Bunka, Maruta; Müller, Cristina; Vermeulen, Christiaan; Haller, Stephanie; Türler, Andreas; Schibli, Roger; van der Meulen, Nicholas P
2016-04-01
PET is the favored nuclear imaging technique because of the high sensitivity and resolution it provides, as well as the possibility for quantification of accumulated radioactivity. (44)Sc (T1/2=3.97h, Eβ(+)=632keV) was recently proposed as a potentially interesting radionuclide for PET. The aim of this study was to investigate the image quality, which can be obtained with (44)Sc, and compare it with five other, frequently employed PET nuclides using Derenzo phantoms and a small-animal PET scanner. The radionuclides were produced at the medical cyclotron at CRS, ETH Zurich ((11)C, (18)F), at the Injector II research cyclotron at CRS, PSI ((64)Cu, (89)Zr, (44)Sc), as well as via a generator system ((68)Ga). Derenzo phantoms, containing solutions of each of these radionuclides, were scanned using a GE Healthcare eXplore VISTA small-animal PET scanner. The image resolution was determined for each nuclide by analysis of the intensity signal using the reconstructed PET data of a hole diameter of 1.3mm. The image quality of (44)Sc was compared to five frequently-used PET radionuclides. In agreement with the positron range, an increasing relative resolution was determined in the sequence of (68)Ga<(44)Sc<(89)Zr<(11)C<(64)Cu<(18)F. The performance of (44)Sc was in agreement with the theoretical expectations based on the energy of the emitted positrons. Copyright © 2016 Elsevier Ltd. All rights reserved.
Beam-on imaging of short-lived positron emitters during proton therapy
NASA Astrophysics Data System (ADS)
Buitenhuis, H. J. T.; Diblen, F.; Brzezinski, K. W.; Brandenburg, S.; Dendooven, P.
2017-06-01
In vivo dose delivery verification in proton therapy can be performed by positron emission tomography (PET) of the positron-emitting nuclei produced by the proton beam in the patient. A PET scanner installed in the treatment position of a proton therapy facility that takes data with the beam on will see very short-lived nuclides as well as longer-lived nuclides. The most important short-lived nuclide for proton therapy is 12N (Dendooven et al 2015 Phys. Med. Biol. 60 8923-47), which has a half-life of 11 ms. The results of a proof-of-principle experiment of beam-on PET imaging of short-lived 12N nuclei are presented. The Philips Digital Photon Counting Module TEK PET system was used, which is based on LYSO scintillators mounted on digital SiPM photosensors. A 90 MeV proton beam from the cyclotron at KVI-CART was used to investigate the energy and time spectra of PET coincidences during beam-on. Events coinciding with proton bunches, such as prompt gamma rays, were removed from the data via an anti-coincidence filter with the cyclotron RF. The resulting energy spectrum allowed good identification of the 511 keV PET counts during beam-on. A method was developed to subtract the long-lived background from the 12N image by introducing a beam-off period into the cyclotron beam time structure. We measured 2D images and 1D profiles of the 12N distribution. A range shift of 5 mm was measured as 6 ± 3 mm using the 12N profile. A larger, more efficient, PET system with a higher data throughput capability will allow beam-on 12N PET imaging of single spots in the distal layer of an irradiation with an increased signal-to-background ratio and thus better accuracy. A simulation shows that a large dual panel scanner, which images a single spot directly after it is delivered, can measure a 5 mm range shift with millimeter accuracy: 5.5 ± 1.1 mm for 1 × 108 protons and 5.2 ± 0.5 mm for 5 × 108 protons. This makes fast and accurate feedback on the dose delivery during treatment possible.
Nagaoka, Hiroaki; Watanabe, Hiroshi; Yamaguchi, Ichiro; Fujibuchi, Toshioh; Kida, Tetsuo; Tanaka, Shinji
2009-12-20
A clearance system for medical radioactive solid waste has not yet been implemented in Japan. Since 2004 new regulations have allowed institutions using positron emission tomography(PET)to handle totally decayed radioactive waste as non-radioactive waste after decay-in-storage. It was expected that this new regulation would mediate the installation of clearance systems in Japan. In order to assess the current situation of radiation safety management in PET institutions, we conducted a nationwide survey. The study design was a cross-sectional descriptive study conducted by questionnaire. The subjects of this survey were all the PET institutions in Japan. Among 224 institutes, 128 institutes are equipped with cyclotrons and 96 institutes are not. The number of returned questionnaires was 138. Among institutes that are using delivered radiopharmaceuticals, 80% treat their waste as non-radioactive according to the new regulation. The impact of new regulations for reducing radioactive waste in PET institutes without a cyclotron was estimated at about $400 thousand per year. The main concern of medical institutes was assessment of the contamination caused by by-products of radioactive nuclides generated in target water during the operation of a cyclotron. It was thought that a rational rule based on scientific risk management should be established because these by-products of radioactive nuclides are negligible for radiation safety. New regulation has had a good influence on medical PET institutes, and it is expected that a clearance system for medical radioactive waste will be introduced in the near future, following these recent experiences in PET institutes.
Noto, Benjamin; Auf der Springe, Katharina; Huss, Sebastian; Allkemper, Thomas; Stegger, Lars
2018-06-01
Ga-PSMA-11 PET/CT was performed in a 74-year-old man because of biochemical recurrence of prostate cancer following radiation therapy of the prostate gland 24 months earlier. Besides focal nuclide accumulation in the prostate gland suggestive of local recurrence, PET scan revealed no further pathologic uptake. However, CT showed multiple pulmonic nodules suggestive of metastases. Thoracotomy and pathologic examination revealed the nodules to be prostate cancer metastasis. Furthermore, immunohistochemical staining with PSMA antibodies demonstrated a virtual lack of PSMA expression. This case demonstrates the possibility of PSMA-negative metastases of prostate cancer an important pitfall that should be known to physicians interpreting PSMA PET.
The production of [124I]iodine and [86Y]yttrium.
Schmitz, Jochen
2011-05-01
The use of paired tracers such as (124)I/(131)I and (86)Y/(90)Y allows pretherapy PET imaging with positron emitting radioisotopes of the same element as used for therapy. Whereas nowadays most therapy nuclides are produced by reactors or generators, the production of the corresponding PET isotopes requires the irradiation of adequate targets using particle accelerators such as cyclotrons. This paper describes the production routes for (124)I and (86)Y.
[Current trends in using PET radiopharmaceuticals for diagnostics in oncology].
Adam, J; Kadeřávek, J; Kužel, F; Vašina, J; Rehák, Z
2014-01-01
Nuclear medicine is an important field of modern medicine, particularly thanks to its role in in vivo imaging of important processes in human organism. This is possible thanks to the use of radiopharmaceuticals, specific substances labeled by radioactive nuclide, its distribution in the body can be visualized by specialized scanners and, based on the knowledge of physiological patterns, dia-gnosis can be determined. Positron emission tomography (PET) is a modern and in many ways indispensable method of nuclear medicine. The spectrum of radiopharmaceuticals available in recent years is broadening thanks to a coordinated effort of manufacturers of synthesis equipment, chemists and potential users - physicians. This review focuses on the development in the PET radiopharmaceutical field in the last five years, with an emphasis on oncological applications of PET.
SU-E-I-98: PET/CT's Most-Cited 50 Articles since 2000: A Bibliometric Analysis of Classics.
Sayed, G
2012-06-01
Despite its relatively recent introduction to clinical practice, PET/CT has gained wide acceptance both in diagnostic and therapeutic applications. Scientific publication in PET/CT has also experienced significant development since its introduction. Bibliometric analyses allow an understanding of how this publication trend has developed at an aggregated level. Citation analysis is one of the most widely used bibliometric tools of scientometrics. Analysis of classics, defined as an articles with 100 or more citations, is common in the biomedical sciences as it reflects an article's influence in its professional and scientific community. Our objective was to identify the 50 most frequently cited classic articles in PET/CT in the past 10 years. The 50 most-cited PET/CT articles were identified by searching ISI's Web of Knowledge and Pubmed databases for all related publications from 2000 through 2010. Articles were evaluated for several characteristics such as author(s), institution, country of origin, publication year, type, and number of citations. An unadjusted categorical analysis was performed to compare all articles published in the search period. The search yielded a cumulative total of 22,554 entries for the publication period, of which 15,943 were original research articles. The 50 most-cited articles were identified from the latter sum and selected out of 73 classics. The number of citations for the top 50 classics ranged from 114 to 700. PET/CT classics appeared in three general and 12 core journals. The majority of the classics were in oncologic applications of PET/CT (62%). Articles related to diagnostic topics were 6%. The rest were focused on physics and instrumentation 24% and other basic sciences 16%. Despite its relatively short history PET/CT accumulated 73 classic articles in a decade. Such information is of importance to researchers and those who wish to study the scientific development in the field. © 2012 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Shimchuk, G.; Shimchuk, Gr; Pakhomov, G.; Avalishvili, G.; Zavrazhnov, G.; Polonsky-Byslaev, I.; Fedotov, A.; Polozov, P.
2017-01-01
One of the prospective directions of PET development is using generator positron radiating nuclides [1,2]. Introduction of this technology is financially promising, since it does not require expensive special accelerator and radiochemical laboratory in the medical institution, which considerably reduces costs of PET diagnostics and makes it available to more patients. POZITOM-PRO RPC LLC developed and produced an 82Sr-82Rb generator, an automated injection system, designed for automatic and fully-controlled injections of 82RbCl produced by this generator, automated radiopharmaceutical synthesis units based on generated 68Ga produced using a domestically-manufactured 68Ge-68Ga generator for preparing two pharmaceuticals: Ga-68-DOTA-TATE and Vascular Ga-68.
Characterization of 41Ar production in air at a PET cyclotron facility
NASA Astrophysics Data System (ADS)
Cicoria, Gianfranco; Cesarini, Francesco; Infantino, Angelo; Vichi, Sara; Zagni, Federico; Marengo, Mario
2017-06-01
In the production of Positron Emission Tomography (PET) nuclides at a medical cyclotron facility 41Ar (T1/2 = 109.34 m) is produced by the activation of air due to the neutron flux, according to the 40Ar(n, γ)41Ar reaction. In this work, we describe a relatively inexpensive and readily reproducible methodology of air sampling that can be used for quantification of 41Ar during the routine production of PET nuclides. We report the results of an extensive measurement campaign in the cyclotron bunker and in the ducts of the ventilation system, before and after final filtering of the extracted air. Air Samples were analyzed using a gamma-ray spectrometry system equipped with HPGe detector, with proper correction of the efficiency calibration to account for the samples density. The results of measurement were then used to evaluate the Total Effective Dose (TED) to the population living in the surrounding areas, due to routine emissions in the operation of the cyclotron. The average 41Ar saturation yield per one liter of air emitted in the environment resulted to be (0.044 ± 0.007) Bq/(μA ṡ dm3). The maximum value of TED for the critical group of the population, even considering an overestimated workload, was less than 0.19 μSv/year, well below the level of radiological relevance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kabalka, G. W.
2005-06-28
The primary objective of the project was the development of in vivo methods for the detection and evaluation of tumors in humans. The project was focused on utilizing positron emission tomography (PET) to monitor the distribution and pharamacokinetics of a current boron neutron capture therapy (BNCT) agent, p-boronophenylalanine (BPA) by labeling it with a fluorine-18, a positron emitting isotope. The PET data was then used to develop enhanced treatment planning protocols. The study also involved the synthesis of new tumor selective BNCTagents that could be labeled with radioactive nuclides for the in vivo detection of boron.
2018-04-12
Classical Hodgkin Lymphoma; Lymphocyte-Depleted Classical Hodgkin Lymphoma; Lymphocyte-Rich Classical Hodgkin Lymphoma; Mixed Cellularity Classical Hodgkin Lymphoma; Nodular Sclerosis Classical Hodgkin Lymphoma
Rohling, Heide; Sihver, Lembit; Priegnitz, Marlen; Enghardt, Wolfgang; Fiedler, Fine
2014-01-01
Therapeutic irradiation with protons and ions is advantageous over radiotherapy with photons due to its favorable dose deposition. Additionally, ion beams provide a higher relative biological effectiveness than photons. For this reason, an improved treatment of deep-seated tumors is achieved and normal tissue is spared. However, small deviations from the treatment plan can have a large impact on the dose distribution. Therefore, a monitoring is required to assure the quality of the treatment. Particle therapy positron emission tomography (PT-PET) is the only clinically proven method which provides a non-invasive monitoring of dose delivery. It makes use of the β+-activity produced by nuclear fragmentation during irradiation. In order to evaluate these PT-PET measurements, simulations of the β+-activity are necessary. Therefore, it is essential to know the yields of the β+-emitting nuclides at every position of the beam path as exact as possible. We evaluated the three-dimensional Monte-Carlo simulation tool PHITS (version 2.30) [ 1] and the 1D deterministic simulation tool HIBRAC [ 2] with respect to the production of β+-emitting nuclides. The yields of the most important β+-emitting nuclides for carbon, lithium, helium and proton beams have been calculated. The results were then compared with experimental data obtained at GSI Helmholtzzentrum für Schwerionenforschung Darmstadt, Germany. GEANT4 simulations provide an additional benchmark [ 3]. For PHITS, the impact of different nuclear reaction models, total cross-section models and evaporation models on the β+-emitter production has been studied. In general, PHITS underestimates the yields of positron-emitters and cannot compete with GEANT4 so far. The β+-emitters calculated with an extended HIBRAC code were in good agreement with the experimental data for carbon and proton beams and comparable to the GEANT4 results, see [ 4] and Fig. 1. Considering the simulation results and its speed compared with three-dimensional Monte-Carlo tools, HIBRAC is a good candidate for the implementation in clinical routine PT-PET. Fig 1.Depth-dependent yields of the production of 11C and 15O during proton irradiation of a PMMA target with 140 MeV [ 4].
NASA Astrophysics Data System (ADS)
Sun, Aixia; Liu, Xiang; Tang, Ganghua
2017-12-01
Tumor cells have an increased nutritional demand for amino acids(AAs) to satisfy their rapid proliferation. Positron-emitting nuclide labeled AAs are interesting probes and are of great importance for imaging tumors using positron emission tomography (PET). Carbon-11 and fluorine-18 labeled AAs include the [1-11C] amino acids, labeling alpha-C- amino acids, the branched-chain of amino acids and N-substituted carbon-11 labeled amino acids. These tracers target protein synthesis or amino acid(AA) transport, and their uptake mechanism mainly involves AA transport. AA PET tracers have been widely used in clinical settings to image brain tumors, neuroendocrine tumors, prostate cancer, breast cancer, non–small cell lung cancer (NSCLC) and hepatocellular carcinoma. This review focuses on the fundamental concepts and the uptake mechanism of AAs, AA PET tracers and their clinical applications.
Twelve automated thresholding methods for segmentation of PET images: a phantom study.
Prieto, Elena; Lecumberri, Pablo; Pagola, Miguel; Gómez, Marisol; Bilbao, Izaskun; Ecay, Margarita; Peñuelas, Iván; Martí-Climent, Josep M
2012-06-21
Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical (18)F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools.
Twelve automated thresholding methods for segmentation of PET images: a phantom study
NASA Astrophysics Data System (ADS)
Prieto, Elena; Lecumberri, Pablo; Pagola, Miguel; Gómez, Marisol; Bilbao, Izaskun; Ecay, Margarita; Peñuelas, Iván; Martí-Climent, Josep M.
2012-06-01
Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical 18F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools.
Yao, Rutao; Ramachandra, Ranjith M.; Mahajan, Neeraj; Rathod, Vinay; Gunasekar, Noel; Panse, Ashish; Ma, Tianyu; Jian, Yiqiang; Yan, Jianhua; Carson, Richard E.
2012-01-01
To achieve optimal PET image reconstruction through better system modeling, we developed a system matrix that is based on the probability density function for each line of response (LOR-PDF). The LOR-PDFs are grouped by LOR-to-detector incident angles to form a highly compact system matrix. The system matrix was implemented in the MOLAR list mode reconstruction algorithm for a small animal PET scanner. The impact of LOR-PDF on reconstructed image quality was assessed qualitatively as well as quantitatively in terms of contrast recovery coefficient (CRC) and coefficient of variance (COV), and its performance was compared with a fixed Gaussian (iso-Gaussian) line spread function. The LOR-PDFs of 3 coincidence signal emitting sources, 1) ideal positron emitter that emits perfect back-to-back γ rays (γγ) in air; 2) fluorine-18 (18F) nuclide in water; and 3) oxygen-15 (15O) nuclide in water, were derived, and assessed with simulated and experimental phantom data. The derived LOR-PDFs showed anisotropic and asymmetric characteristics dependent on LOR-detector angle, coincidence emitting source, and the medium, consistent with common PET physical principles. The comparison of the iso-Gaussian function and LOR-PDF showed that: 1) without positron range and acolinearity effects, the LOR-PDF achieved better or similar trade-offs of contrast recovery and noise for objects of 4-mm radius or larger, and this advantage extended to smaller objects (e.g. 2-mm radius sphere, 0.6-mm radius hot-rods) at higher iteration numbers; and 2) with positron range and acolinearity effects, the iso-Gaussian achieved similar or better resolution recovery depending on the significance of positron range effect. We conclude that the 3-D LOR-PDF approach is an effective method to generate an accurate and compact system matrix. However, when used directly in expectation-maximization based list-mode iterative reconstruction algorithms such as MOLAR, its superiority is not clear. For this application, using an iso-Gaussian function in MOLAR is a simple but effective technique for PET reconstruction. PMID:23032702
Prieto-Peña, Diana; Martínez-Rodríguez, Isabel; Loricera, Javier; Banzo, Ignacio; Calderón-Goercke, Mónica; Calvo-Río, Vanesa; González-Vela, Carmen; Corrales, Alfonso; Castañeda, Santos; Blanco, Ricardo; Hernández, José L; González-Gay, Miguel Á
2018-05-18
Polymyalgia rheumatica (PMR) is often the presenting manifestation of giant cell arteritis (GCA). Fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) scan often discloses the presence of large vessel vasculitis (LVV) in PMR patients. We aimed to identify predictive factors of a positive PET/CT scan for LVV in patients classified as having isolated PMR according to well-established criteria. A set of consecutive patients with PMR from a single hospital were assessed. All of them underwent PET/CT scan between January 2010 and February 2018 based on clinical considerations. Patients with PMR associated to other diseases, including those with cranial features of GCA, were excluded. The remaining patients were categorized in classic PMR (if fulfilled the 2012 EULAR/ACR classification criteria at disease diagnosis; n = 84) or atypical PMR (who did not fulfill these criteria; n = 16). Only information on patients with classic PMR was assessed. The mean age of the 84 patients (51 women) with classic PMR was 71.4 ± 9.2 years. A PET/CT scan was positive in 51 (60.7%). Persistence of classic PMR symptoms was the most common reason to perform a PET/CT scan. Nevertheless, patients with positive PET/CT scan often had unusual symptoms. The best set of predictors of a positive PET/CT scan were bilateral diffuse lower limb pain (OR = 8.8, 95% CI: 1.7-46.3; p = 0.01), pelvic girdle pain (OR = 4.9, 95% CI: 1.50-16.53; p = 0.01) and inflammatory low back pain (OR = 4.7, 95% CI: 1.03-21.5; p = 0.04). Inflammatory low back pain, pelvic girdle and diffuse lower limb pain are predictors of positive PET/CT scan for LVV in PMR. Copyright © 2018 Elsevier Inc. All rights reserved.
Fluorine-18 Radiochemistry, Labeling Strategies and Synthetic Routes
2015-01-01
Fluorine-18 is the most frequently used radioisotope in positron emission tomography (PET) radiopharmaceuticals in both clinical and preclinical research. Its physical and nuclear characteristics (97% β+ decay, 109.7 min half-life, 635 keV positron energy), along with high specific activity and ease of large scale production, make it an attractive nuclide for radiochemical labeling and molecular imaging. Versatile chemistry including nucleophilic and electrophilic substitutions allows direct or indirect introduction of 18F into molecules of interest. The significant increase in 18F radiotracers for PET imaging accentuates the need for simple and efficient 18F-labeling procedures. In this review, we will describe the current radiosynthesis routes and strategies for 18F labeling of small molecules and biomolecules. PMID:25473848
Le, Van So; Do, Zoe Phuc-Hien; Le, Minh Khoi; Le, Vicki; Le, Natalie Nha-Truc
2014-06-10
Methods of increasing the performance of radionuclide generators used in nuclear medicine radiotherapy and SPECT/PET imaging were developed and detailed for 99Mo/99mTc and 68Ge/68Ga radionuclide generators as the cases. Optimisation methods of the daughter nuclide build-up versus stand-by time and/or specific activity using mean progress functions were developed for increasing the performance of radionuclide generators. As a result of this optimisation, the separation of the daughter nuclide from its parent one should be performed at a defined optimal time to avoid the deterioration in specific activity of the daughter nuclide and wasting stand-by time of the generator, while the daughter nuclide yield is maintained to a reasonably high extent. A new characteristic parameter of the formation-decay kinetics of parent/daughter nuclide system was found and effectively used in the practice of the generator production and utilisation. A method of "early elution schedule" was also developed for increasing the daughter nuclide production yield and specific radioactivity, thus saving the cost of the generator and improving the quality of the daughter radionuclide solution. These newly developed optimisation methods in combination with an integrated elution-purification-concentration system of radionuclide generators recently developed is the most suitable way to operate the generator effectively on the basis of economic use and improvement of purposely suitable quality and specific activity of the produced daughter radionuclides. All these features benefit the economic use of the generator, the improved quality of labelling/scan, and the lowered cost of nuclear medicine procedure. Besides, a new method of quality control protocol set-up for post-delivery test of radionuclidic purity has been developed based on the relationship between gamma ray spectrometric detection limit, required limit of impure radionuclide activity and its measurement certainty with respect to optimising decay/measurement time and product sample activity used for QC quality control. The optimisation ensures a certainty of measurement of the specific impure radionuclide and avoids wasting the useful amount of valuable purified/concentrated daughter nuclide product. This process is important for the spectrometric measurement of very low activity of impure radionuclide contamination in the radioisotope products of much higher activity used in medical imaging and targeted radiotherapy.
Microfluidic 68Ga-labeling: a proof of principle study.
Pfaff, Sarah; Philippe, Cecile; Pichler, Verena; Hacker, Marcus; Mitterhauser, Markus; Wadsak, Wolfgang
2018-05-01
Positron emission tomography (PET) as a tool for molecular imaging of cancer has gained huge interest in the last few years. Gallium-68 is a popular PET nuclide due to its favorable characteristics, like advantageous half-life (68 min) and independency of a cyclotron on-site for its production. Accordingly, several 68Ga-complexes for cancer imaging via PET have been made available during the last few years. In this work, 68Ga-labeled compounds were synthesized applying a commercially available microfluidic device for the first time. Therefore, a proof of principle study using three important radiotracers, [68Ga]Ga-PSMA-11, [68Ga]Ga-NODAGA-RGDyk and [68Ga]Ga-DOTA-NOC, was designed. For all three radioligands, various synthesis parameters were evaluated and the feasibility of using a continuous flow reactor was assessed. All of the precursors were successfully radiolabeled with a radiochemical yield higher than 80%, proving the principle that a microfluidic set-up is a suitable approach for the production of 68Ga-labeled tracers.
Clinical evaluation of the radiolanthanide terbium-152: first-in-human PET/CT with 152Tb-DOTATOC.
Baum, Richard P; Singh, Aviral; Benešová, Martina; Vermeulen, Christiaan; Gnesin, Silvano; Köster, Ulli; Johnston, Karl; Müller, Dirk; Senftleben, Stefan; Kulkarni, Harshad R; Türler, Andreas; Schibli, Roger; Prior, John O; van der Meulen, Nicholas P; Müller, Cristina
2017-10-31
The existence of theragnostic pairs of radionuclides allows the preparation of radiopharmaceuticals for diagnostic and therapeutic purposes. Radiolanthanides, such as 177 Lu, are successfully used for therapeutic purposes; however, a perfect diagnostic match is currently not available for clinical use. A unique, multi-disciplinary study was performed using 152 Tb (T 1/2 = 17.5 h, Eβ + average = 1140 keV, Iβ + = 20.3%), which resulted in the first-in-human PET/CT images with this promising radionuclide. For this purpose, 152 Tb was produced via a spallation process followed by mass separation at ISOLDE, CERN. The chemical separation and quality control, performed at PSI, resulted in a pure product in sufficient yields. Clinical PET phantom studies revealed an increased image noise level, because of the smaller β + branching ratio of 152 Tb as compared to standard PET nuclides at matched activity concentrations; however, the expected recovery would be comparable at matched signal-to-noise ratios in clinical PET. 152 Tb was used for labeling DOTATOC, at Zentralklinik Bad Berka, and administered to a patient for a first-in-human clinical study. PET scans were performed over a period of 24 h, allowing the visualization of even small metastases with increased tumor-to-background contrast over time. Based on the results obtained in this work, it can be deduced that PET/CT imaging with 152 Tb-labeled targeting agents has promise for clinical application and may be particularly interesting for pre-therapeutic dosimetry.
ERIC Educational Resources Information Center
Lark, Adam; Kramp, Robyne; Nurnberger-Haag, Julie
2008-01-01
Many teachers and students have experienced the classic pet rock experiment in conjunction with a geology unit. A teacher has students bring in a "pet" rock found outside of school, and the students run geologic tests on the rock. The tests include determining relative hardness using Mohs scale, checking for magnetization, and assessing luster.…
Wang, Hongkai; Zhou, Zongwei; Li, Yingci; Chen, Zhonghua; Lu, Peiou; Wang, Wenzhi; Liu, Wanyu; Yu, Lijuan
2017-12-01
This study aimed to compare one state-of-the-art deep learning method and four classical machine learning methods for classifying mediastinal lymph node metastasis of non-small cell lung cancer (NSCLC) from 18 F-FDG PET/CT images. Another objective was to compare the discriminative power of the recently popular PET/CT texture features with the widely used diagnostic features such as tumor size, CT value, SUV, image contrast, and intensity standard deviation. The four classical machine learning methods included random forests, support vector machines, adaptive boosting, and artificial neural network. The deep learning method was the convolutional neural networks (CNN). The five methods were evaluated using 1397 lymph nodes collected from PET/CT images of 168 patients, with corresponding pathology analysis results as gold standard. The comparison was conducted using 10 times 10-fold cross-validation based on the criterion of sensitivity, specificity, accuracy (ACC), and area under the ROC curve (AUC). For each classical method, different input features were compared to select the optimal feature set. Based on the optimal feature set, the classical methods were compared with CNN, as well as with human doctors from our institute. For the classical methods, the diagnostic features resulted in 81~85% ACC and 0.87~0.92 AUC, which were significantly higher than the results of texture features. CNN's sensitivity, specificity, ACC, and AUC were 84, 88, 86, and 0.91, respectively. There was no significant difference between the results of CNN and the best classical method. The sensitivity, specificity, and ACC of human doctors were 73, 90, and 82, respectively. All the five machine learning methods had higher sensitivities but lower specificities than human doctors. The present study shows that the performance of CNN is not significantly different from the best classical methods and human doctors for classifying mediastinal lymph node metastasis of NSCLC from PET/CT images. Because CNN does not need tumor segmentation or feature calculation, it is more convenient and more objective than the classical methods. However, CNN does not make use of the import diagnostic features, which have been proved more discriminative than the texture features for classifying small-sized lymph nodes. Therefore, incorporating the diagnostic features into CNN is a promising direction for future research.
Current application and future perspectives of PSMA PET imaging in prostate cancer.
Ceci, Francesco; Castellucci, Paolo; Fanti, Stefano
2018-03-08
As precision medicine evolves, the contribution of molecular imaging to the management of prostate cancer (PCa) patients, especially for Positron Emission Tomography (PET) imaging, is gaining importance. Highly successful approaches to measure the expression of the prostate specific membrane antigen (PSMA) have been introduced recently. PSMA, the glutamate carboxypeptidase II (GCP-II), is a membrane bound metallo-peptidase that is overexpressed in 90-100% of PCa cells. Due to its selective over-expression, PSMA is a reliable tissue marker for prostate cancer and is considered an ideal target for tumor specific imaging and therapy. A variety of PET and SPECT probes targeting this peptide receptor have been introduced. These are undergoing extensive clinical evaluations. Initial results attest to a high accuracy for disease detection compared conventional radiology (CT or MRI) and other nuclear medicine procedure (choline PET or fluciclovine PET). However, prospective evaluation of the impact on patient management for PSMA-ligand PET and its impact on patient outcome is currently missing. Finally, PSMA inhibitors can be radio-labeled with diagnostic (68Ga-PSMA-11), or therapeutic nuclides (177Lu/225Ac PSMA-617) to be used as theranostic agent. Initial results showed that PSMA-targeted radioligand therapy (RLT) can potentially delay disease progression in metastatic castrate-resistant PCa. This review aims to explore the current application of PSMA based imaging in prostate cancer, reporting about main advantages and limitations of this new theranostic procedure. The future perspectives and potential the applications of this agent will be also discussed.
NASA Astrophysics Data System (ADS)
Vatsadze, S. Z.; Eremina, O. E.; Veselova, I. A.; Kalmykov, S. N.; Nenajdenko, V. G.
2018-04-01
The pathogenesis of many socially significant diseases such as neurodegenerative dementias and neuroendocrine tumours involves imbalance of neurotransmitters. Among the known neuroimaging methods, positron emission tomography (PET) is the most perfect and informative technique for diagnosing these diseases. The potential of PET is largely determined by the inventory of available radiopharmaceuticals, that is, biologically active molecules containing short-lived nuclides with positron decay. This review gives a systematic account of the application of fluorine-18-labelled catecholamine type radiopharmaceuticals in clinical investigations of the sympathetic and central nervous systems. The methods for the synthesis of these agents and existing problems are considered. The material is arranged according to the mechanisms of reactions that underlie the synthetic approaches: electrophilic, nucleophilic and metal-catalyzed reactions. The bibliography includes 198 references.
Comparison of TOF-PET and Bremsstrahlung SPECT Images of Yttrium-90: A Monte Carlo Simulation Study.
Takahashi, Akihiko; Himuro, Kazuhiko; Baba, Shingo; Yamashita, Yasuo; Sasaki, Masayuki
2018-01-01
Yttrium-90 ( 90 Y) is a beta particle nuclide used in targeted radionuclide therapy which is available to both single-photon emission computed tomography (SPECT) and time-of-flight (TOF) positron emission tomography (PET) imaging. The purpose of this study was to assess the image quality of PET and Bremsstrahlung SPECT by simulating PET and SPECT images of 90 Y using Monte Carlo simulation codes under the same conditions and to compare them. In-house Monte Carlo codes, MCEP-PET and MCEP-SPECT, were employed to simulate images. The phantom was a torso-shaped phantom containing six hot spheres of various sizes. The background concentrations of 90 Y were set to 50, 100, 150, and 200 kBq/mL, and the concentrations of the hot spheres were 10, 20, and 40 times of those of the background concentrations. The acquisition time was set to 30 min, and the simulated sinogram data were reconstructed using the ordered subset expectation maximization method. The contrast recovery coefficient (CRC) and contrast-to-noise ratio (CNR) were employed to evaluate the image qualities. The CRC values of SPECT images were less than 40%, while those of PET images were more than 40% when the hot sphere was larger than 20 mm in diameter. The CNR values of PET images of hot spheres of diameter smaller than 20 mm were larger than those of SPECT images. The CNR values mostly exceeded 4, which is a criterion to evaluate the discernibility of hot areas. In the case of SPECT, hot spheres of diameter smaller than 20 mm were not discernable. On the contrary, the CNR values of PET images decreased to the level of SPECT, in the case of low concentration. In almost all the cases examined in this investigation, the quantitative indexes of TOF-PET 90 Y images were better than those of Bremsstrahlung SPECT images. However, the superiority of PET image became critical in the case of low activity concentrations.
Cross-Over Between Different Symmetries
NASA Astrophysics Data System (ADS)
Frauendorf, S.
2014-09-01
The yrast states of even even vibrational and transitional nuclei are interpreted as a rotating condensate of interacting d-bosons. The corresponding semi-classical tidal wave concept is used for microscopic calculations of energies and E2 transition probabilities. The strong octupole correlations in the light rare earth and actinide nuclides are interpreted as rotation-induced condensation of interacting f-bosons.
[(18)F-FDG PET/CT in the evaluation of patients suspected of paraneoplastic neurological syndrome].
García Vicente, A M; Vega Caicedo, C H; Mondéjar Solís, R; de Ayala Fernández, J Á; Garrido Robles, J A; Pena Pardo, F J; Muñoz Pasadas, M; Del Saz Saucedo, P; Jiménez Londoño, G A; León Martín, A; Soriano Castrejón, Á
2015-01-01
This study aimed to determine the diagnostic impact of (18)F-FDG PET/CT based on the clinical features of paraneoplastic neurological syndrome (PNS). Multicenter retrospective and longitudinal study of patients with suspicion of PNS. The clinical picture was classified into classic (CS) and non-classic syndrome (NCS). After the follow-up, the definitive or possible diagnosis of PNS was established. The pictures that did not match any of the previous criteria were categorized as non-classifiable. The state of the onco-neural antibodies was studied. The PET/CT was classified as positive or negative for the detection of malignancy. The relationship between PET/CT findings and the final diagnosis was determined. The differences between variables (Pearson test X(2)) and the relationship between the results of the PET/CT and the final diagnosis were analyzed. A total of 64 patients were analyzed, classifying 30% as CS and 42% as NCS. After the follow-up, 20% and 16% of subjects were diagnosed as possible and definitive PNS, respectively. Positive onco-neural antibodies were found in 13% of the patients. A definitive diagnosis of PNS was associated with a positive PET/CT (P=.08). A significant relation between antibodies expression and final diagnosis of neoplasia (P=.04) was demonstrated. The PET/CT correctly localized malignancy in 5/7 cases of invasive cancer. The PET/CT showed a higher percentage of positive results in patients with definitive diagnosis of PNS. Despite the low prevalence of malignancy in our series, the PET/CT detected malignancy in a significant proportion of patients with invasive cancer. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
Zhu, H; Wang, F; Guo, X Y; Li, L Q; Duan, D B; Liu, Z B; Yang, Z
2018-04-18
To provide useful information for the further production and application of this novel radio-nuclide for potential clinical application. 124 Te (p,n) 124 I nuclide reaction was used for the 124 I production. Firstly, the target material, 124 TeO 2 (200 mg) and Al2O3 (30 mg) mixture, were compressed into the round platinum based solid target by tablet device. HM-20 medical cyclotron was applied to irradiate the solid target slice for 6-10 h with helium and water cooling. Then, the radiated solid target was placed for 12 h (overnight) to decay the radioactive impurity; finally, 124 I was be purified by dry distillation using 1 mL/min nitrogen for about 6 hours and radiochemical separation methods. Micro-PET imaging studies were performed to investigate the metabolism properties and thyroid imaging ability of 124 I.After 740 kBq 124 I was injected intravenously into the tail vein of the normal mice, the animals were imaged with micro-PET and infused with CT. The micro-PET/CT infusion imaging revealed actual state 124 I's metabolism in the mice. It was been successfully applied for 200 mg 124 TeO 2 plating by the tablet device on the surface of platinum. It showed smooth, dense surface and without obviously pits and cracks. The enriched 124 Te target was irradiated for 6 to 10 hours at about 12.0 MeV with 20 μA current on HM-20 cyclotron. Then 370-1 110 MBq 124 I could be produced on the solid target after irradiation and 370-740 MBq high specific activity could be collected afterdry distillation separation and radio-chemical purification. 124 I product was finally dissolved in 0.01 mol/L NaOH for the future distribution. The gamma spectrum of the produced 124 I-solution showed that radionuclide purity was over 80.0%. The micro-PET imaging of 124 I in the normal mice exhibited the thyroid and stomach accumulations and kidney metabolism, the bladder could also be clearly visible, which was in accordance with what was previously reported. To the best of our knowledge, it was the first production of 124 I report in China. In this study, the preparation of 124 TeO 2 solid target was successfully carried out by using the tablet device. After irradiation of the 124 TeO 2 solid target and radio-chemical purification, we successfully produced 370-740 MBq high specific activity 124 I by a cyclotron for biomedical application, and micro-PET imaging of 124 I in normal mice exhibited the thyroid accumulations. Also, slight uptake in stomach were also monitored with almost nonuptake in other organs in the micro-PET imaging. The production of 124 I is expected to provide a new solid target radionuclide for the scientific research and potential clinical application of our country.
SBML-PET: a Systems Biology Markup Language-based parameter estimation tool.
Zi, Zhike; Klipp, Edda
2006-11-01
The estimation of model parameters from experimental data remains a bottleneck for a major breakthrough in systems biology. We present a Systems Biology Markup Language (SBML) based Parameter Estimation Tool (SBML-PET). The tool is designed to enable parameter estimation for biological models including signaling pathways, gene regulation networks and metabolic pathways. SBML-PET supports import and export of the models in the SBML format. It can estimate the parameters by fitting a variety of experimental data from different experimental conditions. SBML-PET has a unique feature of supporting event definition in the SMBL model. SBML models can also be simulated in SBML-PET. Stochastic Ranking Evolution Strategy (SRES) is incorporated in SBML-PET for parameter estimation jobs. A classic ODE Solver called ODEPACK is used to solve the Ordinary Differential Equation (ODE) system. http://sysbio.molgen.mpg.de/SBML-PET/. The website also contains detailed documentation for SBML-PET.
do Carmo, S J C; Alves, V H P; Alves, F; Abrunhosa, A J
2017-10-31
Following our previous work on the production of radiometals, such as 64 Cu and 68 Ga, through the irradiation of liquid targets using a medical cyclotron, we describe in this paper a technique to produce 61 Cu through the irradiation of natural zinc using a liquid target. The proposed method is very cost-effective, as it avoids the use of expensive enriched material, and is fast, as a purified solution of 61 CuCl 2 is obtained in less than 30 min after the end of beam. Considering its moderate half-life of 3.33 h and favourable decay properties as a positron emitter, 61 Cu is a very attractive nuclide for the labelling of PET tracers for pre-clinical and clinical use with PET as well as to support the intense R&D programmes being carried out worldwide by taking advantage of the rich and versatile chemistry of copper.
Engler, Whitney J; Bain, Melissa
2017-07-15
OBJECTIVE To determine the effect of different types of classical music played during a veterinary visit on dog behavior and owner satisfaction. DESIGN Prospective randomized controlled study. ANIMALS 74 dogs examined at a veterinary teaching hospital. PROCEDURES Dogs examined for a wellness visit, presurgical health evaluation, or nonurgent illness were exposed to 1 of 3 treatments (modified classical music, the same music in its original format, and no music [control]) while in the examination room. Owners completed a standardized survey regarding the dog's behavior and their satisfaction with the visit. Clinicians completed a separate standardized survey regarding the dog's behavior. Information regarding monetary charges, procedures performed, diagnoses, and physiologic variables was obtained from the electronic medical record after the appointment. RESULTS Owners rated their dog's anxiety level in the waiting room greater than that in the examination room regardless of treatment. Mean anxiety and aggression scores of dogs during the physical examination as rated by owners were significantly greater than those assigned by clinicians. Visit satisfaction for owners exposed to original classical music was significantly greater than that for owners not exposed to music. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested placing a pet and its owner into an examination room instead of a waiting room immediately after clinic arrival may ameliorate pet anxiety during the veterinary visit. Playing classical music at a low volume can be a simple and cost-effective way to improve owner satisfaction with the veterinary visit. Further research is necessary to determine the effects of music on pet anxiety.
NASA Astrophysics Data System (ADS)
Nishimura, N.; Rauscher, T.; Hirschi, R.; Murphy, A. St J.; Cescutti, G.; Travaglio, C.
2018-03-01
Thermonuclear supernovae originating from the explosion of a white dwarf accreting mass from a companion star have been suggested as a site for the production of p nuclides. Such nuclei are produced during the explosion, in layers enriched with seed nuclei coming from prior strong s processing. These seeds are transformed into proton-richer isotopes mainly by photodisintegration reactions. Several thousand trajectories from a 2D explosion model were used in a Monte Carlo approach. Temperature-dependent uncertainties were assigned individually to thousands of rates varied simultaneously in post-processing in an extended nuclear reaction network. The uncertainties in the final nuclear abundances originating from uncertainties in the astrophysical reaction rates were determined. In addition to the 35 classical p nuclides, abundance uncertainties were also determined for the radioactive nuclides 92Nb, 97, 98Tc, 146Sm, and for the abundance ratios Y(92Mo)/Y(94Mo), Y(92Nb)/Y(92Mo), Y(97Tc)/Y(98Ru), Y(98Tc)/Y(98Ru), and Y(146Sm)/Y(144Sm), important for Galactic Chemical Evolution studies. Uncertainties found were generally lower than a factor of 2, although most nucleosynthesis flows mainly involve predicted rates with larger uncertainties. The main contribution to the total uncertainties comes from a group of trajectories with high peak density originating from the interior of the exploding white dwarf. The distinction between low-density and high-density trajectories allows more general conclusions to be drawn, also applicable to other simulations of white dwarf explosions.
Notni, Johannes; Šimeček, Jakub; Wester, Hans-Jürgen
2014-06-01
Given the wide application of positron emission tomography (PET), positron-emitting metal radionuclides have received much attention recently. Of these, gallium-68 has become particularly popular, as it is the only PET nuclide commercially available from radionuclide generators, therefore allowing local production of PET radiotracers independent of an on-site cyclotron. Hence, interest in optimized bifunctional chelators for the elaboration of (68) Ga-labeled bioconjugates has been rekindled as well, resulting in the development of improved triazacyclononane-triphosphinate (TRAP) ligand structures. The most remarkable features of these ligands are unparalleled selectivity for Ga(III) , rapid Ga(III) complexation kinetics, extraordinarily high thermodynamic stability, and kinetic inertness of the respective Ga(III) chelates. As a result, TRAP chelators exhibit very favorable (68) Ga-labeling properties. Based on the scaffolds NOPO (1,4,7-triazacyclononane-1,4-bis[methylene(hydroxymethyl)phosphinic acid]-7-[methylene(2-carboxyethyl)phosphinic acid]) and TRAP-Pr, tailored for convenient preparation of (68) Ga-labeled monomeric and multimeric bioconjugates, a variety of novel (68) Ga radiopharmaceuticals have been synthesized. These include bisphosphonates, somatostatin receptor ligands, prostate-specific membrane antigen (PSMA)-targeting peptides, and cyclic RGD pentapeptides, for in vivo PET imaging of bone, neuroendocrine tumors, prostate cancer, and integrin expression, respectively. Furthermore, TRAP-based (68) Ga-labeled gadolinium(III) complexes have been proposed as bimodal probes for PET/MRI, and a cyclen-based analogue of TRAP-Pr has been suggested for the elaboration of targeted radiotherapeutics comprising radiolanthanide ions. Thus, polyazacycloalkane-based polyphosphinic acid chelators are a powerful toolbox for pharmaceutical research, particularly for the development of (68) Ga radiopharmaceuticals. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Meckel, M; Bergmann, R; Miederer, M; Roesch, F
2017-01-01
Bisphosphonates have a high adsorption on calcified tissues and are commonly used in the treatment of bone disorder diseases. Conjugates of bisphosphonates with macrocyclic chelators open new possibilities in bone targeted radionuclide imaging and therapy. Subsequent to positron emission tomography (PET) examinations utilizing 68 Ga-labelled analogues, endoradiotheraphy with 177 Lu-labelled macrocyclic bisphosphonates may have a great potential in the treatment of painful skeletal metastases. Based on the established pharmaceuticals pamidronate and zoledronate two new DOTA-α-OH-bisphosphonates, DOTA PAM and DOTA ZOL (MM1.MZ) were successfully synthesized. The ligands were labelled with the positron emitting nuclide 68 Ga and the β - emitting nuclide 177 Lu and compared in in vitro studies and in ex vivo biodistribution studies together with small animal PET and single photon emission computed tomography (SPECT) studies against [ 18 F]NaF and a known DOTA-α-H-bisphosphonate conjugate (BPAPD) in healthy Wistar rats. The new DOTA-bisphosphonates can be labelled in high yield of 80 to 95 % in 15 min with post-processed 68 Ga and >98 % with 177 Lu. The tracers showed very low uptake in soft tissue, a fast renal clearance and a high accumulation on bone. The best compound was [ 68 Ga]DOTA ZOL (SUV Femur = 5.4 ± 0.6) followed by [ 18 F]NaF (SUV Femur = 4.8 ± 0.2), [ 68 Ga]DOTA PAM (SUV Femur = 4.5 ± 0.2) and [ 68 Ga]BPAPD (SUV Femur = 3.2 ± 0.3). [ 177 Lu]DOTA ZOL showed a similar distribution as the diagnostic 68 Ga complex. The 68 Ga labelled compounds showed a promising pharmacokinetics, with similar uptake profile and distribution kinetics. Bone accumulation was highest for [ 68 Ga]DOTA ZOL , which makes this compound probably an interesting bone targeting agent for a therapeutic approach with 177 Lu. The therapeutic compound [ 177 Lu]DOTA ZOL showed a high target-to-background ratio. SPECT experiments showed concordance to the PET scans in healthy rats. [ 68 Ga/ 177 Lu]DOTA ZOL appears to be a potential theranostic combination in the management of disseminated bone metastases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milgrom, Sarah A., E-mail: samilgrom@mdanderson.org; Dong, Wenli; Akhtari, Mani
Purpose: In early-stage classical Hodgkin lymphoma, fluorodeoxyglucose positron emission tomography (PET)-computed tomography (CT) scans are performed routinely after chemotherapy, and the 5-point Deauville score is used to report the disease response. We hypothesized that other PET-CT parameters, considered in combination with Deauville score, would improve risk stratification. Methods and Materials: Patients treated for stage I to II Hodgkin lymphoma from 2003 to 2013, who were aged ≥18 years and had analyzable PET-CT scans performed before and after chemotherapy, were eligible. The soft tissue volume (STV), maximum standardized uptake value, metabolic tumor volume, and total lesion glycolysis were recorded from the PET-CTmore » scans before and after chemotherapy. Reductions were defined as 1 − (final PET-CT value)/(corresponding initial PET-CT value). The primary endpoint was freedom from progression (FFP). Results: For 202 patients treated with chemotherapy with or without radiation therapy, the 5-year FFP was 89% (95% confidence interval 85%-93%). All PET-CT parameters were strongly associated with the Deauville score (P<.001) and FFP (P<.0001) on univariate analysis. The Deauville score was highly predictive of FFP (C-index 0.89) but was less discriminating in the Deauville 1 to 4 subset (C-index 0.67). Therefore, we aimed to identify PET-CT parameters that would improve risk stratification for this subgroup (n=187). STV reduction was predictive of outcome (C-index 0.71) and was dichotomized with an optimal cutoff of 0.65 (65% reduction in STV). A model incorporating the Deauville score and STV reduction predicted FFP more accurately than either measurement alone in the Deauville 1 to 4 subset (C-index 0.83). The improvement in predictive accuracy of this composite measure compared with the Deauville score alone met statistical significance (P=.045). Conclusions: The relative reduction in tumor size is an independent predictor of outcome. Combined with the Deauville score, it might improve risk stratification and contribute to response-adapted individualization of therapy.« less
Notni, Johannes; Wester, Hans-Jürgen
2018-03-01
The potential and future role of certain metal radionuclides, for example, 44 Sc, 89 Zr, 86 Y, 64 Cu, 68 Ga, 177 Lu, 225 Ac, and 213 Bi, and several terbium isotopes has been controversially discussed in the past decades. Furthermore, the possible benefits of "matched pairs" of isotopes for tandem applications of diagnostics and therapeutics (theranostics) have been emphasized, while such approaches still have not made their way into routine clinical practice. Analysis of bibliographical data illustrates how popularity of certain nuclides has been promoted by cycles of availability and applications. We furthermore discuss the different practical requirements for diagnostic and therapeutic radiopharmaceuticals and the resulting consequences for efficient development of clinically useful pairs of radionuclide theranostics, with particular emphasis on the underlying economical factors. Based on an exemplary assessment of overall production costs for 68 Ga and 18 F radiopharmaceuticals, we venture a look into the future of theranostics and predict that high-throughput PET applications, that is, diagnosis of frequent conditions, will ultimately rely on 18 F tracers. PET radiometals will occupy a niche in the clinical low-throughput sector (diagnosis of rare diseases), but above all, dominate preclinical research and clinical translation. Matched isotope pairs will be of lesser relevance for theranostics but may become important for future PET-based therapeutic dosimetry. Copyright © 2017 John Wiley & Sons, Ltd.
Janelidze, Shorena; Pannee, Josef; Mikulskis, Alvydas; Chiao, Ping; Zetterberg, Henrik; Blennow, Kaj; Hansson, Oskar
2017-12-01
Visual assessment of amyloid positron emission tomographic (PET) images has been approved by regulatory authorities for clinical use. Several immunoassays have been developed to measure β-amyloid (Aβ) 42 in cerebrospinal fluid (CSF). The agreement between CSF Aβ42 measures from different immunoassays and visual PET readings may influence the use of CSF biomarkers and/or amyloid PET assessment in clinical practice and trials. To determine the concordance between CSF Aβ42 levels measured using 5 different immunoassays and visual amyloid PET analysis. The study included 262 patients with mild cognitive impairment or subjective cognitive decline from the Swedish BioFINDER (Biomarkers for Identifying Neurodegenerative Disorders Early and Reliably) cohort (recruited from September 1, 2010, through December 31, 2014) who had undergone flutemetamol F 18 ([18F]flutemetamol)-labeled PET. Levels of CSF Aβ42 were analyzed using the classic INNOTEST and the newer modified INNOTEST, fully automated Lumipulse (FL), EUROIMMUN (EI), and Meso Scale Discovery (MSD) assays. Concentrations of CSF Aβ were assessed using an antibody-independent mass spectrometry-based reference measurement procedure. The concordance of CSF Aβ42 levels and Aβ42:Aβ40 and Aβ42:tau ratios with visual [18F]flutemetamol PET status. Of 262 participants (mean [SD] age, 70.9 [5.5] years), 108 were women (41.2%) and 154 were men (58.8%). The mass spectrometry-derived Aβ42 values showed higher correlations with the modified Aβ42-INNOTEST (r = 0.97), Aβ42-FL (r = 0.93), Aβ42-EI (r = 0.93), and Aβ42-MSD (r = 0.95) assays compared with the classic Aβ42-INNOTEST assay (r = 0.88; P ≤ .01). The signal in the classic Aβ42-INNOTEST assay was partly quenched by recombinant Aβ1-40 peptide. However, the classic Aβ42-INNOTEST assay showed better concordance with visual [18F]flutemetamol PET status (area under the receiver operating characteristic curve [AUC], 0.92) compared with the newer assays (AUCs, 0.87-0.89; P ≤ .01). The accuracies of the newer assays improved significantly when Aβ42:Aβ40 (AUCs, 0.93-0.95; P ≤ .01), Aβ42 to total tau (T-tau) (AUCs, 0.94; P ≤ .05), or Aβ42 to phosphorylated tau (P-tau) (AUCs, 0.94-0.95; P ≤ .001) ratios were used. A combination of the Aβ42:Aβ40 ratio and T-tau or P-tau level did not improve the accuracy compared with the ratio alone. Concentrations of CSF Aβ42 derived from the new immunoassays (modified INNOTEST, FL, EI, and MSD) may correlate better with the antibody-independent mass spectrometry-based reference measurement procedure and may show improved agreement with visual [18F]flutemetamol PET assessment when using the Aβ42:Aβ40 or Aβ42:tau ratios. These findings suggest the benefit of implementing the CSF Aβ42:Aβ40 or Aβ42:tau ratios as a biomarker of amyloid deposition in clinical practice and trials.
Similarities between obesity in pets and children: the addiction model.
Pretlow, Robert A; Corbee, Ronald J
2016-09-01
Obesity in pets is a frustrating, major health problem. Obesity in human children is similar. Prevailing theories accounting for the rising obesity rates - for example, poor nutrition and sedentary activity - are being challenged. Obesity interventions in both pets and children have produced modest short-term but poor long-term results. New strategies are needed. A novel theory posits that obesity in pets and children is due to 'treats' and excessive meal amounts given by the 'pet-parent' and child-parent to obtain affection from the pet/child, which enables 'eating addiction' in the pet/child and results in parental 'co-dependence'. Pet-parents and child-parents may even become hostage to the treats/food to avoid the ire of the pet/child. Eating addiction in the pet/child also may be brought about by emotional factors such as stress, independent of parental co-dependence. An applicable treatment for child obesity has been trialled using classic addiction withdrawal/abstinence techniques, as well as behavioural addiction methods, with significant results. Both the child and the parent progress through withdrawal from specific 'problem foods', next from snacking (non-specific foods) and finally from excessive portions at meals (gradual reductions). This approach should adapt well for pets and pet-parents. Pet obesity is more 'pure' than child obesity, in that contributing factors and treatment points are essentially under the control of the pet-parent. Pet obesity might thus serve as an ideal test bed for the treatment and prevention of child obesity, with focus primarily on parental behaviours. Sharing information between the fields of pet and child obesity would be mutually beneficial.
NASA Astrophysics Data System (ADS)
Alfuraih, Abdulrahman; Alzimami, Khalid; Ma, Andy K.; Alghamdi, Ali; Al Jammaz, Ibrahim
2014-11-01
Immuno-PET is a nuclear medicine technique that combines positron emission tommography (PET) with radio-labeled monoclonal antibodies (mAbs) for tumor characterization and therapy. Zirconium-89 (89Zr) is an emerging radionuclide for immuno-PET imaging. Its long half-life (78.4 h) gives ample time for the production, the administering and the patient uptake of the tagged radiopharmaceutical. Furthermore, the nuclides will remain in the tumor cells after the mAbs are catabolized so that time series studies are possible without incurring further administration of radiopharmarceuticals. 89Zr can be produced in medical cyclotrons by bombarding an yttrium-89 (89Y) target with a proton beam through the 89Y(p,n)89Zr reaction. In this study, we estimated the effective dose to the head and neck cancer patients undergoing 89Zr-based immune-PET procedures. The production of 89Zr and the impurities from proton irradiation of the 89Y target in a cyclotron was calculated with the Monte Carlo code MCNPX and the nuclear reaction code TALYS. The cumulated activities of the Zr isotopes were derived from real patient data in literature and the effective doses were estimated using the MIRD specific absorbed fraction formalism. The estimated effective dose from 89Zr is 0.5±0.2 mSv/MBq. The highest organ dose is 1.8±0.2 mSv/MBq in the liver. These values are in agreement with those reported in literature. The effective dose from 89mZr is about 0.2-0.3% of the 89Zr dose in the worst case. Since the ratio of 89mZr to 89Zr depends on the cooling time as well as the irradiation details, contaminant dose estimation is an important aspect in optimizing the cyclotron irradiation geometry, energy and time.
A Pretargeted Approach for the Multimodal PET/NIRF Imaging of Colorectal Cancer.
Adumeau, Pierre; Carnazza, Kathryn E; Brand, Christian; Carlin, Sean D; Reiner, Thomas; Agnew, Brian J; Lewis, Jason S; Zeglis, Brian M
2016-01-01
The complementary nature of positron emission tomography (PET) and near-infrared fluorescence (NIRF) imaging makes the development of strategies for the multimodal PET/NIRF imaging of cancer a very enticing prospect. Indeed, in the context of colorectal cancer, a single multimodal PET/NIRF imaging agent could be used to stage the disease, identify candidates for surgical intervention, and facilitate the image-guided resection of the disease. While antibodies have proven to be highly effective vectors for the delivery of radioisotopes and fluorophores to malignant tissues, the use of radioimmunoconjugates labeled with long-lived nuclides such as 89 Zr poses two important clinical complications: high radiation doses to the patient and the need for significant lag time between imaging and surgery. In vivo pretargeting strategies that decouple the targeting vector from the radioactivity at the time of injection have the potential to circumvent these issues by facilitating the use of positron-emitting radioisotopes with far shorter half-lives. Here, we report the synthesis, characterization, and in vivo validation of a pretargeted strategy for the multimodal PET and NIRF imaging of colorectal carcinoma. This approach is based on the rapid and bioorthogonal ligation between a trans -cyclooctene- and fluorophore-bearing immunoconjugate of the huA33 antibody (huA33-Dye800-TCO) and a 64 Cu-labeled tetrazine radioligand ( 64 Cu-Tz-SarAr). In vivo imaging experiments in mice bearing A33 antigen-expressing SW1222 colorectal cancer xenografts clearly demonstrate that this approach enables the non-invasive visualization of tumors and the image-guided resection of malignant tissue, all at only a fraction of the radiation dose created by a directly labeled radioimmunoconjugate. Additional in vivo experiments in peritoneal and patient-derived xenograft models of colorectal carcinoma reinforce the efficacy of this methodology and underscore its potential as an innovative and useful clinical tool.
New aspects of molecular imaging in prostate cancer.
Ceci, Francesco; Castellucci, Paolo; Cerci, Juliano J; Fanti, Stefano
2017-11-01
Nowadays several new imaging modalities are available for investigating prostate cancer (PCa) such as magnet resonance imaging (MRI) in the form of whole body MRI and pelvic multiparametric MRI and positron emission tomography (PET) using choline as radiotracers. Nevertheless, these modalities proved sub-optimal accuracy for detecting PCa metastases, particularly in the recurrence setting. A new molecular probe targeting the prostate specific membrane antigen (PSMA) has been recently developed for PET imaging. PSMA, the glutamate carboxypeptidase II, is a membrane bound metallo-peptidase over-expressed in PCa cells. It has been shown that PSMA based imaging offers higher tumor detection rate compared to choline PET/CT and radiological conventional imaging, especially at very low PSA levels during biochemical recurrence. In addition PSMA, as theranostics agent, allows both radiolabeling with diagnostic (e.g. 68Ga, 18F) or therapeutic nuclides (e.g. 177Lu, 225Ac). Initial results show that PSMA-targeted radioligand therapy can potentially delay disease progression in metastatic castrate-resistant PCa. Despite still investigational, the bombesin-based radiotracers and antagonist of gastrin releasing-peptide receptor (GRP) (RM2) and anti1-amino-3-18Ffluorocyclobutane-1-carboxylic acid (18F-FACBC) are emerging as possible alternatives for investigating PCa. Considering the wide diffusion of PCa in the Europe and the United States, the presence of these new diagnostic techniques able to detect the disease with high sensitivity and specificity might have a clinical impact on the management of patients. PET/CT imaging with new radiopharmaceuticals can implement the patient management identifying lesion(s) not detectable with conventional imaging procedures. In this review article will be discussed the most promising new PET radiopharmaceuticals (68Ga-PSMA-11, 18F-FACBC, 68Ga-RM2) available at the moment, focusing the attention on their accuracy and their impact on treatment strategy. Copyright © 2017 Elsevier Inc. All rights reserved.
Dollé, Frédéric
2013-01-01
Exploration of the living human brain in real-time and in a noninvasive way was for centuries only a dream, made, however, possible today with the remarkable development during the four last decades of powerful molecular imaging techniques, and especially positron emission tomography (PET). Molecular PET imaging relies, from a chemical point of view, on the use and preparation of a positron-emitting radiolabelled probe or radiotracer, notably compounds incorporating one of two short-lived radionuclides fluorine-18 (T1/2 : 109.8 min) and carbon-11 (T1/2 : 20.38 min). The growing availability and interest for the radiohalogen fluorine-18 in radiopharmaceutical chemistry undoubtedly results from its convenient half-life and the successful use in clinical oncology of 2-[(18) F]fluoro-2-deoxy-d-glucose ([(18) F]FDG). The special interest of carbon-11 is not only that carbon is present in virtually all biomolecules and drugs allowing therefore for isotopic labelling of their chemical structures but also that a given molecule could be radiolabelled at different functions or sites, permitting to explore (or to take advantage of) in vivo metabolic pathways. PET chemistry includes production of these short-lived radioactive isotopes via nuclear transmutation reactions using a cyclotron, and is directed towards the development of rapid synthetic methods, at the trace level, for the introduction of these nuclides into a molecule, as well as the use of fast purification, analysis and formulation techniques. PET chemistry is the driving force in molecular PET imaging, and this special issue of the Journal of Labelled Compounds and Radiopharmaceuticals, which is strongly chemistry and radiochemistry-oriented, aims at illustrating, be it in part only, the state-of-the-art arsenal of reactions currently available and its potential for the research and development of specific molecular probes labelled with the positron emitters carbon-11 and fluorine-18, with optimal imaging properties for PET exploration of the brain. Copyright © 2013 John Wiley & Sons, Ltd.
Two-proton pickup studies with the (6Li,8B) reaction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weisenmiller, R.B.
1976-12-03
The (/sup 6/Li,/sup 8/B) reaction has been investigated on targets of /sup 26/Mg, /sup 24/Mg, /sup 16/O, /sup 13/C, /sup 12/C, /sup 11/B, /sup 10/B, and /sup 9/Be at a bombarding energy of 80.0 MeV, and on targets of /sup 16/O, /sup 12/C, /sup 9/Be, /sup 7/Li, and /sup 6/Li at a bombarding energy of 93.3 MeV. Only levels consistent with direct, single-step two-proton pickup reaction mechanisms were observed to be strongly populated. On T/sub z/ = 0 targets, the spectroscopic selectivity of this reaction resembles that of the analogous (p,t) reaction. Additionally, these data demonstrate the dominance of spatiallymore » symmetric transfer of the two protons. On T/sub z/ greater than 0 targets the (/sup 6/Li,/sup 8/B) reaction was employed to locate two previously unreported levels (at 7.47 +- 0.05 MeV and 8.86 +- 0.07 MeV) in the T/sub z/ = 2 nuclide /sup 24/Ne and to establish the low-lying 1p-shell states in the T/sub z/ = /sup 3///sub 2/ nuclei /sup 11/Be, /sup 9/Li, and /sup 7/He. However, no evidence was seen for any narrow levels in the T/sub z/ = /sup 3///sub 2/ nuclide /sup 5/H nor for any narrow excited states in /sup 7/He. The angular distributions reported here are rather featureless and decrease monotonically with increasing angle. This behavior can be shown by a semi-classical reaction theory to be a consequence of the reaction kinematics. A semi-classical approach also suggests that the kinematic term in the transition matrix element is only weakly dependent upon the angular momentum transfer (which is consistent with simple Distorted Wave Born Approximation calculations). However, only qualitative agreement was obtained between the observed relative transition yields and semi-classical predictions, using the two-nucleon coefficients of fractional parentage of Cohen and Kurath, probably due to the limitations of the semi-classical reaction theory.« less
Engineering refinements to overcome default nuclide regulatory constraints
NASA Astrophysics Data System (ADS)
Finn, R.; Capitelli, P.; Sheh, Y.; Lom, C.; Graham, M.; Germain, J. St.
2005-12-01
The "classical" positron emitting radionuclides include oxygen-15, nitrogen-13 and carbon-11 which possess unique properties for medical imaging. They are radionuclides of the fundamental elements of biological matter. They each possess short half-lives which allow their use in designed radiotracers for clinical investigations with minimal risk and they are readily able to be produced in sufficient activities by low energy nuclear reactions. At present several accelerator manufacturers offer production packages for these radionuclides emphasizing targetry with consideration of the cyclotron extracted energies for nuclide production and on-line chemistry systems for the continuous production of specific precursors or radiotracers. Following the installation and acceptance of the MSKCC TR 19/9 Cyclotron, our experience with the procured chemistry module for the preparation of oxygen-15 labeled water has forced us to examine the design and the operation of the synthetic unit with a view toward the state of New York's regulations addressing the environmental pollution from radioactive materials. The chemistry module was refined with subtle modifications to the chemistry procedure/unit and our experience with the unit is presented as an example of our approach to insure regulatory compliance.
NASA Astrophysics Data System (ADS)
Fratila, Raluca M.; Gomez, M. Victoria; Sýkora, Stanislav; Velders, Aldrik H.
2014-01-01
Nuclear magnetic resonance (NMR) spectroscopy is a powerful analytical technique, but its low sensitivity and highly sophisticated, costly, equipment severely constrain more widespread applications. Here we show that a non-resonant planar transceiver microcoil integrated in a microfluidic chip (detection volume 25 nl) can detect different nuclides in the full broad-band range of Larmor frequencies (at 9.4 T from 61 to 400 MHz). Routine one-dimensional (1D) and two-dimensional (2D), homo- and heteronuclear experiments can be carried out using the broad-band coil set-up. Noteworthy, heteronuclear 2D experiments can be performed in a straightforward manner on virtually any combination of nuclides (from classical 1H-13C to more exotic combinations like 19F-31P) both in coupled and decoupled mode. Importantly, the concept of a non-resonant system provides magnetic field-independent NMR probes; moreover, the small-volume alleviates problems related to field inhomogeneity, making the broad-band coil an attractive option for, for example, portable and table-top NMR systems.
Orthogonal strip HPGe planar SmartPET detectors in Compton configuration
NASA Astrophysics Data System (ADS)
Boston, H. C.; Gillam, J.; Boston, A. J.; Cooper, R. J.; Cresswell, J.; Grint, A. N.; Mather, A. R.; Nolan, P. J.; Scraggs, D. P.; Turk, G.; Hall, C. J.; Lazarus, I.; Berry, A.; Beveridge, T.; Lewis, R.
2007-10-01
The evolution of Germanium detector technology over the last decade has lead to the possibility that they can be employed in medical and security imaging. The potential of excellent energy resolution coupled with good position information that Germanium affords removes the necessity for mechanical collimators that would be required in a conventional gamma camera system. By removing this constraint, the overall dose to the patient can be reduced or the throughput of the system can be increased. An additional benefit of excellent energy resolution is that tight gates can be placed on energies from either a multi-lined gamma source or from multi-nuclide sources increasing the number of sources that can be used in medical imaging. In terms of security imaging, segmented Germanium gives directionality and excellent spectroscopic information.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Enghauser, Michael
2016-02-01
The goal of the Domestic Nuclear Detection Office (DNDO) Algorithm Improvement Program (AIP) is to facilitate gamma-radiation detector nuclide identification algorithm development, improvement, and validation. Accordingly, scoring criteria have been developed to objectively assess the performance of nuclide identification algorithms. In addition, a Microsoft Excel spreadsheet application for automated nuclide identification scoring has been developed. This report provides an overview of the equations, nuclide weighting factors, nuclide equivalencies, and configuration weighting factors used by the application for scoring nuclide identification algorithm performance. Furthermore, this report presents a general overview of the nuclide identification algorithm scoring application including illustrative examples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Enghauser, Michael
2015-02-01
The goal of the Domestic Nuclear Detection Office (DNDO) Algorithm Improvement Program (AIP) is to facilitate gamma-radiation detector nuclide identification algorithm development, improvement, and validation. Accordingly, scoring criteria have been developed to objectively assess the performance of nuclide identification algorithms. In addition, a Microsoft Excel spreadsheet application for automated nuclide identification scoring has been developed. This report provides an overview of the equations, nuclide weighting factors, nuclide equivalencies, and configuration weighting factors used by the application for scoring nuclide identification algorithm performance. Furthermore, this report presents a general overview of the nuclide identification algorithm scoring application including illustrative examples.
NASA Astrophysics Data System (ADS)
Chabaux, F.; Blaes, E.; Stille, P.; di Chiara Roupert, R.; Pelt, E.; Dosseto, A.; Ma, L.; Buss, H. L.; Brantley, S. L.
2013-01-01
A 2 m-thick spheroidal weathering profile, developed on a quartz diorite in the Rio Icacos watershed (Luquillo Mountains, eastern Puerto Rico), was analyzed for major and trace element concentrations, Sr and Nd isotopic ratios and U-series nuclides (238U-234U-230Th-226Ra). In this profile a 40 cm thick soil horizon is overlying a 150 cm thick saprolite which is separated from the basal corestone by a ˜40 cm thick rindlet zone. The Sr and Nd isotopic variations along the whole profile imply that, in addition to geochemical fractionations associated to water-rock interactions, the geochemical budget of the profile is influenced by a significant accretion of atmospheric dusts. The mineralogical and geochemical variations along the profile also confirm that the weathering front does not progress continuously from the top to the base of the profile. The upper part of the profile is probably associated with a different weathering system (lateral weathering of upper corestones) than the lower part, which consists of the basal corestone, the associated rindlet system and the saprolite in contact with these rindlets. Consequently, the determination of weathering rates from 238U-234U-230Th-226Ra disequilibrium in a series of samples collected along a vertical depth profile can only be attempted for samples collected in the lower part of the profile, i.e. the rindlet zone and the lower saprolite. Similar propagation rates were derived for the rindlet system and the saprolite by using classical models involving loss and gain processes for all nuclides to interpret the variation of U-series nuclides in the rindlet-saprolite subsystem. The consistency of these weathering rates with average weathering and erosion rates derived via other methods for the whole watershed provides a new and independent argument that, in the Rio Icacos watershed, the weathering system has reached a geomorphologic steady-state. Our study also indicates that even in environments with differential weathering, such as observed for the Puerto Rico site, the radioactive disequilibrium between the nuclides of a single radioactive series (here 238U-234U-230Th-226Ra) can still be interpreted in terms of a simplified scenario of congruent weathering. Incidentally, the U-Th-Ra disequilibrium in the corestone samples confirms that the outermost part of the corestone is already weathered.
Subcortical aphasia: a longitudinal PET study.
de Boissezon, Xavier; Démonet, Jean-François; Puel, Michèle; Marie, Nathalie; Raboyeau, Gaëlle; Albucher, Jean-François; Chollet, François; Cardebat, Dominique
2005-07-01
Very few neuroimaging studies have focused on follow-up of subcortical aphasia. Here, overt language production tasks were used to correlate regional cerebral blood flow (rCBF) changes and language performance in patients with vascular subcortical lesions. Seven aphasic patients were scanned twice with positron emission tomography (PET) at 1-year interval during a word-generation task. Using SPM2, Language-Rest contrast at PET1 was correlated to language performance and to time-lag from stroke. The same contrast was performed at PET2 and session effect (PET2-PET1) was correlated with performance improvement. At PET1, correlation between rCBF and delay from stroke involved mainly ventral regions of the left temporal cortex and mesial frontal cortex. Correlations between rCBF and performance showed predominantly left dorsal regions in the frontal, temporal, and parietal lobes, but also the left ventral temporal cortex. One year apart, language performance improved and rCBF increased in perisylvian regions bilaterally. Best performers at PET2 showed an increase of activity in left ventral temporal cortex as well as in right middle temporal gyrus. On follow-up, expected language improvement and increase of activation in the classical language areas and their counterparts were observed. Moreover, all correlational analyses both at PET1 and on follow-up implicated the anterior part of the left inferior temporal gyrus, suggesting a disconnection between the superior and inferior parts of the left temporal cortex and a specific role for this region in lexical semantic processing.
Nuclide Guide and International Chart of Nuclides - 2008
NASA Astrophysics Data System (ADS)
Golashvili, T.
2009-08-01
New versions of Nuclide Guide and Chart of the Nuclides were developed as a result of Russian-Chinese collaboration. The Nuclide Guide contains the basic information on more than 3000 radioactive and stable nuclides. The characteristics of isomers with half-lives more than 1 ms are included. For each nuclide spin, parity, mass of nuclide, magnetic moment (if available), mass excess, half-life or abundance, decay modes, branching ratios, emitted particles, energies of most intense gamma-rays and their intensities, decay energies and mean values of radiation energy per decay are given. For stable and natural long-lived nuclides cross-sections of thermal neutron induced activation are indicated. The information presented in the Guide was compiled from 5 sources: 1) ENSDF-2008, 2) atomic mass evaluation-2005 by Audi and Wapstra, 3) interactive data bases at web-sites
NASA Astrophysics Data System (ADS)
Newell, S. D.; Hodell, D. A.; Curtis, J. H.; Brenner, M.; Venz-Curtis, K.
2005-12-01
The Petén region of northern Guatemala has been occupied by humans for more than 3000 years. Expansion of the Maya civilization during the Preclassic (~1000 BC to AD 250) and Classic (AD 250 to AD 900) Periods was accompanied by increasing deforestation of Petén watersheds and accelerated rates of soil erosion. Palynological data from Petén lake cores illustrate the near elimination of high forest taxa and prevalence of disturbance taxa (grasses, weeds) during the height of Classic Maya occupation (~AD 500 to AD 800). After flourishing during the Classic Period between AD 250 and 800, Maya population densities declined significantly in the Petén, thereby curtailing human pressures on the landscape. This cycle of population expansion and decline in the Petén provides a natural historical experiment that has been used to study the response of tropical vegetation to long-term changes in land-use by humans. We measured the carbon isotopic composition of long-chain n-alkanes of leaf waxes in two cores from Lakes Sacnab and Salpetén in the Petén Lake District of the southern Maya Lowlands. The carbon isotopic composition of leaf waxes has been shown to be a reliable indicator of the relative proportion of C3 to C4 biomass in a watershed. Biomarker results were compared directly to a pollen profile from Lake Salpetén. Although the general pattern of increased C4 abundance inferred from δ13C of long-chain n-alkanes and increased disturbance taxa from pollen studies agree during the period of Maya occupation, the two proxies differ in detail suggesting they are recording different characteristics of watershed vegetation. For example, the highest long-chain δ13C values (representing greatest C4 biomass) occurred during early settlement of the basins in the early to middle Preclassic Period (1300 to 500 BC) when Maya population densities were relatively low. This period also corresponded to the time of greatest erosion rates in the Salpetén basin (Anselmetti et al., in prep.). In contrast, pollen profiles indicate the highest percentages of disturbance taxa and lowest high forest taxa from 250 BC to AD 700 in the late Preclassic and Classic Periods, when both the δ13C of long-chain n-alkanes and erosion rates declined. The high compound-specific δ13C values in the early to middle Preclassic Period may be greatly influenced by the early cultivation of maize (a C4 plant) along the shoreline. In contrast, maize is generally under-represented in pollen profiles because of its large size and difficulty of transport. Pollen may be more representative of vegetation over a larger area than the lipid biomarkers, but is biased towards tropical vegetation that is pollinated by wind and does not reflect those plants that depend on pollination by insects or self-fertilization. The δ13C of long-chain n-alkanes, on the other hand, may provide a reliable proxy for estimating the relative changes in C3 to C4 biomass, but it cannot be used to interpret changes in forest structure and composition. We conclude that the δ13C of long-chain n-alkanes and pollen are recording different aspects of watershed vegetation in Petén, and should be used in tandem to infer the response of tropical vegetation to past changes in Maya land-use.
NASA Astrophysics Data System (ADS)
Janek Strååt, Sara; Andreassen, Björn; Jonsson, Cathrine; Noz, Marilyn E.; Maguire, Gerald Q., Jr.; Näfstadius, Peder; Näslund, Ingemar; Schoenahl, Frederic; Brahme, Anders
2013-08-01
The purpose of this study was to investigate in vivo verification of radiation treatment with high energy photon beams using PET/CT to image the induced positron activity. The measurements of the positron activation induced in a preoperative rectal cancer patient and a prostate cancer patient following 50 MV photon treatments are presented. A total dose of 5 and 8 Gy, respectively, were delivered to the tumors. Imaging was performed with a 64-slice PET/CT scanner for 30 min, starting 7 min after the end of the treatment. The CT volume from the PET/CT and the treatment planning CT were coregistered by matching anatomical reference points in the patient. The treatment delivery was imaged in vivo based on the distribution of the induced positron emitters produced by photonuclear reactions in tissue mapped on to the associated dose distribution of the treatment plan. The results showed that spatial distribution of induced activity in both patients agreed well with the delivered beam portals of the treatment plans in the entrance subcutaneous fat regions but less so in blood and oxygen rich soft tissues. For the preoperative rectal cancer patient however, a 2 ± (0.5) cm misalignment was observed in the cranial-caudal direction of the patient between the induced activity distribution and treatment plan, indicating a beam patient setup error. No misalignment of this kind was seen in the prostate cancer patient. However, due to a fast patient setup error in the PET/CT scanner a slight mis-position of the patient in the PET/CT was observed in all three planes, resulting in a deformed activity distribution compared to the treatment plan. The present study indicates that the induced positron emitters by high energy photon beams can be measured quite accurately using PET imaging of subcutaneous fat to allow portal verification of the delivered treatment beams. Measurement of the induced activity in the patient 7 min after receiving 5 Gy involved count rates which were about 20 times lower than that of a patient undergoing standard 18F-FDG treatment. When using a combination of short lived nuclides such as 15O (half-life: 2 min) and 11C (half-life: 20 min) with low activity it is not optimal to use clinical reconstruction protocols. Thus, it might be desirable to further optimize reconstruction parameters as well as to address hardware improvements in realizing in vivo treatment verification with PET/CT in the future. A significant improvement with regard to 15O imaging could also be expected by having the PET/CT unit located close to the radiation treatment room.
Shielding and activity estimator for template-based nuclide identification methods
Nelson, Karl Einar
2013-04-09
According to one embodiment, a method for estimating an activity of one or more radio-nuclides includes receiving one or more templates, the one or more templates corresponding to one or more radio-nuclides which contribute to a probable solution, receiving one or more weighting factors, each weighting factor representing a contribution of one radio-nuclide to the probable solution, computing an effective areal density for each of the one more radio-nuclides, computing an effective atomic number (Z) for each of the one more radio-nuclides, computing an effective metric for each of the one or more radio-nuclides, and computing an estimated activity for each of the one or more radio-nuclides. In other embodiments, computer program products, systems, and other methods are presented for estimating an activity of one or more radio-nuclides.
Workshop on Cosmogenic Nuclides
NASA Technical Reports Server (NTRS)
Reedy, R. C. (Editor); Englert, P. (Editor)
1986-01-01
Abstracts of papers presented at the Workshop on Cosmogenic Nuclides are compiled. The major topic areas covered include: new techniques for measuring nuclides such as tandem accelerator and resonance mass spectrometry; solar modulation of cosmic rays; pre-irradiation histories of extraterrestrial materials; terrestrial studies; simulations and cross sections; nuclide production rate calculations; and meteoritic nuclides.
Assessing Food Preferences in Dogs and Cats: A Review of the Current Methods.
Tobie, Christelle; Péron, Franck; Larose, Claire
2015-03-18
Food is a major aspect of pet care; therefore, ensuring that pet foods are not only healthful but attractive to companion animals and their owners is essential. The petfood market remains active and requires ongoing evaluation of the adaptation and efficiency of the new products. Palatability-foods' characteristics enticing animals and leading them to consumption-is therefore a key element to look at. Based on the type of information needed, different pet populations (expert or naïve) can be tested to access their preference and acceptance for different food products. Classical techniques are the one-bowl and two-bowl tests, but complementary (i.e., operant conditioning) and novel (i.e., exploratory behavior) approaches are available to gather more information on the evaluation of petfood palatability.
PET imaging in adaptive radiotherapy of prostate tumors.
Beuthien-Baumann, Bettina; Koerber, Stefan A
2018-06-04
The integration of data from positron-emission-tomography, combined with computed tomography as PET/CT or combined with magnet resonance imaging as PET/MRI, into radiation treatment planning of prostate cancer is gaining higher impact with the development of more sensitive and specific radioligands. The classic PET-tracer for prostate cancer imaging are [11C]choline and [11C]acetate, which are currently outperformed by ligands binding to the prostate-specific- membrane-antigen (PSMA). [68Ga]PSMA-11, which is the most frequently applied tracer, has shown to detect lymph node metastases, local recurrences, distant metastases and intraprostatic foci with high sensitivity, even at relatively low PSA levels. The results from PET-imaging may influence radiotherapeutic (RT) management at different stages of the disease i.e. during primary staging or biochemical recurrence, when the detection of distant metastases may alter the curative treatment concept into a palliative approach. On the other hand, the clinical target volume could be adapted by visualizing lymph node metastases at locations, which might not have been suspicious on morphologic imaging alone. The treatment plan might contain a boost to the dominant intraprostatic lesion, which could be delineated by a combination of PET-tracer uptake and multiparametric MRI. Therefore, PSMA-PET imaging is well suited for being integrated into prostate radiation planning. However, further prospective trials evaluating the impact on oncological outcome are indicated.
Production and Applications of Long-Lived Positron-Emitting Radionuclides
NASA Astrophysics Data System (ADS)
Graves, Stephen A.
Positron emission tomography (PET) is a medical imaging modality capable of determining the in vivo spatial distribution of a biologically relevant molecule which has been labeled with a positron-emitting isotope. The use of molecules such as monoclonal antibodies and nanoparticles for therapeutic and diagnostic applications has expanded preclinically in recent years. As these larger molecules tend to have longer circulation times and slow clearance kinetics, positron-emitting isotopes with half-lives longer than conventional medical radioisotopes are required for PET applications. This dissertation details methods for the production of 51Mn (t1/2: 45.4 min), 52gMn (t1/2: 5.59 d), 64Cu (t1/2: 12.7 h), 76Br (t1/2: 16.2 h), 89Zr (t1/2: 3.27 d), and 194Au (t1/2: 38.0 h) on low-energy medical cyclotrons, including targetry considerations, radiochemical separation methods, and analysis of resulting purity. Pursuant to the production of these isotopes, several instrumentation developments have been made including implementation of an automatic nuclide identification library for gamma spectroscopy; development of methods for dead time correction and background estimation in auto-gamma counting; and the creation of a new linearly-filled Derenzo-type PET phantom. Measurement of the radioactive half-lives of 51Mn and 52gMn are presented in addition to their use in a variety of preclinical molecular imaging applications, including immunoPET, stem cell tracking, functional beta-cell mass determination, and probing the impact of isoflurane on acute pancreatic function. An analytic model of effective specific activity is formed and tested against preliminary trace metal analysis results. Measurements of excitation functions for the large-scale production of medically relevant isotopes, including 52gMn, at the Los Alamos National Laboratory Isotope Production Facility (100 MeV p+) are presented. The results described herein have enabled and informed a variety of novel investigations in the fields of nuclear medicine and molecular imaging.
2017 update of the discoveries of nuclides
NASA Astrophysics Data System (ADS)
Thoennessen, M.
The 2017 update of the discovery of nuclide project is presented. 34 new nuclides were observed for the first time in 2017. However, the assignment of six previously identified nuclides had to be retracted.
Griesbeck, Axel G; Reckenthäler, Melissa; Uhlig, Johannes
2010-06-01
The allylic hydroperoxide 2 (myrtenyl hydroperoxide), available from singlet oxygen photooxygenation of beta-pinene (1), is converted into the azido bis-hydroperoxide 3 by an electron-transfer induced azidyl radical formation and trapping of the initial tertiary carbon radical by triplet oxygen. The azido bis-hydroperoxide 3 is reduced to the azido 1,2-diol 4 or the amino diol 5, respectively. Beside classical fluorescent PET sensitizers such as rhodamines, also nanosized semiconductor particles as well as lucigenin were applied as catalysts. The electron transfer rate of azide oxidation was determined for lucigenin by fluorescence quenching analysis.
(18)F-FDG PET/CT findings in a case with HIV (-) Kaposi sarcoma.
Ozdemir, E; Poyraz, N Y; Keskin, M; Kandemir, Z; Turkolmez, S
2014-01-01
Although mucocutaneous sites are the most frequently encountered sites of involvement, Kaposi Sarcoma (KS) may also occasionally involve the breast and the skeletal, endocrine, urinary and nervous systems.. Various imaging modalities may be used to delineate the extent of the disease by detecting unexpected sites of involvement. Herein, we report a case of classical type KS, in whom staging with (18)F-FDG PET/CT imaging disclosed widespread disease and unexpected findings of bone and salivary gland involvement. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.
Balancing risk and benefit in early-stage classical Hodgkin lymphoma.
Bröckelmann, Paul J; Sasse, Stephanie; Engert, Andreas
2018-04-12
With defined chemotherapy and radiotherapy (RT) and risk-adapted treatment, early-stage classical Hodgkin lymphoma (HL) has become curable in a majority of patients. Hence, a major current goal is to reduce treatment-related toxicity while maintaining long-term disease control. Patients with early-stage favorable disease (ie, limited stage without risk factors [RFs]) are frequently treated with 2 cycles of doxorubicin, bleomycin, vinblastine, and dacarbazine (2×ABVD) followed by 20-Gy involved-field or involved-site RT (IF/ISRT). In patients with early-stage unfavorable disease (ie, limited stage with RFs), 4 cycles of chemotherapy are usually consolidated with 30-Gy IF/ISRT. Compared with 4×ABVD, 2 cycles of bleomycin, etoposide, doxorubicin, cyclophosphamide, vincristine, procarbazine, and prednisone (2×BEACOPP escalated ) followed by 2×ABVD improved 5-year progression-free survival (PFS), with similar 5-year overall survival. Recently, treatment strategies based on [ 18 F]fluorodeoxyglucose positron emission tomography (PET) response were evaluated. In early-stage unfavorable HL, a majority of patients achieved a negative interim PET after 2×ABVD and an excellent outcome after 4×ABVD, whereas in those with a positive interim PET, 2×BEACOPP escalated improved 5-year PFS. Furthermore, a PET-guided RT approach was evaluated to decrease long-term toxicity. Although both the RAPID and H10 trials reported poorer disease control without RT, PET-guided omission of RT can constitute a valid therapeutic option in patients with an increased risk of RT-associated toxicity (eg, because of sex, age, or disease localization). Implementation of drugs such as the anti-CD30 antibody-drug conjugate brentuximab vedotin or the anti-programmed death 1 antibodies nivolumab or pembrolizumab might allow further reduction of overall mortality and improve quality of life in affected patients. © 2018 by The American Society of Hematology.
Thomson, Pamela; Monsalves, Pamela; Maier, Liliana; Silva, Víctor
2015-01-01
Dermatophytes are pathogenic fungi that can be present in the flora of mammals, such as dogs, cats and rodents, which can be a source and transmission vehicle to other hosts, including humans. In Chile, there is a steady increase of acquiring guinea pigs (Cavia porcellus) as pets, with no local studies on their colonization by dermatophytes. To determine the presence of dermatophytes on clinically healthy guinea pigs, kept in pet stores in Santiago, Chile. A total of 52 clinically healthy animals were studied using the method by Mariat and Tapia (1966). The specimen culture and identification of the dermatophytes were performed using classical mycological procedures. Four guinea pigs (7.7%) out of 52 were colonized by dermatophytes, and were identified as Trichophyton mentagrophytes (3 cases) and Trichophyton verrucosum (one case). This study shows, for the first time in Chile, that guinea pigs can be colonized by dermatophytes, which should alert administrators of pet stores, veterinarians and physicians, to keep this in mind when purchasing or looking after this type of pet in a veterinary office. Copyright © 2013 Revista Iberoamericana de Micología. Published by Elsevier Espana. All rights reserved.
Rösch, Frank; Herzog, Hans; Qaim, Syed M.
2017-01-01
In the context of radiopharmacy and molecular imaging, the concept of theranostics entails a therapy-accompanying diagnosis with the aim of a patient-specific treatment. Using the adequate diagnostic radiopharmaceutical, the disease and the state of the disease are verified for an individual patient. The other way around, it verifies that the radiopharmaceutical in hand represents a target-specific and selective molecule: the “best one” for that individual patient. Transforming diagnostic imaging into quantitative dosimetric information, the optimum radioactivity (expressed in maximum radiation dose to the target tissue and tolerable dose to healthy organs) of the adequate radiotherapeutical is applied to that individual patient. This theranostic approach in nuclear medicine is traced back to the first use of the radionuclide pair 86Y/90Y, which allowed a combination of PET and internal radiotherapy. Whereas the β-emitting therapeutic radionuclide 90Y (t½ = 2.7 d) had been available for a long time via the 90Sr/90Y generator system, the β+ emitter 86Y (t½ = 14.7 h) had to be developed for medical application. A brief outline of the various aspects of radiochemical and nuclear development work (nuclear data, cyclotron irradiation, chemical processing, quality control, etc.) is given. In parallel, the paper discusses the methodology introduced to quantify molecular imaging of 86Y-labelled compounds in terms of multiple and long-term PET recordings. It highlights the ultimate goal of radiotheranostics, namely to extract the radiation dose of the analogue 90Y-labelled compound in terms of mGy or mSv per MBq 90Y injected. Finally, the current and possible future development of theranostic approaches based on different PET and therapy nuclides is discussed. PMID:28632200
Phillips, W.M.; Hall, A.M.; Mottram, R.; Fifield, L.K.; Sugden, D.E.
2006-01-01
The occurrence of tors within glaciated regions has been widely cited as evidence for the preservation of relic pre-Quaternary landscapes beneath protective covers of non-erosive dry-based ice. Here, we test for the preservation of pre-Quaternary landscapes with cosmogenic surface exposure dating of tors. Numerous granite tors are present on summit plateaus in the Cairngorm Mountains of Scotland where they were covered by local ice caps many times during the Pleistocene. Cosmogenic 10Be and 26Al data together with geomorphic relationships reveal that these landforms are more dynamic and younger than previously suspected. Many Cairngorm tors have been bulldozed and toppled along horizontal joints by ice motion, leaving event surfaces on tor remnants and erratics that can be dated with cosmogenic nuclides. As the surfaces have been subject to episodic burial by ice, an exposure model based upon ice and marine sediment core proxies for local glacial cover is necessary to interpret the cosmogenic nuclide data. Exposure ages and weathering characteristics of tors are closely correlated. Glacially modified tors and boulder erratics with slightly weathered surfaces have 10Be exposure ages of about 15 to 43 ka. Nuclide inheritance is present in many of these surfaces. Correction for inheritance indicates that the eastern Cairngorms were deglaciated at 15.6 ?? 0.9 ka. Glacially modified tors with moderate to advanced weathering features have 10Be exposure ages of 19 to 92 ka. These surfaces were only slightly modified during the last glacial cycle and gained much of their exposure during the interstadial of marine Oxygen Isotope Stage 5 or earlier. Tors lacking evidence of glacial modification and exhibiting advanced weathering have 10Be exposure ages between 52 and 297 ka. Nuclide concentrations in these surfaces are probably controlled by bedrock erosion rates instead of discrete glacial events. Maximum erosion rates estimated from 10Be range from 2.8 to 12.0 mm/ka, with an error weighted mean of 4.1 ?? 0.2 mm/ka. Three of these surfaces yield model exposure-plus-burial ages of 295-71+84, 520-141+178, and 626-85+102 ka. A vertical cosmogenic nuclide profile across the oldest sampled tor indicates a long-term emergence rate of 31 ?? 2 mm/ka. These findings show that dry-based ice caps are capable of substantially eroding tors by entraining blocks previously detached by weathering processes. Bedrock surfaces and erratic boulders in such settings are likely to have nuclide inheritance and may yield erroneous (too old) exposure ages. While many Cairngorm tors have survived multiple glacial cycles, rates of regolith stripping and bedrock erosion are too high to permit the widespread preservation of pre-Quaternary rock surfaces. ?? 2005 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soti, Zsolt; Magill, Joseph; Pfennig, Gerda
Following the success of the 8. Edition of the Karlsruhe Nuclide Chart 2012, a new edition is planned for 2015. Since the 2012 edition, more than 100 nuclides have been discovered and about 1400 nuclides have been updated. In summary, the new 9. edition contains decay and radiation data on approximately 3230 ground state nuclides and 740 isomers from 118 chemical elements. The accompanying booklet provides a detailed explanation of the nuclide box structure used in the Chart. An expanded section contains many additional nuclide decay schemes to aid the user to interpret the highly condensed information in the nuclidemore » boxes. The booklet contains - in addition to the latest values of the physical constants and physical properties - a periodic table of the elements, tables of new and updated nuclides, and a difference chart showing the main changes in the Chart graphically. (authors)« less
Cosmic-Ray Nucleosynthesis of p-nuclei: Yields and Routes
NASA Astrophysics Data System (ADS)
Kusakabe, Motohiko; Mathews, Grant J.
2018-02-01
We investigate the cosmic-ray nucleosynthesis (CRN) of proton-rich stable nuclides (p-nuclides). We calculate the cosmic-ray (CR) energy spectra of heavy nuclides with mass number A=[74,209], taking into account the detailed nuclear spallation, decay, energy loss, and escape from the Galaxy during the CR propagation. We adopt the latest semiempirical formula SPACS for the spallation cross sections and the latest data on nuclear decay. Effective electron-capture decay rates are calculated using the proper cross sections for recombination and ionization in the whole CR energy region. Calculated CR spectral shapes vary for different nuclides. Abundances of proton-rich unstable nuclides increase in CRs with increasing energy relative to those of other nuclides. Yields of the primary and secondary spallation processes and differential yields from respective seed nuclides are calculated. We find that the CR energy region of ≤slant { \\mathcal O }(100) MeV/nucleon predominantly contributes to the total yields. The atomic cross sections in the low-energy range adopted in this study are then necessary. Effects of CRN on the Galactic chemical evolution of p-nuclides are calculated. Important seed nuclides are identified for respective p-nuclides. The contribution of CRN is significant for 180m Ta, accounting for about 20% of the solar abundance. About 87% of the 180m Ta CRN yield can be attributed to the primary process. The most important production routes are reactions of 181Ta, 180Hf, and 182W. CRN yields of other p-nuclides are typically about { \\mathcal O }(10‑4–10‑2) of solar abundances.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radchenko, Valery; Meyer, Catherine Anne Louise; Engle, Jonathan Ward
Scandium-44 g (half-life 3.97 h) shows promise for positron emission tomography (PET) imaging of longer biological processes than that of the current gold standard, 18F, due to its favorable decay parameters. One source of 44gSc is the long-lived parent nuclide 44Ti (half-life 60.0 a). A 44Ti/ 44gSc generator would have the ability to provide radionuclidically pure 44gSc on a daily basis. The production of 44Ti via the 45Sc(p,2n) reaction requires high proton beam currents and long irradiation times. Recovery and purification of no-carrier added (nca) 44Ti from scandium metal targets involves complex separation chemistry. In this study, separation systems basedmore » on solid phase extraction chromatography were investigated, including branched diglycolamide (BDGA) resin and hydroxamate based ZR resin. Lastly, results indicate that ZR resin in HCl media represents an effective 44Ti/ 44gSc separation system.« less
T L'Estrade, Elina; Hansen, Hanne D; Erlandsson, Maria; Ohlsson, Tomas G; Knudsen, Gitte M; Herth, Matthias M
2018-06-20
Already in 1953, Woolley and Shaw speculated that serotonin could be involved in a range of central nervous system (CNS) disorders. Lysergic acid diethylamide (LSD) displayed an important role in this respect. It was used not only to antagonize biological effects of serotonin and to study the system itself, but also to identify serotonergic subtype receptors. The 5-HT 2A receptor was discovered in the 1970s and identified as the responsible receptor mediating psychedelic effects of LSD. The development of positron emission tomography (PET) allowed to study this receptor system in vivo. Parameters such as abundance of 5-HT 2A neuroreceptors or receptor occupancy can be determined using PET. As such, the development of 5-HT 2A receptor tracers started immediately after the introduction of PET in the mid-1970s. In this Viewpoint, we provide a historical overview from the discovery of serotonin to the identification of the 5-HT 2A receptor subtype and the subsequent development of 5-HT 2A receptor subtype specific PET tracers over the last four decades. We emphasize the interplay between pharmacology, medicinal chemistry, radiochemistry, and nuclear medicine that is important while developing a PET tracer. Moreover, we highlight selected examples applying 5-HT 2A receptor PET tracers within neurological diseases and drug occupancy studies.
Ge14 Br8 (PEt3 )4 : A Subhalide Cluster of Germanium.
Kunz, Tanja; Schrenk, Claudio; Schnepf, Andreas
2018-04-03
Heating a metastable solution of Ge I Br to room temperature led to the first structurally characterized metalloid subhalide cluster Ge 14 Br 8 (PEt 3 ) 4 (1). Furthermore 1 can be seen as the first isolated binary halide cluster on the way from Ge I Br to elemental germanium, giving insight into the complex reaction mechanism of its disproportionation reaction. Quantum chemical calculations further indicate that a classical bonding situation is realized within 1 and that the last step of the formation of 1 might include the trapping of GeBr 2 units. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Targeted alpha therapy of mCRPC: Dosimetry estimate of 213Bismuth-PSMA-617.
Kratochwil, Clemens; Schmidt, Karl; Afshar-Oromieh, Ali; Bruchertseifer, Frank; Rathke, Hendrik; Morgenstern, Alfred; Haberkorn, Uwe; Giesel, Frederik L
2018-01-01
PSMA-617 is a small molecule targeting the prostate-specific membrane antigen (PSMA). In this work, we estimate the radiation dosimetry for this ligand labeled with the alpha-emitter 213 Bi. Three patients with metastatic prostate cancer underwent PET scans 0.1 h, 1 h, 2 h, 3 h, 4 h and 5 h after injection of 68 Ga-PSMA-617. Source organs were kidneys, liver, spleen, salivary glands, bladder, red marrow and representative tumor lesions. The imaging nuclide 68 Ga was extrapolated to the half-life of 213 Bi. The residence times of 213 Bi were forwarded to the instable daughter nuclides. OLINDA was used for dosimetry calculation. Results are discussed in comparison to literature data for 225 Ac-PSMA-617. Assuming a relative biological effectiveness of 5 for alpha radiation, the dosimetry estimate revealed equivalent doses of mean 8.1 Sv RBE5 /GBq for salivary glands, 8.1 Sv RBE5 /GBq for kidneys and 0.52 Sv RBE5 /GBq for red marrow. Liver (1.2 Sv RBE5 /GBq), spleen (1.4 Sv RBE5 /GBq), bladder (0.28 Sv RBE5 /GBq) and other organs (0.26 Sv RBE5 /GBq) were not dose-limiting. The effective dose is 0.56 Sv RBE5 /GBq. Tumor lesions were in the range 3.2-9.0 Sv RBE5 /GBq (median 7.6 Sv RBE5 /GBq). Kidneys would limit the cumulative treatment activity to 3.7 GBq; red marrow might limit the maximum single fraction to 2 GBq. Despite promising results, the therapeutic index was inferior compared to 225 Ac-PSMA-617. Dosimetry of 213 Bi-PSMA-617 is in a range traditionally considered reasonable for clinical application. Nevertheless, compared to 225 Ac-PSMA-617, it suffers from higher perfusion-dependent off-target radiation and a longer biological half-life of PSMA-617 in dose-limiting organs than the physical half-life of 213 Bi, rendering this nuclide as a second choice radiolabel for targeted alpha therapy of prostate cancer.
NASA Astrophysics Data System (ADS)
Boisson, F.; Wimberley, C. J.; Lehnert, W.; Zahra, D.; Pham, T.; Perkins, G.; Hamze, H.; Gregoire, M.-C.; Reilhac, A.
2013-10-01
Monte Carlo-based simulation of positron emission tomography (PET) data plays a key role in the design and optimization of data correction and processing methods. Our first aim was to adapt and configure the PET-SORTEO Monte Carlo simulation program for the geometry of the widely distributed Inveon PET preclinical scanner manufactured by Siemens Preclinical Solutions. The validation was carried out against actual measurements performed on the Inveon PET scanner at the Australian Nuclear Science and Technology Organisation in Australia and at the Brain & Mind Research Institute and by strictly following the NEMA NU 4-2008 standard. The comparison of simulated and experimental performance measurements included spatial resolution, sensitivity, scatter fraction and count rates, image quality and Derenzo phantom studies. Results showed that PET-SORTEO reliably reproduces the performances of this Inveon preclinical system. In addition, imaging studies showed that the PET-SORTEO simulation program provides raw data for the Inveon scanner that can be fully corrected and reconstructed using the same programs as for the actual data. All correction techniques (attenuation, scatter, randoms, dead-time, and normalization) can be applied on the simulated data leading to fully quantitative reconstructed images. In the second part of the study, we demonstrated its ability to generate fast and realistic biological studies. PET-SORTEO is a workable and reliable tool that can be used, in a classical way, to validate and/or optimize a single PET data processing step such as a reconstruction method. However, we demonstrated that by combining a realistic simulated biological study ([11C]Raclopride here) involving different condition groups, simulation allows one also to assess and optimize the data correction, reconstruction and data processing line flow as a whole, specifically for each biological study, which is our ultimate intent.
Han, Xue-Di; Liu, Chen; Liu, Fei; Xie, Qing-Hua; Liu, Te-Li; Guo, Xiao-Yi; Xu, Xiao-Xia; Yang, Xing; Zhu, Hua; Yang, Zhi
2017-09-26
Here, we report that it's feasible for imaging gastric adenocarcinoma mice model with prostate-specific membrane antigen (PSMA) targeting imaging agents, which could potentially provide an alternate and readily translational tool for managing gastric adenocarcinoma. DKFZ-PSMA-617, a PSMA targeting ligand reported recently, was chosen to be radio-labeled with nuclide 64 Cu. 64 Cu-PSMA-617 was radio-synthesized in high radio-chemical yield and specific activity up to 19.3 GBq/µmol. It showed good stability in vitro . The specificity of 64 Cu-PSMA-617 was confirmed by cell uptake experiments in PSMA (+) LNCaP cell and PSMA (-) PC-3 and gastric adenocarcinoma BGC-823 cells. Micro-PET imaging in BGC-823 and PC-3 xenografts nude mice was evaluated ( n = 4). And the tumors were visualized and better tumor-to-background achieved till 24 h. Co-administration of N- [[[(1S)-1-Carboxy-3-methylbutyl]amino]-carbonyl]-L-glutamic acid (ZJ-43) can substantially block the uptake in those tumors. Dissected tumor tissues were analyzed by auto-radiography and immunohistochemistry, and these results confirmed the PSMA expression in neo-vasculature which explained the target molecular imaging of 64 Cu-PSMA-617. All those results suggested 64 Cu-PSMA-617 may serve as a novel radio-tracer for tumor imaging more than prostate cancer.
Han, Xue-Di; Liu, Chen; Liu, Fei; Xie, Qing-Hua; Liu, Te-Li; Guo, Xiao-Yi; Xu, Xiao-Xia; Yang, Xing; Zhu, Hua; Yang, Zhi
2017-01-01
Here, we report that it’s feasible for imaging gastric adenocarcinoma mice model with prostate-specific membrane antigen (PSMA) targeting imaging agents, which could potentially provide an alternate and readily translational tool for managing gastric adenocarcinoma. DKFZ-PSMA-617, a PSMA targeting ligand reported recently, was chosen to be radio-labeled with nuclide 64Cu. 64Cu-PSMA-617 was radio-synthesized in high radio-chemical yield and specific activity up to 19.3 GBq/µmol. It showed good stability in vitro. The specificity of 64Cu-PSMA-617 was confirmed by cell uptake experiments in PSMA (+) LNCaP cell and PSMA (-) PC-3 and gastric adenocarcinoma BGC-823 cells. Micro-PET imaging in BGC-823 and PC-3 xenografts nude mice was evaluated (n = 4). And the tumors were visualized and better tumor-to-background achieved till 24 h. Co-administration of N- [[[(1S)-1-Carboxy-3-methylbutyl]amino]-carbonyl]-L-glutamic acid (ZJ-43) can substantially block the uptake in those tumors. Dissected tumor tissues were analyzed by auto-radiography and immunohistochemistry, and these results confirmed the PSMA expression in neo-vasculature which explained the target molecular imaging of 64Cu-PSMA-617. All those results suggested 64Cu-PSMA-617 may serve as a novel radio-tracer for tumor imaging more than prostate cancer. PMID:29088775
Counseling with Pocket Pets: Using Small Animals in Elementary Counseling Programs
ERIC Educational Resources Information Center
Flom, Barbara L.
2005-01-01
The power of the human-animal bond has been described in sources as diverse as ancient literature, modern fiction, and research reports in the professional literature (Chandler, 2001; Mallon, 1992; Parshall, 2003; Siegel, 1993). Educators have used classic examples, such as those found in the children's books Old Yeller and Where the Red Fern…
Biotechnological advances in the diagnosis of little-known parasitoses of pets.
Traversa, Donato; Otranto, Domenico
2009-01-01
Dogs, cats, and horses are popular pets in many countries of the World and they have lived in close proximity with human beings for thousands of years. The effect of pet ownership on human health is well known and there is significant merit in preserving the health and welfare of these animals. Some infections caused by parasitic nematodes and arthropods of dogs, cats, and horses are now spreading in several areas of the world. This is the case of canine spirocercosis, feline aelurostrongylosis, and equine gastro-intestinal and nasal nematode and botfly infections. These diseases affect animal health and welfare and may be life-threatening. In spite these infections causing illnesses of major importance in clinical practice are spreading in new geographical foci, they are little known and underestimated also as an effect of difficulties in traditional diagnostics. Importantly, the limited reliability of conventional methodologies has also limited our knowledge of epidemiology, ecology, and biology of these parasitoses. This article reviews the DNA-based assays that have been recently developed for diagnosing these neglected pet parasitic diseases focusing on the advantages they have over classical techniques. Moreover, the opportunities for further epidemiological, ecological, and biological investigations are discussed.
β Decay as a Probe of Explosive Nucleosynthesis in Classical Novae
NASA Astrophysics Data System (ADS)
Wrede, C.; Bennett, M. B.; Liddick, S. N.; Bardayan, D. W.; Bowe, A.; Brown, B. A.; Chen, A. A.; Chipps, K. A.; Cooper, N.; Fry, C.; Glassman, B.; Irvine, D.; José, J.; Langer, C.; Larson, N.; McNeice, E. I.; Meisel, Z.; Montes, F.; Naqvi, F.; Pain, S. D.; O'Malley, P.; Ortez, R.; Ong, W.; Pereira, J.; Pérez-Loureiro, D.; Prokop, C.; Quaglia, J.; Quinn, S.; Santia, M.; Schatz, H.; Schwartz, S. B.; Simon, A.; Shanab, S.; Spyrou, A.; Suchyta, S.; Thiagalingam, E.; Thompson, P.; Walters, M.
Classical novae are common thermonuclear explosions in the Milky Way galaxy, occurring on the surfaces of white-dwarf stars that are accreting hydrogen-rich material from companion stars. Nucleosynthesis in classical novae depends on radiative proton-capture reaction rates on radioactive nuclides. Many of these reactions cannot be measured directly at current accelerator facilities due to the lack of intense, high-quality, radioactive-ion beams at the relevant energies. Since most of these reactions proceed via resonant capture, their rates can be determined indirectly by measuring the properties of the resonances. At the National Superconducting Cyclotron Laboratory, we have used the β-delayed γ decays of 26P and 31Cl to populate resonances in 26Si and 31S and study the radiative proton captures on 25Al and 30P, respectively. These were two out of the three most important nuclear-physics uncertainties associated with the observable products of nova nucleosynthesis. The 26P experiment has enabled a more accurate estimate of the nova contribution to the long-lived Galactic 26Al detected with γ-ray telescopes. The 31Cl experiment, currently under analysis, will calibrate potential nova thermometers and mixing meters based on elemental abundance ratios, and facilitate the identification of pre-solar nova grain candidates found in primitive meteorites based on isotopic ratios.
Assessing Food Preferences in Dogs and Cats: A Review of the Current Methods
Tobie, Christelle; Péron, Franck; Larose, Claire
2015-01-01
Simple Summary The objective of this review is to present the different approaches and techniques used to assess petfood palatability, either with expert panels or naïve individuals (in-home panels). Abstract Food is a major aspect of pet care; therefore, ensuring that pet foods are not only healthful but attractive to companion animals and their owners is essential. The petfood market remains active and requires ongoing evaluation of the adaptation and efficiency of the new products. Palatability—foods’ characteristics enticing animals and leading them to consumption—is therefore a key element to look at. Based on the type of information needed, different pet populations (expert or naïve) can be tested to access their preference and acceptance for different food products. Classical techniques are the one-bowl and two-bowl tests, but complementary (i.e., operant conditioning) and novel (i.e., exploratory behavior) approaches are available to gather more information on the evaluation of petfood palatability. PMID:26479142
Mounier, Nicolas; Nicolas, Mounier; Gisselbrecht, Christian; Christian, Gisselbrecht
2015-04-01
This review discusses promising new approaches in classical Hodgkin's lymphoma that have been recently evaluated. There is a focus on the fluorodeoxyglucose PET scanning that is now considered crucial for staging and treatment evaluation, including interim evaluation after two cycles. An up-front treatment strategy is discussed, with the place of radiation therapy and the difficult choice of chemotherapy intensity emphasized. Indications for frail patients are also reviewed, particularly elderly or HIV-positive patients. Emerging data on the antibody drug conjugate brentuximab vedotin and its future potential in the transplantation framework for relapsed/refractory Hodgkin's lymphoma is also discussed.
Alpha-emitting nuclides in the marine environment
NASA Astrophysics Data System (ADS)
Pentreath, R. J.
1984-06-01
The occurrence of alpha-emitting nuclides and their daughter products in the marine environment continues to be a subject of study for many reasons. Those nuclides which occur naturally, in the uranium, thorium and actinium series, are of interest because of their value in determining the rates of geological and geochemical processes in the oceans. Studies of them address such problems as the determination of rates of transfer of particulate matter, deposition rates, bioturbation rates, and so on. Two of the natural alpha-series nuclides in which a different interest has been expressed are 210Po and 226Ra, because their concentrations in marine organisms are such that they contribute to a significant fraction of the background dose rates sustained both by the organisms themselves and by consumers of marine fish and shellfish. To this pool of naturally-occurring nuclides, human activities have added the transuranium nuclides, both from the atmospheric testing of nuclear devices and from the authorized discharges of radioactive wastes into coastal waters and the deep sea. Studies have therefore been made to understand the chemistry of these radionuclides in sea water, their association with sedimentary materials, and their accumulation by marine organisms, the last of these being of particular interest because the transuranics are essentially "novel" elements to the marine fauna and flora. The need to predict the long-term behaviour of these nuclides has, in turn, stimulated research on those naturally-occurring nuclides which may behave in a similar manner.
Addressing the third gamma problem in PET
NASA Astrophysics Data System (ADS)
Schueller, M. J.; Mulnix, T. L.; Christian, B. T.; Jensen, M.; Holm, S.; Oakes, T. R.; Roberts, A. D.; Dick, D. W.; Martin, C. C.; Nickles, R. J.
2003-02-01
PET brings the promise of quantitative imaging of the in-vivo distribution of any positron emitting nuclide, a list with hundreds of candidates. All but a few of these, the "pure positron" emitters, have isotropic coincident gamma rays that give rise to misrepresented events in the sinogram and in the resulting reconstructed image. Of particular interest are /sup 10/C, /sup 14/O, /sup 38/K, /sup 52m/Mn, /sup 60/Cu, /sup 61/Cu, /sup 94m/Tc, and /sup 124/I, each having high-energy gammas that are Compton-scattered down into the 511 keV window. The problems arising from the "third gamma," and its accommodation by standard scatter correction algorithms, were studied empirically, employing three scanner models (CTI 933/04, CTI HR+ and GE Advance), imaging three phantoms (line source, NEMA scatter and contrast/detail), with /sup 18/F or /sup 38/K and /sup 72/As mimicking /sup 14/O and /sup 10/C, respectively, in 2-D and 3-D modes. Five findings emerge directly from the image analysis. The third gamma: 1) does, obviously, tax the single event rate of the PET scanners, particularly in the absence of septa, from activity outside of the axial field of view; 2) does, therefore, tax the random rate, which is second order in singles, although the gamma is a prompt coincidence partner; 3) does enter the sinogram as an additional flat background, like randoms, but unlike scatter; 4) is not seriously misrepresented by the scatter algorithm which fits the correction to the wings of the sinogram; and 5) does introduce additional statistical noise from the subsequent subtraction, but does not seriously compromise the detectability of lesions as seen in the contrast/detail phantom. As a safeguard against the loss of accuracy in image quantitation, fiducial sources of known activity are included in the field of view alongside of the subject. With this precaution, a much wider selection of imaging agents can enjoy the advantages of positron emission tomography.
Ogawa, Kazuma; Ishizaki, Atsushi; Takai, Kenichiro; Kitamura, Yoji; Kiwada, Tatsuto; Shiba, Kazuhiro; Odani, Akira
2013-01-01
68Ga (T 1/2 = 68 min, a generator-produced nuclide) has great potential as a radionuclide for clinical positron emission tomography (PET). Because poly-glutamic and poly-aspartic acids have high affinity for hydroxyapatite, to develop new bone targeting 68Ga-labeled bone imaging agents for PET, we used 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) as a chelating site and conjugated aspartic acid peptides of varying lengths. Subsequently, we compared Ga complexes, Ga-DOTA-(Asp)n (n = 2, 5, 8, 11, or 14) with easy-to-handle 67Ga, with the previously described 67Ga-DOTA complex conjugated bisphosphonate, 67Ga-DOTA-Bn-SCN-HBP. After synthesizing DOTA-(Asp)n by a Fmoc-based solid-phase method, complexes were formed with 67Ga, resulting in 67Ga-DOTA-(Asp)n with a radiochemical purity of over 95% after HPLC purification. In hydroxyapatite binding assays, the binding rate of 67Ga-DOTA-(Asp)n increased with the increase in the length of the conjugated aspartate peptide. Moreover, in biodistribution experiments, 67Ga-DOTA-(Asp)8, 67Ga-DOTA-(Asp)11, and 67Ga-DOTA-(Asp)14 showed high accumulation in bone (10.5±1.5, 15.1±2.6, and 12.8±1.7% ID/g, respectively) but were barely observed in other tissues at 60 min after injection. Although bone accumulation of 67Ga-DOTA-(Asp)n was lower than that of 67Ga-DOTA-Bn-SCN-HBP, blood clearance of 67Ga-DOTA-(Asp)n was more rapid. Accordingly, the bone/blood ratios of 67Ga-DOTA-(Asp)11 and 67Ga-DOTA-(Asp)14 were comparable with those of 67Ga-DOTA-Bn-SCN-HBP. In conclusion, these data provide useful insights into the drug design of 68Ga-PET tracers for the diagnosis of bone disorders, such as bone metastases. PMID:24391942
Li, Hongli; Schöder, Heiko; Straus, David J.; Moskowitz, Craig H.; LeBlanc, Michael; Rimsza, Lisa M.; Bartlett, Nancy L.; Evens, Andrew M.; Mittra, Erik S.; LaCasce, Ann S.; Sweetenham, John W.; Barr, Paul M.; Fanale, Michelle A.; Knopp, Michael V.; Noy, Ariela; Hsi, Eric D.; Cook, James R.; Lechowicz, Mary Jo; Gascoyne, Randy D.; Leonard, John P.; Kahl, Brad S.; Cheson, Bruce D.; Fisher, Richard I.; Friedberg, Jonathan W.
2016-01-01
Purpose Four US National Clinical Trials Network components (Southwest Oncology Group, Cancer and Leukemia Group B/Alliance, Eastern Cooperative Oncology Group, and the AIDS Malignancy Consortium) conducted a phase II Intergroup clinical trial that used early interim fluorodeoxyglucose positron emission tomography (FDG-PET) imaging to determine the utility of response-adapted therapy for stage III to IV classic Hodgkin lymphoma. Patients and Methods The Southwest Oncology Group S0816 (Fludeoxyglucose F 18-PET/CT Imaging and Combination Chemotherapy With or Without Additional Chemotherapy and G-CSF in Treating Patients With Stage III or Stage IV Hodgkin Lymphoma) trial enrolled 358 HIV-negative patients between July 1, 2009, and December 2, 2012. A PET scan was performed after two initial cycles of doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD) and was labeled PET2. PET2-negative patients (Deauville score 1 to 3) received an additional four cycles of ABVD, whereas PET2-positive patients (Deauville score 4 to 5) were switched to escalated bleomycin, etoposide, doxorubicin, cyclophosphamide, vincristine, procarbazine, and prednisone (eBEACOPP) for six cycles. Among 336 eligible and evaluable patients, the median age was 32 years (range, 18 to 60 years), with 52% stage III, 48% stage IV, 49% International Prognostic Score 0 to 2, and 51% score 3 to 7. Results Three hundred thirty-six of the enrolled patients were evaluable. Central review of the interim PET2 scan was performed in 331 evaluable patients, with 271 (82%) PET2-negative and 60 (18%) PET2-positive. Of 60 eligible PET2-positive patients, 49 switched to eBEACOPP as planned and 11 declined. With a median follow-up of 39.7 months, the Kaplan-Meier estimate for 2-year overall survival was 98% (95% CI, 95% to 99%), and the 2-year estimate for progression-free survival (PFS) was 79% (95% CI, 74% to 83%). The 2-year estimate for PFS in the subset of patients who were PET2-positive after two cycles of ABVD was 64% (95% CI, 50% to 75%). Both nonhematologic and hematologic toxicities were greater in the eBEACOPP arm than in the continued ABVD arm. Conclusion Response-adapted therapy based on interim PET imaging after two cycles of ABVD seems promising with a 2-year PFS of 64% for PET2-positive patients, which is much higher than the expected 2-year PFS of 15% to 30%. PMID:27069074
Computer program FPIP-REV calculates fission product inventory for U-235 fission
NASA Technical Reports Server (NTRS)
Brown, W. S.; Call, D. W.
1967-01-01
Computer program calculates fission product inventories and source strengths associated with the operation of U-235 fueled nuclear power reactor. It utilizes a fission-product nuclide library of 254 nuclides, and calculates the time dependent behavior of the fission product nuclides formed by fissioning of U-235.
A new nuclide transport model in soil in the GENII-LIN health physics code
NASA Astrophysics Data System (ADS)
Teodori, F.
2017-11-01
The nuclide soil transfer model, originally included in the GENII-LIN software system, was intended for residual contamination from long term activities and from waste form degradation. Short life nuclides were supposed absent or at equilibrium with long life parents. Here we present an enhanced soil transport model, where short life nuclide contributions are correctly accounted. This improvement extends the code capabilities to handle incidental release of contaminant to soil, by evaluating exposure since the very beginning of the contamination event, before the radioactive decay chain equilibrium is reached.
Niedermoser, Sabrina; Chin, Joshua; Wängler, Carmen; Kostikov, Alexey; Bernard-Gauthier, Vadim; Vogler, Nils; Soucy, Jean-Paul; McEwan, Alexander J; Schirrmacher, Ralf; Wängler, Björn
2015-07-01
Radiolabeled peptides for tumor imaging with PET that can be produced with kits are currently in the spotlight of radiopharmacy and nuclear medicine. The diagnosis of neuroendocrine tumors in particular has been a prime example for the usefulness of peptides labeled with a variety of different radionuclides. Among those, (68)Ga and (18)F stand out because of the ease of radionuclide introduction (e.g., (68)Ga isotope) or optimal nuclide properties for PET imaging (slightly favoring the (18)F isotope). The in vivo properties of good manufacturing practice-compliant, newly developed kitlike-producible (18)F-SiFA- and (18)F-SiFAlin- (SiFA = silicon-fluoride acceptor) modified TATE derivatives were compared with the current clinical gold standard (68)Ga-DOTATATE for high-quality imaging of somatostatin receptor-bearing tumors. SiFA- and SiFAlin-derivatized somatostatin analogs were synthesized and radiolabeled using cartridge-based dried (18)F and purified via a C18 cartridge (radiochemical yield 49.8% ± 5.9% within 20-25 min) without high-performance liquid chromatography purification. Tracer lipophilicity and stability in human serum were tested in vitro. Competitive receptor binding affinity studies were performed using AR42J cells. The most promising tracers were evaluated in vivo in an AR42J xenograft mouse model by ex vivo biodistribution and in vivo PET/CT imaging studies for evaluation of their pharmacokinetic profiles, and the results were compared with those of the current clinical gold standard (68)Ga-DOTATATE. Synthetically easily accessible (18)F-labeled silicon-fluoride acceptor-modified somatostatin analogs were developed. They exhibited high binding affinities to somatostatin receptor-positive tumor cells (1.88-14.82 nM). The most potent compound demonstrated comparable pharmacokinetics and an even slightly higher absolute tumor accumulation level in ex vivo biodistribution studies as well as higher tumor standardized uptake values in PET/CT imaging than (68)Ga-DOTATATE in vivo. The radioactivity uptake in nontumor tissue was higher than for (68)Ga-DOTATATE. The introduction of the novel SiFA building block SiFAlin and of hydrophilic auxiliaries enables a favorable in vivo biodistribution profile of the modified TATE peptides, resulting in high tumor-to-background ratios although lower than those observed with (68)Ga-DOTATATE. As further advantage, the SiFA methodology enables a kitlike labeling procedure for (18)F-labeled peptides advantageous for routine clinical application. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Surficial Studies of Mars Using Cosmogenic Nuclides
NASA Technical Reports Server (NTRS)
Nishiizumi, K.
2001-01-01
Cosmogenic nuclides (CNs) are produced by cosmic-ray nuclear interactions with target nuclei in rocks, soils, ice, and the atmosphere. Cosmogenic nuclides have been widely used for investigation of solar system matter for several decades. Stable nuclides, such as He-3, Ne-21, and Ar-38, are built up over time as the surface is exposed to cosmic rays. The concentrations of cosmogenic radionuclides, such as Be-10, Al-26, and C-14 also build up with exposure time but reach saturation values after several half-lives. Especially since the development of accelerator mass spectrometry (AMS), CNs in terrestrial samples have been routinely used for geomorphic studies such as glaciation, surface erosion, and tectonics, and studies of atmospheric and ocean circulation. Cosmogenic nuclides on Mars will be able to answer questions of exposure ages, erosion rates, tectonic events, and deposition rates of sediments and/or volatiles. The concentrations of cosmogenic stable nuclides give the integrated exposure time of the rock/mineral, and the activities of radionuclides give recent records for times back as long as a few half-lives.
Dynamic neurotransmitter interactions measured with PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiffer, W.K.; Dewey, S.L.
2001-04-02
Positron emission tomography (PET) has become a valuable interdisciplinary tool for understanding physiological, biochemical and pharmacological functions at a molecular level in living humans, whether in a healthy or diseased state. The utility of tracing chemical activity through the body transcends the fields of cardiology, oncology, neurology and psychiatry. In this, PET techniques span radiochemistry and radiopharmaceutical development to instrumentation, image analysis, anatomy and modeling. PET has made substantial contributions in each of these fields by providing a,venue for mapping dynamic functions of healthy and unhealthy human anatomy. As diverse as the disciplines it bridges, PET has provided insight intomore » an equally significant variety of psychiatric disorders. Using the unique quantitative ability of PET, researchers are now better able to non-invasively characterize normally occurring neurotransmitter interactions in the brain. With the knowledge that these interactions provide the fundamental basis for brain response, many investigators have recently focused their efforts on an examination of the communication between these chemicals in both healthy volunteers and individuals suffering from diseases classically defined as neurotransmitter specific in nature. In addition, PET can measure the biochemical dynamics of acute and sustained drug abuse. Thus, PET studies of neurotransmitter interactions enable investigators to describe a multitude of specific functional interactions in the human brain. This information can then be applied to understanding side effects that occur in response to acute and chronic drug therapy, and to designing new drugs that target multiple systems as opposed to single receptor types. Knowledge derived from PET studies can be applied to drug discovery, research and development (for review, see (Fowler et al., 1999) and (Burns et al., 1999)). Here, we will cover the most substantial contributions of PET to understanding biologically distinct neurochemical systems that interact to produce a variety of behaviors and disorders. Neurotransmitters are neither static nor isolated in their distribution. In fact, it is through interactions with other neurochemically distinct systems that the central nervous system (CNS) performs its vital role in sustaining life. Exclusive quantitative capabilities intrinsic to PET make this technology a suitable experimental tool to measure not only the regional distribution of specific receptors and their subtypes, but also the dynamic properties of neuroreceptors and their inherent influence on related neurotransmitter pathways. The ability to investigate dynamic properties in a non-invasive and reproducible manner provides a powerful tool that can extend our current knowledge of these interactions. Coupled with innovative paradigms including pharmacologic manipulations, physiologic models and reconstruction theories, knowledge derived from PET studies can greatly advance our understanding of normal and abnormal brain function.« less
Ben Bouallègue, Fayçal; Vauchot, Fabien; Mariano-Goulart, Denis; Payoux, Pierre
2018-02-09
We evaluated the performance of amyloid PET textural and shape features in discriminating normal and Alzheimer's disease (AD) subjects, and in predicting conversion to AD in subjects with mild cognitive impairment (MCI) or significant memory concern (SMC). Subjects from the Alzheimer's Disease Neuroimaging Initiative with available baseline 18 F-florbetapir and T1-MRI scans were included. The cross-sectional cohort consisted of 181 controls and 148 AD subjects. The longitudinal cohort consisted of 431 SMC/MCI subjects, 85 of whom converted to AD during follow-up. PET images were normalized to MNI space and post-processed using in-house software. Relative retention indices (SUVr) were computed with respect to pontine, cerebellar, and composite reference regions. Several textural and shape features were extracted then combined using a support vector machine (SVM) to build a predictive model of AD conversion. Diagnostic and prognostic performance was evaluated using ROC analysis and survival analysis with the Cox proportional hazard model. The three SUVr and all the tested features effectively discriminated AD subjects in cross-sectional analysis (all p < 0.001). In longitudinal analysis, the variables with the highest prognostic value were composite SUVr (AUC 0.86; accuracy 81%), skewness (0.87; 83%), local minima (0.85; 79%), Geary's index (0.86; 81%), gradient norm maximal argument (0.83; 82%), and the SVM model (0.91; 86%). The adjusted hazard ratio for AD conversion was 5.5 for the SVM model, compared with 4.0, 2.6, and 3.8 for cerebellar, pontine and composite SUVr (all p < 0.001), indicating that appropriate amyloid textural and shape features predict conversion to AD with at least as good accuracy as classical SUVr.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Múnera, Héctor A., E-mail: hmunera@hotmail.com; Retired professor, Department of Physics, Universidad Nacional de Colombia, Bogotá, Colombia, South America
2016-07-07
It is postulated that there exists a fundamental energy-like fluid, which occupies the flat three-dimensional Euclidean space that contains our universe, and obeys the two basic laws of classical physics: conservation of linear momentum, and conservation of total energy; the fluid is described by the classical wave equation (CWE), which was Schrödinger’s first candidate to develop his quantum theory. Novel solutions for the CWE discovered twenty years ago are nonharmonic, inherently quantized, and universal in the sense of scale invariance, thus leading to quantization at all scales of the universe, from galactic clusters to the sub-quark world, and yielding amore » unified Lorentz-invariant quantum theory ab initio. Quingal solutions are isomorphic under both neo-Galilean and Lorentz transformations, and exhibit nother remarkable property: intrinsic unstability for large values of ℓ (a quantum number), thus limiting the size of each system at a given scale. Unstability and scale-invariance together lead to nested structures observed in our solar system; unstability may explain the small number of rows in the chemical periodic table, and nuclear unstability of nuclides beyond lead and bismuth. Quingal functions lend mathematical basis for Boscovich’s unified force (which is compatible with many pieces of evidence collected over the past century), and also yield a simple geometrical solution for the classical three-body problem, which is a useful model for electronic orbits in simple diatomic molecules. A testable prediction for the helicoidal-type force is suggested.« less
Chakrabarti, A; Zhang, K; Aruva, M R; Cardi, C A; Opitz, A W; Wagner, N J; Thakur, M L; Wickstrom, E
2007-06-01
There is a compelling need to image pancreas cancer at an early stage. Human pancreas cancer cells display elevated levels of KRAS protein due to high copy numbers of KRAS mRNA, and elevated levels of insulin-like growth factor 1 receptor (IGF1R) due to overexpression of IGF1R mRNA. Therefore we hypothesized that pancreas cancer could be detected in vivo with a single probe that targets both KRAS mRNA and IGF1R. Because positron emission tomography (PET) is a sensitive imaging technique, we designed a probe incorporating the positron-emitting nuclide (64)Cu. The KRAS-specific hybridization probe consisted of 1,4,7-tris(carboxymethylaza)cyclododecane-10-aza-acetyl (DO3A) on the N-terminus of a peptide nucleic acid (PNA) hybridization sequence (GCCATCAGCTCC) linked to a cyclized IGF1 peptide analog (d-Cys-Ser-Lys-Cys) on the C-terminus, for IGF1R-mediated endocytosis. A series of such KRAS radiohybridization probes with 0, 1, 2 or 3 mismatches to KRAS G12D mRNA, including exact matches to wild type KRAS mRNA and KRAS G12V mRNA, along with a double d(Ala) replacement IGF1 peptide control, were assembled by continuous solid phase synthesis. To test the hypothesis that KRAS-IGF1 dual probes could specifically image KRAS mRNA expression noninvasively in human IGF1R-overexpressing AsPC1 pancreas cancer xenografts in immunocompromised mice, [(64)Cu]PNA radiohybridization probes and controls were administered by tail vein. The [(64)Cu]KRAS-IGF1 radiohybridization probe yielded strong tumor contrast in PET images, 8.6 +/- 1.4-fold more intense in the center of human pancreas cancer xenografts than in the contralateral muscle at 4 h post-injection. Control experiments with single base KRASmismatches, an IGF1 peptide mismatch, and a breast cancer xenograft lacking KRAS activation yielded weak tumor contrast images. These experiments are consistent with our hypothesis for noninvasive PET imaging of KRAS oncogene expression in pancreas cancer xenografts. Imaging oncogene mRNAs with radiolabel-PNA-peptide nanoparticles might provide specific genetic characterization of preinvasive and invasive pancreas cancers for staging and choice of therapy.
NASA Astrophysics Data System (ADS)
Atanasov, D.; Ascher, P.; Blaum, K.; Cakirli, R. B.; Cocolios, T. E.; George, S.; Goriely, S.; Herfurth, F.; Janka, H.-T.; Just, O.; Kowalska, M.; Kreim, S.; Kisler, D.; Litvinov, Yu. A.; Lunney, D.; Manea, V.; Neidherr, D.; Rosenbusch, M.; Schweikhard, L.; Welker, A.; Wienholtz, F.; Wolf, R. N.; Zuber, K.
2015-12-01
Masses adjacent to the classical waiting-point nuclide 130Cd have been measured by using the Penning-trap spectrometer ISOLTRAP at ISOLDE/CERN. We find a significant deviation of over 400 keV from earlier values evaluated by using nuclear beta-decay data. The new measurements show the reduction of the N =82 shell gap below the doubly magic 132Sn. The nucleosynthesis associated with the ejected wind from type-II supernovae as well as from compact object binary mergers is studied, by using state-of-the-art hydrodynamic simulations. We find a consistent and direct impact of the newly measured masses on the calculated abundances in the A =128 - 132 region and a reduction of the uncertainties from the precision mass input data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brantley, P S
2006-09-27
We describe an asymptotic analysis of the coupled nonlinear system of equations describing time-dependent three-dimensional monoenergetic neutron transport and isotopic depletion and radioactive decay. The classic asymptotic diffusion scaling of Larsen and Keller [1], along with a consistent small scaling of the terms describing the radioactive decay of isotopes, is applied to this coupled nonlinear system of equations in a medium of specified initial isotopic composition. The analysis demonstrates that to leading order the neutron transport equation limits to the standard time-dependent neutron diffusion equation with macroscopic cross sections whose number densities are determined by the standard system of ordinarymore » differential equations, the so-called Bateman equations, describing the temporal evolution of the nuclide number densities.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reich C. W.; Reich,C.W.
2012-01-01
The experimental results from the various reaction and radioactive decay studies leading to nuclides in the A = 159 mass chain have been reviewed. Nuclides ranging from Pm (Z = 61) through Os (Z = 74) are included. These data are summarized and presented, together with adopted level schemes and properties. This work supersedes the previous evaluation of the data on these nuclides (2003He11).
Cosmogenic nuclide budgeting of floodplain sediment transfer
NASA Astrophysics Data System (ADS)
Wittmann, H.; von Blanckenburg, F.
2009-08-01
Cosmogenic nuclides produced in quartz may either decay or accumulate while sediment is moved through a river basin. A change in nuclide concentration resulting from storage in a floodplain is potentially important in large drainage basins in which sediment is prone to repeated burial and remobilization as a river migrates through its floodplain. We have modeled depth- and time-dependent cosmogenic nuclide concentration changes for 10Be, 26Al, and 14C during sediment storage and mixing in various active floodplain settings ranging from confined, shallow rivers with small floodplains to foreland-basin scale floodplains traversed by deep rivers. Floodplain storage time, estimated from channel migration rates, ranges from 0.4 kyr for the Beni River basin (Bolivia) to 7 kyr for the Amazon River basin, while floodplain storage depth, estimated from channel depth, ranges from 1 to 25 m. For all modeled active floodplain settings, the long-lived nuclides 10Be and 26Al show neither significant increase in nuclide concentration from irradiation nor decrease from decay. We predict a hypothetical response time after which changes in 10Be or 26Al concentrations become analytically resolvable. This interval ranges from 0.07 to 2 Myr and exceeds in all cases the typical residence time of sediment in a floodplain. Due to the much shorter half life of 14C, nuclide concentrations modeled for the in situ-produced variety of this nuclide are, however, sensitive to floodplain storage on residence times of < 20 kyr. The cosmogenic nuclide composition of old deposits in currently inactive floodplains that have been isolated for periods of millions of years from the river that once deposited them is predicted to either increase or decrease in 10Be and 26Al concentration, depending on the depositional depth. These conditions can be evaluated using the 26Al/ 10Be ratio that readily discloses the depth and duration of storage. We illustrate these models with examples from the Amazon basin. As predicted, modern bedload collected from an Amazon tributary, the Bolivian Beni River, shows no systematic change in nuclide concentration as sediment is moved through 500 km of floodplain by river meandering. In contrast, in the central Amazon floodplain currently untouched by the modern river system, low 26Al/ 10Be ratios account for minimum burial depths of 5 to 10 m for a duration of > 5 Myr. The important result of this analysis is that in all likely cases of active floodplains, cosmogenic 10Be and 26Al concentrations remain virtually unchanged over the interval sediment usually spends in the basin. Thus, spatially-averaged denudation rates of the sediment-producing area can be inferred throughout the entire basin, provided that nuclide production rates are scaled for the altitudes of the sediment-producing area only, because floodplain storage does not modify nuclide concentrations introduced from the sediment source area.
Solle, Alexander; Wanke, Carsten; Geworski, Lilli
2017-03-01
Ga-68-labeled radiotracers, particularly used for the detection of neuroendocrine tumors by means of Ga-68-DOTA-TATE or -DOTA-TOC or for the diagnosis of prostate cancer by means of Ga-68-labeled antigens (Ga 68-PSMA), become increasingly important. In addition to the high sensitivity and specificity of these radiopharmaceuticals, the short-lived radionuclide Ga-68 offers almost ideal nuclear characteristics for use in PET. Ga-68 is obtained from a germanium-gallium-generator system, so that the availability of Ga-68-labeled radiotracers is independent of an on-site-cyclotron regardless of the short half-life of Ga-68 of about 68minutes. Regarding the disposal of the radioactively contaminated waste from the preparation of the radiopharmaceutical, the eluted Ga-68 has to be considered to be additionally contaminated with its parent nuclide Ge-68. Due to this production-related impurity in combination with the short half-life of Ga-68, the radioactive waste has to be considered to be contaminated with Ge-68 and Ga-68 in radioactive equilibrium (hereafter referred to as Ge-68+). As there are no clearance levels for Ge-68+ given in the German Radiation Protection Ordinance, this work presents a method to calculate the missing value basing on a recommendation of the German Radiation Protection Commission in combination with simple geometric models of practical radiation protection. Regarding the relevant exposure scenarios, a limit value for the unrestricted clearance of Ge-68+ of 0.4 Bq/g was determined. Copyright © 2016. Published by Elsevier GmbH.
NASA Astrophysics Data System (ADS)
Lim, Hongki; Dewaraja, Yuni K.; Fessler, Jeffrey A.
2018-02-01
Most existing PET image reconstruction methods impose a nonnegativity constraint in the image domain that is natural physically, but can lead to biased reconstructions. This bias is particularly problematic for Y-90 PET because of the low probability positron production and high random coincidence fraction. This paper investigates a new PET reconstruction formulation that enforces nonnegativity of the projections instead of the voxel values. This formulation allows some negative voxel values, thereby potentially reducing bias. Unlike the previously reported NEG-ML approach that modifies the Poisson log-likelihood to allow negative values, the new formulation retains the classical Poisson statistical model. To relax the non-negativity constraint embedded in the standard methods for PET reconstruction, we used an alternating direction method of multipliers (ADMM). Because choice of ADMM parameters can greatly influence convergence rate, we applied an automatic parameter selection method to improve the convergence speed. We investigated the methods using lung to liver slices of XCAT phantom. We simulated low true coincidence count-rates with high random fractions corresponding to the typical values from patient imaging in Y-90 microsphere radioembolization. We compared our new methods with standard reconstruction algorithms and NEG-ML and a regularized version thereof. Both our new method and NEG-ML allow more accurate quantification in all volumes of interest while yielding lower noise than the standard method. The performance of NEG-ML can degrade when its user-defined parameter is tuned poorly, while the proposed algorithm is robust to any count level without requiring parameter tuning.
Nuclear Data Sheets for A = 68
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCutchan, E. A.
2012-07-01
The experimental results from the various reaction and radioactive decay studies leading to nuclides in the A = 68 mass chain have been reviewed. Nuclides ranging from Cr (Z = 24) to Br (Z = 35) are included. For these nuclei, level and decay schemes, as well as tables of nuclear properties, are given. This work supersedes the previous evaluation of the data on these nuclides (2002Bu29).
Claerhout, B; DeMoor, G J E
2005-03-01
Privacy includes the right of individuals and organisations to determine for themselves when, how and to what extent information about them is communicated to others. The growing need of managing large amounts of both clinical and genetic data raises important legal and ethical challenges. This paper introduces some of the privacy-protection problems related to classical and genomic medicine, and highlights the relevance of trusted third parties and of privacy-enhancing techniques (PETs) in the context of data collection, e.g., for research. Practical approaches based on two pseudonymisation models, for both batch data collection and interactive data storage, are presented. The actual application of the described techniques today proves the possible benefits for medicine that innovative privacy-enhancing techniques can provide. Technical PET solutions can unlock valuable data sources, otherwise not available.
NASA Astrophysics Data System (ADS)
Baker, C. W.
1984-06-01
The determination of some of the naturally-occurring, alpha-emitting radionuclides in marine environmental materials, is of interest for several reasons. Radium and radon nuclides are potentially useful as oceanographic tracers. Lead and thorium nuclides may be used to study sedimentation rates, mixing processes and bioturbation in sediments. Radium and polonium nuclides are incorporated into food chains and the data may provide a perspective against which to assess the significance, for marine organisms, of exposure to radiation in a marine radioactive waste disposal situation. This paper discusses the manner in which samples are taken, and the radiochemical methods which have been employed to measure the nuclides, together with some data produced.
NASA Astrophysics Data System (ADS)
Miura, Hitoshi
The development of compact separation and recovery methods using selective ion-exchange techniques is very important for the reprocessing and high-level liquid wastes (HLLWs) treatment in the nuclear backend field. The selective nuclide separation techniques are effective for the volume reduction of wastes and the utilization of valuable nuclides, and expected for the construction of advanced nuclear fuel cycle system and the rationalization of waste treatment. In order to accomplish the selective nuclide separation, the design and synthesis of novel adsorbents are essential for the development of compact and precise separation processes. The present paper deals with the preparation of highly functional and selective hybrid microcapsules enclosing nano-adsorbents in the alginate gel polymer matrices by sol-gel methods, their characterization and the clarification of selective adsorption properties by batch and column methods. The selective separation of Cs, Pd and Re in real HLLW was further accomplished by using novel microcapsules, and an advanced nuclide separation system was proposed by the combination of selective processes using microcapsules.
Nuclear Data Sheets for A = 34
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nica N.; Nica,N.; Singh,B.
2012-07-01
Nuclear spectroscopic information for experimentally investigated nuclides of mass 34 (Ne, Na, Mg, Al, Si, P, S, Cl, Ar, K, Ca) has been evaluated. The principal sources of the Adopted Levels presented for nuclides close to the stability line are Endt's evaluations (1990En08, 1978En02). The data sets for reactions and decays, including all available gamma-ray data, are based mostly on the original literature. There are no data available for the excited states in {sup 34}Ne and {sup 34}Na. The existence of the {sup 34}K and {sup 34}Ca nuclides has been searched and reported in a secondary publication but no evidencemore » was found for their detection. Both nuclides are possible candidates for one or two-proton emission. Only upper limits of half-lives have been proposed based on expected cross sections. Decay schemes for the {beta} decays of {sup 34}Ne, {sup 34}Na, {sup 34}Mg, and {sup 34}Si are not known. Very little information is available for {beta}-delayed neutron decays of {sup 35}Na, {sup 35}Mg and {sup 35}Si which lead to population of levels in A = 34 nuclides. Neutron-rich nuclides in this mass region are relevant to 'island of inversion'.« less
Neogene basin infilling from cosmogenic nuclides (10Be and 21Ne) in Atacama, Chile
NASA Astrophysics Data System (ADS)
Sanchez, Caroline; Regard, Vincent; Carretier, Sébastien; Riquelme, Rodrigo; Blard, Pierre-Henri; Campos, Eduardo; Brichau, Stéphanie; Lupker, Marteen; Hérail, Gérard
2017-04-01
In the hyperarid Atacama Desert, northern Chile, Neogene sediments host copper rich layers (exotic supergene mineralization). Current mines are excavated into relatively thin (<200-300 m) Neogene basins whose infilling chronology is poorly constrained. We took advantage of one of these mining pits, and sampled for 10Be and 21Ne cosmogenic nuclide dosing. These cosmogenic nuclides help constraining the infilling chronology. Indeed, basin sediments were deposited with a cosmogenic nuclide content acquired on hillslopes. Then within the basin, cosmogenic nuclide concentrations evolved through the competing production (quickly decreasing with depth) and disintegration (not for 21Ne). Sampling depths are at ˜100 m and at ˜50 m below the desert surface. First, 21Ne gives lower boundaries for upstream erosion rates or local sedimentation rate. These bounds are between 2 and 10 m/Ma, which is quite important for the area. The ratio between the two cosmogenic nuclides indicate a maximum burial age of 12 Ma (minimal erosion rate of 15 m/Ma) and is surprisingly similar from bottom to top, indicating a probable rapid infilling. We finally processed a Monte-Carlo inversion. This inversion helps taking into account the post-deposition muonic production of cosmogenic nuclides. Inversion results is dependent on the muonic production scheme. Interestingly, the similarity in concentrations from bottom to top pleads for quite low production at depth. Our data finally indicates a quick infilling between 12.5 and 10 Ma BP accounting for ˜100 m of deposition (minimum sedimentation rate of 40 m/Ma).
Erosion of mountain plateaus along Sognefjord, Norway, constrained by cosmogenic nuclides
NASA Astrophysics Data System (ADS)
Andersen, Jane Lund; Egholm, David L.; Knudsen, Mads F.; Linge, Henriette; Jansen, John D.
2016-04-01
Norway is famous for its deeply incised, steep-sided fjords, carved out by glacial erosion. The high relief of the fjords stands in contrast to the extensive areas of relatively low relief found between the fjords. The origin and development of these low-relief areas remain debated. The classical interpretation relates them to a Mesozoic peneplanation surface, uplifted to the current high elevation in the early Cenozoic (e.g. Nesje, 1994). The validity of this interpretation has, however, been repeatedly questioned in recent times (e.g. Nielsen et al. 2009, Steer et al. 2012). Recent studies point instead to a significant impact of glacial and periglacial erosion processes on the long-term development of the low-relief surfaces (Egholm et al. 2015). Here, we present a large new dataset of in-situ produced cosmogenic 10Be and 26Al in bedrock and boulders from the high, flat summit surfaces along a transect from the coast to the inner parts of Sognefjorden in Norway. Our results indicate substantial glacial modification of the sampled low-relief surfaces within the last 50 ka. Close to the coast, at an elevation of around 700 meters, the cosmogenic nuclide signal was reset around the Younger Dryas due to extensive glacial erosion. Regarding the higher surfaces further inland, our results indicate a maximum cosmogenic nuclide inheritance of 20-30 ka prior to the last deglaciation. We do not find any signs of exceptional longevity of the low-relief landscape. In contrast, our results indicate that the low-relief areas were continuously eroded by glacial and periglacial processes in the Quaternary. Nesje & Whillans. Erosion of Sognefjord, Norway. Geomorphology 9(1), 33-45, 1994. Nielsen et al. The evolution of western Scandinavian topography: a review of Neogene uplift versus the ICE (isostasy-climate-erosion) hypothesis. Journal of Geodynamics 47(2), 72-95, 2009. Steer et al. Bimodal Plio-Quaternary glacial erosion of fjords and low-relief surfaces in Scandinavia. Nature Geoscience 5(9), 635-639, 2012. Egholm et al. The periglacial engine of mountain erosion - Part 2: Modelling large-scale landscape evolution. Earth Surface Dynamics 3(4), 463-482, 2015.
Bayesian estimation of a source term of radiation release with approximately known nuclide ratios
NASA Astrophysics Data System (ADS)
Tichý, Ondřej; Šmídl, Václav; Hofman, Radek
2016-04-01
We are concerned with estimation of a source term in case of an accidental release from a known location, e.g. a power plant. Usually, the source term of an accidental release of radiation comprises of a mixture of nuclide. The gamma dose rate measurements do not provide a direct information on the source term composition. However, physical properties of respective nuclide (deposition properties, decay half-life) can be used when uncertain information on nuclide ratios is available, e.g. from known reactor inventory. The proposed method is based on linear inverse model where the observation vector y arise as a linear combination y = Mx of a source-receptor-sensitivity (SRS) matrix M and the source term x. The task is to estimate the unknown source term x. The problem is ill-conditioned and further regularization is needed to obtain a reasonable solution. In this contribution, we assume that nuclide ratios of the release is known with some degree of uncertainty. This knowledge is used to form the prior covariance matrix of the source term x. Due to uncertainty in the ratios the diagonal elements of the covariance matrix are considered to be unknown. Positivity of the source term estimate is guaranteed by using multivariate truncated Gaussian distribution. Following Bayesian approach, we estimate all parameters of the model from the data so that y, M, and known ratios are the only inputs of the method. Since the inference of the model is intractable, we follow the Variational Bayes method yielding an iterative algorithm for estimation of all model parameters. Performance of the method is studied on simulated 6 hour power plant release where 3 nuclide are released and 2 nuclide ratios are approximately known. The comparison with method with unknown nuclide ratios will be given to prove the usefulness of the proposed approach. This research is supported by EEA/Norwegian Financial Mechanism under project MSMT-28477/2014 Source-Term Determination of Radionuclide Releases by Inverse Atmospheric Dispersion Modelling (STRADI).
Nuclear Data Sheets for A = 161
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reich C. W.; Reich C.W.
2011-10-01
The experimental results from the various reaction and radioactive decay studies leading to nuclides in the A = 161 mass chain have been reviewed. Nuclides ranging from Sm (Z = 62) through Os (Z = 76) are included, with Os being a new entry based on a recently reported study. These data are summarized and presented, together with adopted level schemes and properties. This work supersedes the previous evaluation (2000Re14) of the data on these nuclides.
DOE Office of Scientific and Technical Information (OSTI.GOV)
George W. Kabalka
The research program was directed at the use of functionalized organometallic reagents that would rapidly react with radiolabeled agents generated by a medical cyclotron or reactor. The radioisotopes included fluorine-18, oxgygen-15, nitrogen-13, carbon-11 and iodine-123; all short lived nuclides of importantce in nuclear medicine imaging studies utilizing emission tomography techniques. The early studies led to the development of extensive new isotope incorporation chemistry. These studies validated the feasibility of using reactive intermediates, such as the organoboranes, and acted as a catalyst for others to investigate organometallic agents based on mercury, tin, and silicon. A large number of radiolabeling techniques andmore » radiopharmaceuticals were developed. These included agents for use in oncology, neurology, and metabolism. The research resulted in the generation of one hundred and one journal articles, eighty seven refereed published abstracts and forty one invited lectures. Thirteen postdoctoral students, fourteen graduate students, and twenty eight undergraduate students were trained in the scientific aspects of nuclear medicine imaging under the asupices of this grant.« less
Radchenko, V; Meyer, C A L; Engle, J W; Naranjo, C M; Unc, G A; Mastren, T; Brugh, M; Birnbaum, E R; John, K D; Nortier, F M; Fassbender, M E
2016-12-16
Scandium-44g (half-life 3.97h [1]) shows promise for positron emission tomography (PET) imaging of longer biological processes than that of the current gold standard, 18 F, due to its favorable decay parameters. One source of 44g Sc is the long-lived parent nuclide 44 Ti (half-life 60.0 a). A 44 Ti/ 44g Sc generator would have the ability to provide radionuclidically pure 44g Sc on a daily basis. The production of 44 Ti via the 45 Sc(p,2n) reaction requires high proton beam currents and long irradiation times. Recovery and purification of no-carrier added (nca) 44 Ti from scandium metal targets involves complex separation chemistry. In this study, separation systems based on solid phase extraction chromatography were investigated, including branched diglycolamide (BDGA) resin and hydroxamate based ZR resin. Results indicate that ZR resin in HCl media represents an effective 44 Ti/ 44g Sc separation system. Copyright © 2016 Elsevier B.V. All rights reserved.
Radchenko, Valery; Meyer, Catherine Anne Louise; Engle, Jonathan Ward; ...
2016-11-24
Scandium-44 g (half-life 3.97 h) shows promise for positron emission tomography (PET) imaging of longer biological processes than that of the current gold standard, 18F, due to its favorable decay parameters. One source of 44gSc is the long-lived parent nuclide 44Ti (half-life 60.0 a). A 44Ti/ 44gSc generator would have the ability to provide radionuclidically pure 44gSc on a daily basis. The production of 44Ti via the 45Sc(p,2n) reaction requires high proton beam currents and long irradiation times. Recovery and purification of no-carrier added (nca) 44Ti from scandium metal targets involves complex separation chemistry. In this study, separation systems basedmore » on solid phase extraction chromatography were investigated, including branched diglycolamide (BDGA) resin and hydroxamate based ZR resin. Lastly, results indicate that ZR resin in HCl media represents an effective 44Ti/ 44gSc separation system.« less
NASA Astrophysics Data System (ADS)
Lorenzi, Marco; Simpson, Ivor J.; Mendelson, Alex F.; Vos, Sjoerd B.; Cardoso, M. Jorge; Modat, Marc; Schott, Jonathan M.; Ourselin, Sebastien
2016-04-01
The joint analysis of brain atrophy measured with magnetic resonance imaging (MRI) and hypometabolism measured with positron emission tomography with fluorodeoxyglucose (FDG-PET) is of primary importance in developing models of pathological changes in Alzheimer’s disease (AD). Most of the current multimodal analyses in AD assume a local (spatially overlapping) relationship between MR and FDG-PET intensities. However, it is well known that atrophy and hypometabolism are prominent in different anatomical areas. The aim of this work is to describe the relationship between atrophy and hypometabolism by means of a data-driven statistical model of non-overlapping intensity correlations. For this purpose, FDG-PET and MRI signals are jointly analyzed through a computationally tractable formulation of partial least squares regression (PLSR). The PLSR model is estimated and validated on a large clinical cohort of 1049 individuals from the ADNI dataset. Results show that the proposed non-local analysis outperforms classical local approaches in terms of predictive accuracy while providing a plausible description of disease dynamics: early AD is characterised by non-overlapping temporal atrophy and temporo-parietal hypometabolism, while the later disease stages show overlapping brain atrophy and hypometabolism spread in temporal, parietal and cortical areas.
NASA Astrophysics Data System (ADS)
Ma, Y.; Zhang, H.; Wang, W.; Wu, Y.; Pang, J.; Zheng, D.; Li, D.
2015-12-01
Chronology studies for the Cenozoic sedimentary strata based on the magnetostratigraphy cannot afford the unique chronological sequences in the absence of absolute ages from biostratigraphy or volcanic ash chronology. In situ-produced cosmogenic nuclides provide a powerful tool for the sediment dating based on the time-dependent concentration ratio of two nuclides, which are produced in the same mineral but with different half-lives. Thereinto, 10Be-26Al is the most widely used nuclide pairs, of which the available dating range spans the Plio-Pleistocene. But the coupling of 10Be with the stable nuclide 21Ne would significantly improve the burial dating range up to the middle Miocene, which is promising in revolutionizing the chronology study for the Late Cenozoic terrestrial sedimentary sequences. We have applied 10Be-21Ne pair for dating the middle Miocene sediments of the Hongliu Valley in southern Ningxia basin. Two major features of the sediments are involved in our study: (1) sediments originated from the steady erosion of the source area, and (2) the burial depth of our sample after deposition is time dependent due to the gradual accumulation of sediments into basin. The post-burial nuclide production is estimated to be less than 3%, including the contribution by muon interactions, of the total nuclide concentrations measured in our sample. Our 10Be-21Ne analysis demonstrates the age of the burial sample is 12.4(+0.6/-0.4) Ma, and the erosion rate at the source area is 0.26±0.01 cm ka-1. The sample's burial age is consistent with the age constraint set by the Hongliugou Formation (16.7-5.4 Ma) which we collected the sample in. Vertebrate fossils of Platybelodon tongxinensis with an age between 12 and 15 Ma exhumated along with our sample further verifies the reliability of our dating results for the middle Miocene sediments.This study has shown the improved age range of cosmogenic-nuclide burial dating method by incorporating the stable nuclide 21Ne, and has established the feasibility of 10Be-21Ne pair in chronology studies for the Cenozoic sedimentary strata.
EML Gamma Spectrometry Data Evaluation Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Decker, Karin M.
1998-02-28
This report represents the results of the analyses for the second EML Gamma Spectrometry Data Evaluation Program (August 1997). A calibration spectrum, a background spectrum and three sample spectra were included for each software format as part of the evaluation. The calibration spectrum contained nuclides covering the range from 59.5 keV to 1836 keV. The participants were told fallout and fission product nuclides as well as naturally occurring nuclides could be present. The samples were designed to test the detection and quantification of very low levels of nuclides and the ability of the software and user to properly resolve multiplets.more » The participants were asked to report values and uncertainties as Becquerel per sample with no decay correction. Twenty-nine sets of results were reported from a total of 70 laboratories who received the spectra. The percentage of the results within 1 F of the expected value was 76, 67, and 55 for samples 1, 2, and 3, respectively. From all three samples, 12% of the results were more than 3 F from the expected value. Sixty-two nuclides out of a total of 580 expected results were not reported for the three samples. Sixty percent of these false negatives were due to nuclides which were present at the minimum detectable activity level. There were 53 false positives reported with 60% of the responses due to problems with background subtraction. The results indicate that the Program is beneficial to the participating laboratories in that it provides them with analysis problems that are difficult to create with spiked samples due to the unavailability of many nuclides and the short half-lives of others. EML will continue its annual distribution, the third is to be held in March 1999.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holden, N.E., E-mail: holden@bnl.gov
Isotopes and nuclides are important in our everyday life. The general public and most students are never exposed to the concepts of stable and radioactive isotopes/nuclides. The National Nuclear Data Center (NNDC) is involved in an international project to develop a Periodic Table of the Isotopes for the educational community to illustrate the importance of isotopes and nuclides in understanding the world around us. This effort should aid teachers in introducing these concepts to students from the high school to the graduate school level.
WebCN: A web-based computation tool for in situ-produced cosmogenic nuclides
NASA Astrophysics Data System (ADS)
Ma, Xiuzeng; Li, Yingkui; Bourgeois, Mike; Caffee, Marc; Elmore, David; Granger, Darryl; Muzikar, Paul; Smith, Preston
2007-06-01
Cosmogenic nuclide techniques are increasingly being utilized in geoscience research. For this it is critical to establish an effective, easily accessible and well defined tool for cosmogenic nuclide computations. We have been developing a web-based tool (WebCN) to calculate surface exposure ages and erosion rates based on the nuclide concentrations measured by the accelerator mass spectrometry. WebCN for 10Be and 26Al has been finished and published at http://www.physics.purdue.edu/primelab/for_users/rockage.html. WebCN for 36Cl is under construction. WebCN is designed as a three-tier client/server model and uses the open source PostgreSQL for the database management and PHP for the interface design and calculations. On the client side, an internet browser and Microsoft Access are used as application interfaces to access the system. Open Database Connectivity is used to link PostgreSQL and Microsoft Access. WebCN accounts for both spatial and temporal distributions of the cosmic ray flux to calculate the production rates of in situ-produced cosmogenic nuclides at the Earth's surface.
Yamato, A; Miyagawa, N; Miyanaga, N
1984-07-01
To investigate behaviour of 95Zr, 95Nb in the marine environment, various samples have been collected and measured by means of Ge(Li) gamma-ray spectrometry and/or radiochemical analysis during a period from 1974 to 1982 at coastal area of Tokai-mura, Ibaraki prefecture. Concentration of the nuclides in seaweeds increased remarkably after atmospheric nuclear detonation by P.R. of China, and the activity ratio between the nuclides changed by time was not fit well by the transient decay equation. Concentration variation in sea water was smaller than that in sea weeds, and the minimum change in sea sediment. Increase of concentration in these environmental samples was observed in chronological order of sea water, sea weeds then sediment after detonations, suggesting that the uptake of the nuclides by these sea weeds from sea water is faster than that via root. Observed concentration factors on the nuclides by sea weeds were calculated from the observed concentrations in sea water and sea weeds. Maximum values on 95Zr and 95Nb were 2110, 2150, respectively for Ecklonia cava and Eisenia bicyclis.
A rare cause of Cushing's syndrome: an ACTH-secreting phaeochromocytoma
Folkestad, Lars; Andersen, Marianne Skovsager; Nielsen, Anne Lerberg; Glintborg, Dorte
2014-01-01
Excess glucocorticoid levels cause Cushing's syndrome (CS) and may be due to pituitary, adrenal or ectopic tumours. Adrenocorticotropic hormone (ACTH) levels are useful in identifying adrenal tumours. In rare cases, ACTH-producing phaeochromocytomas are the cause of CS. We present two cases of ACTH-secreting phaeochromocytoma as the underlying cause of CS. In both cases, female patients presented with the classical clinical signs of CS and an adrenal mass. High ACTH levels raised the suspicion of an ACTH-secreting phaeochromocytoma. The diagnosis was confirmed by urinary catecholamine levels and positive fluorine-18-L-dihydroxyphenylalanine (18F-DOPA) positron emission tomography (PET) CT (Case 1) and fluorodeoxyglucose PET-CT (Case 2). Both patients were treated with an α-blocker prior to surgical intervention. The two cases underline the importance of thorough diagnostic workup in patients with CS. An ACTH-secreting phaeochromocytoma should be checked for in patients with an adrenal mass and elevated ACTH levels. PMID:25297883
Cosmogenic-nuclide production by primary cosmic-ray protons
NASA Technical Reports Server (NTRS)
Reedy, R. C.
1985-01-01
The production rates of cosmogenic nuclides were calculated for the primary protons in the galactic and solar cosmic rays. At 1 AU, the long-term average fluxes of solar protons usually produce many more atoms of cosmogenic nuclide than the primary protons in the galactic cosmic rays (GCR). Because the particle fluxes inside meteorites and other large objects in space include many secondary neutrons, the production rates and ratios inside large objects are often very different from those by just the primary GCR protons. It is possible to determine if a small object, was small in space or broken from a meteorite. Because heliospherical modulation and other interactions change the GCR particle spectrum, the production of cosmogenic nuclides by the GCR particles outside the heliosphere will be different from that by modulated GCR primaries.
Kinetics analysis and quantitative calculations for the successive radioactive decay process
NASA Astrophysics Data System (ADS)
Zhou, Zhiping; Yan, Deyue; Zhao, Yuliang; Chai, Zhifang
2015-01-01
The general radioactive decay kinetics equations with branching were developed and the analytical solutions were derived by Laplace transform method. The time dependence of all the nuclide concentrations can be easily obtained by applying the equations to any known radioactive decay series. Taking the example of thorium radioactive decay series, the concentration evolution over time of various nuclide members in the family has been given by the quantitative numerical calculations with a computer. The method can be applied to the quantitative prediction and analysis for the daughter nuclides in the successive decay with branching of the complicated radioactive processes, such as the natural radioactive decay series, nuclear reactor, nuclear waste disposal, nuclear spallation, synthesis and identification of superheavy nuclides, radioactive ion beam physics and chemistry, etc.
[Etiologies of cerebral palsy and classical treatment possibilities].
Maurer, Ute
2002-01-01
Cerebral palsy is a non-progressive disorder of the developing brain with different etiologies in the pre-, peri- or postnatal period. The most important of these diseases is cystic periventricular leukomalacia (PVL), followed by intra- and periventricular hemorrhage, hypoxic-ischemic encephalopathy, vascular disorders, infections or brain malformations. The underlying cause is always a damage of the first motor neuron. Prevalence of cerebral palsy in Europe is 2-3 per 1000 live births with a broad spectrum in different birth weight groups. Our own data concerning only pre-term infants in the NICU with birth weight below 1500 g (VLBW) are between 10%-20%. Established classical treatment methods include physiotherapy (Bobath, Vojta, Hippotherapy), methods of speech and occupational therapists (Castillo-Morales, Sensory Integration) and other therapeutical concepts (Petö, Affolter, Frostig).
Pobric, Gorana; Jefferies, Elizabeth; Ralph, Matthew A. Lambon
2007-01-01
Studies of semantic dementia and PET neuroimaging investigations suggest that the anterior temporal lobes (ATL) are a critical substrate for semantic representation. In stark contrast, classical neurological models of comprehension do not include ATL, and likewise functional MRI studies often fail to show activations in the ATL, reinforcing the classical view. Using a novel application of low-frequency, repetitive transcranial magnetic stimulation (rTMS) over the ATL, we demonstrate that the behavioral pattern of semantic dementia can be mirrored in neurologically intact participants: Specifically, we show that temporary disruption to neural processing in the ATL produces a selective semantic impairment leading to significant slowing in both picture naming and word comprehension but not to other equally demanding, nonsemantic cognitive tasks. PMID:18056637
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holden, N. E.
We found that isotopes and nuclides are important in our everyday life. The general public and most students are never exposed to the concepts of stable and radioactive isotopes/nuclides. The National Nuclear Data Center (NNDC) is involved in an international project to develop a Periodic Table of the Isotopes for the educational community to illustrate the importance of isotopes and nuclides in understanding the world around us. Our effort should aid teachers in introducing these concepts to students from the high school to the graduate school level.
Simon, Quentin; Thouveny, Nicolas; Bourlès, Didier L; Valet, Jean-Pierre; Bassinot, Franck; Ménabréaz, Lucie; Guillou, Valéry; Choy, Sandrine; Beaufort, Luc
2016-11-01
Geomagnetic dipole moment variations associated with polarity reversals and excursions are expressed by large changes of the cosmogenic nuclide beryllium-10 ( 10 Be) production rates. Authigenic 10 Be/ 9 Be ratios (proxy of atmospheric 10 Be production) from oceanic cores therefore complete the classical information derived from relative paleointensity (RPI) records. This study presents new authigenic 10 Be/ 9 Be ratio results obtained from cores MD05-2920 and MD05-2930 collected in the west equatorial Pacific Ocean. Be ratios from cores MD05-2920, MD05-2930 and MD90-0961 have been stacked and averaged. Variations of the authigenic 10 Be/ 9 Be ratio are analyzed and compared with the geomagnetic dipole low series reported from global RPI stacks. The largest 10 Be overproduction episodes are related to dipole field collapses (below a threshold of 2 × 10 22 Am 2 ) associated with the Brunhes/Matuyama reversal, the Laschamp (41 ka) excursion, and the Iceland Basin event (190 ka). Other significant 10 Be production peaks are correlated to geomagnetic excursions reported in literature. The record was then calibrated by using absolute dipole moment values drawn from the Geomagia and Pint paleointensity value databases. The 10 Be-derived geomagnetic dipole moment record, independent from sedimentary paleomagnetic data, covers the Brunhes-Matuyama transition and the whole Brunhes Chron. It provides new and complementary data on the amplitude and timing of millennial-scale geomagnetic dipole moment variations and particularly on dipole moment collapses triggering polarity instabilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soukhovitski, Efrem Sh.; Chiba, Satoshi; Lee, Jeong-Yeon
2005-05-24
A coupled-channels optical model with a coupling scheme based on nuclear wave functions of the soft-rotator model was applied to analyze experimental nucleon-nucleus interaction data for even-even nuclides with mass number A=24-122. We found that all the available data (total cross sections, angular distributions of elastically and inelastically scattered nucleons, and reaction cross sections) for these nuclides can be described to a good accuracy using an optical potential having smooth dependencies of potential values, radii, and diffuseness on the mass number. The individual properties of the target nuclides are accounted for by individuality of the nuclear Hamiltonian parameters, adjusted tomore » reproduce the low-lying collective level structure, Fermi energies, and deformation parameters.« less
PET Imaging of Tumor-Associated Macrophages with 89Zr-Labeled High-Density Lipoprotein Nanoparticles
Pérez-Medina, Carlos; Tang, Jun; Abdel-Atti, Dalya; Hogstad, Brandon; Merad, Miriam; Fisher, Edward A.; Fayad, Zahi A.; Lewis, Jason S.; Mulder, Willem J.M.; Reiner, Thomas
2015-01-01
Tumor-associated macrophages (TAMs) are increasingly investigated in cancer immunology and are considered a promising target for better and tailored treatment of malignant growth. Although TAMs also have high diagnostic and prognostic value, TAM imaging still remains largely unexplored. Here, we describe the development of reconstituted high-density lipoprotein (rHDL)–facilitated TAM PET imaging in a breast cancer model. Methods Radiolabeled rHDL nanoparticles incorporating the long-lived positron-emitting nuclide 89Zr were developed using 2 different approaches. The nanoparticles were composed of phospholipids and apolipoprotein A-I (apoA-I) in a 2.5:1 weight ratio. 89Zr was complexed with deferoxamine (also known as desferrioxamine B, desferoxamine B), conjugated either to a phospholipid or to apoA-I to generate 89Zr-PL-HDL and 89Zr-AI-HDL, respectively. In vivo evaluation was performed in an orthotopic mouse model of breast cancer and included pharmacokinetic analysis, biodistribution studies, and PET imaging. Ex vivo histologic analysis of tumor tissues to assess regional distribution of 89Zr radioactivity was also performed. Fluorescent analogs of the radiolabeled agents were used to determine cell-targeting specificity using flow cytometry. Results The phospholipid- and apoA-I–labeled rHDL were produced at 79% ± 13% (n = 6) and 94% ± 6% (n = 6) radiochemical yield, respectively, with excellent radiochemical purity (>99%). Intravenous administration of both probes resulted in high tumor radioactivity accumulation (16.5 ± 2.8 and 8.6 ± 1.3 percentage injected dose per gram for apoA-I– and phospholipid-labeled rHDL, respectively) at 24 h after injection. Histologic analysis showed good colocalization of radioactivity with TAM-rich areas in tumor sections. Flow cytometry revealed high specificity of rHDL for TAMs, which had the highest uptake per cell (6.8-fold higher than tumor cells for both DiO@Zr-PL-HDL and DiO@Zr-AI-HDL) and accounted for 40.7% and 39.5% of the total cellular DiO@Zr-PL-HDL and DiO@Zr-AI-HDL in tumors, respectively. Conclusion We have developed 89Zr-labeled TAM imaging agents based on the natural nanoparticle rHDL. In an orthotopic mouse model of breast cancer, we have demonstrated their specificity for macrophages, a result that was corroborated by flow cytometry. Quantitative macrophage PET imaging with our 89Zr-rHDL imaging agents could be valuable for noninvasive monitoring of TAM immunology and targeted treatment. PMID:26112022
[Current status and potential perspectives in classical radiotherapy technology].
Dabić-Stanković, Kata M; Stanković, Jovan B; Radosević-Jelić, Ljiljana M
2004-01-01
After purchase of radiotherapy equipment in 2003, classic radiation therapy in Serbia will reach the highest world level. In order to define the highest standards in radiation technology, we analyzed the current status and potential perspectives of radiation therapy. An analysis of present situation in the USA, assumed as the most developed in the world, was done. Available data, collected in the last 3 years (equipment assortment, therapy modalities, workload and manpower) for 284 radiotherapy centers, out of potential 2050, were analyzed. Results were presented as crude percentage and matched to point current status. The analysis showed that CLINAC accelerators are the most popular (82.7%), as well as, ADAC (43.7%) and Focus (CMS) (27.4%) systems for therapy planning. Movement towards virtual simulation is evident (59.3%), although classic "simulation" is not fully eliminated from the radiotherapy chain. The most popular brachytherapy afterloader is Microselectron HDR (71%). About 64.4% centers use IMPAC communication/verification/record system that seems more open than Varis. All centers practice modern radiotherapy modalities and techniques (CPRT, IMRT, SRS/SRT, TBI, IORT, IVBHRT, HDR BHRT, etc.). CT and MRI availability is out of question, but PET is available in 3% of centers, however this percentage is rapidly growing. Up to 350 new patients per year are treated by one accelerator (about 35 pts. a day). Centers are relatively small and utilize 2-3 accelerators on average. Average FTE staffing norm is 4 radiation oncologists, 2-3 medical radiotherapy physicists, about 3 certified medical dosimetrists and about 6 radiotherapy technologists. In the past 5 years relative stagnation in classic radiotherapy has been observed. In spite of substantial investments in technology and consequent improvements, as well as wide introduction of computers in radiotherapy, radiotherapy results have not changed significantly. Vendor developement strategies do not point that this trend will change in the next 5 years. On the other hand, wide introduction of the PET in each radiotherapy chain ring (diagnostics, planning, follow-up), could improve results (local and regional control, as well as quality of patients' life).
NASA Astrophysics Data System (ADS)
Argento, D.; Reedy, R. C.; Stone, J. O.
2012-12-01
Cosmogenic nuclides have been used to develop a set of tools critical to the quantification of a wide range of geomorphic and climatic processes and events (Dunai 2010). Having reliable absolute measurement methods has had great impact on research constraining ice age extents as well as providing important climatic data via well constrained erosion rates, etc. Continuing to improve CN methods is critical for these sciences. While significant progress has been made in the last two decades to reduce uncertainties (Dunai 2010; Gosse & Phillips 2001), numerous aspects still need to be refined in order to achieve the analytic resolution desired by glaciologists and geomorphologists. In order to investigate the finer details of the radiation responsible for cosmogenic nuclide production, we have developed a physics based model which models the radiation cascade of primary and secondary cosmic-rays through the atmosphere. In this study, a Monte Carlo method radiation transport code, MCNPX, is used to model the galactic cosmic-ray (GCR) radiation impinging on the upper atmosphere. Beginning with a spectrum of high energy protons and alpha particles at the top of the atmosphere, the code tracks the primary and resulting secondary particles through a model of the Earth's atmosphere and into the lithosphere. Folding the neutron and proton flux results with energy dependent cross sections for nuclide production provides production rates for key cosmogenic nuclides (Argento et al. 2012, in press; Reedy 2012, in press). Our initial study for high latitude shows that nuclides scale at different rates for each nuclide (Argento 2012, in press). Furthermore, the attenuation length for each of these nuclide production rates increases with altitude, and again, they increase at different rates. This has the consequence of changing the production rate ratio as a function of altitude. The earth's geomagnetic field differentially filters low energy cosmic-rays by deflecting them away. This effect is strongest at the equator. This filtering reduces the total number of particles, and also biases the spectrum towards the higher energies. This effect is known to generally increase the attenuation length of production with altitude at the same time reducing the overall production rate. Our model now extends from high latitude to the equator. We expect the production rates, attenuation lengths and production ratios to also be functions of latitude. Our radiation model results are being analyzed and nuclide production rate results will be presented at the conference.
Cosmogenic Nuclides Study of Large Iron Meteorites
NASA Astrophysics Data System (ADS)
Hutzler, A.; Smith, T.; Rochette, P.; Bourles, D. L.; Leya, I.; Gattacceca, J.
2014-09-01
Six large iron meteorites were selected (Saint-Aubin, Mont-Dieu, Caille, Morasko, Agoudal, and Gebel Kamil). We measured stable and radiogenic cosmogenic nuclides, to study pre-atmospheric size, cosmic-ray exposure ages and terrestrial ages.
Reprocessing system with nuclide separation based on chromatography in hydrochloric acid solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, Tatsuya; Tachibana, Yu; Koyama, Shi-ichi
2013-07-01
We have proposed the reprocessing system with nuclide separation processes based on the chromatographic technique in the hydrochloric acid solution system. Our proposed system consists of the dissolution process, the reprocessing process, the minor actinide separation process, and nuclide separation processes. In the reprocessing and separation processes, the pyridine resin is used as a main separation media. It was confirmed that the dissolution in the hydrochloric acid solution is easily achieved by the plasma voloxidation and by the addition of oxygen peroxide into the hydrochloric acid solution.
Effects of bulk composition on production rates of cosmogenic nuclides in meteorites
NASA Technical Reports Server (NTRS)
Masarik, Jozef; Reedy, Robert C.
1993-01-01
The bulk chemical composition of meteorites has been suggested as a main factor influencing the production of cosmogenic nuclides. Numerical simulations with Los Alamos Monte Carlo production and transport codes were done for Ne-21/Ne-22 ratios and Ar-38 production rates in meteorites with a wide range of compositions. The calculations show that an enhanced flux of low-energy secondary particles in metal-rich phases is the essential key for the explanation of experimentally observed differences in nuclide production processes in various meteorite classes.
Application of the mass-spectrometer MASHA for mass-spectrometry and laser-spectroscopy
NASA Astrophysics Data System (ADS)
Rodin, A. M.; Belozerov, A. V.; Dmitriev, S. N.; Oganessian, Yu. Ts.; Sagaidak, R. N.; Salamatin, V. S.; Stepantsov, S. V.; Vanin, D. V.
2010-02-01
We report the present status of the mass-spectrometer MASHA (Mass-Analyzer of Supper Heavy Atoms) designed for determination of the masses of superheavy elements. The mass-spectrometer is connected to the U-400M cyclotron of the Flerov Laboratory for Nuclear Reactions (FLNR) JINR, Dubna. The first experiments on mass-measurements for 112 and 114 elements will be performed in the upcoming 2010. For this purpose a hot catcher, based on a graphite stopper, is constructed. The α-decay of the superheavy nuclides or spontaneous fission products will be detected with a silicon 192 strips detector. The experimental program of future investigations using the technique of a gas catcher is discussed. It should be regarded as an alternative of the classical ISOL technique. The possibilities are considered for using this mass-spectrometer for laser spectroscopy of nuclei far off-stability.
Inter-laboratory comparisons of short-lived gamma-emitting radionuclides in nuclear reactor water.
Klemola, S K
2008-01-01
Inter-laboratory comparisons of gamma-emitting nuclides in nuclear power plant coolant water have been carried out in Finland since 1994. The reactor water samples are taken and prepared by one of the two nuclear power plants and delivered to the participants. Since all the participants get their sample within just a few hours it has been possible to analyse and compare results of nuclides with half-lives shorter than 1h. The total number of short-lived nuclides is 26. All the main nuclides are regularly identified and the activities have been obtained with reasonable accuracy throughout the years. The overall deviation of the results has decreased in 13 years. The effects of true coincidence summing and discrepancies in nuclear data have been identified as potential sources of remaining discrepancies. All the participants have found this type of comparison very useful.
A heuristic statistical stopping rule for iterative reconstruction in emission tomography.
Ben Bouallègue, F; Crouzet, J F; Mariano-Goulart, D
2013-01-01
We propose a statistical stopping criterion for iterative reconstruction in emission tomography based on a heuristic statistical description of the reconstruction process. The method was assessed for MLEM reconstruction. Based on Monte-Carlo numerical simulations and using a perfectly modeled system matrix, our method was compared with classical iterative reconstruction followed by low-pass filtering in terms of Euclidian distance to the exact object, noise, and resolution. The stopping criterion was then evaluated with realistic PET data of a Hoffman brain phantom produced using the GATE platform for different count levels. The numerical experiments showed that compared with the classical method, our technique yielded significant improvement of the noise-resolution tradeoff for a wide range of counting statistics compatible with routine clinical settings. When working with realistic data, the stopping rule allowed a qualitatively and quantitatively efficient determination of the optimal image. Our method appears to give a reliable estimation of the optimal stopping point for iterative reconstruction. It should thus be of practical interest as it produces images with similar or better quality than classical post-filtered iterative reconstruction with a mastered computation time.
NASA Astrophysics Data System (ADS)
Thomas, Benjamin A.; Cuplov, Vesna; Bousse, Alexandre; Mendes, Adriana; Thielemans, Kris; Hutton, Brian F.; Erlandsson, Kjell
2016-11-01
Positron emission tomography (PET) images are degraded by a phenomenon known as the partial volume effect (PVE). Approaches have been developed to reduce PVEs, typically through the utilisation of structural information provided by other imaging modalities such as MRI or CT. These methods, known as partial volume correction (PVC) techniques, reduce PVEs by compensating for the effects of the scanner resolution, thereby improving the quantitative accuracy. The PETPVC toolbox described in this paper comprises a suite of methods, both classic and more recent approaches, for the purposes of applying PVC to PET data. Eight core PVC techniques are available. These core methods can be combined to create a total of 22 different PVC techniques. Simulated brain PET data are used to demonstrate the utility of toolbox in idealised conditions, the effects of applying PVC with mismatched point-spread function (PSF) estimates and the potential of novel hybrid PVC methods to improve the quantification of lesions. All anatomy-based PVC techniques achieve complete recovery of the PET signal in cortical grey matter (GM) when performed in idealised conditions. Applying deconvolution-based approaches results in incomplete recovery due to premature termination of the iterative process. PVC techniques are sensitive to PSF mismatch, causing a bias of up to 16.7% in GM recovery when over-estimating the PSF by 3 mm. The recovery of both GM and a simulated lesion was improved by combining two PVC techniques together. The PETPVC toolbox has been written in C++, supports Windows, Mac and Linux operating systems, is open-source and publicly available.
Caldwell, John T.; Kunz, Walter E.; Cates, Michael R.; Franks, Larry A.
1985-01-01
Simultaneous photon and neutron interrogation of samples for the quantitative determination of total fissile nuclide and total fertile nuclide material present is made possible by the use of an electron accelerator. Prompt and delayed neutrons produced from resulting induced fissions are counted using a single detection system and allow the resolution of the contributions from each interrogating flux leading in turn to the quantitative determination sought. Detection limits for .sup.239 Pu are estimated to be about 3 mg using prompt fission neutrons and about 6 mg using delayed neutrons.
Caldwell, J.T.; Kunz, W.E.; Cates, M.R.; Franks, L.A.
1982-07-07
Simultaneous photon and neutron interrogation of samples for the quantitative determination of total fissile nuclide and total fertile nuclide material present is made possible by the use of an electron accelerator. Prompt and delayed neutrons produced from resulting induced fission are counted using a single detection system and allow the resolution of the contributions from each interrogating flux leading in turn to the quantitative determination sought. Detection limits for /sup 239/Pu are estimated to be about 3 mg using prompt fission neutrons and about 6 mg using delayed neutrons.
Saito, Kimiaki; Tanihata, Isao; Fujiwara, Mamoru; Saito, Takashi; Shimoura, Susumu; Otsuka, Takaharu; Onda, Yuichi; Hoshi, Masaharu; Ikeuchi, Yoshihiro; Takahashi, Fumiaki; Kinouchi, Nobuyuki; Saegusa, Jun; Seki, Akiyuki; Takemiya, Hiroshi; Shibata, Tokushi
2015-01-01
Soil deposition density maps of gamma-ray emitting radioactive nuclides from the Fukushima Dai-ichi Nuclear Power Plant (NPP) accident were constructed on the basis of results from large-scale soil sampling. In total 10,915 soil samples were collected at 2168 locations. Gamma rays emitted from the samples were measured by Ge detectors and analyzed using a reliable unified method. The determined radioactivity was corrected to that of June 14, 2011 by considering the intrinsic decay constant of each nuclide. Finally the deposition maps were created for (134)Cs, (137)Cs, (131)I, (129m)Te and (110m)Ag. The radioactivity ratio of (134)Cs-(137)Cs was almost constant at 0.91 regardless of the locations of soil sampling. The radioactivity ratios of (131)I and (129m)Te-(137)Cs were relatively high in the regions south of the Fukushima NPP site. Effective doses for 50 y after the accident were evaluated for external and inhalation exposures due to the observed radioactive nuclides. The radiation doses from radioactive cesium were found to be much higher than those from the other radioactive nuclides. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Risner, J. M.; Wiarda, D.; Dunn, M. E.
2011-09-30
New coupled neutron-gamma cross-section libraries have been developed for use in light water reactor (LWR) shielding applications, including pressure vessel dosimetry calculations. The libraries, which were generated using Evaluated Nuclear Data File/B Version VII Release 0 (ENDF/B-VII.0), use the same fine-group and broad-group energy structures as the VITAMIN-B6 and BUGLE-96 libraries. The processing methodology used to generate both libraries is based on the methods used to develop VITAMIN-B6 and BUGLE-96 and is consistent with ANSI/ANS 6.1.2. The ENDF data were first processed into the fine-group pseudo-problem-independent VITAMIN-B7 library and then collapsed into the broad-group BUGLE-B7 library. The VITAMIN-B7 library containsmore » data for 391 nuclides. This represents a significant increase compared to the VITAMIN-B6 library, which contained data for 120 nuclides. The BUGLE-B7 library contains data for the same nuclides as BUGLE-96, and maintains the same numeric IDs for those nuclides. The broad-group data includes nuclides which are infinitely dilute and group collapsed using a concrete weighting spectrum, as well as nuclides which are self-shielded and group collapsed using weighting spectra representative of important regions of LWRs. The verification and validation of the new libraries includes a set of critical benchmark experiments, a set of regression tests that are used to evaluate multigroup crosssection libraries in the SCALE code system, and three pressure vessel dosimetry benchmarks. Results of these tests confirm that the new libraries are appropriate for use in LWR shielding analyses and meet the requirements of Regulatory Guide 1.190.« less
Behavior of cesium in municipal solid waste incineration.
Oshita, Kazuyuki; Aoki, Hiroshi; Fukutani, Satoshi; Shiota, Kenji; Fujimori, Takashi; Takaoka, Masaki
2015-05-01
As a result of the Fukushima Daiichi Nuclear Power Plant accident on March 11, 2011 in Japan radioactive nuclides, primarily (134)Cs and (137)Cs were released, contaminating municipal solid waste and sewage sludge in the area. Although stabilizing the waste and reducing its volume is an important issue differing from Chernobyl nuclear power plant accident, secondary emission of radioactive nuclides as a result of any intermediate remediation process is of concern. Unfortunately, there is little research on the behavior of radioactive nuclides during waste treatment. This study focuses on waste incineration in an effort to clarify the behavior of radioactive nuclides, specifically, refuse-derived fuel (RDF) with added (133)Cs (stable nuclide) or (134)Cs (radioactive nuclide) was incinerated in laboratory- and pilot-scale experiments. Next, thermogravimetric (TG) and differential thermal analysis (DTA) of stable Cs compounds, as well as an X-ray absorption fine structure (XAFS) analysis of Cs concentrated in the ashes were performed to validate the behavior and chemical forms of Cs during the combustion. Our results showed that at higher temperatures and at larger equivalence ratios, (133)Cs was distributed to the bottom ash at lower concentration, and the influence of the equivalence ratio was more significant at lower temperatures. (134)Cs behaved in a similar fashion as (133)Cs. We found through TG-DTA and XAFS analysis that a portion of Cs in RDF vaporizes and is transferred to fly ash where it exists as CsCl in the MSW incinerator. We conclude that Cs-contaminated municipal solid wastes could be incinerated at high temperatures resulting in a small amount of fly ash with a high concentration of radioactive Cs, and a bottom ash with low concentrations. Copyright © 2015 Elsevier Ltd. All rights reserved.
A rare cause of Cushing's syndrome: an ACTH-secreting phaeochromocytoma.
Folkestad, Lars; Andersen, Marianne Skovsager; Nielsen, Anne Lerberg; Glintborg, Dorte
2014-10-08
Excess glucocorticoid levels cause Cushing's syndrome (CS) and may be due to pituitary, adrenal or ectopic tumours. Adrenocorticotropic hormone (ACTH) levels are useful in identifying adrenal tumours. In rare cases, ACTH-producing phaeochromocytomas are the cause of CS. We present two cases of ACTH-secreting phaeochromocytoma as the underlying cause of CS. In both cases, female patients presented with the classical clinical signs of CS and an adrenal mass. High ACTH levels raised the suspicion of an ACTH-secreting phaeochromocytoma. The diagnosis was confirmed by urinary catecholamine levels and positive fluorine-18-L-dihydroxyphenylalanine (18F-DOPA) positron emission tomography (PET) CT (Case 1) and fluorodeoxyglucose PET-CT (Case 2). Both patients were treated with an α-blocker prior to surgical intervention. The two cases underline the importance of thorough diagnostic workup in patients with CS. An ACTH-secreting phaeochromocytoma should be checked for in patients with an adrenal mass and elevated ACTH levels. 2014 BMJ Publishing Group Ltd.
Non-radiative decay paths in rhodamines: new theoretical insights.
Savarese, Marika; Raucci, Umberto; Adamo, Carlo; Netti, Paolo A; Ciofini, Ilaria; Rega, Nadia
2014-10-14
We individuate a photoinduced electron transfer (PeT) as a quenching mechanism affecting rhodamine B photophysics in solvent. The PeT involves an electron transfer from the carboxylate group to the xanthene ring of rhodamine B. This is finely modulated by the subtle balance of coulombic and non-classical interactions between the carboxyphenyl and xanthene rings, also mediated by the solvent. We propose the use of an electronic density based index, the so called DCT index, as a new tool to assess and quantify the nature of the excited states involved in non-radiative decays near the region of their intersection. In the present case, this analysis allows us to gain insight on the interconversion process from the bright state to the dark state responsible for the quenching of rhodamine B fluorescence. Our findings encourage the use of density based indices to study the processes affecting excited state reactions that are characterized by a drastic change in the excitation nature, in order to rationalize the photophysical behavior of complex molecular systems.
Radiosyntheses using Fluorine-18: the Art and Science of Late Stage Fluorination
Cole, Erin L.; Stewart, Megan N.; Littich, Ryan; Hoareau, Raphael; Scott, Peter J. H.
2014-01-01
Positron (β+) emission tomography (PE) is a powerful, noninvasive tool for the in vivo, three-dimensional imaging of physiological structures and biochemical pathways. The continued growth of PET imaging relies on a corresponding increase in access to radiopharmaceuticals (biologically active molecules labeled with short-lived radionuclides such as fluorine-18). This unique need to incorporate the short-lived fluorine-18 atom (t1/2 = 109.77 min) as late in the synthetic pathway as possible has made development of methodologies that enable rapid and efficient late stage fluorination an area of research within its own right. In this review we describe strategies for radiolabeling with fluorine-18, including classical fluorine-18 radiochemistry and emerging techniques for late stage fluorination reactions, as well as labeling technologies such as microfluidics and solid-phase radiochemistry. The utility of fluorine-18 labeled radiopharmaceuticals is showcased through recent applications of PET imaging in the healthcare, personalized medicine and drug discovery settings. PMID:24484425
Thouveny, Nicolas; Bourlès, Didier L.; Valet, Jean‐Pierre; Bassinot, Franck; Ménabréaz, Lucie; Guillou, Valéry; Choy, Sandrine; Beaufort, Luc
2016-01-01
Abstract Geomagnetic dipole moment variations associated with polarity reversals and excursions are expressed by large changes of the cosmogenic nuclide beryllium‐10 (10Be) production rates. Authigenic 10Be/9Be ratios (proxy of atmospheric 10Be production) from oceanic cores therefore complete the classical information derived from relative paleointensity (RPI) records. This study presents new authigenic 10Be/9Be ratio results obtained from cores MD05‐2920 and MD05‐2930 collected in the west equatorial Pacific Ocean. Be ratios from cores MD05‐2920, MD05‐2930 and MD90‐0961 have been stacked and averaged. Variations of the authigenic 10Be/9Be ratio are analyzed and compared with the geomagnetic dipole low series reported from global RPI stacks. The largest 10Be overproduction episodes are related to dipole field collapses (below a threshold of 2 × 1022 Am2) associated with the Brunhes/Matuyama reversal, the Laschamp (41 ka) excursion, and the Iceland Basin event (190 ka). Other significant 10Be production peaks are correlated to geomagnetic excursions reported in literature. The record was then calibrated by using absolute dipole moment values drawn from the Geomagia and Pint paleointensity value databases. The 10Be‐derived geomagnetic dipole moment record, independent from sedimentary paleomagnetic data, covers the Brunhes‐Matuyama transition and the whole Brunhes Chron. It provides new and complementary data on the amplitude and timing of millennial‐scale geomagnetic dipole moment variations and particularly on dipole moment collapses triggering polarity instabilities. PMID:28163989
Bierman, P.R.; Marsella, K.A.; Patterson, Chris; Davis, P.T.; Caffee, M.
1999-01-01
Paired 10Be and 26Al analyses (n = 14) indicate that pre-Wisconsinan, glaciated bedrock surfaces near the northern (Baffin Island) and southern (Minnesota) paleo-margins of the Laurentide Ice Sheet have long and complex histories of cosmic-ray exposure, including significant periods of partial or complete shielding from cosmic rays. Using the ratio, 26Al/10Be, we calculate that striated outcrops of Sioux Quartzite in southwestern Minnesota (southern margin) were last overrun by ice at least 500,000 years ago. Weathered bedrock tors on the once-glaciated uplands of Baffin Island (northern margin) are eroding no faster than 1.1 m Myr-1, the equivalent of at least 450,000 years of surface and near-surface exposure. Our data demonstrate that exposure ages and erosion rates calculated from single nuclides can underestimate surface stability dramatically because any intermittent burial, and the resultant lowering of nuclide production rates and nuclide abundances, will remain undetected.
NASA Astrophysics Data System (ADS)
Lasche, George; Coldwell, Robert; Metzger, Robert
2017-09-01
A new application (known as "VRF", or "Visual RobFit") for analysis of high-resolution gamma-ray spectra has been developed using non-linear fitting techniques to fit full-spectrum nuclide shapes. In contrast to conventional methods based on the results of an initial peak-search, the VRF analysis method forms, at each of many automated iterations, a spectrum-wide shape for each nuclide and, also at each iteration, it adjusts the activities of each nuclide, as well as user-enabled parameters of energy calibration, attenuation by up to three intervening or self-absorbing materials, peak width as a function of energy, full-energy peak efficiency, and coincidence summing until no better fit to the data can be obtained. This approach, which employs a new and significantly advanced underlying fitting engine especially adapted to nuclear spectra, allows identification of minor peaks that are masked by larger, overlapping peaks that would not otherwise be possible. The application and method are briefly described and two examples are presented.
Radulescu, Georgeta; Gauld, Ian C.; Ilas, Germina; ...
2014-11-01
This paper describes a depletion code validation approach for criticality safety analysis using burnup credit for actinide and fission product nuclides in spent nuclear fuel (SNF) compositions. The technical basis for determining the uncertainties in the calculated nuclide concentrations is comparison of calculations to available measurements obtained from destructive radiochemical assay of SNF samples. Probability distributions developed for the uncertainties in the calculated nuclide concentrations were applied to the SNF compositions of a criticality safety analysis model by the use of a Monte Carlo uncertainty sampling method to determine bias and bias uncertainty in effective neutron multiplication factor. Application ofmore » the Monte Carlo uncertainty sampling approach is demonstrated for representative criticality safety analysis models of pressurized water reactor spent fuel pool storage racks and transportation packages using burnup-dependent nuclide concentrations calculated with SCALE 6.1 and the ENDF/B-VII nuclear data. Furthermore, the validation approach and results support a recent revision of the U.S. Nuclear Regulatory Commission Interim Staff Guidance 8.« less
Imaging multiple sclerosis and other neurodegenerative diseases
Inglese, Matilde; Petracca, Maria
2013-01-01
Although the prevalence of neurodegenerative diseases is increasing as a consequence of the growing aging population, the exact pathophysiological mechanisms leading to these diseases remains obscure. Multiple sclerosis (MS), an autoimmune disease of the central nervous system and the most frequent cause of disability among young people after traumatic brain injury, is characterized by inflammatory/demyelinating and neurodegenerative processes that occurr earlier in life. The ability to make an early diagnosis of MS with the support of conventional MRI techniques, provides the opportunity to study neurodegeneration and the underlying pathophysiological processes in earlier stages than in classical neurodegenerative diseases. This review summarizes mechanisms of neurodegeneration common to MS and to Alzheimer disease, Parkinson disease, and amiotrophic lateral sclerosis, and provides a brief overview of the neuroimaging studies employing MRI and PET techniques to investigate and monitor neurodegeneration in both MS and classical neurodegenerative diseases. PMID:23117868
NASA Technical Reports Server (NTRS)
Dragovitsch, P.; Englert, P.
1985-01-01
Through the interaction of galactic cosmic particle radiation (GCR) a wide variety of cosmogenic nuclides is produced in meteorites. They provide historical information about the cosmic radiation and the bombarded meteorites. An important way to understand the production mechanisms of cosmogenic nuclides in meteorites is to gather information about the depth and size dependence of the build-up of Galactic Rays Cosmic-secondary particles within meteorites of different sizes and chemical compositions. Simulation experiments with meteorite models offer an alternative to direct observation providing a data basis to describe the development and action of the secondary cascade induced by the GCR in meteorites.
Status of the PHOENIX electron cyclotron resonance charge breeder at ISOLDE, CERN.
Barton, Charles; Cederkall, Joakim; Delahaye, Pierre; Kester, Oliver; Lamy, Thierry; Marie-Jeanne, Mélanie
2008-02-01
We report here on the last progresses made with the PHOENIX electron cyclotron resonance charge breeder test bench at ISOLDE. Recently, an experiment was performed to test the trapping of (61)Fe daughter nuclides from the decay of (61)Mn nuclides. Preliminary results are given.
Potential clinical impact of radionuclide imaging technologies: highlights of the ITBS 2003 meeting
NASA Astrophysics Data System (ADS)
Itti, Roland
2004-07-01
Radiopharmaceuticals are major determinants of progress in Nuclear Medicine. Besides 18FDG, the most common PET tracer, several other molecules are under evaluation, such as 18F-fluoride for bone studies, numerous ligands for neurotransmission, 18F-DOPA for neuro-endocrine tumors or generator produced 68Ga-peptides for various cancers. Nuclear medicine gradually changes for "molecular imaging" and medical imaging, which was at the beginning mainly anatomic, has progressed in the direction of functional and metabolic imaging. The present challenge is to achieve some degree of "in vivo" biochemistry or even histology or genetics. The importance of anatomic/functional image fusion justifies the development of combined PET-CT instrumentation, whose objectives have to be discussed in terms of anatomical landmarks and/or additional clinical information. The question of "hard" or "soft" image co-registration remains open, involving not only CT, but also SPECT or MRI. Development of dedicated imaging devices, whether single photon or positron, is of major interest for breast imaging, allowing optimal imaging conditions, with results definitely superior to classical gamma-cameras or PET. The patient population concerned with scintimammography is still controversial, as well as the imaging modalities: FDG or sestaMIBI, planar or tomographic, scintillators or semi-conductors, and the research field remains open. This is also valid for external or per-operative probe systems for tumor or lymph nodes localization.
Nuclear cartography: patterns in binding energies and subatomic structure
NASA Astrophysics Data System (ADS)
Simpson, E. C.; Shelley, M.
2017-11-01
Nuclear masses and binding energies are some of the first nuclear properties met in high school physics, and can be used to introduce radioactive decays, fusion, and fission. With relatively little extension, they can also illustrate fundamental concepts in nuclear physics, such as shell structure and pairing, and to discuss how the elements around us were formed in stars. One way of visualising these nuclear properties is through the nuclide chart, which maps all nuclides as a function of their proton and neutron numbers. Here we use the nuclide chart to illustrate various aspects of nuclear physics, and present 3D visualisations of it produced as part of the binding blocks project.
The behavior of U- and Th-series nuclides in the estuarine environment
Swarzenski, P.W.; Porcelli, D.; Andersson, P.S.; Smoak, J.M.
2003-01-01
Rivers carry the products of continental weathering, and continuously supply the oceans with a broad range of chemical constituents. This erosional signature is, however, uniquely moderated by biogeochemical processing within estuaries. Estuaries are commonly described as complex filters at land-sea margins, where significant transformations can occur due to strong physico-chemical gradients. These changes differ for different classes of elements, and can vary widely depending on the geographic location. U- and Th-series nuclides include a range of elements with vastly different characteristics and behaviors within such environments, and the isotopic systematics provide methods for investigating the transport of these nuclides and other analog species across estuaries and into the coastal ocean.
Extraterrestrial Studies Using Nuclear Interactions
NASA Technical Reports Server (NTRS)
Reedy, Robert C.
2003-01-01
Cosmogenic nuclides were used to study the recent histories of the aubrite Norton County and the pallasite Brenham using calculated production rates. Calculations were done of the rates for making cosmogenic noble-gas isotopes in the Jovian satellite Europa by the interactions of galactic cosmic rays and especially trapped Jovian protons. Cross sections for the production of cosmogenic nuclides were reported and plans made to measure additional cross sections. A new code, MCNPX, was used to numerically simulate the interactions of cosmic rays with matter and the subsequent production of cosmogenic nuclides. A review was written about studies of extraterrestrial matter using cosmogenic radionuclides. Several other projects were done. Results are reviewed here with references to my recent publications for details.
Reactor-released radionuclides in Susquehanna River sediments
Olsen, C.R.; Larsen, I.L.; Cutshall, N.H.; Donoghue, J.F.; Bricker, O.P.; Simpson, H.J.
1981-01-01
Three Mile Island (TMI) and Peach Bottom (PB) reactors have introduced 137Cs, 134Cs, 60Co, 58Co and several other anthropogenic radionuclides into the lower Susquehanna River. Here we present the release history for these nuclides (Table 1) and radionuclide concentration data (Table 2) for sediment samples collected in the river and upper portions of the Chesapeake Bay (Fig. 1) within a few months after the 28 March 1979 loss-of-coolant-water problem at TMI. Although we found no evidence for nuclides characteristic of a ruptured fuel element, we did find nuclides characteristic of routine operations. Despite the TMI incident, more than 95% of the total 134Cs input to the Susquehanna has been a result of controlled low-level releases from the PB site. 134Cs activity released into the river is effectively trapped by sediments with the major zones of reactor-nuclide accumulation behind Conowingo Dam and in the upper portions of Chesapeake Bay. The reported distributions document the fate of reactor-released radionuclides and their extent of environmental contamination in the Susquehanna-Upper Chesapeake Bay System. ?? 1981 Nature Publishing Group.
Cosmic-ray Exposure Ages of Meteorites
NASA Astrophysics Data System (ADS)
Herzog, G. F.
2003-12-01
The classic idea of a cosmic-ray exposure (CRE) age for a meteorite is based on a simple but useful picture of meteorite evolution, the one-stage irradiation model. The precursor rock starts out on a parent body, buried under a mantle of material many meters thick that screens out cosmic rays. At a time ti, a collision excavates a precursor rock - a "meteoroid." The newly liberated meteoroid, now fully exposed to cosmic rays, orbits the Sun until a time tf, when it strikes the Earth, where the overlying blanket of air (and possibly of water or ice) again shuts out almost all cosmic rays (cf. Masarik and Reedy, 1995). The quantity tf-ti is called the CRE age, t. To obtain the CRE age of a meteorite, we measure the concentrations in it of one or more cosmogenic nuclides (Table 1), which are nuclides that cosmic rays produce by inducing nuclear reactions. Many shorter-lived radionuclides excluded from Table 1 such as 22Na (t1/2=2.6 yr) and 60Co (t1/2=5.27 yr) can also furnish valuable information, but can be measured only in meteorites that fell within the last few half-lives of those nuclides (see, e.g., Leya et al. (2001) and references therein). Table 1. Cosmogenic nuclides used for calculating exposure ages NuclideHalf-lifea (Myr) Radionuclides 14C0.005730 59Ni0.076 41Ca0.1034 81Kr0.229 36Cl0.301 26Al0.717 10Be1.51 53Mn3.74 129I15.7 Stable nuclides 3He 21Ne 38Ar 83Kr 126Xe a http://www2.bnl.gov/ton. CRE ages have implications for several interrelated questions. From how many different parent bodies do meteorites come? How well do meteorites represent the population of the asteroid belt? How many distinct collisions on each parent body have created the known meteorites of each type? How often do asteroids collide? How big and how energetic were the collisions that produced meteoroids? What factors control the CRE age of a meteorite and how do meteoroid orbits evolve through time? We will touch on these questions below as we examine the data.By 1975, the CRE ages of hundreds of meteorites had been estimated from noble gas measurements. Histograms of the CRE age distributions pointed to several important observations.(i) The CRE ages of meteorites increase in the order stones
NASA Astrophysics Data System (ADS)
Norton, K. P.; Wang, N.; Van Dissen, R. J.; Little, T.
2017-12-01
Fluvial sediments are archives of the erosional, transport, and depositional processes occurring in the catchment. Terraces become robust markers for geomorphic analysis if their time of abandonment can be determined. Methods such as OSL can determine burial ages for fine grained sediments within the terrace fill but may not be directly related to the terrace abandonment age. Cosmogenic nuclides can be used to determine exposure ages for geologically young terraces but the surface being dated may have been subsequently eroded and the material itself may have been deposited with an inherited nuclide concentration. To deal with this problem, many researchers collect multiple samples with depth to model the depth-dependent nuclide concentration to help constrain inheritance and post-depositional erosion. It is often, however, assumed that the entire sediment pile accumulated instantaneously. In this submission, we present the results of a depth profile model that incorporates sediment accumulation rate to improve terrace age estimates. We test this model on fault-offset river terraces near Kaikoura, New Zealand. We measured depth profiles of OSL ages and cosmogenic nuclide concentrations of two late Quaternary terraces that are offset by up to 800 m across the Kekerengu Fault. OSL ages and dated tephras in the overlying loess provide minimum age constraints for both terraces while OSL ages of fine-grained sediments within the fill provide depositional ages. The predicted sedimentation rates for the terraces are as high as 0.5m/yr, consistent with geologically instantaneous deposition. Modelled abandonment ages from cosmogenic nuclides for the terraces are consistent with OSL and tephra constraints at 9.7 +/- 3.8 ka and 30.4 +/- 2.1 ka, respectively. These terrace abandonment ages yield dextral slip rates of 18.5-20.5 mm/yr and 25-28 mm/yr, respectively, consistent with the rapid slip rate on the adjacent Hope Fault.
Nuclear Data Sheets for A = 84
NASA Astrophysics Data System (ADS)
Abriola, Daniel; Bostan, Melih; Erturk, Sefa; Fadil, Manssour; Galan, Monica; Juutinen, Sakari; Kibédi, Tibor; Kondev, Filip; Luca, Aurelian; Negret, Alexandru; Nica, Ninel; Pfeiffer, Bernd; Singh, Balraj; Sonzogni, Alejandro; Timar, Janos; Tuli, Jagdish; Venkova, Tsanka; Zuber, Kazimierz
2009-11-01
The evaluated spectroscopic data are presented for 12 known nuclides of mass 84 (Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo). Except for the stable nuclides 84Sr and 84Kr, extensive new data are available for all the other nuclides since the 1997 evaluation by J.K. Tuli (1997Tu02) of A = 84 nuclides. Many precise Penning-trap mass measurements since AME-2003 for A = 84 nuclides (2009Re03,2008Ha23,2008We10,2007Ke09,2006Ka48,2006De36,2006Ri15) have resulted in improved Q values and separation energies. However, many deficiencies still remain. Some examples are given below. Excited-state data for 84Ga and 84As are nonexistent, and those for 84Ge are scarce. The radioactive decay schemes of 84Ga, 84Ge, 84Se, 84Y (39.5 min), 84Y (4.6 s), 84Zr and 84Nb suffer from incompleteness and that for 84Mo decay is not known at all. The energy ordering of the two activities (39.5 min and and 4.6 s) of 84Y is not well established, although, high-spin with tentative spin-parity of (6+) is adopted here as the ground state of 84Y based on weak arguments. From a conference report published in 2000, it is clear that extensive experiments were done to investigate decays of 84Zr and 84Y, but details of these studies never appeared in literature and none were made available to the evaluators when requested from original authors. This evaluation was carried out as part of ENSDF workshop for Nuclear Structure and Decay Data Evaluators, organized and hosted by the "Horia Hulubei" National Institute for Physics and Nuclear Engineering, Bucharest, Romania during March 30, 2009 - April 3, 2009. Names of the evaluators principally responsible for evaluation of individual nuclides are given under the respective Adopted data sets.
Cosmogenic nuclide production within the atmosphere and long period comets
NASA Astrophysics Data System (ADS)
Overholt, Andrew C.
The Earth is constantly bombarded by cosmic rays. These high energy particles collide with target nuclei, producing a shower of secondary particles. These secondaries contribute significantly to the radiation background at sea level and in the atmosphere, as well as producing rare cosmogenic nuclides. This contribution is variable over long time scales as astrophysical events change the cosmic ray flux incident on the Earth. Our work re-examines a previously proposed climate effect of increased cosmic ray flux due to galactic location. Although our work does not support this effect, cosmic ray secondaries remain a threat to terrestrial biota. We calculate the cosmogenic neutron flux within the atmosphere as a function of primary spectrum. This work is pivotal in determining the radiation dose due to any arbitrary astrophysical event where the primary spectrum is known. Additionally, this work can be used to determine the cosmogenic nuclide production from such an event. These neutrons are the fundamental source of cosmogenic nuclides within our atmosphere and extraterrestrial matter. We explore the idea that excursions in 14C and 10Be abundances in the atmosphere may arise from direct deposition by long-period comet impacts, and those in 26Al from any bolide. We find that the amount of nuclide mass on large long-period comets entering the Earth's atmosphere may be sufficient for creating anomalies in the records of 14C and 10Be from past impacts. In particular, the estimated mass of the proposed Younger Dryas comet is consistent with its having deposited sufficient isotopes to account for recorded nuclide increases at that time. The 26Al/10Be ratio is much larger in extraterrestrial objects than in the atmosphere, and so, we note that measuring this ratio in ice cores is a suitable further test for the Younger Dryas impact hypothesis. This portion of our work may be used to find possible impact events in the geologic record as well as determination of a large bolide impact rate.
NASA Astrophysics Data System (ADS)
Spector, P. E.; Stone, J.; Hillebrand, T.; Gombiner, J. H.
2017-12-01
To investigate the response of the West Antarctic Ice Sheet (WAIS) to climatic conditions warmer than present, we are analyzing cosmogenic nuclides in a bedrock core from beneath 150 m of ice at a site near the Pirrit Hills. Our aim is to determine whether the WAIS has thinned in the past, exposing bedrock at this site, and if so, when. This will help to determine the vulnerability of the ice sheet to future warming, and identify climatic thresholds capable of inducing WAIS collapse. We selected a site where the ice-sheet surface lies at 1300 m, approximately halfway from the ice-sheet divide to the grounding line. We expect ice thickness at the site to reflect WAIS dynamics, rather than local meteorology or topography. Ice flow speeds are moderate and ice above the core site is thin enough to remain cold-based, limiting the possibility of subglacial erosion which would compromise the cosmogenic nuclide record. We targeted a subglacial ridge adjacent to an exposed granite nunatak. This lithology provides minerals suitable for analysis of multiple cosmogenic nuclides with different half-lives. Although we aimed to collect two cores from different depths to compare exposure histories, hydrofracture of the basal ice prevented us from reaching the bed at the first drill site. The second hole produced 5.5 m of discontinuous ice core above 8 m of bedrock core. Initial analyses of quartz from the bedrock show low levels of Be-10. Further analyses of Be-10, Al-26, Cl-36 and Ne-21 from the full length of the core will be required to determine whether this is because the surface has never been exposed, or because the cosmogenic nuclide profile has been truncated by glacial erosion. We will present comprehensive cosmogenic nuclide data, and discuss implications for WAIS deglaciation history, at the meeting. Supported by US National Science Foundation awards ANT-1142162 and PLR-1341728.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Balraj; Chen, Jun
2014-02-01
Evaluated experimental data are presented for 13 known nuclides of mass 85 (Zn, Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo). Since the previous 1990 evaluation of A=85, {sup 85}Zn, {sup 85}Ga, {sup 85}Ge and {sup 85}nuclides are newly added here. Excited state data for {sup 85}Se, {sup 85}Zr have become available from radioactive decay and in–beam γ–ray studies. New and improved high–spin data are available for {sup 85}Br, {sup 85}Kr, {sup 85}Rb, {sup 85}Y, {sup 85}Nb and {sup 85}Mo. New direct and precise measurement of atomic masses of {sup 85}Ge, {sup 85}As, {sup 85}Se, {supmore » 85}Br, {sup 85}Rb, {sup 85}Zr, {sup 85}Nb and {sup 85}Mo have greatly improved the landscape of β decay–Q values and separation energies in this mass region. In spite of extensive experimental work on the isobaric nuclei of this mass chain several deficiencies remain. No excited states are known in {sup 85}Zn, {sup 85}Ga, {sup 85}As. Only a few excited state are assigned in {sup 85}Ge from {sup 85}Ga β– decay. From radioactivity studies, the decay schemes of {sup 85}Zn and {sup 85}Mo are not known, and those for {sup 85}Ga, {sup 85}Ge, {sup 85}As and 10.9–s isomer of {sup 85}Zr are incomplete. Level lifetimes are not known for excited states in {sup 85}Se, {sup 85}Br, {sup 85}Nb and {sup 85}Mo. The {sup 85}Tc nuclide has not been detected in fragmentation experiments at GANIL, alluding to its unbound nature for proton emission. The {sup 85}Kr, {sup 85}Rb, {sup 85}Sr, and {sup 85}Y nuclides remain the most extensively studied from many different reactions and decays. The evaluation of A=85 nuclides has been done after a span of 23 years, thus includes an extensive amount of new data for almost each nuclide. This work supersedes the data for A=85 nuclides presented in earlier full NDS publication by J. Tepel in 1980Te04 and a later one published in an update mode by H. Sievers in 1991Si01.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makoto Kashiwagi; Garamszeghy, Mike; Lantes, Bertrand
Disposal of low-and intermediate-level activated waste generated at nuclear power plants is being planned or carried out in many countries. The radioactivity concentrations and/or total quantities of long-lived, difficult-to-measure nuclides (DTM nuclides), such as C-14, Ni-63, Nb-94, α emitting nuclides etc., are often restricted by the safety case for a final repository as determined by each country's safety regulations, and these concentrations or amounts are required to be known and declared. With respect to waste contaminated by contact with process water, the Scaling Factor method (SF method), which is empirically based on sampling and analysis data, has been applied asmore » an important method for determining concentrations of DTM nuclides. This method was standardized by the International Organization for Standardization (ISO) and published in 2007 as ISO21238 'Scaling factor method to determine the radioactivity of low and intermediate-level radioactive waste packages generated at nuclear power plants' [1]. However, for activated metal waste with comparatively high concentrations of radioactivity, such as may be found in reactor control rods and internal structures, direct sampling and radiochemical analysis methods to evaluate the DTM nuclides are limited by access to the material and potentially high personnel radiation exposure. In this case, theoretical calculation methods in combination with empirical methods based on remote radiation surveys need to be used to best advantage for determining the disposal inventory of DTM nuclides while minimizing exposure to radiation workers. Pursuant to this objective a standard for the theoretical evaluation of the radioactivity concentration of DTM nuclides in activated waste, is in process through ISO TC85/SC5 (ISO Technical Committee 85: Nuclear energy, nuclear technologies, and radiological protection; Subcommittee 5: Nuclear fuel cycle). The project team for this ISO standard was formed in 2011 and is composed of experts from 11 countries. The project team has been conducting technical discussions on theoretical methods for determining concentrations of radioactivity, and has developed the draft International Standard of ISO16966 'Theoretical activation calculation method to evaluate the radioactivity of activated waste generated at nuclear reactors' [2]. This paper describes the international standardization process developed by the ISO project team, and outlines the following two theoretical activity evaluation methods:? Point method? Range method. (authors)« less
Feasibility study of nuclear transmutation by negative muon capture reaction using the PHITS code
NASA Astrophysics Data System (ADS)
Abe, Shin-ichiro; Sato, Tatsuhiko
2016-06-01
Feasibility of nuclear transmutation of fission products in high-level radioactive waste by negative muon capture reaction is investigated using the Particle and Heave Ion Transport code System (PHITS). It is found that about 80 % of stopped negative muons contribute to transmute target nuclide into stable or short-lived nuclide in the case of 135Cs, which is one of the most important nuclide in the transmutation. The simulation result also indicates that the position of transmutation is controllable by changing the energy of incident negative muon. Based on our simulation, it takes approximately 8.5 × 108years to transmute 500 g of 135Cs by negative muon beam with the highest intensity currently available.
Virtanen, Kirsi A; Nuutila, Pirjo
2015-01-01
Adult humans have heat-producing and energy-consuming brown adipose tissue in the clavicular region of the neck. There are two types of brown adipose cells, the so-called classic and beige adipose cells. Brown adipose cells produce heat by means of uncoupler protein 1 (UCP1) from fatty acids and sugar. By applying positron emission tomography (PET) measuring the utilization of sugar, the metabolism of brown fat has been shown to multiply in the cold, presumably influencing energy consumption. Active brown fat is most likely present in young adults, persons of normal weight and women, least likely in obese persons.
PET monitoring of cancer therapy with 3He and 12C beams: a study with the GEANT4 toolkit.
Pshenichnov, Igor; Larionov, Alexei; Mishustin, Igor; Greiner, Walter
2007-12-21
We study the spatial distributions of beta(+)-activity produced by therapeutic beams of (3)He and (12)C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for heavy-ion therapy (MCHIT) based on the GEANT4 toolkit. The contributions from positron-emitting nuclei with T(1/2) > 10 s, namely (10,11)C, (13)N, (14,15)O, (17,18)F and (30)P, were calculated and compared with experimental data obtained during and after irradiation, where available. Positron-emitting nuclei are created by a (12)C beam in fragmentation reactions of projectile and target nuclei. This leads to a beta(+)-activity profile characterized by a noticeable peak located close to the Bragg peak in the corresponding depth-dose distribution. This can be used for dose monitoring in carbon-ion therapy of cancer. In contrast, as most of the positron-emitting nuclei are produced by a (3)He beam in target fragmentation reactions, the calculated total beta(+)-activity during or soon after the irradiation period is evenly distributed within the projectile range. However, we predict also the presence of (13)N, (14)O, (17,18)F created in charge-transfer reactions by low-energy (3)He ions close to the end of their range in several tissue-like media. The time evolution of beta(+)-activity profiles was investigated for both kinds of beams. We found that due to the production of (18)F nuclides the beta(+)-activity profile measured 2 or 3 h after irradiation with (3)He ions will have a distinct peak correlated with the maximum of depth-dose distribution. We also found certain advantages of low-energy (3)He beams over low-energy proton beams for reliable PET monitoring during particle therapy of shallow-located tumours. In this case the distal edge of beta(+)-activity distribution from (17)F nuclei clearly marks the range of (3)He in tissues.
Epidemiology of human toxocariasis in Poland - A review of cases 1978-2009.
Borecka, Anna; Kłapeć, Teresa
2015-01-01
Toxocariasis is a helminthozoonosis due to the infection of humans with larvae belonging to the Toxocara genus. Humans become infected as a result of accidental consumption of infected eggs containing third stage larvae (L3) nematodes from Toxocara canis or Toxocara cati species. Toxocariasis was recognized for the first time in the early 1950s, and the first cases of toxocariasis in Poland were described a few years later. Toxocariasis is clinically classified into several types: classic and incomplete visceral larva migrans (VLM) syndrome, ocular larva migrans (OLM) syndrome, neurological toxocariasis (NLM), covert toxocariasis and asymptomatic toxocariasis. In 1994-2005, 18,367 sera of people suspected of being infected with Toxocara were analysed, 1.8-76% had anti- Toxocara antibodies. In the period 1978-2009, 1,022 clinical cases of toxocariasis were recognized in Poland. In the opinion of the authors, in order to reduce the frequency of toxocariasis in human populations, some prophylaxis should undertaken, e.g. public education of zoonotic diseases, systematic control of animal, deworming of pets, cleaning pets' faeces by the owners.
Krammer, Julia; Dutschke, Anja; Kaiser, Clemens G; Schnitzer, Andreas; Gerhardt, Axel; Radosa, Julia C; Brade, Joachim; Schoenberg, Stefan O; Wasser, Klaus
2016-01-01
To evaluate whether tumor localization and method of preoperative biopsy affect sentinel lymph node (SLN) detection after periareolar nuclide injection in breast cancer patients. 767 breast cancer patients were retrospectively included. For lymphscintigraphy periareolar nuclide injection was performed and the SLN was located by gamma camera. Patient and tumor characteristics were correlated to the success rate of SLN mapping. SLN marking failed in 9/61 (14.7%) patients with prior vacuum-assisted biopsy and 80/706 (11.3%) patients with prior core needle biopsy. Individually evaluated, biopsy method (p = 0.4) and tumor localization (p = 0.9) did not significantly affect the SLN detection rate. Patients with a vacuum-assisted biopsy of a tumor in the upper outer quadrant had a higher odds ratio of failing in SLN mapping (OR 3.8, p = 0.09) compared to core needle biopsy in the same localization (OR 0.9, p = 0.5). Tumor localization and preoperative biopsy method do not significantly impact SLN mapping with periareolar nuclide injection. However, the failure risk tends to rise if vacuum-assisted biopsy of a tumor in the upper outer quadrant is performed.
Derivation of the Korean radwaste scaling factor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwang Yong Jee; Hong Joo Ahn; Se Chul Sohn
2007-07-01
The concentrations of several radionuclides in low and intermediate level radioactive waste (LILW) drums have to be determined before shipping to disposal facilities. A notice, by the Ministry of Science and Technology (MOST) of the Korean Government, related to the disposal of LILW drums came into effect at the beginning of 2005, with regards to a radionuclide regulation inside a waste drum. MOST allows for an indirect radionuclide assay using a scaling factor to measure the inventories due to the difficulty of nondestructively measuring the essential {alpha} and {beta}-emitting nuclides inside a drum. That is, a scaling factor calculated throughmore » a correlation of the {alpha} or {beta}-emitting nuclide (DTM, Difficult-To-Measure) with a {gamma}-emitting nuclide (ETM, Easy-To-Measure) which has systematically similar properties with DTM nuclides. In this study, radioactive wastes, such as spent resin and dry active waste which were generated at different sites of a PWR and a site of a PHWR type Korean NPP, were partially sampled and analyzed for regulated radionuclides by using radiochemical methods. According to a reactor type and a waste form, the analysis results of each radionuclide were classified. Korean radwaste scaling factor was derived from database of radionuclide concentrations. (authors)« less
Cosmogenic nuclides in the Martian surface: Constraints for sample recovery and transport
NASA Technical Reports Server (NTRS)
Englert, Peter A. J.
1988-01-01
Stable and radioactive cosmogenic nuclides and radiation damage effects such as cosmic ray tracks can provide information on the surface history of Mars. A recent overview on developments in cosmogenic nuclide research for historical studies of predominantly extraterrestrial materials was published previously. The information content of cosmogenic nuclides and radiation damage effects produced in the Martian surface is based on the different ways of interaction of the primary galactic and solar cosmic radiation (GCR, SCR) and the secondary particle cascade. Generally the kind and extent of interactions as seen in the products depend on the following factors: (1) composition, energy and intensity of the primary SCR and GCR; (2) composition, energy and intensity of the GCR-induced cascade of secondary particles; (3) the target geometry, i.e., the spatial parameters of Martian surface features with respect to the primary radiation source; (4) the target chemistry, i.e., the chemical composition of the Martian surface at the sampling location down to the minor element level or lower; and (5) duration of the exposure. These factors are not independent of each other and have a major influence on sample taking strategies and techniques.
Brusamolino, Ercole; Bacigalupo, Andrea; Barosi, Giovanni; Biti, Giampaolo; Gobbi, Paolo G; Levis, Alessandro; Marchetti, Monia; Santoro, Armando; Zinzani, Pier Luigi; Tura, Sante
2009-04-01
The Italian Society of Hematology (SIE), the Italian Society of Experimental Haematology (SIES) and the Italian Group for Bone Marrow Transplantation (GITMO) commissioned a project to develop practice guidelines for the initial work-up, therapy and follow-up of classical Hodgkin's lymphoma. Key questions to the clinical evaluation and treatment of this disease were formulated by an Advisory Committee, discussed and approved by an Expert Panel (EP) composed of senior hematologists and one radiotherapist. After a comprehensive and systematic literature review, the EP recommendations were graded according to their supporting evidence. An explicit approach to consensus methodologies was used for evidence interpretation and for producing recommendations in the absence of a strong evidence. The EP decided that the target domain of the guidelines should include only classical Hodgkin's lymphoma, as defined by the WHO classification, and exclude lymphocyte predominant histology. Distinct recommendations were produced for initial work-up, first-line therapy of early and advanced stage disease, monitoring procedures and salvage therapy, including hemopoietic stem cell transplant. Separate recommendations were formulated for elderly patients. Pre-treatment volumetric CT scan of the neck, thorax, abdomen, and pelvis is mandatory, while FDG-PET is recommended. As to the therapy of early stage disease, a combined modality approach is still recommended with ABVD followed by involved-field radiotherapy; the number of courses of ABVD will depend on the patient risk category (favorable or unfavorable). Full-term chemotherapy with ABVD is recommended in advanced stage disease; adjuvant radiotherapy in patients without initial bulk who achieved a complete remission is not recommended. In the elderly, chemotherapy regimens more intensive than ABVD are not recommended. Early evaluation of response with FDG-PET scan is suggested. Relapsed or refractory patients should receive high-dose chemotherapy and autologous hemopoietic stem cells transplant. Allogeneic transplant is recommended in patients relapsing after autologous transplant. All fertile patients should be informed of the possible effects of therapy on gonadal function and fertility preservation measures should be taken before the initiation of therapy.
18F-FLT PET/CT in the Evaluation of Pheochromocytomas and Paragangliomas: A Pilot Study.
Blanchet, Elise M; Taieb, David; Millo, Corina; Martucci, Victoria; Chen, Clara C; Merino, Maria; Herscovitch, Peter; Pacak, Karel
2015-12-01
(18)F-FDG PET/CT has been proven to be a highly sensitive method for pheochromocytomas/paragangliomas (PHEOs/PGLs) associated with succinate dehydrogenase (SDH) mutations. This finding has been attributed to altered tumor cell metabolism resulting from these mutations and does not provide additional prognostic information to genotype. Therefore, identification of new biomarkers for aggressiveness is needed. A high Ki-67 index was proposed to be an additional prognostic factor. This pilot study aimed to evaluate 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT) PET/CT, a PET proliferation tracer, as a potential imaging agent in a series of 12 PHEO/PGL patients with different genetic backgrounds, to compare (18)F-FLT uptake with (18)F-FDG PET/CT, and to evaluate classic factors of aggressiveness. Twelve patients (7 metastatic and 5 nonmetastatic) were prospectively evaluated with (18)F-FDG and (18)F-FLT and followed for at least 2 y after the initial imaging work-up. Uptake was assessed at a lesion level, visually and quantitatively by maximum standardized uptake values (SUVmax) for both tracers. (18)F-FLT uptake was compared with risk factors known to be linked with a poor prognosis in PGLs (SDHB-mutated status, lesion size, dopaminergic phenotype) and with (18)F-FDG uptake. In 12 patients, 77 lesions were assessed. All lesions had low (18)F-FLT uptake (median SUVmax, 2.25; range, 0.7-4.5). There was no apparent superiority of (18)F-FLT uptake in progressive lesions, and most of the lesions showed a mismatch, with high (18)F-FDG uptake (median SUVmax, 10.8; range, 1.1-79.0) contrasting with low (18)F-FLT uptake. This study suggests that PHEOs/PGLs-even those that progress-do not exhibit intense (18)F-FLT uptake. It provides the first in vivo demonstration that proliferation may not be a major determinant of (18)F-FDG uptake in these tumors. These findings provide new insight into the biologic behavior of PGL and suggest that antiproliferative agents may be suboptimal for treatment of these tumors. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
NASA Astrophysics Data System (ADS)
Lartizien, Carole; Tomei, Sandrine; Maxim, Voichita; Odet, Christophe
2007-03-01
This study evaluates new observer models for 3D whole-body Positron Emission Tomography (PET) imaging based on a wavelet sub-band decomposition and compares them with the classical constant-Q CHO model. Our final goal is to develop an original method that performs guided detection of abnormal activity foci in PET oncology imaging based on these new observer models. This computer-aided diagnostic method would highly benefit to clinicians for diagnostic purpose and to biologists for massive screening of rodents populations in molecular imaging. Method: We have previously shown good correlation of the channelized Hotelling observer (CHO) using a constant-Q model with human observer performance for 3D PET oncology imaging. We propose an alternate method based on combining a CHO observer with a wavelet sub-band decomposition of the image and we compare it to the standard CHO implementation. This method performs an undecimated transform using a biorthogonal B-spline 4/4 wavelet basis to extract the features set for input to the Hotelling observer. This work is based on simulated 3D PET images of an extended MCAT phantom with randomly located lesions. We compare three evaluation criteria: classification performance using the signal-to-noise ratio (SNR), computation efficiency and visual quality of the derived 3D maps of the decision variable λ. The SNR is estimated on a series of test images for a variable number of training images for both observers. Results: Results show that the maximum SNR is higher with the constant-Q CHO observer, especially for targets located in the liver, and that it is reached with a smaller number of training images. However, preliminary analysis indicates that the visual quality of the 3D maps of the decision variable λ is higher with the wavelet-based CHO and the computation time to derive a 3D λ-map is about 350 times shorter than for the standard CHO. This suggests that the wavelet-CHO observer is a good candidate for use in our guided detection method.
The exposure history of Jilin and production rates of cosmogenic nuclides
NASA Technical Reports Server (NTRS)
Heusser, G.
1986-01-01
Jilin, the largest known story meteorite, is a very suitable object for studying the systematics of cosmic ray produced nuclides in stony meteorites. Its well established two stage exposure history even permits to gain information about two different irradiation geometries (2pi and 4pi). All stable and long-lived cosmogenic nuclides measured in Jilin so far correlate well with each other. An example is shown where the Al-26 activities are plotted vs. the spallogenic Ne-21 concentration. These records of cosmic-ray interaction in Jilin can be used both to determine the history of the target and to study the nature of production rate profiles. This is unavoidably a bootstrap process, involving studying one with assumption about the other. Production rate equations are presented and discussed.
First chemical separation and identification of Seaborgium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tuerler, A.; Eichler, B.; Jost, D.T.
1997-12-31
The chemical properties of element 106 (Seaborgium, Sg) were successfully studied using the On-line Gas Chromatography Apparatus (OLGA III). After chemical separation of Sg in the form of volatile oxichlorides the nuclides {sup 265}Sg and {sup 266}Sg were unambiguously identified and their half-lives were determined for the first time. The Sg nuclides were produced from the {sup 248}Cm({sup 22}Ne, 4,5n){sup 266,265}Sg reaction at the GSI Darmstadt UNILAC accelerator. Simultaneously, short-lived W nuclides were produced from a small admixture of {sup 152}Gd to the Cm target material. As predicted by relativistic calculations and by extrapolations of chemical properties, it was demonstratedmore » that Sg oxichlorides are indeed less volatile than their lighter homologue W- and Mo-oxichlorides.« less
Chauhan, Kanchan; Tiwari, Anjani K; Chadha, Nidhi; Kaul, Ankur; Singh, Ajai Kumar; Datta, Anupama
2018-04-02
Homodimeric chalcone based 11 C-PET radiotracer, 11 C-(Chal) 2 DEA-Me, was synthesized, and binding affinity toward beta amyloid (Aβ) was evaluated. The computational studies revealed multiple binding of the tracer at the recognition sites of Aβ fibrils. The bivalent ligand 11 C-(Chal) 2 DEA-Me displayed higher binding affinity compared to the corresponding monomer, 11 C-Chal-Me, and classical Aβ agents. The radiolabeling yield with carbon-11 was 40-55% (decay corrected) with specific activity of 65-90 GBq/μmol. A significant ( p < 0.0001) improvement in the binding affinity of 11 C-(Chal) 2 DEA-Me with synthetic Aβ42 aggregates over the monomer, 11 C-Chal-Me, demonstrates the utility of the bivalent approach. The PET imaging and biodistribution data displayed suitable brain pharmacokinetics of both ligands with higher brain uptake in the case of the bivalent ligand. Metabolite analysis of healthy ddY mouse brain homogenates exhibited high stability of the radiotracers in the brain with >93% intact tracer at 30 min post injection. Both chalcone derivatives were fluorescent in nature and demonstrated significant changes in the emission properties after binding with Aβ42. The preliminary analysis indicates high potential of 11 C-(Chal) 2 DEA-Me as in vivo Aβ42 imaging tracer and highlights the significance of the bivalent approach to achieve a higher biological response for detection of early stages of amyloidosis.
NASA Astrophysics Data System (ADS)
Lifton, Nathaniel; Sato, Tatsuhiko; Dunai, Tibor J.
2014-01-01
Several models have been proposed for scaling in situ cosmogenic nuclide production rates from the relatively few sites where they have been measured to other sites of interest. Two main types of models are recognized: (1) those based on data from nuclear disintegrations in photographic emulsions combined with various neutron detectors, and (2) those based largely on neutron monitor data. However, stubborn discrepancies between these model types have led to frequent confusion when calculating surface exposure ages from production rates derived from the models. To help resolve these discrepancies and identify the sources of potential biases in each model, we have developed a new scaling model based on analytical approximations to modeled fluxes of the main atmospheric cosmic-ray particles responsible for in situ cosmogenic nuclide production. Both the analytical formulations and the Monte Carlo model fluxes on which they are based agree well with measured atmospheric fluxes of neutrons, protons, and muons, indicating they can serve as a robust estimate of the atmospheric cosmic-ray flux based on first principles. We are also using updated records for quantifying temporal and spatial variability in geomagnetic and solar modulation effects on the fluxes. A key advantage of this new model (herein termed LSD) over previous Monte Carlo models of cosmogenic nuclide production is that it allows for faster estimation of scaling factors based on time-varying geomagnetic and solar inputs. Comparing scaling predictions derived from the LSD model with those of previously published models suggest potential sources of bias in the latter can be largely attributed to two factors: different energy responses of the secondary neutron detectors used in developing the models, and different geomagnetic parameterizations. Given that the LSD model generates flux spectra for each cosmic-ray particle of interest, it is also relatively straightforward to generate nuclide-specific scaling factors based on recently updated neutron and proton excitation functions (probability of nuclide production in a given nuclear reaction as a function of energy) for commonly measured in situ cosmogenic nuclides. Such scaling factors reflect the influence of the energy distribution of the flux folded with the relevant excitation functions. Resulting scaling factors indicate 3He shows the strongest positive deviation from the flux-based scaling, while 14C exhibits a negative deviation. These results are consistent with a recent Monte Carlo-based study using a different cosmic-ray physics code package but the same excitation functions.
Conversion Factors Periodic Table of the Elements Chart of the Nuclides Map of the Nuclides Computer Index of (Atominstitut der Ãsterreichischen Universitäten) Neutron Activation Table of Elements Neutron Scattering at neutronsources.org. The information contained here in the Neutron Scattering Web has been
Johnson, T. D.; Singh, Balraj
2017-04-26
Evaluated experimental data are presented for 13 known mass 189 nuclides (Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po). Since the 2003Wu02 publication, structure and decay data from 25 new and primary publications have been incorporated in the current work, while adding a new 189Hf nuclide. New data have been added for all nuclides except 189Au and 189Hg. Moreover, several previous datasets were modified for β-decay Q values and conversion coefficients even when no new publications appeared since 2003Wu02. In spite of large amounts of data available for A=189 nuclides, several deficiencies remain, which aremore » pointed out below in the hope that further experimental work may improve our knowledge of structure of these nuclides. For 189Hf and 189Ta, ground-state half-lives, and their decay schemes are unknown. An isomer in 189Ta has recently been established but its decay characteristics are unknown, even though several gamma rays were connected with its decay. No excited states are known in 189W and only one in 189Po. The decay scheme of 189W is known poorly with most gamma rays left as unassigned. The decay schemes of 189Au and 189Pb g.s. suffer from incompleteness, while those for the g.s. and isomer of 189Tl are almost absent. The decay schemes of g.s. and isomer of 189Hg are very complex as apparent from the study by 1996Wo04. Evaluators feel that these two decay schemes could be improved with modern gamma-ray detector arrays. While several isomers are known in many of the A=189 nuclides, there is in general lack of information of level half-lives, thus limiting the knowledge of transition probabilities. High-spin structures, including SD bands in 189Hg and 189Tl, are known in 189Re, 189Ir, 189Pt, 189Au, 189Hg, 189Tl, 189Pb and 189Bi. Single-particle transfer data are available for 189Re, 189Os, and 189Pt; and two-neutron transfer data for 189Ir.« less
NASA Astrophysics Data System (ADS)
Johnson, T. D.; Singh, Balraj
2017-05-01
Evaluated experimental data are presented for 13 known mass 189 nuclides (Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po). Since the 2003Wu02 publication, structure and decay data from 25 new and primary publications have been incorporated in the current work, while adding a new 189Hf nuclide. New data have been added for all nuclides except 189Au and 189Hg. Moreover, several previous datasets were modified for β-decay Q values and conversion coefficients even when no new publications appeared since 2003Wu02. In spite of large amounts of data available for A=189 nuclides, several deficiencies remain, which are pointed out below in the hope that further experimental work may improve our knowledge of structure of these nuclides. For 189Hf and 189Ta, ground-state half-lives, and their decay schemes are unknown. An isomer in 189Ta has recently been established but its decay characteristics are unknown, even though several gamma rays were connected with its decay. No excited states are known in 189W and only one in 189Po. The decay scheme of 189W is known poorly with most gamma rays left as unassigned. The decay schemes of 189Au and 189Pb g.s. suffer from incompleteness, while those for the g.s. and isomer of 189Tl are almost absent. The decay schemes of g.s. and isomer of 189Hg are very complex as apparent from the study by 1996Wo04. Evaluators feel that these two decay schemes could be improved with modern gamma-ray detector arrays. While several isomers are known in many of the A=189 nuclides, there is in general lack of information of level half-lives, thus limiting the knowledge of transition probabilities. High-spin structures, including SD bands in 189Hg and 189Tl, are known in 189Re, 189Ir, 189Pt, 189Au, 189Hg, 189Tl, 189Pb and 189Bi. Single-particle transfer data are available for 189Re, 189Os, and 189Pt; and two-neutron transfer data for 189Ir.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, T. D.; Singh, Balraj
Evaluated experimental data are presented for 13 known mass 189 nuclides (Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po). Since the 2003Wu02 publication, structure and decay data from 25 new and primary publications have been incorporated in the current work, while adding a new 189Hf nuclide. New data have been added for all nuclides except 189Au and 189Hg. Moreover, several previous datasets were modified for β-decay Q values and conversion coefficients even when no new publications appeared since 2003Wu02. In spite of large amounts of data available for A=189 nuclides, several deficiencies remain, which aremore » pointed out below in the hope that further experimental work may improve our knowledge of structure of these nuclides. For 189Hf and 189Ta, ground-state half-lives, and their decay schemes are unknown. An isomer in 189Ta has recently been established but its decay characteristics are unknown, even though several gamma rays were connected with its decay. No excited states are known in 189W and only one in 189Po. The decay scheme of 189W is known poorly with most gamma rays left as unassigned. The decay schemes of 189Au and 189Pb g.s. suffer from incompleteness, while those for the g.s. and isomer of 189Tl are almost absent. The decay schemes of g.s. and isomer of 189Hg are very complex as apparent from the study by 1996Wo04. Evaluators feel that these two decay schemes could be improved with modern gamma-ray detector arrays. While several isomers are known in many of the A=189 nuclides, there is in general lack of information of level half-lives, thus limiting the knowledge of transition probabilities. High-spin structures, including SD bands in 189Hg and 189Tl, are known in 189Re, 189Ir, 189Pt, 189Au, 189Hg, 189Tl, 189Pb and 189Bi. Single-particle transfer data are available for 189Re, 189Os, and 189Pt; and two-neutron transfer data for 189Ir.« less
Nuclear Data Sheets for A = 84
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abriola, Daniel; Bostan, Melih; Erturk, Sefa
The evaluated spectroscopic data are presented for 12 known nuclides of mass 84 (Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo). Except for the stable nuclides {sup 84}Sr and {sup 84}Kr, extensive new data are available for all the other nuclides since the 1997 evaluation by J.K. Tuli (1997Tu02) of A = 84 nuclides. Many precise Penning-trap mass measurements since AME-2003 for A = 84 nuclides (2009Re03,2008Ha23,2008We10,2007Ke09,2006Ka48,2006De36,2006Ri15) have resulted in improved Q values and separation energies. However, many deficiencies still remain. Some examples are given below. Excited-state data for {sup 84}Ga and {sup 84}As are nonexistent,more » and those for {sup 84}Ge are scarce. The radioactive decay schemes of {sup 84}Ga, {sup 84}Ge, {sup 84}Se, {sup 84}Y (39.5 min), {sup 84}Y (4.6 s), {sup 84}Zr and {sup 84}Nb suffer from incompleteness and that for {sup 84}Mo decay is not known at all. The energy ordering of the two activities (39.5 min and and 4.6 s) of {sup 84}Y is not well established, although, high-spin with tentative spin-parity of (6+) is adopted here as the ground state of {sup 84}Y based on weak arguments. From a conference report published in 2000, it is clear that extensive experiments were done to investigate decays of {sup 84}Zr and {sup 84}Y, but details of these studies never appeared in literature and none were made available to the evaluators when requested from original authors. This evaluation was carried out as part of ENSDF workshop for Nuclear Structure and Decay Data Evaluators, organized and hosted by the 'Horia Hulubei' National Institute for Physics and Nuclear Engineering, Bucharest, Romania during March 30, 2009 - April 3, 2009. Names of the evaluators principally responsible for evaluation of individual nuclides are given under the respective Adopted data sets.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abriola, D.; Sonzogni, A.; Bostan,M. Erturk,S.
The evaluated spectroscopic data are presented for 12 known nuclides of mass 84 (Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo). Except for the stable nuclides {sup 84}Sr and {sup 84}Kr, extensive new data are available for all the other nuclides since the 1997 evaluation by J.K. Tuli (1997Tu02) of A = 84 nuclides. Many precise Penning-trap mass measurements since AME-2003 for A = 84 nuclides (2009Re03,2008Ha23,2008We10,2007Ke09,2006Ka48,2006De36,2006Ri15) have resulted in improved Q values and separation energies. However, many deficiencies still remain. Some examples are given below. Excited-state data for {sup 84}Ga and {sup 84}As are nonexistent,more » and those for {sup 84}Ge are scarce. The radioactive decay schemes of {sup 84}Ga, {sup 84}Ge, {sup 84}Se, {sup 84}Y (39.5 min), {sup 84}Y (4.6 s), {sup 84}Zr and {sup 84}Nb suffer from incompleteness and that for {sup 84}Mo decay is not known at all. The energy ordering of the two activities (39.5 min and and 4.6 s) of {sup 84}Y is not well established, although, high-spin with tentative spin-parity of (6+) is adopted here as the ground state of {sup 84}Y based on weak arguments. From a conference report published in 2000, it is clear that extensive experiments were done to investigate decays of {sup 84}Zr and {sup 84}Y, but details of these studies never appeared in literature and none were made available to the evaluators when requested from original authors. This evaluation was carried out as part of ENSDF workshop for Nuclear Structure and Decay Data Evaluators, organized and hosted by the 'Horia Hulubei' National Institute for Physics and Nuclear Engineering, Bucharest, Romania during March 30, 2009 - April 3, 2009. Names of the evaluators principally responsible for evaluation of individual nuclides are given under the respective Adopted data sets.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abriola, D.; Bostan, M.; Erturk, S.
The evaluated spectroscopic data are presented for 12 known nuclides of mass 84 (Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo). Except for the stable nuclides {sup 84}Sr and {sup 84}Kr, extensive new data are available for all the other nuclides since the 1997 evaluation by J.K. Tuli (1997Tu02) of A = 84 nuclides. Many precise Penning-trap mass measurements since AME-2003 for A = 84 nuclides (2009Re03,2008Ha23,2008We10,2007Ke09,2006Ka48,2006De36,2006Ri15) have resulted in improved Q values and separation energies. However, many deficiencies still remain. Some examples are given below. Excited-state data for {sup 84}Ga and {sup 84}As are nonexistent,more » and those for {sup 84}Ge are scarce. The radioactive decay schemes of {sup 84}Ga, {sup 84}Ge, {sup 84}Se, {sup 84}Y (39.5 min), {sup 84}Y (4.6 s), {sup 84}Zr and {sup 84}Nb suffer from incompleteness and that for {sup 84}Mo decay is not known at all. The energy ordering of the two activities (39.5 min and 4.6 s) of {sup 84}Y is not well established, although, high-spin with tentative spin-parity of (6+) is adopted here as the ground state of {sup 84}Y based on weak arguments. From a conference report published in 2000, it is clear that extensive experiments were done to investigate decays of {sup 84}Zr and {sup 84}Y, but details of these studies never appeared in literature and none were made available to the evaluators when requested from original authors. This evaluation was carried out as part of ENSDF workshop for Nuclear Structure and Decay Data Evaluators, organized and hosted by the 'Horia Hulubei' National Institute for Physics and Nuclear Engineering, Bucharest, Romania during March 30, 2009 - April 3, 2009. Names of the evaluators principally responsible for evaluation of individual nuclides are given under the respective Adopted data sets.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knogler, Thomas; El-Rabadi, Karem; Weber, Michael
2014-12-15
Purpose: To determine the diagnostic performance of three-dimensional (3D) texture analysis (TA) of contrast-enhanced computed tomography (CE-CT) images for treatment response assessment in patients with Hodgkin lymphoma (HL), compared with F-18-fludeoxyglucose (FDG) positron emission tomography/CT. Methods: 3D TA of 48 lymph nodes in 29 patients was performed on venous-phase CE-CT images before and after chemotherapy. All lymph nodes showed pathologically elevated FDG uptake at baseline. A stepwise logistic regression with forward selection was performed to identify classic CT parameters and texture features (TF) that enable the separation of complete response (CR) and persistent disease. Results: The TF fraction of imagemore » in runs, calculated for the 45° direction, was able to correctly identify CR with an accuracy of 75%, a sensitivity of 79.3%, and a specificity of 68.4%. Classical CT features achieved an accuracy of 75%, a sensitivity of 86.2%, and a specificity of 57.9%, whereas the combination of TF and CT imaging achieved an accuracy of 83.3%, a sensitivity of 86.2%, and a specificity of 78.9%. Conclusions: 3D TA of CE-CT images is potentially useful to identify nodal residual disease in HL, with a performance comparable to that of classical CT parameters. Best results are achieved when TA and classical CT features are combined.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hidy, Alan J.; Gosse, John C.; Sanborn, Paul
We report that Wounded Moose type paleosols developed on remnant deposits of Late Pliocene to Early Pleistocene [pre-Reid] Cordilleran Ice Sheet [CIS] glaciations in central Yukon, Canada. It is an important regional soil-geomorphic marker at the boundary between early CIS advances and the non-glaciated regions of Yukon and Alaska. Yet, at present, its age is poorly constrained between the Reid [0.2 Ma] and earliest [2.84 Ma] CIS advances. Here, we apply depth profiles of in situ-produced cosmogenic 26Al and 10Be to obtain both a minimum exposure age [1.12 +0.44/ -0.36 Ma, 2σ] and maximum erosion rate [1.1 +0.9/ -0.5 mmore » Myr -1] for the Wounded Moose paleosol. Here, our results show that this soil formed under exceptionally stable conditions [max erosion rate similar to polar bedrock erosion rates] and that it pre-dates the emergence of the 100 ka [eccentricity] climate cycle. Contrasting our results from single- and joint-nuclide depth profile models reveals a significant discrepancy between calculated and effective 10Be and 26Al production rates [40–65% of expected values]. We interpret this discrepancy as the result of intermittent loess cover—with a time-averaged depth between 60 and 110 cm—which significantly reduced apparent exposure ages obtained from the single–nuclide model. The observation of such a significant loess-cover effect on cosmogenic nuclide production has implications for exposure dating in glacial and periglacial environments; a multi-nuclide sampling strategy is required to quantify this effect.« less
Activity concentrations of radionuclides in energy production from peat, wood chips and straw
NASA Astrophysics Data System (ADS)
Hedvall, Robert Hans
1997-11-01
In this thesis quantitative analyses of radionuclide concentrations in bioenergy fuels such as peat, wood chips and straw are presented. For comparison a brief description is included of radionuclide concentrations and radiation doses from other sources of power and also from some industrial applications. Radiation is a natural phenomenon and radionuclides occur naturally. The first man-made spread of concentrated radioactivity occurred some 100,000 years ago when the first fireplace was lit, with fallout as a later consequence. Radioactive potassium is found in most materials and is the most easily detected nuclide in fuels. Its activity concentration in Bq kg-1 normally dominates over the concentration of other natural radionuclides. The radiation dose from potassium in the emission is nevertheless negligible. The most important radionuclides in the dose to humans are the U- and Th-isotopes and also 210Pb and 210Po. Of fission products in fallout from the atmospheric nuclear tests and after the Chernobyl accident, 137Cs was shown to be the most common nuclide. Compared to natural nuclides, the contribution from emission of 137Cs was shown to be the most common nuclide. Compared to natural nuclides, the contribution from emission of 137Cs is less than a few percent of the total dose to the population. A total dose of approximately a few μSv from inhalation only can be calculated from the emission of a district heating plant in Sweden. This dose can be compared with the annual dose limit to the public from nuclear industry, which is 0.1 mSv and the global collective effective dose of 5 person Sv a-1.
Hidy, Alan J.; Gosse, John C.; Sanborn, Paul; ...
2018-02-16
We report that Wounded Moose type paleosols developed on remnant deposits of Late Pliocene to Early Pleistocene [pre-Reid] Cordilleran Ice Sheet [CIS] glaciations in central Yukon, Canada. It is an important regional soil-geomorphic marker at the boundary between early CIS advances and the non-glaciated regions of Yukon and Alaska. Yet, at present, its age is poorly constrained between the Reid [0.2 Ma] and earliest [2.84 Ma] CIS advances. Here, we apply depth profiles of in situ-produced cosmogenic 26Al and 10Be to obtain both a minimum exposure age [1.12 +0.44/ -0.36 Ma, 2σ] and maximum erosion rate [1.1 +0.9/ -0.5 mmore » Myr -1] for the Wounded Moose paleosol. Here, our results show that this soil formed under exceptionally stable conditions [max erosion rate similar to polar bedrock erosion rates] and that it pre-dates the emergence of the 100 ka [eccentricity] climate cycle. Contrasting our results from single- and joint-nuclide depth profile models reveals a significant discrepancy between calculated and effective 10Be and 26Al production rates [40–65% of expected values]. We interpret this discrepancy as the result of intermittent loess cover—with a time-averaged depth between 60 and 110 cm—which significantly reduced apparent exposure ages obtained from the single–nuclide model. The observation of such a significant loess-cover effect on cosmogenic nuclide production has implications for exposure dating in glacial and periglacial environments; a multi-nuclide sampling strategy is required to quantify this effect.« less
Yamamoto, M; Sakaguchi, A; Ochiai, S; Takada, T; Hamataka, K; Murakami, T; Nagao, S
2014-06-01
Dust samples from the sides of roads (black substances) have been collected together with litter and soil samples at more than 100 sites contaminated heavily in the 20-km exclusion zones around Fukushima Dai-ichi Nuclear Power Plant (FDNPP) (Minamisoma City, and Namie, Futaba and Okuma Towns), in Iitate Village located from 25 to 45 km northwest of the plant and in southern areas from the plant. Isotopes of Pu, Am and Cm have been measured in the samples to evaluate their total releases into the environment from the FDNPP and to get the isotopic compositions among these nuclides. For black substances and litter samples, in addition to Pu isotopes, (241)Am, (242)Cm and (243,244)Cm were determined for most of samples examined, while for soil samples, only Pu isotopes were determined. The results provided a coherent data set on (239,240)Pu inventories and isotopic composition among these transuranic nuclides. When these activity ratios were compared with those for fuel core inventories in the FDNPP accident estimated by a group at JAEA, except (239,240)Pu/(137)Cs activity ratios, fairly good agreements were found, indicating that transuranic nuclides, probably in the forms of fine particles, were released into the environment without their large fractionations. The obtained data may lead to more accurate information about the on-site situation (e.g., burn-up, conditions of fuel during the release phase, etc.), which would be difficult to get otherwise, and more detailed information on the dispersion and deposition processes of transuranic nuclides and the behavior of these nuclides in the environment. Copyright © 2014 Elsevier Ltd. All rights reserved.
Nuclear Data Sheets for A = 222
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, S.; Tuli, J.; Jain,A.K.
The ENSDF evaluation for A=222 mass chain (1996El01) has been updated on the basis of the experimental results, since September 1995 (literature cutoff date in 1996El01), from various reaction and decay studies for all nuclides in A=222 mass chain (Z=84 to 92). A new nuclide ({sup 222}Po) has since been observed. In addition, new measurements have been reported in Rn, Th and Ra nuclides. The results obtained from various theoretical studies are given as comments. The updated level and decay schemes, and experimental decay and reaction data on which they are based, are summarized and presented for all the nuclidesmore » with mass number A=222. The adopted values of level energies, level spins and parities are given, and {gamma}-ray energies, intensities, as well as other nuclear properties are presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basu, S.K.; Sonzogni, A.A.
The experimental results from the various reaction and decay studies leading to nuclides in the A=150 mass chain have been reviewed. These data are summarized and presented, together with the adopted level schemes and properties, for the nuclides from Cs(Z=55) through Lu(Z=71). This evaluation replaces the previous evaluation by E. der Mateosian and J. K. Tuli (1995De28), which appeared in Nuclear Data Sheets 75, 827 (1995)
NASA Astrophysics Data System (ADS)
Basu, S. K.; Sonzogni, A. A.
2013-04-01
The experimental results from the various reaction and decay studies leading to nuclides in the A=150 mass chain have been reviewed. These data are summarized and presented, together with the adopted level schemes and properties, for the nuclides from Cs(Z=55) through Lu(Z=71). This evaluation replaces the previous evaluation by E. der Mateosian and J. K. Tuli (1995De28), which appeared in Nuclear Data Sheets 75, 827 (1995).
Rat Bite Fever and Streptobacillus moniliformis
Elliott, Sean P.
2007-01-01
Rat bite fever, caused by Streptobacillus moniliformis, is a systemic illness classically characterized by fever, rigors, and polyarthralgias. If left untreated, it carries a mortality rate of 10%. Unfortunately, its nonspecific initial presentation combined with difficulties in culturing its causative organism produces a significant risk of delay or failure in diagnosis. The increasing popularity of rats and other rodents as pets, together with the risk of invasive or fatal disease, demands increased attention to rat bite fever as a potential diagnosis. The clinical and biological features of rat bite fever and Streptobacillus moniliformis are reviewed, providing some distinguishing features to assist the clinician and microbiologist in diagnosis. PMID:17223620
Sensitivity Analysis of Nuclide Importance to One-Group Neutron Cross Sections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sekimoto, Hiroshi; Nemoto, Atsushi; Yoshimura, Yoshikane
The importance of nuclides is useful when investigating nuclide characteristics in a given neutron spectrum. However, it is derived using one-group microscopic cross sections, which may contain large errors or uncertainties. The sensitivity coefficient shows the effect of these errors or uncertainties on the importance.The equations for calculating sensitivity coefficients of importance to one-group nuclear constants are derived using the perturbation method. Numerical values are also evaluated for some important cases for fast and thermal reactor systems.Many characteristics of the sensitivity coefficients are derived from the derived equations and numerical results. The matrix of sensitivity coefficients seems diagonally dominant. However,more » it is not always satisfied in a detailed structure. The detailed structure of the matrix and the characteristics of coefficients are given.By using the obtained sensitivity coefficients, some demonstration calculations have been performed. The effects of error and uncertainty of nuclear data and of the change of one-group cross-section input caused by fuel design changes through the neutron spectrum are investigated. These calculations show that the sensitivity coefficient is useful when evaluating error or uncertainty of nuclide importance caused by the cross-section data error or uncertainty and when checking effectiveness of fuel cell or core design change for improving neutron economy.« less
Läppchen, Tilman; Kiefer, Yvonne; Holland, Jason P; Bartholomä, Mark D
2018-05-01
We recently developed a chelating platform based on the macrocycle 1,4,7-triazacyclononane with up to three five-membered azaheterocyclic arms for complexation of the PET nuclides gallium-68 and copper-64. The main objective of this study was to evaluate the stability and pharmacokinetics of 68 Ga- and 64 Cu-complexes of the bifunctional chelator NODIA-Me 1 covalently bound to a PSMA targeting vector in vivo. NODIA-Me 1 was conjugated to the PSMA targeting Glu-NH-CO-NH-Lys moiety to give the bioconjugate NODIA-Me-NaI-Ahx-PSMA 4. The stability of [ 68 Ga]4 and [ 64 Cu]4 was assessed in vitro by serum stability studies. The PSMA binding affinity was determined in competitive cell experiments in LNCaP cells using 68 Ga-PSMA-HBED-CC as radioligand. The stability and pharmacokinetics of [ 68 Ga]4 and [ 64 Cu]4 was evaluated by PET imaging and ex vivo biodistribution studies in mice bearing subcutaneous LNCaP tumors. In human serum, [ 68 Ga]4 and [ 64 Cu]4 remained intact to 85% (3 h) and 92% (24 h), respectively. Nature of the metal chelate influenced PSMA binding affinity with IC 50 of 233 ± 10 nM for uncomplexed 4, 681 ± 7 nM for Cu-4 and 176 ± 10 nM for Ga-4. In animal studies, [ 68 Ga]4 and [ 64 Cu]4 revealed low uptake (≤1% IA g -1 ) in the majority of organs. Kidney uptake at 1 h p.i. was 6.28 ± 0.92% IA g -1 and 4.96 ± 0.79% IA g -1 and specific tumor uptake was 1.33 ± 0.46% IA g -1 and 2.15 ± 0.38% IA g -1 for [ 68 Ga]4 and [ 64 Cu]4, respectively. The bifunctional chelator NODIA-Me 1 was successfully conjugated to a PSMA targeting moiety. In small-animal PET imaging and ex vivo biodistribution studies, 68 Ga- and 64 Cu-labelled conjugates specifically delineated PSMA-positive LNCaP tumors and exhibited rapid renal clearance from non-target tissues with no significant demetallation/transchelation in vivo. The results support further development of this novel chelating platform for production of 68 Ga- and 64 Cu-labelled radiopharmaceuticals. Copyright © 2017. Published by Elsevier Inc.
Surface Exposure Geochronology Using Cosmogenic Nuclides: Applications in Antarctic Glacial Geology
1994-02-01
Department of Marine Chemistry and Geochemistry Dist Special Dean of Graduate Studies I I I SURFACE EXPOSURE GEOCHRONOLOGY USING COSMOGENIC NUCLIDES... studies of Sirius Group tills. Comparison of measured 10Be concentrations in Sirius Group deposits with those predicted with a model of the effects of...that this deposit does not, 1 as previous studies suggested, represent a single ice advance in response to lowered sea level at the last glacial
Radio-nuclide mixture identification using medium energy resolution detectors
Nelson, Karl Einar
2013-09-17
According to one embodiment, a method for identifying radio-nuclides includes receiving spectral data, extracting a feature set from the spectral data comparable to a plurality of templates in a template library, and using a branch and bound method to determine a probable template match based on the feature set and templates in the template library. In another embodiment, a device for identifying unknown radio-nuclides includes a processor, a multi-channel analyzer, and a memory operatively coupled to the processor, the memory having computer readable code stored thereon. The computer readable code is configured, when executed by the processor, to receive spectral data, to extract a feature set from the spectral data comparable to a plurality of templates in a template library, and to use a branch and bound method to determine a probable template match based on the feature set and templates in the template library.
Multilayer Network Analysis of Nuclear Reactions
NASA Astrophysics Data System (ADS)
Zhu, Liang; Ma, Yu-Gang; Chen, Qu; Han, Ding-Ding
2016-08-01
The nuclear reaction network is usually studied via precise calculation of differential equation sets, and much research interest has been focused on the characteristics of nuclides, such as half-life and size limit. In this paper, however, we adopt the methods from both multilayer and reaction networks, and obtain a distinctive view by mapping all the nuclear reactions in JINA REACLIB database into a directed network with 4 layers: neutron, proton, 4He and the remainder. The layer names correspond to reaction types decided by the currency particles consumed. This combined approach reveals that, in the remainder layer, the β-stability has high correlation with node degree difference and overlapping coefficient. Moreover, when reaction rates are considered as node strength, we find that, at lower temperatures, nuclide half-life scales reciprocally with its out-strength. The connection between physical properties and topological characteristics may help to explore the boundary of the nuclide chart.
Lee, M H; Ahn, H J; Park, J H; Park, Y J; Song, K
2011-02-01
This paper presents a quantitative and rapid method of sequential separation of Pu, (90)Sr and (241)Am nuclides in environmental soil samples with an anion exchange resin and Sr Spec resin. After the sample solution was passed through an anion exchange column connected to a Sr Spec column, Pu isotopes were purified from the anion exchange column. Strontium-90 was separated from other interfering elements by the Sr Spec column. Americium-241 was purified from lanthanides by the anion exchange resin after oxalate co-precipitation. Measurement of Pu and Am isotopes was carried out using an α-spectrometer. Strontium-90 was measured by a low-level liquid scintillation counter. The radiochemical procedure of Pu, (90)Sr and (241)Am nuclides investigated in this study validated by application to IAEA reference materials and environmental soil samples. Copyright © 2010 Elsevier Ltd. All rights reserved.
Ellender, M; Harrison, J D; Pottinger, H; Thomas, J M
2001-01-01
To compare tumour induction in CBA/H mice, principally osteosarcoma and acute myeloid leukaemia, resulting from exposure to the alpha-emitting nuclides, uranium-233, plutonium-239 and americium-241, and to relate differences between the three nuclides to the pattern of dose delivery within tissues. Each nuclide was administered intraperitoneally in citrate solution to three groups of adult male CBA/H mice at levels of activity which gave estimated life-time average skeletal doses of about 0.25-0.3 Gy, 0.5-1 Gy and 1-2 Gy. Animals were carefully monitored and sacrificed as soon as they showed signs of ill health; tumours were identified by standard histopathological techniques. Statistical modelling by Cox regression showed that, considering all three nuclides together, there was a highly significant increase in risk of death from osteosarcoma or myeloid leukaemia with increasing dose rate. For osteosarcoma, the effect was significantly greater for 239Pu than 241Am, while separate analysis for 233U showed no significant increase with increasing dose rate. For example, the increase in relative risk of death from osteosarcoma for an increase in life-time average dose rate to bone of 1 mGyd(-1) was 4.2 (2.7-6.5) for 239Pu, 2.3 (1.4-3.4) for 241Am and 1.1 (0.4-3.1) for 233U. For myeloid leukaemia, there was no significant difference between 239Pu and 241Am in the effect of dose rate. The increase in relative risk from myeloid leukaemia for an increase in average dose rate of 1 mGyd(-1) was 1.8 (1.1-2.8) for 239Pu, 2.0 (1.4-2.9) for 241Am and 1.5 (0.8-2.7) for 233U. Significant increases in renal and hepatic carcinomas were also recorded in animals exposed to 233U and 241Am, respectively. Studies of the distribution of the nuclides within the skeleton, published separately, have shown differences in their retention in individual bones and within bone. The proportions of decays occurring near to endosteal bone surfaces and throughout bone marrow were in the order: 239Pu> 241Am>233U. For osteosarcoma, the relative effectiveness of the nuclides in terms of average bone dose, in the order 239Pu>241Am>233U, is consistent with the proportion of dose delivered near to endosteal surfaces. For myeloid leukaemia, the greater effectiveness of 239Pu and 241Am than 233U is consistent with their accumulation in marrow.
Factors influencing in situ gamma-ray measurements
NASA Astrophysics Data System (ADS)
Loonstra, E. H.; van Egmond, F. M.
2009-04-01
Introduction In situ passive gamma-ray sensors are very well suitable for mapping physical soil properties. In order to make a qualitative sound soil map, high quality input parameters for calibration are required. This paper will focus on the factors that affect the output of in situ passive gamma-ray sensors, the primary source, soil, not taken into account. Factors The gamma-ray spectrum contains information of naturally occurring nuclides 40K, 238U and 232Th and man-made nuclides like 137Cs, as well as the total count rate. Factors that influence the concentration of these nuclides and the count rate can be classified in 3 categories. These are sensor design, environmental conditions and operational circumstances. Sensor design The main elements of an in situ gamma-ray sensor that influence the outcome and quality of the output are the crystal and the spectrum analysis method. Material and size of the crystal determine the energy resolution. Though widely used, NaI crystals are not the most efficient capturer of gamma radiation. Alternatives are BGO and CsI. BGO has a low peak resolution, which prohibits use in cases where man-made nuclides are subject of interest. The material is expensive and prone to temperature instability. CsI is robust compared to NaI and BGO. The density of CsI is higher than NaI, yielding better efficiency, especially for smaller crystal sizes. More volume results in higher energy efficiency. The reduction of the measured spectral information into concentration of radionuclides is mostly done using the Windows analysis method. In Windows, the activities of the nuclides are found by summing the intensities of the spectrum found in a certain interval surrounding a peak. A major flaw of the Windows method is the limited amount of spectral information that is incorporated into the analysis. Another weakness is the inherent use of ‘stripping factors' to account for contributions of radiation from nuclide A into the peak of nuclide B. This can be overcome using Full Spectrum Analysis (FSA). This method incorporates virtually all data present in the measured gamma spectrum. In FSA, a Chi-squared algorithm is used to fit a set of "Standard Spectra" to the measured spectrum. The uncertainty in the FSA method is at least a factor 2 lower compared to the Windows method. Environmental conditions Environmental conditions can influence the signal output and therefore the quality. In general, the density of the medium through which gamma-radiation travels determines the interaction of the radiation with matter and thus affects the sensor readings. Excluding soil as being the source; water is the most important external factor in this respect. The amount of water in soil will affect the signal. In general, energy loss occurs as water content in soil increases. As a result, the nuclide concentrations will be lower. Monte Carlo simulations show a difference of 16% in nuclide concentration for completely dry and fully saturated sandy soils. Another water related issue is rainfall. With rain radon gas, a product of 238U, will precipitate. This causes spectral noise effects. Snow and fog have the same effect to a minor degree. Another aspect is the openness of soil. From experience we know that the concentration of 40K differs if soil is tilled. Finally, on earth there is always radioactive noise present from the galaxy. The "Standard Spectra" used in the FSA method can take noise and geometric effects into account. Operational circumstances During a survey an operator should be aware of the effects of driving speed and measurement height. In general, a larger crystal has better energy efficiency and is therefore more suitable for high speed. E.g. a 70 x 150 mm CsI crystal provides qualitative satisfactory output for soil mapping up to 10 km/hr. Sample locations, however, are best measured during a longer period (3 to 5 minutes). The measurement height affects the measurement resolution; the lower the sensor, the smaller the measured area. In addition, Monte Carlo simulations show that the mass of the survey vehicle has to be taken into account. A large tractor e.g. can lead to spectral shape disruptions of 5 to 10%. Conclusion Several factors can effect the measured concentrations of radioactive nuclides. Potential users should take mentioned factors into account in respect to their needs when building and applying gamma-ray sensors. For purposes of soil mapping the use of FSA method is preferred, as it incorporates several disturbing factors. This allows the user to create a consistent dataset which will lead to a better understanding of the relation between nuclide concentrations and physical soil properties.
NASA Astrophysics Data System (ADS)
Müller-Schauenburg, Wolfgang; Reimold, Matthias
Positron Emission Tomography is a well-established technique that allows imaging and quantification of tissue properties in-vivo. The goal of pharmacokinetic modelling is to estimate physiological parameters, e.g. perfusion or receptor density from the measured time course of a radiotracer. After a brief overview of clinical application of PET, we summarize the fundamentals of modelling: distribution volume, Fick's principle of local balancing, extraction and perfusion, and how to calculate equilibrium data from measurements after bolus injection. Three fundamental models are considered: (i) the 1-tissue compartment model, e.g. for regional cerebral blood flow (rCBF) with the short-lived tracer [15O]water, (ii) the 2-tissue compartment model accounting for trapping (one exponential + constant), e.g. for glucose metabolism with [18F]FDG, (iii) the reversible 2-tissue compartment model (two exponentials), e.g. for receptor binding. Arterial blood sampling is required for classical PET modelling, but can often be avoided by comparing regions with specific binding with so called reference regions with negligible specific uptake, e.g. in receptor imaging. To estimate the model parameters, non-linear least square fits are the standard. Various linearizations have been proposed for rapid parameter estimation, e.g. on a pixel-by-pixel basis, for the prize of a bias. Such linear approaches exist for all three models; e.g. the PATLAK-plot for trapping substances like FDG, and the LOGAN-plot to obtain distribution volumes for reversibly binding tracers. The description of receptor modelling is dedicated to the approaches of the subsequent lecture (chapter) of Millet, who works in the tradition of Delforge with multiple-injection investigations.
Investigating the Usefulness of Cosmogenic in situ 14C for the Dating of Alluvial Fan Surfaces
NASA Astrophysics Data System (ADS)
Goehring, B. M.; Blisniuk, K.; Moon, S.
2017-12-01
Accurate and unambiguous constraints on the age of alluvial fan surfaces remain one of the ultimate achievements for the application of cosmogenic nuclides exposure dating. Information on the age of a fan is not only useful for understanding the rate of sediment transfer from adjacent hillslopes, but also the displacement of an alluvial fan surface and their incised channels represent one of the clearest markers of long-term (102 - 104 years) slip along faults in many regions. Common nuclides such as 10Be, 26Al, and 36Cl, which are often applied to dating alluvial fans, are hampered by inheritance due to their long half-life as nuclides accumulate during exhumation and transport. Here, we present results from a systematic study investigating the usefulness of the cosmogenic nuclide carbon-14 (14C) from the Ash Wash Fan of the Anza Borrego Desert, California, which is well-dated with both 10Be of amalgamated boulder surfaces and U-series ages from pedogenic carbonates. We sampled individual boulders from multiple fan channel bars, rather than an amalgamation of many boulders from a single fan channel bar. Our new14C results yield a median ± half-interquartile age of 4.7 ± 0.8 ka (n = 4, 1 outlier removed). These results are in excellent agreement with the existing U-series and new p-IR-IRSL chronology (5.2 ± 0.3 ka and 5.5 ± 0.8 ka, respectively), but slightly younger than the previously published 10Be amalgamation date of 7.0 ± 1.0 ka. In contrast, 10Be exposure dates of the same boulder in our study yield a median ± half-interquartile age of 10.9 ± 2.6 ka, which we interpret to be the result of insufficient burial time during transport and/or erosion of the boulder to remove accumulated 10Be. Our results suggest that 14C may be a viable chronometer of alluvial fan surfaces less than ca. 25 ka. Finally, inspired by approaches in the burial dating community, we will also explore the possibility of a paired nuclide isochron approach. Measured 14C and 10Be concentrations display a strong correlation (r2 = 0.9), suggesting there may be gains to be made using a paired nuclide approach; we will explore this relationship further in the presentation.
Role of Core-collapse Supernovae in Explaining Solar System Abundances of p Nuclides
NASA Astrophysics Data System (ADS)
Travaglio, C.; Rauscher, T.; Heger, A.; Pignatari, M.; West, C.
2018-02-01
The production of the heavy stable proton-rich isotopes between 74Se and 196Hg—the p nuclides—is due to the contribution from different nucleosynthesis processes, activated in different types of stars. Whereas these processes have been subject to various studies, their relative contributions to Galactic chemical evolution (GCE) are still a matter of debate. Here we investigate for the first time the nucleosynthesis of p nuclides in GCE by including metallicity and progenitor mass-dependent yields of core-collapse supernovae (ccSNe) into a chemical evolution model. We used a grid of metallicities and progenitor masses from two different sets of stellar yields and followed the contribution of ccSNe to the Galactic abundances as a function of time. In combination with previous studies on p-nucleus production in thermonuclear supernovae (SNIa), and using the same GCE description, this allows us to compare the respective roles of SNeIa and ccSNe in the production of p-nuclei in the Galaxy. The γ process in ccSN is very efficient for a wide range of progenitor masses (13 M ⊙–25 M ⊙) at solar metallicity. Since it is a secondary process with its efficiency depending on the initial abundance of heavy elements, its contribution is strongly reduced below solar metallicity. This makes it challenging to explain the inventory of the p nuclides in the solar system by the contribution from ccSNe alone. In particular, we find that ccSNe contribute less than 10% of the solar p nuclide abundances, with only a few exceptions. Due to the uncertain contribution from other nucleosynthesis sites in ccSNe, such as neutrino winds or α-rich freeze out, we conclude that the light p-nuclides 74Se, 78Kr, 84Sr, and 92Mo may either still be completely or only partially produced in ccSNe. The γ-process accounts for up to twice the relative solar abundances for 74Se in one set of stellar models and 196Hg in the other set. The solar abundance of the heaviest p nucleus 196Hg is reproduced within uncertainties in one set of our models due to photodisintegration of the Pb isotopes 208,207,206Pb. For all other p nuclides, abundances as low as 2% of the solar level were obtained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, J.Y.; Lang, T.C.; Wei, H.J.
2007-07-01
The Fuel Cycle and Materials Administration (FCMA) in Taiwan announced a Supplementary Regulation for Classification of Low Radioactive Wastes, as well as the Regulation for Disposing of Low Radioactive Wastes and its Facility Safety Management in July 17, 1997, and September 10, 2003, respectively. The latter regulation states that in the future, before delivering low-level radioactive waste to a final land disposal site, each waste drum must specify the nuclide activity and be classified as class A, B, C or greater than C. The nuclide activity data for approximately 100,000 drums of low-level radwaste at the Lan-Yu temporary storage sitemore » accumulated in 1982-1995, therefore, must be established according to the above regulations. The original waste database at the Lan-Yu site indicates that the data were absent for about 9% and 72% of Co-60 and Cs-137 key nuclide activities, respectively. One of the principal tasks in this project was to perform whole drum gamma radioactivity analysis and contact dose rate counting to establish the relationship of dose-to-curie (D-to-C) of specific waste stream to derive gamma radioactivity of counting drums for 2 trenches repackaged at the Lan-Yu site. Utilizing regression function of Microsoft Excel and collected gamma data, a dose-to-curie relationship for the whole-drum radwaste is estimated in this study. Based on the relationship between radioactivity of various nuclides and the surface dose rate, an empirical function of the dose rate (Dose) associated with product of nuclide activity (Curie) and energy (Energy), CE is set up. Statistical data demonstrated that 838 whole drums were counted employing D-to-C approach to classify other 3,279 drums, and only the contact dose rate was detected for roughly 75% of the drums to estimate gamma radioactivity of whole drums, which can save considerable cost, time, and manpower. The 4,508 drums were classified as A and 7 drums as C after repackaging was complete. The estimation of D-to-C relationship was near 80% in those sorted drums. This methodology can provide a simple, easy and cost-effective way for inferring gamma nuclide activity. (authors)« less
Simulations of Terrestrial in-situ Cosmogenic-Nuclide Production
NASA Technical Reports Server (NTRS)
Reedy, R. C.; Nishiizumi, K.; Lal, D.; Arnold, J. R.; Englert, P. A. J.; Klein, J.; Middleton, R.; Jull, A. J. T.; Donahue, D. J.
1994-01-01
Targets of silicon and silicon dioxide were irradiated with spallation neutrons to simulate the production of long-lived radionuclides in the surface of the Earth. Gamma-ray spectroscopy was used to measure Be-7 and Na-22, and accelerator mass spectrometry was used to measure Be-10, C-14, and Al-26. The measured ratios of these nuclides are compared with calculated ratios and with ratios from other simulations and agree well with ratios inferred from terrestrial samples.
NASA Astrophysics Data System (ADS)
Huh, Chih-An; Hsu, Shih-Chieh; Lin, Chuan-Yao
2012-02-01
The 2011 Fukushima nuclear accident in Japan was the worst nuclear disaster following the 1986 Chernobyl accident. Fission products (nuclides) released from the Fukushima plant site since March 12, 2011 had been detected around the northern hemisphere in about two weeks and also in the southern hemisphere about one month later. We report here detailed time series of radioiodine and radiocesium isotopes monitored in a regional network around Taiwan, including one high-mountain and three ground-level sites. Our results show several pulses of emission from a sequence of accidents in the Fukushima facility, with the more volatile 131I released preferentially over 134Cs and 137Cs at the beginning. In the middle of the time series, there was a pronounced peak of radiocesium observed in northern Taiwan, with activity concentrations of 134Cs and 137Cs far exceeding that of 131I during that episode. From the first arrival time of these fission nuclides and their spatial and temporal variations at our sampling sites and elsewhere, we suggest that Fukushima-derived radioactive nuclides were transported to Taiwan and its vicinity via two pathways at different altitudes. One was transported in the free troposphere by the prevailing westerly winds around the globe; the other was transported in the planetary boundary layer by the northeast monsoon wind directly toward Taiwan.
The NUBASE2016 evaluation of nuclear properties
DOE Office of Scientific and Technical Information (OSTI.GOV)
Audi, G.; Kondev, F. G.; Wang, Meng
This paper presents the NUBASE2016 evaluation that contains the recommended values for nuclear and decay properties of 3437 nuclides in their ground and excited isomeric (T1/2≥100 ns) states. All nuclides for which any experimental information is known were considered. NUBASE2016 covers all data published by October 2016 in primary (journal articles) and secondary (mainly laboratory reports and conference proceedings) references, together with the corresponding bibliographical information. During the development of NUBASE2016, the data available in the “Evaluated Nuclear Structure Data File” (ENSDF) database were consulted and critically assessed for their validity and completeness. Furthermore, a large amount of new datamore » and some older experimental results that were missing from ENSDF were compiled, evaluated and included in NUBASE2016. The atomic mass values were taken from the “Atomic Mass Evaluation” (AME2016, second and third parts of the present issue). In cases where no experimental data were available for a particular nuclide, trends in the behavior of specific properties in neighboring nuclides (TNN) were examined. This approach allowed to estimate values for a range of properties that are labeled in NUBASE2016 as “non-experimental” (flagged “#”). Evaluation procedures and policies used during the development of this database are presented, together with a detailed table of recommended values and their uncertainties. AMDC: http://amdc.impcas.ac.cn/« less
Simulation of decay processes and radiation transport times in radioactivity measurements
NASA Astrophysics Data System (ADS)
García-Toraño, E.; Peyres, V.; Bé, M.-M.; Dulieu, C.; Lépy, M.-C.; Salvat, F.
2017-04-01
The Fortran subroutine package PENNUC, which simulates random decay pathways of radioactive nuclides, is described. The decay scheme of the active nuclide is obtained from the NUCLEIDE database, whose web application has been complemented with the option of exporting nuclear decay data (possible nuclear transitions, branching ratios, type and energy of emitted particles) in a format that is readable by the simulation subroutines. In the case of beta emitters, the initial energy of the electron or positron is sampled from the theoretical Fermi spectrum. De-excitation of the atomic electron cloud following electron capture and internal conversion is described using transition probabilities from the LLNL Evaluated Atomic Data Library and empirical or calculated energies of released X rays and Auger electrons. The time evolution of radiation showers is determined by considering the lifetimes of nuclear and atomic levels, as well as radiation propagation times. Although PENNUC is designed to operate independently, here it is used in conjunction with the electron-photon transport code PENELOPE, and both together allow the simulation of experiments with radioactive sources in complex material structures consisting of homogeneous bodies limited by quadric surfaces. The reliability of these simulation tools is demonstrated through comparisons of simulated and measured energy spectra from radionuclides with complex multi-gamma spectra, nuclides with metastable levels in their decay pathways, nuclides with two daughters, and beta plus emitters.
NASA Astrophysics Data System (ADS)
Qin, Zhenwei
1993-04-01
Although slow melting favors the generation of basaltic melt from a mantle matrix with large radioactive disequilibrium between two actinide nuclides ( MCKENZIE, 1985a), it results in long residence time in a magma chamber, during which the disequilibrium may be removed. An equilibrium melting model modified after MCKENZIE (1985a) is presented here which suggests that, for a given actinide parent-daughter pair, there exists a specific melting rate at which disequilibrium between these two nuclides reaches its maximum. This melting rate depends on the decay constant of the daughter nuclide concerned and the magma chamber volume scaled to that of its source. For a given scaled chamber size, large radioactive disequilibrium between two actinide nuclides in basalts will be observed if the melting rate is such that the residence time of the magma in the chamber is comparable to the mean life of the daughter nuclide. With a chamber size 1% in volume of the melting source, the melting rates at which maximum disequilibrium in basalts is obtained are 10 -7, 2 × 10 -7 and 3 × 10 -6y-1, respectively, for 238U- 230Th, 235U- 231Pa and 230Th- 226Ra. This implies that, while large disequilibrium between 238U- 230Th and between 235U- 231Pa may occur together, large 230Th- 226Ra disequilibrium will not coexist with large 238U- 230Th disequilibrium, consistent with some observations. The active mantle melting zone which supplies melt to a ridge axis is inferred to be only about 10 km thick and 50 km wide. The fraction of melt present in such a mantle source at any time is about 0.01 and 0.04, respectively, if melting rate is 10 -7 and 10 -6 y -1. The corresponding residence time of the residual melt in the matrix is 10 5 and 4 × 10 4y.
NASA Astrophysics Data System (ADS)
Riebe, C. S.; Arvin, L.; Ferrier, K.; Aciego, S.
2017-12-01
Cosmogenic nuclides have been widely used to quantify erosion in mountain ranges around the world, creating a global database of erosion rates from climatically and lithologically diverse sites, and providing vital clues about how mountain landscape evolution is coupled to Earth's carbon cycle and thus global climate change over geologic timescales. Despite this wealth of data, few studies have observed the widely expected strong control of erosion rates by climatic factors such as precipitation and temperature. Here we show that cosmogenic nuclide studies are prone to biases due to dust deposition and chemical erosion, which together can obscure strong relationships between climate and erosion rates. Erosion rates of sites exposed to intense chemical weathering can be underestimated by two-fold due to chemical enrichment of the cosmogenic target mineral quartz — a result of its high chemical erosion resistance, which increases its residence time and thus reduces its apparent erosion rate compared to other soil minerals. Meanwhile, erosion rates of sites with rapid dust deposition can be overestimated by more than ten-fold, due to dust's contributions to soil mass and target mineral abundance. Compilations of dust fluxes and cosmogenic nuclide data suggest that steep climatic trends in erosion rates, ranging from slow erosion rates in dry settings to twenty-fold faster erosion rates in wet settings, could be largely masked by the combined effects of dust deposition and chemical erosion. We argue that these effects need to be quantified in many cosmogenic nuclide studies of erosion rates. Doing so will require dust input rates; soil depth and density; quartz-enrichment ratios in both saprolite relative to bedrock and soil relative to saprolite; and quartz concentrations in deposited dust. Failure to quantify these crucial parameters can lead to misinterpretation of the strength — and even the sign — of feedbacks between climate and erosion rates in mountain landscapes.
NASA Astrophysics Data System (ADS)
Lowell, T. V.; Kelly, M. A.; Applegate, P. J.; Smith, C. A.; Phillips, F. M.; Hudson, A. M.
2010-12-01
We calibrate the production rate of the cosmogenic nuclide beryllium-10 (10Be) at a low-latitude, high-elevation site, using nuclide concentrations measured in moraine boulders and an independent chronology determined with bracketing radiocarbon dates. The measurement of terrestrial cosmogenic nuclide (TCN) concentrations in earth surface materials has been an important development for understanding a host of earth surface processes. Uncertainty in cosmogenic nuclide production rates has hampered application of this method. Here, we contribute to the estimation of 10Be production rates by reporting both preliminary 10Be concentrations and independent radiocarbon dates from a low latitude, high elevation site. Our study site in the southeastern Peruvian Andes (~13.9°S, 70.9°W, 4850 m asl) is centered on a moraine set, known as the Huancané II moraines, that represents a ~4 km expansion of Quelccaya Ice Cap during late glacial time. At this location, organic material situated both stratigraphically below and above moraines in two adjacent valleys provide material for radiocarbon dating. Based on geomorphic arguments, we correlate results from the two valleys. The timing of ice cap margin advance is bracketed by 13 radiocarbon ages on organic material within the outermost Huancané II moraines that range from 13.6 to 12.5 ka. Two stratigraphic sections upvalley from the moraines yield 6 radiocarbon ages from 11.3 to 12.4 ka, indicating the time of retreat . We computed the probability density function that lies between these two sets of dates, and assign an age of 12.4 ka (+/-???) for the formation of the Huancané II moraines. Calculating beryllium-10 exposure dates from the measured concentrations yield exposure dates that significantly underestimate the independently determined age of the moraine (~8-30%), if existing production rate estimates are used. We suggest that the radiocarbon age for the moraines can be used as a robust independent calibration for 10Be production rates at this site.
A Robust Deep Model for Improved Classification of AD/MCI Patients
Li, Feng; Tran, Loc; Thung, Kim-Han; Ji, Shuiwang; Shen, Dinggang; Li, Jiang
2015-01-01
Accurate classification of Alzheimer’s Disease (AD) and its prodromal stage, Mild Cognitive Impairment (MCI), plays a critical role in possibly preventing progression of memory impairment and improving quality of life for AD patients. Among many research tasks, it is of particular interest to identify noninvasive imaging biomarkers for AD diagnosis. In this paper, we present a robust deep learning system to identify different progression stages of AD patients based on MRI and PET scans. We utilized the dropout technique to improve classical deep learning by preventing its weight co-adaptation, which is a typical cause of over-fitting in deep learning. In addition, we incorporated stability selection, an adaptive learning factor, and a multi-task learning strategy into the deep learning framework. We applied the proposed method to the ADNI data set and conducted experiments for AD and MCI conversion diagnosis. Experimental results showed that the dropout technique is very effective in AD diagnosis, improving the classification accuracies by 5.9% on average as compared to the classical deep learning methods. PMID:25955998
ENDF/B-IV fission-product files: summary of major nuclide data
DOE Office of Scientific and Technical Information (OSTI.GOV)
England, T.R.; Schenter, R.E.
1975-09-01
The major fission-product parameters [sigma/sub th/, RI, tau/sub 1/2/, E- bar/sub $beta$/, E-bar/sub $gamma$/, E-bar/sub $alpha$/, decay and (n,$gamma$) branching, Q, and AWR] abstracted from ENDF/B-IV files for 824 nuclides are summarized. These data are most often requested by users concerned with reactor design, reactor safety, dose, and other sundry studies. The few known file errors are corrected to date. Tabular data are listed by increasing mass number. (auth)
Nuclear Data Sheets for A = 142
NASA Astrophysics Data System (ADS)
Johnson, T. D.; Symochko, D.; Fadil, M.; Tuli, J. K.
2011-08-01
The 2000 Nuclear Data Sheets for A=142 by J. K. Tuli, with literature cutoff date of February 4, 2000, has been revised. The evaluated experimental data are presented for 16 known nuclides of mass 142 (Ba, Ce, Cs, Dy, Eu, Gd, Ho, I, La, Nd, Pm, Pr, Sm, Tb, Te, Xe). Comparing to the previous evaluation (2000Tu01) significant changes were done to the level schemes of Gd, Cs, Ce and Nd. For all nuclides, the more recent Q values have been added.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, T.D.; Johnson,T.D.; Symochko,D.
The 2000 Nuclear Data Sheets for A = 142 by J. K. Tuli, with literature cutoff date of February 4, 2000, has been revised. The evaluated experimental data are presented for 16 known nuclides of mass 142 (Ba, Ce, Cs, Dy, Eu, Gd, Ho, I, La, Nd, Pm, Pr, Sm, Tb, Te, Xe). Comparing to the previous evaluation (2000Tu01) significant changes were done to the level schemes of Gd, Cs, Ce and Nd. For all nuclides, the more recent Q values have been added.
Background radiation and individual dosimetry in the costal area of Tamil Nadu, India.
Matsuda, Naoki; Brahmanandhan, G M; Yoshida, Masahiro; Takamura, Noboru; Suyama, Akihiko; Koguchi, Yasuhiro; Juto, Norimichi; Raj, Y Lenin; Winsley, Godwin; Selvasekarapandian, S
2011-07-01
South coast of India is known as the high-level background radiation area (HBRA) mainly due to beach sands that contain natural radionuclides as components of the mineral monazite. The rich deposit of monazite is unevenly distributed along the coastal belt of Tamil Nadu and Kerala. An HBRA site that laid in 2×7 m along the sea was found in the beach of Chinnavillai, Tamil Nadu, where the maximum ambient dose equivalent reached as high as 162.7 mSv y(-1). From the sands collected at the HBRA spot, the high-purity germanium semi-conductor detector identified six nuclides of thorium series, four nuclides of uranium series and two nuclides belonging to actinium series. The highest radioactivity observed was 43.7 Bq g(-1) of Th-228. The individual dose of five inhabitants in Chinnavillai, as measured by the radiophotoluminescence glass dosimetry system, demonstrated the average dose of 7.17 mSv y(-1) ranging from 2.79 to 14.17 mSv y(-1).
Miyatake, Hirokazu; Yoshizawa, Nobuaki; Suzuki, Gen
2018-05-11
The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident resulted in a release of radionuclides into the environment. Since the accident, measurements of radiation in the environment such as air dose rate and deposition density of radionuclides have been performed by various organizations and universities. In particular, Japan Atomic Energy Agency (JAEA) has been performing observations of air dose rate using a car-borne survey system continuously over widespread areas. Based on the data measured by JAEA, we estimated effective dose from external exposure in the prefectures surrounding Fukushima. Since car-borne survey started a few months after the accident, the main contribution to measured data comes from 137Cs and 134Cs whose half-lives are relatively long. Using air dose rate of 137Cs and 134Cs and the ratio of deposition density of short-lived nuclides to that of 137Cs and 134Cs, we also estimated contributions to the effective dose from other short-lived nuclides.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lumia, F.J.; Patil, A.; Germon, P.A.
In a retrospective study correlating the degree of tricuspid regurgitation seen on first-pass radionuclide angiography with that seen on contrast right ventriculography in 51 patients, ten had no tricuspid regurgitation by contrast ventriculography, whereas by radionuclide angiography nine had no regurgitation and one had minimal regurgitation. Of eight patients with minimal tricuspid regurgitation by contrast ventriculography, five had minimal regurgitation by nuclide angiography and three had no regurgitation. Of the 11 patients with mild to moderate tricuspid regurgitation by contrast studies, ten had mild to moderate regurgitation and one had severe regurgitation by nuclide angiography. Of 22 patients with moderatemore » to severe tricuspid regurgitation by contrast studies, 15 had moderate to severe regurgitation and seven had mild to moderate regurgitation by nuclear angiography. In this preliminary study comparing radionuclide angiography with contrast right ventriculography, there were three false-negative and one false-positive nuclide angiograms, giving a sensitivity of 93% and a specificity of 90%.« less
NASA Technical Reports Server (NTRS)
Sarafin, R.; Herpers, U.; Englert, P.; Wieler, R.; Signer, P.; Bonani, G.; Hofmann, H. J.; Morenzoni, E.; Nessi, M.; Suter, M.
1986-01-01
Measurements of stable and radioactive spallation products in meteorites allow to investigate their histories, especially with respect to the exposure to galactic cosmic ray particles and the pre-atmospheric size of the object. While the concentrations of spallation products lead to the determination of exposure and terrestrial ages, production rate ratios are characteristic for the location of the sample in the meteorite. So, one of the aims of this investigation on meteorites is to obtain depth indicators from suitable pairs of cosmogenic nuclides. Because of the different depth profiles for nuclide productions it is necessary to determine the concentrations of a larger number of spallation products in aliquots of a single small sample. Such same sample measurements of Be-10 and light noble gases were performed on 15 ordinary chondrites (7 H- and 8 L-chondrites. Be-10 was determined by accelerator mass spectrometry and the noble gases were measured by static mass spectrometry. The results are summarized and discussed.
Montenero, Michael P; Dilbone, Elizabeth K; Waples, James T
2017-10-01
In pelagic waters, the removal of particle-reactive radionuclides is controlled by nuclide sorption to particles and subsequent settling by gravity. However, in shallow nearshore waters, the dominant mechanism of nuclide scavenging is not so clear. Understanding how particle-reactive radionuclides are scavenged from the water column is critical if these tracers are to be used as proxies of particle flux in shallow aquatic systems. In this study, we present evidence that the removal of particle-reactive radionuclides in nearshore and turbulent waters is primarily controlled by bottom scavenging. Specifically, we measured both water column and bottom sediment activities of sewage-sourced iodine-131 ( 131 I, t ½ = 8.02 days) and atmospherically-sourced beryllium-7 ( 7 Be, t ½ = 53.3 days) in a semi-enclosed harbor. We show that the water column 7 Be/ 131 I flux ratio that is required to sustain observed harbor bottom inventories of both nuclides is incongruent with 7 Be/ 131 I activity ratios on water column particles, and (2) 131 I and 7 Be derived mass fluxes of particulate matter to the harbor bottom are in concordance with each other and independently made estimates of river sediment loading to the harbor only when bottom scavenging of both particle-bound and dissolved (<0.7 μm) nuclide fractions are considered. Copyright © 2017 Elsevier Ltd. All rights reserved.
The NUBASE2016 evaluation of nuclear properties
NASA Astrophysics Data System (ADS)
Audi, G.; Kondev, F. G.; Wang, Meng; Huang, W. J.; Naimi, S.
2017-03-01
This paper presents the NUBASE2016 evaluation that contains the recommended values for nuclear and decay properties of 3437 nuclides in their ground and excited isomeric (T1/2 >= 100 ns) states. All nuclides for which any experimental information is known were considered. NUBASE2016 covers all data published by October 2016 in primary (journal articles) and secondary (mainly laboratory reports and conference proceedings) references, together with the corresponding bibliographical information. During the development of NUBASE2016, the data available in the 'Evaluated Nuclear Structure Data File' (ENSDF) database were consulted and critically assessed for their validity and completeness. Furthermore, a large amount of new data and some older experimental results that were missing from ENSDF were compiled, evaluated and included in NUBASE2016. The atomic mass values were taken from the 'Atomic Mass Evaluation' (AME2016, second and third parts of the present issue). In cases where no experimental data were available for a particular nuclide, trends in the behavior of specific properties in neighboring nuclides (TNN) were examined. This approach allowed to estimate values for a range of properties that are labeled in NUBASE2016 as 'non-experimental' (flagged '#'). Evaluation procedures and policies used during the development of this database are presented, together with a detailed table of recommended values and their uncertainties. AMDC: http://amdc.impcas.ac.cn/ Contents The NUBASE2016 evaluation of nuclear propertiesAcrobat PDF (1.1 MB) Table I. The NUBASE2016 table of nuclear and decay propertiesAcrobat PDF (706 KB)
Kumar, Anita; Casulo, Carla; Yahalom, Joachim; Schöder, Heiko; Barr, Paul M; Caron, Philip; Chiu, April; Constine, Louis S; Drullinsky, Pamela; Friedberg, Jonathan W; Gerecitano, John F; Hamilton, Audrey; Hamlin, Paul A; Horwitz, Steven M; Jacob, Alexandra G; Matasar, Matthew J; McArthur, Gianna N; McCall, Susan J; Moskowitz, Alison J; Noy, Ariela; Palomba, Maria L; Portlock, Carol S; Straus, David J; VanderEls, Nicholas; Verwys, Stephanie L; Yang, Joanna; Younes, Anas; Zelenetz, Andrew D; Zhang, Zhigang; Moskowitz, Craig H
2016-09-15
This multicenter pilot study assessed the safety and efficacy of brentuximab vedotin (BV) and AVD (adriamycin, vinblastine, and dacarbazine) followed by 30 Gy involved site radiation therapy (ISRT). Patients with newly diagnosed, early stage classical Hodgkin lymphoma (HL) with unfavorable-risk features were treated with 4 cycles of BV and AVD. Patients who achieved a negative positron emission tomography (PET) scan (Deauville score of 1-3) received 30 Gy ISRT. Thirty patients received treatment and were assessable for toxicity. Twenty-nine patients completed 4 cycles of BV + AVD, and 25 patients BV + AVD + 30 Gy ISRT. No clinically significant noninfectious pneumonitis was observed. Serious adverse events (≥grade 3) were reported in 4 patients, including febrile neutropenia, peripheral neuropathy, and hypertension. After 2 and 4 cycles of BV + AVD, 90% (26 of 29) and 93% (27 or 29) of patients achieved a negative PET scan, respectively. Two patients with biopsy-proven primary refractory HL were treated off-study. All 25 patients who completed BV + AVD + ISRT achieved a complete response. With a median follow-up of 18.8 months, by intent to treat, the 1-year progression-free survival is 93.3% (95% confidence interval, 84-102). Overall, the treatment was well-tolerated with no evidence of significant pulmonary toxicity. The majority of patients (≥90%) achieved negative interim PET scans after 2 and 4 cycles of BV + AVD. Excluding the 2 primary refractory patients, all patients are disease free, suggesting that this is a highly active treatment program even in patients with substantial disease bulk. This trial was registered at www.clinicaltrials.gov as #NCT01868451. © 2016 by The American Society of Hematology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cameron J.; Nica N.; Cameron,J.
2012-02-01
Nuclear spectroscopic information for experimentally investigated nuclides of mass 37 (Na, Mg, Al, Si, P, S, Cl, Ar, K, Ca) has been evaluated. The principal sources of the 'adopted levels' presented for nuclides close to the stability line are Endt's evaluations (1990En08, 1978En02). The data sets for reactions and decays, including all available gamma-ray data, are based mostly on the original literature. There are no data available for the excited states in {sup 37}Na, {sup 37}Mg, {sup 37}Al; and for {sup 37}Si, only one excited state is known.
Cho, Herman
2016-02-28
Allowed transition energies and eigenstate expansions have been calculated and tabulated in numerical form as functions of the electric field gradient asymmetry parameter for the zero field Hamiltonian of quadrupolar nuclides with I = 3/2,5/2,7/2, and 9/2. These results are essential to interpret nuclear quadrupole resonance (NQR) spectra and extract accurate values of the electric field gradient tensors. Furthermore, applications of NQR methods to studies of electronic structure in heavy element systems are proposed.
Evaluated nuclear structure data file
NASA Astrophysics Data System (ADS)
Tuli, J. K.
1996-02-01
The Evaluated Nuclear Structure Data File (ENSDF) contains the evaluated nuclear properties of all known nuclides, as derived both from nuclear reaction and radioactive decay measurements. All experimental data are evaluated to create the adopted properties for each nuclide. ENSDF, together with other numeric and bibliographic files, can be accessed on-line through the INTERNET or modem, and some of the databases are also available on the World Wide Web. The structure and the scope of ENSDF are presented along with the on-line access system of the National Nuclear Data Center at Brookhaven National Laboratory.
Evaluated nuclear structure data file
NASA Astrophysics Data System (ADS)
Tuli, J. K.
The Evaluated Nuclear Structure Data File (ENSDF) contains the evaluated nuclear properties of all known nuclides. These properties are derived both from nuclear reaction and radioactive decay measurements. All experimental data are evaluated to create the adopted properties for each nuclide. ENSDF, together with other numeric and biographic files, can be accessed on-line through the INTERNET or modem. Some of the databases are also available on the World Wide Web. The structure and the scope of ENSDF are presented along with the on-line access system of the National Nuclear Data Center at Brookhaven National Laboratory.
NASA Astrophysics Data System (ADS)
Cosmic rays interact with the earth's atmosphere and surface to produce the “cosmogenic” nuclides. In many instances the radioactive ones are readily distinguished from the anthropogenic and meteoritic backgrounds. Measurements of these cosmogenic radionuclides (RCN) can contribute to the solution of a variety of geophysical problems [Lai and Peters, 1967]. Recent progress in this area was discussed at a symposium entitled Application of Cosmic-Ray-Produced Nuclides in Geophysics held May 30, 1983, at the AGU Spring Meeting in Baltimore (see Eos, May 3, 1983, pp. 282-284, for the abstracts). We summarize here the symposium presentations.
Chart of Nuclides Click on a nucleus for information Color code Half-life Decay Mode Qβ- QEC QÎ Radiation Help - Glossary This site is better seen using the latest version of internet browsers. Database ²+ Sn Sp Qα S2n S2p Q2β- Q2EC QECp Qβ-n BE/A (BE-LDM Fit)/A E1st ex. st. E2+ E3- E4+ E4+/E2+ β2 B(E2
Evaluation of Ruthenium Capture Methods for Tritium Pretreatment Off-Gas Streams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spencer, Barry B.; Jubin, Robert Thomas; Bruffey, Stephanie H.
2017-07-01
In the reprocessing of used nuclear fuel, radioactive elements are released into various plant off-gas streams. While much research and development has focused on the abatement of the volatile nuclides 3H, 14C, 85Kr, and 129I, the potential release of semivolatile isotopes that could also report to the off-gas streams in a reprocessing facility has been examined. Ruthenium (as 106Ru) has been identified as one of the semivolatile nuclides requiring the greatest degree of abatement prior to discharging the plant off-gas to the environment.
Steinnes, E.; Rowe, J.J.
1976-01-01
Instrumental neutron activation analysis is applied to the determination of about 25 elements in coals and fly ash by means of nuclides with half-lives of less than 48 h ; thermal and epithermal irradiations are used. The results indicate that epithermal activation is preferable for twelve of the elements (Ga, As, Br, Sr, In, Cs, Ba, La, Sm, Ho, W and U). Data for SRM 1632 (coal) and SRM 1633 (fly ash) compare favorably with the results obtained by other investigators. ?? 1976.
NASA Astrophysics Data System (ADS)
Pini, R.; Vandehey, N. T.; O'Neil, J.; Benson, S. M.
2015-12-01
We report results of an experimental investigation into the effects of small-scale (mm-cm) heterogeneities and hydrodynamic dispersion on miscible and immiscible displacements in a Berea Sandstone core. Pulse-radiotracer tests were carried out by measuring breakthrough curves at distinct flow rates and gas/water saturation ratios, while simultaneously imaging the internal displacement of the radioactive solution by [11C]PET. Dynamic multidimensional maps of the tracer concentration in the rock sample have been obtained with a spatial resolution of about 10 mm3 and provide evidence for significant macrodispersion effects caused by the presence of heterogeneities at the same scale. The numerical solution of the classic Advection-Dispersion Equation (ADE) applied in 1D form fails to describe the measured breakthrough curves and significantly overestimates longitudinal dispersivity. An excellent agreement with the experiments is attained by explicitly accounting for permeability heterogeneity, while reducing the contribution of "Fickian" dispersivity. Heterogeneity was introduced in the model by discretising the rock sample into independent parallel streamlines, which were generated based on a previously determined 3D permeability map, and by solving the 1D ADE for each of them. The use of streamlines is supported by direct quantitative observations from the PET scans; remarkably, this approach leads to an accurate representation of both the temporal behaviour and spatial distribution of the tracer concentration in the sample. It is shown that when the length-scale of permeability variations is similar in order as the size of the sample, the effect of the former can be as significant as hydrodynamic dispersion. The presence of a second immiscible fluid phase further complicates the flow field and, accordingly, the interpretation of the experiments. The ability to decouple these effects leads to the estimation of dispersion coefficients that aren't sample specific and are therefore better suited for up-scaling fluid mixing and dispersion in rocks. In this context, PET provides significant opportunities to advance our understanding of fluids displacements in rocks, thus including complex flows that involve additional phenomena, such as adsorption and chemical reactions.
Bouallègue, Fayçal Ben; Crouzet, Jean-François; Comtat, Claude; Fourcade, Marjolaine; Mohammadi, Bijan; Mariano-Goulart, Denis
2007-07-01
This paper presents an extended 3-D exact rebinning formula in the Fourier space that leads to an iterative reprojection algorithm (iterative FOREPROJ), which enables the estimation of unmeasured oblique projection data on the basis of the whole set of measured data. In first approximation, this analytical formula also leads to an extended Fourier rebinning equation that is the basis for an approximate reprojection algorithm (extended FORE). These algorithms were evaluated on numerically simulated 3-D positron emission tomography (PET) data for the solution of the truncation problem, i.e., the estimation of the missing portions in the oblique projection data, before the application of algorithms that require complete projection data such as some rebinning methods (FOREX) or 3-D reconstruction algorithms (3DRP or direct Fourier methods). By taking advantage of all the 3-D data statistics, the iterative FOREPROJ reprojection provides a reliable alternative to the classical FOREPROJ method, which only exploits the low-statistics nonoblique data. It significantly improves the quality of the external reconstructed slices without loss of spatial resolution. As for the approximate extended FORE algorithm, it clearly exhibits limitations due to axial interpolations, but will require clinical studies with more realistic measured data in order to decide on its pertinence.
Sobrio, Franck
2013-01-01
l-Glutamate is the major neurotransmitter in the central nervous system and activates both ionotropic and metabotropic receptors. Here the radiosynthesis of radiotracers developed for both types of receptors are reviewed with a highlight on the radiopharmaceuticals used or evaluated in humans. At first, radiotracers were developed for ionotropic N-methyl-d-aspartate receptors without any success to obtain radiopharmaceuticals useable for clinical or even preclinical positron emission tomography (PET) imaging purposes. Some compounds were radiolabelled and evaluated for α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptors without any successful results. The recent development of radiotracers for metabotropic glutamate receptors was more efficient because radiopharmaceuticals are currently evaluated or used in clinical trials to study the mGluR1, mGluR2 or mGluR5 receptors by PET. Although the majority of the radiotracers were classically labelled with carbon-11 by O- or N-[(11) C]-methylation or with fluorine-18 nucleophilic substitution of aromatic nitro or halogeno precursors using krypofix 2.2.2/potassium [(18) F]fluoride complex, some radiosyntheses were performed with recent radiolabelling reactions like the use of iodionium salt for [(18) F]-labelling. Copyright © 2013 John Wiley & Sons, Ltd.
Current developments in the treatment of early-stage classical Hodgkin lymphoma.
Borchmann, Sven; von Tresckow, Bastian; Engert, Andreas
2016-09-01
After presenting the current treatment recommendations for early-stage Hodgkin lymphoma, we give an overview on recently published clinical trials in this setting. Furthermore, the potential influence of current trials on the treatment of early-stage Hodgkin lymphoma and integration of newly emerging drugs into treatment protocols will be discussed. Trials attempting treatment de-escalation and omission of radiotherapy on the basis of early interim PET-scans have been disappointing so far, but results of some large trials employing this strategy are still awaited. In contrast, a more defensive strategy of starting treatment with less aggressive doxorubicine, bleomycin, vinblastine, dacarbazine (ABVD) chemotherapy and intensifying treatment in early interim PET-positive patients has shown encouraging results. New drugs such as brentuximab vedotin and immune checkpoint inhibitors have shown promising results in relapsed and refractory Hodgkin lymphoma. Clinical trials of brentuximab vedotin in early-stage Hodgkin lymphoma have been initiated. Additionally, biomarker-based treatment de-escalation might be a possible route for future improvements. The challenge for future clinical research in early-stage Hodgkin lymphoma is to continue to cure the majority of patients with first-line treatment while reducing long-term toxicity. New strategies to achieve that goal are currently being developed and will further refine treatment of early-stage Hodgkin lymphoma.
NASA Astrophysics Data System (ADS)
Hippe, K.; Kober, F.; Zeilinger, G.; Ivy-Ochs, S.; Kubik, P.; Maden, C.; Wieler, R.
2010-12-01
The high Altiplano plateau is the most prominent element of the Central Andes, separating the Andean Cordilleras between 15° to 22° S. It represents a tectonically quiet, intramontane basin with arid to semi-arid climate, low relief and internal drainage. Throughout the late Quaternary regional climate on the Altiplano repeatedly changed between wet and dry conditions [1]. The influence of climate on the plateau evolution during the Pleistocene/Holocene is unclear, however, as data on erosion processes and rates on the Altiplano are sparse. Here, we present a multiple-nuclide study investigating surface denudation at the eastern Altiplano of Bolivia (16°-17° S) on millennial and longer timescales. The aim is a better understanding of the complex feedback between climate, tectonics and geomorphology on the topographic evolution of the Andes. Catchment-wide denudation (CWD) rates are provided for a 150 km NW-SE transect along the Altiplano edge based on the analyses of cosmogenic 10Be, 26Al, 21Ne and in-situ 14C in river-borne sediment. Single nuclide CWD rates obtained for 10Be, 26Al and 21Ne are similar for all three nuclides and on the order of 3-37 mm/ka. Thus, the calculated denudation rates provide an averaged denudation history dating back at least to the middle Pleistocene. Denudation rates correlate positively with the mean basin hillslope, which is mainly controlled by basin lithology. For most catchments both, the 26Al/10Be ratios and the 21Ne/10Be ratios indicate a complex erosion/exposure history with probably several periods of sediment storage and burial/shielding totalling ~0.5 - 1.2 Ma. Local geomorphology featuring low slopes and low relief, small terraces and local floodplains also suggests that sediment transport might have been periodically ineffective. Concentrations of in-situ produced short-lived 14C are significantly lower than expected from the concentrations of the long-lived and stable cosmogenic nuclides. This would indicate a 30-40 fold increase in denudation rates since ~3000 years, which appears rather unlikely. Hence, the measured in-situ 14C concentrations may actually reflect sediment storage. Partial sediment shielding at ~80-150 cm depth is plausible from field evidence. Due to the fast decay of 14C, such shielding would result in a drop of the 14C concentration from saturation to the measured values already after several 1000 years. Nevertheless, other explanations as incomplete sediment mixing also have to be taken into account. Interestingly, our CWD long-term data agree well with short-term sediment yield data from the Altiplano (5.6-48 mm/ka) [2]. This suggests an overall uniformity in erosional processes and rates throughout the late Quaternary. The agreement between single nuclide denudation rates, despite the complex storage history, also argues for rather long-term steady-state conditions and highlights the insensitivity of long-lived cosmogenic nuclides to low amplitude, short-term variations in climate. References: [1] Plazcek et al. (2006), GSA Bulletin 118, 515-532, [2] Guyot et al. (1992), Lake Titicaca 113-119.
Selected PET radiomic features remain the same.
Tsujikawa, Tetsuya; Tsuyoshi, Hideaki; Kanno, Masafumi; Yamada, Shizuka; Kobayashi, Masato; Narita, Norihiko; Kimura, Hirohiko; Fujieda, Shigeharu; Yoshida, Yoshio; Okazawa, Hidehiko
2018-04-17
We investigated whether PET radiomic features are affected by differences in the scanner, scan protocol, and lesion location using 18 F-FDG PET/CT and PET/MR scans. SUV, TMR, skewness, kurtosis, entropy, and homogeneity strongly correlated between PET/CT and PET/MR images. SUVs were significantly higher on PET/MR 0-2 min and PET/MR 0-10 min than on PET/CT in gynecological cancer ( p = 0.008 and 0.008, respectively), whereas no significant difference was observed between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images in oral cavity/oropharyngeal cancer. TMRs on PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min increased in this order in gynecological cancer and oral cavity/oropharyngeal cancer. In contrast to conventional and histogram indices, 4 textural features (entropy, homogeneity, SRE, and LRE) were not significantly different between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images. 18 F-FDG PET radiomic features strongly correlated between PET/CT and PET/MR images. Dixon-based attenuation correction on PET/MR images underestimated tumor tracer uptake more significantly in oral cavity/oropharyngeal cancer than in gynecological cancer. 18 F-FDG PET textural features were affected less by differences in the scanner and scan protocol than conventional and histogram features, possibly due to the resampling process using a medium bin width. Eight patients with gynecological cancer and 7 with oral cavity/oropharyngeal cancer underwent a whole-body 18 F-FDG PET/CT scan and regional PET/MR scan in one day. PET/MR scans were performed for 10 minutes in the list mode, and PET/CT and 0-2 min and 0-10 min PET/MR images were reconstructed. The standardized uptake value (SUV), tumor-to-muscle SUV ratio (TMR), skewness, kurtosis, entropy, homogeneity, short-run emphasis (SRE), and long-run emphasis (LRE) were compared between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images.
Notre Dame Nuclear Database: A New Chart of Nuclides
NASA Astrophysics Data System (ADS)
Lee, Kevin; Khouw, Timothy; Fasano, Patrick; Mumpower, Matthew; Aprahamian, Ani
2014-09-01
Nuclear data is critical to research fields from medicine to astrophysics. We are creating a database, the Notre Dame Nuclear Database, which can store theoretical and experimental datasets. We place emphasis on storing metadata and user interaction with the database. Users are able to search in addition to the specific nuclear datum, the author(s), the facility where the measurements were made, the institution of the facility, and device or method/technique used. We also allow users to interact with the database by providing online search, an interactive nuclide chart, and a command line interface. The nuclide chart is a more descriptive version of the periodic table that can be used to visualize nuclear properties such as half-lives and mass. We achieve this by using D3 (Data Driven Documents), HTML, and CSS3 to plot the nuclides and color them accordingly. Search capabilities can be applied dynamically to the chart by using Python to communicate with MySQL, allowing for customization. Users can save the customized chart they create to any image format. These features provide a unique approach for researchers to interface with nuclear data. We report on the current progress of this project and will present a working demo that highlights each aspect of the aforementioned features. This is the first time that all available technologies are put to use to make nuclear data more accessible than ever before in a manner that is much easier and fully detailed. This is a first and we will make it available as open source ware.
Comparison of 18F-FDG PET/CT and PET/MRI in patients with multiple myeloma
Sachpekidis, Christos; Hillengass, Jens; Goldschmidt, Hartmut; Mosebach, Jennifer; Pan, Leyun; Schlemmer, Heinz-Peter; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia
2015-01-01
PET/MRI represents a promising hybrid imaging modality with several potential clinical applications. Although PET/MRI seems highly attractive in the diagnostic approach of multiple myeloma (MM), its role has not yet been evaluated. The aims of this prospective study are to evaluate the feasibility of 18F-FDG PET/MRI in detection of MM lesions, and to investigate the reproducibility of bone marrow lesions detection and quantitative data of 18F-FDG uptake between the functional (PET) component of PET/CT and PET/MRI in MM patients. The study includes 30 MM patients. All patients initially underwent 18F-FDG PET/CT (60 min p.i.), followed by PET/MRI (120 min p.i.). PET/CT and PET/MRI data were assessed and compared based on qualitative (lesion detection) and quantitative (SUV) evaluation. The hybrid PET/MRI system provided good image quality in all cases without artefacts. PET/MRI identified 65 of the 69 lesions, which were detectable with PET/CT (94.2%). Quantitative PET evaluations showed the following mean values in MM lesions: SUVaverage=5.5 and SUVmax=7.9 for PET/CT; SUVaverage=3.9 and SUVmax=5.8 for PET/MRI. Both SUVaverage and SUVmax were significantly higher on PET/CT than on PET/MRI. Spearman correlation analysis demonstrated a strong correlation between both lesional SUVaverage (r=0.744) and lesional SUVmax (r=0.855) values derived from PET/CT and PET/MRI. Regarding detection of myeloma skeletal lesions, PET/MRI exhibited equivalent performance to PET/CT. In terms of tracer uptake quantitation, a significant correlation between the two techniques was demonstrated, despite the statistically significant differences in lesional SUVs between PET/CT and PET/MRI. PMID:26550538
Progress on multi-nuclide AMS of JAEA-AMS-TONO
NASA Astrophysics Data System (ADS)
Saito-Kokubu, Yoko; Matsubara, Akihiro; Miyake, Masayasu; Nishizawa, Akimitsu; Ohwaki, Yoshio; Nishio, Tomohiro; Sanada, Katsuki; Hanaki, Tatsumi
2015-10-01
The JAEA-AMS-TONO (Japan Atomic Energy Agency's Accelerator Mass Spectrometer established at the Tono Geoscience Center) facility has been used for the dating of geological samples. The AMS system is versatile, based on a 5 MV tandem Pelletron-type accelerator. Since its establishment in 1997, the AMS system has been used for measurement of carbon-14 (14C) mainly for 14C dating studies in neotectonics and hydrogeology, in support of JAEA's research on geosphere stability applicable to the long-term isolation of high-level radioactive waste. Results of the measurement of 14C in soils and plants has been applied to the dating of fault activity and volcanism. Development of beryllium-10 (10Be) and aluminum-26 (26Al) AMS systems are now underway to enhance the capability of the multi-nuclide AMS in studies of dating by cosmogenic nuclides. The 10Be-AMS system has already been used for routine measurements in applied studies and improvements of the measurement technique have been made. Now we plan to fine tune the system and perform test measurements to develop the 26Al-AMS system.
Indirect detection of infinite-speed MAS solid-state NMR spectra
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perras, Frédéric A.; Venkatesh, Amrit; Hanrahan, Michael P.
Heavy spin-1/2 nuclides are known to possess very large chemical shift anisotropies that can challenge even the most advanced magic-angle-spinning (MAS) techniques. Wide manifolds of overlapping spinning sidebands and insufficient excitation bandwidths often obfuscate meaningful spectral information and force the use of static, low-resolution solid-state (SS)NMR methods for the characterization of materials. In order to address these issues, we have merged fast-magic-angle-turning (MAT) and dipolar heteronuclear multiple-quantum coherence (D-HMQC) experiments to obtain D-HMQC-MAT pulse sequences which enable the rapid acquisition of 2D SSNMR spectra that correlate isotropic 1H chemical shifts to the indirectly detected isotropic “infinite-MAS” spectra of heavy spin-1/2more » nuclides. Furthermore, for these nuclides, the combination of fast MAS and 1H detection provides a high sensitivity, which rivals the DNP-enhanced ultra-wideline SSNMR. The new pulse sequences were used to determine the Pt coordination environments in a complex mixture of decomposition products of transplatin and in a metal-organic framework with Pt ions coordinated to the linker ligands.« less
Indirect detection of infinite-speed MAS solid-state NMR spectra
Perras, Frédéric A.; Venkatesh, Amrit; Hanrahan, Michael P.; ...
2017-01-18
Heavy spin-1/2 nuclides are known to possess very large chemical shift anisotropies that can challenge even the most advanced magic-angle-spinning (MAS) techniques. Wide manifolds of overlapping spinning sidebands and insufficient excitation bandwidths often obfuscate meaningful spectral information and force the use of static, low-resolution solid-state (SS)NMR methods for the characterization of materials. In order to address these issues, we have merged fast-magic-angle-turning (MAT) and dipolar heteronuclear multiple-quantum coherence (D-HMQC) experiments to obtain D-HMQC-MAT pulse sequences which enable the rapid acquisition of 2D SSNMR spectra that correlate isotropic 1H chemical shifts to the indirectly detected isotropic “infinite-MAS” spectra of heavy spin-1/2more » nuclides. Furthermore, for these nuclides, the combination of fast MAS and 1H detection provides a high sensitivity, which rivals the DNP-enhanced ultra-wideline SSNMR. The new pulse sequences were used to determine the Pt coordination environments in a complex mixture of decomposition products of transplatin and in a metal-organic framework with Pt ions coordinated to the linker ligands.« less
Application of gaseous core reactors for transmutation of nuclear waste
NASA Technical Reports Server (NTRS)
Schnitzler, B. G.; Paternoster, R. R.; Schneider, R. T.
1976-01-01
An acceptable management scheme for high-level radioactive waste is vital to the nuclear industry. The hazard potential of the trans-uranic actinides and of key fission products is high due to their nuclear activity and/or chemical toxicity. Of particular concern are the very long-lived nuclides whose hazard potential remains high for hundreds of thousands of years. Neutron induced transmutation offers a promising technique for the treatment of problem wastes. Transmutation is unique as a waste management scheme in that it offers the potential for "destruction" of the hazardous nuclides by conversion to non-hazardous or more manageable nuclides. The transmutation potential of a thermal spectrum uranium hexafluoride fueled cavity reactor was examined. Initial studies focused on a heavy water moderated cavity reactor fueled with 5% enriched U-235-F6 and operating with an average thermal flux of 6 times 10 to the 14th power neutrons/sq cm-sec. The isotopes considered for transmutation were I-129, Am-241, Am-242m, Am-243, Cm-243, Cm-244, Cm-245, and Cm-246.
Indirect detection of infinite-speed MAS solid-state NMR spectra
NASA Astrophysics Data System (ADS)
Perras, Frédéric A.; Venkatesh, Amrit; Hanrahan, Michael P.; Goh, Tian Wei; Huang, Wenyu; Rossini, Aaron J.; Pruski, Marek
2017-03-01
Heavy spin-1/2 nuclides are known to possess very large chemical shift anisotropies that can challenge even the most advanced magic-angle-spinning (MAS) techniques. Wide manifolds of overlapping spinning sidebands and insufficient excitation bandwidths often obfuscate meaningful spectral information and force the use of static, low-resolution solid-state (SS)NMR methods for the characterization of materials. To address these issues, we have merged fast-magic-angle-turning (MAT) and dipolar heteronuclear multiple-quantum coherence (D-HMQC) experiments to obtain D-HMQC-MAT pulse sequences which enable the rapid acquisition of 2D SSNMR spectra that correlate isotropic 1H chemical shifts to the indirectly detected isotropic "infinite-MAS" spectra of heavy spin-1/2 nuclides. For these nuclides, the combination of fast MAS and 1H detection provides a high sensitivity, which rivals the DNP-enhanced ultra-wideline SSNMR. The new pulse sequences were used to determine the Pt coordination environments in a complex mixture of decomposition products of transplatin and in a metal-organic framework with Pt ions coordinated to the linker ligands.
Neutron Capture and the Antineutrino Yield from Nuclear Reactors.
Huber, Patrick; Jaffke, Patrick
2016-03-25
We identify a new, flux-dependent correction to the antineutrino spectrum as produced in nuclear reactors. The abundance of certain nuclides, whose decay chains produce antineutrinos above the threshold for inverse beta decay, has a nonlinear dependence on the neutron flux, unlike the vast majority of antineutrino producing nuclides, whose decay rate is directly related to the fission rate. We have identified four of these so-called nonlinear nuclides and determined that they result in an antineutrino excess at low energies below 3.2 MeV, dependent on the reactor thermal neutron flux. We develop an analytic model for the size of the correction and compare it to the results of detailed reactor simulations for various real existing reactors, spanning 3 orders of magnitude in neutron flux. In a typical pressurized water reactor the resulting correction can reach ∼0.9% of the low energy flux which is comparable in size to other, known low-energy corrections from spent nuclear fuel and the nonequilibrium correction. For naval reactors the nonlinear correction may reach the 5% level by the end of cycle.
CLASSiC: Cherenkov light detection with silicon carbide
NASA Astrophysics Data System (ADS)
Adriani, Oscar; Albergo, Sebastiano; D'Alessandro, Raffaello; Lenzi, Piergiulio; Sciuto, Antonella; Starodubtsev, Oleksandr; Tricomi, Alessia
2017-02-01
We present the CLASSiC R&D for the development of a silicon carbide (SiC) based avalanche photodiode for the detection of Cherenkov light. SiC is a wide-bandgap semiconductor material, which can be used to make photodetectors that are insensitive to visible light. A SiC based light detection device has a peak sensitivity in the deep UV, making it ideal for Cherenkov light. Moreover, the visible blindness allows such a device to disentangle Cherenkov light and scintillation light in all those materials that scintillate above 400 nm. Within CLASSiC, we aim at developing a device with single photon sensitivity, having in mind two main applications. One is the use of the SiC APD in a new generation ToF PET scanner concept, using the Cherenov light emitted by the electrons following 511 keV gamma ray absorption as a time-stamp. Cherenkov is intrinsically faster than scintillation and could provide an unprecedentedly precise time-stamp. The second application concerns the use of SiC APD in a dual readout crystal based hadronic calorimeter, where the Cherenkov component is used to measure the electromagnetic fraction on an event by event basis. We will report on our progress towards the realization of the SiC APD devices, the strategies that are being pursued toward the realization of these devices and the preliminary results on prototypes in terms of spectral response, quantum efficiency, noise figures and multiplication.
NASA Astrophysics Data System (ADS)
Liu, L.; Neretnieks, I.
2006-12-01
ABSTRACT In our conceptualisation, water flows in channels in fractures in fractured rocks such as granites. In the Swedish concept for a repository for spent nuclear fuel the canisters containing the spent fuel are embedded in a buffer in holes below the floor of tunnels. The deposition holes can be intersected by fractures with channels with flowing water. The flow in individual channels is determined by the transmissivity properties of the network of the channels. The flowrate around a deposition hole and in the excavation damaged zone around the tunnels will control the rate of mass transfer of corrosive agents and of escaping nuclides. We call the carrying capacity of the solutes an equivalent flowrate. An escaping nuclide will reach the flowing water in the channel and be transported further into the channel network, mixing with water from other channels at some channel intersections and dividing into several channels at other intersection. In order to follow a nuclide from any leaking canister to the effluent points at the ground surface we have integrated our channel network model CHAN3D with our near field mass transfer model NUCTRAN. The NUCTRAN code, based on a compartment model can calculate the release of nuclides from a defective canister through different pathways into the near field of a repository from the local flowrates in the channels near the deposition hole obtained from CHAN3D. The network model CHAN3D uses observed transmissivity distributions and flowing fracture frequencies in boreholes to set up the 3-dimensional network of stochastic fractures. Deterministic fracture zones are described as such with their hydraulic, properties, sizes, locations and extensions. When available, information on fracture length distributions e.g. power law distributions and correlations between sizes and transmissivities are included in the network model. Once flowrates in all channels in the network have been calculated all equivalent flowrates for all canister positions can be calculated. The rate of transport of corrosive agents to and the releases of nuclides from any damaged canister are then calculated. For any given canister location the channel network model is then used to calculate the paths of the nuclides from the canister through the network by particle tracking. A large number of particles are released one by one from the canister and followed from one channel intersection to the next. A mixing rule is used at an intersection to decide which exit the particle takes. We mostly assume full mixing at intersections. The residence time and the ratio of flow wetted surface to flowrate along every path the particles traverse is summed. This information is sufficient to determine the residence time distribution (RTD) of the nuclides along that path also when they are subject to retardation by surface sorption and matrix diffusion. Actually this information is also sufficient to determine the RTD of arbitrary length decay chains subject to some minor (unimportant) simplifying assumptions. In this paper, we discuss in detail the coupling concept of how to integrate the near and far field models, together with the method of how to include transmissive fractures following a power law length distribution and fracture zones into CHAN3D in order to significantly decrease the computer time without loss of important features of the far field. The simulation results regarding a hypothetical repository located at the Forsmark area, Sweden, are also presented and discussed. Our study suggests that the integrated model can be used as an efficient tool to simulate the release of nuclides, including decay chains, from a repository and the transport to recipients.
NASA Astrophysics Data System (ADS)
Pecha, Petr; Pechova, Emilie
2014-06-01
This article focuses on derivation of an effective algorithm for the fast estimation of cloudshine doses/dose rates induced by a large mixture of radionuclides discharged into the atmosphere. A certain special modification of the classical Gaussian plume approach is proposed for approximation of the near-field dispersion problem. Specifically, the accidental radioactivity release is subdivided into consecutive one-hour Gaussian segments, each driven by a short-term meteorological forecast for the respective hours. Determination of the physical quantity of photon fluence rate from an ambient cloud irradiation is coupled to a special decomposition of the Gaussian plume shape into the equivalent virtual elliptic disks. It facilitates solution of the formerly used time-consuming 3-D integration and provides advantages with regard to acceleration of the computational process on a local scale. An optimal choice of integration limit is adopted on the basis of the mean free path of γ-photons in the air. An efficient approach is introduced for treatment of a wide range of energetic spectrum of the emitted photons when the usual multi-nuclide approach is replaced by a new multi-group scheme. The algorithm is capable of generating the radiological responses in a large net of spatial nodes. It predetermines the proposed procedure such as a proper tool for online data assimilation analysis in the near-field areas. A specific technique for numerical integration is verified on the basis of comparison with a partial analytical solution. Convergence of the finite cloud approximation to the tabulated semi-infinite cloud values for dose conversion factors was validated.
Wiesmüller, Marco; Quick, Harald H; Navalpakkam, Bharath; Lell, Michael M; Uder, Michael; Ritt, Philipp; Schmidt, Daniela; Beck, Michael; Kuwert, Torsten; von Gall, Carl C
2013-01-01
PET/MR hybrid scanners have recently been introduced, but not yet validated. The aim of this study was to compare the PET components of a PET/CT hybrid system and of a simultaneous whole-body PET/MR hybrid system with regard to reproducibility of lesion detection and quantitation of tracer uptake. A total of 46 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 88 min later a second scan using a hybrid PET/MR system. The radioactive tracers used were (18)F-deoxyglucose (FDG), (18)F-ethylcholine (FEC) and (68)Ga-DOTATATE (Ga-DOTATATE). The PET images from PET/CT (PET(CT)) and from PET/MR (PET(MR)) were analysed for tracer-positive lesions. Regional tracer uptake in these foci was quantified using volumes of interest, and maximal and average standardized uptake values (SUV(max) and SUV(avg), respectively) were calculated. Of the 46 patients, 43 were eligible for comparison and statistical analysis. All lesions except one identified by PET(CT) were identified by PET(MR) (99.2 %). In 38 patients (88.4 %), the same number of foci were identified by PET(CT) and by PET(MR). In four patients, more lesions were identified by PET(MR) than by PET(CT), in one patient PET(CT) revealed an additional focus compared to PET(MR). The mean SUV(max) and SUV(avg) of all lesions determined by PET(MR) were by 21 % and 11 % lower, respectively, than the values determined by PET(CT) (p < 0.05), and a strong correlation between these variables was identified (Spearman rho 0.835; p < 0.01). PET/MR showed equivalent performance in terms of qualitative lesion detection to PET/CT. The differences demonstrated in quantitation of tracer uptake between PET(CT) and PET(MR) were minor, but statistically significant. Nevertheless, a more detailed study of the quantitative accuracy of PET(MR) and the factors governing it is needed to ultimately assess its accuracy in measuring tissue tracer concentrations.
Pinilla, I; Gómez-León, N; Del Campo-Del Val, L; Hernandez-Maraver, D; Rodríguez-Vigil, B; Jover-Díaz, R; Coya, J
2011-10-01
The aim of this paper was to compare the accuracy of contrast-enhanced computed tomography (CT), positron emission tomography (PET), unenhanced low-dose PET/CT (LD-PET/CT) and full-dose enhanced PET/CT (FD-PET/CT) for the initial staging of lymphoma. One hundred and one lymphoma patients were examined by [18F]FDG-PET/CT including unenhanced low-dose CT and enhanced full-dose CT. Each modality of PET/CT was evaluated by a nuclear medicine physician and a radiologist unaware of the other modality, while the CT and PET images were interpreted separately by another independent radiologist and nuclear medicine physician respectively. The nodal and extranodal lesions detected by each technique were compared with a reference standard. For nodal assessment, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative LR (LR-) of LD-PET/CT were 97%, 96%, 98%, 95%, 26 and 0.02 respectively, and those of FD-PET/CT were 97%, 97%, 98%, 95%, 36 and 0.02. These results were significantly better than those of PET (sensitivity 82%, specificity 81%, PPV 88%, NPV 72%, LR+ 4.3, LR- 0.21). Likewise, both PET/CT displayed a higher sensitivity, NPV and LR- than CT (91%, 84%, 0.1 respectively). For organ evaluation, both modalities of PET/CT also had significantly better sensitivity and NPV than that of PET (LD-PET/CT: sensitivity 92%, NPV 90%; FD-PET/CT sensitivity 94%, NPV 92%; PET: sensitivity 70%, NPV 69%). The sensitivity, specificity, PPV and NPV for bone marrow involvement were 29%, 84%, 45% and 72% respectively for PET, and 29%, 90%, 56%, and 74% for both, LD-PET/CT, and FD-PET/CT. No significant differences were found between LD-PET/CT and FD-PET/CT, but FD-PET/CT detected important incidental findings in 5.9% of patients. PET/CT is an accurate technique for the initial staging of lymphomas without significant differences between LD-PET/CT and FD-PET/CT. FD-PET/CT detects relevant incidental findings that are missed on LD-PET/CT.
The Petit Rat (pet/pet), a New Semilethal Mutant Dwarf Rat with Thymic and Testicular Anomalies
Chiba, Junko; Suzuki, Katsushi; Suzuki, Hiroetsu
2008-01-01
The petit rat (pet/pet) is a recently discovered semilethal mutant dwarf. The neonatal pet/pet rats had a low body weight and small thymus and testis. During the first 3 d after birth, 50% of the male and 80% of the female pet/pet pups were lost or found dead. Surviving pet/pet rats showed marked retardation of postnatal growth, and their body weights were 41% (female rats) and 32% (male rats) of those of normal rats at the adult stage. The pet/pet rats exhibited proportional dwarfism, and their longitudinal bones were shorter than those of controls without skeletal malformations. Most organs of male pet/pet rats, especially the thymus, testis, adipose tissue surrounding the kidney, and accessory sex organs, weighed markedly less at 140 d of age than did those of their normal counterparts. The thymus of pet/pet rats was small with abnormal thymic follicles. Testes from pet/pet rats exhibited 2 patterns of abnormal histology. Spermatogenesis was present in testes that were only slightly anomalous, but the seminiferous tubules were reduced in diameter. In severely affected testes, most of the seminiferous tubules showed degeneration, and interstitial tissue was increased. Plasma growth hormone concentrations did not differ between pet/pet and normal male rats. The dwarf phenotype of pet/pet rats was inherited as an autosomal recessive trait. These results indicate that the pet/pet rat has a semilethal growth-hormone-independent dwarf phenotype that is accompanied by thymic and testicular anomalies and low birth weight. PMID:19149412
Downes, Martin J; Devitt, Catherine; Downes, Marie T; More, Simon J
2017-01-01
Pet cat and dog obesity contributes to increased risk of several diseases, including cancer and diabetes mellitus as well as a worsening of orthopaedic problems, and a reduction in survival rate. This study aims to develop a better understanding of cat and dog owners' self-reported beliefs and factors that influence owner behaviour around feeding and exercising their pet cat or dog, as there is a lack of in-depth understanding in this area. Seven focus group discussions, with 43 pet owners in total, were conducted. Pet owners often reported a perceived a low level of control over feeding; often undermined by other people feeding of their pet, their pets begging for food, and their pets attitude towards food. Treats were used in the absence of owner control over pet begging and emotional attachment, and to influence pet behaviour. The majority of participants had positive attitudes to pet exercise, which could be related to pet specific requirements, especially differences in cats and dogs. There were some negative experiences of stress associated with dog walking and fears over aggressive confrontations with other dogs. Feeding one's pet is influenced by beliefs about pet specific needs, pet food and pet health, pet owners' perceived control over feeding, and the implications for the pet owner. Pet exercise is influenced by beliefs about pet specific exercise needs, and the implications of exercising one's pet for the pet owner. Understanding owner behaviours on feeding and exercise allows for a more targeted approach to preventing and treating pet obesity.
Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.
Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim
2018-02-01
The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.
The petit rat (pet/pet), a new semilethal mutant dwarf rat with thymic and testicular anomalies.
Chiba, Junko; Suzuki, Katsushi; Suzuki, Hiroetsu
2008-12-01
The petit rat (pet/pet) is a recently discovered semilethal mutant dwarf. The neonatal pet/pet rats had a low body weight and small thymus and testis. During the first 3 d after birth, 50% of the male and 80% of the female pet/pet pups were lost or found dead. Surviving pet/pet rats showed marked retardation of postnatal growth, and their body weights were 41% (female rats) and 32% (male rats) of those of normal rats at the adult stage. The pet/pet rats exhibited proportional dwarfism, and their longitudinal bones were shorter than those of controls without skeletal malformations. Most organs of male pet/pet rats, especially the thymus, testis, adipose tissue surrounding the kidney, and accessory sex organs, weighed markedly less at 140 d of age than did those of their normal counterparts. The thymus of pet/pet rats was small with abnormal thymic follicles. Testes from pet/pet rats exhibited 2 patterns of abnormal histology. Spermatogenesis was present in testes that were only slightly anomalous, but the seminiferous tubules were reduced in diameter. In severely affected testes, most of the seminiferous tubules showed degeneration, and interstitial tissue was increased. Plasma growth hormone concentrations did not differ between pet/pet and normal male rats. The dwarf phenotype of pet/pet rats was inherited as an autosomal recessive trait. These results indicate that the pet/pet rat has a semilethal growth-hormone-independent dwarf phenotype that is accompanied by thymic and testicular anomalies and low birth weight.
Pet Problems at Home: Pet Problems in the Community.
ERIC Educational Resources Information Center
Soltow, Willow
1984-01-01
Discusses problems of pets in the community, examining the community's role related to disruptive pets and pet overpopulation. Also discusses pet problems at home, offering advice on selecting a pet, meeting a pet's needs, and disciplining pets. Includes a list of books, films/filmstrips, teaching materials, and various instructional strategies.…
Simulating CRN derived erosion rates in a transient Andean catchment using the TTLEM model
NASA Astrophysics Data System (ADS)
Campforts, Benjamin; Vanacker, Veerle; Herman, Frédéric; Schwanghart, Wolfgang; Tenrorio Poma, Gustavo; Govers, Gerard
2017-04-01
Assessing the impact of mountain building and erosion on the earth surface is key to reconstruct and predict terrestrial landscape evolution. Landscape evolution models (LEMs) are an essential tool in this research effort as they allow to integrate our growing understanding of physical processes governing erosion and transport of mass across the surface. The recent development of several LEMs opens up new areas of research in landscape evolution. Here, we want to seize this opportunity by answering a fundamental research question: does a model designed to simulate landscape evolution over geological timescales allows to simulate spatially varying erosion rates at a millennial timescale? We selected the highly transient Paute catchment in the Southeastern Ecuadorian Andes as a study area. We found that our model (TTLEM) is capable to better explain the spatial patterns of ca. 30 Cosmogenic Radio Nuclide (CRN) derived catchment wide erosion rates in comparison to a classical, statistical approach. Thus, the use of process-based landscape evolution models may not only be of great help to understand long-term landscape evolution but also in understanding spatial and temporal variations in sediment fluxes at the millennial time scale.
Lee, Soo Jin; Paeng, Jin Chul; Goo, Jin Mo; Lee, Jeong Min; Cheon, Gi Jeong; Lee, Dong Soo; Chung, June-Key; Kang, Keon Wook
2017-04-01
The purpose of this study was to compare quantitative indexes for fluorine-18 fluorodeoxyglucose uptake and metabolic volume between PET/MRI and PET/CT. Sixty-six patients with solid tumors (32 with lung cancer and 34 with pancreatic cancer) who underwent sequential fluorine-18 fluorodeoxyglucose PET/MRI and PET/CT were retrospectively enrolled. On PET images, maximum and peak standardized uptake values (SUVmax and SUVpeak, respectively), and maximum tumor-to-liver ratio (TLRmax) were measured. Metabolic tumor volume (MTV) and total-lesion glycolysis (TLG) with margin thresholds of 50% SUVmax and SUV 2.5 (MTV50%, MTV2.5; TLG50%, TLG2.5, respectively) were compared between PET/MRI and PET/CT, with patients classified into two groups using imaging protocol (the PET/MRI-first and PET/CT-first groups). There were significant correlations of all tested indexes between PET/MRI and PET/CT (r=0.867-0.987, P<0.001). SUVmax and SUVpeak were lower on PET/MRI regardless of imaging protocol (P<0.001 in the PET/MRI-first group). In contrast, TLRmax exhibited reverse results between the PET/MRI-first and PET/CT-first groups. MTV50% and TLG values varied between PET/MRI and PET/CT, as well as between the PET/MRI-first and PET/CT-first groups. However, MTV2.5 was relatively robust against imaging protocol and modality. There are significant correlations of the quantitative indexes between PET/MRI and PET/CT. However, uptake indexes of SUVmax and SUVpeak are lower on PET/MRI than on PET/CT, and volumetric indexes of MTV50% and TLG values also exhibited significant differences. It may be suggested that TLRmax and MTV2.5 are relatively more appropriate indexes than others when PET/MRI and PET/CT are used interchangeably.
... PET - chest; PET - lung; PET - tumor imaging; PET/CT - lung; Solitary pulmonary nodule - PET ... minutes. PET scans are performed along with a CT scan. This is because the combined information from ...
Positron Emission Tomography (PET)
DOE R&D Accomplishments Database
Welch, M. J.
1990-01-01
Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.
Clavijo, A; Lin, M; Riva, J; Mallory, M; Lin, F; Zhou, E M
2001-02-01
The sequence encoding a truncated E2 glycoprotein of the Alfort/187 strain of classical swine fever virus (CSFV) was expressed in Escherichia coli using the pET expression system and the recombinant product purified by Ni-NTA agarose affinity chromatography. The antigenicity of this recombinant protein was demonstrated by immunoblot using anti- CSFV-specific antibodies. A monoclonal antibody was produced against the truncated E2 protein and used as competitor in an ELISA for the detection of antibodies to CSFV. Specific antibodies were demonstrated by competitive ELISA (C-ELISA) as early as 21 days post-infection (dpi) in experimentally infected pigs. Seroconversion was demonstrated by C-ELISA and neutralising peroxidase-linked assay (NPLA) in all infected animals by 4 weeks. No cross-reaction with antibodies to bovine viral diarrhoea virus (BVDV) was seen in the C-ELISA using sera from experimentally infected pigs. The C-ELISA is not intended as a substitute for the NPLA. However, it is expected it will be useful for monitoring and prevalence studies. It will also assist in testing a large number of samples in the event of an outbreak. Copyright 2001 Harcourt Publishers Ltd.
Calculated half-lives and kinetic energies for spontaneous emission of heavy ions from nuclei
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poenaru, D.N.; Greiner, W.; Depta, K.
The most probable decays by spontaneous emission of heavy ions are listed for nuclides with Z = 47--106 and total half-lives>1 ..mu..sec. Partial half-lives, branching ratios relative to ..cap alpha.. decay, kinetic energies, and Q values are estimated by using the analytical superasymmetric fission model, a semiempirical formula for those ..cap alpha..-decay lifetimes which have not been measured, and the new Wapstra--Audi mass tables. Numerous ''stable'' nuclides with Z>40 are found to be metastable with respect to the new decay modes. The current experimental status is briefly reviewed.
Nuclide Depletion Capabilities in the Shift Monte Carlo Code
Davidson, Gregory G.; Pandya, Tara M.; Johnson, Seth R.; ...
2017-12-21
A new depletion capability has been developed in the Exnihilo radiation transport code suite. This capability enables massively parallel domain-decomposed coupling between the Shift continuous-energy Monte Carlo solver and the nuclide depletion solvers in ORIGEN to perform high-performance Monte Carlo depletion calculations. This paper describes this new depletion capability and discusses its various features, including a multi-level parallel decomposition, high-order transport-depletion coupling, and energy-integrated power renormalization. Several test problems are presented to validate the new capability against other Monte Carlo depletion codes, and the parallel performance of the new capability is analyzed.
Bridging the timescales between thermochronological and cosmogenic nuclide data
NASA Astrophysics Data System (ADS)
Glotzbach, Christoph
2015-04-01
Reconstructing the evolution of Earth's landscape is a key to understand its future evolution and to identify the driving forces that shape Earth's surface. Cosmogenic nuclide and thermochronological methods are routinely used to quantify Earth surface processes over 102-104 yr and 106-107 yr, respectively (e.g. Lal 1991; Reiners and Ehlers 2005; von Blanckenburg 2006). A comparison of the rates of surface processes derived from these methods is, however, hampered by the large difference in their timescales. For instance, a constant erosion rate of 0.1 mm/yr yield an apatite (U-Th)/He age of ~24 Ma and a 10Be age of ~6 ka, respectively. Analytical methods that bridge this time gap are on the way, but are not yet fully established (e.g. Herman et al. 2010). A ready to use alternative are river profiles, which record the regional uplift history over 102-107 yr (e.g. Pritchard et al. 2009). Changes in uplift are retained in knickzones that propagate with a distinct velocity upstream, and therefore the time of an uplift event can be estimated. Here I present an integrative inverse modelling approach to simultaneously reconstruct river profiles, model thermochronological and cosmogenic nuclide data and to derive robust information about landscape evolution over thousands to millions of years. An efficient inversion routine is used to solve the forward problem and find the best uplift history and erosional parameters that reproduce the observed data. I test the performance of the algorithm by inverting a synthetic dataset and a dataset from the Sila massif (Italy). Results show that even complicated uplift histories can be reliably retrieved by the combined interpretation of river profiles, thermochronological and cosmogenic nuclide data. References Gallagher, K., Brown, R. & Johnson, C. (1998): Fission track analysis and its applications to geological problems. - Annu. Rev. Earth Planet., 26: 519-572. Herman, F., Rhodes, E.J., Braun, J. & Heiniger, L. (2010): Uniform erosion rates and relief amplitude during glacial cycles in the Southern Alps of New Zealand, as revealed from OSL-thermochronology. - Earth Planet. Sci. Lett., 297: 183-189. Lal, D. (1991): Cosmic ray labeling of erosion surfaces: in situ nuclide production rates and erosion models. - Earth Planet. Sci. Lett. 104: 424-439. Pritchard, D., Roberts, G.G., White, N.J. & Richardson, C.N. (2009): Uplift histories from river profiles. - Geophys. Res. Lett., 36, L24301, doi:10.1029/2009GL040928. Reiners, P.W. & Ehlers, T.A. (2005): Low-temperature Thermochronology: Techniques, Interpretations, and Applications. - Rev. Mineral. Geochem., 58. Von Blanckenburg, F. (2006): The control mechanisms of erosion and weathering at basin scale from cosmogenic nuclides in river sediment. - Earth Planet. Sci. Lett., 242: 462-479.
NASA Astrophysics Data System (ADS)
Pelt, E.; Chabaux, F. J.; Innocent, C.; Ghaleb, B.
2009-12-01
Analysis of U-series nuclides in weathering profiles is developed today for constraining time scale of soil and weathering profile formation (e.g., Chabaux et al., 2008). These studies require the understanding of U-series nuclides sources and fractionation in weathering systems. For most of these studies the impact of aeolian inputs on U-series nuclides in soils is usually neglected. Here, we propose to discuss such an assumption, i.e., to evaluate the impact of dust deposition on U-series nuclides in soils, by working on present and paleo-soils collected on the Mount Cameroon volcano. Recent Sr, Nd, Pb isotopic analyses performed on these samples have indeed documented significant inputs of Saharan dusts in these soils (Dia et al., 2006). We have therefore analyzed 238U-234U-230Th nuclides in the same samples. Comparison of U-Th isotopic data with Sr-Nd-Pb isotopic data indicates a significant impact of the dust input on the U and Th budget of the soils, around 10% for both U and Th. Using Sr-Nd-Pb isotopic data of Saharan dusts given by Dia et al. (2006) we estimate U-Th concentrations and U-Th isotope ratios of dusts compatible with U-Th data obtained on Saharan dusts collected in Barbados (Rydell H.S. and Prospero J.M., 1972). However, the variations of U/Th ratios along the weathering profiles cannot be explained by a simple mixing scenario between material from basalt and from the defined atmospheric dust pool. A secondary uranium migration associated with chemical weathering has affected the weathering profiles. Mass balance calculation suggests that U in soils from Mount Cameroon is affected at the same order of magnitude by both chemical migration and dust accretion. Nevertheless, the Mount Cameroon is a limit case were large dust inputs from continental crust of Sahara contaminate basaltic terrain from Mount Cameroon volcano. Therefore, this study suggests that in other contexts were dust inputs are lower, or the bedrocks more concentrated in U and Th, the dust contribution will not significantly influence U-series dating. Chabaux F., Bourdon B., Riotte J. (2008). U-series Geochemistry in weathering profiles, river waters and lakes. Radioactivity in the Environment, 13, 49-104. Dia A., Chauvel C., Bulourde M. and Gérard M. (2006). Eolian contribution to soils on Mount Cameroon: Isotopic and trace element records. Chem. Geol. 226, 232-252. Rydell H.S. and Prospero J.M. (1972). Uranium and thorium concentrations in wind-borne Saharan dust over the western equatorial north atlantic ocean. EPSL 14, 397-402.
ChIA-PET2: a versatile and flexible pipeline for ChIA-PET data analysis
Li, Guipeng; Chen, Yang; Snyder, Michael P.; Zhang, Michael Q.
2017-01-01
ChIA-PET2 is a versatile and flexible pipeline for analyzing different types of ChIA-PET data from raw sequencing reads to chromatin loops. ChIA-PET2 integrates all steps required for ChIA-PET data analysis, including linker trimming, read alignment, duplicate removal, peak calling and chromatin loop calling. It supports different kinds of ChIA-PET data generated from different ChIA-PET protocols and also provides quality controls for different steps of ChIA-PET analysis. In addition, ChIA-PET2 can use phased genotype data to call allele-specific chromatin interactions. We applied ChIA-PET2 to different ChIA-PET datasets, demonstrating its significantly improved performance as well as its ability to easily process ChIA-PET raw data. ChIA-PET2 is available at https://github.com/GuipengLi/ChIA-PET2. PMID:27625391
18F-FDG PET/MRI fusion in characterizing pancreatic tumors: comparison to PET/CT.
Tatsumi, Mitsuaki; Isohashi, Kayako; Onishi, Hiromitsu; Hori, Masatoshi; Kim, Tonsok; Higuchi, Ichiro; Inoue, Atsuo; Shimosegawa, Eku; Takeda, Yutaka; Hatazawa, Jun
2011-08-01
To demonstrate that positron emission tomography (PET)/magnetic resonance imaging (MRI) fusion was feasible in characterizing pancreatic tumors (PTs), comparing MRI and computed tomography (CT) as mapping images for fusion with PET as well as fused PET/MRI and PET/CT. We retrospectively reviewed 47 sets of (18)F-fluorodeoxyglucose ((18)F -FDG) PET/CT and MRI examinations to evaluate suspected or known pancreatic cancer. To assess the ability of mapping images for fusion with PET, CT (of PET/CT), T1- and T2-weighted (w) MR images (all non-contrast) were graded regarding the visibility of PT (5-point confidence scale). Fused PET/CT, PET/T1-w or T2-w MR images of the upper abdomen were evaluated to determine whether mapping images provided additional diagnostic information to PET alone (3-point scale). The overall quality of PET/CT or PET/MRI sets in diagnosis was also assessed (3-point scale). These PET/MRI-related scores were compared to PET/CT-related scores and the accuracy in characterizing PTs was compared. Forty-three PTs were visualized on CT or MRI, including 30 with abnormal FDG uptake and 13 without. The confidence score for the visibility of PT was significantly higher on T1-w MRI than CT. The scores for additional diagnostic information to PET and overall quality of each image set in diagnosis were significantly higher on the PET/T1-w MRI set than the PET/CT set. The diagnostic accuracy was higher on PET/T1-w or PET/T2-w MRI (93.0 and 90.7%, respectively) than PET/CT (88.4%), but statistical significance was not obtained. PET/MRI fusion, especially PET with T1-w MRI, was demonstrated to be superior to PET/CT in characterizing PTs, offering better mapping and fusion image quality.
PET/MRI: Where Might It Replace PET/CT?
Ehman, Eric C.; Johnson, Geoffrey B.; Villanueva-Meyer, Javier E.; Cha, Soonmee; Leynes, Andrew Palmera; Larson, Peder Eric Zufall; Hope, Thomas A.
2017-01-01
Simultaneous positron emission tomography and MRI (PET/MRI) is a technology that combines the anatomic and quantitative strengths of MR imaging with physiologic information obtained from PET. PET and computed tomography (PET/ CT) performed in a single scanning session is an established technology already in widespread and accepted use worldwide. Given the higher cost and complexity of operating and interpreting the studies obtained on a PET/MRI system, there has been question as to which patients would benefit most from imaging with PET/MRI versus PET/CT. In this article, we compare PET/MRI with PET/CT, detail the applications for which PET/MRI has shown promise and discuss impediments to future adoption. It is our hope that future work will prove the benefit of PET/MRI to specific groups of patients, initially those in which PET/CT and MRI are already performed, leveraging simultaneity and allowing for greater degrees of multiparametric evaluation. PMID:28370695
Development of a methodology to evaluate material accountability in pyroprocess
NASA Astrophysics Data System (ADS)
Woo, Seungmin
This study investigates the effect of the non-uniform nuclide composition in spent fuel on material accountancy in the pyroprocess. High-fidelity depletion simulations are performed using the Monte Carlo code SERPENT in order to determine nuclide composition as a function of axial and radial position within fuel rods and assemblies, and burnup. For improved accuracy, the simulations use short burnups step (25 days or less), Xe-equilibrium treatment (to avoid oscillations over burnup steps), axial moderator temperature distribution, and 30 axial meshes. Analytical solutions of the simplified depletion equations are built to understand the axial non-uniformity of nuclide composition in spent fuel. The cosine shape of axial neutron flux distribution dominates the axial non-uniformity of the nuclide composition. Combined cross sections and time also generate axial non-uniformity, as the exponential term in the analytical solution consists of the neutron flux, cross section and time. The axial concentration distribution for a nuclide having the small cross section gets steeper than that for another nuclide having the great cross section because the axial flux is weighted by the cross section in the exponential term in the analytical solution. Similarly, the non-uniformity becomes flatter as increasing burnup, because the time term in the exponential increases. Based on the developed numerical recipes and decoupling of the results between the axial distributions and the predetermined representative radial distributions by matching the axial height, the axial and radial composition distributions for representative spent nuclear fuel assemblies, the Type-0, -1, and -2 assemblies after 1, 2, and 3 depletion cycles, is obtained. These data are appropriately modified to depict processing for materials in the head-end process of pyroprocess that is chopping, voloxidation and granulation. The expectation and standard deviation of the Pu-to-244Cm-ratio by the single granule sampling calculated by the central limit theorem and the Geary-Hinkley transformation. Then, the uncertainty propagation through the key-pyroprocess is conducted to analyze the Material Unaccounted For (MUF), which is a random variable defined as a receipt minus a shipment of a process, in the system. The random variable, LOPu, is defined for evaluating the non-detection probability at each Key Measurement Point (KMP) as the original Pu mass minus the Pu mass after a missing scenario. A number of assemblies for the LOPu to be 8 kg is considered in this calculation. The probability of detection for the 8 kg LOPu is evaluated with respect the size of granule and powder using the event tree analysis and the hypothesis testing method. We can observe there are possible cases showing the probability of detection for the 8 kg LOPu less than 95%. In order to enhance the detection rate, a new Material Balance Area (MBA) model is defined for the key-pyroprocess. The probabilities of detection for all spent fuel types based on the new MBA model are greater than 99%. Furthermore, it is observed that the probability of detection significantly increases by increasing granule sample sizes to evaluate the Pu-to-244Cm-ratio before the key-pyroprocess. Based on these observations, even though the Pu material accountability in pyroprocess is affected by the non-uniformity of nuclide composition when the Pu-to-244Cm-ratio method is being applied, that is surmounted by decreasing the uncertainty of measured ratio by increasing sample sizes and modifying the MBAs and KMPs. (Abstract shortened by ProQuest.).
Chiu, Kuo Ping; Wong, Chee-Hong; Chen, Qiongyu; Ariyaratne, Pramila; Ooi, Hong Sain; Wei, Chia-Lin; Sung, Wing-Kin Ken; Ruan, Yijun
2006-08-25
We recently developed the Paired End diTag (PET) strategy for efficient characterization of mammalian transcriptomes and genomes. The paired end nature of short PET sequences derived from long DNA fragments raised a new set of bioinformatics challenges, including how to extract PETs from raw sequence reads, and correctly yet efficiently map PETs to reference genome sequences. To accommodate and streamline data analysis of the large volume PET sequences generated from each PET experiment, an automated PET data process pipeline is desirable. We designed an integrated computation program package, PET-Tool, to automatically process PET sequences and map them to the genome sequences. The Tool was implemented as a web-based application composed of four modules: the Extractor module for PET extraction; the Examiner module for analytic evaluation of PET sequence quality; the Mapper module for locating PET sequences in the genome sequences; and the Project Manager module for data organization. The performance of PET-Tool was evaluated through the analyses of 2.7 million PET sequences. It was demonstrated that PET-Tool is accurate and efficient in extracting PET sequences and removing artifacts from large volume dataset. Using optimized mapping criteria, over 70% of quality PET sequences were mapped specifically to the genome sequences. With a 2.4 GHz LINUX machine, it takes approximately six hours to process one million PETs from extraction to mapping. The speed, accuracy, and comprehensiveness have proved that PET-Tool is an important and useful component in PET experiments, and can be extended to accommodate other related analyses of paired-end sequences. The Tool also provides user-friendly functions for data quality check and system for multi-layer data management.
Iagaru, Andrei; Mittra, Erik; Minamimoto, Ryogo; Jamali, Mehran; Levin, Craig; Quon, Andrew; Gold, Garry; Herfkens, Robert; Vasanawala, Shreyas; Gambhir, Sanjiv Sam; Zaharchuk, Greg
2015-01-01
The recent introduction of hybrid PET/MRI scanners in clinical practice has shown promising initial results for several clinical scenarios. However, the first generation of combined PET/MRI lacks time-of-flight (TOF) technology. Here we report the results of the first patients to be scanned on a completely novel fully integrated PET/MRI scanner with TOF. We analyzed data from patients who underwent a clinically indicated F FDG PET/CT, followed by PET/MRI. Maximum standardized uptake values (SUVmax) were measured from F FDG PET/MRI and F FDG PET/CT for lesions, cerebellum, salivary glands, lungs, aortic arch, liver, spleen, skeletal muscle, and fat. Two experienced radiologists independently reviewed the MR data for image quality. Thirty-six patients (19 men, 17 women, mean [±standard deviation] age of 61 ± 14 years [range: 27-86 years]) with a total of 69 discrete lesions met the inclusion criteria. PET/CT images were acquired at a mean (±standard deviation) of 74 ± 14 minutes (range: 49-100 minutes) after injection of 10 ± 1 mCi (range: 8-12 mCi) of F FDG. PET/MRI scans started at 161 ± 29 minutes (range: 117 - 286 minutes) after the F FDG injection. All lesions identified on PET from PET/CT were also seen on PET from PET/MRI. The mean SUVmax values were higher from PET/MRI than PET/CT for all lesions. No degradation of MR image quality was observed. The data obtained so far using this investigational PET/MR system have shown that the TOF PET system is capable of excellent performance during simultaneous PET/MR with routine pulse sequences. MR imaging was not compromised. Comparison of the PET images from PET/CT and PET/MRI show no loss of image quality for the latter. These results support further investigation of this novel fully integrated TOF PET/MRI instrument.
Modified physiologically equivalent temperature—basics and applications for western European climate
NASA Astrophysics Data System (ADS)
Chen, Yung-Chang; Matzarakis, Andreas
2018-05-01
A new thermal index, the modified physiologically equivalent temperature (mPET) has been developed for universal application in different climate zones. The mPET has been improved against the weaknesses of the original physiologically equivalent temperature (PET) by enhancing evaluation of the humidity and clothing variability. The principles of mPET and differences between original PET and mPET are introduced and discussed in this study. Furthermore, this study has also evidenced the usability of mPET with climatic data in Freiburg, which is located in Western Europe. Comparisons of PET, mPET, and Universal Thermal Climate Index (UTCI) have shown that mPET gives a more realistic estimation of human thermal sensation than the other two thermal indices (PET, UTCI) for the thermal conditions in Freiburg. Additionally, a comparison of physiological parameters between mPET model and PET model (Munich Energy Balance Model for Individual, namely MEMI) is proposed. The core temperatures and skin temperatures of PET model vary more violently to a low temperature during cold stress than the mPET model. It can be regarded as that the mPET model gives a more realistic core temperature and mean skin temperature than the PET model. Statistical regression analysis of mPET based on the air temperature, mean radiant temperature, vapor pressure, and wind speed has been carried out. The R square (0.995) has shown a well co-relationship between human biometeorological factors and mPET. The regression coefficient of each factor represents the influence of the each factor on changing mPET (i.e., ±1 °C of T a = ± 0.54 °C of mPET). The first-order regression has been considered predicting a more realistic estimation of mPET at Freiburg during 2003 than the other higher order regression model, because the predicted mPET from the first-order regression has less difference from mPET calculated from measurement data. Statistic tests recognize that mPET can effectively evaluate the influences of all human biometeorological factors on thermal environments. Moreover, a first-order regression function can also predict the thermal evaluations of the mPET by using human biometeorological factors in Freiburg.
NASA Astrophysics Data System (ADS)
Akif Sarıkaya, M.; Çiner, Attila; Yıldırım, Cengiz
2017-04-01
Cosmogenic surface exposure dating has been applied to date numerous moraines worldwide. The geochronological data obtained from these studies have improved our knowledge on the timing of glaciation and allow us to reconstruct the paleoclimate. Due to the geomorphic complications after deposition, such as degradation, exhumation, bedrock erosion, snow cover and toppling of boulders, several (n>5) large boulder (>1-2 m) samples should be dated to obtain a reliable age distribution. Generally, the ages on a well-preserved moraine surface show unimodal normal distribution. Frequently, erosion, exhumation and boulder toppling are blamed for the younger outliers. On the other hand, although infrequent, older outliers will indicate inherited nuclide concentration from pre-exposure to cosmic radiation. To obtain the true age of a moraine deposit, one needs to collect several samples that not only greatly increases the budget of the project but also is time consuming. To overcome this problem, we developed a new sampling strategy for dating moraine surfaces by cosmogenic nuclides. We collected rock chips (each 20-50 grams) from large boulder (>1 m) tops located on the crest of moraines. Fourteen to 32 boulders were chosen for sampling every 20 m. All rock chips were amalgamated to make one sample. To test the suitability of the method, we also sampled 3 large boulders (>1 m), as it is done classically, from the same surface. The age results from the two Late Pleistocene moraines and one rock glacier surface show no difference in terms of boulder exposure ages. Three 36Cl ages from one single lateral moraine in Çimi Valley of Geyikdaǧ, central Taurus, Turkey, are 11.9±0.9 ka, 14.0±1.1 ka and 11.9±0.9 ka (all ages have no erosion corrections) and yield a mean age of 12.6±0.9 ka, while the amalgamated boulder chips' (ABCs) age is 12.0±0.9 ka. Another well developed terminal moraine (so called Zor Moraine) in the Güneycik Valley of Geyikdaǧ, yielded ages as 4.9±0.4 ka, 7.7±0.6 ka and 3.7±0.3 ka, while the ABCs' age is 6.4±0.6 ka. The rock glacier boulder samples yielded ages of 12.2±0.9 ka, 14.0±1.0 ka and 9.2±0.8 ka, while the rock glacier ABCs' age is 10.7±0.9 ka. These results clearly indicate that the age obtained from ABCs is reliable and can safely replace classical methodology that requires collection of several samples from a moraine surface. The use of ABCs sampling strategy will considerably decrease the time and budget allocated to date a landform. This work was supported by TUBITAK 112Y139 project.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dasgupta-Schubert, N.; Reyes, M.A.
2007-11-15
The predictive accuracy of the generalized liquid drop model (GLDM) formula for alpha-decay half-lives has been investigated in a detailed manner and a variant of the formula with improved coefficients is proposed. The method employs the experimental alpha half-lives of the well-known alpha standards to obtain the coefficients of the analytical formula using the experimental Q{sub {alpha}} values (the DSR-E formula), as well as the finite range droplet model (FRDM) derived Q{sub {alpha}} values (the FRDM-FRDM formula). The predictive accuracy of these formulae was checked against the experimental alpha half-lives of an independent set of nuclei (TEST) that span approximatelymore » the same Z, A region as the standards and possess reliable alpha spectroscopic data, and were found to yield good results for the DSR-E formula but not for the FRDM-FRDM formula. The two formulae were used to obtain the alpha half-lives of superheavy elements (SHE) and heavy nuclides where the relative accuracy was found to be markedly improved for the FRDM-FRDM formula, which corroborates the appropriateness of the FRDM masses and the GLDM prescription for high Z, A nuclides. Further improvement resulted, especially for the FRDM-FRDM formula, after a simple linear optimization over the calculated and experimental half-lives of TEST was used to re-calculate the half-lives of the SHE and heavy nuclides. The advantage of this optimization was that it required no re-calculation of the coefficients of the basic DSR-E or FRDM-FRDM formulae. The half-lives for 324 medium-mass to superheavy alpha decaying nuclides, calculated using these formulae and the comparison with experimental half-lives, are presented.« less
NASA Astrophysics Data System (ADS)
Nichols, K. A.; Johnson, J.; Goehring, B. M.; Balco, G.
2017-12-01
We present a suite of in situ 14C cosmogenic nuclide exposure ages from nunataks at the Lassiter Coast in West Antarctica on the west side of the Weddell Sea Embayment (WSE) to constrain the thinning history of the Ronne-Filchner Ice Shelf. Constraints on past ice extents in the WSE remain relatively understudied, despite the WSE draining 22% of the Antarctic Ice Sheet (AIS). Information lacking includes unambiguous geological evidence for the maximum Last Glacial Maximum (LGM) ice thickness and the timing of subsequent ice retreat in key peripheral locations. Past studies using long-lived cosmogenic nuclides have shown that, due to the cold-based nature of the AIS, inheritance of nuclide concentrations from previous periods of exposure is a common problem. We utilised the cosmogenic nuclide 14C to circumvent the issue of inheritance. The short half-life of 14C means measured concentrations are largely insensitive to inheritance, as relatively short periods of ice cover (20-30 kyr) result in significant 14C decay. Furthermore, samples saturated in 14C will demonstrate that their location was above the maximum LGM thickness of the ice sheet and exposed for at least the past ca. 35 kyr. Preliminary results from four samples indicate elevations between 63 and 360 m above the present-day ice surface elevations were deglaciated between 7 and 6 ka. With little exposed rock above these elevations (ca. 70 m), this may indicate that the locality was entirely covered by ice during the LGM. Additional 14C measurements will form a full elevation transect of samples to decipher the post-LGM thinning history of ice at this location.
The susceptibility of large river basins to orogenic and climatic drivers
NASA Astrophysics Data System (ADS)
Haedke, Hanna; Wittmann, Hella; von Blanckenburg, Friedhelm
2017-04-01
Large rivers are known to buffer pulses in sediment production driven by changes in climate as sediment is transported through lowlands. Our new dataset of in situ cosmogenic nuclide concentration and chemical composition of 62 sandy bedload samples from the world largest rivers integrates over 25% of Earth's terrestrial surface, distributed over a variety of climatic zones across all continents, and represents the millennial-scale denudation rate of the sediment's source area. We can show that these denudation rates do not respond to climatic forcing, but faithfully record orogenic forcing, when analyzed with respective variables representing orogeny (strain rate, relief, bouguer anomaly, free-air anomaly), and climate (runoff, temperature, precipitation) and basin properties (floodplain response time, drainage area). In contrast to this orogenic forcing of denudation rates, elemental bedload chemistry from the fine-grained portion of the same samples correlates with climate-related variables (precipitation, runoff) and floodplain response times. It is also well-known from previous compilations of river-gauged sediment loads that the short-term basin-integrated sediment export is also climatically controlled. The chemical composition of detrital sediment shows a climate control that can originate in the rivers source area, but this signal is likely overprinted during transfer through the lowlands because we also find correlation with floodplain response times. At the same time, cosmogenic nuclides robustly preserve the orogenic forcing of the source area denudation signal through of the floodplain buffer. Conversely, previous global compilations of cosmogenic nuclides in small river basins show the preservation of climate drivers in their analysis, but these are buffered in large lowland rivers. Hence, we can confirm the assumption that cosmogenic nuclides in large rivers are poorly susceptible to climate changes, but are at the same time highly suited to detect changes in orogenic forcing in their paleo sedimentary records.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, B.Y.; Chen, H.H.; Tsai, H.Y.
2015-06-15
Purpose: To identify the radionuclides and quantify the activity of the patient apertures used in a 190-MeV proton beam of wobbling system. Methods: A proton beam of wobbling system in the first proton center in Taiwan, Chang Gung Memorial Hospital at Linkou, was used to bombard the patient apertures. The patient aperture was composed of 60.5 % copper, 39.4 % Zinc, 0.05 % iron, 0.05 % lead. A protable high-purity germanium (HPGe) coaxial detector was used to measure the spectra of the induced nuclides of patient apertures. The analysis of the spectra and the identification of the radionuclides were preliminarilymore » operated by the Nuclide Navigator III Master Library. On the basis of the results by Nuclide Navigator III Master Library, we manually selected the reliable nuclides by the gamma-ray energies, branching ratio, and half life. In the spectra, we can quantify the activity of radionuclides by the Monte Carlo efficiency transfer method. Results: In this study, the radioisotopes activated in patient apertures by the 190-MeV proton beam were divided into two categories. The first category is long half-life radionuclides, such as Co-56 (half life, 77.3 days). Other radionuclides of Cu-60, Cu-61, Cu-62, Cu-66, and Zn-62 have shorter half life. The radionuclide of Cu-60 had the highest activity. From calculation with the efficiency transfer method, the deviations between the computed results and the measured efficiencies were mostly within 10%. Conclusion: To identify the radionuclides and quantify the activity helps us to estimate proper time intervals for cooling the patient apertures. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1C0682)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Welch, M.J.
Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy inmore » PET, and the futures of PET. 22 figs.« less
Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.
Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori
2018-05-01
The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
Simultaneous (68)Ga-DOTA-TOC PET/MRI with gadoxetate disodium in patients with neuroendocrine tumor.
Hope, Thomas A; Pampaloni, Miguel Hernandez; Nakakura, Eric; VanBrocklin, Henry; Slater, James; Jivan, Salma; Aparici, Carina Mari; Yee, Judy; Bergsland, Emily
2015-08-01
To evaluate a simultaneous PET/MRI approach to imaging patients with neuroendocrine tumor using a combination of (68)Ga-DOTA-TOC as a PET contrast agent and gadoxetate disodium as a hepatobiliary MRI contrast agent. Ten patients with neuroendocrine tumor with known or suspected hepatic disease were imaged using a (68)Ga-DOTA-TOC PET/CT immediately followed by a 3.0T time-of-flight PET/MRI, using a combined whole body and liver specific imaging. The presence of lesions and DOTA-TOC avidity were assessed on CT, PET from PET/CT, diffusion weighted imaging, hepatobiliary phase imaging (HBP), and PET from PET/MRI. Maximum standardized uptake values (SUVmax) in hepatic lesions and nodal metastases were compared between PET/CT and PET/MRI, as were detection rates using each imaging approach. A total of 101 hepatic lesions were identified, 47 of which were DOTA-TOC avid and able to be individually measured on both PET/CT and PET/MRI. HBP imaging had a higher sensitivity for detection of hepatic lesions compared to CT or PET (99% vs. 46% and 64%, respectively; p values <0.001). There was a strong correlation between SUVmax of liver lesions obtained with PET/CT compared to PET/MR imaging (Pearson's correlation = 0.91). For nodal disease, CT had a higher sensitivity compared to whole body MRI (p = 0.015), although PET acquired from PET/MRI detected slightly more lesions compared to PET from PET/CT. A simultaneous PET/MRI using both (68)Ga-DOTA-TOC and gadoxetate disodium was successful in whole body staging of patients with neuroendocrine tumor. HBP imaging had an increased detection rate for hepatic metastases.
NASA Astrophysics Data System (ADS)
Canadas, Mario; Embid, Miguel; Lage, Eduardo; Desco, Manuel; Vaquero, Juan José; Perez, José Manuel
2011-02-01
In this work, we compare two commercial positron emission tomography (PET) scanners installed at CIEMAT (Madrid, Spain): the ClearPET and the rPET-1. These systems have significant geometrical differences, such as the axial field of view (110 mm on ClearPET versus 45.6 mm on rPET-1), the configuration of the detectors (whole ring on ClearPET versus one pair of planar blocks on rPET-1) and the use of an axial shift between ClearPET detector modules. We used an assessment procedure that fulfilled the recommendations of the National Electrical Manufacturers Association (NEMA) NU 4-2008 standard. The methodology includes studies of spatial resolution, sensitivity, scatter fraction, count losses and image quality. Our experiments showed a central spatial resolution of 1.5 mm (transaxial), 3.2 mm (axial) for the ClearPET and 1.5 mm (transaxial), 1.6 mm (axial) for the rPET-1, with a small variation across the transverse axis on both scanners ( 1 mm). The absolute sensitivity at the centre of the field of view was 4.7% for the ClearPET and 1.0% for the rPET-1. The peak noise equivalent counting rate for the mouse-sized phantom was 73.4 kcps reached at 0.51 MBq/mL on the ClearPET and 29.2 kcps at 1.35 MBq/mL on the rPET-1. The recovery coefficients measured using the image quality phantom ranged from 0.11 to 0.89 on the ClearPET and from 0.14 to 0.81 on the rPET-1. The overall performance shows that both the ClearPET and the rPET-1 systems are very suitable for preclinical research and imaging of small animals.
Wang, Shao-Bo; Wu, Hu-Bing; Wang, Quan-Shi; Zhou, Wen-Lan; Tian, Ying; Li, Hong-Sheng; Ji, Yun-Hai; Lv, Liang
2015-06-01
It is widely accepted that conventional (18)F-FDG PET/CT (whole-body static (18)F-FDG PET/CT, WB (18)F-FDG PET/CT) has a low detection rate for hepatocellular carcinoma (HCC). We prospectively assessed the role of early dynamic (18)F-FDG PET/CT (ED (18)F-FDG PET/CT) and WB (18)F-FDG PET/CT in detecting HCC, and we quantified the added value of ED (18)F-FDG PET/CT to WB (18)F-FDG PET/CT. Twenty-two patients with 37 HCC tumors (HCCs) who underwent both a liver ED (18)F-FDG PET/CT (performed simultaneously with a 5.5 MBq/kg (18)F-FDG bolus injection and continued for 240 s) and a WB (18)F-FDG PET/CT were enrolled in the study. The WB (18)F-FDG PET/CT and ED (18)F-FDG PET/CT scans were positive in 56.7% (21/37) and 78.4% (29/37) HCCs, respectively (P<0.05). ED (18)F-FDG PET/CT in conjunction with WB (18)F-FDG PET/CT (one-stop (18)F-FDG PET/CT) improved the positive detection rates of WB and ED (18)F-FDG PET/CT alone from 56.7% and 78.4% to 91.9% (34/37) (P<0.001 and P>0.05, respectively). One-stop (18)F-FDG PET/CT appears to be useful to improve WB (18)F-FDG PET/CT for HCC detection. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J
2014-03-01
The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.
Rhoades, Harmony; Winetrobe, Hailey; Rice, Eric
2014-01-01
As many as 25% of homeless persons have pets. To our knowledge, pet ownership has not been studied quantitatively with homeless youth. This study examined pet ownership among 398 homeless youth utilizing two Los Angeles drop-in centers. Twenty-three percent of homeless youth had a pet. The majority of pet owners reported that their pets kept them company and made them feel loved; nearly half reported that their pets made it more difficult to stay in a shelter. Pet owners reported fewer symptoms of depression and loneliness than their non-pet owning peers. Pet ownership was associated with decreased utilization of housing and job-finding services, and decreased likelihood of currently staying in a shelter. These findings elucidate many of the positive benefits of pet ownership for homeless youth, but importantly highlight that pet ownership may negatively impact housing options. Housing and other services must be sensitive to the needs of homeless youth with pets. PMID:24728815
Rhoades, Harmony; Winetrobe, Hailey; Rice, Eric
2015-04-01
As many as 25 % of homeless persons have pets. To our knowledge, pet ownership has not been studied quantitatively with homeless youth. This study examined pet ownership among 398 homeless youth utilizing two Los Angeles drop-in centers. Twenty-three percent of homeless youth had a pet. The majority of pet owners reported that their pets kept them company and made them feel loved; nearly half reported that their pets made it more difficult to stay in a shelter. Pet owners reported fewer symptoms of depression and loneliness than their non-pet owning peers. Pet ownership was associated with decreased utilization of housing and job-finding services, and decreased likelihood of currently staying in a shelter. These findings elucidate many of the positive benefits of pet ownership for homeless youth, but importantly highlight that pet ownership may negatively impact housing options. Housing and other services must be sensitive to the needs of homeless youth with pets.
Sensory analysis of pet foods.
Koppel, Kadri
2014-08-01
Pet food palatability depends first and foremost on the pet and is related to the pet food sensory properties such as aroma, texture and flavor. Sensory analysis of pet foods may be conducted by humans via descriptive or hedonic analysis, pets via acceptance or preference tests, and through a number of instrumental analysis methods. Sensory analysis of pet foods provides additional information on reasons behind palatable and unpalatable foods as pets lack linguistic capabilities. Furthermore, sensory analysis may be combined with other types of information such as personality and environment factors to increase understanding of acceptable pet foods. Most pet food flavor research is proprietary and, thus, there are a limited number of publications available. Funding opportunities for pet food studies would increase research and publications and this would help raise public awareness of pet food related issues. This mini-review addresses current pet food sensory analysis literature and discusses future challenges and possibilities. © 2014 Society of Chemical Industry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nica N.; Nica,N.; Cameron,J.
2012-01-01
Nuclear spectroscopic information for experimentally investigated nuclides of mass 36 (Mg, Al, Si, P, S, Cl, Ar, K, Ca) has been evaluated. The principal sources of the 'adopted levels' presented for nuclides close to the stability line are Endt's evaluations (1990En08, 1978En02). The data sets for reactions and decays, including all available gamma-ray data, are based mostly on the original literature. The {sup 36}Na has been looked for but not yet experimentally detected. There are no data available for the excited states in {sup 36}Al, and for {sup 36}Mg and {sup 36}Ca, only one excited state is known.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fotion, Katherine A.
2016-08-18
The Radionuclide Analysis Kit (RNAK), my team’s most recent nuclide identification software, is entering the testing phase. A question arises: will removing rare nuclides from the software’s library improve its overall performance? An affirmative response indicates fundamental errors in the software’s framework, while a negative response confirms the effectiveness of the software’s key machine learning algorithms. After thorough testing, I found that the performance of RNAK cannot be improved with the library choice effect, thus verifying the effectiveness of RNAK’s algorithms—multiple linear regression, Bayesian network using the Viterbi algorithm, and branch and bound search.
NASA Astrophysics Data System (ADS)
Wolf, R. N.; Atanasov, D.; Blaum, K.; Kreim, S.; Lunney, D.; Manea, V.; Rosenbusch, M.; Schweikhard, L.; Welker, A.; Wienholtz, F.; Zuber, K.
2016-06-01
In-trap decay in ISOLTRAP's radiofrequency quadrupole (RFQ) ion beam cooler and buncher was used to determine the lifetime of short-lived nuclides. After various storage times, the remaining mother nuclides were mass separated from accompanying isobaric contaminations by the multi-reflection time-of-flight mass separator (MR-ToF MS), allowing for a background-free ion counting. A feasibility study with several online measurements shows that the applications of the ISOLTRAP setup can be further extended by exploiting the high resolving power of the MR-ToF MS in combination with in-trap decay and single-ion counting.
Terrestrial and exposure histories of Antarctic meteorites
NASA Technical Reports Server (NTRS)
Nishiizumi, K.
1986-01-01
Records of cosmogenic effects were studied in a large suite of Antarctic meteorites. The cosmogenic nuclide measurements together with cosmic ray track measurements on Antartic meteorites provide information such as exposure age, terrestrial age, size and depth in meteoroid or parent body, influx rate in the past, and pairing. The terrestrail age is the time period between the fall of the meteorite on the Earth and the present. To define terrestrial age, two or more nuclides with different half-lives and possibly noble gases are required. The cosmogenic radionuclides used are C-14, Kr-81, Cl-36, Al-26, Be-10, Mn-53, and K-40.
Study on immobilization and migration of nuclide u in superficial soil of uranium tailings pond
NASA Astrophysics Data System (ADS)
Chang, Zhe; Zhou, Shukui
2017-05-01
The uranium tailings in southern China was used as the object of study to study the fixation and migration characteristics of nuclide U in shallow tailings. The results showed that the precipitation of tailings in the tailings soil was not linearly related to the depth during the acid rain leaching process. Tailings soil in the role of fixatives, when the lime as a fixative, the tailings of different soil uranium in 20 days after the re-precipitation. However, when lime and ammonium phosphate were used as fixing agents, the cumulative precipitation of U had a significant effect, and the migration of uranium was inhibited.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vondy, D.R.; Fowler, T.B.; Cunningham, G.W.
1975-10-01
The computer code block VENTURE, designed to solve multigroup neutronics problems with application of the finite-difference diffusion-theory approximation to neutron transport (or alternatively simple P$sub 1$) in up to three- dimensional geometry is described. A variety of types of problems may be solved: the usual eigenvalue problem, a direct criticality search on the buckling, on a reciprocal velocity absorber (prompt mode), or on nuclide concentrations, or an indirect criticality search on nuclide concentrations, or on dimensions. First- order perturbation analysis capability is available at the macroscopic cross section level. (auth)
EVALUATED NUCLEAR STRUCTURE DATA FILE AND RELATED PRODUCTS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
TULI,J.K.
The Evaluated Nuclear Structure Data File (ENSDF) is a leading resource for the experimental nuclear data. It is maintained and distributed by the National Nuclear Data Center, Brookhaven National Laboratory. The file is mainly contributed to by an international network of evaluators under the auspice of the International Atomic Energy Agency. The ENSDF is updated, generally by mass number, i.e., evaluating together all isobars for a given mass number. If, however, experimental activity in an isobaric chain is limited to a particular nuclide then only that nuclide is updated. The evaluations are published in the journal Nuclear Data Sheets, Academicmore » Press, a division of Elsevier.« less
NASA Astrophysics Data System (ADS)
Rizzo, Axel; Vaglio-Gaudard, Claire; Martin, Julie-Fiona; Noguère, Gilles; Eschbach, Romain
2017-09-01
DARWIN2.3 is the reference package used for fuel cycle applications in France. It solves the Boltzmann and Bateman equations in a coupling way, with the European JEFF-3.1.1 nuclear data library, to compute the fuel cycle values of interest. It includes both deterministic transport codes APOLLO2 (for light water reactors) and ERANOS2 (for fast reactors), and the DARWIN/PEPIN2 depletion code, each of them being developed by CEA/DEN with the support of its industrial partners. The DARWIN2.3 package has been experimentally validated for pressurized and boiling water reactors, as well as for sodium fast reactors; this experimental validation relies on the analysis of post-irradiation experiments (PIE). The DARWIN2.3 experimental validation work points out some isotopes for which the depleted concentration calculation can be improved. Some other nuclides have no available experimental validation, and their concentration calculation uncertainty is provided by the propagation of a priori nuclear data uncertainties. This paper describes the work plan of studies initiated this year to improve the accuracy of the DARWIN2.3 depleted material balance calculation concerning some nuclides of interest for the fuel cycle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, B.; Firestone, R B.; Chu, S Y.F.
As part of a committment to maintain nuclear structure data as current as possible in the Evaluated Nuclear Structure Data File (ENSDF) and the Table of Isotopes, the author have been updating the information on superdeformed and hyperdeformed nuclear bands. As of February, 1996, they have compiled data for 161 superdeformed bands and 47 fission isomers identified in 93 nuclides for this publication. This is an increase of 75 superdeformed bands and 20 new nuclides since the first edition in 1994. Partial data for superdeformed bands and fission isomers are shown in the band drawings. For each nuclide there ismore » a complete level table listing both normal (taken from the ENSDF file) and superdeformed band assignments; level energy, spin, parity, half-life, magnetic moments, decay branchings; and the energies, final levels, relative intensities, multipolarities, and mixing ratios for transitions deexciting each level. Mass excess, decay energies, and proton and neutron separation energies are also provided from the evaluation of Audi and Wapstra. For superdeformed and hyperdeformed bands they provide the following quantities: level energies; level half-lives; level spins; and gamma ray energies.« less
Forbush decreases geomagnetic and atmospheric effects cosmogenic nuclides
NASA Technical Reports Server (NTRS)
Flueckiger, E. O.
1986-01-01
An overview and synthesis is given of recent developments that have occurred in the areas of Forbush decreases, geomagnetic and atmospheric effects, and cosmogenic nuclides. Experimental evidence has been found for substantial differences in the effects of the various types of interplanetary perturbations on cosmic rays, and for a dependence of these effects on the three-dimensional configuration of the interplanetary medium. In order to fully understand and to be able to simulate the solar cosmic ray particle access to the polar regions of the earth we need accurate models of the magnetospheric magnetic field. These models must include all major magnetospheric current systems (in particular the field aligned currents), and they should represent magnetically quiet time periods as well as different levels of geomagnetic activity. In the evolution of magnetospheric magnetic field models, cosmic ray and magnetospheric physicists should work closely together since cosmic ray measurements are a powerful additional tool in the study of the perturbed magnetosphere. In the field of cosmogenic nuclides, finally, exciting new results and developments follow in rapid succession. Thanks to new techniques and new isotopes the analysis of cosmic ray history has entered into a new dimension.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, E.J.
1976-02-01
A computer program is described which calculates nuclide concentration histories, power or neutron flux histories, burnups, and fission-product birthrates for fueled experimental capsules subjected to neutron irradiations. Seventeen heavy nuclides in the chain from $sup 232$Th to $sup 242$Pu and a user- specified number of fission products are treated. A fourth-order Runge-Kutta calculational method solves the differential equations for nuclide concentrations as a function of time. For a particular problem, a user-specified number of fuel regions may be treated. A fuel region is described by volume, length, and specific irradiation history. A number of initial fuel compositions may be specifiedmore » for each fuel region. The irradiation history for each fuel region can be divided into time intervals, and a constant power density or a time-dependent neutron flux is specified for each time interval. Also, an independent cross- section set may be selected for each time interval in each irradiation history. The fission-product birthrates for the first composition of each fuel region are summed to give the total fission-product birthrates for the problem.« less
NASA Astrophysics Data System (ADS)
Kanisch, G.
2017-05-01
The concepts of ISO 11929 (2010) are applied to evaluation of radionuclide activities from more complex multi-nuclide gamma-ray spectra. From net peak areas estimated by peak fitting, activities and their standard uncertainties are calculated by weighted linear least-squares method with an additional step, where uncertainties of the design matrix elements are taken into account. A numerical treatment of the standard's uncertainty function, based on ISO 11929 Annex C.5, leads to a procedure for deriving decision threshold and detection limit values. The methods shown allow resolving interferences between radionuclide activities also in case of calculating detection limits where they can improve the latter by including more than one gamma line per radionuclide. The co"mmon single nuclide weighted mean is extended to an interference-corrected (generalized) weighted mean, which, combined with the least-squares method, allows faster detection limit calculations. In addition, a new grouped uncertainty budget was inferred, which for each radionuclide gives uncertainty budgets from seven main variables, such as net count rates, peak efficiencies, gamma emission intensities and others; grouping refers to summation over lists of peaks per radionuclide.
Naswa, Niraj; Sharma, Punit; Gupta, Santosh Kumar; Karunanithi, Sellam; Reddy, Rama Mohan; Patnecha, Manish; Lata, Sneh; Kumar, Rakesh; Malhotra, Arun; Bal, Chandrasekhar
2014-01-01
This study aimed to compare the diagnostic performance of Ga-DOTANOC PET/CT with F-FDG PET/CT in the patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs). Data of 51 patients with definite histological diagnosis of GEP-NET who underwent both Ga-DOTA-NOC PET-CT and F-FDG PET-CT within a span of 15 days were selected for this retrospective analysis. Sensitivity, specificity, and predictive values were calculated for Ga-DOTA-NOC PET-CT and F-FDG PET-CT, and results were compared both on patientwise and regionwise analysis. Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT on patientwise analysis (P < 0.0001). On regionwise analysis, Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT only for lymph node metastases (P < 0.003). Although Ga-DOTA-NOC PET-CT detected more liver and skeletal lesions compared with F-FDG PET-CT, the difference was not statistically significant. In addition, the results of combined imaging helped in selecting candidates who would undergo the appropriate mode of treatment, whether octreotide therapy or conventional chemotherapy Ga-DOTA-NOC PET-CT seems to be superior to F-FDG PET-CT for imaging GEP-NETs. However, their role seems to be complementary because combination of Ga-DOTA-NOC PET-CT and F-FDG PET-CT in such patients helps demonstrate the total disease burden and segregate them to proper therapeutic groups.
Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.
Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra
2017-04-01
Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.
NASA Astrophysics Data System (ADS)
Pierre, Cynthia; Torkelson, John
2009-03-01
A major challenge for the most effective recycling of poly(ethylene terephthalate) concerns the fact that initial melt processing of PET into a product leads to substantial degradation of molecular weight. Thus, recycled PET has insufficient melt viscosity for reuse in high-value applications such as melt-blowing of PET bottles. Academic and industrial research has tried to remedy this situation by synthesis and use of ``chain extenders'' that can lead to branched PET (with higher melt viscosity than the linear recycled PET) via condensation reactions with functional groups on the PET. Here we show that simple processing of PET via solid-state shear pulverization (SSSP) leads to enhanced PET melt viscosity without need for chemical additives. We hypothesize that this branching results from low levels of chain scission accompanying SSSP, leading to formation of polymeric radicals that participate in chain transfer and combination reactions with other PET chains and thereby to in situ branch formation. The pulverized PET exhibits vastly enhanced crystallization kinetics, eliminating the need to employ cold crystallization to achieve maximum PET crystallinity. Results of SSSP processing of PET will be compared to results obtained with poly(butylene terephthalate).
Quantitative myocardial blood flow imaging with integrated time-of-flight PET-MR.
Kero, Tanja; Nordström, Jonny; Harms, Hendrik J; Sörensen, Jens; Ahlström, Håkan; Lubberink, Mark
2017-12-01
The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mean age 59 years; range 46-74 years) with known or suspected coronary artery disease underwent 15 O-water PET scans at rest and during adenosine-induced hyperaemia on a GE Discovery ST PET-CT and a GE Signa PET-MR scanner. PET-MR images were reconstructed using settings recommended by the manufacturer, including time-of-flight (TOF). Data were analysed semi-automatically using Cardiac VUer software, resulting in both parametric myocardial blood flow (MBF) images and segment-based MBF values. Correlation and agreement between PET-CT-based and PET-MR-based MBF values for all three coronary artery territories were assessed using regression analysis and intra-class correlation coefficients (ICC). In addition to the cardiac PET-MR reconstruction protocol as recommended by the manufacturer, comparisons were made using a PET-CT resolution-matched reconstruction protocol both without and with TOF to assess the effect of time-of-flight and reconstruction parameters on quantitative MBF values. Stress MBF data from one patient was excluded due to movement during the PET-CT scanning. Mean MBF values at rest and stress were (0.92 ± 0.12) and (2.74 ± 1.37) mL/g/min for PET-CT and (0.90 ± 0.23) and (2.65 ± 1.15) mL/g/min for PET-MR (p = 0.33 and p = 0.74). ICC between PET-CT-based and PET-MR-based regional MBF was 0.98. Image quality was improved with PET-MR as compared to PET-CT. ICC between PET-MR-based regional MBF with and without TOF and using different filter and reconstruction settings was 1.00. PET-MR-based MBF values correlated well with PET-CT-based MBF values and the parametric PET-MR images were excellent. TOF and reconstruction settings had little impact on MBF values.
Oberlin, Brandon G; Dzemidzic, Mario; Tran, Stella M; Soeurt, Christina M; Albrecht, Daniel S; Yoder, Karmen K; Kareken, David A
2013-08-01
Striatal dopamine (DA) is increased by virtually all drugs of abuse, including alcohol. However, drug-associated cues are also known to provoke striatal DA transmission- a phenomenon linked to the motivated behaviors associated with addiction. To our knowledge, no one has tested if alcohol's classically conditioned flavor cues, in the absence of a significant pharmacologic effect, are capable of eliciting striatal DA release in humans. Employing positron emission tomography (PET), we hypothesized that beer's flavor alone can reduce the binding potential (BP) of [(11)C]raclopride (RAC; a reflection of striatal DA release) in the ventral striatum, relative to an appetitive flavor control. Forty-nine men, ranging from social to heavy drinking, mean age 25, with a varied family history of alcoholism underwent two [(11)C]RAC PET scans: one while tasting beer, and one while tasting Gatorade. Relative to the control flavor of Gatorade, beer flavor significantly increased self-reported desire to drink, and reduced [(11)C]RAC BP, indicating that the alcohol-associated flavor cues induced DA release. BP reductions were strongest in subjects with first-degree alcoholic relatives. These results demonstrate that alcohol-conditioned flavor cues can provoke ventral striatal DA release, absent significant pharmacologic effects, and that the response is strongest in subjects with a greater genetic risk for alcoholism. Striatal DA responses to salient alcohol cues may thus be an inherited risk factor for alcoholism.
NASA Astrophysics Data System (ADS)
García Juan, David; Delattre, Bénédicte M. A.; Trombella, Sara; Lynch, Sean; Becker, Matthias; Choi, Hon Fai; Ratib, Osman
2014-03-01
Musculoskeletal disorders (MSD) are becoming a big healthcare economical burden in developed countries with aging population. Classical methods like biopsy or EMG used in clinical practice for muscle assessment are invasive and not accurately sufficient for measurement of impairments of muscular performance. Non-invasive imaging techniques can nowadays provide effective alternatives for static and dynamic assessment of muscle function. In this paper we present work aimed toward the development of a generic data structure for handling n-dimensional metabolic and anatomical data acquired from hybrid PET/MR scanners. Special static and dynamic protocols were developed for assessment of physical and functional images of individual muscles of the lower limb. In an initial stage of the project a manual segmentation of selected muscles was performed on high-resolution 3D static images and subsequently interpolated to full dynamic set of contours from selected 2D dynamic images across different levels of the leg. This results in a full set of 4D data of lower limb muscles at rest and during exercise. These data can further be extended to a 5D data by adding metabolic data obtained from PET images. Our data structure and corresponding image processing extension allows for better evaluation of large volumes of multidimensional imaging data that are acquired and processed to generate dynamic models of the moving lower limb and its muscular function.
Eyeblink Conditioning in Healthy Adults: A Positron Emission Tomography Study
Andreasen, Nancy C.; Liu, Dawei; Freeman, John H.; Boles Ponto, Laura L.; O’Leary, Daniel S.
2013-01-01
Eyeblink conditioning is a paradigm commonly used to investigate the neural mechanisms underlying motor learning. It involves the paired presentation of a toneconditioning stimulus which precedes and co-terminates with an airpuff unconditioned stimulus. Following repeated paired presentations a conditioned eyeblink develops which precedes the airpuff. This type of learning has been intensively studied and the cerebellum is known to be essential in both humans and animals. The study presented here was designed to investigate the role of the cerebellum during eyeblink conditioning in humans using positron emission tomography (PET). The sample includes 20 subjects (10 male and 10 female) with an average age of 29.2 years. PET imaging was used to measure regional cerebral blood flow (rCBF) changes occurring during the first, second, and third blocks of conditioning. In addition, stimuli-specific rCBF to unpaired tones and airpuffs (“pseudoconditioning”) was used as a baseline level that was subtracted from each block. Conditioning was performed using three, 15-trial blocks of classical eyeblink conditioning with the last five trials in each block imaged. As expected, subjects quickly acquired conditioned responses. A comparison between the conditioning tasks and the baseline task revealed that during learning there was activation of the cerebellum and recruitment of several higher cortical regions. Specifically, large peaks were noted in cerebellar lobules IV/V, the frontal lobes, and cingulate gyri. PMID:22430943
Eyeblink conditioning in unmedicated schizophrenia patients: A positron emission tomography study
Parker, Krystal L.; Andreasen, Nancy C.; Liu, Dawei; Freeman, John H.; O’Leary, Daniel S.
2014-01-01
Previous studies suggest that patients with schizophrenia exhibit dysfunctions in a widely distributed circuit—the cortico-cerebellar-thalamic-cortical circuit, or CCTCC—and that this may explain the multiple cognitive deficits observed in the disorder. This study uses positron emission tomography (PET) with O15 H2O to measure regional cerebral blood flow (rCBF) in response to a classic test of cerebellar function, the associative learning that occurs during eyeblink conditioning, in a sample of 20 unmedicated schizophrenia patients and 20 closely matched healthy controls. The PET paradigm examined three phases of acquisition and extinction (early, middle and late). The patients displayed impaired behavioral performance during both acquisition and extinction. The imaging data indicate that, compared to the control subjects, the patients displayed decreases in rCBF in all three components of the CCTCC during both acquisition and extinction. Specifically, patients had less rCBF in the middle and medial frontal lobes, anterior cerebellar lobules I/V and VI, as well as the thalamus during acquisition and although similar areas were found in the frontal lobe, ipsilateral cerebellar lobule IX showed consistently less activity in patients during extinction. Thus this study provides additional support for the hypothesis that patients with schizophrenia have a cognitive dysmetria—an inability to smoothly coordinate many different types of mental activity—that affects even a very basic cognitive task that taps into associative learning. PMID:24090512
18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma
Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E.
2016-01-01
Objectives The aim of this study was to compare 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to 18F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Materials and Methods Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board–approved study. After a single 18F-FDG injection, patients consecutively underwent 18F-FDG PET⁄CT and 18F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on 18F-FDG PET/CT and 18F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Results Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for 18F-FDG PET/CT, 18F-FDG PET/MR, and 18F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. 18F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and 18F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between 18F-FDG PET/MR DWI and 18F-FDG PET/CT, 99.2% (κ, 0.96) between 18F-FDG PET/MR and 18F-FDG PET/CT, and 99.4% (κ, 0.97) between 18F-FDG PET/MR DWI and 18F-FDG PET/MR. There was a strong correlation between 18F-FDG PET/CT and 18F-FDG PET/MR for SUVmax (r = 0.83) and SUVmean (r = 0.81) but no significant correlation between ADCmin and SUVmax (18F-FDG PET/CT: r = 0.46, P = 0.65; 18F-FDG PET/MR: r = 0.64, P = 0.53) or between ADCmean and SUVmean (respectively, r = −0.14, P = 0.17 for the correlation with PET/CT and r = −0.14, P = 0.14 for the correlation with PET/MR). Conclusions 18F-FDG PET/MR and 18F-FDG PET/CT show a similar diagnostic performance in lymphoma patients. However, if DWI is included in the 18F-FDG PET/MR protocol, results surpass those of 18F-FDG PET/CT because of the higher sensitivity of DWI for mucosa-associated lymphoid tissue lymphomas. PMID:26784400
NASA Astrophysics Data System (ADS)
Yang, Zhao-Ping; Xin, Chun-Ling; Guo, Ya-Feng; Luo, Yi-Wei; He, Ya-Dong
2016-05-01
Improving the melt viscoelasticity of poly(ethylene terephthalate) (PET) is a well-known method to obtain foamable PET. The aim of this study is to prepare high melt strength PET and evaluate the influence of rheological properties of PET on the foaming behavior. For this purpose, pyromelliticdianhydride was used as the chain extender to modify a linear PET through melt reactive processing. The rheological properties of the unmodified and modified PETs were measured by a dynamic rheometer. Results showed that the modified PET had higher complex viscosity than the unmodified one. Furthermore, the batch foaming by using supercritical CO2 as a blowing agent was carried to evaluate the foamability of modified PETs. It was found that an enlarged foaming temperature window was obtained for modified PETs compared to unmodified PET. Moreover, the modified PETs foams exhibited higher expansion ratio, smaller cell size and higher cell density at high temperatures than the neat PET.
Do allergic families avoid keeping furry pets?
Bertelsen, R J; Carlsen, K C L; Granum, B; Carlsen, K-H; Håland, G; Devulapalli, C S; Munthe-Kaas, M C; Mowinckel, P; Løvik, M
2010-06-01
Studies addressing the relationship between pet keeping and development of asthma and allergies may be influenced by pet avoidance in families with a history of allergic disease. Following a cohort of 1019 children in Oslo till 10 years of age, we studied the association of pet keeping with socio-economic factors and allergic disease in the family. A family history of asthma and rhinoconjunctivitis was not significantly associated with pet ownership at birth or with pet removal by 10 years. Acquiring cats and dogs was less likely if the child had allergic rhinoconjunctivitis, whereas no association was seen with asthma (in any family member). Single parenthood increased the likelihood of acquiring a cat, smoking parents more often had cats or dogs, and having older siblings was associated with keeping dogs and other furry pets. Among 319 families reporting pet avoidance, 70% never had pets, 8% had given up pets, and 22% avoided a particular type of pet only. Twenty-four per cent of the parents failed to retrospectively report pet keeping during the child's first year of life. Overall, allergic rhinitis, but not asthma was associated with actual pet avoidance, whereas the strongest predictors for keeping pets were found to be socio-economic factors. Allergic disease in a child most often does not lead to the removal of the family's furry pet. Pet avoidance is associated with allergic symptoms, but not asthma. Socio-economic factors like parental education, single parenthood and smoking affects the families' decisions on pet keeping, including the type of pets the families will avoid or acquire. The large recall error demonstrated points to the need for prospective data regarding pet keeping.
Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A
2014-03-01
Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging exhibited a high correlation (R = 0.74 and 0.86, respectively; P < 0.0001). Size measurements showed an excellent correlation between (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT (R = 0.99; P < 0.0001). The lower and upper limits of agreement between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging using Bland-Altman analysis were -2.34 to 3.89 for SUV(mean), -7.42 to 4.40 for SUV(max), and -0.59 to 0.83 for the tumor size, respectively. (18)F-FDG PET/MR imaging using a dedicated pulmonary MR imaging protocol, compared with (18)F-FDG PET/CT, does not provide advantages in thoracic staging in NSCLC patients.
Hawkins, Roxanne D.; Williams, Joanne M.
2017-01-01
Attachment to pets has an important role in children’s social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life) and pets (such as humane treatment). This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood. PMID:28481256
Treglia, Giorgio; Muoio, Barbara; Giovanella, Luca; Salvatori, Massimo
2013-05-01
Positron emission tomography (PET) and PET/computed tomography (PET/CT) with different tracers have been increasingly used in patients with thyroid tumours. The aim of this article is to perform an overview based on literature data about the usefulness of PET imaging in this setting. The role of Fluorine-18-Fluorodeoxyglucose (FDG) PET and PET/CT in differentiated thyroid carcinoma (DTC) is well established, particularly in patients presenting with elevated serum thyroglobulin levels and negative radioiodine whole-body scan. Iodine-124 PET and PET/CT may serve a role in staging DTC and obtaining lesional dosimetry for a better and more rationale planning of treatment with Iodine-131. FDG-PET and PET/CT are useful in the post-thyroidectomy staging of high-risk patients with less differentiated histological subtypes. PET and PET/CT with different tracers seem to be useful methods in localizing the source of elevated calcitonin levels in patients with recurrent medullary thyroid carcinoma. Incorporation of FDG-PET or PET/CT into the initial workup of patients with indeterminate thyroid nodules at fine needle aspiration biopsy deserves further investigation. FDG-PET report should suggest further evaluation when focal thyroid incidentalomas are described because these findings are associated with a significant risk of cancer.
Hawkins, Roxanne D; Williams, Joanne M; Scottish Society For The Prevention Of Cruelty To Animals Scottish Spca
2017-05-06
Attachment to pets has an important role in children's social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life) and pets (such as humane treatment). This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood.
Etchebehere, Elba C.; Hobbs, Brian P.; R.Milton, Denái; Malawi, Osama; Patel, Shreyaskumar; Benjamin, Robert S.; Macapinlac, Homer A.
2016-01-01
Purpose Twelve years ago a meta-analysis evaluated the diagnostic performance of 18F-FDG PET in assessing musculoskeletal soft tissue lesions (MsSTL). Currently, PET/CT has substituted PET imaging however there has not been any published meta-analysis on the use of PET/CT or a comparison of PET/CT with PET in the diagnosis of MsSTL. Therefore, we conducted a meta-analysis to identify the current diagnostic performance of 18F-FDG PET/CT and determine if there is added value when compared to PET. Patients and Methods A systematic review of English articles using MEDLINE PubMed, the Cochrane Library and EMBASE were searched from 1996 to March 2015. Studies exploring the diagnostic accuracy of 18F-FDG PET/CT (or dedicated PET) compared to histopathology in patients with MsSTL undergoing investigation for malignancy were included. Results Our meta-analysis included 14 articles composed of 755 patients with 757 soft tissue lesions. There were 451 (60%) malignant tumors and 306 benign lesions. The 18F-FDG PET/CT (and dedicated PET) mean sensitivity, specificity, accuracy, positive and negative predictive values for diagnosing MsSTL was 0.96 (0.90, 1.00), 0.77 (0.67, 0.86), 0.88 (0.85, 0.91), 0.86 (0.78, 0.94) and 0.91 (0.83, 0.99), respectively. The posterior mean (95% HPD interval) for the AUC was 0.92 (0.88, 0.96). PET/CT had higher specificity, accuracy and positive predictive value when compared to a dedicated PET (0.85, 0.89 and 0.91 vs 0.71, 0.85 and 0.82, respectively). Conclusions 18F-FDG PET/CT and dedicated PET are both highly accurate in the diagnosis of MsSTL. PET/CT is more accurate, specific and has a higher positive predictive value than PET. PMID:26631240
Burggraaff, Coreline N; Cornelisse, Alexander C; Hoekstra, Otto S; Lugtenburg, Pieternella J; de Keizer, Bart; Arens, Anne I J; Celik, Filiz; Huijbregts, Julia E; De Vet, Henrica C W; Zijlstra, Josee M
2018-05-04
We aimed to assess the interobserver agreement of Interim PET (I-PET) and End-of-Treatment PET (EoT-PET) using the Deauville 5-point scale (DS) in first-line DLBCL patients. Methods: I-PET and EoT-PET scans of DLBCL patients were performed in the HOVON84 study (2007-2012), an international multicenter randomized controlled trial. Patients received R-CHOP14 and were randomized to receive rituximab intensification in the first 4 cycles or not. I-PET was made after 4 cycles (for observational purposes), and EoT-PET scan after 6 or 8 cycles. Two independent central reviewers retrospectively scored all scans according to the DS-system, blinded to clinical outcomes. Results were dichotomised as 'negative' (DS: 1-3) or 'positive' (DS: 4-5). Besides percentage overall agreement we calculated agreement for positive and negative scores, expressed as positive agreement (PA) and negative agreement (NA), respectively. Results: 465 I-PET and 457 EoT-PET scans were centrally reviewed; baseline 18 F-FDG PET(/CT) was available in 75-77%, and CT in the remaining cases. Percentage overall agreement for I-PET and EoT-PET were 87.7% and 91.7% ( P =0.049), with NA of 92.0% and 95.0% ( P =0.091), and PA of 73.7% and 76.3% ( P =0.656), respectively. Conclusion: Interobserver agreement using DS in DLBCL patients in I-PET and EoT-PET yields high overall and negative agreement. The lower positive agreement suggests that EoT-PET/CT treatment evaluation in daily practice and I-PET adapted trials may benefit from dual reads and central review, respectively. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Georgi, Thomas Walter; Kluge, Regine; Kurch, Lars; Chavdarova, Lidia; Hasenclever, Dirk; Stoevesandt, Dietrich; Pelz, Tanja; Landman-Parker, Judith; Wallace, Hamish; Karlen, Jonas; Fernandez-Teijeiro, Ana; Cepelova, Michaela; Fossa, Alexander; Balwierz, Walentyna; Attarbaschi, Andishe; Ammann, Roland A; Pears, Jane; Hraskova, Andrea; Uyttebroeck, Anne; Beishuizen, Auke; Dieckmann, Karin; Leblanc, Thierry; Daw, Stephen; Baumann, Julia; Körholz, Dieter; Sabri, Osama; Mauz-Körholz, Christine
2018-04-13
Purpose: This study focused on skeletal involvement in FDG-PET (PET) in Hodgkin lymphoma (HL). We aimed at a systematic evaluation of the different types of skeletal involvement and their PET response after two cycles of chemotherapy (PET-2), to answer the question whether the current PET response criterion for skeletal involvement is suitable. A secondary objective was to observe the influence of initial uptake intensity and metabolic tumor volume (MTV) of skeletal lesions on the PET-2 response. Methods: Initial PET scans (PET-0) of 1068 pediatric HL patients from the EuroNet-PHL-C1 (C1) trial were evaluated by central review for skeletal involvement. Three types of skeletal lesions were distinguished: skeletal lesions detected only in PET (PETonly), bone marrow (BM) lesions confirmed by MRI or BM biopsy and bone lesions. Uptake intensity (measured as qPET value) and MTV were calculated for each skeletal lesion. All PET-2 scans were assessed for residual tumor activity. The rates of complete metabolic response in PET-2 of skeletal and nodal involvement were compared. Results: 139/1068 (13%) C1 patients showed skeletal involvement (44/139 PETonly patients, 32/139 BM patients and 63/139 bone patients). 101/139 (73%) patients became PET-2 negative in the skeleton while lymph node involvement was PET-2 negative in 94/139 (68%) patients. Highest skeletal PET-2 negative rate was seen in 42/44 (95%) PETonly patients, followed by 22/32 (69%) BM patients and 37/63 (59%) bone patients. Skeletal lesions who became PET-2 negative showed lower median values for initial qPET (2.74) and MTV (2ml) than lesions who remained PET-2 positive (3.84; 7ml). Conclusion: In this study with pediatric HL patients, the complete response rate in PET-2 of skeletal and nodal involvement was similar. Bone flare seemed to be irrelevant. Overall, the current skeletal PET response criterion - comparison with the local skeletal background - is well suited. Initial uptake intensity and MTV of skeletal lesions were predictive for the PET-2 result. Higher values for both parameters were associated with a worse PET-2 response. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Validation of a 4D-PET Maximum Intensity Projection for Delineation of an Internal Target Volume
DOE Office of Scientific and Technical Information (OSTI.GOV)
Callahan, Jason, E-mail: jason.callahan@petermac.org; Kron, Tomas; Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne
2013-07-15
Purpose: The delineation of internal target volumes (ITVs) in radiation therapy of lung tumors is currently performed by use of either free-breathing (FB) {sup 18}F-fluorodeoxyglucose-positron emission tomography-computed tomography (FDG-PET/CT) or 4-dimensional (4D)-CT maximum intensity projection (MIP). In this report we validate the use of 4D-PET-MIP for the delineation of target volumes in both a phantom and in patients. Methods and Materials: A phantom with 3 hollow spheres was prepared surrounded by air then water. The spheres and water background were filled with a mixture of {sup 18}F and radiographic contrast medium. A 4D-PET/CT scan was performed of the phantom whilemore » moving in 4 different breathing patterns using a programmable motion device. Nine patients with an FDG-avid lung tumor who underwent FB and 4D-PET/CT and >5 mm of tumor motion were included for analysis. The 3 spheres and patient lesions were contoured by 2 contouring methods (40% of maximum and PET edge) on the FB-PET, FB-CT, 4D-PET, 4D-PET-MIP, and 4D-CT-MIP. The concordance between the different contoured volumes was calculated using a Dice coefficient (DC). The difference in lung tumor volumes between FB-PET and 4D-PET volumes was also measured. Results: The average DC in the phantom using 40% and PET edge, respectively, was lowest for FB-PET/CT (DCAir = 0.72/0.67, DCBackground 0.63/0.62) and highest for 4D-PET/CT-MIP (DCAir = 0.84/0.83, DCBackground = 0.78/0.73). The average DC in the 9 patients using 40% and PET edge, respectively, was also lowest for FB-PET/CT (DC = 0.45/0.44) and highest for 4D-PET/CT-MIP (DC = 0.72/0.73). In the 9 lesions, the target volumes of the FB-PET using 40% and PET edge, respectively, were on average 40% and 45% smaller than the 4D-PET-MIP. Conclusion: A 4D-PET-MIP produces volumes with the highest concordance with 4D-CT-MIP across multiple breathing patterns and lesion sizes in both a phantom and among patients. Freebreathing PET/CT consistently underestimates ITV when compared with 4D PET/CT for a lesion affected by respiration.« less
A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System.
Li, Hongdi; Wang, Chao; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio; Liu, Shitao; An, Shaohui; Wong, Wai-Hoi
2010-04-01
The goal of this work is to develop a novel, accurate, real-time digital baseline restorer using online statistical processing for a high count-rate digital system such as positron emission tomography (PET). In high count-rate nuclear instrumentation applications, analog signals are DC-coupled for better performance. However, the detectors, pre-amplifiers and other front-end electronics would cause a signal baseline drift in a DC-coupling system, which will degrade the performance of energy resolution and positioning accuracy. Event pileups normally exist in a high-count rate system and the baseline drift will create errors in the event pileup-correction. Hence, a baseline restorer (BLR) is required in a high count-rate system to remove the DC drift ahead of the pileup correction. Many methods have been reported for BLR from classic analog methods to digital filter solutions. However a single channel BLR with analog method can only work under 500 kcps count-rate, and normally an analog front-end application-specific integrated circuits (ASIC) is required for the application involved hundreds BLR such as a PET camera. We have developed a simple statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. In this method, we acquire additional samples, excluding the real gamma pulses, from the existing free-running ADC in the digital system, and perform online statistical processing to generate a baseline value. This baseline value will be subtracted from the digitized waveform to retrieve its original pulse with zero-baseline drift. This method can self-track the baseline without a micro-controller involved. The circuit consists of two digital counter/timers, one comparator, one register and one subtraction unit. Simulation shows a single channel works at 30 Mcps count-rate with pileup condition. 336 baseline restorer circuits have been implemented into 12 field-programmable-gate-arrays (FPGA) for our new fully digital PET system.
Al-Bayati, Mohammad; Grueneisen, Johannes; Lütje, Susanne; Sawicki, Lino M; Suntharalingam, Saravanabavaan; Tschirdewahn, Stephan; Forsting, Michael; Rübben, Herbert; Herrmann, Ken; Umutlu, Lale; Wetter, Axel
2018-01-01
To evaluate diagnostic accuracy of integrated 68Gallium labelled prostate-specific membrane antigen (68Ga-PSMA)-11 positron emission tomography (PET)/MRI in patients with primary prostate cancer (PCa) as compared to multi-parametric MRI. A total of 22 patients with recently diagnosed primary PCa underwent clinically indicated 68Ga-PSMA-11 PET/CT for initial staging followed by integrated 68Ga-PSMA-11 PET/MRI. Images of multi-parametric magnetic resonance imaging (mpMRI), PET and PET/MRI were evaluated separately by applying Prostate Imaging Reporting and Data System (PIRADSv2) for mpMRI and a 5-point Likert scale for PET and PET/MRI. Results were compared with pathology reports of biopsy or resection. Statistical analyses including receiver operating characteristics analysis were performed to compare the diagnostic performance of mpMRI, PET and PET/MRI. PET and integrated PET/MRI demonstrated a higher diagnostic accuracy than mpMRI (area under the curve: mpMRI: 0.679, PET and PET/MRI: 0.951). The proportion of equivocal results (PIRADS 3 and Likert 3) was considerably higher in mpMRI than in PET and PET/MRI. In a notable proportion of equivocal PIRADS results, PET led to a correct shift towards higher suspicion of malignancy and enabled correct lesion classification. Integrated 68Ga-PSMA-11 PET/MRI demonstrates higher diagnostic accuracy than mpMRI and is particularly valuable in tumours with equivocal results from PIRADS classification. © 2018 S. Karger AG, Basel.
Pet ownership and adolescent health: cross-sectional population study.
Mathers, Megan; Canterford, Louise; Olds, Tim; Waters, Elizabeth; Wake, Melissa
2010-12-01
To determine whether adolescent health and well-being are associated with having a pet in the household (any pet, or specifically dogs, cats or horses/ponies) or average daily time spent caring for/playing with pet(s). Design, setting and participants--Cross-sectional data from the third wave of the Health of Young Victorians Study (HOYVS), a school-based population study in Victoria, Australia. Predictors--Adolescent-reported pet ownership and average daily time spent caring for/playing with pet(s). Outcomes--Self-reported quality of life (KIDSCREEN); average 4-day daily physical activity level from a computerised diary; parent-proxy and self-reported physical and psychosocial health status (PedsQL); measured BMI status (not overweight, overweight, obese) and blood pressure. Statistical Analysis--Regression methods, adjusted for socio-demographic factors, and non-parametric methods. Household pet data were available for 928 adolescents (466 boys; mean age of 15.9 (SD 1.2) years). Most adolescents (88.7%) reported having a pet in their household. Of these, 75.1% reported no activity involving pets over the surveyed days. It appeared that neither owning a pet nor time spent caring for/playing with a pet was related, positively or negatively, to adolescent health or well-being. Despite high rates of pet ownership, adolescents had little interaction with pets. It appears that owning a pet and time spent caring for/playing with a pet was not clearly associated with adolescents' health or well-being. © 2010 The Authors. Journal of Paediatrics and Child Health © 2010 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Devitt, Catherine; Downes, Marie T.; More, Simon J.
2015-01-01
Background. Failure among pet owners to neuter their pets results in increased straying and overpopulation problems. Variations in neutering levels can be explained by cultural differences, differences in economic status in rural and urban locations, and owner perceptions about their pet. There are also differences between male and female pet owners. There is no research pertaining to Irish pet owner attitudes towards neutering their pets. This paper identified the perceptions of a sample of Irish cat and dog owners that influenced their decisions on pet neutering. Methods. This study was conducted using social science (qualitative) methods, including an interview-administered survey questionnaire and focus group discussions. Data was coded and managed using Nvivo 8 qualitative data analysis software. Results. Focus groups were conducted with 43 pet (cats and dogs) owners. Two major categories relating to the decision to neuter were identified: (1) enabling perceptions in the decision to neuter (subcategories were: controlling unwanted pet behaviour; positive perceptions regarding pet health and welfare outcomes; perceived owner responsibility; pet function; and the influence of veterinary advice), and (2) disabling perceptions in the decision to neuter (subcategories were: perceived financial cost of neutering; perceived adequacy of existing controls; and negative perceptions regarding pet health and welfare outcomes). Discussion. Pet owner sense of responsibility and control are two central issues to the decision to neuter their pets. Understanding how pet owners feel about topics such as pet neutering, can help improve initiatives aimed at emphasising the responsibility of population control of cats and dogs. PMID:26312187
9 CFR 2.6 - Annual license fees.
Code of Federal Regulations, 2014 CFR
2014-01-01
... research facilities, dealers, exhibitors, retail pet stores, and persons for use as pets, directly or... animals to research facilities, dealers, exhibitors, retail pet stores, and persons for use as pets..., dealers, exhibitors, retail pet stores, and persons for use as pets, during the preceding business year...
9 CFR 2.6 - Annual license fees.
Code of Federal Regulations, 2012 CFR
2012-01-01
... research facilities, dealers, exhibitors, retail pet stores, and persons for use as pets, directly or... animals to research facilities, dealers, exhibitors, retail pet stores, and persons for use as pets..., dealers, exhibitors, retail pet stores, and persons for use as pets, during the preceding business year...
9 CFR 2.6 - Annual license fees.
Code of Federal Regulations, 2013 CFR
2013-01-01
... research facilities, dealers, exhibitors, retail pet stores, and persons for use as pets, directly or... animals to research facilities, dealers, exhibitors, retail pet stores, and persons for use as pets..., dealers, exhibitors, retail pet stores, and persons for use as pets, during the preceding business year...
9 CFR 2.6 - Annual license fees.
Code of Federal Regulations, 2011 CFR
2011-01-01
... research facilities, dealers, exhibitors, retail pet stores, and persons for use as pets, directly or... animals to research facilities, dealers, exhibitors, retail pet stores, and persons for use as pets..., dealers, exhibitors, retail pet stores, and persons for use as pets, during the preceding business year...
Melt rheological properties of nucleated PET/MWCNT nanocomposites
NASA Astrophysics Data System (ADS)
Gaonkar, Amita; Murudkar, Vrishali; Deshpande, V. D.
2018-05-01
This work investigates the effect of precipitated Polyethylene Terephthalate (p-PET) and loading of Multiwalled carbon nanotubes (MWCNT) on morphology and rheology of Polyethylene Terephthalate (PET)/MWCNT nanocomposites. As received PET and Self-Nucleated PET (Nuc-PET) nanocomposites with different loadings of multi-walled carbon nanotubes (MWCNT) were prepared by melt mixing technique. Synthesized reorganized PET crystallizes rapidly from the melt and it is used in small quantities as a self-nucleating agent to make Nuc-PET. In the present study, Rheological properties of nanocomposites are obtained and results show with increase in MWCNT loading complex viscosity of nanocomposites increases. Nonterminal solid like rheological behavior of PET nanocomposites were observed at low frequencies, which indicates the formation of the network like structures of MWCNT in nanocomposites. Morphological and rheological properties of self-nucleated PET nanocomposites improved significantly may be due to self-nucleating agent p-PET. Morphological properties were studied by Scanning Electron Microscopy (SEM). SEM shows better dispersion of MWCNT in Nuc-PET nanocomposites.
TH-E-202-02: The Use of Hypoxia PET Imaging for Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Humm, J.
2016-06-15
PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy.more » The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.« less
TH-E-202-00: PET for Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy.more » The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.« less
TH-E-202-03: PET for Tumor Response Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, W.
PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy.more » The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.« less
Coercive control and abused women's decisions about their pets when seeking shelter.
Hardesty, Jennifer L; Khaw, Lyndal; Ridgway, Marcella D; Weber, Cheryl; Miles, Teresa
2013-09-01
The importance of pets in families, especially during major life stressors, is well documented. Research suggests links between pet ownership and intimate partner violence (IPV). This study explored abused women's decisions about pets when seeking help from a shelter. Interviews were conducted with 19 women who were pet owners. Using grounded theory methods, two patterns emerged surrounding abusers' treatment of pets, bonds to pets, women's decisions about pets upon seeking shelter, and future plans for pets. The presence of coercive control was central to these patterns. Women also discussed their experiences with and needs from shelter professionals and veterinarians with implications for practice.
Beuthien-Baumann, B
2018-05-01
Positron emission tomography (PET) is a procedure in nuclear medicine, which is applied predominantly in oncological diagnostics. In the form of modern hybrid machines, such as PET computed tomography (PET/CT) and PET magnetic resonance imaging (PET/MRI) it has found wide acceptance and availability. The PET procedure is more than just another imaging technique, but a functional method with the capability for quantification in addition to the distribution pattern of the radiopharmaceutical, the results of which are used for therapeutic decisions. A profound knowledge of the principles of PET including the correct indications, patient preparation, and possible artifacts is mandatory for the correct interpretation of PET results.
Beiderwellen, Karsten J; Poeppel, Thorsten D; Hartung-Knemeyer, Verena; Buchbender, Christian; Kuehl, Hilmar; Bockisch, Andreas; Lauenstein, Thomas C
2013-05-01
The aim of this pilot study was to demonstrate the potential of simultaneously acquired 68-Gallium-DOTA-D-Phe1-Tyr3-octreotide (68Ga-DOTATOC) positron emission tomography/magnetic resonance imaging (PET/MRI) in comparison with 68Ga-DOTATOC PET/computed tomography (PET/CT) in patients with known gastroenteropancreatic neuroendocrine tumors (NETs). Eight patients (4 women and 4 men; mean [SD] age, 54 [17] years; median, 55 years; range 25-74 years) with histopathologically confirmed NET and scheduled 68Ga-DOTATOC PET/CT were prospectively enrolled for an additional integrated PET/MRI scan. Positron emission tomography/computed tomography was performed using a triple-phase contrast-enhanced full-dose protocol. Positron emission tomography/magnetic resonance imaging encompassed a diagnostic, contrast-enhanced whole-body MRI protocol. Two readers separately analyzed the PET/CT and PET/MRI data sets including their subscans in random order regarding lesion localization, count, and characterization on a 4-point ordinal scale (0, not visible; 1, benign; 2, indeterminate; and 3, malignant). In addition, each lesion was rated in consensus on a binary scale (allowing for benign/malignant only). Clinical imaging, existing prior examinations, and histopathology (if available) served as the standard of reference. In PET-positive lesions, the standardized uptake value (SUV max) was measured in consensus. A descriptive, case-oriented data analysis was performed, including determination of frequencies and percentages in detection of malignant, benign, and indeterminate lesions in connection to their localization. In addition, percentages in detection by a singular modality (such as PET, CT, or MRI) were calculated. Interobserver variability was calculated (Cohen's κ). The SUVs in the lesions in PET/CT and PET/MRI were measured, and the correlation coefficient (Pearson, 2-tailed) was calculated. According to the reference standard, 5 of the 8 patients had malignant NET lesions at the time of the examination. A total of 4 patients were correctly identified by PET/CT, with the PET and CT component correctly identifying 3 patients each. All 5 patients positive for NET disease were correctly identified by PET/MRI, with the MRI subscan identifying all 5 patients and the PET subscan identifying 3 patients. All lesions considered as malignant in PET/CT were equally depicted in and considered using PET/MRI. One liver lesion rated as "indetermined" in PET/CT was identified as metastasis in PET/MRI because of a diffusion restriction in diffusion-weighted imaging. Of the 4 lung lesions characterized in PET/CT, only 1 was depicted in PET/MRI. Of the 3 lymph nodes depicted in PET/CT, only 1 was characterized in PET/MRI. Interobserver reliability was equally very good in PET/CT (κ = 0.916) and PET/MRI (κ = 1.0). The SUV max measured in PET/CT and in PET/MRI showed a strong correlation (Pearson correlation coefficient, 0.996). This pilot study demonstrates the potential of 68Ga-DOTATOC PET/MRI in patients with gastroenteropancreatic NET, with special advantages in the characterization of abdominal lesions yet certain weaknesses inherent to MRI, such as lung metastases and hypersclerotic bone lesions.
Allen, Karen; Blascovich, Jim; Mendes, Wendy B
2002-01-01
The purpose of this study was to examine the effects of the presence of friends, spouses, and pets on cardiovascular reactivity to psychological and physical stress. Cardiovascular reactivity was examined among 240 married couples, half of whom owned a pet. Mental arithmetic and cold pressor were performed in one of four randomly assigned social support conditions: alone, with pet or friend (friend present for non-pet owners), with spouse, with spouse and pet/friend. Relative to people without pets, people with pets had significantly lower heart rate and blood pressure levels during a resting baseline, significantly smaller increases (ie, reactivity) from baseline levels during the mental arithmetic and cold pressor, and faster recovery. Among pet owners, the lowest reactivity and quickest recovery was observed in the pet-present conditions. People perceive pets as important, supportive parts of their lives, and significant cardiovascular and behavioral benefits are associated with those perceptions.
Catalano, Onofrio Antonio; Daye, Dania; Signore, Alberto; Iannace, Carlo; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Filomena, Mazzeo; Mansi, Luigi; Soricelli, Andrea; Salvatore, Marco; Fuin, Niccolo; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert
2017-07-01
The aim of the present study was to evaluate the performance of whole-body diffusion-weighted imaging (WB-DWI), whole-body positron emission tomography with computed tomography (WB-PET/CT), and whole-body positron emission tomography with magnetic resonance imaging (WB-PET/MRI) in staging patients with untreated invasive ductal carcinoma of the breast. Fifty-one women with newly diagnosed invasive ductal carcinoma of the breast underwent WB-DWI, WB-PET/CT and WB-PET/MRI before treatment. A radiologist and a nuclear medicine physician reviewed in consensus the images from the three modalities and searched for occurrence, number and location of metastases. Final staging, according to each technique, was compared. Pathology and imaging follow-up were used as the reference. WB-DWI, WB-PET/CT and WB-PET/MRI correctly and concordantly staged 33/51 patients: stage IIA in 7 patients, stage IIB in 8 patients, stage IIIC in 4 patients and stage IV in 14 patients. WB-DWI, WB-PET/CT and WB-PET/MRI incorrectly and concordantly staged 1/51 patient as stage IV instead of IIIA. Discordant staging was reported in 17/51 patients. WB-PET/MRI resulted in improved staging when compared to WB-PET/CT (50 correctly staged on WB-PET/MRI vs. 38 correctly staged on WB-PET/CT; McNemar's test; p<0.01). Comparing the performance of WB-PET/MRI and WB-DWI (43 correct) did not reveal a statistically significant difference (McNemar test, p=0.14). WB-PET/MRI is more accurate in the initial staging of breast cancer than WB-DWI and WB-PET/CT, however, the discrepancies between WB-PET/MRI and WB-DWI were not statistically significant. When available, WB-PET/MRI should be considered for staging patient with invasive ductal breast carcinoma.
Fischer, B M; Aznar, M C; Hansen, A E; Vogelius, I R; Löfgren, J; Andersen, F L; Loft, A; Kjaer, A; Højgaard, L; Specht, L
2015-01-01
Objective: To investigate reproducibility of fluorine-18 fludeoxyglucose (18F-FDG) uptake on 18F-FDG positron emission tomography (PET)/CT and 18F-FDG PET/MR scans in patients with head and neck squamous cell carcinoma (HNSCC). Methods: 30 patients with HNSCC were included in this prospective study. The patients were scanned twice before radiotherapy treatment with both PET/CT and PET/MR. Patients were scanned on the same scanners, 3 days apart and according to the same protocol. Metabolic tumour activity was measured by the maximum and peak standardized uptake value (SUVmax and SUVpeak, respectively), and total lesion glycolysis from the metabolic tumour volume defined from ≥50% SUVmax. Bland–Altman analysis with limits of agreement, coefficient of variation (CV) from the two modalities were performed in order to test the reproducibility. Furthermore, CVs from SUVmax and SUVpeak were compared. The area under the curve from cumulative SUV–volume histograms were measured and tested for reproducibility of the distribution of 18F-FDG uptake. Results: 24 patients had two pre-treatment PET/CT scans and 21 patients had two pre-treatment PET/MR scans available for further analyses. Mean difference for SUVmax, peak and mean was approximately 4% for PET/CT and 3% for PET/MR, with 95% limits of agreement less than ±20%. CV was small (5–7%) for both modalities. There was no significant difference in CVs between PET/CT and PET/MR (p = 0.31). SUVmax was not more reproducible than SUVpeak (p = 0.09). Conclusion: 18F-FDG uptake in PET/CT and PET/MR is highly reproducible and we found no difference in reproducibility between PET/CT and PET/MR. Advances in knowledge: This is the first report to test reproducibility of PET/CT and PET/MR. PMID:25634069
Yamashita, Shozo; Yokoyama, Kunihiko; Onoguchi, Masahisa; Yamamoto, Haruki; Hiko, Shigeaki; Horita, Akihiro; Nakajima, Kenichi
2014-01-01
Deep-inspiration breath-hold (DIBH) PET/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used.
Uprimny, Christian; Svirydenka, Anna; Fritz, Josef; Kroiss, Alexander Stephan; Nilica, Bernhard; Decristoforo, Clemens; Haubner, Roland; von Guggenberg, Elisabeth; Buxbaum, Sabine; Horninger, Wolfgang; Virgolini, Irene Johanna
2018-05-16
The purpose of this study was to investigate the diagnostic performance of 68 Ga-PSMA-11 PET/CT in the evaluation of bone metastases in metastatic prostate cancer (PC) patients scheduled for radionuclide therapy in comparison to [ 18 F]sodium fluoride ( 18 F-NaF) PET/CT. Sixteen metastatic PC patients with known skeletal metastases, who underwent both 68 Ga-PSMA-11 PET/CT and 18 F-NaF PET/CT for assessment of metastatic burden prior to radionuclide therapy, were analysed retrospectively. The performance of both tracers was calculated on a lesion-based comparison. Intensity of tracer accumulation of pathologic bone lesions on 18 F-NaF PET and 68 Ga-PSMA-11 PET was measured with maximum standardized uptake values (SUV max ) and compared to background activity of normal bone. In addition, SUV max values of PET-positive bone lesions were analysed with respect to morphologic characteristics on CT. Bone metastases were either confirmed by CT or follow-up PET scan. In contrast to 468 PET-positive lesions suggestive of bone metastases on 18 F-NaF PET, only 351 of the lesions were also judged positive on 68 Ga-PSMA-11 PET (75.0%). Intensity of tracer accumulation of pathologic skeletal lesions was significantly higher on 18 F-NaF PET compared to 68 Ga-PSMA-11 PET, showing a median SUV max of 27.0 and 6.0, respectively (p < 0.001). Background activity of normal bone was lower on 68 Ga-PSMA-11 PET, with a median SUV max of 1.0 in comparison to 2.7 on 18 F-NaF PET; however, tumour to background ratio was significantly higher on 18 F-NaF PET (9.8 versus 5.9 on 68 Ga-PSMA-11 PET; p = 0.042). Based on morphologic lesion characterisation on CT, 18 F-NaF PET revealed median SUV max values of 23.6 for osteosclerotic, 35.0 for osteolytic, and 19.0 for lesions not visible on CT, whereas on 68 Ga-PSMA-11 PET median SUV max values of 5.0 in osteosclerotic, 29.5 in osteolytic, and 7.5 in lesions not seen on CT were measured. Intensity of tracer accumulation between 18 F-NaF PET and 68 Ga-PSMA-11 PET was significantly higher in osteosclerotic (p < 0.001) and lesions not visible on CT (p = 0.012). In comparison to 68 Ga-PSMA-11 PET/CT, 18 F-NaF PET/CT detects a higher number of pathologic bone lesions in advanced stage PC patients scheduled for radionuclide therapy. Our data suggest that 68 Ga-PSMA-11 PET should be combined with 18 F-NaF PET in PC patients with skeletal metastases for restaging prior to initiation or modification of therapy.
Talking with Children about Furry Classroom Pets.
ERIC Educational Resources Information Center
Texas Child Care, 1994
1994-01-01
Notes that rodents and rabbits share many characteristics that make them suitable classroom pets and gives background information on rabbits, guinea pigs, hamsters, and gerbils. Offers advice on buying a classroom pet, the pet's home, feeding, helping the children handle the pet, and pet health and family planning. (TJQ)
Advances in prostate-specific membrane antigen PET of prostate cancer.
Bouchelouche, Kirsten; Choyke, Peter L
2018-05-01
In recent years, a large number of reports have been published on prostate-specific membrane antigen (PSMA)/PET in prostate cancer (PCa). This review highlights advances in PSMA PET in PCa during the past year. PSMA PET/computed tomography (CT) is useful in detection of biochemical recurrence, especially at low prostate-specific antigen (PSA) values. The detection rate of PSMA PET is influenced by PSA level. For primary PCa, PSMA PET/CT shows promise for tumour localization in the prostate, especially in combination with multiparametric MRI (mpMRI). For primary staging, PSMA PET/CT can be used in intermediate and high-risk PCa. Intraoperative PSMA radioligand guidance seems promising for detection of malignant lymph nodes. While the use of PSMA PET/MRI in primary localized disease is limited to high and intermediate-risk patients and localized staging, in the recurrence setting, PET/MRI can be particularly helpful when the lesions are subtle. PSMA PET/CT is superior to choline PET/CT and other conventional imaging modalities. Molecular imaging with PSMA PET continues to pave the way for personalized medicine in PCa.However, large prospective clinical studies are still needed to fully evaluate the role of PSMA PET/CT and PET/MRI in the clinical workflow of PCa.
NEMA NU 4-2008 comparison of preclinical PET imaging systems.
Goertzen, Andrew L; Bao, Qinan; Bergeron, Mélanie; Blankemeyer, Eric; Blinder, Stephan; Cañadas, Mario; Chatziioannou, Arion F; Dinelle, Katherine; Elhami, Esmat; Jans, Hans-Sonke; Lage, Eduardo; Lecomte, Roger; Sossi, Vesna; Surti, Suleman; Tai, Yuan-Chuan; Vaquero, Juan José; Vicente, Esther; Williams, Darin A; Laforest, Richard
2012-08-01
The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: microPET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand.
Abe, Katsumi; Kosuda, Shigeru; Kusano, Shoichi; Nagata, Masayoshi
2003-11-01
It is crucial to evaluate an annual balance before-hand when an institution installs a PET system because the revised Japanese national insurance reimbursement system set the cost of a FDG PET study as 75,000 yen. A break-even point was calculated in an 8-hour or a 24-hour operation of a PET system, based on the total costs reported. The break-even points were as follows: 13.4, 17.7, 22.1 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in an ordinary PET system operation of 8 hours. The break-even points were 19.9, 25.5, 31.2 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in a full PET system operation of 24 hours. The results indicate no profit would accrue in an ordinary PET system operation of 8 hours. The annual profit and break-even point for the total cost including the initial investment would be respectively 530 million yen and 2.8 years in a 24-hour operation with 1 cyclotron-3 PET cameras system.
Feasibility of FDG-PET in myocarditis: Comparison to CMR using integrated PET/MRI.
Nensa, Felix; Kloth, Julia; Tezgah, Ercan; Poeppel, Thorsten D; Heusch, Philipp; Goebel, Juliane; Nassenstein, Kai; Schlosser, Thomas
2018-06-01
Besides cardiac sarcoidosis, FDG-PET is rarely used in the diagnosis of myocardial inflammation, while cardiac MRI (CMR) is the actual imaging reference for the workup of myocarditis. Using integrated PET/MRI in patients with suspected myocarditis, we prospectively compared FDG-PET to CMR and the feasibility of integrated FDG-PET/MRI in myocarditis. A total of 65 consecutive patients with suspected myocarditis were prospectively assessed using integrated cardiac FDG-PET/MRI. Studies comprised T2-weighted imaging, late gadolinium enhancement (LGE), and simultaneous PET acquisition. Physiological glucose uptake in the myocardium was suppressed using dietary preparation. FDG-PET/MRI was successful in 55 of 65 enrolled patients: two patients were excluded due to claustrophobia and eight patients due to failed inhibition of myocardial glucose uptake. Compared with CMR (LGE and/or T2), sensitivity and specificity of PET was 74% and 97%. Overall spatial agreement between PET and CMR was κ = 0.73. Spatial agreement between PET and T2 (κ = 0.75) was higher than agreement between PET and LGE (κ = 0.64) as well as between LGE and T2 (κ = 0.56). In patients with suspected myocarditis, FDG-PET is in good agreement with CMR findings.
Martini, Katharina; Meier, Andreas; Opitz, Isabelle; Weder, Walter; Veit-Haibach, Patrick; Stahel, Rolf A; Frauenfelder, Thomas
2016-04-01
To investigate the diagnostic accuracy of sequential co-registered PET+MR (PET+MR) for local staging of malignant pleural mesothelioma (MPM) compared to PET/CT. In a prospective clinical trial 34 consecutive patients (median age 66 years; range 40-79 years; 1 female, 33 male) with known MPM, who underwent PET/CT and PET+MR exams for either staging or re-staging/follow-up were evaluated. Imaging was conducted using a tri-modality PET/CT-MR set-up (Discovery PET/CT 690, 3T Discovery MR 750w, both GE Healthcare, Waukesha, WI, USA). In 26 cases histopathology served as standard of reference. Two independent readers evaluated images for T and N stage, confidence level (sure to unsure; 1-3) and subjective overall image quality (very good to non-diagnostic; 1-4). Inter-observer agreement of T and N stages (Cohen's kappa) and interclass correlation coefficient (ICC) between PET/CT vs. PET+MR was calculated. Inter observer agreement for evaluation of T and N Stage in PET/CT images was excellent (k=0.844 and k=0.824, respectively), whereas PET+MR imaging showed substantial agreement in T and N stage (k=0.729 and k=0.691, respectively). The ICC of PET/CT vs. PET+MR for evaluation of both, T and N Stage, was excellent (ICC=0.951 and ICC=0.93, respectively). Diagnostic confidence was scored significantly higher in PET+MR compared to PET/CT (mean score=1.66 and 1.93, respectively; p=0.004). Image quality was diagnostic for all image series. Comparing pT and pN stage vs cT and cN stage (n=26 cases), both imaging modalities showed excellent agreement for T stage (ICCPET+MR=0.888 vs. ICCPET/CT=0.853, respectively) and substantial to moderate agreement for N stage (ICCPET+MR=0.683 vs. ICC=0.595PET/CT, respectively). Our findings suggest that diagnostic accuracy of PET+MR is comparable to PET/CT for local staging of MPM, whereas radiologists felt significantly more confident staging PET+MR compared to PET/CT images (p=0003), using dedicated sequences. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
SU-G-IeP4-07: Feasibility of Low Dose 18FDG PET in Pediatric Oncology Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, J; Binzel, K; Hall, NC
Purpose: To evaluate and demonstrate the feasibility of low dose FDG PET in pediatric oncology patients using virtual dose reduction as well as true patients PET/CT scans. Methods: Wholebody 18F-FDG PET/CT of 39 clinical pediatric patients (0.16±0.06MBq/kg) were scanned on a Gemini TF 64 system at 75±5 min post FDG injection using 3min/bed. Based on the 180s/bed listmode PET data, subsets of total counts in 120s, 90s, 60s, 30s and 15s per bed position were extracted for PET reconstruction to simulate lower dose PET at 2/3th, 1/2th, 1/3th, 1/6th and 1/12th dose levels. PET/CT scans of Jaszczak PET phantom withmore » 6 hot hollow spheres varying with sizes and contrast ratios were performed (real PET versus simulated PET) to validate the methodology of virtual dose PET simulation. Region of interests (ROIs) were placed on lesions and normal anatomical tissues with quantitative and qualitative assessment performed. Significant lower FDG dose PET/CT of 5 research adolescents were scanned to validate the proposal and low dose PET feasibility. Results: Although all lesions are visible on the 1/12th dose PET, overall PET image quality appears to be influenced in a multi-factorial way. 30%–60% dose reduction from current standard of care FDG PET is recommended to maintain equivalent quality and PET quantification. An optimized BMI-based FDG administration is recommended (from 1.1±0.5 mCi for BMI < 18.5 to 4.8±1.5 mCi for BMI > 30). A linear lowest “Dose-BMI” relationship is given. SUVs from 1/12th to full dose PETs were identified as consistent (R2 = 1.08, 0.99, 1.01, 1.00 and 0.98). No significant variances of count density, SUV and SNR were found across certain dose ranges (p<0.01). Conclusion: Pediatric PET/CT can be performed using current time-of-flight systems at substantially lower PET doses (30–60%) than the standard of care PET/CT without compromising qualitative and quantitative image quality in clinical.« less
Zirnsak, Mariana; Bärwolf, Robert; Freesmeyer, Martin
2016-11-08
Respiratory motion during PET/CT acquisition generates artifacts in the form of breath-related blurring, which influences the lesion detectability and diagnostic accuracy. The goal of this study was to verify whether breath-hold [68Ga]DOTA-TOC PET/CT (bhPET) allows detection of additional foci compared to free-breathing PET/CT (fbPET), and to assess the impact of breath-holding on standard uptake values (SUV) and isocontoured volume (Vic40) in patients with neuroendocrine tumors (NET). Patients with NET (n=39) were included in this study. BhPET and fbPET characteristics of 96 lesions were compared, and correlated with standard contrast-enhanced (ce) CT and MRI for lesion verification. Quantitative parameters SUV (max and mean) and Vic40 were assessed for both methods and evaluated by linear regression and Spearman's correlation. The impact of lesion size, localization and time interval between investigations was also analyzed. bhPET identified one additional metastasis not seen at fbPET but visible at ceMRI. Another additional bhPET focus did not have a morphological correlate. At bhPET, the SUVmax and SUVmean proved significantly higher and the Vic40 significantly lower than at fbPET. Lesion size, localization and time intervals did not impact significantly on SUV or Vic40. Currently, routine use of breath-hold [68Ga]DOTA-TOC PET/CT cannot be recommended as only one additional lesion was identified. Therefore, bhPET has currently no indication in patients with NET. If technical improvements regarding PET/CT scanner sensitivity are available, bhPET should be reevaluated in the future.
Ripa, Rasmus S; Knudsen, Andreas; Hag, Anne Mette F; Lebech, Anne-Mette; Loft, Annika; Keller, Sune H; Hansen, Adam E; von Benzon, Eric; Højgaard, Liselotte; Kjær, Andreas
2013-01-01
The study aimed at comparing PET/MR to PET/CT for imaging the carotid arteries in patients with known increased risk of atherosclerosis. Six HIV-positive men underwent sequential PET/MR and PET/CT of the carotid arteries after injection of 400 MBq of 18F-FDG. PET/MR was performed a median of 131 min after injection. Subsequently,PET/CT was performed. Regions of interest (ROI) were drawn slice by slice to include the carotid arteries and standardized uptake values (SUV) were calculated from both datasets independently. Quantitative comparison of 18F-FDG uptake revealed a high congruence between PET data acquired using the PET/MR system compared to the PET/CT system. The mean difference for SUVmean was -0.18 (p < 0.001) and -0.14 for SUVmax (p < 0.001) indicating a small but significant bias towards lower values using the PET/MR system. The 95% limits of agreement were -0.55 to 0.20 for SUVmean and -0.93 to 0.65 for SUVmax. The image quality of the PET/MR allowed for delineation of the carotid vessel wall. The correlations between 18F-FDG uptake from ROI including both vessel wall and vessel lumen to ROI including only the wall were strong (r = 0.98 for SUVmean and r = 1.00 for SUVmax) indicating that the luminal 18F-FDG content had minimal influence on the values. The study shows for the first time that simultaneous PET/MR of the carotid arteries is feasible in patients with increased risk of atherosclerosis. Quantification of 18F-FDG uptake correlated well between PET/MR and PET/CT despite difference in method of PET attenuation correction, reconstruction algorithm, and detector technology. PMID:23900769
Measurement of absolute gamma emission probabilities
NASA Astrophysics Data System (ADS)
Sumithrarachchi, Chandana S.; Rengan, Krish; Griffin, Henry C.
2003-06-01
The energies and emission probabilities (intensities) of gamma-rays emitted in radioactive decays of particular nuclides are the most important characteristics by which to quantify mixtures of radionuclides. Often, quantification is limited by uncertainties in measured intensities. A technique was developed to reduce these uncertainties. The method involves obtaining a pure sample of a nuclide using radiochemical techniques, and using appropriate fractions for beta and gamma measurements. The beta emission rates were measured using a liquid scintillation counter, and the gamma emission rates were measured with a high-purity germanium detector. Results were combined to obtain absolute gamma emission probabilities. All sources of uncertainties greater than 0.1% were examined. The method was tested with 38Cl and 88Rb.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaffke, Patrick John
This acts as a short note on the effects of varying the value of the endpoints of the thermal, epithermal, and fast flux groups. As expected, varying these endpoints can alter the value of the cross-section for a given nuclide. This effect is quantified in this note for an important nuclide in reactor simulations, 238U. Uranium-238 is responsible for the production of Plutonium in most reactors, making it critical to understand all of the 238U capture modes leading to Plutonium. We explicitly quantify the reaction rates for 238U that are altered when we use a given research reactor fluxmore » and vary the endpoint definitions of said flux as well as the reactor position.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayo, Douglas R.; Rawool-Sullivan, Mohini; Garner, Scott Edward
2016-06-01
238Pu is an ideal material for use as a heat source with its half-life of 87.7 years and copious particle emissions. 238Pu radioisotope thermoelectric generators (RTGs) have found use for pacemakers, Apollo Space missions, Mars rovers, and Voyager spacecraft. In evaluating the dose to personnel and components near a 238Pu-based RTG, a number of additional nuclides and their daughter products must be considered to get an accurate estimate for γ-dose, and the amount of 17O and 18O for the neutron-dose must be considered. This paper looks at the contributing nuclides and their daughter products that add the most to themore » dose rates.« less
Yang, Jaewon; Jian, Yiqiang; Jenkins, Nathaniel; Behr, Spencer C; Hope, Thomas A; Larson, Peder E Z; Vigneron, Daniel; Seo, Youngho
2017-07-01
Purpose To assess the patient-dependent accuracy of atlas-based attenuation correction (ATAC) for brain positron emission tomography (PET) in an integrated time-of-flight (TOF) PET/magnetic resonance (MR) imaging system. Materials and Methods Thirty recruited patients provided informed consent in this institutional review board-approved study. All patients underwent whole-body fluorodeoxyglucose PET/computed tomography (CT) followed by TOF PET/MR imaging. With use of TOF PET data, PET images were reconstructed with four different attenuation correction (AC) methods: PET with patient CT-based AC (CTAC), PET with ATAC (air and bone from an atlas), PET with ATAC patientBone (air and tissue from the atlas with patient bone), and PET with ATAC boneless (air and tissue from the atlas without bone). For quantitative evaluation, PET mean activity concentration values were measured in 14 1-mL volumes of interest (VOIs) distributed throughout the brain and statistical significance was tested with a paired t test. Results The mean overall difference (±standard deviation) of PET with ATAC compared with PET with CTAC was -0.69 kBq/mL ± 0.60 (-4.0% ± 3.2) (P < .001). The results were patient dependent (range, -9.3% to 0.57%) and VOI dependent (range, -5.9 to -2.2). In addition, when bone was not included for AC, the overall difference of PET with ATAC boneless (-9.4% ± 3.7) was significantly worse than that of PET with ATAC (-4.0% ± 3.2) (P < .001). Finally, when patient bone was used for AC instead of atlas bone, the overall difference of PET with ATAC patientBone (-1.5% ± 1.5) improved over that of PET with ATAC (-4.0% ± 3.2) (P < .001). Conclusion ATAC in PET/MR imaging achieves similar quantification accuracy to that from CTAC by means of atlas-based bone compensation. However, patient-specific anatomic differences from the atlas causes bone attenuation differences and misclassified sinuses, which result in patient-dependent performance variation of ATAC. © RSNA, 2017 Online supplemental material is available for this article.
Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.
Rakvongthai, Yothin; El Fakhri, Georges
2017-07-01
Motion degrades image quality and quantitation of PET images, and is an obstacle to quantitative PET imaging. Simultaneous PET-MR offers a tool that can be used for correcting the motion in PET images by using anatomic information from MR imaging acquired concurrently. Motion correction can be performed by transforming a set of reconstructed PET images into the same frame or by incorporating the transformation into the system model and reconstructing the motion-corrected image. Several phantom and patient studies have validated that MR-based motion correction strategies have great promise for quantitative PET imaging in simultaneous PET-MR. Copyright © 2017 Elsevier Inc. All rights reserved.
Sun, Yajuan; Yu, Hongjuan; Ma, Jingquan; Lu, Peiou
2016-01-01
The aim of our study was to evaluate the role of 18F-FDG PET/CT integrated imaging in differentiating malignant from benign pleural effusion. A total of 176 patients with pleural effusion who underwent 18F-FDG PET/CT examination to differentiate malignancy from benignancy were retrospectively researched. The images of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were visually analyzed. The suspected malignant effusion was characterized by the presence of nodular or irregular pleural thickening on CT imaging. Whereas on PET imaging, pleural 18F-FDG uptake higher than mediastinal activity was interpreted as malignant effusion. Images of 18F-FDG PET/CT integrated imaging were interpreted by combining the morphologic feature of pleura on CT imaging with the degree and form of pleural 18F-FDG uptake on PET imaging. One hundred and eight patients had malignant effusion, including 86 with pleural metastasis and 22 with pleural mesothelioma, whereas 68 patients had benign effusion. The sensitivities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging in detecting malignant effusion were 75.0%, 91.7% and 93.5%, respectively, which were 69.8%, 91.9% and 93.0% in distinguishing metastatic effusion. The sensitivity of 18F-FDG PET/CT integrated imaging in detecting malignant effusion was higher than that of CT imaging (p = 0.000). For metastatic effusion, 18F-FDG PET imaging had higher sensitivity (p = 0.000) and better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with CT imaging (Kappa = 0.917 and Kappa = 0.295, respectively). The specificities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were 94.1%, 63.2% and 92.6% in detecting benign effusion. The specificities of CT imaging and 18F-FDG PET/CT integrated imaging were higher than that of 18F-FDG PET imaging (p = 0.000 and p = 0.000, respectively), and CT imaging had better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with 18F-FDG PET imaging (Kappa = 0.881 and Kappa = 0.240, respectively). 18F-FDG PET/CT integrated imaging is a more reliable modality in distinguishing malignant from benign pleural effusion than 18F-FDG PET imaging and CT imaging alone. For image interpretation of 18F-FDG PET/CT integrated imaging, the PET and CT portions play a major diagnostic role in identifying metastatic effusion and benign effusion, respectively.
Freitag, Martin T; Radtke, Jan P; Afshar-Oromieh, Ali; Roethke, Matthias C; Hadaschik, Boris A; Gleave, Martin; Bonekamp, David; Kopka, Klaus; Eder, Matthias; Heusser, Thorsten; Kachelriess, Marc; Wieczorek, Kathrin; Sachpekidis, Christos; Flechsig, Paul; Giesel, Frederik; Hohenfellner, Markus; Haberkorn, Uwe; Schlemmer, Heinz-Peter; Dimitrakopoulou-Strauss, A
2017-05-01
The positron emission tomography (PET) tracer 68 Ga-PSMA-11, targeting the prostate-specific membrane antigen (PSMA), is rapidly excreted into the urinary tract. This leads to significant radioactivity in the bladder, which may limit the PET-detection of local recurrence (LR) of prostate cancer (PC) after radical prostatectomy (RP), developing in close proximity to the bladder. Here, we analyze if there is additional value of multi-parametric magnetic resonance imaging (mpMRI) compared to the 68 Ga-PSMA-11-PET-component of PET/CT or PET/MRI to detect LR. One hundred and nineteen patients with biochemical recurrence after prior RP underwent both hybrid 68 Ga-PSMA-11-PET/CT low-dose (1 h p.i.) and -PET/MRI (2-3 h p.i.) including a mpMRI protocol of the prostatic bed. The comparison of both methods was restricted to the abdomen with focus on LR (McNemar). Bladder-LR distance and recurrence size were measured in axial T2w-TSE. A logistic regression was performed to determine the influence of these variables on detectability in 68 Ga-PSMA-11-PET. Standardized-uptake-value (SUV mean ) quantification of LR was performed. There were 93/119 patients that had at least one pathologic finding. In addition, 18/119 Patients (15.1%) were diagnosed with a LR in mpMRI of PET/MRI but only nine were PET-positive in PET/CT and PET/MRI. This mismatch was statistically significant (p = 0.004). Detection of LR using the PET-component was significantly influenced by proximity to the bladder (p = 0.028). The PET-pattern of LR-uptake was classified into three types (1): separated from bladder; (2): fuses with bladder, and (3): obliterated by bladder). The size of LRs did not affect PET-detectability (p = 0.84), mean size was 1.7 ± 0.69 cm long axis, 1.2 ± 0.46 cm short-axis. SUV mean in nine men was 8.7 ± 3.7 (PET/CT) and 7.0 ± 4.2 (PET/MRI) but could not be quantified in the remaining nine cases (obliterated by bladder). The present study demonstrates additional value of hybrid 68 Ga-PSMA-11-PET/MRI by gaining complementary diagnostic information compared to the 68 Ga-PSMA-11-PET/CT low-dose for patients with LR of PC.
Li, Xiang; Heber, Daniel; Rausch, Ivo; Beitzke, Dietrich; Mayerhoefer, Marius E; Rasul, Sazan; Kreissl, Michael; Mitthauser, Markus; Wadsak, Wolfgang; Hartenbach, Markus; Haug, Alexander; Zhang, Xiaoli; Loewe, Christian; Beyer, Thomas; Hacker, Marcus
2016-07-01
PET with (18)F-FDG has the potential to assess vascular macrophage metabolism. (18)F-FDG is most often used in combination with contrast-enhanced CT to localize increased metabolism to specific arterial lesions. Novel (18)F-FDG PET/MRI hybrid imaging shows high potential for the combined evaluation of atherosclerotic plaques, due to the superior morphological conspicuity of plaque lesions. The purpose of this study was to evaluate the reliability and accuracy of (18)F-FDG PET/MRI uptake quantification compared to PET/CT as a reference standard in patients with carotid atherosclerotic plaques. The study group comprised 34 consecutive oncological patients with carotid plaques who underwent both PET/CT and PET/MRI with (18)F-FDG on the same day. The presence of atherosclerotic plaques was confirmed by 3 T MRI scans. Maximum standardized uptake values (SUVmax) for carotid plaque lesions and the average SUV of the blood pool within the adjacent internal jugular vein were determined and target-to-blood ratios (TBRs, plaque to blood pool) were calculated. Atherosclerotic lesions with maximum colocalized focal FDG uptake were assessed in each patient. SUVmax values of carotid plaque lesions were significantly lower on PET/MRI than on PET/CT (2.3 ± 0.6 vs. 3.1 ± 0.6; P < 0.01), but were significantly correlated between PET/CT and PET/MRI (Spearman's r = 0.67, P < 0.01). In contrast, TBRmax values of plaque lesions were similar on PET/MRI and on PET/CT (2.2 ± 0.3 vs. 2.2 ± 0.3; P = 0.4), and again were significantly correlated between PET/MRI and PET/CT (Spearman's r = 0.73, P < 0.01). Considering the increasing trend in SUVmax and TBRmax values from early to delayed imaging time-points on PET/CT and PET/MRI, respectively, with continuous clearance of radioactivity from the blood, a slight underestimation of TBRmax values may also be expected with PET/MRI compared with PET/CT. SUVmax and TBRmax values are widely accepted reference parameters for estimation of the radioactivity of atherosclerotic plaques on PET/CT. However, due to a systematic underestimation of SUVmax and TBRmax with PET/MRI, the optimal cut-off values indicating the presence of inflamed plaque tissue need to be newly defined for PET/MRI.
24 CFR 960.707 - Pet ownership.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false Pet ownership. 960.707 Section 960... ADMISSION TO, AND OCCUPANCY OF, PUBLIC HOUSING Pet Ownership in Public Housing § 960.707 Pet ownership. (a..., may own one or more common household pets or have one or more common household pets present in the...
24 CFR 960.707 - Pet ownership.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 4 2013-04-01 2013-04-01 false Pet ownership. 960.707 Section 960... ADMISSION TO, AND OCCUPANCY OF, PUBLIC HOUSING Pet Ownership in Public Housing § 960.707 Pet ownership. (a..., may own one or more common household pets or have one or more common household pets present in the...
24 CFR 960.707 - Pet ownership.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 4 2014-04-01 2014-04-01 false Pet ownership. 960.707 Section 960... ADMISSION TO, AND OCCUPANCY OF, PUBLIC HOUSING Pet Ownership in Public Housing § 960.707 Pet ownership. (a..., may own one or more common household pets or have one or more common household pets present in the...
24 CFR 960.707 - Pet ownership.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 4 2012-04-01 2012-04-01 false Pet ownership. 960.707 Section 960... ADMISSION TO, AND OCCUPANCY OF, PUBLIC HOUSING Pet Ownership in Public Housing § 960.707 Pet ownership. (a..., may own one or more common household pets or have one or more common household pets present in the...
Quartuccio, Natale; Treglia, Giorgio; Salsano, Marco; Mattoli, Maria Vittoria; Muoio, Barbara; Piccardo, Arnoldo; Lopci, Egesta; Cistaro, Angelina
2013-06-01
The objective of this study is to systematically review the role of positron emission tomography (PET) and PET/computed tomography (PET/CT) with Fluorine-18-Fluorodeoxyglucose (FDG) in patients with osteosarcoma (OS). A comprehensive literature search of published studies through October 10(th), 2012 in PubMed/MEDLINE, Embase and Scopus databases regarding whole-body FDG-PET and FDG-PET/CT in patients with OS was performed. We identified 13 studies including 289 patients with OS. With regard to the staging and restaging of OS, the diagnostic performance of FDG-PET and PET/CT seem to be high; FDG-PET and PET/CT seem to be superior to bone scintigraphy and conventional imaging methods in detecting bone metastases; conversely, spiral CT seems to be superior to FDG-PET in detecting pulmonary metastases from OS. Metabolic imaging may provide additional information in the evaluation of OS patients. The combination of FDG-PET or FDG-PET/CT with conventional imaging methods seems to be a valuable tool in the staging and restaging of OS and may have a relevant impact on the treatment planning.
Small Pilot Survey on Parents’ Perception of the Relationship between Children and Pets
Russo, Natalia; Vergnano, Diana; Bergero, Domenico
2017-01-01
Since companion animals are taking on more important roles in family life, the aim of this study was to evaluate the perception of parents about the relationship between their children and pets. A number of parents were asked to fill in a questionnaire; the principal topics were: pet ownership, pet care, relationship between pets and children, and sources of information about pet management. Eighty-two parents completed the survey; 71.4% of them already had pets before having children; pet care and health has emerged to be rather important, since 96.4% of the pets are taken to the veterinarian at least once a year; moreover, the great majority of the parents (97.2%) were not worried about the possible risks, linked to pets, pertaining to their child’s health. The present survey confirms that pets are mostly considered as members of the family, and not only as a benefit for the children. Moreover, the relationship between children and pets is basically seen as a positive experience for children. PMID:29056710
PET/CT versus body coil PET/MRI: how low can you go?
Appenzeller, P; Mader, C; Huellner, M W; Schmidt, D; Schmid, D; Boss, A; von Schulthess, G; Veit-Haibach, P
2013-08-01
The purpose of this study was to evaluate if positron emission tomography (PET)/magnetic resonance imaging (MRI) with just one gradient echo sequence using the body coil is diagnostically sufficient compared with a standard, low-dose non-contrast-enhanced PET/computed tomography (CT) concerning overall diagnostic accuracy, lesion detectability, size and conspicuity evaluation. Sixty-three patients (mean age 58 years, range 19-86 years; 23 women, 40 men) referred for either staging or restaging/follow-up of various malignant tumours (malignant melanoma, lung cancer, breast cancer, Hodgkin's lymphoma, non-Hodgkin's lymphoma, CUP, gynaecology tumours, pleural mesothelioma, oesophageal cancer, colorectal cancer, stomach cancer) were prospectively included. Imaging was conducted using a tri-modality PET/CT-MR set-up (full ring, time-of-flight Discovery PET/CT 690, 3 T Discovery MR 750, both GE Healthcare, Waukesha, WI). All patients were positioned on a dedicated PET/CT- and MR-compatible examination table, allowing for patient transport from the MR system to the PET/CT without patient movement. In accordance with RECIST 1.1 criteria, measurements of the maximum lesion diameters on CT and MR images were obtained. In lymph nodes, the short axis was measured. A four-point scale was used for assessment of lesion conspicuity: 1 (>25 % of lesion borders definable), 2 (25-50 %), 3 (50-75 %) and 4 (>75 %). For each lesion the corresponding anatomical structure was noted based on anatomical information of the spatially co-registered PET/CT and PET/MRI image sections. Additionally, lesions were divided into three categories: "tumour mass", "lymph nodes" and "lesions". Differences in overall lesion detectability and conspicuity in PET/CT and PET/MRI, as well as differences in detectability based on the localisation and lesion type, were analysed by Wilcoxon signed rank test. A total of 126 PET-positive lesions were evaluated. Overall, no statistically significant superiority of PET/CT over PET/MRI or vice versa in terms of lesion conspicuity was found (p = 0.095; mean score CT 2.93, mean score MRI 2.75). A statistically significant superiority concerning conspicuity of PET/CT over PET/MRI was found in pulmonary lesions (p = 0.016). Additionally, a statistically significant superiority of PET/CT over PET/MRI in "lymph nodes" regarding lesion conspicuity was also found (p = 0.033). A higher mean score concerning bone lesions were found for PET/CT compared with PET/MRI; however, these differences did not achieve statistical significance. Overall, PET/MRI with body coil acquisition does not match entirely the diagnostic accuracy of standard low-dose PET/CT. Thus, it might only serve as a back-up solution in very few patients. Overall, more time needs to be invested on the MR imaging part (higher matrix, more breath-holds, additional surface coil acquired sequences) to match up with the standard low-dose PET/CT. • Evaluation of whether PET/MRI with one sequence using body coil is diagnostically sufficient compared with PET/CT • PET/MRI with body coil does not match entirely the diagnostic accuracy of standard low-dose PET/CT • PET/MRI might only serve as a backup solution in patients.
Are Pets in the Bedroom a Problem?
Krahn, Lois E; Tovar, M Diane; Miller, Bernie
2015-12-01
The presence of pets in the bedroom can alter the sleep environment in ways that could affect sleep. Data were collected by questionnaire and interview from 150 consecutive patients seen at the Center for Sleep Medicine, Mayo Clinic in Arizona. Seventy-four people (49%) reported having pets, with 31 (41% of pet owners) having multiple pets. More than half of pet owners (56%) allowed their pets to sleep in the bedroom. Fifteen pet owners (20%) described their pets as disruptive, whereas 31 (41%) perceived their pets as unobtrusive or even beneficial to sleep. Health care professionals working with patients with sleep concerns should inquire about the presence of companion animals in the sleep environment to help them find solutions and optimize their sleep. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Basic study of entire whole-body PET scanners based on the OpenPET geometry
NASA Astrophysics Data System (ADS)
Yoshida, Eiji; Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo
2010-09-01
A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.
Freitag, Martin T; Kesch, Claudia; Cardinale, Jens; Flechsig, Paul; Floca, Ralf; Eiber, Matthias; Bonekamp, David; Radtke, Jan P; Kratochwil, Clemens; Kopka, Klaus; Hohenfellner, Markus; Stenzinger, Albrecht; Schlemmer, Heinz-Peter; Haberkorn, Uwe; Giesel, Frederik
2018-03-01
The aim of the present study was to explore the clinical feasibility and reproducibility of a comprehensive whole-body 18 F-PSMA-1007-PET/MRI protocol for imaging prostate cancer (PC) patients. Eight patients with high-risk biopsy-proven PC underwent a whole-body PET/MRI (3 h p.i.) including a multi-parametric prostate MRI after 18 F-PSMA-1007-PET/CT (1 h p.i.) which served as reference. Seven patients presented with non-treated PC, whereas one patient presented with biochemical recurrence. SUV mean -quantification was performed using a 3D-isocontour volume-of-interest. Imaging data was consulted for TNM-staging and compared with histopathology. PC was confirmed in 4/7 patients additionally by histopathology after surgery. PET-artifacts, co-registration of pelvic PET/MRI and MRI-data were assessed (PI-RADS 2.0). The examinations were well accepted by patients and comprised 1 h. SUV mean -values between PET/CT (1 h p.i.) and PET/MRI (3 h p.i.) were significantly correlated (p < 0.0001, respectively) and similar to literature of 18 F-PSMA-1007-PET/CT 1 h vs 3 h p.i. The dominant intraprostatic lesion could be detected in all seven patients in both PET and MRI. T2c, T3a, T3b and T4 features were detected complimentarily by PET and MRI in five patients. PET/MRI demonstrated moderate photopenic PET-artifacts surrounding liver and kidneys representing high-contrast areas, no PET-artifacts were observed for PET/CT. Simultaneous PET-readout during prostate MRI achieved optimal co-registration results. The presented 18 F-PSMA-1007-PET/MRI protocol combines efficient whole-body assessment with high-resolution co-registered PET/MRI of the prostatic fossa for comprehensive oncological staging of patients with PC.
Cheng, Nai-Ming; Fang, Yu-Hua Dean; Tsan, Din-Li
2016-01-01
Purpose We compared attenuation correction of PET images with helical CT (PET/HCT) and respiration-averaged CT (PET/ACT) in patients with non-small-cell lung cancer (NSCLC) with the goal of investigating the impact of respiration-averaged CT on 18F FDG PET texture parameters. Materials and Methods A total of 56 patients were enrolled. Tumors were segmented on pretreatment PET images using the adaptive threshold. Twelve different texture parameters were computed: standard uptake value (SUV) entropy, uniformity, entropy, dissimilarity, homogeneity, coarseness, busyness, contrast, complexity, grey-level nonuniformity, zone-size nonuniformity, and high grey-level large zone emphasis. Comparisons of PET/HCT and PET/ACT were performed using Wilcoxon signed-rank tests, intraclass correlation coefficients, and Bland-Altman analysis. Receiver operating characteristic (ROC) curves as well as univariate and multivariate Cox regression analyses were used to identify the parameters significantly associated with disease-specific survival (DSS). A fixed threshold at 45% of the maximum SUV (T45) was used for validation. Results SUV maximum and total lesion glycolysis (TLG) were significantly higher in PET/ACT. However, texture parameters obtained with PET/ACT and PET/HCT showed a high degree of agreement. The lowest levels of variation between the two modalities were observed for SUV entropy (9.7%) and entropy (9.8%). SUV entropy, entropy, and coarseness from both PET/ACT and PET/HCT were significantly associated with DSS. Validation analyses using T45 confirmed the usefulness of SUV entropy and entropy in both PET/HCT and PET/ACT for the prediction of DSS, but only coarseness from PET/ACT achieved the statistical significance threshold. Conclusions Our results indicate that 1) texture parameters from PET/ACT are clinically useful in the prediction of survival in NSCLC patients and 2) SUV entropy and entropy are robust to attenuation correction methods. PMID:26930211
Joint PET-MR respiratory motion models for clinical PET motion correction
NASA Astrophysics Data System (ADS)
Manber, Richard; Thielemans, Kris; Hutton, Brian F.; Wan, Simon; McClelland, Jamie; Barnes, Anna; Arridge, Simon; Ourselin, Sébastien; Atkinson, David
2016-09-01
Patient motion due to respiration can lead to artefacts and blurring in positron emission tomography (PET) images, in addition to quantification errors. The integration of PET with magnetic resonance (MR) imaging in PET-MR scanners provides complementary clinical information, and allows the use of high spatial resolution and high contrast MR images to monitor and correct motion-corrupted PET data. In this paper we build on previous work to form a methodology for respiratory motion correction of PET data, and show it can improve PET image quality whilst having minimal impact on clinical PET-MR protocols. We introduce a joint PET-MR motion model, using only 1 min per PET bed position of simultaneously acquired PET and MR data to provide a respiratory motion correspondence model that captures inter-cycle and intra-cycle breathing variations. In the model setup, 2D multi-slice MR provides the dynamic imaging component, and PET data, via low spatial resolution framing and principal component analysis, provides the model surrogate. We evaluate different motion models (1D and 2D linear, and 1D and 2D polynomial) by computing model-fit and model-prediction errors on dynamic MR images on a data set of 45 patients. Finally we apply the motion model methodology to 5 clinical PET-MR oncology patient datasets. Qualitative PET reconstruction improvements and artefact reduction are assessed with visual analysis, and quantitative improvements are calculated using standardised uptake value (SUVpeak and SUVmax) changes in avid lesions. We demonstrate the capability of a joint PET-MR motion model to predict respiratory motion by showing significantly improved image quality of PET data acquired before the motion model data. The method can be used to incorporate motion into the reconstruction of any length of PET acquisition, with only 1 min of extra scan time, and with no external hardware required.
Nagamachi, Shigeki; Nishii, Ryuichi; Wakamatsu, Hideyuki; Mizutani, Youichi; Kiyohara, Shogo; Fujita, Seigo; Futami, Shigemi; Sakae, Tatefumi; Furukoji, Eiji; Tamura, Shozo; Arita, Hideo; Chijiiwa, Kazuo; Kawai, Keiichi
2013-07-01
This study aimed at demonstrating the feasibility of retrospectively fused (18)F FDG-PET and MRI (PET/MRI fusion image) in diagnosing pancreatic tumor, in particular differentiating malignant tumor from benign lesions. In addition, we evaluated additional findings characterizing pancreatic lesions by FDG-PET/MRI fusion image. We analyzed retrospectively 119 patients: 96 cancers and 23 benign lesions. FDG-PET/MRI fusion images (PET/T1 WI or PET/T2WI) were made by dedicated software using 1.5 Tesla (T) MRI image and FDG-PET images. These images were interpreted by two well-trained radiologists without knowledge of clinical information and compared with FDG-PET/CT images. We compared the differential diagnostic capability between PET/CT and FDG-PET/MRI fusion image. In addition, we evaluated additional findings such as tumor structure and tumor invasion. FDG-PET/MRI fusion image significantly improved accuracy compared with that of PET/CT (96.6 vs. 86.6 %). As additional finding, dilatation of main pancreatic duct was noted in 65.9 % of solid types and in 22.6 % of cystic types, on PET/MRI-T2 fusion image. Similarly, encasement of adjacent vessels was noted in 43.1 % of solid types and in 6.5 % of cystic types. Particularly in cystic types, intra-tumor structures such as mural nodule (35.4 %) or intra-cystic septum (74.2 %) were detected additionally. Besides, PET/MRI-T2 fusion image could detect extra benign cystic lesions (9.1 % in solid type and 9.7 % in cystic type) that were not noted by PET/CT. In diagnosing pancreatic lesions, FDG-PET/MRI fusion image was useful in differentiating pancreatic cancer from benign lesions. Furthermore, it was helpful in evaluating relationship between lesions and surrounding tissues as well as in detecting extra benign cysts.
Cantiello, Francesco; Crocerossa, Fabio; Russo, Giorgio Ivan; Gangemi, Vincenzo; Ferro, Matteo; Vartolomei, Mihai Dorin; Lucarelli, Giuseppe; Mirabelli, Maria; Scafuro, Chiara; Ucciero, Giuseppe; De Cobelli, Ottavio; Morgia, Giuseppe; Damiano, Rocco; Cascini, Giuseppe Lucio
2018-06-04
To evaluate the diagnostic performance of 64 Cu-PSMA-617 positron emission tomography (PET) with computed tomography (CT) for restaging prostate cancer after biochemical recurrence (BCR) and to compare it with 18 F-choline PET/CT in a per-patient analysis. An observational study was performed of 43 patients with BCR after laparoscopic radical prostatectomy who underwent 64 Cu-PSMA-617 PET/CT and subsequently 18 F-choline PET/CT for restaging. The detection rates (DR) of 64 Cu-PSMA-617 PET/CT and of 18 F-choline PET/CT were calculated by standardized maximum uptake value (SUV max ) at 4 hours and SUV max at 1 hour as reference, respectively. Furthermore, univariate logistic regression analysis was carried out to identify independent predictive factors of positivity with 64 Cu-PSMA-617 PET/CT. An overall positivity with 64 Cu-PSMA-617 PET/CT was found in 32 patients (74.4%) versus 19 (44.2%) with 18 F-choline PET/CT. Specifically, after stratifying for prostate-specific antigen (PSA) values, we found a good performance of 64 Cu-PSMA-617 PET/CT at low PSA levels compared to 18 F-choline PET/CT, with a DR of 57.1% versus 14.3% for PSA 0.2-0.5 ng/mL (P = .031), and of 60% versus 30% with PSA 0.5-1 ng/mL. At univariate binary logistic regression analysis, PSA level was the only independent predictor of 64 Cu-PSMA-617 PET/CT positivity. No significant difference in terms of DR for both 64 Cu-PSMA-617 PET/CT and 18 F-choline PET/CT was found according to different Gleason score subgroups. In our study cohort, a better performance was observed for 64 Cu-PSMA-617 PET/CT compared to 18 F-choline PET/CT in restaging after BCR, especially in patients with low PSA values. Copyright © 2018 Elsevier Inc. All rights reserved.
TH-E-202-01: Pitfalls and Remedies in PET/CT Imaging for RT Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, T.
2016-06-15
PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy.more » The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.« less
2012-01-01
Background Many human infections are transmitted through contact with animals (zoonoses), including household pets. Although pet ownership is common in most countries and non-pet owners may have frequent contact with pets, there is limited knowledge of the public’s pet contact practices and awareness of zoonotic disease risks from pets. The objective of this study was to characterize the general public’s knowledge, attitudes and risks related to pet ownership and animal contact in southern Ontario, Canada. Methods A self-administered questionnaire was distributed to individuals at two multi-physician clinics in Waterloo, Ontario, Canada during 2010. A single adult from each household was invited to participate in the study. Results Seventy five percent (641/853) of individuals approached completed the questionnaire. Pet ownership and contact were common; 64% of participants had a pet in their household and 37% of non-pet owning households had a member with at least weekly animal contact outside the home. Pet ownership was high (55%) for households with individuals at higher risk for infections (i.e., < 5 yrs, ≥ 65 yrs, immunocompromised). Most respondents (64%) indicated that they had never received information regarding pet-associated disease risks. When given a list of 11 infectious pathogens, respondents were only able to correctly classify just over half on their potential to be transmitted from pets to people (mean 6.4); independently, pet owners and those who recalled receiving information in the past about this topic were able to make significantly more correct identifications. Pet (36%) and non-pet owning households (10%) reported dog or cat bites or scratches during the preceding year. Households with individuals at higher risk for an infection did not differ from the remaining households regarding their perceived disease risk of pets, zoonotic disease knowledge, recall of being asked by their medical provider if they owned any pets, or recall of having received information regarding pet-associated disease risks and preventive measures. Conclusions These results suggest that there is a need for accessible zoonotic disease information for both pet and non-owning households, with additional efforts made by veterinary, human and public health personnel. Immediate educational efforts directed toward households with individuals at higher risk to infections are especially needed. PMID:22831165
A novel preparation of milk protein/polyethylene terephthalate fabric
NASA Astrophysics Data System (ADS)
Zhou, J. F.; Zheng, D. D.; Zhong, L.; Zhang, F. X.; Zhang, G. X.
2016-07-01
In this work, -NH2 groups were introduced to polyethylene terephthalate (PET) fibers by nitration and reduction method, and then milk protein was grafted on the nitrated and reduced PET (NR PET) fibers by sucrose glycidyl ether crosslinking agent. FTIR suggested the milk protein was successfully grafted on PET fiber surface. SEM images showed a layer of substance covered on the PET fiber surface. DSC demonstrated an excellent thermal stability of milk protein/PET fiber. The moisture regain was improved by milk protein/PET fiber. Moreover, the crease recovery angle and stiffness were retained by the milk protein/PET fabric.
Gholamrezanezhad, Ali; Basques, Kyle; Batouli, Ali; Matcuk, George; Alavi, Abass; Jadvar, Hossein
2018-06-01
With improvements in PET/CT and PET/MRI over the last decade, as well as increased understanding of the pathophysiology of musculoskeletal diseases, there is an emerging potential for PET as a primary or complementary modality in the management of rheumatologic and orthopedic conditions. We discuss the role of PET/CT and PET/MRI in nononcologic musculoskeletal disorders, including inflammatory and infectious conditions and postoperative complications. There is great potential for an increased role for PET to serve as a primary or complementary modality in the management of orthopedic and rheumatologic disorders.
PET/MRI in cancer patients: first experiences and vision from Copenhagen.
Kjær, Andreas; Loft, Annika; Law, Ian; Berthelsen, Anne Kiil; Borgwardt, Lise; Löfgren, Johan; Johnbeck, Camilla Bardram; Hansen, Adam Espe; Keller, Sune; Holm, Søren; Højgaard, Liselotte
2013-02-01
Combined PET/MRI systems are now commercially available and are expected to change the medical imaging field by providing combined anato-metabolic image information. We believe this will be of particular relevance in imaging of cancer patients. At the Department of Clinical Physiology, Nuclear Medicine & PET at Rigshospitalet in Copenhagen we installed an integrated PET/MRI in December 2011. Here, we describe our first clinical PET/MR cases and discuss some of the areas within oncology where we envision promising future application of integrated PET/MR imaging in clinical routine. Cases described include brain tumors, pediatric oncology as well as lung, abdominal and pelvic cancer. In general the cases show that PET/MRI performs well in all these types of cancer when compared to PET/CT. However, future large-scale clinical studies are needed to establish when to use PET/MRI. We envision that PET/MRI in oncology will prove to become a valuable addition to PET/CT in diagnosing, tailoring and monitoring cancer therapy in selected patient populations.
Yoon, Hai-Jeon; Yoo, Jang; Kim, Yemi; Lee, Dong Hyeon; Kim, Bom Sahn
2017-10-01
We investigated the value of early dynamic (ED) PET for the detection and characterization of bladder cancer. Fifty-two bladder cancer patients were prospectively enrolled. The study protocol was composed of ED, whole-body (WB, 60 minutes after injection), and additional delayed (AD, 120 minutes after injection) PET acquisition. Early dynamic PET was acquired for 10 minutes and reconstructed as 5 frames at 2-minute intervals. A focal radiotracer accumulation confined to the bladder wall was considered as PET positive and referred for further quantitative measurement. SUVmax on ED (SUVmax, SUVmax, SUVmax, SUVmax, and SUVmax for 5 frames), WB (SUVmax), and AD PET (SUVmax) were measured. PET results were correlated with bladder cancer pathology variables. The sensitivities of ED, WB, and AD PET for bladder cancer were 84.6%, 57.7%, and 61.2%, respectively. The sensitivity of ED PET was significantly higher than that of WB (P = 0.002) and AD PET (P = 0.008). On ED PET, SUVmax was significantly correlated with muscle invasiveness, histological grade, and pathological tumor size (P = 0.018, P = 0.030, and P = 0.030). On WB and AD PET, only pathological tumor size showed significant positive correlation with SUVmax and SUVmax (P = 0.043 and P = 0.007). Early dynamic PET can help to detect and characterize bladder cancer.
Evacuating People and Their Pets: Older Floridians' Need for and Proximity to Pet-Friendly Shelters.
Douglas, Rachel; Kocatepe, Ayberk; Barrett, Anne E; Ozguven, Eren Erman; Gumber, Clayton
2017-10-04
Pets influence evacuation decisions, but little is known about pet-friendly emergency shelters' availability or older adults' need for them. Our study addresses this issue, focusing on the most densely populated area of Florida (Miami-Dade)-the state with the oldest population and greatest hurricane susceptibility. We use Geographic Information Systems (GIS)-based methodology to identify the shortest paths to pet-friendly shelters, based on distance and congested and uncongested travel times-taking into account the older population's spatial distribution. Logistic regression models using the 2013 American Housing Survey's Disaster Planning Module examine anticipated shelter use as a function of pet ownership and requiring pet evacuation assistance. Thirty-four percent of older adults in the Miami-Dade area have pets-35% of whom report needing pet evacuation assistance. However, GIS accessibility measures show that travel time factors are likely to impede older adults' use of the area's few pet-friendly shelters. Logistic regression results reveal that pet owners are less likely to report anticipating shelter use; however, the opposite holds for pet owners reporting they would need help evacuating their pets-they anticipate using shelters. High pet shelter need coupled with low availability exacerbates older adults' heightened vulnerability during Florida's hurricane season. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems
Goertzen, Andrew L.; Bao, Qinan; Bergeron, Mélanie; Blankemeyer, Eric; Blinder, Stephan; Cañadas, Mario; Chatziioannou, Arion F.; Dinelle, Katherine; Elhami, Esmat; Jans, Hans-Sonke; Lage, Eduardo; Lecomte, Roger; Sossi, Vesna; Surti, Suleman; Tai, Yuan-Chuan; Vaquero, Juan José; Vicente, Esther; Williams, Darin A.; Laforest, Richard
2014-01-01
The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. Methods We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: micro- PET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. Results The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. Conclusion Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand. PMID:22699999
Positron Emission Tomography - Computed Tomography (PET/CT)
... A-Z Positron Emission Tomography - Computed Tomography (PET/CT) Positron emission tomography (PET) uses small amounts of ... What is Positron Emission Tomography – Computed Tomography (PET/CT) Scanning? Positron emission tomography, also called PET imaging ...
Pet Ownership by Elderly People: Two New Issues.
ERIC Educational Resources Information Center
Smith, David W. E.; And Others
1992-01-01
Examined two issues of pet ownership in mail questionnaire and interview survey of 1,595 older adults over age 60, 377 of whom had a pet. Found evidence that pets were important determinant of housing choice. Many elderly pet owners had made no arrangements for pet if they predecease it or become unable to care for it. (Author/NB)
Parida, Girish Kumar; Tripathy, Sarthak; Datta Gupta, Shreya; Singhal, Abhinav; Kumar, Rakesh; Bal, Chandrasekhar; Shamim, Shamim Ahmed
2018-04-01
Ga-PSMA PET/CT is the upcoming imaging modality for staging, restaging and response assessment of prostate cancer. However, due to neuroendocrine differentiation in some of patients with prostate cancer, they express somatostatin receptors instead of prostate specific membrane antigen. This can be exploited and other modalities like Ga-DOTANOC PET/CT and F-FDG PET/CT should be used in such cases for guiding management. We hereby discuss a similar case of 67-year-old man of adenocarcinoma prostate with neuroendocrine differentiation, which shows the potential pitfall of Ga-PSMA PET/CT imaging and benefit of Ga-DOTANOC PET/CT and F-FDG PET/CT in such cases.
Coordination Chemistry of Disilylated Germylenes with Group 4 Metallocenes
2013-01-01
Reaction of the PEt3 adduct of a disilylated five-membered cyclic germylene with group 4 metallocene dichlorides in the presence of magnesium led to the formation of the respective germylene metallocene phosphine complexes of titanium, zirconium, and hafnium. Attempts to react the related NHC adduct of a disilylated four-membered cyclic germylene under the same conditions with Cp2TiCl2 did not give the expected germylene NHC titanocene complex. This complex was, however, obtained in the reaction of Cp2Ti(btmsa) with the NHC germylene adduct. A computational analysis of the structure of the group 4 metallocene germylene complexes revealed the multiple-bond character of the M–Ge(II) linkage, which can be rationalized with the classical σ-donor/π-acceptor interaction. The strength of the M–Ge(II) bond increases descending group 4. PMID:23874053
Salva, Inês; de Sousa, Rita; Gouveia, Catarina
2014-03-10
Rickettsial infections are common in southern Europe and the most frequent and lethal type is Mediterranean spotted fever, caused by Rickettsia conorii. The disease is usually characterised by the classical triad of fever, eschar and rash, and is generally a mild disease in children. Complications including neurological involvement are rarely described. We report an unusual case of meningitis in an 18-year-old man, presenting during summer with fever and persistent headache. The cerebrospinal fluid analysis revealed increased cellularity (107 cells/μL), hypoglycorrhachia (50% of glycaemia) and hyperproteinorrhachia (284 mg/dL). Rickettsial infection was confirmed by serology and the patient was treated with doxycycline, with a favourable outcome. The patient's pet squirrel and/or associated vectors might be involved in the transmission of Rickettsia spp. This case underlines the importance of a high clinical suspicion and the benefits of early empirical treatment when facing compatible epidemiological contexts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang Shan; Shen Hongtao; He Ming
2010-05-12
Accelerator Mass Spectrometry (AMS), initiated in late 1970s at McMaster university based on the accelerator and detector technique, has long been applied in the studies on archaeology, geology, and cosmology, as a powerful tool for isotope dating. The advantages of AMS in the analysis of rare nuclides by direct counting of the atoms, small sample size and relatively free from the interferences of molecular ions have been well documented. This paper emphasizes that AMS can not only be used for archaeology, geology, environment, biology and so on, but also served as a unique tool for nuclear physics research. In thismore » paper, the determination of the half-lives of {sup 79}Se, the measurements of the cross-sections of {sup 93}Nb(n,2n){sup 92g}Nb and {sup 238}U(n,3n){sup 236}U reactions, the detection and determination of ultratrace impurities in neutrino detector materials, and the measurement of the fission product nuclide {sup 126}Sn, are to be introduced, as some of examples of AMS applications in nuclear research conducted in AMS lab of China Institute of Atomic Energy. Searching for superheavy nuclides by using AMS is being planned.« less
ICoN, the Interactive Chart of Nuclides
NASA Astrophysics Data System (ADS)
Lee, Kevin; Mumpower, Matthew; Aprahamian, Ani
2015-10-01
Nuclear data is critical to research fields from medicine to astrophysics. The chart of nuclides is a more descriptive version of the periodic table that can be used to visualize nuclear properties such as half-lives and mass. We have created ICoN (simply short for Interactive Chart of Nuclides), an API which can be used to visualize theoretical and experimental datasets. This visualization is achieved by using D3 (Data Driven Documents), HTML, and CSS3 to plot the elements and color them accordingly. ICoN features many customization options that users can access that are dynamically applied to the chart without reloading the page. Users can save the customized chart they create to various formats. We have constructed these features in order to provide a unique approach for researchers to interface with nuclear data. ICoN can also be used on all electronic devices without loss of support. We report on the current progress of this project and will present a working demo that highlights each aspect of the aforementioned features. This is the first time that all available technologies are put to use to make nuclear data more accessible than ever before. This is a first and we will make it available as open source ware.
Ji, Young-Yong; Kim, Chang-Jong; Lim, Kyo-Sun; Lee, Wanno; Chang, Hyon-Sock; Chung, Kun Ho
2017-10-01
To expand the application of dose rate spectroscopy to the environment, the method using an environmental radiation monitor (ERM) based on a 3' × 3' NaI(Tl) detector was used to perform real-time monitoring of the dose rate and radioactivity for detected gamma nuclides in the ground around an ERM. Full-energy absorption peaks in the energy spectrum for dose rate were first identified to calculate the individual dose rates of Bi, Ac, Tl, and K distributed in the ground through interference correction because of the finite energy resolution of the NaI(Tl) detector used in an ERM. The radioactivity of the four natural radionuclides was then calculated from the in situ calibration factor-that is, the dose rate per unit curie-of the used ERM for the geometry of the ground in infinite half-space, which was theoretically estimated by Monte Carlo simulation. By an intercomparison using a portable HPGe and samples taken from the ground around an ERM, this method to calculate the dose rate and radioactivity of four nuclides using an ERM was experimentally verified and finally applied to remotely monitor them in real-time in the area in which the ERM had been installed.
Uncertainties in s -process nucleosynthesis in low mass stars determined from Monte Carlo variations
NASA Astrophysics Data System (ADS)
Cescutti, G.; Hirschi, R.; Nishimura, N.; den Hartogh, J. W.; Rauscher, T.; Murphy, A. St J.; Cristallo, S.
2018-05-01
The main s-process taking place in low mass stars produces about half of the elements heavier than iron. It is therefore very important to determine the importance and impact of nuclear physics uncertainties on this process. We have performed extensive nuclear reaction network calculations using individual and temperature-dependent uncertainties for reactions involving elements heavier than iron, within a Monte Carlo framework. Using this technique, we determined the uncertainty in the main s-process abundance predictions due to nuclear uncertainties link to weak interactions and neutron captures on elements heavier than iron. We also identified the key nuclear reactions dominating these uncertainties. We found that β-decay rate uncertainties affect only a few nuclides near s-process branchings, whereas most of the uncertainty in the final abundances is caused by uncertainties in neutron capture rates, either directly producing or destroying the nuclide of interest. Combined total nuclear uncertainties due to reactions on heavy elements are in general small (less than 50%). Three key reactions, nevertheless, stand out because they significantly affect the uncertainties of a large number of nuclides. These are 56Fe(n,γ), 64Ni(n,γ), and 138Ba(n,γ). We discuss the prospect of reducing uncertainties in the key reactions identified in this study with future experiments.
Nuclear decay data files of the Dosimetry Research Group
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckerman, K.F.; Westfall, R.J.; Ryman, J.C.
1993-12-01
This report documents the nuclear decay data files used by the Dosimetry Research Group at Oak Ridge National Laboratory and the utility DEXRAX which provides access to the files. The files are accessed, by nuclide, to extract information on the intensities and energies of the radiations associated with spontaneous nuclear transformation of the radionuclides. In addition, beta spectral data are available for all beta-emitting nuclides. Two collections of nuclear decay data are discussed. The larger collection contains data for 838 radionuclides, which includes the 825 radionuclides assembled during the preparation of Publications 30 and 38 of the International Commission onmore » Radiological Protection (ICRP) and 13 additional nuclides evaluated in preparing a monograph for the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. The second collection is composed of data from the MIRD monograph and contains information for 242 radionuclides. Abridged tabulations of these data have been published by the ICRP in Publication 38 and by the Society of Nuclear Medicine in a monograph entitled ``MIRD: Radionuclide Data and Decay Schemes.`` The beta spectral data reported here have not been published by either organization. Electronic copies of the files and the utility, along with this report, are available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.« less
Prediction of standard-dose brain PET image by using MRI and low-dose brain [18F]FDG PET images.
Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S; Lin, Weili; Shen, Dinggang
2015-09-01
Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient's exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [(18)F]FDG PET image by using a low-dose brain [(18)F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. The authors employ a regression forest for predicting the standard-dose brain [(18)F]FDG PET image by low-dose brain [(18)F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [(18)F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [(18)F]FDG PET image and substantially enhanced image quality of low-dose brain [(18)F]FDG PET image. In this paper, the authors propose a framework to generate standard-dose brain [(18)F]FDG PET image using low-dose brain [(18)F]FDG PET and MRI images. Both the visual and quantitative results indicate that the standard-dose brain [(18)F]FDG PET can be well-predicted using MRI and low-dose brain [(18)F]FDG PET.
Prediction of standard-dose brain PET image by using MRI and low-dose brain [18F]FDG PET images
Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S.; Lin, Weili; Shen, Dinggang
2015-01-01
Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [18F]FDG PET image by using a low-dose brain [18F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [18F]FDG PET image by low-dose brain [18F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [18F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [18F]FDG PET image and substantially enhanced image quality of low-dose brain [18F]FDG PET image. Conclusions: In this paper, the authors propose a framework to generate standard-dose brain [18F]FDG PET image using low-dose brain [18F]FDG PET and MRI images. Both the visual and quantitative results indicate that the standard-dose brain [18F]FDG PET can be well-predicted using MRI and low-dose brain [18F]FDG PET. PMID:26328979
Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain.
Jung, Jin Ho; Choi, Yong; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun; Oh, Chang Hyun; Park, Hyun-wook; Kim, Kyung Min; Kim, Jong Guk
2015-05-01
The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was maintained. The change of gain of the 256 GAPD/scintillator elements of a detector block was <3% for 60 min, and simultaneous PET and MR images of a brain phantom were successfully acquired. Experimental results indicate that a compact and lightweight PET insert for hybrid PET/MRI can be developed using GAPD arrays and charge signal transmission method proposed in this study without significant interference.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, Jiayin; Gao, Yaozong; Shi, Feng
Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. Asmore » yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [{sup 18}F]FDG PET image by using a low-dose brain [{sup 18}F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [{sup 18}F]FDG PET image by low-dose brain [{sup 18}F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [{sup 18}F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [{sup 18}F]FDG PET image and substantially enhanced image quality of low-dose brain [{sup 18}F]FDG PET image. Conclusions: In this paper, the authors propose a framework to generate standard-dose brain [{sup 18}F]FDG PET image using low-dose brain [{sup 18}F]FDG PET and MRI images. Both the visual and quantitative results indicate that the standard-dose brain [{sup 18}F]FDG PET can be well-predicted using MRI and low-dose brain [{sup 18}F]FDG PET.« less
Gatidis, Sergios; Würslin, Christian; Seith, Ferdinand; Schäfer, Jürgen F; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schmidt, Holger
2016-01-01
Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose-reduced datasets based on clinical (18)F-FDG PET data demonstrated the clinical applicability of the proposed data. Simulation of PET tracer dose reduction is possible with retrospective undersampling of list-mode data. Resulting simulated low-dose images have equivalent characteristics with PET images actually measured at lower doses and can be used to derive optimal tracer dose regimes.
Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System
Lassen, Martin L.; Muzik, Otto; Beyer, Thomas; Hacker, Marcus; Ladefoged, Claes Nøhr; Cal-González, Jacobo; Wadsak, Wolfgang; Rausch, Ivo; Langer, Oliver; Bauer, Martin
2017-01-01
The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET)-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R)-[11C]verapamil imaging on the same day using a GE-Advance (PET-only) and a Siemens Biograph mMR system (PET/MR). PET-emission data were reconstructed using a transmission-based attenuation correction (AC) map (PET-only), whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K1 and k2) and distribution volume (VT). Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA). Comparison of DIXON-based AC (PET/MR) with emission data derived from the PET-only system revealed average inter-system differences of −33 ± 14% (p < 0.05) for the K1 parameter and −19 ± 9% (p < 0.05) for k2. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of −16 ± 18% for K1 and −9 ± 10% for k2. The average differences in VT were −18 ± 10% (p < 0.05) for DIXON- and −8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods. Clinical Trial Registration: www.clinicaltrialsregister.eu, identifier 2013-001724-19 PMID:28769742
Injuries caused by pets in Asian urban households: a cross-sectional telephone survey
Chan, Emily Y Y; Gao, Yang; Li, Liping; Lee, Po Yi
2017-01-01
Objectives Little is known about pet-related injuries in Asian populations. This study primarily aimed to investigate the incidence rate of pet-related household injuries in Hong Kong, an urban Chinese setting. Setting Cantonese-speaking non-institutionalised population of all ages in Hong Kong accessible by telephone land-line. Participants A total of 43 542 telephone numbers were dialled and 6570 residents successfully completed the interviews. Primary and secondary outcome measures Data of pet-related household injuries in the previous 12 months, pet ownership and socio-demographic characteristics were collected with a questionnaire. Direct standardisation of the incidence rates of pet-related household injuries by gender and age to the 2009 Hong Kong Population Census was estimated. Univariate and multivariate analyses were performed to estimate risks of socio-demographic factors and pet ownership for the injury. Results A total of 84 participants experienced pet-related household injuries in the past 12 months, with an overall person-based incidence rate of 1.28%. The majority of the victims were injured once (69.6%). Cats (51.6%) were the most common pets involved. Pet owners were at an extremely higher risk after controlling for other factors (adjusted OR: 52.0, 95% CI 22.1 to 98.7). Females, the unmarried, those with higher monthly household income and those living in lower-density housing were more likely to be injured by pets. Conclusions We project a pet-related household injury incidence rate of 1.24% in the general Hong Kong population, with 86 334 residents sustaining pet-related injuries every year. Pet ownership puts people at extremely high risk, especially the unmarried. Further studies should focus on educating pet owners to reduce pet-related injuries in urban Greater China. PMID:28110284
Competitive Advantage of PET/MRI
Jadvar, Hossein; Colletti, Patrick M.
2013-01-01
Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. PMID:23791129
Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI
NASA Astrophysics Data System (ADS)
Harsha Maramraju, Sri; Smith, S. David; Junnarkar, Sachin S.; Schulz, Daniela; Stoll, Sean; Ravindranath, Bosky; Purschke, Martin L.; Rescia, Sergio; Southekal, Sudeepti; Pratte, Jean-François; Vaska, Paul; Woody, Craig L.; Schlyer, David J.
2011-04-01
We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 × 8 array of lutetium oxyorthosilicate crystals (2.22 × 2.22 × 5 mm3) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [11C]raclopride and 2-deoxy-2-[18F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.
Caprio, M G; Capacchione, D; Mainolfi, C; Spera, A M; Salvatore, B; Cella, L; Salvatore, M; Pace, L
2012-01-01
The aim was to compare the imaging findings of (18)F-fluorodeoxyglucose ((18)F-FDG) PET and integrated PET/CT in patients with primary, recurrent or metastatic ovarian cancer. 21 women with ovarian cancer were evaluated. All patients had a integrated PET/CT scan. Localization, infiltration and uptake intensity of [(18)F]FDG were evaluated on PET and PET/CT. The certainty of localisation and characterisation was scored on a 3 point scale (L1 definite localisation; L2 probable localisation; L3 uncertain localisation; C1 benign; C2 equivocal; C3 malignant). PET scored as L1 54 lesions (44%), as L2 51 (42%), and as L3 17 (14%). On the other hand, PET/CT scored as L1 120 lesions (98%), as L2 2 (2%), and none as L3. Thus PET/CT allowed a better localization in 54% of lesions. Moreover, PET scored as C1 25 lesions (20%), as C2 62 (51%), and as C3 35 (29%). On the other hand, PET/CT scored as C1 57 lesions (47%), as C2 13 (11%), and as C3 52 (42%). Thus PET/CT allowed a sensible reduction in the number of equivocal lesions (40%). Even when patients were subgrouped on the basis of clinical stage of the disease, PET/CT was capable of better definition of the lesions either for localization and for characterization. In patients with ovarian cancer, PET/CT allows better anatomical localisation of pathologic uptake providing high accuracy for staging and restaging of ovarian cancer when compared with PET alone.
Competitive advantage of PET/MRI.
Jadvar, Hossein; Colletti, Patrick M
2014-01-01
Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Treglia, Giorgio; Taralli, Silvia; Salsano, Marco; Muoio, Barbara; Sadeghi, Ramin; Giovanella, Luca
2014-06-01
The aim of the study was to meta-analyze published data about prevalence and malignancy risk of focal colorectal incidentalomas (FCIs) detected by Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography ((18)F-FDG-PET or PET/CT). A comprehensive computer literature search of studies published through July 31(st) 2012 regarding FCIs detected by (18)F-FDG-PET or PET/CT was performed. Pooled prevalence of patients with FCIs and risk of malignant or premalignant FCIs after colonoscopy or histopathology verification were calculated. Furthermore, separate calculations for geographic areas were performed. Finally, average standardized uptake values (SUV) in malignant, premalignant and benign FCIs were reported. Thirty-two studies comprising 89,061 patients evaluated by (18)F-FDG-PET or PET/CT were included. The pooled prevalence of FCIs detected by (18)F-FDG-PET or PET/CT was 3.6% (95% confidence interval [95% CI]: 2.6-4.7%). Overall, 1,044 FCIs detected by (18)F-FDG-PET or PET/CT underwent colonoscopy or histopathology evaluation. Pooled risk of malignant or premalignant lesions was 68% (95% CI: 60-75%). Risk of malignant and premalignant FCIs in Asia-Oceania was lower compared to that of Europe and America. A significant overlap in average SUV was found between malignant, premalignant and benign FCIs. FCIs are observed in a not negligible number of patients who undergo (18)F-FDG-PET or PET/CT studies with a high risk of malignant or premalignant lesions. SUV is not reliable as a tool to differentiate between malignant, premalignant and benign FCIs. Further investigation is warranted whenever FCIs are detected by (18)F-FDG-PET or PET/CT.
Treglia, Giorgio; Taralli, Silvia; Salsano, Marco; Muoio, Barbara; Sadeghi, Ramin; Giovanella, Luca
2014-01-01
Background The aim of the study was to meta-analyze published data about prevalence and malignancy risk of focal colorectal incidentalomas (FCIs) detected by Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography (18F-FDG-PET or PET/CT). Methods A comprehensive computer literature search of studies published through July 31st 2012 regarding FCIs detected by 18F-FDG-PET or PET/CT was performed. Pooled prevalence of patients with FCIs and risk of malignant or premalignant FCIs after colonoscopy or histopathology verification were calculated. Furthermore, separate calculations for geographic areas were performed. Finally, average standardized uptake values (SUV) in malignant, premalignant and benign FCIs were reported. Results Thirty-two studies comprising 89,061 patients evaluated by 18F-FDG-PET or PET/CT were included. The pooled prevalence of FCIs detected by 18F-FDG-PET or PET/CT was 3.6% (95% confidence interval [95% CI]: 2.6–4.7%). Overall, 1,044 FCIs detected by 18F-FDG-PET or PET/CT underwent colonoscopy or histopathology evaluation. Pooled risk of malignant or premalignant lesions was 68% (95% CI: 60–75%). Risk of malignant and premalignant FCIs in Asia-Oceania was lower compared to that of Europe and America. A significant overlap in average SUV was found between malignant, premalignant and benign FCIs. Conclusions FCIs are observed in a not negligible number of patients who undergo 18F-FDG-PET or PET/CT studies with a high risk of malignant or premalignant lesions. SUV is not reliable as a tool to differentiate between malignant, premalignant and benign FCIs. Further investigation is warranted whenever FCIs are detected by 18F-FDG-PET or PET/CT. PMID:24991198
Gulec, Seza A; Daghighian, Farhad; Essner, Richard
2016-12-01
Positron emission tomography (PET) has become an invaluable part of patient evaluation in surgical oncology. PET is less than optimal for detecting lesions <1 cm, and the intraoperative localization of small PET-positive lesions can be challenging as a result of difficulties in surgical exposure. We undertook this investigation to assess the utility of a handheld high-energy gamma probe (PET-Probe) for intraoperative identification of 18 F-deoxyglucose (FDG)-avid tumors. Forty patients underwent a diagnostic whole-body FDG-PET scan for consideration for surgical exploration and resection. Before surgery, all patients received an intravenous injection of 7 to 10 mCi of FDG. At surgery, the PET-Probe was used to determine absolute counts per second at the known tumor site(s) demonstrated by whole-body PET and at adjacent normal tissue (at least 4 cm away from tumor-bearing sites). Tumor-to-background ratios were calculated. Thirty-two patients (80%) underwent PET-Probe-guided surgery with therapeutic intent in a recurrent or metastatic disease setting. Eight patients underwent surgery for diagnostic exploration. Anatomical locations of the PET-identified lesions were neck and supraclavicular (n = 8), axilla (n = 5), groin and deep iliac (n = 4), trunk and extremity soft tissue (n = 3), abdominal and retroperitoneal (n = 19), and lung (n = 2). PET-Probe detected all PET-positive lesions. The PET-Probe was instrumental in localization of lesions in 15 patients that were not immediately apparent by surgical exploration. The PET-Probe identified all lesions demonstrated by PET scanning and, in selected cases, was useful in localizing FDG-avid disease not seen with conventional PET scanning.
Annunziata, Salvatore; Cuccaro, Annarosa; Tisi, Maria Chiara; Hohaus, Stefan; Rufini, Vittoria
2018-06-01
To retrospectively investigate the prognostic role of the ratio between target lesion and liver SUV max (rPET) in patients with follicular lymphoma (FL) submitted to FDG-PET/CT at the end of immuno-chemotherapy (PI-PET), and to compare rPET with International Harmonization Project criteria (IHP), Deauville Score (5p-DS) and FL International Prognostic Index at diagnosis (FLIPI). Eighty-nine patients with FL undergoing PI-PET were evaluated. The receiver operating characteristic (ROC) approach was applied to identify the optimal cut-point of rPET with respect to 5-years progression free survival (PFS). The prognostic significance of rPET was compared with IHP, DS and FLIPI. Positive predictive value (PPV) and negative predictive value (NPV) were calculated using the presence of adverse events as gold standard. The ROC analysis for rPET as predictor of progression showed an optimal rPET cut-point of 0.98. Patients with positive values of IHP, DS and rPET had a PFS of 50, 30 and 31%. PPV were of 56, 80 and 80%, NPV of 83, 86 and 88%, respectively. DS and rPET differed only in two patients. FLIPI was not predictive of progression and relapse. rPET is a prognostic factor in patients with FL submitted to PI-PET. Although it has a similar prognostic power as DS, it can have methodological advantages over visual analysis. PI-PET with different evaluation systems has a stronger prognostic power than FLIPI at diagnosis, so it could be useful to identify patients with FL at risk for early relapse after immuno-chemotherapy.
Westgarth, Carri; Heron, Jon; Ness, Andy R; Bundred, Peter; Gaskell, Rosalind M; Coyne, Karen P; German, Alexander J; McCune, Sandra; Dawson, Susan
2010-10-01
In developed nations, approximately half of household environments contain pets. Studies of Human-Animal Interaction (HAI) have proposed that there are health benefits and risks associated with pet ownership. However, accurately demonstrating and understanding these relationships first requires a better knowledge of factors associated with ownership of different pet types. A UK birth cohort, the Avon Longitudinal Study of Parents and Children (ALSPAC), were used to collect pet ownership data from the mothers, from gestation to child age 10 years old. 14,663 children were included in the study, of which mothers of 13,557 reported pet information at gestation, and 7,800 by age 10. Pet types recorded include cat, dog, rabbit, rodent, bird, fish and tortoise/turtle. The dataset also contains a number of demographic, socioeconomic and behavioural variables relevant to human health behaviour. Logistic regression was used to build multivariable models for ownership of each pet type at age 7 years. Family pet ownership increased during childhood, in particular rabbits, rodents and fish. A number of socioeconomic and demographic factors were associated with ownership of different pet types and the effects differed depending on the pet type studied. Variables which require consideration by researchers include gender, presence of older siblings, ethnicity, maternal and paternal education, maternal and paternal social class, maternal age, number of people in the household, house type, and concurrent ownership of other pets. Whether the mother had pets during her childhood was a strong predictor of pet ownership in all models. In HAI studies, care should be taken to control for confounding factors, and to treat each pet type individually. ALSPAC and other similar birth cohorts can be considered a potential resource for research into the effects of pet ownership during childhood.
Westgarth, Carri; Heron, Jon; Ness, Andy R.; Bundred, Peter; Gaskell, Rosalind M.; Coyne, Karen P.; German, Alexander J.; McCune, Sandra; Dawson, Susan
2010-01-01
In developed nations, approximately half of household environments contain pets. Studies of Human-Animal Interaction (HAI) have proposed that there are health benefits and risks associated with pet ownership. However, accurately demonstrating and understanding these relationships first requires a better knowledge of factors associated with ownership of different pet types. A UK birth cohort, the Avon Longitudinal Study of Parents and Children (ALSPAC), were used to collect pet ownership data from the mothers, from gestation to child age 10 years old. 14,663 children were included in the study, of which mothers of 13,557 reported pet information at gestation, and 7,800 by age 10. Pet types recorded include cat, dog, rabbit, rodent, bird, fish and tortoise/turtle. The dataset also contains a number of demographic, socioeconomic and behavioural variables relevant to human health behaviour. Logistic regression was used to build multivariable models for ownership of each pet type at age 7 years. Family pet ownership increased during childhood, in particular rabbits, rodents and fish. A number of socioeconomic and demographic factors were associated with ownership of different pet types and the effects differed depending on the pet type studied. Variables which require consideration by researchers include gender, presence of older siblings, ethnicity, maternal and paternal education, maternal and paternal social class, maternal age, number of people in the household, house type, and concurrent ownership of other pets. Whether the mother had pets during her childhood was a strong predictor of pet ownership in all models. In HAI studies, care should be taken to control for confounding factors, and to treat each pet type individually. ALSPAC and other similar birth cohorts can be considered a potential resource for research into the effects of pet ownership during childhood. PMID:21139856
Treglia, Giorgio; Mattoli, Maria Vittoria; Leccisotti, Lucia; Ferraccioli, Gianfranco; Giordano, Alessandro
2011-10-01
The objective of this study is to systematically review the role of positron emission tomography (PET) and PET/computed tomography (PET/CT) with fluorine-18-fluorodeoxyglucose (FDG) in patients with large-vessel vasculitis (LVV). A comprehensive literature search of published studies through April 2011 in PubMed/MEDLINE and Scopus databases regarding whole-body FDG-PET and PET/CT in patients with LVV was performed. We identified 32 studies including 604 LVV patients. The main findings of these studies are presented. The conclusions are the following: (1) FDG-PET and PET/CT are useful imaging methods in the initial diagnosis and in the assessment of activity and extent of disease in patients with LVV; (2) the correlation between FDG-PET findings and serological levels of inflammatory markers, as well as the usefulness of FDG-PET and PET/CT in evaluating treatment response, remains unclear; (3) it appears that there is a superiority of FDG-PET and PET/CT over conventional imaging methods in the diagnosis of LVV, but not in assessing disease activity under immunosuppressive treatment, in predicting relapse or in evaluating vascular complications; and (4) given the heterogeneity between studies with regard to PET analysis and diagnostic criteria, a standardization of the technique is needed.
Deformation field correction for spatial normalization of PET images
Bilgel, Murat; Carass, Aaron; Resnick, Susan M.; Wong, Dean F.; Prince, Jerry L.
2015-01-01
Spatial normalization of positron emission tomography (PET) images is essential for population studies, yet the current state of the art in PET-to-PET registration is limited to the application of conventional deformable registration methods that were developed for structural images. A method is presented for the spatial normalization of PET images that improves their anatomical alignment over the state of the art. The approach works by correcting the deformable registration result using a model that is learned from training data having both PET and structural images. In particular, viewing the structural registration of training data as ground truth, correction factors are learned by using a generalized ridge regression at each voxel given the PET intensities and voxel locations in a population-based PET template. The trained model can then be used to obtain more accurate registration of PET images to the PET template without the use of a structural image. A cross validation evaluation on 79 subjects shows that the proposed method yields more accurate alignment of the PET images compared to deformable PET-to-PET registration as revealed by 1) a visual examination of the deformed images, 2) a smaller error in the deformation fields, and 3) a greater overlap of the deformed anatomical labels with ground truth segmentations. PMID:26142272
Spick, Claudio; Herrmann, Ken; Czernin, Johannes
2016-01-01
18F-FDG PET/CT has become the reference standard in oncologic imaging against which the performance of other imaging modalities is measured. The promise of PET/MRI includes multiparametric imaging to further improve diagnosis and phenotyping of cancer. Rather than focusing on these capabilities, many investigators have examined whether 18F-FDG PET combined with mostly anatomic MRI improves cancer staging and restaging. After a description of PET/MRI scanner designs and a discussion of technical and operational issues, we review the available literature to determine whether cancer assessments are improved with PET/MRI. The available data show that PET/MRI is feasible and performs as well as PET/CT in most types of cancer. Diagnostic advantages may be achievable in prostate cancer and in bone metastases, whereas disadvantages exist in lung nodule assessments. We conclude that 18F-FDG PET/MRI and PET/CT provide comparable diagnostic information when MRI is used simply to provide the anatomic framework. Thus, PET/MRI could be used in lieu of PET/CT if this approach becomes economically viable and if reasonable workflows can be established. Future studies should explore the multiparametric potential of MRI. PMID:26742709
Sun, Yajuan; Yu, Hongjuan; Ma, Jingquan
2016-01-01
Objective The aim of our study was to evaluate the role of 18F-FDG PET/CT integrated imaging in differentiating malignant from benign pleural effusion. Methods A total of 176 patients with pleural effusion who underwent 18F-FDG PET/CT examination to differentiate malignancy from benignancy were retrospectively researched. The images of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were visually analyzed. The suspected malignant effusion was characterized by the presence of nodular or irregular pleural thickening on CT imaging. Whereas on PET imaging, pleural 18F-FDG uptake higher than mediastinal activity was interpreted as malignant effusion. Images of 18F-FDG PET/CT integrated imaging were interpreted by combining the morphologic feature of pleura on CT imaging with the degree and form of pleural 18F-FDG uptake on PET imaging. Results One hundred and eight patients had malignant effusion, including 86 with pleural metastasis and 22 with pleural mesothelioma, whereas 68 patients had benign effusion. The sensitivities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging in detecting malignant effusion were 75.0%, 91.7% and 93.5%, respectively, which were 69.8%, 91.9% and 93.0% in distinguishing metastatic effusion. The sensitivity of 18F-FDG PET/CT integrated imaging in detecting malignant effusion was higher than that of CT imaging (p = 0.000). For metastatic effusion, 18F-FDG PET imaging had higher sensitivity (p = 0.000) and better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with CT imaging (Kappa = 0.917 and Kappa = 0.295, respectively). The specificities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were 94.1%, 63.2% and 92.6% in detecting benign effusion. The specificities of CT imaging and 18F-FDG PET/CT integrated imaging were higher than that of 18F-FDG PET imaging (p = 0.000 and p = 0.000, respectively), and CT imaging had better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with 18F-FDG PET imaging (Kappa = 0.881 and Kappa = 0.240, respectively). Conclusion 18F-FDG PET/CT integrated imaging is a more reliable modality in distinguishing malignant from benign pleural effusion than 18F-FDG PET imaging and CT imaging alone. For image interpretation of 18F-FDG PET/CT integrated imaging, the PET and CT portions play a major diagnostic role in identifying metastatic effusion and benign effusion, respectively. PMID:27560933
Alpha Recoil Flux of Radon in Groundwater and its Experimental Measurement
NASA Astrophysics Data System (ADS)
Mehta, N.; Harvey, C. F.; Kocar, B. D.
2016-12-01
Groundwater Radon (Rn222) activity is primarily controlled by alpha recoil process (radioactive decay), however, evaluating the rate and extent of this process, and its impact on porewater radioactivity, remains uncertain. Numerous factors contribute to this uncertainty, including the spatial distribution of parent radionuclides (e.g. U238, Th232 , Ra226 and Ra228) within native materials, differences in nuclide recoil length in host matrix and the physical structure of the rock strata (pore size distribution and porosity). Here, we experimentally measure Radon activities within porewater contributed through alpha recoil, and analyze its variations as a function of pore structure and parent nuclide distribution within host matrices, including Marcellus shale rock and Serrie-Copper Pegmatite. The shale cores originate from the Marcellus formation in Mckean, Pennsylvania collected at depths ranging from 1000-7000 feet, and the U-Th-rich Pegmatite is obtained from South Platte District, Colorado. Columns are packed with granulated rock of varying surface area (30,000-60,000 cm2/g) and subjected to low salinity sodium chloride solution in a close loop configuration. The activity of Radon (Rn222) and radium (Ra226) in the saline fluid is measured over time to determine recoil supply rates. Mineralogical and trace element data for rock specimens are characterized using XRD and XRF, and detailed geochemical profiles are constructed through total dissolution and analysis using ICP-MS and ICP-OES. Naturally occurring Radium nuclides and its daughters are quantified using a low-energy Germanium detector. The parent nuclide (U238 and Th232) distribution in the host rock is studied using X-Ray Absorption Spectroscopy (XAS). Our study elucidates the contribution of alpha recoil on the appearance and distribution of Radon (Rn222) within porewater of representative rock matrices. Further, we illustrate the effects of chemical and physical heterogeneity on the rate of this process, which may inform models predicting the fate and transport of radionuclides in subsurface environments.
Myths and misperceptions about ingredients used in commercial pet foods.
Laflamme, Dottie; Izquierdo, Oscar; Eirmann, Laura; Binder, Stephen
2014-07-01
Information and misinformation about pet nutrition and pet foods, including ingredients used in pet foods, is widely available through various sources. Often, this "information" raises questions or concerns among pet owners. Many pet owners will turn to their veterinarian for answers to these questions. One of the challenges that veterinarians have is keeping up with the volume of misinformation about pet foods and sorting out fact from fiction. The goal of this article is to provide facts regarding some common myths about ingredients used in commercial pet foods so as to better prepare veterinarians to address their client's questions. Copyright © 2014 Elsevier Inc. All rights reserved.
Quartuccio, Natale; Treglia, Giorgio; Salsano, Marco; Mattoli, Maria Vittoria; Muoio, Barbara; Piccardo, Arnoldo; Lopci, Egesta; Cistaro, Angelina
2013-01-01
Background The objective of this study is to systematically review the role of positron emission tomography (PET) and PET/computed tomography (PET/CT) with Fluorine-18-Fluorodeoxyglucose (FDG) in patients with osteosarcoma (OS). Methods A comprehensive literature search of published studies through October 10th, 2012 in PubMed/MEDLINE, Embase and Scopus databases regarding whole-body FDG-PET and FDG-PET/CT in patients with OS was performed. Results We identified 13 studies including 289 patients with OS. With regard to the staging and restaging of OS, the diagnostic performance of FDG-PET and PET/CT seem to be high; FDG-PET and PET/CT seem to be superior to bone scintigraphy and conventional imaging methods in detecting bone metastases; conversely, spiral CT seems to be superior to FDG-PET in detecting pulmonary metastases from OS Conclusions Metabolic imaging may provide additional information in the evaluation of OS patients. The combination of FDG-PET or FDG-PET/CT with conventional imaging methods seems to be a valuable tool in the staging and restaging of OS and may have a relevant impact on the treatment planning. PMID:23801904
Spadafora, Marco; Pace, Leonardo; Evangelista, Laura; Mansi, Luigi; Del Prete, Francesco; Saladini, Giorgio; Miletto, Paolo; Fanti, Stefano; Del Vecchio, Silvana; Guerra, Luca; Pepe, Giovanna; Peluso, Giuseppina; Nicolai, Emanuele; Storto, Giovanni; Ferdeghini, Marco; Giordano, Alessandro; Farsad, Mohsen; Schillaci, Orazio; Gridelli, Cesare; Cuocolo, Alberto
2018-05-05
Diagnosis of solitary pulmonary nodule (SPN) is an important public health issue and 18 F-FDG PET/CT has proven to be more effective than CT alone. Pre-test risk stratification and clinical presentation of SPN could affect the diagnostic strategy. A relevant issue is whether thoracic segmental (s)-PET/CT could be implemented in patients with SPN. This retrospective multicenter study compared the results of FDG whole-body (wb)-PET/CT to those of s-PET/CT. 18 F-FDG PET/CT of 502 patients, stratified for pre-test cancer risk, were retrospectively analyzed. The thoracic part of wb-PET/CT, considered s-PET/CT, was compared to wb-PET/CT. Clinical and PET/CT variables were investigated for SPN characterization as well as for identification of patients in whom s-PET/CT could be performed. Histopathology or follow-up data were used as a reference. In the study population, 36% had malignant, 35% benign, and 29% indeterminate SPN. 18 F-FDG uptake indicative of thoracic and extra-thoracic lesions was detectable in 13% and 3% of the patients. All patients with extra-thoracic metastases (n = 13) had thoracic lymph node involvement and highest 18 F-FDG uptake at level of SPN (negative predictive value 100%). Compared to wb-PET/CT, s-PET/CT could save about 2/3 of 18 F-FDG dose, radiation exposure or scan-time, without affecting the clinical impact of PET/CT. Pre-test probability of malignancy can guide the diagnostic strategy of 18 FDG-PET/CT in patients with SPN. In subjects with low-intermediate pretest probability s-PET/CT imaging might be planned in advance, while in those at high risk and with thoracic lymph node involvement a wb-PET/CT is necessary.
Ryvlin, P; Bouvard, S; Le Bars, D; De Lamérie, G; Grégoire, M C; Kahane, P; Froment, J C; Mauguière, F
1998-11-01
We assessed the clinical utility of [11C]flumazenil-PET (FMZ-PET) prospectively in 100 epileptic patients undergoing a pre-surgical evaluation, and defined the specific contribution of this neuro-imaging technique with respect to those of MRI and [18F]fluorodeoxyglucose-PET (FDG-PET). All patients benefited from a long term video-EEG monitoring, whereas an intracranial EEG investigation was performed in 40 cases. Most of our patients (73%) demonstrated a FMZ-PET abnormality; this hit rate was significantly higher in temporal lobe epilepsy (94%) than in other types of epilepsy (50%) (P < 0.001). Most FMZ-PET findings coexisted with a MRI abnormality (81%), including hippocampal atrophy (35%) and focal hypometabolism on FDG-PET (89%). The area of decreased FMZ binding was often smaller than that of glucose hypometabolism (48%) or larger than that of the MRI abnormality (28%). FMZ-PET did not prove superior to FDG-PET in assessing the extent of the ictal onset zone, as defined by intracranial EEG recordings. However, it provided useful data which were complementary to those of MRI and FDG-PET in three situations: (i) in temporal lobe epilepsy associated with MRI signs of hippocampal sclerosis, FMZ-PET abnormalities delineated the site of seizure onset precisely, whenever they were coextensive with FDG-PET abnormalities; (ii) in bi-temporal epilepsy, FMZ-PET helped to confirm the bilateral origin of seizures by showing a specific pattern of decreased FMZ binding in both temporal lobes in 33% of cases; (iii) in patients with a unilateral cryptogenic frontal lobe epilepsy, FMZ-PET provided further evidence of the side and site of seizure onset in 55% of cases. Thus, FMZ-PET deserves to be included in the pre-surgical evaluation of these specific categories of epileptic patients, representing approximately half of the population considered for epilepsy surgery.
Ghaneh, Paula; Hanson, Robert; Titman, Andrew; Lancaster, Gill; Plumpton, Catrin; Lloyd-Williams, Huw; Yeo, Seow Tien; Edwards, Rhiannon Tudor; Johnson, Colin; Abu Hilal, Mohammed; Higginson, Antony P; Armstrong, Tom; Smith, Andrew; Scarsbrook, Andrew; McKay, Colin; Carter, Ross; Sutcliffe, Robert P; Bramhall, Simon; Kocher, Hemant M; Cunningham, David; Pereira, Stephen P; Davidson, Brian; Chang, David; Khan, Saboor; Zealley, Ian; Sarker, Debashis; Al Sarireh, Bilal; Charnley, Richard; Lobo, Dileep; Nicolson, Marianne; Halloran, Christopher; Raraty, Michael; Sutton, Robert; Vinjamuri, Sobhan; Evans, Jonathan; Campbell, Fiona; Deeks, Jon; Sanghera, Bal; Wong, Wai-Lup; Neoptolemos, John P
2018-02-01
Pancreatic cancer diagnosis and staging can be difficult in 10-20% of patients. Positron emission tomography (PET)/computed tomography (CT) adds precise anatomical localisation to functional data. The use of PET/CT may add further value to the diagnosis and staging of pancreatic cancer. To determine the incremental diagnostic accuracy and impact of PET/CT in addition to standard diagnostic work-up in patients with suspected pancreatic cancer. A multicentre prospective diagnostic accuracy and clinical value study of PET/CT in suspected pancreatic malignancy. Patients with suspected pancreatic malignancy. All patients to undergo PET/CT following standard diagnostic work-up. The primary outcome was the incremental diagnostic value of PET/CT in addition to standard diagnostic work-up with multidetector computed tomography (MDCT). Secondary outcomes were (1) changes in patients' diagnosis, staging and management as a result of PET/CT; (2) changes in the costs and effectiveness of patient management as a result of PET/CT; (3) the incremental diagnostic value of PET/CT in chronic pancreatitis; (4) the identification of groups of patients who would benefit most from PET/CT; and (5) the incremental diagnostic value of PET/CT in other pancreatic tumours. Between 2011 and 2013, 589 patients with suspected pancreatic cancer underwent MDCT and PET/CT, with 550 patients having complete data and in-range PET/CT. Sensitivity and specificity for the diagnosis of pancreatic cancer were 88.5% and 70.6%, respectively, for MDCT and 92.7% and 75.8%, respectively, for PET/CT. The maximum standardised uptake value (SUV max. ) for a pancreatic cancer diagnosis was 7.5. PET/CT demonstrated a significant improvement in relative sensitivity ( p = 0.01) and specificity ( p = 0.023) compared with MDCT. Incremental likelihood ratios demonstrated that PET/CT significantly improved diagnostic accuracy in all scenarios ( p < 0.0002). PET/CT correctly changed the staging of pancreatic cancer in 56 patients ( p = 0.001). PET/CT influenced management in 250 (45%) patients. PET/CT stopped resection in 58 (20%) patients who were due to have surgery. The benefit of PET/CT was limited in patients with chronic pancreatitis or other pancreatic tumours. PET/CT was associated with a gain in quality-adjusted life-years of 0.0157 (95% confidence interval -0.0101 to 0.0430). In the base-case model PET/CT was seen to dominate MDCT alone and is thus highly likely to be cost-effective for the UK NHS. PET/CT was seen to be most cost-effective for the subgroup of patients with suspected pancreatic cancer who were thought to be resectable. PET/CT provided a significant incremental diagnostic benefit in the diagnosis of pancreatic cancer and significantly influenced the staging and management of patients. PET/CT had limited utility in chronic pancreatitis and other pancreatic tumours. PET/CT is likely to be cost-effective at current reimbursement rates for PET/CT to the UK NHS. This was not a randomised controlled trial and therefore we do not have any information from patients who would have undergone MDCT only for comparison. In addition, there were issues in estimating costs for PET/CT. Future work should evaluate the role of PET/CT in intraductal papillary mucinous neoplasm and prognosis and response to therapy in patients with pancreatic cancer. Current Controlled Trials ISRCTN73852054 and UKCRN 8166. The National Institute for Health Research Health Technology Assessment programme.
Gong, Kuang; Cheng-Liao, Jinxiu; Wang, Guobao; Chen, Kevin T; Catana, Ciprian; Qi, Jinyi
2018-04-01
Positron emission tomography (PET) is a functional imaging modality widely used in oncology, cardiology, and neuroscience. It is highly sensitive, but suffers from relatively poor spatial resolution, as compared with anatomical imaging modalities, such as magnetic resonance imaging (MRI). With the recent development of combined PET/MR systems, we can improve the PET image quality by incorporating MR information into image reconstruction. Previously, kernel learning has been successfully embedded into static and dynamic PET image reconstruction using either PET temporal or MRI information. Here, we combine both PET temporal and MRI information adaptively to improve the quality of direct Patlak reconstruction. We examined different approaches to combine the PET and MRI information in kernel learning to address the issue of potential mismatches between MRI and PET signals. Computer simulations and hybrid real-patient data acquired on a simultaneous PET/MR scanner were used to evaluate the proposed methods. Results show that the method that combines PET temporal information and MRI spatial information adaptively based on the structure similarity index has the best performance in terms of noise reduction and resolution improvement.
Mughini Gras, L; Smid, J H; Wagenaar, J A; Koene, M G J; Havelaar, A H; Friesema, I H M; French, N P; Flemming, C; Galson, J D; Graziani, C; Busani, L; VAN Pelt, W
2013-12-01
We compared Campylobacter jejuni/coli multilocus sequence types (STs) from pets (dogs/cats) and their owners and investigated risk factors for pet-associated human campylobacteriosis using a combined source-attribution and case-control analysis. In total, 132/687 pet stools were Campylobacter-positive, resulting in 499 strains isolated (320 C. upsaliensis/helveticus, 100 C. jejuni, 33 C. hyointestinalis/fetus, 10 C. lari, 4 C. coli, 32 unidentified). There were 737 human and 104 pet C. jejuni/coli strains assigned to 154 and 49 STs, respectively. Dog, particularly puppy, owners were at increased risk of infection with pet-associated STs. In 2/68 cases vs. 0.134/68 expected by chance, a pet and its owner were infected with an identical ST (ST45, ST658). Although common sources of infection and directionality of transmission between pets and humans were unknown, dog ownership significantly increased the risk for pet-associated human C. jejuni/coli infection and isolation of identical strains in humans and their pets occurred significantly more often than expected.
The Spillover Effect of a Flood on Pets and Their People: Implications for Rental Housing.
Graham, Taryn M; Rock, Melanie J
2018-06-04
When disasters strike, companion animals (pets) matter. Emergency planning for them is a key aspect of disaster preparedness, especially considering that people may delay evacuation out of concern for their pets. Temporary boarding options for pets are important; however, caregivers (owners) must ultimately return to permanent housing. Surprisingly little attention has been paid to housing recovery in the disaster literature on pet ownership, and no studies have examined the potential for increased vulnerability among tenants with pets. This study analyzed online rental listings in a city that was severely flooded in 2013. In the following year, demand for pet-friendly rental housing outweighed supply. Landlords frequently stipulated restrictions on the allowable sizes, species, or breeds of pets. Dogs were often banned outright. To keep their pets, prospective tenants needed to exercise flexibility in location and pay higher surcharges. The implications of housing insecurity for tenants with pets have broad relevance, not just in disaster circumstances. Giving up a companion animal to secure housing can negatively impact resilience, whereas living in unsafe environments to avoid pet relinquishment may increase vulnerability.
Pet ownership increases human risk of encountering ticks.
Jones, E H; Hinckley, A F; Hook, S A; Meek, J I; Backenson, B; Kugeler, K J; Feldman, K A
2018-02-01
We examined whether pet ownership increased the risk for tick encounters and tickborne disease among residents of three Lyme disease-endemic states as a nested cohort within a randomized controlled trial. Information about pet ownership, use of tick control for pets, property characteristics, tick encounters and human tickborne disease were captured through surveys, and associations were assessed using univariate and multivariable analyses. Pet-owning households had 1.83 times the risk (95% CI = 1.53, 2.20) of finding ticks crawling on and 1.49 times the risk (95% CI = 1.20, 1.84) of finding ticks attached to household members compared to households without pets. This large evaluation of pet ownership, human tick encounters and tickborne diseases shows that pet owners, whether of cats or dogs, are at increased risk of encountering ticks and suggests that pet owners are at an increased risk of developing tickborne disease. Pet owners should be made aware of this risk and be reminded to conduct daily tick checks of all household members, including the pets, and to consult their veterinarian regarding effective tick control products. © 2017 Blackwell Verlag GmbH.
Parslow, Ruth A; Jorm, Anthony F; Christensen, Helen; Rodgers, Bryan; Jacomb, Patricia
2005-01-01
It is commonly assumed that owning a pet provides older residents in the community with health benefits including improved physical health and psychological well-being. It has also been reported that pet owners are lower on neuroticism and higher on extraversion compared with those without pets. However, findings of research on this topic have been mixed with a number of researchers reporting that, for older people, there is little or no health benefit associated with pet ownership. To identify health benefits associated with pet ownership and pet caring responsibilities in a large sample of older community-based residents. Using survey information provided by 2,551 individuals aged between 60 and 64 years, we compared the sociodemographic attributes, mental and physical health measures, and personality traits of pet owners and non-owners. For 78.8% of these participants, we were also able to compare the health services used, based on information obtained from the national insurer on the number of general practitioner (GP) visits they made over a 12-month period. Compared with non-owners, those with pets reported more depressive symptoms while female pet owners who were married also had poorer physical health. We found that caring for a pet was associated with negative health outcomes including more symptoms of depression, poorer physical health and higher rates of use of pain relief medication. No relationship was found between pet ownership and use of GP services. When we examined the personality traits of pet owners and carers, we found that men who cared for pets had higher extraversion scores. Our principal and unexpected finding, however, was that pet owners and carers reported higher levels of psychoticism as measured by the Revised Eysenck Personality Questionnaire. We conclude that pet ownership confers no health benefits for this age group. Instead, those with pets have poorer mental and physical health and use more pain relief medication. Further, our study suggests that those with pets are less conforming to social norms as indicated by their higher levels of psychoticism. Copyright (c) 2005 S. Karger AG, Basel
Eiber, Matthias; Martinez-Möller, Axel; Souvatzoglou, Michael; Holzapfel, Konstantin; Pickhard, Anja; Löffelbein, Dennys; Santi, Ivan; Rummeny, Ernst J; Ziegler, Sibylle; Schwaiger, Markus; Nekolla, Stephan G; Beer, Ambros J
2011-09-01
In this study, the potential contribution of Dixon-based MR imaging with a rapid low-resolution breath-hold sequence, which is a technique used for MR-based attenuation correction (AC) for MR/positron emission tomography (PET), was evaluated for anatomical correlation of PET-positive lesions on a 3T clinical scanner compared to low-dose CT. This technique is also used in a recently installed fully integrated whole-body MR/PET system. Thirty-five patients routinely scheduled for oncological staging underwent (18)F-fluorodeoxyglucose (FDG) PET/CT and a 2-point Dixon 3-D volumetric interpolated breath-hold examination (VIBE) T1-weighted MR sequence on the same day. Two PET data sets reconstructed using attenuation maps from low-dose CT (PET(AC_CT)) or simulated MR-based segmentation (PET(AC_MR)) were evaluated for focal PET-positive lesions. The certainty for the correlation with anatomical structures was judged in the low-dose CT and Dixon-based MRI on a 4-point scale (0-3). In addition, the standardized uptake values (SUVs) for PET(AC_CT) and PET(AC_MR) were compared. Statistically, no significant difference could be found concerning anatomical localization for all 81 PET-positive lesions in low-dose CT compared to Dixon-based MR (mean 2.51 ± 0.85 and 2.37 ± 0.87, respectively; p = 0.1909). CT tended to be superior for small lymph nodes, bone metastases and pulmonary nodules, while Dixon-based MR proved advantageous for soft tissue pathologies like head/neck tumours and liver metastases. For the PET(AC_CT)- and PET(AC_MR)-based SUVs (mean 6.36 ± 4.47 and 6.31 ± 4.52, respectively) a nearly complete concordance with a highly significant correlation was found (r = 0.9975, p < 0.0001). Dixon-based MR imaging for MR AC allows for anatomical allocation of PET-positive lesions similar to low-dose CT in conventional PET/CT. Thus, this approach appears to be useful for future MR/PET for body regions not fully covered by diagnostic MRI due to potential time constraints.
Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L
2014-12-01
The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.
Mhlanga, Joyce C.; Carrino, John A.; Lodge, Martin; Wang, Hao
2015-01-01
Purpose The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with 18F-FDG. Methods Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological 18F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Results Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73±7.7 years). Six patients served as the control group (53.7±9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r=0.86. p =0.007; r=0.94, p=0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7±6.6 vs. 32.2±0.4, p=0.02; 37.5±5.4 vs. 32.2±0.4, p=0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8±4.2 vs. 18±1.8, p= 0.13; 22.8±5.38 vs. 20.1±1.54, p=0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9±31.3 vs. 0, p=0.03). Conclusion Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. PMID:25134669
Pet ownership, dog types and attachment to pets in 9–10 year old children in Liverpool, UK
2013-01-01
Background Little is known about ethnic, cultural and socioeconomic differences in childhood ownership and attitudes to pets. The objective of this study was to describe the factors associated with living with different pet types, as well as factors that may influence the intensity of relationship or ‘attachment’ that children have to their pet. Data were collected using a survey of 1021 9–10 year old primary school children in a deprived area of the city of Liverpool, UK. Results Dogs were the most common pet owned, most common ‘favourite’ pet, and species most attached to. Twenty-seven percent of dog-owning children (10% of all children surveyed) reported living with a ‘Bull Breed’ dog (which includes Pit Bulls and Staffordshire Bull Terriers), and the most popular dog breed owned was the Staffordshire Bull Terrier. Multivariable regression modelling identified a number of variables associated with ownership of different pets and the strength of attachment to the child’s favourite pet. Girls were more likely to own most pet types, but were no more or less attached to their favourite pet than boys. Children of white ethnicity were more likely to own dogs, rodents and ‘other’ pets but were no more or less attached to their pets than children of non-white ethnicity. Single and youngest children were no more or less likely to own pets than those with younger brothers and sisters, but they showed greater attachment to their pets. Children that owned dogs lived in more deprived areas than those without dogs, and deprivation increased with number of dogs owned. ‘Pit Bull or cross’ and ‘Bull Breed’ dogs were more likely to be found in more deprived areas than other dog types. Non-whites were also more likely to report owning a ‘Pit Bull or cross’ than Whites. Conclusions Gender, ethnicity and socioeconomic status were associated with pet ownership, and sibling status with level of attachment to the pet. These are important to consider when conducting research into the health benefits and risks of the common childhood phenomenon of growing up with pets. PMID:23668544
Pet ownership, dog types and attachment to pets in 9-10 year old children in Liverpool, UK.
Westgarth, Carri; Boddy, Lynne M; Stratton, Gareth; German, Alexander J; Gaskell, Rosalind M; Coyne, Karen P; Bundred, Peter; McCune, Sandra; Dawson, Susan
2013-05-13
Little is known about ethnic, cultural and socioeconomic differences in childhood ownership and attitudes to pets. The objective of this study was to describe the factors associated with living with different pet types, as well as factors that may influence the intensity of relationship or 'attachment' that children have to their pet. Data were collected using a survey of 1021 9-10 year old primary school children in a deprived area of the city of Liverpool, UK. Dogs were the most common pet owned, most common 'favourite' pet, and species most attached to. Twenty-seven percent of dog-owning children (10% of all children surveyed) reported living with a 'Bull Breed' dog (which includes Pit Bulls and Staffordshire Bull Terriers), and the most popular dog breed owned was the Staffordshire Bull Terrier. Multivariable regression modelling identified a number of variables associated with ownership of different pets and the strength of attachment to the child's favourite pet. Girls were more likely to own most pet types, but were no more or less attached to their favourite pet than boys. Children of white ethnicity were more likely to own dogs, rodents and 'other' pets but were no more or less attached to their pets than children of non-white ethnicity. Single and youngest children were no more or less likely to own pets than those with younger brothers and sisters, but they showed greater attachment to their pets. Children that owned dogs lived in more deprived areas than those without dogs, and deprivation increased with number of dogs owned. 'Pit Bull or cross' and 'Bull Breed' dogs were more likely to be found in more deprived areas than other dog types. Non-whites were also more likely to report owning a 'Pit Bull or cross' than Whites. Gender, ethnicity and socioeconomic status were associated with pet ownership, and sibling status with level of attachment to the pet. These are important to consider when conducting research into the health benefits and risks of the common childhood phenomenon of growing up with pets.
Treglia, Giorgio; Annunziata, Salvatore; Muoio, Barbara; Salvatori, Massimo; Ceriani, Luca; Giovanella, Luca
2013-01-01
Aggressive histological subtypes of thyroid cancer are rare and have a poor prognosis. The most important aggressive subtypes of thyroid cancer are Hürthle cell carcinoma (HCTC) and anaplastic and poorly differentiated carcinoma (ATC and PDTC). The American Thyroid Association recently published guidelines for the management of patients with ATC, but no specific guidelines have been done about HCTC. We performed an overview of the literature about the role of Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography (FDG-PET or PET/CT) in aggressive histological subtypes of thyroid cancer. Only few original studies about the role of FDG-PET or PET/CT in HCTC, PDTC, and ATC have been published in the literature. FDG-PET or PET/CT seems to be useful in staging or followup of invasive and metastatic HCTC. FDG-PET or PET/CT should be used in patients with ATC in initial staging and in the followup after surgery to evaluate metastatic disease. Some authors suggest the use of FDG-PET/CT in staging of PDTC, but more studies are needed to define the diagnostic use of FDG-PET/CT in this setting. Limited experience suggests the usefulness of FDG-PET or PET/CT in patients with more aggressive histological subtypes of DTC. However, DTC presenting as radioiodine refractory and FDG-PET positive should be considered aggressive tumours with poor prognosis.
Pets for Handicapped Children.
ERIC Educational Resources Information Center
Frith, Greg H.
1982-01-01
Pets can provide valuable learning for handicapped children, but selection of a type of pet should consider cost, availability and care, parents' attitudes, locality, the animal's susceptibility to training, pet's life expectancy, and the child's handicap and emotional maturity. Suggested pet-related activities are listed. (CL)
Wells, M; Perrine, R
2001-01-01
This article reports the findings of an exploratory study examining the perceived functions and psychological and organizational effects of pets in the workplace. Participants were 193 employees from 31 companies allowing pets in the workplace who completed anonymous questionnaires. Results indicated that participants perceived pets in the workplace to reduce stress and to positively affect employee health and the organization. Participants who brought their pets to work perceived greater benefits than participants who did not bring their pets to work and participants who did not own pets.
Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S
2016-01-01
AIM: To describe our preliminary experience with simultaneous whole body 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. METHODS: This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated 18F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. RESULTS: A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than that of benign lesions (1246.2 + 417.3; P = 0.0003; Student’s t test). A range of ADCmin thresholds for malignancy were evaluated, from 0.5-1.5 × 10-3 mm2/s. The 1.0 × 10-3 ADCmin threshold performed best compared with PET-CT reference (68.3% accuracy). However, the accuracy of PET-MRI SUVmax was significantly better than ADCmin for detecting malignant lesions compared with PET-CT reference (P < 0.0001; two-tailed McNemar’s test). CONCLUSION: These results suggest a clinical role for simultaneous whole body PET-MRI in evaluating pediatric cancer patients. PMID:27028112
Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S
2016-03-28
To describe our preliminary experience with simultaneous whole body (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated (18)F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than that of benign lesions (1246.2 + 417.3; P = 0.0003; Student's t test). A range of ADCmin thresholds for malignancy were evaluated, from 0.5-1.5 × 10(-3) mm(2)/s. The 1.0 × 10(-3) ADCmin threshold performed best compared with PET-CT reference (68.3% accuracy). However, the accuracy of PET-MRI SUVmax was significantly better than ADCmin for detecting malignant lesions compared with PET-CT reference (P < 0.0001; two-tailed McNemar's test). These results suggest a clinical role for simultaneous whole body PET-MRI in evaluating pediatric cancer patients.
Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jung, Jin Ho; Choi, Yong, E-mail: ychoi.image@gmail.com; Jung, Jiwoong
2015-05-15
Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. Themore » PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was maintained. The change of gain of the 256 GAPD/scintillator elements of a detector block was <3% for 60 min, and simultaneous PET and MR images of a brain phantom were successfully acquired. Conclusions: Experimental results indicate that a compact and lightweight PET insert for hybrid PET/MRI can be developed using GAPD arrays and charge signal transmission method proposed in this study without significant interference.« less
Fantoni, Enrico R; Chalkidou, Anastasia; O' Brien, John T; Farrar, Gill; Hammers, Alexander
2018-01-01
Amyloid PET (aPET) imaging could improve patient outcomes in clinical practice, but the extent of impact needs quantification. To provide an aggregated quantitative analysis of the value added by aPET in cognitively impaired subjects. Systematic literature searches were performed in Embase and Medline until January 2017. 1,531 cases over 12 studies were included (1,142 cases over seven studies in the primary analysis where aPET was the key biomarker; the remaining cases included as defined groups in the secondary analysis). Data was abstracted by consensus among two observers and assessed for bias. Clinical utility was measured by diagnostic change, diagnostic confidence, and patient management before and after aPET. Three groups were further analyzed: control patients for whom feedback of aPET scan results was delayed; aPET Appropriate Use Criteria (AUC+) cases; and patients undergoing additional FDG/CSF testing. For 1,142 cases with only aPET, 31.3% of diagnoses were revised, whereas 3.2% of diagnoses changed in the delayed aPET control group (p < 0.0001). Increased diagnostic confidence following aPET was found for 62.1% of 870 patients. Management changes with aPET were found in 72.2% of 740 cases and in 55.5% of 299 cases in the control group (p < 0.0001). The diagnostic value of aPET in AUC+ patients or when FDG/CSF were additionally available did not substantially differ from the value of aPET alone in the wider population. Amyloid PET contributed to diagnostic revision in almost a third of cases and demonstrated value in increasing diagnostic confidence and refining management plans.
Guerra-García, Pilar; Hirsch, Steffen; Levine, Daniel S; Taj, Mary M
2017-12-01
Post-transplant lymphoproliferative disorder (PTLD) is a well-known complication following prolonged immunosuppression. Contrary to other lymphomas, there is no standardized imaging approach to assess PTLD either at staging or for response to therapy. Positron emission tomography/computed tomography (PET/CT) is an imaging modality that has proven to be useful in lymphoma. However, there is still limited data concerning its use in pediatric PTLD. Our study evaluates the use of PET/CT in pediatric PTLD at our institution. To assess the role of PET/CT in pediatric PTLD, we reviewed the pediatric patients with PTLD who had undergone PET/CT at our institution between 2000 and 2016. Nine patients were identified. Six had PET/CT at diagnosis. All lesions seen on CT were identified with PET/CT. Fourteen PET/CTs were done during treatment. Eight PET/CTs were negative, including three where CT showed areas of uncertain significance. In these cases, PET/CT helped us to stop treatment and the patients remain in remission after a long follow-up (mean 74.3 months; range 12.4-180.9 months). PET/CT revealed additional disease in two cases, therefore treatment was intensified. Six biopsies and close follow-up was done to confirm PET/CT results. In one case, PET/CT did not identify central nervous system involvement demonstrated on magnetic resonance imaging. PET/CT may have an important role in the staging and follow-up of pediatric PTLD. In our cohort, PET/CT was helpful in staging and assessing treatment response and in clarifying equivocal findings on other imaging modalities. © 2017 Wiley Periodicals, Inc.
Salem, A; Salem, A F; Al-Ibraheem, A; Lataifeh, I; Almousa, A; Jaradat, I
2011-01-01
In recent years, the role of positron emission tomography (PET) in the staging and management of gynecological cancers has been increasing. The aim of this study was to systematically review the role of PET in radiotherapy planning and brachytherapy treatment optimization in patients with cervical cancer. Systematic literature review. Systematic review of relevant literature addressing the utilization of PET and/or PET-computed tomography (CT) in external-beam radiotherapy planning and brachytherapy treatment optimization. We performed an extensive PubMed database search on 20 April 2011. Nineteen studies, including 759 patients, formed the basis of this systematic review. PET/ PET-CT is the most sensitive imaging modality for detecting nodal metastases in patients with cervical cancer and has been shown to impact external-beam radiotherapy planning by modifying the treatment field and customizing the radiation dose. This particularly applies to detection of previously uncovered para-aortic and inguinal nodal metastases. Furthermore, PET/ PET-CT guided intensity-modulated radiation therapy (IMRT) allows delivery of higher doses of radiation to the primary tumor, if brachytherapy is unsuitable, and to grossly involved nodal disease while minimizing treatment-related toxicity. PET/ PET-CT based brachytherapy optimization allows improved tumor-volume dose distribution and detailed 3D dosimetric evaluation of risk organs. Sequential PET/ PET-CT imaging performed during the course of brachytherapy form the basis of âadaptiveâ brachytherapy in cervical cancer. This review demonstrates the effectiveness of pretreatment PET/ PET-CT in cervical cancer patients treated by radiotherapy. Further prospective studies are required to define the group of patients who would benefit the most from this procedure.
Fantoni, Enrico R.; Chalkidou, Anastasia; O’ Brien, John T.; Farrar, Gill; Hammers, Alexander
2018-01-01
Background: Amyloid PET (aPET) imaging could improve patient outcomes in clinical practice, but the extent of impact needs quantification. Objective: To provide an aggregated quantitative analysis of the value added by aPET in cognitively impaired subjects. Methods: Systematic literature searches were performed in Embase and Medline until January 2017. 1,531 cases over 12 studies were included (1,142 cases over seven studies in the primary analysis where aPET was the key biomarker; the remaining cases included as defined groups in the secondary analysis). Data was abstracted by consensus among two observers and assessed for bias. Clinical utility was measured by diagnostic change, diagnostic confidence, and patient management before and after aPET. Three groups were further analyzed: control patients for whom feedback of aPET scan results was delayed; aPET Appropriate Use Criteria (AUC+) cases; and patients undergoing additional FDG/CSF testing. Results: For 1,142 cases with only aPET, 31.3% of diagnoses were revised, whereas 3.2% of diagnoses changed in the delayed aPET control group (p < 0.0001). Increased diagnostic confidence following aPET was found for 62.1% of 870 patients. Management changes with aPET were found in 72.2% of 740 cases and in 55.5% of 299 cases in the control group (p < 0.0001). The diagnostic value of aPET in AUC+ patients or when FDG/CSF were additionally available did not substantially differ from the value of aPET alone in the wider population. Conclusions: Amyloid PET contributed to diagnostic revision in almost a third of cases and demonstrated value in increasing diagnostic confidence and refining management plans. PMID:29689725
PET/MR Imaging in Gynecologic Oncology.
Ohliger, Michael A; Hope, Thomas A; Chapman, Jocelyn S; Chen, Lee-May; Behr, Spencer C; Poder, Liina
2017-08-01
MR imaging and PET using 2-Deoxy-2-[ 18 F]fluoroglucose (FDG) are both useful in the evaluation of gynecologic malignancies. MR imaging is superior for local staging of disease whereas fludeoxyglucose FDG PET is superior for detecting distant metastases. Integrated PET/MR imaging scanners have great promise for gynecologic malignancies by combining the advantages of each modality into a single scan. This article reviews the technology behind PET/MR imaging acquisitions and technical challenges relevant to imaging the pelvis. A dedicated PET/MR imaging protocol; the roles of PET and MR imaging in cervical, endometrial, and ovarian cancers; and future directions for PET/MR imaging are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.
Albert, Nathalie L.; Weller, Michael; Suchorska, Bogdana; Galldiks, Norbert; Soffietti, Riccardo; Kim, Michelle M.; la Fougère, Christian; Pope, Whitney; Law, Ian; Arbizu, Javier; Chamberlain, Marc C.; Vogelbaum, Michael; Ellingson, Ben M.
2016-01-01
This guideline provides recommendations for the use of PET imaging in gliomas. The review examines established clinical benefit in glioma patients of PET using glucose (18F-FDG) and amino acid tracers (11C-MET, 18F-FET, and 18F-FDOPA). An increasing number of studies have been published on PET imaging in the setting of diagnosis, biopsy, and resection as well radiotherapy planning, treatment monitoring, and response assessment. Recommendations are based on evidence generated from studies which validated PET findings by histology or clinical course. This guideline emphasizes the clinical value of PET imaging with superiority of amino acid PET over glucose PET and provides a framework for the use of PET to assist in the management of patients with gliomas. PMID:27106405
MO-FG-207-03: Maximizing the Utility of Integrated PET/MRI in Clinical Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Behr, S.
2015-06-15
The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applicationsmore » that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.« less
MO-FG-207-00: Technological Advances in PET/MR Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-06-15
The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applicationsmore » that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.« less
Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT
Queiroz, Marcelo A.; Delso, Gaspar; Wollenweber, Scott; Deller, Timothy; Zeimpekis, Konstantinos; Huellner, Martin; de Galiza Barbosa, Felipe; von Schulthess, Gustav; Veit-Haibach, Patrick
2015-01-01
Purpose To evaluate the possible activity reduction in FDG-imaging in a Time-of-Flight (TOF) PET/MR, based on cross-evaluation of patient-based NECR (noise equivalent count rate) measurements in PET/CT, cross referencing with phantom-based NECR curves as well as initial evaluation of TOF-PET/MR with reduced activity. Materials and Methods A total of 75 consecutive patients were evaluated in this study. PET/CT imaging was performed on a PET/CT (time-of-flight (TOF) Discovery D 690 PET/CT). Initial PET/MR imaging was performed on a newly available simultaneous TOF-PET/MR (Signa PET/MR). An optimal NECR for diagnostic purposes was defined in clinical patients (NECRP) in PET/CT. Subsequent optimal activity concentration at the acquisition time ([A]0) and target NECR (NECRT) were obtained. These data were used to predict the theoretical FDG activity requirement of the new TOF-PET/MR system. Twenty-five initial patients were acquired with (retrospectively reconstructed) different imaging times equivalent for different activities on the simultaneous PET/MR for the evaluation of clinically realistic FDG-activities. Results The obtained values for NECRP, [A]0 and NECRT were 114.6 (± 14.2) kcps (Kilocounts per second), 4.0 (± 0.7) kBq/mL and 45 kcps, respectively. Evaluating the NECRT together with the phantom curve of the TOF-PET/MR device, the theoretical optimal activity concentration was found to be approximately 1.3 kBq/mL, which represents 35% of the activity concentration required by the TOF-PET/CT. Initial evaluation on patients in the simultaneous TOF-PET/MR shows clinically realistic activities of 1.8 kBq/mL, which represent 44% of the required activity. Conclusion The new TOF-PET/MR device requires significantly less activity to generate PET-images with good-to-excellent image quality, due to improvements in detector geometry and detector technologies. The theoretically achievable dose reduction accounts for up to 65% but cannot be fully translated into clinical routine based on the coils within the FOV and MR-sequences applied at the same time. The clinically realistic reduction in activity is slightly more than 50%. Further studies in a larger number of patients are needed to confirm our findings. PMID:26147919
Chan, Joachim; Carver, Antony; Brunt, John N H; Vinjamuri, Sobhan; Syndikus, Isabel
2017-03-01
Prostate dose painting radiotherapy requires the accurate identification of dominant intraprostatic lesions (DILs) to be used as boost volumes; these can be identified on multiparametric MRI (mpMRI) or choline positron emission tomography (PET)/CT. Planning scans are usually performed after 2-3 months of androgen deprivation therapy (ADT). We examine the effect of ADT on choline tracer uptake and boost volumes identified on choline PET/CT. Fluoroethylcholine ( 18 F choline) PET/CT was performed for dose painting radiotherapy planning in patients with intermediate- to high-risk prostate cancer. Initially, they were performed at planning. Owing to low visual tracer uptake, PET/CT for subsequent patients was performed at staging. We compared these two approaches on intraprostatic lesions obtained on PET using both visual and automatic threshold methods [prostate maximum standardized uptake value (SUV max ) 60%] when compared with mpMRI. PET/CT was performed during ADT in 11 patients (median duration of 85 days) and before ADT in 29 patients. ADT significantly reduced overall prostate volume by 17%. During ADT, prostate SUV max was lower although it did not reach statistical significance (4.2 vs 6.6, p = 0.06); three patients had no visually identifiable PET DIL; and visually defined PET DILs were significantly smaller than corresponding mpMRI DILs (p = 0.03). However, all patients scanned before ADT had at least one visually identifiable PET DIL, with no significant size difference between MRI and visually defined PET DILs. In both groups, threshold PET produced larger DILs than visual PET. Both PET methods have moderate sensitivity (0.50-0.68) and high specificity (0.85-0.98) for identifying MRI-defined disease. For visual contouring of boost volumes in prostate dose painting radiotherapy, 18 F choline PET/CT should be performed before ADT. For threshold contouring of boost volumes using our PET/CT scanning protocol, threshold levels of above 60% prostate SUV max may be more suitable. Additional use of PET with MRI for radiotherapy planning can significantly change the overall boost volumes compared with using MRI alone. Advances in knowledge: For prostate dose painting radiotherapy, the additional use of 18 F choline PET with MRI can significantly change the overall boost volumes, and PET should be performed before hormone therapy, especially if boost volumes are visually identified.
SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Y; Bowsher, J; Yan, S
2014-06-01
Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medicalmore » Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.« less
Advances in time-of-flight PET
Surti, Suleman; Karp, Joel S.
2016-01-01
This paper provides a review and an update on time-of-flight PET imaging with a focus on PET instrumentation, ranging from hardware design to software algorithms. We first present a short introduction to PET, followed by a description of TOF PET imaging and its history from the early days. Next, we introduce the current state-of-art in TOF PET technology and briefly summarize the benefits of TOF PET imaging. This is followed by a discussion of the various technological advancements in hardware (scintillators, photo-sensors, electronics) and software (image reconstruction) that have led to the current widespread use of TOF PET technology, and future developments that have the potential for further improvements in the TOF imaging performance. We conclude with a discussion of some new research areas that have opened up in PET imaging as a result of having good system timing resolution, ranging from new algorithms for attenuation correction, through efficient system calibration techniques, to potential for new PET system designs. PMID:26778577
How PET/MR Can Add Value For Children With Cancer.
Daldrup-Link, Heike
2017-03-01
To review how PET/MR technology could add value for pediatric cancer patients. Since many primary tumors in children are evaluated with MRI and metastases are detected with PET/CT, integrated PET/MR can be a time-efficient and convenient solution for pediatric cancer staging. 18 F-FDG PET/MR can assess primary tumors and the whole body in one imaging session, avoid repetitive anesthesia and reduce radiation exposure compared to 18 F-FDG PET/CT. This article lists 10 action points, which might improve the clinical value of PET/MR for children with cancer. However, even if PET/MR proves valuable, it cannot enter mainstream applications if it is not accessible to the majority of pediatric cancer patients. Therefore, innovations are needed to make PET/MR scanners affordable and increase patient throughput. PET/MR offers opportunities for more efficient, accurate and safe diagnoses of pediatric cancer patients. The impact on patient management and outcomes has to be substantiated by large-scale prospective clinical trials.
Technical aspects of cardiac PET/MRI.
Masuda, Atsuro; Nemoto, Ayaka; Takeishi, Yasuchika
2018-06-01
PET/MRI is a novel modality that enables to combine PET and MR images, and has significant potential to evaluate various cardiac diseases through the combination of PET molecular imaging and MRI functional imaging. Precise management of technical issues, however, is necessary for cardiac PET/MRI. This article describes several technical points, including patient preparation, MR attenuation correction, parallel acquisition of PET with MRI, clinical aspects, and image quality control.
Disselhorst, Jonathan A; Bezrukov, Ilja; Kolb, Armin; Parl, Christoph; Pichler, Bernd J
2014-06-01
Hybrid PET/MR systems have rapidly progressed from the prototype stage to systems that are increasingly being used in the clinics. This review provides an overview of developments in hybrid PET/MR systems and summarizes the current state of the art in PET/MR instrumentation, correction techniques, and data analysis. The strong magnetic field requires considerable changes in the manner by which PET images are acquired and has led, among others, to the development of new PET detectors, such as silicon photomultipliers. During more than a decade of active PET/MR development, several system designs have been described. The technical background of combined PET/MR systems is explained and related challenges are discussed. The necessity for PET attenuation correction required new methods based on MR data. Therefore, an overview of recent developments in this field is provided. Furthermore, MR-based motion correction techniques for PET are discussed, as integrated PET/MR systems provide a platform for measuring motion with high temporal resolution without additional instrumentation. The MR component in PET/MR systems can provide functional information about disease processes or brain function alongside anatomic images. Against this background, we point out new opportunities for data analysis in this new field of multimodal molecular imaging. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Durable grafting of silkworm pupa protein onto the surface of polyethylene terephthalate fibers.
Zhou, Jianfeng; Zheng, Dandan; Zhang, Fengxiu; Zhang, Guangxian
2016-12-01
In this paper, reactive -NH2 groups (8.36×10(-6)mol/g fabric) were introduced to the surface of polyethylene terephthalate (PET) fabrics by a nitration and reduction method, and epoxy groups were introduced to silkworm pupa protein (SPP) by reaction with epoxy chloropropane. PET-SPP composite fabrics were then prepared by reaction of these two precursors. The results showed that the SPP was firmly grafted onto the PET fabric surface and that the hydrophilicity of the fabric was markedly improved by the grafting of SPP. SEM images revealed a layer of substance covering the surface of the PET fibers, and XPS investigation showed that the nitrogen content of the PET-SPP fabric was higher than that of the original PET fabric (2.32% vs 0%). ATR-FTIR adsorption bands at 1653 and 1543cm(-1) suggested the successful grafting of SPP onto the PET fabric surface. The DSC and TG of the PET fibers demonstrated that the thermal stability of the original PET fibers was maintained well by the SPP-grafted PET fibers. The breaking strength, bending rigidity, air permeability, and crease recovery angle of the original PET fabric were also retained by the SPP-grafted PET fabric. Copyright © 2016 Elsevier B.V. All rights reserved.
Han, Zhenzhen; Wang, Yao; Wang, Jiuxing; Wang, Shichao; Zhuang, Hongwei; Liu, Jixian; Huang, Linjun; Wang, Yanxin; Wang, Wei; Belfiore, Laurence A.; Tang, Jianguo
2018-01-01
In this research contribution, the primary objective was to enhance the crystallization behavior of poly(ethylene terephthalate) (PET). To accomplish this tack, three kinds of new nucleating agents SiO2-diethylene glycol-LMPET (PET-3), SiO2-triethylene glycol–LMPET(PET-4) and SiO2-tetraethylene glycol-LMPET (PET-5) nucleating agents were prepared via grafting different oligomers (diethylene glycol; triethylene glycol and tetraethylene glycol) to the surface of nano-SiO2 and then linking to the low molecular weight poly(ethylene terephthalate) (LMPET). These nano-particle nucleating agents facilitated the crystallization of PET. Differential scanning calorimetry (DSC) studies of the composites that pure PET blended with PET-3, PET-4 and PET-5 indicated that the longer ethoxy segment in the nucleating agents exhibited (i) higher degrees of crystallinity; (ii) faster rates of crystallization; and (iii) higher crystallization temperatures. The Jeziorny method was employed to analyze the non-isothermal crystallization kinetics of the composites. These works demonstrated that the PET-3, PET-4 and PET-5 were attractive nucleating agents for poly(ethylene terephthalate), and the longer the chain length of the ethoxy segment in the nucleating agents, the more efficient the nucleation effect. PMID:29641456
PSMA PET in prostate cancer – a step towards personalized medicine
Bouchelouche, Kirsten; Choyke, Peter L.
2017-01-01
Purpose of review Increasing attention is being given to personalized medicine in oncology, where therapies are tailored to the particular characteristics of the individual cancer patient. In recent years, there has been greater focus on PSMA in prostate cancer (PCa) as a target for imaging and therapy with radionuclides. This review highlights the recent advancements in PSMA PET in PCa during the past year. Recent findings Several reports on PSMA PET/CT in PCa patients are demonstrating promising results, especially for detection of biochemical recurrence. 18F-PSMA PET/CT may be superior to 68Ga-PSMA PET/CT. The detection rate of PSMA PET is influenced by PSA level. PSMA PET/CT may have a higher detection rate than choline PET/CT. Only a few reports have been published on PSMA PET/MRI, and this modality remains to be elucidated further. Conclusion Molecular imaging with PSMA PET is paving the way for personalized medicine in PCa. However, large prospective clinical studies are needed to further evaluate the role of PSMA PET/CT and PET/MRI in the clinical workflow of PCa. PSMA is an excellent target for imaging and therapy with radionuclides, and the “image and treat” strategy has the potential to become a milestone in the management of PCa patients. PMID:26967720
Pet-keeping in early childhood and airway, nose and skin symptoms later in life.
Bornehag, C G; Sundell, J; Hagerhed, L; Janson, S
2003-09-01
It is discussed whether exposure to pets during childhood is a risk or a protective factor for sensitization and allergic symptoms. The aim of this study was to investigate the association between pet-keeping at time of birth and allergic symptoms in airways, nose and skin among young children in Sweden. A questionnaire was sent to the parents of 14 077 children (1-6 years), the focus being on allergic symptoms, home environment and other background factors including pet-keeping and avoidance behaviour. The response rate was 79%. Almost one-tenth of the population had got rid of pets because of allergy in the family, and 27.3% reported "avoidance" behaviour towards pets. In a cross-sectional analysis current pet-keeping was "protective", but this may be due to the fact that people avoid exposing their child to something that they believe is a risk factor for allergies. Pet-keeping at the time of birth was associated with "wheezing", "asthma" and "rhinitis on pet-exposure" later in life for children from families with an "avoidance" behaviour, and was not "protective" for other children. There was also an indication of a dose-response relationship between the number of types of furred pets at time of birth and later symptoms in analyses adjusted for avoidance behaviour or current pet-keeping. The distribution of pet-keeping in the population is largely explained by avoidance behaviour, meaning that those who have pets mainly are those who can stand them, indicating a "healthy pet-keeping effect".
Rojas-Anaya, Hector; Skogen, Karoline; Miles, Kenneth Alan
2012-06-01
To identify factors that influence the use of PET in phase III oncology trials in the UK by evaluating stakeholder perspectives. A wide range of UK PET research stakeholders with a potential interest in the use of PET in phase III trials were identified and invited to participate. These UK PET research stakeholders were consulted using a semistructured questionnaire on their personal experience with and involvement in PET research, the role of PET in phase III oncology clinical trials and on the promotion of UK PET research and unmet clinical needs in oncology. Responses were analysed quantitatively and by qualitative content analysis of free-text responses. A total of 118 responses were received from a wide range of stakeholders representing several professional groups and working environments. Of these respondents, 49 (42%) were using PET in their research. There was the general perception that using PET in clinical research is beneficial in oncology. The two major barriers identified were poor availability of PET and perceived difficulties in funding of excess treatment costs (75% of respondents). Other factors included limited coverage of PET in training, uncertainty about developing imaging protocols or the status of tracers other than 18F-fluorodeoxyglucose, and low awareness of the role of PET in patient selection for therapeutic trials. Patient concerns about radiation were not perceived as a research barrier. Interventions that improve the availability and funding pathways for PET research scans and that increase researcher awareness could help promote the use of PET for phase III oncology trials in the UK.
Gupta, Nidhi; Yadav, Tushar
2018-04-16
To evaluate the parents' acceptance to therapy pets, child's most favoured pet, child's choice of soft toy as compared to live pet, and child's preference of his own pet versus therapy pet. Sixty-two children of age groups 3-6 year, 6-9 year, and 9-12 year were selected. The data from completed questionnaires were statistically analysed and subjected to z test, Chi-squared test with P value<0.05 considered as significant. The consent to the presence of pet was given by 41.47% parents of 9- to 12-year-old children, 34.15% parents of 6- to 9-year-old children and 24.39% parents of 3- to 6-year-old children. Children who chose dog as their preferred pet were 56.7%; those who chose cat as their preferred pet were 44%. A majority of 3-to 6-year-olds (63.15%) had dog & cat as their choice, while 6- to 9-year-olds (65.21%) & 9- to 12-year-olds (40%) preferred dogs over all others. Dog was the favourite pet of 46.8% children. More percentage of children wanted pet provided by clinic. Animal-Assisted Therapy (AAT) can prove to be a good behaviour management technique if more parents are made aware and informed about AAT; dog is one of the highly recommended pets for AAT, and therapy pet should be preferred over home pet. © 2018 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Garcia-Vicente, Ana María; Molina, David; Pérez-Beteta, Julián; Amo-Salas, Mariano; Martínez-González, Alicia; Bueno, Gloria; Tello-Galán, María Jesús; Soriano-Castrejón, Ángel
2017-12-01
To study the influence of dual time point 18F-FDG PET/CT in textural features and SUV-based variables and their relation among them. Fifty-six patients with locally advanced breast cancer (LABC) were prospectively included. All of them underwent a standard 18F-FDG PET/CT (PET-1) and a delayed acquisition (PET-2). After segmentation, SUV variables (SUVmax, SUVmean, and SUVpeak), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were obtained. Eighteen three-dimensional (3D) textural measures were computed including: run-length matrices (RLM) features, co-occurrence matrices (CM) features, and energies. Differences between all PET-derived variables obtained in PET-1 and PET-2 were studied. Significant differences were found between the SUV-based parameters and MTV obtained in the dual time point PET/CT, with higher values of SUV-based variables and lower MTV in the PET-2 with respect to the PET-1. In relation with the textural parameters obtained in dual time point acquisition, significant differences were found for the short run emphasis, low gray-level run emphasis, short run high gray-level emphasis, run percentage, long run emphasis, gray-level non-uniformity, homogeneity, and dissimilarity. Textural variables showed relations with MTV and TLG. Significant differences of textural features were found in dual time point 18F-FDG PET/CT. Thus, a dynamic behavior of metabolic characteristics should be expected, with higher heterogeneity in delayed PET acquisition compared with the standard PET. A greater heterogeneity was found in bigger tumors.
Preparation of alpha-emitting nuclides by electrodeposition
NASA Astrophysics Data System (ADS)
Lee, M. H.; Lee, C. W.
2000-06-01
A method is described for electrodepositing the alpha-emitting nuclides. To determine the optimum conditions for plating plutonium, the effects of electrolyte concentration, chelating reagent, current, pH of electrolyte and the time of plating on the electrodeposition were investigated on the base of the ammonium oxalate-ammonium sulfate electrolyte containing diethyl triamino pentaacetic acid. An optimized electrodeposition procedure for the determination of plutonium was validated by application to environmental samples. The chemical yield of the optimized method of electrodeposition step in the environmental sample was a little higher than that of Talvitie's method. The developed electrodeposition procedure in this study was applied to determine the radionuclides such as thorium, uranium and americium that the electrodeposition yields were a little higher than those of the conventional method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Jun
The experimental nuclear structure data and decay data are evaluated for the known nuclides of mass 40 (Mg, Al, Si, P, S, Cl, Ar, K, Ca, Sc, Ti). Detailed evaluated nuclear structure information is presented with the best values recommended for level energies, half-lives, γ-ray energies and intensities, decay properties (energies, intensities and placement of radiations), and other spectroscopic data. The {sup 40}Ca and {sup 40}K nuclides remain as the most extensively studied from many different reactions and decays; no excited states are known in {sup 40}Mg, {sup 40}Al, {sup 40}P and {sup 40}Ti. This work supersedes the earlier fullmore » evaluation of A=40 by J. Cameron and B. Singh (2004Ca38).« less
Cosmogenic nuclides in football-sized rocks.
NASA Technical Reports Server (NTRS)
Wahlen, M.; Honda, M.; Imamura, M.; Fruchter, J. S.; Finkel, R. C.; Kohl, C. P.; Arnold, J. R.; Reedy, R. C.
1972-01-01
The activity of long- and short-lived isotopes in a series of samples from a vertical column through the center of rock 14321 was measured. Rock 14321 is a 9 kg fragmental rock whose orientation was photographically documented on the lunar surface. Also investigated was a sample from the lower portion of rock 14310, where, in order to study target effects, two different density fractions (mineral separates) were analyzed. A few nuclides in a sample from the comprehensive fines 14259 were measured. This material has been collected largely from the top centimeter of the lunar soil. The study of the deep samples of 14321 and 14310 provided values for the activity of isotopes at points where only effects produced by galactic cosmic rays are significant.
Energy Production and Transmutation of Nuclear Waste by Accelerator Driven Systems
NASA Astrophysics Data System (ADS)
Zhivkov, P. K.
2018-05-01
There is a significant amount of highly radiotoxic long-life nuclear waste (NW) produced by NPP (Nuclear Power Plants). Transmutation is a process which transforms NW into less radiotoxic nuclides with a shorter period of half-life by spallation neutrons or radiative capture of neutrons produced by ADS (Accelerator Driven System). In the processes of transmutation new radioactive nuclides are produced. ADS is big energy consumer equipment. It is a method for production of a high-flux and high-energy neutron field. All these processes occur in ADS simultaneously. ADS is able to transmute actinides and produce energy simultaneously. The article considers the energy production problems in ADS. Several ideas are developed regarding the solution of the global energy supply.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, Herman
2016-09-01
Allowed transition energies and eigenstate expansions have been calculated and tabulated in numerical form as functions of the electric field gradient asymmetry parameter for the zero field Hamiltonian of quadrupolar nuclides with I = 3/2, 5/2, 7/2, and 9/2. These results may be used to interpret nuclear quadrupole resonance (NQR) spectra and extract accurate values of the electric field gradient tensors. Applications of NQR methods to studies of electronic structure in heavy element systems are proposed. This material is based upon work supported by the U.S. Department of Energy Office of Science, Office of Basic Energy Sciences, Heavy Element Chemistrymore » program.« less
An update on 'dose calibrator' settings for nuclides used in nuclear medicine.
Bergeron, Denis E; Cessna, Jeffrey T
2018-06-01
Most clinical measurements of radioactivity, whether for therapeutic or imaging nuclides, rely on commercial re-entrant ionization chambers ('dose calibrators'). The National Institute of Standards and Technology (NIST) maintains a battery of representative calibrators and works to link calibration settings ('dial settings') to primary radioactivity standards. Here, we provide a summary of NIST-determined dial settings for 22 radionuclides. We collected previously published dial settings and determined some new ones using either the calibration curve method or the dialing-in approach. The dial settings with their uncertainties are collected in a comprehensive table. In general, current manufacturer-provided calibration settings give activities that agree with National Institute of Standards and Technology standards to within a few percent.
Transmutation of 129I and 237Np using spallation neutrons produced by 1.5, 3.7 and 7.4 GeV protons
NASA Astrophysics Data System (ADS)
Wan, J.-S.; Schmidt, Th.; Langrock, E.-J.; Vater, P.; Brandt, R.; Adam, J.; Bradnova, V.; Bamblevski, V. P.; Gelovani, L.; Gridnev, T. D.; Kalinnikov, V. G.; Krivopustov, M. I.; Kulakov, B. A.; Sosnin, A. N.; Perelygin, V. P.; Pronskikh, V. S.; Stegailov, V. I.; Tsoupko-Sitnikov, V. M.; Modolo, G.; Odoj, R.; Phlippen, P.-W.; Zamani-Valassiadou, M.; Adloff, J. C.; Debeauvais, M.; Hashemi-Nezhad, S. R.; Guo, S.-L.; Li, L.; Wang, Y.-L.; Dwivedi, K. K.; Zhuk, I. V.; Boulyga, S. F.; Lomonossova, E. M.; Kievitskaja, A. F.; Rakhno, I. L.; Chigrinov, S. E.; Wilson, W. B.
2001-05-01
Small samples of 129I and 237Np, two long-lived radwaste nuclides, were exposed to spallation neutron fluences from relatively small metal targets of lead and uranium, that were surrounded with a 6 cm thick paraffin moderator, and irradiated with 1.5, 3.7 and 7.4 GeV protons. The (n,γ) transmutation rates were determined for these nuclides. Conventional radiochemical La- and U-sensors and a variety of solid-state nuclear track detectors were irradiated simultaneously with secondary neutrons. Compared with results from calculations with well-known cascade codes (LAHET from Los Alamos and DCM/CEM from Dubna), the observed secondary neutron fluences are larger.
Injuries caused by pets in Asian urban households: a cross-sectional telephone survey.
Chan, Emily Y Y; Gao, Yang; Li, Liping; Lee, Po Yi
2017-01-20
Little is known about pet-related injuries in Asian populations. This study primarily aimed to investigate the incidence rate of pet-related household injuries in Hong Kong, an urban Chinese setting. Cantonese-speaking non-institutionalised population of all ages in Hong Kong accessible by telephone land-line. A total of 43 542 telephone numbers were dialled and 6570 residents successfully completed the interviews. Data of pet-related household injuries in the previous 12 months, pet ownership and socio-demographic characteristics were collected with a questionnaire. Direct standardisation of the incidence rates of pet-related household injuries by gender and age to the 2009 Hong Kong Population Census was estimated. Univariate and multivariate analyses were performed to estimate risks of socio-demographic factors and pet ownership for the injury. A total of 84 participants experienced pet-related household injuries in the past 12 months, with an overall person-based incidence rate of 1.28%. The majority of the victims were injured once (69.6%). Cats (51.6%) were the most common pets involved. Pet owners were at an extremely higher risk after controlling for other factors (adjusted OR: 52.0, 95% CI 22.1 to 98.7). Females, the unmarried, those with higher monthly household income and those living in lower-density housing were more likely to be injured by pets. We project a pet-related household injury incidence rate of 1.24% in the general Hong Kong population, with 86 334 residents sustaining pet-related injuries every year. Pet ownership puts people at extremely high risk, especially the unmarried. Further studies should focus on educating pet owners to reduce pet-related injuries in urban Greater China. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Bluemel, Christina; Krebs, Markus; Polat, Bülent; Linke, Fränze; Eiber, Matthias; Samnick, Samuel; Lapa, Constantin; Lassmann, Michael; Riedmiller, Hubertus; Czernin, Johannes; Rubello, Domenico; Bley, Thorsten; Kropf, Saskia; Wester, Hans-Juergen; Buck, Andreas K; Herrmann, Ken
2016-07-01
Investigating the value of Ga-PSMA-PET/CT in biochemically recurring prostate cancer patients with negative F-choline-PET/CT. One hundred thirty-nine consecutive patients with biochemical recurrence after curative (surgery and/or radiotherapy) therapy were offered participation in this sequential clinical imaging approach. Patients first underwent an F-choline-PET/CT. If negative, an additional Ga-PSMA-PET/CT was offered. One hundred twenty-five of 139 eligible patients were included in the study; 32 patients underwent additional Ga-PSMA-PET/CT. Patients with equivocal findings (n = 5) on F-choline-PET/CT and those who declined the additional Ga-PSMA-PET/CT (n = 9) were excluded. Images were analyzed visually for the presence of suspicious lesions. Findings on PET/CT were correlated with PSA level, PSA doubling time (dt), and PSA velocity (vel). The overall detection rates were 85.6% (107/125) for the sequential imaging approach and 74.4% (93/125) for F-choline-PET/CT alone. Ga-PSMA-PET/CT detected sites of recurrence in 43.8% (14/32) of the choline-negative patients. Detection rates of the sequential imaging approach and F-choline-PET/CT alone increased with higher serum PSA levels and PSA vel. Subgroup analysis of Ga-PSMA-PET/CT in F-choline negative patients revealed detection rates of 28.6%, 45.5%, and 71.4% for PSA levels of 0.2 or greater to less than 1 ng/mL, 1 to 2 ng/mL, and greater than 2 ng/mL, respectively. The sequential imaging approach designed to limit Ga-PSMA imaging to patients with negative choline scans resulted in high detection rates. Ga-PSMA-PET/CT identified sites of recurrent disease in 43.8% of the patients with negative F-choline PET/CT scans.
Bluemel, Christina; Krebs, Markus; Polat, Bülent; Linke, Fränze; Eiber, Matthias; Samnick, Samuel; Lapa, Constantin; Lassmann, Michael; Riedmiller, Hubertus; Czernin, Johannes; Rubello, Domenico; Bley, Thorsten; Kropf, Saskia; Wester, Hans-Juergen; Buck, Andreas K.; Herrmann, Ken
2016-01-01
Purpose Investigating the value of 68Ga-PSMA-PET/CT in biochemically recurring prostate cancer patients with negative 18F-choline-PET/CT. Patients and Methods One hundred thirty-nine consecutive patients with biochemical recurrence after curative (surgery and/or radiotherapy) therapy were offered participation in this sequential clinical imaging approach. Patients first underwent an 18F-choline-PET/CT. If negative, an additional 68Ga-PSMA-PET/CTwas offered. One hundred twenty-five of 139 eligible patients were included in the study; 32 patients underwent additional 68Ga-PSMA-PET/CT. Patients with equivocal findings (n = 5) on 18F-choline-PET/CT and those who declined the additional 68Ga-PSMA-PET/CT (n = 9) were excluded. Images were analyzed visually for the presence of suspicious lesions. Findings on PET/CT were correlated with PSA level, PSA doubling time (dt), and PSA velocity (vel). Results The overall detection rates were 85.6% (107/125) for the sequential imaging approach and 74.4% (93/125) for 18F-choline-PET/CT alone. 68Ga-PSMA-PET/CT detected sites of recurrence in 43.8% (14/32) of the choline-negative patients. Detection rates of the sequential imaging approach and 18F-choline-PET/CT alone increased with higher serum PSA levels and PSA vel. Subgroup analysis of 68Ga-PSMA-PET/CT in 18F-choline negative patients revealed detection rates of 28.6%, 45.5%, and 71.4% for PSA levels of 0.2 or greater to less than 1 ng/mL, 1 to 2 ng/mL, and greater than 2 ng/mL, respectively. Conclusions The sequential imaging approach designed to limit 68Ga-PSMA imaging to patients with negative choline scans resulted in high detection rates. 68Ga-PSMA-PET/CT identified sites of recurrent disease in 43.8% of the patients with negative 18F-choline PET/CT scans. PMID:26975008
Simultaneous PET/MR imaging with a radio frequency-penetrable PET insert
Grant, Alexander M.; Lee, Brian J.; Chang, Chen-Ming; Levin, Craig S.
2017-01-01
Purpose A brain sized radio-frequency (RF)-penetrable PET insert has been designed for simultaneous operation with MRI systems. This system takes advantage of electro-optical coupling and battery power to electrically float the PET insert relative to the MRI ground, permitting RF signals to be transmitted through small gaps between the modules that form the PET ring. This design facilitates the use of the built-in body coil for RF transmission, and thus could be inserted into any existing MR site wishing to achieve simultaneous PET/MR imaging. The PET detectors employ non-magnetic silicon photomultipliers in conjunction with a compressed sensing signal multiplexing scheme, and optical fibers to transmit analog PET detector signals out of the MRI room for decoding, processing, and image reconstruction. Methods The PET insert was first constructed and tested in a laboratory benchtop setting, where tomographic images of a custom resolution phantom were successfully acquired. The PET insert was then placed within a 3T body MRI system, and tomographic resolution/contrast phantom images were acquired both with only the B0 field present, and under continuous pulsing from different MR imaging sequences. Results The resulting PET images have comparable contrast-to-noise ratios (CNR) under all MR pulsing conditions: the maximum percent CNR relative difference for each rod type among all four PET images acquired in the MRI system has a mean of 14.0±7.7%. MR images were successfully acquired through the RF-penetrable PET shielding using only the built-in MR body coil, suggesting that simultaneous imaging is possible without significant mutual interference. Conclusions These results show promise for this technology as an alternative to costly integrated PET/MR scanners; a PET insert that is compatible with any existing clinical MRI system could greatly increase the availability, accessibility, and dissemination of PET/MR. PMID:28102949
Zhu, W; Xing, L; Yue, J; Sun, X; Sun, X; Zhao, H; Yu, J
2012-09-01
The objective of this study was to comprehensively review the evidence for use of pre-treatment, post-treatment and changes in tumour glucose uptake that were assessed by 18-fludeoxyglucose ((18)F-FDG) positron emission tomography (PET) early, during or immediately after neoadjuvant chemotherapy/chemoradiation to predict prognosis of localised oesophagogastric junction (AEG) cancer. We searched for articles published in English; limited to AEG; (18)F-FDG uptake on PET performed on a dedicated device; dealt with the impact of standard uptake value (SUV) on survival. We extracted an estimate of the log hazard ratios (HRs) and their variances and performed meta-analysis. 798 patients with AEG were included. And the scan time for (18)F-FDG-PET was as follows: prior to therapy (PET1, n=646), exactly 2 weeks after initiation of neoadjuvant therapy (PET2, n=245), and pre-operatively (PET3, n=278). In the two meta-analyses for overall survival, including the studies that dealt with reduction of tumour maximum SUV (SUV(max)) (from PET1 to PET2/PET3 and from PET1 to PET2), the results were similar, with the overall HR for non-responders being 1.83 [95% confidence interval (CI), 1.41-2.36] and 2.62 (95% CI, 1.61-4.26), respectively; as for disease-free survival, the combined HR was 2.92 (95% CI, 2.08-4.10) and 2.39 (95% CI, 1.57-3.64), respectively. The meta-analyses did not attribute significant prognostic values to SUV(max) before and during therapy in localised AEG. Relative changes in FDG-uptake of AEG are better prognosticators. Early metabolic changes from PET1 to PET2 may provide the same accuracy for prediction of treatment outcome as late changes from PET1 to PET3.
Eyeblink conditioning in unmedicated schizophrenia patients: a positron emission tomography study.
Parker, Krystal L; Andreasen, Nancy C; Liu, Dawei; Freeman, John H; O'Leary, Daniel S
2013-12-30
Previous studies suggest that patients with schizophrenia exhibit dysfunctions in a widely distributed circuit-the cortico-cerebellar-thalamic-cortical circuit, or CCTCC-and that this may explain the multiple cognitive deficits observed in the disorder. This study uses positron emission tomography (PET) with O(15) H₂O to measure regional cerebral blood flow (rCBF) in response to a classic test of cerebellar function, the associative learning that occurs during eyeblink conditioning, in a sample of 20 unmedicated schizophrenia patients and 20 closely matched healthy controls. The PET paradigm examined three phases of acquisition and extinction (early, middle and late). The patients displayed impaired behavioral performance during both acquisition and extinction. The imaging data indicate that, compared to the control subjects, the patients displayed decreases in rCBF in all three components of the CCTCC during both acquisition and extinction. Specifically, patients had less rCBF in the middle and medial frontal lobes, anterior cerebellar lobules I/V and VI, as well as the thalamus during acquisition and although similar areas were found in the frontal lobe, ipsilateral cerebellar lobule IX showed consistently less activity in patients during extinction. Thus this study provides additional support for the hypothesis that patients with schizophrenia have a cognitive dysmetria--an inability to smoothly coordinate many different types of mental activity--that affects even a very basic cognitive task that taps into associative learning. © 2013 Elsevier Ireland Ltd. All rights reserved.
Freitag, Martin T; Radtke, Jan P; Hadaschik, Boris A; Kopp-Schneider, A; Eder, Matthias; Kopka, Klaus; Haberkorn, Uwe; Roethke, Matthias; Schlemmer, Heinz-Peter; Afshar-Oromieh, Ali
2016-01-01
To evaluate the reproducibility of the combination of hybrid PET/MRI and the (68)Ga-PSMA-11 tracer in depicting lymph node (LN) and bone metastases of prostate cancer (PC) in comparison with that of PET/CT. A retrospective analysis of 26 patients who were subjected to (68)Ga-PSMA PET/CTlow-dose (1 h after injection) followed by PET/MRI (3 h after injection) was performed. MRI sequences included T1-w native, T1-w contrast-enhanced, T2-w fat-saturated and diffusion-weighted sequences (DWIb800). Discordant PET-positive and morphological findings were evaluated. Standardized uptake values (SUV) of PET-positive LNs and bone lesions were quantified and their morphological size and conspicuity determined. Comparing the PET components, the proportion of discordant PSMA-positive suspicious findings was very low (98.5 % of 64 LNs concordant, 100 % of 28 bone lesions concordant). Two PET-positive bone metastases could not be confirmed morphologically using CTlow-dose, but could be confirmed using MRI. In 12 of 20 patients, 47 PET-positive LNs (71.9 %) were smaller than 1 cm in short axis diameter. There were significant linear correlations between PET/MRI SUVs and PET/CT SUVs in the 64 LN metastases (p < 0.0001) and in the 28 osseous metastases (p < 0.0001) for SUVmean and SUVmax, respectively. The LN SUVs were significantly higher on PET/MRI than on PET/CT (p SUVmax < 0.0001; p SUVmean < 0.0001) but there was no significant difference between the bone lesion SUVs (p SUVmax = 0.495; p SUVmean = 0.381). Visibility of LNs was significantly higher on MRI using the T1-w contrast-enhanced fat-saturated sequence (p = 0.013), the T2-w fat-saturated sequence (p < 0.0001) and the DWI sequence (p < 0.0001) compared with CTlow-dose. For bone lesions, only the overall conspicuity was higher on MRI compared with CTlow-dose (p < 0.006). Nodal and osseous metastases of PC are accurately and reliably depicted by hybrid PET/MRI using (68)Ga-PSMA-11 with very low discordance compared with PET/CT including PET-positive LNs of normal size. The correlation between PET/MRI SUVs and PET/CT SUVs was linear in LN and bone metastases but was significantly lower in control (non-metastatic) tissue.
Carr, Robert; Fanti, Stefano; Paez, Diana; Cerci, Juliano; Györke, Tamás; Redondo, Francisca; Morris, Tim P; Meneghetti, Claudio; Auewarakul, Chirayu; Nair, Reena; Gorospe, Charity; Chung, June-Key; Kuzu, Isinsu; Celli, Monica; Gujral, Sumeet; Padua, Rose Ann; Dondi, Maurizio
2014-12-01
The International Atomic Energy Agency sponsored a large, multinational, prospective study to further define PET for risk stratification of diffuse large B-cell lymphoma and to test the hypothesis that international biological diversity or diversity of healthcare systems may influence the kinetics of treatment response as assessed by interim PET (I-PET). Cancer centers in Brazil, Chile, Hungary, India, Italy, the Philippines, South Korea, and Thailand followed a common protocol based on treatment with R-CHOP (cyclophosphamide, hydroxyadriamycin, vincristine, prednisolone with rituximab), with I-PET after 2-3 cycles of chemotherapy and at the end of chemotherapy scored visually. Two-year survivals for all 327 patients (median follow-up, 35 mo) were 79% (95% confidence interval [CI], 74%-83%) for event-free survival (EFS) and 86% (95% CI, 81%-89%) for overall survival (OS). Two hundred ten patients (64%) were I-PET-negative, and 117 (36%) were I-PET-positive. Two-year EFS was 90% (95% CI, 85%-93%) for I-PET-negative and 58% (95% CI, 48%-66%) for I-PET-positive, with a hazard ratio of 5.31 (95% CI, 3.29-8.56). Two-year OS was 93% (95% CI, 88%-96%) for I-PET-negative and 72% (95% CI, 63%-80%) for I-PET-positive, with a hazard ratio of 3.86 (95% CI, 2.12-7.03). On sequential monitoring, 192 of 312 (62%) patients had complete response at both I-PET and end-of-chemotherapy PET, with an EFS of 97% (95% CI, 92%-98%); 110 of these with favorable clinical indicators had an EFS of 98% (95% CI, 92%-100%). In contrast, the 107 I-PET-positive cases segregated into 2 groups: 58 (54%) achieved PET-negative complete remission at the end of chemotherapy (EFS, 86%; 95% CI, 73%-93%); 46% remained PET-positive (EFS, 35%; 95% CI, 22%-48%). Heterogeneity analysis found no significant difference between countries for outcomes stratified by I-PET. This large international cohort delivers 3 novel findings: treatment response assessed by I-PET is comparable across disparate healthcare systems, secondly a negative I-PET findings together with good clinical status identifies a group with an EFS of 98%, and thirdly a single I-PET scan does not differentiate chemoresistant lymphoma from complete response and cannot be used to guide risk-adapted therapy. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Least-squares dual characterization for ROI assessment in emission tomography
NASA Astrophysics Data System (ADS)
Ben Bouallègue, F.; Crouzet, J. F.; Dubois, A.; Buvat, I.; Mariano-Goulart, D.
2013-06-01
Our aim is to describe an original method for estimating the statistical properties of regions of interest (ROIs) in emission tomography. Drawn upon the works of Louis on the approximate inverse, we propose a dual formulation of the ROI estimation problem to derive the ROI activity and variance directly from the measured data without any image reconstruction. The method requires the definition of an ROI characteristic function that can be extracted from a co-registered morphological image. This characteristic function can be smoothed to optimize the resolution-variance tradeoff. An iterative procedure is detailed for the solution of the dual problem in the least-squares sense (least-squares dual (LSD) characterization), and a linear extrapolation scheme is described to compensate for sampling partial volume effect and reduce the estimation bias (LSD-ex). LSD and LSD-ex are compared with classical ROI estimation using pixel summation after image reconstruction and with Huesman's method. For this comparison, we used Monte Carlo simulations (GATE simulation tool) of 2D PET data of a Hoffman brain phantom containing three small uniform high-contrast ROIs and a large non-uniform low-contrast ROI. Our results show that the performances of LSD characterization are at least as good as those of the classical methods in terms of root mean square (RMS) error. For the three small tumor regions, LSD-ex allows a reduction in the estimation bias by up to 14%, resulting in a reduction in the RMS error of up to 8.5%, compared with the optimal classical estimation. For the large non-specific region, LSD using appropriate smoothing could intuitively and efficiently handle the resolution-variance tradeoff.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 6 2014-01-01 2014-01-01 false Pets. 502.11 Section 502.11 Agriculture Regulations of... CONDUCT ON BELTSVILLE AGRICULTURE RESEARCH CENTER PROPERTY, BELTSVILLE, MARYLAND § 502.11 Pets. Pets... vaccinations. Pets that are the property of employees residing on BARC must be up to date on their vaccinations...
24 CFR 5.350 - Mandatory pet rules for housing programs.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Mandatory pet rules for housing... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Pet Ownership for the Elderly or Persons With Disabilities Pet Ownership Requirements for Housing Programs § 5.350 Mandatory pet rules for...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 6 2012-01-01 2012-01-01 false Pets. 502.11 Section 502.11 Agriculture Regulations of... CONDUCT ON BELTSVILLE AGRICULTURE RESEARCH CENTER PROPERTY, BELTSVILLE, MARYLAND § 502.11 Pets. Pets... vaccinations. Pets that are the property of employees residing on BARC must be up to date on their vaccinations...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Pets. 1002.15 Section 1002.15....15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public building, public... possession of pets by the Board. This paragraph shall not apply to guide dogs accompanying visually impaired...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Pets. 1002.15 Section 1002.15....15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public building, public... possession of pets by the Board. This paragraph shall not apply to guide dogs accompanying visually impaired...
24 CFR 5.350 - Mandatory pet rules for housing programs.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Mandatory pet rules for housing... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Pet Ownership for the Elderly or Persons With Disabilities Pet Ownership Requirements for Housing Programs § 5.350 Mandatory pet rules for...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Pets. 1002.15 Section 1002.15....15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public building, public... possession of pets by the Board. This paragraph shall not apply to guide dogs accompanying visually impaired...
24 CFR 5.350 - Mandatory pet rules for housing programs.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Mandatory pet rules for housing... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Pet Ownership for the Elderly or Persons With Disabilities Pet Ownership Requirements for Housing Programs § 5.350 Mandatory pet rules for...
24 CFR 5.350 - Mandatory pet rules for housing programs.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Mandatory pet rules for housing... and Urban Development GENERAL HUD PROGRAM REQUIREMENTS; WAIVERS Pet Ownership for the Elderly or Persons With Disabilities Pet Ownership Requirements for Housing Programs § 5.350 Mandatory pet rules for...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 6 2013-01-01 2013-01-01 false Pets. 502.11 Section 502.11 Agriculture Regulations of... CONDUCT ON BELTSVILLE AGRICULTURE RESEARCH CENTER PROPERTY, BELTSVILLE, MARYLAND § 502.11 Pets. Pets... vaccinations. Pets that are the property of employees residing on BARC must be up to date on their vaccinations...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 6 2011-01-01 2011-01-01 false Pets. 502.11 Section 502.11 Agriculture Regulations of... CONDUCT ON BELTSVILLE AGRICULTURE RESEARCH CENTER PROPERTY, BELTSVILLE, MARYLAND § 502.11 Pets. Pets... vaccinations. Pets that are the property of employees residing on BARC must be up to date on their vaccinations...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Pets. 502.11 Section 502.11 Agriculture Regulations of... CONDUCT ON BELTSVILLE AGRICULTURE RESEARCH CENTER PROPERTY, BELTSVILLE, MARYLAND § 502.11 Pets. Pets... vaccinations. Pets that are the property of employees residing on BARC must be up to date on their vaccinations...
Use of PET/CT scanning in cancer patients: technical and practical considerations
2005-01-01
This overview of the oncologic applications of positron emission tomography (PET) focuses on the technical aspects and clinical applications of a newer technique: the combination of a PET scanner and a computed tomography (CT) scanner in a single (PET/CT) device. Examples illustrate how PET/CT contributes to patient care and improves upon the previous state-of-the-art method of comparing a PET scan with a separate CT scan. Finally, the author presents some of the results from studies of PET/CT imaging that are beginning to appear in the literature. PMID:16252023
J-PET: A New Technology for the Whole-body PET Imaging
NASA Astrophysics Data System (ADS)
Niedźwiecki, S.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kapłon, Ł.; Kisielewska-Kamińska, D.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krawczyk, N.; Krzemień, W.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Pałka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Shopa, R. Y.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.
Hope, Thomas A; Afshar-Oromieh, Ali; Eiber, Matthias; Emmett, Louise; Fendler, Wolfgang P; Lawhn-Heath, Courtney; Rowe, Steven P
2018-06-27
The purpose of this article is to describe the large number of radiotracers being evaluated for prostate-specific membrane antigen (PSMA) PET, which is becoming a central tool in the staging of prostate cancer. PSMA PET is a highly promising modality for the staging of prostate cancer because of its higher detection rate compared with that of conventional imaging. Both PET/CT and PET/MRI offer benefits with PSMA radiotracers, and PSMA PET findings frequently lead to changes in management. It is imperative that subsequent treatment changes be evaluated to show improved outcomes. PSMA PET also has potential applications, including patient selection for PSMA-based radioligand therapy and evaluation of treatment response.
Krause-Parello, Cheryl A
2012-01-01
Pets can play a positive role in the both the physical and psychological health of older adults. This cross sectional study investigated the relationships among loneliness, pet attachment support, human social support, and depressed mood in a convenience sample of 159 pet-owning older women residing in the community. Participants completed loneliness, pet attachment support, human social support, and depressed mood scales. The results supported significant relationships between loneliness, pet attachment support, human social support, and depressed mood. No relationship was found between human social support and depressed mood. Pet attachment support, but not human social support, influenced the relationship between loneliness and depressed mood indicating the importance of pet attachment as a greater form of support in this sample. Clinical and social implications for nurses working with the geriatric population were identified and discussed. Copyright © 2012 Mosby, Inc. All rights reserved.
Effect of household pet ownership on infant immune response and subsequent sensitization
Simpson, Angela
2010-01-01
Sensitization to pets is a major risk factor for asthma. There are many reports on the relationship between household pets, sensitization to the pet, and sensitization to other allergens, often with conflicting results. Pet ownership is not random, and household pets are associated with exposures other than pet allergens. We will review some of the evidence regarding the effects of household pets on infant immune responses, focusing on data from birth cohort studies. It remains unclear precisely why some children develop specific sensitizations to pets whilst others do not in the face of equivalent exposures, but it is likely to be due to gene-environment interactions. Further long-term follow-up of children in whom neonatal and infant immune responses have been measured is necessary to understand how these events occur and how they relate to subsequent disease. PMID:21437047
18F-FDG PET/CT in Detecting Metastatic Infection in Children.
Kouijzer, Ilse J E; Blokhuis, Gijsbert J; Draaisma, Jos M T; Oyen, Wim J G; de Geus-Oei, Lioe-Fee; Bleeker-Rovers, Chantal P
2016-04-01
Metastatic infection is a severe complication of bacteremia with high morbidity and mortality. The aim of this study was to investigate the diagnostic value of 18F-FDG PET combined with CT (FDG PET/CT) in children suspected of having metastatic infection. The results of FDG PET/CT scans performed in children because of suspected metastatic infection from September 2003 to June 2013 were analyzed retrospectively. The results were compared with the final clinical diagnosis. FDG PET/CT was performed in 13 children with suspected metastatic infection. Of the total number of FDG PET/CT scans, 38% were clinically helpful. Positive predictive value of FDG PET/CT was 71%, and negative predictive value was 100%. FDG PET/CT appears to be a valuable diagnostic technique in children with suspected metastatic infection. Prospective studies of FDG PET/CT as part of a structured diagnostic protocol are needed to assess the exact additional diagnostic value.
Jagust, William J.; Landau, Susan M.; Koeppe, Robert A.; Reiman, Eric M.; Chen, Kewei; Mathis, Chester A.; Price, Julie C.; Foster, Norman L.; Wang, Angela Y.
2015-01-01
INTRODUCTION This paper reviews the work done in the ADNI PET core over the past 5 years, largely concerning techniques, methods, and results related to amyloid imaging in ADNI. METHODS The PET Core has utilized [18F]florbetapir routinely on ADNI participants, with over 1600 scans available for download. Four different laboratories are involved in data analysis, and have examined factors such as longitudinal florbetapir analysis, use of FDG-PET in clinical trials, and relationships between different biomarkers and cognition. RESULTS Converging evidence from the PET Core has indicated that cross-sectional and longitudinal florbetapir analyses require different reference regions. Studies have also examined the relationship between florbetapir data obtained immediately after injection, which reflects perfusion, and FDG-PET results. Finally, standardization has included the translation of florbetapir PET data to a centiloid scale. CONCLUSION The PET Core has demonstrated a variety of methods for standardization of biomarkers such as florbetapir PET in a multicenter setting. PMID:26194311
Abarca V, Katia; López Del P, Javier; Peña D, Anamaría; López G, J Carlos
2011-06-01
To characterize pet ownership and pet health status in families of immunocompromised (IS) children, with emphasis in zoonotic diseases. Families of IS children from two hospitals in Santiago, Chile, were interviewed and their pets were evaluated by veterinary examination, coproparasitologic and skin dermatophytes test. In specific cases, other laboratory tests were performed in IS children or their relatives. 47 out of 70 contacted families had pets, 42 participated in the study. Several risk factors for IS children were observed, as having a turtle as a pet and to clean cat or turtle faeces. Lack of adequate veterinary control, immunizations and deparasitation of pets were observed. Some animals showed zoonotic diseases or agents, as Brucella canis, Cryptosporidium sp, Giardia intestinalis, Toxocara canis and scabies. 44% of dogs had ticks and 37% had fleas, both potential vectors of infections. Our results suggest that policies to provide safer pet contact in IS children are needed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaonkar, Amita, E-mail: ami.gaonkar@gmail.com; Murudkar, Vrishali, E-mail: vru0077@gmail.com; Deshpande, V. D., E-mail: vindesh2@rediffmail.com
2016-05-06
Polyethylene terephthalate (PET) and Nucleated PET/ multi-walled carbon nanotubes (MWCNTs) nanocomposites with different MWCNTs loadings were prepared by melt compounding. The influence of the addition of MWCNTs and precipitated PET (p-PET) on the morphology and thermal properties of the nanocomposites was investigated. From Transmission Electronic Microscopy (TEM) and Wide angle X-Ray diffraction (WAXD) study, it can be clearly seen that nanocomposites with low MWCNTs contents (0.1 wt. %) get better MWCNTs dispersion than higher MWCNT loading. Comparing with PET, nucleated PET nanocomposite with 0.1% MWCNT loading shows higher value of Lauritzen-Hoffman parameters U* and Kg evaluated using the differential isoconversionalmore » method. Crystallization regime transition temperature range shifts to higher temperature (208°C - 215°C) for nanocomposites. The presence of p-PET in addition of MWCNT, which act as good nucleating agent, enhanced the crystallization of PET through heterogeneous nucleation.« less
NASA Astrophysics Data System (ADS)
Gaonkar, Amita; Murudkar, Vrishali; Deshpande, V. D.
2016-05-01
Polyethylene terephthalate (PET) and Nucleated PET/ multi-walled carbon nanotubes (MWCNTs) nanocomposites with different MWCNTs loadings were prepared by melt compounding. The influence of the addition of MWCNTs and precipitated PET (p-PET) on the morphology and thermal properties of the nanocomposites was investigated. From Transmission Electronic Microscopy (TEM) and Wide angle X-Ray diffraction (WAXD) study, it can be clearly seen that nanocomposites with low MWCNTs contents (0.1 wt. %) get better MWCNTs dispersion than higher MWCNT loading. Comparing with PET, nucleated PET nanocomposite with 0.1% MWCNT loading shows higher value of Lauritzen-Hoffman parameters U* and Kg evaluated using the differential isoconversional method. Crystallization regime transition temperature range shifts to higher temperature (208°C - 215°C) for nanocomposites. The presence of p-PET in addition of MWCNT, which act as good nucleating agent, enhanced the crystallization of PET through heterogeneous nucleation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laforest, R.
2015-06-15
The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applicationsmore » that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.« less
[A report on clinical PET activities in Germany].
Tashiro, M; Kubota, K; Itoh, M; Sasaki, H; Moser, E
1999-09-01
Clinical diagnostic procedure using positron emission tomography (PET) requires high costs. To promote clinical use of PET, sociomedical evaluation is necessary. In this paper, sociomedical situations concerning clinical use of PET in Germany is reported. Some comparisons are made between Japan and this country putting emphases on several points such as 1) number of cyclotron and PET facilities, 2) social restriction to transportation of radioisotopes, 3) activities of satellite PET facilities, and 4) clinical indications for PET studies. Number of cyclotron was larger in Japan (29) than in Germany (17), but number of PET facilities was larger in Germany (47) than in Japan (29). The reason seems that in Germany transportation and buying of radioisotopes is less restricted. Hence, more than half of PET facilities in Germany are "satellite facilities" which do not have their own cyclotrons. Radioisotope distribution seems to serve as a backbone of "satellite concept." Additionally in Germany, list of clinical indications for PET study is almost completed and now is widely in applied to most cases. To promote clinical use of PET in Japan, the German system might serve as an important socioeconomic model in Europe instead of the United States.
Implement of the Owner Distinction Function for Healing-Type Pet Robots
NASA Astrophysics Data System (ADS)
Nambo, Hidetaka; Kimura, Haruhiko; Hirose, Sadaki
In recent years, a robotics technology is extremely progressive, and robots are widely applied in many fields. One of the most typical robots is a pet robot. The pet robot is based on an animal pet, such as a dog or a cat. Also, it is known that an animal pet has a healing effect. Therefore, the study to apply pet robots to Animal Assisted Therapy instead of an animal pet has begun to be investigated. We, also, have investigated a method of an owner distinction for pet robot, to emphasize a healing effect of pet robots. In this paper, taking account of implementation into pet robots, a real-time owner distinction method is proposed. In the concrete, the method provides a real-time matching algorithm and an oblivion mechanism. The real-time matching means that a matching and a data acquisition are processed simultaneously. The oblivion mechanism is deleting features of owners in the database of the pet robots. Additionally, the mechanism enables to reduce matching costs or size of database and it enables to follow a change of owners. Furthermore, effectivity and a practicality of the method are evaluated by experiments.
Bagci, Ulas; Udupa, Jayaram K.; Mendhiratta, Neil; Foster, Brent; Xu, Ziyue; Yao, Jianhua; Chen, Xinjian; Mollura, Daniel J.
2013-01-01
We present a novel method for the joint segmentation of anatomical and functional images. Our proposed methodology unifies the domains of anatomical and functional images, represents them in a product lattice, and performs simultaneous delineation of regions based on random walk image segmentation. Furthermore, we also propose a simple yet effective object/background seed localization method to make the proposed segmentation process fully automatic. Our study uses PET, PET-CT, MRI-PET, and fused MRI-PET-CT scans (77 studies in all) from 56 patients who had various lesions in different body regions. We validated the effectiveness of the proposed method on different PET phantoms as well as on clinical images with respect to the ground truth segmentation provided by clinicians. Experimental results indicate that the presented method is superior to threshold and Bayesian methods commonly used in PET image segmentation, is more accurate and robust compared to the other PET-CT segmentation methods recently published in the literature, and also it is general in the sense of simultaneously segmenting multiple scans in real-time with high accuracy needed in routine clinical use. PMID:23837967
Pettinato, C; Nanni, C; Farsad, M; Castellucci, P; Sarnelli, A; Civollani, S; Franchi, R; Fanti, S; Marengo, M; Bergamini, C
2006-01-01
Positron emission tomography (PET) is a non-invasive imaging modality, which is clinically widely used both for diagnosis and accessing therapy response in oncology, cardiology and neurology. Fusing PET and CT images in a single dataset would be useful for physicians who could read the functional and the anatomical aspects of a disease in a single shot. The use of fusion software has been replaced in the last few years by integrated PET/CT systems, which combine a PET and a CT scanner in the same gantry. CT images have the double function to correct PET images for attenuation and can fuse with PET for a better visualization and localization of lesions. The use of CT for attenuation correction yields several advantages in terms of accuracy and patient comfort, but can also introduce several artefacts on PET-corrected images. PET/CT image artefacts are due primarily to metallic implants, respiratory motion, use of contrast media and image truncation. This paper reviews different types artefacts and their correction methods. PET/CT improves image quality and image accuracy. However, to avoid possible pitfalls the simultaneous display of both Computed Tomography Attenuation Corrected (CTAC) and non corrected PET images, side by side with CT images is strongly recommended. PMID:21614340
Queiroz, Marcelo A; Barbosa, Felipe de Galiza; Buchpiguel, Carlos Alberto; Cerri, Giovanni Guido
2018-01-01
The new technology of PET/MRI is a prototype of hybrid imaging, allowing for the combination of molecular data from PET scanning and morphofunctional information derived from MRI scanning. Recent advances regarding the technical aspects of this device, especially after the development of MRI-compatible silicon photomultipliers of PET, permitted an increase in the diagnostic performance of PET/MRI translated into dose reduction and higher imaging quality. Among several clinical applications, PET/MRI gains ground initially in oncology, where MRI per se plays an essential role in the assessment of primary tumors (which is limited in the case of PET/CT), including prostate, rectal and gynecological tumors. On the other hand, the evaluation of the lungs remains an enigma although new MRI sequences are being designed to overcome this. More clinical indications of PET/MRI are seen in the fields of neurology, cardiology and inflammatory processes, and the use of PET/MRI also opens perspectives for pediatric populations as it involves very low radiation exposure. Our review aimed to highlight the current indications of PET/MRI and discuss the challenges and perspectives of PET/MRI at HC-FMUSP.
Hansson, Nils Henrik; Tolbod, Lars; Harms, Johannes; Wiggers, Henrik; Kim, Won Yong; Hansen, Esben; Zaremba, Tomas; Frøkiær, Jørgen; Jakobsen, Steen; Sørensen, Jens
2016-08-01
Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P < .001 for all), but were underestimated by PET (P < .001 for all except ESV P = .79). PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P < .001, bias -3 ± 21%, P = .56). PET-based MEE bias was strongly associated with LV wall thickness. Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.
TH-A-17A-01: Innovation in PET Instrumentation and Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casey, M; Miyaoka, R; Shao, Y
Innovation in PET instrumentation has led to the new millennium revolutionary imaging applications for diagnosis, therapeutic guidance, and development of new molecular imaging probes, etc. However, after several decades innovations, will the advances of PET technology and applications continue with the same trend and pace? What will be the next big thing beyond the PET/CT, PET/MRI, and Time-of-flight PET? How will the PET instrumentation and imaging performance be further improved by novel detector research and advanced imaging system development? Or will the development of new algorithms and methodologies extend the limit of current instrumentation and leapfrog the imaging quality andmore » quantification for practical applications? The objective of this session is to present an overview of current status and advances in the PET instrumentation and applications with speakers from leading academic institutes and a major medical imaging company. Presenting with both academic research projects and commercial technology developments, this session will provide a glimpse of some latest advances and challenges in the field, such as using semiconductor photon-sensor based PET detectors to improve performance and enable new applications, as well as the technology trend that may lead to the next breakthrough in PET imaging for clinical and preclinical applications. Both imaging and image-guided therapy subjects will be discussed. Learning Objectives: Describe the latest innovations in PET instrumentation and applications Understand the driven force behind the PET instrumentation innovation and development Learn the trend of PET technology development for applications.« less
Treglia, Giorgio; Annunziata, Salvatore; Muoio, Barbara; Salvatori, Massimo; Ceriani, Luca; Giovanella, Luca
2013-01-01
Aggressive histological subtypes of thyroid cancer are rare and have a poor prognosis. The most important aggressive subtypes of thyroid cancer are Hürthle cell carcinoma (HCTC) and anaplastic and poorly differentiated carcinoma (ATC and PDTC). The American Thyroid Association recently published guidelines for the management of patients with ATC, but no specific guidelines have been done about HCTC. We performed an overview of the literature about the role of Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography (FDG-PET or PET/CT) in aggressive histological subtypes of thyroid cancer. Only few original studies about the role of FDG-PET or PET/CT in HCTC, PDTC, and ATC have been published in the literature. FDG-PET or PET/CT seems to be useful in staging or followup of invasive and metastatic HCTC. FDG-PET or PET/CT should be used in patients with ATC in initial staging and in the followup after surgery to evaluate metastatic disease. Some authors suggest the use of FDG-PET/CT in staging of PDTC, but more studies are needed to define the diagnostic use of FDG-PET/CT in this setting. Limited experience suggests the usefulness of FDG-PET or PET/CT in patients with more aggressive histological subtypes of DTC. However, DTC presenting as radioiodine refractory and FDG-PET positive should be considered aggressive tumours with poor prognosis. PMID:23653645
Dodd, Emily; Cheston, Richard; Procter, Charlie; Heneker, Sarah; Gray, Richard; Fox, Chris; Nolan, Fiona
2018-04-01
During protected engagement time (PET), ward routines are adjusted so that staff can spend time together with patients without interruption. The aim of PET is to increase staff and patient interaction on wards, and ultimately patient well-being. Although PET has been implemented on inpatient wards within the UK, including older adult wards, there is no systematic evidence as to how PET is carried out or how it is experienced by staff, patients, and families. Semistructured interviews were conducted with 28 participants (8 patients, 10 family members, and 10 ward staff) from three different wards with PET, and transcriptions were analysed using thematic analysis. Three themes were identified: (i) the patient is at the heart of care; (ii) PET depends on staff; and (iii) tensions in how PET operates. There was support in our sample for the principles of PET and its potential for a positive impact on patient well-being. However, the implementation of PET was identified as challenging, highlighting an existing tension between an individual's needs and the wider needs of patients on the ward as a whole. The impact of PET was generally described as being dependent on how PET was organized and the level of staff commitment to PET. Participants emphasized that if PET is to be successful, then it should be a fluid process that fits in with the local context. © 2017 Australian College of Mental Health Nurses Inc.
NASA Astrophysics Data System (ADS)
Ahmed, Abdella M.; Tashima, Hideaki; Yoshida, Eiji; Nishikido, Fumihiko; Yamaya, Taiga
2017-06-01
There is a growing interest in developing brain PET scanners with high sensitivity and high spatial resolution for early diagnosis of neurodegenerative diseases and studies of brain functions. Sensitivity of the PET scanner can be improved by increasing the solid angle. However, conventional PET scanners are designed based on a cylindrical geometry, which may not be the most efficient design for brain imaging in terms of the balance between sensitivity and cost. We proposed a dedicated brain PET scanner based on a hemispheric shape detector and a chin detector (referred to as the helmet-chin PET), which is designed to maximize the solid angle by increasing the number of lines-of-response in the hemisphere. The parallax error, which PET scanners with a large solid angle tend to have, can be suppressed by the use of depth-of-interaction detectors. In this study, we carry out a realistic evaluation of the helmet-chin PET using Monte Carlo simulation based on the 4-layer GSO detector which consists of a 16 × 16 × 4 array of crystals with dimensions of 2.8 × 2.8 × 7.5 mm3. The purpose of this simulation is to show the gain in imaging performance of the helmet-chin PET compared with the cylindrical PET using the same number of detectors in each configuration. The sensitivity of the helmet-chin PET evaluated with a cylindrical phantom has a significant increase, especially at the top of the (field-of-view) FOV. The peak-NECR of the helmet-chin PET is 1.4 times higher compared to the cylindrical PET. The helmet-chin PET provides relatively low noise images throughout the FOV compared to the cylindrical PET which exhibits enhanced noise at the peripheral regions. The results show the helmet-chin PET can significantly improve the sensitivity and reduce the noise in the reconstructed images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, J; Natwa, M; Hall, NC
Purpose: The longer patient has to remain on the table during PET imaging, the higher the likelihood of motion artifacts due to patient discomfort. This study was to investigate and optimize PET acquisition overlap in 18F-FDG oncology wholebody PET/CT to speed up PET acquisition and improve patient comfort. Methods: Wholebody 18F-FDG PET/CT of phantoms, 8 pre-clinical patients (beagles) and 5 clinical oncology patients were performed in 90s/bed on a time-of-flight Gemini TF 64 system. Imaging of phantoms and beagles was acquired with reduced PET overlaps (40%, 33%, 27%, 20%, 13% and no overlap) in addition to the system default (53%).more » In human studies, 1 or 2 reduced overlaps from the listed options were used to acquire PET/CT sweeps right after the default standard of care imaging. Image quality was blindly reviewed using visual scoring criteria and quantitative SUV assessment. NEMA PET sensitivity was performed under different overlaps. Results: All PET exams demonstrated no significant impact on the visual grades for overlaps >20%. Blinded reviews assigned the best visual scores to PET using overlaps 53%–27%. Reducing overlap to 27% for oncology patients (12-bed) saved an average of ∼40% acquisition time (11min) compared to using the default overlap (18min). No significant SUV variances were found when reducing overlap to half of default for cerebellum, lung, heart, aorta, liver, fat, muscle, bone marrow, thighs and target lesions (p>0.05), except expected variability in urinary system. Conclusion: This study demonstrated by combined phantom, pre-clinical and clinical PET/CT scans that PET acquisition overlap in axial of today’s systems can be reduced and optimized. It showed that a reduction of PET acquisition overlap to 27% (half of system default) can be implemented to reduce table time by ∼40% to improve patient comfort and minimize potential motion artifacts, without prominently degrading image quality or compromising PET quantification.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nawrocki, J; Chino, J; Light, K
2014-06-01
Purpose: To compare PET extracted metrics and investigate the role of a gradient-based PET segmentation tool, PET Edge (MIM Software Inc., Cleveland, OH), in the context of an adaptive PET protocol for node positive gynecologic cancer patients. Methods: An IRB approved protocol enrolled women with gynecological, PET visible malignancies. A PET-CT was obtained for treatment planning prescribed to 45–50.4Gy with a 55– 70Gy boost to the PET positive nodes. An intra-treatment PET-CT was obtained between 30–36Gy, and all volumes re-contoured. Standard uptake values (SUVmax, SUVmean, SUVmedian) and GTV volumes were extracted from the clinician contoured GTVs on the pre- andmore » intra-treament PET-CT for primaries and nodes and compared with a two tailed Wilcoxon signed-rank test. The differences between primary and node GTV volumes contoured in the treatment planning system and those volumes generated using PET Edge were also investigated. Bland-Altman plots were used to describe significant differences between the two contouring methods. Results: Thirteen women were enrolled in this study. The median baseline/intra-treatment primary (SUVmax, mean, median) were (30.5, 9.09, 7.83)/( 16.6, 4.35, 3.74), and nodes were (20.1, 4.64, 3.93)/( 6.78, 3.13, 3.26). The p values were all < 0.001. The clinical contours were all larger than the PET Edge generated ones, with mean difference of +20.6 ml for primary, and +23.5 ml for nodes. The Bland-Altman revealed changes between clinician/PET Edge contours to be mostly within the margins of the coefficient of variability. However, there was a proportional trend, i.e. the larger the GTV, the larger the clinical contours as compared to PET Edge contours. Conclusion: Primary and node SUV values taken from the intratreament PET-CT can be used to assess the disease response and to design an adaptive plan. The PET Edge tool can streamline the contouring process and lead to smaller, less user-dependent contours.« less
Oturai, Peter S; Mortensen, Jann; Enevoldsen, Henriette; Eigtved, Annika; Backer, Vibeke; Olesen, Knud P; Nielsen, Henrik W; Hansen, Hanne; Stentoft, Poul; Friberg, Lars
2004-08-01
It is not clear whether high-quality coincidence gamma-PET (gPET) cameras can provide clinical data comparable with data obtained with dedicated PET (dPET) cameras in the primary diagnostic work-up of patients with suspected lung cancer. This study focuses on 2 main issues: direct comparison between foci resolved with the 2 different PET scanners and the diagnostic accuracy compared with final diagnosis determined by the combined information from all other investigations and clinical follow-up. Eighty-six patients were recruited to this study through a routine diagnostic program. They all had changes on their chest radiographs, suggesting malignant lung tumor. In addition to the standard diagnostic program, each patient had 2 PET scans that were performed on the same day. After administration of 419 MBq (range = 305-547 MBq) (18)F-FDG, patients were scanned in a dedicated PET scanner about 1 h after FDG administration and in a dual-head coincidence gamma-camera about 3 h after tracer injection. Images from the 2 scans were evaluated in a blinded set-up and compared with the final outcome. Malignant intrathoracic disease was found in 52 patients, and 47 patients had primary lung cancers. dPET detected all patients as having malignancies (sensitivity, 100%; specificity, 50%), whereas gPET missed one patient (sensitivity, 98%; specificity, 56%). For evaluating regional lymph node involvement, sensitivity and specificity rates were 78% and 84% for dPET and 61% and 90% for gPET, respectively. When comparing the 2 PET techniques with clinical tumor stage (TNM), full agreement was obtained in 64% of the patients (Cohen's kappa = 0.56). Comparing categorization of the patients into clinical relevant stages (no malignancy/malignancy suitable for treatment with curative intent/nontreatable malignancy), resulted in full agreement in 81% (Cohen's kappa = 0.71) of patients. Comparing results from a recent generation of gPET cameras obtained about 2 h later than those of dPET, there was a fairly good agreement with regard to detecting primary lung tumors but slightly reduced sensitivity in detecting smaller malignant lesions such as lymph nodes. Depending on the population to be investigated, and if dPET is not available, gPET might provide significant diagnostic information in patients in whom lung cancer is suspected.