Nicaise, C; Robert, C; Ancellin, J; Cazalaà, J B
1996-01-01
When plugging the O2, N2O and air hoses into the corresponding wall sockets, the air hose was wrongly inserted into the N2O wall outlet. This was made possible because of faulty retaining clasps of the male coupler of the air probe. French "fail-safe" connections consist of a two-clasp male coupler for air, three clasps for O2 and four clasps for N2O hoses. Additionally the clasps of the air probe are broader then those of the N2O probe. However, the latter difference was lost due to wear. The incident was recognized without delay as the N2O hose could not be inserted into the air outlet. However, it could have remained unnoticed had there been two N2O wall outlets and could have resulted in severe adverse effects.
Lightweight device to stimulate and monitor human vestibulo-ocular reflex
NASA Technical Reports Server (NTRS)
McStravick, M. Catherine (Inventor); Proctor, David R. (Inventor); Wood, Scott J. (Inventor)
1989-01-01
A helmet formed of a rigid shell is disclosed. The shell is lined with several air filled bladders to contact firmly the head of a user. The shell has a rigid chin bar supporting a bite bar connected fixedly to a mouthpiece bearing against the teeth and hard palate to firmly anchor the helmet without movement. The outer shell surface supports various air pumping bulbs and accelerometers. Separate left and right visor pivot on the side guided in a central tongue and groove track to move optical lens mounts into the user's field of vision. The chin bar is connected to the shell by a pair of releasable clasps. A safety lanyard connects to the clasps to quickly pull pins from the clasps to enable quick release in case of motion sickness.
Male-Male Clasping May Be Part of an Alternative Reproductive Tactic in Xenopus laevis
Rhodes, Heather J.; Stevenson, Rachel J.; Ego, Courtney L.
2014-01-01
Male Xenopus laevis frogs have been observed to clasp other males in a sustained, amplectant position, the purpose of which is unknown. We examined three possible hypotheses for this counter-intuitive behavior: 1) clasping males fail to discriminate the sex of the frogs they clasp; 2) male-male clasping is an aggressive or dominant behavior; or 3) that males clasp other males to gain proximity to breeding events and possibly engage in sperm competition. Our data, gathered through a series of behavioral experiments in the laboratory, refute the first two hypotheses. We found that males did not clasp indiscriminately, but showed a sex preference, with most males preferentially clasping a female, but a proportion preferentially clasping another male. Males that clasped another male when there was no female present were less likely to “win” reproductive access in a male-male-female triad, indicating that they did not establish dominance through clasping. However, those males did gain proximity to oviposition by continued male-male clasping in the presence of the female. Thus, our findings are consistent with, but cannot confirm, the third hypothesis of male-male clasping as an alternative reproductive tactic. PMID:24849114
Precision attachments for the partially dentate mouth
Preiskel, H W
1974-01-01
Some uses of precision attachments in restoring the partially dentate mouth are considered. These devices are indicated where neither the clasp-retained denture nor the fixed bridge is entirely suitable. ImagesFig. 2 PMID:4614689
CLASPs are required for proper microtubule localization of End-binding proteins
Grimaldi, Ashley D.; Maki, Takahisa; Fitton, Benjamin P.; Roth, Daniel; Yampolsky, Dmitry; Davidson, Michael W.; Svitkina, Tatyana; Straube, Anne; Hayashi, Ikuko; Kaverina, Irina
2014-01-01
Summary Microtubule (MT) plus-end tracking proteins (+TIPs) preferentially localize to MT plus-ends. End-binding proteins (EBs) are master regulators of the +TIP complex; however, it is unknown whether EBs are regulated by other +TIPs. Here, we show that Cytoplasmic linker associated proteins (CLASPs) modulate EB localization at MTs. In CLASP-depleted cells, EBs localized along the MT lattice in addition to plus-ends. The MT-binding region of CLASP was sufficient for restoring normal EB localization, while neither EB-CLASP interactions nor EB tail-binding proteins are involved. In vitro assays revealed that CLASP directly functions to remove EB from MTs. Importantly, this effect occurs specifically during MT polymerization, but not at pre-formed MTs. Increased GTP-tubulin content within MTs in CLASP-depleted cells suggests that CLASPs facilitate GTP-hydrolysis to reduce EB lattice binding. Together, these findings suggest that CLASPs influence the MT lattice itself to regulate EB and determine exclusive plus-end localization of EBs in cells. PMID:25117684
Finite element analysis on preferable I-bar clasp shape.
Sato, Y; Tsuga, K; Abe, Y; Asahara, S; Akagawa, Y
2001-05-01
An I-bar clasp is one of the most popular direct retainers for distal-extension removable partial dentures. However, no adequate information is available on preferable shape as determined by biomechanics. This study aimed (1) to investigate, by finite element analysis (FEA), the dimensions and stress of I-bar clasps having the same stiffness, and (2) to estimate a mechanically preferable clasp design. Three-dimensional FEA models of I-bar clasps were created with vertical and horizontal straight sections connected by a curved section characterized by six parameters: thickness of the clasp tip, width of the clasp tip, radius of the curvature, horizontal distance between the base and the vertical axis, vertical dimension between the tip and the horizontal axis, and taper (change of width per unit length along the axis). Stress was calculated with a concentrated load of 5 N applied 2 mm from the tip of the clasp in the buccal direction. A thinner and wider clasp having an taper of 0.020-0.023 and radius of curvature of 2.75-3.00 showed less stress. The results suggest that such a shape might be the preferable I-bar clasp shape as biomechanical viewpoint.
CLASP2: High-Precision Spectro-Polarimetery in Mg II h & k
NASA Technical Reports Server (NTRS)
Ishikawa, R.; McKenzie, D.; Trujillo Bueno, J.; Auchere, F.; Rachmeler, L.; Okamoto, T. J.; Kano, R.; Song, D.; Kubo, M.; Narukage, N.;
2017-01-01
The international team is promoting the CLASP2 (Chromospheric LAyer Spectro-Polarimeter 2) sounding rocket experiment, which is the re-flight of CLASP (2015). In this second flight, we will refit the existing CLASP instrument to measure all Stokes parameters in Mg II h k lines, and aim at inferring the magnetic field information in the upper chromosphere combining the Hanle and Zeeman effects. CLASP2 project was approved by NASA in December 2016, and is now scheduled to fly in 2019.
CLASP2 Links Reelin to the Cytoskeleton during Neocortical Development.
Dillon, Gregory M; Tyler, William A; Omuro, Kerilyn C; Kambouris, John; Tyminski, Camila; Henry, Shawna; Haydar, Tarik F; Beffert, Uwe; Ho, Angela
2017-03-22
The Reelin signaling pathway plays a crucial role in regulating neocortical development. However, little is known about how Reelin controls the cytoskeleton during neuronal migration. Here, we identify CLASP2 as a key cytoskeletal effector in the Reelin signaling pathway. We demonstrate that CLASP2 has distinct roles during neocortical development regulating neuron production and controlling neuron migration, polarity, and morphogenesis. We found downregulation of CLASP2 in migrating neurons leads to mislocalized cells in deeper cortical layers, abnormal positioning of the centrosome-Golgi complex, and aberrant length/orientation of the leading process. We discovered that Reelin regulates several phosphorylation sites within the positively charged serine/arginine-rich region that constitute consensus GSK3β phosphorylation motifs of CLASP2. Furthermore, phosphorylation of CLASP2 regulates its interaction with the Reelin adaptor Dab1 and this association is required for CLASP2 effects on neurite extension and motility. Together, our data reveal that CLASP2 is an essential Reelin effector orchestrating cytoskeleton dynamics during brain development. Copyright © 2017 Elsevier Inc. All rights reserved.
Basu, Sreya; Sladecek, Stefan; Pemble, Hayley; Wittmann, Torsten; Slotman, Johan A; van Cappellen, Wiggert; Brenner, Hans-Rudolf; Galjart, Niels
2014-10-31
The postsynaptic apparatus of the neuromuscular junction (NMJ) traps and anchors acetylcholine receptors (AChRs) at high density at the synapse. We have previously shown that microtubule (MT) capture by CLASP2, a MT plus-end-tracking protein (+TIP), increases the size and receptor density of AChR clusters at the NMJ through the delivery of AChRs and that this is regulated by a pathway involving neuronal agrin and several postsynaptic kinases, including GSK3. Phosphorylation by GSK3 has been shown to cause CLASP2 dissociation from MT ends, and nine potential phosphorylation sites for GSK3 have been mapped on CLASP2. How CLASP2 phosphorylation regulates MT capture at the NMJ and how this controls the size of AChR clusters are not yet understood. To examine this, we used myotubes cultured on agrin patches that induce AChR clustering in a two-dimensional manner. We show that expression of a CLASP2 mutant, in which the nine GSK3 target serines are mutated to alanine (CLASP2-9XS/9XA) and are resistant to GSK3β-dependent phosphorylation, promotes MT capture at clusters and increases AChR cluster size, compared with myotubes that express similar levels of wild type CLASP2 or that are noninfected. Conversely, myotubes expressing a phosphomimetic form of CLASP2 (CLASP2-8XS/D) show enrichment of immobile mutant CLASP2 in clusters, but MT capture and AChR cluster size are reduced. Taken together, our data suggest that both GSK3β-dependent phosphorylation and the level of CLASP2 play a role in the maintenance of AChR cluster size through the regulated capture and release of MT plus-ends. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.
NASA Technical Reports Server (NTRS)
Joiner, Reyann; Kobayashi, Ken; Winebarger, Amy; Champey, Patrick
2014-01-01
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding rocket instrument which is currently being developed by NASA's Marshall Space Flight Center (MSFC) and the National Astronomical Observatory of Japan (NAOJ). The goal of this instrument is to observe and detect the Hanle effect in the scattered Lyman-Alpha UV (121.6nm) light emitted by the Sun's Chromosphere to make measurements of the magnetic field in this region. In order to make accurate measurements of this effect, the performance characteristics of the three on-board charge-coupled devices (CCDs) must meet certain requirements. These characteristics include: quantum efficiency, gain, dark current, noise, and linearity. Each of these must meet predetermined requirements in order to achieve satisfactory performance for the mission. The cameras must be able to operate with a gain of no greater than 2 e(-)/DN, a noise level less than 25e(-), a dark current level which is less than 10e(-)/pixel/s, and a residual nonlinearity of less than 1%. Determining these characteristics involves performing a series of tests with each of the cameras in a high vacuum environment. Here we present the methods and results of each of these performance tests for the CLASP flight cameras.
Role of CLASP2 in microtubule stabilization and the regulation of persistent motility.
Drabek, Ksenija; van Ham, Marco; Stepanova, Tatiana; Draegestein, Katharina; van Horssen, Remco; Sayas, Carmen Laura; Akhmanova, Anna; Ten Hagen, Timo; Smits, Ron; Fodde, Riccardo; Grosveld, Frank; Galjart, Niels
2006-11-21
In motile fibroblasts, stable microtubules (MTs) are oriented toward the leading edge of cells. How these polarized MT arrays are established and maintained, and the cellular processes they control, have been the subject of many investigations. Several MT "plus-end-tracking proteins," or +TIPs, have been proposed to regulate selective MT stabilization, including the CLASPs, a complex of CLIP-170, IQGAP1, activated Cdc42 or Rac1, a complex of APC, EB1, and mDia1, and the actin-MT crosslinking factor ACF7. By using mouse embryonic fibroblasts (MEFs) in a wound-healing assay, we show here that CLASP2 is required for the formation of a stable, polarized MT array but that CLIP-170 and an APC-EB1 interaction are not essential. Persistent motility is also hampered in CLASP2-deficient MEFs. We find that ACF7 regulates cortical CLASP localization in HeLa cells, indicating it acts upstream of CLASP2. Fluorescence-based approaches show that GFP-CLASP2 is immobilized in a bimodal manner in regions near cell edges. Our results suggest that the regional immobilization of CLASP2 allows MT stabilization and promotes directionally persistent motility in fibroblasts.
Analysis of stiffness and stress in I-bar clasps.
Sato, Y; Tsuga, K; Abe, Y; Asahara, S; Akagawa, Y
2001-06-01
An I-bar clasp is one of the most popular direct retainers for distal-extension removable partial dentures. However, no adequate information is available on the shape associated with biomechanics. This study aimed (1) to establish a three-dimensional (3D) finite-element modelling method of I-bar clasps, and (2) to clarify the effect of the shape on the stress and stiffness of I-bar clasps. 3D computer models of I-bar clasps were created with vertical and horizontal straight sections connected with a curved section with six parameters: thickness of the clasp tip (T), width of the clasp tip (W), radius of the curvature (R), horizontal distance between the base and the vertical axis (H), vertical dimension between the tip and the horizontal axis (V), taper (change of width per unit length along the axis)(Tp). Stress decreased as T, W, R and Tp increased, and as V decreased. Stiffness (which is proportional to retention) increased as T, W, R and Tp increased, and as H and V decreased. In both stress and stiffness, the effects of T and Tp were especially large. From the results, a systematic formula between the clasp shape and the stiffness was derived.
An analytical model to design circumferential clasps for laser-sintered removable partial dentures.
Alsheghri, Ammar A; Alageel, Omar; Caron, Eric; Ciobanu, Ovidiu; Tamimi, Faleh; Song, Jun
2018-06-21
Clasps of removable partial dentures (RPDs) often suffer from plastic deformation and failure by fatigue; a common complication of RPDs. A new technology for processing metal frameworks for dental prostheses based on laser-sintering, which allows for precise fabrication of clasp geometry, has been recently developed. This study sought to propose a novel method for designing circumferential clasps for laser-sintered RPDs to avoid plastic deformation or fatigue failure. An analytical model for designing clasps with semicircular cross-sections was derived based on mechanics. The Euler-Bernoulli elastic curved beam theory and Castigliano's energy method were used to relate the stress and undercut with the clasp length, cross-sectional radius, alloy properties, tooth type, and retention force. Finite element analysis (FEA) was conducted on a case study and the resultant tensile stress and undercut were compared with the analytical model predictions. Pull-out experiments were conducted on laser-sintered cobalt-chromium (Co-Cr) dental prostheses to validate the analytical model results. The proposed circumferential clasp design model yields results in good agreement with FEA and experiments. The results indicate that Co-Cr circumferential clasps in molars that are 13mm long engaging undercuts of 0.25mm should have a cross-section radius of 1.2mm to provide a retention of 10N and to avoid plastic deformation or fatigue failure. However, shorter circumferential clasps such as those in premolars present high stresses and cannot avoid plastic deformation or fatigue failure. Laser-sintered Co-Cr circumferential clasps in molars are safe, whereas they are susceptible to failure in premolars. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Joiner, R. K.; Kobayashi, K.; Winebarger, A. R.; Champey, P. R.
2014-12-01
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding rocket instrument which is currently being developed by NASA's Marshall Space Flight Center (MSFC) and the National Astronomical Observatory of Japan (NAOJ). The goal of this instrument is to observe and detect the Hanle effect in the scattered Lyman-Alpha UV (121.6nm) light emitted by the Sun's Chromosphere to make measurements of the magnetic field in this region. In order to make accurate measurements of this effect, the performance characteristics of the three on-board charge-coupled devices (CCDs) must meet certain requirements. These characteristics include: quantum efficiency, gain, dark current, noise, and linearity. Each of these must meet predetermined requirements in order to achieve satisfactory performance for the mission. The cameras must be able to operate with a gain of no greater than 2 e-/DN, a noise level less than 25e-, a dark current level which is less than 10e-/pixel/s, and a residual non-linearity of less than 1%. Determining these characteristics involves performing a series of tests with each of the cameras in a high vacuum environment. Here we present the methods and results of each of these performance tests for the CLASP flight cameras.
Ozawa, Daisuke; Suzuki, Yasunori; Kawamura, Noboru; Ohkubo, Chikahiro
2015-04-01
A crown restoration engaged by a clasp as an abutment tooth for a removable partial denture (RPD) occasionally might be removed and eliminated due to secondary caries or apical lesions. However, if the RPD is clinically acceptable without any problems and refabricating the RPD is not recommended, the new crown must be made to retrofit to the existing clasp of the RPD. This in vitro study evaluated the conventional and CAD/CAM procedures for retrofitting crown restorations to the existing clasps by measuring the fitness accuracy and the retentive forces. The crown restoration on #44 was fabricated with CP titanium and zirconium on the plaster model with #45 and #46 teeth missing to retrofit to the existing clasp using conventional thin coping and CAD/CAM procedures. The gap distance between the clasp (tip, shoulder, and rest regions) and the fabricated crown was measured using silicone impression material. The retentive force of the clasp was also measured, using an autograph at a crosshead speed of 50mm/min. The obtained data were analyzed by one-way ANOVA/Tukey's multiple comparison test (α=0.05). The CAD/CAM procedure caused significantly smaller gap distances in all of the clasp regions, as compared to the conventional procedure (p<0.05). The retentive force of the CAD/CAM crown was significantly higher than for the conventional one (p<0.05). When a crown restoration must be remade to retrofit an existing clasp, CAD/CAM fabrication can be recommended so that both appropriate fitness and retentive force are obtained. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Yan, Hai-xin; Zhao, Yan-bo; Qin, Li-mei; Zhu, Hai-ting; Wu, Lin
2015-12-01
To investigate the changes of retentive force of cobalt-chromium alloy, pure titanium and vitallium cast clasps in the simulated 3-year clinical use. Fifteen metal abutment crowns made of No.QT800-2 nodular cast iron were used in the test. Five clasps from each of the following alloys: cobalt-chromium alloy, pure titanium and vitallium were fabricated. The undercut depth was 0.25 mm. A masticatory simulator was used to cycle the clasp on and off the metal abutment crown 5000 times, simulating 3-year clinical use. Retentive force was measured 11 times during this process. SPSS13.0 software package was used to analyze the results. Casting defects were observed using X-ray non destructive testing (X-ray NDT) before cyclic test. Surface characteristics were qualitatively evaluated using scanning electron microscope (SEM) before and after cyclic test. The results indicated that there were significant differences (P=0.000) in the retentive force of the 3 groups before and after the cyclic test. The highest retentive force was recorded in the vitallium clasps, and the lowest retentive force was measured in the pure titanium clasps. The results of X-ray NDT depicted the typical casting defect seen at the end of the connector. SEM examination revealed that no evidence of pores and cracks in the inner surfaces of the 3 groups was found before cyclic test. Wear was evident in the inner surfaces of the 3 groups but none of the clasps exhibited any evidence of cracks after cyclic test through SEM examination. In this in vitro test, vitallium clasps show the best retentive force in the 3 groups before and after 5000 cycles at 0.25 mm undercut depth. Cobalt-chromium alloy and vitallium clasps can maintain ideal retentive force at 0.25mm undercut depth in the long-term use. Wear may be one of the reasons for the loss of retentive force of clasps in the cyclic test.
NASA Technical Reports Server (NTRS)
Joiner, Reyann; Kobayashi, Ken; Winebarger, Amy; Champey, Patrick
2014-01-01
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding rocket instrument currently being developed by NASA's Marshall Space Flight Center (MSFC), the National Astronomical Observatory of Japan (NAOJ), and other partners. The goal of this instrument is to observe and detect the Hanle effect in the scattered Lyman-Alpha UV (121.6nm) light emitted by the Sun's chromosphere. The polarized spectrum imaged by the CCD cameras will capture information about the local magnetic field, allowing for measurements of magnetic strength and structure. In order to make accurate measurements of this effect, the performance characteristics of the three on- board charge-coupled devices (CCDs) must meet certain requirements. These characteristics include: quantum efficiency, gain, dark current, read noise, and linearity. Each of these must meet predetermined requirements in order to achieve satisfactory performance for the mission. The cameras must be able to operate with a gain of 2.0+/- 0.5 e--/DN, a read noise level less than 25e-, a dark current level which is less than 10e-/pixel/s, and a residual non- linearity of less than 1%. Determining these characteristics involves performing a series of tests with each of the cameras in a high vacuum environment. Here we present the methods and results of each of these performance tests for the CLASP flight cameras.
NASA Technical Reports Server (NTRS)
1994-01-01
The Data Egg, a prototype chord key-based data entry device, can be used autonomously or as an auxiliary keyboard with a personal computer. Data is entered by pressing combinations of seven buttons positioned where the fingers naturally fall when clasping the device. An experienced user can enter text at 30 to 35 words per minute. No transcription is required. The input is downloaded into a computer and printed. The Data Egg can be used by an astronaut in space, a journalist, a bedridden person, etc. It was developed by a Jet Propulsion Laboratory engineer. Product is not currently manufactured.
High-Reflectivity Multi-Layer Coatings for the CLASP Sounding Rocket Project
NASA Technical Reports Server (NTRS)
Narukage, Noriyuki; Kano, Ryohei; Bando, Takamasa; Ishikawa, Ryoko; Kubo, Masahito; Katsukawa, Yukio; Ishikawa, Shin-nosuke; Kobiki, Toshihiko; Giono, Gabriel; Auchere, Frederic;
2015-01-01
We are planning an international rocket experiment Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is (2015 planned) that Lyman alpha line (Ly alpha line) polarization spectroscopic observations from the sun. The purpose of this experiment, detected with high accuracy of the linear polarization of the Ly alpha lines to 0.1% by using a Hanle effect is to measure the magnetic field of the chromosphere-transition layer directly. For polarization photometric accuracy achieved that approximately 0.1% required for CLASP, it is necessary to realize the monitoring device with a high throughput. On the other hand, Ly alpha line (vacuum ultraviolet rays) have a sensitive characteristics that is absorbed by the material. We therefore set the optical system of the reflection system (transmission only the wavelength plate), each of the mirrors, subjected to high efficiency of the multilayer coating in accordance with the role. Primary mirror diameter of CLASP is about 30 cm, the amount of heat about 30,000 J is about 5 minutes of observation time is coming mainly in the visible light to the telescope. In addition, total flux of the sun visible light overwhelmingly large and about 200 000 times the Ly alpha line wavelength region. Therefore, in terms of thermal management and 0.1% of the photometric measurement accuracy achieved telescope, elimination of the visible light is essential. We therefore, has a high reflectivity (greater than 50%) in Ly alpha line, visible light is a multilayer coating be kept to a low reflectance (less than 5%) (cold mirror coating) was applied to the primary mirror. On the other hand, the efficiency of the polarization analyzer required chromospheric magnetic field measurement (the amount of light) Conventional (magnesium fluoride has long been known as a material for vacuum ultraviolet (MgF2) manufactured ellipsometer; Rs = 22%) about increased to 2.5 times were high efficiency reflective polarizing element analysis. This device, Bridou et al. (2011) is proposed "that is coated with a thin film of the substrate MgF2 and SiO2 fused silica." As a result of the measurement, Rs = 54.5%, to achieve a Rp = 0.3%, high efficiency, of course, capable of taking out only about spolarized light. Other reflective optical elements (the secondary mirror, the diffraction grating-collector mirror), subjected to high-reflection coating of Al + MgF2 (reflectance of about 80%), less than 5% in the entire optical system by these (CCD Science was achieved a high throughput as a device for a vacuum ultraviolet ray of the entire system less than 5% (CCD of QE is not included).
NASA Technical Reports Server (NTRS)
Narukage, Noriyuki; Kano, Ryohei; Bando, Takamasa; Ishikawa, Ryoko; Kubo, Masahito; Katsukawa, Yukio; Ishikawa, Shinnosuke; Hara, Hiroshi; Suematsu, Yoshinori; Giono, Gabriel;
2015-01-01
We are planning an international rocket experiment Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is (2015 planned) that Lyman a line (Ly(alpha) line) polarization spectroscopic observations from the sun. The purpose of this experiment, detected with high accuracy of the linear polarization of the Ly(alpha) lines to 0.1% by using a Hanle effect is to measure the magnetic field of the chromosphere-transition layer directly. For polarization photometric accuracy achieved that approx. 0.1% required for CLASP, it is necessary to realize the monitoring device with a high throughput. On the other hand, Ly(alpha) line (vacuum ultraviolet rays) have a sensitive characteristics that is absorbed by the material. We therefore set the optical system of the reflection system (transmission only the wavelength plate), each of the mirrors, subjected to high efficiency of the multilayer coating in accordance with the role. Primary mirror diameter of CLASP is about 30 cm, the amount of heat about 30,000 J is about 5 minutes of observation time is coming mainly in the visible light to the telescope. In addition, total flux of the sun visible light overwhelmingly large and about 200 000 times the Ly(alpha) line wavelength region. Therefore, in terms of thermal management and 0.1% of the photometric measurement accuracy achieved telescope, elimination of the visible light is essential. We therefore, has a high reflectivity (> 50%) in Lya line, visible light is a multilayer coating be kept to a low reflectance (<5%) (cold mirror coating) was applied to the primary mirror. On the other hand, the efficiency of the polarization analyzer required chromospheric magnetic field measurement (the amount of light) Conventional (magnesium fluoride has long been known as a material for vacuum ultraviolet (MgF2) manufactured ellipsometer; Rs = 22%) about increased to 2.5 times were high efficiency reflective polarizing element analysis. This device, Bridou et al. (2011) is proposed "that is coated with a thin film of the substrate MgF2 and SiO2 fused silica." As a result of the measurement, Rs = 54.5%, to achieve a Rp = 0.3%, high efficiency, of course, capable of taking out only about s-polarized light. Other reflective optical elements (the secondary mirror, the diffraction gratingcollector mirror), subjected to high-reflection coating of Al + MgF2 (reflectance of about 80%), less than 5% in the entire optical system by these (CCD Science was achieved a high throughput as a device for a vacuum ultraviolet ray of the entire system less than 5% (CCD of QE is not included).
Arimori, Takao; Kitago, Yu; Umitsu, Masataka; Fujii, Yuki; Asaki, Ryoko; Tamura-Kawakami, Keiko; Takagi, Junichi
2017-10-03
Antibody fragments are frequently used as a "crystallization chaperone" to aid structural analysis of complex macromolecules that are otherwise crystallization resistant, but conventional fragment formats have not been designed for this particular application. By fusing an anti-parallel coiled-coil structure derived from the SARAH domain of human Mst1 kinase to the variable region of an antibody, we succeeded in creating a novel chimeric antibody fragment of ∼37 kDa, termed "Fv-clasp," which exhibits excellent crystallization compatibility while maintaining the binding ability of the original IgG molecule. The "clasp" and the engineered disulfide bond at the bottom of the Fv suppressed the internal mobility of the fragment and shielded hydrophobic residues, likely contributing to the high heat stability and the crystallizability of the Fv-clasp. Finally, Fv-clasp antibodies showed superior "chaperoning" activity over conventional Fab fragments, and facilitated the structure determination of an ectodomain fragment of integrin α6β1. Copyright © 2017 Elsevier Ltd. All rights reserved.
In-Flight Performance of the Polarization Modulator in the CLASP Rocket Experiment
NASA Technical Reports Server (NTRS)
Ishikawa, Shin-nosuke; Shimizu, Toshifumi; Kano, Ryohei; Bando, Takamasa; Ishikawa, Ryoko; Giono, Gabriel; Beabout, Dyana L.; Beabout, Brent L.; Nakayama, Satoshi; Tajima, Takao
2016-01-01
We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman-alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman-alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non-uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.
NASA Astrophysics Data System (ADS)
Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, D.; Beabout, B.; Stewart, M.
2014-07-01
The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-α and to detect the Hanle effect in the line core. Due to the nature of Lyman-α polarizationin the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1% in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1% polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. The CLASP cameras were designed to operate with ≤ 10 e-/pixel/second dark current, ≤ 25 e- read noise, a gain of 2.0 +- 0.5 and ≤ 1.0% residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.
Baltag, Ioana; Watanabe, Kouichi; Miyakawa, Osamu
2005-06-01
The behavior of molten titanium in molds of complicated shape is still insufficiently understood; consequently, definite spruing criteria are not yet available for titanium RPD frameworks. This study investigated the influence of sprue design on porosity in pressure-cast titanium circumferential clasps. The patterns of 90 circumferential clasps were sprued with three directions (0, 30 and 60 degrees , as measured between the sprue and the symmetry plane of the clasp assembly) and three sprue diameters (1.5, 2.0 and 2.5mm). CPTi was cast in a one-chamber pressure casting machine. Pore number and size were assessed on radiographs of the castings. Statistical analysis was done by two-way analysis of variance (ANOVA), followed by Fisher's PLSD post hoc test. The porosity in lingual arms increased significantly with increase of sprue diameter and sprue angle, while the porosity in minor connectors had an inversely proportional distribution. Very low porosity, uninfluenced by sprue design, was found in buccal arms. In conclusion, internal porosity in titanium circumferential clasp arms can be minimized through sprue design: the 0 degrees sprue direction produced the least porosity, while for the 30 and 60 degrees directions, 1.5mm diameter sprues produced lower porosity than 2.0 and 2.5mm diameter sprues. In this study, the lowest porosity in titanium circumferential clasp arms was obtained with sprues attached perpendicularly to the minor connectors, regardless of sprue diameter. Conventional sprue directions produced significantly higher porosity in clasp lingual arms, the amount of porosity increasing with sprue diameter.
In-flight performance of the polarization modulator in the CLASP rocket experiment
NASA Astrophysics Data System (ADS)
Ishikawa, Shin-nosuke; Shimizu, Toshifumi; Kano, Ryohei; Bando, Takamasa; Ishikawa, Ryoko; Giono, Gabriel; Beabout, Dyana L.; Beabout, Brent L.; Nakayama, Satoshi; Tajima, Takao
2016-07-01
We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman-alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman-alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non- uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.
CLASP2: The Chromospheric LAyer Spectro-Polarimeter
NASA Astrophysics Data System (ADS)
Rachmeler, Laurel; E McKenzie, David; Ishikawa, Ryohko; Trujillo Bueno, Javier; Auchère, Frédéric; Kobayashi, Ken; Winebarger, Amy; Bethge, Christian; Kano, Ryouhei; Kubo, Masahito; Song, Donguk; Narukage, Noriyuki; Ishikawa, Shin-nosuke; De Pontieu, Bart; Carlsson, Mats; Yoshida, Masaki; Belluzzi, Luca; Stepan, Jiri; del Pino Alemná, Tanausú; Ballester, Ernest Alsina; Asensio Ramos, Andres
2017-08-01
We present the instrument, science case, and timeline of the CLASP2 sounding rocket mission. The successful CLASP (Chromospheric Lyman-Alpha Spectro-Polarimeter) sounding rocket flight in 2015 resulted in the first-ever linear polarization measurements of solar hydrogen Lyman-alpha line, which is sensitive to the Hanle effect and can be used to constrain the magnetic field and geometric complexity of the upper chromosphere. Ly-alpha is one of several upper chromospheric lines that contain magnetic information. In the spring of 2019, we will re-fly the modified CLASP telescope to measure the full Stokes profile of Mg II h & k near 280 nm. This set of lines is sensitive to the upper chromospheric magnetic field via both the Hanle and the Zeeman effects.
NASA Technical Reports Server (NTRS)
Champey, Patrick; Kobayashi, Ken; Winebarger, Amy; Cirtin, Jonathan; Hyde, David; Robertson, Bryan; Beabout, Brent; Beabout, Dyana; Stewart, Mike
2014-01-01
The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1% in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1% polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30%) quantum efficiency at the Lyman-$\\alpha$ line. The CLASP cameras were designed to operate with =10 e- /pixel/second dark current, = 25 e- read noise, a gain of 2.0 and =0.1% residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.
A Sounding Rocket Experiment for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)
NASA Technical Reports Server (NTRS)
Kubo, M.; Kano, R.; Kobayashi, K.; Ishikawa, R.; Bando, T.; Narukage, N.; Katsukawa, Y.; Ishikawa, S.; Suematsu, Y.; Hara, H.;
2014-01-01
A sounding-rocket experiment called the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is presently under development to measure the linear polarization profiles caused by scattering processes and the Hanle effect in the hydrogen Lyman-alpha line (121.567nm). Accurate measurements of the linear polarization signals caused by scattering processes and the Hanle effect are essential to explore the strength and structures of weak magnetic fields. The primary target of future solar telescopes is to measure the weak magnetic field in outer solar atmospheres (from the chromosphere to the corona through the transition region). The hydrogen Lyman-alpha-line is one of the best lines for the diagnostics of magnetic fields in the outer solar atmospheres. CLASP is to be launched in 2015, and will provide, for the first time, the observations required for magnetic field measurements in the upper chromosphere and transition region. CLASP is designed to have a polarimetric sensitivity of 0.1% and a spectral resolution of 0.01nm for the Lyman-alpha line. CLASP will measure two orthogonal polarizations simultaneously for about 5-minute flight. Now the integration of flight mirrors and structures is in progress. In addition to our strategy to realize such a high-precision spectro-polarimetry in the UV, we will present a progress report on our pre-launch evaluation of optical and polarimetric performances of CLASP.
34. Detail of neck and shoulder connection showing toga clasp ...
34. Detail of neck and shoulder connection showing toga clasp and shoulder lights that improved nighttime illumination of head. May 1984. - Statue of Liberty, Liberty Island, Manhattan, New York County, NY
Huber, Sandra; Theiler, Romina; de Quervain, Daniel; Wiens, Olga; Karangenc, Tulin; Heussler, Volker; Dobbelaere, Dirk
2017-01-01
ABSTRACT Theileria is an apicomplexan parasite whose presence within the cytoplasm of a leukocyte induces cellular transformation and causes uncontrolled proliferation and clonal expansion of the infected cell. The intracellular schizont utilizes the host cell’s own mitotic machinery to ensure its distribution to both daughter cells by associating closely with microtubules (MTs) and incorporating itself within the central spindle. We show that CLASP1, an MT-stabilizing protein that plays important roles in regulating kinetochore-MT attachment and central spindle positioning, is sequestered at the Theileria annulata schizont surface. We used live-cell imaging and immunofluorescence in combination with MT depolymerization assays to demonstrate that CLASP1 binds to the schizont surface in an MT-independent manner throughout the cell cycle and that the recruitment of the related CLASP2 protein to the schizont is MT dependent. By transfecting Theileria-infected cells with a panel of truncation mutants, we found that the kinetochore-binding domain of CLASP1 is necessary and sufficient for parasite localization, revealing that CLASP1 interaction with the parasite occurs independently of EB1. We overexpressed the MT-binding domain of CLASP1 in parasitized cells. This exhibited a dominant negative effect on host MT stability and led to altered parasite size and morphology, emphasizing the importance of proper MT dynamics for Theileria partitioning during host cell division. Using coimmunoprecipitation, we demonstrate that CLASP1 interacts, directly or indirectly, with the schizont membrane protein p104, and we describe for the first time TA03615, a Theileria protein which localizes to the parasite surface, where it has the potential to participate in parasite-host interactions. IMPORTANCE T. annulata, the only eukaryote known to be capable of transforming another eukaryote, is a widespread parasite of veterinary importance that puts 250 million cattle at risk worldwide and limits livestock development for some of the poorest people in the world. Crucial to the pathology of Theileria is its ability to interact with host microtubules and the mitotic spindle of the infected cell. This study builds on our previous work in investigating the host and parasite molecules involved in mediating this interaction. Because it is not possible to genetically manipulate Theileria schizonts, identifying protein interaction partners is critical to understanding the function of parasite proteins. By identifying two Theileria surface proteins that are involved in the interaction between CLASP1 and the parasite, we provide important insights into the molecular basis of Theileria persistence within a dividing cell. PMID:28861517
In-Flight Performance of the Polarization Modulator in the CLASP Rocket Experiment
NASA Technical Reports Server (NTRS)
Ishikawa, S.; Shimizu, T.; Kano, R.; Bando, T.; Ishikawa, R.; Giono, G.; Beabout, D.; Beabout, B.; Nakayama, S.; Tajima, T.
2016-01-01
We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. We applied this PMU for the Chromospheric Lyman-alpha SpectroPolarimeter (CLASP), a sounding rocket experiment to observe the linear polarization of the Lyman-alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1% for the first time and investigate the vector magnetic field. Rotation non-uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. In the ground tests, we confirmed that PMU has superior rotation uniformity. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity during the flight and the high precision polarization measurement of CLASP was successfully achieved.
Chromospheric LAyer SpectroPolarimeter (CLASP2)
NASA Technical Reports Server (NTRS)
Narukage, Noriyuki; Cirtain, Jonathan W.; Ishikawa, Ryoko; Trujillo-Bueno, Javier; De Pontieu, Bart; Kubo, Masahito; Ishikawa, Shinnosuke; Kano, Ryohei; Suematsu, Yoshinori; Yoshida, Masaki;
2016-01-01
The sounding rocket Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) was launched on September 3rd, 2015, and successfully detected (with a polarization accuracy of 0.1 %) the linear polarization signals (Stokes Q and U) that scattering processes were predicted to produce in the hydrogen Lyman-alpha line (Ly; 121.567 nm). Via the Hanle effect, this unique data set may provide novel information about the magnetic structure and energetics in the upper solar chromosphere. The CLASP instrument was safely recovered without any damage and we have recently proposed to dedicate its second ight to observe the four Stokes profiles in the spectral region of the Mg II h and k lines around 280 nm; in these lines the polarization signals result from scattering processes and the Hanle and Zeeman effects. Here we describe the modifications needed to develop this new instrument called the "Chromospheric LAyer SpectroPolarimeter" (CLASP2).
Pietra, Stefano; Gustavsson, Anna; Kiefer, Christian; Kalmbach, Lothar; Hörstedt, Per; Ikeda, Yoshihisa; Stepanova, Anna N; Alonso, Jose M; Grebe, Markus
2013-01-01
The orientation of cell division and the coordination of cell polarity within the plane of the tissue layer (planar polarity) contribute to shape diverse multicellular organisms. The root of Arabidopsis thaliana displays regularly oriented cell divisions, cell elongation and planar polarity providing a plant model system to study these processes. Here we report that the SABRE protein, which shares similarity with proteins of unknown function throughout eukaryotes, has important roles in orienting cell division and planar polarity. SABRE localizes at the plasma membrane, endomembranes, mitotic spindle and cell plate. SABRE stabilizes the orientation of CLASP-labelled preprophase band microtubules predicting the cell division plane, and of cortical microtubules driving cell elongation. During planar polarity establishment, sabre is epistatic to clasp at directing polar membrane domains of Rho-of-plant GTPases. Our findings mechanistically link SABRE to CLASP-dependent microtubule organization, shedding new light on the function of SABRE-related proteins in eukaryotes.
A Sounding Rocket Experiment for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)
NASA Astrophysics Data System (ADS)
Kubo, M.; Kano, R.; Kobayashi, K.; Bando, T.; Narukage, N.; Ishikawa, R.; Tsuneta, S.; Katsukawa, Y.; Ishikawa, S.; Suematsu, Y.; Hara, H.; Shimizu, T.; Sakao, T.; Ichimoto, K.; Goto, M.; Holloway, T.; Winebarger, A.; Cirtain, J.; De Pontieu, B.; Casini, R.; Auchère, F.; Trujillo Bueno, J.; Manso Sainz, R.; Belluzzi, L.; Asensio Ramos, A.; Štěpán, J.; Carlsson, M.
2014-10-01
A sounding-rocket experiment called the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is presently under development to measure the linear polarization profiles in the hydrogen Lyman-alpha (Lyα) line at 121.567 nm. CLASP is a vacuum-UV (VUV) spectropolarimeter to aim for first detection of the linear polarizations caused by scattering processes and the Hanle effect in the Lyα line with high accuracy (0.1%). This is a fist step for exploration of magnetic fields in the upper chromosphere and transition region of the Sun. Accurate measurements of the linear polarization signals caused by scattering processes and the Hanle effect in strong UV lines like Lyα are essential to explore with future solar telescopes the strength and structures of the magnetic field in the upper chromosphere and transition region of the Sun. The CLASP proposal has been accepted by NASA in 2012, and the flight is planned in 2015.
Simulation and Measurement of Stray Light in the CLASP
NASA Technical Reports Server (NTRS)
Narukage, Noriyuki; Kano, Ryohei; Bando, Takamasa; Ishikawa, Ryoko; Kubo, Masahito; Tsuzuki, Toshihiro; Katsukawa, Yukio; Ishikawa, Shin-nosuke; Giono, Gabriel; Suematsu, Yoshinori;
2015-01-01
We are planning an international rocket experiment Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is (2015 planned) that Lyman Alpha line polarization spectroscopic observations from the sun. The purpose of this experiment, detected with high accuracy of the linear polarization of the Ly?? lines to 0.1% by using a Hanle effect is to measure the magnetic field of the chromosphere-transition layer directly. For total flux of the sun visible light overwhelmingly larger and about 200 000 times the Ly?? line wavelength region, also hinder to 0.1% of the polarization photometric accuracy achieved in the stray light of slight visible light. Therefore we were first carried out using the illumination design analysis software called stray light simulation CLASP Light Tools. Feature of this simulation, using optical design file (ZEMAX format) and structural design file (STEP format), to reproduce realistic CLASP as possible to calculate machine is that it was stray study. And, at the stage in the actual equipment that made the provisional set of CLASP, actually put sunlight into CLASP using coelostat of National Astronomical Observatory of Japan, was subjected to measurement of stray light (San test). Pattern was not observed in the simulation is observed in the stray light measurement results need arise that measures. However, thanks to the stray light measurement and simulation was performed by adding, it was found this pattern is due to the diffracted light at the slit. Currently, the simulation results is where you have taken steps to reference. In this presentation, we report the stray light simulation and stray light measurement results that we have implemented
Sotiriou, Michael; Zissis, Alcibiades
2014-01-01
Objective The aim of this survey was to record removable partial denture (RPD) retentive elements and abutment teeth in partially edentulous patients, identified in commercial laboratories in Athens, Greece. Material and Methods 628 master casts with the corresponding cast metal frameworks used in the construction of RPDs were evaluated. Casts were photographed to identify the number and position of existing teeth, the partial edentulism class and the retentive elements. Prevalence tables and the x2 test were used for the statistical analysis of the collected data (α=.05). Results There were 276 maxillary (43.9%) and 352 (56.1%) mandibular casts. Maxillary edentulism entailed almost a total absence of right third molars in 96.7% and left third molars 96.0% of casts, with lower rates for the first and second molars. Edentulism in the posterior mandible presented a similar pattern. The most profound findings concerning retentive elements were: 91.9% of the retainers used were clasps and the remaining 8.1% were attachments. Of the clasps used, 48.9% were of the Roach Τ type, a finding more common in Kennedy Class I as compared to other Kennedy Classes (p<0.01). The circumferential clasps accounted for 19.3% of the total clasps used, and it was less frequently presented (8.8%) in Kennedy I Classes (p<0.01). Conclusions Roach clasps were used in the majority of cases whereas RPI clasps and attachments were rarely used. PMID:27688367
NASA Technical Reports Server (NTRS)
Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, D.; Beabout, B.; Stewart, M.
2014-01-01
The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with 10 e-/pixel/second dark current, 25 e- read noise, a gain of 2.0 +/- 0.5 and 1.0 percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.
CLASP2 interacts with p120-catenin and governs microtubule dynamics at adherens junctions
Shahbazi, Marta N.; Megias, Diego; Epifano, Carolina; Akhmanova, Anna; Gundersen, Gregg G.; Fuchs, Elaine
2013-01-01
Classical cadherins and their connections with microtubules (MTs) are emerging as important determinants of cell adhesion. However, the functional relevance of such interactions and the molecular players that contribute to tissue architecture are still emerging. In this paper, we report that the MT plus end–binding protein CLASP2 localizes to adherens junctions (AJs) via direct interaction with p120-catenin (p120) in primary basal mouse keratinocytes. Reductions in the levels of p120 or CLASP2 decreased the localization of the other protein to cell–cell contacts and altered AJ dynamics and stability. These features were accompanied by decreased MT density and altered MT dynamics at intercellular junction sites. Interestingly, CLASP2 was enriched at the cortex of basal progenitor keratinocytes, in close localization to p120. Our findings suggest the existence of a new mechanism of MT targeting to AJs with potential functional implications in the maintenance of proper cell–cell adhesion in epidermal stem cells. PMID:24368809
NASA Technical Reports Server (NTRS)
Stepan, J.; Trujillo Bueno, J.; Gunar, S.; del Pino Aleman, T.; Heinzel, P.; Kano, R.; Ishikawa, R.; Narukage, M.; Bando, T.; Winebarger, Amy;
2016-01-01
The 400 arcsec spectrograph slit of CLASP crossed predominantly quiet regions of the solar chromosphere, from the limb towards the solar disk center. Interestingly, in the CLASP slit-jaw images and in the SDO images of the He I line at 304 A, we can identify a filament channel (FC) extending over more than 60 arcsec crossing the spectrograph slit. In order to interpret the peculiar spatial variation of the Q/1 and U/1 signals observed by CLASP in the hydrogen Ly-alpha line (1216 A) and in the Si Ill line (1206 A) in such a filament channel, it is necessary to perform multi-dimensional radiative transfer modeling. In this contribution, we show the first results of the two-dimensional calculations we are carrying out in given filament models, with the aim of determining the filament thermal and magnetic structure by comparing the theoretical and the observed polarization signals.
Pietra, Stefano; Gustavsson, Anna; Kiefer, Christian; Kalmbach, Lothar; Hörstedt, Per; Ikeda, Yoshihisa; Stepanova, Anna N.; Alonso, Jose M.; Grebe, Markus
2013-01-01
The orientation of cell division and the coordination of cell polarity within the plane of the tissue layer (planar polarity) contribute to shape diverse multicellular organisms. The root of Arabidopsis thaliana displays regularly oriented cell divisions, cell elongation and planar polarity providing a plant model system to study these processes. Here we report that the SABRE protein, which shares similarity with proteins of unknown function throughout eukaryotes, has important roles in orienting cell division and planar polarity. SABRE localizes at the plasma membrane, endomembranes, mitotic spindle and cell plate. SABRE stabilizes the orientation of CLASP-labelled preprophase band microtubules predicting the cell division plane, and of cortical microtubules driving cell elongation. During planar polarity establishment, sabre is epistatic to clasp at directing polar membrane domains of Rho-of-plant GTPases. Our findings mechanistically link SABRE to CLASP-dependent microtubule organization, shedding new light on the function of SABRE-related proteins in eukaryotes. PMID:24240534
Spectro-polarimetric observation in UV with CLASP to probe the chromosphere and transition region
NASA Astrophysics Data System (ADS)
Kano, Ryouhei; Ishikawa, Ryohko; Winebarger, Amy R.; Auchère, Frédéric; Trujillo Bueno, Javier; Narukage, Noriyuki; Kobayashi, Ken; Bando, Takamasa; Katsukawa, Yukio; Kubo, Masahito; Ishikawa, Shin-Nosuke; Giono, Gabriel; Hara, Hirohisa; Suematsu, Yoshinori; Shimizu, Toshifumi; Sakao, Taro; Tsuneta, Saku; Ichimoto, Kiyoshi; Goto, Motoshi; Cirtain, Jonathan W.; De Pontieu, Bart; Casini, Roberto; Manso Sainz, Rafael; Asensio Ramos, Andres; Stepan, Jiri; Belluzzi, Luca; Carlsson, Mats
2016-05-01
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a NASA sounding-rocket experiment that was performed in White Sands in the US on September 3, 2015. During its 5-minute ballistic flight, CLASP successfully made the first spectro-polarimetric observation in the Lyman-alpha line (121.57 nm) originating in the chromosphere and transition region. Since the Lyman-alpha polarization is sensitive to magnetic field of 10-100 G by the Hanle effect, we aim to infer the magnetic field information in such upper solar atmosphere with this experiment.The obtained CLASP data showed that the Lyman-alpha scattering polarization is about a few percent in the wings and the order of 0.1% in the core near the solar limb, as it had been theoretically predicted, and that both polarization signals have a conspicuous spatio-temporal variability. CLASP also observed another upper-chromospheric line, Si III (120.65 nm), whose critical field strength for the Hanle effect is 290 G, and showed a measurable scattering polarization of a few % in this line. The polarization properties of the Si III line could facilitate the interpretation of the scattering polarization observed in the Lyman-alpha line.In this presentation, we would like to show how the upper chromosphere and transition region are seen in the polarization of these UV lines and discuss the possible source of these complicated polarization signals.
Connecting Libraries and Schools with CLASP.
ERIC Educational Resources Information Center
Del Vecchio, Stephen
1993-01-01
Describes the Dewitt Wallace-Reader's Digest Connecting Libraries and Schools Project (CLASP) of the New York Public Library, a cooperative pilot project to encourage reading among children and youth. Sample projects described include summer reading lists, open school night outreach, and outreach to parents. The importance of materials support is…
VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras
NASA Technical Reports Server (NTRS)
Champey, Patrick; Kobayashi, Ken; Winebarger, Amy; Cirtain, Jonathan; Hyde, David; Robertson, Bryan; Beabout, Brent; Beabout, Dyana; Stewart, Mike
2015-01-01
The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.
VUV testing of science cameras at MSFC: QE measurement of the CLASP flight cameras
NASA Astrophysics Data System (ADS)
Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, B.; Beabout, D.; Stewart, M.
2015-08-01
The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint MSFC, National Astronomical Observatory of Japan (NAOJ), Instituto de Astrofisica de Canarias (IAC) and Institut D'Astrophysique Spatiale (IAS) sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512 × 512 detector, dual channel analog readout and an internally mounted cold block. At the flight CCD temperature of -20C, the CLASP cameras exceeded the low-noise performance requirements (<= 25 e- read noise and <= 10 e- /sec/pixel dark current), in addition to maintaining a stable gain of ≍ 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Three flight cameras and one engineering camera were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise and dark current of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV, EUV and X-ray science cameras at MSFC.
NASA Technical Reports Server (NTRS)
Champey, Patrick; Kobayashi, Ken; Winebarger, Amy; Cirtain, Jonathan; Hyde, David; Robertson, Bryan; Beabout, Brent; Beabout, Dyana; Stewart, Mike
2014-01-01
The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro- polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with a gain of 2.0 +/- 0.5, less than or equal to 25 e- readout noise, less than or equal to 10 e-/second/pixel dark current, and less than 0.1percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; system gain, dark current, read noise, and residual non-linearity.
Experimental Estimation of CLASP Spatial Resolution: Results of the Instrument's Optical Alignment
NASA Technical Reports Server (NTRS)
Giono, Gabrial; Katsukawa, Yukio; Ishikawa, Ryoko; Narukage, Noriyuki; Bando, Takamasa; Kano, Ryohei; Suematsu, Yoshinori; Kobayashi, Ken; Winebarger, Amy; Auchere, Frederic
2015-01-01
The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a sounding-rocket experiment currently being built at the National Astronomical Observatory of Japan. This instrument aims to probe for the first time the magnetic field strength and orientation in the solar upper-chromosphere and lower-transition region. CLASP will measure the polarization of the Lyman-Alpha line (121.6nm) with an unprecedented accuracy, and derive the magnetic field information through the Hanle effect. Although polarization accuracy and spectral resolution are crucial for the Hanle effect detection, spatial resolution is also important to get reliable context image via the slit-jaw camera. As spatial resolution is directly related with the alignment of optics, it is also a good way of ensuring the alignment of the instrument to meet the scientific requirement. This poster will detail the experiments carried out to align CLASP's optics (telescope and spectrograph), as both part of the instrument were aligned separately. The telescope was aligned in double-pass mode, and a laser interferometer (He-Ne) was used to measure the telescope's wavefront error (WFE). The secondary mirror tilt and position were adjusted to remove comas and defocus aberrations from the WFE. Effect of gravity on the WFE measurement was estimated and the final WFE derived in zero-g condition for CLASP telescope will be presented. In addition, an estimation of the spot shape and size derived from the final WFE will also be shown. The spectrograph was aligned with a custom procedure: because Ly-??light is absorbed by air, the spectrograph's off-axis parabolic mirrors were aligned in Visible Light (VL) using a custom-made VL grating instead of the flight Ly-? grating. Results of the alignment in Visible Light will be shown and the spot shape recorded with CCDs at various position along the slit will be displayed. Results from both alignment experiment will be compared to the design requirement, and will be combined in order to estimate CLASP spatial resolution after its alignment in visible light.
Immigration Policy's Harmful Impacts on Early Care and Education
ERIC Educational Resources Information Center
Matthews, Hannah; Ullrich, Rebecca; Cervantes, Wendy
2018-01-01
The Center for Law and Social Policy (CLASP) conducted the first ever multi-state study of the effects of the current immigration climate on young children under age 8. In 2017, CLASP interviewed early care and education providers, community-based social service providers, and immigrant parents in six states. The findings, detailed in "Our…
Planning Coverage Campaigns for Mission Design and Analysis: Clasp for the Proposed DESDynI Mission
NASA Technical Reports Server (NTRS)
Knight, Russell; McLaren, David; Hu, Steven
2012-01-01
Mission design and analysis present challenges in that almost all variables are in constant flux, yet the goal is to achieve an acceptable level of performance against a concept of operations, which might also be in flux. To increase responsiveness, our approach is to use automated planning tools that allow for the continual modification of spacecraft, ground system, staffing, and concept of operations while returning metrics that are important to mission evaluation, such as area covered, peak memory usage, and peak data throughput. We have applied this approach to DESDynI (Deformation, Ecosystem Structure, and Dynamics of Ice) mission design concept using the CLASP (Compressed Large-scale Activity Scheduler/Planner) planning system [7], but since this adaptation many techniques have changed under the hood for CLASP and the DESDynI mission concept has undergone drastic changes, including that it has been renamed the Earth Radar Mission. Over the past two years, we have run more than fifty simulations with the CLASP-DESDynI adaptation, simulating different mission scenarios with changing parameters including targets, swaths, instrument modes, and data and downlink rates. We describe the evolution of simulations through the DESDynI MCR (Mission Concept Review) and afterwards.
Pospiech, Peter; Nagel, Florian; Gebhart, Florian; Nothdurft, Frank P; Mitov, Gergo
2012-12-01
The objective of this in vitro study was to investigate the behavior of different composite restorative materials under the load of cast circumferential clasps for removable dental prostheses (RDPs). In 60 human molars, standardized mesial-occlusal-distal cavities were prepared. The cavities were restored with the following materials: Definite, Tetric Ceram, SureFil, Heliomolar RO, Ariston pHc, and Oralloy, and provided with a rest seat. The rest seats were subjected to 5,000 cycles of thermal cycling and 1,200,000 masticatory cycles in a mastication simulator via cobalt-chromium circumferential clasps cast to standardized frameworks in a laboratory model designed to simulate the biomechanics of a free-end denture base. Fracture analysis of the restorations was performed by light microscopy. Before and after loading, material wear was measured with a 3D-laser scanner, and an analysis of the marginal quality was performed in an SEM at ×200 applying the replica technique. No significant differences in the fracture behavior among the composite materials were found; the amalgam control group showed a significantly higher fracture resistance. Regarding the wear of the materials, the composites Definite and SureFil exhibited a behavior similar to that of amalgam. The other composites demonstrated higher wear rates. The initial marginal quality was significantly worse for Ariston pHc. The marginal adaptation decreased significantly after thermal and mechanical loading for Definite and Ariston pHc. In terms of the investigated aspects of mechanical performance, the tested composites seemed to be inferior to amalgam. Further clinical studies are needed to evaluate the ability of composite restorations to provide support for RDP clasps. The use of composites as direct restoration materials should be avoided in teeth, which serve as abutments for clasp-retained RDPs.
Ly-alpha polarimeter design for CLASP rocket experiment
NASA Astrophysics Data System (ADS)
Kubo, M.; Watanabe, H.; Narukage, N.; Ishikawa, R.; Bando, T.; Kano, R.; Tsuneta, S.; Kobayashi, K.; Ichimoto, K.; Trujillo Bueno, J.; Song, D.
2011-12-01
A sounding-rocket program called the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is proposed to be launched in the Summer of 2014. CLASP will observe the upper solar chromosphere in Ly-alpha (121.567 nm), aiming to detect the linear polarization signal produced by scattering processes and the Hanle effect for the first time. The CLASP needs a rotating half-waveplate and a polarization analyzer working at the Ly-alpha wavelength to measure the linear polarization signal. We select Magnesium Fluoride (MgF2) as a material of the optical components because of its birefringent property and high transparency at UV wavelength. We have confirmed that the reflection at the Brewster's Angle of MgF2 plate is a good polarization analyzer for the Ly-alpha line by deriving its ordinary refractive index and extinction coefficient along the ordinary and extraordinary axes. These optical parameters are calculated with a least-square fitting in such a way that the reflectance and transmittance satisfy the Kramers-Kronig relation. The reflectance and transmittance against oblique incident angles for the s-polarized and the p-polarized light are measured using the synchrotron beamline at the Ultraviolet Synchrotron Orbital Radiation Facility (UVSOR). We have also measured a retardation of a zeroth-order waveplate made of MgF2. The thickness difference of the waveplate is 14.57 um.This waveplate works as a half-waveplate at 121.74 nm. From this measurement, we estimate that a waveplate with the thickness difference of 15.71 um will work as a half-waveplate at the Ly-alpha wavelength. We have developed a rotating waveplate - polarization analyzer system called a prototype of CLASP polarimeter, and input the perfect Stokes Q and U signals. The modulation patterns that are consistent with the theoretical prediction are successfully obtained in both cases.
Sixteen years of collaborative learning through active sense-making in physics (CLASP) at UC Davis
NASA Astrophysics Data System (ADS)
Potter, Wendell; Webb, David; Paul, Cassandra; West, Emily; Bowen, Mark; Weiss, Brenda; Coleman, Lawrence; De Leone, Charles
2014-02-01
This paper describes our large reformed introductory physics course at UC Davis, which bioscience students have been taking since 1996. The central feature of this course is a focus on sense-making by the students during the 5 h per week discussion/labs in which the students take part in activities emphasizing peer-peer discussions, argumentation, and presentations of ideas. The course differs in many fundamental ways from traditionally taught introductory physics courses. After discussing the unique features of CLASP and its implementation at UC Davis, various student outcome measures are presented that show increased performance by students who took the CLASP course compared to students who took a traditionally taught introductory physics course. Measures we use include upper-division GPAs, MCAT scores, FCI gains, and MPEX-II scores.
ERIC Educational Resources Information Center
Harris, Linda; Tsoi-A-Fatt, Rhonda
2007-01-01
This paper presents Center for Law and Social Policy's (CLASP's) recommendations on how No Child Left Behind (NCLB) could better address the workforce challenges faced by this country. CLASP is a nonprofit organization engaged in research, analysis, technical assistance, and advocacy on a range of issues affecting low-income families. The…
Rodrigues, Renata Cristina Silveira; Ribeiro, Ricardo Faria; de Mattos, Maria da Gloria Chiarello; Bezzon, Osvaldo Luiz
2002-09-01
The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies to support its use. The objective of this study was to compare circumferential RPD clasps made of commercially pure titanium and identical clasps made of 2 different cobalt (Co)-chromium (Cr) alloys by testing insertion/removal and radiographically inspecting the casts for defects. On refractory casts that represent a partially edentulous mandibular right hemi-arch segment, 36 frameworks were cast from commercially pure titanium (n = 12) and 2 Co-Cr alloys (n = 12 each) with identical prefabricated patterns and the manufacturer-designated investment and casting technique. Each group was divided into 2 subgroups, corresponding to .25-mm and .50-mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. Only nodules and burs were carefully removed with tungsten burs under magnification when necessary. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. The data were subjected to analysis of variance and the Tukey complementary test (P<.01) to compare the retentive forces of RPDs made with the different materials. The Student t test (P<.01) was used to compare the retentive forces of RPDs fabricated with the same alloy with different undercuts. A total of 20% of the titanium specimens demonstrated porosity, showing casting difficulties, and any defect detected on the clasps determined the sample replacement. For Co-Cr alloys, casting difficulties were not found. The data were subjected to analysis of variance and the Tukey complementary test to compare materials for the same undercut. For the .25-mm undercut, no significant difference was found between Magnum and Rematitan alloys; they were both different from the Remanium alloy (P<.01). For the.50-mm undercut, no significant difference was found between Co-Cr alloys; they were both different from Rematitan alloy (P<.01). The Student t test used to compare the same alloys with different undercuts showed no significant difference between Remanium with .25-mm and .50-mm undercuts. For Magnum and Rematitan alloys, there was a significant difference between different undercuts (P=.01). Within the limitations of this simulation study, the results suggest that commercially pure titanium clasps maintained retention over a simulated 5-year period, with lower retention force than identical Co-Cr clasps.
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)
NASA Technical Reports Server (NTRS)
Ishikawa, Shin-nosuke; Kano, R.; Kobayashi, K.; Bando, T.; Narukage, N..; Ishikawa, R.; Kubo, M.; Katsukawa, Y.; Suematsu, Y.; Hara, H.;
2014-01-01
To Understand energy release process in the Sun including solar flares, it is essentially important to measure the magnetic field of the atmosphere of the Sun. Magnetic field measurement of the upper layers (upper chromosphere and above) was technically difficult and not well investigated yet. Upper chromosphere and transition region magnetic field measurement by Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) sounding rocket to be launched in 2015. The proposal is already selected and developments of the flight components are going.
Chromospheric Lyman-alpha spectro-polarimeter (CLASP)
NASA Astrophysics Data System (ADS)
Kano, Ryouhei; Bando, Takamasa; Narukage, Noriyuki; Ishikawa, Ryoko; Tsuneta, Saku; Katsukawa, Yukio; Kubo, Masahito; Ishikawa, Shin-nosuke; Hara, Hirohisa; Shimizu, Toshifumi; Suematsu, Yoshinori; Ichimoto, Kiyoshi; Sakao, Taro; Goto, Motoshi; Kato, Yoshiaki; Imada, Shinsuke; Kobayashi, Ken; Holloway, Todd; Winebarger, Amy; Cirtain, Jonathan; De Pontieu, Bart; Casini, Roberto; Trujillo Bueno, Javier; Štepán, Jiří; Manso Sainz, Rafael; Belluzzi, Luca; Asensio Ramos, Andres; Auchère, Frédéric; Carlsson, Mats
2012-09-01
One of the biggest challenges in heliophysics is to decipher the magnetic structure of the solar chromosphere. The importance of measuring the chromospheric magnetic field is due to both the key role the chromosphere plays in energizing and structuring the outer solar atmosphere and the inability of extrapolation of photospheric fields to adequately describe this key boundary region. Over the last few years, significant progress has been made in the spectral line formation of UV lines as well as the MHD modeling of the solar atmosphere. It is found that the Hanle effect in the Lyman-alpha line (121.567 nm) is a most promising diagnostic tool for weaker magnetic fields in the chromosphere and transition region. Based on this groundbreaking research, we propose the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) to NASA as a sounding rocket experiment, for making the first measurement of the linear polarization produced by scattering processes and the Hanle effect in the Lyman-alpha line (121.567 nm), and making the first exploration of the magnetic field in the upper chromosphere and transition region of the Sun. The CLASP instrument consists of a Cassegrain telescope, a rotating 1/2-wave plate, a dual-beam spectrograph assembly with a grating working as a beam splitter, and an identical pair of reflective polarization analyzers each equipped with a CCD camera. We propose to launch CLASP in December 2014.
NASA Astrophysics Data System (ADS)
Walker, S. C.; Rachmeler, L.; Winebarger, A. R.; Champey, P. R.; Bethge, C.
2017-12-01
To unveil the complexity of the solar atmosphere, measurement of the magnetic field in the upper chromosphere and transition region is fundamentally important, as this is where the forces transition from plasma to magnetic field dominated. Measurements of the field are also needed to shed light on the energy transport from the lower atmospheric regions to the corona beyond. Such an advance in heliospheric knowledge became possible with the first flight of the international solar sounding rocket mission, CLASP. For the first time, linear polarization was measured in H Lyman-Alpha at 121.60 nm in September 2015. For linear polarization measurements in this line, high sensitivity is required due to the relatively weak polarization signal compared to the intensity. To achieve this high sensitivity, a low-noise sensor is required with good knowledge of its characterization, including linearity. This work presents further refinement of the linearity characterization of the cameras flown in 2015. We compared the current from a photodiode in the light path to the digital response of the detectors. Pre-flight CCD linearity measurements were taken for all three flight cameras and calculations of the linear fits and residuals were performed. However, the previous calculations included a smearing pattern and a digital saturation region on the detectors which were not properly taken into account. The calculations have been adjusted and were repeated for manually chosen sub-regions on the detectors that were found not to be affected. We present a brief overview of the instrument, the calibration data and procedures, and a comparison of the old and new linearity results. The CLASP cameras will be reused for the successor mission, CLASP2, which will measure the Mg II h & k lines between 279.45 nm and 280.35 nm. The new approach will help to better prepare for and to improve the camera characterization for CLASP2.
Chakraborty, Sandeep; Minda, Renu; Salaye, Lipika; Bhattacharjee, Swapan K.; Rao, Basuthkar J.
2011-01-01
Computational methods are increasingly gaining importance as an aid in identifying active sites. Mostly these methods tend to have structural information that supplement sequence conservation based analyses. Development of tools that compute electrostatic potentials has further improved our ability to better characterize the active site residues in proteins. We have described a computational methodology for detecting active sites based on structural and electrostatic conformity - C ata L ytic A ctive S ite P rediction (CLASP). In our pipelined model, physical 3D signature of any particular enzymatic function as defined by its active sites is used to obtain spatially congruent matches. While previous work has revealed that catalytic residues have large pKa deviations from standard values, we show that for a given enzymatic activity, electrostatic potential difference (PD) between analogous residue pairs in an active site taken from different proteins of the same family are similar. False positives in spatially congruent matches are further pruned by PD analysis where cognate pairs with large deviations are rejected. We first present the results of active site prediction by CLASP for two enzymatic activities - β-lactamases and serine proteases, two of the most extensively investigated enzymes. The results of CLASP analysis on motifs extracted from Catalytic Site Atlas (CSA) are also presented in order to demonstrate its ability to accurately classify any protein, putative or otherwise, with known structure. The source code and database is made available at www.sanchak.com/clasp/. Subsequently, we probed alkaline phosphatases (AP), one of the well known promiscuous enzymes, for additional activities. Such a search has led us to predict a hitherto unknown function of shrimp alkaline phosphatase (SAP), where the protein acts as a protease. Finally, we present experimental evidence of the prediction by CLASP by showing that SAP indeed has protease activity in vitro. PMID:22174814
NASA Technical Reports Server (NTRS)
Walker, Salma C.; Rachmeler, Laurel; Winebarger, Amy; Champey, Patrick; Bethge, Christian
2017-01-01
To unveil the complexity of the solar atmosphere, measurement of the magnetic field in the upper chromosphere and transition region is fundamentally important, as this is where the forces transition from plasma to magnetic field dominated. Measurements of the field are also needed to elucidate the energy transport from the lower atmospheric regions to the corona beyond. Such an advance in heliospheric knowledge became possible with the first flight of the international solar sounding rocket mission, CLASP. For the first time, linear polarization was measured in Hydrogen Lyman-Alpha at 121.60 nm in September 2015. For linear polarization measurements in this emission line, high sensitivity is required due to the relatively weak polarization signal compared to the intensity. To achieve this high sensitivity, a low-noise sensor is required with good knowledge of its characterization, including linearity. This work presents further refinement of the linearity characterization of the cameras flown in 2015. We compared the current from a photodiode in the light path to the digital response of the detectors. Pre-flight CCD linearity measurements were taken for all three flight cameras and calculations of the linear fits and residuals were performed. However, the previous calculations included a smearing pattern and a digital saturation region on the detectors which were not properly taken into account. The calculations have been adjusted and were repeated for manually chosen sub-regions on the detectors that were found not to be affected. We present a brief overview of the instrument, the calibration data and procedures, and a comparison of the old and new linearity results. The CLASP cameras will be reused for the successor mission, CLASP2, which will measure the Magnesium II h & k emission lines between 279.45 nm and 280.35 nm. The new approach will help to better prepare for and to improve the camera characterization for CLASP2.
NASA Technical Reports Server (NTRS)
Walker, Salma C.; Rachmeler, Laurel; Winebarger, Amy; Champey, Patrick; Bethge, Christian
2018-01-01
To unveil the complexity of the solar atmosphere, measurement of the magnetic field in the upper chromosphere and transition region is fundamentally important, as this is where the forces transition from plasma to magnetic field dominated. Measurements of the field are also needed to elucidate the energy transport from the lower atmospheric regions to the corona beyond. Such an advance in heliospheric knowledge became possible with the first flight of the international solar sounding rocket mission, CLASP. For the first time, linear polarization was measured in Hydrogen Lyman-Alpha at 121.60 nm in September 2015. For linear polarization measurements in this emission line, high sensitivity is required due to the relatively weak polarization signal compared to the intensity. To achieve this high sensitivity, a low-noise sensor is required with good knowledge of its characterization, including linearity. This work presents further refinement of the linearity characterization of the cameras flown in 2015. We compared the current from a photodiode in the light path to the digital response of the detectors. Pre-flight CCD linearity measurements were taken for all three flight cameras and calculations of the linear fits and residuals were performed. However, the previous calculations included a smearing pattern and a digital saturation region on the detectors which were not properly taken into account. The calculations have been adjusted and were repeated for manually chosen sub-regions on the detectors that were found not to be affected. We present a brief overview of the instrument, the calibration data and procedures, and a comparison of the old and new linearity results. The CLASP cameras will be reused for the successor mission, CLASP2, which will measure the Magnesium II h & k emission lines between 279.45 nm and 280.35 nm. The new approach will help to better prepare for and to improve the camera characterization for CLASP2.
Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP)
NASA Technical Reports Server (NTRS)
Kano, Ryohei; Bando, Takamasa; Narukage, Noriyuki; Ishikawa, Ryoko; Kubo, Masahito; Katsukawa, Yukio; Ishikawa, Shin-nosuke; Hara, Hirohisa; Suematsu, Yoshinori; Giono, Gabriel;
2015-01-01
Chromosphere, the transition layer of the sun is a region to switch to the magnetic pressure dominated from plasma pressure dominated, simultaneous observation of the detailed magnetic field measurement and plasma of dynamic phenomenon here is what is the frontier of the next solar physics. As This is a challenge that has just mentioned, even the next solar observation satellite plan SOLAR-C, in the experiments we had used a NASA sounding rocket for the first time in the SOLAR-C plan, will address the chromosphere-transition layer magnetic field measurement there. It is, is a Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) plan, the linear polarization of Lyman ?? emission lines chromosphere-transition layer shoots (121.6nm) were detected in 0.1 percent of high accuracy, a new technique called Hanre effect I get the magnetic field information of chromosphere-transition layer. In Japan, the US and Europe joint observation in November 2012 as a rocket experiment is adopted to NASA this plan that full-scale start-up, start from assembly work is 2014 spring flight observation device, currently, it is where the alignment of the optical elements have been implemented. After this, it is planned to continue with the performance evaluation towards the observation implementation of summer 2015. In addition to once again explain the contents of the plan In this presentation, we report an overview of the entire development and preparation current status.
MTCL1 crosslinks and stabilizes non-centrosomal microtubules on the Golgi membrane.
Sato, Yoshinori; Hayashi, Kenji; Amano, Yoshiko; Takahashi, Mikiko; Yonemura, Shigenobu; Hayashi, Ikuko; Hirose, Hiroko; Ohno, Shigeo; Suzuki, Atsushi
2014-11-04
Recent studies have revealed the presence of a microtubule subpopulation called Golgi-derived microtubules that support Golgi ribbon formation, which is required for maintaining polarized cell migration. CLASPs and AKAP450/CG-NAP are involved in their formation, but the underlying molecular mechanisms remain unclear. Here, we find that the microtubule-crosslinking protein, MTCL1, is recruited to the Golgi membranes through interactions with CLASPs and AKAP450/CG-NAP, and promotes microtubule growth from the Golgi membrane. Correspondingly, MTCL1 knockdown specifically impairs the formation of the stable perinuclear microtubule network to which the Golgi ribbon tethers and extends. Rescue experiments demonstrate that besides its crosslinking activity mediated by the N-terminal microtubule-binding region, the C-terminal microtubule-binding region plays essential roles in these MTCL1 functions through a novel microtubule-stabilizing activity. These results suggest that MTCL1 cooperates with CLASPs and AKAP450/CG-NAP in the formation of the Golgi-derived microtubules, and mediates their development into a stable microtubule network.
Clasp/SJ Observation of Time Variations of Lyman-Alpha Emissions in a Solar Active Region
NASA Technical Reports Server (NTRS)
Ishikawa, S.; Kubo, M.; Katsukawa, Y.; Kano, R.; Narukage, N.; Ishikawa, R.; Bando, T.; Winebarger, A.; Kobayashi, K.; Trujillo Bueno, J.;
2016-01-01
The Chromospheric Lyman-alpha SpectroPolarimeter (CLASP) is a sounding rocket experiment launched on September 3, 2015 to investigate the solar chromosphere, and the slit-jaw (SJ) optical system took Lya images with the high time cadence of 0.6 s. By the CLASP/SJ observation, many time variations in the solar chromosphere with the time scale of <1 minute were discovered (see the poster by Kubo et al., Pa-13). We focused on an active region and investigated the short (<30 s) time variations and relation to the coronal structure observed by SDO/AIA. We compared the Ly(alpha) time variations at footpoints of coronal magnetic fields observed by AIA 211 Å (approx.2 MK) and AIA 171 Å (0.6 MK), and non-loop regions. As the result, we found the <30 s Ly(alpha) time variations had more in the footpoint regions. On the other hand, the <30 s time variations had no dependency on the temperature of the loop.
NASA Astrophysics Data System (ADS)
Ishikawa, Ryohko; Kano, Ryouhei; Winebarger, Amy; Auchere, Frederic; Trujillo Bueno, Javier; Bando, Takamasa; Narukage, Noriyuki; Kobayashi, Ken; Katsukawa, Yukio; Kubo, Masahito; Ishikawa, Shin-nosuke; Giono, Gabriel; Tsuneta, Saku; Hara, Hirohisa; Suematsu, Yoshinori; Shimizu, Toshifumi; Sakao, Taro; Ichimoto, Kiyoshi; Cirtain, Jonathan; De Pontieu, Bart; Casini, Roberto; Manso Sainz, Rafael; Asensio Ramos, Andres; Stepan, Jiri; Belluzzi, Luca
2015-08-01
The wish to understand the energetic phenomena of the outer solar atmosphere makes it increasingly important to achieve quantitative information on the magnetic field in the chromosphere-corona transition region. To this end, we need to measure and model the linear polarization produced by scattering processes and the Hanle effect in strong UV resonance lines, such as the hydrogen Lyman-alpha line. A team consisting of Japan, USA, Spain, France, and Norway has been developing a sounding rocket experiment called the Chromospheric Lyman-alpha Spectro-Polarimeter (CLASP). The aim is to detect the scattering polarization produced by anisotropic radiation pumping in the hydrogen Lyman-alpha line (121.6 nm), and via the Hanle effect to try to constrain the magnetic field vector in the upper chromosphere and transition region. In this talk, we will present an overview of our CLASP mission, its scientific objectives, ground tests made, and the latest information on the launch planned for the Summer of 2015.
NASA Astrophysics Data System (ADS)
Kubo, M.; Katsukawa, Y.; Suematsu, Y.; Kano, R.; Bando, T.; Narukage, N.; Ishikawa, R.; Hara, H.; Giono, G.; Tsuneta, S.; Ishikawa, S.; Shimizu, T.; Sakao, T.; Winebarger, A.; Kobayashi, K.; Cirtain, J.; Champey, P.; Auchère, F.; Trujillo Bueno, J.; Asensio Ramos, A.; Štěpán, J.; Belluzzi, L.; Manso Sainz, R.; De Pontieu, B.; Ichimoto, K.; Carlsson, M.; Casini, R.; Goto, M.
2016-12-01
High-cadence observations by the slit-jaw (SJ) optics system of the sounding rocket experiment known as the Chromospheric Lyman Alpha Spectropolarimeter (CLASP) reveal ubiquitous intensity disturbances that recurrently propagate in either the chromosphere or the transition region or both at a speed much higher than the speed of sound. The CLASP/SJ instrument provides a time series of two-dimensional images taken with broadband filters centered on the Lyα line at a 0.6 s cadence. The multiple fast-propagating intensity disturbances appear in the quiet Sun and in an active region, and they are clearly detected in at least 20 areas in a field of view of 527″ × 527″ during the 5 minute observing time. The apparent speeds of the intensity disturbances range from 150 to 350 km s-1, and they are comparable to the local Alfvén speed in the transition region. The intensity disturbances tend to propagate along bright elongated structures away from areas with strong photospheric magnetic fields. This suggests that the observed fast-propagating intensity disturbances are related to the magnetic canopy structures. The maximum distance traveled by the intensity disturbances is about 10″, and the widths are a few arcseconds, which are almost determined by a pixel size of 1.″03. The timescale of each intensity pulse is shorter than 30 s. One possible explanation for the fast-propagating intensity disturbances observed by CLASP is magnetohydrodynamic fast-mode waves.
NASA Technical Reports Server (NTRS)
Kubo, M.; Katsukawa, Y.; Suematsu, Y.; Kano, R.; Bando, T.; Narukage, N.; Ishikawa, R.; Hara, H.; Giono, G.; Tsuneta, S.;
2016-01-01
High cadence observations by the slit-jaw (SJ) optics system of the sounding rocket experiment known as the Chromospheric Lyman Alpha SpectroPolarimeter (CLASP) reveal ubiquitous intensity disturbances that recurrently propagate in one or both of the chromosphere or transition region at a speed much higher than the sound speed. The CLASP/SJ instrument provides a time series of 2D images taken with broadband filters centered on the Ly(alpha) line at a 0.6 s cadence. The fast propagating intensity disturbances are detected in the quiet Sun and in an active region, and at least 20 events are clearly detected in the field of view of 527'' x 527'' during the 5-minute observing time. The apparent speeds of the intensity disturbances range from 150 to 350 km/s, and they are comparable to the local Alfven speed in the transition region. The intensity disturbances tend to propagate along bright elongated structures away from areas with strong photospheric magnetic fields. This suggests that the observed propagating intensity disturbances are related to the magnetic canopy structures. The maximum distance traveled by the intensity disturbances is of about 10'', and the widths are a few arcseconds, which is almost determined by the pixel size of 1.''03. The timescale of each intensity pulse is shorter than 30 s. One possible explanation of the fast propagating intensity disturbances observed by CLASP is magneto-hydrodynamic fast mode waves.
NASA Technical Reports Server (NTRS)
1980-01-01
NASA developed personal security system, commercialized by Sentry Products, Inc. enables resident to summon instant help in case of medical emergency or threatened violence. Its principal elements are a pen-shaped signaling device, "silent" because its ultrasonic alert signal is inaudible to the human ear, and a system of receivers interconnected with a constantly-monitored aster console. SCAN pen weighs only two ounces and is worn on necklace or attached by a clip to the user's clothing. The person in trouble simply presses a clasp, releasing a hammer inside the pen which strikes an aluminum bar. The impact causes the bar to resonate like a tuning fork and emit the ultrasonic signal, which is detected by the nearest receiver.
Vocal communication between male Xenopus laevis.
Tobias, Martha L; Barnard, Candace; O'Hagan, Robert; Horng, Sam H; Rand, Masha; Kelley, Darcy B
2004-02-01
This study focuses on the role of male-male vocal communication in the reproductive repertoire of the South African clawed frog, Xenopus laevis . Six male and two female call types were recorded from native ponds in the environs of Cape Town, South Africa. These include all call types previously recorded in the laboratory as well as one previously unidentified male call: chirping. The amount of calling and the number of call types increased as the breeding season progressed. Laboratory recordings indicated that all six male call types were directed to males; three of these were directed to both sexes and three were directed exclusively to males. Both female call types were directed exclusively to males. The predominant call type, in both field and laboratory recordings, was the male advertisement call. Sexual state affected male vocal behaviour. Male pairs in which at least one male was sexually active (gonadotropin injected) produced all call types, whereas pairs of uninjected males rarely called. Some call types were strongly associated with a specific behaviour and others were not. Clasped males always growled and clasping males typically produced amplectant calls or chirps; males not engaged in clasping most frequently advertised. The amount of advertising produced by one male was profoundly affected by the presence of another male. Pairing two sexually active males resulted in suppression of advertisement calling in one; suppression was released when males were isolated after pairing. Vocal dominance was achieved even in the absence of physical contact (clasping). We suggest that X. laevis males gain a reproductive advantage by competing for advertisement privileges and by vocally suppressing neighbouring males.
Grallert, Agnes; Beuter, Christoph; Craven, Rachel A.; Bagley, Steve; Wilks, Deepti; Fleig, Ursula; Hagan, Iain M.
2006-01-01
The Schizosaccharomyces pombe CLIP170-associated protein (CLASP) Peg1 was identified in a screen for mutants with spindle formation defects and a screen for molecules that antagonized EB1 function. The conditional peg1.1 mutant enabled us to identify key features of Peg1 function. First, Peg1 was required to form a spindle and astral microtubules, yet destabilized interphase microtubules. Second, Peg1 was required to slow the polymerization rate of interphase microtubules that establish end-on contact with the cortex at cell tips. Third, Peg1 antagonized the action of S. pombe CLIP170 (Tip1) and EB1 (Mal3). Fourth, although Peg1 resembled higher eukaryotic CLASPs by physically associating with both Mal3 and Tip1, neither Tip1 nor Mal3 was required for Peg1 to destabilize interphase microtubules or for it to associate with microtubules. Conversely, neither Mal3 nor Tip1 required Peg1 to associate with microtubules or cell tips. Consistently, while mal3.Δ and tip1.Δ disrupted linear growth, corrupting peg1 + did not. Fifth, peg1.1 phenotypes resembled those arising from deletion of the single heavy or both light chains of fission yeast dynein. Furthermore, all interphase phenotypes arising from peg1 + manipulation relied on dynein function. Thus, the impact of S. pombe CLASP on interphase microtubule behavior is more closely aligned to dynein than EB1 or CLIP170. PMID:16951255
GSK3 controls axon growth via CLASP-mediated regulation of growth cone microtubules
Hur, Eun-Mi; Saijilafu; Lee, Byoung Dae; Kim, Seong-Jin; Xu, Wen-Lin; Zhou, Feng-Quan
2011-01-01
Suppression of glycogen synthase kinase 3 (GSK3) activity in neurons yields pleiotropic outcomes, causing both axon growth promotion and inhibition. Previous studies have suggested that specific GSK3 substrates, such as adenomatous polyposis coli (APC) and collapsin response mediator protein 2 (CRMP2), support axon growth by regulating the stability of axonal microtubules (MTs), but the substrate(s) and mechanisms conveying axon growth inhibition remain elusive. Here we show that CLIP (cytoplasmic linker protein)-associated protein (CLASP), originally identified as a MT plus end-binding protein, displays both plus end-binding and lattice-binding activities in nerve growth cones, and reveal that the two MT-binding activities regulate axon growth in an opposing manner: The lattice-binding activity mediates axon growth inhibition induced by suppression of GSK3 activity via preventing MT protrusion into the growth cone periphery, whereas the plus end-binding property supports axon extension via stabilizing the growing ends of axonal MTs. We propose a model in which CLASP transduces GSK3 activity levels to differentially control axon growth by coordinating the stability and configuration of growth cone MTs. PMID:21937714
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, S.M.; Pampa, K.J.; Manjula, M.
2014-06-20
Highlights: • We determined the structure of isocitrate dehydrogenase with citrate and cofactor. • The structure reveals a unique novel terminal domain involved in dimerization. • Clasp domain shows significant difference, and catalytic residues are conserved. • Oligomerization of the enzyme is quantized with subunit-subunit interactions. • Novel domain of this enzyme is classified as subfamily of the type IV. - Abstract: NADP{sup +} dependent isocitrate dehydrogenase (IDH) is an enzyme catalyzing oxidative decarboxylation of isocitrate into oxalosuccinate (intermediate) and finally the product α-ketoglutarate. The crystal structure of Thermus thermophilus isocitrate dehydrogenase (TtIDH) ternary complex with citrate and cofactor NADP{supmore » +} was determined using X-ray diffraction method to a resolution of 1.80 Å. The overall fold of this protein was resolved into large domain, small domain and a clasp domain. The monomeric structure reveals a novel terminal domain involved in dimerization, very unique and novel domain when compared to other IDH’s. And, small domain and clasp domain showing significant differences when compared to other IDH’s of the same sub-family. The structure of TtIDH reveals the absence of helix at the clasp domain, which is mainly involved in oligomerization in other IDH’s. Also, helices/beta sheets are absent in the small domain, when compared to other IDH’s of the same sub family. The overall TtIDH structure exhibits closed conformation with catalytic triad residues, Tyr144-Asp248-Lys191 are conserved. Oligomerization of the protein is quantized using interface area and subunit–subunit interactions between protomers. Overall, the TtIDH structure with novel terminal domain may be categorized as a first structure of subfamily of type IV.« less
Discovery of Short-Timescale Oscillations in the Transition Region by CLASP
NASA Technical Reports Server (NTRS)
Kubo, M.; Katsukawa, Y.; Kano, R.; Winebarger, A.; Kobayashi, K.; Ishikawa, R.; Narukage, N.; Bando, T.; Suematsu, Y.; Giono, G.;
2017-01-01
High cadence spectroscopic observations by CLASP reveal that intensity fluctuations of blue and red peaks of the hydrogen Lyman-alpha line (121.57 nm) recurrently appear in the quiet Sun at short timescale. The intensity fluctuations of the blue and red peaks are opposite in phase to each other: the blue peak is enhanced during the decease of the red peak, and vice versa. Similar intensity fluctuations also can be seen in Mg II h & k profiles observed with IRIS. It is suggested that the short-timescale oscillatory or torsional phenomena take place in the transition region or the upper chromosphere.
Hattori, Takamitsu; Lai, Darson; Dementieva, Irina S.; ...
2016-02-09
Antibodies have a well-established modular architecture wherein the antigen-binding site residing in the antigen-binding fragment (Fab or Fv) is an autonomous and complete unit for antigen recognition. Here, we describe antibodies departing from this paradigm. We developed recombinant antibodies to trimethylated lysine residues on histone H3, important epigenetic marks and challenging targets for molecular recognition. Quantitative characterization demonstrated their exquisite specificity and high affinity, and they performed well in common epigenetics applications. Surprisingly, crystal structures and biophysical analyses revealed that two antigen-binding sites of these antibodies form a head-to-head dimer and cooperatively recognize the antigen in the dimer interface. Thismore » “antigen clasping” produced an expansive interface where trimethylated Lys bound to an unusually extensive aromatic cage in one Fab and the histone N terminus to a pocket in the other, thereby rationalizing the high specificity. A long-neck antibody format with a long linker between the antigen-binding module and the Fc region facilitated antigen clasping and achieved both high specificity and high potency. Antigen clasping substantially expands the paradigm of antibody–antigen recognition and suggests a strategy for developing extremely specific antibodies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hattori, Takamitsu; Lai, Darson; Dementieva, Irina S.
Antibodies have a well-established modular architecture wherein the antigen-binding site residing in the antigen-binding fragment (Fab or Fv) is an autonomous and complete unit for antigen recognition. Here, we describe antibodies departing from this paradigm. We developed recombinant antibodies to trimethylated lysine residues on histone H3, important epigenetic marks and challenging targets for molecular recognition. Quantitative characterization demonstrated their exquisite specificity and high affinity, and they performed well in common epigenetics applications. Surprisingly, crystal structures and biophysical analyses revealed that two antigen-binding sites of these antibodies form a head-to-head dimer and cooperatively recognize the antigen in the dimer interface. Thismore » “antigen clasping” produced an expansive interface where trimethylated Lys bound to an unusually extensive aromatic cage in one Fab and the histone N terminus to a pocket in the other, thereby rationalizing the high specificity. A long-neck antibody format with a long linker between the antigen-binding module and the Fc region facilitated antigen clasping and achieved both high specificity and high potency. Antigen clasping substantially expands the paradigm of antibody–antigen recognition and suggests a strategy for developing extremely specific antibodies.« less
Pheromones enhance somatosensory processing in newt brains through a vasotocin-dependent mechanism.
Thompson, R R; Dickinson, P S; Rose, J D; Dakin, K A; Civiello, G M; Segerdahl, A; Bartlett, R
2008-07-22
We tested whether the sex pheromones that stimulate courtship clasping in male roughskin newts do so, at least in part, by amplifying the somatosensory signals that directly trigger the motor pattern associated with clasping and, if so, whether that amplification is dependent on endogenous vasotocin (VT). Female olfactory stimuli increased the number of action potentials recorded in the medulla of males in response to tactile stimulation of the cloaca, which triggers the clasp motor reflex, as well as to tactile stimulation of the snout and hindlimb. That enhancement was blocked by exposing the medulla to a V1a receptor antagonist before pheromone exposure. However, the antagonist did not affect medullary responses to tactile stimuli in the absence of pheromone exposure, suggesting that pheromones amplify somatosensory signals by inducing endogenous VT release. The ability of VT to couple sensory systems together in response to social stimulation could allow this peptide to induce variable behavioural outcomes, depending on the immediate context of the social interaction and thus on the nature of the associated stimuli that are amplified. If widespread in vertebrates, this mechanism could account for some of the behavioural variability associated with this and related peptides both within and across species.
Planning Coverage Campaigns for Mission Design and Analysis: CLASP for DESDynl
NASA Technical Reports Server (NTRS)
Knight, Russell L.; McLaren, David A.; Hu, Steven
2013-01-01
Mission design and analysis presents challenges in that almost all variables are in constant flux, yet the goal is to achieve an acceptable level of performance against a concept of operations, which might also be in flux. To increase responsiveness, automated planning tools are used that allow for the continual modification of spacecraft, ground system, staffing, and concept of operations, while returning metrics that are important to mission evaluation, such as area covered, peak memory usage, and peak data throughput. This approach was applied to the DESDynl mission design using the CLASP planning system, but since this adaptation, many techniques have changed under the hood for CLASP, and the DESDynl mission concept has undergone drastic changes. The software produces mission evaluation products, such as memory highwater marks, coverage percentages, given a mission design in the form of coverage targets, concept of operations, spacecraft parameters, and orbital parameters. It tries to overcome the lack of fidelity and timeliness of mission requirements coverage analysis during mission design. Previous techniques primarily use Excel in ad hoc fashion to approximate key factors in mission performance, often falling victim to overgeneralizations necessary in such an adaptation. The new program allows designers to faithfully represent their mission designs quickly, and get more accurate results just as quickly.
NASA Technical Reports Server (NTRS)
Katsukawa, Yukio; Ishikawa, Ryoko; Kano, Ryohei; Kubo, Masahito; Noriyuki, Narukage; Kisei, Bando; Hara, Hirohisa; Yoshiho, Suematsu; Goto, Motouji; Ishikawa, Shinnosuke;
2017-01-01
The CLASP (Chromospheric Lyman-Alpha Spectro- Polarimeter) rocket experiment, in addition to the ultraviolet region of the Ly alpha emission line (121.57 nm), emission lines of Si III (120.65 nm) and OV (121.83 nm) is can be observed. These are optically thin line compared to a Ly alpha line, if Rarere captured its polarization, there is a possibility that dripping even a new physical diagnosis chromosphere-transition layer. In particular, OV bright light is a release from the transition layer, further, three P one to one S(sub 0) is a forbidden line (cross-triplet transition between lines), it was not quite know whether to polarization.
Three petabytes or bust: planning science observations for NISAR
NASA Astrophysics Data System (ADS)
Doubleday, Joshua R.
2016-05-01
The National Aeronautics and Space Administration (NASA) and the Indian Space Research Organization (ISRO) have formed a joint agency mission, NASA ISRO Synthetic Aperture Radar (NISAR) to fly in the 2020 timeframe, charged with collecting Synthetic Aperture Radar data over nearly all of earth's land and ice, to advance science in ecosystems, solid-earth and cryospheric disciplines with global time-series maps of various phenomenon. Over a three-year mission span, NISAR will collect on the order of 24 Terabits of raw radar data per day. Developing a plan to collect the data necessary for these three primary science disciplines and their sub-disciplines has been challenging in terms of overlapping geographic regions of interest, temporal requirements, competing modes of the radar instrument, and data-volume resources. One of the chief tools in building a plan of observations against these requirements has been a software tool developed at JPL, the Compressed Large-scale Scheduler Planner (CLASP). CLASP intersects the temporo-geometric visibilities of a spaceborne instrument with campaigns of temporospatial maps of scientific interest, in an iterative squeaky-wheel optimization loop. While the overarching strategy for science observations has evolved through the formulation phases of this mission, so has the use of CLASP. We'll show how this problem space and tool has evolved over time, as well as some of the current parameter estimates for NISAR and its overall mission plan.
Development of a Precise Polarization Modulator for UV Spectropolarimetry
NASA Astrophysics Data System (ADS)
Ishikawa, S.; Shimizu, T.; Kano, R.; Bando, T.; Ishikawa, R.; Giono, G.; Tsuneta, S.; Nakayama, S.; Tajima, T.
2015-10-01
We developed a polarization modulation unit (PMU) to rotate a waveplate continuously in order to observe solar magnetic fields by spectropolarimetry. The non-uniformity of the PMU rotation may cause errors in the measurement of the degree of linear polarization (scale error) and its angle (crosstalk between Stokes-Q and -U), although it does not cause an artificial linear polarization signal (spurious polarization). We rotated a waveplate with the PMU to obtain a polarization modulation curve and estimated the scale error and crosstalk caused by the rotation non-uniformity. The estimated scale error and crosstalk were {<} 0.01 % for both. This PMU will be used as a waveplate motor for the Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) rocket experiment. We confirm that the PMU performs and functions sufficiently well for CLASP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Nan
2008-03-01
China first adopted minimum energy performance standards (MEPS) in 1989. Today, there are standards for a wide range of domestic, commercial and selected industrial equipment. In 1999, China launched a voluntary endorsement label, which has grown to cover over 40 products including water-saving products (See Figure 1). Further, in 2005, China started a mandatory energy information label (also referred to as the 'Energy Label'). Today, the Energy Label is applied to four products including: air conditioners; household refrigerators; clothes washers; and unitary air conditioners (See Figure 2). MEPS and the voluntary endorsement labeling specifications have been updated and revised inmore » order to reflect technology improvements to those products in the market. These programs have had an important impact in reducing energy consumption of appliances in China. Indeed, China has built up a strong infrastructure to develop and implement product standards. Historically, however, the government's primary focus has been on the technical requirements for efficiency performance. Less attention has been paid to monitoring and enforcement with a minimal commitment of resources and little expansion of administrative capacity in this area. Thus, market compliance with both mandatory standards and labeling programs has been questionable and actual energy savings may have been undermined as a result. The establishment of a regularized monitoring system for tracking compliance with the mandatory standard and energy information label in China is a major area for program improvement. Over the years, the Collaborative Labeling and Appliance Standards Program (CLASP) has partnered with several Chinese institutions to promote energy-efficient products in China. CLASP, together with its implementing partner Lawrence Berkeley National Laboratory (LBNL), has assisted China in developing and updating the above-mentioned standards and labeling programs. Because of the increasing need for the development of a monitoring system to track compliance with standards and labeling, CLASP, with support from Japan's Ministry of Economy, Trade and Industry (METI), has expanded its ongoing collaboration with the China National Institute of Standards (CNIS) to include enforcement and monitoring. CNIS has already begun working on the issue of compliance. CNIS has conducted modest sample testing in 2006 for refrigerators, freezers and room air-conditioners, and repeated the same task in 2007 with a similar sample size for three products (refrigerators, freezers, air-conditioners and clothes washers). And, CNIS, with technical support from LBNL, has analyzed the data collected through testing. At the same time, parallel effort has also been paid to look at the potential impact of the label to 2020. In conjunction with CNIS, CLASP technical experts reviewed the standards development timeline of the four products currently subject to the mandatory energy information label. CLASP, with the support of METI/IEEJ, collaborated with CNIS to develop the efficiency grades, providing: technical input to the process; comment and advice on particular technical issues; as well as evaluation of the results. In addition, in order to effectively evaluate the impact of the label on China's market, CLASP further provided assistance to CNIS to collect data on both the efficiency distribution and product volume distribution of refrigerators on the market. This short report summarizes the status of Standards and Labeling program, current enforcement and monitoring mechanism in China, and states the importance of international collaborations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubo, M.; Katsukawa, Y.; Suematsu, Y.
High-cadence observations by the slit-jaw (SJ) optics system of the sounding rocket experiment known as the Chromospheric Lyman Alpha Spectropolarimeter (CLASP) reveal ubiquitous intensity disturbances that recurrently propagate in either the chromosphere or the transition region or both at a speed much higher than the speed of sound. The CLASP/SJ instrument provides a time series of two-dimensional images taken with broadband filters centered on the Ly α line at a 0.6 s cadence. The multiple fast-propagating intensity disturbances appear in the quiet Sun and in an active region, and they are clearly detected in at least 20 areas in amore » field of view of 527″ × 527″ during the 5 minute observing time. The apparent speeds of the intensity disturbances range from 150 to 350 km s{sup −1}, and they are comparable to the local Alfvén speed in the transition region. The intensity disturbances tend to propagate along bright elongated structures away from areas with strong photospheric magnetic fields. This suggests that the observed fast-propagating intensity disturbances are related to the magnetic canopy structures. The maximum distance traveled by the intensity disturbances is about 10″, and the widths are a few arcseconds, which are almost determined by a pixel size of 1.″03. The timescale of each intensity pulse is shorter than 30 s. One possible explanation for the fast-propagating intensity disturbances observed by CLASP is magnetohydrodynamic fast-mode waves.« less
Schuh, Cristian; Adiel Skupien, Jovito; Mesko, Mauro Elias; Valentini, Fernanda; Pereira-Cenci, Tatiana; Boscato, Noéli
2014-12-01
The present clinical report describes the prosthodontic management for a patient with uncontrolled bleeding and diabetes mellitus treated with a maxillary complete denture and a mandibular partial fixed dental prosthesis designed to interface with a removable cast framework partial denture retained by 2 ERA attachments. This approach was undertaken to improve both retention and stability of the distal extension Kennedy Class I removable partial denture. The rehabilitation provided better anterior esthetics than if treated with a conventional clasp retained removable partial denture, by employing a simple, practical design and offering a significant biomechanical advantages, restoring both oral health and function. Thus, this treatment modality, involving an ERA system and transfixation in fixed crowns, is an effective treatment and can be indicated as a clinical alternative for edentulous and partially edentulous patients with systemic disorders or for patients in economic situations that might preclude implant-based rehabilitation.
Nassani, M Z; Devlin, H; Tarakji, B; McCord, J F
2011-08-01
The aim of this survey was to investigate the quality of prescription for the fabrication of cobalt chromium removable partial dentures (RPDs) that are used to extend the shortened dental arches (SDAs). A survey of four commercial dental laboratories located in northern England was conducted. The target of this survey was cobalt chromium RPDs that were requested to restore SDAs comprising the anterior teeth and 2-4 premolars. Dentists' prescriptions were scrutinised, and a special data collection form was completed accordingly. A total of 94 dentists' prescriptions and associated SDA casts were examined. Almost all the requested cobalt chromium RPDs were clasp-retained RPDs (97%). Scrutinising the 91 prescriptions for clasp-retained cobalt chromium RPDs showed that dentists' prescriptions did not have any instructions about the design of the partial denture in a considerable proportion of the cases (32%). Teeth to be clasped were identified clearly in 45% of the prescriptions. A majority of the dentists (64%) failed to provide any instructions about the design of the rests to be placed on the most posterior premolar abutment teeth. A considerable proportion of the dentists delegated the task of selecting the type of the major connector to the dental technician (41%). Only 21 (23%) of the examined casts had clearly defined rest seat preparation. The outcome of this pilot survey shows inadequate quality of prescription in designing RPDs for patients with SDAs. This finding has an ethical and clinical bearing and does not fit with current legal guidelines relevant to designing RPDs. © 2010 Blackwell Publishing Ltd.
Comparison of Solar Fine Structure Observed Simultaneously in Lyα and Mg II h
NASA Astrophysics Data System (ADS)
Schmit, D.; Sukhorukov, A. V.; De Pontieu, B.; Leenaarts, J.; Bethge, C.; Winebarger, A.; Auchère, F.; Bando, T.; Ishikawa, R.; Kano, R.; Kobayashi, K.; Narukage, N.; Trujillo Bueno, J.
2017-10-01
The Chromospheric Lyman Alpha Spectropolarimeter (CLASP) observed the Sun in H I Lyα during a suborbital rocket flight on 2015 September 3. The Interface Region Imaging Telescope (IRIS) coordinated with the CLASP observations and recorded nearly simultaneous and co-spatial observations in the Mg II h and k lines. The Mg II h and Lyα lines are important transitions, energetically and diagnostically, in the chromosphere. The canonical solar atmosphere model predicts that these lines form in close proximity to each other and so we expect that the line profiles will exhibit similar variability. In this analysis, we present these coordinated observations and discuss how the two profiles compare over a region of quiet Sun at viewing angles that approach the limb. In addition to the observations, we synthesize both line profiles using a 3D radiation-MHD simulation. In the observations, we find that the peak width and the peak intensities are well correlated between the lines. For the simulation, we do not find the same relationship. We have attempted to mitigate the instrumental differences between IRIS and CLASP and to reproduce the instrumental factors in the synthetic profiles. The model indicates that formation heights of the lines differ in a somewhat regular fashion related to magnetic geometry. This variation explains to some degree the lack of correlation, observed and synthesized, between Mg II and Lyα. Our analysis will aid in the definition of future observatories that aim to link dynamics in the chromosphere and transition region.
Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease.
Galna, Brook; Barry, Gillian; Jackson, Dan; Mhiripiri, Dadirayi; Olivier, Patrick; Rochester, Lynn
2014-04-01
The Microsoft Kinect sensor (Kinect) is potentially a low-cost solution for clinical and home-based assessment of movement symptoms in people with Parkinson's disease (PD). The purpose of this study was to establish the accuracy of the Kinect in measuring clinically relevant movements in people with PD. Nine people with PD and 10 controls performed a series of movements which were measured concurrently with a Vicon three-dimensional motion analysis system (gold-standard) and the Kinect. The movements included quiet standing, multidirectional reaching and stepping and walking on the spot, and the following items from the Unified Parkinson's Disease Rating Scale: hand clasping, finger tapping, foot, leg agility, chair rising and hand pronation. Outcomes included mean timing and range of motion across movement repetitions. The Kinect measured timing of movement repetitions very accurately (low bias, 95% limits of agreement <10% of the group mean, ICCs >0.9 and Pearson's r>0.9). However, the Kinect had varied success measuring spatial characteristics, ranging from excellent for gross movements such as sit-to-stand (ICC=.989) to very poor for fine movement such as hand clasping (ICC=.012). Despite this, results from the Kinect related strongly to those obtained with the Vicon system (Pearson's r>0.8) for most movements. The Kinect can accurately measure timing and gross spatial characteristics of clinically relevant movements but not with the same spatial accuracy for smaller movements, such as hand clasping. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Comparison of Solar Fine Structure Observed Simultaneously in Ly α and Mg ii h
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmit, D.; Sukhorukov, A. V.; Leenaarts, J.
The Chromospheric Lyman Alpha Spectropolarimeter (CLASP) observed the Sun in H i Ly α during a suborbital rocket flight on 2015 September 3. The Interface Region Imaging Telescope ( IRIS ) coordinated with the CLASP observations and recorded nearly simultaneous and co-spatial observations in the Mg ii h and k lines. The Mg ii h and Ly α lines are important transitions, energetically and diagnostically, in the chromosphere. The canonical solar atmosphere model predicts that these lines form in close proximity to each other and so we expect that the line profiles will exhibit similar variability. In this analysis, wemore » present these coordinated observations and discuss how the two profiles compare over a region of quiet Sun at viewing angles that approach the limb. In addition to the observations, we synthesize both line profiles using a 3D radiation-MHD simulation. In the observations, we find that the peak width and the peak intensities are well correlated between the lines. For the simulation, we do not find the same relationship. We have attempted to mitigate the instrumental differences between IRIS and CLASP and to reproduce the instrumental factors in the synthetic profiles. The model indicates that formation heights of the lines differ in a somewhat regular fashion related to magnetic geometry. This variation explains to some degree the lack of correlation, observed and synthesized, between Mg ii and Ly α . Our analysis will aid in the definition of future observatories that aim to link dynamics in the chromosphere and transition region.« less
Politis, Christopher E; Mowat, David L; Keen, Deb
2017-06-16
The Canadian Partnership Against Cancer funded 12 large-scale knowledge to action cancer and chronic disease prevention projects between 2009 and 2016 through the Coalitions Linking Action and Science for Prevention (CLASP) initiative. Two projects, Healthy Canada by Design (HCBD) and Children's Mobility, Health and Happiness (CMHH), developed policies to address physical activity and the built environment through a multisectoral approach. A qualitative analysis involving a review of 183 knowledge products and 8 key informant interviews was conducted to understand what policy changes occurred, and the underlying critical success factors, through these projects. Both projects worked at the local level to change physical activity and built environment policy in 203 sites, including municipalities and schools. Both projects brought multisectoral expertise (e.g., public health, land use planning, transportation engineering, education, etc.) together to inform the development of local healthy public policy in the areas of land use, transportation and school travel planning. Through the qualitative analysis of the knowledge products and key informant interviews, 163 policies were attributed to HCBD and CMHH work. Fourteen "pathways to policy" were identified as critical success factors facilitating and accelerating the development and implementation of physical activity and built environment policy. Of the 14 pathways to policy, 8 had a focus on multisectoral collaboration. The lessons learned from the CLASP experience could support enhanced multisectoral collaborations to accelerate the development and implementation of physical activity and built environment policy in new jurisdictions across Canada and internationally.
CLASP/SJ Observations of Rapid Time Variations in the Ly α Emission in a Solar Active Region
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ishikawa, Shin-nosuke; Kubo, Masahito; Katsukawa, Yukio
The Chromospheric Ly α SpectroPolarimeter (CLASP) is a sounding rocket experiment launched on 2015 September 3 to investigate the solar chromosphere and transition region. The slit-jaw (SJ) optical system captured Ly α images with a high time cadence of 0.6 s. From the CLASP/SJ observations, many variations in the solar chromosphere and transition region emission with a timescale of <1 minute were discovered. In this paper, we focus on the active region within the SJ field of view and investigate the relationship between short (<30 s) temporal variations in the Ly α emission and the coronal structures observed by Solarmore » Dynamics Observatory/Atmospheric Imaging Assembly (AIA). We compare the Ly α temporal variations at the coronal loop footpoints observed in the AIA 211 Å (≈2 MK) and AIA 171 Å (≈0.6 MK) channels with those in the regions with bright Ly α features without a clear association with the coronal loop footpoints. We find more short (<30 s) temporal variations in the Ly α intensity in the footpoint regions. Those variations did not depend on the temperature of the coronal loops. Therefore, the temporal variations in the Ly α intensity at this timescale range could be related to the heating of the coronal structures up to temperatures around the sensitivity peak of 171 Å. No signature was found to support the scenario that these Ly α intensity variations were related to the nanoflares. Waves or jets from the lower layers (lower chromosphere or photosphere) are possible causes for this phenomenon.« less
Souza, Jose Everaldo de Aquino; Silva, Nelson Renato Franca Alves da; Coelho, Paulo Guilherme; Zavanelli, Adriana Cristina; Ferracioli, Renata Cristina Silveira Rodrigues; Zavanelli, Ricardo Alexandre
2011-05-01
There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and considering different period of time (0, 1/2, 1, 2, 3, 4 and 5 years). Using two metallic matrices, representing a partially edentulous mandibular right hemiarch with the first molar crown, canine root and without premolars, 60 frameworks were fabricated. Three groups (n = 20) of each metal were cast and each group was divided into two subgroups (n = 10), corresponding the molar undercut of 0.25 mm and 0.75 mm. The nylon male was positioned at the matrix and attached to the acrylic resin of the prosthetic base. The samples were subjected to an insertion and removal test under artificial saliva environment. The data were analyzed and compared with ANOVAs and Tukey's test at 95% of probability. The groups cast in cobaltchromium and nickel-chromium-titanium had the highest mean retention strength (5.58 N and 6.36 N respectively) without significant difference between them, but statistically different from the group cast in commercially pure titanium, which had the lowest mean retention strength in all the periods (3.46 N). The association frameworks using nickel-chromium- titanium and cobalt-chromium could be used with 0.25 mm and 0.75 mm of undercut, but the titanium samples seems to decrease the retention strength, mainly in the 0.75 mm undercut. The circumferential clasps cast in commercially pure titanium used in 0.75 mm undercuts have a potential risk of fractures, especially after the 2nd year of use. This in vitro study showed that the framework association between cast clasp and an extra resilient attachment are suitable to the three metals evaluated, but strongly suggest extra care with commercially pure titanium in undercut of 0.75 mm. Frameworks fabricated in Cp Ti tend to decrease in retentive strength over time and have a potential risk of fracture in less than 0.75 mm of undercut.
Fueki, K; Yoshida-Kohno, E; Wakabayashi, N
2017-05-01
We investigated the efficacy of non-metal clasp dentures (NMCDs) with regard to the oral health-related quality of life (OHRQoL) and compare the findings with those for conventional metal clasp-retained dentures (MCDs). This single-centre, randomised controlled, two-phase, open label, cross-over trial included 28 partially dentate individuals. The patients were randomised to receive MCDs followed by NMCDs, or the opposite sequence (n = 14 in each group); each denture was worn for 3 months. OHRQoL was evaluated using the Oral Health Impact Profile-Japanese version (OHIP-J) at entry (T-entry; before treatment with the first denture) and at 3 months after treatment with each denture (T3). An examiner evaluated denture stability, oral appearance and surface roughness before denture delivery (T0) and at T3 and denture hygiene at T3. A total of 24 patients completed the trial. There were no complications related to the dentures, abutment teeth or denture-bearing mucosa during the follow-up periods for both dentures. The mean OHIP summary score was lower for NMCDs than for MCDs, and the difference (9 points) was greater than the minimal important difference (6 points), indicating the difference was clinically relevant. The effect size was medium (0·70). Statistical analyses with linear mixed models found a significant effect of the denture type on the OHIP summary score and scores for the Oro-facial appearance, Oro-facial pain and Psychological impact domains (NMCD < MCD; P < 0·05). The results of our study suggest that NMCDs allow for better OHRQoL compared with MCDs. © 2017 John Wiley & Sons Ltd.
Expression of serotonin receptors in human lower esophageal sphincter
LI, HE-FEI; LIU, JUN-FENG; ZHANG, KE; FENG, YONG
2015-01-01
Serotonin (5-HT) is a neurotransmitter and vasoactive amine that is involved in the regulation of a large number of physiological functions. The wide variety of 5-HT-mediated functions is due to the existence of different classes of serotonergic receptors in the mammalian gastrointestinal tract and nervous system. The aim of this study was to explore the expression of multiple types of 5-HT receptor (5-HT1AR, 5-HT2AR, 5-HT3AR, 5-HT4R, 5-HT5AR, 5-HT6R and 5-HT7R) in sling and clasp fibers from the human lower esophageal sphincter (LES). Muscle strips of sling and clasp fibers from the LES were obtained from patients undergoing esophagogastrectomy, and circular muscle strips from the esophagus and stomach were used as controls. Reverse transcription-polymerase chain reaction (RT-PCR), quantitative PCR and western blotting were used to investigate the expression of the various 5-HT receptor types. Messenger RNA for all seven 5-HT receptor types was identified in the sling and clasp fibers of the LES. At the mRNA level, the expression levels were highest for 5-HT3AR and 5-HT4R, and lowest for 5-HT5AR, 5-HT6R and 5-HT7R. At the protein level, the expression levels were highest for 5-HT3AR and 5-HT4R, followed by 5-HT1AR and 5-HT2AR; 5-HT7R was also detected at a low level. The expression of 5-HT5AR and 5-HT6R proteins was not confirmed. The results indicate that a variety of 5-HT receptor types can be detected in the human LES and probably contribute to LES function. PMID:25452775
Isolation of the mite Myocoptes musculinus Koch from the Spinifex Hopping mouse (Notomys alexis).
Old, J M; Hill, N J; Deane, E M
2007-04-01
This paper reports on the isolation and identification of the fur-clasping mite, Myocoptes musculinus, from the faeces of the Spinifex Hopping mouse (Notomys alexis). This investigation adds to the sparse records of ectoparasites collected from native Australian murids.
A novel system for organ and tissues preservation: the refrigerating hyperbaric chamber.
Guimarães, F A G; Taha, M O; Simões, M J; Moino, C A A; Santos, I V; Amador, J C; Santos, R A; Queiroz, R B; Amaro, R R; Jesus, M A S
2006-01-01
This study was designed to investigate the feasibility of building a simple and inexpensive device to preserve organs or tissues in hyperbaric and hypothermic conditions. The device was built on a 40-cm wide, 28-cm long, and 23-cm deep stainless steel chassis. The pressure vessel was built by a 7.8-cm bore stainless steel cylinder put inside another 12-cm cylinder welded together and closed by a steel plate on the top and bottom. The inferior plate was welded, and the superior one was fixed by manual clasp nut. The cooling system is made up of air compressor, condenser, expansion area, and cooling worm that is located between the cylinders. The temperature-controlling device is a computer processor contained in an integrated-circuit chip, with a on-off system to maintain the chamber temperature between 2 degrees to 4 degrees C. The compression of the chamber is performed by lateral coupling with the oxygen cylinder and is maintained at 5.5 absolute atmospheres and controlled by air pressure gauge. The maximal work pressure was evaluated by spreadsheet. Temperature or pressure changes were evaluated by 12- and 24-hour assays. The maximal work pressure permitted was 6.5 absolute atmospheres. Thus, the container was free from danger. The temperature inside the chamber was kept between 2 degrees and 4 degrees C. The production costs of the prototype was US$1000. The manufacture of the refrigerating hyperbaric chamber is viable, simple, and inexpensive.
Ubiquitous Fast Propagating Intensity Disturbances in Solar Chromosphere
NASA Technical Reports Server (NTRS)
Kubo, M.; Katsukawa, Y.; Suematsu, Y.; Kano, R.; Bando, T.; Narukage, N.; Ishikawa, R.; Hara, H.; Giono, G.; Winebarger, A.;
2016-01-01
High cadence observations by the slit-jaw (SJ) optics system of the sounding rocket experiment "the Chromospheric Lyman Alpha SpectroPolarimeter (CLASP)" reveal ubiquitous intensity disturbances that recurrently propagate in either the chromosphere, transition region, or both at a speed much higher than the sound speed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Jiang
2007-03-01
China has developed a comprehensive program of energy efficiency standards and labels for household appliances. In 1989, China first launched its minimum energy performance standards (MEPS), which are now applied to an extensive list of products. In 1998, China launched a voluntary energy endorsement label, which has grown to cover both energy-saving and water-saving products. And, in 2005, China launched a mandatory energy information label that initially covered two products. CLASP has assisted China in developing 11 minimum energy performance standards (MEPS) for 9 products and endorsement labels for 11 products including: refrigerators; air conditioners; televisions; printers; computers; monitors; faxmore » machines; copiers; DVD/VCD players; external power supplies; and set-top boxes. CLASP has also assisted China in the development of the mandatory energy information label. Increasingly, attention is being placed on maximum energy savings from China's standards and labeling (S&L) efforts in order to meet the recently announced goal of reducing China's energy intensity by 20 percent by 2010 with an interim objective of 4 percent in 2006. China's mandatory standards system is heavily focused on the technical requirements for efficiency performance, but historically, it has lacked administrative and personnel capacity to undertake monitoring and enforcement of these legally binding standards. Similarly, resources for monitoring and enforcement have been quite limited. As a consequence, compliance to both the mandatory standards and the mandatory energy information label is uneven with the potential and likely result of lost energy savings. Thus, a major area for improvement, which could significantly increase overall energy savings, is the creation and implementation of a regularized monitoring system for tracking the compliance to, and enforcement of, mandatory standards and the energy information label in China. CLASP has been working with the China National Institute of Standardization (CNIS), the China Administration for Quality, Supervision, Inspection and Quarantine (AQSIQ) and relevant stakeholders in the industry to develop a stronger system of monitoring and enforcement. In November 2005, CNIS and LBNL (a CLASP implementing partner) with funding from the Energy Foundation jointly organized an international workshop to present the international best practices in S&L monitoring and enforcement. Currently, CNIS is developing a guideline for monitoring and enforcement for appliance standards. With support from METI, CLASP has been able to expand the on-going collaboration with CNIS to include enforcement needs for the mandatory energy information label and to accelerate the progress of the project to develop a more robust monitoring and enforcement for S&L programs in China. This expanded effort has included: (1) Holding an enforcement and monitoring roadmap planning workshop with key S&L stakeholders; (2) Interviews with S&L stakeholders on the need and scope of national compliance tests; (3) Research on past enforcement activities; (4) An analysis of compliance data from the mandatory energy information labeling program; (5) Interviews with stakeholders on the need and scope of testing infrastructure; and (6) Development of a roadmap for future activities. This report summarizes the findings of these activities and identifies the progress that China is making, and can make, toward developing a stronger system of monitoring and enforcement (M&E). In sum, it outlines a vision of moving forward with more vigorous M&E in China.« less
The Consortium for Higher Education Tax Reform Report
ERIC Educational Resources Information Center
Center for Postsecondary and Economic Success, 2014
2014-01-01
This White Paper presents the work of the Consortium for Higher Education Tax Reform, a partnership funded by the Bill & Melinda Gates Foundation as part of the second phase of its Reimagining Aid Design and Delivery (RADD) initiative. Consortium partners are the Center for Postsecondary and Economic Success at CLASP, the Education Trust, New…
Ferretti, Nelson E; Pérez-Miles, Fernando
2011-09-01
Intraspecific interactions of araneomorph spiders have received considerable attention, but there are few detailed studies on intraspecific interactions of mygalomorph spiders. Moreover, a thorough understanding of theraphosid biology and ecology is necessary from a conservation standpoint because natural populations may be threatened by habitat disturbances and captures for pet commerce. We described the behavior of conspecific individuals of Grammostola schulzei during non-sexual interactions, under laboratory conditions. Pairs of individuals involving adult males, adult females and juveniles were confronted and observed in resident and intruder conditions, totalizing 115 trials. When confronted two adult females, they retreated or grappled, and performed gaping display with bite attempts, usually resulted in severe injury of the intruder spiders. When confronted females with large juveniles, we frequently observed cannibalism on juveniles. Juveniles exposed to females or to other juveniles retreated or made leg tapping with forelegs and palpal drumming, which are common displays of courting adult males. Adult males courted and clasped some juveniles, but juveniles avoided or reject clasping. The behaviors observed during intraspecific interactions could play an important role determining spatial distribution and could lead to behavioral adaptations of territoriality.
Comparative study of two commercially pure titanium casting methods
RODRIGUES, Renata Cristina Silveira; FARIA, Adriana Claudia Lapria; ORSI, Iara Augusta; de MATTOS, Maria da Gloria Chiarello; MACEDO, Ana Paula; RIBEIRO, Ricardo Faria
2010-01-01
The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. Objective This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. Material and Methods 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). Results Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. Conclusion Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values. PMID:21085805
Chakraborty, Sandeep
2014-01-01
The ability to accurately and effectively predict the interaction between proteins and small drug-like compounds has long intrigued researchers for pedagogic, humanitarian and economic reasons. Protein docking methods (AutoDock, GOLD, DOCK, FlexX and Glide to name a few) rank a large number of possible conformations of protein-ligand complexes using fast algorithms. Previously, it has been shown that structural congruence leading to the same enzymatic function necessitates the congruence of electrostatic properties (CLASP). The current work presents a methodology for docking a ligand into a target protein, provided that there is at least one known holoenzyme with ligand bound - DOCLASP (Docking using CLASP). The contact points of the ligand in the holoenzyme defines a motif, which is used to query the target enzyme using CLASP. If there are significant matches, the holoenzyme and the target protein are superimposed based on congruent atoms. The same linear and rotational transformations are also applied to the ligand, thus creating a unified coordinate framework having the holoenzyme, the ligand and the target enzyme. In the current work, the dipeptidyl peptidase-IV inhibitor vildagliptin was docked to the PI-PLC structure complexed with myo-inositol using DOCLASP. Also, corroboration of the docking of phenylthiourea to the modelled structure of polyphenol oxidase (JrPPO1) from walnut is provided based on the subsequently solved structure of JrPPO1 (PDBid:5CE9). Analysis of the binding of the antitrypanosomial drug suramin to nine non-homologous proteins in the PDB database shows a diverse set of binding motifs, and multiple binding sites in the phospholipase A2-likeproteins from the Bothrops genus of pitvipers. The conformational changes in the suramin molecule on binding highlights the challenges in docking flexible ligands into an already 'plastic' binding site. Thus, DOCLASP presents a method for 'soft docking' ligands to proteins with low computational requirements.
Development of Flight Slit-Jaw Optics for Chromospheric Lyman-Alpha SpectroPolarimeter
NASA Technical Reports Server (NTRS)
Kubo, Masahito; Suematsu, Yoshinori; Kano, Ryohei; Bando, Takamasa; Hara, Hirohisa; Narukage, Noriyuki; Katsukawa, Yukio; Ishikawa, Ryoko; Ishikawa, Shin-nosuke; Kobiki, Toshihiko;
2015-01-01
In sounding rocket experiment CLASP, I have placed a slit a mirror-finished around the focal point of the telescope. The light reflected by the mirror surface surrounding the slit is then imaged in Slit-jaw optical system, to obtain the alpha-ray Lyman secondary image. This image, not only to use the real-time image in rocket flight rocket oriented direction selection, and also used as a scientific data showing the spatial structure of the Lyman alpha emission line intensity distribution and solar chromosphere around the observation area of the polarimetric spectroscope. Slit-jaw optical system is a two off-axis mirror unit part including a parabolic mirror and folding mirror, Lyman alpha transmission filter, the optical system magnification 1x consisting camera. The camera is supplied from the United States, and the other was carried out fabrication and testing in all the Japanese side. Slit-jaw optical system, it is difficult to access the structure, it is necessary to install the low place clearance. Therefore, influence the optical performance, the fine adjustment is necessary optical elements are collectively in the form of the mirror unit. On the other hand, due to the alignment of the solar sensor in the US launch site, must be removed once the Lyman alpha transmission filter holder including a filter has a different part from the mirror unit. In order to make the structure simple, stray light measures Aru to concentrate around Lyman alpha transmission filter. To overcome the difficulties of performing optical alignment in Lyman alpha wavelength absorbed by the atmosphere, it was planned following four steps in order to reduce standing time alignment me. 1: is measured in advance refractive index at Lyman alpha wavelength of Lyman alpha transmission filter (121.567nm), to prepare a visible light Firuwo having the same optical path length in the visible light (630nm). 2: The mirror structure CLASP before mounting unit standing, dummy slit and camera standing prescribed position in leading frame is, to complete the internal alignment adjustment. 3: CLASP structure F mirror unit and by attaching the visible light filter, as will plague the focus is carried out in standing position adjustment visible flight products camera. 4: Replace the Lyman alpha transmission filter, it is confirmed by Lyman alpha wavelength (under vacuum) the requested optical performance have come. Currently, up to 3 of the steps completed, it was confirmed in the visible light optical performance that satisfies the required value sufficiently extended. Also, put in Slit-jaw optical system the sunlight through the telescope of CLASP, it is also confirmed that and that stray light rejection no vignetting is in the field of view meets request standing.
Development of Flight Slit-Jaw Optics for Chromospheric Lyman-Alpha SpectroPolarimeter
NASA Technical Reports Server (NTRS)
Kubo, Masahito; Suematsu, Yoshinori; Kano, Ryohei; Bando, Takamasa; Hara, Hirohisa; Narukage, Noriyuki; Katsukawa, Yukio; Ishikawa, Ryoko; Ishikawa, Shin-nosuke; Kobiki, Toshihiko;
2015-01-01
In sounding rocket experiment CLASP, I have placed a slit a mirror-finished around the focal point of the telescope. The light reflected by the mirror surface surrounding the slit is then imaged in Slit-jaw optical system, to obtain the a-ray Lyman secondary image. This image, not only to use the real-time image in rocket flight rocket oriented direction selection, and also used as a scientific data showing the spatial structure of the Lyman alpha emission line intensity distribution and solar chromosphere around the observation area of the polarimetric spectroscope. Slit-jaw optical system is a two off-axis mirror unit part including a parabolic mirror and folding mirror, Lyman alpha transmission filter, the optical system magnification 1x consisting camera. The camera is supplied from the United States, and the other was carried out fabrication and testing in all the Japanese side. Slit-jaw optical system, it is difficult to access the structure, it is necessary to install the low place clearance. Therefore, influence the optical performance, the fine adjustment is necessary optical elements are collectively in the form of the mirror unit. On the other hand, due to the alignment of the solar sensor in the US launch site, must be removed once the Lyman alpha transmission filter holder including a filter has a different part from the mirror unit. In order to make the structure simple, stray light measures Aru to concentrate around Lyman alpha transmission filter. To overcome the difficulties of performing optical alignment in Lyman alpha wavelength absorbed by the atmosphere, it was planned 'following four steps in order to reduce standing time alignment me. 1. is measured in advance refractive index at Lyman alpha wavelength of Lyman alpha transmission filter (121.567nm), to prepare a visible light Firuwo having the same optical path length in the visible light (630nm).2. The mirror structure CLASP before mounting unit standing, dummy slit and camera standing prescribed position in leading frame is, to complete the internal alignment adjustment. 3. CLASP structure F mirror unit and by attaching the visible light filter, as will plague the focus is carried out in standing position adjustment visible flight products camera. 4. Replace the Lyman alpha transmission filter, it is confirmed by Lyman alpha wavelength (under vacuum) the requested optical performance have come. Currently, up to 3 of the steps completed, it was confirmed in the visible light optical performance that satisfies the required value sufficiently extended. Also, put in Slit-jaw optical system the sunlight through the telescope of CLASP, it is also confirmed that and that stray light rejection no vignetting is in the field of view meets request standing.
Automated Scheduling of Science Activities for Titan Encounters by Cassini
NASA Technical Reports Server (NTRS)
Ray, Trina L.; Knight, Russel L.; Mohr, Dave
2014-01-01
In an effort to demonstrate the efficacy of automated planning and scheduling techniques for large missions, we have adapted ASPEN (Activity Scheduling and Planning Environment) [1] and CLASP (Compressed Large-scale Activity Scheduling and Planning) [2] to the domain of scheduling high-level science goals into conflict-free operations plans for Titan encounters by the Cassini spacecraft.
Assessing Student Peer Dialogue in Collaborative Settings: A Window into Student Reasoning
ERIC Educational Resources Information Center
Stone, Antoinette
2013-01-01
The use of science classroom discourse analysis as a way to gain a better understanding of various student cognitive outcomes has a rich history in Science Education in general and Physics Education Research (PER) in particular. When students talk to each other in a collaborative peer instruction environment, such as in the CLASP classes…
Ratio Tables to Promote Proportional Reasonings in the Primary Classroom
ERIC Educational Resources Information Center
Dole, Shelley
2008-01-01
There are many classroom activities that can be implemented with primary students that introduce and immerse them in ratio investigations. Some enjoyable tasks include finding the ratio of tongue rollers to non-tongue rollers in the classroom; left-hand dominant to right-hand dominant; right-thumb over left-thumb when clasping the hands to…
ERIC Educational Resources Information Center
Crellin, Matt; Kelly, Patrick; Prince, Heath
2012-01-01
General acceptance of the strong relationships between education, income, and public economic strength is at the core of all of college attainment goals at the national and state levels. The National Center for Higher Education Management Systems (NCHEMS) and the Center for Law and Social Policy (CLASP) have collaborated to develop online tools…
Building Comprehensive State Systems for Vulnerable Babies: A Resource for State Leaders
ERIC Educational Resources Information Center
Center for Law and Social Policy, Inc. (CLASP), 2011
2011-01-01
Center for Law and Social Policy (CLASP) has developed this resource to help state leaders strategize how to create or improve early childhood systems to meet the needs of vulnerable babies and toddlers, their families, and pregnant women. Every state has the pieces of a comprehensive early childhood system in place. This tool will help state…
Questions to Consider When Reviewing Draft WIOA State Plans. WIOA Game Plan for Low-Income People
ERIC Educational Resources Information Center
Center for Law and Social Policy, Inc. (CLASP), 2016
2016-01-01
As states release draft Workforce Innovation and Opportunity Act (WIOA) state plans for public comment, advocates and other stakeholders have an important opportunity to improve them. The Center for Law and Social Policy (CLASP) is offering a list of questions, which is included in this document, to consider when reviewing state plans. These…
Approximate reasoning using terminological models
NASA Technical Reports Server (NTRS)
Yen, John; Vaidya, Nitin
1992-01-01
Term Subsumption Systems (TSS) form a knowledge-representation scheme in AI that can express the defining characteristics of concepts through a formal language that has a well-defined semantics and incorporates a reasoning mechanism that can deduce whether one concept subsumes another. However, TSS's have very limited ability to deal with the issue of uncertainty in knowledge bases. The objective of this research is to address issues in combining approximate reasoning with term subsumption systems. To do this, we have extended an existing AI architecture (CLASP) that is built on the top of a term subsumption system (LOOM). First, the assertional component of LOOM has been extended for asserting and representing uncertain propositions. Second, we have extended the pattern matcher of CLASP for plausible rule-based inferences. Third, an approximate reasoning model has been added to facilitate various kinds of approximate reasoning. And finally, the issue of inconsistency in truth values due to inheritance is addressed using justification of those values. This architecture enhances the reasoning capabilities of expert systems by providing support for reasoning under uncertainty using knowledge captured in TSS. Also, as definitional knowledge is explicit and separate from heuristic knowledge for plausible inferences, the maintainability of expert systems could be improved.
Cilip, Christopher M; Kerr, Duane; Latimer, Cassandra A; Rosenbury, Sarah B; Giglio, Nicholas C; Hutchens, Thomas C; Nau, William H; Fried, Nathaniel M
2017-04-01
Infrared (IR) lasers are being explored as an alternative to radiofrequency (RF) and ultrasonic (US) devices for rapid hemostasis with minimal collateral zones of thermal damage and tissue necrosis. Previously, a 1,470 nm IR laser sealed and cut ex vivo porcine renal arteries of 1-8 mm diameter in 2 seconds, yielding burst pressures greater than 1,200 mmHg and thermal coagulation zones less than 3 mm. This preliminary study describes in vivo testing of a handheld laser probe in a porcine model. A handheld prototype with vessel/tissue clasping mechanism was tested on 73 blood vessels less than 6 mm diameter using 1,470 nm laser power of 35 W for 1-5 seconds. Device power settings, irradiation time, tissue type, vessel diameter, and histology sample number were recorded for each procedure. The probe was evaluated for hemostasis after sealing isolated and bundled arteriole/venous (A/V) vasculature of porcine abdomen and hind leg. Sealed vessel samples were collected for histological analysis of lateral thermal damage. Hemostasis was achieved in 57 of 73 seals (78%). The probe consistently sealed vasculature in small bowel mesentery, mesometrium, and gastrosplenic and epiploic regions. Seal performance was less consistent on hind leg vasculature including saphenous arteries/bundles and femoral and iliac arteries. Collagen denaturation averaged 1.6 ± 0.9 mm in eight samples excised for histologic examination. A handheld laser probe sealed porcine vessels, in vivo. Further probe development and laser parameter optimization is necessary before infrared lasers may be evaluated as an alternative to RF and US vessel sealing devices. Lasers Surg. Med. 49:366-371, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Schumacher, Rachel; Hamm, Katie; Ewen, Danielle
2007-01-01
A growing number of state leaders believe that it is essential to expand high-quality early learning and development opportunities for all young children before they reach kindergarten. A key component of this strategy is providing access to voluntary, high-quality pre-kindergarten programs, especially for low-income children. Over the last few…
ERIC Educational Resources Information Center
Reimherr, Patrick; Harmon, Tim; Strawn, Julie; Choitz, Vickie
2013-01-01
Any reform of federal student aid must address the twin challenges of college affordability and completion, which are inextricably linked. Here, CLASP has proposed ways to redirect existing federal student aid spending toward the low- and modest income families who need it most. These are the students for whom federal aid makes a difference in…
ERIC Educational Resources Information Center
Hamm, Katie
2006-01-01
This is the eighth brief in a series of Center for Law and Social Policy (CLASP) analyses of Head Start Program Information Report data. All Head Start programs are required to complete the Program Information Report (PIR) on an annual basis. Based on information reported through the PIR, this policy brief describes the characteristics of Head…
ERIC Educational Resources Information Center
Ewen, Danielle; Matthews, Hannah
2007-01-01
This paper explores the range of ways in which school districts are using Title I funds for early education through kindergarten and examines how the implementation of No Child Left Behind (NCLB) has impacted those investments. It also makes recommendations for local education agencies (LEAs) interested in creating Title I-funded early education…
Plant Guide: Bluebunch wheatgrass: Pseudoroegneria spicata
Daniel G. Ogle; Loren St. John; Thomas A. Jones
2010-01-01
Grass Family (Poaceae). Bluebunch wheatgrass is a perennial native bunchgrass. Bluebunch wheatgrass is highly variable and grows to 1.5 to 4 feet (0.4 to 1.2 m) tall with seed spikes 3 to 8 inches (76 to 200 mm) long. The auricles are pointed and semi-clasping to nearly lacking. Leaves are lax, cauline, flat to in-rolled, 0.6 to 0.25 inches (4 to 6 mm) wide, and green...
Li, Y; Zheng, G; Lin, H
2014-12-18
To develop a new kind of dental radiographic image quality indicator (IQI) for internal quality of casting metallic restoration to influence on its usage life. Radiographic image quality indicator method was used to evaluate the depth of the defects region and internal quality of 127 casting metallic restoration and the accuracy was compared with that of conventional callipers method. In the 127 cases of casting metallic restoration, 9 were found the thickness less than 0.7 mm and the thinnest thickness only 0.2 mm in 26 casting metallic crowns or bridges' occlusal defects region. The data measured by image quality indicator were consistent with those measured by conventional gauging. Two metal inner crowns were found the thickness less than 0.3 mm in 56 porcelain crowns or bridges. The thickness of casting removable partial denture was more than 1.0 mm, but thinner regions were not found. It was found that in a titanium partial denture, the X-ray image of clasp was not uniform and there were internal porosity defects in the clasp. Special dental image quality indicator can solve the visual error problems caused by different observing backgrounds and estimate the depth of the defects region in the casting.
Aluminum Manganese Molten Salt Plating
2006-06-01
fixture from overhead crane hook and locate fixture over the closed acid tank. 2. Ventilation a. Set valve positions as follows (same as Section I.4.a...overhead crane hook and position the fixture over the closed acid tank. (Will need to remove the top stainless steel rod, clasp the remaining rod with the... crane hook , replace the rod that was removed by threading it through the crane hook , and finally lift the fixture off its storage hook . The cotter
NASA Technical Reports Server (NTRS)
James, T. A.; Hall, B. C.; Newbold, P. M.
1972-01-01
A comparative evaluation was made of eight higher order languages of general interest in the aerospace field: PL/1; HAL; JOVIAL/J3; SPL/J6; CLASP; ALGOL 60; FORTRAN 4; and MAC360. A summary of the functional requirements for a language for general use in manned aerodynamic applications is presented. The evaluation supplies background material to be used in assessing the worth of each language for some particular application.
Manipulator for rotating and translating a sample holder
van de Water, Jeroen [Breugel, NL; van den Oetelaar, Johannes [Eindhoven, NL; Wagner, Raymond [Gorinchem, NL; Slingerland, Hendrik Nicolaas [Venlo, NL; Bruggers, Jan Willem [Eindhoven, NL; Ottevanger, Adriaan Huibert Dirk [Malden, NL; Schmid, Andreas [Berkeley, CA; Olson, Eric A [Champaign, IL; Petrov, Ivan G [Champaign, IL; Donchev, Todor I [Urbana, IL; Duden, Thomas [Kensington, CA
2011-02-08
A manipulator for use in e.g. a Transmission Electron Microscope (TEM) is described, said manipulator capable of rotating and translating a sample holder (4). The manipulator clasps the round sample holder between two members (3A, 3B), said members mounted on actuators (2A, 2B). Moving the actuators in the same direction results in a translation of the sample holder, while moving the actuators in opposite directions results in a rotation of the sample holder.
A secondary copulatory structure in a female insect: a clasp for a nuptial meal?
NASA Astrophysics Data System (ADS)
Gwynne, Darryl T.
2002-03-01
Secondary copulatory structures are well-known in male dragonflies and spiders. Here I report a secondary copulatory organ in female ground weta, Hemiandrus pallitarsis (Ensifera, Orthoptera - crickets and allies). The organ, located on the underside of the abdomen, appears to secure the male's genitalia during the transfer of a spermatophylax nuptial meal to this location, an area quite separate from the female's primary copulatory structures, where the sperm ampulla is attached.
2012-11-30
At the Gagarin Cosmonaut Training Center in Star City, Russia, the Expedition 34/35 prime crew clasps hands at the conclusion of a news conference Nov. 29, 2012 as they complete preparations for launch Dec. 19 to the International Space Station in their Soyuz TMA-07M spacecraft from the Baikonur Cosmodrome in Kazakhstan. From left to right are NASA Flight Engineer Tom Marshburn, Soyuz Commander Roman Romanenko and Flight Engineer Chris Hadfield of the Canadian Space Agency. NASA/Stephanie Stoll
Full 3-dimensional digital workflow for multicomponent dental appliances: A proof of concept.
van der Meer, W Joerd; Vissink, Arjan; Ren, Yijin
2016-04-01
The authors used a 3-dimensional (3D) printer and a bending robot to produce a multicomponent dental appliance to assess whether 3D digital models of the dentition are applicable for a full digital workflow. The authors scanned a volunteer's dentition with an intraoral scanner (Lava Chairside Oral Scanner C.O.S., 3M). A digital impression was used to design 2 multicomponent orthodontic appliances. Biocompatible acrylic baseplates were produced with the aid of a 3D printer. The metal springs and clasps were produced by a bending robot. The fit of the 2 appliances was assessed by 2 experienced orthodontists. The authors assessed both orthodontic appliances with the volunteer's dentition and found the fit to be excellent. Clinicians can fully produce a multicomponent dental appliance consisting of both an acrylic baseplate and other parts, such as clasps, springs, or screws, using a digital workflow process without the need for a physical model of the patient's dentition. Plaster models can be superfluous for orthodontic treatment as digital models can be used in all phases of a full digital workflow in orthodontics. The arduous task of making a multicomponent dental appliance that involves bending wires can possibly be replaced by a computer, design software, a 3D printer, and a bending robot. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Giono, G.; Katsukawa, Y.; Ishikawa, R.; Narukage, N.; Kano, R.; Kubo, M.; Ishikawa, S.; Bando, T.; Hara, H.; Suematsu, Y.; Winebarger, A.; Kobayashi, K.; Auchère, F.; Trujillo Bueno, J.
2016-07-01
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument developed at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. The instrument main scientific goal is to achieve polarization measurement of the Lyman-α line at 121.56 nm emitted from the solar upper-chromosphere and transition region with an unprecedented 0.1% accuracy. The optics are composed of a Cassegrain telescope coated with a "cold mirror" coating optimized for UV reflection and a dual-channel spectrograph allowing for simultaneous observation of the two orthogonal states of polarization. Although the polarization sensitivity is the most important aspect of the instrument, the spatial and spectral resolutions of the instrument are also crucial to observe the chromospheric features and resolve the Ly-α profiles. A precise alignment of the optics is required to ensure the resolutions, but experiments under vacuum conditions are needed since Ly-α is absorbed by air, making the alignment experiments difficult. To bypass this issue, we developed methods to align the telescope and the spectrograph separately in visible light. We explain these methods and present the results for the optical alignment of the CLASP telescope and spectrograph. We then discuss the combined performances of both parts to derive the expected resolutions of the instrument, and compare them with the flight observations performed on September 3rd 2015.
Chiu, Shao-Chih; Chen, Jo-Mei Maureen; Wei, Tong-You Wade; Cheng, Tai-Shan; Wang, Ya-Hui Candice; Ku, Chia-Feng; Lian, Chiao-Hsuan; Liu, Chun-Chih Jared; Kuo, Yi-Chun; Yu, Chang-Tze Ricky
2014-09-01
Cells display dramatic morphological changes in mitosis, where numerous factors form regulatory networks to orchestrate the complicated process, resulting in extreme fidelity of the segregation of duplicated chromosomes into two daughter cells. Astrin regulates several aspects of mitosis, such as maintaining the cohesion of sister chromatids by inactivating Separase and stabilizing spindle, aligning and segregating chromosomes, and silencing spindle assembly checkpoint by interacting with Src kinase-associated phosphoprotein (SKAP) and cytoplasmic linker-associated protein-1α (CLASP-1α). To understand how Astrin is regulated in mitosis, we report here that Astrin acts as a mitotic phosphoprotein, and Aurora-A phosphorylates Astrin at Ser(115). The phosphorylation-deficient mutant Astrin S115A abnormally activates spindle assembly checkpoint and delays mitosis progression, decreases spindle stability, and induces chromosome misalignment. Mechanistic analyses reveal that Astrin phosphorylation mimicking mutant S115D, instead of S115A, binds and induces ubiquitination and degradation of securin, which sequentially activates Separase, an enzyme required for the separation of sister chromatids. Moreover, S115A fails to bind mitosis regulators, including SKAP and CLASP-1α, which results in the mitotic defects observed in Astrin S115A-transfected cells. In conclusion, Aurora-A phosphorylates Astrin and guides the binding of Astrin to its cellular partners, which ensures proper progression of mitosis. Copyright © 2014 the American Physiological Society.
Structure and immune recognition of trimeric pre-fusion HIV-1 Env
Pancera, Marie; Zhou, Tongqing; Druz, Aliaksandr; ...
2014-10-08
The human immunodeficiency virus type 1 (HIV-1) envelope (Env) spike, comprising three gp120 and three gp41 subunits, is a conformational machine that facilitates HIV-1 entry by rearranging from a mature unliganded state, through receptor-bound intermediates, to a post-fusion state. As the sole viral antigen on the HIV-1 virion surface, Env is both the target of neutralizing antibodies and a focus of vaccine efforts. Here we report the structure at 3.5 Å resolution for an HIV-1 Env trimer captured in a mature closed state by antibodies PGT122 and 35O22. This structure reveals the pre-fusion conformation of gp41, indicates rearrangements needed formore » fusion activation, and defines parameters of immune evasion and immune recognition. Pre-fusion gp41 encircles amino- and carboxy-terminal strands of gp120 with four helices that form a membrane-proximal collar, fastened by insertion of a fusion peptide-proximal methionine into a gp41-tryptophan clasp. Spike rearrangements required for entry involve opening the clasp and expelling the termini. In conclusion, N-linked glycosylation and sequence-variable regions cover the pre-fusion closed spike; we used chronic cohorts to map the prevalence and location of effective HIV-1-neutralizing responses, which were distinguished by their recognition of N-linked glycan and tolerance for epitope-sequence variation.« less
Structure and immune recognition of trimeric pre-fusion HIV-1 Env
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pancera, Marie; Zhou, Tongqing; Druz, Aliaksandr
The human immunodeficiency virus type 1 (HIV-1) envelope (Env) spike, comprising three gp120 and three gp41 subunits, is a conformational machine that facilitates HIV-1 entry by rearranging from a mature unliganded state, through receptor-bound intermediates, to a post-fusion state. As the sole viral antigen on the HIV-1 virion surface, Env is both the target of neutralizing antibodies and a focus of vaccine efforts. Here we report the structure at 3.5 Å resolution for an HIV-1 Env trimer captured in a mature closed state by antibodies PGT122 and 35O22. This structure reveals the pre-fusion conformation of gp41, indicates rearrangements needed formore » fusion activation, and defines parameters of immune evasion and immune recognition. Pre-fusion gp41 encircles amino- and carboxy-terminal strands of gp120 with four helices that form a membrane-proximal collar, fastened by insertion of a fusion peptide-proximal methionine into a gp41-tryptophan clasp. Spike rearrangements required for entry involve opening the clasp and expelling the termini. In conclusion, N-linked glycosylation and sequence-variable regions cover the pre-fusion closed spike; we used chronic cohorts to map the prevalence and location of effective HIV-1-neutralizing responses, which were distinguished by their recognition of N-linked glycan and tolerance for epitope-sequence variation.« less
Nonrandom γ-TuNA-dependent spatial pattern of microtubule nucleation at the Golgi
Sanders, Anna A. W. M.; Chang, Kevin; Zhu, Xiaodong; Thoppil, Roslin J.; Holmes, William R.; Kaverina, Irina
2017-01-01
Noncentrosomal microtubule (MT) nucleation at the Golgi generates MT network asymmetry in motile vertebrate cells. Investigating the Golgi-derived MT (GDMT) distribution, we find that MT asymmetry arises from nonrandom nucleation sites at the Golgi (hotspots). Using computational simulations, we propose two plausible mechanistic models of GDMT nucleation leading to this phenotype. In the “cooperativity” model, formation of a single GDMT promotes further nucleation at the same site. In the “heterogeneous Golgi” model, MT nucleation is dramatically up-regulated at discrete and sparse locations within the Golgi. While MT clustering in hotspots is equally well described by both models, simulating MT length distributions within the cooperativity model fits the data better. Investigating the molecular mechanism underlying hotspot formation, we have found that hotspots are significantly smaller than a Golgi subdomain positive for scaffolding protein AKAP450, which is thought to recruit GDMT nucleation factors. We have further probed potential roles of known GDMT-promoting molecules, including γ-TuRC-mediated nucleation activator (γ-TuNA) domain-containing proteins and MT stabilizer CLASPs. While both γ-TuNA inhibition and lack of CLASPs resulted in drastically decreased GDMT nucleation, computational modeling revealed that only γ-TuNA inhibition suppressed hotspot formation. We conclude that hotspots require γ-TuNA activity, which facilitates clustered GDMT nucleation at distinct Golgi sites. PMID:28931596
NASA Astrophysics Data System (ADS)
Hardy, Luke A.; Hutchens, Thomas C.; Larson, Eric R.; Gonzalez, David A.; Chang, Chun-Hung; Nau, William H.; Fried, Nathaniel M.
2017-05-01
Energy-based, radiofrequency (RF) and ultrasonic (US) devices currently provide rapid sealing of blood vessels during laparoscopic procedures. We are exploring infrared lasers as an alternate energy modality for vessel sealing, capable of generating less collateral thermal damage. Previous studies demonstrated feasibility of sealing vessels in an in vivo porcine model using a 1470-nm laser. However, the initial prototype was designed for testing in open surgery and featured tissue clasping and light delivery mechanisms incompatible with laparoscopic surgery. In this study, a laparoscopic prototype similar to devices currently in surgical use was developed, and performance tests were conducted on porcine renal blood vessels, ex vivo. The 5-mm outer-diameter laparoscopic prototype featured a traditional Maryland jaw configuration that enables tissue manipulation and blunt dissection. Laser energy was delivered through a 550-μm-core-diameter optical fiber with side-delivery from the lower jaw and beam dimensions of 18-mm length×1.2-mm width. The 1470-nm diode laser delivered 68 W with 3-s activation time, consistent with vessel seal times associated with RF and US-based devices. A total of 69 fresh porcine renal vessels with mean diameter of 3.3±1.7 mm were tested, ex vivo. Vessels smaller than 5-mm diameter were consistently sealed (48/51) with burst pressures greater than malignant hypertension blood pressure (180 mmHg), averaging 1038±474 mmHg. Vessels larger than 5 mm were not consistently sealed (6/18), yielding burst pressures of only 174±221 mmHg. Seal width, thermal damage zone, and thermal spread averaged 1.7±0.8, 3.4±0.7, and 1.0±0.4 mm, respectively. Results demonstrated that the 5-mm optical laparoscopic prototype consistently sealed vessels less than 5-mm diameter with low thermal spread. Further in vivo studies are planned to test the performance across a variety of vessels and tissues.
Development of a KSC test and flight engineering oriented computer language, Phase 1
NASA Technical Reports Server (NTRS)
Case, C. W.; Kinney, E. L.; Gyure, J.
1970-01-01
Ten, primarily test oriented, computer languages reviewed during the phase 1 study effort are described. Fifty characteristics of ATOLL, ATLAS, and CLASP are compared. Unique characteristics of the other languages, including deficiencies, problems, safeguards, and checking provisions are identified. Programming aids related to these languages are reported, and the conclusions resulting from this phase of the study are discussed. A glossary and bibliography are included. For the reports on phase 2 of the study, see N71-35027 and N71-35029.
Kirchhoff, H
1990-03-01
The artistic representation of the female breasts is based upon two totally independent concepts, which are different in their expression. On the one hand, the figure, clasping her hands around her breasts, stands for womanliness and fertility. On the other hand, the act of voiding milk or water, symbolizes donation of or wisdom. These two functions of the female breasts are a large number of illustrations.
2011-11-01
SAS Institute Inc., Cary , NC, USA. Wersal, R.M., J.D. Madsen, B.R. McMillan and P.D. Gerard. 2006. Environmental factors affecting biomass and...Eurasian watermilfoil 50 16* 12* Potamogeton crispus Curlyleaf pondweed 81 50* 67 Potamogeton foliosus Leafy pondweed 31 16 42 Potamogeton illinoensis ...foliosus Leafy pondweed 11 0* 19 Potamogeton illinoensis Illinois pondweed 3 0 0 Potamogeton richardsonii Clasping-leaved pondweed 31 3* 3
The clinical spectrum of mutations in L1, a neuronal cell adhesion molecule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fransen, E.; Vits, L.; Van Camp, G.
1996-07-12
Mutations in the gene encoding the neuronal cell adhesion molecule L1 are responsible for several syndromes with clinical overlap, including X-linked hydrocephalus (XLH, HSAS), MASA (mental retardation, aphasia, shuffling gait, adducted thumbs) syndrome, complicated X-linked spastic paraplegia (SP 1), X-linked mental retardation-clasped thumb (MR-CT) syndrome, and some forms of X-linked agenesis of the corpus callosum (ACC). We review 34 L1 mutations in patients with these phenotypes. 22 refs., 3 figs., 4 tabs.
2012-11-28
The next trio of residents that will launch to the International Space Station clasp hands for reporters and photojournalists at the Gagarin Cosmonaut Training Center in Star City, Russia Nov. 28, 2012 during the second of two days of flight qualification exams. Expedition 34/35 Flight Engineer Chris Hadfield of the Canadian Space Agency (left), Soyuz Commander Roman Romanenko (center) and NASA Flight Engineer Tom Marshburn (right) are scheduled to launch Dec. 19 from the Baikonur Cosmodrome in Kazakhstan on the Soyuz TMA-07M spacecraft. NASA/Stephanie Stoll
Laparoscopic prototype for optical sealing of renal blood vessels
NASA Astrophysics Data System (ADS)
Hardy, Luke A.; Hutchens, Thomas C.; Larson, Eric R.; Gonzalez, David A.; Chang, Chun-Hung; Nau, William H.; Fried, Nathaniel M.
2017-02-01
Energy-based, radiofrequency and ultrasonic devices provide rapid sealing of blood vessels during laparoscopic procedures. We are exploring infrared lasers as an alternative for vessel sealing with less collateral thermal damage. Previous studies demonstrated vessel sealing in an in vivo porcine model using a 1470-nm laser. However, the initial prototype was designed for open surgery and featured tissue clasping and light delivery mechanisms incompatible with laparoscopic surgery. In this study, a laparoscopic prototype similar to devices in surgical use was developed, and tests were conducted on porcine renal blood vessels. The 5-mm-OD prototype featured a traditional Maryland jaw configuration. Laser energy was delivered through a 550-μm-core fiber and side-delivery from the lower jaw, with beam dimensions of 18-mm-length x 1.2-mm-width. The 1470-nm diode laser delivered 68 W with 3 s activation time. A total of 69 porcine renal vessels with mean diameter of 3.3 +/- 1.7 mm were tested, ex vivo. Vessels smaller than 5 mm were consistently sealed (48/51) with burst pressures greater than malignant hypertension blood pressure (180 mmHg), averaging 1038 +/- 474 mmHg. Vessels larger than 5 mm were not consistently sealed (6/18), yielding burst pressures of only 174 +/- 221 mmHg. Seal width, thermal damage zone, and thermal spread averaged 1.7 +/- 0.8, 3.4 +/- 0.7, and 1.0 +/- 0.4 mm. A novel optical laparoscopic prototype with 5-mm- OD shaft integrated within a standard Maryland jaw design consistently sealed vessels less than 5 mm with minimal thermal spread. Further in vivo studies are planned to test performance across a variety of vessels and tissues.
ALGORITHM FOR TREATMENT OF PATIENTS WITH MESIAL OCCLUSION USING PROPRIETARY ORTHODONTIC DEVICE.
Flis, P; Filonenko, V; Doroshenko, N
2017-10-01
Early elimination of dentoalveolar apparatus orthodontic disorders is the dominant concept in the treatment technique. to present a sagittal anomalies treatment algorithm, of Class III particularly, in the transitional bite period by the proposed design of individual orthodontic devices with a movable ramp. The treatment algorithm consisted of several blocks: the motivation, the etiological factors establishment, the plan and treatment tactics creation basing on careful diagnosis, the stages of the active period of treatment and the patient management in the retention period. Anthropometric measurements of the maxilla and mandible models were performed to determine the degree of dental arches development. The length of the dental arches was determined on the models by the Nance method in combination with the Huckaba method and the sagital dimensions by the Mirgasizov's method. The leading role in the patients examination was taken by lateral cephalograms analyzing using the Sassouni Plus method. The proposed construction of an orthodontic appliance consists of a plastic base, a vestibular arc, retaining clasps and a ramp, which is connected with a base with two torsion springs. To demonstrate the effectiveness of the proposed construction, an example of the patient Y. treatment of at the age of 6 years 9 months is presented. After the treatment, positive morphological, functional and aesthetic changes were established. The usage of proposed orthodontic appliance with movable ramp allows to start orthodontic treatment at early age, increases its effectiveness and reduce the number of complications. The expediency of stage-by-stage treatment is approved by a positive results of such method. To achieve stable results, it is important to individualize their prognosis even at the planning stage of orthodontic treatment.
Burton, Ronald S.
2017-01-01
Securing a potential mate is one of the most important processes in sexual reproduction of animals. Intertidal copepods of the genus Tigriopus show mate-guarding behavior where a male captures a female and continues to clasp her for up to two weeks prior to copulation. Although these copepods form a mate-guarding pair between a male and a female with high accuracy, interactions between the sexes in pair formation have not been well described and the mechanism allowing successful male-female pair formation is not yet understood. In this study, we performed experiments with Tigriopus californicus to analyze the behavior of both a capturer (male) and a captured individual (female or male) in formation of a guarding pair. While capturer males were attracted by both females and males, capture of virgin males was terminated in a significantly shorter time than that of virgin females. However, when presented freshly killed females or males, regardless of the sex of the body, capturer males continued to clasp the body for a comparable time as in an attempt on a living female. Our results suggest that a sex-specific rejection signal actively sent by captured males prevents male-male pair formation. Experiments also suggest that mated females reject an attempt of pair formation. To our knowledge, this is the first study to suggest involvement of active rejection by a captured individual in facilitation of reproductively successful male-female guarding pair formation in the genus Tigriopus. PMID:28832683
Salamon, Sylwia; Nowacka-Woszuk, Joanna; Szczerbal, Izabela; Dzimira, Stanisław; Nizanski, Wojciech; Ochota, Malgorzata; Switonski, Marek
2014-01-01
A disorder of sexual development (DSD) of dogs with a female karyotype, missing SRY gene, and presence of testicles or ovotestes is quite commonly diagnosed. It is suggested that this disorder is caused by an autosomal recessive mutation; however, other models of inheritance have not been definitely ruled out. In an earlier study it was hypothesized that the mutation may reside in a pericentromeric region of canine chromosome 23 (CFA23). Three positional candidate genes (CLASP2, UBP1, and FBXL2) were selected in silico in the search for polymorphisms in 7 testicular or ovotesticular XX DSD dogs, 8 XX DSD dogs of unknown cause (SRY-negative, with enlarged clitoris and unknown histology of gonads), and 29 normal female dogs as a control group. Among the 15 molecularly studied dogs with enlarged clitoris there were 3 new cases of testicular or ovotesticular XX DSD and 4 new cases of XX DSD with unknown cause (histology of the gonads unknown). Altogether, 11 (including 10 novel) polymorphisms in 5'- and 3'-flanking regions of the studied genes were found. The distribution analysis of these polymorphisms showed no association with the DSD phenotypes. Thus, it was concluded that the presence of the causative mutation for testicular or ovotesticular XX DSD in the pericentromeric region of CFA23 is unlikely. © 2014 S. Karger AG, Basel.
NASA Technical Reports Server (NTRS)
Giono, G.; Katsukawa, Y.; Ishikawa, R.; Narukage, N.; Kano, R.; Kubo, M.; Ishikawa, S.; Bando, T.; Hara, H.; Suematsu, Y.;
2016-01-01
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument developed at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. The in- strument main scientific goal is to achieve polarization measurement of the Lyman-alpha line at 121.56 nm emitted from the solar upper-chromosphere and transition region with an unprecedented 0.1% accuracy. For this purpose, the optics are composed of a Cassegrain telescope coated with a "cold mirror" coating optimized for UV reflection and a dual-channel spectrograph allowing for simultaneous observation of the two orthogonal states of polarization. Although the polarization sensitivity is the most important aspect of the instrument, the spatial and spectral resolutions of the instrument are also crucial to observe the chromospheric features and resolve the Ly- pro les. A precise alignment of the optics is required to ensure the resolutions, but experiments under vacuum conditions are needed since Ly-alpha is absorbed by air, making the alignment experiments difficult. To bypass this issue, we developed methods to align the telescope and the spectrograph separately in visible light. We will explain these methods and present the results for the optical alignment of the CLASP telescope and spectrograph. We will then discuss the combined performances of both parts to derive the expected resolutions of the instrument, and compare them with the flight observations performed on September 3rd 2015.
Discovery of Scattering Polarization in the Hydrogen Lyα Line of the Solar Disk Radiation
NASA Astrophysics Data System (ADS)
Kano, R.; Trujillo Bueno, J.; Winebarger, A.; Auchère, F.; Narukage, N.; Ishikawa, R.; Kobayashi, K.; Bando, T.; Katsukawa, Y.; Kubo, M.; Ishikawa, S.; Giono, G.; Hara, H.; Suematsu, Y.; Shimizu, T.; Sakao, T.; Tsuneta, S.; Ichimoto, K.; Goto, M.; Belluzzi, L.; Štěpán, J.; Asensio Ramos, A.; Manso Sainz, R.; Champey, P.; Cirtain, J.; De Pontieu, B.; Casini, R.; Carlsson, M.
2017-04-01
There is a thin transition region (TR) in the solar atmosphere where the temperature rises from 10,000 K in the chromosphere to millions of degrees in the corona. Little is known about the mechanisms that dominate this enigmatic region other than the magnetic field plays a key role. The magnetism of the TR can only be detected by polarimetric measurements of a few ultraviolet (UV) spectral lines, the Lyα line of neutral hydrogen at 121.6 nm (the strongest line of the solar UV spectrum) being of particular interest given its sensitivity to the Hanle effect (the magnetic-field-induced modification of the scattering line polarization). We report the discovery of linear polarization produced by scattering processes in the Lyα line, obtained with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) rocket experiment. The Stokes profiles observed by CLASP in quiet regions of the solar disk show that the Q/I and U/I linear polarization signals are of the order of 0.1% in the line core and up to a few percent in the nearby wings, and that both have conspicuous spatial variations with scales of ˜10 arcsec. These observations help constrain theoretical models of the chromosphere-corona TR and extrapolations of the magnetic field from photospheric magnetograms. In fact, the observed spatial variation from disk to limb of polarization at the line core and wings already challenge the predictions from three-dimensional magnetohydrodynamical models of the upper solar chromosphere.
Vagal Afferent Innervation of the Lower Esophageal Sphincter
Powley, Terry L.; Baronowsky, Elizabeth A.; Gilbert, Jared M.; Hudson, Cherie N.; Martin, Felecia N.; Mason, Jacqueline K.; McAdams, Jennifer L.; Phillips, Robert J.
2013-01-01
To supply a fuller morphological characterization of the vagal afferents innervating the lower esophageal sphincter (LES), specifically to label vagal terminals in the tissues forming the LES in the gastroesophageal junction, the present experiment employed injections of dextran biotin into the nodose ganglia of rats. Four types of vagal afferents innervated the LES. Clasp and sling muscle fibers were directly and prominently innervated by intramuscular arrays (IMAs). Individual IMA terminals subtended about 16° of arc of the esophageal circumference, and, collectively, the terminal fields were distributed within the muscle ring to establish a 360° annulus of mechanoreceptors in the sphincter wall. 3D morphometry of the terminals established that, compared to sling muscle IMAs, clasp muscle IMAs had more extensive arbors and larger receptive fields. In addition, at the cardia, local myenteric ganglia between smooth muscle sheets and striated muscle bundles were innervated by intraganglionic laminar endings (IGLEs), in a pattern similar to the innervation of the myenteric plexus throughout the stomach and esophagus. Finally, as previously described, the principle bundle of sling muscle fibers that links LES sphincter tissue to the antropyloric region of the lesser curvature was innervated by exceptionally long IMAs as well as by unique web ending specializations at the distal attachment of the bundle. Overall, the specialized varieties of densely distributed vagal afferents innervating the LES underscore the conclusion that these sensory projections are critically involved in generating LES reflexes and may be promising targets for managing esophageal dysfunctions. PMID:23583280
A new species of Fuziidae (Insecta, Blattida) from the Inner Mongolia, China
Wei, Dandan; Liang, Junhui; Ren, Dong
2012-01-01
Abstract A new species attributed to the genus Parvifuzia Guo & Ren, 2011, Parvifuzia peregrina sp. n., is described from the Middle Jurassic Jiulongshan Formation of Daohugou Village, Inner Mongolia, China. This new species, with apex of wing almost reaching the end of the abdomen and forewing venation with 30–32 veins at margin, broadens the diversity of Parvifuzia. This new species, with strongly curved cerci, could tightly clasp female and complete copulation more efficiently, same as other members of the family Fuziidae. PMID:22977342
Hajiqanbar, Hamidreza; Khaustov, Alexander; Kamali, Karim
2011-01-01
A new species of the genus Parapygmephorus Cross, 1965 (Acari: Heterostigmatina, Neopygmephoridae) is described from Northeastern Iran. A phoretic adult female of Parapygmephorus khorasanicus Hajiqanbar and Khaustov sp. n. was discovered clasping on hairs on the ventral body surface of Halictus quadricinctus (Fabricius, 1776) (Hymenoptera; Halictidae). It is the fifth representative among the known species of the genus Parapygmephorus in the world. Differentiation of new species from other species of the genus is discussed, and a key to known world species is provided.
Inventory Optimization of USMC Uniforms Through Reverse Logistics
2016-05-01
Blouse, Desert, MCCUU wiPermethrin 3 $ 38.86 $ 116.58 8415-01-527-1430 03092 Blouse, Woodland, MCCUU wiPermethrin 2 $ 38.90 $ 77.80 8430-01-591· 1103 ...1 $ 11.66 $ 11.66 8455-01-503- 1103 10054 Clasp, Necktie, Gold Plated 1 $ 1.46 $ 1.46 8405-01-279-5579 02049 Coat, Man’s PolyiWool Gabardne, Green. w...Woodland, MCCUU wiPermethrin 2 $ 38.90 $ 77.80 8430-01-591· 1103 04094 Boot, Rugged All Terrain (RAT), Hot Weather $ 141.70 $ 141.70 8430-01-563-6897 03544
Evaluation of Meteorological and Aerosol Sensing with small Unmanned Aerial Systems
NASA Astrophysics Data System (ADS)
Claussen, Johanna; Möhler, Ottmar; Leisner, Thomas; Brooks, Ian; Norris, Sarah; Brooks, Barbara; Hill, Martin; Haunold, Werner; Schrod, Jann; Danielczok, Anja
2013-04-01
Atmospheric aerosols have a large impact on the climate system due to their influence on the global radiation budget. Local aerosol sources such as vegetation, (bare) soil or industrial sites have to be quantified with high resolution data to validate aerosol transport models and improve the input for high resolution weather models. Our goal is to evaluate the use of Unmanned Aerial Systems (UAS) as a method for acquisition of high resolution meteorological and aerosol data. During the INUIT measurement campaign in August 2012 at mount Großer Feldberg near Frankfurt, Germany, several flights with different sensor packages were carried out. We measured basic meteorological parameters such as temperature, relative humidity and air pressure with miniaturized onboard sensors. In addition, the Compact Lightweight Aerosol Spectrometer Probe (CLASP) for aerosol size distribution measurement or the Electrostatic Aerosol Collector (EAC) for aerosol sample collection was installed on board. CLASP measures aerosol particles with diameters from 0.17 μm to 9.5 μm in up to 32 channels at a frequency of 10 Hz. The EAC collects air samples at 2 l/min onto a sample holder. After the flight the ice nuclei on the sample holder are activated and counted in the isothermal static diffusion chamber FRIDGE. The results from the INUIT campaign and additional calibration laboratory measurements show that UAS are a valuable platform for miniaturized sensors. The number of ice nuclei was determined with the EAC at 200m above ground level and compared to the reference measurement on the ground.
Therapeutic Effects of Anthocyanins and Environmental Enrichment in R6/1 Huntington's Disease Mice.
Kreilaus, Fabian; Spiro, Adena S; Hannan, Anthony J; Garner, Brett; Jenner, Andrew M
2016-10-01
Huntington's disease (HD) is a progressive neurodegenerative disease with no effective treatment or cure. Environmental enrichment has been used to slow processes leading to ageing and neurodegenerative diseases including HD. Phenolic phytochemicals including anthocyanins have also been shown to improve brain function in ageing and neurodegenerative diseases. This study examined the effects of anthocyanin dietary supplementation and environmental enrichment on behavioural phenotypes and brain cholesterol metabolic alterations in the R6/1 mouse model of HD. R6/1 HD mice and their wild-type littermate controls were randomised into the different experimental conditions, involving either environmentally enriched versus standard housing conditions, or anthocyanin versus control diet. Motor dysfunction was assessed from 6 to 26 weeks using the RotaRod and the hind-paw clasping tests. Gas chromatography - tandem mass spectrometry was used to quantify a broad range of sterols in the striatum and cortex of R6/1 HD mice. Anthocyanin dietary supplementation delayed the onset of motor dysfunction in female HD mice. Environmental enrichment improved motor function and the hind paw clasping phenotype in male HD mice only. These mice also had lower levels of cholesterol oxidation products in the cortex compared to standard-housed mice. Both anthocyanin supplementation and environmental enrichment are able to improve the motor dysfunction phenotype of R6/1 mice, however the effectiveness of these interventions was different between the two sexes. The interventions examined did not alter brain cholesterol metabolic deficits that have been reported previously in this mouse model of HD.
Discovery of Scattering Polarization in the Hydrogen Ly α Line of the Solar Disk Radiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kano, R.; Narukage, N.; Ishikawa, R.
There is a thin transition region (TR) in the solar atmosphere where the temperature rises from 10,000 K in the chromosphere to millions of degrees in the corona. Little is known about the mechanisms that dominate this enigmatic region other than the magnetic field plays a key role. The magnetism of the TR can only be detected by polarimetric measurements of a few ultraviolet (UV) spectral lines, the Ly α line of neutral hydrogen at 121.6 nm (the strongest line of the solar UV spectrum) being of particular interest given its sensitivity to the Hanle effect (the magnetic-field-induced modification ofmore » the scattering line polarization). We report the discovery of linear polarization produced by scattering processes in the Ly α line, obtained with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) rocket experiment. The Stokes profiles observed by CLASP in quiet regions of the solar disk show that the Q / I and U / I linear polarization signals are of the order of 0.1% in the line core and up to a few percent in the nearby wings, and that both have conspicuous spatial variations with scales of ∼10 arcsec. These observations help constrain theoretical models of the chromosphere–corona TR and extrapolations of the magnetic field from photospheric magnetograms. In fact, the observed spatial variation from disk to limb of polarization at the line core and wings already challenge the predictions from three-dimensional magnetohydrodynamical models of the upper solar chromosphere.« less
Rendón-Ramírez, Adela; Shukla, Manish; Oda, Masataka; Chakraborty, Sandeep; Minda, Renu; Dandekar, Abhaya M; Ásgeirsson, Bjarni; Goñi, Félix M; Rao, Basuthkar J
2013-01-01
Proteolytic enzymes have evolved several mechanisms to cleave peptide bonds. These distinct types have been systematically categorized in the MEROPS database. While a BLAST search on these proteases identifies homologous proteins, sequence alignment methods often fail to identify relationships arising from convergent evolution, exon shuffling, and modular reuse of catalytic units. We have previously established a computational method to detect functions in proteins based on the spatial and electrostatic properties of the catalytic residues (CLASP). CLASP identified a promiscuous serine protease scaffold in alkaline phosphatases (AP) and a scaffold recognizing a β-lactam (imipenem) in a cold-active Vibrio AP. Subsequently, we defined a methodology to quantify promiscuous activities in a wide range of proteins. Here, we assemble a module which encapsulates the multifarious motifs used by protease families listed in the MEROPS database. Since APs and proteases are an integral component of outer membrane vesicles (OMV), we sought to query other OMV proteins, like phospholipase C (PLC), using this search module. Our analysis indicated that phosphoinositide-specific PLC from Bacillus cereus is a serine protease. This was validated by protease assays, mass spectrometry and by inhibition of the native phospholipase activity of PI-PLC by the well-known serine protease inhibitor AEBSF (IC50 = 0.018 mM). Edman degradation analysis linked the specificity of the protease activity to a proline in the amino terminal, suggesting that the PI-PLC is a prolyl peptidase. Thus, we propose a computational method of extending protein families based on the spatial and electrostatic congruence of active site residues.
Sigvardt, Zandra M S; Rogers, D Christopher; Olesen, Jørgen
2017-04-01
Male clam shrimps (Crustacea: Branchiopoda: Laevicaudata, Spinicaudata, and Cyclestherida) have their first one or two trunk limb pairs modified as "claspers," which are used to hold the female during mating and mate guarding. Clasper morphology has traditionally been important for clam shrimp taxonomy and classification, but little is known about how the males actually use the claspers during amplexus (clasping). Homologies of the various clasper parts ("movable finger," "large palp," "palm," "gripping area," and "small palp") have long been discussed between the three clam shrimp taxa, and studies have shown that only some structures are homologous while others are convergent ("partial homology"). We studied the clasper functionality in four spinicaudatan species using video recordings and scanning electron microscopy, and compared our results with other clam shrimp groups. General mating behavior and carapace morphology was also studied. Generally, spinicaudatan and laevicaudatan claspers function similarly despite some parts being nonhomologous. We mapped clasper morphology and functionality aspects on a branchiopod phylogeny. We suggest that the claspers of the three groups were adapted from an original, simpler clasper, each for a "stronger" grip on the female's carapace margin: 1) Spinicaudata have two clasper pairs bearing an elongated apical club/gripping area with one setal type; 2); Cyclestherida have one clasper pair with clusters of molariform setae on the gripping area and at the movable finger apex; and 3) Laevicaudata have one clasper pair, but have incorporated an additional limb portion into the clasper palm and bear a diverse set of setae. J. Morphol. 278:523-546, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Salanenka, Yuliya; Verstraeten, Inge; Löfke, Christian; Tabata, Kaori; Naramoto, Satoshi; Glanc, Matouš; Friml, Jiří
2018-01-01
The plant hormone gibberellic acid (GA) is a crucial regulator of growth and development. The main paradigm of GA signaling puts forward transcriptional regulation via the degradation of DELLA transcriptional repressors. GA has also been shown to regulate tropic responses by modulation of the plasma membrane incidence of PIN auxin transporters by an unclear mechanism. Here we uncovered the cellular and molecular mechanisms by which GA redirects protein trafficking and thus regulates cell surface functionality. Photoconvertible reporters revealed that GA balances the protein traffic between the vacuole degradation route and recycling back to the cell surface. Low GA levels promote vacuolar delivery and degradation of multiple cargos, including PIN proteins, whereas high GA levels promote their recycling to the plasma membrane. This GA effect requires components of the retromer complex, such as Sorting Nexin 1 (SNX1) and its interacting, microtubule (MT)-associated protein, the Cytoplasmic Linker-Associated Protein (CLASP1). Accordingly, GA regulates the subcellular distribution of SNX1 and CLASP1, and the intact MT cytoskeleton is essential for the GA effect on trafficking. This GA cellular action occurs through DELLA proteins that regulate the MT and retromer presumably via their interaction partners Prefoldins (PFDs). Our study identified a branching of the GA signaling pathway at the level of DELLA proteins, which, in parallel to regulating transcription, also target by a nontranscriptional mechanism the retromer complex acting at the intersection of the degradation and recycling trafficking routes. By this mechanism, GA can redirect receptors and transporters to the cell surface, thus coregulating multiple processes, including PIN-dependent auxin fluxes during tropic responses. PMID:29463731
Dreshaj, Shemsedin; Alija, Avdulla J; Schlagenhauf, Patricia; Doda, Teuta; Geca, Njomeza; Bajraktari, Ismet; Bresgen, Nikolaus; Eckl, Peter M
Host genetic factors may impact susceptibility to infection. A small number of studies have investigated the association between factors such as ABO blood groups and selected phenotypes on the incidence and severity of H1N1 infections with inconclusive results. Using data from the Clinic of Infectious Diseases - University Clinical Centre Prishtina and based on the examination of 125 patients hospitalized with H1N1 in the period 2009-2014, the frequency of blood groups from ABO and Rhesus (Rh) systems as phenotypical markers were evaluated. In addition, other phenotypes such as ear lobe free/ear lobe attached, normal chin/cleft chin, tongue roller/non roller, hand clasping right thumb over/hand clasping left thumb over, right-handed/left-handed, dark eyes/light eyes were also analyzed. The data obtained from the 125 hospitalized patients were compared with the data from the Kosovar population (n = 2000) as a reference group. A total of 303 patients with H1N1 were hospitalized in the period 2009-2015. Blood group and phenotype data available from 125 hospitalized H1N1 patients showed significant differences in the frequencies of the blood groups from Rh system as well as in two (out of six) phenotypes of the selected morphological traits compared to reference groups. The findings from this preliminary study indicate that these Rh system and phenotype differences may be linked to H1N1 susceptibility and may guide identification of risk groups and populations. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ontogeny of a social custom in wild chimpanzees: age changes in grooming hand-clasp at Mahale.
Nakamura, Michio; Nishida, Toshisada
2013-02-01
Among cultural behaviors of chimpanzees, the developmental processes of complex skills involved in tool use are relatively well known. However, few studies have examined the ontogeny of social customs that do not require complex skills. Thus, in this study, we describe the developmental process of the grooming hand-clasp (GHC), one of the well-known social customs of chimpanzees at Mahale. We have collected 383 cases of GHC where at least one of the participants was 15 years old or younger during 1994-2007. First performances of GHC with the mother were observed at around 4-6 years old; the earliest observed age was 4 years and 4 months old. The first performances of GHC with nonrelated females were at around age 9 years, and those with adult males at around 11 years. However, some orphans engaged in GHC earlier than nonorphans. By gradually expanding GHC partners from the mother to other females and then to males, chimpanzees increased the number of GHC partners with age. Young males were observed to perform GHC with larger numbers of partners than were young females. GHC by young chimpanzees was shorter in duration than that among adults. Overall, the ontogeny of GHC showed several dissimilarities with that of tool use and was more an extension of the development of typical grooming behavior. For example, infants did not try to perform GHC initially; instead, mothers were more active in the earliest stages. These results suggest that not all socially learned cultural behaviors are acquired in the way of learning tool use. There may be various ways of learning behavioral patterns that are performed continuously in a group and that consequently comprise culture in chimpanzees. © 2012 Wiley Periodicals, Inc.
Nonrandom γ-TuNA-dependent spatial pattern of microtubule nucleation at the Golgi.
Sanders, Anna A W M; Chang, Kevin; Zhu, Xiaodong; Thoppil, Roslin J; Holmes, William R; Kaverina, Irina
2017-11-07
Noncentrosomal microtubule (MT) nucleation at the Golgi generates MT network asymmetry in motile vertebrate cells. Investigating the Golgi-derived MT (GDMT) distribution, we find that MT asymmetry arises from nonrandom nucleation sites at the Golgi (hotspots). Using computational simulations, we propose two plausible mechanistic models of GDMT nucleation leading to this phenotype. In the "cooperativity" model, formation of a single GDMT promotes further nucleation at the same site. In the "heterogeneous Golgi" model, MT nucleation is dramatically up-regulated at discrete and sparse locations within the Golgi. While MT clustering in hotspots is equally well described by both models, simulating MT length distributions within the cooperativity model fits the data better. Investigating the molecular mechanism underlying hotspot formation, we have found that hotspots are significantly smaller than a Golgi subdomain positive for scaffolding protein AKAP450, which is thought to recruit GDMT nucleation factors. We have further probed potential roles of known GDMT-promoting molecules, including γ-TuRC-mediated nucleation activator (γ-TuNA) domain-containing proteins and MT stabilizer CLASPs. While both γ-TuNA inhibition and lack of CLASPs resulted in drastically decreased GDMT nucleation, computational modeling revealed that only γ-TuNA inhibition suppressed hotspot formation. We conclude that hotspots require γ-TuNA activity, which facilitates clustered GDMT nucleation at distinct Golgi sites. © 2017 Sanders et al. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).
Revazov, A A; Pasekov, V P; Lukasheva, I D
1975-01-01
The paper deals with the distribution of genetic markers (systems ABO, MN, Rh (D), Hp, PTC) and a number of demographic (folding of arms, hand clasping, tongue rolling, right- and left-handedness, of the type of ear lobe, of the types of dermatoglyphic patterns) in the inhabitants of 6 villages in the Mezen District of the Archangelsk Region of the RSFSR (river Peosa basin). The data presented in this work were obtained in the course of examination of over 800 persons. Differences in the interpretation of the results of generally adopted methods of statistical analysis of samples from small populations are discussed. Among the systems analysed in one third of all the cases there was a statistically significant deviation from Hardy-Weinberg's ratios. For the MN blood groups and haptoglobins this was caused by the excess of heterozygotes. The test of Hardy--Weinberg's ratios at the level of two-loci phenotypes revealed no statistically significant deviations either in separate villages or in all the villages taken together. The analysis of heterogeneity with respect to markers inherited according to Mendel's law revealed statistically significant differences between villages in all the systems except haptoglobins. A considerable heterogeneity in the distribution of family names, the frequencies of some of them varying from village to village from 0 to 90%. Statistically significant differences between villages were shown for all the anthropogenetic characters except arm folding, hand clasping and right-left-handedness. Considering the uniformity of the environmental pressure in the region examined, the heterogeneity of the population studied is apparently associated with a random genetic differentiation (genetic drift) and, possibly, with the effect of the progenitor.
Zipper Connectors for Flexible Electronic Circuits
NASA Technical Reports Server (NTRS)
Barnes, Kevin N.
2003-01-01
Devices that look and function much like conventional zippers on clothing have been proposed as connectors for flexible electronic circuits. Heretofore, flexible electronic circuits have commonly included rigid connectors like those of conventional rigid electronic circuits. The proposed zipper connectors would make it possible to connect and disconnect flexible circuits quickly and easily. Moreover, the flexibility of zipper connectors would make them more (relative to rigid connectors) compatible with flexible circuits, so that the advantages of flexible circuitry could be realized more fully. Like a conventional zipper, a zipper according to the proposal would include teeth anchored on flexible tapes, a slider with a loosely attached clasp, a box at one end of the rows of mating teeth, and stops at the opposite ends. The tapes would be made of a plastic or other dielectric material. On each of the two mating sides of the zipper, metal teeth would alternate with dielectric (plastic) teeth, there being two metal teeth for each plastic one. When the zipper was closed, each metal tooth from one side would be in mechanical and electrical contact with a designated metal tooth from the other side, and these mating metal teeth would be electrically insulated from the next pair of mating metal teeth by an intervening plastic tooth. The metal teeth would be soldered or crimped to copper tabs. Wires or other conductors connected to electronic circuits would be soldered or crimped to the ends of the tabs opposite the teeth.
Sounding Rocket Instrument Development at UAHuntsville/NASA MSFC
NASA Technical Reports Server (NTRS)
Kobayashi, Ken; Cirtain, Jonathan; Winebarger, Amy; Savage, Sabrina; Golub, Leon; Korreck, Kelly; Kuzin, Sergei; Walsh, Robert; DeForest, Craig; DePontieu, Bart;
2013-01-01
We present an overview of solar sounding rocket instruments developed jointly by NASA Marshall Space Flight Center and the University of Alabama in Huntsville. The High Resolution Coronal Imager (Hi-C) is an EUV (19.3 nm) imaging telescope which was flown successfully in July 2012. The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a Lyman Alpha (121.6 nm) spectropolarimeter developed jointly with the National Astronomical Observatory of Japan and scheduled for launch in 2015. The Marshall Grazing Incidence X-ray Spectrograph is a soft X-ray (0.5-1.2 keV) stigmatic spectrograph designed to achieve 5 arcsecond spatial resolution along the slit.
Flexibility and hardness of dental stainless steel wrought wires used in Thailand.
Benjakul, P; Cheunarrom, C; Ongthiemsak, C
2001-03-01
Stainless steel wrought wires used as clasp arms for removable partial dentures in Thailand were compared with those used in some other countries (in the as-received condition) in terms of flexibility, Vickers microhardness and composition. The results showed that there were significant differences (P< or =0.05) among the wires. A Japanese stainless steel wire (SK) was obviously different from the others. It had the lowest proportional limit and microhardness, but its flexibility was almost the same. The chemical composition of each wire was not greatly different. The wires were about 18-20 wt% chromium and 8-9 wt% nickel, except for the SK wire, which had about 12 wt% nickel.
Polarizers tuned at key far-UV spectral lines for space instrumentation
NASA Astrophysics Data System (ADS)
Larruquert, Juan I.; Malvezzi, A. Marco; Rodríguez-de Marcos, Luis; Giglia, Angelo; Gutiérrez-Luna, Nuria; Espinosa-Yáñez, Lucía.; Honrado-Benítez, Carlos; Aznárez, José A.; Massone, Giuseppe; Capobianco, Gerardo; Fineschi, Silvano; Nannarone, Stefano
2017-05-01
Polarimetry is a valuable technique to help us understand the role played by the magnetic field of the coronal plasma in the energy transfer processes from the inner parts of the Sun to the outer space. Polarimetry in the far ultraviolet (FUV: 100-200 nm), which must be performed from space due to absorption in terrestrial atmosphere, supplies fundamental data of processes that are governed by the Doppler and Hanle effects on resonantly scattered line-emission. To observe these processes there are various key spectral lines in the FUV, from which H I Lyman α (121.6 nm) is the strongest one. Hence some solar physics missions that have been proposed or are under development plan to perform polarimetry at 121.6 nm, like the suborbital missions CLASP I (2015) and CLASP II (2018), and the proposed solar missions SolmeX and COMPASS and stellar mission Arago. Therefore, the development of efficient FUV linear polarizers may benefit these and other possible future missions. C IV (155 nm) and Mg II (280 nm) are other spectral lines relevant for studies of solar and stellar magnetized atmospheres. High performance polarizers can be obtained with optimized coatings. Interference coatings can tune polarizers at the spectral line(s) of interest for solar and stellar physics. Polarizing beamsplitters consist in polarizers that separate one polarization component by reflection and the other by transmission, which enables observing the two polarization components simultaneously with a single polarizer. They involve the benefit of a higher efficiency in collection of polarization data due to the use of a single polarizer for the two polarization components and they may also facilitate a simplified design for a space polarimeter. We present results on polarizing beamsplitters tuned either at 121.6 nm or at the pair of 155 and 280 nm spectral lines.
Willaert, Bert; Suyesh, Robin; Garg, Sonali; Giri, Varad B; Bee, Mark A; Biju, S D
2016-01-01
Anurans show the highest diversity in reproductive modes of all vertebrate taxa, with a variety of associated breeding behaviours. One striking feature of anuran reproduction is amplexus. During this process, in which the male clasps the female, both individuals' cloacae are juxtaposed to ensure successful external fertilization. Several types of amplexus have evolved with the diversification of anurans, and secondary loss of amplexus has been reported in a few distantly related taxa. Within Nyctibatrachus, a genus endemic to the Western Ghats of India, normal axillary amplexus, a complete loss of amplexus, and intermediate forms of amplexus have all been suggested to occur, but many species remain unstudied. Here, we describe the reproductive behaviour of N. humayuni, including a new type of amplexus. The dorsal straddle, here defined as a loose form of contact in which the male sits on the dorsum of the female prior to oviposition but without clasping her, is previously unreported for anurans. When compared to known amplexus types, it most closely resembles the form of amplexus observed in Mantellinae. Furthermore, we prove that, opposed to the situation in most anurans, male semen release happens before egg deposition. We hypothesize that the male ejaculates on the female's dorsum and that sperm subsequently runs from her back and hind legs before fertilizing the eggs. A second feature characterizing anuran breeding is the advertisement call, mostly produced solely by males. Despite recent descriptions of several new Nyctibatrachus species, few studies have explored their vocal repertoire. We describe both the male advertisement call and a female call for N. humayuni. The presence of a female call has not been reported within Nyctibatrachidae, and has been reported in less than 0.5% of anuran species. Altogether, our results highlight a striking diversity and several unique aspects of Nyctibatrachus breeding behaviour.
Zhang, Jingping; Saur, Taixiang; Duke, Angela N; Grant, Seth G N; Platt, Donna M; Rowlett, James K; Isacson, Ole; Yao, Wei-Dong
2014-01-01
Excessive activation of the N-methyl-d-aspartate (NMDA) receptor and the neurotransmitter dopamine (DA) mediate neurotoxicity and neurodegeneration under many neurological conditions, including Huntington's disease (HD), an autosomal dominant neurodegenerative disease characterized by the preferential loss of medium spiny projection neurons (MSNs) in the striatum. PSD-95 is a major scaffolding protein in the postsynaptic density (PSD) of dendritic spines, where a classical role for PSD-95 is to stabilize glutamate receptors at sites of synaptic transmission. Our recent studies indicate that PSD-95 also interacts with the D1 DA receptor localized in spines and negatively regulates spine D1 signaling. Moreover, PSD-95 forms ternary protein complexes with D1 and NMDA receptors, and plays a role in limiting the reciprocal potentiation between both receptors from being escalated. These studies suggest a neuroprotective role for PSD-95. Here we show that mice lacking PSD-95, resulting from genetic deletion of the GK domain of PSD-95 (PSD-95-ΔGK mice), sporadically develop progressive neurological impairments characterized by hypolocomotion, limb clasping, and loss of DARPP-32-positive MSNs. Electrophysiological experiments indicated that NMDA receptors in mutant MSNs were overactive, suggested by larger, NMDA receptor-mediated miniature excitatory postsynaptic currents (EPSCs) and higher ratios of NMDA- to AMPA-mediated corticostriatal synaptic transmission. In addition, NMDA receptor currents in mutant cortical neurons were more sensitive to potentiation by the D1 receptor agonist SKF81297. Finally, repeated administration of the psychostimulant cocaine at a dose regimen not producing overt toxicity-related phenotypes in normal mice reliably converted asymptomatic mutant mice to clasping symptomatic mice. These results support the hypothesis that deletion of PSD-95 in mutant mice produces concomitant overactivation of both D1 and NMDA receptors that makes neurons more susceptible to NMDA excitotoxicity, causing neuronal damage and neurological impairments. Understanding PSD-95-dependent neuroprotective mechanisms may help elucidate processes underlying neurodegeneration in HD and other neurological disorders.
Manafò, Elizabeth; Petermann, Lisa; Lobb, Rebecca; Keen, Deb; Kerner, Jon
2011-01-01
To describe the development stages of the Coalitions Linking Action and Science for Prevention (CLASP) initiative of the Canadian Partnership Against Cancer to support research, practice, and policy coalitions focused on cancer and chronic disease prevention in Canada. Coalitions Linking Action and Science for Prevention was implemented in 3 stages. This article describes Stage 1 that consisted of an online concept-mapping consultation process, 3 topic specific networking and consultation workshops, and 3 context-specific networking, coalition development, and planning meetings. These were all completed using a participatory engagement approach to encourage knowledge exchange across jurisdictions and sectors in Canada. Toronto, Ontario; Calgary, Alberta; Montreal, Québec; and Ottawa, Ontario. More than 500 researchers, practitioners, and policy specialists were invited to take part in the first stage activities. (1) Participant-identified high-priority opportunities for strategic collaboration; (2) Cross-jurisdictional and cross-sector representation; and (3) Participant feedback on the CLASP processes and activities. Participants from Stage 1 activities were distributed across all provinces/territories; 3 jurisdictional levels; and research, practice, and policy sectors. Ninety priority opportunities for strategic collaboration were identified across all 3 workshops. Participants provided detailed feedback about transparency of the RFP (Request for Proposals) application process, support needed to level the playing field for potential applicants, and valuable suggestions for the adjudication process. Coalitions Linking Action and Science for Prevention engaged hundreds of research, practice, and policy experts across Canada focusing social-behavioral, clinical, and environmental and occupational opportunities for cancer and chronic disease prevention. Given the extent of expert and jurisdictional engagement, the substantial Partnership investment in a participatory engagement approach to RFP development and potential applicant response suggests that efforts to link cancer and chronic disease prevention efforts across jurisdictions and through research, practice, and policy collaboration may require this type of a priori investment in networking, communication, coordination, and collaboration.
Suyesh, Robin; Garg, Sonali; Giri, Varad B.; Bee, Mark A.
2016-01-01
Anurans show the highest diversity in reproductive modes of all vertebrate taxa, with a variety of associated breeding behaviours. One striking feature of anuran reproduction is amplexus. During this process, in which the male clasps the female, both individuals’ cloacae are juxtaposed to ensure successful external fertilization. Several types of amplexus have evolved with the diversification of anurans, and secondary loss of amplexus has been reported in a few distantly related taxa. Within Nyctibatrachus, a genus endemic to the Western Ghats of India, normal axillary amplexus, a complete loss of amplexus, and intermediate forms of amplexus have all been suggested to occur, but many species remain unstudied. Here, we describe the reproductive behaviour of N. humayuni, including a new type of amplexus. The dorsal straddle, here defined as a loose form of contact in which the male sits on the dorsum of the female prior to oviposition but without clasping her, is previously unreported for anurans. When compared to known amplexus types, it most closely resembles the form of amplexus observed in Mantellinae. Furthermore, we prove that, opposed to the situation in most anurans, male semen release happens before egg deposition. We hypothesize that the male ejaculates on the female’s dorsum and that sperm subsequently runs from her back and hind legs before fertilizing the eggs. A second feature characterizing anuran breeding is the advertisement call, mostly produced solely by males. Despite recent descriptions of several new Nyctibatrachus species, few studies have explored their vocal repertoire. We describe both the male advertisement call and a female call for N. humayuni. The presence of a female call has not been reported within Nyctibatrachidae, and has been reported in less than 0.5% of anuran species. Altogether, our results highlight a striking diversity and several unique aspects of Nyctibatrachus breeding behaviour. PMID:27326376
Expedition 17 Pre-launch Images from Kazakhstan
2008-04-07
JSC2008-E-032248 (7 April 2008) --- At their crew quarters in Baikonur, Kazakhstan, Expedition 17 Commander Sergei Volkov (center), Flight Engineer Oleg Kononenko (right) and South Korean spaceflight participant So-yeon Yi clasp hands for photographers on April 7, 2008, the eve of their launch to the International Space Station. Volkov, Kononenko and Yi are scheduled to launch to the station on the Soyuz TMA-12 spacecraft from the Baikonur Cosmodrome on April 8 and arrive at the ISS on April 10 to begin what will be six months in space for Volkov and Kononenko. Yi will be in space nine days on the complex, returning to Earth with two of the Expedition 16 crewmembers currently on the station. Photo Credit: NASA /Victor Zelentsov
Expedition Three crew clasp hands for photo at pad
NASA Technical Reports Server (NTRS)
2001-01-01
KENNEDY SPACE CENTER, Fla. -- The Expedition Three crew join hands for a photo on Launch Pad 39A. From left are cosmonaut Vladimir Nikolaevich Dezhurov, Commander Frank Culbertson and cosmonaut Mikhail Tyurin. The STS-105 and Expedition Three crews are at Kennedy Space Center participating in a Terminal Countdown Demonstration Test, a dress rehearsal for launch. The activities include emergency egress training, a simulated launch countdown and familiarization with the payload. Mission STS-105 will be transporting the Expedition Three crew, several payloads and scientific experiments to the International Space Station aboard Space Shuttle Discovery. The Expedition Two crew members currently on the Station will return to Earth on Discovery. The mission is scheduled to launch no earlier than Aug. 9, 2001.
STS-102 MS Helms, Usachev and Voss pose on the FSS at Launch Pad 39B during TCDT
NASA Technical Reports Server (NTRS)
2001-01-01
KENNEDY SPACE CENTER, Fla. -- STS-102 Mission Specialists Susan Helms, Yury Usachev and James Voss clasp hands showing their unity as the Expedition Two crew who will be replacing Expedition One on the International Space Station. Behind them can be seen the tops of the solid rocket booster and external tank on Space Shuttle Discovery. The STS-102 crew is at KSC for Terminal Countdown Demonstration Test activities, which include the emergency training and a simulated launch countdown. STS-102 is the eighth construction flight to the Space Station, with Discovery carrying the Multi-Purpose Logistics Module Leonardo. Expedition One will return to Earth with Discovery. Launch on mission STS-102 is scheduled for March 8.
Observational Consequences of Coronal Heating Mechanisms
NASA Technical Reports Server (NTRS)
Winebarger, Amy R.; Cirtain, Jonathan C.; Golub, Leon; Kobayashi, Ken
2014-01-01
The coronal heating problem remains unsolved today, 80 years after its discovery, despite 50 years of suborbital and orbital coronal observatories. Tens of theoretical coronal heating mechanisms have been suggested, but only a few have been able to be ruled out. In this talk, we will explore the reasons for the slow progress and discuss the measurements that will be needed for potential breakthrough, including imaging the solar corona at small spatial scales, measuring the chromospheric magnetic fields, and detecting the presence of high temperature, low emission measure plasma. We will discuss three sounding rocket instruments developed to make these measurements: the High resolution Resolution Coronal Imager (Hi-C), the Chromospheric Lyman-Alpha Spectropolarimeter (CLASP), and the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS).
New Instruments to Isolate the Coronal Heating Mechanism
NASA Technical Reports Server (NTRS)
Winebarger, Amy
2014-01-01
The coronal heating problem remains unsolved today, 80 years after its discovery, despite 50 years of suborbital and orbital coronal observatories. Tens of theoretical coronal heating mechanisms have been suggested, but only a few have been able to be ruled out. In this talk, we will explore the reasons for the slow progress and discuss the measurements that will be needed for potential breakthrough, including imaging the solar corona at small spatial scales, measuring the chromospheric magnetic fields, and detecting the presence of high temperature, low-emission measure plasma. We will discuss three sounding rocket instruments developed to make these measurements: the High-resolution Resolution Coronal Imager (Hi-C), the Chromospheric Lyman-Alpha Spectropolarimeter (CLASP), and the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS).
The Windowed Removable Partial Denture: A Treatment Option for Patients with Lone-Standing Teeth.
Jum'ah, Ahmad A; Haite, Terence; Nattress, Brian
2015-03-01
The decision as to whether to retain or extract a single remaining natural tooth prior to the provision of dentures can be a difficult one. If the tooth is left in situ, the development of an adequate peripheral seal around the denture is not possible thereby compromising the appliance' retention. If the tooth is extracted the possibility of gaining direct retention with the use of clasps or attachments is lost. This paper aims to illustrate the use of windowed removable partial denture design and review the literature relevant to this area. The use of such a design can enhance the retention of the appliance by encircling the lone standing tooth/teeth utilising an elastomeric permanent soft lining material.
Dynamics in the Chromosphere Imaged at Four Second Cadence
NASA Astrophysics Data System (ADS)
Schmit, D.; De Pontieu, B.
2017-12-01
In this work we present analysis of rapid intensity fluctuations that are observed in the chromosphere and transition region using the slit-jaw datasets of IRIS and CLASP. While chromospheric oscillations have been a topic of interest for 30 years, the instrumentation to image those dynamics at high-cadence has only recently been developed. We use filtergraph data from 1215A, 2800A, and 1400A to examine the occurrence rate and morphology of rapid intensity fluctuations in different magnetic environments. There are indications of rapidly propagating disturbances with phase speeds greater than 100 km/s in all passbands although the morphology of the features differs significantly between passbands. The relationship between intensity fluctuations, spicules, and waves is discussed.
Cpd-1 Null Mice Display a Subtle Neurological Phenotype
Kular, Rupinder K.; Gogliotti, Rocky G.; Opal, Puneet
2010-01-01
Background CPD1 (also known as ANP32-E) belongs to a family of evolutionarily conserved acidic proteins with leucine rich repeats implicated in a variety of cellular processes regulating gene expression, vesicular trafficking, intracellular signaling and apoptosis. Because of its spatiotemporal expression pattern, CPD1 has been proposed to play an important role in brain morphogenesis and synaptic development. Methodology/Principal Findings We have generated CPD1 knock-out mice that we have subsequently characterized. These mice are viable and fertile. However, they display a subtle neurological clasping phenotype and mild motor deficits. Conclusions/Significance CPD1 is not essential for normal development; however, it appears to play a role in the regulation of fine motor functions. The minimal phenotype suggests compensatory biological mechanisms. PMID:20844742
Strategy for Realizing High-Precision VUV Spectro-Polarimeter
NASA Astrophysics Data System (ADS)
Ishikawa, R.; Narukage, N.; Kubo, M.; Ishikawa, S.; Kano, R.; Tsuneta, S.
2014-12-01
Spectro-polarimetric observations in the vacuum ultraviolet (VUV) range are currently the only means to measure magnetic fields in the upper chromosphere and transition region of the solar atmosphere. The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) aims to measure linear polarization at the hydrogen Lyman- α line (121.6 nm). This measurement requires a polarization sensitivity better than 0.1 %, which is unprecedented in the VUV range. We here present a strategy with which to realize such high-precision spectro-polarimetry. This involves the optimization of instrument design, testing of optical components, extensive analyses of polarization errors, polarization calibration of the instrument, and calibration with onboard data. We expect that this strategy will aid the development of other advanced high-precision polarimeters in the UV as well as in other wavelength ranges.
RIDE vs. CLASP Comparison and Evaluation: Models and Parameters
2007-04-01
the model is declared "No Decision," indicating that neither QLRM nor LLRM provides a satisfactory fit. If p-value ( i 2j ) > p-value ( flj ), then our...evaluated at A = D = loo tD (7) UA/D(70,40) = 37.35 (8) UA/D(70,100) = 22.93 (9) OUA/D = 0 when evaluated at A = 70, D = 65.7 aD Note the number of...M U) U) C)U)f-~H W 0 U) co CQ CU)QC) W W 0 O40U) El)U tq D O U) U) E U) Z 04 X L X 4j c)c: o n n , f)cj" D ,m u)o mm o:zz .o tD o U) Uti)U) ’-4 r-4
Precision VUV Spectro-Polarimetry for Solar Chromospheric Magnetic Field Measurements
NASA Astrophysics Data System (ADS)
Ishikawa, R.; Bando, T.; Hara, H.; Ishikawa, S.; Kano, R.; Kubo, M.; Katsukawa, Y.; Kobiki, T.; Narukage, N.; Suematsu, Y.; Tsuneta, S.; Aoki, K.; Miyagawa, K.; Ichimoto, K.; Kobayashi, K.; Auchère, F.; Clasp Team
2014-10-01
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a VUV spectro-polarimeter optimized for measuring the linear polarization of the Lyman-α line (121.6 nm) to be launched in 2015 with NASA's sounding rocket (Ishikawa et al. 2011; Narukage et al. 2011; Kano et al. 2012; Kobayashi et al. 2012). With this experiment, we aim to (1) observe the scattering polarization in the Lyman-α line, (2) detect the Hanle effect, and (3) assess the magnetic fields in the upper chromosphere and transition region for the first time. The polarization measurement error consists of scale error δ a (error in amplitude of linear polarization), azimuth error Δφ (error in the direction of linear polarization), and spurious polarization ɛ (false linear polarization signals). The error ɛ should be suppressed below 0.1% in the Lyman-α core (121.567 nm ±0.02 nm), and 0.5% in the Lyman-α wing (121.567 nm ±0.05 nm), based on our scientific requirements shown in Table 2 of Kubo et al. (2014). From scientific justification, we adopt Δ φ<2° and δ a<10% as the instrument requirements. The spectro-polarimeter features a continuously rotating MgF2 waveplate (Ishikawa et al. 2013), a dual-beam spectrograph with a spherical grating working also as a beam splitter, and two polarization analyzers (Bridou et al. 2011), which are mounted at 90 degree from each other to measure two orthogonal polarization simultaneously. For the optical layout of the CLASP instrument, see Figure 3 in Kubo et al. (2014). Considering the continuous rotation of the half-waveplate, the modulation efficiency is 0.64 both for Stokes Q and U. All the raw data are returned and demodulation (successive addition or subtraction of images) is done on the ground. We control the CLASP polarization performance in the following three steps. First, we evaluate the throughput and polarization properties of each optical component in the Lyman-α line, using the Ultraviolet Synchrotron ORbital Radiation Facility (UVSOR) at the Institute for Molecular Science. The second step is polarization calibration of the spectro-polarimeter after alignment. Since the spurious polarization caused by the axisymmetric telescope is estimated to be negligibly small because of the symmetry (Ishikawa et al. 2014), we do not perform end-to-end polarization calibration. As the final step, before the scientific observation near the limb, we make a short observation at the Sun center and verify the polarization sensitivity, because the scattering polarization is expected to be close to zero at the Sun center due to symmetric geometry. In order to clarify whether we will be able to achieve the required polarization sensitivity and accuracy via these steps, we exercise polarization error budget, by investigating all the possible causes and their magnitudes of polarization errors, all of which are not necessarily verified by the polarization calibration. Based on these error budgets, we conclude that a polarization sensitivity of 0.1% in the line core, δ a<10% and Δ φ<2° can be achieved combined with the polarization calibration of the spectro-polarimeter and the onboard calibration at the Sun center(refer to Ishikawa et al. 2014, for the detail). We are currently conducting verification tests of the flight components and development of the UV light source for the polarization calibration. From 2014 spring, we will begin the integration, alignment, and calibration. We will update the error budgets throughout the course of these tests.
Multimedia manuscript. Heller myotomy and intraluminal fundoplication: a NOTES technique.
Perretta, Silvana; Dallemagne, Bernard; Allemann, Pierre; Alleman, Pierre; Marescaux, Jacques
2010-11-01
It is generally accepted that the most effective treatment of achalasia is a surgical myotomy. Nevertheless, if a myotomy alone is performed, reflux may occur in up to 30% of patients. The aim of this study was to explore a transoral incisionless stepwise approach to both esophageal Heller myotomy and fundoplication. The first step consisted of creating the esophageal myotomy. Under general anesthesia, with the pig supine, endoscopy was performed to assess the location of the esophagogastric junction (EGJ). The mucosa on the right posterolateral esophageal wall was cut with the needle-knife 15 cm above the lower esophageal sphincter (LES) and then dilated with blunt dissection to introduce the scope. A submucosal tunnel was created distally with CO(2) and blunt dissection. Once the gastroesophageal junction (GEJ) and the clasp fibers were identified, the muscular layer was cut. The scope was withdrawn into the lumen and the mucosal flap was sealed with endoscopic clips. The adequacy of the myotomy was evaluated using pre- and postoperative manometry and by comparing the EGJ distensibility before, during, and after the division of the esophageal muscular fibers using the functional lumen imaging probe, EndoFLIP®. The second step, consisted of building a transoral incisionless fundoplication 4 weeks postoperatively using the EsophyX™. Both Heller myotomy and endoscopic fundoplication were accomplished successfully with no injury to the esophageal mucosa. Postoperative manometry demonstrated a 50% loss in mean LES pressure (mean preoperative LES pressure = 22.2 mmHg; mean postoperative LES pressure = 10 mmHg, P < 0.005). The EndoFLIP® showed a preoperative minimal diameter of 6 mm with a cross-sectional area of 28 mm(2). Postoperatively, the junction was more compliant (minimal diameter = 15 mm; cross-sectional area = 177 mm(2)), with the main improvement in distensibility occurring when the clasps fibers were removed. A stepwise transoral incisionless approach to esophageal Heller myotomy and partial fundoplication is feasible and effective in the porcine model. A distensibility test such as the EndoFLIP® may provide better information on the opening and closing dynamics of the EGJ, rather than just relying on the sphincter tonic state as measured by manometry.
Kreilaus, Fabian; Spiro, Adena S; Hannan, Anthony J; Garner, Brett; Jenner, Andrew M
2015-01-01
Cholesterol has essential functions in neurological processes that require tight regulation of synthesis and metabolism. Perturbed cholesterol homeostasis has been demonstrated in Huntington's disease, however the exact role of these changes in disease pathogenesis is not fully understood. This study aimed to comprehensively examine changes in cholesterol biosynthetic precursors, metabolites and oxidation products in the striatum and cortex of the R6/1 transgenic mouse model of Huntington's disease. We also aimed to characterise the progression of the physical phenotype in these mice. GC-MS/MS was used to quantify a broad range of sterols in the striatum and cortex of R6/1 and wild type mice at 6, 12, 20, 24 and 28 weeks of age. Motor dysfunction was assessed over 28 weeks using the RotaRod and the hind-paw clasping tests. 24(S)-Hydroxycholesterol and 27-hydroxycholesterol were the major cholesterol metabolites that significantly changed in R6/1 mice. These changes were specifically localised to the striatum and were detected at the end stages of the disease. Cholesterol synthetic precursors (lathosterol and lanosterol) were significantly reduced in the cortex and striatum by 6 weeks of age, prior to the onset of motor dysfunction, as well as the cognitive and affective abnormalities previously reported. Elevated levels of desmosterol, a substrate of delta(24)-sterol reductase (DHCR24), were also detected in R6/1 mice at the end time-point. Female R6/1 mice exhibited a milder weight loss and hind paw clasping phenotype compared to male R6/1 mice, however, no difference in the brain sterol profile was detected between sexes. Several steps in cholesterol biosynthetic and metabolic pathways are differentially altered in the R6/1 mouse brain as the disease progresses and this is most severe in the striatum. This provides further insights into early molecular mediators of HD onset and disease progression and identifies candidate molecular targets for novel therapeutic approaches.
Valdeolivas, Sara; Sagredo, Onintza; Delgado, Mercedes; Pozo, Miguel A.; Fernández-Ruiz, Javier
2017-01-01
Several cannabinoids afforded neuroprotection in experimental models of Huntington’s disease (HD). We investigated whether a 1:1 combination of botanical extracts enriched in either ∆9-tetrahydrocannabinol (∆9-THC) or cannabidiol (CBD), which are the main constituents of the cannabis-based medicine Sativex®, is beneficial in R6/2 mice (a transgenic model of HD), as it was previously shown to have positive effects in neurotoxin-based models of HD. We recorded the progression of neurological deficits and the extent of striatal deterioration, using behavioral, in vivo imaging, and biochemical methods in R6/2 mice and their corresponding wild-type mice. The mice were daily treated, starting at 4 weeks after birth, with a Sativex-like combination of phytocannabinoids (equivalent to 3 mg/kg weight of pure CBD + ∆9-THC) or vehicle. R6/2 mice exhibited the characteristic deterioration in rotarod performance that initiated at 6 weeks and progressed up to 10 weeks, and elevated clasping behavior reflecting dystonia. Treatment with the Sativex-like combination of phytocannabinoids did not recover rotarod performance, but markedly attenuated clasping behavior. The in vivo positron emission tomography (PET) analysis of R6/2 animals at 10 weeks revealed a reduced metabolic activity in the basal ganglia, which was partially attenuated by treatment with the Sativex-like combination of phytocannabinoids. Proton nuclear magnetic resonance spectroscopy (H+-MRS) analysis of the ex vivo striatum of R6/2 mice at 12 weeks revealed changes in various prognostic markers reflecting events typically found in HD patients and animal models, such as energy failure, mitochondrial dysfunction, and excitotoxicity. Some of these changes (taurine/creatine, taurine/N-acetylaspartate, and N-acetylaspartate/choline ratios) were completely reversed by treatment with the Sativex-like combination of phytocannabinoids. A Sativex-like combination of phytocannabinoids administered to R6/2 mice at the onset of motor symptoms produced certain benefits on the progression of striatal deterioration in these mice, which supports the interest of this cannabinoid-based medicine for the treatment of disease progression in HD patients. PMID:28333097
Valdeolivas, Sara; Sagredo, Onintza; Delgado, Mercedes; Pozo, Miguel A; Fernández-Ruiz, Javier
2017-03-23
Several cannabinoids afforded neuroprotection in experimental models of Huntington's disease (HD). We investigated whether a 1:1 combination of botanical extracts enriched in either ∆⁸-tetrahydrocannabinol (∆⁸-THC) or cannabidiol (CBD), which are the main constituents of the cannabis-based medicine Sativex ® , is beneficial in R6/2 mice (a transgenic model of HD), as it was previously shown to have positive effects in neurotoxin-based models of HD. We recorded the progression of neurological deficits and the extent of striatal deterioration, using behavioral, in vivo imaging, and biochemical methods in R6/2 mice and their corresponding wild-type mice. The mice were daily treated, starting at 4 weeks after birth, with a Sativex-like combination of phytocannabinoids (equivalent to 3 mg/kg weight of pure CBD + ∆⁸-THC) or vehicle. R6/2 mice exhibited the characteristic deterioration in rotarod performance that initiated at 6 weeks and progressed up to 10 weeks, and elevated clasping behavior reflecting dystonia. Treatment with the Sativex-like combination of phytocannabinoids did not recover rotarod performance, but markedly attenuated clasping behavior. The in vivo positron emission tomography (PET) analysis of R6/2 animals at 10 weeks revealed a reduced metabolic activity in the basal ganglia, which was partially attenuated by treatment with the Sativex-like combination of phytocannabinoids. Proton nuclear magnetic resonance spectroscopy (H⁺-MRS) analysis of the ex vivo striatum of R6/2 mice at 12 weeks revealed changes in various prognostic markers reflecting events typically found in HD patients and animal models, such as energy failure, mitochondrial dysfunction, and excitotoxicity. Some of these changes (taurine/creatine, taurine/ N -acetylaspartate, and N -acetylaspartate/choline ratios) were completely reversed by treatment with the Sativex-like combination of phytocannabinoids. A Sativex-like combination of phytocannabinoids administered to R6/2 mice at the onset of motor symptoms produced certain benefits on the progression of striatal deterioration in these mice, which supports the interest of this cannabinoid-based medicine for the treatment of disease progression in HD patients.
Kordass, B; Ruge, S; Quooss, A; Hugger, A; Mundt, T
2014-01-01
Occlusal performance is a substantial determinant of the quality of dental prosthetic restorations. In the follow-up (SHIP 1) to the Study of Health in Pomerania (SHIP), a representative population of 3300 subjects was studied in the first exploratory evaluation of the occlusion of artificial teeth in the chewing center (first molar region) of partial dentures. A digital analysis of interocclusal records of habitual intercuspation position (ICP) was performed using the Greifswald Digital Analyzing System (GEDAS), a software package that identifies contact points as transparent areas. 562 subjects (280 men aged 61.7 ± 11.9 years and 282 women aged 60.7 ± 10.7 years) had maxillary removable partial dentures (RPDs), and 619 (271 men aged 65.0 ± 11.5 years and 348 women aged 62.4 ± 10.6 years) had mandibular RPDs. Most RPDs were retained with either attachment retainers (11.7% maxilla, 11.7% mandible), cast clasps (38.4% maxilla, 40.7% mandible), telescopes with double crowns (15.7% maxilla, 19.1% mandible), or wrought wire clasps (16.4% maxilla, 8.2% mandible). Some had a combination of different retention elements. The mean number of artificial teeth was 7.8 ± 2.9 in the maxilla and 7.5 ± 3.0 in the mandible. Only the artificial teeth (first molars) in mandibular partial dentures showed differences in the frequency of occlusal contacts between groups (chi-square test). Of these, telescopic crown-retained RPDs had the highest frequency of occlusal contacts (74.4% at tooth 36 and 77.1% at tooth 46), and wrought wire-retained RPDs had the lowest (48.4% at tooth 36 and 45.2% at tooth 46). The results for RPDs with a free-end saddle were comparable and analogous; contact frequencies for those with an interdental saddle did not differ significantly. Notably, the overall frequency of occlusal contacts was greater for tooth 46 (62.9%) than for tooth 36. In conclusion, when replacing teeth in the chewing center, particularly in the mandible, telescopic crown-retained RPDs offer a distinct advantage in terms of occlusal contacts and thus provide better occlusal stability.
[Operative applications of occupational therapy].
Saade, A
2010-01-01
Occupational therapy is the branch of rehabilitation whose main aim is to achieve maximum possible autonomy of the disabled person and the most complete integration into society, family and work. In subjects with motor disabilities following an occupational injury, the re-education programme includes a series of interventions aimed at progressive recovery of the ability to carry out work tasks compatible with the residual motor capacity of the worker. This article presents some examples related to the different stages making up the specific re-education programme: from the initial stages (with more purely kinesiotherapeutic techniques) directed at recovering movements and muscle strength, to the intermediate and final stages (more typically ergotherapeutic) directed first at the recovery of basic functions (clasping, pulling, pushing, lifting, lowering, carrying, etc.) and then, finally, retraining of work movements, with the introduction of compensatory methods and/or use of auxiliaries, when necessary.
The fatigue life of a cobalt-chromium alloy after laser welding.
Al-Bayaa, Nabil Jalal Ahmad; Clark, Robert K F; Juszczyk, Andrzej S; Radford, David R
2011-03-01
The aim of this study was to investigate the fatigue life of laser welded joints in a commercially available cast cobalt-chromium alloy. Twenty rod shaped specimens (40 mm x 1.5 mm) were cast and sand blasted. Ten specimens were used as controls and the remaining ten were sectioned and repaired using a pulsed Nd: YAG laser welder. All specimens were subjected to fatigue testing (30N - 2Hz) in a controlled environment. A statistically significant difference in median fatigue life was found between as-cast and laser welded specimens (p < 0.001). Consequently, the technique may not be appropriate for repairing cobalt chromium clasps on removable partial dentures. Scanning electron microscopy indicated the presence of cracks, pores and constriction of the outer surface in the welded specimens despite 70% penetration of the weld.
NASA Astrophysics Data System (ADS)
Potter, Wendell H.; Lynch, Robert B.
2013-01-01
The introductory physics course taken by biological science majors at UC Davis, Physics 7, was radically reformed 16 years ago in order to explicitly emphasize the development of scientific reasoning skills in all elements of the course. We have previously seen evidence of increased performance on the biological and physical science portions of the MCAT exam, in a rigorous systemic physiology course, and higher graduating GPAs for students who took Physics 7 rather than a traditionally taught introductory physics course. We report here on the increased performance by a group of biological-science majors in a general chemistry course who took the first quarter of Physics 7 prior to beginning the chemistry course sequence compared to a similar group who began taking physics after completing the first two quarters of general chemistry.
Agency elicits body-ownership: proprioceptive drift toward a synchronously acting external proxy.
Asai, Tomohisa
2016-05-01
Awareness of our own bodies (sense of body-ownership) and actions (sense of agency) is fundamental for self-consciousness. In the rubber hand illusion, watching a rubber hand being stroked synchronously as one's own unseen hand is also stroked causes the observer to attribute the rubber hand to their own body. The findings of the series of experiments reported here suggest that body-ownership, measured using proprioceptive drift, is elicited by the external acting proxy that drives the sense of agency. While participants clasped and unclasped their left hand for 60 s, they focused on video feedback on a monitor in front of them. Proprioceptive drift was observed only under the conditions, including synchronized conditions, where the sense of agency for the acting proxy occurred, suggesting an essential interaction between body-ownership and agency.
NASA Technical Reports Server (NTRS)
Ryder, Susan (Inventor)
1990-01-01
A body restraint system (30) allows the user's body (10) to be in the zero gravity neutral posture. The system (30) includes a waist restraint (32) in the form of a curved, padded unit (34) containing a retractable belt (36) coiled on a spring loaded capstan (38) with a buckle (40) extending from front (42) of the unit (34). A second belt (44) is fastened around the user's waist (16). A clasp (46) is configured to engage the buckle (40). The waist restraint (32) is positioned near foot restraints (52). The foot restraints (52) have foot platforms (59) with pads (60) of a suitable two part attaching material, such as the fasteners available from Minnesota Mining and Manufacturing Company under the trademark Scotchmate Duallock. A mating pad (62) of the material is provided on soles (64) of cotton net shoes (66).
Eddy covariance measurements of sea spray particles over the Atlantic Ocean
NASA Astrophysics Data System (ADS)
Norris, S.; Brooks, I.; de Leeuw, G.; Smith, M. H.; Moeman, M.; Lingard, J.
2007-09-01
Most estimates of sea spray aerosol source functions have used indirect means to infer the rate of production as a function of wind speed. Only recently has the technology become available to make high frequency measurements of aerosol concentration suitable for direct eddy correlation determination of the particle flux. This was accomplished in this study by combining a newly developed fast aerosol particle counter with an ultrasonic anemometer which allowed for eddy covariance measurements of size-segregated particle fluxes. The aerosol instrument is the Compact Lightweight Aerosol Spectrometer Probe (CLASP) - capable of measuring 8-channel size spectra for mean radii between 0.15 and 0.35 μm at 10 Hz. The first successful measurements were made during the WASFAB (Waves, Air Sea Fluxes, Aerosol and Bubbles) field campaign in October 2005 in Duck (NC, USA). The method and results are presented and comparisons are made with recent sea spray source functions from the literature.
Design of Standards and Labeling programs in Chile: Techno-Economic Analysis for Refrigerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Letschert, Virginie E.; McNeil, Michael A.; Pavon, Mariana
2013-05-01
Lawrence Berkeley National Laboratory is a global leader in the study of energy efficiency and its effective implementation through government policy. The Energy Analysis and Environmental Impacts Department of LBNL’s Environmental Energy Technologies Division provides technical assistance to help federal, stat e and local government agencies in the United States, and throughout the world, develop long-term strategies, policy, and programs to encourage energy efficiency in all sectors and industries. In the past, LBNL has assisted staff of various countries government agencies and their con tractors in providing methodologies to analyze cost-effectiveness of regulations and asses s overall national impacts ofmore » efficiency programs. The paper presents the work done in collaboration with the Ministry of Energy (MoE) in Chile and the Collaborative Labeling Appliance Standards Programs (CLASP) on designing a Minimum Energy Performance Standards (MEPS) and ext ending the current labeling program for refrigerators.« less
Mate-finding behaviour in Calanus marshallae Frost
Tsuda, A.
1998-01-01
Mate-finding behaviour by Calanus marshallae Frost, 1974, was observed and video recorded in a 1 m diameter kreisel. Newly moulted females signal to males by depositing vertical pheromone trails many tens of centimetres long. Males search for trails along primarily horizontal trajectories. The orthogonality of signal trace and search trail trajectory maximizes the chance of intersection. Males often initiate a dance of rapid, tight turns upon encountering a pheromone trail, then waggle down it (chase swimming) to the signalling female. She jumps away after initial contact, and the male follows. Many successive approach, bump and jump sequences follow, with mating eventually ensuing. The actual copulatory clasp and spermatophore transfer were not observed, although a few instances of brief attachment and tandem swimming were seen. Male dances occur at times when chase swimming does not follow, and the function of dances is not yet known.
An endoparasitoid Cretaceous fly and the evolution of parasitoidism.
Zhang, Qingqing; Zhang, Junfeng; Feng, Yitao; Zhang, Haichun; Wang, Bo
2016-02-01
Parasitoidism is a key innovation in insect evolution, and parasitoid insects, nowadays, play a significant role in structuring ecological communities. Despite their diversity and ecological impact, little is known about the early evolution and ecology of parasitoid insects, especially parasitoid true flies (Diptera). Here, we describe a bizarre fly, Zhenia xiai gen. et sp. nov., from Late Cretaceous Burmese amber (about 99 million years old) that represents the latest occurrence of the family Eremochaetidae. Z. xiai is an endoparasitoid insect as evidenced by a highly developed, hypodermic-like ovipositor formed by abdominal tergites VIII + IX that was used for injecting eggs into hosts and enlarged tridactylous claws supposedly for clasping hosts. Our results suggest that eremochaetids are among the earliest definite records of parasitoid insects. Our findings reveal an unexpected morphological specialization of flies and broaden our understanding of the evolution and diversity of ancient parasitoid insects.
Final crew portrait of STS-84 and Mir 23 crew in the Spacehab
1997-05-22
STS084-380-019 (15-24 May 1997) --- In the last minutes of joint activity between the STS-84 and Russian Space Agency (RSA) Mir-23 crews, ten astronauts and cosmonauts pose for an in-space portrait in the Space Shuttle Atlantis Spacehab Double Module (DM). For orientation purposes, photo should be held with clasped hands of Aleksandr I. Lazutkin (wearing Mir-23 suit) just below center. The flight engineer is flanked by similarly attired crew mates Vasili Tsibliyev, Mir-23 commander, on the left, and C. Michael Foale, cosmonaut guest researcher, on the right. The STS-84 crew members are, clockwise from the left, Jerry M. Linenger, mission specialist; Eileen M. Collins, pilot; Edward T. Lu, mission specialist; Jean-Fran?ois Clervoy, payload commander; Elena V. Kondakova and Carlos I. Noriega, both mission specialists, along with Charles J. Precourt, mission commander.
STS-92 M.S. Michael Lopez-Alegria suits up for launch
NASA Technical Reports Server (NTRS)
2000-01-01
During suitup in the Operations and Checkout Building, STS-92 Mission Specialist Michael E. Lopez-Alegria smiles and clasps his hands in anticipation of a second launch attempt. He and the rest of the crew will be heading out to the Astrovan for the ride to Launch Pad 39A. During the 11-day mission to the International Space Station, four extravehicular activities (EVAs), or spacewalks, are planned for construction. The payload includes the Integrated Truss Structure Z-1 and the third Pressurized Mating Adapter. The Z-1 truss is the first of 10 that will become the backbone of the Space Station, eventually stretching the length of a football field. PMA-3 will provide a Shuttle docking port for solar array installation on the sixth Station flight and Lab installation on the seventh Station flight. Launch is scheduled for 7:17 p.m. EDT. Landing is expected Oct. 22 at 2:10 p.m. EDT.
Mapping pathological phenotypes in a mouse model of CDKL5 disorder.
Amendola, Elena; Zhan, Yang; Mattucci, Camilla; Castroflorio, Enrico; Calcagno, Eleonora; Fuchs, Claudia; Lonetti, Giuseppina; Silingardi, Davide; Vyssotski, Alexei L; Farley, Dominika; Ciani, Elisabetta; Pizzorusso, Tommaso; Giustetto, Maurizio; Gross, Cornelius T
2014-01-01
Mutations in cyclin-dependent kinase-like 5 (CDKL5) cause early-onset epileptic encephalopathy, a neurodevelopmental disorder with similarities to Rett Syndrome. Here we describe the physiological, molecular, and behavioral phenotyping of a Cdkl5 conditional knockout mouse model of CDKL5 disorder. Behavioral analysis of constitutive Cdkl5 knockout mice revealed key features of the human disorder, including limb clasping, hypoactivity, and abnormal eye tracking. Anatomical, physiological, and molecular analysis of the knockout uncovered potential pathological substrates of the disorder, including reduced dendritic arborization of cortical neurons, abnormal electroencephalograph (EEG) responses to convulsant treatment, decreased visual evoked responses (VEPs), and alterations in the Akt/rpS6 signaling pathway. Selective knockout of Cdkl5 in excitatory and inhibitory forebrain neurons allowed us to map the behavioral features of the disorder to separable cell-types. These findings identify physiological and molecular deficits in specific forebrain neuron populations as possible pathological substrates in CDKL5 disorder.
Struvite formation and the fouling propensity of different materials.
Doyle, J D; Oldring, K; Churchley, J; Parsons, S A
2002-09-01
Struvite (MgNH4PO4 x 6H2O) fouling was investigated to identify the impact supersaturation and material had on scaling rates. Tests were undertaken at three supersaturation ratios and with three different materials: stainless steel, teflon and acrylic. Impellers consisting of a clasp unit and two corrosion coupons that could be attached were used to mix centrate liquor and precipitation was initiated by the change in pH caused by degassing. Increasing the supersaturation ratio from 1.7 to 5.3 led to a doubling in the scaling rate of stainless-steel coupons. Experiments with acrylic and teflon coupons showed the influence of surface roughness upon scaling propensity. Coarsely roughened coupons following 40 h of mixing had a mass of 413 mg of struvite attached compared to smooth coupons that had a mass of 240 mg attached. Material did have an influence upon struvite fouling but this influence diminished with increasing surface roughness.
An endoparasitoid Cretaceous fly and the evolution of parasitoidism
NASA Astrophysics Data System (ADS)
Zhang, Qingqing; Zhang, Junfeng; Feng, Yitao; Zhang, Haichun; Wang, Bo
2016-02-01
Parasitoidism is a key innovation in insect evolution, and parasitoid insects, nowadays, play a significant role in structuring ecological communities. Despite their diversity and ecological impact, little is known about the early evolution and ecology of parasitoid insects, especially parasitoid true flies (Diptera). Here, we describe a bizarre fly, Zhenia xiai gen. et sp. nov., from Late Cretaceous Burmese amber (about 99 million years old) that represents the latest occurrence of the family Eremochaetidae. Z. xiai is an endoparasitoid insect as evidenced by a highly developed, hypodermic-like ovipositor formed by abdominal tergites VIII + IX that was used for injecting eggs into hosts and enlarged tridactylous claws supposedly for clasping hosts. Our results suggest that eremochaetids are among the earliest definite records of parasitoid insects. Our findings reveal an unexpected morphological specialization of flies and broaden our understanding of the evolution and diversity of ancient parasitoid insects.
Birefringence of magnesium fluoride in the vacuum ultraviolet and application to a half-waveplate.
Ishikawa, Ryohko; Kano, Ryouhei; Bando, Takamasa; Suematsu, Yoshinori; Ishikawa, Shin-nosuke; Kubo, Masahito; Narukage, Noriyuki; Hara, Hirohisa; Tsuneta, Saku; Watanabe, Hiroko; Ichimoto, Kiyoshi; Aoki, Kunichika; Miyagawa, Kenta
2013-12-01
Spectro-polarimeteric observations in the vacuum-ultraviolet (VUV) region are expected to be developed as a new astrophysics diagnostic tool for investigating space plasmas with temperatures of >10(4) K. Precise measurements of the difference in the extraordinary and ordinary refractive indices are required for developing accurate polarimeters, but reliable information on the birefringence in the VUV range is difficult to obtain. We have measured the birefringence of magnesium fluoride (MgF2) with an accuracy of better than ±4×10(-5) around the hydrogen Lyman-α line (121.57 nm). We show that MgF2 can be applied practically as a half-waveplate for the chromospheric Lyman-alpha spectro-polarimeter (CLASP) sounding rocket experiment and that the developed measurement method can be easily applied to other VUV birefringent materials at other wavelengths.
Michalsik, Lars Bojsen; Madsen, Klavs; Aagaard, Per
2015-02-01
Modern team handball match-play imposes substantial physical and technical demands on elite players. However, only limited knowledge seems to exist about the specific working requirements in elite team handball. Thus, the purpose of this study was to examine the physical demands imposed on male elite team handball players in relation to playing position and body anthropometry. Based on continuous video recording of individual players during elite team handball match-play (62 tournament games, ∼4 players per game), computerized technical match analysis was performed in male elite team handball players along with anthropometric measurements over a 6 season time span. Technical match activities were distributed in 6 major types of playing actions (shots, breakthroughs, fast breaks, tackles, technical errors, and defense errors) and further divided into various subcategories (e.g., hard or light tackles, type of shot, claspings, screenings, and blockings). Players showed 36.9 ± 13.1 (group mean ± SD) high-intense technical playing actions per match with a mean total effective playing time of 53.85 ± 5.87 minutes. In offense, each player performed 6.0 ± 5.2 fast breaks, received 34.5 ± 21.3 tackles in total, and performed in defense 3.7 ± 3.5 blockings, 3.9 ± 3.0 claspings, and 5.8 ± 3.6 hard tackles. Wing players (84.5 ± 5.8 kg, 184.9 ± 5.7 cm) were less heavy and smaller (p < 0.001) than backcourt players (94.7 ± 7.1 kg, 191.9 ± 5.4 cm) and pivots (99.4 ± 6.2 kg, 194.8 ± 3.6 cm). In conclusion, modern male elite team handball match-play is characterized by a high number of short-term, high-intense intermittent technical playing actions. Indications of technical fatigue were observed. Physical demands differed between playing positions with wing players performing more fast breaks and less physical confrontations with opponent players than backcourt players and pivots. Body anthropometry seemed to have an important influence on playing performance because it is highly related to playing positions. The present observations suggest that male elite team handball players should implement more position-specific training regimens, while also focusing on anaerobic training and strength training.
Toward an Ultralow-Power Onboard Processor for Tongue Drive System
Viseh, Sina; Ghovanloo, Maysam; Mohsenin, Tinoosh
2015-01-01
The Tongue Drive System (TDS) is a new unobtrusive, wireless, and wearable assistive device that allows for real-time tracking of the voluntary tongue motion in the oral space for communication, control, and navigation applications. The latest TDS prototype appears as a wireless headphone and has been tested in human subject trials. However, the robustness of the external TDS (eTDS) in real-life outdoor conditions may not meet safety regulations because of the limited mechanical stability of the headset. The intraoral TDS (iTDS), which is in the shape of a dental retainer, firmly clasps to the upper teeth and resists sensor misplacement. However, the iTDS has more restrictions on its dimensions, limiting the battery size and consequently requiring a considerable reduction in its power consumption to operate over an extended period of two days on a single charge. In this brief, we propose an ultralow-power local processor for the TDS that performs all signal processing on the transmitter side, following the sensors. Assuming the TDS user on average issuing one command/s, implementing the computational engine reduces the data volume that needs to be wirelessly transmitted to a PC or smartphone by a factor of 1500×, from 12 kb/s to ~8 b/s. The proposed design is implemented on an ultralow-power IGLOO nano field-programmable gate array (FPGA) and is tested on AGLN250 prototype board. According to our post-place-and-route results, implementing the engine on the FPGA significantly drops the required data transmission, while an application-specific integrated circuit (ASIC) implementation in a 65-nm CMOS results in a 15× power saving compared to the FPGA solution and occupies a 0.02-mm2 footprint. As a result, the power consumption and size of the iTDS will be significantly reduced through the use of a much smaller rechargeable battery. Moreover, the system can operate longer following every recharge, improving the iTDS usability. PMID:26185489
Toward an Ultralow-Power Onboard Processor for Tongue Drive System.
Viseh, Sina; Ghovanloo, Maysam; Mohsenin, Tinoosh
2015-02-01
The Tongue Drive System (TDS) is a new unobtrusive, wireless, and wearable assistive device that allows for real-time tracking of the voluntary tongue motion in the oral space for communication, control, and navigation applications. The latest TDS prototype appears as a wireless headphone and has been tested in human subject trials. However, the robustness of the external TDS (eTDS) in real-life outdoor conditions may not meet safety regulations because of the limited mechanical stability of the headset. The intraoral TDS (iTDS), which is in the shape of a dental retainer, firmly clasps to the upper teeth and resists sensor misplacement. However, the iTDS has more restrictions on its dimensions, limiting the battery size and consequently requiring a considerable reduction in its power consumption to operate over an extended period of two days on a single charge. In this brief, we propose an ultralow-power local processor for the TDS that performs all signal processing on the transmitter side, following the sensors. Assuming the TDS user on average issuing one command/s, implementing the computational engine reduces the data volume that needs to be wirelessly transmitted to a PC or smartphone by a factor of 1500×, from 12 kb/s to ~8 b/s. The proposed design is implemented on an ultralow-power IGLOO nano field-programmable gate array (FPGA) and is tested on AGLN250 prototype board. According to our post-place-and-route results, implementing the engine on the FPGA significantly drops the required data transmission, while an application-specific integrated circuit (ASIC) implementation in a 65-nm CMOS results in a 15× power saving compared to the FPGA solution and occupies a 0.02-mm 2 footprint. As a result, the power consumption and size of the iTDS will be significantly reduced through the use of a much smaller rechargeable battery. Moreover, the system can operate longer following every recharge, improving the iTDS usability.
Eddy covariance measurements of sea spray particles over the Atlantic Ocean
NASA Astrophysics Data System (ADS)
Norris, S. J.; Brooks, I. M.; de Leeuw, G.; Smith, M. H.; Moerman, M.; Lingard, J. J. N.
2008-02-01
Most estimates of sea spray aerosol source functions have used indirect means to infer the rate of production as a function of wind speed. Only recently has the technology become available to make high frequency measurements of aerosol spectra suitable for direct eddy correlation determination of the sea spray particle flux. This was accomplished in this study by combining a newly developed fast aerosol particle counter with an ultrasonic anemometer which allowed for eddy covariance measurements of size-segregated particle fluxes. The aerosol instrument is the Compact Lightweight Aerosol Spectrometer Probe (CLASP) - capable of measuring 8-channel size spectra for mean radii between 0.15 and 3.5 µm at 10 Hz. The first successful measurements were made during the Waves, Air Sea Fluxes, Aerosol and Bubbles (WASFAB) field campaign in October 2005 in Duck (NC, USA). The method and initial results are presented and comparisons are made with recent sea spray source functions from the literature.
Defining NADH-Driven Allostery Regulating Apoptosis-Inducing Factor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brosey, Chris A.; Ho, Chris; Long, Winnie Z.
Apoptosis-inducing factor (AIF) is critical for mitochondrial respiratory complex biogenesis and for mediating necroptotic parthanatos; these functions are seemingly regulated by enigmatic allosteric switching driven by NADH charge-transfer complex (CTC) formation. In this paper, we define molecular pathways linking AIF's active site to allosteric switching regions by characterizing dimer-permissive mutants using small-angle X-ray scattering (SAXS) and crystallography and by probing AIF-CTC communication networks using molecular dynamics simulations. Collective results identify two pathways propagating allostery from the CTC active site: (1) active-site H454 links to S480 of AIF's central β-strand to modulate a hydrophobic border at the dimerization interface, and (2)more » an interaction network links AIF's FAD cofactor, central β-strand, and Cβ-clasp whereby R529 reorientation initiates C-loop release during CTC formation. Finally, this knowledge of AIF allostery and its flavoswitch mechanism provides a foundation for biologically understanding and biomedically controlling its participation in mitochondrial homeostasis and cell death.« less
Nagakura, Manamu; Tanimoto, Yasuhiro; Nishiyama, Norihiro
2017-07-26
The use of non-metal clasp denture (NMCD) materials may seriously affect the remaining tissues because of the low rigidity of NMCD materials such as polyamides. The purpose of this study was to develop a high-rigidity glass fiber-reinforced thermoplastic (GFRTP) composed of E-glass fiber and polyamide-6 for NMCDs using an injection molding. The reinforcing effects of fiber on the flexural properties of GFRTPs were investigated using glass fiber content ranging from 0 to 50 mass%. Three-point bending tests indicated that the flexural strength and elastic modulus of a GFRTP with a fiber content of 50 mass% were 5.4 and 4.7 times higher than those of unreinforced polyamide-6, respectively. The result showed that the physical characteristics of GFRTPs were greatly improved by increasing the fiber content, and the beneficial effects of fiber reinforcement were evident. The findings suggest that the injection-molded GFRTPs are adaptable to NMCDs because of their excellent mechanical properties.
The Piriform Cortex and Human Focal Epilepsy
Vaughan, David N.; Jackson, Graeme D.
2014-01-01
It is surprising that the piriform cortex, when compared to the hippocampus, has been given relatively little significance in human epilepsy. Like the hippocampus, it has a phylogenetically preserved three-layered cortex that is vulnerable to excitotoxic injury, has broad connections to both limbic and cortical areas, and is highly epileptogenic – being critical to the kindling process. The well-known phenomenon of early olfactory auras in temporal lobe epilepsy highlights its clinical relevance in human beings. Perhaps because it is anatomically indistinct and difficult to approach surgically, as it clasps the middle cerebral artery, it has, until now, been understandably neglected. In this review, we emphasize how its unique anatomical and functional properties, as primary olfactory cortex, predispose it to involvement in focal epilepsy. From recent convergent findings in human neuroimaging, clinical epileptology, and experimental animal models, we make the case that the piriform cortex is likely to play a facilitating and amplifying role in human focal epileptogenesis, and may influence progression to epileptic intractability. PMID:25538678
Defining NADH-Driven Allostery Regulating Apoptosis-Inducing Factor
Brosey, Chris A.; Ho, Chris; Long, Winnie Z.; ...
2016-11-03
Apoptosis-inducing factor (AIF) is critical for mitochondrial respiratory complex biogenesis and for mediating necroptotic parthanatos; these functions are seemingly regulated by enigmatic allosteric switching driven by NADH charge-transfer complex (CTC) formation. In this paper, we define molecular pathways linking AIF's active site to allosteric switching regions by characterizing dimer-permissive mutants using small-angle X-ray scattering (SAXS) and crystallography and by probing AIF-CTC communication networks using molecular dynamics simulations. Collective results identify two pathways propagating allostery from the CTC active site: (1) active-site H454 links to S480 of AIF's central β-strand to modulate a hydrophobic border at the dimerization interface, and (2)more » an interaction network links AIF's FAD cofactor, central β-strand, and Cβ-clasp whereby R529 reorientation initiates C-loop release during CTC formation. Finally, this knowledge of AIF allostery and its flavoswitch mechanism provides a foundation for biologically understanding and biomedically controlling its participation in mitochondrial homeostasis and cell death.« less
Vacuum ultraviolet spectropolarimeter design for precise polarization measurements.
Narukage, Noriyuki; Auchère, Frédéric; Ishikawa, Ryohko; Kano, Ryouhei; Tsuneta, Saku; Winebarger, Amy R; Kobayashi, Ken
2015-03-10
Precise polarization measurements in the vacuum ultraviolet (VUV) region provide a new means for inferring weak magnetic fields in the upper atmosphere of the Sun and stars. We propose a VUV spectropolarimeter design ideally suited for this purpose. This design is proposed and adopted for the NASA-JAXA chromospheric lyman-alpha spectropolarimeter (CLASP), which will record the linear polarization (Stokes Q and U) of the hydrogen Lyman-α line (121.567 nm) profile. The expected degree of polarization is on the order of 0.1%. Our spectropolarimeter has two optically symmetric channels to simultaneously measure orthogonal linear polarization states with a single concave diffraction grating that serves both as the spectral dispersion element and beam splitter. This design has a minimal number of reflective components with a high VUV throughput. Consequently, these design features allow us to minimize the polarization errors caused by possible time variation of the VUV flux during the polarization modulation and by statistical photon noise.
A mitotic SKAP isoform regulates spindle positioning at astral microtubule plus ends
Kern, David M.; Nicholls, Peter K.; Page, David C.
2016-01-01
The Astrin/SKAP complex plays important roles in mitotic chromosome alignment and centrosome integrity, but previous work found conflicting results for SKAP function. Here, we demonstrate that SKAP is expressed as two distinct isoforms in mammals: a longer, testis-specific isoform that was used for the previous studies in mitotic cells and a novel, shorter mitotic isoform. Unlike the long isoform, short SKAP rescues SKAP depletion in mitosis and displays robust microtubule plus-end tracking, including localization to astral microtubules. Eliminating SKAP microtubule binding results in severe chromosome segregation defects. In contrast, SKAP mutants specifically defective for plus-end tracking facilitate proper chromosome segregation but display spindle positioning defects. Cells lacking SKAP plus-end tracking have reduced Clasp1 localization at microtubule plus ends and display increased lateral microtubule contacts with the cell cortex, which we propose results in unbalanced dynein-dependent cortical pulling forces. Our work reveals an unappreciated role for the Astrin/SKAP complex as an astral microtubule mediator of mitotic spindle positioning. PMID:27138257
Mapping Pathological Phenotypes in a Mouse Model of CDKL5 Disorder
Amendola, Elena; Zhan, Yang; Mattucci, Camilla; Castroflorio, Enrico; Calcagno, Eleonora; Fuchs, Claudia; Lonetti, Giuseppina; Silingardi, Davide; Vyssotski, Alexei L.; Farley, Dominika; Ciani, Elisabetta; Pizzorusso, Tommaso; Giustetto, Maurizio; Gross, Cornelius T.
2014-01-01
Mutations in cyclin-dependent kinase-like 5 (CDKL5) cause early-onset epileptic encephalopathy, a neurodevelopmental disorder with similarities to Rett Syndrome. Here we describe the physiological, molecular, and behavioral phenotyping of a Cdkl5 conditional knockout mouse model of CDKL5 disorder. Behavioral analysis of constitutive Cdkl5 knockout mice revealed key features of the human disorder, including limb clasping, hypoactivity, and abnormal eye tracking. Anatomical, physiological, and molecular analysis of the knockout uncovered potential pathological substrates of the disorder, including reduced dendritic arborization of cortical neurons, abnormal electroencephalograph (EEG) responses to convulsant treatment, decreased visual evoked responses (VEPs), and alterations in the Akt/rpS6 signaling pathway. Selective knockout of Cdkl5 in excitatory and inhibitory forebrain neurons allowed us to map the behavioral features of the disorder to separable cell-types. These findings identify physiological and molecular deficits in specific forebrain neuron populations as possible pathological substrates in CDKL5 disorder. PMID:24838000
Protein design on computers. Five new proteins: Shpilka, Grendel, Fingerclasp, Leather, and Aida.
Sander, C; Vriend, G; Bazan, F; Horovitz, A; Nakamura, H; Ribas, L; Finkelstein, A V; Lockhart, A; Merkl, R; Perry, L J
1992-02-01
What is the current state of the art in protein design? This question was approached in a recent two-week protein design workshop sponsored by EMBO and held at the EMBL in Heidelberg. The goals were to test available design tools and to explore new design strategies. Five novel proteins were designed: Shpilka, a sandwich of two four-stranded beta-sheets, a scaffold on which to explore variations in loop topology; Grendel, a four-helical membrane anchor, ready for fusion to water-soluble functional domains; Finger-clasp, a dimer of interdigitating beta-beta-alpha units, the simplest variant of the "handshake" structural class; Aida, an antibody binding surface intended to be specific for flavodoxin; Leather--a minimal NAD binding domain, extracted from a larger protein. Each design is available as a set of three-dimensional coordinates, the corresponding amino acid sequence and a set of analytical results. The designs are placed in the public domain for scrutiny, improvement, and possible experimental verification.
Airborne fibre and asbestos concentrations in system built schools
NASA Astrophysics Data System (ADS)
Burdett, Garry; Cottrell, Steve; Taylor, Catherine
2009-02-01
This paper summarises the airborne fibre concentration data measured in system built schools that contained asbestos insulation board (AIB) enclosed in the support columns by a protective steel casing. The particular focus of this work was the CLASP (Consortium of Local Authorities Special Programme) system buildings. A variety of air monitoring tests were carried out to assess the potential for fibres to be released into the classroom. A peak release testing protocol was adopted that involved static sampling, while simulating direct impact disturbances to selected columns. This was carried out before remediation, after sealing gaps and holes in and around the casing visible in the room (i.e. below ceiling level) and additionally round the tops of the columns, which extended into the suspended ceiling void. Simulated and actual measurements of worker exposures were also undertaken, while sealing columns, carrying out cleaning and maintenance work in the ceiling voids. Routine analysis of these air samples was carried out by phase contrast microscopy (PCM) with a limited amount of analytical transmission electron microscopy (TEM) analysis to confirm whether the fibres visible by PCM were asbestos or non-asbestos. The PCM fibre concentrations data from the peak release tests showed that while direct releases of fibres to the room air can occur from gaps and holes in and around the column casings, sealing is an effective way of minimising releases to below the limit of quantification (0.01 f/ml) of the PCM method for some 95% of the tests carried out. Sealing with silicone filler and taping any gaps and seams visible on the column casing in the room, also gave concentrations below the limit of quantification (LOQ) of the PCM method for 95% of the tests carried out. The data available did not show any significant difference between the PCM fibre concentrations in the room air for columns that had or had not been sealed in the ceiling void, as well as in the room. Occupant exposures during normal classroom teaching activities in areas that had undergone remediation were also monitored with much greater use of TEM analysis to determine the asbestos fibre concentration. No asbestos fibres were found in the TEM analysis of samples of classroom air from seven schools, after remediation had taken place. Occupant exposures in one school and one office building have been monitored before remediation and only one asbestos fibre was found in each set of samples analysed. The average monitored occupant exposures to asbestos in CLASP buildings was <0.00005 f/ml, an order of magnitude lower than previous measurements in UK buildings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Letschert, Virginie E.; McNeil, Michael A.; Leiva Ibanez, Francisco Humberto
2011-06-01
Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrencemore » Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The Life-Cycle Cost (LCC) calculation examines costs and benefits from the perspective of the individual household; and (2) The National Perspective projects the total national costs and benefits including both financial benefits, and energy savings and environmental benefits. The national perspective calculations are called the National Energy Savings (NES) and the Net Present Value (NPV) calculations. PAMS also calculate total emission mitigation and avoided generation capacity. This paper describes the data and methodology used in PAMS and presents the results of the proposed phase out of incandescent bulbs in Chile.« less
Michalsik, Lars B; Aagaard, Per; Madsen, Klavs
2015-04-01
To determine the physical demands placed on female elite team handball (TH) players in relation to playing position and body anthropometry, female elite TH primarily field players were monitored during match-play using video recording and subsequent computerized technical match analysis during 5 regular tournament match seasons. Technical match activities were distributed in 6 major types of playing actions (shots, breakthroughs, fast breaks, technical errors, defensive errors, and tackles) and further divided into various subcategories (e.g., type of shot, hard or light tackles, claspings, screenings, and blockings). Furthermore, anthropometric measurements were performed. Each player had 28.3 ± 11.0 (group means ± SD) high-intense playing actions per match with a total effective playing time of 50.70 ± 5.83 minutes. On average, each player made 2.8 ± 2.6 fast breaks, gave 7.9 ± 14.4 screenings, received 14.6 ± 9.2 tackles in total, and performed 7.7 ± 3.7 shots while in offense, along with 3.5 ± 3.8 blockings, 1.9 ± 2.7 claspings, and 6.2 ± 3.8 hard tackles in defense. Mean body height, body mass, and age in the Danish Premier Female Team Handball League were 175.4 ± 6.1 cm, 69.5 ± 6.5 kg, and 25.4 ± 3.7 years, respectively. Wing players were lighter (63.5 ± 4.8 kg, p < 0.001) and smaller (169.3 ± 4.9 cm, p < 0.001) than backcourt players (BP) (70.6 ± 5.3 kg, 177.0 ± 5.4 cm) and pivots (PV) (72.5 ± 4.9 kg, 177.7 ± 4.9 cm). In conclusion, the present match observations revealed that female elite TH players during competitive games intermittently perform a high number of short-term, high-intense technical playing actions making modern female elite TH a physically demanding team sport. No sign of technical fatigue were observed, since the amount of intense technical playing actions remained unchanged in the second half. Marked positional differences in the physical demands were demonstrated, with wing players performing more fast breaks and less physical confrontations than BP and PV. Body anthropometry differed substantially between different playing positions. Consequently, this should lead to an increase in physical training in modern female elite TH directed at specific positions and individual physical capacity.
NASA Astrophysics Data System (ADS)
Yamada, Toru; Ohashi, Mitsuo; Umeyama, Shinji
2015-12-01
Functional near-infrared spectroscopy (fNIRS) can non-invasively detect hemodynamic changes associated with cerebral neural activation in human subjects. However, its signal is often affected by changes in the optical characteristics of tissues in the head other than brain. To conduct fNIRS measurements precisely and efficiently, the extraction and realtime monitoring of the cerebral functional component is crucial. We previously developed methods for extracting the cerebral functional component—the multidistance optode arrangement (MD) method and the hemodynamic modality separation (HMS) method. In this study, we implemented these methods in a software used with the fNIRS system OEG- 17APD (Spectratech, Japan), and realized a real-time display of the extracted results. When using this system for human subject experiments, the baselines obtained with the MD and HMS methods were highly stabilized, whereas originally, the fNIRS signal fluctuated significantly when the subject moved. Through a functional experiment with repetitive single-sided hand clasping tasks, the extracted signals showed distinctively higher reproducibility than that obtained in the conventional measurements.
Rincon, Sergio A.; Lamson, Adam; Blackwell, Robert; Syrovatkina, Viktoriya; Fraisier, Vincent; Paoletti, Anne; Betterton, Meredith D.; Tran, Phong T.
2017-01-01
Bipolar spindle assembly requires a balance of forces where kinesin-5 produces outward pushing forces to antagonize the inward pulling forces from kinesin-14 or dynein. Accordingly, Kinesin-5 inactivation results in force imbalance leading to monopolar spindle and chromosome segregation failure. In fission yeast, force balance is restored when both kinesin-5 Cut7 and kinesin-14 Pkl1 are deleted, restoring spindle bipolarity. Here we show that the cut7Δpkl1Δ spindle is fully competent for chromosome segregation independently of motor activity, except for kinesin-6 Klp9, which is required for anaphase spindle elongation. We demonstrate that cut7Δpkl1Δ spindle bipolarity requires the microtubule antiparallel bundler PRC1/Ase1 to recruit CLASP/Cls1 to stabilize microtubules. Brownian dynamics-kinetic Monte Carlo simulations show that Ase1 and Cls1 activity are sufficient for initial bipolar spindle formation. We conclude that pushing forces generated by microtubule polymerization are sufficient to promote spindle pole separation and the assembly of bipolar spindle in the absence of molecular motors. PMID:28513584
Stiffness and force in activated frog skeletal muscle fibers.
Cecchi, G.; Griffiths, P. J.; Taylor, S.
1986-01-01
Single fibers, isolated intact from frog skeletal muscles, were held firmly very near to each end by stiff metal clasps fastened to the tendons. The fibers were then placed horizontally between two steel hooks inserted in eyelets of the tendon clasps. One hook was attached to a capacitance gauge force transducer (resonance frequency up to approximately 50 kHz) and the other was attached to a moving-coil length changer. This allowed us to impose small, rapid releases (complete in less than 0.15 ms) and high frequency oscillations (up to 13 kHz) to one end of a resting or contracting fiber and measure the consequences at the other end with fast time resolution at 4 to 6 degrees C. The stiffness of short fibers (1.8-2.6 mm) was determined directly from the ratio of force to length variations produced by the length changer. The resonance frequency of short fibers was so high (approximately 40 kHz) that intrinsic oscillations were not detectably excited. The stiffness of long fibers, on the other hand, was calculated from measurement of the mechanical resonance frequency of a fiber. Using both short and long fibers, we measured the sinusoids of force at one end of a contracting fiber that were produced by relatively small sinusoidal length changes at the other end. The amplitudes of the sinusoidal length changes were small compared with the size of step changes that produce nonlinear force-extension relations. The sinusoids of force from long fibers changed amplitude and shifted phase with changes in oscillation frequency in a manner expected of a transmission line composed of mass, compliance, and viscosity, similar to that modelled by (Ford, L. E., A. F. Huxley, and R. M. Simmons, 1981, J. Physiol. (Lond.), 311:219-249). A rapid release during the plateau of tetanic tension in short fibers caused a fall in force and stiffness, a relative change in stiffness that putatively was much smaller than that of force. Our results are, for the most part, consistent with the cross-bridge model of force generation proposed by Huxley, A. F., and R. M. Simmons (1971, Nature (Lond.), 213:533-538). However, stiffness in short fibers developed markedly faster than force during the tetanus rise. Thus our findings show the presence of one or more noteworthy cross-bridge states at the onset and during the rise of active tension towards a plateau in that attachment apparently is followed by a relatively long delay before force generation occurs. A set of equations is given in the Appendix that describes the frequency dependence of the applied sinusoid and its response. This model predicts that frequency dependent changes can be used as a measure of a change in stiffness. PMID:3955178
Forming Facial Expressions Influences Assessment of Others' Dominance but Not Trustworthiness.
Ueda, Yoshiyuki; Nagoya, Kie; Yoshikawa, Sakiko; Nomura, Michio
2017-01-01
Forming specific facial expressions influences emotions and perception. Bearing this in mind, studies should be reconsidered in which observers expressing neutral emotions inferred personal traits from the facial expressions of others. In the present study, participants were asked to make happy, neutral, and disgusted facial expressions: for "happy," they held a wooden chopstick in their molars to form a smile; for "neutral," they clasped the chopstick between their lips, making no expression; for "disgusted," they put the chopstick between their upper lip and nose and knit their brows in a scowl. However, they were not asked to intentionally change their emotional state. Observers judged happy expression images as more trustworthy, competent, warm, friendly, and distinctive than disgusted expression images, regardless of the observers' own facial expression. Observers judged disgusted expression images as more dominant than happy expression images. However, observers expressing disgust overestimated dominance in observed disgusted expression images and underestimated dominance in happy expression images. In contrast, observers with happy facial forms attenuated dominance for disgusted expression images. These results suggest that dominance inferred from facial expressions is unstable and influenced by not only the observed facial expression, but also the observers' own physiological states.
Sidiq, Mohsin; Yousuf, Asif; Bhat, Manohar; Sharma, Rajesh; Bhargava, Neha; Ganta, Shravani
2015-01-01
The aim of this case study was to report a potentially convenient approach instead of a conventional orthodontic procedure for correcting severe rotation of anterior tooth of an 11-year-old Indian boy, with a mixed dentition class I malocclusion. The child reported seeking treatment for severely rotated upper right central incisor with mesiodens and a single tooth crossbite. The supernumerary tooth was first extracted and bondable buttons were placed on the rotated tooth, an appliance composed of a removable plate with Adam's clasp with distal extension and a loop for engagement of elastics was delivered. Circumferential supracrestal fibrotomy was performed on the corrected derotated tooth. Then, Hawley's appliance with a z-spring and posterior bite plane was fabricated and placed for correction of crossbite. Thus, this removable appliance can be a simplified and a cost-effective treatment alternative for derotation of anterior tooth, especially during the mixed dentition period. How to cite this article: Sidiq M, Yousuf A, Bhat M, Sharma R, Bhargava N, Ganta S. Correction of a Severely Rotated Maxillary Incisor by Elastics in Mixed Dentition Complicated by a Mesiodens. Int J Clin Pediatr Dent 2015;8(3):234-238.
Miallau, Linda; Hunter, William N; McSweeney, Sean M; Leonard, Gordon A
2007-07-06
High resolution structures of Staphylococcus aureus d-tagatose-6-phosphate kinase (LacC) in two crystal forms are herein reported. The structures define LacC in apoform, in binary complexes with ADP or the co-factor analogue AMP-PNP, and in a ternary complex with AMP-PNP and D-tagatose-6-phosphate. The tertiary structure of the LacC monomer, which is closely related to other members of the pfkB subfamily of carbohydrate kinases, is composed of a large alpha/beta core domain and a smaller, largely beta "lid." Four extended polypeptide segments connect these two domains. Dimerization of LacC occurs via interactions between lid domains, which come together to form a beta-clasp structure. Residues from both subunits contribute to substrate binding. LacC adopts a closed structure required for phosphoryl transfer only when both substrate and co-factor are bound. A reaction mechanism similar to that used by other phosphoryl transferases is proposed, although unusually, when both substrate and co-factor are bound to the enzyme two Mg(2+) ions are observed in the active site. A new motif of amino acid sequence conservation common to the pfkB subfamily of carbohydrate kinases is identified.
Sidiq, Mohsin; Bhat, Manohar; Sharma, Rajesh; Bhargava, Neha; Ganta, Shravani
2015-01-01
ABSTRACT The aim of this case study was to report a potentially convenient approach instead of a conventional orthodontic procedure for correcting severe rotation of anterior tooth of an 11-year-old Indian boy, with a mixed dentition class I malocclusion. The child reported seeking treatment for severely rotated upper right central incisor with mesiodens and a single tooth crossbite. The supernumerary tooth was first extracted and bondable buttons were placed on the rotated tooth, an appliance composed of a removable plate with Adam’s clasp with distal extension and a loop for engagement of elastics was delivered. Circumferential supracrestal fibrotomy was performed on the corrected derotated tooth. Then, Hawley’s appliance with a z-spring and posterior bite plane was fabricated and placed for correction of crossbite. Thus, this removable appliance can be a simplified and a cost-effective treatment alternative for derotation of anterior tooth, especially during the mixed dentition period. How to cite this article: Sidiq M, Yousuf A, Bhat M, Sharma R, Bhargava N, Ganta S. Correction of a Severely Rotated Maxillary Incisor by Elastics in Mixed Dentition Complicated by a Mesiodens. Int J Clin Pediatr Dent 2015;8(3):234-238. PMID:26604544
Miro, Alice; Perrotta, Kim; Evans, Heather; Kishchuk, Natalie A; Gram, Claire; Stanwick, Richard S; Swinkels, Helena M
2014-08-06
The main objective of the Healthy Canada by Design CLASP Initiative in British Columbia (BC) was to develop, implement and evaluate a capacity-building project for health authorities. The desired outcomes of the project were as follows: 1) increased capacity of the participating health authorities to productively engage in land use and transportation planning processes; 2) new and sustained relationships or collaborations among the participating health authorities and among health authorities, local governments and other built environment stakeholders; and 3) indication of health authority influence and/or application of health evidence and tools in land use and transportation plans and policies. This project was designed to enhance the capacity of three regional health authorities, namely Fraser Health, Island Health and Vancouver Coastal Health, and their staff. These were considered the project's participants. The BC regions served by the three health authorities cover the urban, suburban and rural spectrum across relatively large and diverse geographic areas. The populations have broad ranges in socio-economic status, demographic profiles and cultural and political backgrounds. The Initiative provided the three health authorities with a consultant who had several years of experience working on land use and transportation planning. The consultant conducted situational assessments to understand the baseline knowledge and skill gaps, assets and objectives for built environment work for each of the participating health authorities. On the basis of this information, the consultant developed customized capacity-building work plans for each of the health authorities and assisted them with implementation. Capacity-building activities were as follows: researching health and built environment strategies, policies and evidence; transferring health evidence and promising policies and practices from other jurisdictions to local planning contexts; providing training and support with regard to health and the built environment to health authority staff; bringing together public health staff with local planners for networking; and participating in land use planning processes. The project helped to expand the capacity of participating health authorities to influence land use and transportation planning decisions by increasing the content and process expertise of public health staff. The project informed structural changes within health authorities, such as staffing reallocations to advance built environment work after the project. Health authorities also forged new relationships within and across sectors, which facilitated knowledge exchange and access of the public health sector to opportunities to influence built environment decisions. By the end of the project, there was emerging evidence of a health presence in land use policy documents. The project helped to prioritize, accelerate and formalize the participating health authorities' involvement in land use and transportation planning processes. In the long term, this is expected to lead to health policies and programs that consider the built environment, and to built environment policies and practices that integrate population health goals, thereby reducing the risk of chronic diseases.
Measurements of the Magnetic Field of the Upper Chromosphere with Polarimetry
NASA Technical Reports Server (NTRS)
Rachmeler, Laurel; Mckenzie, David; Winebarger, Amy; Kobayashi, Ken; Ishikawa, Ryohko; Kubo, Masahito; Narukage, Noriyuki; Bueno, Trujillo, Javier; Auchere, Frederic
2017-01-01
A major remaining challenge for heliophysics is to decipher the magnetic structure of the chromosphere. The chromosphere is the critical interface between the Sun's photosphere and corona: it contains more mass than the entire interplanetary heliosphere, requires a heating rate that is larger than that of the corona, and mediates all the energy driving the solar wind, solar atmospheric heating and solar eruptions. While measurements of the magnetic field in the photosphere are routine, the chromosphere poses several extra challenges. The magnetically sensitive lines formed in the upper chromosphere are in the ultraviolet, so space-based observations are required. The lines are often formed over a range of heights, sampling different plasma which complicates the inversion process. These lines are sensitive to the magnetic field via polarized light that is created or modified through the Hanle and Zeeman effects. There are a few observations of these lines, and a significant challenge remains in extracting the magnetic field from the polarization measurements, as detailed model atmospheres with advanced radiative transfer physics are needed. Real progress is obtained by a simultaneous improvement in both the observational side and the modeling side. We present information on the CLASP (Chromospheric LAyer Spectro-Polarimeter) sounding rocket program, and future prospects for these types of measurements.
Restoring Anterior Aesthetics by a Rotational Path Cast Partial Denture: An Overlooked Technique
Bhat, Bala Saraswati; Arora, Himanshu
2016-01-01
Cast Partial Dentures (CPD) has long been known to restore missing teeth in patients with minimal invasion on hard and soft tissues. Although satisfactory otherwise, the main concern in CPD is the anterior display of metal. Also the technique sensitive lab procedures, together with the esthetic concern have built an iceberg around the frequent utilization of this treatment modality. With the advent of various techniques to get rid of the metallic display, it was predicted to have more CPD’s done in the dental arena. But the conceptual technicalities of the procedure took away the limelight from this treatment modality and focused on the fixed prosthodontics. Although feasible in a large number of patients, fixed prosthesis still has areas of restriction. It is here, when we apply our knowledge and skill of esthetic CPD. Esthetic CPD eliminates the metal display by utilizing desirable undercuts. The engaging action of the framework into these undercuts paves way for a rotational motion to seat the remaining prosthesis. Hence dual path of insertion helps eliminating the anterior clasp. In this case report dual path of insertion is discussed for replacing anterior teeth in an old male patient who had mild esthetic concerns. Following the conservative approach of CPD (over FPD) esthetic and restorative treatment was planned with patient’s consent. PMID:27437375
High-Reflectivity Coatings for a Vacuum Ultraviolet Spectropolarimeter
NASA Astrophysics Data System (ADS)
Narukage, Noriyuki; Kubo, Masahito; Ishikawa, Ryohko; Ishikawa, Shin-nosuke; Katsukawa, Yukio; Kobiki, Toshihiko; Giono, Gabriel; Kano, Ryouhei; Bando, Takamasa; Tsuneta, Saku; Auchère, Frédéric; Kobayashi, Ken; Winebarger, Amy; McCandless, Jim; Chen, Jianrong; Choi, Joanne
2017-03-01
Precise polarization measurements in the vacuum ultraviolet (VUV) region are expected to be a new tool for inferring the magnetic fields in the upper atmosphere of the Sun. High-reflectivity coatings are key elements to achieving high-throughput optics for precise polarization measurements. We fabricated three types of high-reflectivity coatings for a solar spectropolarimeter in the hydrogen Lyman-α (Lyα; 121.567 nm) region and evaluated their performance. The first high-reflectivity mirror coating offers a reflectivity of more than 80 % in Lyα optics. The second is a reflective narrow-band filter coating that has a peak reflectivity of 57 % in Lyα, whereas its reflectivity in the visible light range is lower than 1/10 of the peak reflectivity (˜ 5 % on average). This coating can be used to easily realize a visible light rejection system, which is indispensable for a solar telescope, while maintaining high throughput in the Lyα line. The third is a high-efficiency reflective polarizing coating that almost exclusively reflects an s-polarized beam at its Brewster angle of 68° with a reflectivity of 55 %. This coating achieves both high polarizing power and high throughput. These coatings contributed to the high-throughput solar VUV spectropolarimeter called the Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP), which was launched on 3 September, 2015.
Present status of titanium removable dentures--a review of the literature.
Ohkubo, C; Hanatani, S; Hosoi, T
2008-09-01
Although porcelain and zirconium oxide might be used for fixed partial dental prostheses instead of conventional dental metals in the near future, removable partial denture (RPD) frameworks will probably continue to be cast with biocompatible metals. Commercially pure (CP) titanium has appropriate mechanical properties, it is lightweight (low density) compared with conventional dental alloys, and has outstanding biocompatibility that prevents metal allergic reactions. This literature review describes the laboratory conditions needed for fabricating titanium frameworks and the present status of titanium removable prostheses. The use of titanium for the production of cast RPD frameworks has gradually increased. There are no reports about metallic allergy apparently caused by CP titanium dentures. The laboratory drawbacks still remain, such as the lengthy burn-out, inferior castability and machinability, reaction layer formed on the cast surface, difficulty of polishing, and high initial costs. However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, have gradually been resolved. Titanium RPD frameworks have never been reported to fail catastrophically. Thus, titanium is recommended as protection against metal allergy, particularly for large-sized prostheses such as RPDs or complete dentures.
Paratonia: a Delphi procedure for consensus definition.
Hobbelen, Johannes S M; Koopmans, Raymond T C M; Verhey, Frans R J; Van Peppen, Roland P S; de Bie, Rob A
2006-01-01
Paratonia is a motor problem that develops during the course of dementia. Definitions of paratonia used in the literature differ considerably, which has clinical implications and may lead to an undesirable heterogeneity in study populations. For this reason, we initiated a Delphi procedure with known experts in the field to establish an operational consensus definition of paratonia. The Delphi procedure involved an anonymous and multistage approach presented as a questionnaire, with each stage building on the results of the previous one in order to reach consensus on the definition of paratonia. Eight of 17 experts agreed to participate in the study. After 4 rounds, the participants reached consensus on the following definition: paratonia is a form of hypertonia with an involuntary variable resistance during passive movement. The nature of paratonia may change with progression of dementia (eg, from active assistance (aka Mitgehen) to active resistance). The degree of resistance depends on the speed of movement (eg, slow > low resistance, fast > high resistance). The degree of paratonia is proportional to the amount of force applied and increases with progression of dementia. The resistance to passive movement is in any direction and there is no clasp-knife phenomenon. The Delphi procedure resulted in a comprehensive, operational definition of paratonia. Future research should focus on the reliability and validity of this definition.
Ahmed, Sarfraz; Sulaiman, Siti Amrah; Baig, Atif Amin; Ibrahim, Muhammad; Liaqat, Sana; Fatima, Saira; Jabeen, Sadia; Shamim, Nighat
2018-01-01
Honey clasps several medicinal and health effects as a natural food supplement. It has been established as a potential therapeutic antioxidant agent for various biodiverse ailments. Data report that it exhibits strong wound healing, antibacterial, anti-inflammatory, antifungal, antiviral, and antidiabetic effects. It also retains immunomodulatory, estrogenic regulatory, antimutagenic, anticancer, and numerous other vigor effects. Data also show that honey, as a conventional therapy, might be a novel antioxidant to abate many of the diseases directly or indirectly associated with oxidative stress. In this review, these wholesome effects have been thoroughly reviewed to underscore the mode of action of honey exploring various possible mechanisms. Evidence-based research intends that honey acts through a modulatory road of multiple signaling pathways and molecular targets. This road contemplates through various pathways such as induction of caspases in apoptosis; stimulation of TNF-α, IL-1β, IFN-γ, IFNGR1, and p53; inhibition of cell proliferation and cell cycle arrest; inhibition of lipoprotein oxidation, IL-1, IL-10, COX-2, and LOXs; and modulation of other diverse targets. The review highlights the research done as well as the apertures to be investigated. The literature suggests that honey administered alone or as adjuvant therapy might be a potential natural antioxidant medicinal agent warranting further experimental and clinical research. PMID:29492183
Aleid, Nouf M.; Fertig, Raymond; Maddy, Austin; Tosti, Antonella
2017-01-01
Background Contact dermatitis of the scalp is common and might be caused by many chemicals including metals, ingredients of shampoos and conditioners, dyes, or other hair treatments. Eliciting a careful history and patch tests are necessary to identify the responsible allergen and prevent relapses. Objectives To identify allergens that may cause contact dermatitis of the scalp by reviewing patch test results. Methods We reviewed the records of 1,015 patients referred for patch testing at the Dermatology Department of the University of Miami. A total of 226 patients (205 females and 21 males) with suspected scalp contact dermatitis were identified, and the patch test results and clinical data for those patients were analyzed. Most patients were referred for patch testing from a specialized hair clinic at our institution. Results The most common allergens in our study population were nickel (23.8%), cobalt (21.0%), balsam of Peru (18.2%), fragrance mix (14.4%), carba mix (11.6%), and propylene glycol (PG) (8.8%). The majority of patients were females aged 40–59 years, and scalp itching or burning were reported as the most common symptom. Conclusion Frequent sources of allergens for metals include hair clasps, pins, and brushes, while frequent sources of allergens for preservatives, fragrance mix, and balsam of Peru include shampoos, conditioners, and hair gels. Frequent sources of allergens for PG include topical medications. PMID:28611994
Lüpold, Stefan; Jin, Long; Liao, Wen Bo
2017-06-01
Sexual selection theory predicts a trade-off between premating (ornaments and armaments) and postmating (testes and ejaculates) sexual traits, assuming that growing and maintaining these traits is costly and that total reproductive investments are limited. The number of males in competition, the reproductive gains from investing in premating sexual traits, and the level of sperm competition are all predicted to influence how males allocate their finite resources to these traits. Yet, empirical examination of these predictions is currently scarce. Here, we studied relative expenditure on pre- and postmating sexual traits among frog species varying in their population density, operational sex ratio, and the number of competing males for each clutch of eggs. We found that the intensifying struggle to monopolize fertilizations as more and more males clasp the same female to fertilize her eggs shifts male reproductive investment toward sperm production and away from male weaponry. This shift, which is mediated by population density and the associated level of male-male competition, likely also explains the trade-off between pre- and postmating sexual traits in our much broader sample of anuran species. Our results highlight the power of such a multilevel approach in resolving the evolution of traits and allocation trade-offs. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.
Sun, J; Jiao, T; Tie, Y; Wang, D-M
2008-09-01
The aim of this study was to evaluate the stress on the abutment teeth and framework ina unilateral maxillary defect which was restored by an obturator retained by resin-bonded extra coronal attachment. A three-dimensional finite element model of the human unilateral maxillary defect was constructed. Traditional obturator framework with four casting circumferential clasp was established (model 1). A continuous lingual guide plane of 0.5 mm thickness on all of the remaining teeth, with Mini-SG/F attachment on the mesial surface of the central incisor was also established (model 2). The modelling and analytical processes were performed using the ANSYS technologies. Stress was transmitted to the anterior part of the palate, with stress values being lower on the anterior teeth compared with the posteriors. The highest stress value of model 1 and model 2 was 13.1 Mpa, 19.9 Mpa respectively. Stress concentrations were found at the junction of the attachment to the lingual guide plane and the anterior part of the lingual plane. The results of this study suggest that the application of a resin-bonded extra coronal attachment for obturator retention is in accordance with the design principles for the restorative treatment of maxillary defects.The design of the attachment framework needs to be further investigated. Benefit can be gained by splinting the abutment teeth.
Xiao, Chaowen; Zhang, Tian; Zheng, Yunzhen
2016-01-01
Xyloglucan constitutes most of the hemicellulose in eudicot primary cell walls and functions in cell wall structure and mechanics. Although Arabidopsis (Arabidopsis thaliana) xxt1 xxt2 mutants lacking detectable xyloglucan are viable, they display growth defects that are suggestive of alterations in wall integrity. To probe the mechanisms underlying these defects, we analyzed cellulose arrangement, microtubule patterning and dynamics, microtubule- and wall-integrity-related gene expression, and cellulose biosynthesis in xxt1 xxt2 plants. We found that cellulose is highly aligned in xxt1 xxt2 cell walls, that its three-dimensional distribution is altered, and that microtubule patterning and stability are aberrant in etiolated xxt1 xxt2 hypocotyls. We also found that the expression levels of microtubule-associated genes, such as MAP70-5 and CLASP, and receptor genes, such as HERK1 and WAK1, were changed in xxt1 xxt2 plants and that cellulose synthase motility is reduced in xxt1 xxt2 cells, corresponding with a reduction in cellulose content. Our results indicate that loss of xyloglucan affects both the stability of the microtubule cytoskeleton and the production and patterning of cellulose in primary cell walls. These findings establish, to our knowledge, new links between wall integrity, cytoskeletal dynamics, and wall synthesis in the regulation of plant morphogenesis. PMID:26527657
Xiao, Chaowen; Zhang, Tian; Zheng, Yunzhen; ...
2015-11-02
Here, xyloglucan constitutes most of the hemicellulose in eudicot primary cell walls and functions in cell wall structure and mechanics. Although Arabidopsis ( Arabidopsis thaliana) xxt1 xxt2 mutants lacking detectable xyloglucan are viable, they display growth defects that are suggestive of alterations in wall integrity. To probe the mechanisms underlying these defects, we analyzed cellulose arrangement, microtubule patterning and dynamics, microtubule- and wall-integrity-related gene expression, and cellulose biosynthesis in xxt1 xxt2 plants. We found that cellulose is highly aligned in xxt1 xxt2 cell walls, that its three-dimensional distribution is altered, and that microtubule patterning and stability are aberrant in etiolatedmore » xxt1 xxt2 hypocotyls. We also found that the expression levels of microtubule-associated genes, such as MAP70-5 and CLASP, and receptor genes, such as HERK1 and WAK1, were changed in xxt1 xxt2 plants and that cellulose synthase motility is reduced in xxt1 xxt2 cells, corresponding with a reduction in cellulose content. Our results indicate that loss of xyloglucan affects both the stability of the microtubule cytoskeleton and the production and patterning of cellulose in primary cell walls. These findings establish, to our knowledge, new links between wall integrity, cytoskeletal dynamics, and wall synthesis in the regulation of plant morphogenesis.« less
Vallotto, Davide; Bresseel, Joachim; Heitzmann, Thierry; Gottardo, Marco
2016-01-01
Abstract A new stick insect of the genus Orthomeria Kirby, 1904 (Phasmatodea, Aschiphasmatidae) is described from the Philippines. Orthomeria (Orthomeria) kangi sp. n. is readily distinguished from all other congeners by the distinctive blood red colouration of the costal region of the hind wings. Major features of the external morphology of adults, eggs, and first-instar nymphs are illustrated. Locomotory attachment pads are of the smooth type with irregular microgrooves on the contact surface. An unusual condition of male terminalia is the absence of tergal thorn pads on segment 10. The male clasping organs are represented by an elongated vomer terminating in a prominent spine, and by incurved cerci featuring a bilobed apex equipped with a sharp blade-like ridge. Intraspecific variation in body colouration and hind wing length occurs in females. The new species lives at 400-650 m elevation in the surroundings of the Sablang and Tuba regions, in the Benguet Province of Luzon island. Host plants include Ficus spp. (Moraceae), and Pipturus spp. and Leucosyke spp. (Urticaceae). Observations on the mating and defensive behaviour are presented. Orthomeria (Orthomeria) catadromus (Westwood, 1859) is recognised as a junior synonym of Orthomeria (Orthomeria) pandora (Westwood, 1859), syn. n. A lectotype is designated for both species. Finally, an updated identification key to the species of the subgenus Orthomeria is provided. PMID:27006604
Xiao, Chaowen; Zhang, Tian; Zheng, Yunzhen; Cosgrove, Daniel J; Anderson, Charles T
2016-01-01
Xyloglucan constitutes most of the hemicellulose in eudicot primary cell walls and functions in cell wall structure and mechanics. Although Arabidopsis (Arabidopsis thaliana) xxt1 xxt2 mutants lacking detectable xyloglucan are viable, they display growth defects that are suggestive of alterations in wall integrity. To probe the mechanisms underlying these defects, we analyzed cellulose arrangement, microtubule patterning and dynamics, microtubule- and wall-integrity-related gene expression, and cellulose biosynthesis in xxt1 xxt2 plants. We found that cellulose is highly aligned in xxt1 xxt2 cell walls, that its three-dimensional distribution is altered, and that microtubule patterning and stability are aberrant in etiolated xxt1 xxt2 hypocotyls. We also found that the expression levels of microtubule-associated genes, such as MAP70-5 and CLASP, and receptor genes, such as HERK1 and WAK1, were changed in xxt1 xxt2 plants and that cellulose synthase motility is reduced in xxt1 xxt2 cells, corresponding with a reduction in cellulose content. Our results indicate that loss of xyloglucan affects both the stability of the microtubule cytoskeleton and the production and patterning of cellulose in primary cell walls. These findings establish, to our knowledge, new links between wall integrity, cytoskeletal dynamics, and wall synthesis in the regulation of plant morphogenesis. © 2016 American Society of Plant Biologists. All Rights Reserved.
Dissociation of agency and body ownership following visuomotor temporal recalibration
Imaizumi, Shu; Asai, Tomohisa
2015-01-01
Bodily self-consciousness consists of one’s sense of agency (I am causing an action) and body ownership (my body belongs to me). Both stem from the temporal congruence between different modalities, although some visuomotor temporal incongruence is acceptable for agency. To examine the association or dissociation between agency and body ownership in the context of different temporal sensitivities, we applied a temporal recalibration paradigm, in which subjective synchrony between asynchronous hand action and its visual feedback can be perceived after exposure to the asynchronous visuomotor stimulation. In the experiment, participants continuously clasped and unclasped their hand while watching an online video of their hand that was presented with delays of 50, 110, 170, 230, 290, and 350 ms. Then, they rated a video of their hand with a delay of 50 ms (test stimulus) with respect to the synchrony between hand action and hand video and the perceived agency over the video. Moreover, proprioceptive drift of participants’ hand location toward the hand video during the exposure was measured as an index of illusory body ownership. Results indicated that perception of agency emerged over the delayed hand video as subjective visuomotor synchrony was recalibrated, but that body ownership did not emerge for the delayed video, even after the recalibration. We suggest that there is a dissociation between agency and body ownership following visuomotor temporal recalibration. PMID:25999826
[Computer aided design and rapid manufacturing of removable partial denture frameworks].
Han, Jing; Lü, Pei-jun; Wang, Yong
2010-08-01
To introduce a method of digital modeling and fabricating removable partial denture (RPD) frameworks using self-developed software for RPD design and rapid manufacturing system. The three-dimensional data of two partially dentate dental casts were obtained using a three-dimensional crossing section scanner. Self-developed software package for RPD design was used to decide the path of insertion and to design different components of RPD frameworks. The components included occlusal rest, clasp, lingual bar, polymeric retention framework and maxillary major connector. The design procedure for the components was as following: first, determine the outline of the component. Second, build the tissue surface of the component using the scanned data within the outline. Third, preset cross section was used to produce the polished surface. Finally, different RPD components were modeled respectively and connected by minor connectors to form an integrated RPD framework. The finished data were imported into a self-developed selective laser melting (SLM) machine and metal frameworks were fabricated directly. RPD frameworks for the two scanned dental casts were modeled with this self-developed program and metal RPD frameworks were successfully fabricated using SLM method. The finished metal frameworks fit well on the plaster models. The self-developed computer aided design and computer aided manufacture (CAD-CAM) system for RPD design and fabrication has completely independent intellectual property rights. It provides a new method of manufacturing metal RPD frameworks.
Vallotto, Davide; Bresseel, Joachim; Heitzmann, Thierry; Gottardo, Marco
2016-01-01
A new stick insect of the genus Orthomeria Kirby, 1904 (Phasmatodea, Aschiphasmatidae) is described from the Philippines. Orthomeria (Orthomeria) kangi sp. n. is readily distinguished from all other congeners by the distinctive blood red colouration of the costal region of the hind wings. Major features of the external morphology of adults, eggs, and first-instar nymphs are illustrated. Locomotory attachment pads are of the smooth type with irregular microgrooves on the contact surface. An unusual condition of male terminalia is the absence of tergal thorn pads on segment 10. The male clasping organs are represented by an elongated vomer terminating in a prominent spine, and by incurved cerci featuring a bilobed apex equipped with a sharp blade-like ridge. Intraspecific variation in body colouration and hind wing length occurs in females. The new species lives at 400-650 m elevation in the surroundings of the Sablang and Tuba regions, in the Benguet Province of Luzon island. Host plants include Ficus spp. (Moraceae), and Pipturus spp. and Leucosyke spp. (Urticaceae). Observations on the mating and defensive behaviour are presented. Orthomeria (Orthomeria) catadromus (Westwood, 1859) is recognised as a junior synonym of Orthomeria (Orthomeria) pandora (Westwood, 1859), syn. n. A lectotype is designated for both species. Finally, an updated identification key to the species of the subgenus Orthomeria is provided.
Lieu, Christopher A.; Chinta, Shankar J.; Rane, Anand; Andersen, Julie K.
2013-01-01
We have previously shown that increases in astrocytic monoamine oxidase-B (MAO-B) expression, mimicking that which occurs with aging and in neurodegenerative disease, in a doxycycline (dox)-inducible transgenic mouse model evokes neuropathological similarities to what is observed in the human parkinsonian brain. Additional behavioral and neuropathological studies could provide further validation for its usage as a model for Parkinson’s disease (PD). In the present study, we utilized a battery of behavioral tests to evaluate age-related phenotype in this model. In the open field test, we found that dox-induction impaired motor ability with decreases in movement and ambulatory function as well as diminished stereotypical, repetitive movement episodes in both young and old mice. Older mice also showed decreased motor performance in the pole test when compared to younger mice. Furthermore, dox-induced older mice displayed severe hindlimb clasping and the most significant loss of dopamine (DA) in the striatum when compared to young and non-induced animals. Additionally, increased MAO-B activity significantly correlated with decreased expression of striatal DA. The results of our study further confirms that the dox-inducible astrocytic MAO-B transgenic mouse displays similar age-related behavioral and neuropathological features to other models of PD, and could serve as a useful tool to study PD pathophysiology and for the evaluation of therapeutic interventions. PMID:23326597
Lieu, Christopher A; Chinta, Shankar J; Rane, Anand; Andersen, Julie K
2013-01-01
We have previously shown that increases in astrocytic monoamine oxidase-B (MAO-B) expression, mimicking that which occurs with aging and in neurodegenerative disease, in a doxycycline (dox)-inducible transgenic mouse model evokes neuropathological similarities to what is observed in the human parkinsonian brain. Additional behavioral and neuropathological studies could provide further validation for its usage as a model for Parkinson's disease (PD). In the present study, we utilized a battery of behavioral tests to evaluate age-related phenotype in this model. In the open field test, we found that dox-induction impaired motor ability with decreases in movement and ambulatory function as well as diminished stereotypical, repetitive movement episodes in both young and old mice. Older mice also showed decreased motor performance in the pole test when compared to younger mice. Furthermore, dox-induced older mice displayed severe hindlimb clasping and the most significant loss of dopamine (DA) in the striatum when compared to young and non-induced animals. Additionally, increased MAO-B activity significantly correlated with decreased expression of striatal DA. The results of our study further confirms that the dox-inducible astrocytic MAO-B transgenic mouse displays similar age-related behavioral and neuropathological features to other models of PD, and could serve as a useful tool to study PD pathophysiology and for the evaluation of therapeutic interventions.
Carter, Chris G; Westbury, Heath; Crear, Bradley; Simon, Cedric; Thomas, Craig
2014-01-01
The Southern rock lobster, Jasusedwardsii, is a temperate species of spiny lobster with established well managed fisheries in Australia and New Zealand. It has also been under consideration as a species with aquaculture potential. Agonistic behaviour has important consequences under aquaculture conditions that encompass direct effects, such as damage or death of protagonists, and indirect effects on growth that relate to resource access, principally food and refuge. This study aimed to identify and characterize behaviours and to make a preliminary investigation of their occurrence under tank culture. Juvenile Jasusedwardsii were examined in a flow-through seawater system using a remote video camera system. Twenty-nine behaviours were divided into three sub-groups: aggressive (11), avoidance (6) and others (12). Aggressive behaviours included attacks, pushing, lifting, clasping and carrying an opponent. Avoidance behaviours included moving away in a backwards-, forwards- or side-stepping motion as well as with more vigorous tail flips. These behaviours were components of twelve behavioural groups that described contact, attack and displacement between individuals. Activity was crepuscular with two clear peaks, one in the morning and the other in the evening. The occurrence of behavioural groups was not different between the morning and evening. The frequency of aggressive behaviours was not affected by changes made to stocking density or access to food. The implications of agonistic behaviours are discussed further in relation to developing aquaculture.
Reconstructing the Lethal Part of the 1790 Eruption at Kilauea
NASA Astrophysics Data System (ADS)
Swanson, D.; Weaver, S. J.; Houghton, B. F.
2011-12-01
The most lethal known eruption from a volcano in the United States took place in November 1790 at Kilauea, killing perhaps 400-800 people (estimates range widely) who were crossing the summit on their way to a distant battle site. The eruption culminated ca. 300 years of sporadic explosive activity after the formation of Kilauea Caldera in about 1500. No contemporary account exists of the 1790 activity, but an eruption plume was observed from Kawaihae, 100 km NW of Kilauea, that probably was 10 km or higher. We are attempting to piece together the lethal event from a study of the 1790 and enclosing deposits and by using published accounts, written several decades later, based on interviews with survivors or others with knowledge of the tragedy. Determining what deposits actually formed in November 1790 is crucial. The best tie to that date is a deposit of phreatomagmatic lithic lapilli and ash that occurs SE of the caldera and must have been advected by high-level (>~10 km) westerly winds rather than low-level NE trade winds. It is the only contender for deposits from the high column observed in 1790. Small lapilli from the high column fell onto, and sank deeply into, a 3-5-cm-thick accretionary lapilli layer that was wet and likely no more than a few hours old. The wet ash occurs south of the caldera, where the lithic lapilli fell into it, and is also found west of the caldera in the saddle between Kilauea and Mauna Loa, where the victims were probably walking along a main foot trail still visible today. A lithic pyroclastic surge swept across the saddle, locally scouring away the wet accretionary lapilli layer but generally leaving a deposit <1 to 15 cm thick on the ash and embedding 1-cm lithic lapilli deeply within it. This indicates that the surge also erupted in November 1790, while the underlying ash was still wet. Though scattered ballistic blocks later fell in the area, the surge left the youngest continuous deposit on the west flank of Kilauea. An account written in 1843 by Rev. Sheldon Dibble describes the dead victims as lying on the surface or "sitting upright clasping with dying grasp their wives and children," not buried by ash or battered by falling debris, and "thoroughly scorched" but "in no place deeply burnt." These gruesome details suggest that the surge engulfed the victims, some of whom were clasping one another to keep from being blown away. The surge deposit covers an area of 12-15 sq km on the western flank of Kilauea between the Hawaiian Volcano Observatory (HVO) and the main highway around the island. The fatalities probably took place in this area, now visited daily by 5000 travelers to Hawai`i Volcanoes National Park. Several human footprints, barely discernible through the thin surge deposit, indent the surface of the accretionary lapilli ash near HVO. Do they record someone's last footsteps? We do not yet know when the eruption started or how many units older than the accretionary lapilli ash were also erupted in 1790. But we think we have identified the lethal surge of the eruption, and it is sobering to realize that it overwhelmed the place where this abstract is being written 221 years later.
Assessing Student Peer Dialogue in Collaborative Settings: A Window into Student Reasoning
NASA Astrophysics Data System (ADS)
Stone, Antoinette
The use of science classroom discourse analysis as a way to gain a better understanding of various student cognitive outcomes has a rich history in Science Education in general and Physics Education Research (PER) in particular. When students talk to each other in a collaborative peer instruction environment, such as in the CLASP classes (Collaborative Learning and Sense-making in Physics) at UC Davis, they get to practice and enhance their reasoning and sense-making skills, develop collaborative approaches to problem solving, and participate in co-construction of knowledge and shared thinking. To better understand these important cognitive processes, an analysis tool for monitoring, assessing and categorizing the peer talk arising in this environment is needed as a first step in teasing out evidence for these processes inherent in such talk. In order to meaningfully contribute to the extensive body of knowledge that currently exists, deeper, more insightful answers to the question of what happens linguistically when students struggle to "make sense" and how students use language to mediate these important cognitive outcomes is needed. To this end, a new tool for interpreting particularly qualitative linguistic data is needed, and the first part of the dissertation expounds on the development of a discourse analysis tool that has as its underpinnings a framework for coding borrowed extensively from Systemic Functional Linguistics Theory (SFL). The second part of this dissertation illustrates multiple ways in which the tool is used and how it can be utilized to address many current research questions.
NASA Technical Reports Server (NTRS)
Yun, Gunjin; Abdullah, A. B. M.; Binienda, Wieslaw; Krause, David L.; Kalluri, Sreeramesh
2014-01-01
A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses
Sexual selection and allometry: a critical reappraisal of the evidence and ideas.
Bonduriansky, Russell
2007-04-01
One of the most pervasive ideas in the sexual selection literature is the belief that sexually selected traits almost universally exhibit positive static allometries (i.e., within a sample of conspecific adults, larger individuals have disproportionally larger traits). In this review, I show that this idea is contradicted by empirical evidence and theory. Although positive allometry is a typical attribute of some sexual traits in certain groups, the preponderance of positively allometric sexual traits in the empirical literature apparently results from a sampling bias reflecting a fascination with unusually exaggerated (bizarre) traits. I review empirical examples from a broad range of taxa illustrating the diversity of allometric patterns exhibited by signal, weapon, clasping and genital traits, as well as nonsexual traits. This evidence suggests that positive allometry may be the exception rather than the rule in sexual traits, that directional sexual selection does not necessarily lead to the evolution of positive allometry and, conversely, that positive allometry is not necessarily a consequence of sexual selection, and that many sexual traits exhibit sex differences in allometric intercept rather than slope. Such diversity in the allometries of secondary sexual traits is to be expected, given that optimal allometry should reflect resource allocation trade-offs, and patterns of sexual and viability selection on both trait size and body size. An unbiased empirical assessment of the relation between sexual selection and allometry is an essential step towards an understanding of this diversity.
Kenett, Dror Y; Tumminello, Michele; Madi, Asaf; Gur-Gershgoren, Gitit; Mantegna, Rosario N; Ben-Jacob, Eshel
2010-12-20
What are the dominant stocks which drive the correlations present among stocks traded in a stock market? Can a correlation analysis provide an answer to this question? In the past, correlation based networks have been proposed as a tool to uncover the underlying backbone of the market. Correlation based networks represent the stocks and their relationships, which are then investigated using different network theory methodologies. Here we introduce a new concept to tackle the above question--the partial correlation network. Partial correlation is a measure of how the correlation between two variables, e.g., stock returns, is affected by a third variable. By using it we define a proxy of stock influence, which is then used to construct partial correlation networks. The empirical part of this study is performed on a specific financial system, namely the set of 300 highly capitalized stocks traded at the New York Stock Exchange, in the time period 2001-2003. By constructing the partial correlation network, unlike the case of standard correlation based networks, we find that stocks belonging to the financial sector and, in particular, to the investment services sub-sector, are the most influential stocks affecting the correlation profile of the system. Using a moving window analysis, we find that the strong influence of the financial stocks is conserved across time for the investigated trading period. Our findings shed a new light on the underlying mechanisms and driving forces controlling the correlation profile observed in a financial market.
Zarrati, Simindokht; Bahrami, Mehran; Heidari, Fatemeh; Kashani, Jamal
2015-06-01
This finite element method study aimed to compare the amount of stress on an isolated mandibular second premolar in two conventional reciprocal parallel interface designs of removable partial dentures (RPDs) and the same RPD abutment tooth (not isolated). A Kennedy Class 1, modification 1 RPD framework was simulated on a 3D model of mandible with three different designs: an isolated tooth with a mesial rest, an isolated tooth with mesial and distal rests and an abutment with a mesial rest (which was not isolated); 26 N occlusal forces were exerted bilaterally on the first molar sites. Stress on the abutment teeth was analyzed using Cosmos Works 2009 Software. In all designs, the abutment tooth stress concentration was located in the buccal alveolar crest. In the first model, the von Mises stress distribution in the contact area of I-bar clasp and cervical portion of the tooth was 19 MPa and the maximum stress was 30 MPa. In the second model, the maximum von Mises stress distribution was 15 MPa in the cervical of the tooth. In the third model, the maximum von Mises stress was located in the cervical of the tooth and the distal proximal plate. We recommend using both mesial and distal rests on the distal abutment teeth of distal extension RPDs. The abutment of an extension base RPD, which is not isolated in presence of its neighboring more anterior tooth, may have a better biomechanical prognosis.
Mackay, Bev; Harding, Thomas; Jurlina, Lou; Scobie, Norma; Khan, Ruelle
2011-04-01
The rising number of international students studying outside their own country poses challenges for nursing education. Numbers are predicted to grow and economic factors are placing increasing pressure on tertiary institutions to accept these students. In adapting to a foreign learning environment international students must not only adapt to the academic culture but also to the socio-cultural context. The most significant acculturation issues for students are English as a second language, differences in education pedagogy and social integration and connectedness. Students studying in New Zealand need to work with Maori, the indigenous people, and assimilate and practice the unique aspects of cultural safety, which has evolved in nursing as part of the response to the principles underpinning the Treaty of Waitangi. The Hand Model offers the potential to support international students in a culturally safe manner across all aspects of acculturation including those aspects of cultural safety unique to New Zealand. The model was originally developed by Lou Jurlina, a nursing teacher, to assist her to teach cultural safety and support her students in practising cultural safety in nursing. The thumb, represents 'awareness', with the other four digits signifying 'connection" 'communication', 'negotiation' and 'advocacy' respectively. Each digit is connected to the palm where the ultimate evaluation of the Hand Model in promoting cultural safety culminates in the clasping and shaking of hands: the moment of shared meaning. It promotes a sense of self worth and identity in students and a safe environment in which they can learn.
Implant prostheses for convertibility, stress control, esthetics, and hygiene.
Garfield, R E
1988-07-01
A method of connecting "fixed partial denture" prostheses to osseointegrated implant fixtures has been described. The advantages of this system of restoration for partially and fully edentulous mouths are that it is more effective in addressing the problems of (1) stress-control on abutments, (2) a back-up system for abutment failures, (3) esthetics, and (4) control of bacterial plaques around abutments. To accomplish this procedure, the application of convertible periodontal prosthesis techniques with modifications to some existing implant systems is undertaken. The disadvantages of this method seem insignificant when one considers the complexities and risks involved with the present array of implant prosthesis alternatives. Some patients and dentists might consider the necessity of the prosthesis being detachable as one disadvantage. In reality, the prosthesis can be used as a fixed restoration until the patient has fully adapted to the new proprioception and appearance. A large percentage of patients feel uncomfortable with the word "removable" because it immediately creates a perception of unsightly metallic clasp display, palatal coverage, tongue interference, and negative body image. The use of the term "detachable" coupled with the doctor's offer to perform this task for the patient "whenever necessary" will usually relieve the patient's anxiety and allow the treatment to proceed. Once neuromuscular and esthetic adaptation have occurred and the patient has accepted the prosthesis, daily detaching and home-care hygiene by the patient will follow without incident. Esthetic improvement is obvious (Fig. 3).
Eddy Covariance Measurements of the Sea-Spray Aerosol Flu
NASA Astrophysics Data System (ADS)
Brooks, I. M.; Norris, S. J.; Yelland, M. J.; Pascal, R. W.; Prytherch, J.
2015-12-01
Historically, almost all estimates of the sea-spray aerosol source flux have been inferred through various indirect methods. Direct estimates via eddy covariance have been attempted by only a handful of studies, most of which measured only the total number flux, or achieved rather coarse size segregation. Applying eddy covariance to the measurement of sea-spray fluxes is challenging: most instrumentation must be located in a laboratory space requiring long sample lines to an inlet collocated with a sonic anemometer; however, larger particles are easily lost to the walls of the sample line. Marine particle concentrations are generally low, requiring a high sample volume to achieve adequate statistics. The highly hygroscopic nature of sea salt means particles change size rapidly with fluctuations in relative humidity; this introduces an apparent bias in flux measurements if particles are sized at ambient humidity. The Compact Lightweight Aerosol Spectrometer Probe (CLASP) was developed specifically to make high rate measurements of aerosol size distributions for use in eddy covariance measurements, and the instrument and data processing and analysis techniques have been refined over the course of several projects. Here we will review some of the issues and limitations related to making eddy covariance measurements of the sea spray source flux over the open ocean, summarise some key results from the last decade, and present new results from a 3-year long ship-based measurement campaign as part of the WAGES project. Finally we will consider requirements for future progress.
Christian, Danielle; Todd, Charlotte; Davies, Helen; Rance, Jaynie; Stratton, Gareth; Rapport, Frances; Brophy, Sinead
2015-03-13
Schools are repeatedly utilised as a key setting for health interventions. However, the translation of effective research findings to the school setting can be problematic. In order to improve effective translation of future interventions, it is imperative key challenges and facilitators of implementing health interventions be understood from a school's perspective. Nineteen semi-structured interviews were conducted in primary schools (headteachers n = 16, deputy headteacher n = 1, healthy school co-ordinator n = 2). Interviews were transcribed verbatim and analysed using thematic analysis. The main challenges for schools in implementing health interventions were; government-led academic priorities, initiative overload, low autonomy for schools, lack of staff support, lack of facilities and resources, litigation risk and parental engagement. Recommendations to increase the application of interventions into the school setting included; better planning and organisation, greater collaboration with schools and external partners and elements addressing sustainability. Child-centred and cross-curricular approaches, inclusive whole school approaches and assurances to be supportive of the school ethos were also favoured for consideration. This work explores schools' perspectives regarding the implementation of health interventions and utilises these thoughts to create guidelines for developing future school-based interventions. Recommendations include the need to account for variability between school environments, staff and pupils. Interventions with an element of adaptability were preferred over the delivery of blanket fixed interventions. Involving schools in the developmental stage would add useful insights to ensure the interventions can be tailored to best suit each individual schools' needs and improve implementation.
Zaoui, Kossay; Benseddik, Khedidja; Daou, Pascale; Salaün, Danièle; Badache, Ali
2010-10-26
Microtubules (MTs) contribute to key processes during cell motility, including the regulation of focal adhesion turnover and the establishment and maintenance of cell orientation. It was previously demonstrated that the ErbB2 receptor tyrosine kinase regulated MT outgrowth to the cell cortex via a complex including Memo, the GTPase RhoA, and the formin mDia1. But the mechanism that linked this signaling module to MTs remained undefined. We report that ErbB2-induced repression of glycogen synthase kinase-3 (GSK3) activity, mediated by Memo and mDia1, is required for MT capture and stabilization. Memo-dependent inhibition of GSK3 allows the relocalization of APC (adenomatous polyposis coli) and cytoplasmic linker-associated protein 2 (CLASP2), known MT-associated proteins, to the plasma membrane and ruffles. Peripheral microtubule extension also requires expression of the plus-end binding protein EB1 and its recently described interactor, the spectraplakin ACF7. In fact, in migrating cells, ACF7 localizes to the plasma membrane and ruffles, in a Memo-, GSK3-, and APC-dependent manner. Finally, we demonstrate that ACF7 targeting to the plasma membrane is both required and sufficient for MT capture downstream of ErbB2. This function of ACF7 does not require its recently described ATPase activity. By defining the signaling pathway by which ErbB2 allows MT capture and stabilization at the cell leading edge, we provide insights into the mechanism underlying cell motility and steering.
Gogliotti, Rocco G.; Senter, Rebecca K.; Rook, Jerri M.; Ghoshal, Ayan; Zamorano, Rocio; Malosh, Chrysa; Stauffer, Shaun R.; Bridges, Thomas M.; Bartolome, Jose M.; Daniels, J. Scott; Jones, Carrie K.; Lindsley, Craig W.; Conn, P. Jeffrey; Niswender, Colleen M.
2016-01-01
Rett syndrome (RS) is a neurodevelopmental disorder that shares many symptomatic and pathological commonalities with idiopathic autism. Alterations in protein synthesis-dependent synaptic plasticity (PSDSP) are a hallmark of a number of syndromic forms of autism; in the present work, we explore the consequences of disruption and rescue of PSDSP in a mouse model of RS. We report that expression of a key regulator of synaptic protein synthesis, the metabotropic glutamate receptor 5 (mGlu5) protein, is significantly reduced in both the brains of RS model mice and in the motor cortex of human RS autopsy samples. Furthermore, we demonstrate that reduced mGlu5 expression correlates with attenuated DHPG-induced long-term depression in the hippocampus of RS model mice, and that administration of a novel mGlu5 positive allosteric modulator (PAM), termed VU0462807, can rescue synaptic plasticity defects. Additionally, treatment of Mecp2-deficient mice with VU0462807 improves motor performance (open-field behavior and gait dynamics), corrects repetitive clasping behavior, as well as normalizes cued fear-conditioning defects. Importantly, due to the rationale drug discovery approach used in its development, our novel mGlu5 PAM improves RS phenotypes and synaptic plasticity defects without evoking the overt adverse effects commonly associated with potentiation of mGlu5 signaling (i.e. seizures), or affecting cardiorespiratory defects in RS model mice. These findings provide strong support for the continued development of mGlu5 PAMs as potential therapeutic agents for use in RS, and, more broadly, for utility in idiopathic autism. PMID:26936821
Three-dimensional reconstruction and the phylogeny of extinct chelicerate orders
Dunlop, Jason
2014-01-01
Arachnids are an important group of arthropods. They are: diverse and abundant; a major constituent of many terrestrial ecosystems; and possess a deep and extensive fossil record. In recent years a number of exceptionally preserved arachnid fossils have been investigated using tomography and associated techniques, providing valuable insights into their morphology. Here we use X-ray microtomography to reconstruct members of two extinct arachnid orders. In the Haptopoda, we demonstrate the presence of ‘clasp-knife’ chelicerae, and our novel redescription of a member of the Phalangiotarbida highlights leg details, but fails to resolve chelicerae in the group due to their small size. As a result of these reconstructions, tomographic studies of three-dimensionally preserved fossils now exist for three of the four extinct orders, and for fossil representatives of several extant ones. Such studies constitute a valuable source of high fidelity data for constructing phylogenies. To illustrate this, here we present a cladistic analysis of the chelicerates to accompany these reconstructions. This is based on a previously published matrix, expanded to include fossil taxa and relevant characters, and allows us to: cladistically place the extinct arachnid orders; explicitly test some earlier hypotheses from the literature; and demonstrate that the addition of fossils to phylogenetic analyses can have broad implications. Phylogenies based on chelicerate morphology—in contrast to molecular studies—have achieved elements of consensus in recent years. Our work suggests that these results are not robust to the addition of novel characters or fossil taxa. Hypotheses surrounding chelicerate phylogeny remain in a state of flux. PMID:25405073
2010-01-01
Background It is well known that many anurans do not reproduce easily in captivity. Some methods are based on administration of mammalian hormones such as human chorionic gonadotropin, which are not effective in many frogs. There is a need for simple, cost-effective alternative techniques to induce spawning. Methods Our new method is based on the injection of a combination of a gonadotropin-releasing hormone (GnRH) agonist and a dopamine antagonist. We have named this formulation AMPHIPLEX, which is derived from the combination of the words amphibian and amplexus. This name refers to the specific reproductive behavior of frogs when the male mounts and clasps the female to induce ovulation and to fertilize the eggs as they are laid. Results We describe the use of the method and demonstrate its applicability for captive breeding in 3 different anuran families. We tested several combinations of GnRH agonists with dopamine antagonists using Lithobates pipiens. The combination of des-Gly10, D-Ala6, Pro-LHRH (0.4 microrams/g body weight) and metoclopramide (10 micrograms/g BWt. MET) was most effective. It was used in-season, after short-term captivity and in frogs artificially hibernated under laboratory conditions. The AMPHIPLEX method was also effective in 3 Argentinian frogs, Ceratophrys ornata, Ceratophrys cranwelli and Odontophrynus americanus. Conclusion Our approach offers some advantages over other hormonally-based techniques. Both sexes are injected only once and at the same time, reducing handling stress. AMPHIPLEX is a new reproductive management tool for captive breeding in Anura. PMID:20398399
Elucidation of Kinetic Mechanisms of Human Translesion DNA Polymerase κ Using Tryptophan Mutants
Zhao, Linlin; Pence, Matthew G.; Eoff, Robert L.; Yuan, Shuai; Fercu, Catinca A.; Guengerich, F. Peter
2014-01-01
In order to investigate the conformational dynamics of human DNA polymerase κ (hpol κ), we generated two mutants, Y50W (N-clasp region) and Y408W (linker between the thumb and little finger domains), using a Trp-null mutant (W214Y/W392H) of the hpol κ catalytic core enzyme. These mutants retained catalytic activity and similar patterns of selectivity for bypassing the DNA adduct 7,8-dihydro-8-oxo-2′-deoxyguanosine (8-oxoG), as judged by the results of steady-state and pre-steady-state kinetic experiments. Stopped-flow kinetic assays with hpol κ Y50W and T408W revealed a decrease in Trp fluorescence with the template G:dCTP pair but not for any mispairs. This decrease in fluorescence was not rate-limiting and is considered to be related to a conformational change necessary for correct nucleotidyl transfer. When a free 3′-hydroxyl was present on the primer, the Trp fluorescence returned to the baseline level at a rate similar to the observed kcat, suggesting that this change occurs during or after nucleotidyl transfer. However, polymerization rates (kpol) of extended-product formation were fast, indicating that the slow fluorescence step follows phosphodiester bond formation and is rate-limiting. Pyrophosphate formation and release were fast and are likely to precede the slower relaxation step. The available kinetic data were used to fit a simplified minimal model. The extracted rate constants confirmed that the conformational change after phosphodiester formation was rate-limiting for hpol κ catalysis with the template G:dCTP pair. PMID:25065501
Dula, Linda J; Shala, Kujtim Sh; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F
2015-01-01
The aim of this study was to evaluate the influence of removable partial dentures (RPD) on the periodontal health of abutment and non-abutment teeth. A total 107 patients with RPD participated in this study. It was examined 138 RPD, they were 87 with clasp-retained and 51 were RPD with attachments. The following periodontal parameters were evaluated for abutment and non-abutment teeth, plaque index (PLI), calculus index (CI), bleeding on probing (BOP), probing depth (PD) (mm) and tooth mobility (TM) index. These clinical measurements were taken immediately before insertion the RPD, then one and 3 months after insertion. The level of significance was set at (P < 0.05). The mean scores for PLI, CI, BOP, PD, and TM index, of the abutment teeth and non-abutment teeth were no statistically significant at the time of insertion of RPD. After 1-month, PLI was statistically significant (0.57 ± 0.55 for abutment and 0.30 ± 0.46 for non-abutment teeth). After 3 months, there were significant differences between abutment and non-abutment teeth with regard to the BOP (1.53 ± 0.50 and 1.76 ± 0.43 respectively), PD (0.28 ± 0.45 and 0.12 ± 0.33 respectively) and PLI (1.20 ± 0.46 and 0.75 ± 0.64 respectively). No significant mean difference in TM and CI was found between the abutment and non-abutment teeth (P > 0.05). With carefully planned prosthetic treatment and adequate maintenance of the oral and denture hygiene, we can prevent the periodontal diseases.
Rovira-Lastra, B; Flores-Orozco, E I; Ayuso-Montero, R; Peraire, M; Martinez-Gomis, J
2016-04-01
The aim of this cross-sectional study was to determine the preferred chewing side and whether chewing side preference is related to peripheral, functional or postural lateral preferences. One hundred and forty-six adults with natural dentition performed three masticatory assays, each consisting of five trials of chewing three pieces of silicon placed into a latex bag for 20 cycles, either freestyle or unilaterally on the right- or left-hand side. Occlusal contact area in the intercuspal position, maximum bite force, masticatory performance and cycle duration were measured and the lateral asymmetry of these variables was calculated. Laterality tests were performed to determine handedness, footedness, earedness and eyedness as functional preferences, and hand-clasping, arm-folding and leg-crossing as postural lateral preferences. The preferred chewing side was determined using three different methods: assessment of the first chewing cycle for each trial, calculation of the asymmetry index from all cycles and application of a visual analogue scale. Bivariate relationship and multiple linear regression analyses were performed. Among unilateral chewers, 77% of them preferred the right side for chewing. The factors most closely related to the preferred chewing side were asymmetry of bite force, asymmetry of masticatory performance and earedness, which explained up to 16% of the variance. Although several functional or postural lateral preferences seem to be related to the preferred chewing side, peripheral factors such as asymmetry of bite force and of masticatory performance are the most closely related to the preferred chewing side in adults with natural dentition. © 2015 John Wiley & Sons Ltd.
Assessment of the Impacts of Standards and Labeling Programs inMexico (four products).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez, Itha; Pulido, Henry; McNeil, Michael A.
2007-06-12
This study analyzes impacts from energy efficiency standards and labeling in Mexico from 1994 through 2005 for four major products: household refrigerators, room air conditioners, three-phase (squirrel cage) induction motors, and clothes washers. It is a retrospective analysis, seeking to assess verified impacts on product efficiency in the Mexican market in the first ten years after standards were implemented. Such an analysis allows the Mexican government to compare actual to originally forecast program benefits. In addition, it provides an extremely valuable benchmark for other countries considering standards, and to the energy policy community as a whole. The methodology for evaluationmore » begins with historical test data taken for a large number of models of each product type between 1994 and 2005. The pre-standard efficiency of models in 1994 is taken as a baseline throughout the analysis. Model efficiency data were provided by an independent certification laboratory (ANCE), which tested products as part of the certification and enforcement mechanism defined by the standards program. Using this data, together with economic and market data provided by both government and private sector sources, the analysis considers several types of national level program impacts. These include: Energy savings; Environmental (emissions) impacts, and Net financial impacts to consumers, manufacturers and utilities. Energy savings impacts are calculated using the same methodology as the original projections, allowing a comparison. Other impacts are calculated using a robust and sophisticated methodology developed by the Instituto de Investigaciones Electricas (IIE) and Lawrence Berkeley National Laboratory (LBNL), in a collaboration supported by the Collaborative Labeling and Standards Program (CLASP).« less
Al Mortadi, Noor; Jones, Quentin; Eggbeer, Dominic; Lewis, Jeffrey; Williams, Robert J
2015-11-01
The aim of this study was to fabricate a resin appliance incorporating "wire" components without the use of an analog impression and dental casts using an intraoral scanner and computer technology to build the appliance. This unique alignment of technology offers an enormous reduction in the number of fabrication steps when compared with more traditional methods of manufacture. The prototype incorporated 2 Adams clasps and a fitted labial bow. The alloy components were built from cobalt-chromium in an initial powdered form using established digital technology methods and then inserted into a build of a resin base plate. This article reports the first known use of computer-aided design and additive manufacture to fabricate a resin and alloy appliance, and constitutes proof of the concept for such manufacturing. The original workflow described could be seen as an example for many other similar appliances, perhaps with active components. The scan data were imported into an appropriate specialized computer-aided design software, which was used in conjunction with a force feedback (haptic) interface. The appliance designs were then exported as stereolithography files and transferred to an additive manufacturing machine for fabrication. The results showed that the applied techniques may provide new manufacturing and design opportunities in orthodontics and highlights the need for intraoral-specific additive manufacture materials to be produced and tested for biocompatibility compliance. In a trial, the retainer was fitted orally and judged acceptable by the clinician according to the typical criteria when placing such appliances in situ. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
2015-01-01
This article reviews the topic of how to identify and develop a removable partial denture (RPD) path of placement, and provides a literature review of the concept of the RPD path of placement, also known as the path of insertion. An optimal RPD path of placement, guided by mutually parallel guide planes, ensures that the RPD flanges fit intimately over edentulous ridge structures and that the framework fits intimately with guide plane surfaces, which prevents food collecting empty spaces between the intaglio surface of the framework and intraoral surfaces, and ensures that RPD clasps engage adequate numbers of tooth undercuts to ensure RPD retention. The article covers topics such as the causes of obstructions to RPD intra-oral seating, the causes of food collecting empty spaces that may exist around an RPD, and how to identify if a guide plane is parallel with the projected RPD path of placement. The article presents a method of using a surgical operating microscope, or high magnification (6-8x or greater) binocular surgical loupes telescopes, combined with co-axial illumination, to identify a preliminary path of placement for an arch. This preliminary path of placement concept may help to guide a dentist or a dental laboratory technician when surveying a master cast of the arch to develop an RPD path of placement, or in verifying that intra-oral contouring has aligned teeth surfaces optimally with the RPD path of placement. In dentistry, a well-fitting RPD reduces long-term periodontal or structural damage to abutment teeth. PMID:25722842
Mating and aggregative behaviors among basal hexapods in the Early Cretaceous.
Sánchez-García, Alba; Peñalver, Enrique; Delclòs, Xavier; Engel, Michael S
2018-01-01
Among the many challenges in paleobiology is the inference and reconstruction of behaviors that rarely, if ever, leave a physical trace on the environment that is suitable for fossilization. Of particular significance are those behaviors tied to mating and courtship, individual interactions critical for species integrity and continuance, as well as those for dispersal, permitting the taxon to expand its distribution as well as access new habitats in the face of local or long-term environmental change. In this context, two recently discovered fossils from the Early Cretaceous amber of Spain (ca. 105 mya) give a detailed view of otherwise fleeting ethologies in Collembola. These occurrences are phylogenetically spaced across the class, and from species representing the two major clades of springtails-Symphypleona and Entomobryomorpha. Specifically, we report unique evidence from a symphypleonan male (Pseudosminthurides stoechus Sánchez-García & Engel, 2016) with modified antennae that may have functioned as a clasping organ for securing females during mating on water's surface, and from an aggregation of entomobryomorphan individuals (Proisotoma communis Sánchez-García & Engel, 2016) purportedly representing a swarming episode on the forest floor. We demonstrate that the mating behavioral repertoire in P. stoechus, which is associated with considerable morphological adaptations, likely implied elaborate courtship and maneuvering for guarantee sperm transfer in an epineustic species. These discoveries reveal significant behaviors consistent with modern counterparts and a generalized stasis for some ancient hexapod ethologies associated with complex mating and courtship and social or pre-social aggregations, so critical to specific constancy and dispersal.
Mating and aggregative behaviors among basal hexapods in the Early Cretaceous
Sánchez-García, Alba; Peñalver, Enrique; Delclòs, Xavier
2018-01-01
Among the many challenges in paleobiology is the inference and reconstruction of behaviors that rarely, if ever, leave a physical trace on the environment that is suitable for fossilization. Of particular significance are those behaviors tied to mating and courtship, individual interactions critical for species integrity and continuance, as well as those for dispersal, permitting the taxon to expand its distribution as well as access new habitats in the face of local or long-term environmental change. In this context, two recently discovered fossils from the Early Cretaceous amber of Spain (ca. 105 mya) give a detailed view of otherwise fleeting ethologies in Collembola. These occurrences are phylogenetically spaced across the class, and from species representing the two major clades of springtails—Symphypleona and Entomobryomorpha. Specifically, we report unique evidence from a symphypleonan male (Pseudosminthurides stoechus Sánchez-García & Engel, 2016) with modified antennae that may have functioned as a clasping organ for securing females during mating on water’s surface, and from an aggregation of entomobryomorphan individuals (Proisotoma communis Sánchez-García & Engel, 2016) purportedly representing a swarming episode on the forest floor. We demonstrate that the mating behavioral repertoire in P. stoechus, which is associated with considerable morphological adaptations, likely implied elaborate courtship and maneuvering for guarantee sperm transfer in an epineustic species. These discoveries reveal significant behaviors consistent with modern counterparts and a generalized stasis for some ancient hexapod ethologies associated with complex mating and courtship and social or pre-social aggregations, so critical to specific constancy and dispersal. PMID:29466382
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ishikawa, R.; Kubo, M.; Kano, R.
The Chromospheric Lyman-Alpha Spectro-Polarimeter is a sounding rocket experiment that has provided the first successful measurement of the linear polarization produced by scattering processes in the hydrogen Ly α line (121.57 nm) radiation of the solar disk. In this paper, we report that the Si iii line at 120.65 nm also shows scattering polarization and we compare the scattering polarization signals observed in the Ly α and Si iii lines in order to search for observational signatures of the Hanle effect. We focus on four selected bright structures and investigate how the U / I spatial variations vary between themore » Ly α wing, the Ly α core, and the Si iii line as a function of the total unsigned photospheric magnetic flux estimated from Solar Dynamics Observatory /Helioseismic and Magnetic Imager observations. In an internetwork region, the Ly α core shows an antisymmetric spatial variation across the selected bright structure, but it does not show it in other more magnetized regions. In the Si iii line, the spatial variation of U / I deviates from the above-mentioned antisymmetric shape as the total unsigned photospheric magnetic flux increases. A plausible explanation of this difference is the operation of the Hanle effect. We argue that diagnostic techniques based on the scattering polarization observed simultaneously in two spectral lines with very different sensitivities to the Hanle effect, like Ly α and Si iii, are of great potential interest for exploring the magnetism of the upper solar chromosphere and transition region.« less
Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNeil, Michael A.; Iyer, Maithili
The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standardsmore » in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption in each scenario, and associated electricity savings and carbon emission mitigation. Finally, financial costs and savings are scaled to the national level to evaluate net fiscal benefits.« less
Miller, B R; Dorner, J L; Shou, M; Sari, Y; Barton, S J; Sengelaub, D R; Kennedy, R T; Rebec, G V
2008-04-22
The striatum, which processes cortical information for behavioral output, is a key target of Huntington's disease (HD), an autosomal dominant condition characterized by cognitive decline and progressive loss of motor control. Increasing evidence implicates deficient glutamate uptake caused by a down-regulation of GLT1, the primary astroglial glutamate transporter. To test this hypothesis, we administered ceftriaxone, a beta-lactam antibiotic known to elevate GLT1 expression (200 mg/kg, i.p., for 5 days), to symptomatic R6/2 mice, a widely studied transgenic model of HD. Relative to vehicle, ceftriaxone attenuated several HD behavioral signs: paw clasping and twitching were reduced, while motor flexibility, as measured in a plus maze, and open-field climbing were increased. Assessment of GLT1 expression in striatum confirmed a ceftriaxone-induced increase relative to vehicle. To determine if the change in behavior and GLT1 expression represented a change in striatal glutamate handling, separate groups of behaving mice were evaluated with no-net-flux microdialysis. Vehicle treatment revealed a glutamate uptake deficit in R6/2 mice relative to wild-type controls that was reversed by ceftriaxone. Vehicle-treated animals, however, did not differ in GLT1 expression, suggesting that the glutamate uptake deficit in R6/2 mice reflects dysfunctional rather than missing GLT1. Our results indicate that impaired glutamate uptake is a major factor underlying HD pathophysiology and symptomology. The glutamate uptake deficit, moreover, is present in symptomatic HD mice and reversal of this deficit by up-regulating the functional expression of GLT1 with ceftriaxone attenuates the HD phenotype.
Adebola, Adijat A; Di Castri, Theo; He, Chui-Zhen; Salvatierra, Laura A; Zhao, Jian; Brown, Kristy; Lin, Chyuan-Sheng; Worman, Howard J; Liem, Ronald K H
2015-04-15
Charcot-Marie-Tooth disease (CMT) is the most commonly inherited neurological disorder with a prevalence of 1 in 2500 people worldwide. Patients suffer from degeneration of the peripheral nerves that control sensory information of the foot/leg and hand/arm. Multiple mutations in the neurofilament light polypeptide gene, NEFL, cause CMT2E. Previous studies in transfected cells showed that expression of disease-associated neurofilament light chain variants results in abnormal intermediate filament networks associated with defects in axonal transport. We have now generated knock-in mice with two different point mutations in Nefl: P8R that has been reported in multiple families with variable age of onset and N98S that has been described as an early-onset, sporadic mutation in multiple individuals. Nefl(P8R/+) and Nefl(P8R/P8R) mice were indistinguishable from Nefl(+/+) in terms of behavioral phenotype. In contrast, Nefl(N98S/+) mice had a noticeable tremor, and most animals showed a hindlimb clasping phenotype. Immunohistochemical analysis revealed multiple inclusions in the cell bodies and proximal axons of spinal cord neurons, disorganized processes in the cerebellum and abnormal processes in the cerebral cortex and pons. Abnormal processes were observed as early as post-natal day 7. Electron microscopic analysis of sciatic nerves showed a reduction in the number of neurofilaments, an increase in the number of microtubules and a decrease in the axonal diameters. The Nefl(N98S/+) mice provide an excellent model to study the pathogenesis of CMT2E and should prove useful for testing potential therapies. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Peng, Yingjie; Zhong, Chen; Huang, Wei; Ding, Jianping
2008-09-01
Isocitrate dehydrogenases (IDHs) catalyze oxidative decarboxylation of isocitrate (ICT) into alpha-ketoglutarate (AKG). We report here the crystal structures of Saccharomyces cerevesiae mitochondrial NADP-IDH Idp1p in binary complexes with coenzyme NADP, or substrate ICT, or product AKG, and in a quaternary complex with NADPH, AKG, and Ca(2+), which represent different enzymatic states during the catalytic reaction. Analyses of these structures identify key residues involved in the binding of these ligands. Comparisons among these structures and with the previously reported structures of other NADP-IDHs reveal that eukaryotic NADP-IDHs undergo substantial conformational changes during the catalytic reaction. Binding or release of the ligands can cause significant conformational changes of the structural elements composing the active site, leading to rotation of the large domain relative to the small and clasp domains along two hinge regions (residues 118-124 and residues 284-287) while maintaining the integrity of its secondary structural elements, and thus, formation of at least three distinct overall conformations. Specifically, the enzyme adopts an open conformation when bound to NADP, a quasi-closed conformation when bound to ICT or AKG, and a fully closed conformation when bound to NADP, ICT, and Ca(2+) in the pseudo-Michaelis complex or with NADPH, AKG, and Ca(2+) in the product state. The conformational changes of eukaryotic NADP-IDHs are quite different from those of Escherichia coli NADP-IDH, for which significant conformational changes are observed only between two forms of the apo enzyme, suggesting that the catalytic mechanism of eukaryotic NADP-IDHs is more complex than that of EcIDH, and involves more fine-tuned conformational changes.
Perretta, Silvana; Dallemagne, Bernard; Donatelli, Gianfranco; Diemunsch, Pierre; Marescaux, Jacques
2011-01-01
The most effective treatment of achalasia is Heller myotomy. To explore a submucosal endoscopic myotomy technique tailored on esophageal physiology testing and to compare it with the open technique. Prospective acute and survival comparative study in pigs (n = 12; 35 kg). University animal research center. Eight acute-4 open and 4 endoscopic-myotomies followed by 4 survival endoscopic procedures. Preoperative and postoperative manometry; esophagogastric junction (EGJ) distensibility before and after selective division of muscular fibers at the EGJ and after the myotomy was prolonged to a standard length by using the EndoFLIP Functional Lumen Imaging Probe (Crospon, Galway, Ireland). All procedures were successful, with no intraoperative and postoperative complications. In the survival group, the animals recovered promptly from surgery. Postoperative manometry demonstrated a 50% drop in mean lower esophageal sphincter pressure (LESp) in the endoscopic group (mean preoperative LESp, 22.2 ± 3.3 mm Hg; mean postoperative LESp, 11.34 ± 2.7 mm Hg; P < .005) and a 69% loss in the open procedure group (mean preoperative LESp, 24.2 ± 3.2 mm Hg; mean postoperative LESp, 7.4 ± 4 mm Hg; P < .005). The EndoFLIP monitoring did not show any distensibility difference between the 2 techniques, with the main improvement occurring when the clasp circular fibers were taken. Healthy animal model; small sample. Endoscopic submucosal esophageal myotomy is feasible and safe. The lack of a significant difference in EGJ distensibility between the open and endoscopic procedure is very appealing. Were it to be perfected in a human population, this endoscopic approach could suggest a new strategy in the treatment of selected achalasia patients. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Neurotoxicity produced by dibromoacetic acid in drinking water of rats.
Moser, V C; Phillips, P M; Levine, A B; McDaniel, K L; Sills, R C; Jortner, B S; Butt, M T
2004-05-01
An evaluation of potential adverse human health effects of disinfection byproducts requires study of both cancer and noncancer endpoints; however, no studies have evaluated the neurotoxic potential of a common haloacetic acid, dibromoacetic acid (DBA). This study characterized the neurotoxicity of DBA during 6-month exposure in the drinking water of rats. Adolescent male and female Fischer 344 rats were administered DBA at 0, 0.2, 0.6, and 1.5 g/l. On a mg/kg/day basis, the consumed dosages decreased greatly over the exposure period, with average intakes of 0, 20, 72, and 161 mg/kg/day. Weight gain was depressed in the high-concentration group, and concentration-related diarrhea and hair loss were observed early in exposure. Testing with a functional observational battery and motor activity took place before dosing and at 1, 2, 4, and 6 months. DBA produced concentration-related neuromuscular toxicity (mid and high concentrations) characterized by limb weakness, mild gait abnormalities, and hypotonia, as well as sensorimotor depression (all concentrations), with decreased responses to a tail-pinch and click. Other signs of toxicity at the highest concentration included decreased activity and chest clasping. Neurotoxicity was evident as early as one month, but did not progress with continued exposure. The major neuropathological finding was degeneration of spinal cord nerve fibers (mid and high concentrations). Cellular vacuolization in spinal cord gray matter (mostly) and in white matter (occasionally) tracts was also observed. No treatment-related changes were seen in brain, eyes, peripheral nerves, or peripheral ganglia. The lowest-observable effect level for neurobehavioral changes was 20 mg/kg/day (produced by 0.2 g/l, lowest concentration tested), whereas this dosage was a no-effect level for neuropathological changes. These studies suggest that neurotoxicity should be considered in the overall hazard evaluation of haloacetic acids.
Tanimoto, Yasuhiro; Nagakura, Manamu; Nishiyama, Norihiro
2018-02-21
The purpose of this study was to investigate the combined effects of fiber loading and pigmentation on the color differences and flexural properties of glass fiber-reinforced thermoplastics (GFRTPs), for use in non-metal clasp dentures (NMCDs). The GFRTPs consisted mainly of E-glass fibers, a polypropylene matrix, and a coloring pigment: the GFRTPs with various fiber loadings (0, 10, and 20mass%) and pigmentations (0, 1, 2, and 4mass%) were fabricated by using an injection molding. The color differences of GFRTPs were measured based on the Commission Internationale de l'Eclairage (CIE) Lab color system, by comparing with a commercially available NMCD. The flexural properties of GFRTPs were evaluated by using a three-point bending test, according to International Standards Organization (ISO) specification number 20795-1. The visible colors of GFRTPs with pigment contents of 2mass% were acceptable for gingival color, and the glass fibers harmonized well with the resins. The ΔE* values of the GFRTPs with pigment contents of 2mass% obtained by using the CIE Lab system were lowest at all fiber loadings. For GFRTPs with fiber contents of 10 and 20mass% at 2mass% pigment content, these GFRTPs surpassed the ISO 20795-1 specification regarding flexural strength (> 60MPa) and modulus (> 1.5GPa). A combination of the results of color difference evaluation and mechanical examination indicates that the GFRTPs with fiber contents of 10 or 20mass%, and with pigment contents of 2mass% have acceptable esthetic appearance and sufficient rigidity for NMCDs. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
CLASP2: The Chromospheric LAyer Spectro-Polarimeter
NASA Technical Reports Server (NTRS)
Mckenzie, D. E.; Ishikawa, R.; Bueno, J. Trujillo; Auchere, F.; Rachmeler, L.; Kubo, M.; Kobayashi, K.; Winebarger, A.; Bethge, C.; Narukage, N.;
2017-01-01
A major remaining challenge for heliophysicsis to decipher the magnetic structure of the chromosphere, due to its "large role in defining how energy is transported into the corona and solar wind" (NASA's Heliophysics Roadmap). Recent observational advances enabled by the Interface Region Imaging Spectrometer (IRIS) have revolutionized our view of the critical role this highly dynamic interface between the photosphere and corona plays in energizing and structuring the outer solar atmosphere. Despite these advances, a major impediment to better understanding the solar atmosphere is our lack of empirical knowledge regarding the direction and strength of the magnetic field in the upper chromosphere. Such measurements are crucial to address several major unresolved issues in solar physics: for example, to constrain the energy flux carried by the Alfven waves propagating through the chromosphere (De Pontieuet al., 2014), and to determine the height at which the plasma Beta = 1 transition occurs, which has important consequences for the braiding of magnetic fields (Cirtainet al., 2013; Guerreiroet al., 2014), for propagation and mode conversion of waves (Tian et al., 2014a; Straus et al., 2008) and for non-linear force-free extrapolation methods that are key to determining what drives instabilities such as flares or coronal mass ejections (e.g.,De Rosa et al., 2009). The most reliable method used to determine the solar magnetic field vector is the observation and interpretation of polarization signals in spectral lines, associated with the Zeeman and Hanle effects. Magnetically sensitive ultraviolet spectral lines formed in the upper chromosphere and transition region provide a powerful tool with which to probe this key boundary region (e.g., Trujillo Bueno, 2014). Probing the magnetic nature of the chromosphere requires measurement of the Stokes I, Q, U and V profiles of the relevant spectral lines (of which Q, U and V encode the magnetic field information).
De Pace, Raffaella; Damme, Markus; Mattera, Rafael; Jarnik, Michal; Hoffmann, Victoria; Morris, H. Douglas; Han, Tae-Un; Mancini, Grazia M. S.; Buonanno, Andrés
2018-01-01
The hereditary spastic paraplegias (HSP) are a clinically and genetically heterogeneous group of disorders characterized by progressive lower limb spasticity. Mutations in subunits of the heterotetrameric (ε-β4-μ4-σ4) adaptor protein 4 (AP-4) complex cause an autosomal recessive form of complicated HSP referred to as “AP-4 deficiency syndrome”. In addition to lower limb spasticity, this syndrome features intellectual disability, microcephaly, seizures, thin corpus callosum and upper limb spasticity. The pathogenetic mechanism, however, remains poorly understood. Here we report the characterization of a knockout (KO) mouse for the AP4E1 gene encoding the ε subunit of AP-4. We find that AP-4 ε KO mice exhibit a range of neurological phenotypes, including hindlimb clasping, decreased motor coordination and weak grip strength. In addition, AP-4 ε KO mice display a thin corpus callosum and axonal swellings in various areas of the brain and spinal cord. Immunohistochemical analyses show that the transmembrane autophagy-related protein 9A (ATG9A) is more concentrated in the trans-Golgi network (TGN) and depleted from the peripheral cytoplasm both in skin fibroblasts from patients with mutations in the μ4 subunit of AP-4 and in various neuronal types in AP-4 ε KO mice. ATG9A mislocalization is associated with increased tendency to accumulate mutant huntingtin (HTT) aggregates in the axons of AP-4 ε KO neurons. These findings indicate that the AP-4 ε KO mouse is a suitable animal model for AP-4 deficiency syndrome, and that defective mobilization of ATG9A from the TGN and impaired autophagic degradation of protein aggregates might contribute to neuroaxonal dystrophy in this disorder. PMID:29698489
Macedo-Júnior, Sérgio José; Luiz-Cerutti, Murilo; Nascimento, Denise B; Farina, Marcelo; Soares Santos, Adair Roberto; de Azevedo Maia, Alcíbia Helena
2017-01-01
Various studies on methylmercury (MeHg)-induced toxicity focused on the central nervous system (CNS) as a primary target. However, MeHg-mediated toxicity is related to metallic interaction with electrophilic groups, which are not solely restricted to the CNS, but these reactive groups are present ubiquitously in several systems/organs. The aim of this study was thus to examine MeHg-induced systemic toxicity in mice using a standardized neurotoxicology testing exposure model to measure cerebellar neurotoxicity by determining biochemical and behavioral parameters in the cerebellum. After 2 weeks exposure to MeHg (40 µg/ml; diluted in drinking water; ad libitum), adult male Swiss mice showed a marked motor impairment characteristic of cerebellar toxicity as noted in the following tests: rotarod, beam walking, pole, and hind limb clasping. MeHg treatment resulted in Hg deposition in the cerebellum as well as reduction in cerebellar weight, glutathione peroxidase (GPx) activity, and interleukin (IL)-6 levels. MeHg ingestion increased cerebellar glutathione reductase (GR) activity and brain-derived neurotrophic factor (BDNF) levels. In addition to cerebellar toxicity, MeHg treatment also elevated total and non-high density lipoprotein (non-HDL) cholesterol levels, as well as serum aspartate transaminase (AST) and alanine transaminase (ALT) enzymatic activities, systemic parameters. Increased liver weight and reduced serum urea levels were also noted in MeHg-exposed mice. Taken together, our findings demonstrated that a well-standardized exposure protocol to examine MeHg-induced neurotoxicity also produced systemic toxicity in mice, which was characterized by changes in markers of hepatic function as well as serum lipid homeostasis.
Clarkson, Edward D; Schulz, Susan M; Railer, Roy F; Smith, Kelly H
2012-08-03
Soman (GD) and VX are chemical warfare agents that can be absorbed through the skin. We determined the median lethal dose (MLD) for the cutaneous application of GD and VX in anesthetized haired guinea pigs and then tested the ability of a currently fielded decontamination kit, the M291 Skin Decontamination Kit (SDK), and decontaminating foam made by SANDIA Labs to decontaminate areas that have been exposed to cutaneous applications of GD and VX. The fur of guinea pigs was clipped on the left flank 24h prior to exposure. Animals were anesthetized and 5 min later neat GD or neat VX was applied. The MLD for percutaneous exposure to GD was 11.6 mg/kg, and to VX it was 0.10mg/kg. To test the ability of the M291 SDK, either GD or VX was applied and removed 1 min later with the pads of the M291 SDK clasped in a pair of forceps and wiped across the flank of the animal. The MLDs for GD and VX removed with the M291 SDK pads were 76.9 mg/kg and 0.87 mg/kg, respectively. When neat GD or neat VX was applied and removed 1 min later in the same manner with gauze soaked in SANDIA foam (MDF-100), the MLDs were 412 mg/kg and 10.4 mg/kg respectively. These data demonstrate that GD and VX are significantly less potent when applied cutaneously than previously reported for subcutaneous injections and indicate that improvement is needed on the limited protective ratio provided by the M291 SDK. Published by Elsevier Ireland Ltd.
Kocyła, Anna; Adamczyk, Justyna; Krężel, Artur
2018-01-24
Cellular zinc (Zn(ii)) is bound with proteins that are part of the proteomes of all domains of life. It is mostly utilized as a catalytic or structural protein cofactor, which results in a vast number of binding architectures. The Zn(ii) ion is also important for the formation of transient protein complexes with a Zn(ii)-dependent quaternary structure that is formed upon cellular zinc signals. The mechanisms by which proteins associate with and dissociate from Zn(ii) and the connection with cellular Zn(ii) changes remain incompletely understood. In this study, we aimed to examine how zinc protein domains with various Zn(ii)-binding architectures are formed under free Zn(ii) concentration changes and how formation of the Zn(ii)-dependent assemblies is related to the protein concentration and reactivity. To accomplish these goals we chose four zinc domains with different Zn(ii)-to-protein binding stoichiometries: classical zinc finger (ZnP), LIM domain (Zn 2 P), zinc hook (ZnP 2 ) and zinc clasp (ZnP 1 P 2 ) folds. Our research demonstrated a lack of changes in the saturation level of intraprotein zinc binding sites, despite various peptide concentrations, while homo- and heterodimers indicated a concentration-dependent tendency. In other words, at a certain free Zn(ii) concentration, the fraction of a formed dimeric complex increases or decreases with subunit concentration changes. Secondly, even small or local changes in free Zn(ii) may significantly affect protein saturation depending on its architecture, function and subcellular concentration. In our paper, we indicate the importance of interdependence of free Zn(ii) availability and protein subunit concentrations for cellular zinc signal regulation.
CLASP2: The Chromospheric LAyer Spectro-Polarimeter
NASA Technical Reports Server (NTRS)
McKenzie, D. E.; Ishikawa, R.; Bueno, J. Trujillo; Auchere, F.; Rachmeler, L; Kudo, M.; Kobayashi, K.; Winebarger, A.; Bethge, C.; Narukage, N.;
2017-01-01
A major remaining challenge for heliophysicsis to decipher the magnetic structure of the chromosphere, due to its 'large role in defining how energy is transported into the corona and solar wind' (NASA's Heliophysics Roadmap). Recent observational advances enabled by the Interface Region Imaging Spectrometer (IRIS) have revolutionized our view of the critical role this highly dynamic interface between the photosphere and corona plays in energizing and structuring the outer solar atmosphere. Despite these advances, a major impediment to better understanding the solar atmosphere is our lack of empirical knowledge regarding the direction and strength of the magnetic field in the upper chromosphere. Such measurements are crucial to address several major unresolved issues in solar physics: for example, to constrain the energy flux carried by the Alfven waves propagating through the chromosphere (De Pontieuet al., 2014), and to determine the height at which the plasma ß = 1 transition occurs, which has important consequences for the braiding of magnetic fields (Cirtainet al., 2013; Guerreiroet al., 2014), for propagation and mode conversion of waves (Tian et al., 2014a; Straus et al., 2008) and for non-linear force-free extrapolation methods that are key to determining what drives instabilities such as flares or coronal mass ejections (e.g., De Rosa et al., 2009). The most reliable method used to determine the solar magnetic field vector is the observation and interpretation of polarization signals in spectral lines, associated with the Zeeman and Hanle effects. Magnetically sensitive ultraviolet spectral lines formed in the upper chromosphere and transition region provide a powerful tool with which to probe this key boundary region (e.g., Trujillo Bueno, 2014). Probing the magnetic nature of the chromosphere requires measurement of the Stokes I, Q, U and V profiles of the relevant spectral lines (of which Q, U and V encode the magnetic field information).
DIETARY SELENIUM PROTECTS AGAINST SELECTED SIGNS OF AGING AND METHYLMERCURY EXPOSURE
Banna, Kelly M.; Reed, Miranda N.; Pesek, Erin F.; Cole, Nathan; Li, Jun; Newland, M. Christopher
2010-01-01
Acute or short-term exposure to high doses of methylmercury (MeHg) causes a well-characterized syndrome that includes sensory and motor deficits. The environmental threat from MeHg, however, comes from chronic, low-level exposure, the consequences of which are poorly understood. Selenium (Se), an essential nutrient, both increases deposition of mercury (Hg) in neurons and mitigates some of MeHg's neurotoxicity in the short term, but it is unclear whether this deposition produces long-term adverse consequences. To investigate these issues, adult Long Evans rats were fed a diet containing 0.06 or 0.6 ppm of Se as sodium selenite. After 100 days on these diets, the subjects began consuming 0.0, 0.5, 5.0, or 15 ppm of Hg as methylmercuric chloride in their drinking water for 16 months. Somatosensory sensitivity, grip strength, hind-limb cross (clasping reflex), flexion, and voluntary wheel-running in overnight sessions were among the measures examined. MeHg caused a dose- and time-dependent impairment in all measures, No effects appeared in rats consuming 0 or 0.5 ppm of Hg. Somatosensory function, grip strength, and flexion were among the earliest signs of exposure. Selenium significantly delayed or blunted MeHgs effects. Selenium also increased running in unexposed animals as they aged, a novel finding that may have important clinical implications. Nerve pathology studies revealed axonal atrophy or mild degeneration in peripheral nerve fibers, which is consistent with abnormal sensorimotor function in chronic MeHg neurotoxicity. Lidocaine challenge reproduced the somatosensory deficits but not hind-limb cross or flexion. Together, these results quantify the neurotoxicity of long-term MeHg exposure, support the safety and efficacy of Se in ameliorating MeHg's neurotoxicity, and demonstrate the potential benefits of Se during aging. PMID:20079371
Dula, Linda J.; Shala, Kujtim Sh.; Pustina–Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F.
2015-01-01
Objective: The aim of this study was to evaluate the influence of removable partial dentures (RPD) on the periodontal health of abutment and non-abutment teeth. Materials and Methods: A total 107 patients with RPD participated in this study. It was examined 138 RPD, they were 87 with clasp-retained and 51 were RPD with attachments. The following periodontal parameters were evaluated for abutment and non-abutment teeth, plaque index (PLI), calculus index (CI), bleeding on probing (BOP), probing depth (PD) (mm) and tooth mobility (TM) index. These clinical measurements were taken immediately before insertion the RPD, then one and 3 months after insertion. The level of significance was set at (P < 0.05). Results: The mean scores for PLI, CI, BOP, PD, and TM index, of the abutment teeth and non-abutment teeth were no statistically significant at the time of insertion of RPD. After 1-month, PLI was statistically significant (0.57 ± 0.55 for abutment and 0.30 ± 0.46 for non-abutment teeth). After 3 months, there were significant differences between abutment and non-abutment teeth with regard to the BOP (1.53 ± 0.50 and 1.76 ± 0.43 respectively), PD (0.28 ± 0.45 and 0.12 ± 0.33 respectively) and PLI (1.20 ± 0.46 and 0.75 ± 0.64 respectively). No significant mean difference in TM and CI was found between the abutment and non-abutment teeth (P > 0.05). Conclusions: With carefully planned prosthetic treatment and adequate maintenance of the oral and denture hygiene, we can prevent the periodontal diseases. PMID:26430367
Mackay, Bev; Harding, Thomas; Jurlina, Lou; Scobie, Norma; Khan, Ruelle
2012-03-01
The rising number of international students studying outside their own country poses challenges for nursing education. Numbers are predicted to grow and economic factors are placing increasing pressure on tertiary institutions to accept these students. In adapting to a foreign learning environment international students must not only adapt to the academic culture but also to the social cultural context. The most significant acculturation issues for students are English as a second language, differences in education pedagogy and social integration and connectedness. Students studying in New Zealand need to work with Māori, the indigenous people, and assimilate and practice the unique aspects of cultural safety, which has evolved in nursing as part of the response to the principles underpinning the Treaty of Waitangi. The Hand Model offers the potential to support international nursing students in a culturally safe manner across all aspects of acculturation including those aspects of cultural safety unique to New Zealand. The model was originally developed by Lou Jurlina, a nursing teacher, to assist her to teach cultural safety and support her students in practising cultural safety in nursing. The thumb, represents 'awareness', with the other four digits signifying 'connection', 'communication', 'negotiation' and 'advocacy' respectively. Each digit is connected to the palm where the ultimate evaluation of The Hand Model in promoting cultural safety culminates in the clasping and shaking of hands: the moment of shared meaning. It promotes a sense of self worth and identity in students and a safe environment in which they can learn. Copyright © 2011 Nursing Praxis in New Zealand. Published by Elsevier Ltd.. All rights reserved.
Vaisey, George; Miller, Alexandria N; Long, Stephen B
2016-11-22
Cytoplasmic calcium (Ca 2+ ) activates the bestrophin anion channel, allowing chloride ions to flow down their electrochemical gradient. Mutations in bestrophin 1 (BEST1) cause macular degenerative disorders. Previously, we determined an X-ray structure of chicken BEST1 that revealed the architecture of the channel. Here, we present electrophysiological studies of purified wild-type and mutant BEST1 channels and an X-ray structure of a Ca 2+ -independent mutant. From these experiments, we identify regions of BEST1 responsible for Ca 2+ activation and ion selectivity. A "Ca 2+ clasp" within the channel's intracellular region acts as a sensor of cytoplasmic Ca 2+ . Alanine substitutions within a hydrophobic "neck" of the pore, which widen it, cause the channel to be constitutively active, irrespective of Ca 2+ . We conclude that the primary function of the neck is as a "gate" that controls chloride permeation in a Ca 2+ -dependent manner. In contrast to what others have proposed, we find that the neck is not a major contributor to the channel's ion selectivity. We find that mutation of a cytosolic "aperture" of the pore does not perturb the Ca 2+ dependence of the channel or its preference for anions over cations, but its mutation dramatically alters relative permeabilities among anions. The data suggest that the aperture functions as a size-selective filter that permits the passage of small entities such as partially dehydrated chloride ions while excluding larger molecules such as amino acids. Thus, unlike ion channels that have a single "selectivity filter," in bestrophin, distinct regions of the pore govern anion-vs.-cation selectivity and the relative permeabilities among anions.
McDonnell, Diana D; Levy, Vivian; Morton, Theresa J M
2009-02-01
Chlamydia infections are increasing in California, with rates highest in young women aged 15 to 24. Juvenile detention facilities are important venues for screening high-risk youth who may not otherwise access care. We, therefore, sought to identify risk factors for urogenital chlamydia among young women in a county juvenile detention facility between 2002 and 2005. With the state Chlamydia Screening Project (ClaSP), young women booked into the county detention facility were offered urine-based screening for urogenital chlamydia. Demographics, sexual history, and behavioral risk factors were self-reported through questionnaires completed during specimen collection. Nine hundred and thirty-nine young women were screened for chlamydia. The 5% positivity rate remained steady over the 33-month study. Vaginal sex was reported by 82% of women, oral sex by 50%, and anal sex by 30%. Only 9% reporting anal sex always used condoms. In multivariate analysis, little distinguished those with urogenital chlamydia. Women from the southern region of the county (adjusted odds ratio, 3.5; 1.4-8.7) and surrounding urban centers (3.7; 1.2-11.4) had higher odds of infection, as did those with 2 to 3 lifetime partners (3.2; 1.2-8.2)-although there was no linear relationship between partner number and infection. Those who had been in drug/alcohol treatment had lower odds of infection (0.1; 0.01-0.6). Our findings support universal chlamydia testing of young women detainees. The high prevalence of unprotected anal sex highlights an important modifiable HIV risk behavior in these adolescents. Risk factors reported here should inform the integration of prevention and treatment services in correctional settings and substance abuse treatment centers.
Peng, Yingjie; Zhong, Chen; Huang, Wei; Ding, Jianping
2008-01-01
Isocitrate dehydrogenases (IDHs) catalyze oxidative decarboxylation of isocitrate (ICT) into α-ketoglutarate (AKG). We report here the crystal structures of Saccharomyces cerevesiae mitochondrial NADP-IDH Idp1p in binary complexes with coenzyme NADP, or substrate ICT, or product AKG, and in a quaternary complex with NADPH, AKG, and Ca2+, which represent different enzymatic states during the catalytic reaction. Analyses of these structures identify key residues involved in the binding of these ligands. Comparisons among these structures and with the previously reported structures of other NADP-IDHs reveal that eukaryotic NADP-IDHs undergo substantial conformational changes during the catalytic reaction. Binding or release of the ligands can cause significant conformational changes of the structural elements composing the active site, leading to rotation of the large domain relative to the small and clasp domains along two hinge regions (residues 118–124 and residues 284–287) while maintaining the integrity of its secondary structural elements, and thus, formation of at least three distinct overall conformations. Specifically, the enzyme adopts an open conformation when bound to NADP, a quasi-closed conformation when bound to ICT or AKG, and a fully closed conformation when bound to NADP, ICT, and Ca2+ in the pseudo-Michaelis complex or with NADPH, AKG, and Ca2+ in the product state. The conformational changes of eukaryotic NADP-IDHs are quite different from those of Escherichia coli NADP-IDH, for which significant conformational changes are observed only between two forms of the apo enzyme, suggesting that the catalytic mechanism of eukaryotic NADP-IDHs is more complex than that of EcIDH, and involves more fine-tuned conformational changes. PMID:18552125
NASA Tech Briefs, September 2013
NASA Technical Reports Server (NTRS)
2013-01-01
Topics include: ISS Ammonia Leak Detection Through X-Ray Fluorescence; A System for Measuring the Sway of the Vehicle Assembly Building; Fast, High-Precision Readout Circuit for Detector Arrays; Victim Simulator for Victim Detection Radar; Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot; Quasi-Linear Circuit; High-Speed, High-Resolution Time-to-Digital Conversion; Li-Ion Battery and Supercapacitor Hybrid Design for Long Extravehicular Activities; Ultrasonic Low-Friction Containment Plate for Thermal and Ultrasonic Stir Weld Processes; High-Powered, Ultrasonically Assisted Thermal Stir Welding; Next-Generation MKIII Lightweight HUT/Hatch Assembly; Centrifugal Sieve for Gravity-Level-Independent Size; Segregation of Granular Materials; Ion Exchange Technology Development in Support of the Urine Processor Assembly; Nickel-Graphite Composite Compliant Interface and/or Hot Shoe Material; UltraSail CubeSat Solar Sail Flight Experiment; Mechanism for Deploying a Long, Thin-Film Antenna From a Rover; Counterflow Regolith Heat Exchanger; Acquisition and Retaining Granular Samples via a Rotating Coring Bit; Very-Low-Cost, Rugged Vacuum System; Medicine Delivery Device With Integrated Sterilization and Detection; FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D; Multimode Directional Coupler for Utilization of Harmonic Frequencies from TWTAs; Dual-Polarization, Multi-Frequency Antenna Array for use with Hurricane Imaging Radiometer; Complementary Barrier Infrared Detector (CBIRD) Contact Methods; Autonomous Control of Space Nuclear Reactors; High-Power, High-Speed Electro-Optic Pockels Cell Modulator; Covariance Analysis Tool (G-CAT) for Computing Ascent, Descent, and Landing Errors; Enigma Version 12; Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program; Spitzer Telemetry Processing System; Planetary Protection Bioburden Analysis Program; Wing Leading Edge RCC Rapid Response Damage Prediction Tool (IMPACT2); ISSM: Ice Sheet System Model; Automated Loads Analysis System (ATLAS); Integrated Main Propulsion System Performance Reconstruction Process/Models. Phoenix Telemetry Processor; Contact Graph Routing Enhancements Developed in ION for DTN; GFEChutes Lo-Fi; Advanced Strategic and Tactical Relay Request Management for the Mars Relay Operations Service; Software for Generating Troposphere Corrections for InSAR Using GPS and Weather Model Data; Ionospheric Specifications for SAR Interferometry (ISSI); Implementation of a Wavefront-Sensing Algorithm; Sally Ride EarthKAM - Automated Image Geo-Referencing Using Google Earth Web Plug-In; Trade Space Specification Tool (TSST) for Rapid Mission Architecture (Version 1.2); Acoustic Emission Analysis Applet (AEAA) Software; Memory-Efficient Onboard Rock Segmentation; Advanced Multimission Operations System (ATMO); Robot Sequencing and Visualization Program (RSVP); Automating Hyperspectral Data for Rapid Response in Volcanic Emergencies; Raster-Based Approach to Solar Pressure Modeling; Space Images for NASA JPL Android Version; Kinect Engineering with Learning (KEWL); Spacecraft 3D Augmented Reality Mobile App; MPST Software: grl_pef_check; Real-Time Multimission Event Notification System for Mars Relay; SIM_EXPLORE: Software for Directed Exploration of Complex Systems; Mobile Timekeeping Application Built on Reverse-Engineered JPL Infrastructure; Advanced Query and Data Mining Capabilities for MaROS; Jettison Engineering Trajectory Tool; MPST Software: grl_suppdoc; PredGuid+A: Orion Entry Guidance Modified for Aerocapture; Planning Coverage Campaigns for Mission Design and Analysis: CLASP for DESDynl; and Space Place Prime.
Redolfi, Alberto; Manset, David; Barkhof, Frederik; Wahlund, Lars-Olof; Glatard, Tristan; Mangin, Jean-François; Frisoni, Giovanni B.
2015-01-01
Background and Purpose The measurement of cortical shrinkage is a candidate marker of disease progression in Alzheimer’s. This study evaluated the performance of two pipelines: Civet-CLASP (v1.1.9) and Freesurfer (v5.3.0). Methods Images from 185 ADNI1 cases (69 elderly controls (CTR), 37 stable MCI (sMCI), 27 progressive MCI (pMCI), and 52 Alzheimer (AD) patients) scanned at baseline, month 12, and month 24 were processed using the two pipelines and two interconnected e-infrastructures: neuGRID (https://neugrid4you.eu) and VIP (http://vip.creatis.insa-lyon.fr). The vertex-by-vertex cross-algorithm comparison was made possible applying the 3D gradient vector flow (GVF) and closest point search (CPS) techniques. Results The cortical thickness measured with Freesurfer was systematically lower by one third if compared to Civet’s. Cross-sectionally, Freesurfer’s effect size was significantly different in the posterior division of the temporal fusiform cortex. Both pipelines were weakly or mildly correlated with the Mini Mental State Examination score (MMSE) and the hippocampal volumetry. Civet differed significantly from Freesurfer in large frontal, parietal, temporal and occipital regions (p<0.05). In a discriminant analysis with cortical ROIs having effect size larger than 0.8, both pipelines gave no significant differences in area under the curve (AUC). Longitudinally, effect sizes were not significantly different in any of the 28 ROIs tested. Both pipelines weakly correlated with MMSE decay, showing no significant differences. Freesurfer mildly correlated with hippocampal thinning rate and differed in the supramarginal gyrus, temporal gyrus, and in the lateral occipital cortex compared to Civet (p<0.05). In a discriminant analysis with ROIs having effect size larger than 0.6, both pipelines yielded no significant differences in the AUC. Conclusions Civet appears slightly more sensitive to the typical AD atrophic pattern at the MCI stage, but both pipelines can accurately characterize the topography of cortical thinning at the dementia stage. PMID:25781983
Sigvardt, Zandra M. S.; Olesen, Jørgen
2014-01-01
Clam shrimps are freshwater branchiopod crustaceans which often present complicated breeding systems including asexual reproduction (parthenogenesis) and mixed mating systems (in androdioecious species both selfing and outcrossing occurs due to the co-presence of hermaphrodites and males). Reproductive patterns of Spinicaudata, which contains most clam shrimp species, have received much attention. Another group of clam shrimps, Laevicaudata, which holds a key position in branchiopod phylogeny, has practically not been studied. As a part of the mating process, males clasp to the carapace margin of the females with a pair (or two pairs) of anterior trunk limbs modified as claspers. Previous studies have shown that clasper morphology is important in a phylogenetic context, and that some parts of the claspers in Spinicaudata and Laevicaudata may have undergone a remarkable parallel evolution. Here we have used video microscopy to study aspects of the mating behaviour, egg extrusion, and fertilization in Lynceus brachyurus (Laevicaudata). It is shown that fertilization is likely to be external and that the peculiar tri-lobed lateral lamellae of female's hind body assist in guiding the egg mass to the exopodal egg carriers where they are collected by their distal setation. The functional morphology of the male claspers was studied in detail by close-up video recordings. The movable “finger” of the clasper bends around the female's carapace edge and serves to hold the female during mating. The larger palp grasps around the female carapace margin in a way very similar to the movable “finger”, possibly indirectly providing sensory input on the “finger” position. A brief comparative study of the claspers of a spinicaudatan clam shrimp showed both similarities and differences to the laevicaudatan claspers. The presence of two pairs of claspers in Spinicaudata seems to give males a better hold of the female which may play a role during extended mate guarding. PMID:24392104
Alternative role of HuD splicing variants in neuronal differentiation.
Hayashi, Satoru; Yano, Masato; Igarashi, Mana; Okano, Hirotaka James; Okano, Hideyuki
2015-03-01
HuD is a neuronal RNA-binding protein that plays an important role in neuronal differentiation of the nervous system. HuD has been reported to have three RNA recognition motifs (RRMs) and three splice variants (SVs) that differ in their amino acid sequences between RRM2 and RRM3. This study investigates whether these SVs have specific roles in neuronal differentiation. In primary neural epithelial cells under differentiating conditions, HuD splice variant 1 (HuD-sv1), which is a general form, and HuD-sv2 were expressed at all tested times, whereas HuD-sv4 was transiently expressed at the beginning of differentiation, indicating that HuD-sv4 might play a role compared different from that of HuD-sv1. Indeed, HuD-sv4 did not promote neuronal differentiation in epithelial cells, whereas HuD-sv1 did promote neuronal differentiation. HuD-sv4 overexpression showed less neurite-inducing activity than HuD-sv1 in mouse neuroblastoma N1E-115 cells; however, HuD-sv4 showed stronger growth-arresting activity. HuD-sv1 was localized only in the cytoplasm, whereas HuD-sv4 was localized in both the cytoplasm and the nuclei. The Hu protein has been reported to be involved in translation and alternative splicing in the cytoplasm and nuclei, respectively. Consistent with this observation, HuD-sv1 showed translational activity on p21, which plays a role in growth arrest and neuronal differentiation, whereas HuD-sv4 did not. By contrast, HuD-sv4 showed stronger pre-mRNA splicing activity than did HuD-sv1 on Clasp2, which participates in cell division. Therefore, HuD SVs might play a role in controlling the timing of proliferation/differentiation switching by controlling the translation and alternative splicing of target genes. © 2014 Wiley Periodicals, Inc.
Tonic vibration reflex in spasticity, Parkinson's disease, and normal subjects
Burke, David; Andrews, Colin J.; Lance, James W.
1972-01-01
The tonic vibration reflex (TVR) has been studied in the quadriceps and triceps surae muscles of 34 spastic, 15 Parkinsonism, and 10 normal subjects. The TVR of spasticity develops rapidly, reaching a plateau level within 2-4 sec of the onset of vibration. The tonic contraction was often preceded by a phasic spike which appeared to be a vibration-induced equivalent of the tendon jerk. The initial phasic spike was usually followed by a silent period, and induced clonus in some patients. No correlation was found between the shape of the TVR and the site of the lesion in the central nervous system. The TVR of normal subjects and patients with Parkinsonism developed slowly, starting some seconds after the onset of vibration, and reaching a plateau level in 20-60 sec. A phasic spike was recorded occasionally in these subjects, but the subsequent tonic contraction followed the usual time course. Muscle stretch increased the quadriceps TVR of all subjects, including those with spasticity in whom the quadriceps stretch reflex decreased with increasing stretch. It is suggested that this difference between the tonic vibration reflex and the tonic stretch reflex arises from the selective activation of spindle primary endings by vibration, while both the primary and the secondary endings are responsive to muscle stretch. The TVR could be potentiated by reinforcement in some subjects. Potentiation outlasted the reinforcing manoeuvre, and was most apparent at short muscle lengths. As muscle stretch increased, thus producing a larger TVR, the degree of potentiation decreased. It is therefore suggested that the effects of reinforcement result at least partially from the activation of the fusimotor system. Since reinforcement potentiated the TVR of patients with spinal spasticity in whom a prominent clasp-knife phenomenon could be demonstrated, it is suggested that the effects of reinforcement are mediated by a descending pathway that traverses the anterior quadrant of the spinal cord. PMID:4261955
Fuxe, Kjell; Borroto-Escuela, Dasiel O; Tarakanov, Alexander O; Romero-Fernandez, Wilber; Ferraro, Luca; Tanganelli, Sergio; Perez-Alea, Mileidys; Di Palma, Michael; Agnati, Luigi F
2014-01-01
This review is focused on the D2 heteroreceptor complexes within the ventral striatum with their receptor-receptor interactions and relevance for the treatment of schizophrenia. A "guide-and-clasp" manner for receptor-receptor interactions is proposed where "adhesive guides" may be amino acid triplet homologies, which were determined for different kinds of D2 heteroreceptor complexes. The first putative D2 heteroreceptor complex to be discovered in relation to schizophrenia was the A2A-D2 heteroreceptor complex where antagonistic A2A-D2 receptor-receptor interactions were demonstrated after A2A agonist treatment in the ventral striatum. The A2A agonist CGS 21680 with atypical antipsychotic properties may at least in part act by increasing β-arrestin2 signaling over the D2 protomer in the A2A-D2 heteroreceptor complex in the ventral striatum. The antagonistic NTS1-D2 interactions in the NTS1-D2 heteroreceptor complex in the ventral striatum are proposed as one molecular mechanism for the potential antipsychotic effects of NT. Indications were obtained that the psychotic actions of the 5-HT2AR hallucinogens LSD and DOI can involve enhancement of D2R protomer signaling via a biased agonist action at the 5-HT2A protomer in the D2-5-HT2A heteroreceptor complex in the ventral striatum. Facilitatory allosteric D2likeR-OTR interactions in heteroreceptor complexes in nucleus accumbens may have a role in social and emotional behaviors. By blocking the D2 protomers of these heteroreceptor complexes, antipsychotics can fail to reduce the negative symptoms of schizophrenia. The discovery of different types of D2 heteroreceptor complexes gives an increased understanding of molecular mechanisms involved in causing schizophrenia and new strategies for its treatment and understanding the side effects of antipsychotics. © 2014 Elsevier B.V. All rights reserved.
Sigvardt, Zandra M S; Olesen, Jørgen
2014-01-01
Clam shrimps are freshwater branchiopod crustaceans which often present complicated breeding systems including asexual reproduction (parthenogenesis) and mixed mating systems (in androdioecious species both selfing and outcrossing occurs due to the co-presence of hermaphrodites and males). Reproductive patterns of Spinicaudata, which contains most clam shrimp species, have received much attention. Another group of clam shrimps, Laevicaudata, which holds a key position in branchiopod phylogeny, has practically not been studied. As a part of the mating process, males clasp to the carapace margin of the females with a pair (or two pairs) of anterior trunk limbs modified as claspers. Previous studies have shown that clasper morphology is important in a phylogenetic context, and that some parts of the claspers in Spinicaudata and Laevicaudata may have undergone a remarkable parallel evolution. Here we have used video microscopy to study aspects of the mating behaviour, egg extrusion, and fertilization in Lynceus brachyurus (Laevicaudata). It is shown that fertilization is likely to be external and that the peculiar tri-lobed lateral lamellae of female's hind body assist in guiding the egg mass to the exopodal egg carriers where they are collected by their distal setation. The functional morphology of the male claspers was studied in detail by close-up video recordings. The movable "finger" of the clasper bends around the female's carapace edge and serves to hold the female during mating. The larger palp grasps around the female carapace margin in a way very similar to the movable "finger", possibly indirectly providing sensory input on the "finger" position. A brief comparative study of the claspers of a spinicaudatan clam shrimp showed both similarities and differences to the laevicaudatan claspers. The presence of two pairs of claspers in Spinicaudata seems to give males a better hold of the female which may play a role during extended mate guarding.
Alfieri, Julio A; Silva, Pablo R; Igaz, Lionel M
2016-01-01
Frontotemporal Dementia (FTD) and amyotrophic lateral sclerosis (ALS) are two neurodegenerative diseases associated to mislocalization and aggregation of TAR DNA-binding protein 43 (TDP-43). To investigate in depth the behavioral phenotype associated with this proteinopathy, we used as a model transgenic (Tg) mice conditionally overexpressing human wild-type TDP 43 protein (hTDP-43-WT) in forebrain neurons. We previously characterized these mice at the neuropathological level and found progressive neurodegeneration and other features that evoke human TDP-43 proteinopathies of the FTD/ALS spectrum. In the present study we analyzed the behavior of mice at multiple domains, including motor, social and cognitive performance. Our results indicate that young hTDP-43-WT Tg mice (1 month after post-weaning transgene induction) present a normal motor phenotype compared to control littermates, as assessed by accelerated rotarod performance, spontaneous locomotor activity in the open field test and a mild degree of spasticity shown by a clasping phenotype. Analysis of social and cognitive behavior showed a rapid installment of deficits in social interaction, working memory (Y-maze test) and recognition memory (novel object recognition test) in the absence of overt motor abnormalities. To investigate if the motor phenotype worsen with age, we analyzed the behavior of mice after long-term (up to 12 months) transgene induction. Our results reveal a decreased performance on the rotarod test and in the hanging wire test, indicating a motor phenotype that was absent in younger mice. In addition, long-term hTDP-43-WT expression led to hyperlocomotion in the open field test. In sum, these results demonstrate a time-dependent emergence of a motor phenotype in older hTDP-43-WT Tg mice, recapitulating aspects of clinical FTD presentations with motor involvement in human patients, and providing a complementary animal model for studying TDP-43 proteinopathies.
Yuskaitis, Christopher J; Jones, Brandon M; Wolfson, Rachel L; Super, Chloe E; Dhamne, Sameer C; Rotenberg, Alexander; Sabatini, David M; Sahin, Mustafa; Poduri, Annapurna
2018-03-01
DEPDC5 is a newly identified epilepsy-related gene implicated in focal epilepsy, brain malformations, and Sudden Unexplained Death in Epilepsy (SUDEP). In vitro, DEPDC5 negatively regulates amino acid sensing by the mTOR complex 1 (mTORC1) pathway, but the role of DEPDC5 in neurodevelopment and epilepsy has not been described. No animal model of DEPDC5-related epilepsy has recapitulated the neurological phenotypes seen in patients, and germline knockout rodent models are embryonic lethal. Here, we establish a neuron-specific Depdc5 conditional knockout mouse by cre-recombination under the Synapsin1 promotor. Depdc5 flox/flox -Syn1 Cre (Depdc5cc+) mice survive to adulthood with a progressive neurologic phenotype that includes motor abnormalities (i.e., hind limb clasping) and reduced survival compared to littermate control mice. Depdc5cc+ mice have larger brains with increased cortical neuron size and dysplastic neurons throughout the cortex, comparable to the abnormal neurons seen in human focal cortical dysplasia specimens. Depdc5 results in constitutive mTORC1 hyperactivation exclusively in neurons as measured by the increased phosphorylation of the downstream ribosomal protein S6. Despite a lack of increased mTORC1 signaling within astrocytes, Depdc5cc+ brains show reactive astrogliosis. We observed two Depdc5cc+ mice to have spontaneous seizures, including a terminal seizure. We demonstrate that as a group Depdc5cc+ mice have lowered seizure thresholds, as evidenced by decreased latency to seizures after chemoconvulsant injection and increased mortality from pentylenetetrazole-induced seizures. In summary, our neuron-specific Depdc5 knockout mouse model recapitulates clinical, pathological, and biochemical features of human DEPDC5-related epilepsy and brain malformations. We thereby present an important model in which to study targeted therapeutic strategies for DEPDC5-related conditions. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Letschert, Virginie E.; de la Rue du Can, Stephane; McNeil, Michael A.
This paper analyses several potential savings scenarios for minimum energy performance standard (MEPS) and comparable programs for governments participating i n the Super-efficient Equipment and Appliance Deployment (SEAD) Initiative, of the Clean Energy Ministerial, which represent over 60% of primary energy consumption in the world. We compare projected energy savings from the main end uses in the residential sector using three energy efficiency scenarios: (1) recent achievements, (2) cost-effective saving potential, and (3) energy efficiency technical potential. The recent achievement scenario (1) evaluates the future impact of MEPS enacted or under development between 2010 and 2012. The cost-effective potential scenariomore » (2) identifies the maximum potential for energy efficiency that results in net benefits to the consumer. The best available technology scenario (3) re presents the full potential of energy efficiency considering best available technologies as candidates for MEPS and incentive programs. We use the Bottom Up Energy Analysis System (BUENAS), developed by Lawrence Berkeley National Laboratory in collaboration with the Collaborative Labelling and Appliances Standards Program (CLASP), to provide a consistent methodology to com pare the different scenarios. This paper focuses on the main end uses in the residential sector. The comparison of the three scenarios for each economy provides possible opportunities for scaling up current policies or implementing additional policies. This comparison across economies reveals country best practices as well as end uses that present the greatest additional potential savings. The paper describes areas where methodologies and additional policy instruments can increase penetration of energy efficient technologies. First , we summarize the barriers and provide remedial policy tools/best practices, such as techno-economic analysis, in response to each barriers that prevent economies from capturing the full cost-effective potentials of MEPS (Scenario 1 to 2). Then, we consider the possible complementary policy options, such as incentive pro grams, to reach the full technical potential of energy efficiency in the residential sector (Scenario 2 to 3).« less
The Impact of the Crown-Root Ratio on Survival of Abutment Teeth for Dentures.
Tada, S; Allen, P F; Ikebe, K; Zheng, H; Shintani, A; Maeda, Y
2015-09-01
Crown-root ratio (CRR) is commonly recorded when planning prosthodontic procedures. However, there is a lack of longitudinal clinical data evaluating the association between CRR and tooth survival. The aim of this longitudinal practice-based study was to assess the impact of CRR on the survival of abutment teeth for removable partial dentures (RPDs). Data were collected from 147 patients provided with RPDs at a dental hospital in Japan. In total, 236 clasp-retained RPDs and 856 abutment teeth were analyzed. Survival of abutment teeth was assessed using Kaplan-Meier methods and Cox's proportional hazard (PH) regression. The Cox PH regression was used to assess the prognostic significance of initial CRR value with adjustments for clinically relevant factors, including age, sex, frequency of periodontal maintenance programs, occlusal support area, type of abutment tooth, status of endodontic treatment, and probing pocket depth. Abutment teeth were divided into 1 of 5 risk groups according to CRR: A (≤0.75), B (0.76-1.00), C (1.01-1.25), D (1.26-1.50) and E (≥1.51). The 7-year survival rate was 89.1% for group A, 85.9% for group B, 86.5% for group C, 76.9% for group D, and 46.7% for group E. The survival curves of groups A, B, and C were illustrated to be quite similar and favorable. The multivariable analysis treating CRR as a continuous variable allowed estimation of the hazard ratio at any specific CRR value. When CRR = 0.80 was set as a reference, the estimated hazard ratio was 0.58 for CRR = 0.50 (95% confidence interval [CI], 0.36-0.91), 1.13 for CRR = 1.00 (95% CI, 0.93-1.37), 1.35 for CRR = 1.25 (95% CI, 1.02-1.80), 1.53 for CRR = 1.50 (95% CI, 1.15-2.08), or 1.95 for CRR = 2.00 (95% CI, 1.44-2.65). These practice-based longitudinal data provide information to improve the evidence-based prognosis of teeth in providing prosthodontic procedures. © International & American Associations for Dental Research.
Two way controls of apoptotic regulators consign DmArgonaute-1 a better clasp on it
Bag, Indira; SNCVL, Pushpavalli; Garikapati, Koteswara Rao; Bhadra, Utpal
2018-01-01
Argonaute family proteins are well conserved among all organisms. Its role in mitotic cell cycle progression and apoptotic cell elimination is poorly understood. Earlier we have established the contribution of Ago-1 in cell cycle control related to G2/M cyclin in Drosophila. Here we have extended our study in understanding the relationship of Ago-1 in regulating apoptosis during Drosophila development. Apoptosis play a critical role in controlling organ shape and size during development of multi cellular organism. Multifarious regulatory pathways control apoptosis during development among which highly conserved JNK (c-Jun N-terminal kinase) pathway play a crucial role. Here we have over expressed Ago-1 in Drosophila eye and brain by employing UAS (upstream activation sequence)-GAL4 system under the expression of eye and brain specific driver. Over expression of Ago-1 resulted in reduced number of ommatidia in the eye and produced smaller size brain in adult and larval Drosophila. A drastic reversal of the phenotype towards normal was observed upon introduction of a single copy of the dominant negative mutation of basket (bsk, Drosophila homolog of JNK) indicating an active and physical involvement of the bsk with Ago-1 in inducing developmental apoptotic process. Further study showed that Ago-1 stimulates phosphorylation of JNK through transforming growth factor-β activated kinase 1- hemipterous (Tak1-hep) axis of JNK pathway. JNK phosphorylation results in up regulation of pro-apoptotic genes head involution defective (hid), grim & reaper (rpr) and induces activation of Drosophila caspases (cysteinyl aspartate proteinases);DRONC (Death regulator Nedd2-like caspase), ICE (alternatively Drice, Death related ICE-like caspase) and DCP1 (Death caspase-1) by inhibiting apoptotic inhibitor protein DIAP1 (Death-associated inhibitor of apoptosis 1). Further, Ago-1 also inhibits miR-14 expression to trigger apoptosis. Our findings propose that Ago-1 acts as a key regulator in controlling cell death, tumor regression and stress response in metazoan providing a constructive bridge between RNAi machinery and cell death. PMID:29385168
NASA Astrophysics Data System (ADS)
Schmid, Gernot; Hirtl, Rene
2016-06-01
The reference levels and maximum permissible exposure values for magnetic fields that are currently used have been derived from basic restrictions under the assumption of upright standing body models in a standard posture, i.e. with arms laterally down and without contact with metallic objects. Moreover, if anatomical modelling of the body was used at all, the skin was represented as a single homogeneous tissue layer. In the present paper we addressed the possible impacts of posture and skin modelling in scenarios of exposure to a 50 Hz uniform magnetic field on the in situ electric field strength in peripheral tissues, which must be limited in order to avoid peripheral nerve stimulation. We considered different body postures including situations where body parts form large induction loops (e.g. clasped hands) with skin-to-skin and skin-to-metal contact spots and compared the results obtained with a homogeneous single-layer skin model to results obtained with a more realistic two-layer skin representation consisting of a low-conductivity stratum corneum layer on top of a combined layer for the cellular epidermis and dermis. Our results clearly indicated that postures with loops formed of body parts may lead to substantially higher maximum values of induced in situ electric field strengths than in the case of standard postures due to a highly concentrated current density and in situ electric field strength in the skin-to-skin and skin-to-metal contact regions. With a homogeneous single-layer skin, as is used for even the most recent anatomical body models in exposure assessment, the in situ electric field strength may exceed the basic restrictions in such situations, even when the reference levels and maximum permissible exposure values are not exceeded. However, when using the more realistic two-layer skin model the obtained in situ electric field strengths were substantially lower and no violations of the basic restrictions occurred, which can be explained by the current-limiting effect of the low-conductivity stratum corneum layer.
Semiconductor-based, large-area, flexible, electronic devices
Goyal, Amit [Knoxville, TN
2011-03-15
Novel articles and methods to fabricate the same resulting in flexible, large-area, triaxially textured, single-crystal or single-crystal-like, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.
Semiconductor-based, large-area, flexible, electronic devices on {110}<100> oriented substrates
Goyal, Amit
2014-08-05
Novel articles and methods to fabricate the same resulting in flexible, oriented, semiconductor-based, electronic devices on {110}<100> textured substrates are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.
[100] or [110] aligned, semiconductor-based, large-area, flexible, electronic devices
Goyal, Amit
2015-03-24
Novel articles and methods to fabricate the same resulting in flexible, large-area, [100] or [110] textured, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.
Goyal, Amit [Knoxville, TN
2012-05-15
Novel articles and methods to fabricate the same resulting in flexible, {100}<100> or 45.degree.-rotated {100}<100> oriented, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-01
..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... electronic devices, including wireless communication devices, portable music and data processing devices, and... electronic devices, including wireless communication devices, portable music and data processing devices, and...
Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture
McCown, Steven H [Rigby, ID; Derr, Kurt W [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID
2012-05-08
Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture are described. According to one embodiment, a wireless device monitoring method includes accessing device configuration information of a wireless device present at a secure area, wherein the device configuration information comprises information regarding a configuration of the wireless device, accessing stored information corresponding to the wireless device, wherein the stored information comprises information regarding the configuration of the wireless device, comparing the device configuration information with the stored information, and indicating the wireless device as one of authorized and unauthorized for presence at the secure area using the comparing.
16 CFR § 1507.9 - Toy smoke devices and flitter devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Toy smoke devices and flitter devices. Â... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... fuse and firstfire upon ignition) during normal operation. (b) Toy smoke devices and flitter devices...
16 CFR 1507.9 - Toy smoke devices and flitter devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Toy smoke devices and flitter devices. 1507... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... fuse and firstfire upon ignition) during normal operation. (b) Toy smoke devices and flitter devices...
16 CFR 1507.9 - Toy smoke devices and flitter devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Toy smoke devices and flitter devices. 1507... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... fuse and firstfire upon ignition) during normal operation. (b) Toy smoke devices and flitter devices...
16 CFR 1507.9 - Toy smoke devices and flitter devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Toy smoke devices and flitter devices. 1507... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... fuse and firstfire upon ignition) during normal operation. (b) Toy smoke devices and flitter devices...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-21
... Devices, Portable Music and Data Processing Devices, Computers, and Components Thereof; Institution of... communication devices, portable music and data processing devices, computers, and components thereof by reason... certain wireless communication devices, portable music and data processing devices, computers, and...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-10
..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... importing wireless communication devices, portable music and data processing devices, and tablet computers... certain electronic devices, including wireless communication devices, portable music and data processing...
21 CFR 882.1560 - Skin potential measurement device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Skin potential measurement device. 882.1560... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1560 Skin potential measurement device. (a) Identification. A skin potential measurement device is a general diagnostic device...
21 CFR 882.1560 - Skin potential measurement device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Skin potential measurement device. 882.1560... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1560 Skin potential measurement device. (a) Identification. A skin potential measurement device is a general diagnostic device...
21 CFR 882.1560 - Skin potential measurement device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Skin potential measurement device. 882.1560... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1560 Skin potential measurement device. (a) Identification. A skin potential measurement device is a general diagnostic device...
21 CFR 882.1560 - Skin potential measurement device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skin potential measurement device. 882.1560... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1560 Skin potential measurement device. (a) Identification. A skin potential measurement device is a general diagnostic device...
21 CFR 872.2060 - Jaw tracking device.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2060 Jaw tracking device. (a) Jaw tracking device... Controls Guidance Document: Dental Sonography and Jaw Tracking Devices.” [68 FR 67367, Dec. 2, 2003] ...
21 CFR 872.2050 - Dental sonography device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...
21 CFR 872.2050 - Dental sonography device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...
21 CFR 872.2050 - Dental sonography device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...
21 CFR 872.2050 - Dental sonography device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...
21 CFR 872.2050 - Dental sonography device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental sonography device. 872.2050 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2050 Dental sonography device. (a) Dental sonography device for monitoring—(1) Identification. A dental sonography device for monitoring is an...
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
Processes for multi-layer devices utilizing layer transfer
Nielson, Gregory N; Sanchez, Carlos Anthony; Tauke-Pedretti, Anna; Kim, Bongsang; Cederberg, Jeffrey; Okandan, Murat; Cruz-Campa, Jose Luis; Resnick, Paul J
2015-02-03
A method includes forming a release layer over a donor substrate. A plurality of devices made of a first semiconductor material are formed over the release layer. A first dielectric layer is formed over the plurality of devices such that all exposed surfaces of the plurality of devices are covered by the first dielectric layer. The plurality of devices are chemically attached to a receiving device made of a second semiconductor material different than the first semiconductor material, the receiving device having a receiving substrate attached to a surface of the receiving device opposite the plurality of devices. The release layer is etched to release the donor substrate from the plurality of devices. A second dielectric layer is applied over the plurality of devices and the receiving device to mechanically attach the plurality of devices to the receiving device.
21 CFR 872.1740 - Caries detection device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Caries detection device. 872.1740 Section 872.1740...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1740 Caries detection device. (a) Identification. The caries detection device is a device intended to show the existence of decay in a patient's tooth...
21 CFR 892.2010 - Medical image storage device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...
21 CFR 892.2010 - Medical image storage device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...
21 CFR 892.2010 - Medical image storage device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...
21 CFR 892.2010 - Medical image storage device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...
21 CFR 886.1450 - Corneal radius measuring device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Corneal radius measuring device. 886.1450 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1450 Corneal radius measuring device. (a) Identification. A corneal radius measuring device is an AC-powered device intended to measure...
21 CFR 886.4360 - Ocular surgery irrigation device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...
21 CFR 886.4360 - Ocular surgery irrigation device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...
21 CFR 886.4360 - Ocular surgery irrigation device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...
21 CFR 886.4360 - Ocular surgery irrigation device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...
21 CFR 886.4360 - Ocular surgery irrigation device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ocular surgery irrigation device. 886.4360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4360 Ocular surgery irrigation device. (a) Identification. An ocular surgery irrigation device is a device intended to be suspended over the...
21 CFR 892.2010 - Medical image storage device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical image storage device. 892.2010 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2010 Medical image storage device. (a) Identification. A medical image storage device is a device that provides electronic storage and retrieval...
21 CFR 872.1820 - Dental x-ray exposure alignment device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...
21 CFR 872.1840 - Dental x-ray position indicating device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...
21 CFR 872.1840 - Dental x-ray position indicating device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...
21 CFR 872.1820 - Dental x-ray exposure alignment device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...
21 CFR 872.1820 - Dental x-ray exposure alignment device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...
21 CFR 872.1820 - Dental x-ray exposure alignment device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...
21 CFR 872.1840 - Dental x-ray position indicating device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...
21 CFR 872.1840 - Dental x-ray position indicating device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...
21 CFR 872.1820 - Dental x-ray exposure alignment device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental x-ray exposure alignment device. 872.1820... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1820 Dental x-ray exposure alignment device. (a) Identification. A dental x-ray exposure alignment device is a device intended to position x...
21 CFR 872.1840 - Dental x-ray position indicating device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...
21 CFR 892.2040 - Medical image hardcopy device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...
21 CFR 892.2040 - Medical image hardcopy device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...
21 CFR 892.2040 - Medical image hardcopy device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...
21 CFR 892.2040 - Medical image hardcopy device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...
21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...
21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...
21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...
21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...
21 CFR 892.1610 - Diagnostic x-ray beam-limiting device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Diagnostic x-ray beam-limiting device. 892.1610... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1610 Diagnostic x-ray beam-limiting device. (a) Identification. A diagnostic x-ray beam-limiting device is a device such as a collimator, a...
21 CFR 864.9195 - Blood mixing devices and blood weighing devices.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...
21 CFR 864.9195 - Blood mixing devices and blood weighing devices.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...
21 CFR 864.9195 - Blood mixing devices and blood weighing devices.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...
21 CFR 864.9195 - Blood mixing devices and blood weighing devices.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...
21 CFR 864.9195 - Blood mixing devices and blood weighing devices.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-19
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... certain electronic devices, including wireless communication devices, portable music and data processing...
Continuation of copper and levonorgestrel intrauterine devices: a retrospective cohort study.
Phillips, Sharon J; Hofler, Lisa G; Modest, Anna M; Harvey, Lara F B; Wu, Lily H; Hacker, Michele R
2017-07-01
Studies conflict on whether the duration of use of the copper intrauterine device is longer than that of the levonorgestrel intrauterine device, and whether women who continue using intrauterine devices differ from those who discontinue. We sought to assess continuation rates and performance of levonorgestrel intrauterine devices compared with copper intrauterine devices over a 5-year period. We performed a retrospective cohort study of 1164 individuals who underwent intrauterine device placement at an urban academic medical center. The analysis focused on a comparison of continuation rates between those using levonorgestrel intrauterine device and copper intrauterine device, factors associated with discontinuation, and intrauterine device performance. We assessed the differences in continuation at discrete time points, pregnancy, and expulsion rates using χ 2 tests and calculated hazard ratios using a multivariable Cox model. Of 1164 women who underwent contraceptive intrauterine device insertion, 956 had follow-up data available. At 2 years, 64.9% of levonorgestrel intrauterine device users continued their device, compared with 57.7% of copper intrauterine device users (P = .11). At 4 years, continuation rates were 45.1% for levonorgestrel intrauterine device and 32.6% for copper intrauterine device (P < .01), and at 5 years continuation rates were 28.1% for levonorgestrel intrauterine device and 23.8% for copper intrauterine device (P = .33). Black race, primiparity, and age were positively associated with discontinuation; education was not. The hazard ratio for discontinuation of levonorgestrel intrauterine device compared with copper intrauterine device >4 years was 0.71 (95% confidence interval, 0.55-0.93) and >5 years was 0.82 (95% confidence interval, 0.64-1.05) after adjusting for race, age, parity, and education. Copper intrauterine device users were more likely to experience expulsion (10.2% copper intrauterine device vs 4.9% levonorgestrel intrauterine device, P < .01) over the study period and to become pregnant in the first year of use (1.6% copper intrauterine device vs 0.1% levonorgestrel intrauterine device, P < .01). We found a difference in continuation rates between levonorgestrel and copper intrauterine device users at 4 years but not at 5 years. Copper intrauterine device users were more likely to experience expulsion and pregnancy. Copyright © 2017 Elsevier Inc. All rights reserved.
Continuation of copper and levonorgestrel intrauterine devices: a retrospective cohort study
Phillips, Sharon J.; Hofler, Lisa G.; Modest, Anna M.; Harvey, Lara F. B.; Wu, Lily H.; Hacker, Michele R.
2018-01-01
Background Studies conflict on whether the duration of use of the copper intrauterine device is longer than that of the levonorgestrel intra-uterine device, and whether women who continue using intrauterine devices differ from those who discontinue. Objective We sought to assess continuation rates and performance of levonorgestrel intrauterine devices compared with copper intrauterine devices over a 5-year period. Study Design We performed a retrospective cohort study of 1164 individuals who underwent intrauterine device placement at an urban academic medical center. The analysis focused on a comparison of continuation rates between those using levonorgestrel intrauterine device and copper intrauterine device, factors associated with discontinuation, and intrauterine device performance. We assessed the differences in continuation at discrete time points, pregnancy, and expulsion rates using χ2 tests and calculated hazard ratios using a multivariable Cox model. Results Of 1164 women who underwent contraceptive intrauterine device insertion, 956 had follow-up data available. At 2 years, 64.9% of levonorgestrel intrauterine device users continued their device, compared with 57.7% of copper intrauterine device users (P = .11). At 4 years, continuation rates were 45.1% for levonorgestrel intrauterine device and 32.6% for copper intrauterine device (P < .01), and at 5 years continuation rates were 28.1% for levonorgestrel intrauterine device and 23.8% for copper intrauterine device (P = .33). Black race, primiparity, and age were positively associated with discontinuation; education was not. The hazard ratio for discontinuation of levonorgestrel intrauterine device compared with copper intrauterine device >4 years was 0.71 (95% confidence interval, 0.55–0.93) and >5 years was 0.82 (95% confidence interval, 0.64–1.05) after adjusting for race, age, parity, and education. Copper intrauterine device users were more likely to experience expulsion (10.2% copper intrauterine device vs 4.9% levonorgestrel intrauterine device, P < .01) over the study period and to become pregnant in the first year of use (1.6% copper intrauterine device vs 0.1% levonorgestrel intrauterine device, P < .01). Conclusion We found a difference in continuation rates between levonorgestrel and copper intrauterine device users at 4 years but not at 5 years. Copper intrauterine device users were more likely to experience expulsion and pregnancy. PMID:28315664
Evaluation of tissue interactions with mechanical elements of a transscleral drug delivery device.
Cohen, Sarah J; Chan, Robison V Paul; Keegan, Mark; Andreoli, Christopher M; Borenstein, Jeffrey T; Miller, Joan W; Gragoudas, Evangelos S
2012-03-12
The goal of this work was to evaluate tissue-device interactions due to implantation of a mechanically operated drug delivery system onto the posterior sclera. Two test devices were designed and fabricated to model elements of the drug delivery device-one containing a free-spinning ball bearing and the other encasing two articulating gears. Openings in the base of test devices modeled ports for drug passage from device to sclera. Porous poly(tetrafluoroethylene) (PTFE) membranes were attached to half of the gear devices to minimize tissue ingrowth through these ports. Test devices were sutured onto rabbit eyes for 10 weeks. Tissue-device interactions were evaluated histologically and mechanically after removal to determine effects on device function and changes in surrounding tissue. Test devices were generally well-tolerated during residence in the animal. All devices encouraged fibrous tissue formation between the sclera and the device, fibrous tissue encapsulation and invasion around the device, and inflammation of the conjunctiva. Gear devices encouraged significantly greater inflammation in all cases and a larger rate of tissue ingrowth. PTFE membranes prevented tissue invasion through the covered drug ports, though tissue migrated in through other smaller openings. The torque required to turn the mechanical elements increased over 1000 times for gear devices, but only on the order of 100 times for membrane-covered gear devices and less than 100 times for ball bearing devices. Maintaining a lower device profile, minimizing microscale motion on the eye surface and covering drug ports with a porous membrane may minimize inflammation, decreasing the risk of damage to surrounding tissues and minimizing disruption of device operation.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-04
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data Processing Devices, and Tablet Computers... communication devices, portable music and data processing devices, and tablet computers, imported by Apple Inc...
21 CFR 892.2020 - Medical image communications device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical image communications device. 892.2020... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2020 Medical image communications device. (a) Identification. A medical image communications device provides electronic transfer of medical...
21 CFR 892.2020 - Medical image communications device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical image communications device. 892.2020... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2020 Medical image communications device. (a) Identification. A medical image communications device provides electronic transfer of medical...
21 CFR 892.2020 - Medical image communications device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical image communications device. 892.2020... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2020 Medical image communications device. (a) Identification. A medical image communications device provides electronic transfer of medical...
21 CFR 892.2020 - Medical image communications device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical image communications device. 892.2020... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2020 Medical image communications device. (a) Identification. A medical image communications device provides electronic transfer of medical...
Release strategies for making transferable semiconductor structures, devices and device components
Rogers, John A; Nuzzo, Ralph G; Meitl, Matthew; Ko, Heung Cho; Yoon, Jongseung; Menard, Etienne; Baca, Alfred J
2014-11-25
Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.
Release strategies for making transferable semiconductor structures, devices and device components
Rogers, John A [Champaign, IL; Nuzzo, Ralph G [Champaign, IL; Meitl, Matthew [Raleigh, NC; Ko, Heung Cho [Urbana, IL; Yoon, Jongseung [Urbana, IL; Menard, Etienne [Durham, NC; Baca, Alfred J [Urbana, IL
2011-04-26
Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.
Release strategies for making transferable semiconductor structures, devices and device components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rogers, John A.; Nuzzo, Ralph G.; Meitl, Matthew
2016-05-24
Provided are methods for making a device or device component by providing a multi layer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.
21 CFR 872.1745 - Laser fluorescence caries detection device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Laser fluorescence caries detection device. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1745 Laser fluorescence caries detection device. (a) Identification. A laser fluorescence caries detection device is a laser, a...
Extending Wi-Fi Direct for Automated Operations
2015-03-01
functionalities. These added functionalities include: automatic device discovery, a mutual awareness of capabilities between devices (inter-device capability ...functionalities include: automatic device discove1y, a mutual awareness of capabilities between devices (inter-device capability awareness...Figure 7. P2P Device GO Negotiation Request (The P2P IE includes P2P Capability , P2P Device Info, Group Owner Intent, Configuration Timeout, Listen
21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...
21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...
21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...
21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...
21 CFR 884.5360 - Contraceptive intrauterine device (IUD) and introducer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive intrauterine device (IUD) and... Gynecological Therapeutic Devices § 884.5360 Contraceptive intrauterine device (IUD) and introducer. (a) Identification. A contraceptive intrauterine device (IUD) is a device used to prevent pregnancy. The device is...
21 CFR 872.2060 - Jaw tracking device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Jaw tracking device. 872.2060 Section 872.2060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2060 Jaw tracking device. (a) Jaw tracking device...
21 CFR 872.2060 - Jaw tracking device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Jaw tracking device. 872.2060 Section 872.2060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2060 Jaw tracking device. (a) Jaw tracking device...
21 CFR 872.2060 - Jaw tracking device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Jaw tracking device. 872.2060 Section 872.2060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2060 Jaw tracking device. (a) Jaw tracking device...
21 CFR 872.2060 - Jaw tracking device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Jaw tracking device. 872.2060 Section 872.2060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.2060 Jaw tracking device. (a) Jaw tracking device...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2014 CFR
2014-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2011 CFR
2011-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2013 CFR
2013-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2012 CFR
2012-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
21 CFR 801.437 - User labeling for devices that contain natural rubber.
Code of Federal Regulations, 2010 CFR
2010-04-01
... User labeling for devices that contain natural rubber. (a) Data in the Medical Device Reporting System... of the device packaging, the outside package, container or wrapper, and the immediate device package... panel of the device packaging, the outside package, container or wrapper, and the immediate device...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolenbaugh, Jonathan M.; Naqi, Syed
A method to operate a clutch device in an electro-mechanical transmission mechanically-operatively coupled to an internal combustion engine and at least one electric machine includes, in response to a failure condition detected within a flow control device configured to facilitate flow of hydraulic fluid for operating the clutch device, selectively preventing the flow of hydraulic fluid from entering the flow control device and feeding the clutch device. Synchronization of the clutch device is initiated when the clutch device is intended for activation, and only if the clutch device is synchronized, the flow of hydraulic fluid is selectively permitted to entermore » the flow control device to activate the clutch device.« less
Evaluation of an investigational wearable injector in healthy human volunteers.
Torjman, Marc C; Machnicki, Robert; Lessin, Jennifer; Loeum, Channy; Steinberger, Douglas; Mycroft, Sarah; Joseph, Jeffrey I
2017-01-01
Introduction of a wearable device for subcutaneous delivery of larger volume bolus injections would encourage patient compliance and reduce the burden on healthcare services. With one such wearable device commercially available, this study examined the safety and functionality of an investigational device in volunteers. Four devices were applied to the subject's abdomen: 1) Investigational Device, 2) Investigational Device: subject movement, 3) Control Device: FDA-cleared syringe driver with FDA-cleared infusion set, 4) Control Device: FDA-cleared syringe driver attached to investigational device. Three milliliters of saline were infused through the four devices over 3 minutes. 84 devices were applied to 21 subjects. Three milliliters of saline were safely delivered subcutaneously from the investigational and control devices. Two control devices had occlusions and in each case the pump reached its high pressure limit of 12 psi. VAS pain measurements showed minimal pain for all subjects. Pain scores were significantly (p < 0.001) higher than baseline at the end of injection: mean pain level ranged from 2.0-22.0 mm. The investigational device performed as intended with minimal pain during needle insertion and infusion, and no leaking of fluid at the skin puncture site. Two occlusions occurred with the control devices.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
...] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory... and 11, 2012, the committee will discuss general issues related to medical devices intended for obese...
78 FR 77688 - Ophthalmic Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-24
...] Ophthalmic Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Ophthalmic Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To... Swink, Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave...
21 CFR 880.6310 - Medical device data system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... medical device data; (ii) The electronic storage of medical device data; (iii) The electronic conversion... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical device data system. 880.6310 Section 880... Devices § 880.6310 Medical device data system. (a) Identification. (1) A medical device data system (MDDS...
21 CFR 880.6310 - Medical device data system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... medical device data; (ii) The electronic storage of medical device data; (iii) The electronic conversion... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical device data system. 880.6310 Section 880... Devices § 880.6310 Medical device data system. (a) Identification. (1) A medical device data system (MDDS...
21 CFR 880.6310 - Medical device data system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... medical device data; (ii) The electronic storage of medical device data; (iii) The electronic conversion... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical device data system. 880.6310 Section 880... Devices § 880.6310 Medical device data system. (a) Identification. (1) A medical device data system (MDDS...
21 CFR 880.6310 - Medical device data system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... medical device data; (ii) The electronic storage of medical device data; (iii) The electronic conversion... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical device data system. 880.6310 Section 880... Devices § 880.6310 Medical device data system. (a) Identification. (1) A medical device data system (MDDS...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-19
... Effects Devices and Image Display Devices and Components and Products Containing Same; Notice of... United States after importation of certain motion-sensitive sound effects devices and image display... devices and image display devices and components and products containing same that infringe one or more of...
DeShong, J.A.
1960-03-01
A control-limiting device for monltoring a control system is described. The system comprises a conditionsensing device, a condition-varying device exerting a control over the condition, and a control means to actuate the condition-varying device. A control-limiting device integrates the total movement or other change of the condition-varying device over any interval of time during a continuum of overlapping periods of time, and if the tothl movement or change of the condition-varying device exceeds a preset value, the control- limiting device will switch the control of the operated apparatus from automatic to manual control.
Eager protocol on a cache pipeline dataflow
Ohmacht, Martin; Sugavanam, Krishnan
2012-11-13
A master device sends a request to communicate with a slave device to a switch. The master device waits for a period of cycles the switch takes to decide whether the master device can communicate with the slave device, and the master device sends data associated with the request to communicate at least after the period of cycles has passed since the master device sent the request to communicate to the switch without waiting to receive an acknowledgment from the switch that the master device can communicate with the slave device.
Sezdi, Mana
2016-01-01
A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older technology devices and predictive maintenance for newer high-tech devices. For preventive maintenance development, 589 older technology devices were subjected to performance verification and safety testing (PVST). For predictive maintenance development, the manufacturers' recommendations were used for 134 high-tech devices. These strategies were evaluated in terms of device reliability. This study recommends the use of two different maintenance strategies for old and new devices at hospitals in developing countries. Thus, older technology devices that applied only corrective maintenance will be included in maintenance like high-tech devices.
Sezdi, Mana
2016-01-01
A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older technology devices and predictive maintenance for newer high-tech devices. For preventive maintenance development, 589 older technology devices were subjected to performance verification and safety testing (PVST). For predictive maintenance development, the manufacturers' recommendations were used for 134 high-tech devices. These strategies were evaluated in terms of device reliability. This study recommends the use of two different maintenance strategies for old and new devices at hospitals in developing countries. Thus, older technology devices that applied only corrective maintenance will be included in maintenance like high-tech devices. PMID:27195666
Radiology of cardiac devices and their complications
Dipoce, J; Spindola-Franco, H
2015-01-01
This article familiarizes the reader with several different cardiac devices including pacemakers and implantable cardioverter defibrillators, intra-aortic balloon pumps, ventricular assist devices, valve replacements and repairs, shunt-occluding devices and passive constraint devices. Many cardiac devices are routinely encountered in clinical practice. Other devices are in the early stages of development, but circumstances suggest that they too will become commonly found. The radiologist must be familiar with these devices and their complications. PMID:25411826
Wireless device monitoring systems and monitoring devices, and associated methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCown, Steven H; Derr, Kurt W; Rohde, Kenneth W
Wireless device monitoring systems and monitoring devices include a communications module for receiving wireless communications of a wireless device. Processing circuitry is coupled with the communications module and configured to process the wireless communications to determine whether the wireless device is authorized or unauthorized to be present at the monitored area based on identification information of the wireless device. Methods of monitoring for the presence and identity of wireless devices are also provided.
Localized electrical fine tuning of passive microwave and radio frequency devices
Findikoglu, Alp T.
2001-04-10
A method and apparatus for the localized electrical fine tuning of passive multiple element microwave or RF devices in which a nonlinear dielectric material is deposited onto predetermined areas of a substrate containing the device. An appropriate electrically conductive material is deposited over predetermined areas of the nonlinear dielectric and the signal line of the device for providing electrical contact with the nonlinear dielectric. Individual, adjustable bias voltages are applied to the electrically conductive material allowing localized electrical fine tuning of the devices. The method of the present invention can be applied to manufactured devices, or can be incorporated into the design of the devices so that it is applied at the time the devices are manufactured. The invention can be configured to provide localized fine tuning for devices including but not limited to coplanar waveguides, slotline devices, stripline devices, and microstrip devices.
Processing module operating methods, processing modules, and communications systems
McCown, Steven Harvey; Derr, Kurt W.; Moore, Troy
2014-09-09
A processing module operating method includes using a processing module physically connected to a wireless communications device, requesting that the wireless communications device retrieve encrypted code from a web site and receiving the encrypted code from the wireless communications device. The wireless communications device is unable to decrypt the encrypted code. The method further includes using the processing module, decrypting the encrypted code, executing the decrypted code, and preventing the wireless communications device from accessing the decrypted code. Another processing module operating method includes using a processing module physically connected to a host device, executing an application within the processing module, allowing the application to exchange user interaction data communicated using a user interface of the host device with the host device, and allowing the application to use the host device as a communications device for exchanging information with a remote device distinct from the host device.
Wafer bonded epitaxial templates for silicon heterostructures
Atwater, Jr., Harry A.; Zahler, James M [Pasadena, CA; Morral, Anna Fontcubera I [Paris, FR
2008-03-11
A heterostructure device layer is epitaxially grown on a virtual substrate, such as an InP/InGaAs/InP double heterostructure. A device substrate and a handle substrate form the virtual substrate. The device substrate is bonded to the handle substrate and is composed of a material suitable for fabrication of optoelectronic devices. The handle substrate is composed of a material suitable for providing mechanical support. The mechanical strength of the device and handle substrates is improved and the device substrate is thinned to leave a single-crystal film on the virtual substrate such as by exfoliation of a device film from the device substrate. An upper portion of the device film exfoliated from the device substrate is removed to provide a smoother and less defect prone surface for an optoelectronic device. A heterostructure is epitaxially grown on the smoothed surface in which an optoelectronic device may be fabricated.
Photoelectrochemically driven self-assembly method
Nielson, Gregory N.; Okandan, Murat
2017-01-17
Various technologies described herein pertain to assembling electronic devices into a microsystem. The electronic devices are disposed in a solution. Light can be applied to the electronic devices in the solution. The electronic devices can generate currents responsive to the light applied to the electronic devices in the solution, and the currents can cause electrochemical reactions that functionalize regions on surfaces of the electronic devices. Additionally or alternatively, the light applied to the electronic devices in the solution can cause the electronic devices to generate electric fields, which can orient the electronic devices and/or induce movement of the electronic devices with respect to a receiving substrate. Further, electrodes on a receiving substrate can be biased to attract and form connections with the electronic devices having the functionalized regions on the surfaces. The microsystem can include the receiving substrate and the electronic devices connected to the receiving substrate.
Wafer bonded epitaxial templates for silicon heterostructures
NASA Technical Reports Server (NTRS)
Atwater, Harry A., Jr. (Inventor); Zahler, James M. (Inventor); Morral, Anna Fontcubera I (Inventor)
2008-01-01
A heterostructure device layer is epitaxially grown on a virtual substrate, such as an InP/InGaAs/InP double heterostructure. A device substrate and a handle substrate form the virtual substrate. The device substrate is bonded to the handle substrate and is composed of a material suitable for fabrication of optoelectronic devices. The handle substrate is composed of a material suitable for providing mechanical support. The mechanical strength of the device and handle substrates is improved and the device substrate is thinned to leave a single-crystal film on the virtual substrate such as by exfoliation of a device film from the device substrate. An upper portion of the device film exfoliated from the device substrate is removed to provide a smoother and less defect prone surface for an optoelectronic device. A heterostructure is epitaxially grown on the smoothed surface in which an optoelectronic device may be fabricated.
Event-recording devices with identification codes
NASA Technical Reports Server (NTRS)
Watters, David G. (Inventor); Huestis, David L. (Inventor); Bahr, Alfred J. (Inventor); Vidmar, Robert J. (Inventor)
2003-01-01
A recording device allows wireless interrogation to determine its identity and its state. The state indicates whether one or more physical or chemical events have taken place. In effect, the one or more physical or chemical events are recorded by the device. The identity of the device allows it to be distinguished from a number of similar devices. The recording device may be used in an array of devices that allows wireless probing by an interrogation unit. When probed, each device tells the interrogator who it is and what state it is in. The devices allow multiple use and the interrogator may use a logical reset to determine the state of each device. The interrogator can thus easily identify particular items in an array that have reached a particular condition. The device may record the status of each device in a database to maintain a history for each.
Evaluation of Tissue Interactions with Mechanical Elements of a Transscleral Drug Delivery Device
Cohen, Sarah J.; Chan, Robison V. Paul; Keegan, Mark; Andreoli, Christopher M.; Borenstein, Jeffrey T.; Miller, Joan W.; Gragoudas, Evangelos S.
2012-01-01
The goal of this work was to evaluate tissue-device interactions due to implantation of a mechanically operated drug delivery system onto the posterior sclera. Two test devices were designed and fabricated to model elements of the drug delivery device—one containing a free-spinning ball bearing and the other encasing two articulating gears. Openings in the base of test devices modeled ports for drug passage from device to sclera. Porous poly(tetrafluoroethylene) (PTFE) membranes were attached to half of the gear devices to minimize tissue ingrowth through these ports. Test devices were sutured onto rabbit eyes for 10 weeks. Tissue-device interactions were evaluated histologically and mechanically after removal to determine effects on device function and changes in surrounding tissue. Test devices were generally well-tolerated during residence in the animal. All devices encouraged fibrous tissue formation between the sclera and the device, fibrous tissue encapsulation and invasion around the device, and inflammation of the conjunctiva. Gear devices encouraged significantly greater inflammation in all cases and a larger rate of tissue ingrowth. PTFE membranes prevented tissue invasion through the covered drug ports, though tissue migrated in through other smaller openings. The torque required to turn the mechanical elements increased over 1000 times for gear devices, but only on the order of 100 times for membrane-covered gear devices and less than 100 times for ball bearing devices. Maintaining a lower device profile, minimizing microscale motion on the eye surface and covering drug ports with a porous membrane may minimize inflammation, decreasing the risk of damage to surrounding tissues and minimizing disruption of device operation. PMID:24300189
What people know about electronic devices: A descriptive study
NASA Astrophysics Data System (ADS)
Kieras, D. E.
1982-10-01
Informal descriptive results on the nature of people's natural knowledge of electronic devices are presented. Expert and nonexpert subjects were given an electronic device to examine and describe orally. The devices ranged from familiar everyday devices, to those familiar only to the expert, to unusual devices unfamiliar even to an expert. College students were asked to describe everyday devices from memory. The results suggest that device knowledge consists of the major categories of what the device is for, how it is used, its structure in terms of subdevices, its physical layout, how it works, and its behavior. A preliminary theoretical framework for device knowledge is that it consists of a hierarchy of schemas, corresponding to a hierarchial decomposition of the device into subdevices, with each level containing the major categories of information.
75 FR 35495 - Ophthalmic Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-22
...] Ophthalmic Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Ophthalmic Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To... Glaukos iStent Trabecular Micro-Bypass Stent, Model GTS-100 L/R, sponsored by Glaukos Corp. The device is...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-15
...] Obstetrics and Gynecology Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice AGENCY... an amendment to the notice of meeting of the Obstetrics and Gynecology Devices Panel of the Medical... Obstetrics and Gynecology Devices Panel of the Medical Devices Advisory Committee would be held on September...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-05
...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the..., FDA announced that a meeting of the General and Plastic Surgery Devices Panel of the Medical Devices...
Hardware device binding and mutual authentication
Hamlet, Jason R; Pierson, Lyndon G
2014-03-04
Detection and deterrence of device tampering and subversion by substitution may be achieved by including a cryptographic unit within a computing device for binding multiple hardware devices and mutually authenticating the devices. The cryptographic unit includes a physically unclonable function ("PUF") circuit disposed in or on the hardware device, which generates a binding PUF value. The cryptographic unit uses the binding PUF value during an enrollment phase and subsequent authentication phases. During a subsequent authentication phase, the cryptographic unit uses the binding PUF values of the multiple hardware devices to generate a challenge to send to the other device, and to verify a challenge received from the other device to mutually authenticate the hardware devices.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-08
... Wireless Communication Devices, Tablet Computers, Media Players, and Televisions, and Components Thereof... devices, including wireless communication devices, tablet computers, media players, and televisions, and... wireless communication devices, tablet computers, media players, and televisions, and components thereof...
Williamson, Brittany; Aplin, Tammy; de Jonge, Desleigh; Goyne, Matthew
2017-11-01
To explore the acceptability and value of three wearable GPS devices for older persons and individuals with a disability and safety concerns when accessing the community. This pilot study explored six wearers' and their support persons' experience of using three different wearable GPS devices (a pendant, watch, and mini GPS phone), each for a two-week period. Participants identified safety as the main value of using a wearable GPS device. The acceptability and value of these devices was strongly influenced by device features, ease of use, cost, appearance, the reliability of the GPS coordinates, the wearer's health condition and the users familiarity with technology. Overall, participants indicated that they preferred the pendant. Wearable GPS devices are potentially useful in providing individuals who have safety concerns with reassurance and access to assistance as required. To ensure successful utilization, future device design and device selection should consider the user's familiarity with technology and their health condition. This study also revealed that not all wearable GPS devices provide continuous location tracking. It is therefore critical to ensure that the device's location tracking functions address the wearer's requirements and reason for using the device. Implications for Rehabilitation The acceptability and usability of wearable GPS devices is strongly influenced by the device features, ease of use, cost, appearance, the reliability of the device to provide accurate and timely GPS coordinates, as well as the health condition of the wearer and their familiarity with technology. Wearable GPS devices need to be simple to use and support and training is essential to ensure they are successfully utilized. Not all wearable GPS devices provide continuous location tracking and accuracy of location is impacted by line of sight to satellites. Therefore, care needs to be taken when choosing a suitable device, to ensure that the device's location tracking features are based on the wearer's requirements and value behind using the device.
Techniques for trans-catheter retrieval of embolized Nit-Occlud® PDA-R and ASD-R devices.
Sinha, Sanjay; Levi, Daniel; Peirone, Alejandro; Pedra, Carlos
2018-02-15
Nit-Occlud ® (atrial septal defect) ASD-R and (patent ductus arteriosus) PDA-R devices are used outside the United States for percutaneous closure of the patent ductus arteriosus and atrial septal defects. When embolization occurs, these devices have been difficult to retrieve. Bench simulations of retrieval of PDA-R and ASD-R devices were performed in a vascular model. Retrieval of each device was attempted using snare techniques or with bioptome forceps with a range of devices. The same devices were then intentionally embolized in an animal model. Retrieval methods were systematically tested in a range of sheath sizes, and graded in terms of difficulty and retrieval time. Devices that were grasped by the bioptome in the center of the proximal part of the devices were easily retrieved in both models. Bench studies determined the minimum sheath sizes needed for retrieval of each device with this method. In general sheathes two french sizes greater than the delivery sheath were successful with this technique. Three out of the four PDA-R devices were successfully retrieved in vivo. Two were retrieved by grasping the middle of the PA end of the PDA-R device with a Maslanka bioptome and one small PDA-R device was retrieved using a 10 mm Snare. Four of the five ASD-R devices were retrieved successfully grasping the right atrial ASD-R disc or by passing a wire through the device and snaring this loop. For ASD-R 28 and 30 mm devices, a double bioptome technique was needed to retrieve the device. ASD-R and PDA-R devices can be successfully retrieved in the catheterization lab. It is critical to grab the center portion of the right atrial disc of the ASD-R device or pulmonary portion of the PDA-R device and to use adequately sized sheathes. © 2018 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Kaul, Anupama B. (Inventor); Epp, Larry W. (Inventor); Bagge, Leif (Inventor)
2013-01-01
Carbon nanofiber resonator devices, methods for use, and applications of said devices are disclosed. Carbon nanofiber resonator devices can be utilized in or as high Q resonators. Resonant frequency of these devices is a function of configuration of various conducting components within these devices. Such devices can find use, for example, in filtering and chemical detection.
White, Judith; Carolan-Rees, Grace
2013-01-01
A standardised terminology for describing medical devices can enable safe and unambiguous exchange of information. Proposed changes to EU-wide medical devices regulations mandate the use of such a system. This article reviews two important classification systems for medical devices in the UK. The Global Medical Device Nomenclature (GMDN) provides a classification system specifically for medical devices and diagnostics, and facilitates data exchange between manufacturers and regulators. SNOMED CT is the terminology of choice in the NHS for communicating, sharing and storing information about patients’ healthcare episodes. Harmonisation of GMDN and SNOMED CT will encourage use of single terminology throughout the lifetime of a device; from regulatory approval through clinical use and post-marketing surveillance. Manufacturers will be required to register medical devices with a European device database (Eudamed) and to fit certain devices with a Unique Device Identifier; both are efforts to improve transparency and traceability of medical devices. Successful implementation of these elements depends on having a consistent nomenclature for medical devices. PMID:23885299
Examining the Relationship between Parental Involvement and Mobile Technology Use
NASA Astrophysics Data System (ADS)
Flowers, Toinette M.
Understanding how mobile devices can enhance parent/teacher communication is important because parents play an important part in their children's learning. Research on parents' use of mobile devices to communicate with their children's teachers is limited. The purpose of this cross-sectional correlational study was to determine the relationships between parents' (a) knowledge of using mobile devices, (b) general use of mobile devices, (c) purpose for using mobile devices, (d) perceived ease of using mobile devices, (e) perceived usefulness of mobile devices, (f) attitude toward using mobile devices, and (g) use of mobile devices to communicate with teachers. The study was informed by the technology acceptance model and used a participant pool of 73 parents of high school students attending a Title I high school in a large Midwestern city in the United States. Data were collected using an online survey and analyzed using Pearson's correlations. The study results indicate significant correlations between parents' use of mobile devices to communicate with teachers and knowledge of using mobile devices, purpose for using mobile devices, perceived ease of using mobile devices, perceived usefulness of mobile devices, and attitudes toward using mobile devices. These findings suggest that parental use of mobile devices to communicate with teachers can be enhanced by administrators and school personnel using strategies that consider parents' and the school culture. Social implication includes sharing the results of this study with district and school administrators who have the power to implement programs that encourage and support the use of mobile devices as a communication tool between parents and teachers, therefore increasing parental involvement and ultimately student academic success.
21 CFR 882.5050 - Biofeedback device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Biofeedback device. 882.5050 Section 882.5050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5050 Biofeedback device. (a...
21 CFR 872.3660 - Impression material.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3660 Impression material. (a) Identification. Impression material is a device composed of materials such as alginate or polysulfide intended to be placed... device is intended to provide models for study and for production of restorative prosthetic devices, such...
21 CFR 872.3660 - Impression material.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3660 Impression material. (a) Identification. Impression material is a device composed of materials such as alginate or polysulfide intended to be placed... device is intended to provide models for study and for production of restorative prosthetic devices, such...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-745] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-25
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-745] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers...
Three fundamental devices in one: a reconfigurable multifunctional device in two-dimensional WSe2
NASA Astrophysics Data System (ADS)
Dhakras, Prathamesh; Agnihotri, Pratik; Lee, Ji Ung
2017-06-01
The three pillars of semiconductor device technologies are (1) the p-n diode, (2) the metal-oxide-semiconductor field-effect transistor and (3) the bipolar junction transistor. They have enabled the unprecedented growth in the field of information technology that we see today. Until recently, the technological revolution for better, faster and more efficient devices has been governed by scaling down the device dimensions following Moore’s Law. With the slowing of Moore’s law, there is a need for alternative materials and computing technologies that can continue the advancement in functionality. Here, we describe a single, dynamically reconfigurable device that implements these three fundamental device functions. The device uses buried gates to achieve n- and p-channels and fits into a larger effort to develop devices with enhanced functionalities, including logic functions, over device scaling. As they are all surface conducting devices, we use one material parameter, the interface trap density of states, to describe the key figure-of-merit of each device.
Vreugdenburg, Thomas D; Laurence, Caroline O; Willis, Cameron D; Mundy, Linda; Hiller, Janet E
2014-09-01
To describe the nature and frequency of information presented on direct-to-consumer websites for emerging breast cancer imaging devices. Content analysis of Australian website advertisements from 2 March 2011 to 30 March 2012, for three emerging breast cancer imaging devices: digital infrared thermal imaging, electrical impedance scanning and electronic palpation imaging. Type of imaging offered, device safety, device performance, application of device, target population, supporting evidence and comparator tests. Thirty-nine unique Australian websites promoting a direct-to-consumer breast imaging device were identified. Despite a lack of supporting evidence, 22 websites advertised devices for diagnosis, 20 advertised devices for screening, 13 advertised devices for prevention and 13 advertised devices for identifying breast cancer risk factors. Similarly, advertised ranges of diagnostic sensitivity (78%-99%) and specificity (44%-91%) were relatively high compared with published literature. Direct comparisons with conventional screening tools that favoured the new device were highly prominent (31 websites), and one-third of websites (12) explicitly promoted their device as a suitable alternative. Australian websites for emerging breast imaging devices, which are also available internationally, promote the use of such devices as safe and effective solutions for breast cancer screening and diagnosis in a range of target populations. Many of these claims are not supported by peer-reviewed evidence, raising questions about the manner in which these devices and their advertising material are regulated, particularly when they are promoted as direct alternatives to established screening interventions.
2013-01-01
Introduction Huntington’s disease (HD) is an autosomal dominant disorder caused by an expanded CAG repeat on the short arm of chromosome 4 resulting in cognitive decline, motor dysfunction, and death, typically occurring 15 to 20 years after the onset of motor symptoms. Neuropathologically, HD is characterized by a specific loss of medium spiny neurons in the caudate and the putamen, as well as subsequent neuronal loss in the cerebral cortex. The transgenic R6/2 mouse model of HD carries the N-terminal fragment of the human HD gene (145 to 155 repeats) and rapidly develops some of the behavioral characteristics that are analogous to the human form of the disease. Mesenchymal stem cells (MSCs) have shown the ability to slow the onset of behavioral and neuropathological deficits following intrastriatal transplantation in rodent models of HD. Use of MSCs derived from umbilical cord (UC) offers an attractive strategy for transplantation as these cells are isolated from a noncontroversial and inexhaustible source and can be harvested at a low cost. Because UC MSCs represent an intermediate link between adult and embryonic tissue, they may hold more pluripotent properties than adult stem cells derived from other sources. Methods Mesenchymal stem cells, isolated from the UC of day 15 gestation pups, were transplanted intrastriatally into 5-week-old R6/2 mice at either a low-passage (3 to 8) or high-passage (40 to 50). Mice were tested behaviorally for 6 weeks using the rotarod task, the Morris water maze, and the limb-clasping response. Following behavioral testing, tissue sections were analyzed for UC MSC survival, the immune response to the transplanted cells, and neuropathological changes. Results Following transplantation of UC MSCs, R6/2 mice did not display a reduction in motor deficits but there appeared to be transient sparing in a spatial memory task when compared to untreated R6/2 mice. However, R6/2 mice receiving either low- or high-passage UC MSCs displayed significantly less neuropathological deficits, relative to untreated R6/2 mice. Conclusions The results from this study demonstrate that UC MSCs hold promise for reducing the neuropathological deficits observed in the R6/2 rodent model of HD. PMID:24456799
Hunt, Gene; Lockwood, Rowan; Swaddle, John P.; Horne, David J.
2017-01-01
Assessing the long-term macroevolutionary consequences of sexual selection has been hampered by the difficulty of studying this process in the fossil record. Cytheroid ostracodes offer an excellent system to explore sexual selection in the fossil record because their readily fossilized carapaces are sexually dimorphic. Specifically, males are relatively more elongate than females in this superfamily. This sexual shape difference is thought to arise so that males carapaces can accommodate their very large copulatory apparatus, which can account for up to one-third of body volume. Here we test this widely held explanation for sexual dimorphism in cytheroid ostracodes by correlating investment in male genitalia, a trait in which sexual selection is seen as the main evolutionary driver, with sexual dimorphism of carapace in the genus Cyprideis. We analyzed specimens collected in the field (C. salebrosa, USA; C. torosa, UK) and from collections of the National Museum of Natural History, Washington, DC (C. mexicana). We digitized valve outlines in lateral view to obtain measures of size (valve area) and shape (elongation, measured as length to height ratio), and obtained several dimensions from two components of the hemipenis: the muscular basal capsule, which functions as a sperm pump, and the section that includes the intromittent organ (terminal extension). In addition to the assessment of this primary sexual trait, we also quantified two dimensions of the male secondary sexual trait—where the transformed right walking leg functions as a clasping organ during mating. We also measured linear dimensions from four limbs as indicators of overall (soft-part) body size, and assessed allometry of the soft anatomy. We observed significant correlations in males between valve size, but not elongation, and distinct structural parts of the hemipenis, even after accounting for their shared correlation with overall body size. We also found weak but significant positive correlation between valve elongation and the degree of sexual dimorphism of the walking leg, but only in C. torosa. The correlation between the hemipenis parts, especially basal capsule size and male valve size dimorphism suggests that sexual selection on sperm size, quantity, and/or efficiency of transfer may drive sexual size dimorphism in these species, although we cannot exclude other aspects of sexual and natural selection. PMID:28678866
Susick, Laura L; Lowing, Jennifer L; Bosse, Kelly E; Hildebrandt, Clara C; Chrumka, Alexandria C; Conti, Alana C
2014-08-01
Neonatal alcohol exposure in rodents causes dramatic neurodegenerative effects throughout the developing nervous system, particularly in the striatum, acutely after exposure. These acute neurodegenerative effects are augmented in mice lacking adenylyl cyclases 1 and 8 (AC1/8) as neonatal mice with a genetic deletion of both AC isoforms (DKO) have increased vulnerability to ethanol-induced striatal neurotoxicity compared to wild type (WT) controls. While neonatal ethanol exposure is known to negatively impact cognitive behaviors, such as executive functioning and working memory in adolescent and adult animals, the threshold of ethanol exposure required to impinge upon developmental behaviors in mice has not been extensively examined. Therefore, the purpose of this study was to determine the behavioral effects of neonatal ethanol exposure using various striatal-dependent developmental benchmarks and to assess the impact of AC1/8 deletion on this developmental progression. WT and DKO mice were treated with 2.5 g/kg ethanol or saline on postnatal day (P)6 and later subjected to the wire suspension, negative geotaxis, postural reflex, grid hang, tail suspension and accelerating rotarod tests at various time points. At P30, mice were evaluated for their hypnotic responses to 4.0 g/kg ethanol by using the loss of righting reflex assay and ethanol-induced stimulation of locomotor activity after 2.0 g/kg ethanol. Ethanol exposure significantly impaired DKO performance in the negative geotaxis test while genetic deletion of AC1/8 alone increased grid hang time and decreased immobility time in the tail suspension test with a concomitant increase in hindlimb clasping behavior. Locomotor stimulation was significantly increased in animals that received ethanol as neonates, peaking significantly in ethanol-treated DKO mice compared to ethanol-treated WT controls, while sedation duration following high-dose ethanol challenge was unaffected. These data indicate that the maturational parameters examined in the current study may not be sensitive enough to detect effects of a single ethanol exposure during the brain growth spurt period. Genetic deletion of AC1/8 reveals a role for these cylases in attenuating ethanol-induced behavioral effects in the neonatally-exposed adolescent. Published by Elsevier B.V.
Martínez, Rubén D F; Lamanna, Matthew C; Novas, Fernando E; Ridgely, Ryan C; Casal, Gabriel A; Martínez, Javier E; Vita, Javier R; Witmer, Lawrence M
2016-01-01
We describe Sarmientosaurus musacchioi gen. et sp. nov., a titanosaurian sauropod dinosaur from the Upper Cretaceous (Cenomanian-Turonian) Lower Member of the Bajo Barreal Formation of southern Chubut Province in central Patagonia, Argentina. The holotypic and only known specimen consists of an articulated, virtually complete skull and part of the cranial and middle cervical series. Sarmientosaurus exhibits the following distinctive features that we interpret as autapomorphies: (1) maximum diameter of orbit nearly 40% rostrocaudal length of cranium; (2) complex maxilla-lacrimal articulation, in which the lacrimal clasps the ascending ramus of the maxilla; (3) medial edge of caudal sector of maxillary ascending ramus bordering bony nasal aperture with low but distinct ridge; (4) 'tongue-like' ventral process of quadratojugal that overlaps quadrate caudally; (5) separate foramina for all three branches of the trigeminal nerve; (6) absence of median venous canal connecting infundibular region to ventral part of brainstem; (7) subvertical premaxillary, procumbent maxillary, and recumbent dentary teeth; (8) cervical vertebrae with 'strut-like' centroprezygapophyseal laminae; (9) extremely elongate and slender ossified tendon positioned ventrolateral to cervical vertebrae and ribs. The cranial endocast of Sarmientosaurus preserves some of the most complete information obtained to date regarding the brain and sensory systems of sauropods. Phylogenetic analysis recovers the new taxon as a basal member of Lithostrotia, as the most plesiomorphic titanosaurian to be preserved with a complete skull. Sarmientosaurus provides a wealth of new cranial evidence that reaffirms the close relationship of titanosaurs to Brachiosauridae. Moreover, the presence of the relatively derived lithostrotian Tapuiasaurus in Aptian deposits indicates that the new Patagonian genus represents a 'ghost lineage' with a comparatively plesiomorphic craniodental form, the evolutionary history of which is missing for at least 13 million years of the Cretaceous. The skull anatomy of Sarmientosaurus suggests that multiple titanosaurian species with dissimilar cranial structures coexisted in the early Late Cretaceous of southern South America. Furthermore, the new taxon possesses a number of distinctive morphologies-such as the ossified cervical tendon, extremely pneumatized cervical vertebrae, and a habitually downward-facing snout-that have rarely, if ever, been documented in other titanosaurs, thus broadening our understanding of the anatomical diversity of this remarkable sauropod clade. The latter two features were convergently acquired by at least one penecontemporaneous diplodocoid, and may represent mutual specializations for consuming low-growing vegetation.
Martínez, Rubén D. F.; Lamanna, Matthew C.; Novas, Fernando E.; Ridgely, Ryan C.; Casal, Gabriel A.; Martínez, Javier E.; Vita, Javier R.; Witmer, Lawrence M.
2016-01-01
We describe Sarmientosaurus musacchioi gen. et sp. nov., a titanosaurian sauropod dinosaur from the Upper Cretaceous (Cenomanian—Turonian) Lower Member of the Bajo Barreal Formation of southern Chubut Province in central Patagonia, Argentina. The holotypic and only known specimen consists of an articulated, virtually complete skull and part of the cranial and middle cervical series. Sarmientosaurus exhibits the following distinctive features that we interpret as autapomorphies: (1) maximum diameter of orbit nearly 40% rostrocaudal length of cranium; (2) complex maxilla—lacrimal articulation, in which the lacrimal clasps the ascending ramus of the maxilla; (3) medial edge of caudal sector of maxillary ascending ramus bordering bony nasal aperture with low but distinct ridge; (4) ‘tongue-like’ ventral process of quadratojugal that overlaps quadrate caudally; (5) separate foramina for all three branches of the trigeminal nerve; (6) absence of median venous canal connecting infundibular region to ventral part of brainstem; (7) subvertical premaxillary, procumbent maxillary, and recumbent dentary teeth; (8) cervical vertebrae with ‘strut-like’ centroprezygapophyseal laminae; (9) extremely elongate and slender ossified tendon positioned ventrolateral to cervical vertebrae and ribs. The cranial endocast of Sarmientosaurus preserves some of the most complete information obtained to date regarding the brain and sensory systems of sauropods. Phylogenetic analysis recovers the new taxon as a basal member of Lithostrotia, as the most plesiomorphic titanosaurian to be preserved with a complete skull. Sarmientosaurus provides a wealth of new cranial evidence that reaffirms the close relationship of titanosaurs to Brachiosauridae. Moreover, the presence of the relatively derived lithostrotian Tapuiasaurus in Aptian deposits indicates that the new Patagonian genus represents a ‘ghost lineage’ with a comparatively plesiomorphic craniodental form, the evolutionary history of which is missing for at least 13 million years of the Cretaceous. The skull anatomy of Sarmientosaurus suggests that multiple titanosaurian species with dissimilar cranial structures coexisted in the early Late Cretaceous of southern South America. Furthermore, the new taxon possesses a number of distinctive morphologies—such as the ossified cervical tendon, extremely pneumatized cervical vertebrae, and a habitually downward-facing snout—that have rarely, if ever, been documented in other titanosaurs, thus broadening our understanding of the anatomical diversity of this remarkable sauropod clade. The latter two features were convergently acquired by at least one penecontemporaneous diplodocoid, and may represent mutual specializations for consuming low-growing vegetation. PMID:27115989
Lossless hybridization between photovoltaic and thermoelectric devices.
Park, Kwang-Tae; Shin, Sun-Mi; Tazebay, Abdullah S; Um, Han-Don; Jung, Jin-Young; Jee, Sang-Won; Oh, Min-Wook; Park, Su-Dong; Yoo, Bongyoung; Yu, Choongho; Lee, Jung-Ho
2013-01-01
The optimal hybridization of photovoltaic (PV) and thermoelectric (TE) devices has long been considered ideal for the efficient harnessing solar energy. Our hybrid approach uses full spectrum solar energy via lossless coupling between PV and TE devices while collecting waste energy from thermalization and transmission losses from PV devices. Achieving lossless coupling makes the power output from the hybrid device equal to the sum of the maximum power outputs produced separately from individual PV and TE devices. TE devices need to have low internal resistances enough to convey photo-generated currents without sacrificing the PV fill factor. Concomitantly, a large number of p-n legs are preferred to drive a high Seebeck voltage in TE. Our simple method of attaching a TE device to a PV device has greatly improved the conversion efficiency and power output of the PV device (~30% at a 15°C temperature gradient across a TE device).
Lossless hybridization between photovoltaic and thermoelectric devices
Park, Kwang-Tae; Shin, Sun-Mi; Tazebay, Abdullah S.; Um, Han-Don; Jung, Jin-Young; Jee, Sang-Won; Oh, Min-Wook; Park, Su-Dong; Yoo, Bongyoung; Yu, Choongho; Lee, Jung-Ho
2013-01-01
The optimal hybridization of photovoltaic (PV) and thermoelectric (TE) devices has long been considered ideal for the efficient harnessing solar energy. Our hybrid approach uses full spectrum solar energy via lossless coupling between PV and TE devices while collecting waste energy from thermalization and transmission losses from PV devices. Achieving lossless coupling makes the power output from the hybrid device equal to the sum of the maximum power outputs produced separately from individual PV and TE devices. TE devices need to have low internal resistances enough to convey photo-generated currents without sacrificing the PV fill factor. Concomitantly, a large number of p-n legs are preferred to drive a high Seebeck voltage in TE. Our simple method of attaching a TE device to a PV device has greatly improved the conversion efficiency and power output of the PV device (~30% at a 15°C temperature gradient across a TE device). PMID:23820973
21 CFR 882.4250 - Cryogenic surgical device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cryogenic surgical device. 882.4250 Section 882.4250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4250 Cryogenic surgical device...
21 CFR 882.4250 - Cryogenic surgical device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cryogenic surgical device. 882.4250 Section 882.4250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4250 Cryogenic surgical device...
21 CFR 872.1870 - Sulfide detection device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Sulfide detection device. 872.1870 Section 872.1870 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1870 Sulfide detection device. (a) Identification...
21 CFR 872.1740 - Caries detection device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Caries detection device. 872.1740 Section 872.1740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1740 Caries detection device. (a) Identification...
21 CFR 872.1740 - Caries detection device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Caries detection device. 872.1740 Section 872.1740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1740 Caries detection device. (a) Identification...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
...] International Medical Device Regulators Forum; Medical Device Single Audit Program International Coalition Pilot... Drug Administration (FDA) is announcing participation in the Medical Device Single Audit Program International Coalition Pilot Program. The Medical Device Single Audit Program (MDSAP) was designed and...
21 CFR 866.2580 - Gas-generating device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gas-generating device. 866.2580 Section 866.2580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2580 Gas-generating device...
21 CFR 866.2580 - Gas-generating device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas-generating device. 866.2580 Section 866.2580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2580 Gas-generating device...
21 CFR 866.2580 - Gas-generating device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gas-generating device. 866.2580 Section 866.2580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2580 Gas-generating device...
21 CFR 866.2580 - Gas-generating device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gas-generating device. 866.2580 Section 866.2580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2580 Gas-generating device...
21 CFR 866.2580 - Gas-generating device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas-generating device. 866.2580 Section 866.2580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2580 Gas-generating device...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-30
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-745] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Notice of... communication devices, portable music and data processing devices, computers and components thereof by reason of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-24
... Music and Data Processing Devices, Computers, and Components Thereof; Notice of Receipt of Complaint... complaint entitled Wireless Communication Devices, Portable Music and Data Processing Devices, Computers..., portable music and data processing devices, computers, and components thereof. The complaint names as...
21 CFR 874.5840 - Antistammering device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Antistammering device. 874.5840 Section 874.5840 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5840 Antistammering device. (a...
21 CFR 874.5840 - Antistammering device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Antistammering device. 874.5840 Section 874.5840 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5840 Antistammering device. (a...
21 CFR 874.5840 - Antistammering device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Antistammering device. 874.5840 Section 874.5840 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5840 Antistammering device. (a...
21 CFR 874.5840 - Antistammering device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Antistammering device. 874.5840 Section 874.5840 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5840 Antistammering device. (a...
21 CFR 810.10 - Cease distribution and notification order.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE RECALL AUTHORITY Mandatory Medical Device Recall Procedures § 810... usual name of the device; (iii) The model, catalog, or product code numbers of the device; and (iv) The... opportunity to consult with the agency, FDA finds that there is a reasonable probability that a device...
21 CFR 810.10 - Cease distribution and notification order.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE RECALL AUTHORITY Mandatory Medical Device Recall Procedures § 810... usual name of the device; (iii) The model, catalog, or product code numbers of the device; and (iv) The... opportunity to consult with the agency, FDA finds that there is a reasonable probability that a device...
21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...
21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...
21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...
21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...
21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...
Integrated device architectures for electrochromic devices
Frey, Jonathan Mack; Berland, Brian Spencer
2015-04-21
This disclosure describes systems and methods for creating monolithically integrated electrochromic devices which may be a flexible electrochromic device. Monolithic integration of thin film electrochromic devices may involve the electrical interconnection of multiple individual electrochromic devices through the creation of specific structures such as conductive pathway or insulating isolation trenches.
21 CFR 892.1670 - Spot-film device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...
21 CFR 892.1670 - Spot-film device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...
21 CFR 892.1670 - Spot-film device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...
21 CFR 892.1670 - Spot-film device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-15
...] Center for Devices and Radiological Health 510(k) Implementation: Online Repository of Medical Device... public meeting entitled ``510(k) Implementation: Discussion of an Online Repository of Medical Device... establish an online public repository of medical device labeling and strategies for displaying device...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
.... FDA-2011-N-0103] Microbiology Devices; Classification of In Vitro Diagnostic Device for Bacillus... of the Microbiology Devices Advisory Panel (the Panel). In addition, the proposed rule would... in the Federal Register. 1. Transcript of the FDA Microbiology Devices Panel meeting, March 7, 2002...
21 CFR 892.1670 - Spot-film device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Spot-film device. 892.1670 Section 892.1670 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1670 Spot-film device. (a) Identification. A spot-film... medical purposes to position a radiographic film cassette to obtain radiographs during fluoroscopy. (b...
47 CFR 2.801 - Radiofrequency device defined.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...
21 CFR 886.4170 - Cryophthalmic unit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4170 Cryophthalmic unit. (a) Identification. A cryophthalmic unit is a device that is a probe with a small tip that becomes extremely cold through the controlled use of a refrigerant or gas. The device may be AC-powered. The device is intended to remove...
21 CFR 874.5370 - Tongs antichoke device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Tongs antichoke device. 874.5370 Section 874.5370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5370 Tongs antichoke device. (a...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 874.5370 - Tongs antichoke device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tongs antichoke device. 874.5370 Section 874.5370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5370 Tongs antichoke device. (a...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 874.5370 - Tongs antichoke device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Tongs antichoke device. 874.5370 Section 874.5370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5370 Tongs antichoke device. (a...
21 CFR 874.5370 - Tongs antichoke device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Tongs antichoke device. 874.5370 Section 874.5370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5370 Tongs antichoke device. (a...
21 CFR 874.5370 - Tongs antichoke device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Tongs antichoke device. 874.5370 Section 874.5370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5370 Tongs antichoke device. (a...
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
Methods and devices for fabricating and assembling printable semiconductor elements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nuzzo, Ralph G.; Rogers, John A.; Menard, Etienne
The invention provides methods and devices for fabricating printable semiconductor elements and assembling printable semiconductor elements onto substrate surfaces. Methods, devices and device components of the present invention are capable of generating a wide range of flexible electronic and optoelectronic devices and arrays of devices on substrates comprising polymeric materials. The present invention also provides stretchable semiconductor structures and stretchable electronic devices capable of good performance in stretched configurations.
Methods and devices for fabricating and assembling printable semiconductor elements
Nuzzo, Ralph G; Rogers, John A; Menard, Etienne; Lee, Keon Jae; Khang, Dahl-Young; Sun, Yugang; Meitl, Matthew; Zhu, Zhengtao
2014-03-04
The invention provides methods and devices for fabricating printable semiconductor elements and assembling printable semiconductor elements onto substrate surfaces. Methods, devices and device components of the present invention are capable of generating a wide range of flexible electronic and optoelectronic devices and arrays of devices on substrates comprising polymeric materials. The present invention also provides stretchable semiconductor structures and stretchable electronic devices capable of good performance in stretched configurations.
2015-11-20
The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.
The Importance of State and Context in Safe Interoperable Medical Systems
Jaffe, Michael B.; Robkin, Michael; Rausch, Tracy; Arney, David; Goldman, Julian M.
2016-01-01
This paper describes why “device state” and “patient context” information are necessary components of device models for safe interoperability. This paper includes a discussion of the importance of describing the roles of devices with respect to interactions (including human user workflows involving devices, and device to device communication) within a system, particularly those intended for use at the point-of-care, and how this role information is communicated. In addition, it describes the importance of clinical scenarios in creating device models for interoperable devices. PMID:27730013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chernoguzov, Alexander; Markham, Thomas R.; Haridas, Harshal S.
A method includes generating at least one access vector associated with a specified device in an industrial process control and automation system. The specified device has one of multiple device roles. The at least one access vector is generated based on one or more communication policies defining communications between one or more pairs of devices roles in the industrial process control and automation system, where each pair of device roles includes the device role of the specified device. The method also includes providing the at least one access vector to at least one of the specified device and one ormore » more other devices in the industrial process control and automation system in order to control communications to or from the specified device.« less
Progress and Prospects in Stretchable Electroluminescent Devices
NASA Astrophysics Data System (ADS)
Wang, Jiangxin; Lee, Pooi See
2017-03-01
Stretchable electroluminescent (EL) devices are a new form of mechanically deformable electronics that are gaining increasing interests and believed to be one of the essential technologies for next generation lighting and display applications. Apart from the simple bending capability in flexible EL devices, the stretchable EL devices are required to withstand larger mechanical deformations and accommodate stretching strain beyond 10%. The excellent mechanical conformability in these devices enables their applications in rigorous mechanical conditions such as flexing, twisting, stretching, and folding.The stretchable EL devices can be conformably wrapped onto arbitrary curvilinear surface and respond seamlessly to the external or internal forces, leading to unprecedented applications that cannot be addressed with conventional technologies. For example, they are in demand for wide applications in biomedical-related devices or sensors and soft interactive display systems, including activating devices for photosensitive drug, imaging apparatus for internal tissues, electronic skins, interactive input and output devices, robotics, and volumetric displays. With increasingly stringent demand on the mechanical requirements, the fabrication of stretchable EL device is encountering many challenges that are difficult to resolve. In this review, recent progresses in the stretchable EL devices are covered with a focus on the approaches that are adopted to tackle materials and process challenges in stretchable EL devices and delineate the strategies in stretchable electronics. We first introduce the emission mechanisms that have been successfully demonstrated on stretchable EL devices. Limitations and advantages of the different mechanisms for stretchable EL devices are also discussed. Representative reports are reviewed based on different structural and material strategies. Unprecedented applications that have been enabled by the stretchable EL devices are reviewed. Finally, we summarize with our perspectives on the approaches for the stretchable EL devices and our proposals on the future development in these devices.
Gagliardi, Anna R; Ducey, Ariel; Lehoux, Pascale; Turgeon, Thomas; Kolbunik, Jeremy; Ross, Sue; Trbovich, Patricia; Easty, Anthony; Bell, Chaim; Urbach, David R
2017-12-22
Little research has examined how physicians choose medical devices for treating individual patients to reveal if interventions are needed to support decision-making and reduce device-associated morbidity and mortality. This study explored factors that influence choice of implantable device from among available options. A descriptive qualitative approach was used. Physicians who implant orthopedic and cardiovascular devices were identified in publicly available directories and web sites. They were asked how they decided what device to use in a given patient, sources of information they consulted, and how patients were engaged in decision-making. Sampling was concurrent with data collection and analysis to achieve thematic saturation. Data were analyzed using constant comparative technique by all members of the research team. Twenty-two physicians from five Canadian provinces (10 cardiovascular, 12 orthopedic; 8, 10 and 4 early, mid and late career, respectively) were interviewed. Responses did not differ by specialty, geographic region or career stage. Five major categories of themes emerged that all influence decision-making about a range of devices, and often compromise choice of the most suitable device for a given patient, potentially leading to sub-optimal clinical outcomes: lack of evidence on device performance, patient factors, physician factors, organizational and health system factors, and device and device market factors. In the absence of evidence from research or device registries, tacit knowledge from trusted colleagues and less-trusted industry representatives informed device choice. Patients were rarely engaged in decision-making. Physician preference for particular devices was a barrier to acquiring competency in devices potentially more suitable for patients. Access to suitable devices was further limited to the number of comparable devices on the market, local inventory and purchasing contract specifications. This study revealed that decision-making about devices is complex, cognitively challenging and constrained by several factors limiting access to and use of devices that could optimize patient outcomes. Further research is needed to assess the impact of these constraints on clinical outcomes, and develop interventions that optimize decision-making about device choice for treating given patients.
[Comparative study of device labeling regulation in U.S.A. and China].
Li, Fei; Wei, Jing; Ma, Yanbin; Li, Zhu
2010-09-01
To provide references for the evolvement of medical devices labeling and manual administration in China, By content analysis, 10 juristic documents relevant to device labeling and manual were collected from FDA website, compared to which, the federal regulation was mainly analyzed. There are five main differences of device labeling regulation between U.S.A. and China: juristic system, administrative scope, administrative target, characteristics and practice, A set of comprehensive juristic system for device labeling has been established by FDA. from which China should draw experience, to administrate the prescription devices and the over-the-counter devices in classification, and set up device labeling guidance, thus guarantee the safety and efficacy of device.
Surface Acoustic Wave Monitor for Deposition and Analysis of Ultra-Thin Films
NASA Technical Reports Server (NTRS)
Hines, Jacqueline H. (Inventor)
2015-01-01
A surface acoustic wave (SAW) based thin film deposition monitor device and system for monitoring the deposition of ultra-thin films and nanomaterials and the analysis thereof is characterized by acoustic wave device embodiments that include differential delay line device designs, and which can optionally have integral reference devices fabricated on the same substrate as the sensing device, or on a separate device in thermal contact with the film monitoring/analysis device, in order to provide inherently temperature compensated measurements. These deposition monitor and analysis devices can include inherent temperature compensation, higher sensitivity to surface interactions than quartz crystal microbalance (QCM) devices, and the ability to operate at extreme temperatures.
21 CFR 872.1745 - Laser fluorescence caries detection device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1745 Laser fluorescence caries... fluorescence detector housed in a dental handpiece, and a control console that performs device calibration, as...
21 CFR 872.1745 - Laser fluorescence caries detection device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1745 Laser fluorescence caries... fluorescence detector housed in a dental handpiece, and a control console that performs device calibration, as...
76 FR 48871 - Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-09
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Immunology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-07
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of Meeting AGENCY... postponing the meeting of the Immunology Devices Panel of the Medical Devices Advisory Committee scheduled...
76 FR 6625 - Neurological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-07
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Neurological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Neurological Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-09
...] Neurological Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice AGENCY: Food and Drug... notice of meeting of the Neurological Devices Panel of the Medical Devices Advisory Committee. This... INFORMATION: In the Federal Register of February 7, 2011, FDA announced that a meeting of the Neurological...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-22
...] Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and... of Committee: Circulatory System Devices Panel of the Medical Devices Advisory Committee. General... also comes with a sheath, introducer, loader, dilator, balloon (used to pre-dilate the native annulus...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-27
...] Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and... of Committee: Circulatory System Devices Panel of the Medical Devices Advisory Committee. General..., introducer, loader, dilator, balloon (used to pre-dilate the native annulus) and a crimper. FDA intends to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-08
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Microbiology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-07
... Drug Administration 21 CFR Part 866 Microbiology Devices; Classification of In Vitro Diagnostic Device... CFR Part 866 [Docket No. FDA-2011-N-0729] Microbiology Devices; Classification of In Vitro Diagnostic... of the Microbiology Devices Advisory Panel (the panel). FDA is publishing in this document the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-23
...] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory... committee will discuss, make recommendations, and vote on information related to the PMA for the LAP-BAND...