, H E
1982-01-01
Excessive cage strut wear allowing ball-poppet embolization caused the sudden death of a 47 year old lady in whom a DeBakey-Surgitool aortic prosthesis had been implanted nine years earlier. Patients with this type of prosthesis should have periodic valvular cine fluoroscopy with image intensification to allow visualization of significant strut wear or fracture, and appropriate prosthetic valve replacement.
Cardiac Metastasis from Invasive Thymoma Via the Superior Vena Cava: Cardiac MRI Findings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dursun, Memduh, E-mail: memduhdursun@yahoo.com; Sarvar, Sadik; Cekrezi, Bledi
2008-07-15
Cardiac tumors are rare, and metastatic deposits are more common than primary cardiac tumors. We present cardiac magnetic resonance imaging (MRI) findings of a 50-year-old woman with invasive thymoma. Cardiac MRI revealed a heterogeneous, lobulated anterior mediastinal mass invading the superior vena cava and extending to the right atrium. In cine images there was no invasion to the right atrial wall.
Thalhammer, Christof; Renz, Wolfgang; Winter, Lukas; Hezel, Fabian; Rieger, Jan; Pfeiffer, Harald; Graessl, Andreas; Seifert, Frank; Hoffmann, Werner; von Knobelsdorff-Brenkenhoff, Florian; Tkachenko, Valeriy; Schulz-Menger, Jeanette; Kellman, Peter; Niendorf, Thoralf
2012-01-01
Purpose To design, evaluate and apply a two-dimensional 16 channel transmit/receive coil array tailored for cardiac MRI at 7.0 Tesla. Material and Methods The cardiac coil array consists of 2 sections each using 8 elements arranged in a 2 × 4 array. RF safety was validated by SAR simulations. Cardiac imaging was performed using 2D CINE FLASH imaging, T2* mapping and fat-water separation imaging. The characteristics of the coil array were analyzed including parallel imaging performance, left ventricular chamber quantification and overall image quality. Results RF characteristics were found to be appropriate for all subjects included in the study. The SAR values derived from the simulations fall well in the limits of legal guidelines. The baseline SNR advantage at 7.0 T was put to use to acquire 2D CINE images of the heart with a very high spatial resolution of (1 × 1 × 4) mm3. The proposed coil array supports 1D acceleration factors of up to R=4 without impairing image quality significantly. Conclusions The 16 channel TX/RX coil has the capability to acquire high contrast and high spatial resolution images of the heart at 7.0 Tesla. PMID:22706727
Steady-state free precession with myocardial tagging: CSPAMM in a single breathhold.
Zwanenburg, Jaco J M; Kuijer, Joost P A; Marcus, J Tim; Heethaar, Robert M
2003-04-01
A method is presented that combines steady-state free precession (SSFP) cine imaging with myocardial tagging. Before the tagging preparation at each ECG-R wave, the steady-state magnetization is stored as longitudinal magnetization by an alpha/2 flip-back pulse. Imaging is continued immediately after tagging preparation, using linearly increasing startup angles (LISA) with a rampup over 10 pulses. Interleaved segmented k-space ordering is used to prevent artifacts from the increasing signal during the LISA rampup. First, this LISA-SSFP method was evaluated regarding ghost artifacts from the steady-state interruption by comparing LISA with an alpha/2 startup method. Next, LISA-SSFP was compared with spoiled gradient echo (SGRE) imaging, regarding tag contrast-to-noise ratio and tag persistence. The measurements were performed in phantoms and in six subjects applying breathhold cine imaging with tagging (temporal resolution 51 ms). The results show that ghost artifacts are negligible for the LISA method. Compared to the SGRE reference, LISA-SSFP was two times faster, with a slightly better tag contrast-to-noise. Additionally, the tags persisted 126 ms longer with LISA-SSFP than with SGRE imaging. The high efficiency of LISA-SSFP enables the acquisition of complementary tagged (CSPAMM) images in a single breathhold. Copyright 2003 Wiley-Liss, Inc.
Albà, Xènia; Figueras I Ventura, Rosa M; Lekadir, Karim; Tobon-Gomez, Catalina; Hoogendoorn, Corné; Frangi, Alejandro F
2014-12-01
Magnetic resonance imaging (MRI), specifically late-enhanced MRI, is the standard clinical imaging protocol to assess cardiac viability. Segmentation of myocardial walls is a prerequisite for this assessment. Automatic and robust multisequence segmentation is required to support processing massive quantities of data. A generic rule-based framework to automatically segment the left ventricle myocardium is presented here. We use intensity information, and include shape and interslice smoothness constraints, providing robustness to subject- and study-specific changes. Our automatic initialization considers the geometrical and appearance properties of the left ventricle, as well as interslice information. The segmentation algorithm uses a decoupled, modified graph cut approach with control points, providing a good balance between flexibility and robustness. The method was evaluated on late-enhanced MRI images from a 20-patient in-house database, and on cine-MRI images from a 15-patient open access database, both using as reference manually delineated contours. Segmentation agreement, measured using the Dice coefficient, was 0.81±0.05 and 0.92±0.04 for late-enhanced MRI and cine-MRI, respectively. The method was also compared favorably to a three-dimensional Active Shape Model approach. The experimental validation with two magnetic resonance sequences demonstrates increased accuracy and versatility. © 2013 Wiley Periodicals, Inc.
Masui, T; Takehara, Y; Igarashi, T; Ichijo, K; Takahashi, M; Kaneko, M; Nozaki, A
1997-07-01
Breath-hold 2D phase-contrast (PC) cine MR angiography with a phased-array coil and 2D time-of-flight (TOF) MR angiography were performed in the renal arteries and their findings were compared. Breath-hold 2D thin slice PC and TOF MR angiography were performed in 10 normal volunteers for renal arteries. A PC technique with k-space segmentation was utilized with the phased-array coil. A PC technique provided visualization of the renal artery more distally than a TOF technique (4.8 +/- 0.5 cm vs. 3.7 +/- 0.8 cm). With cardiac triggering, distal renal arteries were well demonstrated in PC MR angiography. On PC images, up- or downward movements of the mid to distal renal arteries with aortic pulsatility were recognized. The quality of the images was better with the PC than with the TOF technique (3.4 vs. 2.7). The mid to distal portions of the renal arteries translationally move with aortic pulsatility. To consistently visualize and evaluate them on MR angiography, cardiac triggering might be required to reduce the effects of pulsatile motions of the renal artery in the use of a phased-array coil.
Blood-threshold CMR volume analysis of functional univentricular heart.
Secchi, Francesco; Alì, Marco; Petrini, Marcello; Pluchinotta, Francesca Romana; Cozzi, Andrea; Carminati, Mario; Sardanelli, Francesco
2018-05-01
To validate a blood-threshold (BT) segmentation software for cardiac magnetic resonance (CMR) cine images in patients with functional univentricular heart (FUH). We evaluated retrospectively 44 FUH patients aged 25 ± 8 years (mean ± standard deviation). For each patient, the epicardial contour of the single ventricle was manually segmented on cine images by two readers and an automated BT algorithm was independently applied to calculate end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and cardiac mass (CM). Aortic flow analysis (AFA) was performed on through-plane images to obtain forward volumes and used as a benchmark. Reproducibility was tested in a subgroup of 24 randomly selected patients. Wilcoxon, Spearman, and Bland-Altman statistics were used. No significant difference was found between SV (median 57.7 ml; interquartile range 47.9-75.6) and aortic forward flow (57.4 ml; 48.9-80.4) (p = 0.123), with a high correlation (r = 0.789, p < 0.001). Intra-reader reproducibility was 86% for SV segmentation, and 96% for AFA. Inter-reader reproducibility was 85 and 96%, respectively. The BT segmentation provided an accurate and reproducible assessment of heart function in FUH patients.
NASA Astrophysics Data System (ADS)
Ding, Yu; Chung, Yiu-Cho; Raman, Subha V.; Simonetti, Orlando P.
2009-06-01
Real-time dynamic magnetic resonance imaging (MRI) typically sacrifices the signal-to-noise ratio (SNR) to achieve higher spatial and temporal resolution. Spatial and/or temporal filtering (e.g., low-pass filtering or averaging) of dynamic images improves the SNR at the expense of edge sharpness. We describe the application of a temporal filter for dynamic MR image series based on the Karhunen-Loeve transform (KLT) to remove random noise without blurring stationary or moving edges and requiring no training data. In this paper, we present several properties of this filter and their effects on filter performance, and propose an automatic way to find the filter cutoff based on the autocorrelation of the eigenimages. Numerical simulation and in vivo real-time cardiac cine MR image series spanning multiple cardiac cycles acquired using multi-channel sensitivity-encoded MRI, i.e., parallel imaging, are used to validate and demonstrate these properties. We found that in this application, the noise standard deviation was reduced to 42% of the original with no apparent image blurring by using the proposed filter cutoff. Greater noise reduction can be achieved by increasing the length of the image series. This advantage of KLT filtering provides flexibility in the form of another scan parameter to trade for SNR.
Chen, Mounter C Y; Lu, Po-Chien; Chen, James S Y; Hwang, Ned H C
2005-01-01
Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.
Azcona, Juan Diego; Li, Ruijiang; Mok, Edward; Hancock, Steven; Xing, Lei
2013-03-01
Real-time tracking of implanted fiducials in cine megavoltage (MV) imaging during volumetric modulated arc therapy (VMAT) delivery is complicated due to the inherent low contrast of MV images and potential blockage of dynamic leaves configurations. The purpose of this work is to develop a clinically practical autodetection algorithm for motion management during VMAT. The expected field-specific segments and the planned fiducial position from the Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system were projected onto the MV images. The fiducials were enhanced by applying a Laplacian of Gaussian filter in the spatial domain for each image, with a blob-shaped object as the impulse response. The search of implanted fiducials was then performed on a region of interest centered on the projection of the fiducial when it was within an open field including the case when it was close to the field edge or partially occluded by the leaves. A universal template formula was proposed for template matching and normalized cross correlation was employed for its simplicity and computational efficiency. The search region for every image was adaptively updated through a prediction model that employed the 3D position of the fiducial estimated from the localized positions in previous images. This prediction model allowed the actual fiducial position to be tracked dynamically and was used to initialize the search region. The artifacts caused by electronic interference during the acquisition were effectively removed. A score map was computed by combining both morphological information and image intensity. The pixel location with the highest score was selected as the detected fiducial position. The sets of cine MV images taken during treatment were analyzed with in-house developed software written in MATLAB (The Mathworks, Inc., Natick, MA). Five prostate patients were analyzed to assess the algorithm performance by measuring their positioning accuracy during treatment. The algorithm was able to accurately localize the fiducial position on MV images with success rates of more than 90% per case. The percentage of images in which each fiducial was localized in the studied cases varied between 23% and 65%, with at least one fiducial having been localized between 40% and 95% of the images. This depended mainly on the modulation of the plan and fiducial blockage. The prostate movement in the presented cases varied between 0.8 and 3.5 mm (mean values). The maximum displacement detected among all patients was of 5.7 mm. An algorithm for automatic detection of fiducial markers in cine MV images has been developed and tested with five clinical cases. Despite the challenges posed by complex beam aperture shapes, fiducial localization close to the field edge, partial occlusion of fiducials, fast leaf and gantry movement, and inherently low MV image quality, good localization results were achieved in patient images. This work provides a technique for enabling real-time accurate fiducial detection and tumor tracking during VMAT treatments without the use of extra imaging dose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azcona, Juan Diego; Li Ruijiang; Mok, Edward
2013-03-15
Purpose: Real-time tracking of implanted fiducials in cine megavoltage (MV) imaging during volumetric modulated arc therapy (VMAT) delivery is complicated due to the inherent low contrast of MV images and potential blockage of dynamic leaves configurations. The purpose of this work is to develop a clinically practical autodetection algorithm for motion management during VMAT. Methods: The expected field-specific segments and the planned fiducial position from the Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system were projected onto the MV images. The fiducials were enhanced by applying a Laplacian of Gaussian filter in the spatial domain for each image,more » with a blob-shaped object as the impulse response. The search of implanted fiducials was then performed on a region of interest centered on the projection of the fiducial when it was within an open field including the case when it was close to the field edge or partially occluded by the leaves. A universal template formula was proposed for template matching and normalized cross correlation was employed for its simplicity and computational efficiency. The search region for every image was adaptively updated through a prediction model that employed the 3D position of the fiducial estimated from the localized positions in previous images. This prediction model allowed the actual fiducial position to be tracked dynamically and was used to initialize the search region. The artifacts caused by electronic interference during the acquisition were effectively removed. A score map was computed by combining both morphological information and image intensity. The pixel location with the highest score was selected as the detected fiducial position. The sets of cine MV images taken during treatment were analyzed with in-house developed software written in MATLAB (The Mathworks, Inc., Natick, MA). Five prostate patients were analyzed to assess the algorithm performance by measuring their positioning accuracy during treatment. Results: The algorithm was able to accurately localize the fiducial position on MV images with success rates of more than 90% per case. The percentage of images in which each fiducial was localized in the studied cases varied between 23% and 65%, with at least one fiducial having been localized between 40% and 95% of the images. This depended mainly on the modulation of the plan and fiducial blockage. The prostate movement in the presented cases varied between 0.8 and 3.5 mm (mean values). The maximum displacement detected among all patients was of 5.7 mm. Conclusions: An algorithm for automatic detection of fiducial markers in cine MV images has been developed and tested with five clinical cases. Despite the challenges posed by complex beam aperture shapes, fiducial localization close to the field edge, partial occlusion of fiducials, fast leaf and gantry movement, and inherently low MV image quality, good localization results were achieved in patient images. This work provides a technique for enabling real-time accurate fiducial detection and tumor tracking during VMAT treatments without the use of extra imaging dose.« less
Gómez, Luis Alberto; Montoya, Gladis; Rivera, Hernán Mauricio; Hernández, Juan Carlos
2017-04-01
Introducción. El virus del Zika (ZIKV) es un flavivirus con envoltura, transmitido a los seres humanos principalmente por el vector Aedes aegypti. La infección por ZIKV se ha asociado con un gran neurotropismo y con efectos neuropáticos, como el síndrome de Guillain-Barré en el adulto y la microcefalia fetal y posnatal, así como con un síndrome de infección congénita similar al producido por el virus de la rubéola (RV).Objetivo. Comparar las estructuras moleculares de la proteína de envoltura E del virus del Zika (E-ZIKV) y de la E1 del virus de la rubéola (E1-RV), y plantear posibles implicaciones en el neurotropismo y en las alteraciones del sistema nervioso asociadas con el ZIKV.Materiales y métodos. La secuencia de aminoácidos de la proteína E-ZIKV (PDB: 5iZ7) se alineó con la de la glucopreteína E1 del virus de la rubéola (PDB: 4ADG). Los elementos de la estructura secundaria se determinaron usando los programas Vector NTI Advance®, DSSP y POSA, así como herramientas de gestión de datos (AlignX®). Uno de los criterios principales de comparación y alineación fue la asignación de residuos estructuralmente equivalentes, con más de 70 % de identidad.Resultados. La organización estructural de la proteína E-ZIKV (PDB: 5iZ7) fue similar a la de E1-RV (PDB: 4ADG) (70 a 80 % de identidad), y se observó una correspondencia con la estructura definida para las glucoproteínas de fusión de membrana de clase II de los virus con envoltura. E-ZIKV y E1-RV exhibieron elementos estructurales de fusión muy conservados en la región distal del dominio II, asociados con la unión a los receptores celulares de entrada del virus de la rubéola (glucoproteína de mielina del oligodendrocito, Myelin Oligodendrocyte Glycoprotein, MOG), y con los receptores celulares Axl del ZIKV y de otros flavivirus.Conclusión. La comparación de las proteínas E-ZIKV y E1-RV es un paso necesario hacia la definición de otros factores moleculares determinantes del neurotropismo y la patogenia del ZIKV, el cual puede contribuir a generar estrategias de diagnóstico, prevención y tratamiento de las complicaciones neurológicas inducidas por el ZIKV.
An observation of prominence condensation out of a coronal void
NASA Astrophysics Data System (ADS)
Wagner, W. J.; Newkirk, G., Jr.; Schmidt, H. U.
1983-02-01
Photographic averaging of cine-camera data-frames from the 7 March 1970 eclipse provided a record of the inner white light corona with unusually high resolution for low-contrast features. The authors report that a coronal void, similar to high corona structures associated with prominence formation (MacQueen et al., 1983), extended low into the corona. During eclipse totality, a coronal rain prominence condensed from the base of the void.
Ravel, Sophie; Vreysen, Marc J. B.; Domagni, Kouadjo T.; Causse, Sandrine; Solano, Philippe; de Meeûs, Thierry
2011-01-01
Background African animal trypanosomosis is a major obstacle to the development of more efficient and sustainable livestock production systems in West Africa. Riverine tsetse species such as Glossina palpalis gambiensis Vanderplank and Glossina tachinoides Westwood are the major vectors. A wide variety of control tactics is available to manage these vectors, but their removal will in most cases only be sustainable if the control effort is targeting an entire tsetse population within a circumscribed area. Methodology/Principal Findings In the present study, genetic variation at microsatellite DNA loci was used to examine the population structure of G. p. gambiensis and G. tachinoides inhabiting four adjacent river basins in Burkina Faso, i.e. the Mouhoun, the Comoé, the Niger and the Sissili River Basins. Isolation by distance was significant for both species across river basins, and dispersal of G. tachinoides was ∼3 times higher than that of G. p. gambiensis. Thus, the data presented indicate that no strong barriers to gene flow exists between riverine tsetse populations in adjacent river basins, especially so for G. tachinoides. Conclusions/Significance Therefore, potential re-invasion of flies from adjacent river basins will have to be prevented by establishing buffer zones between the Mouhoun and the other river basin(s), in the framework of the PATTEC (Pan African Tsetse and Trypanosomosis Eradication Campaign) eradication project that is presently targeting the northern part of the Mouhoun River Basin. We argue that these genetic analyses should always be part of the baseline data collection before any tsetse control project is initiated. PMID:21738812
Image-driven, model-based 3D abdominal motion estimation for MR-guided radiotherapy
NASA Astrophysics Data System (ADS)
Stemkens, Bjorn; Tijssen, Rob H. N.; de Senneville, Baudouin Denis; Lagendijk, Jan J. W.; van den Berg, Cornelis A. T.
2016-07-01
Respiratory motion introduces substantial uncertainties in abdominal radiotherapy for which traditionally large margins are used. The MR-Linac will open up the opportunity to acquire high resolution MR images just prior to radiation and during treatment. However, volumetric MRI time series are not able to characterize 3D tumor and organ-at-risk motion with sufficient temporal resolution. In this study we propose a method to estimate 3D deformation vector fields (DVFs) with high spatial and temporal resolution based on fast 2D imaging and a subject-specific motion model based on respiratory correlated MRI. In a pre-beam phase, a retrospectively sorted 4D-MRI is acquired, from which the motion is parameterized using a principal component analysis. This motion model is used in combination with fast 2D cine-MR images, which are acquired during radiation, to generate full field-of-view 3D DVFs with a temporal resolution of 476 ms. The geometrical accuracies of the input data (4D-MRI and 2D multi-slice acquisitions) and the fitting procedure were determined using an MR-compatible motion phantom and found to be 1.0-1.5 mm on average. The framework was tested on seven healthy volunteers for both the pancreas and the kidney. The calculated motion was independently validated using one of the 2D slices, with an average error of 1.45 mm. The calculated 3D DVFs can be used retrospectively for treatment simulations, plan evaluations, or to determine the accumulated dose for both the tumor and organs-at-risk on a subject-specific basis in MR-guided radiotherapy.
Image-driven, model-based 3D abdominal motion estimation for MR-guided radiotherapy.
Stemkens, Bjorn; Tijssen, Rob H N; de Senneville, Baudouin Denis; Lagendijk, Jan J W; van den Berg, Cornelis A T
2016-07-21
Respiratory motion introduces substantial uncertainties in abdominal radiotherapy for which traditionally large margins are used. The MR-Linac will open up the opportunity to acquire high resolution MR images just prior to radiation and during treatment. However, volumetric MRI time series are not able to characterize 3D tumor and organ-at-risk motion with sufficient temporal resolution. In this study we propose a method to estimate 3D deformation vector fields (DVFs) with high spatial and temporal resolution based on fast 2D imaging and a subject-specific motion model based on respiratory correlated MRI. In a pre-beam phase, a retrospectively sorted 4D-MRI is acquired, from which the motion is parameterized using a principal component analysis. This motion model is used in combination with fast 2D cine-MR images, which are acquired during radiation, to generate full field-of-view 3D DVFs with a temporal resolution of 476 ms. The geometrical accuracies of the input data (4D-MRI and 2D multi-slice acquisitions) and the fitting procedure were determined using an MR-compatible motion phantom and found to be 1.0-1.5 mm on average. The framework was tested on seven healthy volunteers for both the pancreas and the kidney. The calculated motion was independently validated using one of the 2D slices, with an average error of 1.45 mm. The calculated 3D DVFs can be used retrospectively for treatment simulations, plan evaluations, or to determine the accumulated dose for both the tumor and organs-at-risk on a subject-specific basis in MR-guided radiotherapy.
Prothmann, Marcel; von Knobelsdorff-Brenkenhoff, Florian; Töpper, Agnieszka; Dieringer, Matthias A; Shahid, Etham; Graessl, Andreas; Rieger, Jan; Lysiak, Darius; Thalhammer, C; Huelnhagen, Till; Kellman, Peter; Niendorf, Thoralf; Schulz-Menger, Jeanette
2016-01-01
Cardiovascular Magnetic Resonance (CMR) provides valuable information in patients with hypertrophic cardiomyopathy (HCM) based on myocardial tissue differentiation and the detection of small morphological details. CMR at 7.0T improves spatial resolution versus today's clinical protocols. This capability is as yet untapped in HCM patients. We aimed to examine the feasibility of CMR at 7.0T in HCM patients and to demonstrate its capability for the visualization of subtle morphological details. We screened 131 patients with HCM. 13 patients (9 males, 56 ±31 years) and 13 healthy age- and gender-matched subjects (9 males, 55 ±31years) underwent CMR at 7.0T and 3.0T (Siemens, Erlangen, Germany). For the assessment of cardiac function and morphology, 2D CINE imaging was performed (voxel size at 7.0T: (1.4x1.4x2.5) mm3 and (1.4x1.4x4.0) mm3; at 3.0T: (1.8x1.8x6.0) mm3). Late gadolinium enhancement (LGE) was performed at 3.0T for detection of fibrosis. All scans were successful and evaluable. At 3.0T, quantification of the left ventricle (LV) showed similar results in short axis view vs. the biplane approach (LVEDV, LVESV, LVMASS, LVEF) (p = 0.286; p = 0.534; p = 0.155; p = 0.131). The LV-parameters obtained at 7.0T where in accordance with the 3.0T data (pLVEDV = 0.110; pLVESV = 0.091; pLVMASS = 0.131; pLVEF = 0.182). LGE was detectable in 12/13 (92%) of the HCM patients. High spatial resolution CINE imaging at 7.0T revealed hyperintense regions, identifying myocardial crypts in 7/13 (54%) of the HCM patients. All crypts were located in the LGE-positive regions. The crypts were not detectable at 3.0T using a clinical protocol. CMR at 7.0T is feasible in patients with HCM. High spatial resolution gradient echo 2D CINE imaging at 7.0T allowed the detection of subtle morphological details in regions of extended hypertrophy and LGE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Wensha, E-mail: wensha.yang@cshs.org; Fan, Zhaoyang; Tuli, Richard
2015-12-01
Purpose: To apply a novel self-gating k-space sorted 4-dimensional MRI (SG-KS-4D-MRI) method to overcome limitations due to anisotropic resolution and rebinning artifacts and to monitor pancreatic tumor motion. Methods and Materials: Ten patients were imaged using 4D-CT, cine 2-dimensional MRI (2D-MRI), and the SG-KS-4D-MRI, which is a spoiled gradient recalled echo sequence with 3-dimensional radial-sampling k-space projections and 1-dimensional projection-based self-gating. Tumor volumes were defined on all phases in both 4D-MRI and 4D-CT and then compared. Results: An isotropic resolution of 1.56 mm was achieved in the SG-KS-4D-MRI images, which showed superior soft-tissue contrast to 4D-CT and appeared to be free of stitchingmore » artifacts. The tumor motion trajectory cross-correlations (mean ± SD) between SG-KS-4D-MRI and cine 2D-MRI in superior–inferior, anterior–posterior, and medial–lateral directions were 0.93 ± 0.03, 0.83 ± 0.10, and 0.74 ± 0.18, respectively. The tumor motion trajectories cross-correlations between SG-KS-4D-MRI and 4D-CT in superior–inferior, anterior–posterior, and medial–lateral directions were 0.91 ± 0.06, 0.72 ± 0.16, and 0.44 ± 0.24, respectively. The average standard deviation of gross tumor volume calculated from the 10 breathing phases was 0.81 cm{sup 3} and 1.02 cm{sup 3} for SG-KS-4D-MRI and 4D-CT, respectively (P=.012). Conclusions: A novel SG-KS-4D-MRI acquisition method capable of reconstructing rebinning artifact–free, high-resolution 4D-MRI images was used to quantify pancreas tumor motion. The resultant pancreatic tumor motion trajectories agreed well with 2D-cine-MRI and 4D-CT. The pancreatic tumor volumes shown in the different phases for the SG-KS-4D-MRI were statistically significantly more consistent than those in the 4D-CT.« less
Cai, Xiaoying; Epstein, Frederick H
2018-04-01
This study aimed to develop a self-navigated method for free-breathing spiral cine displacement encoding with stimulated echoes (DENSE), a myocardial strain imaging technique that uses phase-cycling for artifact suppression. The method needed to address 2 consequences of motion for DENSE: striping artifacts from incomplete suppression of the T 1 -relaxation echo and blurring. The method identifies phase-cycled spiral interleaves at matched respiratory phases by minimizing the residual signal due to T 1 relaxation after phase-cycling subtraction. Next, the method reconstructs image-based navigators from matched phase-cycled interleaves that are comprised of the stimulated echo (ste-iNAVs). Ste-iNAVs are used for motion estimation and compensation of k-space data. The method was demonstrated in phantoms and compared to diaphragm-based navigator (dNAV) and conventional iNAV (c-iNAV) methods for the reconstruction of free-breathing volunteer data sets (N = 10). Phantom experiments demonstrated that the proposed method removes striping artifacts and blurring due to motion. Volunteer results showed that respiratory motion measured by ste-iNAVs was better correlated than c-iNAVs to dNAV data (R 2 = 0.82 ± 0.03 vs. 0.70 ± 0.05, P < 0.05). Match-making reconstructions of free-breathing data sets achieved lower residual T 1 -relaxation echo energy (1.04 ± 0.01 vs. 1.18 ± 0.04 for dNAV and 1.18 ± 0.03 for c-iNAV, P < 0.05), higher apparent SNR (11.93 ± 1.05 vs. 10.68 ± 1.06 for dNAV and 10.66 ± 0.99 for c-iNAV, P < 0.05), and better phase quality (0.147 ± 0.012 vs. 0.166 ± 0.017 for dNAV, P = 0.06, and 0.168 ± 0.015 for c-iNAV, P < 0.05) than dNAV and c-iNAV methods. For free-breathing cine DENSE, the proposed method addresses both types of breathing-induced artifacts and provides better quality images than conventional dNAV and iNAV methods. © 2018 International Society for Magnetic Resonance in Medicine.
Analysis of Magnetic Resonance Image Signal Fluctuations Acquired During MR-Guided Radiotherapy.
Breto, Adrian L; Padgett, Kyle R; Ford, John C; Kwon, Deukwoo; Chang, Channing; Fuss, Martin; Stoyanova, Radka; Mellon, Eric A
2018-03-28
Magnetic resonance-guided radiotherapy (MRgRT) is a new and evolving treatment modality that allows unprecedented visualization of the tumor and surrounding anatomy. MRgRT includes daily 3D magnetic resonance imaging (MRI) for setup and rapidly repeated near real-time MRI scans during treatment for target tracking. One of the more exciting potential benefits of MRgRT is the ability to analyze serial MRIs to monitor treatment response or predict outcomes. A typical radiation treatment (RT) over the span of 10-15 minutes on the MRIdian system (ViewRay, Cleveland, OH) yields thousands of "cine" images, each acquired in 250 ms. This unique data allows for a glimpse in image intensity changes during RT delivery. In this report, we analyze cine images from a single fraction RT of a glioblastoma patient on the ViewRay platform in order to characterize the dynamic signal changes occurring during RT therapy. The individual frames in the cines were saved into DICOM format and read into an MIM image analysis platform (MIM Software, Cleveland, OH) as a time series. The three possible states of the three Cobalt-60 radiation sources-OFF, READY, and ON-were also recorded. An in-house Java plugin for MIM was created in order to perform principal component analysis (PCA) on each of the datasets. The analysis resulted in first PC, related to monotonous signal increase over the course of the treatment fraction. We found several distortion patterns in the data that we postulate result from the perturbation of the magnetic field due to the moving metal parts in the platform while treatment was being administered. The largest variations were detected when all Cobalt-60 sources were OFF. During this phase of the treatment, the gantry and multi-leaf collimators (MLCs) are moving. Conversely, when all Cobalt-60 sources were in the ON position, the image signal fluctuations were minimal, relating to very little mechanical motion. At this phase, the gantry, the MLCs, and sources are fixed in their positions. These findings were confirmed in a study with the daily quality assurance (QA) phantom. While the identified variations were not related to physiological processes, our findings confirm the sensitivity of the developed approach to identify very small fluctuations. Relating these variations to the physical changes that occur during treatment shows the methodical ability of the technique to uncover their underlying sources.
NASA Technical Reports Server (NTRS)
Johnson, Howard C. (Editor)
1988-01-01
Recent advances in high-speed optical and electrooptic devices are discussed in reviews and reports. Topics examined include data quantification and related technologies, high-speed photographic applications and instruments, flash and cine radiography, and novel ultrafast methods. Also considered are optical streak technology, high-speed videographic and photographic equipment, and X-ray streak cameras. Extensive diagrams, drawings, graphs, sample images, and tables of numerical data are provided.
Protective Immunity to Pre-Erythrocytic Stage Malaria
2011-01-01
2). The activation of these cells appears to involve Ags expressing both a repet- itive epitope to mediate high B cell receptor cross-linking and T...cell epitopes to induce the activation of follicular T- helper (TFH) cells [33]. Particular attenuated virus vac- cines meet these criteria and can...probably depends on the activation of CS-protein-specific CD4 TFH cells. RTS,S-primed CD4 T cells can also be recalled with CS- protein peptides to produce
16-channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla.
Oezerdem, Celal; Winter, Lukas; Graessl, Andreas; Paul, Katharina; Els, Antje; Weinberger, Oliver; Rieger, Jan; Kuehne, Andre; Dieringer, Matthias; Hezel, Fabian; Voit, Dirk; Frahm, Jens; Niendorf, Thoralf
2016-06-01
To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T). The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2-dipole antenna. Numerical simulations were used for transmission field homogenization and RF safety validation. RF characteristics were examined in a phantom study. The array's suitability for high spatial resolution two-dimensional (2D) CINE imaging and for real time imaging of the heart was examined in a volunteer study. The arrays transmission fields and RF characteristics are suitable for cardiac MRI at 7.0T. The coil performance afforded a spatial resolution as good as (0.8 × 0.8 × 2.5) mm(3) for segmented 2D CINE MRI at 7.0T which is by a factor of 12 superior versus standardized protocols used in clinical practice at 1.5T. The proposed transceiver array supports 1D acceleration factors of up to R = 6 without impairing image quality significantly. The 16-channel bow tie antenna transceiver array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0 Tesla. Magn Reson Med 75:2553-2565, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Ngo, Tuan Anh; Lu, Zhi; Carneiro, Gustavo
2017-01-01
We introduce a new methodology that combines deep learning and level set for the automated segmentation of the left ventricle of the heart from cardiac cine magnetic resonance (MR) data. This combination is relevant for segmentation problems, where the visual object of interest presents large shape and appearance variations, but the annotated training set is small, which is the case for various medical image analysis applications, including the one considered in this paper. In particular, level set methods are based on shape and appearance terms that use small training sets, but present limitations for modelling the visual object variations. Deep learning methods can model such variations using relatively small amounts of annotated training, but they often need to be regularised to produce good generalisation. Therefore, the combination of these methods brings together the advantages of both approaches, producing a methodology that needs small training sets and produces accurate segmentation results. We test our methodology on the MICCAI 2009 left ventricle segmentation challenge database (containing 15 sequences for training, 15 for validation and 15 for testing), where our approach achieves the most accurate results in the semi-automated problem and state-of-the-art results for the fully automated challenge. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.
Stabilized display of coronary x-ray image sequences
NASA Astrophysics Data System (ADS)
Close, Robert A.; Whiting, James S.; Da, Xiaolin; Eigler, Neal L.
2004-05-01
Display stabilization is a technique by which a feature of interest in a cine image sequence is tracked and then shifted to remain approximately stationary on the display device. Prior simulations indicate that display stabilization with high playback rates ( 30 f/s) can significantly improve detectability of low-contrast features in coronary angiograms. Display stabilization may also help to improve the accuracy of intra-coronary device placement. We validated our automated tracking algorithm by comparing the inter-frame difference (jitter) between manual and automated tracking of 150 coronary x-ray image sequences acquired on a digital cardiovascular X-ray imaging system with CsI/a-Si flat panel detector. We find that the median (50%) inter-frame jitter between manual and automatic tracking is 1.41 pixels or less, indicating a jump no further than an adjacent pixel. This small jitter implies that automated tracking and manual tracking should yield similar improvements in the performance of most visual tasks. We hypothesize that cardiologists would perceive a benefit in viewing the stabilized display as an addition to the standard playback of cine recordings. A benefit of display stabilization was identified in 87 of 101 sequences (86%). The most common tasks cited were evaluation of stenosis and determination of stent and balloon positions. We conclude that display stabilization offers perceptible improvements in the performance of visual tasks by cardiologists.
Cine EPID evaluation of two non-commercial techniques for DIBH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, Christopher; Urribarri, Jaime; Cail, Daniel
2014-02-15
Purpose: To evaluate the efficacy of two noncommercial techniques for deep inspiration breathhold (DIBH) treatment of left-sided breast cancer (LSBC) usingcine electronic portal imaging device (EPID) images. Methods: 23 875 EPID images of 65 patients treated for LSBC at two different cancer treatment centers were retrieved. At the Milford Regional Cancer Center, DIBH stability was maintained by visual alignment of inroom lasers and patient skin tattoos (TAT). At the South Shore Hospital, a distance-measuring laser device (RTSSD) was implemented. For both centers,cine EPID images were acquired at least once per week during beam-on. Chest wall position relative to image boundary wasmore » measured and tracked over the course of treatment for every patient and treatment fraction for which data were acquired. Results: Median intrabeam chest motion was 0.31 mm for the TAT method and 0.37 mm for the RTSSD method. The maximum excursions exceeded our treatment protocol threshold of 3 mm in 0.3% of cases (TAT) and 1.2% of cases (RTSSD). The authors did not observe a clinically significant difference between the two datasets. Conclusions: Both noncommercial techniques for monitoring the DIBH location provided DIBH stability within the predetermined treatment protocol parameters (<3 mm). The intreatment imaging offered by the EPID operating incine mode facilitates retrospective analysis and validation of both techniques.« less
IMGT, the international ImMunoGeneTics information system®
Lefranc, Marie-Paule; Giudicelli, Véronique; Kaas, Quentin; Duprat, Elodie; Jabado-Michaloud, Joumana; Scaviner, Dominique; Ginestoux, Chantal; Clément, Oliver; Chaume, Denys; Lefranc, Gérard
2005-01-01
The international ImMunoGeneTics information system® (IMGT) (http://imgt.cines.fr), created in 1989, by the Laboratoire d'ImmunoGénétique Moléculaire LIGM (Université Montpellier II and CNRS) at Montpellier, France, is a high-quality integrated knowledge resource specializing in the immunoglobulins (IGs), T cell receptors (TRs), major histocompatibility complex (MHC) of human and other vertebrates, and related proteins of the immune systems (RPI) that belong to the immunoglobulin superfamily (IgSF) and to the MHC superfamily (MhcSF). IMGT includes several sequence databases (IMGT/LIGM-DB, IMGT/PRIMER-DB, IMGT/PROTEIN-DB and IMGT/MHC-DB), one genome database (IMGT/GENE-DB) and one three-dimensional (3D) structure database (IMGT/3Dstructure-DB), Web resources comprising 8000 HTML pages (IMGT Marie-Paule page), and interactive tools. IMGT data are expertly annotated according to the rules of the IMGT Scientific chart, based on the IMGT-ONTOLOGY concepts. IMGT tools are particularly useful for the analysis of the IG and TR repertoires in normal physiological and pathological situations. IMGT is used in medical research (autoimmune diseases, infectious diseases, AIDS, leukemias, lymphomas, myelomas), veterinary research, biotechnology related to antibody engineering (phage displays, combinatorial libraries, chimeric, humanized and human antibodies), diagnostics (clonalities, detection and follow up of residual diseases) and therapeutical approaches (graft, immunotherapy and vaccinology). IMGT is freely available at http://imgt.cines.fr. PMID:15608269
Semelka, R C; Tomei, E; Wagner, S; Mayo, J; Caputo, G; O'Sullivan, M; Parmley, W W; Chatterjee, K; Wolfe, C; Higgins, C B
1990-06-01
The validity of geometric formulas to derive mass and volumes in the morphologically abnormal left ventricle is problematic. Imaging techniques that are tomographic and therefore inherently three-dimensional should be more reliable and reproducible between studies in such ventricles. Determination of reproducibility between studies is essential to define the limits of an imaging technique for evaluating the response to therapy. Sequential cine magnetic resonance (MR) studies were performed on patients with dilated cardiomyopathy (n = 11) and left ventricular hypertrophy (n = 8) within a short interval in order to assess interstudy reproducibility. Left ventricular mass, volumes, ejection fraction, and end-systolic wall stress were determined by two independent observers. Between studies, left ventricular mass was highly reproducible for hypertrophied and dilated ventricles, with percent variability less than 6%. Ejection fraction and end-diastolic volume showed close reproducibility between studies, with percent variability less than 5% End-systolic volume varied by 4.3% and 4.5% in dilated cardiomyopathy and 8.4% and 7.2% in left ventricular hypertrophy for the two observers. End-systolic wall stress, which is derived from multiple measurements, varied the greatest, with percent variability of 17.2% and 15.7% in dilated cardiomyopathy and 14.8% and 13% in left ventricular hypertrophy, respectively. The results of this study demonstrate that mass, volume, and functional measurements are reproducible in morphologically abnormal ventricles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulson, Eric S.; Bradley, Julie A.; Wang Dian
2011-04-15
Purpose: Intensity-modulated radiation therapy (IMRT) is a promising treatment modality for patients with head and neck cancer (HNC). The dose distributions from IMRT are static and, thus, are unable to account for variations and/or uncertainties in the relationship between the patient (region being treated) and the beam. Organ motion comprises one such source of this uncertainty, introduced by physiological variation in the position, size, and shape of organs during treatment. In the head and neck, the predominant source of this variation arises from deglutition (swallowing). The purpose of this study was to investigate whether cinematographic MRI (cine MRI) could bemore » used to determine asymmetric (nonuniform) internal margin (IM) components of tumor planning target volumes based on the actual deglutition-induced tumor displacement. Methods: Five head and neck cancer patients were set up in treatment position on a 3 T MRI scanner. Two time series of single-slice, sagittal, cine images were acquired using a 2D FLASH sequence. The first time series was a 12.8 min scan designed to capture the frequency and duration of deglutition in the treatment position. The second time series was a short, 15 s scan designed to capture the displacement of deglutition in the treatment position. Deglutition frequency and mean swallow duration were estimated from the long time series acquisition. Swallowing and resting (nonswallowing) events were identified on the short time series acquisition and displacement was estimated based on contours of gross tumor volume (GTV) generated at each time point of a particular event. A simple linear relationship was derived to estimate 1D asymmetric IMs in the presence of resting- and deglutition-induced displacement. Results: Deglutition was nonperiodic, with frequency and duration ranging from 2.89-24.18 mHz and from 3.86 to 6.10 s, respectively. The deglutition frequency and mean duration were found to vary among patients. Deglutition-induced maximal GTV displacements ranged from 0.00 to 28.36 mm with mean and standard deviation of 4.72{+-}3.18, 3.70{+-}2.81, 2.75{+-}5.24, and 10.40{+-}10.76 mm in the A, P, I, and S directions, respectively. Resting-induced maximal GTV displacement ranged from 0.00 to 5.59 mm with mean and standard deviation of 3.01{+-}1.80, 1.25{+-}1.10, 3.23+2.20, and 2.47{+-}1.11 mm in the A, P, I, and S directions, respectively. For both resting and swallowing states, displacement along the S-I direction dominated displacement along the A-P direction. The calculated IMs were dependent on deglutition frequency, ranging from 3.28-4.37 mm for the lowest deglutition frequency patient to 3.76-6.43 mm for the highest deglutition frequency patient. A statistically significant difference was detected between IMs calculated for P and S directions (p=0.0018). Conclusions: Cine MRI is able to capture tumor motion during deglutition. Swallowing events can be demarcated by MR signal intensity changes caused by anatomy containing fully relaxed spins that move medially into the imaging plane during deglutition. Deglutition is nonperiodic and results in dynamic changes in the tumor position. Deglutition-induced displacements are larger and more variable than resting displacements. The nonzero mean maximum resting displacement indicates that some tumor motion occurs even when the patient is not swallowing. Asymmetric IMs, derived from deglutition frequency, duration, and directional displacement, should be employed to account for tumor motion in HNC RT.« less
1992-01-01
HeLra Fever Vaccine Anna L. Kuhne Hemorrhagic Joan A. Spisso Protects against Lethal Junin Virus B.G. Mahlandt United States Army Medical Challenge in...live-attenuated vac- cine against Argentine hemorrhagic fever (AH F), was evaluated om in non-human primates. Twenty rhesus macaques immunized 3 months...nees that had received 3 logl,• PFU Candid No. I or fewer: all Argentine hemorrhagic fever others, including those receiving 127,200 PFU, maintained
2010-01-01
MediCine and Hyg1cne Epidemiology of Spotted Fever Group and Typhus Group Rickettsial Infection in the Amazon Basin of Peru Brett M. Forshey, Allison...approximately 4% of acute febrile episodes detected in Iquitos, a city located in the Amazon region of northeast- ern Peru , could be attributed to SFGR...2010 to 00-00-2010 4. TITLE AND SUBTITLE Epidemiology Of Spotted Fever Group And Typhus Group Rickettsial Infection In The Amazon Basin Of Peru 5a
Methods and new approaches to the calculation of physiological parameters by videodensitometry
NASA Technical Reports Server (NTRS)
Kedem, D.; Londstrom, D. P.; Rhea, T. C., Jr.; Nelson, J. H.; Price, R. R.; Smith, C. W.; Graham, T. P., Jr.; Brill, A. B.; Kedem, D.
1976-01-01
A complex system featuring a video-camera connected to a video disk, cine (medical motion picture) camera and PDP-9 computer with various input/output facilities has been developed. This system enables the performance of quantitative analysis of various functions recorded in clinical studies. Several studies are described, such as heart chamber volume calculations, left ventricle ejection fraction, blood flow through the lungs and also the possibility of obtaining information about blood flow and constrictions in small cross-section vessels
1989-03-01
AND YELLOW MEDiCINE DRAINAGES IN SOUTHWESTERN MINNESOTA. 12 PERSONAL AUTHOR(S) Clark A. Dobbs 13a TYPE OF REPORT 13b TIME COVERED 14 DATE OF REPORT...Between April 15 and June 15, a three person field team conducted the archaeological survey in the Cottonwood, Redwood, and Yellow Medicine subbasins...sites that are exposed on the ground surface. A three- person survey team can examine between 100 and 150 acres per day, dp ending on field conditions and
Yuan, Da; Yang, Xue; Guo, Jun-Chao
2016-05-01
Public excitement over the award of the 2015 Nobel Prize in Physiology or Medicine to the Chinese medical scientist You-you TU for the discovery of a herbal anti-malarial, may mislead the Chinese people into believing that traditional Chinese herbal medi-cine can be used to cure all disease without any ad-verse effects. The aim of this paper is to explain the advantages and disadvantages of herbal traditional Chinese medicine (TCM) objectively.
Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino
2018-01-01
Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Ebben, Matthew R; Milrad, Sara; Dyke, Jonathan P; Phillips, C Douglas; Krieger, Ana C
2016-03-01
It is known that oronasal masks are not as effective at opening the upper airway compared to nasal only continuous positive airway pressure (CPAP) masks in patients with sleep-disordered breathing. However, the physiological mechanism for this difference in efficacy is not known; although, it has been hypothesized to involve the retroglossal and/or retropalatal region of the upper airway. The objective of this study was to investigate differences in retroglossal and retropalatal anterior-posterior space with the use of oronasal vs. nasal CPAP masks using real-time cine magnetic resonance imaging (cMRI). Ten subjects (eight men, two women) with obstructive sleep apnea (OSA) were given cMRI with both nasal and oronasal CPAP masks. Each subject was imaged with each interface at pressures of 5, 10, and 15 cm of H2O, while in the supine position along the sagittal plane. The oronasal mask produced significantly less airway opening in the retropalatal region of the upper airway compared to the nasal mask interface. During exhalation, mask style had a significant effect on anterior-posterior distance p = 0.016. No differences were found in the retroglossal region between mask styles. Our study confirmed previous findings showing differences in treatment efficacy between oronasal and nasal mask styles. We have shown anatomic evidence that the nasal mask is more effective in opening the upper airway compared to the oronasal mask in the retropalatal region.
Ebben, Matthew R.; Milrad, Sara; Dyke, Jonathan P.; Phillips, C. Douglas; Krieger, Ana C.
2016-01-01
Purpose It is known that oronasal masks are not as effective at opening the upper airway compared to nasal only continuous positive airway pressure (CPAP) masks in patients with sleep disordered breathing. However, the physiological mechanism for this difference in efficacy is not known; although, it has been hypothesized to involve the retroglossal and/or retropalatal region of the upper airway. The objective of this study was to investigate differences in retroglossal and retropalatal anterior-posterior space with the use of oronasal vs. nasal CPAP masks using real-time cine Magnetic Resonance Imaging (cMRI). Methods 10-Subjects (8-men, 2-women) with obstructive sleep apnea (OSA) were given cMRI with both nasal and oronasal CPAP masks. Each subject was imaged with each interface at pressures of 5, 10 and 15 cm of H2O, while in the supine position along the sagittal plane. Results The oronasal mask produced significantly less airway opening in the retropalatal region of the upper airway compared to the nasal mask interface. During exhalation, mask style had a significant effect on anterior-posterior distance p=0.016. No differences were found in the retroglossal region between mask styles. Conclusions Our study confirmed previous findings showing differences in treatment efficacy between oronasal and nasal mask styles. We have shown anatomic evidence that the nasal mask is more effective in opening the upper airway compared to the oronasal mask in the retropalatal region. PMID:25924934
Brenner, L D; Caputo, G R; Mostbeck, G; Steiman, D; Dulce, M; Cheitlin, M D; O'Sullivan, M; Higgins, C B
1992-11-01
The purpose of this study was to evaluate the ability of velocity-encoded nuclear magnetic resonance (NMR) imaging to quantify left to right intracardiac shunts in patients with an atrial septal defect. Quantification of intracardiac shunts is clinically important in planning therapy. Velocity-encoded NMR imaging was used to quantify stroke flow in the aorta and in the main pulmonary artery in a group of patients who were known to have an increased pulmonary to systemic flow ratio (Qp/Qs). The velocity-encoded NMR flow data were used to calculate Qp/Qs, and these values were compared with measurements of Qp/Qs obtained with oximetric data derived from cardiac catheterization and from stroke volume measurements of the two ventricles by using volumetric data from biphasic spin echo and cine NMR images obtained at end-diastole and end-systole. Two independent observers measured Qp/Qs by using velocity-encoded NMR imaging in 11 patients and found Qp/Qs ranging from 1.4:1 to 3.9:1. These measurements correlated well with both oximetric data (r = 0.91, SEE = 0.35) and ventricular volumetric data (r = 0.94, SEE = 0.30). Interobserver reproducibility for Qp/Qs by velocity-encoded NMR imaging was good (r = 0.97, SEE = 0.20). Velocity-encoded NMR imaging is an accurate and reproducible method for measuring Qp/Qs in left to right shunts. Because it is completely noninvasive, it can be used to monitor shunt volume over time.
A device for synchronizing biomechanical data with cine film.
Rome, L C
1995-03-01
Biomechanists are faced with two problems in synchronizing continuous physiological data to discrete, frame-based kinematic data from films. First, the accuracy of most synchronization techniques is good only to one frame and hence depends on framing rate. Second, even if perfectly correlated at the beginning of a 'take', the film and physiological data may become progressively desynchronized as the 'take' proceeds. A system is described, which provides synchronization between cine film and continuous physiological data with an accuracy of +/- 0.2 ms, independent of framing rate and the duration of the film 'take'. Shutter pulses from the camera were output to a computer recording system where they were recorded and counted, and to a digital device which counted the pulses and illuminated the count on the bank of LEDs which was filmed with the subject. Synchronization was performed by using the rising edge of the shutter pulse and by comparing the frame number imprinted on the film to the frame number recorded by the computer system. In addition to providing highly accurate synchronization over long film 'takes', this system provides several other advantages. First, having frame numbers imprinted both on the film and computer record greatly facilitates analysis. Second, the LEDs were designed to show the 'take number' while the camera is coming up to speed, thereby avoiding the use of cue cards which disturb the animal. Finally, use of this device results in considerable savings in film.
Kwon, Heejin; Reid, Scott; Kim, Dongeun; Lee, Sangyun; Cho, Jinhan; Oh, Jongyeong
2018-01-04
This study aimed to evaluate image quality and diagnostic performance of a recently developed navigated three-dimensional magnetic resonance cholangiopancreatography (3D-MRCP) with compressed sensing (CS) based on parallel imaging (PI) and conventional 3D-MRCP with PI only in patients with abnormal bile duct dilatation. This institutional review board-approved study included 45 consecutive patients [non-malignant common bile duct lesions (n = 21) and malignant common bile duct lesions (n = 24)] who underwent MRCP of the abdomen to evaluate bile duct dilatation. All patients were imaged at 3T (MR 750, GE Healthcare, Waukesha, WI) including two kinds of 3D-MRCP using 352 × 288 matrices with and without CS based on PI. Two radiologists independently and blindly assessed randomized images. CS acceleration reduced the acquisition time on average 5 min and 6 s to a total of 2 min and 56 s. The all CS cine image quality was significantly higher than standard cine MR image for all quantitative measurements. Diagnostic accuracy for benign and malignant lesions is statistically different between standard and CS 3D-MRCP. Total image quality and diagnostic accuracy at biliary obstruction evaluation demonstrates that CS-accelerated 3D-MRCP sequences can provide superior quality of diagnostic information in 42.5% less time. This has the potential to reduce motion-related artifacts and improve diagnostic efficacy.
A 2D MTF approach to evaluate and guide dynamic imaging developments.
Chao, Tzu-Cheng; Chung, Hsiao-Wen; Hoge, W Scott; Madore, Bruno
2010-02-01
As the number and complexity of partially sampled dynamic imaging methods continue to increase, reliable strategies to evaluate performance may prove most useful. In the present work, an analytical framework to evaluate given reconstruction methods is presented. A perturbation algorithm allows the proposed evaluation scheme to perform robustly without requiring knowledge about the inner workings of the method being evaluated. A main output of the evaluation process consists of a two-dimensional modulation transfer function, an easy-to-interpret visual rendering of a method's ability to capture all combinations of spatial and temporal frequencies. Approaches to evaluate noise properties and artifact content at all spatial and temporal frequencies are also proposed. One fully sampled phantom and three fully sampled cardiac cine datasets were subsampled (R = 4 and 8) and reconstructed with the different methods tested here. A hybrid method, which combines the main advantageous features observed in our assessments, was proposed and tested in a cardiac cine application, with acceleration factors of 3.5 and 6.3 (skip factors of 4 and 8, respectively). This approach combines features from methods such as k-t sensitivity encoding, unaliasing by Fourier encoding the overlaps in the temporal dimension-sensitivity encoding, generalized autocalibrating partially parallel acquisition, sensitivity profiles from an array of coils for encoding and reconstruction in parallel, self, hybrid referencing with unaliasing by Fourier encoding the overlaps in the temporal dimension and generalized autocalibrating partially parallel acquisition, and generalized autocalibrating partially parallel acquisition-enhanced sensitivity maps for sensitivity encoding reconstructions.
Multishot EPI-SSFP in the Heart
Herzka, Daniel A.; Kellman, Peter; Aletras, Anthony H.; Guttman, Michael A.; McVeigh, Elliot R.
2007-01-01
Refocused steady-state free precession (SSFP), or fast imaging with steady precession (FISP or TrueFISP), has recently proven valuable for cardiac imaging because of its high signal-to-noise ratio (SNR) and excellent blood-myocardium contrast. In this study, various implementations of multiecho SSFP or EPI-SSFP for imaging in the heart are presented. EPI-SSFP has higher scan-time efficiency than single-echo SSFP, as two or more phase-encode lines are acquired per repetition time (TR) at the cost of a modest increase in TR. To minimize TR, a noninterleaved phase-encode order in conjunction with a phased-array ghost elimination (PAGE) technique was employed, removing the need for echo time shifting (ETS). The multishot implementation of EPI-SSFP was used to decrease the breath-hold duration for cine acquisitions or to increase the temporal or spatial resolution for a fixed breath-hold duration. The greatest gain in efficiency was obtained with the use of a three-echo acquisition. Image quality for cardiac cine applications using multishot EPI-SSFP was comparable to that of single-echo SSFP in terms of blood-myocardium contrast and contrast-to-noise ratio (CNR). The PAGE method considerably reduced flow artifacts due to both the inherent ghost suppression and the concomitant reduction in phase-encode blip size. The increased TR of multishot EPI-SSFP led to a reduced specific absorption rate (SAR) for a fixed RF flip angle, and allowed the use of a larger flip angle without increasing the SAR above the FDA-approved limits. PMID:11948726
Real-Time Visualization of Joint Cavitation
Rowe, Lindsay
2015-01-01
Cracking sounds emitted from human synovial joints have been attributed historically to the sudden collapse of a cavitation bubble formed as articular surfaces are separated. Unfortunately, bubble collapse as the source of joint cracking is inconsistent with many physical phenomena that define the joint cracking phenomenon. Here we present direct evidence from real-time magnetic resonance imaging that the mechanism of joint cracking is related to cavity formation rather than bubble collapse. In this study, ten metacarpophalangeal joints were studied by inserting the finger of interest into a flexible tube tightened around a length of cable used to provide long-axis traction. Before and after traction, static 3D T1-weighted magnetic resonance images were acquired. During traction, rapid cine magnetic resonance images were obtained from the joint midline at a rate of 3.2 frames per second until the cracking event occurred. As traction forces increased, real-time cine magnetic resonance imaging demonstrated rapid cavity inception at the time of joint separation and sound production after which the resulting cavity remained visible. Our results offer direct experimental evidence that joint cracking is associated with cavity inception rather than collapse of a pre-existing bubble. These observations are consistent with tribonucleation, a known process where opposing surfaces resist separation until a critical point where they then separate rapidly creating sustained gas cavities. Observed previously in vitro, this is the first in-vivo macroscopic demonstration of tribonucleation and as such, provides a new theoretical framework to investigate health outcomes associated with joint cracking. PMID:25875374
New prospective 4D-CT for mitigating the effects of irregular respiratory motion
NASA Astrophysics Data System (ADS)
Pan, Tinsu; Martin, Rachael M.; Luo, Dershan
2017-08-01
Artifact caused by irregular respiration is a major source of error in 4D-CT imaging. We propose a new prospective 4D-CT to mitigate this source of error without new hardware, software or off-line data-processing on the GE CT scanner. We utilize the cine CT scan in the design of the new prospective 4D-CT. The cine CT scan at each position can be stopped by the operator when an irregular respiration occurs, and resumed when the respiration becomes regular. This process can be repeated at one or multiple scan positions. After the scan, a retrospective reconstruction is initiated on the CT console to reconstruct only the images corresponding to the regular respiratory cycles. The end result is a 4D-CT free of irregular respiration. To prove feasibility, we conducted a phantom and six patient studies. The artifacts associated with the irregular respiratory cycles could be removed from both the phantom and patient studies. A new prospective 4D-CT scanning and processing technique to mitigate the impact of irregular respiration in 4D-CT has been demonstrated. This technique can save radiation dose because the repeat scans are only at the scan positions where an irregular respiration occurs. Current practice is to repeat the scans at all positions. There is no cost to apply this technique because it is applicable on the GE CT scanner without new hardware, software or off-line data-processing.
Datta, Anjali; Cheng, Joseph Y; Hargreaves, Brian A; Baron, Corey A; Nishimura, Dwight G
2018-06-01
To mitigate artifacts from through-plane flow at the locations of steady-state stopbands in balanced steady-state free precession (SSFP) using partial dephasing. A 60° range in the phase accrual during a TR was created over the voxel by slightly unbalancing the slice-select dephaser. The spectral profiles of SSFP with partial dephasing for various constant flow rates and during pulsatile flow were simulated to determine if partial dephasing decreases through-plane flow artifacts originating near SSFP dark bands while maintaining on-resonant signal. Simulations were then validated in a flow phantom. Lastly, phase-cycled SSFP cardiac cine images were acquired with and without partial dephasing in six subjects. Partial dephasing decreased the strength and non-linearity of the dependence of the signal at the stopbands on the through-plane flow rate. It thus mitigated hyper-enhancement from out-of-slice signal contributions and transient-related artifacts caused by variable flow both in the phantom and in vivo. In six volunteers, partial dephasing noticeably decreased artifacts in all of the phase-cycled cardiac cine datasets. Partial dephasing can mitigate the flow artifacts seen at the stopbands in balanced SSFP while maintaining the sequence's desired signal. By mitigating hyper-enhancement and transient-related artifacts originating from the stopbands, partial dephasing facilitates robust multiple-acquisition phase-cycled SSFP in the heart. Magn Reson Med 79:2944-2953, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Cusma, Jack T.; Spero, Laurence A.; Groshong, Bennett R.; Cho, Teddy; Bashore, Thomas M.
1993-09-01
An economical and practical digital solution for the replacement of 35 mm cine film as the archive media in the cardiac x-ray imaging environment has remained lacking to date due to the demanding requirements of high capacity, high acquisition rate, high transfer rate, and a need for application in a distributed environment. A clinical digital image library and network based on the D2 digital video format has been installed in the Duke University Cardiac Catheterization Laboratory. The system architecture includes a central image library with digital video recorders and robotic tape retrieval, three acquisition stations, and remote review stations connected via a serial image network. The library has a capacity for over 20,000 Gigabytes of uncompressed image data, equivalent to records for approximately 20,000 patients. Image acquisition in the clinical laboratories is via a real-time digital interface between the digital angiography system and a local digital recorder. Images are transferred to the library over the serial network at a rate of 14.3 Mbytes/sec and permanently stored for later review. The image library and network are currently undergoing a clinical comparison with cine film for visual and quantitative assessment of coronary artery disease. At the conclusion of the evaluation, the configuration will be expanded to include four additional catheterization laboratories and remote review stations throughout the hospital.
Cheng, Christopher P; Parker, David; Taylor, Charles A
2002-09-01
Arterial wall shear stress is hypothesized to be an important factor in the localization of atherosclerosis. Current methods to compute wall shear stress from magnetic resonance imaging (MRI) data do not account for flow profiles characteristic of pulsatile flow in noncircular vessel lumens. We describe a method to quantify wall shear stress in large blood vessels by differentiating velocity interpolation functions defined using cine phase-contrast MRI data on a band of elements in the neighborhood of the vessel wall. Validation was performed with software phantoms and an in vitro flow phantom. At an image resolution corresponding to in vivo imaging data of the human abdominal aorta, time-averaged, spatially averaged wall shear stress for steady and pulsatile flow were determined to be within 16% and 23% of the analytic solution, respectively. These errors were reduced to 5% and 8% with doubling in image resolution. For the pulsatile software phantom, the oscillation in shear stress was predicted to within 5%. The mean absolute error of circumferentially resolved shear stress for the nonaxisymmetric phantom decreased from 28% to 15% with a doubling in image resolution. The irregularly shaped phantom and in vitro investigation demonstrated convergence of the calculated values with increased image resolution. We quantified the shear stress at the supraceliac and infrarenal regions of a human abdominal aorta to be 3.4 and 2.3 dyn/cm2, respectively.
Wang, Haipeng; Qiu, Liyun; Wang, Guangbin; Gao, Fei; Jia, Haipeng; Zhao, Junyu; Chen, Weibo; Wang, Cuiyan; Zhao, Bin
2017-06-01
The cardiac magnetic resonance (CMR) of children at 3.0 T presents a unique set of technical challenges because of their small cardiac anatomical structures, fast heart rates, and the limited ability to keep motionless and hold breathe, which could cause problems associated with field inhomogeneity and degrade the image quality. The aim of our study was to evaluate the effect of dual-source parallel radiofrequency (RF) transmission on the B1 homogeneity and image quality in children with CMR at 3.0 T. The study was approved by the institutional ethics committee and written informed consent was obtained. A total of 30 free-breathing children and 30 breath-hold children performed CMR examinations with dual-source and single-source RF transmission. The B1 homogeneity, contrast ratio (CR) of cine images, and off-resonance artifacts in cine images between dual-source and single-source RF transmission were assessed in free-breathing and breath-hold groups, respectively. In both free-breathing and breath-hold groups, higher mean percentage of flip angle (free-breathing group: 104.2 ± 4.6 vs 95.5 ± 6.3, P < .001; breath-hold group: 101.5 ± 5.1 vs 92.5 ± 6.3, P < .001) and lower coefficient of variation (free-breathing group: 0.06 ± 0.02 vs 0.09 ± 0.03, P < .001; breath-hold group: 0.07 ± 0.03 vs 0.10 ± 0.04, P = .005) were found with dual-source than with single-source RF transmission. Both the CRs in the horizontal long axis (HLA) and short axis of cine images with dual-source RF transmission was improved (P < .05 for all). The scores of off-resonance artifacts in the HLA with dual-source RF transmission were higher in both free-breathing and breath-hold groups (P < .05 for all), with substantial interreader agreement (kappa values from 0.68 to 0.74). Compared with conventional single-source, dual-source parallel RF transmission could significantly improve the B1 homogeneity and image quality for CMR in children at 3.0 T. This technology could be taken into account in CMR for children with cardiac diseases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ubeda, Carlos, E-mail: cubeda@uta.cl; Miranda, Patricia; Vano, Eliseo
Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-areamore » product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm{sup 2} for <1 yr; 1.74 and 1.90 Gy cm{sup 2} for 1 to <5 yr; 2.83 and 3.22 Gy cm{sup 2} for 5 to <10 yr; and 7.34 and 8.68 Gy cm{sup 2} for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm{sup 2}/kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate.« less
Ubeda, Carlos; Miranda, Patricia; Vano, Eliseo
2015-02-01
To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm 2 for <1 yr; 1.74 and 1.90 Gy cm 2 for 1 to <5 yr; 2.83 and 3.22 Gy cm 2 for 5 to <10 yr; and 7.34 and 8.68 Gy cm 2 for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm 2 /kg) for diagnostic and therapeutic procedures. The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate. © 2015 American Association of Physicists in Medicine.
D'Errico, Luigia; Lamacie, Mariana M; Jimenez Juan, Laura; Deva, Djeven; Wald, Rachel M; Ley, Sebastian; Hanneman, Kate; Thavendiranathan, Paaladinesh; Wintersperger, Bernd J
2016-09-22
Test-retest reproducibility is of utmost importance in follow-up of right ventricular (RV) volumes and function; optimal slice orientation though is not yet known. We compared test-retest reproducibility and intra-/inter-observer variability of right ventricular (RV) volumes and function assessed with short-axis and transverse cardiovascular magnetic resonance (CMR). Eighteen volunteers underwent cine CMR for RV assessment obtaining ventricular coverage in short-axis and transverse slice orientation. Additional 2D phase contrast flow imaging of the main pulmonary artery (MPA) was performed. After complete repositioning repeat acquisitions were performed. Data sets were contoured by two blinded observers. Statistical analysis included Student's t-test, Bland-Altman plots, intra-class correlation coefficient (ICC) and 2-way ANOVA, SEM and minimal detectable difference calculations. Heart rates (65.0 ± 7.4 vs. 67.6 ± 9.9 bpm; P = 0.1) and MPA flow (89.8 ± 16.6 vs. 87.2 ± 14.9 mL; P = 0.1) did not differ between imaging sessions. EDV and ESV demonstrated an inter-study bias of 0.4 %[-9.5 %,10.3 %] and 2.1 %[-12.3 %,16.4 %] for short-axis and 1.1 %[-7.3 %,9.4 %] and 0.8 %[-16.0 %,17.6 %] for transverse orientation, respectively. There was no significant interaction between imaging orientation and interstudy reproducibility (p = 0.395-0.824), intra-observer variability (p = 0.726-0.862) or inter-observer variability (p = 0.447-0.706) by 2-way ANOVA. Inter-observer agreement by ICC was greater for short axis versus transverse orientation for all parameters (0.769-0.986 vs. 0.625-0.983, respectively). Minimal detectable differences for short axis and transverse orientations were 10.1 mL/11.5 mL for EDV, 8.3 mL/8.4 mL for ESV and 4.1 % vs. 4.7 % for EF, respectively. Short-axis and transverse orientation both provide reliable and reproducible measures for follow-up of RV volumes and global function. Therefore, additional transverse SSFP cine CMR may not necessarily be required if performed for the sole purpose of quantitative volumetric RV assessment.
Mangion, Kenneth; Clerfond, Guillaume; McComb, Christie; Carrick, David; Rauhalammi, Samuli M; McClure, John; Corcoran, David S; Woodward, Rosemary; Orchard, Vanessa; Radjenovic, Aleksandra; Zhong, Xiaodong; Berry, Colin
2016-11-01
To assess myocardial strain using cine displacement encoding with stimulated echoes (DENSE) using 1.5T and 3.0T MRI in healthy adults. Healthy adults without any history of cardiovascular disease underwent magnetic resonance imaging (MRI) at 1.5T and 3.0T within 2 days. The MRI protocol included balanced steady-state free-precession (b-SSFP), 2D cine-echo planar imaging (EPI)-DENSE, and late gadolinium enhancement in subjects >45 years. Acquisitions were divided into six segments; global and segmental peak longitudinal and circumferential strain were derived and analyzed by field strength, age, and gender. In all, 89 volunteers (mean age 44.8 ± 18.0 years, range: 18-87 years) underwent MRI at 1.5T, and 88 of these subjects underwent MRI at 3.0T (1.4 ± 1.4 days between the scans). Compared with 3.0T, the magnitudes of global circumferential (-19.5 ± 2.6% vs. -18.47 ± 2.6%; P = 0.001) and longitudinal (-12.47 ± 3.2% vs. -10.53 ± 3.1%; P = 0.004) strain were greater at 1.5T. At 1.5T, longitudinal strain was greater in females than in males: -10.17 ± 3.4% vs. -13.67 ± 2.4%; P = 0.001. Similar observations occurred for circumferential strain at 1.5T (-18.72 ± 2.2% vs. -20.10 ± 2.7%; P = 0.014) and at 3.0T (-17.92 ± 1.8% vs. -19.1 ± 3.1%; P = 0.047). At 1.5T, longitudinal and circumferential strain were not associated with age after accounting for sex (longitudinal strain P = 0.178, circumferential strain P = 0.733). At 3.0T, longitudinal and circumferential strain were associated with age (P < 0.05). Longitudinal strain values were greater in the apico-septal, basal-lateral, and mid-lateral segments and circumferential strain in the inferior, infero-lateral, and antero-lateral LV segments. Myocardial strain parameters as revealed by cine-DENSE at different MRI field strengths were associated with myocardial region, age, and sex. J. Magn. Reson. Imaging 2016;44:1197-1205. © 2016 The Authors Journal of Magnetic Resonance Imaging published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Zhu, Yanchun; Spincemaille, Pascal; Liu, Jing; Li, Shuo; Nguyen, Thanh D.; Prince, Martin R.; Xie, Yaoqin; Wang, Yi
2017-01-01
Not Available Project supported by the National Natural Science Foundation of China (Grant Nos. 81501463, 61671026, 81571669, and 81671853), the Natural Science Foundation of Guangdong Province, China (Grant No. 2014A030310360), Guangdong Innovative Research Team Program of China (Grant No. 2011S013), the Basic Research Project of Shenzhen City, China (Grant Nos. JCYJ20140417113430639 and JCYJ20160429172357751), the High-level Oversea Talent Program of Shenzhen City, China (Grant No. KQJSCX20160301144248), and Beijing Center for Mathematics and Information Interdisciplinary Sciences of China.
Analysis of 2D Phase Contrast MRI in Renal Arteries by Self Organizing Maps
NASA Astrophysics Data System (ADS)
Zöllner, Frank G.; Schad, Lothar R.
We present an approach based on self organizing maps to segment renal arteries from 2D PC Cine MR, images to measure blood velocity and flow. Such information are important in grading renal artery stenosis and support the decision on surgical interventions like percu-tan transluminal angioplasty. Results show that the renal arteries could be extracted automatically. The corresponding velocity profiles show high correlation (r=0.99) compared those from manual delineated vessels. Furthermore, the method could detect possible blood flow patterns within the vessel.
Flow Quantification from 2D Phase Contrast MRI in Renal Arteries Using Clustering
NASA Astrophysics Data System (ADS)
Zöllner, Frank G.; Monnsen, Jan Ankar; Lundervold, Arvid; Rørvik, Jarle
We present an approach based on clustering to segment renal arteries from 2D PC Cine MR images to measure blood velocity and flow. Such information are important in grading renal artery stenosis and support the decision on surgical interventions like percutan transluminal angioplasty. Results show that the renal arteries could be extracted automatically and the corresponding velocity profiles could be calculated. Furthermore, the clustering could detect possible phase wrap effects automatically as well as differences in the blood flow patterns within the vessel.
Television animation store: Recording pictures on a parallel transfer magnetic disc
NASA Astrophysics Data System (ADS)
Durey, A. J.
1984-12-01
The recording and replaying of digital video signals using a computer-type magnetic disc-drive as part of an electronic rostrum camera animation system is described. The system was developed to enable picture sequences to be generated directly as television signals, instead of using cine film. The characteristics of the disc-drive are described together with data processing, error protection and signal synchronization systems, which enable digital television YUV component signals, sampled at 12 MHz, 4 MHz and 4 MHz respectively, to be recorded and replayed in real time.
Dynamic, diagnostic, and pharmacological radionuclide studies of the esophagus in achalasia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rozen, P.; Gelfond, M.; Zaltzman, S.
1982-08-01
The esophagus was evaluated in 15 patients with achalasia by continuous gamma camera imaging following ingestion of a semi-solid meal labeled with /sup 99m/Tc. The images were displayed and recorded on a simple computerized data processing/display system. Subsequent cine mode images of esophageal emptying demonstrated abnormalities of the body of the esophagus not reflected by the manometric examination. Computer-generated time-activity curves representing specific regions of interest were better than manometry in evaluating the results of myotomy, dilatation, and drug therapy. Isosorbide dinitrate significantly improved esophageal emptying.
NASA Astrophysics Data System (ADS)
Wormanns, Dag; Fiebich, Martin; Wietholt, Christian; Diederich, Stefan; Heindel, Walter
2000-06-01
We evaluated the practical application of a Computer-Aided Diagnosis (CAD) system for viewing spiral computed tomography (CT) of the chest low-dose screening examinations which includes an automatic detection of pulmonary nodules. A UNIX- based CAD system was developed including a detection algorithm for pulmonary nodules and a user interface providing an original axial image, the same image with nodules highlighted, a thin-slab MIP, and a cine mode. As yet, 26 CT examinations with 1625 images were reviewed in a clinical setting and reported by an experienced radiologist using both the CAD system and hardcopies. The CT studies exhibited 19 nodules found on the hardcopies in consensus reporting of 2 experienced radiologists. Viewing with the CAD system was more time consuming than using hardcopies (4.16 vs. 2.92 min) due to analyzing MIP and cine mode. The algorithm detected 49% (18/37) pulmonary nodules larger than 5 mm and 30% (21/70) of all nodules. It produced an average of 6.3 false positive findings per CT study. Most of the missed nodules were adjacent to the pleura. However, the program detected 6 nodules missed by the radiologists. Automatic nodule detection increases the radiologists's awareness of pulmonary lesions. Simultaneous display of axial image and thin-slab MIP makes the radiologist more confident in diagnosis of smaller pulmonary nodules. The CAD system improves the detection of pulmonary nodules at spiral CT. Lack of sensitivity and specificity is still an issue to be addressed but does not prevent practical use.
Fenner, John; Wright, Benjamin; Emberey, Jonathan; Spencer, Paul; Gillott, Richard; Summers, Angela; Hutchinson, Charles; Lawford, Pat; Brenchley, Paul; Bardhan, Karna Dev
2014-06-01
This paper reports novel development and preliminary application of an image registration technique for diagnosis of abdominal adhesions imaged with cine-MRI (cMRI). Adhesions can severely compromise the movement and physiological function of the abdominal contents, and their presence is difficult to detect. The image registration approach presented here is designed to expose anomalies in movement of the abdominal organs, providing a movement signature that is indicative of underlying structural abnormalities. Validation of the technique was performed using structurally based in vitro and in silico models, supported with Receiver Operating Characteristic (ROC) methods. For the more challenging cases presented to the small cohort of 4 observers, the AUC (area under curve) improved from a mean value of 0.67 ± 0.02 (without image registration assistance) to a value of 0.87 ± 0.02 when image registration support was included. Also, in these cases, a reduction in time to diagnosis was observed, decreasing by between 20% and 50%. These results provided sufficient confidence to apply the image registration diagnostic protocol to sample magnetic resonance imaging data from healthy volunteers as well as a patient suffering from encapsulating peritoneal sclerosis (an extreme form of adhesions) where immobilization of the gut by cocooning of the small bowel is observed. The results as a whole support the hypothesis that movement analysis using image registration offers a possible method for detecting underlying structural anomalies and encourages further investigation. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Montalba, Cristian; Urbina, Jesus; Sotelo, Julio; Andia, Marcelo E; Tejos, Cristian; Irarrazaval, Pablo; Hurtado, Daniel E; Valverde, Israel; Uribe, Sergio
2018-04-01
To assess the variability of peak flow, mean velocity, stroke volume, and wall shear stress measurements derived from 3D cine phase contrast (4D flow) sequences under different conditions of spatial and temporal resolutions. We performed controlled experiments using a thoracic aortic phantom. The phantom was connected to a pulsatile flow pump, which simulated nine physiological conditions. For each condition, 4D flow data were acquired with different spatial and temporal resolutions. The 2D cine phase contrast and 4D flow data with the highest available spatio-temporal resolution were considered as a reference for comparison purposes. When comparing 4D flow acquisitions (spatial and temporal resolution of 2.0 × 2.0 × 2.0 mm 3 and 40 ms, respectively) with 2D phase-contrast flow acquisitions, the underestimation of peak flow, mean velocity, and stroke volume were 10.5, 10 and 5%, respectively. However, the calculated wall shear stress showed an underestimation larger than 70% for the former acquisition, with respect to 4D flow, with spatial and temporal resolution of 1.0 × 1.0 × 1.0 mm 3 and 20 ms, respectively. Peak flow, mean velocity, and stroke volume from 4D flow data are more sensitive to changes of temporal than spatial resolution, as opposed to wall shear stress, which is more sensitive to changes in spatial resolution. Magn Reson Med 79:1882-1892, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Paganelli, Chiara; Lee, Danny; Greer, Peter B.; Baroni, Guido; Riboldi, Marco; Keall, Paul
2015-09-01
The quantification of tumor motion in sites affected by respiratory motion is of primary importance to improve treatment accuracy. To account for motion, different studies analyzed the translational component only, without focusing on the rotational component, which was quantified in a few studies on the prostate with implanted markers. The aim of our study was to propose a tool able to quantify lung tumor rotation without the use of internal markers, thus providing accurate motion detection close to critical structures such as the heart or liver. Specifically, we propose the use of an automatic feature extraction method in combination with the acquisition of fast orthogonal cine MRI images of nine lung patients. As a preliminary test, we evaluated the performance of the feature extraction method by applying it on regions of interest around (i) the diaphragm and (ii) the tumor and comparing the estimated motion with that obtained by (i) the extraction of the diaphragm profile and (ii) the segmentation of the tumor, respectively. The results confirmed the capability of the proposed method in quantifying tumor motion. Then, a point-based rigid registration was applied to the extracted tumor features between all frames to account for rotation. The median lung rotation values were -0.6 ± 2.3° and -1.5 ± 2.7° in the sagittal and coronal planes respectively, confirming the need to account for tumor rotation along with translation to improve radiotherapy treatment.
Midulla, Marco; Moreno, Ramiro; Baali, Adil; Chau, Ming; Negre-Salvayre, Anne; Nicoud, Franck; Pruvo, Jean-Pierre; Haulon, Stephan; Rousseau, Hervé
2012-10-01
In the last decade, there was been increasing interest in finding imaging techniques able to provide a functional vascular imaging of the thoracic aorta. The purpose of this paper is to present an imaging method combining magnetic resonance imaging (MRI) and computational fluid dynamics (CFD) to obtain a patient-specific haemodynamic analysis of patients treated by thoracic endovascular aortic repair (TEVAR). MRI was used to obtain boundary conditions. MR angiography (MRA) was followed by cardiac-gated cine sequences which covered the whole thoracic aorta. Phase contrast imaging provided the inlet and outlet profiles. A CFD mesh generator was used to model the arterial morphology, and wall movements were imposed according to the cine imaging. CFD runs were processed using the finite volume (FV) method assuming blood as a homogeneous Newtonian fluid. Twenty patients (14 men; mean age 62.2 years) with different aortic lesions were evaluated. Four-dimensional mapping of velocity and wall shear stress were obtained, depicting different patterns of flow (laminar, turbulent, stenosis-like) and local alterations of parietal stress in-stent and along the native aorta. A computational method using a combined approach with MRI appears feasible and seems promising to provide detailed functional analysis of thoracic aorta after stent-graft implantation. • Functional vascular imaging of the thoracic aorta offers new diagnostic opportunities • CFD can model vascular haemodynamics for clinical aortic problems • Combining CFD with MRI offers patient specific method of aortic analysis • Haemodynamic analysis of stent-grafts could improve clinical management and follow-up.
Fetterly, Kenneth A
2010-11-01
Minimizing the x-ray radiation dose is an important aspect of patient safety during interventional fluoroscopy procedures. This work investigates the practical aspects of an additional 0.1 mm Cu x-ray beam spectral filter applied to cine acquisition mode imaging on patient dose and image quality. Measurements were acquired using clinical interventional imaging systems. Acquisition images of Solid Water phantoms (15-40 cm) were acquired using x-ray beams with the x-ray tube inherent filtration and using an additional 0.1 mm Cu x-ray beam spectral filter. The skin entrance air kerma (dose) rate was measured and the signal difference to noise ratio (SDNR) of an iodine target embedded into the phantom was calculated to assess image quality. X-ray beam parameters were recorded and analyzed and a primary x-ray beam simulation was performed to assess additional x-ray tube burden attributable to the Cu filter. For all phantom thicknesses, the 0.1 mm Cu filter resulted in a 40% reduction in the entrance air kerma rate to the phantoms and a 9% reduction in the SDNR of the iodine phantom. The expected additional tube load required by the 0.1 mm Cu filter ranged from 11% for a 120 kVp x-ray beam to 43% for a 60 kVp beam. For these clinical systems, use of the 0.1 mm Cu filter resulted in a favorable compromise between reduced skin dose rate and image quality and increased x-ray tube burden.
Automatic evaluation of the Valsalva sinuses from cine-MRI
NASA Astrophysics Data System (ADS)
Blanchard, Cédric; Sliwa, Tadeusz; Lalande, Alain; Mohan, Pauliah; Bouchot, Olivier; Voisin, Yvon
2011-03-01
MRI appears to be particularly attractive for the study of the Sinuses of Valsalva (SV), however there is no global consensus on their suitable measurements. In this paper, we propose a new method, based on the mathematical morphology and combining a numerical geodesic reconstruction with an area estimation, to automatically evaluate the SV from a cine-MRI in a cross-sectional orientation. It consists in the extraction of the shape of the SV, the detection of relevant points (commissures, cusps and the centre of the SV), the measurement of relevant distances and in a classification of the valve as bicuspid or tricuspid by a metric evaluation of the SV. Our method was tested on 23 patient examinations and radii calculations were compared with a manual measurement. The classification of the valve as tricuspid or bicuspid was correct for all the cases. Moreover, there are an excellent correlation and an excellent concordance between manual and automatic measurements for images at diastolic phase (r= 0.97; y = x - 0.02; p=NS; mean of differences = -0.1 mm; standard deviation of differences = 2.3 mm) and at systolic phase (r= 0.96; y = 0.97 x + 0.80; p=NS ; mean of differences = -0.1 mm; standard deviation of differences = 2.4 mm). The cross-sectional orientation of the image acquisition plane conjugated with our automatic method provides a reliable morphometric evaluation of the SV, based on the automatic location of the centre of the SV, the commissure and the cusp positions. Measurements of distances between relevant points allow a precise evaluation of the SV.
Suwa, Kenichiro; Satoh, Hiroshi; Sano, Makoto; Nobuhara, Mamoru; Saitoh, Takeji; Saotome, Masao; Urushida, Tsuyoshi; Katoh, Hideki; Tawarahara, Kei; Ohtani, Hayato; Wakabayashi, Yasushi; Takase, Hiroyuki; Terada, Hajime; Takehara, Yasuo; Sakahara, Harumi; Hayashi, Hideharu
2014-01-01
Objective The prognosis of apical hypertrophic cardiomyopathy (APH) has been benign, but apical myocardial injury has prognostic importance. We studied functional, morphological and electrocardiographical abnormalities in patients with APH and with apical aneurysm and sought to find parameters that relate to apical myocardial injury. Methods Study design: a multicentre trans-sectional study. Patients: 45 patients with APH and 5 with apical aneurysm diagnosed with transthoracic echocardiography (TTE) in the database of Hamamatsu Circulation Forum. Measure: the apical contraction with cine-cardiac MR (CMR), the myocardial fibrotic scar with late gadolinium enhancement (LGE)-CMR, and QRS fragmentation (fQRS) defined when two ECG-leads exhibited RSR’s patterns. Results Cine-CMR revealed 27 patients with normal, 12 with hypokinetic and 11 with dyskinetic apical contraction. TTE misdiagnosed 11 (48%) patients with hypokinetic and dyskinetic contraction as those with normal contraction. Apical LGE was apparent in 10 (83%) and 11 (100%) patients with hypokinetic and dyskinetic contraction, whereas only in 11 patients (41%) with normal contraction (p<0.01). Patients with dyskinetic apical contraction had the lowest left ventricular ejection fraction, the highest prevalence of ventricular tachycardia, and the smallest ST depression and depth of negative T waves. The presence of fQRS was associated with impaired apical contraction and apical LGE (OR=8.32 and 8.61, p<0.05). Conclusions CMR is superior to TTE for analysing abnormalities of the apex in patients with APH and with apical aneurysm. The presence of fQRS can be a promising parameter for the early detection of apical myocardial injury. PMID:25332823
Imaging congenital heart disease in adults
Kilner, P J
2011-01-01
Transthoracic echocardiography is the first-line modality for cardiovascular imaging in adults with congenital heart disease (ACHD). The windows of access that are possible with transthoracic echocardiography are, however, rarely adequate for all regions of interest. The choice of further imaging depends on the clinical questions that remain to be addressed. The strengths of MRI include comprehensive access and coverage, providing imaging of all parts of the right ventricle, the pulmonary arteries, pulmonary veins and aorta. Cine images and velocity maps are acquired in specifically aligned planes, with stacks of cines or dynamic contrast angiography providing more comprehensive coverage. Tissues can be characterised if necessary, and MRI provides relatively accurate measurements of biventricular function and volume flow. These parameters are important in the assessment and follow-up of adults after repairs for tetralogy of Fallot or transposition of the great arteries and after Fontan operations. The superior spatial resolution and rapid acquisition of CT are invaluable in selected situations, including the visualisation of anomalous coronary or aortopulmonary collateral arteries, the assessment of luminal patency after stenting and imaging in patients with pacemakers. Ionising radiation is, however, a concern in younger patients who may need repeated investigation. Adults with relatively complex conditions should ideally be imaged in a specialist ACHD centre, where dedicated echocardiographic and cardiovascular MRI services are a necessary facility. General radiologists should be aware of the nature and pathophysiology of congenital heart disease, and should be alert for previously undiagnosed cases presenting in adulthood, including cases of atrial septal defect, aortic coarctation, patent ductus arteriosus, double-chambered right ventricle and congenitally corrected transposition. PMID:22723533
Bell, M R; Britson, P J; Chu, A; Holmes, D R; Bresnahan, J F; Schwartz, R S
1997-01-01
We describe a method of validation of computerized quantitative coronary arteriography and report the results of a new UNIX-based quantitative coronary arteriography software program developed for rapid on-line (digital) and off-line (digital or cinefilm) analysis. The UNIX operating system is widely available in computer systems using very fast processors and has excellent graphics capabilities. The system is potentially compatible with any cardiac digital x-ray system for on-line analysis and has been designed to incorporate an integrated database, have on-line and immediate recall capabilities, and provide digital access to all data. The accuracy (mean signed differences of the observed minus the true dimensions) and precision (pooled standard deviations of the measurements) of the program were determined x-ray vessel phantoms. Intra- and interobserver variabilities were assessed from in vivo studies during routine clinical coronary arteriography. Precision from the x-ray phantom studies (6-In. field of view) for digital images was 0.066 mm and for digitized cine images was 0.060 mm. Accuracy was 0.076 mm (overestimation) for digital images compared to 0.008 mm for digitized cine images. Diagnostic coronary catheters were also used for calibration; accuracy.varied according to size of catheter and whether or not they were filled with iodinated contrast. Intra- and interobserver variabilities were excellent and indicated that coronary lesion measurements were relatively user-independent. Thus, this easy to use and very fast UNIX based program appears to be robust with optimal accuracy and precision for clinical and research applications.
Prediction of severe thunderstorms over Sriharikota Island by using the WRF-ARW operational model
NASA Astrophysics Data System (ADS)
Papa Rao, G.; Rajasekhar, M.; Pushpa Saroja, R.; Sreeshna, T.; Rajeevan, M.; Ramakrishna, S. S. V. S.
2016-05-01
Operational short range prediction of Meso-scale thunderstorms for Sriharikota(13.7°N ,80.18°E) has been performed using two nested domains 27 & 9Km configuration of Weather Research & Forecasting-Advanced Research Weather Model (WRF- ARW V3.4).Thunderstorm is a Mesoscale system with spatial scale of few kilometers to a couple of 100 kilometers and time scale of less than an one hour to several hours, which produces heavy rain, lightning, thunder, surface wind squalls and down-bursts. Numerical study of Thunderstorms at Sriharikota and its neighborhood have been discussed with its antecedent thermodynamic stability indices and Parameters that are usually favorable for the development of convective instability based on WRF ARW model predictions. Instability is a prerequisite for the occurrence of severe weather, the greater the instability, the greater will be the potential of thunderstorm. In the present study, K Index, Total totals Index (TTI), Convective Available Potential Energy (CAPE), Convective Inhibition Energy (CINE), Lifted Index (LI), Precipitable Water (PW), etc. are the instability indices used for the short range prediction of thunderstorms. In this study we have made an attempt to estimate the skill of WRF ARW predictability and diagnosed three thunderstorms that occurred during the late evening to late night of 31st July, 20th September and 2nd October of 2015 over Sriharikota Island which are validated with Local Electric Field Mill (EFM), rainfall observations and Chennai Doppler Weather Radar products. The model predicted thermodynamic indices (CAPE, CINE, K Index, LI, TTI and PW) over Sriharikota which act as good indicators for severe thunderstorm activity.
Multishot EPI-SSFP in the heart.
Herzka, Daniel A; Kellman, Peter; Aletras, Anthony H; Guttman, Michael A; McVeigh, Elliot R
2002-04-01
Refocused steady-state free precession (SSFP), or fast imaging with steady precession (FISP or TrueFISP), has recently proven valuable for cardiac imaging because of its high signal-to-noise ratio (SNR) and excellent blood-myocardium contrast. In this study, various implementations of multiecho SSFP or EPI-SSFP for imaging in the heart are presented. EPI-SSFP has higher scan-time efficiency than single-echo SSFP, as two or more phase-encode lines are acquired per repetition time (TR) at the cost of a modest increase in TR. To minimize TR, a noninterleaved phase-encode order in conjunction with a phased-array ghost elimination (PAGE) technique was employed, removing the need for echo time shifting (ETS). The multishot implementation of EPI-SSFP was used to decrease the breath-hold duration for cine acquisitions or to increase the temporal or spatial resolution for a fixed breath-hold duration. The greatest gain in efficiency was obtained with the use of a three-echo acquisition. Image quality for cardiac cine applications using multishot EPI-SSFP was comparable to that of single-echo SSFP in terms of blood-myocardium contrast and contrast-to-noise ratio (CNR). The PAGE method considerably reduced flow artifacts due to both the inherent ghost suppression and the concomitant reduction in phase-encode blip size. The increased TR of multishot EPI-SSFP led to a reduced specific absorption rate (SAR) for a fixed RF flip angle, and allowed the use of a larger flip angle without increasing the SAR above the FDA-approved limits. Copyright 2002 Wiley-Liss, Inc.
Iacucci, Ilaria; Carbone, Iacopo; Cannavale, Giuseppe; Conti, Bettina; Iampieri, Ilaria; Rosati, Riccardo; Sardella, Gennaro; Frustaci, Andrea; Fedele, Francesco; Catalano, Carlo; Francone, Marco
2013-12-01
The main hallmark of Takotsubo cardiomyopathy (TT-CMP) is transient ischaemia, with completely reversible regional contractile dysfunction, which involves the mid-apical segments and shows no angiographic signs of coronary artery disease (CAD). The acute and reversible myocardial injury suggests that tissue oedema may be an important marker of disease. Seventeen patients with a clinical and angiographic diagnosis of TT-CMP underwent cardiovascular magnetic resonance (CMR) imaging in the acute phase and at follow-up after 4 months. A standard acquisition protocol including turbo spin echo (TSE) T2-weighted short-tau inversion-recovery (T2 STIR), steady-state free-precession cine (SSFP cine) and lateenhancement (LE) imaging after gadolinium benzyloxypropionic tetraacetic acid (Gd-BOPTA) administration was performed. All images were analysed, and data on oedema and LE were correlated with regional dysfunction and histological findings from endomyocardial biopsy (EMB) where available. In all patients, T2 STIR images showed a diffuse homogeneous hyperintensity that extended to all mid-apical segments and perfectly matched the area of regional dysfunction, reflecting tissue oedema. In the five patients who underwent EMB, histology confirmed the massive interstitial oedema associated with typical contraction-band necrosis. No cases of LE were observed. At follow-up, complete regression of oedema was observed in all cases, with significant recovery of regional and global left ventricular (LV) function (ejection fraction from 48.7% to 59.8%). Myocardial oedema on CMR is a characteristic feature of acute TT-CMP, which reflects acute inflammation and acute myocardial injury. It could therefore be used as a specific marker of disease severity.
NASA Astrophysics Data System (ADS)
Smolikova, Renata; Wachowiak, Mark P.; Drangova, Maria
2004-05-01
Interventional cardiac magnetic resonance (MR) procedures are the subject of an increasing number of research studies. Typically, during the procedure only two-dimensional images of oblique slices can be presented to the interventionalist in real time. There is a clear benefit to being able to register the real-time 2D slices to a previously acquired 3D computed tomography (CT) or MR image of the heart. Results from a study of the accuracy of registration of 2D cardiac images of an anesthetized pig to a 3D volume obtained in diastole are presented. Fast cine MR images representing twenty phases of the cardiac cycle were obtained of a 2D slice in a known oblique orientation. The 2D images were initially mis-oriented at distances ranging from 2 to 20 mm, and rotations of +/-10 degrees about all three axes. Images from all 20 cardiac phases were registered to examine the effect of timing between the 2D image and the 3D pre-procedural image. Linear registration using mutual information computed with 64 histogram bins yielded the highest accuracy. For the diastolic phases, mean translation and rotation errors ranged between 0.91 and 1.32 mm and between 1.73 and 2.10 degrees. Scans acquired at other phases also had high accuracy. These results are promising for the use of real time MR in image-guided cardiac interventions, and demonstrate the feasibility of registering 2D oblique MR slices to previously acquired single-phase volumes without preprocessing.
3D deformable organ model based liver motion tracking in ultrasound videos
NASA Astrophysics Data System (ADS)
Kim, Jung-Bae; Hwang, Youngkyoo; Oh, Young-Taek; Bang, Won-Chul; Lee, Heesae; Kim, James D. K.; Kim, Chang Yeong
2013-03-01
This paper presents a novel method of using 2D ultrasound (US) cine images during image-guided therapy to accurately track the 3D position of a tumor even when the organ of interest is in motion due to patient respiration. Tracking is possible thanks to a 3D deformable organ model we have developed. The method consists of three processes in succession. The first process is organ modeling where we generate a personalized 3D organ model from high quality 3D CT or MR data sets captured during three different respiratory phases. The model includes the organ surface, vessel and tumor, which can all deform and move in accord with patient respiration. The second process is registration of the organ model to 3D US images. From 133 respiratory phase candidates generated from the deformable organ model, we resolve the candidate that best matches the 3D US images according to vessel centerline and surface. As a result, we can determine the position of the US probe. The final process is real-time tracking using 2D US cine images captured by the US probe. We determine the respiratory phase by tracking the diaphragm on the image. The 3D model is then deformed according to respiration phase and is fitted to the image by considering the positions of the vessels. The tumor's 3D positions are then inferred based on respiration phase. Testing our method on real patient data, we have found the accuracy of 3D position is within 3.79mm and processing time is 5.4ms during tracking.
Patel, Rajan P; Sitton, Clark W; Ketonen, Leena M; Hou, Ping; Johnson, Jason M; Romo, Seferino; Fletcher, Stephen; Shah, Manish N; Kerr, Marcia; Zaky, Wafik; Rytting, Michael E; Khatua, Soumen; Sandberg, David I
2018-03-01
Nuclear medicine studies have previously been utilized to assess for blockage of cerebrospinal fluid (CSF) flow prior to intraventricular chemotherapy infusions. To assess CSF flow without nuclear medicine studies, we obtained cine phase-contrast MRI sequences that assess CSF flow from the fourth ventricle down to the sacrum. In three clinical trials, 18 patients with recurrent malignant posterior fossa tumors underwent implantation of a ventricular access device (VAD) into the fourth ventricle, either with or without simultaneous tumor resection. Prior to infusing therapeutic agents into the VAD, cine MRI phase-contrast CSF flow sequences of the brain and total spine were performed. Velocity encoding (VENC) of 5 and 10 cm/s was used to confirm CSF flow from the fourth ventricular outlets to the cervical, thoracic, and lumbar spine. Qualitative CSF flow was characterized by neuroradiologists as present or absent. All 18 patients demonstrated CSF flow from the outlets of the fourth ventricle down to the sacrum with no evidence of obstruction. One of these patients, after disease progression, subsequently showed obstruction of CSF flow. No patient required a nuclear medicine study to assess CSF flow prior to initiation of infusions. Fourteen patients have received infusions to date, and none has had neurological toxicity. CSF flow including the fourth ventricle and the total spine can be assessed noninvasively with phase-contrast MRI sequences. Advantages over nuclear medicine studies include avoiding both an invasive procedure and radiation exposure.
1980-03-01
full-color terrain model designed to 6 ,. .. ., CINE MA ICiINE h MRO FILM To’ N U Ix v M C CTMIRROR MONITOR FRESNEL REAR- PROJECTION SCREEN Z...ments of NOE flight, recorded on videotape. One segment was filmed at the Hunter-Liggett, Calif., ntilitary reservation, and the other segment was... filmed near Fort Rucker, Ala. The tapes were viewed by each participant pilot on the 13-cm and the 26-cm CRT displays. They could attenuate the display
2009-01-01
eczema accinatum and progressive vaccinia in individuals such as eczema ufferers and the immunocompromised, caused concerns about the accine and prompted...aerosolized RPXV under conditions as previously described [13]. Briefly, the respira- tory function of each rabbit was first measured using whole-body...using respiratory minute volume (Vm) estimates derived from the respiratory function mea- 5 cine 2 s d e o f 2 m p 2 s o c b a w a k w 2 o s t s b s w t
Aeromedical Disposition and Waiver Consideration for ISS Crewmembers
NASA Technical Reports Server (NTRS)
Taddeo, Terrance
2012-01-01
Aeromedical certification of astronauts and cosmonauts traveling to the International Space Station is a multi?-tiered process that involv es standards agreed to by the partner agencies, and participation by the individual agency aeromedical boards and a multilateral space medi cine board. Medical standards are updated continually by a multilater al working group. The boards operate by consensus and strive to achie ve effective decision making through experience, medical judgment, medical evidence and risk modeling. The aim of the certification process is to minimize the risk to the ISS program of loss of mission object ives due to human health issues.
Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico
2017-04-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.
New High Index Optical Glasses
NASA Astrophysics Data System (ADS)
Blair, Gerald E.; Greco, Edgar J.; DeJager, Donald; Wylot, James M.
1982-02-01
The pioneering work of Charles W. Frederick and George W. Morey on the design by Frederick of an "ideal photographic lens" using hypothetical glasses, and the subsequent discovery and development of rare-element borate glasses by Morey, has been resumed at Eastman Kodak. New ultra-high index, low dispersion crown glasses and companion flint glasses have been developed, based on the needs dictated by lens design studies for novel fast cine' and still camera lenses. These new glasses reduce the number of elements required in a lens while maintaining or improving lens performance. Composition studies leading to these new glasses will be discussed.
Development of a DICOM library
NASA Astrophysics Data System (ADS)
Kim, Dongsun; Shin, Dongkyu M.; Kim, Dongyoun M.
2001-08-01
Object-oriented DICOM decoding library was developed as a type of DLL for MS-Windows environment development. It supports all DICOM standard Transfer Syntaxes, multi-frame images, RLE decoding and window level adjusting. Image library for medical application was also developed as a type of DLL and ActiveX Control using proposed DICOM library. It supports display of DICOM image, cine mode and basic manipulations. For an application of a proposed image library, a couple of DICOM viewers were developed. One can be used as an off-line DICOM Workstation, and the other can be used for browsing the local DICOM files.
Apical hypertrophy associated with rapid T wave inversion on the electrocardiogram.
Yamanari, H; Saito, D; Mikio, K; Nakamura, K; Nanba, T; Morita, H; Mizuo, K; Sato, T; Ohe, T
1995-01-01
A 53-year-old man who had no chest pain and no family history of heart disease demonstrated a rapid T wave change on an electrocardiogram, from a positive T wave to a giant negative T wave, within 1 year. Echocardiography showed no left ventricular hypertrophy before or after the T wave change. Cine-magnetic resonance imaging revealed focal apical hypertrophy after the appearance of the giant negative T wave. Although T wave inversions sometimes develop within a short period in patients with hypertrophic cardiomyopathy, they are rare in a patient without hypertension or chest pain.
Clinical experience with a high-performance ATM-connected DICOM archive for cardiology
NASA Astrophysics Data System (ADS)
Solomon, Harry P.
1997-05-01
A system to archive large image sets, such as cardiac cine runs, with near realtime response must address several functional and performance issues, including efficient use of a high performance network connection with standard protocols, an architecture which effectively integrates both short- and long-term mass storage devices, and a flexible data management policy which allows optimization of image distribution and retrieval strategies based on modality and site-specific operational use. Clinical experience with such as archive has allowed evaluation of these systems issues and refinement of a traffic model for cardiac angiography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rozen, P.; Gelfond, M.; Zaltzman, S.
1982-08-01
The esophagus was evaluated in 15 patients with achalasia by continuous gamma camera imaging following ingestion of a semi-solid meal labeled with /sup 99//sup m/Tc. The images were displayed and recorded on a simple computerized data processing/display system. Subsequent cine' mode images of esophagela emptying demonstrated abnormalities of the body of the esophagus not reflected by the manometric examination. Computer-generated time-activity curves representing specific regions of interest were better than manometry in evaluating the results of myotomy, dilatation, and drug therapy. Isosorbide dinitrate significantly improved esophageal emptying.
Kim, Jung-In; Lee, Hanyoung; Wu, Hong-Gyun; Chie, Eui Kyu; Kang, Hyun-Cheol; Park, Jong Min
2017-09-01
The aim of this study is to develop a visual guidance patient-controlled (VG-PC) respiratory gating system for respiratory-gated magnetic-resonance image-guided radiation therapy (MR-IGRT) and to evaluate the performance of the developed system. The near-real-time cine planar MR image of a patient acquired during treatment was transmitted to a beam projector in the treatment room through an optical fiber cable. The beam projector projected the cine MR images inside the bore of the ViewRay system in order to be visible to a patient during treatment. With this visual information, patients voluntarily controlled their respiration to put the target volume into the gating boundary (gating window). The effect of the presence of the beam projector in the treatment room on the image quality of the MRI was investigated by evaluating the signal-to-noise ratio (SNR), uniformity, low-contrast detectability, high-contrast spatial resolution, and spatial integrity with the VG-PC gating system. To evaluate the performance of the developed system, we applied the VG-PC gating system to a total of seven patients; six patients received stereotactic ablative radiotherapy (SABR) and one patient received conventional fractionated radiation therapy. The projected cine MR images were visible even when the room light was on. No image data loss or additional time delay during delivery of image data were observed. Every indicator representing MRI quality, including SNR, uniformity, low-contrast detectability, high-contrast spatial resolution, and spatial integrity exhibited values higher than the tolerance levels of the manufacturer with the VG-PC gating system; therefore, the presence of the VG-PC gating system in the treatment room did not degrade the MR image quality. The average beam-off times due to respiratory gating with and without the VG-PC gating system were 830.3 ± 278.2 s and 1264.2 ± 302.1 s respectively (P = 0.005). Consequently, the total treatment times excluding the time for patient setup with and without the VG-PC gating system were 1453.3 ± 297.3 s and 1887.2 ± 469.6 s, respectively, on average (P = 0.005). The average number of beam-off events during whole treatment session was reduced from 457 ± 154 times to 195 ± 90 times by using the VG-PC gating system (P < 0.001). The developed system could improve treatment efficiency when performing respiratory-gated MR-IGRT. The VG-PC gating system could be applied to any kind of bore-type radiotherapy machine. © 2017 American Association of Physicists in Medicine.
Cine-servo lens technology for 4K broadcast and cinematography
NASA Astrophysics Data System (ADS)
Nurishi, Ryuji; Wakazono, Tsuyoshi; Usui, Fumiaki
2015-09-01
Central to the rapid evolution of 4K image capture technology in the past few years, deployment of large-format cameras with Super35mm Single Sensors is increasing in TV production for diverse shows such as dramas, documentaries, wildlife, and sports. While large format image capture has been the standard in the cinema world for quite some time, the recent experiences within the broadcast industry have revealed a variety of requirement differences for large format lenses compared to those of the cinema industry. A typical requirement for a broadcast lens is a considerably higher zoom ratio in order to avoid changing lenses in the middle of a live event, which is mostly not the case for traditional cinema productions. Another example is the need for compact size, light weight, and servo operability for a single camera operator shooting in a shoulder-mount ENG style. On the other hand, there are new requirements that are common to both worlds, such as smooth and seamless change in angle of view throughout the long zoom range, which potentially offers new image expression that never existed in the past. This paper will discuss the requirements from the two industries of cinema and broadcast, while at the same time introducing the new technologies and new optical design concepts applied to our latest "CINE-SERVO" lens series which presently consists of two models, CN7x17KAS-S and CN20x50IAS-H. It will further explain how Canon has realized 4K optical performance and fast servo control while simultaneously achieving compact size, light weight and high zoom ratio, by referring to patent-pending technologies such as the optical power layout, lens construction, and glass material combinations.
Pilot program on patient dosimetry in pediatric interventional cardiology in Chile
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ubeda, Carlos; Vano, Eliseo; Miranda, Patricia
2012-05-15
Purpose: The aim of this study was to present the results of a pilot program on patient dosimetry carried out in Chile during the last 5 yr, using a biplane x-ray angiography system settled for pediatrics. This research was conducted in Latin America under the auspices of the International Atomic Energy Agency (IAEA) supporting programs on radiological protection (RP) of patients. Methods: Patient age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time, and two dosimetric quantities [air kerma-area product (P{sub ka}) and cumulative dose (CD) at the patient entrance reference point] were recorded formore » each procedure. Results: The study includes 544 patients grouped into four age groups. The distributions by age group were 150 for <1 yr; 203 for 1 to <5 yr; 97 for 5 to <10 yr; and 94 for 10 to <16 yr. Median values of P{sub ka} and CD for the four age groups were 0.94, 1.46, 2.13, and 5.03 Gy cm{sup 2} and 23.9, 26.8, 33.5, and 51.6 mGy, respectively. No significant statistical differences were found between diagnostic and therapeutic procedures. A moderate correlation (r = 0.64) was seen between P{sub ka} and patient weight. Conclusions: The dose values reported in this paper were lower than those published in the previous work for the same age groups as a result of the optimization actions carried out by cardiologists and medical physicists with the support of the IAEA. Methodology and results will be used as a starting point for a wider survey in Chile and Latin America with the goal to obtain regional diagnostic reference levels as recently recommended by the International Commission on Radiological Protection for interventional procedures.« less
Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI.
Zhang, Wei; Bogale, Saivivek; Golriz, Farahnaz; Krishnamurthy, Rajesh
2017-11-01
Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole.
Reproducibility of CT Perfusion Parameters in Liver Tumors and Normal Liver
Ng, Chaan S.; Chandler, Adam G.; Wei, Wei; Herron, Delise H.; Anderson, Ella F.; Kurzrock, Razelle; Charnsangavej, Chusilp
2011-01-01
Purpose: To assess the reproducibility of computed tomographic (CT) perfusion measurements in liver tumors and normal liver and effects of motion and data acquisition time on parameters. Materials and Methods: Institutional review board approval and written informed consent were obtained for this prospective study. The study complied with HIPAA regulations. Two CT perfusion scans were obtained 2–7 days apart in seven patients with liver tumors with two scanning phases (phase 1: 30-second breath-hold cine; phase 2: six intermittent free-breathing cines) spanning 135 seconds. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability–surface area product (PS) for tumors and normal liver were calculated from phase 1 with and without rigid registration and, for combined phases 1 and 2, with manually and rigid-registered phase 2 images, by using deconvolution modeling. Variability was assessed with within-patient coefficients of variation (CVs) and Bland-Altman analyses. Results: For tumors, BF, BV, MTT, and PS values and reproducibility varied by analytical method, the former by up to 11%, 23%, 21%, and 138%, respectively. Median PS values doubled with the addition of phase 2 data to phase 1 data. The best overall reproducibility was obtained with rigidly registered phase 1 and phase 2 images, with within-patient CVs for BF, BV, MTT, and PS of 11.2%, 14.4%, 5.5% and 12.1%, respectively. Normal liver evaluations were similar, except with marginally lower variability. Conclusion: Absolute values and reproducibility of CT perfusion parameters were markedly influenced by motion and data acquisition time. PS, in particular, probably requires data acquisition beyond a single breath hold, for which motion-correction techniques are likely necessary. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11110331/-/DC1 PMID:21788525
Contijoch, Francisco; Witschey, Walter R T; Rogers, Kelly; Rears, Hannah; Hansen, Michael; Yushkevich, Paul; Gorman, Joseph; Gorman, Robert C; Han, Yuchi
2015-05-21
Data obtained during arrhythmia is retained in real-time cardiovascular magnetic resonance (rt-CMR), but there is limited and inconsistent evidence to show that rt-CMR can accurately assess beat-to-beat variation in left ventricular (LV) function or during an arrhythmia. Multi-slice, short axis cine and real-time golden-angle radial CMR data was collected in 22 clinical patients (18 in sinus rhythm and 4 patients with arrhythmia). A user-initialized active contour segmentation (ACS) software was validated via comparison to manual segmentation on clinically accepted software. For each image in the 2D acquisitions, slice volume was calculated and global LV volumes were estimated via summation across the LV using multiple slices. Real-time imaging data was reconstructed using different image exposure times and frame rates to evaluate the effect of temporal resolution on measured function in each slice via ACS. Finally, global volumetric function of ectopic and non-ectopic beats was measured using ACS in patients with arrhythmias. ACS provides global LV volume measurements that are not significantly different from manual quantification of retrospectively gated cine images in sinus rhythm patients. With an exposure time of 95.2 ms and a frame rate of > 89 frames per second, golden-angle real-time imaging accurately captures hemodynamic function over a range of patient heart rates. In four patients with frequent ectopic contractions, initial quantification of the impact of ectopic beats on hemodynamic function was demonstrated. User-initialized active contours and golden-angle real-time radial CMR can be used to determine time-varying LV function in patients. These methods will be very useful for the assessment of LV function in patients with frequent arrhythmias.
Jaeger, Matthias; Khoo, Angela K; Conforti, David A; Cuganesan, Ramesh
2016-11-01
Phase contrast cine MRI with determination of pulsatile aqueductal cerebrospinal fluid (CSF) stroke volume and flow velocity has been suggested to assess intracranial pulsations in idiopathic normal pressure hydrocephalus (iNPH). We aimed to compare this non-invasive measure of pulsations to intracranial pressure (ICP) pulse wave amplitude from continuous ICP monitoring. We hypothesised that a significant correlation between these two markers of intracranial pulsations exists. Fifteen patients with suspected iNPH had continuous computerised ICP monitoring with calculation of mean ICP pulse wave amplitude (MWA) from time-domain analysis. MRI measured CSF aqueductal stroke volume and peak flow velocity. Mean MWA was 5.4mmHg (range 2.3-12.4mmHg). Mean CSF stroke volume and peak flow velocity were 65μl (range 3-195μl) and 9.31cm/s (range 1.68-15.0cm/s), respectively. No significant correlation between the invasive and non-invasive measures of pulsations existed (Spearman r=-0.30 and r=-0.27, respectively; p>0.05). We observed marked intra-individual fluctuation of MWA during continuous ICP monitoring of an average of 6.0mmHg (range 2.8-12.2mmHg). The results suggest a complex interplay between measures of pulsations derived from snapshot MRI measurements and continuous computerised ICP measurements, as no significant relationship existed in our data. Further study is needed to better understand the temporal profile of CSF MRI flow studies, as substantial variation in MWA over the course of several hours of ICP monitoring is common, suggesting that these physiologic fluctuations might obscure MRI snapshot measures of intracranial pulsations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Yamasaki, Yuzo; Nagao, Michinobu; Kamitani, Takeshi; Yamanouchi, Torahiko; Kawanami, Satoshi; Yamamura, Kenichiro; Sakamoto, Ichiro; Yabuuchi, Hidetake; Honda, Hiroshi
2016-10-01
To investigate the utility of eccentricity index (EI) using cardiac cine MRI for the assessment of right ventricular (RV) hemodynamics in congenital heart disease (CHD). Fifty-five patients with CHD (32 women; mean age, 40.7 ± 20.9 years) underwent both cardiac MRI and right heart catheterization. EI was defined as the ratio of the distance between the anterior-posterior wall and the septal-lateral wall measured in the short-axis of mid-ventricular cine MRI. Correlations between EIs and RV hemodynamic parameters were analyzed. EIs were compared between patients with and without late gadolinium enhancement (LGE). A strong correlation between mean pulmonary artery pressure (PAP) and systolic EI (r = 0.81, p < 0.0001) and a moderate negative correlation between diastolic EI and RV ejection fraction (EF) (r = -0.62, p < 0.0001) were observed. Receiver operating characteristic analysis revealed optimal EI thresholds for detecting patients with mean PAP ≥40 mmHg with C-statistics of 0.90 and patients with RVEF <40 % with C-statistics of 0.78. Systolic EIs were significantly greater for patients with LGE (1.45 ± 0.05) than for those without LGE (1.15 ± 0.07; p < 0.001). EI offers a simple, comprehensive index that can predict pulmonary hypertension and RV dysfunction in CHD. • EI offers a simple and comprehensive index of RV hemodynamics. • EI could predict pulmonary hypertension and RV dysfunction. • Left ventricular deformation expressed as high EI is related to myocardial fibrosis.
2013-01-01
Background Cardiovascular magnetic resonance (CMR) steady state free precession (SSFP) cine sequences with high temporal resolution and improved post-processing can accurately measure RA dimensions. We used this technique to define ranges for normal RA volumes and dimensions normalized, when necessary, to the influence of gender, body surface area (BSA) and age, and also to define the best 2D images-derived predictors of RA enlargement. Methods For definition of normal ranges of RA volume we studied 120 healthy subjects (60 men, 60 women; 20 subjects per age decile from 20 to 80 years), after careful exclusion of cardiovascular abnormality. We also studied 120 patients (60 men, 60 women; age range 20 to 80 years) with a clinical indication for CMR in order to define the best 1D and 2D predictors of RA enlargement. Data were generated from SSFP cine CMR, with 3-dimensional modeling, including tracking of the atrioventricular ring motion and time-volume curves analysis. Results In the group of healthy individuals, age influenced RA 2-chamber area and transverse diameter. Gender influenced most absolute RA dimensions and volume. Interestingly, right atrial volumes did not change with age and gender when indexed to body surface area. New CMR normal ranges for RA dimensions were modeled and displayed for clinical use with normalization for BSA and gender and display of parameter variation with age. Finally, the best 2D images-derived independent predictors of RA enlargement were indexed area and indexed longitudinal diameter in the 2-chamber view. Conclusion Reference RA dimensions and predictors of RA enlargement are provided using state-of-the-art CMR techniques. PMID:23566426
2010-01-01
Background Left atrial (LA) size is related to cardiovascular morbidity and mortality. Cardiovascular magnetic resonance (CMR) provides high quality images of the left atrium with high temporal resolution steady state free precession (SSFP) cine sequences. We used SSFP cines to define normal ranges for LA volumes and dimensions relative to gender, age and body surface area (BSA), and examine the relative value of 2D atrial imaging techniques in patients. For definition of normal ranges of LA volume we studied 120 healthy subjects after careful exclusion of cardiovascular abnormality (60 men, 60 women; 20 subjects per age decile from 20 to 80 years). Data were generated from 3-dimensional modeling, including tracking of the atrioventricular ring motion and time-volume curves analysis. For definition of the best 2D images-derived predictors of LA enlargement, we studied 120 patients (60 men, 60 women; age range 20 to 80 years) with a clinical indication for CMR. Results In the healthy subjects, age was associated with LA 4-chamber transverse and 3-chamber anteroposterior diameters, but not with LA volume. Gender was an independent predictor of most absolute LA dimensions and volume, but following normalization to BSA, some associations became non-significant. CMR normal ranges were modeled and are tabled for clinical use with normalization, where appropriate, for BSA and gender and display of parameter variation with age. The best 2D predictors of LA volume were the 2-chamber area and 3-chamber area (both r = 0.90, p < 0.001). Conclusions These CMR data show that LA dimensions and volume in healthy, individuals vary significantly by BSA, with lesser effects of age and gender. PMID:21070636
Guo, Xiaoya; Zhu, Jian; Maehara, Akiko; Monoly, David; Samady, Habib; Wang, Liang; Billiar, Kristen L.; Zheng, Jie; Yang, Chun; Mintz, Gary S.; Giddens, Don P.; Tang, Dalin
2016-01-01
Computational models have been used to calculate plaque stress and strain for plaque progression and rupture investigations. An intravascular ultrasound (IVUS)-based modeling approach is proposed to quantify in vivo vessel material properties for more accurate stress/strain calculations. In vivo Cine IVUS and VH-IVUS coronary plaque data were acquired from one patient with informed consent obtained. Cine IVUS data and 3D thin-slice models with axial stretch were used to determine patient-specific vessel material properties. Twenty full 3D fluid–structure interaction models with ex vivo and in vivo material properties and various axial and circumferential shrink combinations were constructed to investigate the material stiffness impact on stress/strain calculations. The approximate circumferential Young’s modulus over stretch ratio interval [1.0, 1.1] for an ex vivo human plaque sample and two slices (S6 and S18) from our IVUS data were 1631, 641, and 346 kPa, respectively. Average lumen stress/strain values from models using ex vivo, S6 and S18 materials with 5 % axial shrink and proper circumferential shrink were 72.76, 81.37, 101.84 kPa and 0.0668, 0.1046, and 0.1489, respectively. The average cap strain values from S18 material models were 150–180 % higher than those from the ex vivo material models. The corresponding percentages for the average cap stress values were 50–75 %. Dropping axial and circumferential shrink consideration led to stress and strain over-estimations. In vivo vessel material properties may be considerably softer than those from ex vivo data. Material stiffness variations may cause 50–75 % stress and 150–180 % strain variations. PMID:27561649
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alpuche Aviles, Jorge E.; VanBeek, Timothy
Purpose: This work presents an algorithm used to quantify intra-fraction motion for patients treated using deep inspiration breath hold (DIBH). The algorithm quantifies the position of the chest wall in breast tangent fields using electronic portal images. Methods: The algorithm assumes that image profiles, taken along a direction perpendicular to the medial border of the field, follow a monotonically and smooth decreasing function. This assumption is invalid in the presence of lung and can be used to calculate chest wall position. The algorithm was validated by determining the position of the chest wall for varying field edge positions in portalmore » images of a thoracic phantom. The algorithm was used to quantify intra-fraction motion in cine images for 7 patients treated with DIBH. Results: Phantom results show that changes in the distance between chest wall and field edge were accurate within 0.1 mm on average. For a fixed field edge, the algorithm calculates the position of the chest wall with a 0.2 mm standard deviation. Intra-fraction motion for DIBH patients was within 1 mm 91.4% of the time and within 1.5 mm 97.9% of the time. The maximum intra-fraction motion was 3.0 mm. Conclusions: A physics based algorithm was developed and can be used to quantify the position of chest wall irradiated in tangent portal images with an accuracy of 0.1 mm and precision of 0.6 mm. Intra-fraction motion for patients treated with DIBH at our clinic is less than 3 mm.« less
Öztürk, Ayşe; Cimrin, Arif Hikmet; Tür, Mahmut; Güven, Rana
2012-01-01
Problems in legal definition and diagnosis of occupational diseases in Turkey makes the diagnosis of these diseases and informing the parties important. For this purpose, this study was planned to elicit the frequency of silicosis in quartz mill workers in Cine which is one of the largest quartz and feldspat areas, and to detect the working conditions, to inform the workers to improve the working conditions. The aim was to evaluate 592 workers in 10 quartz mill and mines around Cine in 2004. A structured questionnaire including personal information and work-related questions was applied. Standards chest X-rays taken in the last six months were evaluated according to International Labour Organization (ILO) 1980 standards. Dust concentration and respirable dust concentration in the work place were measured in enterprises. The mean age of the workers was 31.8 ± 8.26 years and 71.7% was smoker. Duration of working was ≤ 5 years in 80.5% and ≥ 10 years in only 4.2%. According to the results of dust measurements, threshold value was found to be exceeded in chopping, packaging and bagging parts of three workplaces. Frequency of silicosis was calculated to be 23.7%. Frequency of pneumoconiosis was found to be high like previous studies carried out in similar workplaces in this study. Although it was impossible to put forward the cumulative effect of dust exposure because of frequent altering in workplace, the high frequency of working in similar workplaces among the cases supported the significant risk of silicosis in these enterprises. The workplaces were observed after the workers and persons responsible from occupational health and safety.
Patient-specific coronary blood supply territories for quantitative perfusion analysis
Zakkaroff, Constantine; Biglands, John D.; Greenwood, John P.; Plein, Sven; Boyle, Roger D.; Radjenovic, Aleksandra; Magee, Derek R.
2018-01-01
Abstract Myocardial perfusion imaging, coupled with quantitative perfusion analysis, provides an important diagnostic tool for the identification of ischaemic heart disease caused by coronary stenoses. The accurate mapping between coronary anatomy and under-perfused areas of the myocardium is important for diagnosis and treatment. However, in the absence of the actual coronary anatomy during the reporting of perfusion images, areas of ischaemia are allocated to a coronary territory based on a population-derived 17-segment (American Heart Association) AHA model of coronary blood supply. This work presents a solution for the fusion of 2D Magnetic Resonance (MR) myocardial perfusion images and 3D MR angiography data with the aim to improve the detection of ischaemic heart disease. The key contribution of this work is a novel method for the mediated spatiotemporal registration of perfusion and angiography data and a novel method for the calculation of patient-specific coronary supply territories. The registration method uses 4D cardiac MR cine series spanning the complete cardiac cycle in order to overcome the under-constrained nature of non-rigid slice-to-volume perfusion-to-angiography registration. This is achieved by separating out the deformable registration problem and solving it through phase-to-phase registration of the cine series. The use of patient-specific blood supply territories in quantitative perfusion analysis (instead of the population-based model of coronary blood supply) has the potential of increasing the accuracy of perfusion analysis. Quantitative perfusion analysis diagnostic accuracy evaluation with patient-specific territories against the AHA model demonstrates the value of the mediated spatiotemporal registration in the context of ischaemic heart disease diagnosis. PMID:29392098
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Danny; Greer, Peter B.; Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, NSW
Purpose: To assess the impact of an audiovisual (AV) biofeedback on intra- and interfraction tumor motion for lung cancer patients. Methods and Materials: Lung tumor motion was investigated in 9 lung cancer patients who underwent a breathing training session with AV biofeedback before 2 3T magnetic resonance imaging (MRI) sessions. The breathing training session was performed to allow patients to become familiar with AV biofeedback, which uses a guiding wave customized for each patient according to a reference breathing pattern. In the first MRI session (pretreatment), 2-dimensional cine-MR images with (1) free breathing (FB) and (2) AV biofeedback were obtained, andmore » the second MRI session was repeated within 3-6 weeks (mid-treatment). Lung tumors were directly measured from cine-MR images using an auto-segmentation technique; the centroid and outlier motions of the lung tumors were measured from the segmented tumors. Free breathing and AV biofeedback were compared using several metrics: intra- and interfraction tumor motion consistency in displacement and period, and the outlier motion ratio. Results: Compared with FB, AV biofeedback improved intrafraction tumor motion consistency by 34% in displacement (P=.019) and by 73% in period (P<.001). Compared with FB, AV biofeedback improved interfraction tumor motion consistency by 42% in displacement (P<.046) and by 74% in period (P=.005). Compared with FB, AV biofeedback reduced the outlier motion ratio by 21% (P<.001). Conclusions: These results demonstrated that AV biofeedback significantly improved intra- and interfraction lung tumor motion consistency for lung cancer patients. These results demonstrate that AV biofeedback can facilitate consistent tumor motion, which is advantageous toward achieving more accurate medical imaging and radiation therapy procedures.« less
Computing group cardinality constraint solutions for logistic regression problems.
Zhang, Yong; Kwon, Dongjin; Pohl, Kilian M
2017-01-01
We derive an algorithm to directly solve logistic regression based on cardinality constraint, group sparsity and use it to classify intra-subject MRI sequences (e.g. cine MRIs) of healthy from diseased subjects. Group cardinality constraint models are often applied to medical images in order to avoid overfitting of the classifier to the training data. Solutions within these models are generally determined by relaxing the cardinality constraint to a weighted feature selection scheme. However, these solutions relate to the original sparse problem only under specific assumptions, which generally do not hold for medical image applications. In addition, inferring clinical meaning from features weighted by a classifier is an ongoing topic of discussion. Avoiding weighing features, we propose to directly solve the group cardinality constraint logistic regression problem by generalizing the Penalty Decomposition method. To do so, we assume that an intra-subject series of images represents repeated samples of the same disease patterns. We model this assumption by combining series of measurements created by a feature across time into a single group. Our algorithm then derives a solution within that model by decoupling the minimization of the logistic regression function from enforcing the group sparsity constraint. The minimum to the smooth and convex logistic regression problem is determined via gradient descent while we derive a closed form solution for finding a sparse approximation of that minimum. We apply our method to cine MRI of 38 healthy controls and 44 adult patients that received reconstructive surgery of Tetralogy of Fallot (TOF) during infancy. Our method correctly identifies regions impacted by TOF and generally obtains statistically significant higher classification accuracy than alternative solutions to this model, i.e., ones relaxing group cardinality constraints. Copyright © 2016 Elsevier B.V. All rights reserved.
Suever, Jonathan D; Wehner, Gregory J; Jing, Linyuan; Powell, David K; Hamlet, Sean M; Grabau, Jonathan D; Mojsejenko, Dimitri; Andres, Kristin N; Haggerty, Christopher M; Fornwalt, Brandon K
2017-01-01
Mechanics of the left ventricle (LV) are important indicators of cardiac function. The role of right ventricular (RV) mechanics is largely unknown due to the technical limitations of imaging its thin wall and complex geometry and motion. By combining 3D Displacement Encoding with Stimulated Echoes (DENSE) with a post-processing pipeline that includes a local coordinate system, it is possible to quantify RV strain, torsion, and synchrony. In this study, we sought to characterize RV mechanics in 50 healthy individuals and compare these values to their LV counterparts. For each cardiac frame, 3D displacements were fit to continuous and differentiable radial basis functions, allowing for the computation of the 3D Cartesian Lagrangian strain tensor at any myocardial point. The geometry of the RV was extracted via a surface fit to manually delineated endocardial contours. Throughout the RV, a local coordinate system was used to transform from a Cartesian strain tensor to a polar strain tensor. It was then possible to compute peak RV torsion as well as peak longitudinal and circumferential strain. A comparable analysis was performed for the LV. Dyssynchrony was computed from the standard deviation of regional activation times. Global circumferential strain was comparable between the RV and LV (−18.0% for both) while longitudinal strain was greater in the RV (−18.1% vs. −15.7%). RV torsion was comparable to LV torsion (6.2 vs. 7.1 degrees, respectively). Regional activation times indicated that the RV contracted later but more synchronously than the LV. 3D spiral cine DENSE combined with a post–processing pipeline that includes a local coordinate system can resolve both the complex geometry and 3D motion of the RV. PMID:28055859
Sharma, Ashwani Kumar; Gaikwad, Shailesh; Gupta, Vipul; Garg, Ajay; Mishra, Nalini K
2008-04-01
Since it was first described, normal pressure hydrocephalus (NPH) and its treatment by means of cerebrospinal fluid (CSF) shunting have been the focus of much investigation. Whatever be the cause of NPH, it has been hypothesized that in this disease there occurs decreased arterial expansion and an increased brain expansion leading to increased transmantle pressure. We cannot measure the latter, but fortunately the effect of these changes (increased peak flow velocity through the aqueduct) can be quantified with cine phase-contrast magnetic resonance imaging (MRI). This investigation was thus undertaken to characterize and measure CSF peak flow velocity at the level of the aqueduct, before and after lumbar CSF drainage, by means of a phase-contrast cine MRI and determine its role in selecting cases for shunt surgery. 37 patients with clinically suspected NPH were included in the study. Changes in the hyperdynamic peak CSF flow velocity with 50 ml lumbar CSF drainage (mimicking shunt) were evaluated in them for considering shunt surgery. 14 out of 15 patients who were recommended for shunt surgery, based on changes peak flow velocity after lumbar CSF drainage, improved after shunt surgery. None of the cases which were not recommended for shunt surgery, based on changes in CSF peak flow velocity after lumbar CSF drainage, improved after shunt surgery (2 out of 22 cases). The study concluded that the phase-contrast MR imaging, done before and after CSF drainage, is a sensitive method to support the clinical diagnosis of normal pressure hydrocephalus, selecting patients of NPH who are likely to benefit from shunt surgery, and to select patients of NPH who are not likely to benefit from shunt surgery.
The Organization of Movement in Slime Mold Plasmodia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, Peter A.
1963-04-22
At first sight, the noncellular slime mold plasmodia appear to be ideal organisms in which to study protoplasmic movement. They are large, easily manipulated, and display high speed protoplasmic streaming. After some experience with them, however, one is likely to become discouraged by the complexity and lability of their movement patterns. While the streaming movements necessarily follow the laws of hydrodynamics, it has not so far been possible to explain them satisfactorily in terms of any simple mechanism. The characteristics of plasmodial streaming which lead to confusion and frustration are outlined below as a substitute for direct observations and cine-photographicmore » records.« less
Real-time myocardium segmentation for the assessment of cardiac function variation
NASA Astrophysics Data System (ADS)
Zoehrer, Fabian; Huellebrand, Markus; Chitiboi, Teodora; Oechtering, Thekla; Sieren, Malte; Frahm, Jens; Hahn, Horst K.; Hennemuth, Anja
2017-03-01
Recent developments in MRI enable the acquisition of image sequences with high spatio-temporal resolution. Cardiac motion can be captured without gating and triggering. Image size and contrast relations differ from conventional cardiac MRI cine sequences requiring new adapted analysis methods. We suggest a novel segmentation approach utilizing contrast invariant polar scanning techniques. It has been tested with 20 datasets of arrhythmia patients. The results do not differ significantly more between automatic and manual segmentations than between observers. This indicates that the presented solution could enable clinical applications of real-time MRI for the examination of arrhythmic cardiac motion in the future.
Aladmawi, Mohamed A.; Vriz, Olga; Galzerano, Domenico
2017-01-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus. PMID:28540078
Digital image analysis of a turbulent flame
NASA Astrophysics Data System (ADS)
Zucherman, L.; Kawall, J. G.; Keffer, J. F.
1988-01-01
Digital image analysis of cine pictures of an unconfined rich premixed turbulent flame has been used to determine structural characteristics of the turbulent/non-turbulent interface of the flame. The results, comprising various moments of the interface position, probability density functions and correlation functions, establish that the instantaneous flame-interface position is essentially a Gaussian random variable with a superimposed quasi-periodical component. The latter is ascribable to a pulsation caused by the convection and the stretching of ring vortices present within the flame. To a first approximation, the flame can be considered similar to a three-dimensional axisymmetric turbulent jet, with superimposed ring vortices, in which combustion occurs.
Health and innovation: economic dynamics and Welfare State in Brazil.
Gadelha, Carlos Augusto Grabois; Braga, Patrícia Seixas da Costa
2016-11-03
The effective enforcement of the access to healthcare as fundamental right requires an important theoretical and political effort at linking the often contradictory economic and social dimensions of development. This study suggests the need for a systemic view of policies related to the industrial base and innovation in health and the construction of the Brazilian Unified National Health System (SUS). The authors investigate the relations between health, innovation, and development, seeking to show and update the political, economic, and social determinants of the recent Brazilian experience with the Health Economic-Industrial Complex (HEIC). They discuss how the agenda for innovation and domestic industrial production in health gained a central place in the project for construction of the SUS. The article thus seeks to link inherent issues from the agenda for development, production, and innovation to social policy in healthcare, as observed in recent years, and based on this analysis, points to political and conceptual challenges for implementing the SUS, especially as regards strengthening its technological and industrial base. As a byproduct, the article develops an analytical and factual focus on the consolidation of the HEIC in Brazil, both as a dynamic vector of industrial development, generating investment, income, employment, and innovations, and as a decisive element for reducing vulnerability and structural dependence in health. The authors aim to show that strengthening the SUS and orienting it to social needs is an essential part of building a social Welfare State in Brazil. Resumo: A efetivação da saúde como um direito fundamental exige importante esforço, teórico e político, de articulação das dimensões econômicas e sociais, por vezes contraditórias, do desenvolvimento. Este trabalho indica a necessidade de um olhar sistêmico das políticas relacionadas à base produtiva e de inovação em saúde e à construção do Sistema Único de Saúde (SUS). Investiga as relações entre saúde, inovação e desenvolvimento, buscando mostrar e atualizar os determinantes políticos, econômicos e sociais da experiência brasileira recente relacionada ao Complexo Econômico-Industrial da Saúde (CEIS). Mostra como a agenda da inovação e da produção nacional em saúde ganhou centralidade no projeto de construção do SUS. O artigo procura, assim, articular questões inerentes à agenda do desenvolvimento, da produção e da inovação com a política social em saúde, tal como observado nos últimos anos e, valendo-se de sua análise, aponta desafios políticos e conceituais para a efetivação do SUS, em especial no que se refere ao fortalecimento de sua base tecnológica e produtiva. Como desdobramento, desenvolve um enfoque analítico e factual que relaciona a consolidação do CEIS no Brasil tanto como um vetor dinâmico do desenvolvimento industrial, gerando investimento, renda, emprego e inovações, quanto como elemento decisivo para a redução da vulnerabilidade e da dependência estrutural em saúde. Procura mostrar que seu fortalecimento e direcionamento para as necessidades sociais é parte essencial da construção de um Estado de Bem-Estar Social no Brasi.
Dynamic deformable models for 3D MRI heart segmentation
NASA Astrophysics Data System (ADS)
Zhukov, Leonid; Bao, Zhaosheng; Gusikov, Igor; Wood, John; Breen, David E.
2002-05-01
Automated or semiautomated segmentation of medical images decreases interstudy variation, observer bias, and postprocessing time as well as providing clincally-relevant quantitative data. In this paper we present a new dynamic deformable modeling approach to 3D segmentation. It utilizes recently developed dynamic remeshing techniques and curvature estimation methods to produce high-quality meshes. The approach has been implemented in an interactive environment that allows a user to specify an initial model and identify key features in the data. These features act as hard constraints that the model must not pass through as it deforms. We have employed the method to perform semi-automatic segmentation of heart structures from cine MRI data.
Sharif, Behzad; Bresler, Yoram
2013-01-01
Patient-Adaptive Reconstruction and Acquisition Dynamic Imaging with Sensitivity Encoding (PARADISE) is a dynamic MR imaging scheme that optimally combines parallel imaging and model-based adaptive acquisition. In this work, we propose the application of PARADISE to real-time cardiac MRI. We introduce a physiologically improved version of a realistic four-dimensional cardiac-torso (NCAT) phantom, which incorporates natural beat-to-beat heart rate and motion variations. Cardiac cine imaging using PARADISE is simulated and its performance is analyzed by virtue of the improved phantom. Results verify the effectiveness of PARADISE for high resolution un-gated real-time cardiac MRI and its superiority over conventional acquisition methods. PMID:24398475
Jurado-Román, Alfonso; Sánchez-Pérez, Ignacio; Lozano Ruíz-Poveda, Fernando; López-Lluva, María T; Pinilla-Echeverri, Natalia; Moreno Arciniegas, Andrea; Agudo-Quilez, Pilar; Gil Agudo, Antonio
2016-01-01
A reduction in radiation doses at the catheterization laboratory, maintaining the quality of procedures is essential. Our objective was to analyze the results of a simple radiation reduction protocol at a high-volume interventional cardiology unit. We analyzed 1160 consecutive procedures: 580 performed before the implementation of the protocol and 580 after it. The protocol consisted in: the reduction of the number of ventriculographies and aortographies, the optimization of the collimation and the geometry of the X ray tube-patient-receptor, the use of low dose-rate fluoroscopy and the reduction of the number of cine sequences using the software "last fluoroscopy hold". There were no significant differences in clinical baseline features or in the procedural characteristics with the exception of a higher percentage of radial approach (30.7% vs 69.6%; p<0.001) and of percutaneous coronary interventions of chronic total occlusions after the implementation of the protocol (2.1% vs 6.7%; p=0,001). Angiographic success was similar during both periods (98.3% vs 99.2%; p=0.2). There were no significant differences between both periods regarding the overall duration of the procedures (26.9 vs 29.6min; p=0.14), or the fluoroscopy time (13.3 vs 13.2min; p=0.8). We observed a reduction in the percentage of procedures with ventriculography (80.9% vs 7.1%; p<0.0001) or aortography (15.4% vs 4.4%; p<0.0001), the cine runs (21.8 vs 6.9; p<0.0001) and the dose-area product (165 vs 71 Gyxcm(2); p<0.0001). With the implementation of a simple radiation reduction protocol, a 57% reduction of dose-area product was observed without a reduction in the quality or the complexity of procedures. Copyright © 2016 Elsevier Inc. All rights reserved.
Mukherjee, Debraj; Pressman, Barry D; Krakow, Deborah; Rimoin, David L; Danielpour, Moise
2014-09-01
Achondroplasia may be associated with compression at the cervicomedullary junction. Determining which patients are at greatest risk for neurological complications of cervicomedullary compression can be difficult. In the current study the authors reviewed their records to determine the incidence and clinical significance of dynamic cervicomedullary stenosis and obstruction of CSF flow along with surgical outcomes following posterior fossa decompression. The authors reviewed 34 consecutive cases involving symptomatic children with achondroplasia undergoing cervicomedullary decompression performed by a single surgeon over 11 years. Of these patients, 29 had undergone preoperative dynamic MRI of the cervicomedullary junction with cine (cinema) CSF flow studies; 13 of these patients underwent postoperative dynamic MRI studies. Clinical outcomes included changes in polysomnography, head circumference percentile, and fontanel characteristics. Radiographic outcomes included changes in dynamic spinal cord diameter, improvement in CSF flow at the foramen magnum, and change in the Evans ratio. Patients were predominantly female, with a mean age at presentation of 6.6 years and mean follow-up of 3.7 years (range 1-10 years). All patients had moderate to excellent improvement in postoperative polysomnography, slight decrease in average head circumference percentile (from 46.9th percentile to 45.7th percentile), and no subjective worsening of fontanel characteristics. The Evans ratio decreased by 2%, spinal cord diameter increased an average of 3.1 mm, 5.2 mm, and 0.2 mm in the neutral, flexed, and extended positions, respectively, and CSF flow improved qualitatively in all 3 positions. There were no postoperative infections, CSF leaks, or other major complications. None of the patients undergoing initial foramen magnum decompression performed at our medical center required reoperation. Patients with achondroplasia and symptomatic cervicomedullary compression have increased risk of dynamic stenosis at the foramen magnum evident upon dynamic cine MRI. Operative decompression may be offered with low risk of complications or need for reoperation.
Prati, Giulio; Vitrella, Giancarlo; Allocca, Giuseppe; Muser, Daniele; Buttignoni, Sonja Cukon; Piccoli, Gianluca; Morocutti, Giorgio; Delise, Pietro; Pinamonti, Bruno; Proclemer, Alessandro; Sinagra, Gianfranco; Nucifora, Gaetano
2015-11-01
Analysis of right ventricular (RV) regional dysfunction by cardiac magnetic resonance (CMR) imaging in arrhythmogenic RV cardiomyopathy (ARVC) may be inadequate because of the complex contraction pattern of the RV. Aim of this study was to determine the use of RV strain and dyssynchrony assessment in ARVC using feature-tracking CMR analysis. Thirty-two consecutive patients with ARVC referred to CMR imaging were included. Thirty-two patients with idiopathic RV outflow tract arrhythmias and 32 control subjects, matched for age and sex to the ARVC group, were included for comparison purpose. CMR imaging was performed to assess biventricular function; feature-tracking analysis was applied to the cine CMR images to assess regional and global longitudinal, circumferential, and radial RV strains and RV dyssynchrony (defined as the SD of the time-to-peak strain of the RV segments). RV global longitudinal strain (-17±5% versus -26±6% versus -29±6%; P<0.001), global circumferential strain (-9±4% versus -12±4% versus -13±5%; P=0.001), and global radial strain (18 [12-26]% versus 22 [15-32]% versus 27 [20-39]%; P=0.015) were significantly lower and SD of the time-to-peak RV strain in all 3 directions were significantly higher among patients with ARVC compared with patients with RV outflow tract arrhythmias and controls. RV global longitudinal strain >-23.2%, SD of the time-to-peak RV longitudinal strain >113.1 ms, and SD of the time-to-peak RV circumferential strain >177.1 ms allowed correct identification of 88%, 75%, and 63% of ARVC patients with no or only minor CMR criteria for ARVC diagnosis. Strain analysis by feature-tracking CMR helps to objectively quantify global and regional RV dysfunction and RV dyssynchrony in patients with ARVC and provides incremental value over conventional cine CMR imaging. © 2015 American Heart Association, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuangrod, T; Simpson, J; Greer, P
Purpose: A real-time patient treatment delivery verification system using EPID (Watchdog) has been developed as an advanced patient safety tool. In a pilot study data was acquired for 119 prostate and head and neck (HN) IMRT patient deliveries to generate body-site specific action limits using statistical process control. The purpose of this study is to determine the sensitivity of Watchdog to detect clinically significant errors during treatment delivery. Methods: Watchdog utilizes a physics-based model to generate a series of predicted transit cine EPID images as a reference data set, and compares these in real-time to measured transit cine-EPID images acquiredmore » during treatment using chi comparison (4%, 4mm criteria) after the initial 2s of treatment to allow for dose ramp-up. Four study cases were used; dosimetric (monitor unit) errors in prostate (7 fields) and HN (9 fields) IMRT treatments of (5%, 7%, 10%) and positioning (systematic displacement) errors in the same treatments of (5mm, 7mm, 10mm). These errors were introduced by modifying the patient CT scan and re-calculating the predicted EPID data set. The error embedded predicted EPID data sets were compared to the measured EPID data acquired during patient treatment. The treatment delivery percentage (measured from 2s) where Watchdog detected the error was determined. Results: Watchdog detected all simulated errors for all fields during delivery. The dosimetric errors were detected at average treatment delivery percentage of (4%, 0%, 0%) and (7%, 0%, 0%) for prostate and HN respectively. For patient positional errors, the average treatment delivery percentage was (52%, 43%, 25%) and (39%, 16%, 6%). Conclusion: These results suggest that Watchdog can detect significant dosimetric and positioning errors in prostate and HN IMRT treatments in real-time allowing for treatment interruption. Displacements of the patient require longer to detect however incorrect body site or very large geographic misses will be detected rapidly.« less
Greffier, J; Van Ngoc Ty, C; Bonniaud, G; Moliner, G; Ledermann, B; Schmutz, L; Cornillet, L; Cayla, G; Beregi, J P; Pereira, F
2017-06-01
To compare the use of a dose mapping software to Gafchromic film measurement for a simplified peak skin dose (PSD) estimation in interventional cardiology procedure. The study was conducted on a total of 40 cardiac procedures (20 complex coronary angioplasty of chronic total occlusion (CTO) and 20 coronary angiography and coronary angioplasty (CA-PTCA)) conducted between January 2014 to December 2015. PSD measurement (PSD Film ) was obtained by placing XR-RV3 Gafchromic under the patient's back for each procedure. PSD (PSD em.dose ) was computed with the software em.dose©. The calculation was performed on the dose metrics collected from the private dose report of each procedure. Two calculation methods (method A: fluoroscopic kerma equally spread on cine acquisition and B: fluoroscopic kerma is added to one air Kerma cine acquisition that contributes to the PSD) were used to calculate the fluoroscopic dose contribution as fluoroscopic data were not recorded in our interventional room. Statistical analyses were carried out to compare PSD Film and PSD em.dose . The PSD Film median (1st quartile; 3rd quartile) was 0.251(0.190;0.336)Gy for CA-PTCA and 1.453(0.767;2.011)Gy for CTO. For method-A, the PSD em.dose was 0.248(0.182;0.369)Gy for CA-PTCA and 1.601(0.892;2.178)Gy for CTO, and 0.267(0.223;0.446)Gy and 1.75 (0.912;2.584)Gy for method-B, respectively. For the two methods, the correlation between PSD Film and PSD em.dose was strong. For all cardiology procedures investigated, the mean deviation between PSD Film and PSD em.dose was 3.4±21.1% for method-A and 17.3%±23.9% for method-B. The dose mapping software is convenient to calculate peak skin dose in interventional cardiology. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Sensor-Based Electromagnetic Navigation (Mediguide®): How Accurate Is It? A Phantom Model Study.
Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Grebmer, Christian; Telishevska, Marta; Brkic, Amir; Semmler, Verena; Lennerz, Carsten; Kaess, Bernhard; Kottmaier, Marc; Kolb, Christof; Deisenhofer, Isabel; Hessling, Gabriele
2015-10-01
Data about localization reproducibility as well as spatial and visual accuracy of the new MediGuide® sensor-based electroanatomic navigation technology are scarce. We therefore sought to quantify these parameters based on phantom experiments. A realistic heart phantom was generated in a 3D-Printer. A CT scan was performed on the phantom. The phantom itself served as ground-truth reference to ensure exact and reproducible catheter placement. A MediGuide® catheter was repeatedly tagged at selected positions to assess accuracy of point localization. The catheter was also used to acquire a MediGuide®-scaled geometry in the EnSite Velocity® electroanatomic mapping system. The acquired geometries (MediGuide®-scaled and EnSite Velocity®-scaled) were compared to a CT segmentation of the phantom to quantify concordance. Distances between landmarks were measured in the EnSite Velocity®- and MediGuide®-scaled geometry and the CT dataset for Bland-Altman comparison. The visualization of virtual MediGuide® catheter tips was compared to their corresponding representation on fluoroscopic cine-loops. Point localization accuracy was 0.5 ± 0.3 mm for MediGuide® and 1.4 ± 0.7 mm for EnSite Velocity®. The 3D accuracy of the geometries was 1.1 ± 1.4 mm (MediGuide®-scaled) and 3.2 ± 1.6 mm (not MediGuide®-scaled). The offset between virtual MediGuide® catheter visualization and catheter representation on corresponding fluoroscopic cine-loops was 0.4 ± 0.1 mm. The MediGuide® system shows a very high level of accuracy regarding localization reproducibility as well as spatial and visual accuracy, which can be ascribed to the magnetic field localization technology. The observed offsets between the geometry visualization and the real phantom are below a clinically relevant threshold. © 2015 Wiley Periodicals, Inc.
High performance MRI simulations of motion on multi-GPU systems.
Xanthis, Christos G; Venetis, Ioannis E; Aletras, Anthony H
2014-07-04
MRI physics simulators have been developed in the past for optimizing imaging protocols and for training purposes. However, these simulators have only addressed motion within a limited scope. The purpose of this study was the incorporation of realistic motion, such as cardiac motion, respiratory motion and flow, within MRI simulations in a high performance multi-GPU environment. Three different motion models were introduced in the Magnetic Resonance Imaging SIMULator (MRISIMUL) of this study: cardiac motion, respiratory motion and flow. Simulation of a simple Gradient Echo pulse sequence and a CINE pulse sequence on the corresponding anatomical model was performed. Myocardial tagging was also investigated. In pulse sequence design, software crushers were introduced to accommodate the long execution times in order to avoid spurious echoes formation. The displacement of the anatomical model isochromats was calculated within the Graphics Processing Unit (GPU) kernel for every timestep of the pulse sequence. Experiments that would allow simulation of custom anatomical and motion models were also performed. Last, simulations of motion with MRISIMUL on single-node and multi-node multi-GPU systems were examined. Gradient Echo and CINE images of the three motion models were produced and motion-related artifacts were demonstrated. The temporal evolution of the contractility of the heart was presented through the application of myocardial tagging. Better simulation performance and image quality were presented through the introduction of software crushers without the need to further increase the computational load and GPU resources. Last, MRISIMUL demonstrated an almost linear scalable performance with the increasing number of available GPU cards, in both single-node and multi-node multi-GPU computer systems. MRISIMUL is the first MR physics simulator to have implemented motion with a 3D large computational load on a single computer multi-GPU configuration. The incorporation of realistic motion models, such as cardiac motion, respiratory motion and flow may benefit the design and optimization of existing or new MR pulse sequences, protocols and algorithms, which examine motion related MR applications.
SU-F-J-115: Target Volume and Artifact Evaluation of a New Device-Less 4D CT Algorithm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, R; Pan, T
2016-06-15
Purpose: 4DCT is often used in radiation therapy treatment planning to define the extent of motion of the visible tumor (IGTV). Recent available software allows 4DCT images to be created without the use of an external motion surrogate. This study aims to compare this device-less algorithm to a standard device-driven technique (RPM) in regards to artifacts and the creation of treatment volumes. Methods: 34 lung cancer patients who had previously received a cine 4DCT scan on a GE scanner with an RPM determined respiratory signal were selected. Cine images were sorted into 10 phases based on both the RPM signalmore » and the device-less algorithm. Contours were created on standard and device-less maximum intensity projection (MIP) images using a region growing algorithm and manual adjustment to remove other structures. Variations in measurements due to intra-observer differences in contouring were assessed by repeating a subset of 6 patients 2 additional times. Artifacts in each phase image were assessed using normalized cross correlation at each bed position transition. A score between +1 (artifacts “better” in all phases for device-less) and −1 (RPM similarly better) was assigned for each patient based on these results. Results: Device-less IGTV contours were 2.1 ± 1.0% smaller than standard IGTV contours (not significant, p = 0.15). The Dice similarity coefficient (DSC) was 0.950 ± 0.006 indicating good similarity between the contours. Intra-observer variation resulted in standard deviations of 1.2 percentage points in percent volume difference and 0.005 in DSC measurements. Only two patients had improved artifacts with RPM, and the average artifact score (0.40) was significantly greater than zero. Conclusion: Device-less 4DCT can be used in place of the standard method for target definition due to no observed difference between standard and device-less IGTVs. Phase image artifacts were significantly reduced with the device-less method.« less
Sahul, Zakir H.; Mukherjee, Rupak; Song, James; McAteer, Jarod; Stroud, Robert E.; Dione, Donald P.; Staib, Lawrence; Papademetris, Xenophon; Dobrucki, Lawrence W.; Duncan, James S.; Spinale, Francis G.; Sinusas, Albert J.
2011-01-01
Background Matrix metalloproteinases (MMPs) are known to modulate left ventricular (LV) remodeling after a myocardial infarction (MI). However, the temporal and spatial variation of MMP activation and their relationship to mechanical dysfunction post MI remains undefined. Methods and Results MI was surgically induced in pigs (n=23) and cine MR and dual isotope hybrid SPECT/CT imaging obtained using thallium-201 (201Tl) and a technetium-99m labeled MMP targeted tracer (99mTc-RP805) at 1, 2 and 4 weeks post MI along with controls (n=5). Regional myocardial strain was computed from MR images and related to MMP zymography and ex vivo myocardial 99mTc-RP805 retention. MMP activation as assessed by in vivo and ex vivo 99mTc-RP805 imaging/retention studies was increased nearly 5-fold within the infarct region at 1 week post-MI and remained elevated up to 1 month post-MI. The post-MI change in LV end-diastolic volumes was correlated with MMP activity (y=31.34e0.48x, p=0.04). MMP activity was increased within the border and remote regions early post-MI, but declined over 1 month. There was a high concordance between regional 99mTc-RP805 uptake and ex vivo MMP-2 activity. Conclusions A novel, multimodality non-invasive hybrid SPECT/CT imaging approach was validated and applied for in vivo evaluation of MMP activation in combination with cine MR analysis of LV deformation. Increased 99mTc-RP805 retention was seen throughout the heart early post-MI and was not purely a reciprocal of 201Tl perfusion. 99mTc-RP805 SPECT/CT imaging may provide unique information regarding regional myocardial MMP activation and predict late post-MI LV remodeling. PMID:21505092
Sievers, Burkhard; Schrader, Sebastian; Rehwald, Wolfgang; Hunold, Peter; Barkhausen, Joerg; Erbel, Raimund
2011-06-01
Papillary muscles and trabeculae for ventricular function analysis are known to significantly contribute to accurate volume and mass measurements. Fast imaging techniques such as three-dimensional steady-state free precession (3D SSFP) are increasingly being used to speed up imaging time, but sacrifice spatial resolution. It is unknown whether 3D SSFP, despite its reduced spatial resolution, allows for exact delineation of papillary muscles and trabeculations. We therefore compared 3D SSFP ventricular function measurements to those measured from standard multi-breath hold two-dimensional steady-state free precession cine images (standard 2D SSFP). 14 healthy subjects and 14 patients with impaired left ventricularfunction underwent 1.5 Tesla cine imaging. A stack of short axis images covering the left ventricle was acquired with 2D SSFP and 3D SSFP. Left ventricular volumes, ejection fraction, and mass were determined. Analysis was performed by substracting papillary muscles and trabeculae from left ventricular volumes. In addition, reproducibility was assessed. EDV, ESV, EF, and mass were not significantly different between 2D SSFP and 3D SSFP (mean difference healthy subjects: -0.06 +/- 3.2 ml, 0.54 +/- 2.2 ml, -0.45 +/- 1.8%, and 1.13 +/- 0.8 g, respectively; patients: 1.36 +/- 2.8 ml, -0.15 3.5 ml, 0.86 +/- 2.5%, and 0.91 +/- 0.9 g, respectively; P > or = 0.095). Intra- and interobserver variability was not different for 2D SSFP (P > or = 0.64 and P > or = 0.397) and 3D SSFP (P > or = 0.53 and P > or = 0.47). Differences in volumes, EF, and mass measurements between 3D SSFP and standard 2D SSFP are very small, and not statistically significant. 3D SSFP may be used for accurate ventricular function assessment when papillary muscles and trabeculations are to be taken into account.
Lin, Kai; Collins, Jeremy D; Chowdhary, Varun; Markl, Michael; Carr, James C
2016-10-01
To test the performance of HDA in characterizing left ventricular (LV) function and regional myocardial motion patterns in the context of cardiomyopathy based on cine cardiovascular magnetic resonance (CMR). Following the approval of the institutional review board (IRB), standard cine images of 45 subjects, including 15 healthy volunteers, 15 patients with hypertrophic cardiomyopathy (HCM) and 15 patients with dilated cardiomyopathy (DCM) were retrospectively analyzed using HDA. The variations of LV ejection fraction (LVEF), LV mass (LVM), and regional myocardial motion indices, including radial (Drr), circumferential (Dcc) displacement, radial (Vrr) and circumferential (Vcc) velocity, radial (Err), circumferential (Ecc) and shear (Ess) strain and radial (SRr) and circumferential (SRc) strain rate, were calculated and compared among subject groups. Inter-study reproducibility of HDA-derived myocardial motion indices were tested on 15 volunteers by using intra-class correlation coefficient (ICC) and coefficient of variation (CoV). HDA identified significant differences in cardiac function and motion indices between subject groups. DCM patients had significantly lower LVEF (33.5±9.65%), LVM (105.88±21.93g), peak Drr (0.29±0.11cm), Vrr-sys (2.14±0.72cm/s), Err (0.17±0.08), Ecc (-0.08±0.03), SRr-sys (0.91±0.44s(-1)) and SRc-sys (-0.64±0.27s(-1)) compared to the other two groups. HCM patients demonstrated increased LVM (171.69±34.19) and lower peak Vcc-dia (0.78±0.30cm/s) than other subjects. Good inter-study reproducibility was found for all HDA-derived myocardial indices in healthy volunteers (ICC=0.664-0.942, CoV=15.1%-37.1%). Without the need for operator interaction, HDA is a reproducible method for the automated characterization of global and regional LV function in the context of cardiomyopathy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Maddison, R. J.
1985-02-01
The investigation of certain areas of nuclear reactor safety involves the study of high speed phenomena with timescales ranging from microseconds to a few hundreds of milliseconds. Examples which have been extensively studied at Winfrith are firstly, the thermal interaction of molten fuel and reactor coolant which can generate high pressures on the 100 msec timescale, and which involves phenomena such as vapour film collapse which takes place on the microsecond timescale. Secondly, there is the response of reactor structures to such pressures, and finally there is the response of structural materials such as metals and concrete to the impulsive loading arising from the impact of heavy, high velocity missiles. A wide range of experimental techniques is used in these studies, many of which have been developed specially for this type of work which ranges from small laboratory scale to large field scale experiments. There are two important features which characterise many of these experiments:- i) a long period of meticulous preparation of very heavily instrumented, short duration experiments and; ii) the destructive nature of the experiments. Various forms of High Speed photography are included in the inventory of experimental techniques. These include the use of single and double exposure, short duration, spark photography; the use of an Image Convertor Camera (IMACON 790); and a number of rotating prism cine cameras. High Speed Photography is used both in a primary experimental role in the studies, and in a supportive role for other instrumentation. Because of the sometimes violent nature of these experiments, cameras are often heavily protected and operated remotely; lighting systems are sometimes destroyed. This has led to the development of unconventional techniques for camera operation and subject lighting. This paper will describe some of the experiments and the way in which High Speed Photography has been applied as an essential experimental tool. It will be illustrated with cine film taken during the experiments.
SU-E-J-158: Audiovisual Biofeedback Reduces Image Artefacts in 4DCT: A Digital Phantom Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pollock, S; Kipritidis, J; Lee, D
2015-06-15
Purpose: Irregular breathing motion has a deleterious impact on 4DCT image quality. The breathing guidance system: audiovisual biofeedback (AVB) is designed to improve breathing regularity, however, its impact on 4DCT image quality has yet to be quantified. The purpose of this study was to quantify the impact of AVB on thoracic 4DCT image quality by utilizing the digital eXtended Cardiac Torso (XCAT) phantom driven by lung tumor motion patterns. Methods: 2D tumor motion obtained from 4 lung cancer patients under two breathing conditions (i) without breathing guidance (free breathing), and (ii) with guidance (AVB). There were two breathing sessions, yieldingmore » 8 tumor motion traces. This tumor motion was synchronized with the XCAT phantom to simulate 4DCT acquisitions under two acquisition modes: (1) cine mode, and (2) prospective respiratory-gated mode. Motion regularity was quantified by the root mean square error (RMSE) of displacement. The number of artefacts was visually assessed for each 4DCT and summed up for each breathing condition. Inter-session anatomic reproducibility was quantified by the mean absolute difference (MAD) between the Session 1 4DCT and Session 2 4DCT. Results: AVB improved tumor motion regularity by 30%. In cine mode, the number of artefacts was reduced from 61 in free breathing to 40 with AVB, in addition to AVB reducing the MAD by 34%. In gated mode, the number of artefacts was reduced from 63 in free breathing to 51 with AVB, in addition to AVB reducing the MAD by 23%. Conclusion: This was the first study to compare the impact of breathing guidance on 4DCT image quality compared to free breathing, with AVB reducing the amount of artefacts present in 4DCT images in addition to improving inter-session anatomic reproducibility. Results thus far suggest that breathing guidance interventions could have implications for improving radiotherapy treatment planning and interfraction reproducibility.« less
[A photo-optical observation of gallbladder motility in dogs (author's transl)].
Kudo, N
1976-03-01
A photo-optical observation on gallbladder motility was made with the 16 mm cine-cholangiography. The subjects studied were thirty two mongrel dogs. The gallbladder was exposed by a short upper midline abdominal incision under pentothal anesthesia. Gallbladder bile was aspirated and contrast medium was given into the bladder, through a transhepatic route. The cine-cholangiography was done by an image intensifier at a speed of one frame every 2 to 4 seconds. The cinefilms taken were observed repeatedly by the screen projection at various speeds. The drawings were made by tracing the outline of the image of the gallbladder on each frame and were overlapped. Moreover, a contraction curve was made by the cholecystometry using of film motion analyzer in every case. At the same time bile flow into the duodenum was recorded to study a relationship between the gallbladder contraction and motility of the terminal common bile duct. The results obtained are as follows: 1. In a resting state any contraction of the gallbladder was not seen during 30 minutes, and a peristalsis-like movements of the neck portion was observed. However, there was not a relationship between the contraction curve of the gallbladder and the bile flow into the duodenum. 2. Immediately after giving Caerulein, the contrast medium injected into the gallbladder was rapidly discharged into the common bile duct by a peristalsis-like movement of the neck. The size of the gallbladder was markedly decreased into three fifths of the initial state three minutes after administration. At the same time contrast medium was continuously discharged into the duodenum. 3. After giving pilocarpine a marked contraction with forceful movement of the neck and body was observed, and the size of the gallbladder was decreased into three quarters ot the initial state. Bile discharge into the duodenum was markedly increased with an active open- and closing movement of the terminal common bile duct.
Zhang, Xiaoyan; Liu, Zhan-Qiu; Singh, Dara; Wehner, Gregory J; Powell, David K; Campbell, Kenneth S; Fornwalt, Brandon K; Wenk, Jonathan F
2017-08-01
Rat models have assumed an increasingly important role in cardiac research. However, a detailed profile of regional cardiac mechanics, such as strains and torsion, is lacking for rats. We hypothesized that healthy rat left ventricles (LVs) exhibit regional differences in cardiac mechanics, which are part of normal function. In this study, images of the LV were obtained with 3D cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance in 10 healthy rats. To evaluate regional cardiac mechanics, the LV was divided into basal, mid-ventricular, and apical regions. The myocardium at the mid-LV was further partitioned into four wall segments (i.e. septal, inferior, lateral, and anterior) and three transmural layers (i.e. sub-endocardium, mid-myocardium, and sub-epicardium). The six Lagrangian strain components (i.e. E rr , E cc , E ll , E cl , E rl , and E cr ) were computed from the 3D displacement field and averaged within each region of interest. Torsion was quantified using the circumferential-longitudinal shear angle. While peak systolic E cl differed between the mid-ventricle and apex, the other five components of peak systolic strain were similar across the base, mid-ventricle, and apex. In the mid-LV myocardium, E cc decreased gradually from the sub-endocardial to the sub-epicardial layer. E ll demonstrated significant differences between the four wall segments, with the largest magnitude in the inferior segment. E rr was uniform among the four wall segments. E cl varied along the transmural direction and among wall segments, whereas E rl differed only among the wall segments. E rc was not associated with significant variations. Torsion also varied along the transmural direction and among wall segments. These results provide fundamental insights into the regional contractile function of healthy rat hearts, and form the foundation for future studies on regional changes induced by disease or treatments. Copyright © 2017 John Wiley & Sons, Ltd.
Mori, Shinichiro; Chen, George T Y; Endo, Masahiro
2007-09-01
To analyze the water equivalent pathlength (WEL) fluctuations resulting from cardiac motion and display these variations on a beam's-eye-view image; the analysis provides insight into the accuracy of lung tumor irradiation with heavy charged particle beams. Volumetric cine computed tomography (CT) images were obtained on 7 lung cancer patients under free-breathing conditions with a 256-multislice CT scanner. Cardiac phase was determined by selecting systole and diastole. A WEL difference image (DeltaWEL) was calculated by subtracting the WEL image at end-systole from that at end-diastole at respiratory exhalation phase. Two calculation regions were defined: Region 1 was limited to the volume defined by planes bounding the heart; Region 2 included the entire body thickness for a given beam's-eye-view angle. The DeltaWEL values observed in Region 1 showed fluctuations at the periphery of the heart that varied from 20.4 (SD, 5.2) mm WEL to -15.6 (3.2) mm WEL. The areas over which these range perturbation values were observed were 36.8 (32.4) mm(2) and 6.0 (2.8) mm(2) for positive and negative WEL, respectively. The WEL fluctuations in Region 2 increased by approximately 3-4 mm WEL, whereas negative WEL fluctuations changed by approximately -4 to -5 mm WEL, compared with WEL for Region 1; areas over 20 mm WEL changes in Region 2 increased by 9 mm(2) for positive DeltaWEL and 2 mm(2) for negative DeltaWEL. Cine CT with a 256-multislice CT scanner captures both volumetric cardiac and respiratory motion with a temporal resolution sufficient to estimate range fluctuations by these motions. This information can be used to assess the range perturbations that charged particle beams may experience in irradiation of lung or esophageal tumors adjacent to the heart.
NASA Astrophysics Data System (ADS)
Reed, Judd E.; Rumberger, John A.; Buithieu, Jean; Behrenbeck, Thomas; Breen, Jerome F.; Sheedy, Patrick F., II
1995-05-01
Electron beam computed tomography is unparalleled in its ability to consistently produce high quality dynamic images of the human heart. Its use in quantification of left ventricular dynamics is well established in both clinical and research applications. However, the image analysis tools supplied with the scanners offer a limited number of analysis options. They are based on embedded computer systems which have not been significantly upgraded since the scanner was introduced over a decade ago in spite of the explosive improvements in available computer power which have occured during this period. To address these shortcomings, a workstation-based ventricular analysis system has been developed at our institution. This system, which has been in use for over five years, is based on current workstation technology and therefore has benefited from the periodic upgrades in processor performance available to these systems. The dynamic image segmentation component of this system is an interactively supervised, semi-automatic surface identification and tracking system. It characterizes the endocardial and epicardial surfaces of the left ventricle as two concentric 4D hyper-space polyhedrons. Each of these polyhedrons have nearly ten thousand vertices which are deposited into a relational database. The right ventricle is also processed in a similar manner. This database is queried by other custom components which extract ventricular function parameters such as regional ejection fraction and wall stress. The interactive tool which supervises dynamic image segmentation has been enhanced with a temporal domain display. The operator interactively chooses the spatial location of the endpoints of a line segment while the corresponding space/time image is displayed. These images, with content resembling M-Mode echocardiography, benefit form electron beam computed tomography's high spatial and contrast resolution. The segmented surfaces are displayed along with the imagery. These displays give the operator valuable feedback pertaining to the contiguity of the extracted surfaces. As with M-Mode echocardiography, the velocity of moving structures can be easily visualized and measured. However, many views inaccessible to standard transthoracic echocardiography are easily generated. These features have augmented the interpretability of cine electron beam computed tomography and have prompted the recent cloning of this system into an 'omni-directional M-Mode display' system for use in digital post-processing of echocardiographic parasternal short axis tomograms. This enhances the functional assessment in orthogonal views of the left ventricle, accounting for shape changes particularly in the asymmetric post-infarction ventricle. Conclusions: A new tool has been developed for analysis and visualization of cine electron beam computed tomography. It has been found to be very useful in verifying the consistency of myocardial surface definition with a semi-automated segmentation tool. By drawing on M-Mode echocardiography experience, electron beam tomography's interpretability has been enhanced. Use of this feature, in conjunction with the existing image processing tools, will enhance the presentations of data on regional systolic and diastolic functions to clinicians in a format that is familiar to most cardiologists. Additionally, this tool reinforces the advantages of electron beam tomography as a single imaging modality for the assessment of left and right ventricular size, shape, and regional functions.
Wang, Yingsong; Xie, Jingming; Zhao, Zhi; Zhang, Ying; Li, Tao; Si, Yongyu
2013-05-01
Phase contrast-cine MRI (PC-cine MRI) studies in patients with syringomyelia and Chiari malformation Type I (CM-I) have demonstrated abnormal CSF flow across the foramen magnum, which can revert to normal after craniocervical decompression with syrinx shrinkage. In order to investigate the mechanisms leading to postoperative syringomyelia shrinkage, the authors studied the hydrodynamic changes of CSF flow in the craniocervical junction and spinal canal in patients with scoliosis associated with syringomyelia after one-stage deformity correction by posterior vertebral column resection. Preoperative and postoperative CSF flow dynamics at the levels of the foramen magnum, C-7, T-7 (or apex), and L-1 were assessed by electrocardiogram-synchronized cardiac-gated PC-cine MRI in 8 adolescent patients suffering from severe scoliosis with syringomyelia and CM-I (scoliosis group) and undergoing posterior vertebral column resection. An additional 8 patients with syringomyelia and CM-I without spinal deformity (syrinx group) and 8 healthy volunteers (control group) were also enrolled. Mean values were obtained for the following parameters: the duration of a CSF cycle, the duration of caudad CSF flow (CSF downflow [DF]) and cephalad CSF flow (CSF upflow [UF]), the ratio of DF duration to CSF cycle duration (DF%), and the ratio of UF duration to CSF cycle duration (UF%). The ratio of the stationary phase (SP) duration to CSF cycle duration was calculated (SP%). The maximum downflow velocities (VD max) and maximum upflow velocities (VU max) were measured. SPSS (version 14.0) was used for all statistical analysis. Patients in the scoliosis group underwent one-stage posterior vertebral column resection for deformity correction without suboccipital decompression. The mean preoperative coronal Cobb angle was 102.4° (range 76°-138°). The mean postoperative Cobb angle was 41.7° (range 12°-75°), with an average correction rate of 59.3%. During the follow-up, 1 patient with hypermyotonia experienced a significant decrease of muscle tension and 1 patient with reduced anal sphincter tone manifested recovery. A total of 5 patients demonstrated a significant decrease (> 30%) in syrinx size. With respect to changes in CSF flow dynamics, the syrinx group was characterized by slower and shorter downflow than the control group, and the difference was more significant at the foramen magnum and C-7 levels. In patients with scoliosis, CSF downflow at the foramen magnum level was significantly restricted, and a prolonged stationary phase indicated increased obstruction of CSF flow. After posterior vertebral column resection, the peak velocity of CSF flow at the foramen magnum increased, and the downflow phase duration was markedly prolonged. The parameters showed a return to almost normal CSF dynamics at the craniocervical region, and this improvement was maintained for 6-12 months of follow-up. There were distinct abnormalities of CSF flow at the craniocervical junction in patients with syringomyelia. Abnormal dynamics of downflow could be aggravated by associated severe spinal deformity and improved by correction via posterior vertebral column resection.
[Investigation surrounding a fatal case of yellow fever in Côte d'Ivoire in 1999].
Akoua-Koffi, C; Diarrassouba, S; Bénié, V B; Ngbichi, J M; Bozoua, T; Bosson, A; Akran, V; Carnevale, P; Ehouman, A
2001-08-01
Côte d'Ivoire is an endemic country for yellow fever, but no case was officially notified in recent years. In July 1999, however, one fatal case was reported. A German citizen was infected in the national park of Comoe, in the north eastern area of the country. In order to evaluate the extent of amaril virus circulation and the risk for local people, a virological, entomological and epidemiological investigation was carried out by the ministry of health, the OCCGE, the Côte d'Ivoire Pasteur Institute (IPCI) and the World Health Organisation in the area where the fatal case had been staying. 18 suspected and 24 confirmed mosquito catchers were identified by interview and a blood specimen was collected from each of them. In addition, 159 batches of mosquitoes from which 94 batches of potential vectors were collected; among the suspected cases, 22% were immunised against yellow fever. Serological and virological analyses were made at IPCI and the Paris Pasteur Institute by ELISA technique and isolation on cells cultures and newborn mice. All the suspicious sera and 87.5% of the catchers were positive for IgG anti-amaril virus. One catcher's serum was positive for IgM anti-amaril virus. 11 suspected sera were positive for IgG anti-dengue virus with 1 positive for IgM. 1 strain of amaril virus and 3 strains of Zika virus were isolated from mosquitoes at IPCI and confirmed by CRORA in Dakar. These results indicated that there is a yellow fever and dengue virus are prevalent among the human and vector populations in the study area. Preventive measures must be adopted to protect human beings at risk for amaril infection.
Thunderstorm observations from Space Shuttle
NASA Technical Reports Server (NTRS)
Vonnegut, B.; Vaughan, O. H., Jr.; Brook, M.
1983-01-01
Results of the Nighttime/Daytime Optical Survey of Lightning (NOSL) experiments done on the STS-2 and STS-4 flights are covered. During these two flights of the Space Shuttle Columbia, the astronaut teams of J. Engle and R. Truly, and K. Mattingly II and H. Hartsfield took motion pictures of thunderstorms with a 16 mm cine camera. Film taken during daylight showed interesting thunderstorm cloud formations, where individual frames taken tens of seconds apart, when viewed as stereo pairs, provided information on the three-dimensional structure of the cloud systems. Film taken at night showed clouds illuminated by lightning with discharges that propagated horizontally at speeds of up to 10 to the 5th m/sec and extended for distances on the order of 60 km or more.
High resolution in galaxy photometry and imaging
NASA Astrophysics Data System (ADS)
Nieto, J.-L.; Lelievre, G.
Techniques for increasing the resolution of ground-based photometric observations of galaxies are discussed. The theoretical limitations on resolution and their implications for choosing telescope size at a given site considered, with an emphasis on the importance of the Fried (1966) parameter r0. The techniques recommended are shortening exposure time, selection of the highest-resolution images, and a posteriori digital image processing (as opposed to active-mirror image stabilization or the cine-CCD system of Fort et al., 1984). The value of the increased resolution (by a factor of 2) achieved at Pic du Midi observatory for studies of detailed structure in extragalactic objects, for determining the distance to galaxies, and for probing the central cores of galaxies is indicated.
Risk stratification for therapeutic management and prognosis.
Coelho-Filho, Otavio R; Nallamshetty, Leelakrishna; Kwong, Raymond Y
2009-07-01
In coronary artery disease (CAD), cardiac magnetic resonance (CMR) imaging can integrate several types of pulse-sequence examinations (eg, myocardial perfusion, cine wall motion, T2-weighted imaging for myocardial edema, late gadolinium enhancement, and CMR angiography) that can provide anatomic, functional, and physiologic information about the heart in a single imaging session. Because of this ability to interrogate myocardial physiology using different pulse sequence techniques within a single CMR session, this technique has been recognized increasingly in many centers as the test of choice for assessing patients who present with cardiomyopathy of undetermined cause. This article first reviews the current evidence supporting the prognosticating role of CMR in assessing CAD and then discusses CMR applications and prognostication in many non-coronary cardiac conditions.
The occult submucous cleft palate.
Kaplan, E N
1975-10-01
We have studied 41 patients with classic submucous cleft and 32 cases with occult submucous cleft. Both groups have the same anatomic abnormality that leads to velar dysfunction-the insertion of the palate muscles onto the hard palate rather than onto the midline soft palate raphe. However, the occult submucous cleft palate does not have the classic triad of bifid uvula, hard palate bony notch, and furrow in the midline of the soft palate. Characteristic facial features, cephalmetric x-rays, and cine voice studies can help make a presumptive diagnosis of occult submucous cleft palate. Surgical management includes a diagnostic palate exploration to identify muscle configuration followed by levator muscle sling reconstruction, palate pushback, and pharyngeal flap. Excellent speech results are obtained except with patients having palate paresis.
Development of nonhuman adenoviruses as vaccine vectors
Bangari, Dinesh S.; Mittal, Suresh K.
2006-01-01
Human adenoviral (HAd) vectors have demonstrated great potential as vaccine vectors. Preclinical and clinical studies have demonstrated the feasibility of vector design, robust antigen expression and protective immunity using this system. However, clinical use of adenoviral vectors for vaccine purposes is anticipated to be limited by vector immunity that is either preexisting or develops rapidly following the first inoculation with adenoviral vectors. Vector immunity inactivates the vector particles and rapidly removes the transduced cells, thereby limiting the duration of transgene expression. Due to strong vector immunity, subsequent use of the same vector is usually less efficient. In order to circumvent this limitation, nonhuman adenoviral vectors have been proposed as alternative vectors. In addition to eluding HAd immunity, these vectors possess most of the attractive features of HAd vectors. Several replication-competent or replication-defective nonhuman adenoviral vectors have been developed and investigated for their potential as vaccine delivery vectors. Here, we review recent advances in the design and characterization of various nonhuman adenoviral vectors, and discuss their potential applications for human and animal vaccination. PMID:16297508
Phased array ghost elimination (PAGE) for segmented SSFP imaging with interrupted steady-state.
Kellman, Peter; Guttman, Michael A; Herzka, Daniel A; McVeigh, Elliot R
2002-12-01
Steady-state free precession (SSFP) has recently proven to be valuable for cardiac imaging due to its high signal-to-noise ratio and blood-myocardium contrast. Data acquired using ECG-triggered, segmented sequences during the approach to steady-state, or return to steady-state after interruption, may have ghost artifacts due to periodic k-space distortion. Schemes involving several preparatory RF pulses have been proposed to restore steady-state, but these consume imaging time during early systole. Alternatively, the phased-array ghost elimination (PAGE) method may be used to remove ghost artifacts from the first several frames. PAGE was demonstrated for cardiac cine SSFP imaging with interrupted steady-state using a simple alpha/2 magnetization preparation and storage scheme and a spatial tagging preparation.
Characteristics of sprinklers and water spray mists for fire safety
NASA Astrophysics Data System (ADS)
Jackman, Louise A.; Lavelle, Stephen P.; Nolan, P. F.
1991-04-01
In order to predict the type of sprinkler or spray head required for fire safety in buildings and transport systems (e.g. aircraft) it is necessary to model the interaction of water droplets with the thermally buoyant fire gases. Such modelling requires a detailed knowledge of the mean droplet size, the droplet size distribution, droplet velocity and trajectory. Many existing systems for the characterisation of droplets are indirect in that an optical property is measured and the results are subject to "black box" data processing. A direct method can be developed using a synchronised metal vapour laser and high speed cine camera with appropriate optics. Results on both sprinkler and spray mist will be presented and a basis for the choice of active fire protection systems will be outlined.
FROM THE HISTORY OF PHYSICS: Georgii L'vovich Shnirman: designer of fast-response instruments
NASA Astrophysics Data System (ADS)
Bashilov, I. P.
1994-07-01
A biography is given of the outstanding Russian scientist Georgii L'vovich Shnirman, whose scientific life had been 'top secret'. He was an experimental physicist and instrument designer, the founder of many branches of the Soviet instrument-making industry, the originator of a theory of electric methods of integration and differentiation, a theory of astasisation of pendulums, and also of original measurement methods. He was the originator and designer of automatic systems for the control of the measuring apparatus used at nuclear test sites and of automatic seismic station systems employed in monitoring nuclear tests. He also designed the first loop oscilloscopes in the Soviet Union, high-speed photographic and cine cameras (streak cameras, etc.), and many other unique instruments, including some mounted on moving objects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCowan, P. M., E-mail: pmccowan@cancercare.mb.ca; McCurdy, B. M. C.; Medical Physics Department, CancerCare Manitoba, 675 McDermot Avenue, Winnipeg, Manitoba R3E 0V9
Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, lessmore » EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.« less
Vaxvec: The first web-based recombinant vaccine vector database and its data analysis
Deng, Shunzhou; Martin, Carly; Patil, Rasika; Zhu, Felix; Zhao, Bin; Xiang, Zuoshuang; He, Yongqun
2015-01-01
A recombinant vector vaccine uses an attenuated virus, bacterium, or parasite as the carrier to express a heterologous antigen(s). Many recombinant vaccine vectors and related vaccines have been developed and extensively investigated. To compare and better understand recombinant vectors and vaccines, we have generated Vaxvec (http://www.violinet.org/vaxvec), the first web-based database that stores various recombinant vaccine vectors and those experimentally verified vaccines that use these vectors. Vaxvec has now included 59 vaccine vectors that have been used in 196 recombinant vector vaccines against 66 pathogens and cancers. These vectors are classified to 41 viral vectors, 15 bacterial vectors, 1 parasitic vector, and 1 fungal vector. The most commonly used viral vaccine vectors are double-stranded DNA viruses, including herpesviruses, adenoviruses, and poxviruses. For example, Vaxvec includes 63 poxvirus-based recombinant vaccines for over 20 pathogens and cancers. Vaxvec collects 30 recombinant vector influenza vaccines that use 17 recombinant vectors and were experimentally tested in 7 animal models. In addition, over 60 protective antigens used in recombinant vector vaccines are annotated and analyzed. User-friendly web-interfaces are available for querying various data in Vaxvec. To support data exchange, the information of vaccine vectors, vaccines, and related information is stored in the Vaccine Ontology (VO). Vaxvec is a timely and vital source of vaccine vector database and facilitates efficient vaccine vector research and development. PMID:26403370
Effects of H sub 2 S addition on the performance of fresh vs. used CoMo catalysts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rankel, L.A.
1991-01-01
When a Co/Mo catalyst is used for processing vanadium-containing heavy oils, vanadium deposits on the catalyst. As the amount of vanadium on the CoMo catalyst increases, the catalytic effects of CoMo decline and the presence of vanadium starts to influence the hydroprocessing products. Model feeds have been used to explore the changes in the catalytic activity of CoMo, aged CoMo, and VS{sub x} on alumina. Desulfurization, denitrogenation, deoxygenation, aromatics hydrogenation, and metals removal were monitored. This paper reports that, upon the addition of hydrogen sulfide to hydrogen, improvements in the catalysts for aromatics hydrogenation, denitrogenation and metals removal were observed.
Versatile generation of optical vector fields and vector beams using a non-interferometric approach.
Tripathi, Santosh; Toussaint, Kimani C
2012-05-07
We present a versatile, non-interferometric method for generating vector fields and vector beams which can produce all the states of polarization represented on a higher-order Poincaré sphere. The versatility and non-interferometric nature of this method is expected to enable exploration of various exotic properties of vector fields and vector beams. To illustrate this, we study the propagation properties of some vector fields and find that, in general, propagation alters both their intensity and polarization distribution, and more interestingly, converts some vector fields into vector beams. In the article, we also suggest a modified Jones vector formalism to represent vector fields and vector beams.
VectorBase: a home for invertebrate vectors of human pathogens
Lawson, Daniel; Arensburger, Peter; Atkinson, Peter; Besansky, Nora J.; Bruggner, Robert V.; Butler, Ryan; Campbell, Kathryn S.; Christophides, George K.; Christley, Scott; Dialynas, Emmanuel; Emmert, David; Hammond, Martin; Hill, Catherine A.; Kennedy, Ryan C.; Lobo, Neil F.; MacCallum, M. Robert; Madey, Greg; Megy, Karine; Redmond, Seth; Russo, Susan; Severson, David W.; Stinson, Eric O.; Topalis, Pantelis; Zdobnov, Evgeny M.; Birney, Ewan; Gelbart, William M.; Kafatos, Fotis C.; Louis, Christos; Collins, Frank H.
2007-01-01
VectorBase () is a web-accessible data repository for information about invertebrate vectors of human pathogens. VectorBase annotates and maintains vector genomes providing an integrated resource for the research community. Currently, VectorBase contains genome information for two organisms: Anopheles gambiae, a vector for the Plasmodium protozoan agent causing malaria, and Aedes aegypti, a vector for the flaviviral agents causing Yellow fever and Dengue fever. PMID:17145709
Vaxvec: The first web-based recombinant vaccine vector database and its data analysis.
Deng, Shunzhou; Martin, Carly; Patil, Rasika; Zhu, Felix; Zhao, Bin; Xiang, Zuoshuang; He, Yongqun
2015-11-27
A recombinant vector vaccine uses an attenuated virus, bacterium, or parasite as the carrier to express a heterologous antigen(s). Many recombinant vaccine vectors and related vaccines have been developed and extensively investigated. To compare and better understand recombinant vectors and vaccines, we have generated Vaxvec (http://www.violinet.org/vaxvec), the first web-based database that stores various recombinant vaccine vectors and those experimentally verified vaccines that use these vectors. Vaxvec has now included 59 vaccine vectors that have been used in 196 recombinant vector vaccines against 66 pathogens and cancers. These vectors are classified to 41 viral vectors, 15 bacterial vectors, 1 parasitic vector, and 1 fungal vector. The most commonly used viral vaccine vectors are double-stranded DNA viruses, including herpesviruses, adenoviruses, and poxviruses. For example, Vaxvec includes 63 poxvirus-based recombinant vaccines for over 20 pathogens and cancers. Vaxvec collects 30 recombinant vector influenza vaccines that use 17 recombinant vectors and were experimentally tested in 7 animal models. In addition, over 60 protective antigens used in recombinant vector vaccines are annotated and analyzed. User-friendly web-interfaces are available for querying various data in Vaxvec. To support data exchange, the information of vaccine vectors, vaccines, and related information is stored in the Vaccine Ontology (VO). Vaxvec is a timely and vital source of vaccine vector database and facilitates efficient vaccine vector research and development. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gonzales, Gustavo F.; Zevallos, Alisson; Gonzales-Castañeda, Cynthia; Nuñez, Denisse; Gastañaga, Carmen; Cabezas, César; Naeher, Luke; Levy, Karen; Steenland, Kyle
2015-01-01
RESUMEN El presente artículo es una revisión sobre la contaminación del agua, el aire y el efecto del cambio climático en la salud de la población peruana. Uno de los principales contaminantes del aire es el material particulado menor de 2,5 μ (PM 2,5), en la ciudad de Lima, anualmente 2300 muertes prematuras son atribuibles a este contaminante. Otro problema es la contaminación del aire domiciliario por el uso de cocinas con combustible de biomasa, donde la exposición excesiva a PM 2,5 dentro de las casas es responsable de aproximadamente 3000 muertes prematuras anuales entre adultos, con otro número desconocido de muertes entre niños debido a infecciones respiratorias. La contaminación del agua tiene como principales causas los desagües vertidos directamente a los ríos, minerales (arsénico) de varias fuentes, y fallas de las plantas de tratamiento. En el Perú, el cambio climático puede impactar en la frecuencia y severidad del fenómeno de El Niño oscilación del sur (ENSO) que se ha asociado con un incremento en los casos de enfermedades como cólera, malaria y dengue. El cambio climático incrementa la temperatura y puede extender las áreas afectadas por enfermedades transmitidas por vectores, además de tener efecto en la disponibilidad del agua y en la contaminación del aire. En conclusión, el Perú, pasa por una transición de factores de riesgo ambientales, donde coexisten riesgos tradicionales y modernos, y persisten los problemas infecciosos y crónicos, algunos de los cuales se asocian con problemas de contaminación de agua y de aire. PMID:25418656
Fredriksson, Alexandru; Trzebiatowska-Krzynska, Aleksandra; Dyverfeldt, Petter; Engvall, Jan; Ebbers, Tino; Carlhäll, Carl-Johan
2018-04-01
To assess right ventricular (RV) turbulent kinetic energy (TKE) in patients with repaired Tetralogy of Fallot (rToF) and a spectrum of pulmonary regurgitation (PR), as well as to investigate the relationship between these 4D flow markers and RV remodeling. Seventeen patients with rToF and 10 healthy controls were included in the study. Patients were divided into two groups based on PR fraction: one lower PR fraction group (≤11%) and one higher PR fraction group (>11%). Field strength/sequences: 3D cine phase contrast (4D flow), 2D cine phase contrast (2D flow), and balanced steady-state free precession (bSSFP) at 1.5T. The RV volume was segmented in the morphologic short-axis images and TKE parameters were computed inside the segmented RV volume throughout diastole. Statistical tests: One-way analysis of variance with Bonferroni post-hoc test; unpaired t-test; Pearson correlation coefficients; simple and stepwise multiple regression models; intraclass correlation coefficient (ICC). The higher PR fraction group had more remodeled RVs (140 ± 25 vs. 107 ± 22 [lower PR fraction, P < 0.01] and 93 ± 15 ml/m 2 [healthy, P < 0.001] for RV end-diastolic volume index [RVEDVI]) and higher TKE values (5.95 ± 3.15 vs. 2.23 ± 0.81 [lower PR fraction, P < 0.01] and 1.91 ± 0.78 mJ [healthy, P < 0.001] for Peak Total RV TKE). Multiple regression analysis between RVEDVI and 4D/2D flow parameters showed that Peak Total RV TKE was the strongest predictor of RVEDVI (R 2 = 0.47, P = 0.002). The 4D flow-specific TKE markers showed a slightly stronger association with RV remodeling than conventional 2D flow PR parameters. These results suggest novel hemodynamic aspects of PR in the development of late complications after ToF repair. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1043-1053. © 2017 International Society for Magnetic Resonance in Medicine.
Bourfiss, Mimount; Vigneault, Davis M; Aliyari Ghasebeh, Mounes; Murray, Brittney; James, Cynthia A; Tichnell, Crystal; Mohamed Hoesein, Firdaus A; Zimmerman, Stefan L; Kamel, Ihab R; Calkins, Hugh; Tandri, Harikrishna; Velthuis, Birgitta K; Bluemke, David A; Te Riele, Anneline S J M
2017-09-01
Regional right ventricular (RV) dysfunction is the hallmark of Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy (ARVD/C), but is currently only qualitatively evaluated in the clinical setting. Feature Tracking Cardiovascular Magnetic Resonance (FT-CMR) is a novel quantitative method that uses cine CMR to calculate strain values. However, most prior FT-CMR studies in ARVD/C have focused on global RV strain using different software methods, complicating implementation of FT-CMR in clinical practice. We aimed to assess the clinical value of global and regional strain using FT-CMR in ARVD/C and to determine differences between commercially available FT-CMR software packages. We analyzed cine CMR images of 110 subjects (39 overt ARVD/C [mutation+/phenotype+], 40 preclinical ARVD/C [mutation+/phenotype-] and 31 control) for global and regional (subtricuspid, anterior, apical) RV strain in the horizontal longitudinal axis using four FT-CMR software methods (Multimodality Tissue Tracking, TomTec, Medis and Circle Cardiovascular Imaging). Intersoftware agreement was assessed using Bland Altman plots. For global strain, all methods showed reduced strain in overt ARVD/C patients compared to control subjects (p < 0.041), whereas none distinguished preclinical from control subjects (p > 0.275). For regional strain, overt ARVD/C patients showed reduced strain compared to control subjects in all segments which reached statistical significance in the subtricuspid region for all software methods (p < 0.037), in the anterior wall for two methods (p < 0.005) and in the apex for one method (p = 0.012). Preclinical subjects showed abnormal subtricuspid strain compared to control subjects using one of the software methods (p = 0.009). Agreement between software methods for absolute strain values was low (Intraclass Correlation Coefficient = 0.373). Despite large intersoftware variability of FT-CMR derived strain values, all four software methods distinguished overt ARVD/C patients from control subjects by both global and subtricuspid strain values. In the subtricuspid region, one software package distinguished preclinical from control subjects, suggesting the potential to identify early ARVD/C prior to overt disease expression.
SU-E-J-35: Using CBCT as the Alternative Method of Assessing ITV Volume
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liao, Y; Turian, J; Templeton, A
2015-06-15
Purpose To study the accuracy of Internal Target Volumes (ITVs) created on cone beam CT (CBCT) by comparing the visible target volume on CBCT to volumes (GTV, ITV, and PTV) outlined on free breathing (FB) CT and 4DCT. Methods A Quasar Cylindrical Motion Phantom with a 3cm diameter ball (14.14 cc) embedded within a cork insert was set up to simulate respiratory motion with a period of 4 seconds and amplitude of 2cm superioinferiorly and 1cm anterioposteriorly. FBCT and 4DCT images were acquired. A PTV-4D was created on the 4DCT by applying a uniform margin of 5mm to the ITV-CT.more » PTV-FB was created by applying a margin of the motion range plus 5mm, i.e. total of 1.5cm laterally and 2.5cm superioinferiorly to the GTV outlined on the FBCT. A dynamic conformal arc was planned to treat the PTV-FB with 1mm margin. A CBCT was acquired before the treatment, on which the target was delineated. During the treatment, the position of the target was monitored using the EPID in cine mode. Results ITV-CBCT and ITV-CT were measured to be 56.6 and 62.7cc, respectively, with a Dice Coefficient (DC) of 0.94 and disagreement in center of mass (COM) of 0.59 mm. On the other hand, GTV-FB was 11.47cc, 19% less than the known volume of the ball. PTV-FB and PTV-4D were 149 and 116 cc, with a DC of 0.71. Part of the ITV-CT was not enclosed by the PTV-FB despite the large margin. The cine EPID images have confirmed geometrical misses of the target. Similar under-coverage was observed in one clinical case and captured by the CBCT, where the implanted fiducials moved outside PTV-FB. Conclusion ITV-CBCT is in good agreement with ITV-CT. When 4DCT was not available, CBCT can be an effective alternative in determining and verifying the PTV margin.« less
Photographic Method For Measurement Of Image Intensifier Tube Contrast
NASA Astrophysics Data System (ADS)
Moore, Robert J.
1981-07-01
An important parameter in an image intensifier-based imaging system is the contrast of the image intensifier tube itself. This paper presents a photographic method for the measurement of the large-scale contrast of an image intensifier tube at the system level which can be performed in the clinical setting with equipment normally found in a modern Radiology Department. A strip of Lead is positioned on-center at the bottom of the grid so that a line image of 100% contrast will be presented to the input phosphor of the image intensifier when the x-ray tube is energized at low kilovoltage. The output phosphor is photographed either with an existing fluorographic camera (photospot or cine) on the imaging tower, or with a 35-mm SLR camera loaded with orthochromatic cine film through the collimating lens of the system from the position normally occupied by the television camera, during fluoroscopy, if no other camera is present on the imaging tower. The resultant on-frame optical density is measured with a densitometer in the central part of the developed frame adjacent to and behind the image of the Lead strip. These optical density readings are converted into a ratio of light intensities from the corresponding regions on the output phosphor using the characteristic curve for the type of film employed, which is obtained by means of light sensitometry. The percent contrast is then calculated from (ratio of intensities - 1)/(ratio of intensities + 1)) X 100. Using data for a variety of CsI image intensifiers used for both gastrointestinal and vascular studies, the method is shown to give measured percent contrasts with a reproducibility of no worse than-2%, independent of type of camera used or type of sensitometer used. Standards of acceptable performance based on the author's experience with this technique over the past five years are presented for systems designed for Barium studies and for systems designed for Iodine studies. The relationship between the percent contrast as defined here, the veiling glare as defined by Siedband, and the contrast ratio as normally defined is discussed, as well as the relevance of large-scale contrast of an image intensifier tube.
Miquel, M E; Hill, D L G; Baker, E J; Qureshi, S A; Simon, R D B; Keevil, S F; Razavi, R S
2003-06-01
The present study was designed to evaluate the feasibility and clinical usefulness of three-dimensional (3D) reconstruction of intra-cardiac anatomy from a series of two-dimensional (2D) MR images using commercially available software. Sixteen patients (eight with structurally normal hearts but due to have catheter radio-frequency ablation of atrial tachyarrhythmias and eight with atrial septal defects (ASD) due for trans-catheter closure) and two volunteers were imaged at 1T. For each patient, a series of ECG-triggered images (5 mm thick slices, 2-3 mm apart) were acquired during breath holding. Depending on image quality, T1- or T2-weighted spin-echo images or gradient-echo cine images were used. The 3D reconstruction was performed off-line: the blood pools within cardiac chambers and great vessels were semi-automatically segmented, their outer surface was extracted using a marching cube algorithm and rendered. Intra- and inter-observer variability, effect of breath-hold position and differences between pulse sequences were assessed by imaging a volunteer. The 3D reconstructions were assessed by three cardiologists and compared with the 2D MR images and with 2D and 3D trans-esophagal and intra-cardiac echocardiography obtained during interventions. In every case, an anatomically detailed 3D volume was obtained. In the two patients where a 3 mm interval between slices was used, the resolution was not as good but it was still possible to visualize all the major anatomical structures. Spin-echo images lead to reconstructions more detailed than those obtained from gradient-echo images. However, gradient-echo images are easier to segment due to their greater contrast. Furthermore, because images were acquired at least at ten points in the cardiac cycles for every slice it was possible to reconstruct a cine loop and, for example, to visualize the evolution of the size and margins of the ASD during the cardiac cycle. 3D reconstruction proved to be an effective way to assess the relationship between the different parts of the cardiac anatomy. The technique was useful in planning interventions in these patients.
NASA Astrophysics Data System (ADS)
Negahdar, MJ; Shakeri, M.; McDowell, E.; Wells, J.; Vitaz, T.; Harkema, S.; Amini, A.
2011-03-01
MRI velocimetry (also known as phase-contrast MRI) is a powerful tool for quantification of cerebrospinal fluid (CSF) flow in various regions of the brain and craniospinal junction and has been accepted as a diagnostic tool to assist with the diagnosis of certain conditions such as hydrocephalus and chiari malformations. Cerebrospinal fluid is continually produced in the ventricles of the brain, flows through the ventricular system and then out and around the brain and spinal cord and is reabsorbed over the convexity of the brain. Any disease process which either impedes the normal pattern of flow or restricts the area where flow occurs can change the pattern of these waveforms with the direction and velocity of flow being determined by the pressure transmitted from the pulsation of the heart and circulation of blood within the central nervous system. Therefore, we hypothesized that phase-contrast MRI could eventually be used as a diagnostic aid in determining the degree of spinal cord compression following injury to the cervical or thoracic spine. In this study, we examined CSF flow in 3 normal subjects and 2 subjects with non-acute injuries in the cervical spine using Cine phasecontrast MRI. CSF flow analysis was performed using an in-house developed software. The flow waveform was calculated in both normal subjects (n=3) as well as subjects with spinal cord injury in the cervical spine (n=2). The bulk flow at C2 was measured to be 0.30 +/- 0.05 cc, at 5 cm distal to C2, it was 0.19+/- 0.07 cc, and at 10 cm distal to C2, it was 0.17+/- 0.05 cc. These results were in good agreement with previously published results. In patients with spinal cord injury, at the site of injury in the cervical spine, bulk flow was found to be 0.08 +/- 0.12 cc, at 5 cm proximal to the site of injury it was found to be 0.18 +/- 0.07 cc, and at 5 cm distal to the site of injury, it was found to be 0.12 +/- 0.01 cc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, X; Lin, J; Diwanji, T
2014-06-01
Purpose: Recently, template matching has been shown to be able to track tumor motion on cine-MRI images. However, artifacts such as deformation, rotation, and/or out-of-plane movement could seriously degrade the performance of this technique. In this work, we demonstrate the utility of multiple templates derived from different phases of tumor motion in reducing the negative effects of artifacts and improving the accuracy of template matching methods. Methods: Data from 2 patients with large tumors and significant tumor deformation were analyzed from a group of 12 patients from an earlier study. Cine-MRI (200 frames) imaging was performed while the patients weremore » instructed to breathe normally. Ground truth tumor position was established on each frame manually by a radiation oncologist. Tumor positions were also automatically determined using template matching with either single or multiple (5) templates. The tracking errors, defined as the absolute differences in tumor positions determined by the manual and automated methods, when using either single or multiple templates were compared in both the AP and SI directions, respectively. Results: Using multiple templates reduced the tracking error of template matching. In the SI direction where the tumor movement and deformation were significant, the mean tracking error decreased from 1.94 mm to 0.91 mm (Patient 1) and from 6.61 mm to 2.06 mm (Patient 2). In the AP direction where the tumor movement was small, the reduction of the mean tracking error was significant in Patient 1 (from 3.36 mm to 1.04 mm), but not in Patient 2 ( from 3.86 mm to 3.80 mm). Conclusion: This study shows the effectiveness of using multiple templates in improving the performance of template matching when artifacts like large tumor deformation or out-of-plane motion exists. Accurate tumor tracking capabilities can be integrated with MRI guided radiation therapy systems. This work was supported in part by grants from NIH/NCI CA 124766 and Varian Medical Systems, Palo Alto, CA.« less
WE-G-18C-06: Is Diaphragm Motion a Good Surrogate for Liver Tumor Motion?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, J; School of Information Science and Engineering, Shandong University, Jinan, Shandong; Cai, J
2014-06-15
Purpose: To investigate whether diaphragm motion is a good surrogate for liver tumor motion by comparing their motion trajectories obtained from cine-MRI. Methods: Fourteen patients with hepatocellular carcinoma (10/14) or liver metastases (4/14) undergoing radiation therapy were included in this study. All patients underwent single-slice 2D cine-MRI simulations across the center of the tumor in three orthogonal planes. Tumor and diaphragm motion trajectories in the superior-inferior (SI), anteriorposterior (AP), and medial-lateral (ML) directions were obtained using the normalized cross-correlation based tracking technique. Agreement between tumor and diaphragm motions was assessed by calculating the phase difference percentage (PDP), intra-class correlation coefficientmore » (ICC), Bland-Altman analysis (Diffs) and paired t-test. The distance (D) between tumor and tracked diaphragm area was analyzed to understand its impact on the correlation between tumor and diaphragm motions. Results: Of all patients, the means (±standard deviations) of PDP were 7.1 (±1.1)%, 4.5 (±0.5)% and 17.5 (±4.5)% in the SI, AP and ML directions, respectively. The means of ICC were 0.98 (±0.02), 0.97 (±0.02), and 0.08 (±0.06) in the SI, AP and ML directions, respectively. The Diffs were 2.8 (±1.4) mm, 2.4 (±1.1) mm, and 2.2 (±0.5) mm in the SI, AP and ML directions, respectively. The p-values derived from the paired t-test were < 0.02 in SI and AP directions, whereas were > 0.58 in ML direction primarily due to the small motion in ML direction. Tumor and diaphragmatic motion had high concordance when the distance between the tumor and tracked diaphragm areas was small. Conclusion: Preliminary results showed that liver tumor motion had good correlations with diaphragm motion in the SI and AP directions, indicating diaphragm motion in the SI and AP directions could potentially be a reliable surrogate for liver tumor motion. NIH (1R21CA165384-01A1), Golfers Against Cancer (GAC) Foundation, The China Scholarship Council (CSC)« less
Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Kottmaier, Marc; Semmler, Verena; Telishevska, Marta; Brkic, Amir; Grebmer, Christian; Lennerz, Carsten; Kolb, Christof; Hessling, Gabriele; Deisenhofer, Isabel
2016-01-01
Aims This study presents and evaluates the impact of a new lowest-dose fluoroscopy protocol (Siemens AG), especially designed for electrophysiology (EP) procedures, on X-ray dose levels. Methods and results From October 2014 to March 2015, 140 patients underwent an EP study on an Artis zee angiography system. The standard low-dose protocol was operated at 23 nGy (fluoroscopy) and at 120 nGy (cine-loop), the new lowest-dose protocol was operated at 8 nGy (fluoroscopy) and at 36 nGy (cine-loop). Procedural data, X-ray times, and doses were analysed in 100 complex left atrial and in 40 standard EP procedures. The resulting dose–area products were 877.9 ± 624.7 µGym² (n = 50 complex procedures, standard low dose), 199 ± 159.6 µGym² (n = 50 complex procedures, lowest dose), 387.7 ± 36.0 µGym² (n = 20 standard procedures, standard low dose), and 90.7 ± 62.3 µGym² (n = 20 standard procedures, lowest dose), P < 0.01. In the low-dose and lowest-dose groups, procedure times were 132.6 ± 35.7 vs. 126.7 ± 34.7 min (P = 0.40, complex procedures) and 72.3 ± 20.9 vs. 85.2 ± 44.1 min (P = 0.24, standard procedures), radiofrequency (RF) times were 53.8 ± 26.1 vs. 50.4 ± 29.4 min (P = 0.54, complex procedures) and 10.1 ± 9.9 vs. 12.2 ± 14.7 min (P = 0.60, standard procedures). One complication occurred in the standard low-dose and lowest-dose groups (P = 1.0). Conclusion The new lowest-dose imaging protocol reduces X-ray dose levels by 77% compared with the currently available standard low-dose protocol. From an operator standpoint, lowest X-ray dose levels create a different, reduced image quality. The new image quality did not significantly affect procedure or RF times and did not result in higher complication rates. Regarding radiological protection, operating at lowest-dose settings should become standard in EP procedures. PMID:26589627
Mordini, Federico E; Haddad, Tariq; Hsu, Li-Yueh; Kellman, Peter; Lowrey, Tracy B; Aletras, Anthony H; Bandettini, W Patricia; Arai, Andrew E
2014-01-01
This study's primary objective was to determine the sensitivity, specificity, and accuracy of fully quantitative stress perfusion cardiac magnetic resonance (CMR) versus a reference standard of quantitative coronary angiography. We hypothesized that fully quantitative analysis of stress perfusion CMR would have high diagnostic accuracy for identifying significant coronary artery stenosis and exceed the accuracy of semiquantitative measures of perfusion and qualitative interpretation. Relatively few studies apply fully quantitative CMR perfusion measures to patients with coronary disease and comparisons to semiquantitative and qualitative methods are limited. Dual bolus dipyridamole stress perfusion CMR exams were performed in 67 patients with clinical indications for assessment of myocardial ischemia. Stress perfusion images alone were analyzed with a fully quantitative perfusion (QP) method and 3 semiquantitative methods including contrast enhancement ratio, upslope index, and upslope integral. Comprehensive exams (cine imaging, stress/rest perfusion, late gadolinium enhancement) were analyzed qualitatively with 2 methods including the Duke algorithm and standard clinical interpretation. A 70% or greater stenosis by quantitative coronary angiography was considered abnormal. The optimum diagnostic threshold for QP determined by receiver-operating characteristic curve occurred when endocardial flow decreased to <50% of mean epicardial flow, which yielded a sensitivity of 87% and specificity of 93%. The area under the curve for QP was 92%, which was superior to semiquantitative methods: contrast enhancement ratio: 78%; upslope index: 82%; and upslope integral: 75% (p = 0.011, p = 0.019, p = 0.004 vs. QP, respectively). Area under the curve for QP was also superior to qualitative methods: Duke algorithm: 70%; and clinical interpretation: 78% (p < 0.001 and p < 0.001 vs. QP, respectively). Fully quantitative stress perfusion CMR has high diagnostic accuracy for detecting obstructive coronary artery disease. QP outperforms semiquantitative measures of perfusion and qualitative methods that incorporate a combination of cine, perfusion, and late gadolinium enhancement imaging. These findings suggest a potential clinical role for quantitative stress perfusion CMR. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Cardiovascular magnetic resonance physics for clinicians: part II
2012-01-01
This is the second of two reviews that is intended to cover the essential aspects of cardiovascular magnetic resonance (CMR) physics in a way that is understandable and relevant to clinicians using CMR in their daily practice. Starting with the basic pulse sequences and contrast mechanisms described in part I, it briefly discusses further approaches to accelerate image acquisition. It then continues by showing in detail how the contrast behaviour of black blood fast spin echo and bright blood cine gradient echo techniques can be modified by adding rf preparation pulses to derive a number of more specialised pulse sequences. The simplest examples described include T2-weighted oedema imaging, fat suppression and myocardial tagging cine pulse sequences. Two further important derivatives of the gradient echo pulse sequence, obtained by adding preparation pulses, are used in combination with the administration of a gadolinium-based contrast agent for myocardial perfusion imaging and the assessment of myocardial tissue viability using a late gadolinium enhancement (LGE) technique. These two imaging techniques are discussed in more detail, outlining the basic principles of each pulse sequence, the practical steps required to achieve the best results in a clinical setting and, in the case of perfusion, explaining some of the factors that influence current approaches to perfusion image analysis. The key principles of contrast-enhanced magnetic resonance angiography (CE-MRA) are also explained in detail, especially focusing on timing of the acquisition following contrast agent bolus administration, and current approaches to achieving time resolved MRA. Alternative MRA techniques that do not require the use of an endogenous contrast agent are summarised, and the specialised pulse sequence used to image the coronary arteries, using respiratory navigator gating, is described in detail. The article concludes by explaining the principle behind phase contrast imaging techniques which create images that represent the phase of the MR signal rather than the magnitude. It is shown how this principle can be used to generate velocity maps by designing gradient waveforms that give rise to a relative phase change that is proportional to velocity. Choice of velocity encoding range and key pitfalls in the use of this technique are discussed. PMID:22995744
High performance MRI simulations of motion on multi-GPU systems
2014-01-01
Background MRI physics simulators have been developed in the past for optimizing imaging protocols and for training purposes. However, these simulators have only addressed motion within a limited scope. The purpose of this study was the incorporation of realistic motion, such as cardiac motion, respiratory motion and flow, within MRI simulations in a high performance multi-GPU environment. Methods Three different motion models were introduced in the Magnetic Resonance Imaging SIMULator (MRISIMUL) of this study: cardiac motion, respiratory motion and flow. Simulation of a simple Gradient Echo pulse sequence and a CINE pulse sequence on the corresponding anatomical model was performed. Myocardial tagging was also investigated. In pulse sequence design, software crushers were introduced to accommodate the long execution times in order to avoid spurious echoes formation. The displacement of the anatomical model isochromats was calculated within the Graphics Processing Unit (GPU) kernel for every timestep of the pulse sequence. Experiments that would allow simulation of custom anatomical and motion models were also performed. Last, simulations of motion with MRISIMUL on single-node and multi-node multi-GPU systems were examined. Results Gradient Echo and CINE images of the three motion models were produced and motion-related artifacts were demonstrated. The temporal evolution of the contractility of the heart was presented through the application of myocardial tagging. Better simulation performance and image quality were presented through the introduction of software crushers without the need to further increase the computational load and GPU resources. Last, MRISIMUL demonstrated an almost linear scalable performance with the increasing number of available GPU cards, in both single-node and multi-node multi-GPU computer systems. Conclusions MRISIMUL is the first MR physics simulator to have implemented motion with a 3D large computational load on a single computer multi-GPU configuration. The incorporation of realistic motion models, such as cardiac motion, respiratory motion and flow may benefit the design and optimization of existing or new MR pulse sequences, protocols and algorithms, which examine motion related MR applications. PMID:24996972
Lin, Kai; Collins, Jeremy D; Lloyd-Jones, Donald M; Jolly, Marie-Pierre; Li, Debiao; Markl, Michael; Carr, James C
2016-03-01
To assess the performance of automated quantification of left ventricular function and mass based on heart deformation analysis (HDA) in asymptomatic older adults. This study complied with Health Insurance Portability and Accountability Act regulations. Following the approval of the institutional review board, 160 asymptomatic older participants were recruited for cardiac magnetic resonance imaging including two-dimensional cine images covering the entire left ventricle in short-axis view. Data analysis included the calculation of left ventricular ejection fraction (LVEF), left ventricular mass (LVM), and cardiac output (CO) using HDA and standard global cardiac function analysis (delineation of end-systolic and end-diastolic left ventricle epi- and endocardial borders). The agreement between methods was evaluated using intraclass correlation coefficient (ICC) and coefficient of variation (CoV). HDA had a shorter processing time than the standard method (1.5 ± 0.3 min/case vs. 5.8 ± 1.4 min/case, P < 0.001). There was good agreement for LVEF (ICC = 0.552, CoV = 10.5%), CO (ICC = 0.773, CoV = 13.5%), and LVM (ICC = 0.859, CoV = 14.5%) acquired with the standard method and HDA. There was a systemic bias toward lower LVEF (62.8% ± 8.3% vs. 69.3% ± 6.7%, P < 0.001) and CO (4.4 ± 1.0 L/min vs. 4.8 ± 1.3 L/min, P < 0.001) by HDA compared to the standard technique. Conversely, HDA overestimated LVM (114.8 ± 30.1 g vs. 100.2 ± 29.0 g, P < 0.001) as compared to the reference method. HDA has the potential to measure LVEF, CO, and LVM without the need for user interaction based on standard cardiac two-dimensional cine images. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
James, Susan H; Wald, Rachel; Wintersperger, Bernd J; Jimenez-Juan, Laura; Deva, Djeven; Crean, Andrew M; Nguyen, Elsie; Paul, Narinder S; Ley, Sebastian
2013-08-01
The left ventricle (LV) is routinely assessed with cardiac magnetic resonance imaging (MRI) by using short-axis orientation; it remains unclear whether the right ventricle (RV) can also be adequately assessed in this orientation or whether dedicated axial orientation is required. We used phase-contrast (PC) flow measurements in the main pulmonary artery (MPA) and the ascending aorta (Aorta) as nonvolumetric standard of reference and compared RV and LV volumes in short-axis and axial orientations. A retrospective analysis identified 30 patients with cardiac MRI data sets. Patients underwent MRI (1.5 T or 3 T), with retrospectively gated cine steady-state free-precession in axial and short-axis orientations. PC flow analyses of MPA and Aorta were used as the reference measure of RV and LV output. There was a high linear correlation between MPA-PC flow and RV-stroke volume (SV) short axis (r = 0.9) and RV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 1.4 mL for RV axial and -2.3 mL for RV-short-axis vs MPA-PC flow. There was a high linear correlation between Aorta-PC flow and LV-SV short-axis (r = 0.9) and LV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 4.8 m for LV short axis and 7.0 mL for LV axial vs Aorta-PC flow. There was no significant difference (P = .6) between short-axis-LV SV and short-axis-RV SV. No significant impact of the slice acquisition orientation for determination of RV and LV stroke volumes was found. Therefore, cardiac magnetic resonance workflow does not need to be extended by an axial data set for patients without complex cardiac disease for assessment of biventricular function and volumes. Copyright © 2013 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Eichenberger, Alexandre E; Gschwind, Michael K; Gunnels, John A
2014-02-11
Mechanisms for performing a complex matrix multiplication operation are provided. A vector load operation is performed to load a first vector operand of the complex matrix multiplication operation to a first target vector register. The first vector operand comprises a real and imaginary part of a first complex vector value. A complex load and splat operation is performed to load a second complex vector value of a second vector operand and replicate the second complex vector value within a second target vector register. The second complex vector value has a real and imaginary part. A cross multiply add operation is performed on elements of the first target vector register and elements of the second target vector register to generate a partial product of the complex matrix multiplication operation. The partial product is accumulated with other partial products and a resulting accumulated partial product is stored in a result vector register.
TUBERCULOSIS COMO ENFERMEDAD OCUPACIONAL
Mendoza-Ticona, Alberto
2014-01-01
Existe evidencia suficiente para declarar a la tuberculosis como enfermedad ocupacional en diversos profesionales especialmente entre los trabajadores de salud. En el Perú están normados y reglamentados los derechos laborales inherentes a la tuberculosis como enfermedad ocupacional, como la cobertura por discapacidad temporal o permanente. Sin embargo, estos derechos aún no han sido suficientemente socializados. En este trabajo se presenta información sobre el riesgo de adquirir tuberculosis en el lugar de trabajo, se revisan las evidencias para declarar a la tuberculosis como enfermedad ocupacional en trabajadores de salud y se presenta la legislación peruana vigente al respecto. PMID:22858771
Vector adaptive predictive coder for speech and audio
NASA Technical Reports Server (NTRS)
Chen, Juin-Hwey (Inventor); Gersho, Allen (Inventor)
1990-01-01
A real-time vector adaptive predictive coder which approximates each vector of K speech samples by using each of M fixed vectors in a first codebook to excite a time-varying synthesis filter and picking the vector that minimizes distortion. Predictive analysis for each frame determines parameters used for computing from vectors in the first codebook zero-state response vectors that are stored at the same address (index) in a second codebook. Encoding of input speech vectors s.sub.n is then carried out using the second codebook. When the vector that minimizes distortion is found, its index is transmitted to a decoder which has a codebook identical to the first codebook of the decoder. There the index is used to read out a vector that is used to synthesize an output speech vector s.sub.n. The parameters used in the encoder are quantized, for example by using a table, and the indices are transmitted to the decoder where they are decoded to specify transfer characteristics of filters used in producing the vector s.sub.n from the receiver codebook vector selected by the vector index transmitted.
Method and apparatus for optimized processing of sparse matrices
Taylor, Valerie E.
1993-01-01
A computer architecture for processing a sparse matrix is disclosed. The apparatus stores a value-row vector corresponding to nonzero values of a sparse matrix. Each of the nonzero values is located at a defined row and column position in the matrix. The value-row vector includes a first vector including nonzero values and delimiting characters indicating a transition from one column to another. The value-row vector also includes a second vector which defines row position values in the matrix corresponding to the nonzero values in the first vector and column position values in the matrix corresponding to the column position of the nonzero values in the first vector. The architecture also includes a circuit for detecting a special character within the value-row vector. Matrix-vector multiplication is executed on the value-row vector. This multiplication is performed by multiplying an index value of the first vector value by a column value from a second matrix to form a matrix-vector product which is added to a previous matrix-vector product.
Abbink, Peter; Lemckert, Angelique A C; Ewald, Bonnie A; Lynch, Diana M; Denholtz, Matthew; Smits, Shirley; Holterman, Lennart; Damen, Irma; Vogels, Ronald; Thorner, Anna R; O'Brien, Kara L; Carville, Angela; Mansfield, Keith G; Goudsmit, Jaap; Havenga, Menzo J E; Barouch, Dan H
2007-05-01
Recombinant adenovirus serotype 5 (rAd5) vector-based vaccines are currently being developed for both human immunodeficiency virus type 1 and other pathogens. The potential limitations associated with rAd5 vectors, however, have led to the construction of novel rAd vectors derived from rare Ad serotypes. Several rare serotype rAd vectors have already been described, but a detailed comparison of multiple rAd vectors from subgroups B and D has not previously been reported. Such a comparison is critical for selecting optimal rAd vectors for advancement into clinical trials. Here we describe the construction of three novel rAd vector systems from Ad26, Ad48, and Ad50. We report comparative seroprevalence and immunogenicity studies involving rAd11, rAd35, and rAd50 vectors from subgroup B; rAd26, rAd48, and rAd49 vectors from subgroup D; and rAd5 vectors from subgroup C. All six rAd vectors from subgroups B and D exhibited low seroprevalence in a cohort of 200 individuals from sub-Saharan Africa, and they elicited Gag-specific cellular immune responses in mice both with and without preexisting anti-Ad5 immunity. The rAd vectors from subgroup D were also evaluated using rhesus monkeys and were shown to be immunogenic after a single injection. The rAd26 vectors proved the most immunogenic among the rare serotype rAd vectors studied, although all rare serotype rAd vectors were still less potent than rAd5 vectors in the absence of anti-Ad5 immunity. These studies substantially expand the portfolio of rare serotype rAd vectors that may prove useful as vaccine vectors for the developing world.
Optimum instantaneous impulsive orbital injection to attain a specified asymptotic velocity vector.
NASA Technical Reports Server (NTRS)
Bean, W. C.
1971-01-01
A nalysis of the necessary conditions of Battin for instantaneous orbital injection, with consideration of the uniqueness of his solution, and of the further problem which arises in the degenerate case when radius vector and asymptotic vector are separated by 180 deg. It is shown that when the angular separation between radius vector and asymptotic velocity vector satisfies theta not equal to 180 deg, there are precisely two insertion-velocity vectors which permit attainment of the target asymptotic velocity vector, one yielding posigrade, the other retrograde motion. When theta equals to 180 deg, there is a family of insertion-velocity vectors which permit attainment of a specified asymptotic velocity vector with a unique insertion-velocity vector for every arbitrary orientation of a target unit angular momentum vector.
Uchida, Naoya; Hargrove, Phillip W.; Lap, Coen J.; Evans, Molly E.; Phang, Oswald; Bonifacino, Aylin C.; Krouse, Allen E.; Metzger, Mark E.; Nguyen, Anh-Dao; Hsieh, Matthew M.; Wolfsberg, Tyra G.; Donahue, Robert E.; Persons, Derek A.; Tisdale, John F.
2012-01-01
Human immunodeficiency virus type 1 (HIV1) vectors poorly transduce rhesus hematopoietic cells due to species-specific restriction factors, including the tripartite motif-containing 5 isoformα (TRIM5α) which targets the HIV1 capsid. We previously developed a chimeric HIV1 (χHIV) vector system wherein the vector genome is packaged with the simian immunodeficiency virus (SIV) capsid for efficient transduction of both rhesus and human CD34+ cells. To evaluate whether χHIV vectors could efficiently transduce rhesus hematopoietic repopulating cells, we performed a competitive repopulation assay in rhesus macaques, in which half of the CD34+ cells were transduced with standard SIV vectors and the other half with χHIV vectors. As compared with SIV vectors, χHIV vectors achieved higher vector integration, and the transgene expression rates were two- to threefold higher in granulocytes and red blood cells and equivalent in lymphocytes and platelets for 2 years. A recipient of χHIV vector-only transduced cells reached up to 40% of transgene expression rates in granulocytes and lymphocytes and 20% in red blood cells. Similar to HIV1 and SIV vectors, χHIV vector frequently integrated into gene regions, especially into introns. In summary, our χHIV vector demonstrated efficient transduction for rhesus long-term repopulating cells, comparable with SIV vectors. This χHIV vector should allow preclinical testing of HIV1-based therapeutic vectors in large animal models. PMID:22871664
Shah, Benoy N; MacNab, Anita; Lynch, Jane; Hampson, Reinette; Senior, Roxy; Steeds, Richard P
2018-01-01
Stress echocardiography is a widely utilised test in patients with known or suspected coronary artery disease (CAD), valvular heart disease and cardiomyopathies. Its advantages include the ubiquitous availability of echocardiography, lack of ionising radiation, choice of physiological or pharmacological stressors, good diagnostic accuracy and robust supporting evidence base. SE has evolved significantly as a technique over the past three decades and has benefitted considerably from improvements in overall image quality (superior resolution), machine technology (e.g. digital cine-loop acquisition and side-by-side image display) and development of second-generation ultrasound contrast agents that have improved reader confidence and diagnostic accuracy. The purpose of this article is to review the breadth of SE in contemporary clinical cardiology and discuss the recently launched British Society of Echocardiography (BSE) Stress Echocardiography accreditation scheme. PMID:29358185
NASA Astrophysics Data System (ADS)
Lyu, Jingyuan; Nakarmi, Ukash; Zhang, Chaoyi; Ying, Leslie
2016-05-01
This paper presents a new approach to highly accelerated dynamic parallel MRI using low rank matrix completion, partial separability (PS) model. In data acquisition, k-space data is moderately randomly undersampled at the center kspace navigator locations, but highly undersampled at the outer k-space for each temporal frame. In reconstruction, the navigator data is reconstructed from undersampled data using structured low-rank matrix completion. After all the unacquired navigator data is estimated, the partial separable model is used to obtain partial k-t data. Then the parallel imaging method is used to acquire the entire dynamic image series from highly undersampled data. The proposed method has shown to achieve high quality reconstructions with reduction factors up to 31, and temporal resolution of 29ms, when the conventional PS method fails.
Frequency of Apical and Laminal /s/ in Normal and Postglossectomy Patients
Stone, Maureen; Rizk, Susan; Woo, Jonghye; Murano, Emi Z.; Chen, Hegang; Prince, Jerry L.
2015-01-01
American English can be produced with two types of /s/: apical or laminal. These productions differ in that the apical gesture requires independent tongue tip elevation, and the laminal does not. Postglossectomy speakers, who have lost a unilateral portion of the tongue body along the outer edge, lose innervation to the tongue tip. We hypothesize that postglossectomy patients, even those with a preserved tongue tip, will be more likely to use laminal tongue shapes because of reduced control of the tongue tip. This study examines /s/ type, palate height, and related parameters in 24 control participants and 13 patients with lateral resections using cine-MRI and dental casts. Results of this dataset show that palate height affects choice of /s/ in control participants, but not in patients. Patients tend to use laminal /s/. PMID:26157329
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stemkens, B; Glitzner, M; Kontaxis, C
Purpose: To assess the dose deposition in simulated single-fraction MR-Linac treatments of renal cell carcinoma, when inter-cycle respiratory motion variation is taken into account using online MRI. Methods: Three motion characterization methods, with increasing complexity, were compared to evaluate the effect of inter-cycle motion variation and drifts on the accumulated dose for an SBRT kidney MR-Linac treatment: 1) STATIC, in which static anatomy was assumed, 2) AVG-RESP, in which 4D-MRI phase-volumes were time-weighted, based on the respiratory phase and 3) PCA, in which 3D volumes were generated using a PCA-model, enabling the detection of inter-cycle variations and drifts. An experimentalmore » ITV-based kidney treatment was simulated in a 1.5T magnetic field on three volunteer datasets. For each volunteer a retrospectively sorted 4D-MRI (ten respiratory phases) and fast 2D cine-MR images (temporal resolution = 476ms) were acquired to simulate MR-imaging during radiation. For each method, the high spatio-temporal resolution 3D volumes were non-rigidly registered to obtain deformation vector fields (DVFs). Using the DVFs, pseudo-CTs (generated from the 4D-MRI) were deformed and the dose was accumulated for the entire treatment. The accuracies of all methods were independently determined using an additional, orthogonal 2D-MRI slice. Results: Motion was most accurately estimated using the PCA method, which correctly estimated drifts and inter-cycle variations (RMSE=3.2, 2.2, 1.1mm on average for STATIC, AVG-RESP and PCA, compared to the 2DMRI slice). Dose-volume parameters on the ITV showed moderate changes (D99=35.2, 32.5, 33.8Gy for STATIC, AVG-RESP and PCA). AVG-RESP showed distinct hot/cold spots outside the ITV margin, which were more distributed for the PCA scenario, since inter-cycle variations were not modeled by the AVG-RESP method. Conclusion: Dose differences were observed when inter-cycle variations were taken into account. The increased inter-cycle randomness in motion as captured by the PCA model mitigates the local (erroneous) hotspots estimated by the AVG-RESP method.« less
Definition of Contravariant Velocity Components
NASA Technical Reports Server (NTRS)
Hung, Ching-moa; Kwak, Dochan (Technical Monitor)
2002-01-01
In this paper we have reviewed the basics of tensor analysis in an attempt to clarify some misconceptions regarding contravariant and covariant vector components as used in fluid dynamics. We have indicated that contravariant components are components of a given vector expressed as a unique combination of the covariant base vector system and, vice versa, that the covariant components are components of a vector expressed with the contravariant base vector system. Mathematically, expressing a vector with a combination of base vector is a decomposition process for a specific base vector system. Hence, the contravariant velocity components are decomposed components of velocity vector along the directions of coordinate lines, with respect to the covariant base vector system. However, the contravariant (and covariant) components are not physical quantities. Their magnitudes and dimensions are controlled by their corresponding covariant (and contravariant) base vectors.
Li, Chun-Fang
2007-12-15
A unified description of free-space cylindrical vector beams is presented that is an integral transformation solution to the vector Helmholtz equation and the transversality condition. In the paraxial condition, this solution not only includes the known J(1) Bessel-Gaussian vector beam and the axisymmetric Laguerre-Gaussian vector beam that were obtained by solving the paraxial wave equations but also predicts two kinds of vector beam, called a modified Bessel-Gaussian vector beam.
Trapping tsetse flies on water
Laveissière, C.; Camara, M.; Rayaisse, J.B.; Salou, E.; Kagbadouno, M.; Solano, P.
2011-01-01
Riverine tsetse flies such as Glossina palpalis gambiensis and G. tachinoides are the vectors of human and animal trypanosomoses in West Africa. Despite intimate links between tsetse and water, to our knowledge there has never been any attempt to design trapping devices that would catch tsetse on water. In mangrove (Guinea) one challenging issue is the tide, because height above the ground for a trap is a key factor affecting tsetse catches. The trap was mounted on the remains of an old wooden dugout, and attached with rope to nearby branches, thereby allowing it to rise and fall with the tide. Catches showed a very high density of 93.9 flies/”water-trap”/day, which was significantly higher (p < 0.05) than all the catches from other habitats where the classical trap had been used. In savannah, on the Comoe river of South Burkina Faso, the biconical trap was mounted on a small wooden raft anchored to a stone, and catches were compared with the classical biconical trap put on the shores. G. p. gambiensis and G. tachinoides densities were not significantly different from those from the classical biconical one. The adaptations described here have allowed to efficiently catch tsetse on the water, which to our knowledge is reported here for the first time. This represents a great progress and opens new opportunities to undertake studies on the vectors of trypanosomoses in mangrove areas of Guinea, which are currently the areas showing the highest prevalences of sleeping sickness in West Africa. It also has huge potential for tsetse control using insecticide impregnated traps in savannah areas where traps become less efficient in rainy season. The Guinean National control programme has already expressed its willingness to use such modified traps in its control campaigns in Guinea, as has the national PATTEC programme in Burkina Faso during rainy season. PMID:21678789
Barnard, Annette-Christi; Nijhof, Ard M.; Fick, Wilma; Stutzer, Christian; Maritz-Olivier, Christine
2012-01-01
The availability of genome sequencing data in combination with knowledge of expressed genes via transcriptome and proteome data has greatly advanced our understanding of arthropod vectors of disease. Not only have we gained insight into vector biology, but also into their respective vector-pathogen interactions. By combining the strengths of postgenomic databases and reverse genetic approaches such as RNAi, the numbers of available drug and vaccine targets, as well as number of transgenes for subsequent transgenic or paratransgenic approaches, have expanded. These are now paving the way for in-field control strategies of vectors and their pathogens. Basic scientific questions, such as understanding the basic components of the vector RNAi machinery, is vital, as this allows for the transfer of basic RNAi machinery components into RNAi-deficient vectors, thereby expanding the genetic toolbox of these RNAi-deficient vectors and pathogens. In this review, we focus on the current knowledge of arthropod vector RNAi machinery and the impact of RNAi on understanding vector biology and vector-pathogen interactions for which vector genomic data is available on VectorBase. PMID:24705082
Optical implementation of inner product neural associative memory
NASA Technical Reports Server (NTRS)
Liu, Hua-Kuang (Inventor)
1995-01-01
An optical implementation of an inner-product neural associative memory is realized with a first spatial light modulator for entering an initial two-dimensional N-tuple vector and for entering a thresholded output vector image after each iteration until convergence is reached, and a second spatial light modulator for entering M weighted vectors of inner-product scalars multiplied with each of the M stored vectors, where the inner-product scalars are produced by multiplication of the initial input vector in the first iterative cycle (and thresholded vectors in subsequent iterative cycles) with each of the M stored vectors, and the weighted vectors are produced by multiplication of the scalars with corresponding ones of the stored vectors. A Hughes liquid crystal light valve is used for the dual function of summing the weighted vectors and thresholding the sum vector. The thresholded vector is then entered through the first spatial light modulator for reiteration of the process cycle until convergence is reached.
Vector nature of multi-soliton patterns in a passively mode-locked figure-eight fiber laser.
Ning, Qiu-Yi; Liu, Hao; Zheng, Xu-Wu; Yu, Wei; Luo, Ai-Ping; Huang, Xu-Guang; Luo, Zhi-Chao; Xu, Wen-Cheng; Xu, Shan-Hui; Yang, Zhong-Min
2014-05-19
The vector nature of multi-soliton dynamic patterns was investigated in a passively mode-locked figure-eight fiber laser based on the nonlinear amplifying loop mirror (NALM). By properly adjusting the cavity parameters such as the pump power level and intra-cavity polarization controllers (PCs), in addition to the fundamental vector soliton, various vector multi-soliton regimes were observed, such as the random static distribution of vector multiple solitons, vector soliton cluster, vector soliton flow, and the state of vector multiple solitons occupying the whole cavity. Both the polarization-locked vector solitons (PLVSs) and the polarization-rotating vector solitons (PRVSs) were observed for fundamental soliton and each type of multi-soliton patterns. The obtained results further reveal the fundamental physics of multi-soliton patterns and demonstrate that the figure-eight fiber lasers are indeed a good platform for investigating the vector nature of different soliton types.
Halbert, Christine L; Allen, James M; Miller, A Dusty
2002-07-01
The small packaging capacity of adeno-associated virus (AAV) vectors limits the utility of this promising vector system for transfer of large genes. We explored the possibility that larger genes could be reconstituted following homologous recombination between AAV vectors carrying overlapping gene fragments. An alkaline phosphatase (AP) gene was split between two such AAV vectors (rec vectors) and packaged using AAV2 or AAV6 capsid proteins. Rec vectors having either capsid protein recombined to express AP in cultured cells at about 1-2% of the rate observed for an intact vector. Surprisingly, the AAV6 rec vectors transduced lung cells in mice almost as efficiently as did an intact vector, with 10% of airway epithelial cells, the target for treatment of cystic fibrosis (CF), being positive. Thus AAV rec vectors may be useful for diseases such as CF that require transfer of large genes.
Method and system for operating an electric motor
Gallegos-Lopez, Gabriel; Hiti, Silva; Perisic, Milun
2013-01-22
Methods and systems for operating an electric motor having a plurality of windings with an inverter having a plurality of switches coupled to a voltage source are provided. A first plurality of switching vectors is applied to the plurality of switches. The first plurality of switching vectors includes a first ratio of first magnitude switching vectors to second magnitude switching vectors. A direct current (DC) current associated with the voltage source is monitored during the applying of the first plurality of switching vectors to the plurality of switches. A second ratio of the first magnitude switching vectors to the second magnitude switching vectors is selected based on the monitoring of the DC current associated with the voltage source. A second plurality of switching vectors is applied to the plurality of switches. The second plurality of switching vectors includes the second ratio of the first magnitude switching vectors to the second magnitude switching vectors.
Syngeneic AAV pseudo-vectors potentiates full vector transduction
USDA-ARS?s Scientific Manuscript database
An excessive amount of empty capsids are generated during regular AAV vector production process. These pseudo-vectors often remain in final vectors used for animal studies or clinical trials. The potential effects of these pseudo-vectors on AAV transduction have been a major concern. In the current ...
Herz, Stefan; Füssl, Monika; Steiger, Sandra; Koop, Hans-Ulrich
2005-12-01
Two new vector types for plastid transformation were developed and uidA reporter gene expression was compared to standard transformation vectors. The first vector type does not contain any plastid promoter, instead it relies on extension of existing plastid operons and was therefore named "operon-extension" vector. When a strongly expressed plastid operon like psbA was extended by the reporter gene with this vector type, the expression level was superior to that of a standard vector under control of the 16S rRNA promoter. Different insertion sites, promoters and 5'-UTRs were analysed for their effect on reporter gene expression with standard and operon-extension vectors. The 5'-UTR of phage 7 gene 10 in combination with a modified N-terminus was found to yield the highest expression levels. Expression levels were also strongly dependent on external factors like plant or leaf age or light intensity. In the second vector type, named "split" plastid transformation vector, modules of the expression cassette were distributed on two separate vectors. Upon co-transformation of plastids with these vectors, the complete expression cassette became inserted into the plastome. This result can be explained by successive co-integration of the split vectors and final loop-out recombination of the duplicated sequences. The split vector concept was validated with different vector pairs.
The ecological foundations of transmission potential and vector-borne disease in urban landscapes.
LaDeau, Shannon L; Allan, Brian F; Leisnham, Paul T; Levy, Michael Z
2015-07-01
Urban transmission of arthropod-vectored disease has increased in recent decades. Understanding and managing transmission potential in urban landscapes requires integration of sociological and ecological processes that regulate vector population dynamics, feeding behavior, and vector-pathogen interactions in these unique ecosystems. Vectorial capacity is a key metric for generating predictive understanding about transmission potential in systems with obligate vector transmission. This review evaluates how urban conditions, specifically habitat suitability and local temperature regimes, and the heterogeneity of urban landscapes can influence the biologically-relevant parameters that define vectorial capacity: vector density, survivorship, biting rate, extrinsic incubation period, and vector competence.Urban landscapes represent unique mosaics of habitat. Incidence of vector-borne disease in urban host populations is rarely, if ever, evenly distributed across an urban area. The persistence and quality of vector habitat can vary significantly across socio-economic boundaries to influence vector species composition and abundance, often generating socio-economically distinct gradients of transmission potential across neighborhoods.Urban regions often experience unique temperature regimes, broadly termed urban heat islands (UHI). Arthropod vectors are ectothermic organisms and their growth, survival, and behavior are highly sensitive to environmental temperatures. Vector response to UHI conditions is dependent on regional temperature profiles relative to the vector's thermal performance range. In temperate climates UHI can facilitate increased vector development rates while having countervailing influence on survival and feeding behavior. Understanding how urban heat island (UHI) conditions alter thermal and moisture constraints across the vector life cycle to influence transmission processes is an important direction for both empirical and modeling research.There remain persistent gaps in understanding of vital rates and drivers in mosquito-vectored disease systems, and vast holes in understanding for other arthropod vectored diseases. Empirical studies are needed to better understand the physiological constraints and socio-ecological processes that generate heterogeneity in critical transmission parameters, including vector survival and fitness. Likewise, laboratory experiments and transmission models must evaluate vector response to realistic field conditions, including variability in sociological and environmental conditions.
The Variation of Catalyst and Carrier Gas on Anisole Deoxygenation Reaction
NASA Astrophysics Data System (ADS)
Ariyani, D.; Dwi Nugrahaningtyas, Khoirina; Heraldy, E.
2018-03-01
This research aims to determine the best catalyst and carrier gas in anisole deoxygenation reaction. The reaction was carried out over a flow system with a variation of catalyst CoMo A (CoMo/USY reduction), CoMo B (CoMo/USY oxidation-reduction), and CoMo C (CoMo/ZAA oxidation-reduction). In addition, variation of carrier gas nitrogen and hydrogen was investigated. The result was analyzed using Gas Chromatography-Mass Spectroscopy (GC-MS). The deoxygenation anisole result showed that CoMo A catalyst with hydrogen as the carrier gas has the highest total product yield (50.72 %), intermediate product yield (38.49 % in phenol and 6.99 % in benzaldehyde), and deoxygenation yield (5.24 %). The CoMo C catalyst exhibited the most selective deoxygenation product. The nitrogen carrier gas with the CoMo C catalyst has the best selectivity of benzene product (93.92 %).
Palaniyandi, M
2012-12-01
There have been several attempts made to the appreciation of remote sensing and GIS for the study of vectors, biodiversity, vector presence, vector abundance and the vector-borne diseases with respect to space and time. This study was made for reviewing and appraising the potential use of remote sensing and GIS applications for spatial prediction of vector-borne diseases transmission. The nature of the presence and the abundance of vectors and vector-borne diseases, disease infection and the disease transmission are not ubiquitous and are confined with geographical, environmental and climatic factors, and are localized. The presence of vectors and vector-borne diseases is most complex in nature, however, it is confined and fueled by the geographical, climatic and environmental factors including man-made factors. The usefulness of the present day availability of the information derived from the satellite data including vegetation indices of canopy cover and its density, soil types, soil moisture, soil texture, soil depth, etc. is integrating the information in the expert GIS engine for the spatial analysis of other geoclimatic and geoenvironmental variables. The present study gives the detailed information on the classical studies of the past and present, and the future role of remote sensing and GIS for the vector-borne diseases control. The ecological modeling directly gives us the relevant information to understand the spatial variation of the vector biodiversity, vector presence, vector abundance and the vector-borne diseases in association with geoclimatic and the environmental variables. The probability map of the geographical distribution and seasonal variations of horizontal and vertical distribution of vector abundance and its association with vector -borne diseases can be obtained with low cost remote sensing and GIS tool with reliable data and speed.
A diagram for evaluating multiple aspects of model performance in simulating vector fields
NASA Astrophysics Data System (ADS)
Xu, Zhongfeng; Hou, Zhaolu; Han, Ying; Guo, Weidong
2016-12-01
Vector quantities, e.g., vector winds, play an extremely important role in climate systems. The energy and water exchanges between different regions are strongly dominated by wind, which in turn shapes the regional climate. Thus, how well climate models can simulate vector fields directly affects model performance in reproducing the nature of a regional climate. This paper devises a new diagram, termed the vector field evaluation (VFE) diagram, which is a generalized Taylor diagram and able to provide a concise evaluation of model performance in simulating vector fields. The diagram can measure how well two vector fields match each other in terms of three statistical variables, i.e., the vector similarity coefficient, root mean square length (RMSL), and root mean square vector difference (RMSVD). Similar to the Taylor diagram, the VFE diagram is especially useful for evaluating climate models. The pattern similarity of two vector fields is measured by a vector similarity coefficient (VSC) that is defined by the arithmetic mean of the inner product of normalized vector pairs. Examples are provided, showing that VSC can identify how close one vector field resembles another. Note that VSC can only describe the pattern similarity, and it does not reflect the systematic difference in the mean vector length between two vector fields. To measure the vector length, RMSL is included in the diagram. The third variable, RMSVD, is used to identify the magnitude of the overall difference between two vector fields. Examples show that the VFE diagram can clearly illustrate the extent to which the overall RMSVD is attributed to the systematic difference in RMSL and how much is due to the poor pattern similarity.
Thyra Abstract Interface Package
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlett, Roscoe A.
2005-09-01
Thrya primarily defines a set of abstract C++ class interfaces needed for the development of abstract numerical atgorithms (ANAs) such as iterative linear solvers, transient solvers all the way up to optimization. At the foundation of these interfaces are abstract C++ classes for vectors, vector spaces, linear operators and multi-vectors. Also included in the Thyra package is C++ code for creating concrete vector, vector space, linear operator, and multi-vector subclasses as well as other utilities to aid in the development of ANAs. Currently, very general and efficient concrete subclass implementations exist for serial and SPMD in-core vectors and multi-vectors. Codemore » also currently exists for testing objects and providing composite objects such as product vectors.« less
Vector 33: A reduce program for vector algebra and calculus in orthogonal curvilinear coordinates
NASA Astrophysics Data System (ADS)
Harper, David
1989-06-01
This paper describes a package with enables REDUCE 3.3 to perform algebra and calculus operations upon vectors. Basic algebraic operations between vectors and between scalars and vectors are provided, including scalar (dot) product and vector (cross) product. The vector differential operators curl, divergence, gradient and Laplacian are also defined, and are valid in any orthogonal curvilinear coordinate system. The package is written in RLISP to allow algebra and calculus to be performed using notation identical to that for operations. Scalars and vectors can be mixed quite freely in the same expression. The package will be of interest to mathematicians, engineers and scientists who need to perform vector calculations in orthogonal curvilinear coordinates.
Current Advances and Future Challenges in Adenoviral Vector Biology and Targeting
Campos, Samuel K.; Barry, Michael A.
2008-01-01
Gene delivery vectors based on Adenoviral (Ad) vectors have enormous potential for the treatment of both hereditary and acquired disease. Detailed structural analysis of the Ad virion, combined with functional studies has broadened our knowledge of the structure/function relationships between Ad vectors and host cells/tissues and substantial achievement has been made towards a thorough understanding of the biology of Ad vectors. The widespread use of Ad vectors for clinical gene therapy is compromised by their inherent immunogenicity. The generation of safer and more effective Ad vectors, targeted to the site of disease, has therefore become a great ambition in the field of Ad vector development. This review provides a synopsis of the structure/function relationships between Ad vectors and host systems and summarizes the many innovative approaches towards achieving Ad vector targeting. PMID:17584037
Elliptic-symmetry vector optical fields.
Pan, Yue; Li, Yongnan; Li, Si-Min; Ren, Zhi-Cheng; Kong, Ling-Jun; Tu, Chenghou; Wang, Hui-Tian
2014-08-11
We present in principle and demonstrate experimentally a new kind of vector fields: elliptic-symmetry vector optical fields. This is a significant development in vector fields, as this breaks the cylindrical symmetry and enriches the family of vector fields. Due to the presence of an additional degrees of freedom, which is the interval between the foci in the elliptic coordinate system, the elliptic-symmetry vector fields are more flexible than the cylindrical vector fields for controlling the spatial structure of polarization and for engineering the focusing fields. The elliptic-symmetry vector fields can find many specific applications from optical trapping to optical machining and so on.
Kinematic sensitivity of robot manipulators
NASA Technical Reports Server (NTRS)
Vuskovic, Marko I.
1989-01-01
Kinematic sensitivity vectors and matrices for open-loop, n degrees-of-freedom manipulators are derived. First-order sensitivity vectors are defined as partial derivatives of the manipulator's position and orientation with respect to its geometrical parameters. The four-parameter kinematic model is considered, as well as the five-parameter model in case of nominally parallel joint axes. Sensitivity vectors are expressed in terms of coordinate axes of manipulator frames. Second-order sensitivity vectors, the partial derivatives of first-order sensitivity vectors, are also considered. It is shown that second-order sensitivity vectors can be expressed as vector products of the first-order sensitivity vectors.
Genetic variation in arthropod vectors of disease-causing organisms: obstacles and opportunities.
Gooding, R H
1996-01-01
An overview of the genetic variation in arthropods that transmit pathogens to vertebrates is presented, emphasizing the genetics of vector-pathogen relationships and the biochemical genetics of vectors. Vector-pathogen interactions are reviewed briefly as a prelude to a discussion of the genetics of susceptibility and refractoriness in vectors. Susceptibility to pathogens is controlled by maternally inherited factors, sex-linked dominant alleles, and dominant and recessive autosomal genes. There is widespread interpopulation (including intercolony) and temporal variation in susceptibility to pathogens. The amount of biochemical genetic variation in vectors is similar to that found in other invertebrates. However, the amount varies widely among species, among populations within species, and temporally within populations. Biochemical genetic studies show that there is considerable genetic structuring of many vectors at the local, regional, and global levels. It is argued that genetic variation in vectors is critical in understanding vector-pathogen interactions and that genetic variation in vectors creates both obstacles to and opportunities for application of genetic techniques to the control of vectors. PMID:8809462
A Subdivision-Based Representation for Vector Image Editing.
Liao, Zicheng; Hoppe, Hugues; Forsyth, David; Yu, Yizhou
2012-11-01
Vector graphics has been employed in a wide variety of applications due to its scalability and editability. Editability is a high priority for artists and designers who wish to produce vector-based graphical content with user interaction. In this paper, we introduce a new vector image representation based on piecewise smooth subdivision surfaces, which is a simple, unified and flexible framework that supports a variety of operations, including shape editing, color editing, image stylization, and vector image processing. These operations effectively create novel vector graphics by reusing and altering existing image vectorization results. Because image vectorization yields an abstraction of the original raster image, controlling the level of detail of this abstraction is highly desirable. To this end, we design a feature-oriented vector image pyramid that offers multiple levels of abstraction simultaneously. Our new vector image representation can be rasterized efficiently using GPU-accelerated subdivision. Experiments indicate that our vector image representation achieves high visual quality and better supports editing operations than existing representations.
Chromosomal integration of adenoviral vector DNA in vivo.
Stephen, Sam Laurel; Montini, Eugenio; Sivanandam, Vijayshankar Ganesh; Al-Dhalimy, Muhseen; Kestler, Hans A; Finegold, Milton; Grompe, Markus; Kochanek, Stefan
2010-10-01
So far there has been no report of any clinical or preclinical evidence for chromosomal vector integration following adenovirus (Ad) vector-mediated gene transfer in vivo. We used liver gene transfer with high-capacity Ad vectors in the FAH(Deltaexon5) mouse model to analyze homologous and heterologous recombination events between vector and chromosomal DNA. Intravenous injection of Ad vectors either expressing a fumarylacetoacetate hydrolase (FAH) cDNA or carrying part of the FAH genomic locus resulted in liver nodules of FAH-expressing hepatocytes, demonstrating chromosomal vector integration. Analysis of junctions between vector and chromosomal DNA following heterologous recombination indicated integration of the vector genome through its termini. Heterologous recombination occurred with a median frequency of 6.72 x 10(-5) per transduced hepatocyte, while homologous recombination occurred more rarely with a median frequency of 3.88 x 10(-7). This study has established quantitative and qualitative data on recombination of adenoviral vector DNA with genomic DNA in vivo, contributing to a risk-benefit assessment of the biosafety of Ad vector-mediated gene transfer.
Adenoviral Vector Immunity: Its Implications and circumvention strategies
Ahi, Yadvinder S.; Bangari, Dinesh S.; Mittal, Suresh K.
2014-01-01
Adenoviral (Ad) vectors have emerged as a promising gene delivery platform for a variety of therapeutic and vaccine purposes during last two decades. However, the presence of preexisting Ad immunity and the rapid development of Ad vector immunity still pose significant challenges to the clinical use of these vectors. Innate inflammatory response following Ad vector administration may lead to systemic toxicity, drastically limit vector transduction efficiency and significantly abbreviate the duration of transgene expression. Currently, a number of approaches are being extensively pursued to overcome these drawbacks by strategies that target either the host or the Ad vector. In addition, significant progress has been made in the development of novel Ad vectors based on less prevalent human Ad serotypes and nonhuman Ad. This review provides an update on our current understanding of immune responses to Ad vectors and delineates various approaches for eluding Ad vector immunity. Approaches targeting the host and those targeting the vector are discussed in light of their promises and limitations. PMID:21453277
Siapati, Elena K; Bigger, Brian W; Miskin, James; Chipchase, Daniel; Parsley, Kathryn L; Mitrophanous, Kyriacos; Themis, Mike; Thrasher, Adrian J; Bonnet, Dominique
2005-09-01
The use of lentiviral vectors for gene transfer into hematopoietic stem cells has raised considerable interest as these vectors can permanently integrate their genome into quiescent cells. Vectors based on alternative lentiviruses would theoretically be safer than HIV-1-based vectors and could also be used in HIV-positive patients, minimizing the risk of generating replication-competent virus. Here we report the use of third-generation equine infectious anemia virus (EIAV)- and HIV-1-based vectors with minimal viral sequences and absence of accessory proteins. We have compared their efficiency in transducing mouse and human hematopoietic stem cells both in vitro and in vivo to that of a previously documented second-generation HIV-1 vector. The third-generation EIAV- and HIV-based vectors gave comparable levels of transduction and transgene expression in both mouse and human NOD/SCID repopulating cells but were less efficient than the second-generation HIV-1 vector in human HSCs. For the EIAV vector this is possibly a reflection of the lower protein expression levels achieved in human cells, as vector copy number analysis revealed that this vector exhibited a trend to integrate equally efficiently compared to the third-generation HIV-1 vector in both mouse and human HSCs. Interestingly, the presence or absence of Tat in viral preparations did not influence the transduction efficiency of HIV-1 vectors in human HSCs.
Harmon, Andrew W.; Moitra, Rituparna; Xu, Zhili
2018-01-01
Adenovirus vectors are widely used in gene therapy clinical trials, and preclinical studies with these vectors are often conducted in mice. It is therefore critical to understand whether mouse studies adequately predict the behavior of adenovirus vectors in humans. The most commonly-used adenovirus vectors are derived from adenovirus serotype 5 (Ad5). The Ad5 hexon protein can bind coagulation factor X (FX), and binding of FX has a major impact on vector interactions with other blood proteins. In mouse serum, FX protects Ad5 vectors from neutralization by natural antibodies and complement. In the current study, we similarly find that human FX inhibits neutralization of Ad5 vectors by human serum, and this finding is consistent among individual human sera. We show that human IgM and human IgG can each induce complement-mediated neutralization when Ad5 vectors are not protected by FX. Although mouse and human serum had similar effects on Ad5 vectors, we found that this was not true for a chimeric Ad5 vector that incorporated hexon regions from adenovirus serotype 48. Interestingly, this hexon-chimeric vector was neutralized by human serum, but not by mouse serum. These findings indicate that studies in mouse serum accurately predict the behavior of Ad5 vectors in human serum, but mouse serum is not an accurate model system for all adenovirus vectors. PMID:29401488
Iso-vector form factors of the delta and nucleon in QCD sum rules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozpineci, A.
Form factors are important non-perturbative properties of hadrons. They give information about the internal structure of the hadrons. In this work, iso-vector axial-vector and iso-vector tensor form factors of the nucleon and the iso-vector axial-vector {Delta}{yields}N transition form factor calculations in QCD Sum Rules are presented.
Orthogonal vector algorithm to obtain the solar vector using the single-scattering Rayleigh model.
Wang, Yinlong; Chu, Jinkui; Zhang, Ran; Shi, Chao
2018-02-01
Information obtained from a polarization pattern in the sky provides many animals like insects and birds with vital long-distance navigation cues. The solar vector can be derived from the polarization pattern using the single-scattering Rayleigh model. In this paper, an orthogonal vector algorithm, which utilizes the redundancy of the single-scattering Rayleigh model, is proposed. We use the intersection angles between the polarization vectors as the main criteria in our algorithm. The assumption that all polarization vectors can be considered coplanar is used to simplify the three-dimensional (3D) problem with respect to the polarization vectors in our simulation. The surface-normal vector of the plane, which is determined by the polarization vectors after translation, represents the solar vector. Unfortunately, the two-directionality of the polarization vectors makes the resulting solar vector ambiguous. One important result of this study is, however, that this apparent disadvantage has no effect on the complexity of the algorithm. Furthermore, two other universal least-squares algorithms were investigated and compared. A device was then constructed, which consists of five polarized-light sensors as well as a 3D attitude sensor. Both the simulation and experimental data indicate that the orthogonal vector algorithms, if used with a suitable threshold, perform equally well or better than the other two algorithms. Our experimental data reveal that if the intersection angles between the polarization vectors are close to 90°, the solar-vector angle deviations are small. The data also support the assumption of coplanarity. During the 51 min experiment, the mean of the measured solar-vector angle deviations was about 0.242°, as predicted by our theoretical model.
Browning, Diana L.; Collins, Casey P.; Hocum, Jonah D.; Leap, David J.; Rae, Dustin T.; Trobridge, Grant D.
2016-01-01
Retroviral vector-mediated gene therapy is promising, but genotoxicity has limited its use in the clinic. Genotoxicity is highly dependent on the retroviral vector used, and foamy viral (FV) vectors appear relatively safe. However, internal promoters may still potentially activate nearby genes. We developed insulated FV vectors, using four previously described insulators: a version of the well-studied chicken hypersensitivity site 4 insulator (650cHS4), two synthetic CCCTC-binding factor (CTCF)-based insulators, and an insulator based on the CCAAT box-binding transcription factor/nuclear factor I (7xCTF/NF1). We directly compared these insulators for enhancer-blocking activity, effect on FV vector titer, and fidelity of transfer to both proviral long terminal repeats. The synthetic CTCF-based insulators had the strongest insulating activity, but reduced titers significantly. The 7xCTF/NF1 insulator did not reduce titers but had weak insulating activity. The 650cHS4-insulated FV vector was identified as the overall most promising vector. Uninsulated and 650cHS4-insulated FV vectors were both significantly less genotoxic than gammaretroviral vectors. Integration sites were evaluated in cord blood CD34+ cells and the 650cHS4-insulated FV vector had fewer hotspots compared with an uninsulated FV vector. These data suggest that insulated FV vectors are promising for hematopoietic stem cell gene therapy. PMID:26715244
Construction and Evaluation of Novel Rhesus Monkey Adenovirus Vaccine Vectors
Abbink, Peter; Maxfield, Lori F.; Ng'ang'a, David; Borducchi, Erica N.; Iampietro, M. Justin; Bricault, Christine A.; Teigler, Jeffrey E.; Blackmore, Stephen; Parenteau, Lily; Wagh, Kshitij; Handley, Scott A.; Zhao, Guoyan; Virgin, Herbert W.; Korber, Bette
2014-01-01
ABSTRACT Adenovirus vectors are widely used as vaccine candidates for a variety of pathogens, including HIV-1. To date, human and chimpanzee adenoviruses have been explored in detail as vaccine vectors. The phylogeny of human and chimpanzee adenoviruses is overlapping, and preexisting humoral and cellular immunity to both are exhibited in human populations worldwide. More distantly related adenoviruses may therefore offer advantages as vaccine vectors. Here we describe the primary isolation and vectorization of three novel adenoviruses from rhesus monkeys. The seroprevalence of these novel rhesus monkey adenovirus vectors was extremely low in sub-Saharan Africa human populations, and these vectors proved to have immunogenicity comparable to that of human and chimpanzee adenovirus vaccine vectors in mice. These rhesus monkey adenoviruses phylogenetically clustered with the poorly described adenovirus species G and robustly stimulated innate immune responses. These novel adenoviruses represent a new class of candidate vaccine vectors. IMPORTANCE Although there have been substantial efforts in the development of vaccine vectors from human and chimpanzee adenoviruses, far less is known about rhesus monkey adenoviruses. In this report, we describe the isolation and vectorization of three novel rhesus monkey adenoviruses. These vectors exhibit virologic and immunologic characteristics that make them attractive as potential candidate vaccine vectors for both HIV-1 and other pathogens. PMID:25410856
Construction and evaluation of novel rhesus monkey adenovirus vaccine vectors.
Abbink, Peter; Maxfield, Lori F; Ng'ang'a, David; Borducchi, Erica N; Iampietro, M Justin; Bricault, Christine A; Teigler, Jeffrey E; Blackmore, Stephen; Parenteau, Lily; Wagh, Kshitij; Handley, Scott A; Zhao, Guoyan; Virgin, Herbert W; Korber, Bette; Barouch, Dan H
2015-02-01
Adenovirus vectors are widely used as vaccine candidates for a variety of pathogens, including HIV-1. To date, human and chimpanzee adenoviruses have been explored in detail as vaccine vectors. The phylogeny of human and chimpanzee adenoviruses is overlapping, and preexisting humoral and cellular immunity to both are exhibited in human populations worldwide. More distantly related adenoviruses may therefore offer advantages as vaccine vectors. Here we describe the primary isolation and vectorization of three novel adenoviruses from rhesus monkeys. The seroprevalence of these novel rhesus monkey adenovirus vectors was extremely low in sub-Saharan Africa human populations, and these vectors proved to have immunogenicity comparable to that of human and chimpanzee adenovirus vaccine vectors in mice. These rhesus monkey adenoviruses phylogenetically clustered with the poorly described adenovirus species G and robustly stimulated innate immune responses. These novel adenoviruses represent a new class of candidate vaccine vectors. Although there have been substantial efforts in the development of vaccine vectors from human and chimpanzee adenoviruses, far less is known about rhesus monkey adenoviruses. In this report, we describe the isolation and vectorization of three novel rhesus monkey adenoviruses. These vectors exhibit virologic and immunologic characteristics that make them attractive as potential candidate vaccine vectors for both HIV-1 and other pathogens. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Vector Addition: Effect of the Context and Position of the Vectors
NASA Astrophysics Data System (ADS)
Barniol, Pablo; Zavala, Genaro
2010-10-01
In this article we investigate the effect of: 1) the context, and 2) the position of the vectors, on 2D vector addition tasks. We administered a test to 512 students completing introductory physics courses at a private Mexican university. In the first part, we analyze students' responses in three isomorphic problems: displacements, forces, and no physical context. Students were asked to draw two vectors and the vector sum. We analyzed students' procedures detecting the difficulties when drawing the vector addition and proved that the context matters, not only compared to the context-free case but also between the contexts. In the second part, we analyze students' responses with three different arrangements of the sum of two vectors: tail-to-tail, head-to-tail and separated vectors. We compared the frequencies of the errors in the three different positions to deduce students' conceptions in the addition of vectors.
Vectors and Rotations in 3-Dimensions: Vector Algebra for the C++ Programmer
2016-12-01
Proving Ground, MD 21005-5068 This report describes 2 C++ classes: a Vector class for performing vector algebra in 3-dimensional space ( 3D ) and a Rotation...class for performing rotations of vectors in 3D . Each class is self-contained in a single header file (Vector.h and Rotation.h) so that a C...vector, rotation, 3D , quaternion, C++ tools, rotation sequence, Euler angles, yaw, pitch, roll, orientation 98 Richard Saucier 410-278-6721Unclassified
NASA Technical Reports Server (NTRS)
Asbury, Scott C.
1993-01-01
An investigation was conducted in the static test facility of the Langley 16-Foot Transonic Tunnel to evaluate the internal performance of a nonaxisymmetric convergent divergent nozzle designed to have simultaneous pitch and yaw thrust vectoring capability. This concept utilized divergent flap deflection for thrust vectoring in the pitch plane and flow-turning deflectors installed within the divergent flaps for yaw thrust vectoring. Modifications consisting of reducing the sidewall length and deflecting the sidewall outboard were investigated as means to increase yaw-vectoring performance. This investigation studied the effects of multiaxis (pitch and yaw) thrust vectoring on nozzle internal performance characteristics. All tests were conducted with no external flow, and nozzle pressure ratio was varied from 2.0 to approximately 13.0. The results indicate that this nozzle concept can successfully generate multiaxis thrust vectoring. Deflection of the divergent flaps produced resultant pitch vector angles that, although dependent on nozzle pressure ratio, were nearly equal to the geometric pitch vector angle. Losses in resultant thrust due to pitch vectoring were small or negligible. The yaw deflectors produced resultant yaw vector angles up to 21 degrees that were controllable by varying yaw deflector rotation. However, yaw deflector rotation resulted in significant losses in thrust ratios and, in some cases, nozzle discharge coefficient. Either of the sidewall modifications generally reduced these losses and increased maximum resultant yaw vector angle. During multiaxis (simultaneous pitch and yaw) thrust vectoring, little or no cross coupling between the thrust vectoring processes was observed.
VectorBase: a data resource for invertebrate vector genomics
Lawson, Daniel; Arensburger, Peter; Atkinson, Peter; Besansky, Nora J.; Bruggner, Robert V.; Butler, Ryan; Campbell, Kathryn S.; Christophides, George K.; Christley, Scott; Dialynas, Emmanuel; Hammond, Martin; Hill, Catherine A.; Konopinski, Nathan; Lobo, Neil F.; MacCallum, Robert M.; Madey, Greg; Megy, Karine; Meyer, Jason; Redmond, Seth; Severson, David W.; Stinson, Eric O.; Topalis, Pantelis; Birney, Ewan; Gelbart, William M.; Kafatos, Fotis C.; Louis, Christos; Collins, Frank H.
2009-01-01
VectorBase (http://www.vectorbase.org) is an NIAID-funded Bioinformatic Resource Center focused on invertebrate vectors of human pathogens. VectorBase annotates and curates vector genomes providing a web accessible integrated resource for the research community. Currently, VectorBase contains genome information for three mosquito species: Aedes aegypti, Anopheles gambiae and Culex quinquefasciatus, a body louse Pediculus humanus and a tick species Ixodes scapularis. Since our last report VectorBase has initiated a community annotation system, a microarray and gene expression repository and controlled vocabularies for anatomy and insecticide resistance. We have continued to develop both the software infrastructure and tools for interrogating the stored data. PMID:19028744
Production, concentration and titration of pseudotyped HIV-1-based lentiviral vectors.
Kutner, Robert H; Zhang, Xian-Yang; Reiser, Jakob
2009-01-01
Over the past decade, lentiviral vectors have emerged as powerful tools for transgene delivery. The use of lentiviral vectors has become commonplace and applications in the fields of neuroscience, hematology, developmental biology, stem cell biology and transgenesis are rapidly emerging. Also, lentiviral vectors are at present being explored in the context of human clinical trials. Here we describe improved protocols to generate highly concentrated lentiviral vector pseudotypes involving different envelope glycoproteins. In this protocol, vector stocks are prepared by transient transfection using standard cell culture media or serum-free media. Such stocks are then concentrated by ultracentrifugation and/or ion exchange chromatography, or by precipitation using polyethylene glycol 6000, resulting in vector titers of up to 10(10) transducing units per milliliter and above. We also provide reliable real-time PCR protocols to titrate lentiviral vectors based on proviral DNA copies present in genomic DNA extracted from transduced cells or on vector RNA. These production/concentration methods result in high-titer vector preparations that show reduced toxicity compared with lentiviral vectors produced using standard protocols involving ultracentrifugation-based methods. The vector production and titration protocol described here can be completed within 8 d.
Helper-Free Foamy Virus Vectors
TROBRIDGE, GRANT D.; RUSSELL, DAVID W.
2010-01-01
Retroviral vectors based on human foamy virus (HFV) have been developed and show promise as gene therapy vehicles. Here we describe a method for the production of HFV vector stocks free of detectable helper virus. The helper and vector plasmid constructs used both lack the HFV bel genes, so recombination between these constructs cannot create a wild-type virus. A fusion promoter that combines portions of the cytomegalovirus (CMV) immediate-early and HFV long terminal repeat (LTR) promoters was used to drive expression of both the helper and vector constructs. The CMV–LTR fusion promoter allows for HFV vector production in the absence of the Bel-1 trans-activator protein, which would otherwise be necessary for efficient transcription from the HFV LTR. Vector stocks containing either neomycin phosphotransferase or alkaline phosphatase reporter genes were produced by transient transfection at titers greater than 105 transducing units/ml. G418-resistant BHK-21 cells obtained by transduction with neo vectors contained randomly integrated HFV vector proviruses without detectable deletions or rearrangements. The vector stocks generated were free of replication-competent retrovirus (RCR), as determined by assays for LTR trans-activation and a marker rescue assay developed here for the detection of Bel-independent RCR. OVERVIEW SUMMARY Vectors based on human foamy virus have been developed but low titers and the presence of replication-competent retrovirus (RCR) in vector stocks have prevented their use in preclinical animal experiments. We have developed a transient transfection method that can be used to produce replication-incompetent HFV vector stocks at titers greater than 105/ml, and that does not produce contaminating RCR. The use of CMV-HFV LTR fusion promoters in the helper and vector constructs has circumvented the requirement for the HFV Bel-1 trans-activator protein. Consequently, the potential for generating wild-type HFV by recombination between helper and vector constructs during vector production has been eliminated. Here we describe HFV vector production using this Bel-independent system. PMID:9853518
Halbert, Christine L.; Rutledge, Elizabeth A.; Allen, James M.; Russell, David W.; Miller, A. Dusty
2000-01-01
Vectors derived from adeno-associated virus type 2 (AAV2) promote gene transfer and expression in the lung; however, we have found that while gene expression can persist for at least 8 months in mice, it was reduced dramatically in rabbits over a period of 2 months. The efficiency and persistence of AAV2-mediated gene expression in the human lung have yet to be determined, but it seems likely that readministration will be necessary over the lifetime of an individual. Unfortunately, we have found that transduction by a second administration of an AAV2 vector is blocked, presumably due to neutralizing antibodies generated in response to the primary vector exposure. Here, we have explored the use of AAV2 vectors pseudotyped with capsid proteins from AAV serotypes 2, 3, and 6 for readministration in the mouse lung. We found that an AAV6 vector transduced airway epithelial and alveolar cells in the lung at rates that were at least as high as those of AAV2 pseudotype vectors, while transduction rates mediated by AAV3 were much lower. AAV6 pseudotype vector transduction was unaffected by prior administration of an AAV2 or AAV3 vector, and transduction by an AAV2 pseudotype vector was unaffected by prior AAV6 vector administration, showing that cross-reactive neutralizing antibodies against AAV2 and AAV6 are not generated in mice. Interestingly, while prior administration of an AAV2 vector completely blocked transduction by a second AAV2 pseudotype vector, prior administration of an AAV6 vector only partially inhibited transduction by a second administration of an AAV6 pseudotype vector. Analysis of sera obtained from mice and humans showed that AAV6 is less immunogenic than AAV2, which helps explain this finding. These results support the development of AAV6 vectors for lung gene therapy both alone and in combination with AAV2 vectors. PMID:10627564
Calderone, G.J.; Butler, R.F.
1991-01-01
Random tilting of a single paleomagnetic vector produces a distribution of vectors which is not rotationally symmetric about the original vector and therefore not Fisherian. Monte Carlo simulations were performed on two types of vector distributions: 1) distributions of vectors formed by perturbing a single original vector with a Fisher distribution of bedding poles (each defining a tilt correction) and 2) standard Fisher distributions. These simulations demonstrate that inclinations of vectors drawn from both distributions are biased toward shallow inclinations. The Fisher mean direction of the distribution of vectors formed by perturbing a single vector with random undetected tilts is biased toward shallow inclinations, but this bias is insignificant for angular dispersions of bedding poles less than 20??. -from Authors
The application of vector concepts on two skew lines
NASA Astrophysics Data System (ADS)
Alghadari, F.; Turmudi; Herman, T.
2018-01-01
The purpose of this study is knowing how to apply vector concepts on two skew lines in three-dimensional (3D) coordinate and its utilization. Several mathematical concepts have a related function for the other, but the related between the concept of vector and 3D have not applied in learning classroom. In fact, there are studies show that female students have difficulties in learning of 3D than male. It is because of personal spatial intelligence. The relevance of vector concepts creates both learning achievement and mathematical ability of male and female students enables to be balanced. The distance like on a cube, cuboid, or pyramid whose are drawn on the rectangular coordinates of a point in space. Two coordinate points of the lines can be created a vector. The vector of two skew lines has the shortest distance and the angle. Calculating of the shortest distance is started to create two vectors as a representation of line by vector position concept, next to determining a norm-vector of two vector which was obtained by cross-product, and then to create a vector from two combination of pair-points which was passed by two skew line, the shortest distance is scalar orthogonal projection of norm-vector on a vector which is a combination of pair-points. While calculating the angle are used two vectors as a representation of line to dot-product, and the inverse of cosine is yield. The utilization of its application on mathematics learning and orthographic projection method.
Condit, Richard C.; Williamson, Anna-Lise; Sheets, Rebecca; Seligman, Stephen J.; Monath, Thomas P.; Excler, Jean-Louis; Gurwith, Marc; Bok, Karin; Robertson, James S.; Kim, Denny; Hendry, Michael; Singh, Vidisha; Mac, Lisa M.; Chen, Robert T.
2016-01-01
In 2003 and 2013, the World Health Organization convened informal consultations on characterization and quality aspects of vaccines based on live virus vectors. In the resulting reports, one of several issues raised for future study was the potential for recombination of virus-vectored vaccines with wild type pathogenic virus strains. This paper presents an assessment of this issue formulated by the Brighton Collaboration. To provide an appropriate context for understanding the potential for recombination of virus-vectored vaccines, we review briefly the current status of virus vectored vaccines, mechanisms of recombination between viruses, experience with recombination involving live attenuated vaccines in the field, and concerns raised previously in the literature regarding recombination of virus-vectored vaccines with wild type virus strains. We then present a discussion of the major variables that could influence recombination between a virus-vectored vaccine and circulating wild type virus and the consequences of such recombination, including intrinsic recombination properties of the parent virus used as a vector; sequence relatedness of vector and wild virus; virus host range, pathogenesis and transmission; replication competency of vector in target host; mechanism of vector attenuation; additional factors potentially affecting virulence; and circulation of multiple recombinant vectors in the same target population. Finally, we present some guiding principles for vector design and testing intended to anticipate and mitigate the potential for and consequences of recombination of virus-vectored vaccines with wild type pathogenic virus strains. PMID:27346303
NASA Astrophysics Data System (ADS)
Li, Hui; Hong, Lu-Yao; Zhou, Qing; Yu, Hai-Jie
2015-08-01
The business failure of numerous companies results in financial crises. The high social costs associated with such crises have made people to search for effective tools for business risk prediction, among which, support vector machine is very effective. Several modelling means, including single-technique modelling, hybrid modelling, and ensemble modelling, have been suggested in forecasting business risk with support vector machine. However, existing literature seldom focuses on the general modelling frame for business risk prediction, and seldom investigates performance differences among different modelling means. We reviewed researches on forecasting business risk with support vector machine, proposed the general assisted prediction modelling frame with hybridisation and ensemble (APMF-WHAE), and finally, investigated the use of principal components analysis, support vector machine, random sampling, and group decision, under the general frame in forecasting business risk. Under the APMF-WHAE frame with support vector machine as the base predictive model, four specific predictive models were produced, namely, pure support vector machine, a hybrid support vector machine involved with principal components analysis, a support vector machine ensemble involved with random sampling and group decision, and an ensemble of hybrid support vector machine using group decision to integrate various hybrid support vector machines on variables produced from principle components analysis and samples from random sampling. The experimental results indicate that hybrid support vector machine and ensemble of hybrid support vector machines were able to produce dominating performance than pure support vector machine and support vector machine ensemble.
Learning with LOGO: Logo and Vectors.
ERIC Educational Resources Information Center
Lough, Tom; Tipps, Steve
1986-01-01
This is the first of a two-part series on the general concept of vector space. Provides tool procedures to allow investigation of vector properties, vector addition and subtraction, and X and Y components. Lists several sources of additional vector ideas. (JM)
The Design of a Templated C++ Small Vector Class for Numerical Computing
NASA Technical Reports Server (NTRS)
Moran, Patrick J.
2000-01-01
We describe the design and implementation of a templated C++ class for vectors. The vector class is templated both for vector length and vector component type; the vector length is fixed at template instantiation time. The vector implementation is such that for a vector of N components of type T, the total number of bytes required by the vector is equal to N * size of (T), where size of is the built-in C operator. The property of having a size no bigger than that required by the components themselves is key in many numerical computing applications, where one may allocate very large arrays of small, fixed-length vectors. In addition to the design trade-offs motivating our fixed-length vector design choice, we review some of the C++ template features essential to an efficient, succinct implementation. In particular, we highlight some of the standard C++ features, such as partial template specialization, that are not supported by all compilers currently. This report provides an inventory listing the relevant support currently provided by some key compilers, as well as test code one can use to verify compiler capabilities.
USDA-ARS?s Scientific Manuscript database
Genetic variability in insect vectors is valuable to study vector competence determinants and to select non-vector populations that may help reduce the spread of vector-borne pathogens. We collected and tested vector competency of 15 isofemale lines of Asian citrus psyllid (ACP) Diaphorina citri, v...
Abad-Franch, Fernando; Valença-Barbosa, Carolina; Sarquis, Otília; Lima, Marli M.
2014-01-01
Background Vector-borne diseases are major public health concerns worldwide. For many of them, vector control is still key to primary prevention, with control actions planned and evaluated using vector occurrence records. Yet vectors can be difficult to detect, and vector occurrence indices will be biased whenever spurious detection/non-detection records arise during surveys. Here, we investigate the process of Chagas disease vector detection, assessing the performance of the surveillance method used in most control programs – active triatomine-bug searches by trained health agents. Methodology/Principal Findings Control agents conducted triplicate vector searches in 414 man-made ecotopes of two rural localities. Ecotope-specific ‘detection histories’ (vectors or their traces detected or not in each individual search) were analyzed using ordinary methods that disregard detection failures and multiple detection-state site-occupancy models that accommodate false-negative and false-positive detections. Mean (±SE) vector-search sensitivity was ∼0.283±0.057. Vector-detection odds increased as bug colonies grew denser, and were lower in houses than in most peridomestic structures, particularly woodpiles. False-positive detections (non-vector fecal streaks misidentified as signs of vector presence) occurred with probability ∼0.011±0.008. The model-averaged estimate of infestation (44.5±6.4%) was ∼2.4–3.9 times higher than naïve indices computed assuming perfect detection after single vector searches (11.4–18.8%); about 106–137 infestation foci went undetected during such standard searches. Conclusions/Significance We illustrate a relatively straightforward approach to addressing vector detection uncertainty under realistic field survey conditions. Standard vector searches had low sensitivity except in certain singular circumstances. Our findings suggest that many infestation foci may go undetected during routine surveys, especially when vector density is low. Undetected foci can cause control failures and induce bias in entomological indices; this may confound disease risk assessment and mislead program managers into flawed decision making. By helping correct bias in naïve indices, the approach we illustrate has potential to critically strengthen vector-borne disease control-surveillance systems. PMID:25233352
Balancing aggregation and smoothing errors in inverse models
Turner, A. J.; Jacob, D. J.
2015-06-30
Inverse models use observations of a system (observation vector) to quantify the variables driving that system (state vector) by statistical optimization. When the observation vector is large, such as with satellite data, selecting a suitable dimension for the state vector is a challenge. A state vector that is too large cannot be effectively constrained by the observations, leading to smoothing error. However, reducing the dimension of the state vector leads to aggregation error as prior relationships between state vector elements are imposed rather than optimized. Here we present a method for quantifying aggregation and smoothing errors as a function ofmore » state vector dimension, so that a suitable dimension can be selected by minimizing the combined error. Reducing the state vector within the aggregation error constraints can have the added advantage of enabling analytical solution to the inverse problem with full error characterization. We compare three methods for reducing the dimension of the state vector from its native resolution: (1) merging adjacent elements (grid coarsening), (2) clustering with principal component analysis (PCA), and (3) applying a Gaussian mixture model (GMM) with Gaussian pdfs as state vector elements on which the native-resolution state vector elements are projected using radial basis functions (RBFs). The GMM method leads to somewhat lower aggregation error than the other methods, but more importantly it retains resolution of major local features in the state vector while smoothing weak and broad features.« less
Balancing aggregation and smoothing errors in inverse models
NASA Astrophysics Data System (ADS)
Turner, A. J.; Jacob, D. J.
2015-01-01
Inverse models use observations of a system (observation vector) to quantify the variables driving that system (state vector) by statistical optimization. When the observation vector is large, such as with satellite data, selecting a suitable dimension for the state vector is a challenge. A state vector that is too large cannot be effectively constrained by the observations, leading to smoothing error. However, reducing the dimension of the state vector leads to aggregation error as prior relationships between state vector elements are imposed rather than optimized. Here we present a method for quantifying aggregation and smoothing errors as a function of state vector dimension, so that a suitable dimension can be selected by minimizing the combined error. Reducing the state vector within the aggregation error constraints can have the added advantage of enabling analytical solution to the inverse problem with full error characterization. We compare three methods for reducing the dimension of the state vector from its native resolution: (1) merging adjacent elements (grid coarsening), (2) clustering with principal component analysis (PCA), and (3) applying a Gaussian mixture model (GMM) with Gaussian pdfs as state vector elements on which the native-resolution state vector elements are projected using radial basis functions (RBFs). The GMM method leads to somewhat lower aggregation error than the other methods, but more importantly it retains resolution of major local features in the state vector while smoothing weak and broad features.
Balancing aggregation and smoothing errors in inverse models
NASA Astrophysics Data System (ADS)
Turner, A. J.; Jacob, D. J.
2015-06-01
Inverse models use observations of a system (observation vector) to quantify the variables driving that system (state vector) by statistical optimization. When the observation vector is large, such as with satellite data, selecting a suitable dimension for the state vector is a challenge. A state vector that is too large cannot be effectively constrained by the observations, leading to smoothing error. However, reducing the dimension of the state vector leads to aggregation error as prior relationships between state vector elements are imposed rather than optimized. Here we present a method for quantifying aggregation and smoothing errors as a function of state vector dimension, so that a suitable dimension can be selected by minimizing the combined error. Reducing the state vector within the aggregation error constraints can have the added advantage of enabling analytical solution to the inverse problem with full error characterization. We compare three methods for reducing the dimension of the state vector from its native resolution: (1) merging adjacent elements (grid coarsening), (2) clustering with principal component analysis (PCA), and (3) applying a Gaussian mixture model (GMM) with Gaussian pdfs as state vector elements on which the native-resolution state vector elements are projected using radial basis functions (RBFs). The GMM method leads to somewhat lower aggregation error than the other methods, but more importantly it retains resolution of major local features in the state vector while smoothing weak and broad features.
Declining Prevalence of Disease Vectors Under Climate Change
NASA Astrophysics Data System (ADS)
Escobar, Luis E.; Romero-Alvarez, Daniel; Leon, Renato; Lepe-Lopez, Manuel A.; Craft, Meggan E.; Borbor-Cordova, Mercy J.; Svenning, Jens-Christian
2016-12-01
More than half of the world population is at risk of vector-borne diseases including dengue fever, chikungunya, zika, yellow fever, leishmaniasis, chagas disease, and malaria, with highest incidences in tropical regions. In Ecuador, vector-borne diseases are present from coastal and Amazonian regions to the Andes Mountains; however, a detailed characterization of the distribution of their vectors has never been carried out. We estimate the distribution of 14 vectors of the above vector-borne diseases under present-day and future climates. Our results consistently suggest that climate warming is likely threatening some vector species with extinction, locally or completely. These results suggest that climate change could reduce the burden of specific vector species. Other vector species are likely to shift and constrain their geographic range to the highlands in Ecuador potentially affecting novel areas and populations. These forecasts show the need for development of early prevention strategies for vector species currently absent in areas projected as suitable under future climate conditions. Informed interventions could reduce the risk of human exposure to vector species with distributional shifts, in response to current and future climate changes. Based on the mixed effects of future climate on human exposure to disease vectors, we argue that research on vector-borne diseases should be cross-scale and include climatic, demographic, and landscape factors, as well as forces facilitating disease transmission at fine scales.
Kaneko, Hidekazu; Tamura, Hiroshi; Tate, Shunta; Kawashima, Takahiro; Suzuki, Shinya S; Fujita, Ichiro
2010-08-01
In order for patients with disabilities to control assistive devices with their own neural activity, multineuronal spike trains must be efficiently decoded because only limited computational resources can be used to generate prosthetic control signals in portable real-time applications. In this study, we compare the abilities of two vectorizing procedures (multineuronal and time-segmental) to extract information from spike trains during the same total neuron-seconds. In the multineuronal vectorizing procedure, we defined a response vector whose components represented the spike counts of one to five neurons. In the time-segmental vectorizing procedure, a response vector consisted of components representing a neuron's spike counts for one to five time-segment(s) of a response period of 1 s. Spike trains were recorded from neurons in the inferior temporal cortex of monkeys presented with visual stimuli. We examined whether the amount of information of the visual stimuli carried by these neurons differed between the two vectorizing procedures. The amount of information calculated with the multineuronal vectorizing procedure, but not the time-segmental vectorizing procedure, significantly increased with the dimensions of the response vector. We conclude that the multineuronal vectorizing procedure is superior to the time-segmental vectorizing procedure in efficiently extracting information from neuronal signals. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Large Animal Models for Foamy Virus Vector Gene Therapy
Trobridge, Grant D.; Horn, Peter A.; Beard, Brian C.; Kiem, Hans-Peter
2012-01-01
Foamy virus (FV) vectors have shown great promise for hematopoietic stem cell (HSC) gene therapy. Their ability to efficiently deliver transgenes to multi-lineage long-term repopulating cells in large animal models suggests they will be effective for several human hematopoietic diseases. Here, we review FV vector studies in large animal models, including the use of FV vectors with the mutant O6-methylguanine-DNA methyltransferase, MGMTP140K to increase the number of genetically modified cells after transplantation. In these studies, FV vectors have mediated efficient gene transfer to polyclonal repopulating cells using short ex vivo transduction protocols designed to minimize the negative effects of ex vivo culture on stem cell engraftment. In this regard, FV vectors appear superior to gammaretroviral vectors, which require longer ex vivo culture to effect efficient transduction. FV vectors have also compared favorably with lentiviral vectors when directly compared in the dog model. FV vectors have corrected leukocyte adhesion deficiency and pyruvate kinase deficiency in the dog large animal model. FV vectors also appear safer than gammaretroviral vectors based on a reduced frequency of integrants near promoters and also near proto-oncogenes in canine repopulating cells. Together, these studies suggest that FV vectors should be highly effective for several human hematopoietic diseases, including those that will require relatively high percentages of gene-modified cells to achieve clinical benefit. PMID:23223198
Helminths as vectors of pathogens in vertebrate hosts: a theoretical approach.
Perkins, Sarah E; Fenton, Andy
2006-07-01
Pathogens frequently use vectors to facilitate transmission between hosts and, for vertebrate hosts, the vectors are typically ectoparasitic arthropods. However, other parasites that are intimately associated with their hosts may also be ideal candidate vectors; namely the parasitic helminths. Here, we present empirical evidence that helminth vectoring of pathogens occurs in a range of vertebrate systems by a variety of helminth taxa. Using a novel theoretical framework we explore the dynamics of helminth vectoring and determine which host-helminth-pathogen characteristics may favour the evolution of helminth vectoring. We use two theoretical models: the first is a population dynamic model amalgamated from standard macro- and microparasite models, which serves as a framework for investigation of within-host interactions between co-infecting pathogens and helminths. The second is an evolutionary model, which we use to predict the ecological conditions under which we would expect helminth vectoring to evolve. We show that, like arthropod vectors, helminth vectors increase pathogen fitness. However, unlike arthropod vectors, helminth vectoring increases the pathogenic impact on the host and may allow the evolution of high pathogen virulence. We show that concomitant infection of a host with a helminth and pathogen are not necessarily independent of one another, due to helminth vectoring of microparasites, with profound consequences for pathogen persistence and the impact of disease on the host population.
Multiple-mouse MRI with multiple arrays of receive coils.
Ramirez, Marc S; Esparza-Coss, Emilio; Bankson, James A
2010-03-01
Compared to traditional single-animal imaging methods, multiple-mouse MRI has been shown to dramatically improve imaging throughput and reduce the potentially prohibitive cost for instrument access. To date, up to a single radiofrequency coil has been dedicated to each animal being simultaneously scanned, thus limiting the sensitivity, flexibility, and ultimate throughput. The purpose of this study was to investigate the feasibility of multiple-mouse MRI with a phased-array coil dedicated to each animal. A dual-mouse imaging system, consisting of a pair of two-element phased-array coils, was developed and used to achieve acceleration factors greater than the number of animals scanned at once. By simultaneously scanning two mice with a retrospectively gated cardiac cine MRI sequence, a 3-fold acceleration was achieved with signal-to-noise ratio in the heart that is equivalent to that achieved with an unaccelerated scan using a commercial mouse birdcage coil. (c) 2010 Wiley-Liss, Inc.
Novel instrumentation for multifield time-lapse cinemicrography.
Kallman, R F; Blevins, N; Coyne, M A; Prionas, S D
1990-04-01
The most significant feature of the system that is described is its ability to image essentially simultaneously the growth of up to 99 single cells into macroscopic colonies, each in its own microscope field. Operationally, fields are first defined and programmed by a trained observer. All subsequent steps are automatic and under computer control. Salient features of the hardware are stepper motor-controlled movement of the stage and fine adjustment of an inverted microscope, a high-quality 16-mm cine camera with light meter and controls, and a miniature incubator in which cells may be grown under defined conditions directly on the microscope stage. This system, termed MUTLAS, necessitates reordering of the primary images by rephotographing them on fresh film. Software developed for the analysis of cell and colony growth requires frame-by-frame examination of the secondary film and the use of a mouse-driven cursor to trace microscopically visible (4X objective magnification) events.
Johannesen, Jes; Foissac, Xavier; Kehrli, Patrik; Maixner, Michael
2012-01-01
Dissemination of vector-transmitted pathogens depend on the survival and dispersal of the vector and the vector's ability to transmit the pathogen, while the host range of vector and pathogen determine the breath of transmission possibilities. In this study, we address how the interaction between dispersal and plant fidelities of a pathogen (stolbur phytoplasma tuf-a) and its vector (Hyalesthes obsoletus: Cixiidae) affect the emergence of the pathogen. Using genetic markers, we analysed the geographic origin and range expansion of both organisms in Western Europe and, specifically, whether the pathogen's dissemination in the northern range is caused by resident vectors widening their host-plant use from field bindweed to stinging nettle, and subsequent host specialisation. We found evidence for common origins of pathogen and vector south of the European Alps. Genetic patterns in vector populations show signals of secondary range expansion in Western Europe leading to dissemination of tuf-a pathogens, which might be newly acquired and of hybrid origin. Hence, the emergence of stolbur tuf-a in the northern range was explained by secondary immigration of vectors carrying stinging nettle-specialised tuf-a, not by widening the host-plant spectrum of resident vectors with pathogen transmission from field bindweed to stinging nettle nor by primary co-migration from the resident vector's historical area of origin. The introduction of tuf-a to stinging nettle in the northern range was therefore independent of vector's host-plant specialisation but the rapid pathogen dissemination depended on the vector's host shift, whereas the general dissemination elsewhere was linked to plant specialisation of the pathogen but not of the vector. PMID:23284774
Halbert, Christine L.; Allen, James M.; Miller, A. Dusty
2001-01-01
Although vectors derived from adeno-associated virus type 2 (AAV2) promote gene transfer and expression in many somatic tissues, studies with animal models and cultured cells show that the apical surface of airway epithelia is resistant to transduction by AAV2 vectors. Approaches to increase transduction rates include increasing the amount of vector and perturbing the integrity of the epithelia. In this study, we explored the use of vectors based on AAV6 to increase transduction rates in airways. AAV vectors were made using combinations of rep, cap, and packaged genomes from AAV2 or AAV6. The packaged genomes encoded human placental alkaline phosphatase and contained terminal repeat sequences from AAV2 or AAV6. We found that transduction efficiency was primarily dependent on the source of Cap protein, defined here as the vector pseudotype. The AAV6 and AAV2 pseudotype vectors exhibited different tropisms in tissue-cultured cells, and cell transduction by AAV6 vectors was not inhibited by heparin, nor did they compete for entry in a transduction assay, indicating that AAV6 and AAV2 capsid bind different receptors. In vivo analysis of vectors showed that AAV2 pseudotype vectors gave high transduction rates in alveolar cells but much lower rates in the airway epithelium. In contrast, the AAV6 pseudotype vectors exhibited much more efficient transduction of epithelial cells in large and small airways, showing up to 80% transduction in some airways. These results, combined with our previous results showing lower immunogenicity of AAV6 than of AAV2 vectors, indicate that AAV6 vectors may provide significant advantages over AAV2 for gene therapy of lung diseases like cystic fibrosis. PMID:11413329