Sample records for class iv laser

  1. Optical radiation hazards of laser welding processes. Part II: CO2 laser.

    PubMed

    Rockwell, R J; Moss, C E

    1989-08-01

    There has been an extensive growth within the last five years in the use of high-powered lasers in various metalworking processes. The two types of lasers used most frequently for laser welding/cutting processes are the Neodymium-yttrium-aluminum-garnet (Nd:YAG) and the carbon dioxide (CO2) systems. When such lasers are operated in an open beam configuration, they are designated as a Class IV laser system. Class IV lasers are high-powered lasers that may present an eye and skin hazard under most common exposure conditions, either directly or when the beam has been diffusely scattered. Significant control measures are required for unenclosed (open beam), Class IV laser systems since workers may be exposed to scattered or reflected beams during the operation, maintenance, and service of these lasers. In addition to ocular and/or skin exposure hazards, such lasers also may present a multitude of nonlaser beam occupational concerns. Radiant energy measurements are reported for both the scattered laser radiation and the plasma-related plume radiations released during typical high-powered CO2 laser-target interactions. In addition, the application of the nominal hazard zone (NHZ) and other control measures also are discussed with special emphasis on Class IV industrial CO2 laser systems.

  2. New laser protective eyewear

    NASA Astrophysics Data System (ADS)

    McLear, Mark

    1996-04-01

    Laser technology has significantly impacted our everyday life. Lasers are now used to correct your vision, clear your arteries, and are used in the manufacturing of such diverse products as automobiles, cigarettes, and computers. Lasers are no longer a research tool looking for an application. They are now an integral part of manufacturing. In the case of Class IV lasers, this explosion in laser applications has exposed thousands of individuals to potential safety hazards including eye damage. Specific protective eyewear designed to attenuate the energy of the laser beam below the maximum permissible exposure is required for Class 3B and Class IV lasers according to laser safety standards.

  3. State laser regulations: Arizona's approach and experience

    NASA Astrophysics Data System (ADS)

    Barat, Kenneth L.

    1992-06-01

    Approximately a dozen states have regulatory or statutory authority in the area of nonionizing radiation. With only half that number having established laser regulations. Examples are Texas, Florida, Arizona, Mass. many more are considering establishing such rules, such as N.J., Il., Neb. On the federal level, the Food and Drug Administration has been the most active entity. OSHA has just recently established laser safety guidelines for its inspection staff. In March of 1990 the State of Arizona enacted rules for the control of Nonionizing radiation. This fell under Article 14 of Tittle 12 of the Arizona Administrative Code, which is under the authority of the Arizona Radiation Regulatory Agency. The rules cover a wide range of nonionizing sources, but the major emphasis is in the area of laser devices. While all class lasers fall under Article 14, only Class IIIb and Class IV laser use facilities are required to be registered and inspected by the agency. The rules apply to all Class IIIb and Class IV laser users, meaning medical, industrial, entertainment, and also research facilities.

  4. Assessment of feasibility and efficacy of Class IV laser therapy for postoperative pain relief in off-pump coronary artery bypass surgery patients: A pilot study

    PubMed Central

    Karlekar, Anil; Bharati, Saswata; Saxena, Ravindra; Mehta, Kanchan

    2015-01-01

    Background: Laser therapy, for its established analgesic properties with minimal side effects, has been used for the treatment of chronic pain. However, it has not been used for the treatment of acute postoperative pain. This pilot study was designed to assess the feasibility and efficacy of Class IV laser on postoperative pain relief following off-pump coronary artery bypass graft (OPCABG) surgery, as a component of multimodal analgesia (MMA) technique. Methods: This open observational prospective study comprised of 100 adult patients (84 male, 16 female) who underwent OPCABG through sternotomy. For postoperative analgesia, they were subjected to laser therapy subjected to laser therapy in addition to the standard institutional pain management protocol comprising of IV infusion/bolus of tramadol and paracetamol and fentanyl bolus as rescue analgesic. Pain intensity was measured by Verbal Rating Scale (VRS). The laser therapy was scheduled as once a day regime for three consecutive postoperative days (PODs) starting on POD 1, 30 min following tracheal extubation. The subsequent laser applications were also scheduled at the same time of the day as on day 1 if VRS was ≥5. 10 W Class IV laser was applied over 150 cm2 sternal wound area for 150 s. VRS was used to assess pain severity and was recorded for statistical analysis using Friedman Test. Results: The mean (standard deviation [SD]) VRS of all the 100 patients just before application of the first dose of laser was 7.31 (0.94) while on MMT; the same fell to 4.0 (1.279) and 3.40 (2.697) at 1 h and 24 h respectively following first dose of laser. The change of VRS over first 24 h among all the 100 patients was statistically significant (P = 0.000). Laser was re-applied in 40 patients whose VRS was ≥5 (mean [SD] – 6.38 [0.868]) at 24th h. After receiving the 2nd dose of laser the VRS scores fell significantly (P = 0.000) and became 0 at 54th h. No patients required 3rd dose of the laser. No patient required rescue analgesic while on laser therapy. Conclusion: Class IV laser can be an effective technique for postoperative analgesia following OPCABG surgery through sternotomy when included as a component of MMA technique. PMID:26139735

  5. Optical radiation hazards of laser welding processes. Part 1: Neodymium-YAG laser.

    PubMed

    Rockwell, R J; Moss, C E

    1983-08-01

    High power laser devices are being used for numerous metalworking processes such as welding, cutting and heat treating. Such laser devices are totally enclosed either by the manufacturer or the end-user. When this is done, the total laser system is usually certified by the manufacturer following the federal requirements of the Code of Federal Regulations (CFR) 1040.10 and 10.40.11 as a Class I laser system. Similarly, the end-user may also reclassify an enclosed high-power laser into the Class I category following the requirements of the American National Standards Institute (ANSI) Z-136.1 (1980) standard. There are, however, numerous industrial laser applications where Class IV systems are required to be used in an unenclosed manner. In such applications, there is concern for both ocular and skin hazards caused by direct and scattered laser radiation, as well as potential hazards caused by the optical radiation created by the laser beam's interaction with the metal (i.e. the plume radiation). Radiant energy measurements are reported for both the scattered laser radiation and the resultant plume radiations which were produced during typical unenclosed Class IV Neodymium-YAG laser welding processes. Evaluation of the plume radiation was done with both radiometric and spectroradiometric measurement equipment. The data obtained were compared to applicable safety standards.

  6. Reporting guide for laser-light shows and displays (21 CFR 1002)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The guide is to be used for reporting laser-light shows or displays incorporating Class IIIb or Class IV lasers only. Separate reports are not required for shows or displays that incorporate Class I, IIa, II, or IIIa laser-projection systems. Such show descriptions must be included in the user instructions and the report for the laser projector. Laser projectors used in any light shows or displays regardless of the class of the projector must be certified by the manufacturer and reported using the guide titled, Guide for Preparing Initial Reports and Model Change Reports on Lasers and Products Containing Lasers, HHSmore » Publication FDA 86-8259. These guides assist manufacturers in providing the information that the Center for Devices and Radiological Health (CDRH) needs to determine how laser-light-shown projections and laser-light shows comply with the Federal standard for laser products (21 CDR 1040.10 and 1040.11) and with the conditions of an approved variance.« less

  7. For the safe use of lasers in educational institutions: elementary through university

    NASA Astrophysics Data System (ADS)

    Seeber, Fredrick P.

    1995-10-01

    The use of lasers by the academic community continues to dramatically escalate. Academia is inundated with a profusion of lasers, each with a diverse function. Traditional departments such as biology, chemistry, and physics have introduced the use of lasers as an essential element of tutelage. Even the more distinctive departments such as Cancer Research, Civil Engineering, Earth and Planetary Science, Plasma Fusion, Spectroscopy, and so forth, have incorporated the laser in the composition of their educational mechanism. The literature indicates most ocular accidents happen during alignment procedures, which is an everyday activity for educational laboratories. Also, the improper use of laser safety eye wear is a major area of concern for laser safety in education institutions. More Class II, III, and IV lasers are used in universities, colleges, laser electro-optic technical colleges and high schools than probably any other area: for teaching, research, laboratory experiments, and demonstrations. Relatively large numbers of students work in laboratory groups in confined area, with various lasers of different wavelengths in the same laboratory. Open cavity and beam paths of Class IV lasers are common in these environments. Most educational institutions do not have laser safety officers or standard operation procedures. This paper will discuss the development of a new laser safety standard by an ANSI ad-hoc committee and by the executive committee of the ANSI Z-136 intended to provide adequate, reasonable, and practical guidance for educators, students, and spectators found in classrooms, lecture halls, and laboratories associated with universities, colleges, high, and elementary schools.

  8. Laser-excited luminescence and absorption study of mixed valence for K 2Pt(CN) 4—K 2Pt(CN) 6 crystals

    NASA Astrophysics Data System (ADS)

    Kasi Viswanath, A.; Smith, Wayne L.; Patterson, H.

    1982-04-01

    Crystals of K 2Pt(CN) 6 doped with Pt(CN) 2-4 show an absorption band at 337 nm which is assigned as a mixed-valence (MV) transition from Pt (II) to Pt(IV). From a Hush model analysis, the absorption band is interpreted to be class II in the Day—Robin scheme. When the MV band is laser excited at 337 nm, emmision is observed from Pt(CN) 2-4 clusters.

  9. Microleakage of class V resin composite restorations after bur, air-abrasion or Er:YAG laser preparation.

    PubMed

    Corona, S A; Borsatto, M; Dibb, R G; Ramos, R P; Brugnera, A; Pécora, J D

    2001-01-01

    This in vitro study compared the microleakage of Class V resin composite restorations placed in cavities prepared with a high-speed dental bur, air-abrasion or Er:YAG laser. Twenty sound extracted human third molars were selected and randomly assigned to four equal Groups (n=10): Group I, cavities were cut by dental drill at high-speed; Group II, aluminum oxide air-abrasion was used for cavity preparation, and in Groups III and IV, cavities were prepared by Er:YAG laser. Following cavity preparation, Groups I and II were acid-etched, Group III was treated only by Er:YAG laser and Group IV was conditioned by Er:YAG laser followed by acid-etching. Cavities were restored (Single Bond + Z-100) and the teeth stored for seven days in distilled water. Then, the restorations were polished and the specimens thermocycled, immersed in a 0.2% Rhodamine solution, sectioned and analyzed for leakage at the occlusal (enamel) and cervical (dentin/cementum) interfaces using an optical microscope connected to a video camera. The images were digitized and software was utilized for microleakage assessment. Upon analyzing the results, statistically significant differences (p<0.01) between the occlusal and cervical regions for all groups was observed, and, as a rule, there was better marginal sealing at the enamel margins. The highest degree of infiltration was observed for cavities prepared and treated exclusively by Er:YAG (Group III). The other experimental groups showed statistical similarities in the amount of marginal leakage at the enamel margins. However, at the cervical margins, there was a significant difference (p<0.05) between Group I and the remaining groups. None of the techniques completely eliminated marginal microleakage at the dentin/ cementum margins.

  10. Laser entertainment and light shows in education

    NASA Astrophysics Data System (ADS)

    Sabaratnam, Andrew T.; Symons, Charles

    2002-05-01

    Laser shows and beam effects have been a source of entertainment since its first public performance May 9, 1969, at Mills College in Oakland, California. Since 1997, the Photonics Center, NgeeAnn Polytechnic, Singapore, has been using laser shows as a teaching tool. Students are able to exhibit their creative skills and learn at the same time how lasers are used in the entertainment industry. Students will acquire a number of skills including handling three- phase power supply, operation of cooling system, and laser alignment. Students also acquire an appreciation of the arts, learning about shapes and contours as they develop graphics for the shows. After holography, laser show animation provides a combination of the arts and technology. This paper aims to briefly describe how a krypton-argon laser, galvanometer scanners, a polychromatic acousto-optic modulator and related electronics are put together to develop a laser projector. The paper also describes how students are trained to make their own laser animation and beam effects with music, and at the same time have an appreciation of the operation of a Class IV laser and the handling of optical components.

  11. Theodolite with CCD Camera for Safe Measurement of Laser-Beam Pointing

    NASA Technical Reports Server (NTRS)

    Crooke, Julie A.

    2003-01-01

    The simple addition of a charge-coupled-device (CCD) camera to a theodolite makes it safe to measure the pointing direction of a laser beam. The present state of the art requires this to be a custom addition because theodolites are manufactured without CCD cameras as standard or even optional equipment. A theodolite is an alignment telescope equipped with mechanisms to measure the azimuth and elevation angles to the sub-arcsecond level. When measuring the angular pointing direction of a Class ll laser with a theodolite, one could place a calculated amount of neutral density (ND) filters in front of the theodolite s telescope. One could then safely view and measure the laser s boresight looking through the theodolite s telescope without great risk to one s eyes. This method for a Class ll visible wavelength laser is not acceptable to even consider tempting for a Class IV laser and not applicable for an infrared (IR) laser. If one chooses insufficient attenuation or forgets to use the filters, then looking at the laser beam through the theodolite could cause instant blindness. The CCD camera is already commercially available. It is a small, inexpensive, blackand- white CCD circuit-board-level camera. An interface adaptor was designed and fabricated to mount the camera onto the eyepiece of the specific theodolite s viewing telescope. Other equipment needed for operation of the camera are power supplies, cables, and a black-and-white television monitor. The picture displayed on the monitor is equivalent to what one would see when looking directly through the theodolite. Again, the additional advantage afforded by a cheap black-and-white CCD camera is that it is sensitive to infrared as well as to visible light. Hence, one can use the camera coupled to a theodolite to measure the pointing of an infrared as well as a visible laser.

  12. IV INTERNATIONAL CONFERENCE ON ATOM AND MOLECULAR PULSED LASERS (AMPL'99): IV International Conference on Atomic and Molecular Pulsed Gas Lasers (AMPL'99)

    NASA Astrophysics Data System (ADS)

    Evtushenko, Gennadii S.; Kopylova, T. N.; Soldatov, A. N.; Tarasenko, Viktor F.; Yakovlenko, Sergei I.; Yancharina, A. M.

    2000-06-01

    A brief review of the most interesting papers presented at the IV International Conference on Atomic and Molecular Pulsed Gas Lasers (AMPL'99), which was held in Tomsk, September 13-17, 1999, is provided.

  13. 40 CFR 144.23 - Class IV wells.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Class IV wells. 144.23 Section 144.23... INJECTION CONTROL PROGRAM Authorization of Underground Injection by Rule § 144.23 Class IV wells. (a) Injection into existing Class IV wells is authorized for up to six months after approval or promulgation of...

  14. 40 CFR 144.23 - Class IV wells.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Class IV wells. 144.23 Section 144.23... INJECTION CONTROL PROGRAM Authorization of Underground Injection by Rule § 144.23 Class IV wells. (a) Injection into existing Class IV wells is authorized for up to six months after approval or promulgation of...

  15. 40 CFR 144.23 - Class IV wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Class IV wells. 144.23 Section 144.23... INJECTION CONTROL PROGRAM Authorization of Underground Injection by Rule § 144.23 Class IV wells. (a) Injection into existing Class IV wells is authorized for up to six months after approval or promulgation of...

  16. [Classification of laser irradiation and safety measures].

    PubMed

    Takac, S; Stojanović, S

    1998-01-01

    The use of lasers in medicine and especially surgery is rapidly expanding in many disciplines from clinical laboratory to the office practice and operating room. It is essential that users of this powerful tool have knowledge of their potential hazards and the measures to protect patients and personnel against injuries or undesired effects. Below, we have included information about the way lasers are classified; the development of protective standards; the current status of protection standards that apply to lasers, especially those used in medicine/surgery; the specific kinds of hazards associated with medical/surgical applications; and the measures by which hazards have been controlled. Since laser technology is still a young field, it is likely that problems unknown at present will occur and methodologies for controlling hazards will evolve. The American National Standards Committee produced the first consensus standard Z136.1 in 1973. The Standard was revised in 1976 to accommodate differences in biological effects for different wavelengths in the visible spectrum. The ANSI Standard has been revised again in 1980, and currently (1984) there are two additional standards in preparation, Z136.2 and 136.3, which treat the safe use of light-emitting diodes and the safe use of lasers in the health care environment, respectively. Most surgical and medical lasers are Class III or IV. Some lasers have a Class IV therapy level beam plus a Class I or II alignment beam. When using lasers, it is possible to generate incandescence or fluorescence in an irradiated object. This can occur even with protective eyewear, because the correlated radiations are usually of a different wavelength. Generally, this should not be a problem when beams are directed at biological material. However, hazard could be caused by lasers designed to produce fluorescence. Control of correlative radiation in a laser system is required in the federal regulations. Hazards of lasers may be grouped as those to the eye, skin and associated hazards, fire, x-rays, electrical, fumes, toxic materials, etc. Effects on tissue are governed by the following factors:--the energy or power density of the beam;--the absorption in tissue at the laser wavelength;--the time the beam is held at a given area.;--the protective effects of heat removal by thermal conduction and by circulation. Eye hazards include thermal burns or acoustical disruption (shock waves) from high-powered or high-energy beams in the visible and near infrared wavelengths. Direct beam exposure or specular or diffuse reflaction from these very high-power lasers can also cause injuries to other parts of the retina. For example, beams can directly penetrate through the sclera and cause retinal injury. Near ultraviolet (less than 400 hm) and far infrared (.3000 hm including CO2 lasers) can cause moderate to severe corneal burns. Far ultraviolet (200-315 nm), mid infrared (1400-3000 nanometers) can cause welders' flash or snow blindness and chronic exposure could cause cataract, and exposure to ultraviolet rays may be carcinogenic. For CO2 lasers, the far infrared radiation is attenuated by plastic goggles, or by glasses, or quartz. Other eyewear with special filters is used for different lasers. The whole personnel who may be exposed to direct beams, specular reflections, and many times diffuse reflections must wear protective eyewear. In all cases the surgeon and others viewing the procedure through the endoscope need glasses or suitable protective lenses installed in the endoscope. Persons who are not viewing the beam may not need to wear protective glasses with the same level of optical density. Glasses may be selected to provide protection for lasers operating in the visible wavelength to the point where the normal aversion response could protect the individual.

  17. Treatment burden in patients with at least one class IV or V CFTR mutation.

    PubMed

    Dewulf, Jonas; Vermeulen, François; Wanyama, Simeon; Thomas, Muriel; Proesmans, Marijke; Dupont, Lieven; De Boeck, Kris

    2015-12-01

    CFTR mutations are grouped according to disease-causing mechanism. Several studies demonstrated that patients having at least one mutation of class IV/V, present with a milder phenotype, but little is known about their relative treatment burden. We compared treatment burden between patients with two class I, II, or III mutations and patients with at least one mutation of class IV/V in the 2010 database of the Belgian CF Registry. We calculated a "Treatment Burden Index" (TBI) by assigning long term therapies to categories low, medium and high intensity, for differential weighing in the total score. There were 779 patients with two known class I/II/III mutations and 94 patients with at least one class IV/V mutation. Compared to class I/II/III, class IV/V patients had a lower median number of clinic visits (4 vs. 5; P < 0.001), a lower risk of hospitalization (24.7% vs. 50.8%; P < 0.001) and intravenous antibiotic treatment (23.5% vs. 46.0%; P < 0.001) and a lower median TBI (6 vs. 9; P < 0.001). These differences remained significant when only class IV/V patients with pancreatic insufficiency (n = 31) were considered. This study clearly demonstrates the significantly lower treatment burden in patients with CF and at least one class IV/V mutation compared to patients with two class I/II/III mutations and contributes to providing better individual counseling at time of diagnosis. © 2015 Wiley Periodicals, Inc.

  18. Laser Safety Evaluation of the MILES and Mini MILES Laser Emitting Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AUGUSTONI, ARNOLD L.

    Laser safety evaluation and output emission measurements were performed (during October and November 2001) on SNL MILES and Mini MILES laser emitting components. The purpose, to verify that these components, not only meet the Class 1 (eye safe) laser hazard criteria of the CDRH Compliance Guide for Laser Products and 21 CFR 1040 Laser Product Performance Standard; but also meet the more stringent ANSI Std. z136.1-2000 Safe Use of Lasers conditions for Class 1 lasers that govern SNL laser operations. The results of these measurements confirmed that all of the Small Arms Laser Transmitters, as currently set (''as is''), meetmore » the Class 1 criteria. Several of the Mini MILES Small Arms Transmitters did not. These were modified and re-tested and now meet the Class 1 laser hazard criteria. All but one System Controllers (hand held and rifle stock) met class 1 criteria for single trigger pulls and all presented Class 3a laser hazard levels if the trigger is held (continuous emission) for more than 5 seconds on a single point target. All units were Class 3a for ''aided'' viewing. These units were modified and re-tested and now meet the Class 1 hazard criteria for both ''aided'' as well as ''unaided'' viewing. All the Claymore Mine laser emitters tested are laser hazard Class 1 for both ''aided'' as well as ''unaided'' viewing.« less

  19. NGSLR Safety Handbook

    NASA Technical Reports Server (NTRS)

    McGarry, Jan

    2015-01-01

    NASA's Next Generation Satellite Laser Ranging (NGSLR) station is the prototype for NASA's Satellite Laser Ranging (SLR) systems which will be deployed around the world in the coming decade. The NGSLR system will be an autonomous, photon-counting SLR station with an expected absolute range accuracy of better than one centimeter and a normal point (time-averaged) range precision better than one millimeter. The system provides continuous (weather permitting), 24 hour tracking coverage to an existing constellation of approximately two dozen artificial satellites equipped with passive retroreflector arrays, using pulsed, 532 nm, class IV laser systems. Current details on the approved laser systems can be found in the Appendix 1 of this document. This safety plan addresses the potential hazards to emitted laser radiation, which can occur both inside and outside the shelter. Hazards within the shelter are mitigated through posted warning signs, activated warning lights, procedural controls, personal protective equipment (PPE), laser curtains, beam blocking systems, interlock controls, pre-configured laser control settings, and other controls discussed in this document. Since the NGSLR is a satellite tracking system, laser hazards exist outside the shelter to personnel on the shelter roof and to passing aircraft. Potential exposure to personnel outside the system is mitigated through the use of posted warning signs, access control, procedural controls, a stairwell interlock, beam attenuation/blocking devices, and a radar based aircraft detection system.

  20. LATEST LASER AND LIGHT-BASED ADVANCES FOR ETHNIC SKIN REJUVENATION

    PubMed Central

    Elsaie, Mohamed Lotfy; Lloyd, Heather Woolery

    2008-01-01

    Background: Advances in nonablative skin rejuvenation technologies have sparked a renewed interest in the cosmetic treatment of aging skin. More options exist now than ever before to reverse cutaneous changes caused by long-term exposure to sunlight. Although Caucasian skin is more prone to ultraviolet light injury, ethnic skin (typically classified as types IV to VI) also exhibits characteristic photoaging changes. Widespread belief that inevitable or irreversible textural changes or dyspigmentation occurs following laser- or light-based treatments, has been challenged in recent years by new classes of devices capable of protecting the epidermis from injury during treatment. Objective: The purpose of this article is to review recent clinical advances in the treatment of photoaging changes in ethnic skin. This article provides a basis for the classification of current advances in nonablative management of ethnic skin. PMID:19881986

  1. Noise and Chaos in Driven Josephson Junctions

    DTIC Science & Technology

    1987-03-01

    be physically close to some noisy equipment such as a CO2 laser containing an electric discharge and the laser power supply . So we have to try to...regions. The agreement is very good in some of the quanti- tative comparisons such as the step width dependence on the laser power . The simulations...discovered that the noisy I-V curves are caused I various nonlinear dynamic effects. There are I-V curves irradiated at certain laser power levels

  2. A retrospective chart review to assess the safety of nonablative fractional laser resurfacing in Fitzpatrick skin types IV to VI.

    PubMed

    Clark, Charlotte M; Silverberg, Jonathan I; Alexis, Andrew F

    2013-04-01

    Laser resurfacing in patients with Fitzpatrick skin phototypes (SPT) IV to VI is associated with a higher risk of pigmentary alteration. There is a paucity of studies evaluating optimum treatment parameters for fractional lasers in darkly pigmented skin types. This is a retrospective review of medical records for patients with SPT IV to VI who were treated with a 1,550 nm erbium-doped fractional nonablative laser (Fraxel Re:Store SR 1550; Solta Medical, Hayword, CA). Data were collected from patient charts and the clinic laser logbook from January 2008 to January 2012. The frequency of treatment-associated postinflammatory hyperpigmentation (PIH) and treatment settings used were evaluated. A total of 115 total laser sessions (45 patients) were included in our analysis. Five of the sessions (4%) were accompanied by PIH, 2 of which occurred in a single patient. Only 1 episode of PIH lasted longer than 1 month (2 months). Two of the 5 cases had only transient PIH (≤7 days), one of which was reported by the patient and not clinically evident on examination. The 1,550 nm erbium-doped fractional laser is well tolerated in SPT IV to VI. Fractional laser resurfacing, with the settings used and pretreatment and posttreatment hydroquinone 4% cream, was associated with a low risk of PIH in darker skin types.

  3. SEM Evaluation of Enamel Surface Changes and Enamel Microhardness around Orthodontic Brackets after Application of CO2 Laser, Er,Cr:YSGG Laser and Fluoride Varnish: An In vivo Study.

    PubMed

    Kaur, Tarundeep; Tripathi, Tulika; Rai, Priyank; Kanase, Anup

    2017-09-01

    One of the most undesirable consequences of orthodontic treatment is occurrence of enamel demineralization around orthodontic brackets. Numerous in vitro studies have reported the prevention of enamel demineralization by surface treatment with lasers and fluoride varnish. To evaluate the changes on the enamel surface and microhardness around orthodontic brackets after surface treatment by CO 2 laser, Er, Cr:YSGG laser and fluoride varnish in vivo. A double blind interventional study was carried out on 100 premolars which were equally divided into five groups, out of which one was the control group (Group 0). The intervention groups (Group I to IV) comprised of patients requiring fixed orthodontic treatment with all 4 first premolars extraction. Brackets were bonded on all 80 premolars which were to be extracted. Enamel surface treatment of Groups I, II and III was done by CO 2 laser, Er, Cr:YSGG laser and 5% sodium fluoride varnish respectively and Group IV did not receive any surface treatment. A modified T-loop was ligated to the bracket and after two months, the premolars were extracted. Surface changes were evaluated by Scanning Electron Microscopic (SEM) and microhardness testing. Comparison of mean microhardness between all the groups was assessed using post-hoc test with Bonferroni correction. Group I showed a melted enamel appearance with fine cracks and fissures while Group II showed a glossy, homogenous enamel surface with well coalesced enamel rods. Group III showed slight areas of erosions and Group IV presented areas of stripped enamel. Significant difference was observed between the mean microhardness (VHN) of Group I, Group II, Group III, Group IV and Group 0 with p<0.001. A significant difference of p<0.001 was observed while comparing Group I vs II,III,IV,0 and Group II vs III,IV,0. However, difference while comparing Group III vs IV was p=0.005 and difference between the mean microhardness of Group 0 vs Group III was non significant. Surface treatment with Er,Cr:YSGG laser causes a positive alteration of the enamel surface increasing its ability to resist demineralization with optimum microhardness as compared to CO 2 laser and sodium fluoride varnish.

  4. 40 CFR 147.650 - State-administrative program-Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CONTROL PROGRAMS Idaho § 147.650 State-administrative program—Class I, II, III, IV, and V wells. The UIC program for Class I, II, III, IV, and V wells in the State of Idaho, other than those on Indian lands, is the program administered by the Idaho Department of Water Resources, approved by EPA pursuant to...

  5. Modified Laser and Thermos cell calculations on microcomputers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shapiro, A.; Huria, H.C.

    1987-01-01

    In the course of designing and operating nuclear reactors, many fuel pin cell calculations are required to obtain homogenized cell cross sections as a function of burnup. In the interest of convenience and cost, it would be very desirable to be able to make such calculations on microcomputers. In addition, such a microcomputer code would be very helpful for educational course work in reactor computations. To establish the feasibility of making detailed cell calculations on a microcomputer, a mainframe cell code was compiled and run on a microcomputer. The computer code Laser, originally written in Fortran IV for the IBM-7090more » class of mainframe computers, is a cylindrical, one-dimensional, multigroup lattice cell program that includes burnup. It is based on the MUFT code for epithermal and fast group calculations, and Thermos for the thermal calculations. There are 50 fast and epithermal groups and 35 thermal groups. Resonances are calculated assuming a homogeneous system and then corrected for self-shielding, Dancoff, and Doppler by self-shielding factors. The Laser code was converted to run on a microcomputer. In addition, the Thermos portion of Laser was extracted and compiled separately to have available a stand alone thermal code.« less

  6. Investigation into the Emerging Role of the Basic Amino Acid L-Lysine in Enhancing Solubility and Permeability of BCS Class II and BCS Class IV Drugs.

    PubMed

    Abdelkader, Hamdy; Fathalla, Zeinab

    2018-06-18

    The search for a simple and scalable approach that can improve the two key biopharmaceutical processes (solubility and permeability) for BCS Class II and BCS Class IV has still been unmet need. In this study, L-lysine was investigated as a potential excipient to tackle problems with solubility and permeability. Bendazac (Class II); quercetin and rutin (Class IV) were employed. Drugs-lysine complexes in 1:1 M ratios were prepared by co-precipitation and co-grinding; characterized for solubility, partition coefficient, DSC, FTIR, SEM, dissolution rate and permeability. Chemical stability of quercetin-lysine and rutin-lysine was studied by assessing antioxidant capacity using Trolox and CUPRAC assays. Drugs-lysine salt/complexes were confirmed. Solubility enhancement factors ranged from 68- to 433-fold increases and dissolution rates were also significantly enhanced by up to 6-times, compared with drugs alone. With the exception of rutin-lysine, P app for bendazac-lysine and quercetin-lysine enhanced by 2.3- to 4-fold. P app for quercetin (Class IV) benefited more than bendazac (Class II) when complexed with lysine. This study warrants the use of L-lysine as a promising excipient for enhanced solubility and permeability of Class II and Class IV, providing that the solubility of the drug is ensured at 'the door step' of absorption sites.

  7. Comparative scanning electron microscope analysis of diode laser and desensitizing toothpastes for evaluation of efficacy of dentinal tubular occlusion.

    PubMed

    Reddy, Guntakala Vikram; Akula, Sushma; Malgikar, Suryakanth; Babu, Palaparthy Raja; Reddy, Gooty Jagadish; Josephin, Johnson Juliet

    2017-01-01

    The present study aims to evaluate the efficacy of diode laser alone and in combination with desensitizing toothpastes in occluding dentinal tubules (both partially occluded and completely occluded tubules) by scanning electron microscope (SEM). Fifty human teeth were extracted, cervical cavities were prepared and etched with 17% ethylenediaminetetraacetic acid, and smear layer was removed to expose the tubules. The teeth were divided into five groups: Group I - Application of NovaMin-formulated toothpaste, Group II - Application of Pro-Argin ™ -formulated toothpaste, Group III - Application of diode laser in noncontact mode, Group IV - NovaMin-formulated toothpaste followed by laser irradiation, and Group V - Pro-Argin ™ -formulated toothpaste followed by laser irradiation. After treatment, quantitative analysis of occluded dentinal tubules was done by SEM analysis. The mean values of percentages of total occlusion of dentinal tubules in Groups I, II, III, IV, and V were 92.73% ± 1.38, 90.67% ± 1.86, 96.57% ± 0.64, 97.3% ± 0.68, and 96.9% ± 6.08, respectively. Addition of diode laser (Groups III, IV, and V) yielded a significant occlusion of the dentinal tubules when compared to desensitizing toothpastes alone (Groups I and II). Diode laser (Group III) has shown more efficacy in occluding dentinal tubules when compared with desensitizing toothpastes which was statistically significant ( P < 0.05). Among the five groups, NovaMin + diode laser (Group IV) showed the highest percentage of occluded dentinal tubules.

  8. 40 CFR 147.2200 - State-administered program-Class I, III, IV, and V wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the in situ combustion of coal are regulated by the Rail Road Commission of Texas under a separate UIC... program for Class I, III, IV, and V wells in the State of Texas, except for those wells on Indian lands... (SDWA). Notice of the original approval for Class I, III, IV, and V wells was published in the Federal...

  9. 40 CFR 147.2200 - State-administered program-Class I, III, IV, and V wells.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the in situ combustion of coal are regulated by the Rail Road Commission of Texas under a separate UIC... program for Class I, III, IV, and V wells in the State of Texas, except for those wells on Indian lands... (SDWA). Notice of the original approval for Class I, III, IV, and V wells was published in the Federal...

  10. [Unintended cooling, active warming, and microcirculation in cardiosurgical patients].

    PubMed

    Aksel'rod, B A; Trekova, N A; Guleshov, V A; Tolstova, I A; Gus'kov, D A; Babaev, M A

    2010-01-01

    The study was undertaken to compare various methods to maintain a patient's body temperature and to evaluate their impact on microcirculation during myocardial revascularization under normothermal extracorporeal circulation (NTEC). The study enrolled 50 patients with NYHA Functional Classes III-IV coronary heart disease, who underwent aortocoronary bypass surgery under NTEC. A HICO-AQUATHERM 660 water-warming unit (Hirtz, Germany) was used in Group 1 patients (n=30). A Bair Hugger air-warming unit (Arizant, U.S.A.) with a mattress located under a patient was employed in Group 2 (n=20). Intraoperative microcirculation monitoring was carried out by a laser analyzer (Lazma, Moscow).

  11. Class IV polyhydroxyalkanoate (PHA) synthases and PHA-producing Bacillus.

    PubMed

    Tsuge, Takeharu; Hyakutake, Manami; Mizuno, Kouhei

    2015-08-01

    This review highlights the recent investigations of class IV polyhydroxyalkanoate (PHA) synthases, the newest classification of PHA synthases. Class IV synthases are prevalent in organisms of the Bacillus genus and are composed of a catalytic subunit PhaC (approximately 40 kDa), which has a PhaC box sequence ([GS]-X-C-X-[GA]-G) at the active site, and a second subunit PhaR (approximately 20 kDa). The representative PHA-producing Bacillus strains are Bacillus megaterium and Bacillus cereus; the nucleotide sequence of phaC and the genetic organization of the PHA biosynthesis gene locus are somewhat different between these two strains. It is generally considered that class IV synthases favor short-chain-length monomers such as 3-hydroxybutyrate (C4) and 3-hydroxyvalerate (C5) for polymerization, but can polymerize some unusual monomers as minor components. In Escherichia coli expressing PhaRC from B. cereus YB-4, the biosynthesized PHA undergoes synthase-catalyzed alcoholytic cleavage using endogenous and exogenous alcohols. This alcoholysis is thought to be shared among class IV synthases, and this reaction is useful not only for the regulation of PHA molecular weight but also for the modification of the PHA carboxy terminus. The novel properties of class IV synthases will open up the possibility for the design of new PHA materials.

  12. Nutrient-dependent increased dendritic arborization of somatosensory neurons.

    PubMed

    Watanabe, Kaori; Furumizo, Yuki; Usui, Tadao; Hattori, Yukako; Uemura, Tadashi

    2017-01-01

    Suboptimal nutrition imposes developmental constraints on infant animals, which marshal adaptive responses to eventually become mature adults. Such responses are mounted at multiple levels from systemic to cellular. At the cellular level, the underlying mechanisms of cell proliferation control have been intensively studied. However, less is known about how growth of postmitotic and morphologically complex cells, such as neurons, is controlled by nutritional status. We address this question using Class I and Class IV dendritic arborization neurons in Drosophila larvae. Class IV neurons have been shown to sense nociceptive thermal, mechanical and light stimuli, whereas Class I neurons are proprioceptors. We reared larvae on diets with different protein and carbohydrate content throughout larval stages and examined how morphologies of Class I or Class IV neurons were affected. Dendritic arbors of Class IV neurons became more complex when larvae were reared on a low-yeast diet, which contains lower amounts of amino acids and other ingredients, compared to a high-yeast diet. In contrast, such low-yeast-dependent hyperarborization was not seen in Class I neurons. The physiological and metabolic implications of the hyperarborization phenotype are discussed in relation to a recent hypothesis that Class IV neurons sense protein-deficient stress and to our characterization of how the dietary yeast contents impacted larval metabolism. © 2016 Molecular Biology Society of Japan and John Wiley & Sons Australia, Ltd.

  13. Transforming Growth Factor-Beta Inhibition Reduces Progression of Early Choroidal Neovascularization Lesions in Rats: P17 and P144 Peptides

    PubMed Central

    Zarranz-Ventura, Javier; Fernández-Robredo, Patricia; Recalde, Sergio; Salinas-Alamán, Angel; Borrás-Cuesta, Francisco; Dotor, Javier; García-Layana, Alfredo

    2013-01-01

    The purpose of this study was to assess the effects of transforming growth factor beta (TGF-β) inhibitor peptides (P17 & P144) on early laser-induced choroidal neovascularization (LI-CNV) lesions in rats, two weeks after laser CNV induction. Seventy-one Long Evans rats underwent diode laser application in an established LI-CNV model. Baseline fluorescein angiography (FA) was performed 14 days following laser procedure, and treatments were administered 16 days post-laser application via different administration routes. Intravenous groups included control (IV-Control), P17 (IV-17), and P144 (IV-144) groups, whereas intravitreal groups included P17 (IVT-17), P144 (IVT-144), and a mixture of both peptides (IVT-17+144) (with fellow eyes receiving vehicle alone). CNV evolution was assessed using FA performed weekly for four weeks after treatment. Following sacrifice, VEGF, TGF-β, COX-2, IGF-1, PAI-1, IL-6, MMP-2, MMP-9, and TNF-α gene expression was assessed using RT-PCR. VEGF and p-SMAD2 protein levels were also assessed by western-blot, while MMP-2 activity was assessed with gelatin zymography. Regarding the FA analysis, the mean CNV area was lower from the 3rd week in IVT-17 and IVT-144 groups, and also from the 2nd week in IVT-17+144. Biochemical analysis revealed that gene expression was lower for VEGF and COX-2 genes in IV-17 and IV-144 groups, VEGF gene in IVT-17+144 group and MMP-2 gene in IVT-17 and IVT-144 groups. VEGF protein expression was also decreased in IV-17, IV-144, IVT-17 and IVT-144, whereas pSMAD-2 levels were lower in IV-17, IV-144 and IVT-17+144 groups. Zymogram analysis revealed decreased MMP-2 activity in IV-17, IV-144, IVT-17 and IVT-144 groups. These data suggest that the use of TGF-β inhibitor peptides (P17 & P144) decrease the development of early CNV lesions by targeting different mediators than those typically affected using current anti-angiogenic therapies. Its potential role in the treatment of early CNV appears promising as a single therapy or adjuvant to anti-VEGF drugs. PMID:23741494

  14. Comparative scanning electron microscope analysis of diode laser and desensitizing toothpastes for evaluation of efficacy of dentinal tubular occlusion

    PubMed Central

    Reddy, Guntakala Vikram; Akula, Sushma; Malgikar, Suryakanth; Babu, Palaparthy Raja; Reddy, Gooty Jagadish; Josephin, Johnson Juliet

    2017-01-01

    Background: The present study aims to evaluate the efficacy of diode laser alone and in combination with desensitizing toothpastes in occluding dentinal tubules (both partially occluded and completely occluded tubules) by scanning electron microscope (SEM). Materials and Methods: Fifty human teeth were extracted, cervical cavities were prepared and etched with 17% ethylenediaminetetraacetic acid, and smear layer was removed to expose the tubules. The teeth were divided into five groups: Group I – Application of NovaMin-formulated toothpaste, Group II – Application of Pro-Argin™-formulated toothpaste, Group III – Application of diode laser in noncontact mode, Group IV – NovaMin-formulated toothpaste followed by laser irradiation, and Group V – Pro-Argin™-formulated toothpaste followed by laser irradiation. After treatment, quantitative analysis of occluded dentinal tubules was done by SEM analysis. Results: The mean values of percentages of total occlusion of dentinal tubules in Groups I, II, III, IV, and V were 92.73% ± 1.38, 90.67% ± 1.86, 96.57% ± 0.64, 97.3% ± 0.68, and 96.9% ± 6.08, respectively. Addition of diode laser (Groups III, IV, and V) yielded a significant occlusion of the dentinal tubules when compared to desensitizing toothpastes alone (Groups I and II). Conclusion: Diode laser (Group III) has shown more efficacy in occluding dentinal tubules when compared with desensitizing toothpastes which was statistically significant (P < 0.05). Among the five groups, NovaMin + diode laser (Group IV) showed the highest percentage of occluded dentinal tubules. PMID:29398853

  15. Nonablative Fractional Laser Resurfacing for Acne Scarring in Patients With Fitzpatrick Skin Phototypes IV-VI.

    PubMed

    Alexis, Andrew F; Coley, Marcelyn K; Nijhawan, Rajiv I; Luke, Janiene D; Shah, Sejal K; Argobi, Yahya A; Nodzenski, Michael; Veledar, Emir; Alam, Murad

    2016-03-01

    There is a paucity of studies investigating laser resurfacing in Fitzpatrick skin phototypes (SPT) IV to VI. To assess the efficacy and safety of fractional nonablative laser resurfacing in the treatment of acne scarring in patients with SPT IV to VI. The authors conducted a randomized, investigator-blinded and rater-blinded, split-face comparative study of adults with SPT IV to VI and facial acne scars treated with 2 different density settings and the same fluence. Quantitative global scarring grading system (QGSGS) scores were significantly improved from baseline at 16 and 24 weeks (p = .0277). Improvements in QGSGS scores after higher and lower density treatments were statistically similar (p = .96). The live-blinded dermatologist, the blinded dermatologist photoraters, and the patients rated scars as being significantly more improved by visual analog scale at weeks 16 and 24 compared with baseline (p < .001) for both treatment densities. Five of 7 and 3 of 7 patients in the higher and lower density group, respectively, experienced mild or moderate hyperpigmentation as an investigator observed site reaction. The nonablative 1550-nm fractional laser is safe and efficacious in treating acne scaring in Fitzpatrick skin types IV to VI. Self-limited postinflammatory hyperpigmentation was a common occurrence, especially with higher treatment densities.

  16. [Preoperative risk assessment with the ASA classification. A prospective study of morbidity and mortality in various ASA classes in 2,937 patients in general surgery].

    PubMed

    Menke, H; John, K D; Klein, A; Lorenz, W; Junginger, T

    1992-12-01

    The value of ASA classification in assessment of perioperative risk, i.e. especially postoperative morbidity, was analyzed prospectively using the data of 2937 patients. The analysis took into account the criteria validity, reliability, and sensitivity. The incidence of post-operative morbidity after elective surgery rose from 3.9% in ASA class I to 36% in ASA class IV. Mortality was 0.6% in ASA class II, whereas 9.3% died in ASA class IV. Morbidity, mortality respectively, after emergency surgery was 10.2% in ASA class II compared to 69% in class IV, mortality 1.4% compared to 21.5%. Differences between the ASA classes were confirmed (p-value < 0.05) considering separate kinds of complications and different periods. Furthermore, ASA classification was a valuable reference to length of stay and severity of necessary therapy at the ICU.

  17. 40 CFR 147.251 - EPA-administered program-Class I, III, IV and V wells and Indian lands.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., IV and V wells and Indian lands. 147.251 Section 147.251 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS California § 147.251 EPA-administered program—Class I, III, IV and V wells and...

  18. 40 CFR 147.301 - EPA-administered program-Class I, III, IV, V wells and Indian lands.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., IV, V wells and Indian lands. 147.301 Section 147.301 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Colorado § 147.301 EPA-administered program—Class I, III, IV, V wells and Indian...

  19. 40 CFR 147.251 - EPA-administered program-Class I, III, IV and V wells and Indian lands.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., IV and V wells and Indian lands. 147.251 Section 147.251 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS California § 147.251 EPA-administered program—Class I, III, IV and V wells and...

  20. 40 CFR 147.301 - EPA-administered program-Class I, III, IV, V wells and Indian lands.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., IV, V wells and Indian lands. 147.301 Section 147.301 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Colorado § 147.301 EPA-administered program—Class I, III, IV, V wells and Indian...

  1. 40 CFR 146.10 - Plugging and abandoning Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) The plugging and abandonment plan required in 40 CFR 144.51(o) and 144.52(a)(6) shall, in the case of... deems it necessary and feasible to insure adequate protection of USDWs. (b) Requirements for Class IV... with 40 CFR 144.23(b). (c) Requirements for Class V wells. (1) Prior to abandoning a Class V well, the...

  2. 40 CFR 146.10 - Plugging and abandoning Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) The plugging and abandonment plan required in 40 CFR 144.51(o) and 144.52(a)(6) shall, in the case of... deems it necessary and feasible to insure adequate protection of USDWs. (b) Requirements for Class IV... with 40 CFR 144.23(b). (c) Requirements for Class V wells. (1) Prior to abandoning a Class V well, the...

  3. 40 CFR 146.10 - Plugging and abandoning Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) The plugging and abandonment plan required in 40 CFR 144.51(o) and 144.52(a)(6) shall, in the case of... deems it necessary and feasible to insure adequate protection of USDWs. (b) Requirements for Class IV... with 40 CFR 144.23(b). (c) Requirements for Class V wells. (1) Prior to abandoning a Class V well, the...

  4. Bond Strength of Gold Alloys Laser Welded to Cobalt-Chromium Alloy

    PubMed Central

    Watanabe, Ikuya; Wallace, Cameron

    2008-01-01

    The objective of this study was to investigate the joint properties between cast gold alloys and Co-Cr alloy laser-welded by Nd:YAG laser. Cast plates were fabricated from three types of gold alloys (Type IV, Type II and low-gold) and a Co-Cr alloy. Each gold alloy was laser-welded to Co-Cr using a dental laser-welding machine. Homogeneously-welded and non-welded control specimens were also prepared. Tensile testing was conducted and data were statistically analyzed using ANOVA. The homogeneously-welded groups showed inferior fracture load compared to corresponding control groups, except for Co-Cr. In the specimens welded heterogeneously to Co-Cr, Type IV was the greatest, followed by low-gold and Type II. There was no statistical difference (P<0.05) in fracture load between Type II control and that welded to Co-Cr. Higher elongations were obtained for Type II in all conditions, whereas the lowest elongation occurred for low-gold welded to Co-Cr. This study indicated that, of the three gold alloys tested, the Type IV gold alloy was the most suitable alloy for laser-welding to Co-Cr. PMID:19088892

  5. In vitro bond strength of an epoxy resin-based root canal sealer to root dentin irradiated with high-power lasers and adhesive interface analyses.

    PubMed

    Araujo, Vanessa Lessa C; Cruvinel, Pedro Basto; Palma-Dibb, Regina Guenka; Gariba-Silva, Ricardo

    2018-02-01

    The aim of this study was to evaluate in vitro the influence of high-power lasers (Nd:YAG and diode 980 nm) associated with mineral coal as fotopotencializer on bond strength of an epoxy resin-based root canal sealer to root dentin, using the pushout test, and on the dentin/filling material interface, using confocal laser microscopy. For this purposes, 50 canines were instrumented with Mtwo rotary system up to #50.04 instrument and randomly assigned to five groups (n = 10): group I-control EDTAC; group II-EDTAC and Nd:YAG laser; group III-EDTAC and diode laser 980 nm; group IV-EDTAC, Nd:YAG laser and mineral coal 5 g/100 mL; and group V-EDTAC, diode laser 980 nm and mineral coal 5 g/100 mL. All data were analyzed by ANOVA (at 5% significance level) following the Kruskal-Wallis, Dunn and Tukey tests. The group I increased more bond strength of the sealer to root dentin that treated with only EDTAC 17% (17.21 ± 21.75 MPa), similar to the group II (12.21 ± 18.20 MPa) and group IV (14.92 ± 28.06 MPa), both treated with Nd:YAG laser, with the exception of group IV, which was added to mineral coal. The group V (8.75 ± 13.42 MPa) had similar results to the groups II and IV, but the same similarity were found when compared with group III (7.11 + 11.28 MPa), with lower results. Regarding the root thirds, the apical third (23.27 ± 29.21 MPa) presented a statistically higher value on bond strength than the cervical third (5.92 ± 5.33 MPa) and middle third (6.93 ± 7, 11 MPa) (p > 0.05). Group II (86.27 μm) showed the highest tags penetration values, with a statistically difference to the group III (51.57 μm), IV (36.77 μm) and V (32.37 μm) (p < 0.05). Group I (71.63 μm) was statistically similar to groups II and III (p > 0.05). Group IV had the lowest values and was statistically similarity to groups III and V (p > 0.05). It was concluded that the treatment with Nd:YAG laser provides better results than the diode 980 nm laser, except when was added mineral coal. The control and diode 980 nm laser groups presented less adhesive failures and more mists failures than the other groups. Both lasers did not interfere negatively compared to the control group.

  6. Comparison of adverse events of laser and light-assisted hair removal systems in skin types IV-VI.

    PubMed

    Breadon, Jonith Y; Barnes, Chad A

    2007-01-01

    Photoepilation, utilizing lasers and noncoherent light sources, is designed to irradiate as much of the follicular unit as possible, with melanin as the target chromophore. Wavelength absorption should generate energy sufficient to heat and destroy the hair follicle, while preserving the surrounding tissue. When performing photoepilation on African-American skin (Fitzpatrick skin types IV-VI) a greater risk of potential epidermal adverse events, such as dyspigmentation, blistering, crusting, edema, and subsequent scarring, is possible. To reduce epidermal melanin absorption of energy longer wavelengths are considered safer for use on Fitzpatrick skin types IV to VI. This article reviews and compares the reported incidences of adverse events in African-American skin, utilizing lasers and noncoherent light sources for assisted hair removal.

  7. Effects of Flow and Non-Newtonian Fluids on Nonspherical Cavitation Bubbles,

    DTIC Science & Technology

    1983-04-10

    54 10 Alteration of Streamlines by Sphere for Y2 (8.*). 55 11 Major Components of Optical Cavitation. 61 12 Arrangement of Apparatus. 62 13 Laser ...341small" expansion parameter 111.12 Cnj C external flow time constant (t -c 0) WAS1 o spherical coordinate cone angle a f laser focal angle Figure 13...11.2 Dj - D external flow variable IV.22 Dbeam effective laser beau diameter V.1 De Deborah number Table 5 Ce, e, , e strain rates IV.8-9 Or* •e

  8. 40 CFR 147.2650 - State-administered program-Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CONTROL PROGRAMS Puerto Rico § 147.2650 State-administered program—Class I, II, III, IV, and V wells. The Underground Injection Control Program for all classes of wells in the Commonwealth of Puerto Rico, other than those on Indian lands, is the program administered by Puerto Rico's Environmental Quality Board (EQB...

  9. 40 CFR 147.2650 - State-administered program-Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROL PROGRAMS Puerto Rico § 147.2650 State-administered program—Class I, II, III, IV, and V wells. The Underground Injection Control Program for all classes of wells in the Commonwealth of Puerto Rico, other than those on Indian lands, is the program administered by Puerto Rico's Environmental Quality Board (EQB...

  10. 40 CFR 147.2650 - State-administered program-Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CONTROL PROGRAMS Puerto Rico § 147.2650 State-administered program—Class I, II, III, IV, and V wells. The Underground Injection Control Program for all classes of wells in the Commonwealth of Puerto Rico, other than those on Indian lands, is the program administered by Puerto Rico's Environmental Quality Board (EQB...

  11. The first crystal structures of a family 19 class IV chitinase: the enzyme from Norway spruce.

    PubMed

    Ubhayasekera, Wimal; Rawat, Reetika; Ho, Sharon Wing Tak; Wiweger, Malgorzata; Von Arnold, Sara; Chye, Mee-Len; Mowbray, Sherry L

    2009-10-01

    Chitinases help plants defend themselves against fungal attack, and play roles in other processes, including development. The catalytic modules of most plant chitinases belong to glycoside hydrolase family 19. We report here x-ray structures of such a module from a Norway spruce enzyme, the first for any family 19 class IV chitinase. The bi-lobed structure has a wide cleft lined by conserved residues; the most interesting for catalysis are Glu113, the proton donor, and Glu122, believed to be a general base that activate a catalytic water molecule. Comparisons to class I and II enzymes show that loop deletions in the class IV proteins make the catalytic cleft shorter and wider; from modeling studies, it is predicted that only three N-acetylglucosamine-binding subsites exist in class IV. Further, the structural comparisons suggest that the family 19 enzymes become more closed on substrate binding. Attempts to solve the structure of the complete protein including the associated chitin-binding module failed, however, modeling studies based on close relatives indicate that the binding module recognizes at most three N-acetylglucosamine units. The combined results suggest that the class IV enzymes are optimized for shorter substrates than the class I and II enzymes, or alternatively, that they are better suited for action on substrates where only small regions of chitin chain are accessible. Intact spruce chitinase is shown to possess antifungal activity, which requires the binding module; removing this module had no effect on measured chitinase activity.

  12. Treatment of melasma with low fluence, large spot size, 1064-nm Q-switched neodymium-doped yttrium aluminum garnet (Nd:YAG) laser for the treatment of melasma in Fitzpatrick skin types II-IV.

    PubMed

    Brown, Alia S; Hussain, Mussarat; Goldberg, David J

    2011-12-01

    Melasma is a common condition affecting over six million American women. Treatment of dermal or combined melasma is difficult and does not respond well to conventional topical therapies. Various light sources have been used recently in the treatment of melasma including fractionated ablative and non-ablative lasers as well as intense pulse light. We report the use of low fluence, large spot size Q-switched, Nd:Yag laser for the treatment of melasma in skin types II-IV.

  13. Laser Applications in Microelectronic and Optoelectronic Manufacturing IV

    DTIC Science & Technology

    1999-07-15

    laser irradiation of the clusters with 6000 laser pulses of X...insulating ma- terials during and after irradiation by tunable, ultrashort pulses from a mid-infrared laser . The three salient examples we con- sider...with ultrashort pulses re- sembles the rear-side ablation seen in irradiation of calcite by Nd:YAG lasers (1064 nm), while the off-resonance FEL

  14. Laser Induced Electrodeposition on Polyimide and GaAs Substrates

    DTIC Science & Technology

    1983-10-01

    6 3.1 Laser Gold Plating on Undoped Ga As Substrate ........... 6 3.1.1 Deposit Formation...22 iv LIST OF ILLUSTRATIONS Figure Page 1. Experimental Set-Up . . . . . .................. 4 2. Laser Gold Pla’ting Undoped GaAs (100...9 3. Laser Gold Plating Undoped GaAs (100) Deposit Resistance Measurement ......................... .10 4. Laser Gold Plating on Polyimide

  15. Laser and Light Treatments for Hair Reduction in Fitzpatrick Skin Types IV-VI: A Comprehensive Review of the Literature.

    PubMed

    Fayne, Rachel A; Perper, Marina; Eber, Ariel E; Aldahan, Adam S; Nouri, Keyvan

    2018-04-01

    Unwanted facial and body hair presents as a common finding in many patients, such as females with hirsutism. With advances in laser and light technology, a clinically significant reduction in hair can be achieved in patients with light skin. However, in patients with darker skin, Fitzpatrick skin types (FST) IV-VI, the higher melanin content of the skin interferes with the proposed mechanism of laser-induced selective photothermolysis, which is to target the melanin in the hair follicle to cause permanent destruction of hair bulge stem cells. Many prospective and retrospective studies have been conducted with laser and light hair-removal devices, but most exclude patients with darkly pigmented skin, considering them a high-risk group for unwanted side effects, including pigmentation changes, blisters, and crust formation. We reviewed the published literature to obtain studies that focused on hair reduction for darker skin types. The existing literature for this patient population identifies longer wavelengths as a key element of the treatment protocol and indicates neodymium-doped yttrium aluminum garnet (Nd:YAG), diode, alexandrite, and ruby lasers as well as certain intense pulsed light sources for safe hair reduction with minimal side effects in patients with FST IV-VI, so long as energy settings and wavelengths are appropriate. Based on the findings in this review, safe and effective hair reduction for patients with FST IV-VI is achievable under proper treatment protocols and energy settings.

  16. Laser Atherectomy for Treatment of Femoropopliteal In-Stent Restenosis.

    PubMed

    Armstrong, Ehrin J; Thiruvoipati, Thejasvi; Tanganyika, Kundai; Singh, Gagan D; Laird, John R

    2015-08-01

    To investigate if laser atherectomy with adjunctive balloon angioplasty can improve endovascular treatment outcomes for femoropopliteal in-stent restenosis (ISR). A dual center study included 135 symptomatic patients (mean age 71 years; 76 men) who underwent endovascular treatment of femoropopliteal ISR between 2006 and 2013. Of these, 54 (40%) were treated with laser atherectomy and the remaining 81 patients with balloon angioplasty alone. Angiographic images were reviewed for lesion morphology and characteristics, TransAtlantic InterSociety Consensus (TASC) II classification, and distal runoff. Class I ISR was defined as focal lesions ≤50 mm, class II ISR as lesions >50 mm, and class III ISR as stent total occlusion. Recurrent ISR was determined by a peak systolic velocity ratio >2.4 by duplex ultrasound. Patients treated with laser atherectomy had longer mean ISR lesion length (222 vs 114 mm, p<0.001) and more class III ISR (69% vs 20%, p=0.001). There was no association between laser atherectomy and rates of recurrent restenosis or occlusion for patients with class I/II ISR, but there was a significantly lower rate of target lesion revascularization at 2 years among patients treated with laser atherectomy (14% vs 44%, p=0.05). In comparison, patients with class III ISR treated with laser atherectomy had lower rates of recurrent restenosis at 1 year (54% vs 91%, p=0.05) and 2 years (69% vs 100%, p=0.05). Patients with class III ISR treated with laser atherectomy also had lower rates of recurrent in-stent occlusion at 2-year follow-up (33% vs 71%, p=0.04). When used to treat complex ISR, including in-stent occlusions, laser atherectomy with adjunctive balloon angioplasty may be associated with improved patency. © The Author(s) 2015.

  17. Finite element analysis of maxillary bone stress caused by Aramany Class IV obturator prostheses.

    PubMed

    Miyashita, Elcio Ricardo; Mattos, Beatriz Silva Câmara; Noritomi, Pedro Yoshito; Navarro, Hamilton

    2012-05-01

    The retention of an Aramany Class IV removable partial dental prosthesis can be compromised by a lack of support. The biomechanics of this obturator prosthesis result in an unusual stress distribution on the residual maxillary bone. This study evaluated the biomechanics of an Aramany Class IV obturator prosthesis with finite element analysis and a digital 3-dimensional (3-D) model developed from a computed tomography scan; bone stress was evaluated according to the load placed on the prosthesis. A 3-D model of an Aramany Class IV maxillary resection and prosthesis was constructed. This model was used to develop a finite element mesh. A 120 N load was applied to the occlusal and incisal platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis were expressed in MPa. Under posterior load, tensile and compressive stresses were observed; the tensile stress was greater than the compressive stress, regardless of the bone region, and the greatest compressive stress was observed on the anterior palate near the midline. Under an anterior load, tensile stress was observed in all of the evaluated bone regions; the tensile stress was greater than the compressive stress, regardless of the bone region. The Aramany Class IV obturator prosthesis tended to rotate toward the surgical resection when subjected to posterior or anterior loads. The amount of tensile and compressive stress caused by the Aramany Class IV obturator prosthesis did not exceed the physiological limits of the maxillary bone tissue. (J Prosthet Dent 2012;107:336-342). Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  18. 49 CFR 572.127 - Test conditions and instrumentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Forces—Class 1000; (ii) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation—Class 60 (if used). (3) Thorax: (i) Rib acceleration—Class 1000; (ii) Spine and pendulum accelerations—Class...

  19. 49 CFR 572.127 - Test conditions and instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Forces—Class 1000; (ii) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation—Class 60 (if used). (3) Thorax: (i) Rib acceleration—Class 1000; (ii) Spine and pendulum accelerations—Class...

  20. 49 CFR 572.127 - Test conditions and instrumentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Forces—Class 1000; (ii) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation—Class 60 (if used). (3) Thorax: (i) Rib acceleration—Class 1000; (ii) Spine and pendulum accelerations—Class...

  1. 49 CFR 572.127 - Test conditions and instrumentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Forces—Class 1000; (ii) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation—Class 60 (if used). (3) Thorax: (i) Rib acceleration—Class 1000; (ii) Spine and pendulum accelerations—Class...

  2. 49 CFR 572.127 - Test conditions and instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Forces—Class 1000; (ii) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation—Class 60 (if used). (3) Thorax: (i) Rib acceleration—Class 1000; (ii) Spine and pendulum accelerations—Class...

  3. Gain Coupling of Class A Semiconductor Lasers (Postprint)

    DTIC Science & Technology

    2010-09-01

    Circuits (Wiley, 1995). 15. SimuLase Version 1.4.0.0 by Nonlinear Control Strategies, Inc. (2009). 16. A. Siegman , Lasers (University Science, 1986). 3062 OPTICS LETTERS / Vol. 35, No. 18 / September 15, 2010 3 ...AFRL-RY-WP-TP-2010-1250 GAIN COUPLING OF CLASS A SEMICONDUCTOR LASERS (POSTPRINT) Chris Hessenius, Mahmoud Fallahi, and Jerome Moloney...June 2010 4. TITLE AND SUBTITLE GAIN COUPLING OF CLASS A SEMICONDUCTOR LASERS (POSTPRINT) 5a. CONTRACT NUMBER In-house 5b. GRANT NUMBER 5c

  4. 49 CFR 572.146 - Test conditions and instrumentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Head acceleration—Class 1000 (2) Neck (i) Force—Class 1000 (ii) Moments—Class 600 (iii) Pendulum... acceleration—Class 1000 (ii) Spine and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv...

  5. 49 CFR 572.146 - Test conditions and instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Head acceleration—Class 1000 (2) Neck (i) Force—Class 1000 (ii) Moments—Class 600 (iii) Pendulum... acceleration—Class 1000 (ii) Spine and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv...

  6. 49 CFR 572.146 - Test conditions and instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Head acceleration—Class 1000 (2) Neck (i) Force—Class 1000 (ii) Moments—Class 600 (iii) Pendulum... acceleration—Class 1000 (ii) Spine and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv...

  7. 49 CFR 572.146 - Test conditions and instrumentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Head acceleration—Class 1000 (2) Neck (i) Force—Class 1000 (ii) Moments—Class 600 (iii) Pendulum... acceleration—Class 1000 (ii) Spine and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv...

  8. 49 CFR 572.146 - Test conditions and instrumentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Head acceleration—Class 1000 (2) Neck (i) Force—Class 1000 (ii) Moments—Class 600 (iii) Pendulum... acceleration—Class 1000 (ii) Spine and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv...

  9. Lupus nephritis in Lebanon.

    PubMed

    Uthman, I W; Muffarij, A A; Mudawar, W A; Nasr, F W; Masri, A F

    2001-01-01

    This is a retrospective study of the clinicopathological characteristics of 50 systemic lupus erythematosus patients with nephritis who underwent a kidney biopsy and were admitted to the American University of Beirut Medical Center, in Lebanon, between 1979 and 1999. There were 43 females and seven males, with a median age of 24 y. Renal histology slides from these patients were assessed according to the World Health Organization classification, and were distributed as follows: class I (n = 3, 6%); class II (n = 14, 28%); class III (n = 11, 22%); class IV (n = 19, 38%); class V (n = 1, 2%); class VI (n = 2, 4%). All the patients received oral prednisone, in addition the following treatments were used: pulse intravenous (i.v.) cyclophosphamide (n = 23, 46%); azathioprine (n = 22, 44%); pulse i.v. steroids (n = 19, 38%); chloroquine sulfate (n = 17, 34%); methotrexate (n = 5, 10%); and plasmapheresis (n = 2, 4%). The median duration of follow-up was 5 y (range 1-33 y). On their last evaluation, out of 37 patients who were followed, 20 patients (54%) had controlled disease, eight patients (22%) were still on active medical treatment, four patients (11%) were on chronic hemodialysis, and five patients (13%) had died. Unlike three other Arab populations studies from Kuwait, United Arab Emirates and Saudi Arabia, where the most frequent histopathologic abnormality was class III, diffuse proliferative LN (class IV) was the most common type of lupus nephritis in Lebanon, similarly to reports from USA, France, Netherlands, South Africa, Thailand and Taiwan.

  10. IV-VI semiconductor lasers for gas phase biomarker detection

    NASA Astrophysics Data System (ADS)

    McCann, Patrick; Namjou, Khosrow; Roller, Chad; McMillen, Gina; Kamat, Pratyuma

    2007-09-01

    A promising absorption spectroscopy application for mid-IR lasers is exhaled breath analysis where sensitive, selective, and speedy measurement of small gas phase biomarker molecules can be used to diagnose disease and monitor therapies. Many molecules such as nitric oxide, ethane, formaldehyde, acetaldehyde, acetone, carbonyl sulfide, and carbon disulfide have been connected to diseases or conditions such as asthma, oxidative stress, breast cancer, lung cancer, diabetes, organ transplant rejection, and schizophrenia. Measuring these and other, yet to be discovered, biomarker molecules in exhaled breath with mid-IR lasers offers great potential for improving health care since such tests are non-invasive, real-time, and do not require expensive consumables or chemical reagents. Motivated by these potential benefits, mid-IR laser spectrometers equipped with presently available cryogenically-cooled IV-VI lasers mounted in compact Stirling coolers have been developed for clinical research applications. This paper will begin with a description of the development of mid-IR laser instruments and their use in the largest known exhaled breath clinical study ever performed. It will then shift to a description of recent work on the development of new IV-VI semiconductor quantum well materials and laser fabrication methods that offer the promise of low power consumption (i.e. efficient) continuous wave emission at room temperature. Taken together, the demonstration of compelling clinical applications with large market opportunities and the clear identification of a viable pathway to develop low cost mid-IR laser instrumentation can create a renewed focus for future research and development efforts within the mid-IR materials and devices area.

  11. Room Temperature Erbium-Doped Yttrium Vanadate (Er:YVO4) Laser and Amplifier

    DTIC Science & Technology

    2016-09-01

    perpendicular to the laser cavity axis, was pumped in σ-polarization and lased in π-polarization. The laser operated in a quasi -continuous wave regime...laser, amplifier, quasi -continuous wave 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT UU 18. NUMBER OF...distribution unlimited. iii Contents List of Figures iv 1. Introduction 1 2. Laser Experimental Setup and Results 2 3. Laser Amplifier Setup 6 4

  12. Low-intensity infrared laser effects on zymosan-induced articular inflammatory response

    NASA Astrophysics Data System (ADS)

    Januária dos Anjos, Lúcia Mara; da Fonseca, Adenilson d. S.; Gameiro, Jacy; de Paoli, Flávia

    2015-03-01

    Low-level therapy laser is a phototherapy treatment that involves the application of low power light in the red or infrared wavelengths in various diseases such as arthritis. In this work, we investigated whether low-intensity infrared laser therapy could cause death by caspase-6 apoptosis or DNA damage pathways in cartilage cells after zymosaninduced articular inflammatory process. Inflammatory process was induced in C57BL/6 mouse by intra-articular injection of zymosan into rear tibio-tarsal joints. Thirty animals were divided in five groups: (I) control, (II) laser, (III) zymosan-induced, (IV) zymosan-induced + laser and (V). Laser exposure was performed after zymosan administration with low-intensity infrared laser (830 nm), power 10 mW, fluence 3.0 J/cm2 at continuous mode emission, in five doses. Twenty-four hours after last irradiation, the animals were sacrificed and the right joints fixed and demineralized. Morphological analysis was observed by hematoxylin and eosin stain, pro-apoptotic (caspase-6) was analyzed by immunocytochemistry and DNA fragmentation was performed by TUNEL assay in articular cartilage cells. Inflammatory process was observed in connective tissue near to articular cartilage, in IV and V groups, indicating zymosan effect. This process was decreased in both groups after laser treatment and dexamethasone. Although groups III and IV presented higher caspase-6 and DNA fragmentation percentages, statistical differences were not observed when compared to groups I and II. Our results suggest that therapies based on low-intensity infrared lasers could reduce inflammatory process and could not cause death by caspase-6 apoptosis or DNA damage pathways in cartilage cells after zymosan-induced articular inflammatory process.

  13. Pedestal cleaning for high laser pulse contrast ratio with a 100 TW class laser system.

    PubMed

    Fourmaux, S; Payeur, S; Buffechoux, S; Lassonde, P; St-Pierre, C; Martin, F; Kieffer, J C

    2011-04-25

    Laser matter interaction at relativistic intensities using 100 TW class laser systems or higher is becoming more and more widespread. One of the critical issues of such laser systems is to let the laser pulse interact at high intensity with the solid target and avoid any pre-plasma. Thus, a high Laser Pulse Contrast Ratio (LPCR) parameter is of prime importance. We present the LPCR characterization of a high repetition 100 TW class laser system. We demonstrate that the generated Amplified Spontaneous Emission (ASE) degrades the overall LPCR performance. We propose a simple way to clean the pulse after the first amplification stage by introducing a solid state saturable absorber which results in a LPCR improvement to better than 10(10) with only a 30% energy loss at a 10 Hz repetition rate. We finally correlated this cleaning method with experimental results.

  14. Control of Hazards to Health From Laser Radiation

    DTIC Science & Technology

    2006-01-01

    compared to the calculated AEL. (2) Optically aided viewing. Viewing a laser beam with optical aids (other than ordinary eyeglasses or contact lenses ...resonant optical cavity. TB MED 524 8 b. Lenses , mirrors, cooling systems, shutters, and other accessories may be added to the system to obtain...procedures for laser optical systems (for example, mirrors, prisms, and lenses ) that employ Class 2 and Class 3a lasers, it is always good laser safety

  15. 49 CFR 572.137 - Test conditions and instrumentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...—Class 1000 (2) Neck: (i) Forces—Class 1000 (ii) Moments—Class 600 (iii) Pendulum acceleration—Class 180... and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv) Forces—Class 1000 (v...—Class 180 (6) Femur forces and knee pendulum—Class 600 (n) Coordinate signs for instrumentation polarity...

  16. 49 CFR 572.137 - Test conditions and instrumentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...—Class 1000 (2) Neck: (i) Forces—Class 1000 (ii) Moments—Class 600 (iii) Pendulum acceleration—Class 180... and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv) Forces—Class 1000 (v...—Class 180 (6) Femur forces and knee pendulum—Class 600 (n) Coordinate signs for instrumentation polarity...

  17. 49 CFR 572.137 - Test conditions and instrumentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...—Class 1000 (2) Neck: (i) Forces—Class 1000 (ii) Moments—Class 600 (iii) Pendulum acceleration—Class 180... and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv) Forces—Class 1000 (v...—Class 180 (6) Femur forces and knee pendulum—Class 600 (n) Coordinate signs for instrumentation polarity...

  18. 49 CFR 572.137 - Test conditions and instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...—Class 1000 (2) Neck: (i) Forces—Class 1000 (ii) Moments—Class 600 (iii) Pendulum acceleration—Class 180... and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv) Forces—Class 1000 (v...—Class 180 (6) Femur forces and knee pendulum—Class 600 (n) Coordinate signs for instrumentation polarity...

  19. 49 CFR 572.137 - Test conditions and instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...—Class 1000 (2) Neck: (i) Forces—Class 1000 (ii) Moments—Class 600 (iii) Pendulum acceleration—Class 180... and pendulum accelerations—Class 180 (iii) Sternum deflection—Class 600 (iv) Forces—Class 1000 (v...—Class 180 (6) Femur forces and knee pendulum—Class 600 (n) Coordinate signs for instrumentation polarity...

  20. Biochemistry of plant class IV chitinases and fungal chitinase-modifying proteins

    USDA-ARS?s Scientific Manuscript database

    Plant class IV chitinases have 2 domains, a small (3 kDa) amino-terminal domain with homology to carbohydrate binding peptides, and a larger (25 kDa) catalytic domain. The biological function of these chitinases is not known. But it is known that some pathogenic fungi secrete chitinase modifying pro...

  1. Polyglycine hydrolases secreted by Pleosporineae fungi that target the linker region of plant class IV chitinases*

    USDA-ARS?s Scientific Manuscript database

    Chitinase modifying proteins (cmps) are fungal proteases that truncate plant class IV chitinases by cleaving near their amino termini. We previously described Fv-cmp, a fungalysin protease that cleaves a conserved glycine-cysteine bond within the hevein domain. Here we describe a new type of cmp—pol...

  2. Alcoholytic Cleavage of Polyhydroxyalkanoate Chains by Class IV Synthases Induced by Endogenous and Exogenous Ethanol

    PubMed Central

    Hyakutake, Manami; Tomizawa, Satoshi; Mizuno, Kouhei; Abe, Hideki

    2014-01-01

    Polyhydroxyalkanoate (PHA)-producing Bacillus strains express class IV PHA synthase, which is composed of the subunits PhaR and PhaC. Recombinant Escherichia coli expressing PHA synthase from Bacillus cereus strain YB-4 (PhaRCYB-4) showed an unusual reduction of the molecular weight of PHA produced during the stationary phase of growth. Nuclear magnetic resonance analysis of the low-molecular-weight PHA revealed that its carboxy end structure was capped by ethanol, suggesting that the molecular weight reduction was the result of alcoholytic cleavage of PHA chains by PhaRCYB-4 induced by endogenous ethanol. This scission reaction was also induced by exogenous ethanol in both in vivo and in vitro assays. In addition, PhaRCYB-4 was observed to have alcoholysis activity for PHA chains synthesized by other synthases. The PHA synthase from Bacillus megaterium (PhaRCBm) from another subgroup of class IV synthases was also assayed and was shown to have weak alcoholysis activity for PHA chains. These results suggest that class IV synthases may commonly share alcoholysis activity as an inherent feature. PMID:24334666

  3. Home inotropic therapy in advanced heart failure: cost analysis and clinical outcomes.

    PubMed

    Harjai, K J; Mehra, M R; Ventura, H O; Lapeyre, Y M; Murgo, J P; Stapleton, D D; Smart, F W

    1997-11-05

    This study was conducted to assess cost savings and clinical outcomes associated with the use of home i.v. inotropic therapy in patients with advanced (New York Heart Association [NYHA] class IV) heart failure. Retrospective analysis. Tertiary care referral center. Twenty-four patients (13 men, 11 women; age, 61+/-12 years) with left ventricular ejection fraction <30% and heart failure refractory to oral agents required home i.v. inotropic therapy for at least 4 consecutive weeks between May 1994 and April 1996. Inotropic agents used included dobutamine (n=20; dose, 5.0+/-2.2 microg/kg/min) or milrinone (n=7; dose, 0.53+/-0.05 microg/kg/min). Cost of care and clinical outcomes (hospital admissions, length of hospital stay, NYHA functional class) were compared during the period of inotropic therapy (study period) and the immediate preceding period of equal duration (control period). In comparison to the control period, the study period (3.9+/-2.7 months) was associated with a 16% reduction in cost, amounting to a calculated savings of $5,700 per patient or $1,465 per patient per month. Concomitantly, a decrease in the number of hospital admissions from 2.7+/-2.6 to 1.3+/-1.3 (p=0.056) and length of hospital stay from 20.9+/-12.7 to 5.5+/-5.4 days (p=0.0004) was observed with improvement in NYHA functional class from 4.0+/-0.0 to 2.7+/-0.9 (p<0.0001). Eight patients (38%) died after 2.8+/-1.7 months of home i.v. inotropic therapy. Home i.v. inotropic therapy reduces hospital admissions, length of stay, and cost of care and improves functional class in patients with advanced (NYHA class IV) heart failure.

  4. Does stone entrapment with ″Uro-Net″ improve Ho:YAG laser lithotripsy efficiency in percutaneous nephrolithotomy and cystolithopaxy?: an in vitro study.

    PubMed

    Marchini, Giovanni Scala; Rai, Aayushi; De, Shubha; Sarkissian, Carl; Monga, Manoj

    2013-01-01

    to test the effect of stone entrapment on laser lithotripsy efficiency. Spherical stone phantoms were created using the BegoStone® plaster. Lithotripsy of one stone (1.0 g) per test jar was performed with Ho:YAG laser (365 µm fiber; 1 minute/trial). Four laser settings were tested: I-0.8 J,8 Hz; II-0.2J,50 Hz; III-0.5 J,50 Hz; IV-1.5 J,40 Hz. Uro-Net (US Endoscopy) deployment was used in 3/9 trials. Post-treatment, stone fragments were strained though a 1mm sieve; after a 7-day drying period fragments and unfragmented stone were weighed. Uro-Net nylon mesh and wire frame resistance were tested (laser fired for 30s). All nets used were evaluated for functionality and strength (compared to 10 new nets). Student's T test was used to compare the studied parameters; significance was set at p < 0.05. Laser settings I and II caused less damage to the net overall; the mesh and wire frame had worst injuries with setting IV; setting III had an intermediate outcome; 42% of nets were rendered unusable and excluded from strength analysis. There was no difference in mean strength between used functional nets and non-used devices (8.05 vs. 7.45 lbs, respectively; p = 0.14). Setting IV was the most efficient for lithotripsy (1.9 ± 0.6 mg/s; p < 0.001) with or without net stabilization; setting III was superior to I and II only if a net was not used. Laser lithotripsy is not optimized by stone entrapment with a net retrieval device which may be damaged by high energy laser settings.

  5. [Detection of organic compounds on Mars].

    PubMed

    Kobayashi, K

    1997-03-01

    McKay et al. detected polycyclic aromatic hydrocarbons (PAHs) in Martian meteorite ALH 84001 by two-step laser mass spectrometry. From the presence of PAHs, together with other results, they concluded that there were past life of Mars. On the other hands, no organisms nor organic compounds were detected in Martian regolith in Viking experiments in 1976. In order to obtain solid evidence for organisms or bioorganic compounds compounds on Mars, further analyses of Martian samples are required. There may be four classes of organic compounds on Mars, which are (i) organic compounds abiotically formed from primitive Mars atmosphere, (ii) Organic compounds delivered out of Mars, (iii) Organic compounds biotically formed by Mars organisms, and (iv) Organic compounds abiotically formed from the present Mars atmosphere. Possible organic compounds on Mars and analytical methods for them are discussed.

  6. Safety of a picosecond laser with diffractive lens array (DLA) in the treatment of Fitzpatrick skin types IV to VI: A retrospective review.

    PubMed

    Haimovic, Adele; Brauer, Jeremy A; Cindy Bae, Yoon-Soo; Geronemus, Roy G

    2016-05-01

    Laser therapy in patients with skin of color is associated with an increased rate of complications. The 755-nm picosecond laser with the diffractive lens array (DLA) has been used for the treatment of scars, striae, and rejuvenation. By delivering high energy to focused areas, the DLA minimizes complications. This study explores the adverse events associated with treatment with the 755-nm picosecond laser with DLA in individuals with Fitzpatrick skin type IV to VI. A retrospective chart review of patients treated with the 755-nm picosecond laser with DLA with a standardized spot size of 6 mm, fluence of 0.71 J/cm(2), and pulse width of 750 to 850 picoseconds was performed. Standard clinical photographs were obtained before treatment and at follow-up. Treatment sites were assessed for dyspigmentation, erythema, edema, and herpetic lesions. A total of 56 patients with Fitzpatrick skin type IV to VI, atrophic and hypertrophic scars, and pigmented lesions or striae were included. Ten patients (17.9%) were lost to follow-up. Transient adverse events, most commonly erythema and hyperpigmentation, were reported after therapy; these resolved in all cases. Retrospective design is a limitation. The 755-nm picosecond laser with the DLA device may be a safe therapeutic alternative for unwanted scars, pigmented lesions, and striae in patients with skin of color. Copyright © 2015 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  7. 49 CFR 572.155 - Test conditions and instrumentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation potentiometer response (if used)—CFC 60. (3) Thorax: (i) Spine and pendulum accelerations—Class 180; (ii) Shoulder forces—Class 600; (4...

  8. 49 CFR 572.155 - Test conditions and instrumentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation potentiometer response (if used)—CFC 60. (3) Thorax: (i) Spine and pendulum accelerations—Class 180; (ii) Shoulder forces—Class 600; (4...

  9. 49 CFR 572.155 - Test conditions and instrumentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation potentiometer response (if used)—CFC 60. (3) Thorax: (i) Spine and pendulum accelerations—Class 180; (ii) Shoulder forces—Class 600; (4...

  10. 49 CFR 572.155 - Test conditions and instrumentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation potentiometer response (if used)—CFC 60. (3) Thorax: (i) Spine and pendulum accelerations—Class 180; (ii) Shoulder forces—Class 600; (4...

  11. 49 CFR 572.155 - Test conditions and instrumentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation potentiometer response (if used)—CFC 60. (3) Thorax: (i) Spine and pendulum accelerations—Class 180; (ii) Shoulder forces—Class 600; (4...

  12. Classification and Short-Term Course of DSM-IV Cannabis, Hallucinogen, Cocaine, and Opioid Disorders in Treated Adolescents

    ERIC Educational Resources Information Center

    Chung, Tammy; Martin, Christoper S.

    2005-01-01

    This study examined the latent class structure of Diagnostic and Statistical Manual of Mental Disorders (text rev.; DSM-IV; American Psychiatric Association, 2000) symptoms used to diagnose cannabis, hallucinogen, cocaine, and opiate disorders among 501 adolescents recruited from addictions treatment. Latent class results were compared with the…

  13. 40 CFR 147.2800 - State-administered program-Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false State-administered program-Class I, II, III, IV, and V wells. 147.2800 Section 147.2800 Protection of Environment ENVIRONMENTAL PROTECTION... Federal Register effective July 31, 1985. (1) CNMI Environmental Protection Act, 2 CMC sections 3101, et...

  14. 40 CFR 147.2800 - State-administered program-Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false State-administered program-Class I, II, III, IV, and V wells. 147.2800 Section 147.2800 Protection of Environment ENVIRONMENTAL PROTECTION... Federal Register effective July 31, 1985. (1) CNMI Environmental Protection Act, 2 CMC sections 3101, et...

  15. 40 CFR 147.2800 - State-administered program-Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false State-administered program-Class I, II, III, IV, and V wells. 147.2800 Section 147.2800 Protection of Environment ENVIRONMENTAL PROTECTION... Federal Register effective July 31, 1985. (1) CNMI Environmental Protection Act, 2 CMC sections 3101, et...

  16. 40 CFR 147.2800 - State-administered program-Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false State-administered program-Class I, II, III, IV, and V wells. 147.2800 Section 147.2800 Protection of Environment ENVIRONMENTAL PROTECTION... Federal Register effective July 31, 1985. (1) CNMI Environmental Protection Act, 2 CMC sections 3101, et...

  17. 40 CFR 147.2800 - State-administered program-Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 24 2013-07-01 2013-07-01 false State-administered program-Class I, II, III, IV, and V wells. 147.2800 Section 147.2800 Protection of Environment ENVIRONMENTAL PROTECTION... Federal Register effective July 31, 1985. (1) CNMI Environmental Protection Act, 2 CMC sections 3101, et...

  18. Abundance of truncated and full-length ChitA and ChitB chitinases in healthy and diseased maize tissues

    USDA-ARS?s Scientific Manuscript database

    Chitinase modifying proteins, cmps, are secreted fungal proteases that combat plant defenses by truncating plant class IV chitinases. We initially discovered that ChitA and ChitB, two plant class IV chitinases that are abundant in developing and mature kernels of corn, are truncated by cmps during e...

  19. Cloning and identification of Fv-cmp, a protease from Fusarium verticillioides that truncates Zea mays and Arabidopsis thaliana class IV chitinases

    USDA-ARS?s Scientific Manuscript database

    Chitinase modifying proteins (cmps) are proteases, secreted by fungal pathogens, that were originally identified as proteins that truncate class IV chitinases of maize during ear rot. Cmps from Bipolaris zeicola and Stenocarpella maydis have been characterized, but the identities of the proteases h...

  20. 40 CFR 147.2550 - State-administered program-Class I, III, IV and V wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Rules and Regulations, Wyoming Department of Environmental Quality, Chapter XXI: In Situ Mining... program for Class I, III, IV and V wells in the State of Wyoming, except those on Indian lands is the... section 1422 of the SDWA. Notice of this approval was published in the Federal Register on July 15, 1983...

  1. 40 CFR 147.2550 - State-administered program-Class I, III, IV and V wells.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Rules and Regulations, Wyoming Department of Environmental Quality, Chapter XXI: In Situ Mining... program for Class I, III, IV and V wells in the State of Wyoming, except those on Indian lands is the... section 1422 of the SDWA. Notice of this approval was published in the Federal Register on July 15, 1983...

  2. [Microinvasive dental treatment in pre-school children].

    PubMed

    Korolenkova, M V

    The aim of the study was to assess the efficiency of atraumatic restorative treatment (ART) with cavity preparation by means of dental endo motor. ART method was applied in 94 children (50 females and 44 males, 301 teeth treated) aged 21-96 months. Wireless dental endo motor (Endo Mate TC2, NSK, Japan) was used for cavity preparation. The cavities (102 (33.9%) class I, 156 (51.8%) class V, 20 (6.6%) class II, 18 (6%) class III and 5 (1.7%) class IV) were then filled with glass-ionomer cement (Fuji IX, GC, Japan). Success rate was assessed 3, 6, 12 and 18 months after treatment. Overall ART procedure success rate (good marginal fit, no occlusal wearing or restoration fractures) at 18-month follow up was 88.7% (267 fillings out of 301) with the highest survival in class I (96.1%) and class V (96.2%) restoration and poorest in class II (50%), class III (44.4%) and class IV (20%) restorations. Cavity preparation with wireless dental endo motor was well tolerated even by infants (12 children were younger than 24 months), as it is noiseless and significantly faster than conventional manual preparation. ART method with the use of dental endo motor showed good success rate and proved to be highly efficient in small and apprehensive children. The method, however, should be avoided in class III and IV cavities as the success rate is poor mostly because of restoration fractures.

  3. A Longitudinal Study on the Effects of Laser Refractive Eye Surgery in Military Aircrew

    DTIC Science & Technology

    2005-02-01

    Photorefractive Keratectomy ( PRK ) and Laser in situ keratomileusis ( LASIK ) have been approved for all classes of licenses providing the clinical...photoréfractive ( PRK ) et la kératomileusie in-situ au laser ( LASIK ) ont été approuvées pour toutes les classes de licences à condition que les résultats...had approved PRK and LASIK for all classes of licenses in Civilian Aviation, provided that the clinical outcome was satisfactory and that minimum

  4. The Marine Corps Needs a Targeting, Sensors, and Surveillance Systems Operational Integration and Support Team

    DTIC Science & Technology

    2010-03-02

    triggerman is probably still close ; lately all IEDs in the area have been initiated via command-wire. The squad leader sets a cordon, ensures an IED 9...Operational Surveillance System (G-BOSS) with a Class IIIb laser pointer. This class of laser requires users to receive a laser safety class...2) The Keyhole kit of surveillance equipment. Designed to provide “snipers with an increased capability to visually detect the enemy emplacing IEDs

  5. 76 FR 20992 - Guidance for Industry and Food and Drug Administration Staff; Class II Special Controls Guidance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-14

    ...: Low Level Laser System for Aesthetic Use; Availability AGENCY: Food and Drug Administration, HHS... guidance entitled ``Class II Special Controls Guidance Document: Low Level Laser System for Aesthetic Use.'' This guidance document describes a means by which low level laser systems for aesthetic use may comply...

  6. A simple approach to industrial laser safety.

    PubMed

    Lewandowski, Michael A; Hinz, Michael W

    2005-02-01

    Industrial applications of lasers include marking, welding, cutting, and other material processing. Lasers used in these ways have significant power output but are generally designed to limit operator exposure to direct or scattered laser radiation to harmless levels in order to meet the Federal Laser Product Performance Standard (21CFR1040) for Class 1 laser products. Interesting challenges occur when companies integrate high power lasers into manufacturing or process control equipment. A significant part of the integration process is developing engineering and administrative controls to produce an acceptable level of laser safety while balancing production, maintenance, and service requirements. 3M Company uses a large number of high power lasers in numerous manufacturing processes. Whether the laser is purchased as a Class 1 laser product or whether it is purchased as a Class 4 laser and then integrated into a manufacturing application, 3M Company has developed an industrial laser safety program that maintains a high degree of laser safety while facilitating the rapid and economical integration of laser technology into the manufacturing workplace. This laser safety program is based on the requirements and recommendations contained in the American National Standard for Safe Use of Lasers, ANSI Z136.1. The fundamental components of the 3M program include hazard evaluation, engineering, administrative, and procedural controls, protective equipment, signs and labels, training, and re-evaluation upon change. This program is implemented in manufacturing facilities and has resulted in an excellent history of laser safety and an effective and efficient use of laser safety resources.

  7. How Y-Family DNA polymerase IV is more accurate than Dpo4 at dCTP insertion opposite an N2-dG adduct of benzo[a]pyrene.

    PubMed

    Sholder, Gabriel; Creech, Amanda; Loechler, Edward L

    2015-11-01

    To bypass DNA damage, cells have Y-Family DNA polymerases (DNAPs). One Y-Family-class includes DNAP κ and DNAP IV, which accurately insert dCTP opposite N(2)-dG adducts, including from the carcinogen benzo[a]pyrene (BP). Another class includes DNAP η and DNAP V, which insert accurately opposite UV-damage, but inaccurately opposite BP-N(2)-dG. To investigate structural differences between Y-Family-classes, regions are swapped between DNAP IV (a κ/IV-class-member) and Dpo4 (a η/V-class-member); the kinetic consequences are evaluated via primer-extension studies with a BP-N(2)-dG-containing template. Four key structural elements are revealed. (1) Y-Family DNAPs have discreet non-covalent contacts between their little finger-domain (LF-Domain) and their catalytic core-domain (CC-Domain), which we call "non-covalent bridges" (NCBs). Arg37 and Arg38 in DNAP IV's CC-Domain near the active site form a non-covalent bridge (AS-NCB) by interacting with Glu251 and Asp252, respectively, in DNAP IV's LF-Domain. Without these interactions dATP/dGTP/dTTP misinsertions increase. DNAP IV's AS-NCB suppresses misinsertions better than Dpo4's equivalent AS-NCB. (2) DNAP IV also suppresses dATP/dGTP/dTTP misinsertions via a second non-covalent bridge, which is ∼8Å from the active site (Distal-NCB). Dpo4 has no Distal-NCB, rendering it inferior at dATP/dGTP/dTTP suppression. (3) dCTP insertion is facilitated by the larger minor groove opening near the active site in DNAP IV versus Dpo4, which is sensible given that Watson/Crick-like [dCTP:BP-N(2)-dG] pairing requires the BP-moiety to be in the minor groove. (4) Compared to Dpo4, DNAP IV has a smaller major groove opening, which suppresses dGTP misinsertion, implying BP-N(2)-dG bulk in the major groove during Hoogsteen syn-adduct-dG:dGTP pairing. In summary, DNAP IV has a large minor groove opening to enhance dCTP insertion, a plugged major groove opening to suppress dGTP misinsertion, and two non-covalent bridges (near and distal to the active site) to suppress dATP/dGTP/dTTP misinsertions; collectively these four structural features enhance DNAP IV's dNTP insertion fidelity opposite a BP-N(2)-dG adduct compared to Dpo4. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Excimer laser coronary angioplasty: relative risk analysis of clinical results

    NASA Astrophysics Data System (ADS)

    Bittl, John A.

    1992-08-01

    Reports of successful use of excimer laser coronary angioplasty for complex coronary artery disease abound, yet firm indications for its use have not been defined. We attempted to treat 858 coronary stenoses in 764 consecutive patients (mean age 61 years; range 32 - 91 years; 75% men; 76% with Class III or IV angina) with excimer laser angioplasty at 308 nm. Successful treatment was achieved in 86% of patients, as indicated by 20 mm), total occlusions and calcified lesions were treated as successfully as all other lesion types. Successful treatment with excimer laser coronary angioplasty was also achieved in almost all patients (15/16) who had a prior unsuccessful attempt at balloon angioplasty in the lesion was crossed with a guidewire yet resists either balloon catheter passage or full dilatation. Follow-up angiography was obtained in 70% of eligible patients. Angiographic restenosis, defined by > 50% stenosis, was seen in 60% of patients. Relative risk analysis showed an increased risk of restenosis when adjunctive balloon angioplasty was not used (OR equals 1.68; 95% CI equals 1.02, 2.28; P equals 0.039). Other variables known to affect the outcome of balloon angioplasty, such as lesion length or stenosis in degenerated saphenous vein bypass graft, did not influence the restenosis rates. This analysis defines the profile of risk for excimer laser angioplasty and now provides a sound basis for future, rigorous comparison of excimer laser and balloon angioplasty to balloon angioplasty for a group of lesions that appear to have acceptable success rates with excimer laser coronary angioplasty, which we have denoted the `alpha class' -- saphenous vein lesions, long lesions, ostial stenoses, lesions in calcified vessels, total occlusions, and balloon dilatation failures. Although adjunctive balloon angioplasty may be beneficial, restenosis remains a significant limitation of the procedure and will restrict the usefulness of excimer laser coronary angioplasty for may other types of lesions.

  9. Revision of the International Society of Nephrology/Renal Pathology Society classification for lupus nephritis: clarification of definitions, and modified National Institutes of Health activity and chronicity indices.

    PubMed

    Bajema, Ingeborg M; Wilhelmus, Suzanne; Alpers, Charles E; Bruijn, Jan A; Colvin, Robert B; Cook, H Terence; D'Agati, Vivette D; Ferrario, Franco; Haas, Mark; Jennette, J Charles; Joh, Kensuke; Nast, Cynthia C; Noël, Laure-Hélène; Rijnink, Emilie C; Roberts, Ian S D; Seshan, Surya V; Sethi, Sanjeev; Fogo, Agnes B

    2018-04-01

    We present a consensus report pertaining to the improved clarity of definitions and classification of glomerular lesions in lupus nephritis that derived from a meeting of 18 members of an international nephropathology working group in Leiden, Netherlands, in 2016. Here we report detailed recommendations on issues for which we can propose adjustments based on existing evidence and current consensus opinion (phase 1). New definitions are provided for mesangial hypercellularity and for cellular, fibrocellular, and fibrous crescents. The term "endocapillary proliferation" is eliminated and the definition of endocapillary hypercellularity considered in some detail. We also eliminate the class IV-S and IV-G subdivisions of class IV lupus nephritis. The active and chronic designations for class III/IV lesions are replaced by a proposal for activity and chronicity indices that should be applied to all classes. In the activity index, we include fibrinoid necrosis as a specific descriptor. We also make recommendations on issues for which there are limited data at present and that can best be addressed in future studies (phase 2). We propose to proceed to these investigations, with clinicopathologic studies and tests of interobserver reproducibility to evaluate the applications of the proposed definitions and to classify lupus nephritis lesions. Copyright © 2018 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  10. Examining the Stability of "DSM-IV" and Empirically Derived Eating Disorder Classification: Implications for "DSM-5"

    ERIC Educational Resources Information Center

    Peterson, Carol B.; Crow, Scott J.; Swanson, Sonja A.; Crosby, Ross D.; Wonderlich, Stephen A.; Mitchell, James E.; Agras, W. Stewart; Halmi, Katherine A.

    2011-01-01

    Objective: The purpose of this investigation was to derive an empirical classification of eating disorder symptoms in a heterogeneous eating disorder sample using latent class analysis (LCA) and to examine the longitudinal stability of these latent classes (LCs) and the stability of DSM-IV eating disorder (ED) diagnoses. Method: A total of 429…

  11. Mathematical Relationships between Neuron Morphology and Neurite Growth Dynamics in Drosophila melanogaster Larva Class IV Sensory Neurons

    NASA Astrophysics Data System (ADS)

    Ganguly, Sujoy; Liang, Xin; Grace, Michael; Lee, Daniel; Howard, Jonathon

    The morphology of neurons is diverse and reflects the diversity of neuronal functions, yet the principles that govern neuronal morphogenesis are unclear. In an effort to better understand neuronal morphogenesis we will be focusing on the development of the dendrites of class IV sensory neuron in Drosophila melanogaster. In particular we attempt to determine how the the total length, and the number of branches of dendrites are mathematically related to the dynamics of neurite growth and branching. By imaging class IV neurons during early embryogenesis we are able to measure the change in neurite length l (t) as a function of time v (t) = dl / dt . We found that the distribution of v (t) is well characterized by a hyperbolic secant distribution, and that the addition of new branches per unit time is well described by a Poisson process. Combining these measurements with the assumption that branching occurs with equal probability anywhere along the dendrite we were able to construct a mathematical model that provides reasonable agreement with the observed number of branches, and total length of the dendrites of the class IV sensory neuron.

  12. The role of single immediate loading implant in long Class IV Kennedy mandibular partial denture.

    PubMed

    Mohamed, Gehan F; El Sawy, Amal A

    2012-10-01

    The treatment of long-span Kennedy class IV considers a prosthodontic challenge. This study evaluated the integrity of principle abutments in long Kennedy class IV clinically and radiographically, when rehabilitated with conventional metallic partial denture as a control group and mandibular partial overdentures supported with single immediately loaded implant in symphyseal as a study group. Twelve male patients were divided randomly allotted into two equal groups. First group patients received removable metallic partial denture, whereas in the second group, patients received partial overdentures supported with single immediately loaded implant in symphyseal region. The partial dentures design in both groups was the same. Long-cone paralleling technique and transmission densitometer were used at the time of denture insertion, 3, 6, and 12 months. Gingival index, bone loss, and optical density were measured for principle abutments during the follow-up. A significant reduction in bone loss and density were detected in group II comparing with group I. Gingival index had no significant change (p-value < 0.05). A single symphyseal implant in long span class IV Kennedy can play a pivotal role to improve the integrity of the principle abutments and alveolar bone support. © 2010 Wiley Periodicals, Inc.

  13. Heat generated by Er:YAG laser in the pulp chamber of teeth submitted to removal of dental tissue and composite resin

    NASA Astrophysics Data System (ADS)

    Zanin, Fatima; Brugnera, Aldo, Jr.; Pecora, Jesus D.; Pinheiro, Antonio; Spano, Julio; Barbin, Eduardo; Marchesan, Melissa A.

    2004-05-01

    The knowledge about and control of thermal energy produced by Er:YAG laser after irradiating hard dental tissues and compound resin is important because the pulp, like all vital biological tissue, has a certain capacity for supporting stimulus. The objective of this study was to analyze the thermal variation generated by Er:YAG laser (λ=2.94μm) during the preparation of a Class I cavity in the dental structure and in the removal of microhybrid Z100 (3M) compound resin. An evaluation was made of 30 maxillary human pre-molar teeth from the bank of the Endodontic Laboratory Center of Ribeirao Preto Dental School, Brasil. The sample was divided into 6 groups of 5 teeth each: Group 1, preparation of Class I cavity with Er:YAG laser (350mJ, 3Hz, 343 impulses, 120J, 113 seconds); Group 2, preparation of Class I cavity with Er:YAG laser (350mJ, 4Hz, 343 impulses, 120J, 81 seconds); Group 3, preparation of Class I cavity with Er:YAG laser (350mJ, 6Hz, 343 impulses, 120J, 58 seconds); Group 4, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 3Hz, 258 impulses, 90J, 85 seconds); Group 5, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 4Hz, 258 impulses, 90J, 67 seconds); Group 6, removal of compound resin from Class I preparation with Er:YAG laser (350mJ, 6Hz, 258 impulses, 42 seconds). The laser used was KaVo Key 2 (Biberach, Germany), λ=2,94μm, P=3 Watts, pulse duration of 250μs, with air-water cooling. The increase in temperature during dental preparation and the removal of the compound resin was evaluated by means of a Tektronix DMM916 Thermocouple (Consitec, Brasil). The results showed that the application of laser for the removal of the hard dental tissues and for the removal of compound resins with the pulse frequencies 3, 4 and 6 Hz did not generate heating greater than 3.1°C and remained within the histopathological limits permitted for pulp tissue (5.5°C) and there was a significant statistical difference between the heat generated by the application of laser in the removal of the hard dental tissues and in the removal of compound resins (p<0.01). The average increase in temperature of the compound resin component was greater than the tooth.

  14. Latent class instrumental variables: A clinical and biostatistical perspective

    PubMed Central

    Baker, Stuart G.; Kramer, Barnett S.; Lindeman, Karen S.

    2015-01-01

    In some two-arm randomized trials, some participants receive the treatment assigned to the other arm as a result of technical problems, refusal of a treatment invitation, or a choice of treatment in an encouragement design. In some before-and-after studies, the availability of a new treatment changes from one time period to this next. Under assumptions that are often reasonable, the latent class instrumental variable (IV) method estimates the effect of treatment received in the aforementioned scenarios involving all-or-none compliance and all-or-none availability. Key aspects are four initial latent classes (sometimes called principal strata) based on treatment received if in each randomization group or time period, the exclusion restriction assumption (in which randomization group or time period is an instrumental variable), the monotonicity assumption (which drops an implausible latent class from the analysis), and the estimated effect of receiving treatment in one latent class (sometimes called efficacy, the local average treatment effect, or the complier average causal effect). Since its independent formulations in the biostatistics and econometrics literatures, the latent class IV method (which has no well-established name) has gained increasing popularity. We review the latent class IV method from a clinical and biostatistical perspective, focusing on underlying assumptions, methodological extensions, and applications in our fields of obstetrics and cancer research. PMID:26239275

  15. Super-Radiant Free Electron Laser Measurement and Detection

    DTIC Science & Technology

    2013-09-01

    collection of information is estimated to average 1 hour per response, including the time for reviewing instruction, searching existing data sources... relativistic electron bunches and a periodic magnetic field to generate coherent radiation. These types of lasers are of interest to the Navy because...Physics iv THIS PAGE INTENTIONALLY LEFT BLANK v ABSTRACT A free electron laser (FEL) is a type of laser that use relativistic electron bunches

  16. Influence of class IV laser therapy on the outcomes of tibial plateau leveling osteotomy in dogs.

    PubMed

    Renwick, S Michelle; Renwick, Alasdair I; Brodbelt, David C; Ferguson, John; Abreu, Humberto

    2018-04-26

    To determine the effects of low-level laser therapy (LLLT) on clinical outcomes in dogs with cranial cruciate ligament disease treated with tibial plateau leveling osteotomy (TPLO). Randomized, placebo-controlled clinical trial. Owners and surgeons (care providers and assessors) were masked. Ninety-five dogs were admitted for TPLO and assigned to 1 of 2 groups, laser group (LG; n = 51) or placebo group (PG; n = 44). Three treatments (laser or placebo) were administered within a 4-day perioperative period. A fourth treatment was recommended and was accepted in 28.4% of cases (LG, n = 14; PG, n = 13). Dogs in the LG group received laser at wavelengths 660 nm red (100 mW) and at 800, 905 and 970 nm infrared (maximum 15 W continuous wave, 20 W peak pulsed wave), administered simultaneously. Dogs in the PG group received placebo laser (660 nm, 4 mW). Other treatments were identical. Outcomes were measured by difference in clinical metrology instruments (Liverpool Osteoarthritis in Dogs and adjusted Canine Orthopedic Index [COI]), osteotomy healing on a radiographic scale, time to cessation of nonsteroidal anti-inflammatory drug administration, and wound healing by owner questionnaire. The only difference detected between groups consisted of a greater improvement in the gait section of the adjusted COI (ACOI) in the LG group (median [interquartile range; IQR] = 6 [4-7.5]) compared with the PG group (median [IQR] = 4 [2-6]; P < .05). The laser protocol used in this study was associated with a greater improvement in ACOI gait in dogs treated with TPLO but did not improve any other clinical metrology instrument scores or bone healing. This study provides some evidence that LLLT may improve the gait of dogs recovering from a TPLO, as assessed by owners. © 2018 The American College of Veterinary Surgeons.

  17. Primary photochemical processes for Pt(iv) diazido complexes prospective in photodynamic therapy of tumors.

    PubMed

    Shushakov, Anton A; Pozdnyakov, Ivan P; Grivin, Vjacheslav P; Plyusnin, Victor F; Vasilchenko, Danila B; Zadesenets, Andrei V; Melnikov, Alexei A; Chekalin, Sergey V; Glebov, Evgeni M

    2017-07-25

    Diazide diamino complexes of Pt(iv) are considered as prospective prodrugs in oxygen-free photodynamic therapy (PDT). Primary photophysical and photochemical processes for cis,trans,cis-[Pt(N 3 ) 2 (OH) 2 (NH 3 ) 2 ] and trans,trans,trans-[Pt(N 3 ) 2 (OH) 2 (NH 3 ) 2 ] complexes were studied by means of stationary photolysis, nanosecond laser flash photolysis and ultrafast kinetic spectroscopy. The process of photolysis is multistage. The first stage is the photosubstitution of an azide ligand to a water molecule. This process was shown to be a chain reaction involving redox stages. Pt(iv) and Pt(iii) intermediates responsible for the chain propagation were recorded using ultrafast kinetic spectroscopy and nanosecond laser flash photolysis. The mechanism of photosubstitution is proposed.

  18. Fundamental Study of Nuclear Pumped Laser Plasmas.

    DTIC Science & Technology

    1980-12-23

    PUMPED DYE LASER PMT PUMPING/ GAS HAND- LING SYSTEM ANODE SIGNAL TO SCREEN ROOM FIGURE 13 EXPERIMENTAL APPARATUS FROM ANODE OF PMT SCREEN ROOM...and G.A. Zdasiuk, " Laser Induced Collisional and Radiative Energy Transfer’, Proceedings of Laser Spectroscopy IV, June 1979. W. R. Green, M.D. Wright...AD-A130 988 FUNDAMENTAL STUDY 0F NUCLEAR PUMPED LASER PLASMAS(U) 1/ MIAMI UNIV OXFORD UHDi EPT OF PHYSIS Cs W DOWNES ET AL 23 DEC AS OASGAS 7A C OSAN

  19. High energy electron acceleration with PW-class laser system

    NASA Astrophysics Data System (ADS)

    Nakanii, N.; Kondo, K.; Mori, Y.; Miura, E.; Yabuuchi, T.; Tsuji, K.; Suzuki, S.; Asaka, T.; Yanagida, K.; Hanaki, H.; Kobayashi, T.; Makino, K.; Yamane, T.; Miyamoto, S.; Horikawa, K.; Kimura, K.; Takeda, K.; Fukumochi, S.; Kashihara, M.; Tanimoto, T.; Nakamura, H.; Ishikura, T.; Tampo, M.; Kodama, R.; Kitagawa, Y.; Mima, K.; Tanaka, K. A.

    2008-06-01

    We performed electron acceleration experiment with PW-class laser and a plasma tube, which was created by imploding a hollow polystyrene cylinder. In this experiment, electron energies in excess of 600 MeV have been observed. Moreover, the spectra of a comparatively high-density plasma ˜1019 cm-3 had a bump around 10 MeV. Additionally, we performed the absolute sensitivity calibration of imaging plate for 1 GeV electrons from the injector Linac of Spring-8 in order to evaluate absolute number of GeV-class electrons in the laser acceleration experiment.

  20. Retinal damage induced by mirror-reflected light from a laser pointer.

    PubMed

    Thanos, Solon; Böhm, Michael R R; Meyer zu Hörste, Melissa; Schmidt, Peter-Fritz

    2015-10-05

    The safety of laser pointers is a major public health issue since class I and II laser pointers are available worldwide and used as toys by children despite several reports cautioning such use. Here we present the first case of retinal injury caused by the laser beam of a toy laser pointer operated by a school boy and directed via the rear-view mirror of a bus into the eye of the driver. This case emphasises the great importance of cautious and appropriate use of low-energy laser pointers. Laser pointers of any class should not be made available to children because they are unlikely to understand the risks of such lasers when using them in play. 2015 BMJ Publishing Group Ltd.

  1. 76 FR 20840 - Medical Devices; General and Plastic Surgery Devices; Classification of the Low Level Laser...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-14

    ... into class II (special controls). The special control(s) that will apply to the device is entitled ``Class II Special Controls Guidance Document: Low Level Laser System for Aesthetic Use.'' The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety...

  2. Ultra-high brightness wavelength-stabilized kW-class fiber coupled diode laser

    NASA Astrophysics Data System (ADS)

    Huang, Robin K.; Chann, Bien; Glenn, John D.

    2011-03-01

    TeraDiode has produced a fiber-coupled direct diode laser with a power level of 1,040 W from a 200 μm core diameter, 0.18 numerical aperture (NA) output fiber at a single center wavelength. This was achieved with a novel beam combining and shaping technique using COTS diode lasers. The fiber-coupled output corresponds to a Beam Parameter Product (BPP) of 18 mm-mrad and is the lowest BPP kW-class direct diode laser yet reported. The laser has been used to demonstrate laser cutting and welding of steel sheet metal up to 6.65 mm thick. Further advances of these ultra-bright lasers are also projected.

  3. Intravenous Vancomycin Associated With the Development of Nephrotoxicity in Patients With Class III Obesity.

    PubMed

    Choi, Yookyung Christy; Saw, Stephen; Soliman, Daniel; Bingham, Angela L; Pontiggia, Laura; Hunter, Krystal; Chuang, Linda; Siemianowski, Laura A; Ereshefsky, Benjamin; Hollands, James M

    2017-11-01

    A consensus statement recommends initial intravenous (IV) vancomycin dosing of 15-20 mg/kg every 8- 24 hours, with an optional 25- to 30-mg/kg loading dose. Although some studies have shown an association between weight and the development of vancomycin-associated nephrotoxicity, results have been inconsistent. To evaluate the correlation between incidence of nephrotoxicity associated with weight-based IV vancomycin dosing strategies in nonobese and obese patients. This retrospective cohort study evaluated hospitalized adult patients admitted who received IV vancomycin. Patients were stratified into nonobese (body mass index [BMI] <25 kg/m 2 ), obesity class I and II (BMI 30-39.9kg/m 2 ), and obesity class III (BMI≥40 kg/m 2 ) groups; patients who were overweight but not obese were excluded. Incidence of nephrotoxicity and serum vancomycin trough concentrations were evaluated. Of a total of 62 documented cases of nephrotoxicity (15.1%), 13 (8.7%), 23 (14.3%), and 26 (26.3%) cases were observed in nonobese, obesity class I and II, and obesity class III groups, respectively ( P=0.002). Longer durations of therapy ( P<0.0001), higher initial maintenance doses in both total milligrams/day ( P=0.0137) and milligrams/kilogram ( P=0.0307), and any trough level >20 mg/L ( P<0.0001) were identified as predictors of development of nephrotoxicity. Concomitant administration of piperacillin/tazobactam, diuretics, and IV contrast were associated with development of nephrotoxicity ( P<0.005, all). Patients with class III obesity were 3-times as likely to develop nephrotoxicity when compared with nonobese patients (odds ratio [OR]=2.99; CI=1.12-7.94) and obesity class I and II patients (OR=3.14; CI=1.27-7.75). Obesity and other factors are associated with a higher risk of vancomycin-associated nephrotoxicity.

  4. Digitized Speech Characteristics in Patients with Maxillectomy Defects.

    PubMed

    Elbashti, Mahmoud E; Sumita, Yuka I; Hattori, Mariko; Aswehlee, Amel M; Taniguchi, Hisashi

    2017-12-06

    Accurate evaluation of speech characteristics through formant frequency measurement is important for proper speech rehabilitation in patients after maxillectomy. This study aimed to evaluate the utility of digital acoustic analysis and vowel pentagon space for the prediction of speech ability after maxillectomy, by comparing the acoustic characteristics of vowel articulation in three classes of maxillectomy defects. Aramany's classifications I, II, and IV were used to group 27 male patients after maxillectomy. Digital acoustic analysis of five Japanese vowels-/a/, /e/, /i/, /o/, and /u/-was performed using a speech analysis system. First formant (F1) and second formant (F2) frequencies were calculated using an autocorrelation method. Data were plotted on an F1-F2 plane for each patient, and the F1 and F2 ranges were calculated. The vowel pentagon spaces were also determined. One-way ANOVA was applied to compare all results between the three groups. Class II maxillectomy patients had a significantly higher F2 range than did Class I and Class IV patients (p = 0.002). In contrast, there was no significant difference in the F1 range between the three classes. The vowel pentagon spaces were significantly larger in class II maxillectomy patients than in Class I and Class IV patients (p = 0.014). The results of this study indicate that the acoustic characteristics of maxillectomy patients are affected by the defect area. This finding may provide information for obturator design based on vowel articulation and defect class. © 2017 by the American College of Prosthodontists.

  5. Drug formulations intended for the global market should be tested for stability under tropical climatic conditions.

    PubMed

    Risha, P G; Vervaet, C; Vergote, G; Bortel, L Van; Remon, J P

    2003-06-01

    The quality of drugs imported into developing countries having a tropical climate may be adversely affected if their formulations have not been optimized for stability under these conditions. The present study investigated the influence of tropical climate conditions (class IV: 40 degrees C, 75% relative humidity) on the drug content, in vitro dissolution and oral bioavailability of different formulations of two essential drugs marketed in Tanzania: diclofenac sodium and ciprofloxacin tablets. Before and after 3 and 6 months storage under class IV conditions the drug content and in vitro dissolution were evaluated using United States Pharmacopoeia (USP) 24 methods. Following a randomized four-period cross-over study, the pharmacokinetic parameters of drug formulations stored for 3 months under class IV conditions were compared with those stored at ambient conditions. Drug content and drug release from all tested ciprofloxacin formulations were within USP-24 requirements and remained stable during storage at simulated tropical conditions. Oral bioavailability was also not influenced by tropical conditions. The dissolution rate of two diclofenac formulations (Diclo 50 manufactured by Camden and Dicloflame 50 manufactured by Intas) reduced significantly during storage under class IV conditions. After oral administration Camden tablets stored for 3 months under class IV conditions showed a reduction in C(max) (90% CI of C(max) ratio: 0.59 - 0.76). This reduction was smaller than expected based on the in vitro tests. Some drug formulations imported into Tanzania are not optimized for stability in a tropical climate. Manufacturers and regulatory authorities should pay more attention to the WHO recommendations for testing the stability of drugs under tropical climate conditions. Efforts should be made to improve the in vitro tests to better predict the bioavailability.

  6. Time-resolved laser spectroscopy of multiply ionized atoms: natural radiative lifetimes in Ce IV.

    PubMed

    Zhang, Z G; Svanberg, S; Quinet, P; Palmeri, P; Biémont, E

    2001-12-31

    Radiative lifetimes have been measured for two excited levels of Ce IV using the time-resolved laser-induced fluorescence technique. Ce3+ ions were produced in a laser-induced plasma. In the measurements, a suitable magnetic field was applied to reduce the recombination between electrons and the ions and thus the background light from the recombination, and special care was exercised to avoid flight-out-of-view effects on the lifetime measurements for the high-velocity ions. The experimental lifetime results, tau = 30(2) ns for the level 49 737 cm(-1) and tau = 30(3) ns for the level 52 226 cm(-1), were compared with relativistic Hartree-Fock calculations (tau = 30.5 and 30.0 ns) indicating a particularly excellent agreement.

  7. Resurfacing of Facial Acne Scars With a New Variable-Pulsed Er:YAG Laser in Fitzpatrick Skin Types IV and V.

    PubMed

    Chathra, Namitha; Mysore, Venkataram

    2018-01-01

    The Er:YAG laser, considered to be less effective than CO 2 laser in its traditional form, in its new modulated version has variable pulse technology that is claimed to be superior to the earlier versions of the laser. The aim of the study was to check efficacy and safety of the new variable square pulse (VSP) Er:YAG laser in the management of acne scar in patients with Fitzpatrick skin types IV and V. This retrospective study consisted of 80 patients (Fitzpatrick skin types IV and V) with atrophic and hypertrophic facial acne scars. Records of the patients who had undergone four treatment sessions with VSP technology equipped with Er:YAG laser were extracted. Each patient had undergone a minimum of four sessions. Fractional mode at medium laser pulse (SP) and long pulse (LP) was employed for the depressed center of the scars to stimulate neocollagenogenesis. Short laser pulse (MSP) in nonfractionated mode was used for ablating the raised scar border and hypertrophic scars. Goodman and Baron global scarring grading system was used for qualitative and quantitative assessments. Patient's satisfaction to the treatment and observer's assessment of improvement (based on photographs) was graded as poor (<25% improvement), fair (25-50% improvement), good (51-75% improvement), and excellent (>75% improvement). At the end of the four sessions, the number of patients in grade IV postacne scarring reduced from 16 to 2 and that in grade III from 47 to 29. The mean score significantly dropped from 36.94 to 27.5. Subjective assessment revealed that 78 of 80 patients had noticed more than 25% improvement, with 50 of them showing more than 50% improvement at the end of four sessions. Eight patients perceived an excellent response and 42 reported a good response. This is notably higher than the observer's grading, which showed an excellent response in only 2 patients and a good response in 35. Adverse effects were limited to prolonged erythema (two patients), prolonged crusting (one patient), and postinflammatory hyperpigmentation (one patient). Ninety-seven percent of the subjects in our study perceived at least a fair improvement. We also saw a significant change in the objective score with a fall of the mean quantitative score from 36.94 to 27.15. This underscores the new variable-pulsed Er:YAG laser's effectiveness in the treatment of acne scars. It also has the added advantage of lesser adverse events and faster healing.

  8. Direct diode lasers with comparable beam quality to fiber, CO2, and solid state lasers

    NASA Astrophysics Data System (ADS)

    Huang, Robin K.; Chann, Bien; Burgess, James; Kaiman, Michael; Overman, Robert; Glenn, John D.; Tayebati, Parviz

    2012-03-01

    TeraDiode has produced kW-class ultra-high brightness fiber-coupled direct diode lasers. A fiber-coupled direct diode laser with a power level of 2,040 W from a 50 μm core diameter, 0.15 numerical aperture (NA) output fiber at a single center wavelength was demonstrated. This was achieved with a novel beam combining and shaping technique using COTS diode lasers. The fiber-coupled output corresponds to a Beam Parameter Product (BPP) of 3.75 mm-mrad and is the lowest BPP kW-class direct diode laser yet reported. This laser is suitable for industrial materials processing applications, including sheet metal cutting and welding. This 2-kW fiber-coupled direct diode laser has comparable brightness to that of industrial fiber lasers and CO2 lasers, and is over 10x brighter than state-of-the-art direct diode lasers.

  9. Interobserver agreement on histopathological lesions in class III or IV lupus nephritis.

    PubMed

    Wilhelmus, Suzanne; Cook, H Terence; Noël, Laure-Hélène; Ferrario, Franco; Wolterbeek, Ron; Bruijn, Jan A; Bajema, Ingeborg M

    2015-01-07

    To treat lupus nephritis effectively, proper identification of the histologic class is essential. Although the classification system for lupus nephritis is nearly 40 years old, remarkably few studies have investigated interobserver agreement. Interobserver agreement among nephropathologists was studied, particularly with respect to the recognition of class III/IV lupus nephritis lesions, and possible causes of disagreement were determined. A link to a survey containing pictures of 30 glomeruli was provided to all 360 members of the Renal Pathology Society; 34 responses were received from 12 countries (a response rate of 9.4%). The nephropathologist was asked whether glomerular lesions were present that would categorize the biopsy as class III/IV. If so, additional parameters were scored. To determine the interobserver agreement among the participants, κ or intraclass correlation values were calculated. The intraclass correlation or κ-value was also calculated for two separate levels of experience (specifically, nephropathologists who were new to the field or moderately experienced [less experienced] and nephropathologists who were highly experienced). Intraclass correlation for the presence of a class III/IV lesion was 0.39 (poor). The κ/intraclass correlation values for the additional parameters were as follows: active, chronic, or both: 0.36; segmental versus global: 0.39; endocapillary proliferation: 0.46; influx of inflammatory cells: 0.32; swelling of endothelial cells: 0.46; extracapillary proliferation: 0.57; type of crescent: 0.46; and wire loops: 0.35. The highly experienced nephropathologists had significantly less interobserver variability compared with the less experienced nephropathologists (P=0.004). There is generally poor agreement in terms of recognizing class III/IV lesions. Because experience clearly increases interobserver agreement, this agreement may be improved by training nephropathologists. These results also underscore the importance of a central review by experienced nephropathologists in clinical trials. Copyright © 2015 by the American Society of Nephrology.

  10. A 3-tier classification of cerebral arteriovenous malformations. Clinical article.

    PubMed

    Spetzler, Robert F; Ponce, Francisco A

    2011-03-01

    The authors propose a 3-tier classification for cerebral arteriovenous malformations (AVMs). The classification is based on the original 5-tier Spetzler-Martin grading system, and reflects the treatment paradigm for these lesions. The implications of this modification in the literature are explored. Class A combines Grades I and II AVMs, Class B are Grade III AVMs, and Class C combines Grades IV and V AVMs. Recommended management is surgery for Class A AVMs, multimodality treatment for Class B, and observation for Class C, with exceptions to the latter including recurrent hemorrhages and progressive neurological deficits. To evaluate whether combining grades is warranted from the perspective of surgical outcomes, the 3-tier system was applied to 1476 patients from 7 surgical series in which results were stratified according to Spetzler-Martin grades. Pairwise comparisons of individual Spetzler-Martin grades in the series analyzed showed the fewest significant differences (p < 0.05) in outcomes between Grades I and II AVMs and between Grades IV and V AVMs. In the pooled data analysis, significant differences in outcomes were found between all grades except IV and V (p = 0.38), and the lowest relative risks were found between Grades I and II (1.066) and between Grades IV and V (1.095). Using the pooled data, the predictive accuracies for surgical outcomes of the 5-tier and 3-tier systems were equivalent (receiver operating characteristic curve area 0.711 and 0.713, respectively). Combining Grades I and II AVMs and combining Grades IV and V AVMs is justified in part because the differences in surgical results between these respective pairs are small. The proposed 3-tier classification of AVMs offers simplification of the Spetzler-Martin system, provides a guide to treatment, and is predictive of outcome. The revised classification not only simplifies treatment recommendations; by placing patients into 3 as opposed to 5 groups, statistical power is markedly increased for series comparisons.

  11. 37 CFR 2.6 - Trademark fees.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... filing an application on paper, per class $375.00 (ii) For filing an application through TEAS, per class $325.00 (iii) For filing a TEAS Plus application under § 2.22, per class $275.00 (iv) Additional...

  12. Cloning and heterologous expression of a novel subgroup of class IV polyhydroxyalkanoate synthase genes from the genus Bacillus.

    PubMed

    Mizuno, Kouhei; Kihara, Takahiro; Tsuge, Takeharu; Lundgren, Benjamin R; Sarwar, Zaara; Pinto, Atahualpa; Nomura, Christopher T

    2017-01-01

    Many microorganisms harbor genes necessary to synthesize biodegradable plastics known as polyhydroxyalkanoates (PHAs). We surveyed a genomic database and discovered a new cluster of class IV PHA synthase genes (phaRC). These genes are different in sequence and operon structure from any previously reported PHA synthase. The newly discovered PhaRC synthase was demonstrated to produce PHAs in recombinant Escherichia coli.

  13. Incipient class II mixed valency in a plutonium solid-state compound

    NASA Astrophysics Data System (ADS)

    Cary, Samantha K.; Galley, Shane S.; Marsh, Matthew L.; Hobart, David L.; Baumbach, Ryan E.; Cross, Justin N.; Stritzinger, Jared T.; Polinski, Matthew J.; Maron, Laurent; Albrecht-Schmitt, Thomas E.

    2017-09-01

    Electron transfer in mixed-valent transition-metal complexes, clusters and materials is ubiquitous in both natural and synthetic systems. The degree to which intervalence charge transfer (IVCT) occurs, dependent on the degree of delocalization, places these within class II or III of the Robin-Day system. In contrast to the d-block, compounds of f-block elements typically exhibit class I behaviour (no IVCT) because of localization of the valence electrons and poor spatial overlap between metal and ligand orbitals. Here, we report experimental and computational evidence for delocalization of 5f electrons in the mixed-valent PuIII/PuIV solid-state compound, Pu3(DPA)5(H2O)2 (DPA = 2,6-pyridinedicarboxylate). The properties of this compound are benchmarked by the pure PuIII and PuIV dipicolinate complexes, [PuIII(DPA)(H2O)4]Br and PuIV(DPA)2(H2O)3·3H2O, as well as by a second mixed-valent compound, PuIII[PuIV(DPA)3H0.5]2, that falls into class I instead. Metal-to-ligand charge transfer is involved in both the formation of Pu3(DPA)5(H2O)2 and in the IVCT.

  14. Efficacy and safety of fractional carbon dioxide laser for treatment of unwanted facial freckles in phototypes II-IV: a pilot study.

    PubMed

    El Zawahry, Bakr; Zaki, Naglaa; Hafez, Vanessa; Abdel Hay, Rania; Hay, Rania Abdel; Fahim, Aya

    2014-11-01

    Facial freckles are a cosmetic concern to Egyptians, particularly young females. Several therapeutic lines exist with variable response rates and limitations. Fractional carbon dioxide (FCO2) laser provides minimal ablation and therefore less down time and less side effects. The efficacy and safety of this laser technology have still not been studied in freckles. The aim of this study is to assess the efficacy and safety of FCO2 laser in the treatment of unwanted facial freckles in Egyptians. Twenty patients undergone a single session of FCO2 laser and then were followed up clinically a month later. Photographs were taken before treatment and at follow-up visit and were assessed by three blinded investigators. Percent of global improvement was measured on a 4-point grading scale. Patient's satisfaction and adverse events were recorded. Two patients (10 %) showed grade 1 improvement, while eight patients (40 %) showed grade 2 improvement. Nine patients (45 %) showed grade 3 improvement, and only one patient (5 %) showed grade 4 improvement. FCO2 laser resurfacing is effective and safe in treatment of facial freckles in skin phototypes II-IV. It can offer a more practical alternative to topical treatments, and a cheaper alternative to Q-switched lasers.

  15. Thermographic and clinical evaluation of 808-nm laser photobiomodulation effects after third molar extraction.

    PubMed

    Pedreira, Amanda A; Wanderley, Flavia G; Sa, Maira F; Viena, Camila S; Perez, Adriano; Hoshi, Ryuichi; Leite, Marcia P; Reis, Silvia R; Medrado, Alena P

    2016-08-01

    A randomized, blind, controlled clinical study was conducted with a convenience sample of 24 patients to evaluate the effectiveness of an aluminum gallium arsenide (AlGaAs) infrared laser 808 nm after third molar extraction by the use of infrared thermography technique. Patients were divided into four groups: erupted third molars were extracted from the patients in Group I and Group II, and impacted third molars were extracted from the patients in Group III and Group IV. Group I and Group III received mock laser therapy in which the device was powered off, and Group II and Group IV were exposed to laser light. Postoperative clinical parameters related to the third molar extraction were evaluated; these parameters included pain, trismus and edema. Circulatory patterns were also evaluated by infrared thermography that exhibited local temperature coefficient at different postoperative periods. A slight improvement was observed for swelling, pain and trismus in patients who received laser irradiation, although the differences were not statistically significant (P>0.05). Laser therapy had a significant influence on the local circulation in the area near the temporomandibular joint, as determined by infrared thermography (P<0.05). Laser therapy was able to change the local circulation, although it did not significantly influence swelling, pain or trismus during the postoperative period.

  16. Assessment of the influence of Laser phototherapy on the bone repair process of complete fractures in tibiae of rabbits stabilized with semi-rigid internal fixation treated with or without MTA graft: a histological study

    NASA Astrophysics Data System (ADS)

    Soares, Luiz G. P.; Silva, Aline C. P.; Silva, Anna Paula L. T.; Neves, Bruno Luiz R. C.; Santos, Nicole R. S.; dos Santos, Jean N.; Pinheiro, Antonio L. B.

    2016-03-01

    Beside biomaterials, Laser phototherapy has shown positive effects as auxiliary therapy in bone repair process, especially when involving large bone losses. The aim of this histological study was to evaluate, by light microscopy, the influence of laser phototherapy on the repair of complete tibial fractures in rabbits treated or not with semi-rigid internal fixation and Mineral Trioxide Aggregate - MTA graft. Twelve Rabbits were randomly divided into four groups with three animals each. After general anesthesia, complete fractures were created in one tibia with a carborundum disk. All animals (groups I-IV) had the fracture stabilized with semi-rigid fixation (wire osteosynthesis - WO). Group I was routinely fixed with WO; groups II and IV fracture was filled by blood clot and MTA implant. In Groups III and IV fracture was filled by blood clot and further irradiated with laser (λ780 nm, 70 mW, CW, Φ = 0.04 cm2, 20.4 J/cm2, per session, t = 300s, 142.8 J/cm2 per treatment). The phototherapy protocol was applied immediately after the surgery and repeated each 48 hours during 15 days. Animal death occurred on the 30th postoperative day. After removal of the specimens, the samples were routinely processed, stained with HE and evaluated by light microscopy. Histologically, the group treated with MTA graft and irradiated with laser showed the fracture filled by a more organized and mature trabecular bone, when compared with all other groups. From the results of the present study, it may be concluded that the association of Laser phototherapy + MTA graft in fractures treated with WO improved bone repair when compared with fractures treated only with WO.

  17. Organization and variation analysis of 5S rDNA in different ploidy-level hybrids of red crucian carp × topmouth culter.

    PubMed

    He, Weiguo; Qin, Qinbo; Liu, Shaojun; Li, Tangluo; Wang, Jing; Xiao, Jun; Xie, Lihua; Zhang, Chun; Liu, Yun

    2012-01-01

    Through distant crossing, diploid, triploid and tetraploid hybrids of red crucian carp (Carassius auratus red var., RCC♀, Cyprininae, 2n = 100) × topmouth culter (Erythroculter ilishaeformis Bleeker, TC♂, Cultrinae, 2n = 48) were successfully produced. Diploid hybrids possessed 74 chromosomes with one set from RCC and one set from TC; triploid hybrids harbored 124 chromosomes with two sets from RCC and one set from TC; tetraploid hybrids had 148 chromosomes with two sets from RCC and two sets from TC. The 5S rDNA of the three different ploidy-level hybrids and their parents were sequenced and analyzed. There were three monomeric 5S rDNA classes (designated class I: 203 bp; class II: 340 bp; and class III: 477 bp) in RCC and two monomeric 5S rDNA classes (designated class IV: 188 bp, and class V: 286 bp) in TC. In the hybrid offspring, diploid hybrids inherited three 5S rDNA classes from their female parent (RCC) and only class IV from their male parent (TC). Triploid hybrids inherited class II and class III from their female parent (RCC) and class IV from their male parent (TC). Tetraploid hybrids gained class II and class III from their female parent (RCC), and generated a new 5S rDNA sequence (designated class I-N). The specific paternal 5S rDNA sequence of class V was not found in the hybrid offspring. Sequence analysis of 5S rDNA revealed the influence of hybridization and polyploidization on the organization and variation of 5S rDNA in fish. This is the first report on the coexistence in vertebrates of viable diploid, triploid and tetraploid hybrids produced by crossing parents with different chromosome numbers, and these new hybrids are novel specimens for studying the genomic variation in the first generation of interspecific hybrids, which has significance for evolution and fish genetics.

  18. Latent class instrumental variables: a clinical and biostatistical perspective.

    PubMed

    Baker, Stuart G; Kramer, Barnett S; Lindeman, Karen S

    2016-01-15

    In some two-arm randomized trials, some participants receive the treatment assigned to the other arm as a result of technical problems, refusal of a treatment invitation, or a choice of treatment in an encouragement design. In some before-and-after studies, the availability of a new treatment changes from one time period to this next. Under assumptions that are often reasonable, the latent class instrumental variable (IV) method estimates the effect of treatment received in the aforementioned scenarios involving all-or-none compliance and all-or-none availability. Key aspects are four initial latent classes (sometimes called principal strata) based on treatment received if in each randomization group or time period, the exclusion restriction assumption (in which randomization group or time period is an instrumental variable), the monotonicity assumption (which drops an implausible latent class from the analysis), and the estimated effect of receiving treatment in one latent class (sometimes called efficacy, the local average treatment effect, or the complier average causal effect). Since its independent formulations in the biostatistics and econometrics literatures, the latent class IV method (which has no well-established name) has gained increasing popularity. We review the latent class IV method from a clinical and biostatistical perspective, focusing on underlying assumptions, methodological extensions, and applications in our fields of obstetrics and cancer research. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Teradiode's high brightness semiconductor lasers

    NASA Astrophysics Data System (ADS)

    Huang, Robin K.; Chann, Bien; Burgess, James; Lochman, Bryan; Zhou, Wang; Cruz, Mike; Cook, Rob; Dugmore, Dan; Shattuck, Jeff; Tayebati, Parviz

    2016-03-01

    TeraDiode is manufacturing multi-kW-class ultra-high brightness fiber-coupled direct diode lasers for industrial applications. A fiber-coupled direct diode laser with a power level of 4,680 W from a 100 μm core diameter, <0.08 numerical aperture (NA) output fiber at a single center wavelength was demonstrated. Our TeraBlade industrial platform achieves world-record brightness levels for direct diode lasers. The fiber-coupled output corresponds to a Beam Parameter Product (BPP) of 3.5 mm-mrad and is the lowest BPP multi-kW-class direct diode laser yet reported. This laser is suitable for industrial materials processing applications, including sheet metal cutting and welding. This 4-kW fiber-coupled direct diode laser has comparable brightness to that of industrial fiber lasers and CO2 lasers, and is over 10x brighter than state-of-the-art direct diode lasers. We have also demonstrated novel high peak power lasers and high brightness Mid-Infrared Lasers.

  20. Influence of Er:YAG laser irradiation distance on the bond strength of a restorative system to enamel.

    PubMed

    Chimello-Sousa, Daniela Thomazatti; de Souza, Aline Evangelista; Chinelatti, Michelle Alexandra; Pécora, Jesus Djalma; Palma-Dibb, Regina Guenka; Milori Corona, Silmara Aparecida

    2006-03-01

    The aim of the present study was to investigate in vitro the effect of Er:YAG laser on bonding to enamel, varying the irradiation distance. Tensile bond strength of an adhesive restorative system to non-irradiated and irradiated enamel surfaces was evaluated. Thirty caries-free human third molars were sectioned in mesio-distal direction and embedded in acrylic resin. Enamel was flattened, and a 3-mm-diameter bonding area was demarcated. Specimens were randomly assigned into six groups: groups I-V were treated with the Er:YAG laser (80 mJ/2 Hz), varying the irradiation distance (11, 12 mm-focused, 14, 16 and 17 mm, respectively), followed by 35% phosphoric acid etching. Control group (VI) received treatment with phosphoric acid alone. Single Bond adhesive system was applied on the conditioned enamel, and composite resin cones, bonded to enamel, were fabricated with Z250. After storage, samples were tested in tensile to failure (50 kgf and 0.5 mm/min). Means in MPa were: I-9.67 (+/-3.44); II-13.29 (+/-2.65); III-13.33 (+/-2.22); IV-14.87 (+/-3.58); V-16.43 (+/-4.52); VI-22.90 (+/-3.03). ANOVA and Tukey test revealed statistically significant decrease of bond strength in group I (P < 0.05). Groups II-IV presented similar results, as did groups IV and V. Control group (VI) yielded the best overall performance (P < 0.05). Er:YAG laser irradiation adversely affected adhesion to enamel. However, bond strength was influenced by the irradiation distance, thus being stronger with the increase of distance to the target tissue.

  1. Direct Bandgap Group IV Materials

    DTIC Science & Technology

    2016-01-21

    devices. In this project, we have accomplished (a) direct bandgap group IV materials of GeSn, (b) GeSn-based planar light - emitting diode operated at near...devices of planar light emitting diode , detector and laser ” 6/12/2015 PI and Co-PI information: - Name of Principal Investigators: Prof. H. H. Cheng...IV materials of GeSn, (b) GeSn-based planar light - emitting diode operated at near infrared with direct emission, and (c) the first planar

  2. Optimal and safe treatment of spider leg veins measuring less than 1.5 mm on skin type IV patients, using repeated low-fluence Nd:YAG laser pulses after polidocanol injection.

    PubMed

    Moreno-Moraga, Javier; Hernández, Esteban; Royo, Josefina; Alcolea, Justo; Isarría, M Jose; Pascu, Mihail Lucian; Smarandache, Adriana; Trelles, Mario

    2013-05-01

    Treatment of micro-veins of less than 1.5 mm with laser and with chemical sclerosis is technically challenging because of their difficulty to remedy. Laser treatment is even more difficult when dark phototypes are involved.Three groups of 30 patients each, skin type IV, and vessels measuring less than 1.5 mm in diameter, were enrolled for two treatment sessions 8 weeks apart: group A, polidocanol (POL) micro-foam injection; group B, Nd:YAG laser alone; and group C, laser after POL injection. Repeated 8-Hz low-fluence pulses, moving the hand piece over a 3-cm vein segment with an average of five laser passes maximum and with a total time irradiation of 1 s were used. Sixteen weeks after the second treatment, statistically, degree of clearance after examining photographs and patients satisfaction index, plotted on a visual analogue scale and comparing results of all three groups, results were significantly better for group C (p<0.0001). No significant differences in complications were noticed between the three groups. Efficacy of combining POL and laser proved safe and satisfactory in 96 % of patients using low-fluence laser pulses with a total cumulative energy in the 3 cm venous segment, lower than that of conventional treatment. Very few and transient complications were observed. POL foam injection followed by laser pulses is safe and efficient for vein treatment in dark-skinned patients.

  3. Laser ablation for mesial temporal lobe epilepsy: Surgical and cognitive outcomes with and without mesial temporal sclerosis.

    PubMed

    Donos, Cristian; Breier, Joshua; Friedman, Elliott; Rollo, Patrick; Johnson, Jessica; Moss, Lauren; Thompson, Stephen; Thomas, Melissa; Hope, Omotola; Slater, Jeremy; Tandon, Nitin

    2018-06-12

    Laser interstitial thermal therapy (LITT) is a minimally invasive surgical technique for focal epilepsy. A major appeal of LITT is that it may result in fewer cognitive deficits, especially when targeting dominant hemisphere mesial temporal lobe (MTL) epilepsy. To evaluate this, as well as to determine seizure outcomes following LITT, we evaluated the relationships between ablation volumes and surgical or cognitive outcomes in 43 consecutive patients undergoing LITT for MTL epilepsy. All patients underwent unilateral LITT targeting mesial temporal structures. FreeSurfer software was used to derive cortical and subcortical segmentation of the brain (especially subregions of the MTL) using preoperative magnetic resonance imaging (MRI). Ablation volumes were outlined using a postablation T1-contrasted MRI. The percentages of the amygdala, hippocampus, and entorhinal cortex ablated were quantified objectively. The volumetric measures were regressed against changes in neuropsychological performance before and after surgery, RESULTS: A median of 73.7% of amygdala, 70.9% of hippocampus, and 28.3% of entorhinal cortex was ablated. Engel class I surgical outcome was obtained in 79.5% and 67.4% of the 43 patients at 6 and 20.3 months of follow-up, respectively. No significant differences in surgical outcomes were found across patient subgroups (hemispheric dominance, hippocampal sclerosis, or need for intracranial evaluation). Furthermore, no significant differences in volumes ablated were found between patients with Engel class IA vs Engel class II-IV outcomes. In patients undergoing LITT in the dominant hemisphere, a decline in verbal and narrative memory, but not in naming function was noted. Seizure-free outcomes following LITT may be comparable in carefully selected patients with and without MTS, and these outcomes are comparable with outcomes following microsurgical resection. Failures may result from non-mesial components of the epileptogenic network that are not affected by LITT. Cognitive declines following MTL-LITT are modest, and principally affect memory processes. Wiley Periodicals, Inc. © 2018 International League Against Epilepsy.

  4. Bringing PW-class lasers to XFELs (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Tomizawa, Hiromitsu

    2017-06-01

    Experimental researches using high power optical lasers combined with free electron lasers (FELs) open new frontiers in high energy density (HED) sciences. Probing and pumping capabilities are dramatically improved due to the brightness of the XFEL pulses with ultrafast duration. Besides, the peak intensities of Ti:sapphire laser Chirped Pulse Amplification (CPA) systems reach petawatt (PW)-class with operating in few tens of fs and commercially available at a few Hz of repetition rate. We have been developing an experimental platform for HED sciences using high power, high intensity optical lasers at the XFEL facility, SACLA.Currently, an experimental platform with a dual 0.5 PW Ti:Sapphire laser system is under beam commissioning for experiments combined with the SACLA's x-ray beam for research objectives that require more peak power in the optical laser pulses with a few tens of fs. The optical laser system is designed to deliver two laser beams simultaneously with the maximum power of 0.5 PW in each into a target chamber located in an experimental hutch 6 (EH6) at BL2, which was recently commissioned as a SACLA's 2nd hard x-ray beamline. A focusing capability using sets of compound refractive lenses will be applied to increase the x-ray fluence on the target sample. One of the most key issues for the integrated experimental platform is development of diagnostics that meets requirements both from the high power laser (e.g. resistance to harsh environments) and from the XFEL (e.g. adaptation to the available data acquisition system). The status and future perspective of the development including automatic laser alignment systems will be reported in the presentation. We will discuss the most promising and important new physics experiments that will be enabled by the combination of PW-class lasers and the world-class FEL's x-ray beam.

  5. 40 CFR Appendix I to Part 1054 - Summary of Previous Emission Standards

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Engines (g/kW-hr) a Engine displacement class HC NOX CO Class III 295 5.36 805 Class IV 241 5.36 805 Class...—Phase 2 Emission Standards for Handheld Engines (g/kW-hr) a Engine displacement class HC+NOX CO Class...-hr) a Engine displacement class HC+NOX CO Class I 16.1 519 Class II 13.4 519 a Phase 1 standards are...

  6. 40 CFR Appendix I to Part 1054 - Summary of Previous Emission Standards

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Engines (g/kW-hr) a Engine displacement class HC NOX CO Class III 295 5.36 805 Class IV 241 5.36 805 Class...—Phase 2 Emission Standards for Handheld Engines (g/kW-hr) a Engine displacement class HC+NOX CO Class...-hr) a Engine displacement class HC+NOX CO Class I 16.1 519 Class II 13.4 519 a Phase 1 standards are...

  7. 40 CFR Appendix I to Part 1054 - Summary of Previous Emission Standards

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Engines (g/kW-hr) a Engine displacement class HC NOX CO Class III 295 5.36 805 Class IV 241 5.36 805 Class...—Phase 2 Emission Standards for Handheld Engines (g/kW-hr) a Engine displacement class HC+NOX CO Class...-hr) a Engine displacement class HC+NOX CO Class I 16.1 519 Class II 13.4 519 a Phase 1 standards are...

  8. 40 CFR Appendix I to Part 1054 - Summary of Previous Emission Standards

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Engines (g/kW-hr) a Engine displacement class HC NOX CO Class III 295 5.36 805 Class IV 241 5.36 805 Class...—Phase 2 Emission Standards for Handheld Engines (g/kW-hr) a Engine displacement class HC+NOX CO Class...-hr) a Engine displacement class HC+NOX CO Class I 16.1 519 Class II 13.4 519 a Phase 1 standards are...

  9. 40 CFR Appendix I to Part 1054 - Summary of Previous Emission Standards

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Engines (g/kW-hr) a Engine displacement class HC NOX CO Class III 295 5.36 805 Class IV 241 5.36 805 Class...—Phase 2 Emission Standards for Handheld Engines (g/kW-hr) a Engine displacement class HC+NOX CO Class...-hr) a Engine displacement class HC+NOX CO Class I 16.1 519 Class II 13.4 519 a Phase 1 standards are...

  10. Clinical dental application of Er:YAG laser for Class V cavity preparation.

    PubMed

    Matsumoto, K; Nakamura, Y; Mazeki, K; Kimura, Y

    1996-06-01

    Following the development of the ruby laser by Maiman in 1960, the Nd:YAG laser, the CO2 laser, the semiconductor laser, the He-Ne laser, excimer lasers, the argon laser, and finally the Er:YAG laser capable of cutting hard tissue easily were developed and have come to be applied clinically. In the present study, the Er:YAG laser emitting at a wavelength of 2.94 microns developed by Luxar was used for the clinical preparation of class V cavities. Parameters of 8 Hz and approx. 250 mJ/pulse maximum output were used for irradiation. Sixty teeth of 40 patients were used in this clinical study. The Er:YAG laser used in this study was found to be a system suitable for clinical application. No adverse reaction was observed in any of the cases. Class V cavity preparation was performed without inducing any pain in 48/60 cases (80%). All of the 12 cases that complained of mild or severe intraoperative pain had previously complained of cervical dentin hypersensibility during the preoperative examination. Cavity preparation was completed with this laser system in 58/60 cases (91.7%). No treatment-related clinical problems were observed during the follow-up period of approx. 30 days after cavity preparation and resin filling. Cavity preparation took between approx. 10 sec and 3 min and was related more or less to cavity size and depth. Overall clinical evaluation showed no safety problem with very good rating in 49 cases (81.7%).

  11. 14 CFR 61.5 - Certificates and ratings issued under this part.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...-control aircraft. (2) Airplane class ratings— (i) Single-engine land. (ii) Multiengine land. (iii) Single-engine sea. (iv) Multiengine sea. (3) Rotorcraft class ratings— (i) Helicopter. (ii) Gyroplane. (4) Lighter-than-air class ratings— (i) Airship. (ii) Balloon. (5) Weight-shift-control aircraft class ratings...

  12. 14 CFR 61.5 - Certificates and ratings issued under this part.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...-control aircraft. (2) Airplane class ratings— (i) Single-engine land. (ii) Multiengine land. (iii) Single-engine sea. (iv) Multiengine sea. (3) Rotorcraft class ratings— (i) Helicopter. (ii) Gyroplane. (4) Lighter-than-air class ratings— (i) Airship. (ii) Balloon. (5) Weight-shift-control aircraft class ratings...

  13. 14 CFR 61.5 - Certificates and ratings issued under this part.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...-control aircraft. (2) Airplane class ratings— (i) Single-engine land. (ii) Multiengine land. (iii) Single-engine sea. (iv) Multiengine sea. (3) Rotorcraft class ratings— (i) Helicopter. (ii) Gyroplane. (4) Lighter-than-air class ratings— (i) Airship. (ii) Balloon. (5) Weight-shift-control aircraft class ratings...

  14. Coupled-resonator vertical-cavity lasers with two active gain regions

    DOEpatents

    Fischer, Arthur J.; Choquette, Kent D.; Chow, Weng W.

    2003-05-20

    A new class of coupled-resonator vertical-cavity semiconductor lasers has been developed. These lasers have multiple resonant cavities containing regions of active laser media, resulting in a multi-terminal laser component with a wide range of novel properties.

  15. Resurfacing of Facial Acne Scars With a New Variable-Pulsed Er:YAG Laser in Fitzpatrick Skin Types IV and V

    PubMed Central

    Chathra, Namitha; Mysore, Venkataram

    2018-01-01

    Introduction: The Er:YAG laser, considered to be less effective than CO2 laser in its traditional form, in its new modulated version has variable pulse technology that is claimed to be superior to the earlier versions of the laser. Aim: The aim of the study was to check efficacy and safety of the new variable square pulse (VSP) Er:YAG laser in the management of acne scar in patients with Fitzpatrick skin types IV and V. Materials and Methods: This retrospective study consisted of 80 patients (Fitzpatrick skin types IV and V) with atrophic and hypertrophic facial acne scars. Records of the patients who had undergone four treatment sessions with VSP technology equipped with Er:YAG laser were extracted. Each patient had undergone a minimum of four sessions. Fractional mode at medium laser pulse (SP) and long pulse (LP) was employed for the depressed center of the scars to stimulate neocollagenogenesis. Short laser pulse (MSP) in nonfractionated mode was used for ablating the raised scar border and hypertrophic scars. Goodman and Baron global scarring grading system was used for qualitative and quantitative assessments. Patient’s satisfaction to the treatment and observer’s assessment of improvement (based on photographs) was graded as poor (<25% improvement), fair (25–50% improvement), good (51–75% improvement), and excellent (>75% improvement). Results: At the end of the four sessions, the number of patients in grade IV postacne scarring reduced from 16 to 2 and that in grade III from 47 to 29. The mean score significantly dropped from 36.94 to 27.5. Subjective assessment revealed that 78 of 80 patients had noticed more than 25% improvement, with 50 of them showing more than 50% improvement at the end of four sessions. Eight patients perceived an excellent response and 42 reported a good response. This is notably higher than the observer’s grading, which showed an excellent response in only 2 patients and a good response in 35. Adverse effects were limited to prolonged erythema (two patients), prolonged crusting (one patient), and postinflammatory hyperpigmentation (one patient). Conclusion: Ninety-seven percent of the subjects in our study perceived at least a fair improvement. We also saw a significant change in the objective score with a fall of the mean quantitative score from 36.94 to 27.15. This underscores the new variable-pulsed Er:YAG laser’s effectiveness in the treatment of acne scars. It also has the added advantage of lesser adverse events and faster healing. PMID:29731588

  16. Ultrafast Passive Shields for Laser and Ballistic Protection

    DTIC Science & Technology

    1991-07-15

    chemically polymerized P(DPA)) as a binder, and these were tested for ablation (i.e. laser damage threshold ) limits. Table IV below summarizes these results...50, 100, 250 and 500 AJ/pulse o 1.G, 2.5, 5.0 mJ/pulse. The following energies were used for the preliminary laser damage threshold tests: o 2.5, 5.0...these were tested for ablation (i.e. laser damage threshold ) limits. Table VI summarizes these results which are all for tests in the absence of an iris

  17. High Efficiency, Room Temperature Mid-Infrared Semiconductor Laser Development for IR Countermeasures

    DTIC Science & Technology

    2009-05-01

    voltage (I-V) characteristics of several infrared LEDs, including a type-II W-well laser grown by Molecular Beam Epitaxy at Naval Research Laboratory...Injection Cavity (OPIC) lasers includes >4 um emission from a broadband laser and the measurement of spatial and temporal beam profiles. From August 2006...argon) at 15 mTorr, 400W ICP, and 70W RIE power, with an etch rate of 300 nm/min. Epitaxial ZnO layers were plasma etched using BCl3/SF0gas mixtures

  18. Long-term efficacy of linear-scanning 808 nm diode laser for hair removal compared to a scanned alexandrite laser.

    PubMed

    Grunewald, Sonja; Bodendorf, Marc Oliver; Zygouris, Alexander; Simon, Jan Christoph; Paasch, Uwe

    2014-01-01

    Alexandrite and diode lasers are commonly used for hair removal. To date, the available spot sizes and repetition rates are defining factors in terms of penetration depth, treatment speed, and efficacy. Still, larger treatment areas and faster systems are desirable. To compare the efficacy, tolerability, and subject satisfaction of a continuously linear-scanning 808 nm diode laser with an alexandrite 755 nm laser for axillary hair removal. A total of 31 adults with skin types I-IV received 6 treatments at 4-week intervals with a 755 nm alexandrite laser (right axilla) and a continuously linear-scanning 808 nm diode laser (left axilla). Axillary hair density was assessed using a computerized hair detection system. There was a significant reduction in axillary hair after the 6th treatment (P < 0.05) on both sides (left, 808 nm: hair clearance of 72.16%; right, 755 nm: hair clearance of 71.30%). The difference in reduction between the two lasers was not significant, but both were persistant at 18 months follow-up (left: hair clearance of 73.71%; right: hair clearance of 71.90%). Erythema and perifollicular edema were more common after alexandrite laser treatment, but all side effects were transient. While 62.50% of patients reported more pain in response to treatment with the new diode laser, all patients rated treatment with either laser tolerable. Treatment with either the alexandrite or the linear-scanning diode laser results in significant, comparable, persistent (at least 18 months) axillary hair reduction among individuals with skin types I-IV. © 2013 Wiley Periodicals, Inc.

  19. Hemodynamic-GUIDEd Management of Heart Failure

    ClinicalTrials.gov

    2018-03-29

    Heart Failure; Heart Failure, Systolic; Heart Failure, Diastolic; Heart Failure NYHA Class II; Heart Failure NYHA Class III; Heart Failure NYHA Class IV; Heart Failure,Congestive; Heart Failure With Reduced Ejection Fraction; Heart Failure With Normal Ejection Fraction; Heart Failure; With Decompensation

  20. The Activity of Class I-IV Alcohol Dehydrogenase Isoenzymes and Aldehyde Dehydrogenase in Bladder Cancer Cells.

    PubMed

    Orywal, Karolina; Jelski, Wojciech; Werel, Tadeusz; Szmitkowski, Maciej

    2018-01-02

    The aim of this study was to determine the differences in the activity of Alcohol Dehydrogenase (ADH) isoenzymes and Aldehyde Dehydrogenase (ALDH) in normal and cancerous bladder cells. Class III, IV of ADH and total ADH activity were measured by the photometric method and class I, II ADH and ALDH activity by the fluorometric method. Significantly higher total activity of ADH was found in both, low-grade and high-grade bladder cancer, in comparison to healthy tissues. The increased activity of total ADH in bladder cancer cells may be the cause of metabolic disorders in cancer cells, which may intensify carcinogenesis.

  1. Long-term effects of laser-imiquimod combination in the treatment of late-stage melanoma patients

    NASA Astrophysics Data System (ADS)

    Naylor, Mark F.; Le, Henry; Li, Xiaosong; Nordquist, Robert E.; Hode, Tomas; Liu, Hong; Chen, Wei R.

    2012-03-01

    Topical application of a potent immunological modulator, imiquimod, followed by laser irradiation has been used for the treatment of late-stage melanoma patients. This novel approach, laser-assisted laser immunotherapy (LIT), targets the root course of melanoma, a highly metastatic cancer. We started a phase I clinical trial in 2006 with promising initial outcomes. The laser-imiquimod combination showed significant palliative effects for these patients with multiple treatment cycles. For the returning patients, we found that the recurrent tumors were less aggressive than usually seen in untreated patients. The current protocol uses a light-absorbing dye for selective laser photothermal interaction with a non-invasive treatment mode. It has limitations for patient treatment, particularly for large, deeper tumors, and for patients with dark pigmented skins. This study provides some information on the treated patients (both stage IV and stage IV) during the past several years. We also discuss the future directions of LIT, particularly in the area of photothermal treatment mode with a new approach of interstitial irradiation. The current results in melanoma treatment using LIT indicate that the combination of photothermal therapy and immunological stimulation may hold the key for the treatment of late-stage, metastatic cancers, not only for cutaneous cancers such as melanoma and breast cancer, but also for deep and internal tumors using different operations modes such as interstitial laser irradiation.

  2. Extremely high-brightness kW-class fiber coupled diode lasers with wavelength stabilization

    NASA Astrophysics Data System (ADS)

    Huang, Robin K.; Chann, Bien; Glenn, John D.

    2011-06-01

    TeraDiode has produced ultra-high brightness fiber-coupled direct diode lasers. A fiber-coupled direct diode laser with a power level of 1,040 W from a 200 μm core diameter, 0.18 numerical aperture (NA) output fiber at a single center wavelength was demonstrated. This was achieved with a novel beam combining and shaping technique using COTS diode lasers. The fiber-coupled output corresponds to a Beam Parameter Product (BPP) of 18 mm-mrad and is the lowest BPP kW-class direct diode laser yet reported. The laser has been used to demonstrate laser cutting and welding of steel sheet metal up to 6.65 mm thick. Higher brightness fiber-coupled diode lasers, including a module with 418 W of power coupled to a 100 μm, 0.15 NA fiber, have also been demonstrated.

  3. Effects of low-level laser therapy on stem cells from human exfoliated deciduous teeth.

    PubMed

    Fernandes, Ana Paula; Junqueira, Marina de Azevedo; Marques, Nádia Carolina Teixeira; Machado, Maria Aparecida Andrade Moreira; Santos, Carlos Ferreira; Oliveira, Thais Marchini; Sakai, Vivien Thiemy

    2016-01-01

    This study aimed to evaluate the influence of different laser therapy energy densities on SHED viability and proliferation. SHED were irradiated according to the groups: I (1.2 J/cm2 - 0.5 mW - 10 s), II (2.5 J/cm2 - 10 mW - 10 s), III (3.7 J/cm2 - 15 mW - 10 s), IV (5.0 J/cm2 - 20 mW - 10 s), V (6.2 J/cm2 - 25 mW - 10 s), and VI (not irradiated - control group). Cell viability was assessed 6 and 24 h after irradiation measuring the mitochondrial activity and using the Crystal Violet assay. Cell proliferation was assessed after 24, 48, and 72 h of irradiation by SRB assay. MTT assay demonstrated differences from 6 to 24 hours after irradiation. After 24 h, groups I and IV showed higher absorbance values than those of control group. Crystal Violet assay showed statistically differences in the absorbance rate from 6 to 24 h after irradiation for groups III and VI. At 24 h after irradiation, Group III absorbance rate was greater than that of groups I, II, and IV. Group VI absorbance rate was greater than that of groups I and IV. SRB assay showed that the group I had higher rates than those of groups II, III, V, and VI, at 24 h after irradiation. After 48 h, group I exhibited the greatest cell proliferation rate followed by groups III, V, and VI. After 72 h, group III exhibited the lowest cell proliferation rate than those of groups II, IV, and V. The Low-Level Laser Therapy energy densities used in this study did not cause loss of cell viability and stimulated SHED proliferation within the parameters described in this study.

  4. Compliance of SLAC_s Laser Safety Program with OSHA Requirements for the Control of Hazardous Energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woods, Michael; /SLAC

    SLAC's COHE program requires compliance with OSHA Regulation 29CFR1910.147, 'The control of hazardous energy (lockout/tagout)'. This regulation specifies lockout/tagout requirements during service and maintenance of equipment in which the unexpected energization or start up of the equipment, or release of stored energy, could cause injury to workers. Class 3B and Class 4 laser radiation must be considered as hazardous energy (as well as electrical energy in associated equipment, and other non-beam energy hazards) in laser facilities, and therefore requires careful COHE consideration. This paper describes how COHE is achieved at SLAC to protect workers against unexpected Class 3B or Classmore » 4 laser radiation, independent of whether the mode of operation is normal, service, or maintenance.« less

  5. Rectified diode response of a multimode quantum cascade laser integrated terahertz transceiver.

    PubMed

    Dyer, Gregory C; Norquist, Christopher D; Cich, Michael J; Grine, Albert D; Fuller, Charles T; Reno, John L; Wanke, Michael C

    2013-02-25

    We characterized the DC transport response of a diode embedded in a THz quantum cascade laser as the laser current was changed. The overall response is described by parallel contributions from the rectification of the laser field due to the non-linearity of the diode I-V and from thermally activated transport. Sudden jumps in the diode response when the laser changes from single mode to multi-mode operation, with no corresponding jumps in output power, suggest that the coupling between the diode and laser field depends on the spatial distribution of internal fields. The results demonstrate conclusively that the internal laser field couples directly to the integrated diode.

  6. Independent Review of the Defense Logistics Agencys Roles and Missions

    DTIC Science & Technology

    2014-12-01

    remaining wholesale consumables missions of tires, packaged petroleum, oils , and lubricants, and gases and cylinders were transferred from the...housekeeping supplies and equipment. Class III: Petroleum, oils , and lubricants. Class IV: Construction materials. Class V: Ammunition. Class VI...own appropriated funds that are deposited 9 The Construction and Equipment program within DLA Troop Support provides some Class VII non- weapons

  7. Usefulness of the brain natriuretic peptide to atrial natriuretic peptide ratio in determining the severity of mitral regurgitation.

    PubMed

    Shimamoto, Ken; Kusumoto, Miyako; Sakai, Rieko; Watanabe, Hirota; Ihara, Syunichi; Koike, Natsuka; Kawana, Masatoshi

    2007-03-15

    Atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) levels were characterized in subjects with mitral regurgitation (MR). Sixty-two cases of moderate or severe chronic MR were studied. The blood levels of neurohormonal factors were stratified by the known MR prognostic factors of New York Heart Association (NYHA) functional class, left ventricular end-diastolic diameters, left ventricular end-systolic diameter (LVDs), ejection fraction (EF), left atrial diameter and presence of atrial fibrillation (AF). ANP levels were higher in NYHA class II and lower in classes I and III/IV (P=0.0206). BNP levels were higher in NYHA class II than class I (P=0.0355). The BNP/ANP ratio was significantly higher in NYHA classes II and III/IV than in class I (P=0.0007). To differentiate between NYHA classes I/II and III/IV, a cut-off BNP/ANP ratio of 2.97 produced a sensitivity of 78% and specificity of 87%. Compared with subjects in sinus rhythm, patients with AF had an enlarged left atrium and lower ANP levels. The BNP/ANP ratio correlated significantly with left atrial diameter, LVDs and EF (r=0.429, P=0.0017; r=0.351, P=0.0117; and r=-0.349, P=0.0122; respectively), and was significantly higher among all the known operative indications for MR tested (LVDs 45 mm or more, EF 60% or less, NYHA class II or greater and AF; P=0.0073, P=0.003, P=0.0102 and P=0.0149, respectively). In chronic MR, levels of ANP and BNP, and the BNP/ANP ratio are potential indicators of disease severity.

  8. Redo surgery risk in patients with cardiac prosthetic valve dysfunction

    PubMed Central

    Maciejewski, Marek; Piestrzeniewicz, Katarzyna; Bielecka-Dąbrowa, Agata; Piechowiak, Monika; Jaszewski, Ryszard

    2011-01-01

    Introduction The aim of the study was to analyse the risk factors of early and late mortality in patients undergoing the first reoperation for prosthetic valve dysfunction. Material and methods A retrospective observational study was performed in 194 consecutive patients (M = 75, F = 119; mean age 53.2 ±11 years) with a mechanical prosthetic valve (n = 103 cases; 53%) or bioprosthesis (91; 47%). Univariate and multivariate Cox statistical analysis was performed to determine risk factors of early and late mortality. Results The overall early mortality was 18.6%: 31.4% in patients with symptoms of NYHA functional class III-IV and 3.4% in pts in NYHA class I-II. Multivariate analysis identified symptoms of NYHA class III-IV and endocarditis as independent predictors of early mortality. The overall late mortality (> 30 days) was 8.2% (0.62% year/patient). Multivariate analysis identified age at the time of reoperation as a strong independent predictor of late mortality. Conclusions Reoperation in patients with prosthetic valves, performed urgently, especially in patients with symptoms of NYHA class III-IV or in the case of endocarditis, bears a high mortality rate. Risk of planned reoperation, mostly in patients with symptoms of NYHA class I-II, does not differ from the risk of the first operation. PMID:22291767

  9. The Capsicum annuum class IV chitinase ChitIV interacts with receptor-like cytoplasmic protein kinase PIK1 to accelerate PIK1-triggered cell death and defence responses

    PubMed Central

    Kim, Dae Sung; Kim, Nak Hyun; Hwang, Byung Kook

    2015-01-01

    The pepper receptor-like cytoplasmic protein kinase, CaPIK1, which mediates signalling of plant cell death and defence responses was previously identified. Here, the identification of a class IV chitinase, CaChitIV, from pepper plants (Capsicum annuum), which interacts with CaPIK1 and promotes CaPIK1-triggered cell death and defence responses, is reported. CaChitIV contains a signal peptide, chitin-binding domain, and glycol hydrolase domain. CaChitIV expression was up-regulated by Xanthomonas campestris pv. vesicatoria (Xcv) infection. Notably, avirulent Xcv infection rapidly induced CaChitIV expression in pepper leaves. Bimolecular fluorescence complementation and co-immunoprecipitation revealed that CaPIK1 interacts with CaChitIV in planta, and that the CaPIK1–CaChitIV complex is localized mainly in the cytoplasm and plasma membrane. CaChitIV is also localized in the endoplasmic reticulum. Transient co-expression of CaChitIV with CaPIK1 enhanced CaPIK1-triggered cell death response and reactive oxygen species (ROS) and nitric oxide (NO) bursts. Co-silencing of both CaChitIV and CaPIK1 in pepper plants conferred enhanced susceptibility to Xcv infection, which was accompanied by a reduced induction of cell death response, ROS and NO bursts, and defence response genes. Ectopic expression of CaPIK1 in Arabidopsis enhanced basal resistance to Hyaloperonospora arabidopsidis infection. Together, the results suggest that CaChitIV positively regulates CaPIK1-triggered cell death and defence responses through its interaction with CaPIK1. PMID:25694549

  10. The Capsicum annuum class IV chitinase ChitIV interacts with receptor-like cytoplasmic protein kinase PIK1 to accelerate PIK1-triggered cell death and defence responses.

    PubMed

    Kim, Dae Sung; Kim, Nak Hyun; Hwang, Byung Kook

    2015-04-01

    The pepper receptor-like cytoplasmic protein kinase, CaPIK1, which mediates signalling of plant cell death and defence responses was previously identified. Here, the identification of a class IV chitinase, CaChitIV, from pepper plants (Capsicum annuum), which interacts with CaPIK1 and promotes CaPIK1-triggered cell death and defence responses, is reported. CaChitIV contains a signal peptide, chitin-binding domain, and glycol hydrolase domain. CaChitIV expression was up-regulated by Xanthomonas campestris pv. vesicatoria (Xcv) infection. Notably, avirulent Xcv infection rapidly induced CaChitIV expression in pepper leaves. Bimolecular fluorescence complementation and co-immunoprecipitation revealed that CaPIK1 interacts with CaChitIV in planta, and that the CaPIK1-CaChitIV complex is localized mainly in the cytoplasm and plasma membrane. CaChitIV is also localized in the endoplasmic reticulum. Transient co-expression of CaChitIV with CaPIK1 enhanced CaPIK1-triggered cell death response and reactive oxygen species (ROS) and nitric oxide (NO) bursts. Co-silencing of both CaChitIV and CaPIK1 in pepper plants conferred enhanced susceptibility to Xcv infection, which was accompanied by a reduced induction of cell death response, ROS and NO bursts, and defence response genes. Ectopic expression of CaPIK1 in Arabidopsis enhanced basal resistance to Hyaloperonospora arabidopsidis infection. Together, the results suggest that CaChitIV positively regulates CaPIK1-triggered cell death and defence responses through its interaction with CaPIK1. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  11. Evidence That the [beta] Subunit of Chlamydia trachomatis Ribonucleotide Reductase Is Active with the Manganese Ion of Its Manganese(IV)/Iron(III) Cofactor in Site 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dassama, Laura M.K.; Boal, Amie K.; Krebs, Carsten

    2014-10-02

    The reaction of a class I ribonucleotide reductase (RNR) begins when a cofactor in the {beta} subunit oxidizes a cysteine residue {approx}35 {angstrom} away in the {alpha} subunit, generating a thiyl radical. In the class Ic enzyme from Chlamydia trachomatis (Ct), the cysteine oxidant is the Mn{sup IV} ion of a Mn{sup IV}/Fe{sup III} cluster, which assembles in a reaction between O{sub 2} and the Mn{sup II}/Fe{sup II} complex of {beta}. The heterodinuclear nature of the cofactor raises the question of which site, 1 or 2, contains the Mn{sup IV} ion. Because site 1 is closer to the conserved locationmore » of the cysteine-oxidizing tyrosyl radical of class Ia and Ib RNRs, we suggested that the Mn{sup IV} ion most likely resides in this site (i.e., {sup 1}Mn{sup IV}/{sup 2}Fe{sup III}), but a subsequent computational study favored its occupation of site 2 ({sup 1}Fe{sup III}/{sup 2}Mn{sup IV}). In this work, we have sought to resolve the location of the Mn{sup IV} ion in Ct RNR-{beta} by correlating X-ray crystallographic anomalous scattering intensities with catalytic activity for samples of the protein reconstituted in vitro by two different procedures. In samples containing primarily Mn{sup IV}/Fe{sup III} clusters, Mn preferentially occupies site 1, but some anomalous scattering from site 2 is observed, implying that both {sup 1}Mn{sup II}/{sup 2}Fe{sup II} and {sup 1}Fe{sup II}/{sup 2}Mn{sup II} complexes are competent to react with O{sub 2} to produce the corresponding oxidized states. However, with diminished Mn{sup II} loading in the reconstitution, there is no evidence for Mn occupancy of site 2, and the greater activity of these 'low-Mn' samples on a per-Mn basis implies that the {sup 1}Mn{sup IV}/{sup 2}Fe{sup III}-{beta} is at least the more active of the two oxidized forms and may be the only active form.« less

  12. Effects of low-level laser therapy on stem cells from human exfoliated deciduous teeth

    PubMed Central

    FERNANDES, Ana Paula; JUNQUEIRA, Marina de Azevedo; MARQUES, Nádia Carolina Teixeira; MACHADO, Maria Aparecida Andrade Moreira; SANTOS, Carlos Ferreira; OLIVEIRA, Thais Marchini; SAKAI, Vivien Thiemy

    2016-01-01

    ABSTRACT Low-Level Laser Therapy stimulates the proliferation of a variety of types of cells. However, very little is known about its effect on stem cells from human exfoliated deciduous teeth (SHED). Objective This study aimed to evaluate the influence of different laser therapy energy densities on SHED viability and proliferation. Material and Methods SHED were irradiated according to the groups: I (1.2 J/cm2 - 0.5 mW – 10 s), II (2.5 J/cm2 – 10 mW – 10 s), III (3.7 J/cm2 – 15 mW – 10 s), IV (5.0 J/cm2 – 20 mW – 10 s), V (6.2 J/cm2 – 25 mW – 10 s), and VI (not irradiated – control group). Cell viability was assessed 6 and 24 h after irradiation measuring the mitochondrial activity and using the Crystal Violet assay. Cell proliferation was assessed after 24, 48, and 72 h of irradiation by SRB assay. Results MTT assay demonstrated differences from 6 to 24 hours after irradiation. After 24 h, groups I and IV showed higher absorbance values than those of control group. Crystal Violet assay showed statistically differences in the absorbance rate from 6 to 24 h after irradiation for groups III and VI. At 24 h after irradiation, Group III absorbance rate was greater than that of groups I, II, and IV. Group VI absorbance rate was greater than that of groups I and IV. SRB assay showed that the group I had higher rates than those of groups II, III, V, and VI, at 24 h after irradiation. After 48 h, group I exhibited the greatest cell proliferation rate followed by groups III, V, and VI. After 72 h, group III exhibited the lowest cell proliferation rate than those of groups II, IV, and V. Conclusions The Low-Level Laser Therapy energy densities used in this study did not cause loss of cell viability and stimulated SHED proliferation within the parameters described in this study. PMID:27556203

  13. Clinical profile of patients with biopsy proven lupus nephritis at a tertiary care hospital from Northern Pakistan, 1995 to 2012.

    PubMed

    Ali, Akhtar; Mehmood, Anjum; Ali, Muhammad Usman

    2017-01-01

    TTo highlight the clinical spectrum of biopsy-proven lupus nephritis by analysing any variations in its histological subtypes across gender, varying age groups, serum creatinine levels and anti-double stranded deoxyribonucleic acid levels. This retrospective, observational study was conducted at the Lady Reading Hospital in collaboration with the Fauji Foundation Hospital, Peshawar, Pakistan, and comprised patient records of biopsy-proven lupus nephritis from 1995 to 2012. The cases were analysed according to clinical presentations and histological pattern of systemic lupus erythematosus nephritis. EpiData 3.1 and SPSS 17 were used for data analyses. Of the 2,000 renal biopsies performed, lupus nephritis was found in 74(3.7%) cases. Of them, 63(85.1%) were females and 11(14.9%) males. The mean age of the cases was 23.88±9.73 years (range: 10-55 years). Class IV lupus nephritis was seen in 38(51.4%) patients, followed by Class II in 15(20.3%), Class III in 10(13.5%), Class V and VI in 4(5.4%) each and Class I in 3(4.1%). Out of the combined Class III and IV cases, 25(52.08%) had serum creatinine levels of >1.2 mg/dL, whereas positive anti-double stranded deoxyribonucleic acid titers up to 50 IU/L were seen in all of the 48(100%) such patients. Overall, microscopic haematuria was found in 52(70.3%) cases, followed by arthralgia in 40(54.1%). Moreover, 32(50.8%) females and 6(54.5%) males had Type IV nephritis. Class VI lupus nephritis, in particular, were significantly more prominent in 31-40 years of age group when compared to other histological subtypes and age groups (p=0.0096, odds ratio: 23.25, 95% confidence interval: 2.15-251.21). Female predominance was observed in all histological sub-types of lupus nephritis. Class IV lupus was the most common histological pattern. Microscopic haematuria was the most common clinical presentation.

  14. IV INTERNATIONAL CONFERENCE ON ATOM AND MOLECULAR PULSED LASERS (AMPL'99): Efficient long-pulse XeCl laser with a prepulse formed by an inductive energy storage device

    NASA Astrophysics Data System (ADS)

    Baksht, E. Kh; Panchenko, Aleksei N.; Tarasenko, Viktor F.

    2000-06-01

    An efficient electric-discharge XeCl laser is developed, which is pumped by a self-sustained discharge with a prepulse formed by a generator with an inductive energy storage device and a semiconductor current interrupter on a basis of semiconductor opening switch (SOS) diodes. An output energy up to 800 mJ, a pulse length up to 450 ns, and a total laser efficiency of 2.2% were attained by using spark UV preionisation.

  15. Raman Shifted Nd:YAG Class I Eye-Safe Laser Development 21 January 1986

    NASA Astrophysics Data System (ADS)

    Nichols, R. W.; Ng, W. K.

    1986-07-01

    Hughes Aircraft has been developing a hand-held eye-safe laser rangefinder fo1r the Army utilizing Stimulated Raman Scattering technology. The device uses the 2915 cm-1 vibrational mode of methane (CH4) to wavelength shift the Nd:YAG pump laser's 1.064 micron to an eye-safe 1.543 micron. The result is a lightweight BRH Class I eye-safe tactical device. A brief description of Raman wavelength shifting basics is followed by description of the Hughes system.

  16. Simulation of dendritic growth reveals necessary and sufficient parameters to describe the shapes of dendritic trees

    NASA Astrophysics Data System (ADS)

    Trottier, Olivier; Ganguly, Sujoy; Bowne-Anderson, Hugo; Liang, Xin; Howard, Jonathon

    For the last 120 years, the development of neuronal shapes has been of great interest to the scientific community. Over the last 30 years, significant work has been done on the molecular processes responsible for dendritic development. In our ongoing research, we use the class IV sensory neurons of the Drosophila melanogaster larva as a model system to understand the growth of dendritic arbors. Our main goal is to elucidate the mechanisms that the neuron uses to determine the shape of its dendritic tree. We have observed the development of the class IV neuron's dendritic tree in the larval stage and have concluded that morphogenesis is defined by 3 distinct processes: 1) branch growth, 2) branching and 3) branch retraction. As the first step towards understanding dendritic growth, we have implemented these three processes in a computational model. Our simulations are able to reproduce the branch length distribution, number of branches and fractal dimension of the class IV neurons for a small range of parameters.

  17. A new class of relativistic stellar models

    NASA Astrophysics Data System (ADS)

    Haggag, Salah

    1995-03-01

    Einstein field equations for a static and spherically symmetric perfect fluid are considered. A formulation given by Patino and Rago is used to obtain a class of nine solutions, two of them are Tolman solutions I, IV and the remaining seven are new. The solutions are the correct ones corresponding to expressions derived by Patino and Rago which have been shown by Knutsen to be incorrect. Similar to Tolan solution IV each of the new solutions satisfies energy conditions inside a sphere in some range of two independent parameters. Besides, each solution could be matched to the exterior Schwarzschild solution at a boundary where the pressure vanishes and thus the solutions constitute a class of new physically reasonable stellar models.

  18. The effect of a class IV hurricane on emergency department operations.

    PubMed

    Sheppa, C M; Stevens, J; Philbrick, J T; Canada, M

    1993-09-01

    The objective of this study was to determine the impact on emergency department (ED) operations of Hurricane Hugo, a class IV hurricane that struck Charleston, South Carolina, on September 21, 1989. The study design was a retrospective record-based descriptive study and mail survey of the ED of a 300-bed regional medical center directly in the path of the storm. During the 3 weeks after the storm, ED patient volume increased 19% over that of the 3 weeks before the storm. Increased visit volumes were evident for at least 3 months. Compared with a similar period of the previous year, there was an increase in the proportion of patients seen for lacerations of all types, puncture wounds, stings, and falls. Sixty-two percent of physician offices were still closed 7 days after the storm. The direct effects of a class IV hurricane on ED operations included major alterations in the volume and types of patient visits. Because of the evacuation of approximately 40% of the coastal population and storm damage hindering travel, the increase in visit volume was less in magnitude but of longer duration has been reported in class III hurricanes.

  19. Laser-induced damage threshold tests of ultrafast multilayer dielectric coatings in various environmental conditions relevant for operation of ELI beamlines laser systems

    NASA Astrophysics Data System (ADS)

    Ďurák, Michal; Velpula, Praveen Kumar; Kramer, Daniel; Cupal, Josef; Medřík, Tomáš; Hřebíček, Jan; Golasowski, Jiří; Peceli, Davorin; Kozlová, Michaela; Rus, Bedřich

    2017-01-01

    Increasing the laser-induced damage resistance of optical components is one of the major challenges in the development of Peta-watt (PW) class laser systems. The extreme light infrastructure (ELI) beamlines project will provide ultrafast laser systems with peak powers up to 10 PW available every minute and PW class beams at 10 Hz complemented by a 5-TW, 1-kHz beamline. Sustainable performance of PW class laser systems relies on the durability of the employed optical components. As part of an effort to evaluate the damage resistance of components utilized in ELI beamlines systems, damage thresholds of several optical multilayer dielectric coatings were measured with different laser parameters and in different environments. Three coatings were tested with 10 Hz and 1 kHz pulse repetition rates, and the effect of a cleaning treatment on their damage resistance was examined. To explore the damage threshold behavior at different vacuum levels, one coating was subject to tests at various residual gas pressures. No change of damage threshold in a high vacuum with respect to ambient pressure was recorded. The effect of the cleaning treatment was found to be inconsistent, suggesting that development of the optimal cleaning treatment for a given coating requires consideration of its specific properties.

  20. High energy laser demonstrators for defense applications

    NASA Astrophysics Data System (ADS)

    Jung, M.; Riesbeck, Th.; Schmitz, J.; Baumgärtel, Th.; Ludewigt, K.; Graf, A.

    2017-01-01

    Rheinmetall Waffe Munition has worked since 30 years in the area of High Energy Laser (HEL) for defence applications, starting from pulsed CO2 to pulsed glass rods lasers. In the last decade Rheinmetall Waffe Munition changed to diode pumped solid state laser (DPSSL) technology and has successfully developed, realised and tested a variety of versatile HEL weapon demonstrators for air- and ground defence scenarios like countering rocket, artillery, mortar, missile (RAMM), unmanned aerial systems (UAS) and unexploded ordnances clearing. By employing beam superimposing technology and a modular laser weapon concept, the total optical power has been successively increased. Stationary weapon platforms, military vehicles and naval platforms have been equipped with high energy laser effectors. The contribution gives a summary of the most recent development stages of Rheinmetalls HEL weapon program. In addition to the stationary 30 kW laser weapon demonstrator, we present vehicle based HEL demonstrators: the 5 kW class Mobile HEL Effector Track V, the 20 kW class Mobile HEL Effector Wheel XX and the 50 kW class Mobile HEL Effector Container L and the latest 10 kW HEL effector integrated in the naval weapon platform MLG 27. We describe the capabilities of these demonstrators against different potential targets. Furthermore, we will show the capability of the 30 kW stationary Laser Weapon Demonstrator integrated into an existing ground based air defence system to defeat saturated attacks of RAMM and UAS targets.

  1. Predictors of Operative Mortality for Coronary Bypass Grafting in Patients with Ischemic Heart Disease

    PubMed Central

    Langou, Rene A.; Wiles, John C.; Peduzzi, Peter N.; Hammond, Graeme; Cohen, Lawrence S.

    1978-01-01

    Predictors for operative mortality (OM) were studied in 172 consecutive patients (pts) undergoing coronary artery grafts (CAG) for angina pectoris. Seventy eight pts had Class IV angina; of the 147 patients given propranolol, 41 were gradually withdrawn from propranolol and finally discontinued 24 hours before surgery, and 106 were abruptly withdrawn from propranolol 24 hours before CAG; 20 pts had left main coronary disease; 156 pts had cardiopulmonary bypass (CPB) time shorter than 20 minutes, and 16 pts had a CPB longer than 120 minutes. The operative mortality was 5.2% (9/172) for the entire group. Class IV angina (OM 7%), abrupt propranolol withdrawal (OM 6.6%), left main coronary artery disease (OM 25%), and CPB longer than 120 minutes (OM 50%), all significantly increased OM. These variables were interdependent, however, as many pts belonged to several predictor categories, combinations of predictors were examined, in order to more accurately predict the risk of individual pts. The combination of left main coronary artery disease and CPB longer than 120 minutes; and Class IV angina and CPB longer than 120 minutes were significantly associated with higher operative mortality. We conclude that Class IV angina, abrupt propranolol withdrawal, left main coronary artery disease and prolonged CPB are potent, interdependent predictors of OM in pts undergoing CAG. Consideration of these predictors, alone and in combination, allows effective prediction of OM for CAG in patients with stable angina pectoris. PMID:307873

  2. Biomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects

    PubMed Central

    Akay, Canan; Yaluğ, Suat

    2015-01-01

    Background The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). Material\\Methods A 3-dimensional finite element model of an Aramany class IV defect was created. Three different implant-retained obturator prostheses were modeled: model 1 with 1 zygomatic implant and 1 dental implant, model 2 with 1 zygomatic implant and 2 dental implants, and model 3 with 2 zygomatic implants. Locator attachments were used as a superstructure. A 150-N load was applied 3 different ways. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis are expressed in MPa. Results In all loading conditions, model 3 (when compared models 1 and 2) showed the lowest maximum principal stress value. Model 3 is the most appropirate reconstruction in Aramany class IV maxillary defects. Two zygomatic implants can reduce the stresses in model 3. The distribution of stresses on prostheses were more rational with the help of zygoma implants, which can distribute the stresses on each part of the maxilla. Conclusions Aramany class IV obturator prosthesis placement of 2 zygomatic implants in each side of the maxilla is more advantageous than placement of dental implants. In the non-defective side, increasing the number of dental implants is not as suitable as zygomatic implants. PMID:25714086

  3. Experimental Investigation for 100-Joule-class TEA CO2 Laser and Gas Interaction

    NASA Astrophysics Data System (ADS)

    Dou, Zhiguo; Yao, Honglin; Wang, Jun; Wen, Ming; Wang, Peng; Yang, Jan; Li, Chong

    2006-05-01

    Impulse coupling coefficient Cm is one of the most important performance parameters in laser propulsion. Cm is the impulse increment of lightcraft that per joule laser beam energy acts on. The TEA CO2 laser, whose single pulse energy is 100-Joule-class and wavelength is 10.6μm, is adopted by experimental research. In experimental environment cabin, the parabolic lightcraft is fixed on impact pendulum. Using Air, N2, He, CO2, N2-He and N2-CO2, different Cm is obtained. Experimental results indicate that Cm of the mixed gas is improved through changing gas component ratio.

  4. Laser-induced damage of intrinsic and extrinsic defects by picosecond pulses on multilayer dielectric coatings for petawatt-class lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Negres, Raluca A.; Carr, Christopher W.; Laurence, Ted A.

    2016-08-01

    Here, we describe a damage testing system and its use in investigating laser-induced optical damage initiated by both intrinsic and extrinsic precursors on multilayer dielectric coatings suitable for use in high-energy, large-aperture petawatt-class lasers. We employ small-area damage test methodologies to evaluate the intrinsic damage resistance of various coatings as a function of deposition methods and coating materials under simulated use conditions. In addition, we demonstrate that damage initiation by raster scanning at lower fluences and growth threshold testing are required to probe the density of extrinsic defects, which will limit large-aperture optics performance.

  5. Mobile and stationary laser weapon demonstrators of Rheinmetall Waffe Munition

    NASA Astrophysics Data System (ADS)

    Ludewigt, K.; Riesbeck, Th.; Baumgärtel, Th.; Schmitz, J.; Graf, A.; Jung, M.

    2014-10-01

    For some years Rheinmetall Waffe Munition has successfully developed, realised and tested a variety of versatile high energy laser (HEL) weapon systems for air- and ground-defence scenarios like C-RAM, UXO clearing. By employing beam superimposition technology and a modular laser weapon concept, the total optical power has been successively increased. Stationary weapon platforms and now military mobile vehicles were equipped with high energy laser effectors. Our contribution summarises the most recent development stages of Rheinmetalls high energy laser weapon program. We present three different vehicle based HEL demonstrators: the 5 kW class Mobile HEL Effector Track V integrated in an M113 tank, the 20 kW class Mobile HEL Effector Wheel XX integrated in a multirole armoured vehicle GTK Boxer 8x8 and the 50 kW class Mobile HEL Effector Container L integrated in a reinforced container carried by an 8x8 truck. As a highlight, a stationary 30 kW Laser Weapon Demonstrator shows the capability to defeat saturated attacks of RAM targets and unmanned aerial vehicles. 2013 all HEL demonstrators were tested in a firing campaign at the Rheinmetall testing centre in Switzerland. Major results of these tests are presented.

  6. Modulation of type I immediate and type IV delayed immunoreactivity using direct suggestion and guided imagery during hypnosis.

    PubMed

    Zachariae, R; Bjerring, P; Arendt-Nielsen, L

    1989-11-01

    Cutaneous reactivity against histamine skin prick test (Type I) and purified tuberculin protein derivative (Mantoux reaction, Type IV) was studied in eight volunteers under hypnosis. Types I and IV immunoreactivity were modulated by direct suggestion (Type I) and guided imagery (Type IV). The volunteers were highly susceptible subjects, selected by means of the Harvard Group Scale of Hypnotic Susceptibility, Form A. When the volunteers underwent hypnotic suggestion to decrease the cutaneous reaction to histamine prick test, a significant (P less than 0.02) reduction of the flare reaction (area of erythema) was observed compared with control histamine skin prick tests. The wheal reaction did not respond to hypnotic suggestion. Neither wheal nor flare reaction could be increased in size by hypnotic suggestion compared with control histamine skin prick tests. A hypnotic suggestion of increasing the Type IV reaction on one arm and decreasing the reaction on the other revealed a significant difference in both erythema size (P less than 0.02) and palpable induration (P less than 0.01). In two cases the reactions were monitored by laser doppler blood flowmetry and skin thickness measurement by ultrasound. The difference between the suggested increased and decreased reaction was 19% for the laser doppler bloodflow (in favor of the augmented side), and 44% for the dermal infiltrate thickness. This study objectively supports the numerous uncontrolled case reports of modulation of immunoreactivity in allergic diseases involving both Type I and Type IV skin reactions following hypnotic suggestions.

  7. Framing of Transitional Pedagogic Practices in the Sciences: Enabling Access

    ERIC Educational Resources Information Center

    Ellery, Karen

    2017-01-01

    Educational literature shows that students from working-class backgrounds are significantly less likely to persist to completion in higher education than middle-class students. This paper draws theoretically and analytically on Bernstein's ([1990. "Class, Codes and Control, Volume IV: The Structuring of Pedagogic Discourse." London:…

  8. Multiple minimally invasive Erbium:YAG laser mini-peels for skin rejuvenation: An objective assessment

    PubMed Central

    El-Domyati, Moetaz; El-Ammawi, Tarek S.; Medhat, Walid; Moawad, Osama; Mahoney, Mỹ G.; Uitto, Jouni

    2012-01-01

    Summary Background As the demand for minimally invasive rejuvenation is increasing, micro-peel resurfacing using Erbium:Yttrium Aluminium Garnet (Er:YAG ) laser 2940 nm has been reported for the treatment of photoaged skin without ablation of the epidermis. However, little is known about the efficacy and underlying histologic changes associated with this type of treatment. Aims The purpose of this study is to evaluate the clinical effect and objectively quantify the histological changes in response to multiple sessions of Er:YAG laser 2940 nm mini-peels. Patients and methods Six female volunteers of Fitzpatrick skin type III-IV and Glogau’s class I-III wrinkles were subjected to six microresurfacing peels at 2-week intervals using Er:YAG 2940 nm laser at sub-ablative fluences of 2 - 3 J/cm2 to treat periorbital rhytides. Quantitative evaluation of collagen types I, III and VII, newly synthesized collagen, total elastin and tropoelastin was performed by histochemistry and immunohistochemistry coupled with computerized morphometric analysis at base line, end of treatment, and three months post treatment. Results Compared to the base line, evaluation of volunteers revealed obvious clinical improvement in response to Er:YAG mini-peels. Collagen types I, III, and VII, as well as newly synthesized collagen, together with tropoelastin showed a statistically significant increase in response to treatment, while the mean level of total elastin was significantly decreased in response to treatment. However, this was followed by regression of improvement at 3 months post treatment, but was still better than baseline. Conclusions The present study revealed that multiple Er:YAG mini-peels is a promising treatment option for photoaging as it reverses the signs of photoaged skin with little downtime and side effects. However, to maintain the short term improvement achieved after treatment, continued Er:YAG 2940 nm laser mini-peels is required. PMID:22672276

  9. Bibliography of Soviet Laser Developments, Number 67, September-October 1983.

    DTIC Science & Technology

    1984-12-05

    5 g. Pb(l-x)Sn(x)Te .................. 5 iv V.--",7 4. Glass a. Mdscellaneous.................... 6- c., Er...the threshold current in injection lasers based on Pbl-xSnxTe semiconductors. FTPPA, no. 9v 1983, 1631-1634. 4. Glass a. Miscellaneous b. Nd 45...Shcherbakov, A.A.; Mak, A.A.; Sklizkov, G.V. (FIAN). Limit efficiency of neodymium glass lasers. KRSFA, no. 9, 1983, 8-12. c . Er 46. Lunter, S.G.; Murzin

  10. Analysis of class II (hydrolytic) and class I (beta-lyase) apurinic/apyrimidinic endonucleases with a synthetic DNA substrate.

    PubMed Central

    Levin, J D; Demple, B

    1990-01-01

    We have developed simple and sensitive assays that distinguish the main classes of apurinic/apyrimidinic (AP) endonucleases: Class I enzymes that cleave on the 3' side of AP sites by beta-elimination, and Class II enzymes that cleave by hydrolysis on the 5' side. The distinction of the two types depends on the use of a synthetic DNA polymer that contains AP sites with 5'-[32P]phosphate residues. Using this approach, we now show directly that Escherichia coli endonuclease IV and human AP endonuclease are Class II enzymes, as inferred previously on the basis of indirect assays. The assay method does not exhibit significant interference by nonspecific nucleases or primary amines, which allows the ready determination of different AP endonuclease activities in crude cell extracts. In this way, we show that virtually all of the Class II AP endonuclease activity in E. coli can be accounted for by two enzymes: exonuclease III and endonuclease IV. In the yeast Saccharomyces cerevisiae, the Class II AP endonuclease activity is totally dependent on a single enzyme, the Apn1 protein, but there are probably multiple Class I enzymes. The versatility and ease of our approach should be useful for characterizing this important class of DNA repair enzymes in diverse systems. PMID:1698278

  11. How the Change in IBS Criteria From Rome III to Rome IV Impacts on Clinical Characteristics and Key Pathophysiological Factors.

    PubMed

    Aziz, Imran; Törnblom, Hans; Palsson, Olafur S; Whitehead, William E; Simrén, Magnus

    2018-06-08

    The diagnostic criteria for irritable bowel syndrome (IBS) have recently been updated from Rome III to Rome IV. Whereas in Rome III a diagnosis of IBS entailed chronic abdominal pain or discomfort at least 3 days per month, in Rome IV the term discomfort has been removed and the frequency of abdominal pain increased to at least 1 day per week. We examined how this change in IBS criteria impacts on clinical characteristics and pathophysiological factors. A total of 542 Swedish subjects with Rome III IBS completed a baseline questionnaire enquiring for the number of abdominal pain days in the last 10 days; this was subsequently used as a surrogate marker to identify Rome IV IBS, in that (a) those with 0 or 1 day of pain were classed as Rome IV-negative, and (b) those with ≥2 days of pain were classed as Rome IV-positive. Comparisons were made between Rome IV-positive and -negative IBS groups for demographics, IBS subtype, gastrointestinal and psychological symptoms, somatisation, fatigue, disease-specific quality of life, rectal sensitivity, and oro-anal transit time. Overall, 85% of Rome III IBS patients fulfilled the Rome IV criteria for IBS, but 15% did not. Rome IV-positive subjects were significantly more likely to be female, have poorer quality of life, greater pain severity, bloating, somatisation, fatigue, and rectal sensitivity than Rome IV-negative subjects. There were no differences in severity of anxiety or depression, IBS subtypes, bowel habit dissatisfaction, or oro-anal transit time. Finally, increasing number of pain days correlated positively with symptoms and visceral hypersensitivity. Most Rome III-positive IBS patients seeking healthcare fulfil the Rome IV IBS criteria. They constitute a more severe group than those who lose their IBS diagnosis.

  12. Optical Characterization of IV-VI Mid-Infrared VCSEL

    DTIC Science & Technology

    2002-01-01

    vertical cavity surface emitting laser ( VCSEL ). A power...il quantum well (QW) devices [5], there has little progress until recently in developing mid-IR vertical cavity surface emitting laser ( VCSEL ). This...structures and PbSrSe thin films were grown on Bat; (111) substrates by molecular beam epitaxy ( MBE ) and characterized by Fourier transform infi-ared

  13. Pulsed laser deposited hexagonal wurzite ZnO thin-film nanostructures/nanotextures for nanophotonics applications

    NASA Astrophysics Data System (ADS)

    John Chelliah, Cyril Robinson Azariah; Swaminathan, Rajesh

    2018-01-01

    The high-quality and transparent thin-film zinc oxide (ZnO) nanostructures/nanotextures deposited on glass and silicon substrates using pulsed laser deposition (PLD) technique are reported. A solid-state, Nd-YAG laser was used for the PLD process. The films were deposited (i) at room temperature of 25°C (as deposited), (ii) at 150°C, (iii) at 300°C, (iv) at 450°C, and (v) at 600°C and annealed in the vacuum chamber. The depositions were also carried out at different laser repetition rates such as 10 and 5 Hz. UV spectroscopy and photoluminescence (PL) spectroscopy were carried out for optical studies. X-ray diffraction studies were carried out for all samples and analyzed the effects of the laser repetition rate, deposition, and annealing temperatures on the structural properties. Field-emission scanning electron microscope images are recorded for the best-structured samples. The electrical parameters were calibrated using the Hall effect measurement system and the IV characterization was performed using a CHI Electrochemical workstation. The deposition temperature has a significant effect on the microstrain and dislocation density of the ZnO thin film and optical phenomena with various electrical parameters, including the electron mobility, conductivity, and magnetoresistance. These promising results are suitable conditions for nanophotonics applications.

  14. Clinical Outcomes and Complications Associated with Fractional Lasers: A Review of 730 Patients.

    PubMed

    Cohen, Steven R; Goodacre, Ashley; Lim, Soobin; Johnston, Jennifer; Henssler, Cory; Jeffers, Brian; Saad, Ahmad; Leong, Tracy

    2017-02-01

    Fractional lasers were introduced to provide increased safety, while maintaining high efficacy and patient satisfaction. Patients with virtually all Fitzpatrick skin types could be safely treated using a wide spectrum of wavelengths and a broad array of skin conditions, and aging could be addressed. Although safety studies have been reported for ablative CO 2 and erbium lasers, surprisingly few data are available on adverse events and complications associated with fractional lasers. We report the frequency of adverse events, skin improvement and complications in a broad range of skin types using a standardized protocol that can be safely tailored to the patient's presenting complaints by varying the laser wavelength and number of treatments. The medical records of 730 patients (>90% females, age ranged from 50.5. to 59.9 years.) who had been treated at FACES+ Aesthetic Facility were reviewed. Patients were followed from 1 to 10 months and were reviewed to determine the frequency of complications, as well as their frequency, type, cause, treatment and resolution thereof. Patients were categorized by Fitzpatrick skin type (I-IV) to determine whether skin type was related to the frequency of complications. Improvement in skin condition (wrinkles, nasolabial folds and pigment) was rated by a technician before and after treatment using a Likert scale, 0-5, with 0 being no change and 5 being the most improvement. Seven hundred thirty patients underwent procedures using fractional lasers in our center. Procedures were carried out with 3 different laser wavelengths, depending on the condition(s) treated (wrinkling vs. pigmentation issues, etc.) and the patients' desired length of downtime. The fractional Fraxel 1927-nm laser was used in 224 patients [Fitzpatrick skin type I (2.2%), II (38.4%), III (46.0%), IV (12.5%)]; the fractional Fraxel 1550-nm laser was used in 334 [type I (4.5%), II (31.9%), III (50.0%), IV (13.3%)], and the fractional Fraxel CO 2 laser was used in 172 [type 1 (4.7%), II (49.7%), III (41.5%), IV (4.1%)]. The Fraxel CO 2 laser showed greater improvement in wrinkles and naso-labial fold (p < 0.001). The greatest improvement in pigmentation was seen with the Fraxel 1927-nm laser (p < 0.001). Adverse events and complications occurred in 31 of 730 patients (4.2%). There was no significant difference in the rate of complications among the three treatments (p = 0.26). Complications were generally minor, and all resolved completely with treatment. Complications occurred in 4.0% of patients having the fractional Fraxel 1927-nm laser, 3.3% of patients having the fractional Fraxel 1550 nm and 6.4% of patients having the fractional Fraxel CO 2 laser. Complications included 5 herpes simplex virus breakouts, 13 acne eruptions, 1 abrasion, 1 bacterial infection, 9 dermatitis, 1 drug eruption, 4 prolonged erythema, 1 hyperpigmentation, 1 increased swelling and 1 telangiectasia. There was no significant relationship between Fitzpatrick skin type and incidence of complications (p = 0.37). Fractional lasers in general have reduced complication rates, while maintaining high degrees of patient satisfaction. Since their inception in early 2004, our clinic has utilized fractional lasers to treat patients from a variety of ethnic backgrounds and diverse skin types with an overall complication rate of 4.2%, all of which resolved. Comprehensive care of patients with facial aging is not limited to surgery alone and should include these types of strategies to appropriately and safely address photo-damage and photo-aging. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  15. Psychosocial stressors and the prognosis of major depression: a test of Axis IV

    PubMed Central

    Gilman, Stephen E.; Trinh, Nhi-Ha; Smoller, Jordan W.; Fava, Maurizio; Murphy, Jane M.; Breslau, Joshua

    2013-01-01

    Background Axis IV is for reporting “psychosocial and environmental problems that may affect the diagnosis, treatment, and prognosis of mental disorders.” No studies have examined the prognostic value of Axis IV in DSM-IV. Method We analyzed data from 2,497 participants in the National Epidemiologic Survey on Alcohol and Related Conditions with major depressive episode (MDE). We hypothesized that psychosocial stressors predict a poor prognosis of MDE. Secondarily, we hypothesized that psychosocial stressors predict a poor prognosis of anxiety and substance use disorders. Stressors were defined according to DSM-IV’s taxonomy, and empirically using latent class analysis. Results Primary support group problems, occupational problems, and childhood adversity increased the risks of depressive episodes and suicidal ideation by 20–30%. Associations of the empirically derived classes of stressors with depression were larger in magnitude. Economic stressors conferred a 1.5-fold increase in risk for a depressive episode (CI=1.2–1.9); financial and interpersonal instability conferred a 1.3-fold increased risk of recurrent depression (CI=1.1–1.6). These two classes of stressors also predicted the recurrence of anxiety and substance use disorders. Stressors were not related to suicidal ideation independent from depression severity. Conclusions Psychosocial and environmental problems are associated with the prognosis of MDE and other Axis I disorders. Though DSM-IV’s taxonomy of stressors stands to be improved, these results provide empirical support for the prognostic value of Axis IV. Future work is needed to determine the reliability of Axis IV assessments in clinical practice, and the usefulness of this information to improving the clinical course of mental disorders. PMID:22640506

  16. Laser Safety: A Laser Alignment Practical Training Course

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woods, Michael; Edstrom, Steve; /SLAC

    2011-01-26

    SLAC National Accelerator Laboratory has developed a Laser Alignment Practical Training Course as one of its core laser safety classes. The course is taught to small groups of up to three students and takes 1-3 hours to complete. This practical course is not a substitute for site-specific On-the-Job Training; it does, however, provide a good introduction in core laser safety practices that can be broadly applied. Alignment and diagnostic tasks are performed with low power lasers. Students learn safe alignment and diagnostic techniques and how to avoid common mistakes that might lead to an accident. The class is taught bymore » laser supervisors, enabling them to assess the skill level of new laser personnel and determine the subsequent level of supervision needed. The course has six alignment tasks. For each task, discussion points are given for the instructor to review with the students. The optics setup includes different wavelength lasers, a beam expander, mirrors, irises, a periscope, a beam-splitting polarizer and a diffraction grating. Diagnostic tools include viewing cards, an IR viewer and a ccd camera. Laser eyewear is available to block some laser wavelengths in the setup.« less

  17. Damage modeling and statistical analysis of optics damage performance in MJ-class laser systems.

    PubMed

    Liao, Zhi M; Raymond, B; Gaylord, J; Fallejo, R; Bude, J; Wegner, P

    2014-11-17

    Modeling the lifetime of a fused silica optic is described for a multiple beam, MJ-class laser system. This entails combining optic processing data along with laser shot data to account for complete history of optic processing and shot exposure. Integrating with online inspection data allows for the construction of a performance metric to describe how an optic performs with respect to the model. This methodology helps to validate the damage model as well as allows strategic planning and identifying potential hidden parameters that are affecting the optic's performance.

  18. Effect of CO2 laser on Class V cavities of human molar teeth under a scanning electron microscope.

    PubMed

    Watanabe, I; Lopes, R A; Brugnera, A; Katayama, A Y; Gardini, A E

    1996-01-01

    The purpose of this study was to evaluate the effects of CO2 laser on dentin of class V cavities of extracted human molar teeth using a scanning electron microscope. SEM showed a smooth area with concentric lines formed by melting with subsequent recrystallization of dentin, areas of granulation, vitrified surface, numerous cracks, and irregular areas of descamative dentin. These data indicate that CO2 laser (4 and 6 watts) produces dentin alterations and limit its clinical applications.

  19. Bibliography of Soviet Laser Developments, Number 88, March - April 1987.

    DTIC Science & Technology

    1988-03-03

    IPG. Trudy, no. 67, 1986, 123-128. 67 560. Kublashvili, G.S. ). Laser probe measurement of sea wave parameters near shore. SAKNA, vol. 125, no. 3, 1987...RZFZA, 87/4L838). 562. Lezhen, A.S.; Sviridov, S.A.; Stemkovskiy, A.I. (IOAN; SimGU). Method and device to determine rises and gradients of the sea ...podstilayushchey poverkhnosti. IOA. Novosibirsk, Nauka, 1987, 223-239. 573. Shevchenko, T.B.; Shugan, I.V. 0. Laser probing of the sea surface from aircraft

  20. IV INTERNATIONAL CONFERENCE ON ATOM AND MOLECULAR PULSED LASERS (AMPL'99): Critical electron density in a self-contained copper vapour laser in the restricted pulse repetition rate

    NASA Astrophysics Data System (ADS)

    Yakovlenko, Sergei I.

    2000-06-01

    One of the mechanisms of the inversion breaking in copper vapour lasers caused by a high prepulse electron density is considered. Inversion breaking occurs at a critical electron density Ne cr. If the prepulse electron density exceeds Ne cr, the electron temperature Te cr cannot reach, during a plasma heating pulse, the temperature of ~2eV required for lasing. A simple estimate of Ne cr is made.

  1. Investigation of the Low Power Stage of an 1178 nm Raman System

    DTIC Science & Technology

    2013-12-23

    LEANNE HENRY, DR-III, DAF KENTON T. WOOD, DR-IV, DAF Work Unit Manager Chief, Laser Division This report is published in the...and 1069 nm pumped Raman laser system where the second Stokes is amplified in a 1121 nm resonator defined by high reflector fiber Bragg gratings (FBGs...the gratings was found to impact the performance of the laser and needs to be dealt with in order to obtain high 1178 nm output power levels. In order

  2. Changes in the social class gradient of cirrhosis mortality in England and Wales across the 20th century.

    PubMed

    Crombie, Iain K; Precious, Elaine

    2011-01-01

    To explore the nature of the social class gradient of cirrhosis mortality in England and Wales across the 20th century. Data on male cirrhosis mortality by social class were obtained from the Registrar General's Decennial Supplements for the years 1921-1991. Data for 1941 were not collected because of the second World War. In 1921, cirrhosis mortality was substantially higher among the professional and managerial classes (I and II) than among the other social classes (III-V). This marked social class difference persisted until 1961 when the differences between the social classes were inconsistent. By 1991, the gradient had reversed and the lower social classes (IV and V) had the higher mortality. The excess mortality was greatest for social class V. The change in the mortality gradient is stark: in 1921social classes I and II had a cirrhosis mortality at least twice that of social classes IV and V, but by 1991 this ratio had reversed. The reversal in the social class gradient of cirrhosis mortality indicates a major change in risk factor distribution across social classes. Differential changes in alcohol consumption are a possible explanation for this change, although the 1991 social class gradient in cirrhosis is inconsistent with alcohol consumption data from national surveys. Further research is required to clarify the explanation for the observed gradient, so that appropriate preventive measures can be put into place.

  3. 40 CFR 144.26 - Inventory requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... “Inventory of Injection Wells,” OMB No. 158-R0170. (b) Additional contents. For EPA administered programs...) Class II enhanced recovery wells; (ii) Class IV wells; (iii) The following Class V wells: (A) Sand or... (40 CFR 146.5 (e)(11)) (C) Geothermal energy recovery wells [§ 146.5(e)(12)]; (D) Brine return flow...

  4. Strong-field physics with mid-infrared lasers

    NASA Astrophysics Data System (ADS)

    Pogorelsky, I. V.

    2002-04-01

    Mid-infrared gas laser technology promises to become a unique tool for research in strong-field relativistic physics. The degree to which physics is relativistic is determined by a ponderomotive potential. At a given intensity, a 10 μm wavelength CO2 laser reaches a 100 times higher ponderomotive potential than the 1 μm wavelength solid state lasers. Thus, we can expect a proportional increase in the throughput of such processes as laser acceleration, x-ray production, etc. These arguments have been confirmed in proof-of-principle Thomson scattering and laser acceleration experiments conducted at BNL and UCLA where the first terawatt-class CO2 lasers are in operation. Further more, proposals for the 100 TW, 100 fs CO2 lasers based on frequency-chirped pulse amplification have been conceived. Such lasers can produce physical effects equivalent to a hypothetical multi-petawatt solid state laser. Ultra-fast mid-infrared lasers will open new routes to the next generation electron and ion accelerators, ultra-bright monochromatic femtosecond x-ray and gamma sources, allow to attempt the study of Hawking-Unruh radiation, and explore relativistic aspects of laser-matter interactions. We review the present status and experiments with terawatt-class CO2 lasers, sub-petawatt projects, and prospective applications in strong-field science. .

  5. Comparative hazard evaluation of near-infrared diode lasers.

    PubMed

    Marshall, W J

    1994-05-01

    Hazard evaluation methods from various laser protection standards differ when applied to extended-source, near-infrared lasers. By way of example, various hazard analyses are applied to laser training systems, which incorporate diode lasers, specifically those that assist in training military or law enforcement personnel in the proper use of weapons by simulating actual firing by the substitution of a beam of near-infrared energy for bullets. A correct hazard evaluation of these lasers is necessary since simulators are designed to be directed toward personnel during normal use. The differences among laser standards are most apparent when determining the hazard class of a laser. Hazard classification is based on a comparison of the potential exposures with the maximum permissible exposures in the 1986 and 1993 versions of the American National Standard for the Safe Use of Lasers, Z136.1, and the accessible emission limits of the federal laser product performance standard. Necessary safety design features of a particular system depend on the hazard class. The ANSI Z136.1-1993 standard provides a simpler and more accurate hazard assessment of low-power, near-infrared, diode laser systems than the 1986 ANSI standard. Although a specific system is evaluated, the techniques described can be readily applied to other near-infrared lasers or laser training systems.

  6. STRONG FIELD PHYSICS WITH MID INFRARED LASERS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    POGORELSKY,I.V.

    2001-08-27

    Mid-infrared gas laser technology promises to become a unique tool for research in strong-field relativistic physics. The degree to which physics is relativistic is determined by a ponderomotive potential. At a given intensity, a 10 {micro}m wavelength CO{sub 2} laser reaches a 100 times higher ponderomotive potential than the 1 {micro}m wavelength solid state lasers. Thus, we can expect a proportional increase in the throughput of such processes as laser acceleration, x-ray production, etc. These arguments have been confirmed in proof-of-principle Thomson scattering and laser acceleration experiments conducted at BNL and UCLA where the first terawatt-class CO{sub 2} lasers aremore » in operation. Further more, proposals for the 100 TW, 100 fs CO{sub 2} lasers based on frequency-chirped pulse amplification have been conceived. Such lasers can produce physical effects equivalent to a hypothetical multi-petawatt solid state laser. Ultra-fast mid-infrared lasers will open new routes to the next generation electron and ion accelerators, ultra-bright monochromatic femtosecond x-ray and gamma sources, allow to attempt the study of Hawking-Unruh radiation, and explore relativistic aspects of laser-matter interactions. We review the present status and experiments with terawatt-class CO{sub 2} lasers, sub-petawatt projects, and prospective applications in strong-field science.« less

  7. kW-class diode laser bars

    NASA Astrophysics Data System (ADS)

    Strohmaier, S. G.; Erbert, G.; Meissner-Schenk, A. H.; Lommel, M.; Schmidt, B.; Kaul, T.; Karow, M.; Crump, P.

    2017-02-01

    Progress will be presented on ongoing research into the development of ultra-high power and efficiency bars achieving significantly higher output power, conversion efficiency and brightness than currently commercially available. We combine advanced InAlGaAs/GaAs-based epitaxial structures and novel lateral designs, new materials and superior cooling architectures to enable improved performance. Specifically, we present progress in kilowatt-class 10-mm diode laser bars, where recent studies have demonstrated 880 W continuous wave output power from a 10 mm x 4 mm laser diode bar at 850 A of electrical current and 15°C water temperature. This laser achieves < 60% electro-optical efficiency at 880 W CW output power.

  8. Intravenous Solutions for Exploration Missions

    NASA Technical Reports Server (NTRS)

    Miller, Fletcher J.; Niederhaus, Charles; Barlow, Karen; Griffin, DeVon

    2007-01-01

    This paper describes the intravenous (IV) fluids requirements being developed for medical care during NASA s future exploration class missions. Previous research on IV solution generation and mixing in space is summarized. The current exploration baseline mission profiles are introduced, potential medical conditions described and evaluated for fluidic needs, and operational issues assessed. We briefly introduce potential methods for generating IV fluids in microgravity. Conclusions on the recommended fluid volume requirements are presented.

  9. ADHD latent class clusters: DSM-IV subtypes and comorbidity

    PubMed Central

    Elia, Josephine; Arcos-Burgos, Mauricio; Bolton, Kelly L.; Ambrosini, Paul J.; Berrettini, Wade; Muenke, Maximilian

    2014-01-01

    ADHD (Attention Deficit Hyperactivity Disorder) has a complex, heterogeneous phenotype only partially captured by Diagnostic and Statistical Manual of Mental Disorders (DSM-IV) criteria. In this report, latent class analyses (LCA) are used to identify ADHD phenotypes using K-SADS-IVR (Schedule for Affective Disorders & Schizophrenia for School Age Children-IV-Revised) symptoms and symptom severity data from a clinical sample of 500 ADHD subjects, ages 6–18, participating in an ADHD genetic study. Results show that LCA identified six separate ADHD clusters, some corresponding to specific DSM-IV subtypes while others included several subtypes. DSM-IV comorbid anxiety and mood disorders were generally similar across all clusters, and subjects without comorbidity did not aggregate within any one cluster. Age and gender composition also varied. These results support findings from population-based LCA studies. The six clusters provide additional homogenous groups that can be used to define ADHD phenotypes in genetic association studies. The limited age ranges aggregating in the different clusters may prove to be a particular advantage in genetic studies where candidate gene expression may vary during developmental phases. DSM-IV comorbid mood and anxiety disorders also do not appear to increase cluster heterogeneity; however, longitudinal studies that cover period of risk are needed to support this finding. PMID:19900717

  10. Ho:YAG laser arthroscopy of the knee

    NASA Astrophysics Data System (ADS)

    Sisto, Domenick J.; Blazina, Martin E.; Hirsh, Linda C.

    1994-09-01

    The HO:YAG laser is a near-contact laser with a capacity to ablate or cut tissues. The ablation function allows the surgeon to remove meniscal tissue, lyse and resect adhesions, melt loose bodies, and dissolve inflamed synovium. The cutting function of the laser is utilized to perform a lateral release or resect torn menisci. The laser can also be utilized to drill holes in Grade IV chondromalacic lesions to initiate a healing response. The laser has been embraced by orthopaedic surgeons because of its shape and versatility. The tip is only 2 mm wide and can be delivered into the tight posterior compartments of the knee with no damaging contact with the articular surfaces. The laser coagulates as it works and bleeding is minimized. The laser can function both as a cutting and ablating tool. The laser can also drill holes into subchondral bone to, hopefully, initiate a healing response.

  11. The "index cutback technique": a three-dimensional guided layering approach in direct class IV composite restorations.

    PubMed

    Ammannato, Riccardo; Ferraris, Federico; Allegri, Mario

    One of the main difficulties encountered with conventional class IV direct composite restorations is the layering management in terms of three-dimensionality and shape control. The major concern is the predictability of the esthetic outcome, which is closely linked to the clinician's skills. This article presents a predictable approach to treat class IV direct composite restorations. The technique allows for the shape and thickness of different composite layers to be guided through transparent indexes that have been carried out previously on a planned wax-up. The final goal is to achieve a good esthetic outcome in an easy and fast way through a copy-and-paste approach. The "index cutback technique" is a complementary variant of the "index technique" for class IV direct restorations. After the casts have been generated, the technician creates a full wax-up of the tooth to be restored. A transparent silicone key of the full wax-up provides the full enamel index that is then cut with a blade along the incisal edge to achieve two enamel indexes, one palatal and one buccal. Then, the required amount of wax is removed from the full wax-up through a cutback step. The aim of this step is to remove a suitable amount of wax to leave a predetermined space for the composite enamel layers, both on the palatal and buccal surfaces. A second transparent silicone key is built on the cutback wax-up to achieve the cutback dentin index, which is then used to press the composite dentin onto the prepared tooth.

  12. Magnetic resonance imaging-guided laser interstitial thermal therapy as treatment for intractable insular epilepsy in children.

    PubMed

    Perry, M Scott; Donahue, David J; Malik, Saleem I; Keator, Cynthia G; Hernandez, Angel; Reddy, Rohit K; Perkins, Freedom F; Lee, Mark R; Clarke, Dave F

    2017-12-01

    OBJECTIVE Seizure onset within the insula is increasingly recognized as a cause of intractable epilepsy. Surgery within the insula is difficult, with considerable risks, given the rich vascular supply and location near critical cortex. MRI-guided laser interstitial thermal therapy (LiTT) provides an attractive treatment option for insular epilepsy, allowing direct ablation of abnormal tissue while sparing nearby normal cortex. Herein, the authors describe their experience using this technique in a large cohort of children undergoing treatment of intractable localization-related epilepsy of insular onset. METHODS The combined epilepsy surgery database of Cook Children's Medical Center and Dell Children's Hospital was queried for all cases of insular onset epilepsy treated with LiTT. Patients without at least 6 months of follow-up data and cases preoperatively designated as palliative were excluded. Patient demographics, presurgical evaluation, surgical plan, and outcome were collected from patient charts and described. RESULTS Twenty patients (mean age 12.8 years, range 6.1-18.6 years) underwent a total of 24 LiTT procedures; 70% of these patients had normal findings on MRI. Patients underwent a mean follow-up of 20.4 months after their last surgery (range 7-39 months), with 10 (50%) in Engel Class I, 1 (5%) in Engel Class II, 5 (25%) in Engel Class III, and 4 (20%) in Engel Class IV at last follow-up. Patients were discharged within 24 hours of the procedure in 15 (63%) cases, in 48 hours in 6 (24%) cases, and in more than 48 hours in the remaining cases. Adverse functional effects were experienced following 7 (29%) of the procedures: mild hemiparesis after 6 procedures (all patients experienced complete resolution or had minimal residual dysfunction by 6 months), and expressive language dysfunction after 1 procedure (resolved by 3 months). CONCLUSIONS To their knowledge, the authors present the largest cohort of pediatric patients undergoing insular surgery for treatment of intractable epilepsy. The patient outcomes suggest that LiTT can successfully treat intractable seizures originating within the insula and offers an attractive alternative to open resection. This is the first description of LiTT applied to insular epilepsy and represents one of only a few series describing the use of LiTT in children. The results indicate that seizure reduction after LiTT compares favorably to that after conventional open surgical techniques.

  13. Treatment of advanced melanoma with laser immunotherapy and ipilimumab.

    PubMed

    Naylor, Mark F; Zhou, Feifan; Geister, Brian V; Nordquist, Robert E; Li, Xiaosong; Chen, Wei R

    2017-05-01

    Immunotherapy has become a promising modality for melanoma, especially using checkpoint inhibitors, which revive suppressed T cells against the cancer. Such inhibitors should work better when combined with other treatments which could increase the number and quality of anti-tumor T cells. We treated one patient with advanced (stage IV) melanoma, using the combination of laser immunotherapy (LIT), a novel immunological approach for metastatic cancers that has been shown to stimulate adaptive immunity, and ipilimumab. The patient was treated with LIT, followed with one course of ipilimumab 3 months after the beginning of LIT. After LIT treatment, all treated cutaneous melanoma in head and neck cleared completely. After the application of ipilimumab, all the tumor nodules in the lungs decreased. The patient had remained tumor free for one year. While anecdotal, the responses seen in this patient support the hypothesis that laser immunotherapy increases the number and quality of anti-tumor T cells so that ipilimumab and other checkpoint inhibitors are more effective in enhancing the therapeutic effects. Picture: Schematic of treatment using laser immunotherapy and ipilimumab on a stage IV melanoma patient. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. New Class of Excimer-Pumped Atomic Lasers (XPALS)

    DTIC Science & Technology

    2017-01-27

    quantum efficiency greater thnn one, has been demonstrated. We believe this laser to represent a breakthrough in laser technology because the system...navy.mil Prepared by J. G. Eden and A. E. Mironov Laboratory For Optical Physics and Engineering Department of Electrical and Computer Engineering...viability of an atomic laser having a quantum efficiency greater than one. We believe this laser to represent a breakthrough in laser technology

  15. Q-Switching in a Neodymium Laser

    ERIC Educational Resources Information Center

    Holgado, Warein; Sola, Inigo J.; Jarque, Enrique Conejero; Jarabo, Sebastian; Roso, Luis

    2012-01-01

    We present a laboratory experiment for advanced undergraduate or graduate laser-related classes to study the performance of a neodymium laser. In the experiment, the student has to build the neodymium laser using an open cavity. After that, the cavity losses are modulated with an optical chopper located inside, so the Q-switching regime is…

  16. 2D and 3D T2-weighted MR sequences for the assessment of neurovascular bundle changes after nerve-sparing radical retropubic prostatectomy with erectile function correlation.

    PubMed

    Panebianco, Valeria; Sciarra, Alessandro; Osimani, Marcello; Lisi, Danilo; Ciccariello, Mauro; Salciccia, Stefano; Gentile, Vincenzo; Di Silverio, Franco; Passariello, Roberto

    2009-01-01

    The aim of this study was to assess the capability of a 3D isotropic MRI T2-weighted sequence (3D T2 ISO) in the depiction of changes of neurovascular bundles (NVBs) after bilateral nerve-sparing radical retropubic prostatectomy (RRP). Furthermore, our aim was also to introduce a new MRI classification score of the NVB alteration patterns using the International Index Erectile Function Five-Item (IIEF-5) score as standard of reference. Fifty-three consecutive patients were postoperatively submitted to two MR examinations, including both 2D TSE T2-weighted (2D T2) and 3D T2 ISO sequences. Image findings were scored using a relative five-point classification and correlated with the postoperative IIEF-5 score. Radiologists attributed 13.2% of patients to class 0, 11.3% to class I, 34% to class II, 24.5% to class III, and 16.9% to class IV. With 3D T2 ISO images, the same radiologists determined 43.3% class 0, 32% class I, 11.4% class II, 7.5% class III, and 5.7% class IV. In all cases, the correlation and regression analysis between the 3D T2 ISO and IIEF-5 score resulted in higher coefficients values. The 3D sequence correlated most closely with patients' grading of erectile function.

  17. 40 CFR 90.104 - Compliance with emission standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Volume Engine Families Engine class Two-stroke engines 1 HC+NOX CO Four-stroke engines HC+NOX CO Engines...). Class IV 1.1 1.1 1.5 1.1 Class V 1.1 1.1 1.5 1.1 1 Two-stroke technologies to which these assigned deterioration factors apply include conventional two-strokes, compression wave designs, and stratified...

  18. 40 CFR 90.104 - Compliance with emission standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Volume Engine Families Engine class Two-stroke engines 1 HC+NOX CO Four-stroke engines HC+NOX CO Engines...). Class IV 1.1 1.1 1.5 1.1 Class V 1.1 1.1 1.5 1.1 1 Two-stroke technologies to which these assigned deterioration factors apply include conventional two-strokes, compression wave designs, and stratified...

  19. 40 CFR 90.104 - Compliance with emission standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Volume Engine Families Engine class Two-stroke engines 1 HC+NOX CO Four-stroke engines HC+NOX CO Engines...). Class IV 1.1 1.1 1.5 1.1 Class V 1.1 1.1 1.5 1.1 1 Two-stroke technologies to which these assigned deterioration factors apply include conventional two-strokes, compression wave designs, and stratified...

  20. 40 CFR 90.104 - Compliance with emission standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Volume Engine Families Engine class Two-stroke engines 1 HC+NOX CO Four-stroke engines HC+NOX CO Engines...). Class IV 1.1 1.1 1.5 1.1 Class V 1.1 1.1 1.5 1.1 1 Two-stroke technologies to which these assigned deterioration factors apply include conventional two-strokes, compression wave designs, and stratified...

  1. 40 CFR 90.104 - Compliance with emission standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Volume Engine Families Engine class Two-stroke engines 1 HC+NOX CO Four-stroke engines HC+NOX CO Engines...). Class IV 1.1 1.1 1.5 1.1 Class V 1.1 1.1 1.5 1.1 1 Two-stroke technologies to which these assigned deterioration factors apply include conventional two-strokes, compression wave designs, and stratified...

  2. 76 FR 56833 - Self-Regulatory Organizations; BATS Y-Exchange, Inc.; Notice of Filing of Proposed Rule Change To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-14

    ... respective voting rights and of Class A and Class B common stock, (iv) setting forth certain limitations on... Incorporation, shares of Non-Voting Common Stock possess the same rights, preferences, powers, privileges... B Common Stock. Except for voting rights and certain conversion features, as described below, Class...

  3. 76 FR 56840 - Self-Regulatory Organizations; BATS Exchange, Inc.; Notice of Filing of Proposed Rule Change To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-14

    ... respective voting rights and of Class A and Class B common stock, (iv) setting forth certain limitations on... Incorporation, shares of Non-Voting Common Stock possess the same rights, preferences, powers, privileges...-Voting Class B Common Stock. Except for voting rights and certain conversion features, as described below...

  4. 77 FR 24978 - Notice of Proposed Class II Reinstatement of Terminated Oil and Gas Leases, Utah.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-26

    ... Proposed Class II Reinstatement of Terminated Oil and Gas Leases, Utah. AGENCY: Bureau of Land Management, Interior. ACTION: Notice of Proposed Class II Reinstatement of Terminated Oil and Gas Leases, Utah. SUMMARY: In accordance with Title IV of the Federal Oil and Gas Royalty Management Act (Pub. L. 97-451...

  5. 76 FR 14686 - Notice of Proposed Class II Reinstatement of Terminated Oil and Gas Lease, Utah

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-17

    ... Proposed Class II Reinstatement of Terminated Oil and Gas Lease, Utah AGENCY: Bureau of Land Management, Interior. ACTION: Notice of Proposed Class II Reinstatement of Terminated Oil and Gas Lease, Utah. SUMMARY: In accordance with Title IV of the Federal Oil and Gas Royalty Management Act (Pub. L. 97-451...

  6. Vulnerability of CMOS image sensors in Megajoule Class Laser harsh environment.

    PubMed

    Goiffon, V; Girard, S; Chabane, A; Paillet, P; Magnan, P; Cervantes, P; Martin-Gonthier, P; Baggio, J; Estribeau, M; Bourgade, J-L; Darbon, S; Rousseau, A; Glebov, V Yu; Pien, G; Sangster, T C

    2012-08-27

    CMOS image sensors (CIS) are promising candidates as part of optical imagers for the plasma diagnostics devoted to the study of fusion by inertial confinement. However, the harsh radiative environment of Megajoule Class Lasers threatens the performances of these optical sensors. In this paper, the vulnerability of CIS to the transient and mixed pulsed radiation environment associated with such facilities is investigated during an experiment at the OMEGA facility at the Laboratory for Laser Energetics (LLE), Rochester, NY, USA. The transient and permanent effects of the 14 MeV neutron pulse on CIS are presented. The behavior of the tested CIS shows that active pixel sensors (APS) exhibit a better hardness to this harsh environment than a CCD. A first order extrapolation of the reported results to the higher level of radiation expected for Megajoule Class Laser facilities (Laser Megajoule in France or National Ignition Facility in the USA) shows that temporarily saturated pixels due to transient neutron-induced single event effects will be the major issue for the development of radiation-tolerant plasma diagnostic instruments whereas the permanent degradation of the CIS related to displacement damage or total ionizing dose effects could be reduced by applying well known mitigation techniques.

  7. Multidisciplinary and multisetting team management programme in heart failure patients affects hospitalisation and costing.

    PubMed

    Piepoli, M F; Villani, G Q; Aschieri, D; Bennati, S; Groppi, F; Pisati, M S; Rosi, A; Capucci, A

    2006-08-28

    We evaluated whether multidisciplinary disease management programme developed with collaboration of physicians and nurses inside and outside general district hospital settings can affect clinical outcomes in heart failure population over a 12-month period. 571 patients hospitalised with CHF were referred to our unit and 509 patients agreed to participation. The intervention team included physicians and nurses from Internal Medicine and Cardiac Dept., and the patient's general practitioners. Contacts were on a pre-specified schedule, included a computerised programme of hospital visits and phone calls; in case of NYHA functional class III and IV patients, home visits were also planned. The median age of patients was 77.7+/-9 years (43.3% women). At baseline the percentage of patients with NYHA class III and IV was 56.0% vs. 26.0% after 12 months (P<0.05). Programme enrolment reduced total hospital admissions (82 vs. 190, -56%, P<0.05), number of patients hospitalised (62 vs. 146, 57%, P<0.05). All NYHA functional class benefited (class I=75%, class IV=67%), with reduction in the costing (-48%, P<0.05). Improvement in symptoms (-9.0+/-3.2) and signs (-5.2+/-3.1) scores was measured (P<0.01). Therapy optimisation was obtained by 20.5% increase in patients taking betablockade and 21.0% increase in those on anti-aldosterone drugs. Multidisciplinary approach to CHF management can improve clinical management, reducing hospitalisation rate and costing.

  8. Repellent and Anti-quorum Sensing Activity of Six Aromatic Plants Occurring in Colombia.

    PubMed

    Cervantes-Ceballos, Leonor; Caballero-Gallardo, Karina; Olivero-Verbel, Jesus

    2015-10-01

    Essential oils (EOs) are widely used as biopesticides and to control bacterial infections. This study describes the ability of six EOs isolated from plants cultivated in Colombia to perform as repellents against Ulomoides dermestoides and as quorum sensing (QS) inhibitors. EOs from Aloysia triphylla, Cymbopogon nardus, Lippia origanoides, Hyptis suaveolens, Swinglea glutinosa and Eucalyptus globulus were repellents classified as Class IV, IV, IV, III, II, and II, respectively, whereas the commercial repellent IR3535 only reached Class II after 2 h exposure. All EOs presented small, but significant inhibitory properties against the QS system in Escherichia coli (pJBA132) at 25 μg/mL after 4 h exposure. These data suggest evaluated EOs from Colombia are sustainable, promising new sources of natural repellents and could be important as anti-quorum sensing molecules.

  9. 14 CFR 61.5 - Certificates and ratings issued under this part.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... (iii) Glider. (iv) Lighter-than-air. (v) Powered-lift. (vi) Powered parachute. (vii) Weight-shift...—Airplane. (ii) Instrument—Helicopter. (iii) Instrument—Powered-lift. (c) The following ratings are placed.... (iii) Glider. (iv) Powered-lift. (2) Airplane class ratings— (i) Single-engine. (ii) Multiengine. (3...

  10. 14 CFR 61.5 - Certificates and ratings issued under this part.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... (iii) Glider. (iv) Lighter-than-air. (v) Powered-lift. (vi) Powered parachute. (vii) Weight-shift...—Airplane. (ii) Instrument—Helicopter. (iii) Instrument—Powered-lift. (c) The following ratings are placed.... (iii) Glider. (iv) Powered-lift. (2) Airplane class ratings— (i) Single-engine. (ii) Multiengine. (3...

  11. [Clinical study on vocal cords spontaneous rehabilitation after CO2 laser surgery].

    PubMed

    Zhang, Qingxiang; Hu, Huiying; Sun, Guoyan; Yu, Zhenkun

    2014-10-01

    To study the spontaneous rehabilitation and phonation quality of vocal cords after different types of CO2 laser microsurgery. Surgical procedures based on Remacle system Type I, Type II, Type III, Type IV and Type V a respectively. Three hundred and fifteen cases with hoarseness based on strobe laryngoscopy results were prospectively assigned to different group according to vocal lesions apperence,vocal vibration and imaging of larynx CT/MRI. Each group holded 63 cases. The investigation included the vocal cords morphological features,the patients' subjective feelings and objective results of vocal cords. There are no severe complications for all patients in perioperative period. Vocal scar found in Type I ,1 case; Type II, 9 cases ;Type III, 47 cases; Type IV, 61 cases and Type Va 63 cases respectively after surgery. The difference of Vocal scar formation after surgery between surgical procedures are statistical significance (χ2 = 222.24, P < 0.05). Hoarseness improved after the surgery in 59 cases of Type I , 51 cases of Type II, 43 cases of Type III, 21 cases of Type IV and 17 cases of Type Va. There are statistically significance (χ2 = 89.46, P < 0.05) between different surgical procedures. The parameters of strobe laryngoscope: there are statistical significance on jitter between procedures (F 44.51, P < 0.05), but without difference within Type I and Type II (P > 0.05). This happened in shimmer parameter and the maximum phonation time (MPT) as jitter. There are no statistical significance between Type IV and Type Va on MPT (P > 0.05). Morphological and functional rehabilitation of vocal cord will be affected obviously when the body layer is injured. The depth and range of the CO2 laser microsurgery are the key factors affecting the vocal rehabilitation.

  12. Tailoring Laser Propulsion for Future Applications in Space

    NASA Astrophysics Data System (ADS)

    Eckel, Hans-Albert; Scharring, Stefan

    2010-10-01

    Pulsed laser propulsion may turn out as a low cost alternative for the transportation of small payloads in future. In recent years DLR investigated this technology with the goal of cheaply launching small satellites into low earth orbit (LEO) with payload masses on the order of 5 to 10 kg. Since the required high power pulsed laser sources are yet not at the horizon, DLR focused on new applications based on available laser technology. Space-borne, i.e. in weightlessness, there exist a wide range of missions requiring small thrusters that can be propelled by laser power. This covers space logistic and sample return missions as well as position keeping and attitude control of satellites. First, a report on the proof of concept of a remote controlled laser rocket with a thrust vector steering device integrated in a parabolic nozzle will be given. Second, the road from the previous ground-based flight experiments in earth's gravity using a 100-J class laser to flight experiments with a parabolic thruster in an artificial 2D-zero gravity on an air cushion table employing a 1-J class laser and, with even less energy, new investigations in the field of laser micro propulsion will be reviewed.

  13. Exploring new classification criteria for the earliest type stars: the 3400 Aregion

    NASA Astrophysics Data System (ADS)

    Morrell, Nidia I.; Walborn, Nolan R.; Arias, Julia I.

    2002-02-01

    We propose spectroscopic observations of a sample of standard O2-O4 stars in the wavelength region containing the N IV 3479-83-85 Aand O IV 3381-85-3412 Alines, in order to analyze the behavior of these spectral features as a function of the spectral type. We aim to define new classification criteria for the hottest stars, evaluating these N IV and O IV lines near 3400 Aas possible temperature and luminosity discriminators. The former spectral class O3 has just been split into three different classes: O2, O3 and O3.5 (Walborn et al. 2001). The paucity of classification criteria at these types in the traditional wavelength domain (4000 - 4700 Å), makes clear the need to explore other spectral ranges in order to define additional constraints on the determination of spectral types and luminosity classes. The wavelength range around 3400 Ahas been observed in many faint, crowded early O-type stars by HST/FOS, the corresponding data being available from the HST archive. This enhances our interest in observing this spectral range in the classification standards for the early O-type stars in order to make these existing HST observations even more useful, allowing the determination of accurate spectral types for unknown objects from them, once the behavior of the new criteria in the standards has been charted.

  14. Surface modification of titanium nitride film by a picosecond Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Gakovic, B.; Trtica, M.; Batani, D.; Desai, T.; Panjan, P.; Vasiljevic-Radovic, D.

    2007-06-01

    The interaction of a picosecond Nd:YAG laser (wavelength 532 nm, pulse duration 40 ps) with a polycrystalline titanium nitride (TiN) film was studied. The TiN thin film was deposited by physical vapour deposition on a silicon substrate. The titanium nitride/silicon system was modified with an energy fluence from 0.2 to 5.9 J cm-2. Multi-pulse irradiation was performed in air by a focused laser beam. Surface modifications were analysed after 1 100 successive laser pulses. Depending on the laser pulse energy and pulse count, the following phenomena were observed: (i) increased surface roughness, (ii) titanium nitride film cracking, (iii) silicon substrate modification, (iv) film exfoliation and (v) laser-induced periodical surface structures on nano- (NPSS) and micro-dimensions (MPSS).

  15. IV INTERNATIONAL CONFERENCE ON ATOM AND MOLECULAR PULSED LASERS (AMPL'99): Radiative and photochemical properties of organic compounds excited by high-power XeCl laser radiation

    NASA Astrophysics Data System (ADS)

    Kopylova, T. N.; Kuznetsova, Rimma T.; Svetlichnyi, Valerii A.; Sergeev, A. K.; Tel'minov, E. N.; Filinov, D. N.

    2000-06-01

    Radiative and photochemical properties of a number of laser dyes excited by focused radiation of a XeCl laser with intensity up to 200 MW cm-2 were studied. A method for measuring the gain of organic molecules under high-power excitation is proposed. The dependence of the dye transmittance for the pump radiation on its intensity was studied. It is shown that changes in energy, spectral, and time characteristics of radiation and the photostability of compounds under high-power excitation are associated with the formation of superluminescence.

  16. Assessment of microleakage of class V restored by resin composite and resin-modified glass ionomer and pit and fissure resin-based sealants following Er:YAG laser conditioning and acid etching: in vitro study

    PubMed Central

    Luong, Emilie; Shayegan, Amir

    2018-01-01

    Aim The aim of this study was to make a comparison between microleakage of conventionally restored class V cavities using acid etchant and the ones conditioned by erbium-doped yttrium aluminum garnet (Er:YAG) laser, and also to assess and compare the effectiveness of enamel surface treatments of occlusal pits and fissures by acid etching and conditioned by Er:YAG laser-etch. Materials and methods Seventy-two extracted third molars were used in this study. The samples were divided into two major groups: class V cavities and pit and fissure sealants. Each subgroup was divided into conventional acid etching, Er:YAG laser conditioning and conventional acid etching, and combination with Er:YAG laser conditioning (n=12). The teeth were placed in 2% methylene blue dye solution, were sectioned, and were evaluated according to the dye penetration criteria. Two samples per subgroup were chosen for scanning electron microscopic (SEM) analysis. Results There was a significant difference between occlusal and cervical margin groups. Laser conventional composite cementum group showed more microleakage values compared to other groups. There was no significant difference between occlusal margin groups. However, there was a significant difference between cervical margin groups in terms of microleakage. In sealant groups, there was a significant difference between laser and conventional with/without laser treatment groups in terms of microleakage. Conclusion Based on the results reported in this study, it can be concluded that the application of the Er:YAG laser beneath the resin composite, the resin-modified glass ionomers (GIs), and the fissure sealant placement may be an alternative enamel and dentin etching method to acid etching. PMID:29881311

  17. 2D phase tomography of biotissues: IV. Wavelet processing of phase tomograms of the background and precancerous endometrial states

    NASA Astrophysics Data System (ADS)

    Peresunko, A. P.; Zavadovskya, I. G.

    2004-06-01

    The paper deals with the studying of prognostic possibilities of determining the orientation structure of endometrial strome in the normal state and hiperplasia. The laser diagnostic of endometrial state is based on the principles of optical changes of laser radiation during its passing through the histological sample with the following investigation of its wavelet coefficients.

  18. Origin of terminal voltage variations due to self-mixing in terahertz frequency quantum cascade lasers.

    PubMed

    Grier, Andrew; Dean, Paul; Valavanis, Alexander; Keeley, James; Kundu, Iman; Cooper, Jonathan D; Agnew, Gary; Taimre, Thomas; Lim, Yah Leng; Bertling, Karl; Rakić, Aleksandar D; Li, Lianhe H; Harrison, Paul; Linfield, Edmund H; Ikonić, Zoran; Davies, A Giles; Indjin, Dragan

    2016-09-19

    We explain the origin of voltage variations due to self-mixing in a terahertz (THz) frequency quantum cascade laser (QCL) using an extended density matrix (DM) approach. Our DM model allows calculation of both the current-voltage (I-V) and optical power characteristics of the QCL under optical feedback by changing the cavity loss, to which the gain of the active region is clamped. The variation of intra-cavity field strength necessary to achieve gain clamping, and the corresponding change in bias required to maintain a constant current density through the heterostructure is then calculated. Strong enhancement of the self-mixing voltage signal due to non-linearity of the (I-V) characteristics is predicted and confirmed experimentally in an exemplar 2.6 THz bound-to-continuum QCL.

  19. Assessment: transcranial Doppler ultrasonography: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology.

    PubMed

    Sloan, M A; Alexandrov, A V; Tegeler, C H; Spencer, M P; Caplan, L R; Feldmann, E; Wechsler, L R; Newell, D W; Gomez, C R; Babikian, V L; Lefkowitz, D; Goldman, R S; Armon, C; Hsu, C Y; Goodin, D S

    2004-05-11

    To review the use of transcranial Doppler ultrasonography (TCD) and transcranial color-coded sonography (TCCS) for diagnosis. The authors searched the literature for evidence of 1) if TCD provides useful information in specific clinical settings; 2) if using this information improves clinical decision making, as reflected by improved patient outcomes; and 3) if TCD is preferable to other diagnostic tests in these clinical situations. TCD is of established value in the screening of children aged 2 to 16 years with sickle cell disease for stroke risk (Type A, Class I) and the detection and monitoring of angiographic vasospasm after spontaneous subarachnoid hemorrhage (Type A, Class I to II). TCD and TCCS provide important information and may have value for detection of intracranial steno-occlusive disease (Type B, Class II to III), vasomotor reactivity testing (Type B, Class II to III), detection of cerebral circulatory arrest/brain death (Type A, Class II), monitoring carotid endarterectomy (Type B, Class II to III), monitoring cerebral thrombolysis (Type B, Class II to III), and monitoring coronary artery bypass graft operations (Type B to C, Class II to III). Contrast-enhanced TCD/TCCS can also provide useful information in right-to-left cardiac/extracardiac shunts (Type A, Class II), intracranial occlusive disease (Type B, Class II to IV), and hemorrhagic cerebrovascular disease (Type B, Class II to IV), although other techniques may be preferable in these settings.

  20. Risk prediction with procalcitonin and clinical rules in community-acquired pneumonia

    PubMed Central

    Huang, David T.; Weissfeld, Lisa A.; Kellum, John A.; Yealy, Donald M.; Kong, Lan; Martino, Michael; Angus, Derek C.

    2009-01-01

    Objective The Pneumonia Severity Index (PSI) and CURB-65 predict outcomes in community acquired pneumonia (CAP), but have limitations. Procalcitonin, a biomarker of bacterial infection, may provide prognostic information in CAP. Our objective was to describe the pattern of procalcitonin in CAP, and determine if procalcitonin provides prognostic information beyond PSI and CURB-65. Methods We conducted a multi-center prospective cohort study in 28 community and teaching emergency departments. Patients presenting with a clinical and radiographic diagnosis of CAP were enrolled. We stratified procalcitonin levels a priori into four tiers – I: < 0.1; II: ≥ 0.1 to <0.25; III: ≥ 0.25 to < 0.5; and IV: ≥ 0.5 ng/ml. Primary outcome was 30d mortality. Results 1651 patients formed the study cohort. Procalcitonin levels were broadly spread across tiers: 32.8% (I), 21.6% (II), 10.2% (III), 35.4% (IV). Used alone, procalcitonin had modest test characteristics: specificity (35%), sensitivity (92%), positive likelihood ratio (LR) (1.41), and negative LR (0.22). Adding procalcitonin to PSI in all subjects minimally improved performance. Adding procalcitonin to low risk PSI subjects (Class I–III) provided no additional information. However, subjects in procalcitonin tier I had low 30d mortality regardless of clinical risk, including those in higher risk classes (1.5% vs. 1.6% for those in PSI Class I–III vs. Class IV/V). Among high risk PSI subjects (Class IV/V), one quarter (126/546) were in procalcitonin tier I, and the negative LR of procalcitonin tier I was 0.09. Procalcitonin tier I was also associated with lower burden of other adverse outcomes. Similar results were seen with CURB-65 stratification. Conclusions Selective use of procalcitonin as an adjunct to existing rules may offer additional prognostic information in high risk patients. PMID:18342993

  1. Long-term benefit of early pre-reperfusion metoprolol administration in patients with acute myocardial infarction: results from the METOCARD-CNIC trial (Effect of Metoprolol in Cardioprotection During an Acute Myocardial Infarction).

    PubMed

    Pizarro, Gonzalo; Fernández-Friera, Leticia; Fuster, Valentin; Fernández-Jiménez, Rodrigo; García-Ruiz, José M; García-Álvarez, Ana; Mateos, Alonso; Barreiro, María V; Escalera, Noemí; Rodriguez, Maite D; de Miguel, Antonio; García-Lunar, Inés; Parra-Fuertes, Juan J; Sánchez-González, Javier; Pardillos, Luis; Nieto, Beatriz; Jiménez, Adriana; Abejón, Raquel; Bastante, Teresa; Martínez de Vega, Vicente; Cabrera, José A; López-Melgar, Beatriz; Guzman, Gabriela; García-Prieto, Jaime; Mirelis, Jesús G; Zamorano, José Luis; Albarrán, Agustín; Goicolea, Javier; Escaned, Javier; Pocock, Stuart; Iñiguez, Andrés; Fernández-Ortiz, Antonio; Sánchez-Brunete, Vicente; Macaya, Carlos; Ibanez, Borja

    2014-06-10

    The goal of this trial was to study the long-term effects of intravenous (IV) metoprolol administration before reperfusion on left ventricular (LV) function and clinical events. Early IV metoprolol during ST-segment elevation myocardial infarction (STEMI) has been shown to reduce infarct size when used in conjunction with primary percutaneous coronary intervention (pPCI). The METOCARD-CNIC (Effect of Metoprolol in Cardioprotection During an Acute Myocardial Infarction) trial recruited 270 patients with Killip class ≤II anterior STEMI presenting early after symptom onset (<6 h) and randomized them to pre-reperfusion IV metoprolol or control group. Long-term magnetic resonance imaging (MRI) was performed on 202 patients (101 per group) 6 months after STEMI. Patients had a minimal 12-month clinical follow-up. Left ventricular ejection fraction (LVEF) at the 6 months MRI was higher after IV metoprolol (48.7 ± 9.9% vs. 45.0 ± 11.7% in control subjects; adjusted treatment effect 3.49%; 95% confidence interval [CI]: 0.44% to 6.55%; p = 0.025). The occurrence of severely depressed LVEF (≤35%) at 6 months was significantly lower in patients treated with IV metoprolol (11% vs. 27%, p = 0.006). The proportion of patients fulfilling Class I indications for an implantable cardioverter-defibrillator (ICD) was significantly lower in the IV metoprolol group (7% vs. 20%, p = 0.012). At a median follow-up of 2 years, occurrence of the pre-specified composite of death, heart failure admission, reinfarction, and malignant arrhythmias was 10.8% in the IV metoprolol group versus 18.3% in the control group, adjusted hazard ratio (HR): 0.55; 95% CI: 0.26 to 1.04; p = 0.065. Heart failure admission was significantly lower in the IV metoprolol group (HR: 0.32; 95% CI: 0.015 to 0.95; p = 0.046). In patients with anterior Killip class ≤II STEMI undergoing pPCI, early IV metoprolol before reperfusion resulted in higher long-term LVEF, reduced incidence of severe LV systolic dysfunction and ICD indications, and fewer heart failure admissions. (Effect of METOprolol in CARDioproteCtioN During an Acute Myocardial InfarCtion. The METOCARD-CNIC Trial; NCT01311700). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Optically Driven Spin Based Quantum Dots for Quantum Computing

    DTIC Science & Technology

    2008-01-01

    time . Figure 3. Demonstration of optical pumping. This shows the absorption as a function of bias voltage and laser energy. In region...319,076 319,079 0 2 0 2 0 2 0 2 0 2 R el at iv e ab so rp tio n (× 1 0– 4 ) Probe frequency (GHz) Time constant (ms) 1 1 3 10 30 c Figure 1 | Laser ...spectrum of the forward (or backward) scan. c, The probe absorption spectrum as a function of the laser scan rate, indicated by the lock-in time

  3. Laser induced fluorescence technique for environmental applications

    NASA Astrophysics Data System (ADS)

    Utkin, Andrei B.; Felizardo, Rui; Gameiro, Carla; Matos, Ana R.; Cartaxana, Paulo

    2014-08-01

    We discuss the development of laser induced fluorescence sensors and their application in the evaluation of water pollution and physiological status of higher plants and algae. The sensors were built on the basis of reliable and robust solid-state Nd:YAG lasers. They demonstrated good efficiency in: i) detecting and characterizing oil spills and dissolved organic matter; ii) evaluating the impact of stress on higher plants (cork oak, maritime pine, and genetically modified Arabidopsis); iii) tracking biomass changes in intertidal microphytobenthos; and iv) mapping macroalgal communities in the Tagus Estuary.

  4. Analysis of Phospholipid Mixtures from Biological Tissues by Matrix-Assisted Laser Desorption and Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS): A Laboratory Experiment

    ERIC Educational Resources Information Center

    Eibisch, Mandy; Fuchs, Beate; Schiller, Jurgen; Sub, Rosmarie; Teuber, Kristin

    2011-01-01

    Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) is increasingly used to investigate the phospholipid (PL) compositions of tissues and body fluids, often without previous separation of the total mixture into the individual PL classes. Therefore, the questions of whether all PL classes are detectable…

  5. Nonlocal systems of balance laws in several space dimensions with applications to laser technology

    NASA Astrophysics Data System (ADS)

    Colombo, Rinaldo M.; Marcellini, Francesca

    2015-12-01

    For a class of systems of nonlinear and nonlocal balance laws in several space dimensions, we prove the local in time existence of solutions and their continuous dependence on the initial datum. The choice of this class is motivated by a new model devoted to the description of a metal plate being cut by a laser beam. Using realistic parameters, solutions to this model obtained through numerical integrations meet qualitative properties of real cuts. Moreover, the class of equations considered comprises a model describing the dynamics of solid particles along a conveyor belt.

  6. Effect of laser infrared therapy on several rheological indices of blood and on the homeostasis of patients with post-infarction cardiosclerosis

    NASA Astrophysics Data System (ADS)

    Volov, N. A.; Kudinova, M. A.; Fedulaeva, A. I.; Fedulaev, Yu. N.; Gordeev, I. G.

    2001-04-01

    An investigation was made on 38 patients affected by exertion angina pectoris of the I-III functional classes. The patients survived a Q-associated myocardial infarction not earlier than 1 year ago. The patients were treated according to a 10-session course of laser infrared therapy. The dynamics of several hemorheological indices (such as blood viscosity, the hematocrit of venous blood, fibrinogen, fibronectine, thrombocyte aggregation, antithrombin III, and the activated partial thrombplastin time) was estimated prior to the treatment, 5 - 7 days after the beginning of laser therapy, and 30 days after the beginning of laser therapy treatment. It was found that laser therapy was capable of producing a significant decrease in the blood viscosity, fibrinogen level, and in the aggregation of thrombocytes. Moreover, laser infrared therapy carried out on patients affected by post-infarction cardiosclerosis and by stable exertion stenocardia of the I-III functional classes produced a reliable normalization of hemorheological indices of the blood.

  7. Investigations of gain redshift in high peak power Ti:sapphire laser systems

    NASA Astrophysics Data System (ADS)

    Wu, Fenxiang; Yu, Linpeng; Zhang, Zongxin; Li, Wenkai; Yang, Xiaojun; Wu, Yuanfeng; Li, Shuai; Wang, Cheng; Liu, Yanqi; Lu, Xiaoming; Xu, Yi; Leng, Yuxin

    2018-07-01

    Gain redshift in high peak power Ti:sapphire laser systems can result in narrowband spectral output and hence lengthen the compressed pulse duration. In order to realize broadband spectral output in 10 PW-class Ti:sapphire lasers, the influence on gain redshift induced by spectral pre-shaping, gain distribution of cascaded amplifiers and Extraction During Pumping (EDP) technique have been investigated. The theoretical and experimental results show that the redshift of output spectrum is sensitive to the spectral pre-shaping and the gain distribution of cascaded amplifiers, while insensitive to the pumping scheme with or without EDP. Moreover, the output spectrum from our future 10 PW Ti:sapphire laser is theoretically analyzed based on the investigations above, which indicates that a Fourier-transform limited (FTL) pulse duration of 21 fs can be achieved just by optimizing the spectral pre-shaping and gain distribution in 10 PW-class Ti:sapphire lasers.

  8. Addressing Control of Hazardous Energy (COHE) Requirements in a Laser Safety Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woods, Michael; /SLAC

    OSHA regulation 29CFR1910.147 specifies control of hazardous energy requirements for 'the servicing and maintenance of machines and equipment in which the unexpected energization or start up of the machines or equipment, or release of stored energy could cause injury to employees.' Class 3B and Class 4 laser beams must be considered hazardous energy sources because of the potential for serious eye injury; careful consideration is therefore needed to safely de-energize these lasers. This paper discusses and evaluates control of hazardous energy principles in this OSHA regulation, in ANSI Z136.1 ''Safe Use of Lasers,'' and in ANSI Z244.1 ''Control of Hazardousmore » Energy, Lockout/Tagout and Alternative Methods.'' Recommendations are made for updating and improving CoHE (control of hazardous energy) requirements in these standards for their applicability to safe laser operations.« less

  9. Investigating the Capability of IRS-P6-LISS IV Satellite Image for Pistachio Forests Density Mapping (case Study: Northeast of Iran)

    NASA Astrophysics Data System (ADS)

    Hoseini, F.; Darvishsefat, A. A.; Zargham, N.

    2012-07-01

    In order to investigate the capability of satellite images for Pistachio forests density mapping, IRS-P6-LISS IV data were analyzed in an area of 500 ha in Iran. After geometric correction, suitable training areas were determined based on fieldwork. Suitable spectral transformations like NDVI, PVI and PCA were performed. A ground truth map included of 34 plots (each plot 1 ha) were prepared. Hard and soft supervised classifications were performed with 5 density classes (0-5%, 5-10%, 10-15%, 15-20% and > 20%). Because of low separability of classes, some classes were merged and classifications were repeated with 3 classes. Finally, the highest overall accuracy and kappa coefficient of 70% and 0.44, respectively, were obtained with three classes (0-5%, 5-20%, and > 20%) by fuzzy classifier. Considering the low kappa value obtained, it could be concluded that the result of the classification was not desirable. Therefore, this approach is not appropriate for operational mapping of these valuable Pistachio forests.

  10. 75 FR 27785 - Final Effect of Designation of a Class of Employees for Addition to the Special Exposure Cohort

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Final Effect of Designation of a Class of Employees for Addition to the Special Exposure Cohort AGENCY: National Institute for Occupational Safety and Health... concerning the final effect of the decision to designate a class of employees from Area IV of the Santa...

  11. [Evaluation of a chronic fatigue in patients with moderate-to-severe chronic heart failure].

    PubMed

    Jasiukeviciene, Lina; Vasiliauskas, Donatas; Kavoliūniene, Ausra; Marcinkeviciene, Jolanta; Grybauskiene, Regina; Grizas, Vytautas; Tumyniene, Vida

    2008-01-01

    To evaluate the chronic fatigue and its relation to the function of hypothalamus-pituitary-adrenal axis in patients with New York Heart Association (NYHA) functional class III-IV chronic heart failure. A total of 170 patients with NYHA functional class III-IV chronic heart failure completed MFI-20L, DUFS, and DEFS questionnaires assessing chronic fatigue and underwent echocardiography. Blood cortisol concentration was assessed at 8:00 am and 3:00 pm, and plasma N-terminal brain natriuretic pro-peptide (NT-proBNP) concentration was measured at 8:00 am. Neurohumoral investigations were repeated before cardiopulmonary exercise test and after it. The results of all questionnaires showed that 100% of patients with NYHA functional class III-IV heart failure complained of chronic fatigue. The level of overall fatigue was 54.5+/-31.5 points; physical fatigue - 56.8+/-24.6 points. Blood cortisol concentration at 8:00 am was normal (410.1+/-175.1 mmol/L) in majority of patients. Decreased concentration was only in four patients (122.4+/-15.5 mmol/L); one of these patients underwent heart transplantation. In the afternoon, blood cortisol concentration was insufficiently decreased (355.6+/-160.3 mmol/L); reaction to a physical stress was attenuated (Delta 92.9 mmol/L). Plasma NT-proBNP concentration was 2188.9+/-1852.2 pg/L; reaction to a physical stress was diminished (Delta 490.3 pg/L). All patients with NYHA class III-IV heart failure complained of daily chronic fatigue. Insufficiently decreased blood cortisol concentration in the afternoon showed that in the presence of chronic fatigue in long-term cardiovascular organic disease, disorder of a hypothalamus-pituitary-adrenal axis is involved.

  12. Carrier-envelope-phase stabilized terawatt class laser at 1 kHz with a wavelength tunable option

    DOE PAGES

    Langdon, Benjamin; Garlick, Jonathan; Ren, Xiaoming; ...

    2015-02-12

    We demonstrate a chirped-pulse-amplified Ti:Sapphire laser system operating at 1 kHz, with 20 mJ pulse energy, 26 femtosecond pulse duration (0.77 terawatt), and excellent long term carrier-envelope-phase (CEP) stability. A new vibrational damping technique is implemented to significantly reduce vibrational noise on both the laser stretcher and compressor, thus enabling a single-shot CEP noise value of 250 mrad RMS over 1 hour and 300 mrad RMS over 9 hours. This is, to the best of our knowledge, the best long term CEP noise ever reported for any terawatt class laser. This laser is also used to pump a white-light-seeded opticalmore » parametric amplifier, producing 6 mJ of total energy in the signal and idler with 18 mJ of pumping energy. Due to preservation of the CEP in the white-light generated signal and passive CEP stability in the idler, this laser system promises synthesized laser pulses spanning multi-octaves of bandwidth at an unprecedented energy scale.« less

  13. Antimicrobial peptide inhibition of fungalysin proteases that target plant type 19 Family IV defense chitinases

    USDA-ARS?s Scientific Manuscript database

    Cereal crops and other plants produce secreted seed chitinases that reduce pathogenic infection, most likely by targeting the fungal chitinous cell wall. We have shown that corn (Zea mays) produces three GH family 19, plant class IV chitinases, that help in protecting the plant against Fusarium and ...

  14. Green laser pointers for visual astronomy: how much power is enough?

    PubMed

    Bará, Salvador; Robles, Marisol; Tejelo, Isabel; Marzoa, Ramón I; González, Héctor

    2010-02-01

    Green laser pointers with output powers in the tens to hundreds of milliwatt (mW) range, clearly exceeding the limiting 5 mW of American National Standards Institute class 3a (International Electrotechnical Commission class 3R), are now easily available in the global market. They are increasingly being used in public sky observations and other nighttime outreach activities by educators and science communicators in countries where their use is not well regulated, despite the fact that such high power levels may represent a potential threat to visual health. The purpose of this study was to determine the output power reasonably required to perform satisfactorily this kind of activities. Twenty-three observers were asked to vary continuously the output power of a green laser source (wavelength 532 nm) until clearly seeing the laser beam propagating skyward through the atmosphere in a heavily light-polluted urban setting. Measurements were conducted with observers of a wide range of ages (9 to 56 years), refractions (spherical equivalents -8.50 to +1.50 diopters), and previous expertise in using lasers as pointing devices outdoors (from no experience to professional astronomers). Two measurement runs were made in different nights under different meteorological conditions. The output power chosen by observers in the first run (11 observers) averaged to 1.84 mW (+/-0.68 mW, 1 SD). The second run (17 observers) averaged to 2.91 mW (+/-1.54 mW). The global average was 2.38 mW (+/-1.30 mW). Only one observer scored 5.6 mW, just above the class 3a limit. The power chosen by the remaining 22 observers ranged from 1.37 to 3.53 mW. Green laser pointers with output powers below 5 mW (laser classes American National Standards Institute 3a or International Electrotechnical Commission 3R) appear to be sufficient for use in educational nighttime outdoors activities, providing enough bright beams at reasonable safety levels.

  15. chs-4, a class IV chitin synthase gene from Neurospora crassa.

    PubMed

    Din, A B; Specht, C A; Robbins, P W; Yarden, O

    1996-02-05

    In Saccharomyces cerevisiae, most of the cellular chitin is produced by chitin synthase III, which requires the product encoded by the CSD2/CAL1/DIT101/KT12 gene. We have identified, isolated and structurally characterized as CSD2/CAL1/DIT101/KT12 homologue in the filamentous ascomycete Neurospora crassa and have used a "reverse genetics" approach to determine its role in vivo. The yeast gene was used as a heterologous probe for the isolation of a N. crassa gene(designated chs-4) encoding a polypeptide belonging to a class of chitin synthases which we have designated class IV. The predicted polypeptide encoded by this gene is highly similar to those of S. cerevisiae and Candida albicans. N. crassa strains in which chs-4 had been inactivated by the Repeat-Induced point mutation (RIP) process grew and developed in a normal manner under standard growth conditions. However, when grown in the presence of sorbose (a carbon source which induces morphological changes accompanied by elevated chitin content), chitin levels in the chs-4RIP strain were significantly lower than those observed in the wild type. We suggest that CHS4 may serve as an auxiliary enzyme in N. crassa and that, in contrast to yeasts, it is possible that filamentous fungi may have more than one class IV chitin synthase.

  16. Identification of branched-chain amino acid aminotransferases active towards (R)-(+)-1-phenylethylamine among PLP fold type IV transaminases.

    PubMed

    Bezsudnova, Ekaterina Yu; Dibrova, Daria V; Nikolaeva, Alena Yu; Rakitina, Tatiana V; Popov, Vladimir O

    2018-04-10

    New class IV transaminases with activity towards L-Leu, which is typical of branched-chain amino acid aminotransferases (BCAT), and with activity towards (R)-(+)-1-phenylethylamine ((R)-PEA), which is typical of (R)-selective (R)-amine:pyruvate transaminases, were identified by bioinformatics analysis, obtained in recombinant form, and analyzed. The values of catalytic activities in the reaction with L-Leu and (R)-PEA are comparable to those measured for characteristic transaminases with the corresponding specificity. Earlier, (R)-selective class IV transaminases were found to be active, apart from (R)-PEA, only with some other (R)-primary amines and D-amino acids. Sequences encoding new transaminases with mixed type of activity were found by searching for changes in the conserved motifs of sequences of BCAT by different bioinformatics tools. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Laser Ignition Device and Its Application to Forestry, Fire and Land Management

    Treesearch

    Michael D. Waterworth

    1987-01-01

    A laser ignition device for controlled burning of forest logging slash has been developed and successfully tested. The device, which uses a kilowatt class carbon dioxide laser, operates at distances of 50 to 1500 meters. Acquisition and focus control are achieved by the use of a laser rangefinder and acquisition telescope. Additional uses for the device include back...

  18. Evaluation, Feasibility, and Design of a Three-Wavelength Infrared Atmospheric Aerosol Extinctiometer.

    DTIC Science & Technology

    1980-09-02

    laser or searchlight measurements . The study program consisted of three basic tasks: (1) a review of existing techniques for measuring aerosol extinction ...to aerosol extinction along a path can be deduced. Solutions to this problcaii fall into several classes. One class of solutions invoLves measuring ...employed such a windowless system to measure the absorption of an artificial aerosol consisting of quartz particles, using a CO 2 laser in the

  19. Nonlinear Spectroscopy.

    DTIC Science & Technology

    1985-03-20

    Finally, the (linear) .response of a Fabry - Perot cavity to a phase modulated light wave is considered because of its relevance to phase locking a laser...prepared and therefore doesn’t contribute. This effect provides the remaining factor of two. IV. FABRY - PEROT We now calculate the response of a plane...mirror Fabry - Perot cavity to a phase-modulated laser beam. This linear problem, which contrasts with the nonlinear atomic case, is the basis of an

  20. Characterization of a Ho:Tm:Cr:YAG laser with a Cr:GSAG laser as pumping source

    NASA Technical Reports Server (NTRS)

    Henderson, George W.

    1989-01-01

    Rare earth lasers were in existance since the first laser was developed. The primary lasing elements for the class of lasers in the infrared was neodymium and chromium. However, the need for eye safe lasers in the mid-infrared range has prompted an enormous amount of research to the use of other elements. Holmium was investigated extensively as the source of infrared radiation for atmospheric research as well as medical research. The results and procedure are briefly discussed.

  1. Treatments for traumatic brain injury with emphasis on transcranial near-infrared laser phototherapy

    PubMed Central

    Morries, Larry D; Cassano, Paolo; Henderson, Theodore A

    2015-01-01

    Traumatic brain injury (TBI) is a growing health concern affecting civilians and military personnel. In this review, treatments for the chronic TBI patient are discussed, including pharmaceuticals, nutraceuticals, cognitive therapy, and hyperbaric oxygen therapy. All available literature suggests a marginal benefit with prolonged treatment courses. An emerging modality of treatment is near-infrared (NIR) light, which has benefit in animal models of stroke, spinal cord injury, optic nerve injury, and TBI, and in human trials for stroke and TBI. The extant literature is confounded by variable degrees of efficacy and a bewildering array of treatment parameters. Some data indicate that diodes emitting low-level NIR energy often have failed to demonstrate therapeutic efficacy, perhaps due to failing to deliver sufficient radiant energy to the necessary depth. As part of this review, we present a retrospective case series using high-power NIR laser phototherapy with a Class IV laser to treat TBI. We demonstrate greater clinical efficacy with higher fluence, in contrast to the bimodal model of efficacy previously proposed. In ten patients with chronic TBI (average time since injury 9.3 years) given ten treatments over the course of 2 months using a high-power NIR laser (13.2 W/0.89 cm2 at 810 nm or 9 W/0.89 cm2 at 810 nm and 980 nm), symptoms of headache, sleep disturbance, cognition, mood dysregulation, anxiety, and irritability improved. Symptoms were monitored by depression scales and a novel patient diary system specifically designed for this study. NIR light in the power range of 10–15 W at 810 nm and 980 nm can safely and effectively treat chronic symptoms of TBI. The clinical benefit and effects of infrared phototherapy on mitochondrial function and secondary molecular events are discussed in the context of adequate radiant energy penetration. PMID:26347062

  2. Outcome of bipolar electrocoagulation with lesionectomy in the treatment of epilepsy involving eloquent areas.

    PubMed

    Zhai, Feng; Zhou, Jian; Li, Tianfu; Cui, Zhiqiang; Luan, Guoming

    2015-01-01

    We have demonstrated previously that bipolar electrocoagulation on functional cortex (BCFC) is a safe and effective approach for epilepsy involving eloquent areas. Here, we report the results of BCFC with lesionectomy for patients with epileptogenic foci partially overlapping eloquent areas. Forty patients who had been treated with lesionectomy with BCFC were retrospectively reviewed with regard to seizure outcome and neurological deficits. Ten similar patients who had received lesionectomy with multiple subpial transections (MST) were examined as a control group. In the lesionectomy group with BCFC, Engel class I was achieved in 18 (45%) patients, class II in 8 (20%) patients, class III in 8 (20%) patients and class IV in 6 (15%) patients. Five (12.5%) patients developed mild hemiparesis and 1 (2.5%) patient mild sensory dysphasia. In the lesionectomy group with MST, Engel class I was achieved in 3 (30%) patients, class II in 2 (20%) patients, class III in 3 (30%) patients and class IV in 2 (20%) patients. Two (20%) patients developed mild hemiparesis and 1 (10%) patient moderate hemiparesis. All these complications recovered within 1-12 months. Compared with MST, the outcome of BCFC with lesionectomy is similar. But since MST leads to mechanical injury, while BCFC causes thermal injury, the complications of BCFC seem less severe. © 2014 S. Karger AG, Basel.

  3. Heterogonous expression and characterization of a plant class IV chitinase from the pitcher of the carnivorous plant Nepenthes alata.

    PubMed

    Ishisaki, Kana; Honda, Yuji; Taniguchi, Hajime; Hatano, Naoya; Hamada, Tatsuro

    2012-03-01

    A class IV chitinase belonging to the glycoside hydrolase 19 family from Nepenthes alata (NaCHIT1) was expressed in Escherichia coli. The enzyme exhibited weak activity toward polymeric substrates and significant activity toward (GlcNAc)(n) [β-1,4-linked oligosaccharide of GlcNAc with a polymerization degree of n (n = 4-6)]. The enzyme hydrolyzed the third and fourth glycosidic linkages from the non-reducing end of (GlcNAc)(6). The pH optimum of the enzymatic reaction was 5.5 at 37°C. The optimal temperature for activity was 60°C in 50 mM sodium acetate buffer (pH 5.5). The anomeric form of the products indicated that it was an inverting enzyme. The k(cat)/K(m) of the (GlcNAc)(n) hydrolysis increased with an increase in the degree of polymerization. Amino acid sequence alignment analysis between NaCHIT1 and a class IV chitinase from a Picea abies (Norway spruce) suggested that the deletion of four loops likely led the enzyme to optimize the (GlcNAc)(n) hydrolytic reaction rather than the hydrolysis of polymeric substrates.

  4. Nanos-mediated repression of hid protects larval sensory neurons after a global switch in sensitivity to apoptotic signals

    PubMed Central

    Bhogal, Balpreet; Plaza-Jennings, Amara

    2016-01-01

    Dendritic arbor morphology is a key determinant of neuronal function. Once established, dendrite branching patterns must be maintained as the animal develops to ensure receptive field coverage. The translational repressors Nanos (Nos) and Pumilio (Pum) are required to maintain dendrite growth and branching of Drosophila larval class IV dendritic arborization (da) neurons, but their specific regulatory role remains unknown. We show that Nos-Pum-mediated repression of the pro-apoptotic gene head involution defective (hid) is required to maintain a balance of dendritic growth and retraction in class IV da neurons and that upregulation of hid results in decreased branching because of an increase in caspase activity. The temporal requirement for nos correlates with an ecdysone-triggered switch in sensitivity to apoptotic stimuli that occurs during the mid-L3 transition. We find that hid is required during pupariation for caspase-dependent pruning of class IV da neurons and that Nos and Pum delay pruning. Together, these results suggest that Nos and Pum provide a crucial neuroprotective regulatory layer to ensure that neurons behave appropriately in response to developmental cues. PMID:27256879

  5. Nanos-mediated repression of hid protects larval sensory neurons after a global switch in sensitivity to apoptotic signals.

    PubMed

    Bhogal, Balpreet; Plaza-Jennings, Amara; Gavis, Elizabeth R

    2016-06-15

    Dendritic arbor morphology is a key determinant of neuronal function. Once established, dendrite branching patterns must be maintained as the animal develops to ensure receptive field coverage. The translational repressors Nanos (Nos) and Pumilio (Pum) are required to maintain dendrite growth and branching of Drosophila larval class IV dendritic arborization (da) neurons, but their specific regulatory role remains unknown. We show that Nos-Pum-mediated repression of the pro-apoptotic gene head involution defective (hid) is required to maintain a balance of dendritic growth and retraction in class IV da neurons and that upregulation of hid results in decreased branching because of an increase in caspase activity. The temporal requirement for nos correlates with an ecdysone-triggered switch in sensitivity to apoptotic stimuli that occurs during the mid-L3 transition. We find that hid is required during pupariation for caspase-dependent pruning of class IV da neurons and that Nos and Pum delay pruning. Together, these results suggest that Nos and Pum provide a crucial neuroprotective regulatory layer to ensure that neurons behave appropriately in response to developmental cues. © 2016. Published by The Company of Biologists Ltd.

  6. In vitro characterization of the antibacterial spectrum of novel bacterial type II topoisomerase inhibitors of the aminobenzimidazole class.

    PubMed

    Mani, Nagraj; Gross, Christian H; Parsons, Jonathan D; Hanzelka, Brian; Müh, Ute; Mullin, Steve; Liao, Yusheng; Grillot, Anne-Laure; Stamos, Dean; Charifson, Paul S; Grossman, Trudy H

    2006-04-01

    Antibiotics with novel mechanisms of action are becoming increasingly important in the battle against bacterial resistance to all currently used classes of antibiotics. Bacterial DNA gyrase and topoisomerase IV (topoIV) are the familiar targets of fluoroquinolone and coumarin antibiotics. Here we present the characterization of two members of a new class of synthetic bacterial topoII ATPase inhibitors: VRT-125853 and VRT-752586. These aminobenzimidazole compounds were potent inhibitors of both DNA gyrase and topoIV and had excellent antibacterial activities against a wide spectrum of problematic pathogens responsible for both nosocomial and community-acquired infections, including staphylococci, streptococci, enterococci, and mycobacteria. Consistent with the novelty of their structures and mechanisms of action, antibacterial potency was unaffected by commonly encountered resistance phenotypes, including fluoroquinolone resistance. In time-kill assays, VRT-125853 and VRT-752586 were bactericidal against Staphylococcus aureus, Streptococcus pneumoniae, Enterococcus faecalis, and Haemophilus influenzae, causing 3-log reductions in viable cells within 24 h. Finally, similar to the fluoroquinolones, relatively low frequencies of spontaneous resistance to VRT-125853 and VRT-752586 were found, a property consistent with their in vitro dual-targeting activities.

  7. In Vitro Characterization of the Antibacterial Spectrum of Novel Bacterial Type II Topoisomerase Inhibitors of the Aminobenzimidazole Class

    PubMed Central

    Mani, Nagraj; Gross, Christian H.; Parsons, Jonathan D.; Hanzelka, Brian; Müh, Ute; Mullin, Steve; Liao, Yusheng; Grillot, Anne-Laure; Stamos, Dean; Charifson, Paul S.; Grossman, Trudy H.

    2006-01-01

    Antibiotics with novel mechanisms of action are becoming increasingly important in the battle against bacterial resistance to all currently used classes of antibiotics. Bacterial DNA gyrase and topoisomerase IV (topoIV) are the familiar targets of fluoroquinolone and coumarin antibiotics. Here we present the characterization of two members of a new class of synthetic bacterial topoII ATPase inhibitors: VRT-125853 and VRT-752586. These aminobenzimidazole compounds were potent inhibitors of both DNA gyrase and topoIV and had excellent antibacterial activities against a wide spectrum of problematic pathogens responsible for both nosocomial and community-acquired infections, including staphylococci, streptococci, enterococci, and mycobacteria. Consistent with the novelty of their structures and mechanisms of action, antibacterial potency was unaffected by commonly encountered resistance phenotypes, including fluoroquinolone resistance. In time-kill assays, VRT-125853 and VRT-752586 were bactericidal against Staphylococcus aureus, Streptococcus pneumoniae, Enterococcus faecalis, and Haemophilus influenzae, causing 3-log reductions in viable cells within 24 h. Finally, similar to the fluoroquinolones, relatively low frequencies of spontaneous resistance to VRT-125853 and VRT-752586 were found, a property consistent with their in vitro dual-targeting activities. PMID:16569833

  8. Laser Diagnostics for combustion temperature and species measurements

    NASA Technical Reports Server (NTRS)

    Eckbreth, Alan C.

    1988-01-01

    Laser optical diagnostic techniques for the measurement of combustion gaseous-phase temperatures and, or species concentrations are discussed. The techniques fall into two classes: incoherent (Rayleigh scattering, spontaneous Raman scattering, laser induced fluorescence spectroscopy) and coherent (coherent anti-Stokes Raman spectroscopy). The advantages, disadvantages and applicability of each method are outlined.

  9. Athermal laser design.

    PubMed

    Bovington, Jock; Srinivasan, Sudharsanan; Bowers, John E

    2014-08-11

    This paper discusses circuit based and waveguide based athermalization schemes and provides some design examples of athermalized lasers utilizing fully integrated athermal components as an alternative to power hungry thermo-electric controllers (TECs), off-chip wavelength lockers or monitors with lookup tables for tunable lasers. This class of solutions is important for uncooled transmitters on silicon.

  10. Tailoring Laser Propulsion for Future Applications in Space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckel, Hans-Albert; Scharring, Stefan

    Pulsed laser propulsion may turn out as a low cost alternative for the transportation of small payloads in future. In recent years DLR investigated this technology with the goal of cheaply launching small satellites into low earth orbit (LEO) with payload masses on the order of 5 to 10 kg. Since the required high power pulsed laser sources are yet not at the horizon, DLR focused on new applications based on available laser technology. Space-borne, i.e. in weightlessness, there exist a wide range of missions requiring small thrusters that can be propelled by laser power. This covers space logistic andmore » sample return missions as well as position keeping and attitude control of satellites.First, a report on the proof of concept of a remote controlled laser rocket with a thrust vector steering device integrated in a parabolic nozzle will be given. Second, the road from the previous ground-based flight experiments in earth's gravity using a 100-J class laser to flight experiments with a parabolic thruster in an artificial 2D-zero gravity on an air cushion table employing a 1-J class laser and, with even less energy, new investigations in the field of laser micro propulsion will be reviewed.« less

  11. 21 CFR 872.1745 - Laser fluorescence caries detection device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... fluorescence detector housed in a dental handpiece, and a control console that performs device calibration, as...) Properly sterilize the emitter-detector handpick before each use, and (iv) Properly maintain and handle the...

  12. 21 CFR 872.1745 - Laser fluorescence caries detection device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... fluorescence detector housed in a dental handpiece, and a control console that performs device calibration, as...) Properly sterilize the emitter-detector handpick before each use, and (iv) Properly maintain and handle the...

  13. Screening and staging for non-small cell lung cancer by serum laser Raman spectroscopy.

    PubMed

    Wang, Hong; Zhang, Shaohong; Wan, Limei; Sun, Hong; Tan, Jie; Su, Qiucheng

    2018-08-05

    Lung cancer is the leading cause of cancer-related death worldwide. Current clinical screening methods to detect lung cancer are expensive and associated with many complications. Raman spectroscopy is a spectroscopic technique that offers a convenient method to gain molecular information about biological samples. In this study, we measured the serum Raman spectral intensity of healthy volunteers and patients with different stages of non-small cell lung cancer. The purpose of this study was to evaluate the application of serum laser Raman spectroscopy as a low cost alternative method in the screening and staging of non-small cell lung cancer (NSCLC). The Raman spectra of the sera of peripheral venous blood were measured with a LabRAM HR 800 confocal Micro Raman spectrometer for individuals from five groups including 14 healthy volunteers (control group), 23 patients with stage I NSCLC (stage I group), 24 patients with stage II NSCLC (stage II group), 19 patients with stage III NSCLC (stage III group), 11 patients with stage IV NSCLC (stage IV group). Each serum sample was measured 3 times at different spots and the average spectra represented the signal of Raman spectra in each case. The Raman spectrum signal data of the five groups were statistically analyzed by analysis of variance (ANOVA), principal component analysis (PCA), linear discriminant analysis (LDA), and cross-validation. Raman spectral intensity was sequentially reduced in serum samples from control group, stage I group, stage II group and stage III/IV group. The strongest peak intensity was observed in the control group, and the weakest one was found in the stage III/IV group at bands of 848 cm -1 , 999 cm -1 , 1152 cm -1 , 1446 cm -1 and 1658 cm -1 (P < 0.05). Linear discriminant analysis showed that the sensitivity to identify healthy people, stage I, stage II, and stage III/IV NSCLC was 86%, 65%, 75%, and 87%, respectively; the specificity was 95%, 94%, 88%, and 93%, respectively; and the overall accuracy rate was 92% (71/77). The laser Raman spectroscopy can effectively identify patients with stage I, stage II or stage III/IV Non-Small Cell Lung cancer using patient serum samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Printed-Circuit-Board Soldering Training for Group IV Personnel.

    ERIC Educational Resources Information Center

    Hooprich, E. A.; Matlock, E. W.

    As part of a larger program to determine which Navy skills can be learned by lower aptitude personnel, and which methods and techniques would be most effective, an experimental course in printed circuit board soldering was given to 186 Group IV students in 13 classes. Two different training approaches--one stressing instructor guidance and the…

  15. Spectral characteristics of caries-related autofluorescence spectra and their use for diagnosis of caries stage

    NASA Astrophysics Data System (ADS)

    Son, Sung-Ae; Jung, Kyeong-Hoon; Ko, Ching-Chang; Kwon, Yong Hoon

    2016-01-01

    The purpose of the present study was to identify factors useful for diagnosis of the caries stage from laser-induced autofluorescence (AF) spectra. Affected teeth were accurately staged and allocated to four groups: sound, stage II, stage III, or stage IV. A 405-nm laser was used to produce AF spectra. The spectrum factors analyzed were spectrum slope at 550 to 600 nm, spectral area from 500 and 590 nm, and intensity ratio of peaks 625 and 667 nm (625/667 nm). DIAGNOdent was used as control measurement. AF spectra of sound teeth had a peak near 500 nm followed by a smooth decline to 800 nm. As caries progressed, some specimens in stages II to IV showed one or two peak(s) near 625 and 667 nm. Slopes at 550 to 600 nm and areas under the curve at 500 to 590 nm were significantly different (p<0.001) for each stage. Two-peak ratios were also significantly different (p<0.001) except for stage III and stage IV. DIAGNOdent readings for sound and stage II and stage III and IV were not significantly different. Among the studied factors, the spectrum slope at 550 to 600 nm and area under curve at 500 to 590 nm could be useful treatment decision-making tools for carious lesions.

  16. Apraclonidine Ophthalmic

    MedlinePlus

    ... the eye during and after certain types of laser eye surgery. Apraclonidine is in a class of medications called ... eye that is being treated 1 hour before laser eye surgery and again immediately after the surgery. If you ...

  17. Fabrication of 100 A class, 1 m long coated conductor tapes by metal organic chemical vapor deposition and pulsed laser deposition

    NASA Astrophysics Data System (ADS)

    Selvamanickam, V.; Lee, H. G.; Li, Y.; Xiong, X.; Qiao, Y.; Reeves, J.; Xie, Y.; Knoll, A.; Lenseth, K.

    2003-10-01

    SuperPower has been scaling up YBa 2Cu 3O x-based second-generation superconducting tapes by techniques such as pulsed laser deposition (PLD) using industrial laser and metal organic chemical vapor deposition (MOCVD). Both techniques offer advantage of high deposition rates, which is important for high throughput. Using highly-polished substrates produced in a reel-to-reel polishing facility and buffer layers deposited in a pilot ion beam assisted deposition facility, meter-long second-generation high temperature superconductor tapes have been produced. 100 A class, meter-long coated conductor tapes have been reproducibly demonstrated in this work by both MOCVD and PLD. The best results to date are 148 A over 1.06 m by MOCVD and 135 A over 1.1 m by PLD using industrial laser.

  18. Microleakage in Class V cavities with self-etching adhesive system and conventional rotatory or laser Er,Cr:YSGG

    PubMed Central

    Arnabat, J; España-Tost, T

    2012-01-01

    Objective: To analyse microleakage in Class V cavity preparation with Er;Cr:YSGG at different parameters using a self-etching adhesive system. Background: Several studies reported microleakage around composite restorations when cavity preparation is done or treated by Er;Cr:YSGG laser. We want to compare different energy densities in order to obtain the best parameters, when using a self-etching adhesive system. Methods: A class V preparations was performed in 120 samples of human teeth were divided in 3 groups: (1) Preparation using the burr. (2) Er;Cr:YSGG laser preparation with high energy 4W, 30 Hz, 50% Water 50% Air and (3) Er;Cr:YSGG laser preparation lower energy 1.5 W, 30 Hz, 30% Water 30% Air. All the samples were restored with self-etching adhesive system and hybrid composite. Thermocycling (5000 cycles) and immersed in 0.5% fuchsin. The restorations were sectioned and evaluated the microleakage with a stereomicroscope. Results: Lower energy laser used for preparation showed significant differences in enamel and dentin. To group 3, the microleakage in the enamel was less, whilst the group 1, treated with the turbine, showed less microleakage at dentin level. Group 2 showed the highest microleakage at dentin/cement level. Conclusion: Burr preparation gives the lowest microleakage at cement/dentin level, whilst Er;Cr:YSGG laser at lower power has the low energy obtains lowest microleakage at enamel. On the contrary high-energy settings produce inferior results in terms of microleakage. PMID:24511195

  19. 19 CFR Appendix to Part 146 - Guidelines for Determining Producibility and Relative Values for Oil Refinery Zones

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... × .20). Likewise, the class IV crude oil could produce aviation gasoline in an amount up to 8,500 pounds... Class III PF Crude 35,000 24,500 31,850 14,000 31,150 10,150 Class III D Crude 20,000 14,000 18,200 8,000 17,800 5,800 Class III NPF Crude 20,000 14,000 18,200 8,000 17,800 5,800 Feedstock factors are...

  20. 19 CFR Appendix to Part 146 - Guidelines for Determining Producibility and Relative Values for Oil Refinery Zones

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... × .20). Likewise, the class IV crude oil could produce aviation gasoline in an amount up to 8,500 pounds... Class III PF Crude 35,000 24,500 31,850 14,000 31,150 10,150 Class III D Crude 20,000 14,000 18,200 8,000 17,800 5,800 Class III NPF Crude 20,000 14,000 18,200 8,000 17,800 5,800 Feedstock factors are...

  1. 21 CFR 1040.10 - Laser products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... in paragraph (c)(2) of this section; and (3) The manufacturer of such a laser product, if... paragraphs (c), (d), and (e) of this section. (3) Aperture means any opening in the protective housing or... to define the shape of the area over which radiation is measured. (5) Class I laser product means any...

  2. Optical communication in free space

    NASA Technical Reports Server (NTRS)

    Plotkin, H. H.; Mcavoy, N.; Fitzmaurice, M. W.

    1974-01-01

    Two classes of laser communication systems for handling very high data rates across inter-satellite distances are considered that provide for high antenna gains, wide modulation bandwidths, and optical receiver sensitivities. System design considerations are based upon the carbon dioxide laser modulation to accommodate digital or analog information, and the neodymium doped YAG laser pulse for digital modulation.

  3. 76 FR 60463 - 36(b)(1) Arms Sales Notification

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-29

    ...; Dual Mode/Global Positioning System Laser-Guided Bombs (16 GBU-10 Enhanced PAVEWAY II or GBU-56 Laser... Munitions (JDAMs) kits; 80 GBU-38 JDAM kits; Dual Mode/Global Positioning System Laser-Guided Bombs (16 GBU... class cluster bomb munition containing sensor fused sub-munitions that are designed to attack and defeat...

  4. Biological Effects of Laser Radiation. Volume IV. Optical Second Harmonic Generation in Biological Tissues.

    DTIC Science & Technology

    1978-10-17

    characteristics for optical second- harmonic generation. The collage component of conective tissue may be the principal site for the observed harmonic...Generation in Tissue ; Second Harmonic Generation in Collage; Glutathione, 5MB; Mechanisms; Conversion Efficiency; Significance of order UL AIM UY#m~wmev...sclera, and skin on 694 im. Q-switched ruby laser irradiation. A possible source of this second-harmonic generation was tissue collagen; because of

  5. BCI Competition IV – Data Set I: Learning Discriminative Patterns for Self-Paced EEG-Based Motor Imagery Detection

    PubMed Central

    Zhang, Haihong; Guan, Cuntai; Ang, Kai Keng; Wang, Chuanchu

    2012-01-01

    Detecting motor imagery activities versus non-control in brain signals is the basis of self-paced brain-computer interfaces (BCIs), but also poses a considerable challenge to signal processing due to the complex and non-stationary characteristics of motor imagery as well as non-control. This paper presents a self-paced BCI based on a robust learning mechanism that extracts and selects spatio-spectral features for differentiating multiple EEG classes. It also employs a non-linear regression and post-processing technique for predicting the time-series of class labels from the spatio-spectral features. The method was validated in the BCI Competition IV on Dataset I where it produced the lowest prediction error of class labels continuously. This report also presents and discusses analysis of the method using the competition data set. PMID:22347153

  6. Self-organized perturbations enhance class IV behavior and 1/f power spectrum in elementary cellular automata.

    PubMed

    Nakajima, Kohei; Haruna, Taichi

    2011-09-01

    In this paper, we propose a new class of cellular automata based on the modification of its state space. It is introduced to model a computation which is exposed to an environment. We formalized the computation as extension and projection processes of its state space and resulting misidentifications of the state. This is motivated to embed the role of an environment into the system itself, which naturally induces self-organized internal perturbations rather than the usual external perturbations. Implementing this structure into the elementary cellular automata, we characterized its effect by means of input entropy and power spectral analysis. As a result, the cellular automata with this structure showed robust class IV behavior and a 1/f power spectrum in a wide range of rule space comparative to the notion of the edge of chaos. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Performance comparison of supersonic ejectors with different motive gas injection schemes applicable for flowing medium gas laser

    NASA Astrophysics Data System (ADS)

    Singhal, G.; Subbarao, P. M. V.; Mainuddin; Tyagi, R. K.; Dawar, A. L.

    2017-05-01

    A class of flowing medium gas lasers with low generator pressures employ supersonic flows with low cavity pressure and are primarily categorized as high throughput systems capable of being scaled up to MW class. These include; Chemical Oxygen Iodine Laser (COIL) and Hydrogen (Deuterium) Fluoride (HF/DF). The practicability of such laser systems for various applications is enhanced by exhausting the effluents directly to ambient atmosphere. Consequently, ejector based pressure recovery forms a potent configuration for open cycle operation. Conventionally these gas laser systems require at least two ejector stages with low pressure stage being more critical, since it directly entrains the laser media, and the ensuing perturbation of cavity flow, if any, may affect laser operation. Hence, the choice of plausible motive gas injection schemes viz., peripheral or central is a fluid dynamic issue of interest, and a parametric experimental performance comparison would be beneficial. Thus, the focus is to experimentally characterize the effect of variation in motive gas supply pressure, entrainment ratio, back pressure conditions, nozzle injection position operated together with a COIL device and discern the reasons for the behavior.

  8. Laser action benzimidazoles in various aggregate states

    NASA Astrophysics Data System (ADS)

    Gruzinskii, V. V.; Degtiarenko, K. M.; Shalaev, V. K.; Kopylova, T. N.; Verkhovskii, V. S.; Tarasenko, V. F.; Melchenko, S. V.

    1983-04-01

    Lasing has been obtained in solutions of benzimidazole (Bi) derivatives: 2-phenyl-Bi (with the band maximum lambda-r-max = 341-347 nm), 2-n-tolyl-Bi (344 nm), and 2-(4'-biphenilyl) Bi (366-374 nm). It is found that compounds of this class provide a basis for laser radiation covering a wide region of the spectrum. Lasing has been obtained on the vapors of 2-(4'-biphenilyl) Bi (361.2 nm) and 2-(n-tolyl) Bi (336.5 nm) with a pentane stabilizer of the excited states. High volatility, photostability, and lasing in wide ranges of concentration determine the efficiency of using this new class of compounds (chain arylbenzimidazoles) in lasers using the vapors of complex molecules.

  9. Assessment and Mitigation of Radiation, EMP, Debris & Shrapnel Impacts at Megajoule-Class Laser Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eder, D C; Anderson, R W; Bailey, D S

    2009-10-05

    The generation of neutron/gamma radiation, electromagnetic pulses (EMP), debris and shrapnel at mega-Joule class laser facilities (NIF and LMJ) impacts experiments conducted at these facilities. The complex 3D numerical codes used to assess these impacts range from an established code that required minor modifications (MCNP - calculates neutron and gamma radiation levels in complex geometries), through a code that required significant modifications to treat new phenomena (EMSolve - calculates EMP from electrons escaping from laser targets), to a new code, ALE-AMR, that is being developed through a joint collaboration between LLNL, CEA, and UC (UCSD, UCLA, and LBL) for debrismore » and shrapnel modelling.« less

  10. Free-space laser communication technologies IV; Proceedings of the 4th Conference, Los Angeles, CA, Jan. 23, 24, 1992

    NASA Technical Reports Server (NTRS)

    Begley, David L. (Editor); Seery, Bernard D. (Editor)

    1992-01-01

    Papers included in this volume are grouped under topics of receivers; laser transmitters; components; system analysis, performance, and applications; and beam control (pointing, acquisition, and tracking). Papers are presented on an experimental determination of power penalty contributions in an optical Costas-type phase-locked loop receiver, a resonant laser receiver for free-space laser communications, a simple low-loss technique for frequency-locking lasers, direct phase modulation of laser diodes, and a silex beacon. Particular attention is given to experimental results on an optical array antenna for nonmechanical beam steering, a potassium Faraday anomalous dispersion optical filter, a 100-Mbps resonant cavity phase modulator for coherent optical communications, a numerical simulation of a 325-Mbit/s QPPM optical communication system, design options for an optical multiple-access data relay terminal, CCD-based optical tracking loop design trades, and an analysis of a spatial-tracking subsystem for optical communications.

  11. Provision of Atraumatic Restorative Treatment (ART) restorations to Chinese pre-school children--a 30-month evaluation.

    PubMed

    Lo, E C; Holmgren, C J

    2001-01-01

    The objectives of this study were: to provide restorations using the ART approach to pre-school children in Southern China in a kindergarten environment, using a high-strength glass-ionomer restorative material; to assess the acceptability of this approach and to evaluate on a longitudinal basis the restorations placed. A total of 170 ART restorations were placed in 95 children, aged 5.1 +/- 0.7 years, by seven final-year dental students using standard ART procedures and hand instruments. The restorations were evaluated every six months thereafter by two calibrated independent examiners using explorers and mouth-mirrors. 93% of the children reported that they did not feel pain during treatment and 86% were willing to receive ART restorations again. The cumulative 12- and 30-month survival rates of Class I restorations were 91% and 79%, respectively. The corresponding figures for Class V restorations were 79% and 70%, while those for Class II restorations were 75% and 51%. The failure rates of Class III and IV restorations were high with more than half of them scored as missing within the first year. The ART approach was shown to be acceptable to Chinese pre-school children for providing restorative dental care outside the traditional clinical setting. The success rates were high for Class I and V restorations in primary teeth, modest for Class II, and low for Class III and IV restorations.

  12. Generation conditions of CW Diode Laser Sustained Plasma

    NASA Astrophysics Data System (ADS)

    Nishimoto, Koji; Matsui, Makoto; Ono, Takahiro

    2016-09-01

    Laser sustained plasma was generated using 1 kW class continuous wave diode laser. The laser beam was focused on the seed plasma generated by arc discharge in 1 MPa xenon lamp. The diode laser has advantages of high energy conversion efficiency of 80%, ease of maintenance, compact size and availability of conventional quartz based optics. Therefore, it has a prospect of further development compared with conventional CO2 laser. In this study, variation of the plasma shape caused by laser power is observed and also temperature distribution in the direction of plasma radius is measured by optical emission spectroscopy.

  13. A laser-powered hydrokinetic system for caries removal and cavity preparation.

    PubMed

    Hadley, J; Young, D A; Eversole, L R; Gornbein, J A

    2000-06-01

    Laser systems have been developed for the cutting of dental hard tissues. The erbium, chromium:yttrium-scandium-gallium-garnet, or Er,Cr:YSGG, laser system used in conjunction with an air-water spray has been shown to be efficacious in vitro for cavity preparation. The authors randomly selected subjects for cavity preparation with conventional air turbine/bur dental surgery or an Er,Cr:YSGG laser-powered system using a split-mouth design. They prepared Class I, III and V cavities, placed resin restorations and evaluated subjects on the day of the procedure and 30 days and six months postoperatively for pulp vitality, recurrent caries, pain and discomfort, and restoration retention. Sixty-seven subjects completed the study. There were no statistical differences between the two treatment groups for the parameters measured with one exception; there was a statistically significant decrease in discomfort levels for the laser system at the time of cavity preparation for subjects who declined to receive local anesthetic. The Er,Cr:YSGG laser system is effective for preparation of Class I, III and V cavities and resin restorations are retained by lased tooth surfaces. Hard-tissue cutting lasers are being introduced for use in operative dentistry. In this study, an Er,Cr:YSGG laser has been shown to be effective for cavity preparation and restoration replacement.

  14. Class-A mode-locked lasers: Fundamental solutions

    NASA Astrophysics Data System (ADS)

    Kovalev, Anton V.; Viktorov, Evgeny A.

    2017-11-01

    We consider a delay differential equation (DDE) model for mode-locked operation in class-A semiconductor lasers containing both gain and absorber sections. The material processes are adiabatically eliminated as these are considered fast in comparison to the delay time for a long cavity device. We determine the steady states and analyze their bifurcations using DDE-BIFTOOL [Engelborghs et al., ACM Trans. Math. Software 28, 1 (2002)]. Multiple forms of coexistence, transformation, and hysteretic behavior of stable steady states and fundamental periodic regimes are discussed in bifurcation diagrams.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biedermann, G. W.; McGuinness, H. J.; Rakholia, A. V.

    Here, we demonstrate matter-wave interference in a warm vapor of rubidium atoms. Established approaches to light-pulse atom interferometry rely on laser cooling to concentrate a large ensemble of atoms into a velocity class resonant with the atom optical light pulse. In our experiment, we show that clear interference signals may be obtained without laser cooling. This effect relies on the Doppler selectivity of the atom interferometer resonance. Lastly, this interferometer may be configured to measure accelerations, and we demonstrate that multiple interferometers may be operated simultaneously by addressing multiple velocity classes.

  16. Army AL&T, April-June 2008

    DTIC Science & Technology

    2008-06-01

    IR )/laser designator (LD)/laser range finder (LRF) sensor. The Class I UAS consists of a Class I UAV, a cen- tralized controller and a minimal set...utility of a backpackable, affordable, easy-to- operate and responsive reconnais- sance and surveillance system through experimentation. • Use EO/ IR ...ARMY AL&T 33APRIL - JUNE 2008 • “The IR sensor pinpointed the enemy even after the sun went down. We could have really used this in Iraq.” • “The UAV

  17. Primary biliary cirrhosis degree assessment by acoustic radiation force impulse imaging and hepatic fibrosis indicators.

    PubMed

    Zhang, Hai-Chun; Hu, Rong-Fei; Zhu, Ting; Tong, Ling; Zhang, Qiu-Qin

    2016-06-14

    To evaluate the assessment of primary biliary cirrhosis degree by acoustic radiation force impulse imaging (ARFI) and hepatic fibrosis indicators. One hundred and twenty patients who developed liver cirrhosis secondary to primary biliary cirrhosis were selected as the observation group, with the degree of patient liver cirrhosis graded by Child-Pugh (CP) score. Sixty healthy individuals were selected as the control group. The four indicators of hepatic fibrosis were detected in all research objects, including hyaluronic acid (HA), laminin (LN), type III collagen (PC III), and type IV collagen (IV-C). The liver parenchyma hardness value (LS) was then measured by ARFI technique. LS and the four indicators of liver fibrosis (HA, LN, PC III, and IV-C) were observed in different grade CP scores. The diagnostic value of LS and the four indicators of liver fibrosis in determining liver cirrhosis degree with PBC, whether used alone or in combination, were analyzed by receiver operating characteristic (ROC) curve. LS and the four indicators of liver fibrosis within the three classes (A, B, and C) of CP scores in the observation group were higher than in the control group, with C class > B class > A class; the differences were statistically significant (P < 0.01). Although AUC values of LS within the three classes of CP scores were higher than in the four indicators of liver fibrosis, sensitivity and specificity were unstable. The ROC curves of LS combined with the four indicators of liver fibrosis revealed that: AUC and sensitivity in all indicators combined in the A class of CP score were higher than in LS alone, albeit with slightly decreased specificity; AUC and specificity in all indicators combined in the B class of CP score were higher than in LS alone, with unchanged sensitivity; AUC values (0.967), sensitivity (97.4%), and specificity (90%) of all indicators combined in the C class of CP score were higher than in LS alone (0.936, 92.1%, 83.3%). The diagnostic value of PBC cirrhosis degree in liver cirrhosis degree assessment by ARFI combined with the four indicators of serum liver fibrosis is of satisfactory effectiveness and has important clinical application value.

  18. Joint Tactical Information Distribution System (JTIDS). Class 3 Terminal Conceptual Study. Volume 4. Appendix A. Mission Profile Detail. Appendix B. Moments of the Decision Variable for preamble Detection

    DTIC Science & Technology

    1978-07-07

    i on CM . ’ oil ■ «) rH H O W CO rH 0) H H <: o I »d • •o H i ! • M CO X -H | i iQ M 4> m u...referred to Electronic Systems Division, Hanscom AFB, MA. Document partially illegible. AFGL ltr 15 May 1981 A I ’ ESD-ra-7B-l6l, Vol. IV V,^^7 -J...BEPORE COMPLETING FORM ESD-TR-78-161, Vol. IV 2 COVT ACCESSION NO I RCCIFICNT’S CATALOG NUMBCn 4. TITLE (mid Submit) JTIDS Class

  19. Relationship between renal pathology and the size of circulating immune complexes in patients with systemic lupus erythematosus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wener, M.H.; Mannik, M.; Schwartz, M.M.

    1987-03-01

    Sera from 35 patients with biopsy-proven diffuse proliferative (WHO class IV) or membranous (WHO class V) lupus nephritis were analyzed for the presence and size of circulating immune complexes. Elevations of the C1q solid-phase assay (C1qSP) for immune complexes were found in sera from all patients with diffuse proliferative nephritis, with a mean +/- 1 SEM of 166.8 +/- 42.0 micrograms/AHG-equivalents/ml serum, and in 71.4% of the patients with membranous nephritis (83.1 +/- 26.7, p = 0.06). Using the WHO criteria for subclasses of membranous lupus nephritis, we also designated renal biopsies as nonproliferative (WHO classes Va and Vb) ormore » proliferative (WHO classes IV and Vc). Employing the latter groupings, we observed significant differences between C1qSP results of patients with nonproliferative (30.3 +/- 8.8) and proliferative (172.8 +/- 36.8, p less than 0.001) lupus nephritis. These data suggest that the presence of C1q-binding material in serum is pathophysiologically related to proliferative glomerular lesions, and that levels of C1qSP binding reflect renal lesions in SLE patients. Sucrose density gradient ultracentrifugation was performed on each serum, and gradient fractions analyzed for C1qSP-binding and total IgG, using techniques to minimize losses of immune complexes. The predominant peak of C1qSP activity sedimented with the 6.6S monomeric IgG. The 6.6S C1q-binding IgG was increased only in 1 of 10 patients with membranous lupus nephritis without proliferative changes, and was elevated in 16 of 25 patients with proliferative lesions (WHO classes IV and Vc).« less

  20. 10-kW-class YAG laser application for heavy components

    NASA Astrophysics Data System (ADS)

    Ishide, Takashi; Tsubota, S.; Nayama, Michisuke; Shimokusu, Yoshiaki; Nagashima, Tadashi; Okimura, K.

    2000-02-01

    The authors have put the YAG laser of the kW class to practical use for repair welding of nuclear power plant steam generator heat exchanger tubes, all-position welding of pipings, etc. This paper describes following developed methods and systems of high power YAG laser processing. First, we apply the 6 kW to 10 kW YAG lasers for welding and cutting in heavy components. The beam guide systems we have used are optical fibers which core diameter is 0.6 mm to 0.8 mm and its length is 200 m as standard one. Using these system, we can get the 1 pass penetration of 15 mm to 20 mm and multi pass welding for more thick plates. Cutting of 100 mm thickness plate data also described for dismantling of nuclear power plants. In these systems we carried out the in-process monitoring by using CCD camera image processing and monitoring fiber which placed coaxial to the YAG optical lens system. In- process monitoring by the monitoring fiber, we measured the light intensity from welding area. Further, we have developed new hybrid welding with the TIG electrode at the center of lens for high power. The hybrid welding with TIG-YAG system aims lightening of welding groove allowances and welding of high quality. Through these techniques we have applied 7 kW class YAG laser for welding in the components of nuclear power plants.

  1. Demonstration of the MPV at Former Waikoloa Maneuver Area in Hawaii: UXO Characterization in Challenging Survey Environments Using the MPV

    DTIC Science & Technology

    2015-10-01

    Hawaii HASP Health and Safety Plan IDA Institute for Defense Analyses IVS Instrument Verification Strip m Meter mm Millimeter MPV Man Portable...the ArcSecond laser ranger was impractical due to the requirement to maintain line-of-sight for three rovers and tedious calibration. The SERDP...within 0.1m spacing and 99% within 0.15 m Repeatability of Instrument Verification Strip (IVS) survey   Amplitude of EM anomaly Amplitude of

  2. Comparative study between laser and conventional techniques for class V cavity preparation in gamma-irradiated teeth (in vitro study).

    PubMed

    Rasmy, Amr H M; Harhash, Tarek A; Ghali, Rami M S; El Maghraby, Eman M F; El Rouby, Dalia H

    2017-01-01

    The purpose of this study was to compare laser with conventional techniques in class V cavity preparation in gamma-irradiated teeth. Forty extracted human teeth with no carious lesions were used for this study and were divided into two main groups: Group I (n = 20) was not subjected to gamma radiation (control) and Group II (n=20) was subjected to gamma radiation of 60 Gray. Standard class V preparation was performed in buccal and lingual sides of each tooth in both groups. Buccal surfaces were prepared by the Er,Cr:YSGG laser (Waterlase iPlus) 2780 nm, using the gold handpiece with MZ10 Tip in non-contact and the "H" mode, following parameters of cavity preparation - power 6 W, frequency 50 Hz, 90% water and 70% air, then shifting to surface treatment laser parameters - power 4.5 W, frequency 50 Hz, 80% water and 50% air. Lingual surfaces were prepared by the conventional high-speed turbine using round diamond bur. Teeth were then sectioned mesio-distally, resulting in 80 specimens: 40 of which were buccal laser-treated (20 control and 20 gamma-irradiated specimens) and 40 were lingual conventional high-speed bur specimens (20 control and 20 gamma-irradiated specimens). Microleakage analysis revealed higher scores in both gamma groups compared with control groups. Chi-square test revealed no significant difference between both control groups and gamma groups (p=1, 0.819, respectively). A significant difference was revealed between all 4 groups (p=0.00018). Both laser and conventional high-speed turbine bur show good bond strength in control (non-gamma) group, while microleakage is evident in gamma group, indicating that gamma radiation had a dramatic negative effect on the bond strength in both laser and bur-treated teeth.

  3. Inflammatory mediators in chronic heart failure in North India.

    PubMed

    Fedacko, Jan; Singh, Ram B; Gupta, Aditya; Hristova, Krasimira; Toda, Eri; Kumar, Adarsh; Saxena, Manoj; Baby, Anjum; Singh, Ranjana; Toru, Takahashi; Wilson, Douglas W

    2014-08-01

    Recent evidence shows that pro-inflammatory cytokines may be important in the assessment of severity and prognosis in congestive heart failure (CHF). In the present study, we examine the association of cytokines with causes, grade and prognosis of CHF patients. Of 127 patients with CHF, 11 were excluded and the remaining 116 patients with different aetiologies of CHF, and 250 age- and sex-matched control subjects, were evaluated in this case study. Severity of disease based on the New York Heart Association (NYHA) standards, fell within functional classes II to IV. The diagnosis of HF was based on clinical manifestations as well as on echocardiographic heart enlargement. Cytokines were measured by chemiluminescence. Causes of death were assessed based on death certificates. Multivariate logistic regression analysis was used to determine the risk factors of heart failure. Echocardiographic ejection fraction was 39.1 +/- 8.2% (mean +/- SD) in the study group indicating class II-IV heart failure. Laboratory data showed increase in biomarkers of oxidative stress, among HF patients compared to healthy subjects. Pro-inflammatory cytokines; IL-6 and TNF-alpha were significantly higher among HF patients compared to healthy subjects. TNF-alpha and IL-6, showed significant increase among patients with CHF due to ischaemic heart disease and cardiomyopathy compared to levels among CHF patients with valvular heart disease and hypertensive heart diseases. The levels of the cytokines were significantly higher among patients with class III and IV heart failure and those who died, compared to patients with class II heart failure. Multivariate logistic regression analysis revealed that CAD, cardiomyopathy, and IL-6 were strongly associated--and low ejection fraction and TNF-alpha--weakly associated with HF. Of 116 patients, 20 (17.2%) died during a follow-up of two years, and the deaths were mainly among NYHA class III and IV patients in whom the cause of CHF was CAD (10.9%) and cardiomyopathy (6.9%) which had greater levels of cytokines. The findings indicated that pro-inflammatory cytokines may be important indicators of causes, severity of CHF and prognosis among these patients.

  4. From Dye Laser Factory to Portable Semiconductor Laser: Four Generations of Sodium Guide Star Lasers for Adaptive Optics in Astronomy and Space Situational Awareness

    NASA Astrophysics Data System (ADS)

    d'Orgeville, C.; Fetzer, G.

    This presentation recalls the history of sodium guide star laser systems used in astronomy and space situational awareness adaptive optics, analysing the impact that sodium laser technology evolution has had on routine telescope operations. While it would not be practical to describe every single sodium guide star laser system developed to date, it is possible to characterize their evolution in broad technology terms. The first generation of sodium lasers used dye laser technology to create the first sodium laser guide stars in Hawaii, California, and Spain in the late 1980's and 1990's. These experimental systems were turned into the first laser guide star facilities to equip medium-to-large diameter adaptive optics telescopes, opening a new era of LGS AO-enabled diffraction-limited imaging from the ground. Although they produced exciting scientific results, these laser guide star facilities were large, power-hungry and messy. In the USA, a second-generation of sodium lasers was developed in the 2000's that used cleaner, yet still large and complex, solid-state laser technology. These are the systems in routine operation at the 8-10m class astronomical telescopes and 4m-class satellite imaging facilities today. Meanwhile in Europe, a third generation of sodium lasers was being developed using inherently compact and efficient fiber laser technology, and resulting in the only commercially available sodium guide star laser system to date. Fiber-based sodium lasers will be deployed at two astronomical telescopes and at least one space debris tracking station this year. Although highly promising, these systems remain significantly expensive and they have yet to demonstrate high performance in the field. We are proposing to develop a fourth generation of sodium lasers: based on semiconductor technology, these lasers could provide the final solution to the problem of sodium laser guide star adaptive optics for all astronomy and space situational awareness applications.

  5. Novel use of non-ablative fractional photothermolysis for café-au-lait macules in darker skin types.

    PubMed

    Balaraman, Brundha; Ravanfar-Jordan, Parisa; Friedman, Paul M

    2017-01-01

    The removal of café-au-lait macules (CALMs) in patients with darker skin phototypes poses a significant challenge due to limited available therapeutic options and increased risk of adverse effects, including permanent scarring and further dyspigmentation. Herein, we demonstrate the novel use of non-ablative fractional photothermolysis for the safe removal of CALMs in individuals with Fitzpatrick skin type (FST) IV-V. Retrospective analysis of four patients (FST IV-V) with CALMs revealed that three of these patients had greater than 50% clearance after multiple treatment sessions with the non-ablative fractional 1,550-nm erbium-doped fiber laser. This report demonstrates the utility and safety of non-ablative fractional resurfacing in the treatment of CALMs in darker skin phototypes. Lasers Surg. Med. 49:84-87, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Current Status of Fractional Laser Resurfacing.

    PubMed

    Carniol, Paul J; Hamilton, Mark M; Carniol, Eric T

    2015-01-01

    Fractional lasers were first developed based on observations of lasers designed for hair transplantation. In 2007, ablative fractional laser resurfacing was introduced. The fractionation allowed deeper tissue penetration, leading to greater tissue contraction, collagen production and tissue remodeling. Since then, fractional erbium:YAG resurfacing lasers have also been introduced. These lasers have yielded excellent results in treating photoaging, acne scarring, and dyschromia. With the adjustment of microspot density, pulse duration, number of passes, and fluence, the surgeon can adjust the treatment effects. These lasers have allowed surgeons to treat patients with higher Fitzpatrick skin types (types IV to VI) and greater individualize treatments to various facial subunits. Immunohistochemical analysis has demonstrated remodeling effects of the tissues for several months, producing longer lasting results. Adjuvant treatments are also under investigation, including concomitant face-lift, product deposition, and platelet-rich plasma. Finally, there is a short recovery time from treatment with these lasers, allowing patients to resume regular activities more quickly. Although there is a relatively high safety profile for ablative fractionated lasers, surgeons should be aware of the limitations of specific treatments and the associated risks and complications.

  7. Study of Default Options in Advance Directives

    ClinicalTrials.gov

    2015-06-29

    COPD; Severe or Very Severe Airflow Obstruction and/or Receiving or Eligible to Receive Long-term Oxygen Therapy; Idiopathic Pulmonary Fibrosis; Other Interstitial Lung Disease Without Curative Therapy; Congestive Heart Failure; NYHA Class IV or NYHA Class III Plus 1 Hospitalization in the Past Year; Malignancy; Any Stage 3B or 4 Solid Tumor

  8. 78 FR 56732 - Submission of Information Collection Extensions Under the Paperwork Reduction Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-13

    ... Control Number 3141-0006; and (iv) issuance to tribes of certificates of self- regulation for Class II... the Commission for a certificate of self-regulation for its Class II gaming operation(s). The... to issue the certificate of self- regulation. Once a certificate of self-regulation has been issued...

  9. 78 FR 40766 - Renewals of Information Collections Under the Paperwork Reduction Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-08

    ... Control Number 3141-0006; and (iv) issuance to tribes of certificates of self-regulation for Class II.... Estimated Total Non-hour Cost Burden: $14,846,686. Title: Issuance of Certificates of Self-Regulation to... Commission for a certificate of self-regulation for its Class II gaming operation(s). The Commission will...

  10. 40 CFR 146.10 - Plugging and abandoning Class I, II, III, IV, and V wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM: CRITERIA AND STANDARDS General... of drinking water. The Director may allow Class III wells to use other plugging materials if the... sources of drinking water. (2) Placement of the cement plugs shall be accomplished by one of the following...

  11. 40 CFR 147.751 - EPA-administered program.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Indiana § 147.751 EPA-administered program. (a) Contents. The UIC program for all classes of wells on Indian lands, and for Class I, III, IV, and V wells on non-Indian lands in the State of Indiana is administered by the EPA. The...

  12. 40 CFR 147.751 - EPA-administered program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Indiana § 147.751 EPA-administered program. (a) Contents. The UIC program for all classes of wells on Indian lands, and for Class I, III, IV, and V wells on non-Indian lands in the State of Indiana is administered by the EPA. The...

  13. 40 CFR 147.101 - EPA-administered program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Alaska § 147.101 EPA-administered program. (a) Contents. The UIC program in the State of Alaska for Class I, III, IV, and V wells, and for all classes of wells on Indian lands, is administered by EPA. This program consists of the UIC...

  14. Working Smarter, Not Harder (Part IV).

    ERIC Educational Resources Information Center

    LaBelle, Sandy

    2003-01-01

    Discusses ways of improving student attitudes and motivation, such as changing the focus of tests, making students responsible for their work, using a grid to show test results, instituting in-class breaks, using a personal grade book, discussing with students the effects of sleep deprivation, and using separate folders for papers of each class.…

  15. The social class gradient in health in Spain and the health status of the Spanish Roma.

    PubMed

    La Parra Casado, Daniel; Gil González, Diana; de la Torre Esteve, María

    2016-10-01

    To determine the social class gradient in health in general Spain population and the health status of the Spanish Roma. The National Health Survey of Spanish Roma 2006 (sample size = 993 people; average age: 33.6 years; 53.1% women) and the National Health Surveys for Spain 2003 (sample size: 21,650 people; average age: 45.5 years; 51.2% women) and 2006 (sample size: 29,478 people; average age: 46 years; 50.7% women) are compared. Several indicators were chosen: self-perceived health, activity limitation, chronic diseases, hearing and sight problems, caries, and obesity. Analysis was based on age-standardised rates and logistic regression models. According to most indicators, Roma's health is worse than that of social class IV-V (manual workers). Some indicators show a remarkable difference between Roma and social class IV-V: experiencing three or more health problems, sight problems, and caries, in both sexes, and hearing problems and obesity, in women. Roma people are placed on an extreme position on the social gradient in health, a situation of extreme health inequality.

  16. Pea Chaperones under Centrifugation

    NASA Astrophysics Data System (ADS)

    Talalaiev, Oleksandr

    2008-06-01

    Etiolated Pisum sativum seedlings were subjected to altered g-forces by centrifugation (3-14g). By using semiquantitative RT-PCR, we studied transcripts of pea genes coding for chaperones that are representatives of small heat shock proteins (sHsps) family. Four members from the different classes of sHsps: cytosolic Hsp17.7 and Hsp18.1 (class I and class II accordingly), chloroplast Hsp21 (class III) and endoplasmic reticulum Hsp22.7 (class IV) were investigated. We conclude that exposure to 3, 7, 10 and 14g for 1h did not affect the level of sHsp transcripts.

  17. Effect of impurities and processing on silicon solar cells. Volume 1: Characterization methods for impurities in silicon and impurity effects data base

    NASA Technical Reports Server (NTRS)

    Hopkins, R. H.; Davis, J. R.; Rohatgi, A.; Campbell, R. B.; Blais, P. D.; Rai-Choudhury, P.; Stapleton, R. E.; Mollenkopf, H. C.; Mccormick, J. R.

    1980-01-01

    Two major topics are treated: methods to measure and evaluate impurity effects in silicon and comprehensive tabulations of data derived during the study. Discussions of deep level spectroscopy, detailed dark I-V measurements, recombination lifetime determination, scanned laser photo-response, conventional solar cell I-V techniques, and descriptions of silicon chemical analysis are presented and discussed. The tabulated data include lists of impurity segregation coefficients, ingot impurity analyses and estimated concentrations, typical deep level impurity spectra, photoconductive and open circuit decay lifetimes for individual metal-doped ingots, and a complete tabulation of the cell I-V characteristics of nearly 200 ingots.

  18. International Conference on Atomic Physics: Abstracts of Contributed Papers (12th) Held in Ann Arbor, Michigan on 29 July-3 August 1990

    DTIC Science & Technology

    1990-09-26

    A . Bloomfield IV-13 Obsenation of the 2SI12 - 2D51 2 transition in laser cooled trapped Y7) 4 A . S. Bell , H. A . Klein, G. P...discussed. I. H A Klein, A S Bell , G P Barwood and P Gill, Appl. Phys B 0, 13 (1990). 2. H A Klein, A S Bell , 0 P Barwood, P Gill and W R C Rowley...H.C.W. IV-6; X-1 Abu-Jafar, M. VII-41 Belkacem, A . VIII-23 Abutaleb, M. VIII-19 Bell , A.S. IV-13 Adachi, H. IX-1 Bengtsson, J. VIII-12 Aggarwal,

  19. IV INTERNATIONAL CONFERENCE ON ATOM AND MOLECULAR PULSED LASERS (AMPL'99): Surface oxide removal by a XeCl laser for decontamination

    NASA Astrophysics Data System (ADS)

    Sentis, M. L.; Delaporte, Ph; Marine, W.; Uteza, O.

    2000-06-01

    The laser ablation performed with an automated excimer XeCl laser unit is used for large surface cleaning. The study focuses on metal surfaces that are oxidised and are representative of contaminated surfaces with radionuclides in a context of nuclear power plant maintenance. The unit contains an XeCl laser, the beam delivery system, the particle collection cell, and the system for real-time control of cleaning processes. The interaction of laser radiation with a surface is considered, in particular, the surface damage caused by cleaning radiation. The beam delivery system consists of an optical fibre bundle of 5 m long and allows delivering 150 W at 308 nm for laser surface cleaning. The cleaning process is controlled by analysing in real time the plasma electric field evolution. The system permits the cleaning of 2 to 6 m2 h-1 of oxides with only slight substrate modifications.

  20. In vitro analysis of low-level laser irradiation on human osteoblast-like cells proliferation

    NASA Astrophysics Data System (ADS)

    Bloise, Nora; Saino, Enrica; Bragheri, Francesca; Minzioni, Paolo; Cristiani, Ilaria; Imbriani, Marcello; Visai, Livia

    2011-07-01

    The objective of this study was to examine the in vitro effect of a single or a multiple doses of low-level laser irradiation (LLLI) on proliferation of the human osteosarcoma cell line, SAOS-2. SAOS-2 cells were divided in five groups and exposed to LLLI (659 nm diode laser; 11 mW power output): group I as a control (dark), group II exposed to a single laser dose of 1 J/cm2, group III irradiated with a single dose of 3 J/cm2, and group IV and V exposed for three consecutive days to 1 or 3 J/cm², respectively. Cellular proliferation was assessed daily up to 7 days of culturing. The obtained results showed an increase in proliferative capacity of SAOS-2 cells during the first 96 h of culturing time in once-irradiated cells, as compared to control cells. Furthermore, a significantly higher proliferation in the group IV and V was detected if compared to a single dose or to control group after 96 h and 7 days. In conclusion, the effect of the single dose on cell proliferation was transitory and repeated irradiations were necessary to observe a strong enhancement of SAOS-2 growth. As a future perspective, we would like to determine the potential of LLLI as a new approach for promoting bone regeneration onto biomaterials.

  1. Inkjet Printing of Drug-Loaded Mesoporous Silica Nanoparticles-A Platform for Drug Development.

    PubMed

    Wickström, Henrika; Hilgert, Ellen; Nyman, Johan O; Desai, Diti; Şen Karaman, Didem; de Beer, Thomas; Sandler, Niklas; Rosenholm, Jessica M

    2017-11-21

    Mesoporous silica nanoparticles (MSNs) have shown great potential in improving drug delivery of poorly water soluble (BCS class II, IV) and poorly permeable (BCS class III, IV) drugs, as well as facilitating successful delivery of unstable compounds. The nanoparticle technology would allow improved treatment by reducing adverse reactions of currently approved drugs and possibly reintroducing previously discarded compounds from the drug development pipeline. This study aims to highlight important aspects in mesoporous silica nanoparticle (MSN) ink formulation development for digital inkjet printing technology and to advice on choosing a method (2D/3D) for nanoparticle print deposit characterization. The results show that both unfunctionalized and polyethyeleneimine (PEI) surface functionalized MSNs, as well as drug-free and drug-loaded MSN-PEI suspensions, can be successfully inkjet-printed. Furthermore, the model BCS class IV drug remained incorporated in the MSNs and the suspension remained physically stable during the processing time and steps. This proof-of-concept study suggests that inkjet printing technology would be a flexible deposition method of pharmaceutical MSN suspensions to generate patterns according to predefined designs. The concept could be utilized as a versatile drug screening platform in the future due to the possibility of accurately depositing controlled volumes of MSN suspensions on various materials.

  2. 2005 NDIA Combat Vehicles Conference. Volume 2- Thursday Presentations and Videos

    DTIC Science & Technology

    2005-09-22

    Mounted Combat System MULE: (Countermine) MULE: (Transport) Class II Class III Class IV Armed Robotic Vehicle ARV RSTA ARV Assault FCS Recovery and...Vehicles – Infantry Carrier Vehicle (ICV) – Armed Robotic Vehicle - Assault (ARV (A)) – Recon & Surveillance Vehicle (RSV)  Training Ammo for AP & AB...Holtz and Mr. Dick Williams, Boeing Mr. Dean Vanderstelt, General Dynamics Land Systems ( GDLS ) Mr. Mike Zoltoski, TARDEC Mr. Peter DeMasi, Program

  3. Four generations of sodium guide star lasers for adaptive optics in astronomy and space situational awareness

    NASA Astrophysics Data System (ADS)

    d'Orgeville, Céline; Fetzer, Gregory J.

    2016-07-01

    This paper recalls the history of sodium guide star laser systems used in astronomy and space situational awareness adaptive optics, analyzing the impact that sodium laser technology evolution has had on routine telescope operations. While it would not be practical to describe every single sodium guide star laser system developed to date, it is possible to characterize their evolution in broad technology terms. The first generation of sodium lasers used dye laser technology to create the first sodium laser guide stars in Hawaii, California, and Spain in the late 1980s and 1990s. These experimental systems were turned into the first laser guide star facilities to equip mediumto- large diameter adaptive optics telescopes, opening a new era of Laser Guide Star Adaptive Optics (LGS AO)-enabled diffraction-limited imaging from the ground. Although they produced exciting scientific results, these laser guide star facilities were large, power-hungry and messy. In the USA, a second-generation of sodium lasers was developed in the 2000s that used cleaner, yet still large and complex, solid-state laser technology. These are the systems in routine operation at the 8 to 10m-class astronomical telescopes and 4m-class satellite imaging facilities today. Meanwhile in Europe, a third generation of sodium lasers was being developed using inherently compact and efficient fiber laser technology, and resulting in the only commercially available sodium guide star laser system to date. Fiber-based sodium lasers are being or will soon be deployed at three astronomical telescopes and two space surveillance stations. These highly promising systems are still relatively large to install on telescopes and they remain significantly expensive to procure and maintain. We are thus proposing to develop a fourth generation of sodium lasers: based on semiconductor technology, these lasers could provide a definitive solution to the problem of sodium LGS AO laser sources for all astronomy and space situational awareness applications.

  4. Clinical features and histological patterns of lupus nephritis in a single center of South India.

    PubMed

    Devadass, Clement Wilfred; Mysorekar, Vijaya Viswanath; Eshwarappa, Mahesh; Mekala, Lakshminarayanan; Siddaiah, M Gireesh; Channabasappa, K Gurudev

    2016-01-01

    Renal involvement occurs in up to 60% of patients with systemic lupus erythematosus (SLE) and signifies a poor prognosis. The class of lupus nephritis (LN), determined on renal biopsy evaluation, guides the therapeutic management and has prognostic connotations. Our aim is to determine the clinicolaboratory features and histopathological patterns of LN at presentation in our local (South Indian) population. The study was conducted in a tertiary care hospital in South India between 2009 and 2014 on SLE patients with clinical evidence of LN. The renal biopsies were examined by light and immunofluorescence microscopy and were classified according to the International Society of Nephrology/Renal Pathology Society Classification of LN. A total of 46 patients were included, with age range of 12-60 years and a female to male ratio of 8.2:1. Arthritis, dermatological manifestations, and fever occurred, respectively, in 43.5%, 39.1%, and 30.4% of the cases. Class IV LN was present in 17 (37.1%), Class III LN in ten (21.7%), Class II LN in nine (19.5%), Class V LN in eight (17.4%), Class I LN in one (2.2%), and Class VI LN in one (2.2%) patients. Antinuclear antibody (ANA) and dsDNA positivity were present, respectively, in 82.6% and 65.2% of the patients. The most common pattern of LN was Class IV LN followed by Class III LN. Relatively higher proportions of ANA and anti-dsDNA positivity were present in proliferative LN, and there was a high frequency of arthritis at presentation in our LN patients.

  5. Latent classes of emotional and behavioural problems in epidemiological and referred samples and their relations to DSM-IV diagnoses.

    PubMed

    Bianchi, Valentina; Brambilla, Paolo; Garzitto, Marco; Colombo, Paola; Fornasari, Livia; Bellina, Monica; Bonivento, Carolina; Tesei, Alessandra; Piccin, Sara; Conte, Stefania; Perna, Giampaolo; Frigerio, Alessandra; Castiglioni, Isabella; Fabbro, Franco; Molteni, Massimo; Nobile, Maria

    2017-05-01

    Researchers' interest have recently moved toward the identification of recurrent psychopathological profiles characterized by concurrent elevations on different behavioural and emotional traits. This new strategy turned to be useful in terms of diagnosis and outcome prediction. We used a person-centred statistical approach to examine whether different groups could be identified in a referred sample and in a general-population sample of children and adolescents, and we investigated their relation to DSM-IV diagnoses. A latent class analysis (LCA) was performed on the Child Behaviour Checklist (CBCL) syndrome scales of the referred sample (N = 1225), of the general-population sample (N = 3418), and of the total sample. Models estimating 1-class through 5-class solutions were compared and agreement in the classification of subjects was evaluated. Chi square analyses, a logistic regression, and a multinomial logistic regression analysis were used to investigate the relations between classes and diagnoses. In the two samples and in the total sample, the best-fitting models were 4-class solutions. The identified classes were Internalizing Problems (15.68%), Severe Dysregulated (7.82%), Attention/Hyperactivity (10.19%), and Low Problems (66.32%). Subsequent analyses indicated a significant relationship between diagnoses and classes as well as a main association between the severe dysregulated class and comorbidity. Our data suggested the presence of four different psychopathological profiles related to different outcomes in terms of psychopathological diagnoses. In particular, our results underline the presence of a profile characterized by severe emotional and behavioural dysregulation that is mostly associated with the presence of multiple diagnosis.

  6. Microleakage in conservative cavities varying the preparation method and surface treatment

    PubMed Central

    ATOUI, Juliana Abdallah; CHINELATTI, Michelle Alexandra; PALMA-DIBB, Regina Guenka; CORONA, Silmara Aparecida Milori

    2010-01-01

    Objective To assess microleakage in conservative class V cavities prepared with aluminum-oxide air abrasion or turbine and restored with self-etching or etch-and-rinse adhesive systems. Material and Methods Forty premolars were randomly assigned to 4 groups (I and II: air abrasion; III and IV: turbine) and class V cavities were prepared on the buccal surfaces. Conditioning approaches were: groups I/III - 37% phosphoric acid; groups II/IV -self-priming etchant (Tyrian-SPe). Cavities were restored with One Step Plus/Filtek Z250. After finishing, specimens were thermocycled, immersed in 50% silver nitrate, and serially sectioned. Microleakage at the occlusal and cervical interfaces was measured in mm and calculated by a software. Data were subjected to ANOVA and Tukey’s test (α=0.05). Results Forty premolars were randomly assigned to 4 groups (I and II: air abrasion; III and IV: turbine) and class V cavities were prepared on the buccal surfaces. Conditioning approaches were: groups I/III - 37% phosphoric acid; groups II/IV -self-priming etchant (Tyrian-SPe). Cavities were restored with One Step Plus/Filtek Z250. After finishing, specimens were thermocycled, immersed in 50% silver nitrate, and serially sectioned. Microleakage at the occlusal and cervical interfaces was measured in mm and calculated by a software. Data were subjected to ANOVA and Tukey’s test (α=0.05). Conclusion Marginal seal of cavities prepared with aluminum-oxide air abrasion was different from that of conventionally prepared cavities, and the etch-and-rinse system promoted higher marginal seal at both enamel and dentin margins. PMID:20835580

  7. A new, empirically established hypochondriasis diagnosis.

    PubMed

    Fink, Per; Ørnbøl, Eva; Toft, Tomas; Sparle, Kaj Christensen; Frostholm, Lisbeth; Olesen, Frede

    2004-09-01

    The narrow ICD-10 and DSM-IV definition of hypochondriasis makes it rarely used yet does not prevent extensive diagnosis overlap. This study identified a distinct hypochondriasis symptom cluster and defined diagnostic criteria. Consecutive patients (N=1,785) consulting primary care physicians for new illness were screened for somatization, anxiety, depression, and alcohol abuse. A stratified subgroup of 701 patients were interviewed with the Schedules for Clinical Assessment in Neuropsychiatry and questions addressing common hypochondriasis symptoms. Symptom patterns were analyzed by latent class analysis. Patients fell into three classes based on six symptoms: preoccupation with the idea of harboring an illness or with bodily function, rumination about illness, suggestibility, unrealistic fear of infection, fascination with medical information, and fear of prescribed medication. All symptoms, particularly rumination, were frequent in one of the classes. Classification allowed definition of new diagnostic criteria for hypochondriasis and division of the cases into "mild" and "severe." The weighted prevalence of severe cases was 9.5% versus 5.8% for DSM-IV hypochondriasis. Compared with DSM-IV hypochondriasis, this approach produced less overlap with other somatoform disorders, similar overlap with nonsomatoform psychiatric disorders, and similar assessments by primary care physicians. Severe cases of the new hypochondriasis lasted 2 or more years in 54.3% of the subjects and 1 month or less in 27.2%. These results suggest that rumination about illness plus at least one of five other symptoms form a distinct diagnostic entity performing better than the current DSM-IV hypochondriasis diagnosis. However, these criteria are preliminary, awaiting cross-validation in other subject groups.

  8. Levofloxacin 750-mg for 5 days for the treatment of hospitalized Fine Risk Class III/IV community-acquired pneumonia patients.

    PubMed

    Shorr, Andrew F; Khashab, Mohammed M; Xiang, Jim X; Tennenberg, Alan M; Kahn, James B

    2006-12-01

    The efficacy and safety of 750-mg, 5-day levofloxacin was recently shown to be comparable to 500-mg, 10-day levofloxacin in a randomized, double-blind, multicentre clinical trial for mild-to-severe community-acquired pneumonia (CAP). This subgroup analysis attempted to compare the safety and efficacy of a short-course levofloxacin regimen with traditional levofloxacin dosing for PSI Class III/IV patients. This retrospective, subgroup analysis focused on Pneumonia Severity Index Class III and IV patients enrolled in the study. Measurements included clinical and microbiological success rates, adverse events, and symptom resolution by day 3 of therapy. Of the 528 patients in the ITT population, 219 (41.5%) were categorized as PSI Class III/IV and included in this analysis. Among the clinically evaluable patients, 90.8% (69/76) of patients treated with the 750-mg regimen achieved clinical success, compared with 85.5% (71/83) treated with 500-mg levofloxacin (95% CI,-15.9 to 5.4). Eradication rates in the microbiologically evaluable population were comparable for the 750- and 500-mg regimens (88.9% vs 87.5%, respectively; 95% CI,-18.3 to 15.6). Both regimens were well tolerated and had comparable safety profiles. A greater proportion of patients in the 750-mg treatment group experienced resolution of fever (48.4% vs 34.0%; P=.046) and purulent sputum (48.4% vs 27.5%; P=.007) by day 3 of therapy. The 750-mg, 5-day levofloxacin course achieved comparable clinical and microbiologic efficacy to the 500-mg, 10-day regimen. By day 3 of therapy, a greater proportion of patients in the 750-mg group had objective and subjective resolution of fever. Further research is needed to determine the economic significance of short-course levofloxacin therapy.

  9. Evaluation of a technique for color correction in restoring anterior teeth.

    PubMed

    Rauber, Gabrielle Branco; Bernardon, Jussara Karina; Vieira, Luiz Clovis Cardoso; Baratieri, Luiz Narciso

    2017-09-01

    This study aimed to evaluate the ability of the proposed technique in producing restorations that exhibit mimesis with tooth structure and to define a restorative clinical protocol. For this study a typodont was used. The right upper central incisor with Class IV lesion was restored with the layering technique (reference tooth, RT). For the left upper central incisor with Class IV lesion, six teeth were restored monochromatically (test teeth, TT), using DA3.5 (n = 3) and DA4 (n = 3) composite resins-resulting in six unsatisfactory color restorations. TT were divided into six groups depending on the color of unsatisfactory restoration and preparation depth. First, a preparation was realized on the labial surface with 0.5 mm, 0.7 mm or 1.0 mm of depth. A second preparation was then performed to reproduce the dentinal mamelons. Next, adhesive procedures were performed and the teeth restored. Opaque halo, opalescent halo and vestibular enamel were then reproduced by the addition of different composite resins. The RT and TT were photographed side by side in typodont to obtain six photographic prints. The photographs of the groups were subjected to visual evaluation by 120 volunteers via a questionnaire. Data were analyzed by the prevalence of answers, and Chi-square test was used to investigate the association between variables at .05 significance. Furthermore, ΔE of groups was evaluated in comparison RT. The results demonstrated that the moderate intensity restorations (DA3.5) with depths of 0.5 mm and 0.7 mm had the highest prevalence of acceptance. For severe intensity restorations (DA4), the preparation depth of 1.0 mm obtained better acceptance. The technique was able to modify the final color of Class IV restorations, producing satisfactory color restorations. This technique can be used for color correction in cases of Class IV restorations, in situations where there is no time for immediate layered restoration, and as a restorative technique. © 2017 Wiley Periodicals, Inc.

  10. Spinal cord stimulation for patients with refractory angina and previous coronary surgery.

    PubMed

    Lapenna, Elisabetta; Rapati, Dino; Cardano, Paola; De Bonis, Michele; Lullo, Francesca; Zangrillo, Alberto; Alfieri, Ottavio

    2006-11-01

    Refractory angina pectoris is an exceptionally debilitating condition affecting patients who have typically failed multiple percutaneous and surgical revascularizations and optimal medical therapy and who are not amenable for further revascularization procedures. Spinal cord stimulation (SCS) has been adopted in this context at our institution and midterm mortality, anginal status, and quality of life have been evaluated. From 1998 to 2004, 51 patients with refractory class III-IV angina, who were not considered candidates for revascularization procedures, underwent SCS. All patients had already undergone previous surgical revascularization and a median of two percutaneous procedures. Transmyocardial laser revascularization had been previously performed in 8 cases (15.6%). Most of the patients (70.5%) had experienced a myocardial infarction. Mean ejection fraction was 0.42 +/- 0.121, Canadian Cardiovascular Society class 3.5 +/- 0.5, quality of life (Spitzer index) 4.5 +/- 1.2, and the median frequency of weekly angina episodes was 10. There were no SCS implantation-related complications. At follow-up (100% complete, mean 24 +/- 18 months), a significant improvement of anginal symptoms (>50% reduction of weekly anginal episodes) occurred in 45 patients (88.2%). In those patients (Responders), the quality of life improved significantly (6.8 +/- 1.5; p < 0.0001), CCS class decreased to 2 +/- 0.7 (p < 0.0001), and the median frequency of weekly angina episodes to 3 (p < 0.0001). At 3 years, Responders' survival was 91.8 +/- 4.6% and the freedom from cardiac events 72.6 +/- 8.42%. Spinal cord stimulation is a safe and effective procedure in truly no-option patients affected by refractory angina. A midterm sustained improvement of symptoms and quality of life have been documented with a satisfactory 3-year survival rate.

  11. Optimised design for a 1 kJ diode-pumped solid-state laser system

    NASA Astrophysics Data System (ADS)

    Mason, Paul D.; Ertel, Klaus; Banerjee, Saumyabrata; Phillips, P. Jonathan; Hernandez-Gomez, Cristina; Collier, John L.

    2011-06-01

    A conceptual design for a kJ-class diode-pumped solid-state laser (DPSSL) system based on cryogenic gas-cooled multislab ceramic Yb:YAG amplifier technology has been developed at the STFC as a building block towards a MJ-class source for inertial fusion energy (IFE) projects such as HiPER. In this paper, we present an overview of an amplifier design optimised for efficient generation of 1 kJ nanosecond pulses at 10 Hz repetition rate. In order to confirm the viability of this technology, a prototype version of this amplifier scaled to deliver 10 J at 10 Hz, DiPOLE, is under development at the Central Laser Facility. A progress update on the status of this system is also presented.

  12. Antihyperglycaemic effect of laser acupuncture treatment at BL20 in diabetic rats.

    PubMed

    Cornejo-Garrido, Jorge; Becerril-Chávez, Flavia; Carlín-Vargas, Gabriel; Ordoñez-Rodríguez, Juan Manuel; Abrajan-González, María Del Carmen; de la Cruz-Ramírez, Rosario; Ordaz-Pichardo, Cynthia

    2014-12-01

    To investigate the antihyperglycaemic activity of laser acupuncture stimulation at 650 and 980 nm at BL20 in streptozotocin (STZ)-induced diabetic rats. Seventy healthy adult male albino Wistar rats weighing 250±50 g were divided into seven groups of 10 animals each. Groups I-III comprised healthy control rats which were untreated (I) or stimulated with laser acupuncture at 650 nm (II) and 980 nm (III), respectively. Groups IV-VII underwent induction of diabetes with a single intraperitoneal administration of STZ at 50 mg/kg. Animals with blood glucose levels of ≥200 mg/dL on the fifth day were used for the experiments and were left untreated (group IV), treated with glibenclamide (group V) or stimulated with laser acupuncture at 650 nm (group VI) and 980 nm (group VII), respectively. Laser acupuncture was applied at BL20 on alternate days for a total of 12 sessions over a 28-day period. After 28 days of treatment, STZ-induced diabetic rats stimulated with laser acupuncture at 650 and 980 nm had significantly lower glucose levels compared with untreated diabetic rats (242.0±65.0 and 129.8±33.2 vs 376.5±10.0 mg/dL, both p≤0.05). Treatment at 980 nm also attenuated the increase in glucose between day 1 and day 28 compared with the glibenclamide-treated diabetic group (41.5±19.6 mg/dL vs 164.1±13.7 g/dL, p<0.05). Laser acupuncture treatment did not affect the blood count or biochemical profile and was not associated with any morphological changes in the pancreas, liver, kidney or spleen. Stimulation with laser acupuncture at 650 and 980 nm at BL20 in STZ-induced diabetic rats has antihyperglycaemic activity. The results support further evaluation of laser acupuncture as an alternative or complementary treatment for the control of hyperglycaemia. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. High power high repetition rate VCSEL array side-pumped pulsed blue laser

    NASA Astrophysics Data System (ADS)

    van Leeuwen, Robert; Zhao, Pu; Chen, Tong; Xu, Bing; Watkins, Laurence; Seurin, Jean-Francois; Xu, Guoyang; Miglo, Alexander; Wang, Qing; Ghosh, Chuni

    2013-03-01

    High power, kW-class, 808 nm pump modules based on the vertical-cavity surface-emitting laser (VCSEL) technology were developed for side-pumping of solid-state lasers. Two 1.2 kW VCSEL pump modules were implemented in a dual side-pumped Q-switched Nd:YAG laser operating at 946 nm. The laser output was frequency doubled in a BBO crystal to produce pulsed blue light. With 125 μs pump pulses at a 300 Hz repetition rate 6.1 W QCW 946 nm laser power was produced. The laser power was limited by thermal lensing in the Nd:YAG rod.

  14. Ytterbium-doped borate fluoride laser crystals and lasers

    DOEpatents

    Schaffers, Kathleen I.; DeLoach, Laura D.; Payne, Stephen A.; Keszler, Douglas A.

    1997-01-01

    A new class of solid state laser crystals and lasers are formed from Yb-doped borate fluoride host crystals. The general formula for the host crystals is MM'(BO.sub.3)F, where M, M' are monovalent, divalent aria trivalent metal cations. A particular embodiment of the invention is Yb-doped BaCaBO.sub.3 F (Yb:BCBF). BCBF and some of the related derivative crystals are capable of nonlinear frequency conversion, whereby the fundamental of the laser is converted to a longer or shorter wavelength. In this way, these new crystals can simultaneously serve as self-frequency doubling crystals and laser materials within the laser resonator.

  15. Equatorial Ligand Perturbations Influence the Reactivity of Manganese(IV)-Oxo Complexes.

    PubMed

    Massie, Allyssa A; Denler, Melissa C; Cardoso, Luísa Thiara; Walker, Ashlie N; Hossain, M Kamal; Day, Victor W; Nordlander, Ebbe; Jackson, Timothy A

    2017-04-03

    Manganese(IV)-oxo complexes are often invoked as intermediates in Mn-catalyzed C-H bond activation reactions. While many synthetic Mn IV -oxo species are mild oxidants, other members of this class can attack strong C-H bonds. The basis for these reactivity differences is not well understood. Here we describe a series of Mn IV -oxo complexes with N5 pentadentate ligands that modulate the equatorial ligand field of the Mn IV center, as assessed by electronic absorption, electron paramagnetic resonance, and Mn K-edge X-ray absorption methods. Kinetic experiments show dramatic rate variations in hydrogen-atom and oxygen-atom transfer reactions, with faster rates corresponding to weaker equatorial ligand fields. For these Mn IV -oxo complexes, the rate enhancements are correlated with both 1) the energy of a low-lying 4 E excited state, which has been postulated to be involved in a two-state reactivity model, and 2) the Mn III/IV reduction potentials. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Experimental AMO physics in undergraduate optics and lasers courses

    NASA Astrophysics Data System (ADS)

    Hoyt, Chad

    2017-04-01

    This talk will describe experimental AMO research projects in undergraduate Lasers and Optics courses at Bethel University. The courses, which include a comprehensive lecture portion, are built on open-ended projects that have a novel aspect. Classes begin with four weeks of small student groups rotating between several standard laser and optics laboratory exercises. These may include, for example, alignment and characterization of a helium neon laser and measurements with a Michelson interferometer or a scanning Fabry-Pérot optical cavity. During the following seven weeks of the course, student groups (2-4 people) choose and pursue research questions in the lab. Their work culminates in a group manuscript and a twenty-minute presentation to the class. Projects in the spring, 2016 Optics course included experiments with ultracold lithium atoms in a magneto-optical trap, a prototype, portable, mode-locked erbium fiber laser, a home-built fiber laser frequency comb, double-slit imaging with single photons, and digital holographic tweezers (led by Nathan Lindquist). Projects in the spring, 2015 Lasers course included ultrafast optics with a mode-locked erbium fiber laser, quantum optics, surface plasmon lasers (led by Nathan Lindquist) and a low-cost, near-infrared spectrometer. Several of these projects are related to larger scale, funded research in the physics department. The format and experience in Lasers and Optics is representative of other upper-level courses at Bethel, including Fluid Mechanics and Computer Methods. A physics education research group from the University of Colorado evaluated the spring, 2015 Lasers and 2016 Optics courses. They focused on student experimental attitudes and measurements of student project ownership.

  17. Relationship of serum uric acid and Killip class on mortality after acute ST-segment elevation myocardial infarction and primary percutaneous coronary intervention.

    PubMed

    Liu, Cheng-Wei; Liao, Pen-Chih; Chen, Kuo-Chin; Chiu, Yu-Wei; Liu, Yuan-Hung; Ke, Shin-Rong; Wu, Yen-Wen

    2017-01-01

    There is conflicting information regarding the association between hyperuricemia and survival in STEMI patients. Our study examined the interaction between hyperuricemia and Killip class on mortality of STEMI patients. We analyzed 951 consecutive STEMI patients between February 2006 and September 2012. Hyperuricemia was defined as SUA of at least 7mg/dL in males and 6mg/dL in females. Killip class I patients were divided into hyperuricemia and normouricemia groups. The Killip class I hyperuricemia and normouricemia groups had similar baseline and procedural characteristics, but the hyperuricemia group had significantly greater BMI, serum creatinine, and SUA, and a lower TIMI risk score (2, IQR: 1-4 vs. 3, IQR: 2-4, p=0.019). The hyperuricemia group also had greater 30-day and 1-year mortality rates (2.9% vs. 0.3%, p=0.022; 6.5% vs. 1.1%, p=0.002, respectively). However, hyperuricemia was not associated with mortality of patients in Killip classes II-IV or in the overall study population. Hyperuricemia was associated with increased mortality in subgroups of patients who were at least 65years-old, male, had BMI of 25kg/m 2 or less, were in Killip class I, without diabetes, and who did not receive intra-aortic balloon pump support. Hyperuricemia interacted with Killip class I in increasing the risk for 1-year mortality (p for interaction=0.038). Hyperuricemia increased the 1-year mortality of STEMI patients in Killip class I, but not of patients in Killip classes II-IV. An interaction of hyperuricemia and Killip class significantly affects the mortality of STEMI patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Fluorescence measurement of diode (805 nm) laser-induced release of 5,6-CF from DSPC liposomes for monitoring of temperature: an in vivo study in rat liver using indocyanine green potentiation

    NASA Astrophysics Data System (ADS)

    Mordon, Serge R.; Desmettre, Thomas; Devoisselle, Jean-Marie; Soulie-Begu, Sylvie

    1995-05-01

    This in-vivo study examines the validity of fluorescence measurement of laser-induced release of temperature sensitive liposome-encapsulated dye for monitoring of temperature and prediction of tissue thermal damage. It is performed in rat liver after i.v. injection of liposomes loaded with a fluorescent dye and i.v. injection of Indocyanine Green (ICG) for diode laser potentiation. Temperature sensitive liposomes (DSPC: Di- Stearoyl-Phosphatidyl-Choline) are loaded with 5,6-Carboxyfluorescein (5,6-CF). These liposomes (1.5 ml solution) and ICG (1.5 ml solution-5 mg/kg) are injected to adult male wistar rats. Two hours later, the liver is exposed and irradiated with a 0.8 W diode laser using pulses lasting from 1 s to 6 s (fluence ranging from 16 to 98 J/cm+2)). Simultaneously, the fluorescence emission is measured with a fluorescent imaging system. Results show that the fluorescence intensity increases linearly form 18 J/cm2 up to 75 J/cm2. These fluences correspond to surface temperatures between 42°C to 64°C. The measurements appear to be highly reproducible. In this temperature range, the accuracy is +/- 3°C. The maximum intensity is observed immediately after the laser is switched off and a decrease of the fluorescence intensity is observed (27% in 20 minutes) due to the 5.6-CF clearance. However, the ratio (IF/Ibck) remains almost stable over this period of time and the determination of the temperature is still possible with a good accuracy even 20 minutes after laser irradiation. In conclusion, temperature monitoring by using fluorescence measurement of laser-induced release of liposome-encapsulated dye is clearly demonstrated. This procedure could conceivably prove useful for controlling the thermal coagulation of biological tissues.

  19. Cylindrical laser resonator

    DOEpatents

    Casperson, Lee W.

    1976-02-24

    The properties of an improved class of lasers is presented. In one configuration of these lasers the radiation propagates radially within the amplifying medium, resulting in high fields and symmetric illumination at the resonator axis. Thus there is a strong focusing of energy at the axis of the resonator. In a second configuration the radiation propagates back and forth in a tubular region of space.

  20. A focal-spot diagnostic for on-shot characterization of high-energy petawatt lasers.

    PubMed

    Bromage, J; Bahk, S-W; Irwin, D; Kwiatkowski, J; Pruyne, A; Millecchia, M; Moore, M; Zuegel, J D

    2008-10-13

    An on-shot focal-spot diagnostic for characterizing high-energy, petawatt-class laser systems is presented. Accurate measurements at full energy are demonstrated using high-resolution wavefront sensing in combination with techniques to calibrate on-shot measurements with low-power sample beams. Results are shown for full-energy activation shots of the OMEGA EP Laser System.

  1. PW-class laser-driven super acceleration systems in underdense plasmas

    NASA Astrophysics Data System (ADS)

    Yano, Masahiro; Zhidkov, Alexei; Kodama, Ryosuke

    2017-10-01

    Probing laser driven super-acceleration systems can be important tool to understand physics related to vacuum, space time, and particle acceleration. We show two proposals to probe the systems through Hawking-like effect using PW class lasers and x-ray free electron lasers. For that we study the interaction of ultrahigh intense laser pulses with intensity 1022 -1024 W/cm2 and underdense plasmas including ion motion and plasma radiation for the first time. While the acceleration w a0ωp /ωL in a wake is not maximal, the pulse propagation is much stable. The effect is that a constantly accelerated detector with acceleration w sees a boson's thermal bath at temperature ℏw / 2 πkB c . We present two designs for x-ray scattering from highly accelerated electrons produced in the plasma irradiated by intense laser pulses for such detection. Properly chosen observation angles enable us to distinguish spectral broadening from Doppler shift with a reasonable photon number. Also, ion motion and radiation damping on the interaction are investigated via fully relativistic 3D particle-in-cell simulation. We observe high quality electron bunches under super-acceleration when transverse plasma waves are excited by ponderomotive force producing plasma channel.

  2. Diode Pumped Alkaline Laser System: A High Powered, Low SWaP Directed Energy Option for Ballistic Missile Defense High-Level Summary - April 2017

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wisoff, P. J.

    The Diode-Pumped Alkali Laser (DPAL) system is an R&D effort funded by the Missile Defense Agency (MDA) underway at Lawrence Livermore National Laboratory (LLNL). MDA has described the characteristics needed for a Boost Phase directed energy (DE) weapon to work against ICBM-class threat missiles. In terms of the platform, the mission will require a high altitude Unmanned Aerial Vehicle (UAV) that can fly in the “quiet” stratosphere and display long endurance – i.e., days on station. In terms of the laser, MDA needs a high power, low size and weight laser that could be carried by such a platform andmore » deliver lethal energy to an ICBM-class threat missile from hundreds of kilometers away. While both the military and industry are pursuing Directed Energy for tactical applications, MDA’s objectives pose a significantly greater challenge than other current efforts in terms of the power needed from the laser, the low size and weight required, and the range, speed, and size of the threat missiles. To that end, MDA is funding two R&D efforts to assess the feasibility of a high power (MWclass) and low SWaP (size, weight and power) laser: a fiber combining laser (FCL) project at MIT’s Lincoln Laboratory, and LLNL’s Diode-Pumped Alkali Laser (DPAL) system.« less

  3. Structural Basis for Assembly of the MnIV/FeIII Cofactor in the Class Ic Ribonucleotide Reductase from Chlamydia trachomatis‡

    PubMed Central

    Dassama, Laura M.K.; Krebs, Carsten; Bollinger, J. Martin; Rosenzweig, Amy C.; Boal, Amie K.

    2013-01-01

    The class Ic ribonucleotide reductase (RNR) from Chlamydia trachomatis (Ct) employs a MnIV/FeIII cofactor in each monomer of its β2 subunit to initiate nucleotide reduction. The cofactor forms by reaction of MnII/FeII-β2 with O2. Previously, in vitro cofactor assembly from apo β2 and divalent metal ions produced a mixture of two forms, with Mn in site 1 (MnIV/FeIII) or site 2 (FeIII/MnIV), of which the more active MnIV/FeIII product predominates. Here we have addressed the basis for metal site-selectivity by solving X-ray crystal structures of apo, MnII, and MnII/FeII complexes of Ct β2. A structure obtained anaerobically with equimolar MnII, FeII, and apo protein reveals exclusive incorporation of MnII in site 1 and FeII in site 2, in contrast to the more modest site-selectivity achieved previously. Site-specificity is controlled thermodynamically by the apo protein structure, as only minor adjustments of ligands occur upon metal binding. Additional structures imply that, by itself, MnII binds in either site. Together the structures are consistent with a model for in vitro cofactor assembly in which FeII specificity for site 2 drives assembly of the appropriately configured heterobimetallic center, provided that FeII is substoichiometric. This model suggests that use of an MnIV/FeIII cofactor in vivo could be an adaptation to FeII limitation. A 1.8 Å resolution model of the MnII/FeII-β2 complex reveals additional structural determinants for activation of the cofactor, including a proposed site for side-on (η2) addition of O2 to FeII and a short (3.2 Å) MnII-FeII interionic distance, promoting formation of the MnIV/FeIV activation intermediate. PMID:23924396

  4. Guiding of laser pulses in plasma waveguides created by linearly-polarized femtosecond laser pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lemos, N.; Cardoso, L.; Geada, J.

    We experimentally demonstrate that plasma waveguides produced with ultra-short laser pulses (sub-picosecond) in gas jets are capable of guiding high intensity laser pulses. This scheme has the unique ability of guiding a high-intensity laser pulse in a plasma waveguide created by the same laser system in the very simple and stable experimental setup. A hot plasma column was created by a femtosecond class laser that expands into an on-axis parabolic low density profile suitable to act as a waveguide for high intensity laser beams. We have successfully guided ~10 15 W cm -2 laser pulses in a 8 mm longmore » hydrogen plasma waveguide with a 35% guiding efficiency.« less

  5. Guiding of laser pulses in plasma waveguides created by linearly-polarized femtosecond laser pulses

    DOE PAGES

    Lemos, N.; Cardoso, L.; Geada, J.; ...

    2018-02-16

    We experimentally demonstrate that plasma waveguides produced with ultra-short laser pulses (sub-picosecond) in gas jets are capable of guiding high intensity laser pulses. This scheme has the unique ability of guiding a high-intensity laser pulse in a plasma waveguide created by the same laser system in the very simple and stable experimental setup. A hot plasma column was created by a femtosecond class laser that expands into an on-axis parabolic low density profile suitable to act as a waveguide for high intensity laser beams. We have successfully guided ~10 15 W cm -2 laser pulses in a 8 mm longmore » hydrogen plasma waveguide with a 35% guiding efficiency.« less

  6. 25 CFR 547.12 - What are the minimum technical standards for downloading on a Class II gaming system?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... limited to software, files, data, and prize schedules. (2) Downloads must use secure methodologies that... date of the completion of the download; (iii) The Class II gaming system components to which software was downloaded; (iv) The version(s) of download package and any software downloaded. Logging of the...

  7. 25 CFR 547.12 - What are the minimum technical standards for downloading on a Class II gaming system?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... limited to software, files, data, and prize schedules. (2) Downloads must use secure methodologies that... date of the completion of the download; (iii) The Class II gaming system components to which software was downloaded; (iv) The version(s) of download package and any software downloaded. Logging of the...

  8. Wisconsin Technical College System Board Equity Staff Development Workshops and Services--Phase IV. Final Report.

    ERIC Educational Resources Information Center

    Baldus, Lorayne

    A staff development program on gender equity was conducted for personnel in Wisconsin's technical colleges using the train-the-trainer method. The training took two approaches: a class for college personnel and career challenge training for project directors of single parent and displaced homemaker grants. The inservice class resulted in increased…

  9. 76 FR 46838 - Notice of Proposed Class II Reinstatement of Terminated Oil and Gas Leases, Utah

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-03

    ... Proposed Class II Reinstatement of Terminated Oil and Gas Leases, Utah AGENCY: Bureau of Land Management, Interior. ACTION: Notice. SUMMARY: In accordance with Title IV of the Federal Oil and Gas Royalty... petition for reinstatement of oil and gas leases UTU-85226 and UTU-85230 lands in Uintah County, Utah, and...

  10. 77 FR 76069 - Notice of Proposed Class II Reinstatement of Terminated Oil and Gas Lease, Utah

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-26

    ... Proposed Class II Reinstatement of Terminated Oil and Gas Lease, Utah AGENCY: Bureau of Land Management, Interior. ACTION: Notice. SUMMARY: In accordance with Title IV of the Federal Oil and Gas Royalty Management Act, Quinex Energy Corporation timely filed a petition for reinstatement of oil and gas lease...

  11. 76 FR 66080 - Notice of Proposed Class II Reinstatement of Terminated Oil and Gas Lease, Utah

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-25

    ... Proposed Class II Reinstatement of Terminated Oil and Gas Lease, Utah AGENCY: Bureau of Land Management, Interior. ACTION: Notice. SUMMARY: In accordance with Title IV of the Federal Oil and Gas Royalty Management Act, Bro Energy LLC timely filed a petition for reinstatement of oil and gas lease UTU85562 lands...

  12. Gradient Index (GRIN) Lens Multimode Fiber Probe for Laser Induced Breakdown in the Eye

    DTIC Science & Technology

    1994-01-23

    34 Applied Optics, VoL 22, No. 3, p. 383, 1983 SPIE Vol. 2126 Ophthalmic Technologies IV (1994) /303 3. M. M. Pankratov , 0. Pomerantzeff, K. P...R. D. Jones, ’Laser-Produced Plasmas in Medicine," IEEE Transactions on Plasma Science, Vol. 19, p. 1209, 1991 6. T. I. Margolis, D. A. Farnath, M...Ophthalmology, Vol. 109, p.1605, 1991 8. P. Rol, P. Niederer, F. Fankhauser, M. Arigoni, E. De HaIler, ’p-Switched pulses and optical breakdown

  13. Research in the Optical Sciences.

    DTIC Science & Technology

    1981-01-30

    technology, as mirrors for laser weapons, and as protec- tive coatings in laser warfare. Three phases of the study were considered: 91. Laboratory...performance of simple metal coatings used on concentrating and flat-plate mirrors subject to high solar flux and heat, and on military mirrors used for...atI i :-a;t ;oil Cutiponlit -1of th >na"Cl I I C ’k lig ht cani be indi(ependent iv measured. 12 The scattering levels of most of the studied mirrors

  14. Investigation of Highly Unsteady Aerodynamics of Flapping Wings With/Without a Flexible Training Edge Using High Resolution MTV Measurements

    DTIC Science & Technology

    2013-10-14

    Aerodynamics Laboratory (TMUAL) at MSU. This modification , which was completed successfully, included two parts: (I) the addition of two large...quartz inserts and the 3 DOF motion system. The sketch also depicts a typical UV laser beam path for Molecular Tagging Velocimetry measurements UV laser ... beam UV mirror 3 IV.2. Airfoil Fabrication Using 3D Printing Methods For the parts of the investigation focused on studying the effect of

  15. The nociception genes painless and Piezo are required for the cellular immune response of Drosophila larvae to wasp parasitization.

    PubMed

    Tokusumi, Yumiko; Tokusumi, Tsuyoshi; Schulz, Robert A

    2017-05-13

    In vertebrates, interaction between the nervous system and immune system is important to protect a challenged host from stress inputs from external sources. In this study, we demonstrate that sensory neurons are involved in the cellular immune response elicited by wasp infestation of Drosophila larvae. Multidendritic class IV neurons sense contacts from external stimuli and induce avoidance behaviors for host defense. Our findings show that inactivation of these sensory neurons impairs the cellular response against wasp parasitization. We also demonstrate that the nociception genes encoding the mechanosensory receptors Painless and Piezo, both expressed in class IV neurons, are essential for the normal cellular immune response to parasite challenge. Copyright © 2017. Published by Elsevier Inc.

  16. [Evaluation of view points in forest park based on landscape sensitivity].

    PubMed

    Zhou, Rui; Li, Yue-hui; Hu, Yuan-man; Liu, Miao

    2008-11-01

    Based on topographical characteristics, five factors including comparative slope, comparative distance, mutual visibility, vision probability, and striking degree were chosen to assess the landscape sensitivity of major view points in Houshi National Forest Park. Spatial analysis in GIS was used for exploring the theory and method of landscape sensitivity of view points. The results showed that in the Park, there were totally 23 view points, but none of them reached up to class I. Among the 23 points, 10 were of class II , accounting for 43.5% of the total, 8 were of class III, accounting for 34.8%, and 5 were of classes IV and V, accounting for 21.7%. Around the view points of class II, the landscape should be strictly protected to maintain their natural feature; around the view points of class III, human-made landscape points should be developed according to the natural landscape feature, and wide tourism roads and small-size buildings could be constructed but the style of the buildings should be harmonious with surrounding nature landscape; while around the view points of classes IV and V, large-size multifunctional items and roads could be built to perfect the natural landscape. Through the multi-perspective and quantitative evaluation of landscape sensitivity, this study enriched the theory of landscape visual assessment and landscape apperception, and provided scientific base and direction for the planning and management of forest parks and other tourism areas.

  17. Megawatt-class free-electron laser concept for shipboard self-defense

    NASA Astrophysics Data System (ADS)

    Todd, Alan M. M.; Colson, William B.; Neil, George R.

    1997-05-01

    An efficient MW-class free electron laser (FEL) directed energy weapon (DEW) system holds promise for satisfying shipboard self-defense (SSD) requirements on future generations of Navy vessels because of the potential for high- power operation and the accessibility to all IR wavelengths. In order to meet shipboard packaging and prime power constraints, the power efficiency and high real-estate gradient achievable in a FEL driven by a superconducting rf accelerator is attractive. Configuration options and the key development issues for such a system are described.

  18. Atom Interferometry in a Warm Vapor

    DOE PAGES

    Biedermann, G. W.; McGuinness, H. J.; Rakholia, A. V.; ...

    2017-04-17

    Here, we demonstrate matter-wave interference in a warm vapor of rubidium atoms. Established approaches to light-pulse atom interferometry rely on laser cooling to concentrate a large ensemble of atoms into a velocity class resonant with the atom optical light pulse. In our experiment, we show that clear interference signals may be obtained without laser cooling. This effect relies on the Doppler selectivity of the atom interferometer resonance. Lastly, this interferometer may be configured to measure accelerations, and we demonstrate that multiple interferometers may be operated simultaneously by addressing multiple velocity classes.

  19. Simulations of High-Gain Shock-Ignited Inertial-Confinement-Fusion Implosions Using Less Than 1 MJ of Direct KrF Laser Energy

    DTIC Science & Technology

    2009-05-01

    transport, and thermonuclear burn. Using FAST, three classes of shock-ignited targets were designed that achieve one-dimensional fusion - energy gains in the...MJ) G a in Figure 1: Results of one-dimensional simulations showing the fusion energy gain as a function of KrF laser energy for three classes of...rises smoothly (according to a double power (a) Spike width: 160 ps (b) Spike power: 1530 TW Figure 4: Examples of fusion - energy gain contours for a shock

  20. Histological and ultrastructural effect of an Nd:YAG pulsed laser beam on dental hard tissue and pulp

    NASA Astrophysics Data System (ADS)

    Vignato, Costantino; Vignato, Giuseppe; Nardelli, Antonella; Baldan, Arianna; Mason, Pier N.

    1994-09-01

    The purpose of this study was to determine histological and ultrastructural modifications produced by an Nd:YAG pulsed laser beam after an in vivo exposure of human molars. Using a Nd:YAG pulsed laser beam delivered by a 600 micrometers optical fiber and concurrent air and water cooling spray, 14 human third molars with artificial first class cavities were exposed at different power levels (6, 7, and 8 W). All the teeth were extracted at different time periods between 10 and 25 days and prepared for histological examination. The results of the histological examination showed no evidence of degeneration or necrosis of the pulpar tissue. Analysis of the dentinal surfaces after exposure demonstrated that the dentinal tubules are completely closed due to the melted dentin. In conclusion a Nd:YAG pulsed laser beam with an air and water cooling spray is safe for treatments of class I decay and no necrosis or degeneration of the pulp was found for laser powers of 6, 7, and 8 W.

  1. Stable generation of GeV-class electron beams from self-guided laser-plasma channels

    NASA Astrophysics Data System (ADS)

    Hafz, Nasr A. M.; Jeong, Tae Moon; Choi, Il Woo; Lee, Seong Ku; Pae, Ki Hong; Kulagin, Victor V.; Sung, Jae Hee; Yu, Tae Jun; Hong, Kyung-Han; Hosokai, Tomonao; Cary, John R.; Ko, Do-Kyeong; Lee, Jongmin

    2008-09-01

    Table-top laser-driven plasma accelerators are gaining attention for their potential use in miniaturizing future high-energy accelerators. By irradiating gas jet targets with ultrashort intense laser pulses, the generation of quasimonoenergetic electron beams was recently observed. Currently, the stability of beam generation and the ability to scale to higher electron beam energies are critical issues for practical laser acceleration. Here, we demonstrate the first generation of stable GeV-class electron beams from stable few-millimetre-long plasma channels in a self-guided wakefield acceleration process. As primary evidence of the laser wakefield acceleration in a bubble regime, we observed a boost of both the electron beam energy and quality by reducing the plasma density and increasing the plasma length in a 1-cm-long gas jet. Subsequent three-dimensional simulations show the possibility of achieving even higher electron beam energies by minimizing plasma bubble elongation, and we anticipate dramatic increases in beam energy and quality in the near future. This will pave the way towards ultracompact, all-optical electron beam accelerators and their applications in science, technology and medicine.

  2. IV INTERNATIONAL CONFERENCE ON ATOM AND MOLECULAR PULSED LASERS (AMPL'99): Efficiency of an H2—SF6 laser with electron-beam initiation of chemical reactions

    NASA Astrophysics Data System (ADS)

    Erofeev, M. V.; Orlovskii, Viktor M.; Skakun, V. S.; Sosnin, E. A.; Tarasenko, Viktor F.

    2000-06-01

    The spectral and amplitude—time characteristics of HF lasers pumped by a nonchain chemical reaction and initiated by radially convergent and planar electron beams were investigated. The principal channels leading to the formation of vibrationally excited HF molecules were analysed. It was confirmed that high efficiencies (~10%) of a nonchain HF laser may be attained only as a result of the simultaneous formation of atomic and molecular fluorine when the active mixture is acted upon by an electron beam and of the participation of molecular fluorine in population inversion. It was shown that a laser pulse has a complex spectral—temporal profile caused by the successive generation of P-lines and the overlap during the radiation pulse of both the rotational lines of the same vibrational band and of individual vibrational bands.

  3. Advanced Accelerators for Medical Applications

    NASA Astrophysics Data System (ADS)

    Uesaka, Mitsuru; Koyama, Kazuyoshi

    We review advanced accelerators for medical applications with respect to the following key technologies: (i) higher RF electron linear accelerator (hereafter “linac”); (ii) optimization of alignment for the proton linac, cyclotron and synchrotron; (iii) superconducting magnet; (iv) laser technology. Advanced accelerators for medical applications are categorized into two groups. The first group consists of compact medical linacs with high RF, cyclotrons and synchrotrons downsized by optimization of alignment and superconducting magnets. The second group comprises laser-based acceleration systems aimed of medical applications in the future. Laser plasma electron/ion accelerating systems for cancer therapy and laser dielectric accelerating systems for radiation biology are mentioned. Since the second group has important potential for a compact system, the current status of the established energy and intensity and of the required stability are given.

  4. Discovery of 2-[4-{{2-(2S,5R)-2-cyano-5-ethynyl-1-pyrrolidinyl]-2-oxoethyl]amino]- 4-methyl-1-piperidinyl]-4-pyridinecarboxylic acid (ABT-279): a very potent, selective, effective, and well-tolerated inhibitor of dipeptidyl peptidase-IV, useful for the treatment of diabetes.

    PubMed

    Madar, David J; Kopecka, Hana; Pireh, Daisy; Yong, Hong; Pei, Zhonghua; Li, Xiaofeng; Wiedeman, Paul E; Djuric, Stevan W; Von Geldern, Thomas W; Fickes, Michael G; Bhagavatula, Lakshmi; McDermott, Todd; Wittenberger, Steven; Richards, Steven J; Longenecker, Kenton L; Stewart, Kent D; Lubben, Thomas H; Ballaron, Stephen J; Stashko, Michael A; Long, Michelle A; Wells, Heidi; Zinker, Bradley A; Mika, Amanda K; Beno, David W A; Kempf-Grote, Anita J; Polakowski, James; Segreti, Jason; Reinhart, Glenn A; Fryer, Ryan M; Sham, Hing L; Trevillyan, James M

    2006-10-19

    Dipeptidyl peptidase-IV (DPP-IV) inhibitors are poised to be the next major drug class for the treatment of type 2 diabetes. Structure-activity studies of substitutions at the C5 position of the 2-cyanopyrrolidide warhead led to the discovery of potent inhibitors of DPP-IV that lack activity against DPP8 and DPP9. Further modification led to an extremely potent (Ki(DPP)(-)(IV) = 1.0 nM) and selective (Ki(DPP8) > 30 microM; Ki(DPP9) > 30 microM) clinical candidate, ABT-279, that is orally available, efficacious, and remarkably safe in preclinical safety studies.

  5. Prediction of future uniform milk prices in Florida federal milk marketing order 6 from milk futures markets.

    PubMed

    De Vries, A; Feleke, S

    2008-12-01

    This study assessed the accuracy of 3 methods that predict the uniform milk price in Federal Milk Marketing Order 6 (Florida). Predictions were made for 1 to 12 mo into the future. Data were from January 2003 to May 2007. The CURRENT method assumed that future uniform milk prices were equal to the last announced uniform milk price. The F+BASIS and F+UTIL methods were based on the milk futures markets because the futures prices reflect the market's expectation of the class III and class IV cash prices that are announced monthly by USDA. The F+BASIS method added an exponentially weighted moving average of the difference between the class III cash price and the historical uniform milk price (also known as basis) to the class III futures price. The F+UTIL method used the class III and class IV futures prices, the most recently announced butter price, and historical utilizations to predict the skim milk prices, butterfat prices, and utilizations in all 4 classes. Predictions of future utilizations were made with a Holt-Winters smoothing method. Federal Milk Marketing Order 6 had high class I utilization (85 +/- 4.8%). Mean and standard deviation of the class III and class IV cash prices were $13.39 +/- 2.40/cwt (1 cwt = 45.36 kg) and $12.06 +/- 1.80/cwt, respectively. The actual uniform price in Tampa, Florida, was $16.62 +/- 2.16/cwt. The basis was $3.23 +/- 1.23/cwt. The F+BASIS and F+UTIL predictions were generally too low during the period considered because the class III cash prices were greater than the corresponding class III futures prices. For the 1- to 6-mo-ahead predictions, the root of the mean squared prediction errors from the F+BASIS method were $1.12, $1.20, $1.55, $1.91, $2.16, and $2.34/cwt, respectively. The root of the mean squared prediction errors ranged from $2.50 to $2.73/cwt for predictions up to 12 mo ahead. Results from the F+UTIL method were similar. The accuracies of the F+BASIS and F+UTIL methods for all 12 fore-cast horizons were not significantly different. Application of the modified Mariano-Diebold tests showed that no method included all the information contained in the other methods. In conclusion, both F+BASIS and F+UTIL methods tended to more accurately predict the future uniform milk prices than the CURRENT method, but prediction errors could be substantial even a few months into the future. The majority of the prediction error was caused by the inefficiency of the futures markets to predict the class III cash prices.

  6. Permanent work incapacity, mortality and survival without work incapacity among occupations and social classes: a cohort study of ageing men in Geneva.

    PubMed

    Gubéran, E; Usel, M

    1998-12-01

    The objective of this retrospective cohort study was to investigate the burden of disability and death in men, from middle age to age of retirement, among occupational groups and classes in Geneva. Men were included if they resided in the Canton of Geneva, were 45 years of age in 1970-1972, and were not receiving a disability pension at the start of the follow-up. The cohort of 5137 men was followed up for 20 years and linked to national registers of disability pension allowance and of causes of death. There was a steep upward trend in incidence of permanent work incapacity with lower social class for all causes as well as for the seven causes of disability studied. Compared with professional occupations (social class I), the relative risk (RR) of permanent work incapacity was 11.4 for partly skilled and unskilled occupations (class IV+V) (95% confidence interval [CI]: 5.2-28.0). The social class gradient in mortality was in the same direction as that in work incapacity although much less steep (RR class IV+V to class I = 1.6, 95% CI : 1.1-2.2). Survival without work incapacity at the time of the 65th birthday ranged from only 57% in construction workers and labourers to 89% in science and related professionals. Unemployment in Geneva was below 1.5% during almost all the study period. Medically-ascertained permanent work incapacity and survival without work incapacity have shown considerably greater socioeconomic differentials than the mortality differentials.

  7. Optically Pumped Atomic Rubidium Lasers: Two-Photon and Exciplex Excitation Mechanisms

    DTIC Science & Technology

    2013-06-01

    gain is very high with photon build-up times of 1−3.7 ns. Laser induced heating and subsequent condensation of alkali vapor in the heat pipe...encouragement during our time in classes, and recommendations while in the lab were invaluable. Finally, I want to thank the High Energy Laser Joint...intensity. The more non-traditional method is to use a single laser pulse to sketch out all needed energies. A photon build-up time was determined from

  8. Social class inequalities in the use of and access to health services in Catalonia, Spain: what is the influence of supplemental private health insurance?

    PubMed

    Borrell, C; Fernandez, E; Schiaffino, A; Benach, J; Rajmil, L; Villalbi, J R; Segura, A

    2001-04-01

    To analyse social class inequalities in the access to and utilization of health services in Catalonia (Spain), and the influence of having private health insurance supplementing the National Health System (NHS) coverage. 1994 Catalan Health Interview Survey, a cross-sectional survey conducted in 1994. Catalonia (Spain). The participants were a representative sample of people aged over 14 years from the non-institutionalized population of Catalonia (n = 12,245). Health services utilization, perceived health, having only NHS or NHS plus a private health insurance, and social class. Although one-quarter of the population of Catalonia had a supplemental private health insurance, percentages were very different according to social class, ranging from almost 50% for classes I and II to 16% for classes IV and V in both sexes. No inequalities by social class were observed for the utilization of non-preventive health care services (consultation with a health professional in the last 2 weeks and hospitalization in the last year) among persons with poor self-perceived health status, i.e. those in most need. However, social inequalities still remain in the use of health services provided only partially by the NHS, and when characteristics of last consultation are taken into account. Subjects who paid for a private service waited an average of 18.8 minutes less than those attending the NHS. Within the NHS, social classes IV and V waited longer (35.5 minutes) than social classes I and II (28.4 minutes). The NHS in Catalonia, Spain, has reduced inequalities in the use of health services. Social inequalities remain in the use of those health services provided only partially by the NHS.

  9. Ytterbium-doped borate fluoride laser crystals and lasers

    DOEpatents

    Schaffers, K.I.; DeLoach, L.D.; Payne, S.A.; Keszler, D.A.

    1997-10-14

    A new class of solid state laser crystals and lasers are formed from Yb-doped borate fluoride host crystals. The general formula for the host crystals is MM{prime}(BO{sub 3})F, where M, M{prime} are monovalent, divalent aria trivalent metal cations. A particular embodiment of the invention is Yb-doped BaCaBO{sub 3}F (Yb:BCBF). BCBF and some of the related derivative crystals are capable of nonlinear frequency conversion, whereby the fundamental of the laser is converted to a longer or shorter wavelength. In this way, these new crystals can simultaneously serve as self-frequency doubling crystals and laser materials within the laser resonator. 6 figs.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walters, C.T.; Dulaney, J.L.; Campbell, B.E.

    Demonstrations of operation of a compact neodymium glass laser with average output powers greater than 1 kW for several seconds are reported. The laser is based on the thermal inertia laser (TIL) concept wherein a neodymium-doped glass rod is pumped uniformly without cooling during a burst mode of laser operation. Design principles for TIL devices and scaling to 100 kW class lasers are discussed. Experimental results for a low repetition-rate proof-of-concept pulsed device (30 J, 0.2 Hz) and a high repetition-rate pulsed prototype (40 J, 36 Hz) are presented and compared to numerical solutions for the laser rate equations withmore » temperature dependent cross-sections.« less

  11. An accurate laser radiometer for determining visible exposure times.

    PubMed

    Royston, D D

    1985-01-01

    A laser light radiometer has been developed for the Electro-Optics Branch of the Center for Devices and Radiological Health (CDRH). The radiometer measures direct laser radiation emitted in the visible spectrum. Based upon this measurement, the instrument's microprocessor automatically determines at what time duration the exposure to the measured laser radiation would exceed either the class I accessible emission limits of the Federal Performance Standard for laser products or the maximum permissible exposure limits of laser user safety standards. The instrument also features automatic background level compensation, pulse measurement capability, and self-diagnosis. Measurement of forward surface illumination levels preceding HpD photoradiation therapy is possible.

  12. Risk evaluation of possible human hazards by chemicals, particles, and infectious units

    NASA Astrophysics Data System (ADS)

    Weber, Lothar W.; Spleiss, Martin

    1996-12-01

    Formation of laser plume by laser-tissue interaction means an inhomogeneous, pluriphasic and dynamic multicomponent system of biological material and induced modifications. While IR_laser applications often simulate processes of thermal food preservation, UV-lasers favor formation of aromatic organic compounds as VOC. Along with traces of PAH, nitriles and O-/N-containing heterocyclic compounds two classes of dialkyldiketopyrroli(di)nes are special formed VOC as laser solvents. Inhalable particles or partially dried and modified biomass contain - along with infectious particles - a lot of temperature degradation products. Ames tests and Comet-assays gave hint to some mutagenic activities present in laser smoke.

  13. Overmanned and Undertrained: Preparing UAS Crewmembers for Unmanned Close Air Support

    DTIC Science & Technology

    2012-03-22

    collection and artillery observation platform to a much more sophisticated mission platform capable of unmanned cargo delivery, laser designation, electronic...VMU Mission Essential Task List ..............................................................................30 iv Table of Contents...Marine Corps ...........................................................................2 VMU Squadrons: Aircraft, Operations, and Missions

  14. Dynein-Dependent Transport of nanos RNA in Drosophila Sensory Neurons Requires Rumpelstiltskin and the Germ Plasm Organizer Oskar

    PubMed Central

    Xu, Xin; Brechbiel, Jillian L.

    2013-01-01

    Intracellular mRNA localization is a conserved mechanism for spatially regulating protein production in polarized cells, such as neurons. The mRNA encoding the translational repressor Nanos (Nos) forms ribonucleoprotein (RNP) particles that are dendritically localized in Drosophila larval class IV dendritic arborization (da) neurons. In nos mutants, class IV da neurons exhibit reduced dendritic branching complexity, which is rescued by transgenic expression of wild-type nos mRNA but not by a localization-compromised nos derivative. While localization is essential for nos function in dendrite morphogenesis, the mechanism underlying the transport of nos RNP particles was unknown. We investigated the mechanism of dendritic nos mRNA localization by analyzing requirements for nos RNP particle motility in class IV da neuron dendrites through live imaging of fluorescently labeled nos mRNA. We show that dynein motor machinery components mediate transport of nos mRNA in proximal dendrites. Two factors, the RNA-binding protein Rumpelstiltskin and the germ plasm protein Oskar, which are required for diffusion/entrapment-mediated localization of nos during oogenesis, also function in da neurons for formation and transport of nos RNP particles. Additionally, we show that nos regulates neuronal function, most likely independent of its dendritic localization and function in morphogenesis. Our results reveal adaptability of localization factors for regulation of a target transcript in different cellular contexts. PMID:24027279

  15. Dynein-dependent transport of nanos RNA in Drosophila sensory neurons requires Rumpelstiltskin and the germ plasm organizer Oskar.

    PubMed

    Xu, Xin; Brechbiel, Jillian L; Gavis, Elizabeth R

    2013-09-11

    Intracellular mRNA localization is a conserved mechanism for spatially regulating protein production in polarized cells, such as neurons. The mRNA encoding the translational repressor Nanos (Nos) forms ribonucleoprotein (RNP) particles that are dendritically localized in Drosophila larval class IV dendritic arborization (da) neurons. In nos mutants, class IV da neurons exhibit reduced dendritic branching complexity, which is rescued by transgenic expression of wild-type nos mRNA but not by a localization-compromised nos derivative. While localization is essential for nos function in dendrite morphogenesis, the mechanism underlying the transport of nos RNP particles was unknown. We investigated the mechanism of dendritic nos mRNA localization by analyzing requirements for nos RNP particle motility in class IV da neuron dendrites through live imaging of fluorescently labeled nos mRNA. We show that dynein motor machinery components mediate transport of nos mRNA in proximal dendrites. Two factors, the RNA-binding protein Rumpelstiltskin and the germ plasm protein Oskar, which are required for diffusion/entrapment-mediated localization of nos during oogenesis, also function in da neurons for formation and transport of nos RNP particles. Additionally, we show that nos regulates neuronal function, most likely independent of its dendritic localization and function in morphogenesis. Our results reveal adaptability of localization factors for regulation of a target transcript in different cellular contexts.

  16. Oxygen discharge and post-discharge kinetics experiments and modeling for the electric oxygen-iodine laser system.

    PubMed

    Palla, A D; Zimmerman, J W; Woodard, B S; Carroll, D L; Verdeyen, J T; Lim, T C; Solomon, W C

    2007-07-26

    Laser oscillation at 1315 nm on the I(2P1/2)-->I(2P3/2) transition of atomic iodine has been obtained by a near resonant energy transfer from O2(a1Delta) produced using a low-pressure oxygen/helium/nitric oxide discharge. In the electric discharge oxygen-iodine laser (ElectricOIL) the discharge production of atomic oxygen, ozone, and other excited species adds levels of complexity to the singlet oxygen generator (SOG) kinetics which are not encountered in a classic purely chemical O2(a1Delta) generation system. The advanced model BLAZE-IV has been introduced to study the energy-transfer laser system dynamics and kinetics. Levels of singlet oxygen, oxygen atoms, and ozone are measured experimentally and compared with calculations. The new BLAZE-IV model is in reasonable agreement with O3, O atom, and gas temperature measurements but is under-predicting the increase in O2(a1Delta) concentration resulting from the presence of NO in the discharge and under-predicting the O2(b1Sigma) concentrations. A key conclusion is that the removal of oxygen atoms by NOX species leads to a significant increase in O2(a1Delta) concentrations downstream of the discharge in part via a recycling process; however, there are still some important processes related to the NOX discharge kinetics that are missing from the present modeling. Further, the removal of oxygen atoms dramatically inhibits the production of ozone in the downstream kinetics.

  17. Bone Repair on Fractures Treated with Osteosynthesis, ir Laser, Bone Graft and Guided Bone Regeneration: Histomorfometric Study

    NASA Astrophysics Data System (ADS)

    dos Santos Aciole, Jouber Mateus; dos Santos Aciole, Gilberth Tadeu; Soares, Luiz Guilherme Pinheiro; Barbosa, Artur Felipe Santos; Santos, Jean Nunes; Pinheiro, Antonio Luiz Barbosa

    2011-08-01

    The aim of this study was to evaluate, through the analysis of histomorfometric, the repair of complete tibial fracture in rabbits fixed with osteosynthesis, treated or not with infrared laser light (λ780 nm, 50 mW, CW) associated or not to the use of hydroxyapatite and guided bone regeneration (GBR). Surgical fractures were created, under general anesthesia (Ketamina 0,4 ml/Kg IP and Xilazina 0,2 ml/Kg IP), on the dorsum of 15 Oryctolagus rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with wire osteosynthesis. Animals of groups III and V were grafted with hydroxyapatite and GBR technique used. Animals of groups IV and V were irradiated at every other day during two weeks (16 J/cm2, 4×4 J/cm2). Observation time was that of 30 days. After animal death (overdose of general anesthetics) the specimes were routinely processed to wax and underwent histological analysis by light microscopy. The histomorfometric analysis showed an increased bone neoformation, increased collagen deposition, less reabsorption and inflammation when laser was associated to the HATCP. It is concluded that IR laser light was able to accelerate fracture healing and the association with HATCP and GBR resulted on increased deposition of CHA.

  18. Laser mimicking mosquito bites for skin delivery of malaria sporozoite vaccines.

    PubMed

    Zhou, Chang; Chen, Xinyuan; Zhang, Qi; Wang, Ji; Wu, Mei X

    2015-04-28

    Immunization with radiation-attenuated sporozoites (RAS) via mosquito bites has been shown to induce sterile immunity against malaria in humans, but this route of vaccination is neither practical nor ethical. The importance of delivering RAS to the liver through circulation in eliciting immunity against this parasite has been recently verified by human studies showing that high-level protection was achieved only by intravenous (IV) administration of RAS, not by intradermal (ID) or subcutaneous (SC) vaccination. Here, we report in a murine model that ID inoculation of RAS into laser-illuminated skin confers immune protection against malarial infection almost as effectively as IV immunization. Brief illumination of the inoculation site with a low power 532 nm Nd:YAG laser enhanced the permeability of the capillary beneath the skin, owing to hemoglobin-specific absorbance of the light. The increased blood vessel permeability appeared to facilitate an association of RAS with blood vessel walls by an as-yet-unknown mechanism, ultimately promoting a 7-fold increase in RAS entering circulation and reaching the liver over ID administration. Accordingly, ID immunization of RAS at a laser-treated site stimulated much stronger sporozoite-specific antibody and CD8(+)IFN-γ(+) T cell responses than ID vaccination and provided nearly full protection against malarial infection, whereas ID immunization alone was ineffective. This novel, safe, and convenient strategy to augment efficacy of ID sporozoite-based vaccines warrants further investigation in large animals and in humans. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Laser mimicking mosquito bites for skin delivery of malaria sporozoite vaccines

    PubMed Central

    Zhou, Chang; Chen, Xinyuan; Zhang, Qi; Wang, Ji; Wu, Mei X.

    2015-01-01

    Immunization with radiation-attenuated sporozoites (RAS) via mosquito bites has been shown to induce sterile immunity against malaria in humans, but this route of vaccination is neither practical nor ethical. The importance of delivering RAS to the liver through circulation in eliciting immunity against this parasite has been recently verified by human studies showing that high-level protection was achieved only by intravenous (IV) administration of RAS, but not by intradermal (ID) or subcutaneous (SC) vaccination. Here, we report in a murine model that ID inoculation of RAS into laser-illuminated skin confers immune protection against malarial infection almost as effectively as IV immunization. Brief illumination of the inoculation site with a low power 532 nm Nd:YAG laser enhanced the permeability of the capillary beneath the skin, owing to hemoglobin-specific absorbance of the light. The increased blood vessel permeability appeared to facilitate an association of RAS with blood vessel walls by an as-yet-unknown mechanism, ultimately promoting a 7-fold increase in RAS entering circulation and reaching the liver over ID administration. Accordingly, ID immunization of RAS at a laser-treated site stimulated much stronger sporozoite-specific antibody and CD8+IFN-γ+ T cell responses than ID vaccination and provided nearly full protection against malarial infection, whereas ID immunization alone was ineffective. This novel, safe, and convenient strategy to augment efficacy of ID sporozoite-based vaccines warrants further investigation in big animals and in humans. PMID:25725360

  20. Primary biliary cirrhosis degree assessment by acoustic radiation force impulse imaging and hepatic fibrosis indicators

    PubMed Central

    Zhang, Hai-Chun; Hu, Rong-Fei; Zhu, Ting; Tong, Ling; Zhang, Qiu-Qin

    2016-01-01

    AIM: To evaluate the assessment of primary biliary cirrhosis degree by acoustic radiation force impulse imaging (ARFI) and hepatic fibrosis indicators. METHODS: One hundred and twenty patients who developed liver cirrhosis secondary to primary biliary cirrhosis were selected as the observation group, with the degree of patient liver cirrhosis graded by Child-Pugh (CP) score. Sixty healthy individuals were selected as the control group. The four indicators of hepatic fibrosis were detected in all research objects, including hyaluronic acid (HA), laminin (LN), type III collagen (PC III), and type IV collagen (IV-C). The liver parenchyma hardness value (LS) was then measured by ARFI technique. LS and the four indicators of liver fibrosis (HA, LN, PC III, and IV-C) were observed in different grade CP scores. The diagnostic value of LS and the four indicators of liver fibrosis in determining liver cirrhosis degree with PBC, whether used alone or in combination, were analyzed by receiver operating characteristic (ROC) curve. RESULTS: LS and the four indicators of liver fibrosis within the three classes (A, B, and C) of CP scores in the observation group were higher than in the control group, with C class > B class > A class; the differences were statistically significant (P < 0.01). Although AUC values of LS within the three classes of CP scores were higher than in the four indicators of liver fibrosis, sensitivity and specificity were unstable. The ROC curves of LS combined with the four indicators of liver fibrosis revealed that: AUC and sensitivity in all indicators combined in the A class of CP score were higher than in LS alone, albeit with slightly decreased specificity; AUC and specificity in all indicators combined in the B class of CP score were higher than in LS alone, with unchanged sensitivity; AUC values (0.967), sensitivity (97.4%), and specificity (90%) of all indicators combined in the C class of CP score were higher than in LS alone (0.936, 92.1%, 83.3%). CONCLUSION: The diagnostic value of PBC cirrhosis degree in liver cirrhosis degree assessment by ARFI combined with the four indicators of serum liver fibrosis is of satisfactory effectiveness and has important clinical application value. PMID:27298571

  1. 49 CFR 232.205 - Class I brake test-initial terminal inspection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... § 232.205 Class I brake test-initial terminal inspection. (a) Each train and each car in the train shall... tested solid block of cars to the train; (iii) Changing motive power; (iv) Removing or changing the... conduct a brake test pursuant to § 232.209 on those cars added to the train. (B) [Reserved] (b) Except as...

  2. Assessment of the Treatability of Toxic Organics by Overland Flow,

    DTIC Science & Technology

    1983-01-01

    Tab’ I . Occunrence of organic chemsicals in household products . (After Hathaway 1980.1 Product Classter of organ iCs Product Classe of organirs...volatilization. the various classes of organics and their presence in Another important property of organic chemicals household products are given in Table 1...23 iv TABLES Table Page I. Occurrence of organic chemicals in household

  3. 78 FR 24334 - Milk in the Northeast and Other Marketing Areas; Order Amending the Orders

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-25

    ...) allowances for cheese, butter, nonfat dry milk (NFDM) and dry whey contained in the Class III and Class IV....1715 per pound); NFDM ($0.1678 per pound); and dry whey ($0.1991 per pound). In addition, the butterfat... dry whey continues to be $0.1991 per pound (initially increased from $0.1956 per pound). Finally, the...

  4. 40 CFR 144.28 - Requirements for Class I, II, and III wells authorized by rule.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... proposed test or measurement to be made; (D) The amount, size, and location (by depth) of casing to be left..., internal pressure, and axial loading; (iv) Hole size; (v) Size and grade of all casing strings; and (vi... Class III wells the owner or operator shall provide to the Director a qualitative analysis and ranges in...

  5. 40 CFR 90.410 - Engine test cycle.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine test cycle. 90.410 Section 90... Procedures § 90.410 Engine test cycle. (a) Follow the appropriate 6-mode test cycle for Class I, I-B and II engines and 2-mode test cycle for Class I-A, III, IV, and V engines when testing spark-ignition engines...

  6. The Determination of the Concentrations of Sugar Solutions by Laser Refractometry.

    ERIC Educational Resources Information Center

    Hughes, Elvin, Jr.; And Others

    1988-01-01

    Presents an easily performed experiment to determine sucrose concentrations using a laser and a hollow glass prism. The experiment is suggested for high school, freshman college, and instrumental analysis classes. Notes an Erlenmeyer flask can be used instead of a prism. (MVL)

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nurmikko, Arto V

    Synthesis of semiconductor nanomaterials by low-cost, solution-based methods is shown to lead to new classes of thin film light emitting materials. These materials have been integrated to demonstrative compact laser device testbeds to illustrate their potential for coherent emitters across the visible spectrum to disrupt established photonics technologies, particularly semiconductor lasers?

  8. Methods for correcting tilt anisoplanatism in laser-guide-star-based multiconjugate adaptive optics.

    PubMed

    Ellerbroek, B L; Rigaut, F

    2001-10-01

    Multiconjugate adaptive optics (MCAO) is a technique for correcting turbulence-induced phase distortions in three dimensions instead of two, thereby greatly expanding the corrected field of view of an adaptive optics system. This is accomplished with use of multiple deformable mirrors conjugate to distinct ranges in the atmosphere, with actuator commands computed from wave-front sensor (WFS) measurements from multiple guide stars. Laser guide stars (LGSs) must be used (at least for the forseeable future) to achieve a useful degree of sky coverage in an astronomical MCAO system. Much as a single LGS cannot be used to measure overall wave-front tilt, a constellation of multiple LGSs at a common range cannot detect tilt anisoplanatism. This error alone will significantly degrade the performance of a MCAO system based on a single tilt-only natural guide star (NGS) and multiple tilt-removed LGSs at a common altitude. We present a heuristic, low-order model for the principal source of tilt anisoplanatism that suggests four possible approaches to eliminating this defect in LGS MCAO: (i) tip/tilt measurements from multiple NGS, (ii) a solution to the LGS tilt uncertainty problem, (iii) additional higher-order WFS measurements from a single NGS, or (iv) higher-order WFS measurements from both sodium and Rayleigh LGSs at different ranges. Sample numerical results for one particular MCAO system configuration indicate that approach (ii), if feasible, would provide the highest degree of tilt anisoplanatism compensation. Approaches (i) and (iv) also provide very useful levels of performance and do not require unrealistically low levels of WFS measurement noise. For a representative set of parameters for an 8-m telescope, the additional laser power required for approach (iv) is on the order of 2 W per Rayleigh LGS.

  9. Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks.

    PubMed

    Tiossi, R; Falcão-Filho, H; Aguiar Júnior, F A; Rodrigues, R C; Mattos, M da G; Ribeiro, R F

    2010-05-01

    This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0.05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27.57 +/- 5.06 microm) than other groups (I: 11.19 +/- 2.54 microm, III: 12.88 +/- 2.93 microm, IV: 13.77 +/- 1.51 microm) (P < 0.05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58.66 +/- 14.30 microm) was significantly different from cp Ti group after diagonal section (IV: 27.51 +/- 8.28 microm) (P < 0.05). On the tightened side, no significant differences were found between groups (P > 0.05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

  10. Multipass laser amplification with near-field far-field optical separation

    DOEpatents

    Hagen, Wilhelm F.

    1979-01-01

    This invention discloses two classes of optical configurations for high power laser amplification, one allowing near-field and the other allowing far-field optical separation, for the multiple passage of laser pulses through one or more amplifiers over an open optical path. These configurations may reimage the amplifier or any other part of the cavity on itself so as to suppress laser beam intensity ripples that arise from diffraction and/or non-linear effects. The optical cavities combine the features of multiple passes, spatial filtering and optical reimaging and allow sufficient time for laser gain recovery.

  11. Use of laser photomodulation in the evolution of oral mucositis associated to cyclophosphamide, methotrexate, 5-fluouracil - CMF in 5 fluouracil + adriamycin + cyclophosphamide - FAC chemotherapy protocols in patients with breast cancer

    NASA Astrophysics Data System (ADS)

    de Fátima Lima Ferreira, Maria; de Carvalho, Fabiola Bastos; de Oliveira, Susana C. P. S.; Monteiro, Juliana S. C.; Santos, Gustavo M. P.; Gesteira, Maria F. M.; Maia, Tereza Cristina Teixeira; Pinheiro, Antônio L. B.

    2013-03-01

    The aim of this study was to evaluate the efficacy of the laser photobiomodulation (FBML) in prevention and treatment of oral mucositis induced by chemotherapy protocols CMF (cyclophosphamide, methotrexate, 5-Fluouracil) and FAC (5 Fluouracil + Adriamycin + Cyclophosphamide) in cancer patients breast. We selected 28 patients treated at the Center for High Complexity (CACON), who underwent 6 cycles of 21 days of treatment, with diagnosis of infiltrating ductal carcinoma (ICD C50.9). Were randomly divided into three groups: Group A - eight patients (Protocol FAC + Dental protocol of CACON + Laser), Group B - 6 patients (Protocol CMF + Dental protocol of CACON + Laser), Group C - was divided into two sub-groups: Group C1 with 8 patients (Control Group 1: FAC + Dental protocol o CACON) and group C2 with 6 patients (control group 2: Protocol CMF + Dental protocol of CACON). Patients in Group A and B were use of preventive FBML 24 hours before the start of chemotherapy cycle, then every 48 hours and was extended up to one week following completion of chemotherapy. The groups A and B, presented oral mucositis grade 0 (64.29%) p = 0.07, grade I (7.14%), grade II (14.29%), grade III (7.14 %), grade IV (7.14%) compared to group C, who presented mucositis grade 0 (35.71%) in the initial evaluation with p = 0.10, grade I (21.43%), grade II (28.57%), grade III (14.29%), grade IV (0.00%), patients who used the FBML as a preventive and therapeutic showed a reduction and pain relief in 42.86%. It is concluded that the low power laser when used preventively or as therapy and showed immediate relief of pain and accelerate tissue repair.

  12. Current Laser Resurfacing Technologies: A Review that Delves Beneath the Surface

    PubMed Central

    Preissig, Jason; Hamilton, Kristy; Markus, Ramsey

    2012-01-01

    Numerous laser platforms exist that rejuvenate the skin by resurfacing its upper layers. In varying degrees, these lasers improve the appearance of lentigines and rhytides, eliminate photoaging, soften scarring due to acne and other causes, and treat dyspigmentation. Five major classes of dermatologic lasers are currently in common use: ablative and nonablative lasers in both fractionated and unfractionated forms as well as radiofrequency technologies. The gentler nonablative lasers allow for quicker healing, whereas harsher ablative lasers tend to be more effective. Fractionating either laser distributes the effect, increasing the number of treatments but minimizing downtime and complications. In this review article, the authors seek to inform surgeons about the current laser platforms available, clarify the differences between them, and thereby facilitate the identification of the most appropriate laser for their practice. PMID:23904818

  13. A Novel Class of Bis- and Tris-Chelate Diam(m)inebis(dicarboxylato)platinum(IV) Complexes as Potential Anticancer Prodrugs

    PubMed Central

    Varbanov, Hristo P.; Göschl, Simone; Heffeter, Petra; Theiner, Sarah; Roller, Alexander; Jensen, Frank; Jakupec, Michael A.; Berger, Walter; Galanski, Markus; Keppler, Bernhard K.

    2015-01-01

    A novel class of platinum(IV) complexes of the type [Pt(Am)-(R(COO)2)2], where Am is a chelating diamine or two monodentate am(m)ine ligands and R(COO)2 is a chelating dicarboxylato moiety, was synthesized. For this purpose, the reaction between the corresponding tetrahydroxidoplatinum(IV) precursors and various dicarboxylic acids, such as oxalic, malonic, 3-methylmalonic, and cyclobutanedicarboxylic acid, was utilized. All new compounds were characterized in detail, using 1D and 2D NMR techniques, ESI-MS, FTIR spectroscopy, elemental analysis, TGA, and X-ray diffraction. Their in vitro cytotoxicity was determined in a panel of human tumor cell lines (CH1, SW480 and A549) by means of the MTT colorimetric assay. Furthermore, the lipophilicity and redox properties of the novel complexes were evaluated in order to better understand their pharmacological behavior. The most promising drug candidate, 4b (Pt(DACH)(mal)2), demonstrated low in vivo toxicity but profound anticancer activity against both the L1210 leukemia and CT-26 colon carcinoma models. PMID:25032896

  14. Theoretical analysis of a new class of optical bistability due to noncoherent coupling within a twin-laser system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuszelewicz, R.; Oudar, J.L.

    1987-04-01

    A new class of optical bistable devices, relying on the mutual quenching of two identical lasers, is theoretically analyzed. Conditions for achieving adequate competition between an external injected beam and the intracavity field through a noncoherent coupling (NCC) are discussed. Steady-state and transient behaviours are analyzed and lead to fast electrical or optical switching ( <100 ps ) and low commutation energy ( <10 pH). High efficiency, compactness, and technological compatibility with other integrated devices are expected. In addition, the emissive properties of these devices should considerably simplify their use in cascaded configurations.

  15. Preparation of 6-hydroxyindolines and their use for preparation of novel laser dyes

    DOEpatents

    Field, George F.; Hammond, Peter R.

    1993-01-01

    A novel method for the synthesis of 6-hydroxyindolines and new fluorescent dyes produced therefrom, which dyes are ring-constrained indoline-based rhodamine class dyes. These dyes have absorption and emission spectra which make them particularly useful in certain dye laser applications.

  16. Influence of glass-ionomer cement on the interface and setting reaction of mineral trioxide aggregate when used as a furcal repair material using laser Raman spectroscopic analysis.

    PubMed

    Nandini, Suresh; Ballal, Suma; Kandaswamy, Deivanayagam

    2007-02-01

    The prolonged setting time of mineral trioxide aggregate (MTA) is the main disadvantage of this material. This study analyzes the influence of glass-ionomer cement on the setting of MTA using laser Raman spectroscopy (LRS). Forty hollow glass molds were taken in which MTA was placed. In Group I specimens, MTA was layered with glass-ionomer cement after 45 minutes. Similar procedures were done for Groups II and III at 4 hours and 3 days, respectively. No glass ionomer was added in Group IV, which were then considered as control samples. Each sample was scanned at various time intervals. At each time interval, the interface between MTA and glass-ionomer cement was also scanned (excluding Group IV). The spectral analysis proved that placement of glass-ionomer cement over MTA after 45 minutes did not affect its setting reaction and calcium salts may be formed in the interface of these two materials.

  17. Outcome of nonsurgical intervention in patients with perforated peptic ulcers.

    PubMed

    Lay, Ping-Lien; Huang, Hsin-Hung; Chang, Wei-Kuo; Hsieh, Tsai-Yuan; Huang, Tien-Yu; Lin, Hsuan-Hwai

    2016-08-01

    Although surgical intervention is the favorable treatment modality for perforated peptic ulcer, nonsurgical treatment is another option. The aim of this study is to analyze the results of conservative treatment for perforated peptic ulcer. Between 2003 and 2014, 403 patients were admitted to our hospital for perforated peptic ulcer, and 383 patients underwent surgery, whereas 20 were allocated to conservative treatment. The results of nonsurgical intervention in these patients were analyzed retrospectively. The overall mortality rate of conservative treatment was 40%. Eleven patients remained hospitalized less than 2 weeks; among them, patients with a high (≥IV) American Society of Anesthesiologists class at admission had higher mortality than those with a low (

  18. [Clinical policy for management and risk stratification of community-acquired pneumonia in patients hospitalized on the basis of conventional admission criteria].

    PubMed

    Putinati, Stefano; Ballerin, Licia; Piattella, Marco; Ritrovato, Lucia; Zabini, Franco; Potena, Alfredo

    2003-05-01

    To identify discrepancies between Pneumonia Severity Index (PSI) risk class and the conventional criteria for deciding the site of care we performed a prospective observational study on 229 patients hospitalized for community-acquired pneumonia. PSI classes and corresponding mortality rates were as following: class I, 41 patients (0%); class II, 20 (0%); class III, 58 (1.7%); class IV, 86 (8.1%); class V, 24 (33.3%). Overall, 119 patients (52%) who were hospitalized according to conventional criteria were assigned to low-risk classes (I-III). Among these low risk patients, 58 (49%) had complications as respiratory failure, pleural effusion, hypotension or shock; among remaining patients, no reasons for admission were found. This latter group deserves prospective evaluation in randomized studies comparing in-hospital versus outpatient management.

  19. Initial Interpretation and Evaluation of a Profile-Based Classification System for the Anxiety and Mood Disorders: Incremental Validity Compared to DSM-IV Categories

    PubMed Central

    Rosellini, Anthony J.; Brown, Timothy A.

    2014-01-01

    Limitations in anxiety and mood disorder diagnostic reliability and validity due to the categorical approach to classification used by the Diagnostic and Statistical Manual of Mental Disorders (DSM) have been long recognized. Although these limitations have led researchers to forward alternative classification schemes, few have been empirically evaluated. In a sample of 1,218 outpatients with anxiety and mood disorders, the present study examined the validity of Brown and Barlow's (2009) proposal to classify the anxiety and mood disorders using an integrated dimensional-categorical approach based on transdiagnostic emotional disorder vulnerabilities and phenotypes. Latent class analyses of seven transdiagnostic dimensional indicators suggested that a six-class (i.e., profile) solution provided the best model fit and was the most conceptually interpretable. Interpretation of the classes was further supported when compared with DSM-IV diagnoses (i.e., within-class prevalence of diagnoses, using diagnoses to predict class membership). In addition, hierarchical multiple regression models were used to demonstrate the incremental validity of the profiles; class probabilities consistently accounted for unique variance in anxiety and mood disorder outcomes above and beyond DSM diagnoses. These results provide support for the potential development and utility of a hybrid dimensional-categorical profile approach to anxiety and mood disorder classification. In particular, the availability of dimensional indicators and corresponding profiles may serve as a useful complement to DSM diagnoses for both researchers and clinicians. PMID:25265416

  20. Shear bond strength and SEM morphology evaluation of different dental adhesives to enamel prepared with ER:YAG laser

    PubMed Central

    Pires, Patrícia T.; Ferreira, João C.; Oliveira, Sofia A.; Azevedo, Álvaro F.; Dias, Walter R.; Melo, Paulo R.

    2013-01-01

    Context: Early observations of enamel surfaces prepared by erbium lasers motivated clinicians to use laser as an alternative to chemical etching. Aims: Evaluate shear bond strength (SBS) values of different dental adhesives on Erbium:Yttrium Aluminum Garnet (Er:YAG) laser prepared enamel and to evaluate possible etching patterns correlations between dental adhesives and SBS values. Subjects and Methods: One hundred bovine incisors were randomly assigned to SBS tests on enamel (n = 15) and to enamel morphology analysis (n = 5) after Er:YAG laser preparation as follows: Group I – 37% phosphoric acid (PA)+ ExciTE®; Group II – ExciTE®; Group III – AdheSE® self-etching; Group IV – FuturaBond® no-rinse. NR; Group V – Xeno® V. Teeth were treated with the adhesive systems and subjected to thermal cycling. SBS were performed in a universal testing machine at 5 mm/min. Statistical Analysis Used: One-way ANOVA and post-hoc tests (P < 0.05). For the morphology evaluation, specimens were immersed in Ethylenediamine tetraacetic acid (EDTA) and the etching pattern analyzed under Scanning Electron Microscope (SEM). Results: Mean bond strengths were Group I – 47.17 ± 1.61 MPa (type I etching pattern); Group II – 32.56 ± 1.64 MPa, Group III – 29.10 ± 1.34 MPa, Group IV – 23.32 ± 1.53 MPa (type III etching pattern); Group V – 24.43 MPa ± 1.55 (type II etching pattern). Conclusions: Different adhesive systems yielded significantly different SBSs. Acid etching significantly increased the adhesion in laser treated enamel. No differences in SBS values were obtained between AdheSE® and ExciTE® without condition with PA. FuturaBond® NR and Xeno® V showed similar SBS, which was lower in comparison to the others adhesives. No correlation between enamel surface morphology and SBS values was observed, except when PA was used. PMID:23853447

  1. Pulpotomies with CO2 laser in dogs

    NASA Astrophysics Data System (ADS)

    Figueiredo, Jose A. P.; Chavantes, Maria C.; Gioso, Marco A.; Pesce, Hildeberto F.; Jatene, Adib D.

    1995-05-01

    The aim of this study was to evaluate the clinical aspects of dental pulps submitted to shallow pulpotomy followed by CO2 laser radiation at five different procedures. For this purpose, initially 66 dogs' teeth were opened and about 2 or 3 mm of coronal dental pulp was removed. Continuous irrigation with saline solution was implemented. The teeth were randomly divided into 6 groups of 11 each. After cessation of bleeding, in group I, CO2 laser (Xanar-20, USA) was irradiated for 1 second at a power of 5 watts; in group II, 2 seconds at 3 watts; in Group III, 2 seconds at 5 watts; in Group IV, 1 second at 3 watts; in Group V, a continuous mode at 3 watts; Group VI served as a control, with no laser irradiation. The results showed no clinical differences between the 3 W and 5 W powers. Time period of irradiation exposition influenced definitively the clinical appearance of the dental pulps. Groups I and IV (1 second) were unable to stop the bleeding, which persisted over 15 minutes for all teeth. This may be due to the intense heat generated by CO2 laser, causing vasodilatation. Groups II and III displayed a similar appearance, but bleeding stopped in about 10 minutes. Group V (continuous mode) had no bleeding after irradiation, but a plasma-like liquid would come out for almost 2 minutes. When comparing to the control (Group VI), all the pulps would assume a jelly-like aspect, with black granulated tissue on the surface, covering totally the pulps of Group V and partially the other groups. The histological results will be discussed in a further study. From the data obtained, it seems that CO2 laser irradiation for pulpotomies should be done in a continuous mode, for clinical convenience in terms of time taken and effective irradiation.

  2. Shear bond strength and SEM morphology evaluation of different dental adhesives to enamel prepared with ER:YAG laser.

    PubMed

    Pires, Patrícia T; Ferreira, João C; Oliveira, Sofia A; Azevedo, Alvaro F; Dias, Walter R; Melo, Paulo R

    2013-01-01

    Early observations of enamel surfaces prepared by erbium lasers motivated clinicians to use laser as an alternative to chemical etching. Evaluate shear bond strength (SBS) values of different dental adhesives on Erbium:Yttrium Aluminum Garnet (Er:YAG) laser prepared enamel and to evaluate possible etching patterns correlations between dental adhesives and SBS values. One hundred bovine incisors were randomly assigned to SBS tests on enamel (n = 15) and to enamel morphology analysis (n = 5) after Er:YAG laser preparation as follows: Group I - 37% phosphoric acid (PA)+ ExciTE(®); Group II - ExciTE(®); Group III - AdheSE(®) self-etching; Group IV - FuturaBond(®) no-rinse. NR; Group V - Xeno(®) V. Teeth were treated with the adhesive systems and subjected to thermal cycling. SBS were performed in a universal testing machine at 5 mm/min. One-way ANOVA and post-hoc tests (P < 0.05). For the morphology evaluation, specimens were immersed in Ethylenediamine tetraacetic acid (EDTA) and the etching pattern analyzed under Scanning Electron Microscope (SEM). Mean bond strengths were Group I - 47.17 ± 1.61 MPa (type I etching pattern); Group II - 32.56 ± 1.64 MPa, Group III - 29.10 ± 1.34 MPa, Group IV - 23.32 ± 1.53 MPa (type III etching pattern); Group V - 24.43 MPa ± 1.55 (type II etching pattern). Different adhesive systems yielded significantly different SBSs. Acid etching significantly increased the adhesion in laser treated enamel. No differences in SBS values were obtained between AdheSE(®) and ExciTE(®) without condition with PA. FuturaBond(®) NR and Xeno(®) V showed similar SBS, which was lower in comparison to the others adhesives. No correlation between enamel surface morphology and SBS values was observed, except when PA was used.

  3. Successful and safe use of Q-switched lasers in the treatment of nevus of Ota in children with phototypes IV-VI.

    PubMed

    Belkin, Daniel A; Jeon, Hana; Weiss, Elliot; Brauer, Jeremy A; Geronemus, Roy G

    2018-01-01

    Nevus of Ota represents congenital dermal melanocytosis in a trigeminal distribution, most commonly occurring in Asian individuals and other individuals with skin of color. Evidence suggests early treatment is beneficial. Multiple reports have shown efficacy and safety of Q-switched laser treatment in adults. There is little data on children and in non-Asian skin types. This series was done to demonstrate safe and effective use of Q-switched laser therapy in children of multiple skin types. Retrospective case series. This was a chart review of patients under 18 years old who presented to our practice from 2002 to 2015 with a clinical diagnosis of nevus of Ota who were treated with Q-switched lasers (694 and 1,064 nm). Patients were treated without the use of general anesthesia or sedation, and corneal shields were used in appropriate cases. Percentage of improvement as well as side effects were rated by five physicians independently. Improvement, when present, was rated in quartiles (1-25%, 26-50%, 51-75%, and 76-100% improvement). Twenty-four children were included. The average age at the start of treatment was 3.9 years old (range of 3 months to 12.4 years), and patients had Fitzpatrick skin types IV through VI. The mean number of treatments was 9.3. Assessment revealed excellent response (76-100% improvement) in 70% of patients and good to excellent response (51-100% improvement) in 86%. Two patients (8%) had post-inflammatory hyperpigmentation, one of whom also had focal hypopigmentation. Treatment of nevus of Ota with Q-switched lasers in children with skin of color, without general anesthesia or sedation, is safe and effective. Early intervention should be encouraged for better efficacy and to prevent psychosocial distress in later childhood and adulthood. Lasers Surg. Med. 50:56-60, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  4. Flexural strength of pure Ti, Ni-Cr and Co-Cr alloys submitted to Nd:YAG laser or TIG welding.

    PubMed

    Rocha, Rick; Pinheiro, Antônio Luiz Barbosa; Villaverde, Antonio Balbin

    2006-01-01

    Welding of metals and alloys is important to Dentistry for fabrication of dental prostheses. Several methods of soldering metals and alloys are currently used. The purpose of this study was to assess, using the flexural strength testing, the efficacy of two processes Nd:YAG laser and TIG (tungsten inert gas) for welding of pure Ti, Co-Cr and Ni-Cr alloys. Sixty cylindrical specimens were prepared (20 of each material), bisected and welded using different techniques. Four groups were formed (n=15). I: Nd:YAG laser welding; II- Nd:YAG laser welding using a filling material; III- TIG welding and IV (control): no welding (intact specimens). The specimens were tested in flexural strength and the results were analyzed statistically by one-way ANOVA. There was significant differences (p<0.001) among the non-welded materials, the Co-Cr alloy being the most resistant to deflection. Comparing the welding processes, significant differences (p<0.001) where found between TIG and laser welding and also between laser alone and laser plus filling material. In conclusion, TIG welding yielded higher flexural strength means than Nd:YAG laser welding for the tested Ti, Co-Cr and Ni-Cr alloys.

  5. A Comparison of the Effects of Intraosseous and Intravenous 5% Albumin on Infusion Time and Hemodynamic Measures in a Swine Model of Hemorrhagic Shock.

    PubMed

    Muir, Stacy L; Sheppard, Lance B; Maika-Wilson, Anne; Burgert, James M; Garcia-Blanco, Jose; Johnson, Arthur D; Coyner, Jennifer L

    2016-08-01

    Introduction Obtaining intravenous (IV) access in patients in hemorrhagic shock is often difficult and prolonged. Failed IV attempts delay life-saving treatment. Intraosseous (IO) access may often be obtained faster than IV access. Albumin (5%) is an option for prehospital volume expansion because of the absence of interference with coagulation and platelet function. Hypothesis/Problem There are limited data comparing the performance of IO and IV administered 5% albumin. The aims of this study were to compare the effects of tibial IO (TIO) and IV administration of 500 mL of 5% albumin on infusion time and hemodynamic measurements of heart rate (HR), mean arterial pressure (MAP), cardiac output (CO), and stroke volume (SV) in a swine model of hemorrhagic shock. Sixteen male swine were divided into two groups: TIO and IV. All subjects were anesthetized and a Class III hemorrhage was achieved by exsanguination of 31% of estimated blood volume (EBV) from a femoral artery catheter. Following exsanguination, 500 mL of 5% albumin was administered under pressurized infusion (300 mmHg) by the TIO or IV route and infusion time was recorded. Hemodynamic measurements of HR, MAP, CO, and SV were collected before and after exsanguination and every 20 seconds for 180 seconds during 5% albumin infusion. An independent t-test determined that IV 5% albumin infusion was significantly faster compared to IO (P=.01). Mean infusion time for TIO was seven minutes 35 seconds (SD=two minutes 44 seconds) compared to four minutes 32 seconds (SD=one minute 08 seconds) in the IV group. Multivariate Analysis of Variance was performed on hemodynamic data collected during the 5% albumin infusion. Analyses indicated there were no significant differences between the TIO and IV groups relative to MAP, CO, HR, or SV (P>.05). While significantly longer to infuse 5% albumin by the TIO route, the longer TIO infusion time may be negated as IO devices can be placed more quickly compared to repeated IV attempts. The lack of significant difference between the TIO and IV routes relative to hemodynamic measures indicate the TIO route is a viable route for the infusion of 5% albumin in a swine model of Class III hemorrhage. Muir SL , Sheppard LB , Maika-Wilson A , Burgert JM , Garcia-Blanco J , Johnson AD , Coyner JL . A comparison of the effects of intraosseous and intravenous 5% albumin on infusion time and hemodynamic measures in a swine model of hemorrhagic shock. Prehosp Disaster Med. 2016;31(4):436-442.

  6. Distribution of Trauma Care Facilities in Oman in Relation to High-Incidence Road Traffic Injury Sites: Pilot study.

    PubMed

    Al-Kindi, Sara M; Naiem, Ahmed A; Taqi, Kadhim M; Al-Gheiti, Najla M; Al-Toobi, Ikhtiyar S; Al-Busaidi, Nasra Q; Al-Harthy, Ahmed Z; Taqi, Alaa M; Ba-Alawi, Sharif A; Al-Qadhi, Hani A

    2017-11-01

    Road traffic injuries (RTIs) are considered a major public health problem worldwide. In Oman, high numbers of RTIs and RTI-related deaths are frequently registered. This study aimed to evaluate the distribution of trauma care facilities in Oman with regards to their proximity to RTI-prevalent areas. This descriptive pilot study analysed RTI data recorded in the national Royal Oman Police registry from January to December 2014. The distribution of trauma care facilities was analysed by calculating distances between areas of peak RTI incidence and the closest trauma centre using Google Earth and Google Maps software (Google Inc., Googleplex, Mountain View, California, USA). A total of 32 trauma care facilities were identified. Four facilities (12.5%) were categorised as class V trauma centres. Of the facilities in Muscat, 42.9% were ranked as class IV or V. There were no class IV or V facilities in Musandam, Al-Wusta or Al-Buraimi. General surgery, orthopaedic surgery and neurosurgery services were available in 68.8%, 59.3% and 12.5% of the centres, respectively. Emergency services were available in 75.0% of the facilities. Intensive care units were available in 11 facilities, with four located in Muscat. The mean distance between a RTI hotspot and the nearest trauma care facility was 34.7 km; however, the mean distance to the nearest class IV or V facility was 83.3 km. The distribution and quality of trauma care facilities in Oman needs modification. It is recommended that certain centres upgrade their levels of trauma care in order to reduce RTI-associated morbidity and mortality in Oman.

  7. Cost-Effectiveness of Sacubitril-Valsartan in Patients With Heart Failure With Reduced Ejection Fraction.

    PubMed

    Sandhu, Alexander T; Ollendorf, Daniel A; Chapman, Richard H; Pearson, Steven D; Heidenreich, Paul A

    2016-11-15

    Sacubitril-valsartan therapy reduces cardiovascular mortality compared with enalapril therapy in patients with heart failure with reduced ejection fraction. To evaluate the cost-effectiveness of sacubitril-valsartan versus angiotensin-converting enzyme inhibitor therapy in patients with chronic heart failure. Markov decision model. Clinical trials, observational analyses, reimbursement data from the Centers for Medicare & Medicaid Services, drug pricing databases, and Centers for Disease Control and Prevention life tables. Patients at an average age of 64 years, New York Heart Association (NYHA) class II to IV heart failure, and left ventricular ejection fraction of 0.40 or less. Lifetime. Societal. Treatment with sacubitril-valsartan or lisinopril. Life-years, quality-adjusted life-years (QALYs), costs, heart failure hospitalizations, and incremental cost-effectiveness ratios. The sacubitril-valsartan group experienced 0.08 fewer heart failure hospitalization, 0.69 additional life-year, 0.62 additional QALY, and $29 203 in incremental costs, equating to a cost per QALY gained of $47 053. The cost per QALY gained was $44 531 in patients with NYHA class II heart failure and $58 194 in those with class III or IV heart failure. Sacubitril-valsartan treatment was most sensitive to the duration of improved outcomes, with a cost per QALY gained of $120 623 if the duration was limited to the length of the trial (median, 27 months). No variations in other parameters caused the cost to exceed $100 000 per QALY gained. The benefit of sacubitril-valsartan is based on a single clinical trial. Treatment with sacubitril-valsartan provides reasonable value in reducing cardiovascular mortality and morbidity in patients with NYHA class II to IV heart failure. U.S. Department of Veterans Affairs and Institute for Clinical and Economic Review.

  8. Current Status of Study on Hydrogen Production with Space Solar Power Systems (SSPS)

    NASA Astrophysics Data System (ADS)

    Mori, M.; Kagawa, H.; Nagayama, H.; Saito, Y.

    2004-12-01

    Japan Aerospace Exploration Agency (JAXA) has been conducting studies on Space Solar Power Systems (SSPS) using microwave and laser beams for years since FY1998 organizing a special committee and working groups. The microwave based SSPS are huge solar power systems that generate GW power by solar cells. The electric power is transmitted via microwave from the SSPS to the ground. In the laser based SSPS, a solar condenser equipped with lenses or mirrors and laser-generator would be put into orbit. A laser beam would be sent to Earth-based hydrogen generating device. We are proposing a roadmap that consists of a stepwise approach to achieve commercial SSPS in 20-30 years. The first step is 50kW class Technology Demonstration Satellite to demonstrate microwave power transmission. The second step is to demonstrate robotic assembly of 10MW class large scale flexible structure in space on ISS co-orbit. The third step is to build a prototype SSPS in GEO. The final step is to build commercial SSPS in GEO. We continue the study of SSPS concepts and architectures, technology flight demonstration and major technology development. System design of tens of kW class Technology Demonstration Satellite and conceptual study of 10MW class demonstration system on ISS co-orbit are also conducted. Several key technologies which are needed to be developed in appropriate R&D roadmap, such as high-voltage solar cell array, fiber type of direct solar pumping solid-state laser, high efficiency magnetron, thermal control technology and control technology of large scale flexible structure etc. are also investigated. In the study of concept design of commercial SSPS mentioned above, we have studied some configurations of both microwave based SSPS and laser based SSPS. In case of microwave based SSPS, the solar energy must be converted to electricity and then converted to a microwave beam. The on-ground rectifying antenna will collect the microwave beam and convert it to electricity to connect to commercial power grids. From the past experiences of the conceptual design of the1GW class SSPS, it is clear that system with the mirrors and modularized unit which integrated solar cells and microwave power transmitters is promising. In this type of SSPS, the solar lights are directed to the energy conversion unit integrated solar cells and microwave power transmitters using mirrors. The key factor in designing systems is feasibility of thermal system. Considering above these factors, some reference models are being considered now. FY2003 reference model is the model for formation flight without the center truss which connect to primary mirrors to energy conversion unit. Using this model as basis, we are carrying out examination from various viewpoints aiming at the cost minimum to build and maintain the systems. In case of laser based SSPS, the laser beam would be directly produced from the solar light using the direct solar pumping solid-state laser device. This laser beams would be collected on ground and used to produce hydrogen from seawater. The receiving / energy conversion station is settled on an ocean, and producing hydrogen can be stored and transported by ships to consumers. In designing laser based SSPS, conversion efficiency of the direct solar pumping solid-state laser and feasibility of thermal system are critical factors. Since magnification of solar concentrator is very high, improvement of thermal control system is important. Feasibility of its ground facilities and production technology of hydrogen using laser beams has been also studied. Both hydrogen generating systems with photo-catalyst device and electrolytic ones have been examined. From the past experiences of this study, high efficient electric power generating technology using the solar cell which suited the wavelength of laser is promising. The life cycle cost model of laser based SSPS was created and evaluated its validity. Sensitivity analysis of laser based SSPS are also continued aiming at hydrogen generating cost of around 20 cent per Nm3 . This paper presents a summary of studies on SSPS that JAXA has examined.

  9. The image of motor units architecture in the mechanomyographic signal during the single motor unit contraction: in vivo and simulation study.

    PubMed

    Kaczmarek, P; Celichowski, J; Drzymała-Celichowska, H; Kasiński, A

    2009-08-01

    The mechanomyographic (MMG) signal analysis has been performed during single motor unit (MU) contractions of the rat medial gastrocnemius muscle. The MMG has been recorded as a muscle surface displacement by using a laser distance sensor. The profiles of the MMG signal let to categorize these signals for particular MUs into three classes. Class MMG-P (positive) comprises MUs with the MMG signal similar to the force signal profile, where the distance between the muscle surface and the laser sensor increases with the force increase. The class MMG-N (negative) has also the MMG profile similar to the force profile, however the MMG is inverted in comparison to the force signal and the distance measured by using laser sensor decreases with the force increase. The third class MMG-M (mixed) characterize the MMG which initially increases with the force increases and when the force exceeds some level it starts to decrease towards the negative values. The semi-pennate muscle model has been proposed, enabling estimation of the MMG generated by a single MU depending on its localization. The analysis have shown that in the semi-pennate muscle the localization of the MU and the relative position of the laser distance sensor determine the MMG profile and amplitude. Thus, proposed classification of the MMG recordings is not related to the physiological types of MUs, but only to the MU localization and mentioned sensor position. When the distance sensor is located over the middle of the muscle belly, a part of the muscle fibers have endings near the location of the sensor beam. For the MU MMG of class MMG-N the deflection of the muscle surface proximal to the sensor mainly influences the MMG recording, whereas for the MU MMG class MMG-P, it is mainly the distal muscle surface deformation. For the MU MMG of MMG-M type the effects of deformation within the proximal and distal muscle surfaces overlap. The model has been verified with experimental recordings, and its responses are consistent and adequate in comparison to the experimental data.

  10. International Free Electron Laser Conference (15th) Held in The Hague, Netherland on August 23-27, 1993. Book of Abstracts

    DTIC Science & Technology

    1993-08-27

    University, Korea Mo3-23 Two Color FEL Complex Based on High Current Race - Track Microtron E.B. Gaskevich, A.I. Karev, V.G. Kurakin Lebedev Institute...Free Electron Laser Using Race - Track Microtron -Recuperator GI. Erg, N.G. Gavrilov, El. Gorniker, G.N. Kulipanov, I.V. Kuptsov, G.Ya. Kurkin, A.D...FEL COMPLEX BASED ON HIGH CURRENT RACE - TRACK MICROTRON a.kejich, A.I.Karev, V.G.Kurakin Department of High Energy Physics, Lebedev Physical Institute

  11. Infrared and Terahertz Lasers on SI Using Novel Group-IV Alloys

    DTIC Science & Technology

    2011-11-30

    gain at 2,883 nm is comparable with those of many conventional III-V semiconductor lasers. On the other hand, a waveguide design was also presented ...other conduction-band valleys (", X) are above the L-valley band edge of the Ge0.76Si0.19Sn0.05 barrier. This band alignment presents a desirable...the QCL structure based upon Ge/ Ge0.76Si0.19Sn0.05 QWs. Only L-valley conduction- band lineups are shown in the potential diagram under an applied

  12. IV-VI compound midinfrared high-reflectivity mirrors and vertical-cavity surface-emitting lasers grown by molecular-beam epitaxy

    NASA Astrophysics Data System (ADS)

    Shi, Z.; Xu, G.; McCann, P. J.; Fang, X. M.; Dai, N.; Felix, C. L.; Bewley, W. W.; Vurgaftman, I.; Meyer, J. R.

    2000-06-01

    Midinfrared broadband high-reflectivity Pb1-xSrxSe/BaF2 distributed Bragg reflectors and vertical-cavity surface-emitting lasers (VCSELs) with PbSe as the active material were grown by molecular-beam epitaxy. Because of an extremely high index contrast, mirrors with only three quarter-wave layer pairs had reflectivities exceeding 99%. For pulsed optical pumping, a lead salt VCSEL emitting at the cavity wavelength of 4.5-4.6 μm operated nearly to room temperature (289 K).

  13. Lasant Materials for Blackbody-Pumped Lasers

    NASA Technical Reports Server (NTRS)

    Deyoung, R. J. (Editor); Chen, K. Y. (Editor)

    1985-01-01

    Blackbody-pumped solar lasers are proposed to convert sunlight into laser power to provide future space power and propulsion needs. There are two classes of blackbody-pumped lasers. The direct cavity-pumped system in which the lasant molecule is vibrationally excited by the absorption of blackbody radiation and laser, all within the blackbody cavity. The other system is the transfer blackbody-pumped laser in which an absorbing molecule is first excited within the blackbody cavity, then transferred into a laser cavity when an appropriate lasant molecule is mixed. Collisional transfer of vibrational excitation from the absorbing to the lasing molecule results in laser emission. A workshop was held at NASA Langley Research Center to investigate new lasant materials for both of these blackbody systems. Emphasis was placed on the physics of molecular systems which would be appropriate for blackbody-pumped lasers.

  14. Commissioning of a kW-class nanosecond pulsed DPSSL operating at 105 J, 10 Hz

    NASA Astrophysics Data System (ADS)

    Mason, Paul; Divoký, Martin; Butcher, Thomas; Pilař, Jan; Ertel, Klaus; Hanuš, Martin; De Vido, Mariastefania; Banerjee, Saumyabrata; Phillips, Jonathan; Smith, Jodie; Hollingham, Ian; Muresan, Mihai-George; Landowski, Brian; Suarez-Merchan, Jorge; Thomas, Adrian; Dominey, Mark; Benson, Luke; Lintern, Andrew; Costello, Billy; Tomlinson, Stephanie; Blake, Steve; Tyldesley, Mike; Lucianetti, Antonio; Hernandez-Gomez, Cristina; Edwards, Chris; Mocek, Tomas; Collier, John

    2017-05-01

    In this paper we present details of the commissioning of DiPOLE100, a kW-class nanosecond pulsed diode pumped solid state laser (DPSSL), at the HiLASE Centre at Dolní Břežany in the Czech Republic. The laser system, built at the Central Laser Facility (CLF), was dismantled, packaged, shipped and reassembled at HiLASE over a 12 month period by a collaborative team from the CLF and HiLASE. First operation of the laser at the end of 2016 demonstrated amplification of 10 ns pulses at 10 Hz pulse repetition rate to an energy of 105 J at 1029.5 nm, representing the world's first kW average power, high-energy, nanosecond pulsed DPSSL. To date DiPOLE100 has been operated for over 2.5 hours at energies in excess of 100 J at 10 Hz, corresponding to nearly 105 shots, and has demonstrated long term energy stability of less than 1% RMS for continuous operation over 1 hour. This confirms the power scalability of multislab cryogenic gas-cooled amplifier technology and demonstrates its potential as a laser driver for next generation scientific, industrial, and medical applications.

  15. Institutional Research, Fiscal Year 1977: Report on Publicity Activities. Research Monograph IV.

    ERIC Educational Resources Information Center

    South Oklahoma City Junior Coll., OK.

    During the first week of December, a 10% random sample of day classes and a 10% sample of night classes at South Oklahoma City Junior College were given a questionnaire dealing with the publicity activities used prior to and during the fall 1976 enrollment period. A total of 314 students responded, 179 night and 135 day students. Day students were…

  16. Preparation of 6-hydroxyindolines and their use for preparation of novel laser dyes

    DOEpatents

    Field, G.F.; Hammond, P.R.

    1993-10-26

    A novel method is described for the synthesis of 6-hydroxyindolines and new fluorescent dyes produced therefrom, which dyes are ring-constrained indoline-based rhodamine class dyes. These dyes have absorption and emission spectra which make them particularly useful in certain dye laser applications.

  17. Convenient Microscale Synthesis of a Coumarin Laser Dye Analog

    ERIC Educational Resources Information Center

    Aktoudianakis, Evangelos; Dicks, Andrew P.

    2006-01-01

    Coumarin (2H-1-benzopyran-2-one) and its derivatives constitute a fascinating class of organic substances that are utilized industrially in areas such as cosmetics, food preservatives, insecticides and fluorescent laser dyes. The product can be synthesized, purified, and characterized within two hours with benefits of microscale reactivity being…

  18. Microleakage of Self-Etch Adhesive System in Class V Cavities Prepared by Using Er:YAG Laser with Different Pulse Modes.

    PubMed

    Phanombualert, Jutipond; Chimtim, Pijitta; Heebthamai, Thitirat; Weera-Archakul, Wilawan

    2015-09-01

    In vitro studies evaluated cementum surface morphology and microleakage of three different energy density parameters of Erbium: Yttrium Aluminum Garnet (Er:YAG) laser compared with diamond bur preparation on class V cavities with self-etch adhesive system and composite resin restoration. Standard class V cavities were prepared at cervical area below the cementoenamel junction (CEJ) in 80 extracted premolars, by using a diamond bur on the buccal surface. All teeth were randomly allocated into four groups: Group 1, diamond bur; Group 2, Er:YAG 50 mJ/15 Hz, 3.77 J/cm(2); Group 3, Er:YAG 75 mJ/15 Hz, 5.65 J/cm(2); and Group 4, Er:YAG 100 mJ/15 Hz, 7.53 J/cm(2). Five cavities from each group were evaluated by scanning electron microscopy (SEM). The 15 remaining cavities from each group were restored with self-etch adhesive and nano-hybrid composite. After thermocycling, all sample teeth were immersed in 0.2% methylene blue dye and sectioned buccolingually. Statistics were analyzed using the one way ANOVA and Mann-Whitney U tests with Bonferroni correction. The morphology showed micro-irregularities in the cementum surface of the laser group with the absence of a smear layer. The microstructure characteristics were increased surface roughness followed by increasing laser energy transmission. The Er:YAG laser groups were statistically significant, with less microleakage than the diamond bur group (p<0.05). There was statistically significant difference between the occlusal and gingival microleakage in all the groups (p<0.05). When the laser groups were compared, the lowest microleakage was achieved with energy density at 3.77 J/cm(2) on the occlusal and gingival cementum margin, which showed less microleakage than at energy densities of 5.65 and 7.53 J/cm(2) with Er:YAG laser. These observations indicate that the micro-irregularities of the cementum surface could facilitate the formation of a hybridization zone with a self-etch adhesive system. Therefore, the microleakage of Er:YAG laser irradiation was significantly decreased compared with diamond bur cavities.

  19. Vacuum suppression of acousto-optic self-modulation in a broad-area Nd-doped yttrium-aluminum-garnet single-shot laser

    NASA Astrophysics Data System (ADS)

    Rus, M. Odín Soler; Cabrera-Granado, E.; Guerra Pérez, J. M.

    2013-07-01

    We report on the origin of an acousto-optic Raman-Nath self-modulation found in a broad-area Nd:YAG single-shot laser. Operating the laser device under vacuum conditions suppresses the spectral splitting associated with acousto-optic modulation by the shock waves produced by the discharge of the pumping flash lamps. This splitting is reproduced by a general class B laser model that takes into account the dynamical density grating generated by a stationary acoustic radial wave.

  20. Tri-city study of Ecstasy use problems: a latent class analysis.

    PubMed

    Scheier, Lawrence M; Ben Abdallah, Arbi; Inciardi, James A; Copeland, Jan; Cottler, Linda B

    2008-12-01

    This study used latent class analysis to examine distinctive subtypes of Ecstasy users based on 24 abuse and dependence symptoms underlying standard DSM-IV criteria. Data came from a three site, population-based, epidemiological study to examine diagnostic nosology for Ecstasy use. Subject inclusion criteria included lifetime Ecstasy use exceeding five times and once in the past year, with participants ranging in age between 16 and 47 years of age from St. Louis, Miami, U.S. and Sydney, Australia. A satisfactory model typified four latent classes representing clearly differentiated diagnostic clusters including: (1) a group of sub-threshold users endorsing few abuse and dependence symptoms (negatives), (2) a group of 'diagnostic orphans' who had characteristic features of dependence for a select group of symptoms (mild dependent), (3) a 'transitional group' mimicking the orphans with regard to their profile of dependence also but reporting some abuse symptoms (moderate dependent), and (4) a 'severe dependent' group with a distinct profile of abuse and dependence symptoms. A multinomial logistic regression model indicated that certain latent classes showed unique associations with external non-diagnostic markers. Controlling for demographic characteristics and lifetime quantity of Ecstasy pill use, criminal behavior and motivational cues for Ecstasy use were the most efficient predictors of cluster membership. This study reinforces the heuristic utility of DSM-IV criteria applied to Ecstasy but with a different collage of symptoms that produced four distinct classes of Ecstasy users.

  1. 40 CFR 205.155 - Motorcycle class and manufacturer abbreviation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... separate combinations of the following parameters: (1) Engine type: (i) Gasoline—two stroke. (ii) Gasoline—four stroke. (iii) Gasoline—rotary. (iv) Other. (2) Engine displacement. (3) Engine configuration: (i...

  2. 40 CFR 205.155 - Motorcycle class and manufacturer abbreviation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... separate combinations of the following parameters: (1) Engine type: (i) Gasoline—two stroke. (ii) Gasoline—four stroke. (iii) Gasoline—rotary. (iv) Other. (2) Engine displacement. (3) Engine configuration: (i...

  3. 40 CFR 205.155 - Motorcycle class and manufacturer abbreviation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... separate combinations of the following parameters: (1) Engine type: (i) Gasoline—two stroke. (ii) Gasoline—four stroke. (iii) Gasoline—rotary. (iv) Other. (2) Engine displacement. (3) Engine configuration: (i...

  4. 40 CFR 205.155 - Motorcycle class and manufacturer abbreviation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... separate combinations of the following parameters: (1) Engine type: (i) Gasoline—two stroke. (ii) Gasoline—four stroke. (iii) Gasoline—rotary. (iv) Other. (2) Engine displacement. (3) Engine configuration: (i...

  5. 40 CFR 205.155 - Motorcycle class and manufacturer abbreviation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... separate combinations of the following parameters: (1) Engine type: (i) Gasoline—two stroke. (ii) Gasoline—four stroke. (iii) Gasoline—rotary. (iv) Other. (2) Engine displacement. (3) Engine configuration: (i...

  6. 21 CFR 520.1780 - Pimobendan.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... severe (modified New York Heart Association Class II, III, or IV) congestive heart failure due to... heart failure as appropriate on a case-by-case basis. (3) Limitations. Federal law restricts this drug...

  7. 21 CFR 520.1780 - Pimobendan.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... severe (modified New York Heart Association Class II, III, or IV) congestive heart failure due to... heart failure as appropriate on a case-by-case basis. (3) Limitations. Federal law restricts this drug...

  8. 21 CFR 520.1780 - Pimobendan.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... severe (modified New York Heart Association Class II, III, or IV) congestive heart failure due to... heart failure as appropriate on a case-by-case basis. (3) Limitations. Federal law restricts this drug...

  9. 21 CFR 520.1780 - Pimobendan.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... severe (modified New York Heart Association Class II, III, or IV) congestive heart failure due to... heart failure as appropriate on a case-by-case basis. (3) Limitations. Federal law restricts this drug...

  10. 21 CFR 520.1780 - Pimobendan.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... severe (modified New York Heart Association Class II, III, or IV) congestive heart failure due to... heart failure as appropriate on a case-by-case basis. (3) Limitations. Federal law restricts this drug...

  11. Spatio-temporal Theory of Lasing Action in Optically-Pumped Rotationally Excited Molecular Gases

    DTIC Science & Technology

    2011-04-11

    17. A. E. Siegman , Lasers (Univ. Science Books, 1986). 18. R. Bansal (ed.), Handbook of Engineering Electromagnetics (Marcel Dekker, Inc., 2004). 19... laser emission from optically-pumped rota- tionally excited molecular gases confined in a metallic cavity. To this end, we have developed a...the operation of this class of lasers . The effect on the main lasing features of the spatial variation of the electric field intensity and the ohmic

  12. 42 CFR 416.195 - Determination of membership in new classes of new technology IOLs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Reduced risk of intraoperative or postoperative complication or trauma; (ii) Accelerated postoperative recovery; (iii) Reduced induced astigmatism; (iv) Improved postoperative visual acuity; (v) More stable...

  13. 42 CFR 416.195 - Determination of membership in new classes of new technology IOLs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Reduced risk of intraoperative or postoperative complication or trauma; (ii) Accelerated postoperative recovery; (iii) Reduced induced astigmatism; (iv) Improved postoperative visual acuity; (v) More stable...

  14. Solar-pumped 80 W laser irradiated by a Fresnel lens.

    PubMed

    Ohkubo, Tomomasa; Yabe, Takashi; Yoshida, Kunio; Uchida, Shigeaki; Funatsu, Takayuki; Bagheri, Behgol; Oishi, Takehiro; Daito, Kazuya; Ishioka, Manabu; Nakayama, Yuichirou; Yasunaga, Norihito; Kido, Kouichirou; Sato, Yuji; Baasandash, Choijil; Kato, Kiyoshi; Yanagitani, Takagimi; Okamoto, Yoshiaki

    2009-01-15

    A solar-pumped 100 W class laser that features high efficiency and low cost owing to the use of a Fresnel lens and a chromium codoped neodymium YAG ceramic laser medium was developed. A laser output of about 80 W was achieved with combination of a 4 m(2) Fresnel lens and a pumping cavity as a secondary power concentrator. This output corresponds to 4.3% of conversion efficiency from solar power into laser, and the maximum output from a unit area of Fresnel lens was 20 W/m(2), which is 2.8 times larger than previous results with mirror-type concentrator.

  15. Psychological Effects of Chemical Defense Ensemble Imposed Heat Stress on Army Aviators

    DTIC Science & Technology

    1982-11-01

    INTRODUCTION Army aviation is currently increasing its emphasis on Chemical Defense (CD) training . In fact, Interim Change 101 (23 Dec 1981) to the...Aircrew Training Manual (TC 1-135) makes ir-flight training in full Mission Oriented Protective Posture (MOPP) IV mandatory. Training in MOPP IV will...Wing Class and had similar training and flight histories. All were acclimaite1d to the 2ocal environment, in good physical condition, and between the

  16. Biologic Disease-modifying Antirheumatic Drug (bDMARD)-induced Neutropenia: A Registry from a Retrospective Cohort of Patients with Rheumatic Diseases Treated with 3 Classes of Intravenous bDMARD.

    PubMed

    Espinoza, Francisco; Le Blay, Pierre; Combe, Bernard

    2017-06-01

    To examine the rate, risks factors, and consequences of neutropenia induced by intravenous (IV) biologic disease-modifying antirheumatic drugs (bDMARD). We conducted a retrospective cohort study in 499 patients with rheumatic diseases treated by IV abatacept (ABA), infliximab (IFX), or tocilizumab (TCZ). Rheumatoid arthritis (RA) was the most frequent diagnosis (72%). Fifty-two patients (10.4%) experienced at least 1 episode of neutropenia. No episodes of grade 4 neutropenia were documented. TCZ was more frequently related to neutropenia than ABA or IFX (18.6% vs 3.8% and 2.8%, respectively, p < 0.001). The following factors were identified as predictors of experiencing neutropenia with IV bDMARD: history of neutropenia with methotrexate (MTX; synthetic DMARD; OR 1.56, 95% CI 1.17-7.14), concomitant treatment by MTX (OR 1.21, 95% CI 1.01-2.64), and TCZ treatment (OR 2.72, 95% CI 1.53-9.05). Patients experiencing a TCZ-induced neutropenia did not show a higher risk of severe infections; however, this group had a shorter drug survival (9 mos vs 20 mos, p < 0.02) compared with TCZ patients without neutropenia. Among 3 different classes of IV bDMARD, TCZ is associated with the higher risk of neutropenia. No increased frequency of infection episodes was documented in this group.

  17. Minimizing shrinkage of interdental papilla height when treating multiple Miller Class III gingival recession defects.

    PubMed

    Mahn, Douglas H

    2015-04-01

    Miller Class III and IV gingival recession defects have interdental bone and soft-tissue loss that limit root coverage. Given the importance of the interdental papilla, protecting the integrity of this structure would seem prudent. Tunnel techniques have been successfully used to protect the interdental papilla. This article discusses the results of two cases in which multiple Miller Class III gingival recession defects were treated using tunnel-grafting techniques and an acellular dermal matrix. In both cases, root coverage was achieved while protecting the interdental papilla height.

  18. Multipulse nanosecond laser irradiation of silicon for the investigation of surface morphology and photoelectric properties

    NASA Astrophysics Data System (ADS)

    Sardar, Maryam; Chen, Jun; Ullah, Zaka; Jelani, Mohsan; Tabassum, Aasma; Cheng, Ju; Sun, Yuxiang; Lu, Jian

    2017-12-01

    We irradiate the single crystal boron-doped silicon (Si) with different number of laser pulses at constant fluence (7.5 J cm-2) in ambient air using Nd:YAG laser and examine its surface morphology and photoelectric properties in details. The results obtained from optical micrographs reveal the increase in heat affected zone (HAZ) and melted area of laser irradiated Si with increasing number of laser pulses. The SEM micrographs evidence the formation of various surface morphologies like laser induced periodic surface structures, crater, microcracks, clusters, cavities, pores, trapped bubbles, nucleation sites, micro-bumps, redeposited material and micro- and nano-particles on the surface of irradiated Si. The surface profilometry analysis informs that the depth of crater is increased with increase in number of incident laser pulses. The spectroscopic ellipsometry reveals that the multipulse irradiation of Si changes its optical properties (refractive index and extinction coefficient). The current-voltage (I-V) characteristic curves of laser irradiated Si show that although the multipulse laser irradiation produces considerable number of surface defects and damages, the electrical properties of Si are well sustained after the multipulse irradiation. The current findings suggest that the multipulse irradiation can be an effective way to tune the optical properties of Si for the fabrication of wide range of optoelectronic devices.

  19. Q-Switched 660-nm Versus 532-nm Nd: YAG Laser for the Treatment for Facial Lentigines in Asian Patients: A Prospective, Randomized, Double-Blinded, Split-Face Comparison Pilot Study.

    PubMed

    Noh, Tai Kyung; Chung, Bo Young; Yeo, Un Cheol; Chang, SeoYoun; Lee, Mi Woo; Chang, Sung Eun

    2015-12-01

    Q-switched (QS) 532-nm lasers are widely used to treat solar lentigines. To compare the efficacy and safety of 660-nm and 532-nm QS neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers in the treatment for lentigines in Asians. The halves of each face (randomly chosen) of 8 Korean Fitzpatrick Skin Type III-IV women with facial solar lentigines were treated with either 660-nm or 532-nm lasers. Pigmentation was measured objectively using a profilometric skin analysis tool and subjectively using the pigmentation area and severity index (PSI) score, global assessment of the aesthetic improvement scale (GAIS), and a patient satisfaction score at Weeks 4 and 8. Seven patients completed the study. No significant differences were found in the PSI, GAIS, patient satisfaction score, and melanin average score between the lasers. The melanin average level was significantly reduced by the 660-nm laser but not the 532-nm laser at Week 8 compared with the baseline. Both 660-nm and 532-nm QS Nd:YAG lasers effectively reduce pigmentation for up to 8 weeks with high patient satisfaction. The new 660-nm laser therefore increases the treatment options for lentigines in Asian skin.

  20. "Defense-in-Depth" Laser Safety and the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, J J

    The National Ignition Facility (NIF) is the largest and most energetic laser in the world contained in a complex the size of a football stadium. From the initial laser pulse, provided by telecommunication style infrared nanoJoule pulsed lasers, to the final 192 laser beams (1.8 Mega Joules total energy in the ultraviolet) converging on a target the size of a pencil eraser, laser safety is of paramount concern. In addition to this, there are numerous high-powered (Class 3B and 4) diagnostic lasers in use that can potentially send their laser radiation travelling throughout the facility. With individual beam paths ofmore » up to 1500 meters and a workforce of more than one thousand, the potential for exposure is significant. Simple laser safety practices utilized in typical laser labs just don't apply. To mitigate these hazards, NIF incorporates a multi layered approach to laser safety or 'Defense in Depth.' Most typical high-powered laser operations are contained and controlled within a single room using relatively simplistic controls to protect both the worker and the public. Laser workers are trained, use a standard operating procedure, and are required to wear Personal Protective Equipment (PPE) such as Laser Protective Eyewear (LPE) if the system is not fully enclosed. Non-workers are protected by means of posting the room with a warning sign and a flashing light. In the best of cases, a Safety Interlock System (SIS) will be employed which will 'safe' the laser in the case of unauthorized access. This type of laser operation is relatively easy to employ and manage. As the operation becomes more complex, higher levels of control are required to ensure personnel safety. Examples requiring enhanced controls are outdoor and multi-room laser operations. At the NIF there are 192 beam lines and numerous other Class 4 diagnostic lasers that can potentially deliver their hazardous energy to locations far from the laser source. This presents a serious and complex potential hazard to personnel. Because of this, a multilayered approach to safety is taken. This paper presents the philosophy and approach taken at the NIF in the multi-layered 'defense-in-depth' approach to laser safety.« less

  1. Color-color diagrams in near infrared: (J-H)/(H-K). I

    NASA Astrophysics Data System (ADS)

    Gyulbudaghian, Armen L.; Baloian, N.; Sanchez, I. A.

    2017-12-01

    In the paper are presented the color-color diagrams (J-H)/(H-K) for all stars with visible values B<11, for which in the known catalogs the values of J, H, K, and also spectral classes and luminosity classes of these stars are given. The diagrams are constructed for luminosity classes Ia, Ib, II, III, IV, V. The similarity of diagrams for classes Ia and Ib (super giants) and II (giants), is obvious from these diagrams. The diagrams obtained by us can be used for discovering of new young stars and also for determining of color excesses of investigating stars. Maximal amounts of stars are registered in the classes V and III. There is a tendency of increasing of J-H and H-K along the sequence of spectral classes O - M, which is correct for all luminosity classes.

  2. Perceived psychological pressure at work, social class, and risk of stroke: a 30-year follow-up in Copenhagen male study.

    PubMed

    Suadicani, Poul; Andersen, Lars L; Holtermann, Andreas; Mortensen, Ole S; Gyntelberg, Finn

    2011-12-01

    Investigate if the association between perceived psychological work pressure and risk of stroke is modified by socioeconomic status. Thirty-year follow-up of 4943 middle-aged men without cardiovascular disease. In the higher social classes (I, II, and III), perceived regular exposure to psychological work pressure was common and a significant predictor of stroke; almost 10% of the stroke events could be attributed to this exposure in the higher social classes; among lower social classes (IV and V), perceived psychological pressure was no predictor at all. Regular psychological work pressure is a highly prevalent and independent risk factor for stroke among men in higher social classes. In contrast, no association to stroke risk was found among low social class men.

  3. Bibliography of Soviet Laser Developments, Number 47, May - June 1980.

    DTIC Science & Technology

    1981-04-09

    23 p. (KL, 19/80, 17050) 99 IV. SOURCE ABBREVIATIONS (CIRC Codens) APP (A) (ATPLB) Acta physica polonica BAPS (BAPTA) Bulletin de l’Academie Polonaise...obraztsy, tovarnyye znaki PSS (PSSAB) Physica Status Solidi (A). Applied Research PTE (PRTEA) Pribory i tekhnika eksperimenta RiE (RAELA) Radiotekhnika i

  4. Bipolar Cascade Vertical-Cavity Surface-Emitting Lasers for RF Photonic Link Applications

    DTIC Science & Technology

    2007-09-01

    6 IV Current versus Voltage . . . . . . . . . . . . . . . . . . . . . 7 MBE Molecular Beam Epitaxy ...of carrying maximum photocur- rent. Numerous material parameters have been studied. Growth parameters for molecular beam epitaxy (MBE), metal-organic...12 MOCVD Metal-Organic Chemical Vapor Deposition . . . . . . . . . . 12 CBE Chemical Beam Epitaxy . . . . . . . . . . . . . . . . . . . . 12 LPE

  5. A stable Fe{sup III}-Fe{sup IV} replacement of tyrosyl radical in a class I ribonucleotide reductase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voevodskaya, N.; Lendzian, F.; Graeslund, A.

    2005-05-20

    Ribonucleotide reductase (RNR) of Chlamydia trachomatis is a class I RNR enzyme composed of two homodimeric components, proteins R1 and R2. In class I RNR, R1 has the substrate binding site, whereas R2 has a diferric site and normally in its active form a stable tyrosyl free radical. C. trachomatis RNR is unusual, because its R2 component has a phenylalanine in the place of the radical carrier tyrosine. Replacing the tyrosyl radical, a paramagnetic Fe{sup III}-Fe{sup IV} species (species X, normally a transient intermediate in the process leading to radical formation) may provide the oxidation equivalent needed to start themore » catalytic process via long range electron transfer from the active site in R1. Here EPR spectroscopy shows that in C. trachomatis RNR, species X can become essentially stable when formed in a complete RNR (R1/R2/substrate) complex, adding further weight to the possible role of this species X in the catalytic reaction.« less

  6. Method for adhesion of metal films to ceramics

    DOEpatents

    Lowndes, Douglas H.; Pedraza, Anthony J.; DeSilva, Melvin J.; Kumar, Rajagopalan A.

    1997-01-01

    Methods for making strongly bonded metal-ceramic materials. The methods include irradiating a portion of the surface of the ceramic material with a pulsed ultraviolet laser having an energy density sufficient to effect activation of the irradiated surface of the ceramic material so that adhesion of metals subsequently deposited onto the irradiated surface is substantially increased. Advantages of the invention include (i) the need for only a small number of laser pulses at relatively low focused energy density, (ii) a smoother substrate surface, (iii) activation of the laser-treated surface which provides a chemical bond between the surface and a metal deposited thereon, (iv) only low temperature annealing is required to produce the strong metal-ceramic bond; (v) the ability to obtain strong adhesion between ceramic materials and oxidation resistant metals; (vi) ability to store the laser treated ceramic materials for later deposition of metals thereon.

  7. Approaches toward a blue semiconductor laser

    NASA Technical Reports Server (NTRS)

    Ladany, I.

    1989-01-01

    Possible approaches for obtaining semiconductor diode laser action in the blue region of the spectrum are surveyed. A discussion of diode lasers is included along with a review of the current status of visible emitters, presently limited to 670 nm. Methods are discussed for shifting laser emission toward shorter wavelengths, including the use of II-IV materials, the increase in the bandgap of III-V materials by addition of nitrogen, and changing the bandstructure from indirect to direct by incorporating interstitial atoms or by constructing superlattices. Non-pn-junction injection methods are surveyed, including avalanche breakdown, Langmuir-Blodgett diodes, heterostructures, carrier accumulation, and Berglund diodes. Prospects of inventing new multinary semiconducting materials are discussed, and a number of novel materials described in the literature are tabulated. New approaches available through the development of quantum wells and superlattices are described, including resonant tunneling and the synthesis of arbitrary bandgap materials through multiple quantum wells.

  8. Method for adhesion of metal films to ceramics

    DOEpatents

    Lowndes, D.H.; Pedraza, A.J.; DeSilva, M.J.; Kumar, R.A.

    1997-12-30

    Methods for making strongly bonded metal-ceramic materials are disclosed. The methods include irradiating a portion of the surface of the ceramic material with a pulsed ultraviolet laser having an energy density sufficient to effect activation of the irradiated surface of the ceramic material so that adhesion of metals subsequently deposited onto the irradiated surface is substantially increased. Advantages of the invention include (i) the need for only a small number of laser pulses at relatively low focused energy density, (ii) a smoother substrate surface, (iii) activation of the laser-treated surface which provides a chemical bond between the surface and a metal deposited thereon, (iv) only low temperature annealing is required to produce the strong metal-ceramic bond; (v) the ability to obtain strong adhesion between ceramic materials and oxidation resistant metals; (vi) ability to store the laser treated ceramic materials for later deposition of metals thereon. 7 figs.

  9. Evaluation of laser-driven ion energies for fusion fast-ignition research

    NASA Astrophysics Data System (ADS)

    Tosaki, S.; Yogo, A.; Koga, K.; Okamoto, K.; Shokita, S.; Morace, A.; Arikawa, Y.; Fujioka, S.; Nakai, M.; Shiraga, H.; Azechi, H.; Nishimura, H.

    2017-10-01

    We investigate laser-driven ion acceleration using kJ-class picosecond (ps) laser pulses as a fundamental study for ion-assisted fusion fast ignition, using a newly developed Thomson-parabola ion spectrometer (TPIS). The TPIS has a space- and weight-saving design, considering its use in an laser-irradiation chamber in which 12 beams of fuel implosion laser are incident, and, at the same time, demonstrates sufficient performance with its detectable range and resolution of the ion energy required for fast-ignition research. As a fundamental study on laser-ion acceleration using a ps pulse laser, we show proton acceleration up to 40 MeV at 1 × 10^{19} W cm^{-2}. The energy conversion efficiency from the incident laser into protons higher than 6 MeV is 4.6%, which encourages the realization of fusion fast ignition by laser-driven ions.

  10. Temporal, Diagnostic, and Tissue-Specific Regulation of NRG3 Isoform Expression in Human Brain Development and Affective Disorders.

    PubMed

    Paterson, Clare; Wang, Yanhong; Hyde, Thomas M; Weinberger, Daniel R; Kleinman, Joel E; Law, Amanda J

    2017-03-01

    Genes implicated in schizophrenia are enriched in networks differentially regulated during human CNS development. Neuregulin 3 (NRG3), a brain-enriched neurotrophin, undergoes alternative splicing and is implicated in several neurological disorders with developmental origins. Isoform-specific increases in NRG3 are observed in schizophrenia and associated with rs10748842, a NRG3 risk polymorphism, suggesting NRG3 transcriptional dysregulation as a molecular mechanism of risk. The authors quantitatively mapped the temporal trajectories of NRG3 isoforms (classes I-IV) in the neocortex throughout the human lifespan, examined whether tissue-specific regulation of NRG3 occurs in humans, and determined if abnormalities in NRG3 transcriptomics occur in mood disorders and are genetically determined. NRG3 isoform classes I-IV were quantified using quantitative real-time polymerase chain reaction in human postmortem dorsolateral prefrontal cortex from 286 nonpsychiatric control individuals, from gestational week 14 to 85 years old, and individuals diagnosed with either bipolar disorder (N=34) or major depressive disorder (N=69). Tissue-specific mapping was investigated in several human tissues. rs10748842 was genotyped in individuals with mood disorders, and association with NRG3 isoform expression examined. NRG3 classes displayed individually specific expression trajectories across human neocortical development and aging; classes I, II, and IV were significantly associated with developmental stage. NRG3 class I was increased in bipolar and major depressive disorder, consistent with observations in schizophrenia. NRG3 class II was increased in bipolar disorder, and class III was increased in major depression. The rs10748842 risk genotype predicted elevated class II and III expression, consistent with previous reports in the brain, with tissue-specific analyses suggesting that classes II and III are brain-specific isoforms of NRG3. Mapping the temporal expression of genes during human brain development provides vital insight into gene function and identifies critical sensitive periods whereby genetic factors may influence risk for psychiatric disease. Here the authors provide comprehensive insight into the transcriptional landscape of the psychiatric risk gene, NRG3, in human neocortical development and expand on previous findings in schizophrenia to identify increased expression of developmentally and genetically regulated isoforms in the brain of patients with mood disorders. Principally, the finding that NRG3 classes II and III are brain-specific isoforms predicted by rs10748842 risk genotype and are increased in mood disorders further implicates a molecular mechanism of psychiatric risk at the NRG3 locus and identifies a potential developmental role for NRG3 in bipolar disorder and major depression. These observations encourage investigation of the neurobiology of NRG3 isoforms and highlight inhibition of NRG3 signaling as a potential target for psychiatric treatment development.

  11. Temporal, Diagnostic, and Tissue-Specific Regulation of NRG3 Isoform Expression in Human Brain Development and Affective Disorders

    PubMed Central

    Paterson, Clare; Wang, Yanhong; Hyde, Thomas M.; Weinberger, Daniel R.; Kleinman, Joel E.; Law, Amanda J.

    2018-01-01

    Objective Genes implicated in schizophrenia are enriched in networks differentially regulated during human CNS development. Neuregulin 3 (NRG3), a brain-enriched neurotrophin, undergoes alternative splicing and is implicated in several neurological disorders with developmental origins. Isoform-specific increases in NRG3 are observed in schizophrenia and associated with rs10748842, a NRG3 risk polymorphism, suggesting NRG3 transcriptional dysregulation as a molecular mechanism of risk. The authors quantitatively mapped the temporal trajectories of NRG3 isoforms (classes I–IV) in the neocortex throughout the human lifespan, examined whether tissue-specific regulation of NRG3 occurs in humans, and determined if abnormalities in NRG3 transcriptomics occur in mood disorders and are genetically determined. Method NRG3 isoform classes I–IV were quantified using quantitative real-time polymerase chain reaction in human postmortem dorsolateral prefrontal cortex from 286 nonpsychiatric control individuals, from gestational week 14 to 85 years old, and individuals diagnosed with either bipolar disorder (N=34) or major depressive disorder (N=69). Tissue-specific mapping was investigated in several human tissues. rs10748842 was genotyped in individuals with mood disorders, and association with NRG3 isoform expression examined. Results NRG3 classes displayed individually specific expression trajectories across human neocortical development and aging; classes I, II, and IV were significantly associated with developmental stage. NRG3 class I was increased in bipolar and major depressive disorder, consistent with observations in schizophrenia. NRG3 class II was increased in bipolar disorder, and class III was increased in major depression. The rs10748842 risk genotype predicted elevated class II and III expression, consistent with previous reports in the brain, with tissue-specific analyses suggesting that classes II and III are brain-specific isoforms of NRG3. Conclusions Mapping the temporal expression of genes during human brain development provides vital insight into gene function and identifies critical sensitive periods whereby genetic factors may influence risk for psychiatric disease. Here the authors provide comprehensive insight into the transcriptional landscape of the psychiatric risk gene, NRG3, in human neocortical development and expand on previous findings in schizophrenia to identify increased expression of developmentally and genetically regulated isoforms in the brain of patients with mood disorders. Principally, the finding that NRG3 classes II and III are brain-specific isoforms predicted by rs10748842 risk genotype and are increased in mood disorders further implicates a molecular mechanism of psychiatric risk at the NRG3 locus and identifies a potential developmental role for NRG3 in bipolar disorder and major depression. These observations encourage investigation of the neurobiology of NRG3 isoforms and highlight inhibition of NRG3 signaling as a potential target for psychiatric treatment development. PMID:27771971

  12. Vacuum birefringence detection in all-optical scenarios

    NASA Astrophysics Data System (ADS)

    Ataman, Stefan

    2018-06-01

    In this paper we propose an all-optical vacuum birefringence experiment and evaluate its feasibility for various scenarios. Many petawatt-class lasers became operational and many more are expected to enter operation in the near future, therefore unprecedented electromagnetic fields (EL˜1014-1015 V/m and intensities IL˜1021-1023W/cm 2 ) will become available for experiments. In our proposal a petawatt-class laser disturbs the quantum vacuum and creates a delay in a counterpropagating probe laser beam. Placing this delayed beam in one arm of a Mach-Zehnder interferometer (MZI), allows the measurement of the vacuum refraction coefficient via a phase shift. Coherent as well as squeezed light are both considered and the minimum phase sensitivity evaluated. We show that using existing technology with some moderately optimistic assumptions, at least part of the discussed scenarios are feasible for a vacuum birefringence detection experiment.

  13. Wave kinetics of random fibre lasers

    PubMed Central

    Churkin, D V.; Kolokolov, I V.; Podivilov, E V.; Vatnik, I D.; Nikulin, M A.; Vergeles, S S.; Terekhov, I S.; Lebedev, V V.; Falkovich, G.; Babin, S A.; Turitsyn, S K.

    2015-01-01

    Traditional wave kinetics describes the slow evolution of systems with many degrees of freedom to equilibrium via numerous weak non-linear interactions and fails for very important class of dissipative (active) optical systems with cyclic gain and losses, such as lasers with non-linear intracavity dynamics. Here we introduce a conceptually new class of cyclic wave systems, characterized by non-uniform double-scale dynamics with strong periodic changes of the energy spectrum and slow evolution from cycle to cycle to a statistically steady state. Taking a practically important example—random fibre laser—we show that a model describing such a system is close to integrable non-linear Schrödinger equation and needs a new formalism of wave kinetics, developed here. We derive a non-linear kinetic theory of the laser spectrum, generalizing the seminal linear model of Schawlow and Townes. Experimental results agree with our theory. The work has implications for describing kinetics of cyclical systems beyond photonics. PMID:25645177

  14. Nasal potential difference in cystic fibrosis considering severe CFTR mutations.

    PubMed

    Ng, Ronny Tah Yen; Marson, Fernando Augusto de Lima; Ribeiro, Jose Dirceu; Ribeiro, Antonio Fernando; Bertuzzo, Carmen Silvia; Ribeiro, Maria Angela Gonçalves de Oliveira; Severino, Silvana Dalge; Sakano, Eulalia

    2015-01-01

    The gold standard for diagnosing cystic fibrosis (CF) is a sweat chloride value above 60 mEq/L. However, this historical and important tool has limitations; other techniques should be studied, including the nasal potential difference (NPD) test. CFTR gene sequencing can identify CFTR mutations, but this method is time-consuming and too expensive to be used in all CF centers. The present study compared CF patients with two classes I-III CFTR mutations (10 patients) (G1), CF patients with classes IV-VI CFTR mutations (five patients) (G2), and 21 healthy subjects (G3). The CF patients and healthy subjects also underwent the NPD test. A statistical analysis was performed using the Mann-Whitney, Kruskal-Wallis, χ(2), and Fisher's exact tests, α = 0.05. No differences were observed between the CF patients and healthy controls for the PDMax, Δamiloride, and Δchloride + free + amiloride markers from the NPD test. For the finger value, a difference between G2 and G3 was described. The Wilschanski index values were different between G1 and G3. In conclusion, our data showed that NPD is useful for CF diagnosis when classes I-III CFTR mutations are screened. However, if classes IV-VI are considered, the NPD test showed an overlap in values with healthy subjects.

  15. Nasal Potential Difference in Cystic Fibrosis considering Severe CFTR Mutations

    PubMed Central

    Ng, Ronny Tah Yen; Marson, Fernando Augusto de Lima; Ribeiro, Jose Dirceu; Ribeiro, Antonio Fernando; Bertuzzo, Carmen Silvia; Ribeiro, Maria Angela Gonçalves de Oliveira; Severino, Silvana Dalge; Sakano, Eulalia

    2015-01-01

    The gold standard for diagnosing cystic fibrosis (CF) is a sweat chloride value above 60 mEq/L. However, this historical and important tool has limitations; other techniques should be studied, including the nasal potential difference (NPD) test. CFTR gene sequencing can identify CFTR mutations, but this method is time-consuming and too expensive to be used in all CF centers. The present study compared CF patients with two classes I-III CFTR mutations (10 patients) (G1), CF patients with classes IV-VI CFTR mutations (five patients) (G2), and 21 healthy subjects (G3). The CF patients and healthy subjects also underwent the NPD test. A statistical analysis was performed using the Mann-Whitney, Kruskal-Wallis, χ 2, and Fisher's exact tests, α = 0.05. No differences were observed between the CF patients and healthy controls for the PDMax, Δamiloride, and Δchloride + free + amiloride markers from the NPD test. For the finger value, a difference between G2 and G3 was described. The Wilschanski index values were different between G1 and G3. In conclusion, our data showed that NPD is useful for CF diagnosis when classes I-III CFTR mutations are screened. However, if classes IV-VI are considered, the NPD test showed an overlap in values with healthy subjects. PMID:25667564

  16. COPD predicts mortality in HF: the Norwegian Heart Failure Registry.

    PubMed

    De Blois, Jonathan; Simard, Serge; Atar, Dan; Agewall, Stefan

    2010-03-01

    Chronic obstructive pulmonary disease (COPD) and chronic heart failure (HF) are common clinical conditions that share tobacco as a risk factor. Our aim was to evaluate the prognostic impact of COPD on HF patients. The Norwegian Heart Failure Registry was used. The study included 4132 HF patients (COPD, n = 699) from 22 hospitals (mean follow-up, 13.3 months). COPD patients were older, more often smokers and diabetics, less often on beta-blockers and had a higher heart rate. They were more often in New York Heart Association (NYHA) Class III or IV (COPD, 63%; no COPD, 51%), although left ventricular ejection fraction (LVEF) distribution was similar. COPD independently predicted death (adjusted hazard ratio [HR], 1.188; 95% CI: 1.015 to 1.391; P = 0.03) along with age, creatinine, NYHA Class III/IV (HR, 1.464; 95% CI: 1.286 to 1.667) and diabetes. beta-blockers at baseline were associated with improved survival in patients with LVEF < or =40% independently of COPD. COPD is associated with a poorer survival in HF patients. COPD patients are overrated in terms of NYHA class in comparison with patients with similar LVEF. Nonetheless, NYHA class remains the strongest predictor of death in these patients. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  17. Response of dosemeters in the radiation field generated by a TW-class laser system.

    PubMed

    Olšovcová, V; Klír, D; Krása, J; Krůs, M; Velyhan, A; Zelenka, Z; Rus, B

    2014-10-01

    State-of-the-art laser systems are able to generate ionising radiation of significantly high energies by focusing ultra-short and intense pulses onto targets. Thus, measures ensuring the radiation protection of both working personnel and the general public are required. However, commercially available dosemeters are primarily designed for measurement in continuous fields. Therefore, it is important to explore their response to very short pulses. In this study, the responses of dosemeters in a radiation field generated by iodine high-power and Ti:Sapphire laser systems are examined in proton and electron acceleration experiments. Within these experiments, electron bunches of femtosecond pulse duration and 100-MeV energy and proton bunches with sub-nanosecond pulse duration and energy of several megaelectronvolts were generated in single-shot regimes. Responses of typical detectors (TLD, films and electronic personal dosemeter) were analysed and compared. Further, a first attempt was carried out to characterise the radiation field generated by TW-class laser systems. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Measuring the temperature history of isochorically heated warm dense metals

    NASA Astrophysics Data System (ADS)

    McGuffey, Chris; Kim, J.; Park, J.; Moody, J.; Emig, J.; Heeter, B.; Dozieres, M.; Beg, Fn; McLean, Hs

    2017-10-01

    A pump-probe platform has been designed for soft X-ray absorption spectroscopy near edge structure measurements in isochorically heated Al or Cu samples with temperature of 10s to 100s of eV. The method is compatible with dual picosecond-class laser systems and may be used to measure the temperature of the sample heated directly by the pump laser or by a laser-driven proton beam Knowledge of the temperature history of warm dense samples will aid equation of state measurements. First, various low- to mid-Z targets were evaluated for their suitability as continuum X-ray backlighters over the range 200-1800 eV using a 10 J picosecond-class laser with relativistic peak intensity Alloys were found to be more suitable than single-element backlighters. Second, the heated sample package was designed with consideration of target thickness and tamp layers using atomic physics codes. The results of the first demonstration attempts will be presented. This work was supported by the U.S. DOE under Contract No. DE-SC0014600.

  19. Characteristics of a High Intensity, Pulsed, Potassium Vapor Laser in a Heat Pipe

    DTIC Science & Technology

    2011-03-01

    USAF AFIT/GE/ENG/11-17 DEPARTMENT OF THE AIR FORCE AIR UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base , Ohio...the chemical oxygen iodine laser (COIL). While it is effective, it also has drawbacks. The COIL requires a Boeing 747 to house the laser, the...amount of chemical stored onboard the aircraft [1]. There are a number of ongoing research projects to develop the next generation megawatt class

  20. Ultrashort laser pulse driven inverse free electron laser accelerator experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moody, J. T.; Anderson, S. G.; Anderson, G.

    In this paper we discuss the ultrashort pulse high gradient Inverse Free Electron laser accelerator experiment carried out at the Lawrence Livermore National Laboratory which demonstrated gra- dients exceeding 200 MV/m using a 4 TW 100 fs long 800 nm Ti:Sa laser pulse. Due to the short laser and electron pulse lengths, synchronization was determined to be one of the main challenges in this experiment. This made necessary the implementation of a single-shot, non destructive, electro-optic sampling based diagnostics to enable time-stamping of each laser accelerator shot with < 100 fs accuracy. The results of this experiment are expected tomore » pave the way towards the development of future GeV-class IFEL accelerators.« less

  1. Measurement of the target current by inductive probe during laser interaction on terawatt laser system PALS.

    PubMed

    Cikhardt, J; Krása, J; De Marco, M; Pfeifer, M; Velyhan, A; Krouský, E; Cikhardtová, B; Klír, D; Rezáč, K; Ullschmied, J; Skála, J; Kubeš, P; Kravárik, J

    2014-10-01

    Measurements of the return-current flowing through a solid target irradiated with the sub-nanosecond kJ-class Prague Asterix Laser System is reported. A new inductive target probe was developed which allows us measuring the target current derivative in a kA/ns range. The dependences of the target current on the laser pulse energy for cooper, graphite, and polyethylene targets are reported. The experiment shows that the target current is proportional to the deposited laser energy and is strongly affected by the shot-to-shot fluctuations. The corresponding maximum target charge exceeded a value of 10 μC. A return-current dependence of the electromagnetic pulse produced by the laser-target interaction is presented.

  2. Ultrashort laser pulse driven inverse free electron laser accelerator experiment

    DOE PAGES

    Moody, J. T.; Anderson, S. G.; Anderson, G.; ...

    2016-02-29

    In this paper we discuss the ultrashort pulse high gradient Inverse Free Electron laser accelerator experiment carried out at the Lawrence Livermore National Laboratory which demonstrated gra- dients exceeding 200 MV/m using a 4 TW 100 fs long 800 nm Ti:Sa laser pulse. Due to the short laser and electron pulse lengths, synchronization was determined to be one of the main challenges in this experiment. This made necessary the implementation of a single-shot, non destructive, electro-optic sampling based diagnostics to enable time-stamping of each laser accelerator shot with < 100 fs accuracy. The results of this experiment are expected tomore » pave the way towards the development of future GeV-class IFEL accelerators.« less

  3. Novel Approach to Treating Androgenetic Alopecia in Females With Photobiomodulation (Low-Level Laser Therapy).

    PubMed

    Friedman, Shelly; Schnoor, Patricia

    2017-06-01

    Photobiomodulation, also referred to as low-level laser therapy (LLLT), has been studied and used for (among other diseases) the promotion of hair regrowth. A clinical study was developed to define the physiologic effects that occur when the human hair follicle and surrounding tissue structures are exposed to laser light using a novel device that is fitted with an array of laser diode sources operating at 650 nm and placed inside a sports cap to promote discretion while in use. The study demonstrates that low-level laser treatment of the scalp every other day for 17 weeks using the HANDI-DOME LASER device is a safe and effective treatment for androgenetic alopecia in healthy females between the ages of 18 to 60 with Fitzpatrick skin Types I to IV and Ludwig-Savin Baldness Scale I-2 to II-2 baldness patterns. Subjects receiving LLLT at 650 nm achieved a 51% increase in hair counts as compared with sham-treated control patients in this multicenter randomized controlled trial. These results suggest that the emerging technology of low-level laser therapy may play a potentially significant role in health care providers' armamentarium for the disease androgenic alopecia.

  4. Control of Flagellar Gene Regulation in Legionella pneumophila and Its Relation to Growth Phase▿ †

    PubMed Central

    Albert-Weissenberger, Christiane; Sahr, Tobias; Sismeiro, Odile; Hacker, Jörg; Heuner, Klaus; Buchrieser, Carmen

    2010-01-01

    The bacterial pathogen Legionella pneumophila responds to environmental changes by differentiation. At least two forms are well described: replicative bacteria are avirulent; in contrast, transmissive bacteria express virulence traits and flagella. Phenotypic analysis, Western blotting, and electron microscopy of mutants of the regulatory genes encoding RpoN, FleQ, FleR, and FliA demonstrated that flagellin expression is strongly repressed and that the mutants are nonflagellated in the transmissive phase. Transcriptome analyses elucidated that RpoN, together with FleQ, enhances transcription of 14 out of 31 flagellar class II genes, which code for the basal body, hook, and regulatory proteins. Unexpectedly, FleQ independent of RpoN enhances the transcription of fliA encoding sigma 28. Expression analysis of a fliA mutant showed that FliA activates three out of the five remaining flagellar class III genes and the flagellar class IV genes. Surprisingly, FleR does not induce but inhibits expression of at least 14 flagellar class III genes on the transcriptional level. Thus, we propose that flagellar class II genes are controlled by FleQ and RpoN, whereas the transcription of the class III gene fliA is controlled in a FleQ-dependent but RpoN-independent manner. However, RpoN and FleR might influence flagellin synthesis on a posttranscriptional level. In contrast to the commonly accepted view that enhancer-binding proteins such as FleQ always interact with RpoN to fullfill their regulatory functions, our results strongly indicate that FleQ regulates gene expression that is RpoN dependent and RpoN independent. Finally, FliA induces expression of flagellar class III and IV genes leading to the complete synthesis of the flagellum. PMID:19915024

  5. Long-Term Electroclinical and Employment Follow up in Temporal Lobe Epilepsy Surgery. A Cuban Comprehensive Epilepsy Surgery Program

    PubMed Central

    Garcia Maeso, Ivan; Baez Martin, Margarita M.; Bender del Busto, Juan E.; García Navarro, María Eugenia; Quintanal Cordero, Nelson; Estupiñan Díaz, Bárbara; Lorigados Pedre, Lourdes; Valdés Yerena, Ricardo; Gonzalez, Judith; Garbey Fernandez, Randy; Sánchez Coroneux, Abel

    2018-01-01

    The purpose of this paper is to present a long- term electroclinical and employment follow up in temporal lobe epilepsy (TLE) patients in a comprehensive epilepsy surgery program. Forty adult patients with pharmacoresistant TLE underwent detailed presurgical evaluation. Electroencephalogram (EEG) and clinical follow up assessment for each patient were carried out. The occurrence of interictal epileptiform activity (IEA) and absolute spike frequency (ASF) were tabulated before and after 1, 6, 12, 24 and 72 months surgical treatment. Employment status pre- to post-surgery at the last evaluated period was also examined. Engel scores follow-up was described as follows: at 12 months 70% (28) class I, 10% (4) class II and 19% (8) class III-IV; at 24 months after surgery 55.2% (21) of the patients were class I, 28.9% (11) class II and 15.1% (6) class III-IV. After one- year follow up 23 (57.7%) patients were seizure and aura-free (Engel class IA). These figures changed to 47.3%, and 48.6% respectively two and five years following surgery whereas 50% maintained this condition in the last follow up period. A decline in the ASF was observed from the first year until the sixth year after surgery in relation to the preoperative EEG. The ASF one year after surgery allowed to distinguish “satisfactory” from “unsatisfactory” seizure relief outcome at the last follow up. An adequate social functioning in terms of education and employment in more than 50% of the patients was also found. Results revealed the feasibility of conducting a successful epilepsy surgery program with favorable long term electroclinical and psychosocial functioning outcomes in a developing country as well. PMID:29389846

  6. The Long Range Reconnaissance and Observation System (LORROS) with the Kollsman, Inc. Model LH-40, Infrared (Erbium) Laser Rangefinder hazard analysis and safety assessment.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Augustoni, Arnold L.

    A laser hazard analysis and safety assessment was performed for the LH-40 IR Laser Rangefinder based on the 2000 version of the American National Standard Institute's Standard Z136.1, for the Safe Use of Lasers and Z136.6, for the Safe Use of Lasers Outdoors. The LH-40 IR Laser is central to the Long Range Reconnaissance and Observation System (LORROS). The LORROS is being evaluated by the Department 4149 Group to determine its capability as a long-range assessment tool. The manufacture lists the laser rangefinder as 'eye safe' (Class 1 laser classified under the CDRH Compliance Guide for Laser Products and 21more » CFR 1040 Laser Product Performance Standard). It was necessary that SNL validate this prior to its use involving the general public. A formal laser hazard analysis is presented for the typical mode of operation.« less

  7. The intravascular low level laser irradiation (ILLLI) in treatment of psoriasis clinically

    NASA Astrophysics Data System (ADS)

    Zhu, Jing; Nie, Fan; Shi, Hong-Min

    2005-07-01

    Objective: The title is research curative effect of intravascular low level laser irradiation (ILLLI) in treatment of psoriasis. Method: 478 patients with psoriasis from five groups to observe their efficacy. Group1 were treated by He-Ne laser combined with drug. Group 2 were treated by semi-conductor laser combined with drug. Group 3 were treated only by He-He laser. Group 4 were treated by semi-conductor laser. Group 5 were treated only by drug. The Ridit statistical analysis was applied to all of these data. The treatment of intravascular low level laser irradiation is as follow: laser power:4-5mw, 1 hour per day and 10 days as a period combined with vit C 2.0 g iv and inhalation of O2. Results: The clinical results: the near efficient rate was 100%, in group1-4, if combined with drugs it would be better. Ridit statistical analysis showed no significant difference between group1-4, p>0.05. The efficient rate 72.97% in group5.There were showed very significant difference with group1-4, p<0.01. 2.There were no significant differences between He-Ne laser (632.8nm) and semiconductor laser(650nm); 3.The efficacy of ILLLI in psoriasis was positive correlation to the ILLLI times. Conclusions: It can improve curative effect of intravascular low levellaser irradiation (ILLLI) in treatment of psoriasis.

  8. Combined risk assessment of nonstationary monthly water quality based on Markov chain and time-varying copula.

    PubMed

    Shi, Wei; Xia, Jun

    2017-02-01

    Water quality risk management is a global hot research linkage with the sustainable water resource development. Ammonium nitrogen (NH 3 -N) and permanganate index (COD Mn ) as the focus indicators in Huai River Basin, are selected to reveal their joint transition laws based on Markov theory. The time-varying moments model with either time or land cover index as explanatory variables is applied to build the time-varying marginal distributions of water quality time series. Time-varying copula model, which takes the non-stationarity in the marginal distribution and/or the time variation in dependence structure between water quality series into consideration, is constructed to describe a bivariate frequency analysis for NH 3 -N and COD Mn series at the same monitoring gauge. The larger first-order Markov joint transition probability indicates water quality state Class V w , Class IV and Class III will occur easily in the water body of Bengbu Sluice. Both marginal distribution and copula models are nonstationary, and the explanatory variable time yields better performance than land cover index in describing the non-stationarities in the marginal distributions. In modelling the dependence structure changes, time-varying copula has a better fitting performance than the copula with the constant or the time-trend dependence parameter. The largest synchronous encounter risk probability of NH 3 -N and COD Mn simultaneously reaching Class V is 50.61%, while the asynchronous encounter risk probability is largest when NH 3 -N and COD Mn is inferior to class V and class IV water quality standards, respectively.

  9. Erosion assessment at the Petroglyph National Monument area, Albuquerque, New Mexico

    USGS Publications Warehouse

    Gellis, A.C.

    1995-01-01

    Areas of the Petroglyph National Monument, specifically those located along the West Mesa escarpment, are being affected by erosion and gullying. A reconnaissance along the 17-mile-long escarpment identified 50 gullies. The gullies were given a qualitative ranking of Class I, least erosion, to Class IV, highest erosion. Of the 50 gullies identified, 21 were assigned Class I, 22 to Class II, 6 to Class III, and 1 to Class IV. Although the gullies may not be a direct threat to petroglyphs, the effects of gullying may have a greater effect on the aesthetics of the monument and the residences located downgradient from a gully. Most of the gullies were found along the northern part of the escarpment. This area, which is more developed than the southern areas of the escarpment, contains many dirt roads and nonpaved foot and bicycle paths. These features channel surface runoff and increase erosion. Thirty of the 50 gullies were noted as being connected to the runoff from dirt roads. High-intensity storms during the summer of 1991 may have caused or increased gullying. Analyses of these storms indicate recurrence intervals of rainfall of no more than 2 years. Indirect measurements of peak discharge in La Boca Negra Arroyo after the August 22, 1991, storm indicate that this runoff event may have a frequency of no more than 10 years. Regional frequency reports on rainfall and data collected at the rain gages indicate that gullying and erosion that occurred during the summer of 1991 were not a result of infrequent rainfall or runoff events.

  10. HairMax LaserComb laser phototherapy device in the treatment of male androgenetic alopecia: A randomized, double-blind, sham device-controlled, multicentre trial.

    PubMed

    Leavitt, Matt; Charles, Glenn; Heyman, Eugene; Michaels, David

    2009-01-01

    The use of low levels of visible or near infrared light for reducing pain, inflammation and oedema, promoting healing of wounds, deeper tissue and nerves, and preventing tissue damage has been known for almost 40 years since the invention of lasers. The HairMax LaserComb is a hand-held Class 3R lower level laser therapy device that contains a single laser module that emulates 9 beams at a wavelength of 655 nm (+/-5%). The device uses a technique of parting the user's hair by combs that are attached to the device. This improves delivery of distributed laser light to the scalp. The combs are designed so that each of the teeth on the combs aligns with a laser beam. By aligning the teeth with the laser beams, the hair can be parted and the laser energy delivered to the scalp of the user without obstruction by the individual hairs on the scalp. The primary aim of the study was to assess the safety and effectiveness of the HairMax LaserComb laser phototherapy device in the promotion of hair growth and in the cessation of hair loss in males diagnosed with androgenetic alopecia (AGA). This double-blind, sham device-controlled, multicentre, 26-week trial randomized male patients with Norwood-Hamilton classes IIa-V AGA to treatment with the HairMax LaserComb or the sham device (2 : 1). The sham device used in the study was identical to the active device except that the laser light was replaced by a non-active incandescent light source. Of the 110 patients who completed the study, subjects in the HairMax LaserComb treatment group exhibited a significantly greater increase in mean terminal hair density than subjects in the sham device group (p < 0.0001). Consistent with this evidence for primary effectiveness, significant improvements in overall hair regrowth were demonstrated in terms of patients' subjective assessment (p < 0.015) at 26 weeks over baseline. The HairMax LaserComb was well tolerated with no serious adverse events reported and no statistical difference in adverse effects between the study groups. The results of this study suggest that the HairMax LaserComb is an effective, well tolerated and safe laser phototherapy device for the treatment of AGA in males.

  11. New advanced characterization tools for PW-class lasers (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Quéré, Fabien

    2017-05-01

    Spatio-temporal couplings (STC) of laser beams are ubiquitous in ultrafast optics. In the femtosecond range, chirped-pulse amplification (CPA), the key technology of amplified ultrashort pulses, relies on the use of massive STCs induced at different locations in laser systems (for instance by gratings or prisms), which should all eventually perfectly cancel out at the laser output. Residual STCs, for example resulting from imperfect compensation, decrease the peak intensity at focus by increasing both the focal spot size and the pulse duration. This is particularly detrimental for ultrahigh-intensity (UHI) lasers, which aim for the highest possible peak intensities. However, it is precisely with these lasers that such uncontrolled defects are most likely to occur, due to the complexity of these systems and the large diameters of the output beams. Accurately measuring STCs is thus essential in ultrafast optics. Significant progress has been made in the last decade, and several techniques are now available for the partial or complete spatiotemporal characterization of near-visible femtosecond laser beams. However, none of these has yet been applied to UHI femtosecond lasers, due to the difficulty of handling these large and powerful beams. As a result, all UHI lasers are currently characterized under the unjustified and unverified assumption of the absence of STCs, using separate measurements in space and time. This situation is now becoming a major bottleneck for the development of UHI lasers and their applications. In particular, the optimal and reliable operation of PW-class lasers now available or under construction all around the world will simply not be possible without a proper spatiotemporal metrology. In this talk, we present the first complete spatiotemporal experimental reconstruction of the field E(t,r) for a 100 TW peak-power laser, obtained using self-referenced spatially-resolved Fourier transform spectroscopy [1,2], and thus reveal the spatiotemporal distortions that can affect such beams [3]. This new measurement capability opens the way to in-depth characterization and optimization of ultra-intense lasers and ultimately to the advanced control of relativistic motion of matter with femtosecond laser beams structured in space-time.

  12. New application of the long-pulsed Nd-YAG laser as an ablative resurfacing tool for skin rejuvenation: a 7-year study.

    PubMed

    Alshami, Mohammad Ali

    2013-09-01

    Carbon dioxide (CO2 ) and erbium-yttrium aluminum garnet (Er-YAG) lasers are the gold standards in ablative skin resurfacing. Neodymium-doped yttrium aluminum garnet (Nd-YAG) laser is considered a nonablative skin resurfacing laser whose usage is limited due to its high cost. To assess the efficacy and safety of Nd-YAG as an ablative resurfacing laser and to compare the results with those previously published for CO2 and Erbium-YAG lasers. A total of 296 patients (251 female and 45 male) with Fitzpatrick skin types III-IV and dermatological conditions amenable to ablative skin resurfacing participated in this study. Nd-YAG laser parameters assessed were wavelength (1064 nm), pulse duration (5 ms), fluence (10 J/cm(2) ), and spot size (8-10 mm). Efficacy of Nd-YAG laser was assessed by comparing pre- and posttreatment photographs. An improvement of 30-80% was observed in treated patients. The degree of improvement correlated positively with the number of laser sessions. The most common side effect was hyperpigmentation. Other side effects were less common and mild in intensity compared with published results for gold standard ablative lasers. Not only was the Nd-YAG laser found to be as effective as Er-YAG and CO2 lasers, but treated patients also had shorter recovery and treatment times, and at lower cost. © 2013 Wiley Periodicals, Inc.

  13. I-V Characteristics vs. Spatial Dissipation Maps in YBCO Grain Boundary on Bicrystal Substrates

    NASA Astrophysics Data System (ADS)

    Kwon, Chuhee; Yamamoto, Megumi; Pottish, Samuel; Haugan, Timothy; Barnes, Paul

    2008-03-01

    Grain boundary (GB) properties of YBCO films on SrTiO3 bicrystal substrates with 24 degree misorientations are examined by transport and scanning laser microscopy (SLM) techniques. Thermoelectric SLM clearly shows the location of grain boundaries, and variable temperature SLM confirms that GB has lower Tc. A series of I-V measured in superconducting states exhibit clear step-like features identified in earlier papers as sub-gap structures. The low temperature SLM shows a close relation between the step-like features and the local dissipation pattern in GB. We believe that the activation of Fiske steps is responsible for the step-like I-V, and SLM images show the spatial pattern of the self-excited resonance in GB. We will also discuss how Ca-doping and nanoparticle additions on YBCO affect the junction properties.

  14. 7 CFR 900.4 - Institution of proceeding.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... involved and shall state the industry, area, and class of persons to be regulated, the time and place of... reasonably will tend to bring the ntoice to the attention of the persons interested therein; (iv) By...

  15. Permanent data recording in transparent materials by using a nanojoule-class pulse laser

    NASA Astrophysics Data System (ADS)

    Imai, Ryo; Shiozawa, Manabu; Watanabe, Takao; Umeda, Mariko; Mine, Toshiyuki; Kuretake, Satoshi; Watanabe, Koichi

    2014-09-01

    We investigated data recording for permanent data storage using an ultrafast pulse laser with nanojoule-class pulse energy and megahertz-class repetition rate in transparent materials, and driveless reading based on a simple imaging system. A transparent ceramics called Lumicera®, manufactured by Murata Mfg. Co., Ltd., was used as the recording medium. Lumicera® has a lower modification threshold and a higher recording sensitivity than those of silica glass, namely, the medium previously studied. Structural modification in Lumicera® occurs by light exposure for 10 μs, suggesting that Lumicera® has potential for a recording speed of over 100 kbps. Data recorded in Lumicera® resists heating for 2 h at 1000 °C and is expected to have a lifetime of over 300 million years. Moreover, the data recorded in Lumicera® was successfully read with a reading system based on a smart phone.

  16. Low-intensity red and infrared laser effects at high fluences on Escherichia coli cultures

    PubMed Central

    Barboza, L.L.; Campos, V.M.A.; Magalhães, L.A.G.; Paoli, F.; Fonseca, A.S.

    2015-01-01

    Semiconductor laser devices are readily available and practical radiation sources providing wavelength tenability and high monochromaticity. Low-intensity red and near-infrared lasers are considered safe for use in clinical applications. However, adverse effects can occur via free radical generation, and the biological effects of these lasers from unusually high fluences or high doses have not yet been evaluated. Here, we evaluated the survival, filamentation induction and morphology of Escherichia coli cells deficient in repair of oxidative DNA lesions when exposed to low-intensity red and infrared lasers at unusually high fluences. Cultures of wild-type (AB1157), endonuclease III-deficient (JW1625-1), and endonuclease IV-deficient (JW2146-1) E. coli, in exponential and stationary growth phases, were exposed to red and infrared lasers (0, 250, 500, and 1000 J/cm2) to evaluate their survival rates, filamentation phenotype induction and cell morphologies. The results showed that low-intensity red and infrared lasers at high fluences are lethal, induce a filamentation phenotype, and alter the morphology of the E. coli cells. Low-intensity red and infrared lasers have potential to induce adverse effects on cells, whether used at unusually high fluences, or at high doses. Hence, there is a need to reinforce the importance of accurate dosimetry in therapeutic protocols. PMID:26445339

  17. Laser Tattoo Removal: An Update.

    PubMed

    Naga, Lina I; Alster, Tina S

    2017-02-01

    Tattoo art has been around for thousands of years in every culture and is currently flourishing in all age groups, social classes, and occupations. Despite the rising popularity of tattoos, demand for their removal has also increased. While various treatments, including surgical excision, dermabrasion, and chemical destruction have historically been applied, over the past 2 decades, lasers have revolutionized the way tattoos are treated and have become the gold standard of treatment. To achieve optimal cosmetic outcome of treatment, lasers emitting high energies and short pulses are required to adequately destroy tattoo ink. We review the history of laser tattoo removal, outlining the challenges inherent in developing lasers that can most effectively remove tattoo particles while safely protecting skin from unwanted injury.

  18. Assessment of bone healing on tibial fractures treated with wire osteosynthesis associated or not with infrared laser light and biphasic ceramic bone graft (HATCP) and guided bone regeneration (GBR): Raman spectroscopy study

    NASA Astrophysics Data System (ADS)

    Bastos de Carvalho, Fabíola; Aciole, Gilberth Tadeu S.; Aciole, Jouber Mateus S.; Silveira, Landulfo, Jr.; Nunes dos Santos, Jean; Pinheiro, Antônio L. B.

    2011-03-01

    The aim of this study was to evaluate, through Raman spectroscopy, the repair of complete tibial fracture in rabbits fixed with wire osteosynthesis - WO, treated or not with infrared laser light (λ 780nm, 50mW, CW) associated or not to the use of HATCP and GBR. Surgical fractures were created under general anesthesia (Ketamine 0.4ml/Kg IP and Xilazine 0.2ml/Kg IP), on the tibia of 15 rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with WO. Animals of groups III and V were grafted with hydroxyapatite + GBR technique. Animals of groups IV and V were irradiated at every other day during two weeks (16J/cm2, 4 x 4J/cm2). Observation time was that of 30 days. After animal death the specimens were kept in liquid nitrogen for further analysis by Raman spectroscopy. Raman spectroscopy showed significant differences between groups (p<0.001). It is concluded that IR laser light was able to accelerate fracture healing and the association with HATCP and GBR resulted on increased deposition of calcium hydroxyapatite.

  19. Mid-infrared lasers for energy frontier plasma accelerators

    DOE PAGES

    Pogorelsky, I. V.; Polyanskiy, M. N.; Kimura, W. D.

    2016-09-12

    Plasma wake field accelerators driven with solid-state near-IR lasers have been considered as an alternative to conventional rf accelerators for next-generation TeV-class lepton colliders. Here, we extend this study to the mid-IR spectral domain covered by CO 2 lasers. We conclude that the increase in the laser driver wavelength favors the regime of laser wake field acceleration with a low plasma density and high electric charge. This regime is the most beneficial for gamma colliders to be converted from lepton colliders via inverse Compton scattering. Selecting a laser wavelength to drive a Compton gamma source is essential for the designmore » of such a machine. In conclusion, the revealed benefits from spectral diversification of laser drivers for future colliders and off-spring applications validate ongoing efforts in advancing the ultrafast CO 2 laser technology.« less

  20. Correlation of the New York Heart Association Classification and the 6-Minute Walk Distance: A Systematic Review.

    PubMed

    Yap, Jonathan; Lim, Fang Yi; Gao, Fei; Teo, Ling Li; Lam, Carolyn Su Ping; Yeo, Khung Keong

    2015-10-01

    Functional status assessment is the cornerstone of heart failure management and trials. The New York Heart Association (NYHA) classification and 6-minute walk distance (6MWD) are commonly used tools; however, the correlation between them is not well understood. We hypothesised that the relationship between the NYHA classification and 6MWD might vary across studies. A systematic literature search was performed to identify all studies reporting both NYHA class and 6MWD. Two reviewers independently assessed study eligibility and extracted data. Thirty-seven studies involving 5678 patients were included. There was significant heterogeneity across studies in 6MWD within all NYHA classes: I (n = 16, Q = 934.2; P < 0.001), II (n = 25, Q = 1658.3; P < 0.001), III (n = 30, Q = 1020.1; P < 0.001), and IV (n = 6, Q = 335.5; P < 0.001). There was no significant difference in average 6MWD between NYHA I and II (420 m vs 393 m; P = 0.416). There was a significant difference in average 6MWD between NYHA II and III (393 m vs 321 m; P = 0.014) and III and IV (321 m vs 224 m; P = 0.027). This remained significant after adjusting for region of study, age, and sex. Although there is an inverse correlation between NYHA II-IV and 6MWD, there is significant heterogeneity across studies in 6MWD within each NYHA class and overlap in 6MWD between NYHA I and II. The NYHA classification performs well in more symptomatic patients (NYHA III/IV) but less so in asymptomatic/mildly symptomatic patients (NYHA I/II). Nonetheless, the NYHA classification is an easily applied first-line tool in everyday clinical practice, but its potential subjectivity should be considered when performing comparisons across studies. © 2015 Wiley Periodicals, Inc.

  1. A Low-Cost Time-Resolved Spectrometer for the Study of Ruby Emission

    ERIC Educational Resources Information Center

    McBane, George C.; Cannella, Christian; Schaertel, Stephanie

    2018-01-01

    A low-cost time-resolved emission spectrometer optimized for ruby emission is presented. The use of a Class II diode laser module as the excitation source reduces costs and hazards. The design presented here can facilitate the inclusion of time-resolved emission spectroscopy with laser excitation sources in the undergraduate laboratory curriculum.…

  2. Isotope shifts from collinear laser spectroscopy of doubly charged yttrium isotopes

    NASA Astrophysics Data System (ADS)

    Vormawah, L. J.; Vilén, M.; Beerwerth, R.; Campbell, P.; Cheal, B.; Dicker, A.; Eronen, T.; Fritzsche, S.; Geldhof, S.; Jokinen, A.; Kelly, S.; Moore, I. D.; Reponen, M.; Rinta-Antila, S.; Stock, S. O.; Voss, A.

    2018-04-01

    Collinear laser spectroscopy has been performed on doubly charged ions of radioactive yttrium in order to study the isotope shifts of the 294.6-nm 5 s 1/2 2S →5 p 1/2 2P line. The potential of such an alkali-metal-like transition to improve the reliability of atomic-field-shift and mass-shift factor calculations, and hence the extraction of nuclear mean-square radii, is discussed. Production of yttrium ion beams for such studies is available at the IGISOL IV Accelerator Laboratory, Jyväskylä, Finland. This newly recommissioned facility is described here in relation to the on-line study of accelerator-produced short-lived isotopes using collinear laser spectroscopy and application of the technique to doubly charged ions.

  3. Advanced Accelerators for Medical Applications

    NASA Astrophysics Data System (ADS)

    Uesaka, Mitsuru; Koyama, Kazuyoshi

    We review advanced accelerators for medical applications with respect to the following key technologies: (i) higher RF electron linear accelerator (hereafter "linac"); (ii) optimization of alignment for the proton linac, cyclotron and synchrotron; (iii) superconducting magnet; (iv) laser technology. Advanced accelerators for medical applications are categorized into two groups. The first group consists of compact medical linacs with high RF, cyclotrons and synchrotrons downsized by optimization of alignment and superconducting magnets. The second group comprises laserbased acceleration systems aimed of medical applications in the future. Laser plasma electron/ion accelerating systems for cancer therapy and laser dielectric accelerating systems for radiation biology are mentioned. Since the second group has important potential for a compact system, the current status of the established energy and intensity and of the required stability are given.

  4. Bibliography of Soviet Laser Developments, Number 58, March-April 1982.

    DTIC Science & Technology

    1983-05-01

    generation and diagnostics . DD IA7 1473 EOITION OF I NOV A OSOLETE UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE (When Does Entered) Introduction...10 C. He-Kr............................................. 10 iv 2. Molecular Beam and lIon a. C02...104 K. Plasma Generation and Diagnostics ....................... 105 III. MONOGRAPHS, BOOKS, CONFERENCE PROCEEDINGS................... 113

  5. National Aerospace Leadership Initiative - Phase 2

    DTIC Science & Technology

    2010-03-01

    components) for turbine airfoils and larger sized components (e.g., combustor, augmenter, and nozzle applications). Substrate material properties ...material property impact to sensing, measurement and breakthrough detection. Establishment of CCAT’s Laser Applications Laboratory that includes next...generation and materials property (and component) validation. Task IV - Total Supply Chain Enterprise Effectiveness The competitiveness and

  6. Optical damage testing at the Z-Backlighter facility at Sandia National Laboratories

    NASA Astrophysics Data System (ADS)

    Kimmel, Mark; Rambo, Patrick; Broyles, Robin; Geissel, Matthias; Schwarz, Jens; Bellum, John; Atherton, Briggs

    2009-10-01

    To enable laser-based radiography of high energy density physics events on the Z-Accelerator[4,5] at Sandia National Laboratories, a facility known as the Z-Backlighter has been developed. Two Nd:Phosphate glass lasers are used to create x-rays and/or proton beams capable of this radiographic diagnosis: Z-Beamlet (a multi-kilojoule laser operating at 527nm in a few nanoseconds) and Z-Petawatt (a several hundred joule laser operating at 1054nm in the subpicosecond regime) [1,2]. At the energy densities used in these systems, it is necessary to use high damage threshold optical materials, some of which are poorly characterized (especially for the sub-picosecond pulse). For example, Sandia has developed a meter-class dielectric coating capability for system optics. Damage testing can be performed by external facilities for nanosecond 532nm pulses, measuring high reflector coating damage thresholds >80J/cm2 and antireflection coating damage thresholds >20J/cm2 [3]. However, available external testing capabilities do not use femtosecond/picosecond scale laser pulses. To this end, we have constructed a sub-picoseond-laser-based optical damage test system. The damage tester system also allows for testing in a vacuum vessel, which is relevant since many optics in the Z-Backlighter system are used in vacuum. This paper will present the results of laser induced damage testing performed in both atmosphere and in vacuum, with 1054nm sub-picosecond laser pulses. Optical materials/coatings discussed are: bare fused silica and protected gold used for benchmarking; BK7; Zerodur; protected silver; and dielectric optical coatings (halfnia/silica layer pairs) produced by Sandia's in-house meter-class coating capability.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohen, A.R.; Trotzky, M.S.; Pincus, D.

    Hematologic abnormalities in childhood lead poisoning may be due, in part, to the presence of other disorders, such as iron deficiency or thalassemia minor. In order to reassess increased lead burden as a cause of microcytic anemia, we studied 58 children with class III or IV lead poisoning, normal iron stores, and no inherited hemoglobinopathy. Anemia occurred in 12% and microcytosis in 21% of these children. The combination of anemia and microcytosis was found in only one of 58 patients (2%). When only children with class IV lead poisoning were studied, the occurrence of microcytosis increased to 46%. However, themore » combination of microcytosis and anemia was found in only one of these 13 more severely affected patients. Microcytic anemia was similarly uncommon in children with either blood lead concentration greater than or equal to 50 microgram/100 ml. These data indicate that microcytosis and anemia occur much less commonly than previously reported in childhood lead poisoning uncomplicated by other hematologic disorders.« less

  8. Mathematical simulation of the thermal diffusion in dentine irradiated with Nd:YAG laser using finite difference method

    NASA Astrophysics Data System (ADS)

    Moriyama, Eduardo H.; Zangaro, Renato A.; Lobo, Paulo D. d. C.; Villaverde, Antonio G. J. B.; Watanabe-Sei, Ii; Pacheco, Marcos T. T.; Otsuka, Daniel K.

    2002-06-01

    Thermal damage in dental pulp during Nd:YAG laser irradiation have been studied by several researchers; but due to dentin inhomogeneous structure, laser interaction with dentin in the hypersensitivity treatment are not fully understood. In this work, heat distribution profile on human dentine samples irradiated with Nd:YAG laser was simulated at surface and subjacent layers. Calculations were carried out using the Crank-Nicolson's finite difference method. Sixteen dentin samples with 1,5 mm of thickness were evenly distributed into four groups and irradiated with Nd:YAG laser pulses, according to the following scheme: (I) 1 pulse of 900 mJ, (II) 2 pulses of 450 mJ, (III) 3 pulses of 300 mJ, (IV) 6 pulses of 150 mJ; corresponding to a total laser energy of 900 mJ. The pulse interval was 300ms, the pulse duration of 900 ms and irradiated surface area of 0,005 mm2. Laser induced morphological changes in dentin were observed for all the irradiated samples. The heat distribution throughout the dentin layer, from the external dentin surface to the pulpal chamber wall, was calculated for each case, in order to obtain further information about the pulsed Nd:YAG laser-oral hard tissue interaction. The simulation showed significant differences in the final temperature at the pulpal chamber, depending on the exposition time and the energy contained in the laser pulse.

  9. [Analysis of factors related to pulmonary hypertensive crisis in patients with idiopathic pulmonary arterial hypertension].

    PubMed

    Zhang, Chen; Li, Qiangqiang; Zhu, Yan; Gu, Hong

    2014-06-10

    To explore the risk and protective factors for pulmonary hypertensive crisis (PHC) in patients with idiopathic pulmonary arterial hypertension (IPAH). A retrospective study was performed for 65 patients with a diagnosis of IPAH between January 2010 and December 2013. According to clinical manifestations, they were divided into two groups of susceptibility and non-susceptibility to PHC. Clinical and hemodynamic parameters were analyzed in univariate and multivariate manners. Among them, there were 32 males and 33 females with a mean age of (14.4 ± 12.3) (10/12-47.3) years. Twenty-three patients had typical manifestations of PHC and 18 of them were induced by exercises.Univariate analysis revealed that the proportion of patients with World Health Organization (WHO) functional class III-IV in PHC-susceptible group was significantly higher than PHC-nonsusceptible group (60.9% vs 23.8%, P = 0.003) while the percentage of patent foramen ovale in PHC-susceptible group was significantly lower than PHC-nonsusceptible group (8.7% vs 45.2%, P = 0.003).In patients with WHO functional classI-II, hemodynamic variables including the decline of pulmonary arterial pressure and positive rate in vasoreactivity testing in PHC-susceptible group were significantly higher than PHC-nonsusceptible group.In patients with WHO functional class III-IV, baseline pulmonary arterial pressure and mean right atrial pressure in PHC-susceptible group were significantly higher than those in PHC-nonsusceptible group. Multivariate Logistic regression analysis revealed that, for those with WHO functional class III-IV (OR = 23.45, 95%CI: 2.85-193.09) and the decline of systolic pulmonary arterial pressure in vasoreactivity testing (OR = 1.12, 95%CI: 1.04-1.22) were independent risk factors for PHC in IPAH patients while patent foramen ovale (OR = 0.01, 95%CI: 0.00-0.52) was a protective factor. PHC in IPAH patients is correlated with WHO functional class, pulmonary vascular reactivity, baseline pulmonary arterial pressure and patent foramen ovale. And exercise is the most common stimulus to PHC.

  10. Cost-effectiveness of telephonic disease management in heart failure.

    PubMed

    Smith, Brad; Hughes-Cromwick, Paul F; Forkner, Emma; Galbreath, Autumn Dawn

    2008-02-01

    To evaluate the cost-effectiveness of a telephonic disease management (DM) intervention in heart failure (HF). Randomized controlled trial of telephonic DM among 1069 community-dwelling patients with systolic HF (SHF) and diastolic HF performed between 1999 and 2003. The enrollment period was 18 months per subject. Bootstrap-resampled incremental cost-effectiveness ratios (ICERs) were computed and compared across groups. Direct medical costs were obtained from a medical record review that collected records from 92% of patients; 66% of records requested were obtained. Disease management produced statistically significant survival advantages among all patients (17.4 days, P = .04), among patients with New York Heart Association (NYHA) class III/IV symptoms (47.7 days, P = .02), and among patients with SHF (24.2 days, P = .01). Analyses of direct medical and intervention costs showed no cost savings associated with the intervention. For all patients and considering all-cause medical care, the ICER was $146 870 per quality-adjusted life-year (QALY) gained, while for patients with NYHA class III/IV symptoms and patients with SHF, the ICERs were $67 784 and $95 721 per QALY gained, respectively. Costs per QALY gained were $101 120 for all patients, $72 501 for patients with SHF, and $41 348 for patients with NYHA class III/IV symptoms. The intervention was effective but costly to implement and did not reduce utilization. It may not be cost-effective in other broadly representative samples of patients. However, with program cost reductions and proper targeting, this program may produce life-span increases at costs that are less than $100 000 per QALY gained.

  11. Nonlinear pulse compression stage delivering 43-W few-cycle pulses with GW peak-power at 2-μm wavelength

    NASA Astrophysics Data System (ADS)

    Gebhardt, Martin; Gaida, Christian; Heuermann, T.; Stutzki, F.; Jauregui, C.; Antonio-Lopez, J.; Schüuzgen, A.; Amezcua-Correa, R.; Tünnermann, A.; Limpert, J.

    2018-02-01

    In this contribution we demonstrate the nonlinear pulse compression of an ultrafast thulium-doped fiber laser down to 14 fs FWHM duration (sub-3 optical cycles) at a record average power of 43 W and 34.5 μJ pulse energy. To the best of our knowledge, we present the highest average power few-cycle laser source at 2 μm wavelength. This performance level in combination with GW-class peak power makes our laser source extremely interesting for driving high-harmonic generation or for generating mid-infrared frequency combs via intra-pulse frequency down-conversion at an unprecedented average power. The experiments were enabled by an ultrafast thulium-doped fiber laser delivering 110 fs pulses at high repetition rates, and an argon gas-filled antiresonant hollow-core fiber (ARHCF) with excellent transmission and weak anomalous dispersion, leading to the self-compression of the pulses. We have shown that ARHCFs are well-suited for nonlinear pulse compression around 2 μm wavelength and that this concept features excellent power handling capabilities. Based on this result, we discuss the next steps for energy and average power scaling including upscaling the fiber dimensions in order to fully exploit the capabilities of our laser system, which can deliver several GW of peak power. This way, a 100 W-class laser source with mJ-level few-cycle pulses at 2 μm wavelength is feasible in the near future.

  12. Results of fractional ablative facial skin resurfacing with the erbium:yttrium-aluminium-garnet laser 1 week and 2 months after one single treatment in 30 patients.

    PubMed

    Trelles, Mario A; Mordon, Serge; Velez, Mariano; Urdiales, Fernando; Levy, Jean Luc

    2009-03-01

    The erbium:yttrium-aluminium-garnet (Er:YAG) laser has recently been used in the fractional resurfacing of photo-aged skin. Our study evaluated the results after one single session of fractional resurfacing with Er:YAG. Thirty women participated in the study, with an average age of 46 years, skin types from II to IV, and wrinkle grades I to III. The 2,940 nm Er:YAG system used (Pixel, Alma Laser, Israel) had variable pulse durations (1 ms to 2 ms) and energy densities (800 mJ/cm(2) to 1,400 mJ/cm(2)) which, together with the number of passes (four to eight), were selected as a function of wrinkle severity. All patients received only one treatment. Postoperative side effects were evaluated. The number of wrinkles was documented with clinical photography and was scored. Histological assessment was carried out on two patients before and 2 months after treatment. All patients completed the study. Of the patients, 93% reported good or very good improvement of the degree of their wrinkles, with a satisfaction index of 83%. Pain was not a problem during treatment, and there were no side effects except for in one phototype IV patient, who had hyperpigmentation. Histology 2 months after the single treatment demonstrated younger morphology of both the epidermis and dermis, with improvement of the pretreatment typical elastotic appearance. At the parameters used in our study, only one treatment session of Er:YAG laser could achieve effective skin rejuvenation, with effects recognized in both the dermis and, more importantly, the epidermis. This regimen offers an interesting alternative to the conventional approach of multi-session fractional resurfacing.

  13. Enhanced removal of Enterococcus faecalis biofilms in the root canal using sodium hypochlorite plus photon-induced photoacoustic streaming: an in vitro study.

    PubMed

    Al Shahrani, Mohammed; DiVito, Enrico; Hughes, Christopher V; Nathanson, Dan; Huang, George T-J

    2014-05-01

    The purpose of this study was to determine the effectiveness of laser-activated irrigation by photon-induced photoacoustic streaming (PIPS) using Er:YAG laser energy in decontaminating heavily colonized root canal systems in vitro. Extracted single-rooted human teeth (n=60) were mechanically and chemically prepared, sterilized, inoculated with Enterococcus faecalis for 3 weeks, and randomly assigned to four groups (n=15): Group I (control, no decontamination), Group II (PIPS+6% NaOCl), Group III (PIPS+saline), and Group IV (6% NaOCl). PIPS settings were all preset to 50 μsec pulse, 20 mJ, 15 Hz, for an average power of 0.3 W. After decontamination, the remaining live microbes from all specimens were collected and recovered via plate counting of the colony-forming units (CFUs). Randomized root canal surfaces were examined with scanning electron microscopy and confocal laser microscopy. Mean variance and Dunnett's t test (post-hoc test) comparisons were used to compare mean scores for the three groups with the control group. The CFU analysis showed the following measurements (mean±SE): Group I (control), 336.8±1.8; Group II (PIPS+NaOCl), 0.27±0.21; Group III (PIPS+saline), 225.0±21; and Group IV (NaOCl), 46.9±20.29. Group II had significantly lower CFUs than any other groups (p<0.05). Both imaging analyses confirmed levels of remaining bacteria on examined root surfaces. The use of the PIPS system along with NaOCl showed the most efficient eradication of the bacterial biofilm. It appears that laser-activated irrigation (LAI) utilizing PIPS may enhance the disinfection of the root canal system.

  14. Enhanced Removal of Enterococcus faecalis Biofilms in the Root Canal Using Sodium Hypochlorite Plus Photon-Induced Photoacoustic Streaming: An In Vitro Study

    PubMed Central

    Al Shahrani, Mohammed; DiVito, Enrico; Hughes, Christopher V.; Nathanson, Dan

    2014-01-01

    Abstract Objective: The purpose of this study was to determine the effectiveness of laser-activated irrigation by photon-induced photoacoustic streaming (PIPS) using Er:YAG laser energy in decontaminating heavily colonized root canal systems in vitro. Materials and methods: Extracted single-rooted human teeth (n=60) were mechanically and chemically prepared, sterilized, inoculated with Enterococcus faecalis for 3 weeks, and randomly assigned to four groups (n=15): Group I (control, no decontamination), Group II (PIPS+6% NaOCl), Group III (PIPS+saline), and Group IV (6% NaOCl). PIPS settings were all preset to 50 μsec pulse, 20 mJ, 15 Hz, for an average power of 0.3 W. After decontamination, the remaining live microbes from all specimens were collected and recovered via plate counting of the colony-forming units (CFUs). Randomized root canal surfaces were examined with scanning electron microscopy and confocal laser microscopy. Mean variance and Dunnett's t test (post-hoc test) comparisons were used to compare mean scores for the three groups with the control group. Results: The CFU analysis showed the following measurements (mean±SE): Group I (control), 336.8±1.8; Group II (PIPS+NaOCl), 0.27±0.21; Group III (PIPS+saline), 225.0±21; and Group IV (NaOCl), 46.9±20.29. Group II had significantly lower CFUs than any other groups (p<0.05). Both imaging analyses confirmed levels of remaining bacteria on examined root surfaces. Conclusions: The use of the PIPS system along with NaOCl showed the most efficient eradication of the bacterial biofilm. It appears that laser-activated irrigation (LAI) utilizing PIPS may enhance the disinfection of the root canal system. PMID:24717113

  15. Reconstructive transoral laser microsurgery for posterior glottic web with stenosis.

    PubMed

    Atallah, Ihab; Manjunath, M Krishniah; Omari, Ahmad Al; Righini, Christian Adrien; Castellanos, Paul F

    2017-03-01

    To demonstrate that reconstructive transoral laser microsurgical (R-TLM) techniques can be used for the treatment of symptomatic laryngeal posterior glottic web-based stenosis (PGWS) in a large cohort of patients utilizing a postcricoid mucosal advancement flap (PCMAF). Retrospective cohort review. A consecutive series of patients with PGWS who underwent R-TLM using a PCMAF were reviewed for outcomes. After laser excision of the PGWS scar and mobilization of fixed cricoarytenoid joints, a PCMAF was raised using microinstruments and a scanning free-beam CO 2 laser. The flap was advanced and attached over the scar bed using a technique with multiple novel features that make it easy to adopt. Fifty-two patients were treated. Of the cases, 42.3% had a tracheostomy at presentation with grade II to IV PGWS, and 46% of cases had grade III to IV PGWS. In all cases, R-TLM was the only treatment approach. No open reconstructions were performed. No airway stents were used. Patients without tracheostomy, regardless of the grade of stenosis, did not require a tracheostomy to undergo this operation. All tracheostomy patients were successfully decannulated. All patients without a tracheostomy had significant improvement of their respiratory symptoms on the Dyspnea Index (mean Δ = 14.75, P value <.01). RTLM using the PCMAF is a feasible, safe, and effective alternative to open approaches for airway reconstruction for PGWS. This novel transoral technique includes a much simpler endoscopic suturing alternative to knot tying among other new features. It is reproducible and reliable for laryngologists familiar with laryngeal microsurgery. 4. Laryngoscope, 127:685-690, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Adjuvant radiotherapy after transoral laser microsurgery for advanced squamous carcinoma of the head and neck

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pradier, Olivier; Christiansen, Hans; Schmidberger, Heinz

    Purpose: To evaluate the efficacy of an adjuvant radiotherapy after transoral laser microsurgery for advanced squamous cell carcinoma of the head and neck and to show that a less invasive surgery with organ preservation in combination with radiotherapy is an alternative to a radical treatment. Patients and Methods: Between 1987 and 2000, 208 patients with advanced squamous cell carcinoma of the head and neck were treated with postoperative radiotherapy after surgical CO{sub 2} laser resection. Primary sites included oral cavity, 38; oropharynx, 88; larynx, 36; hypopharynx, 46. Disease stages were as follows: Stage III, 40 patients; Stage IV, 168 patients.more » Before 1994, the treatment consisted of a split-course radiotherapy with carboplatinum (Treatment A). After 1994, the patients received a conventional radiotherapy (Treatment B). Results: Patients had 5-year locoregional control and disease-specific survival (DSS) rates of 68% and 48%, respectively. The 5-year DSS was 70% and 44% for Stages III and IV, respectively (p = 0.00127). Patients treated with a hemoglobin level greater or equal to 13.5 g/dL before radiotherapy had a 5-year DSS of 55% as compared with 39% for patients treated with a hemoglobin level greater than 13.5 g/dL (p = 0.0054). Conclusion: In this series of patients with advanced head-and-neck tumors, transoral laser surgery in combination with adjuvant radiotherapy resulted in locoregional control and DSS rates similar to those reported for radical surgery followed by radiotherapy. Treatment B has clearly been superior to Treatment A. A further improvement of our treatment regimen might be expected by the combination of adjuvant radiotherapy with concomitant platinum-based chemotherapy.« less

  17. Evaluating the potential for internal injuries from a pulsed 3.8-micron laser

    NASA Astrophysics Data System (ADS)

    Johnson, Thomas E.; Fitzhugh, Dawn C.; McPherson, Nicole; Winston, Golda C. H.; Winston, Tridaugh D.; Randolph, Donald Q.

    2005-04-01

    The goal of this study is to determine if a high energy laser pulse can cause internal injury that cannot be grossly visualized. High power lasers are currently in development such as the Medical Free Electron Laser (MFEL), the Anti-Ballistic Laser (ABL) and the Tactical High Energy Laser (THEL) and the potential exists for human exposure. Little is known about the effects of these high output lasers on internal organs when a thoracic exposure occurs. This study utilized a 3.8 micron single 8 microsecond pulse laser for all exposures. Yucatan miniature pigs were exposed to a single pulse over the sternum. In addition, some animals were also exposed in the axillary region. Creatine phosphokinase (CPK) and troponin levels were measured prior to and post exposure to assess cardiac muscle damage. Gross and histologic changes were determined for the porcine skin, lung tissue, and cardiac muscle. This study explores if a greater than class 4 laser classification is warranted based on the potential for thoracic injury.

  18. Transition-metal doped sulfide, selenide, and telluride laser crystal and lasers

    DOEpatents

    Krupke, W.F.; Page, R.H.; DeLoach, L.D.; Payne, S.A.

    1996-07-30

    A new class of solid state laser crystals and lasers are formed of transition metal doped sulfide, selenide, and telluride host crystals which have four fold coordinated substitutional sites. The host crystals include II-VI compounds. The host crystal is doped with a transition metal laser ion, e.g., chromium, cobalt or iron. In particular, Cr{sup 2+}-doped ZnS and ZnSe generate laser action near 2.3 {micro}m. Oxide, chloride, fluoride, bromide and iodide crystals with similar structures can also be used. Important aspects of these laser materials are the tetrahedral site symmetry of the host crystal, low excited state absorption losses and high luminescence efficiency, and the d{sup 4} and d{sup 6} electronic configurations of the transition metal ions. The same materials are also useful as saturable absorbers for passive Q-switching applications. The laser materials can be used as gain media in amplifiers and oscillators; these gain media can be incorporated into waveguides and semiconductor lasers. 18 figs.

  19. Transition-metal doped sulfide, selenide, and telluride laser crystal and lasers

    DOEpatents

    Krupke, William F.; Page, Ralph H.; DeLoach, Laura D.; Payne, Stephen A.

    1996-01-01

    A new class of solid state laser crystals and lasers are formed of transition metal doped sulfide, selenide, and telluride host crystals which have four fold coordinated substitutional sites. The host crystals include II-VI compounds. The host crystal is doped with a transition metal laser ion, e.g., chromium, cobalt or iron. In particular, Cr.sup.2+ -doped ZnS and ZnSe generate laser action near 2.3 .mu.m. Oxide, chloride, fluoride, bromide and iodide crystals with similar structures can also be used. Important aspects of these laser materials are the tetrahedral site symmetry of the host crystal, low excited state absorption losses and high luminescence efficiency, and the d.sup.4 and d.sup.6 electronic configurations of the transition metal ions. The same materials are also useful as saturable absorbers for passive Q-switching applications. The laser materials can be used as gain media in amplifiers and oscillators; these gain media can be incorporated into waveguides and semiconductor lasers.

  20. Progress in coherent lithography using table-top extreme ultraviolet lasers

    NASA Astrophysics Data System (ADS)

    Li, Wei

    Nanotechnology has drawn a wide variety of attention as interesting phenomena occurs when the dimension of the structures is in the nanometer scale. The particular characteristics of nanoscale structures had enabled new applications in different fields in science and technology. Our capability to fabricate these nanostructures routinely for sure will impact the advancement of nanoscience. Apart from the high volume manufacturing in semiconductor industry, a small-scale but reliable nanofabrication tool can dramatically help the research in the field of nanotechnology. This dissertation describes alternative extreme ultraviolet (EUV) lithography techniques which combine table-top EUV laser and various cost-effective imaging strategies. For each technique, numerical simulations, system design, experiment result and its analysis will be presented. In chapter II, a brief review of the main characteristics of table-top EUV lasers will be addressed concentrating on its high power and large coherence radius that enable the lithography application described herein. The development of a Talbot EUV lithography system which is capable of printing 50nm half pitch nanopatterns will be illustrated in chapter III. A detailed discussion of its resolution limit will be presented followed by the development of X-Y-Z positioning stage, the fabrication protocol for diffractive EUV mask, and the pattern transfer using self- developed ion beam etching, and the dose control unit. In addition, this dissertation demonstrated the capability to fabricate functional periodic nanostructures using Talbot EUV lithography. After that, resolution enhancement techniques like multiple exposure, displacement Talbot EUV lithography, fractional Talbot EUV lithography, and Talbot lithography using 18.9nm amplified spontaneous emission laser will be demonstrated. Chapter IV will describe a hybrid EUV lithography which combines the Talbot imaging and interference lithography rendering a high resolution interference pattern whose lattice is modified by a custom designed Talbot mask. In other words, this method enables filling the arbitrary Talbot cell with ultra-fine interference nanofeatures. Detailed optics modeling, system design and experiment results using He-Ne laser and table top EUV laser are included. The last part of chapter IV will analyze its exclusive advantages over traditional Talbot or interference lithography.