Sample records for cleaning demonstration test

  1. DEMONSTRATION OF A LIQUID CARBON DIOXIDE PROCESS FOR CLEANING METAL PARTS

    EPA Science Inventory

    The report gives results of a demonstration of liquid carbon dioxide (LCO2) as an alternative to chlorinated solvents for cleaning metal parts. It describes the LCO2 process, the parts tested, the contaminants removed, and results from preliminary laboratory testing and on-site d...

  2. "Magic Eraser" Flame Tests

    ERIC Educational Resources Information Center

    Landis, Arthur M.; Davies, Malonne I.; Landis, Linda

    2009-01-01

    Cleaning erasers are used to support methanol-fueled flame tests. This safe demonstration technique requires only small quantities of materials, provides clean colors for up to 45 seconds, and can be used in the classroom or the auditorium. (Contains 1 note.)

  3. Quantitative assessment of the efficacy of spiral-wound membrane cleaning procedures to remove biofilms.

    PubMed

    Hijnen, W A M; Castillo, C; Brouwer-Hanzens, A H; Harmsen, D J H; Cornelissen, E R; van der Kooij, D

    2012-12-01

    Cleaning of high pressure RO/NF membranes is an important operational tool to control biofouling. Quantitative information on the efficacy of cleaning agents and protocols to remove biomass is scarce. Therefore, a laboratory cleaning test to assess the efficiency of cleaning procedures to remove attached biomass was developed. The major components of the test are (i) production of uniform biofilm samples, (ii) the quantification of the biomass concentrations with robust parameters and (iii) a simple test procedure with optimal exposure of the biofilm samples to the chemicals. The results showed that PVC-P is a suitable substratum for the production of uniform biofilm samples. ATP and carbohydrates (CH) as major components of the biofilm matrix for nucleotides (living bacterial cells) and extracellular polymeric substances EPS, respectively, were selected as robust biomass parameters. The removal of ATP and CH with the NaOH/Sodium Dodecyl Sulfate (SDS) mixture, selected as a standard treatment at pH 12.0, was reproducible. The resistance of the EPS matrix against chemical cleaning was demonstrated by a low CH removal (32.8 ± 6.0%) compared to the ATP removal (70.5 ± 15.1%). The inverse relationship of biomass removal with the CH to ATP ratio (μg/ng) of the biofilms demonstrated the influence of the biomass characteristics on cleaning. None of the 27 chemicals tested (analytical-grade and commercial brands) in single step or in double-step treatments were significantly more effective than NaOH/SDS. Oxidizing agents NaOCl and H(2)O(2), the latter in combination with SDS, both tested as common agents in biofilm control, showed a significantly higher efficiency (70%) to remove biofilms. In the test, simultaneously, the efficiency of agents to remove precipitated minerals such as Fe can be assessed. Validation tests with Cleaning in Place (CIP) in 8 and 2.5-inch RO membrane pilot plant experiments showed similar ranking of the cleaning efficiency of cleaning protocols as determined in the laboratory tests. Further studies with the laboratory test are required to study the effect of cleaning conditions such as duration, temperature, shear forces as well as chemical conditions (concentrations, alternative agents or mixtures and sequence of application) on the efficiency to remove attached biomass. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Laboratory demonstration model: Active cleaning technique device. [for removal of contaminants from an optical surface

    NASA Technical Reports Server (NTRS)

    Shannon, R. L.; Gillette, R. B.

    1974-01-01

    The technique which utilizes exposure to a plasma to remove contaminants from a surface was incorporated into a laboratory model which demonstrates active cleaning by both plasma cleaning and ion sputtering modes of operation. The development phase is reported and includes discussion of the plasma tube configuration, device design, and performance tests. A general description of the active cleaning device is provided which includes information on the main power/plasma discharge sensors, and the power, gas supply, and ion accelerator systems. Development of the active cleaning species at high vacuum conditions is described and results indicate that plasma cleaning occurs in the region of a visible plume which extends from the end of the plasma tube. Recommendations are made for research to determine the plasma cleaning mechanism and the plasma species responsible for the cleaning, as well limitations on the type of contaminants that can be removed.

  5. The Clean Coal Technology Program 100 MWe demonstration of gas suspension absorption for flue gas desulfurization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, F.E.; Hedenhag, J.G.; Marchant, S.K.

    1997-12-31

    AirPol Inc., with the cooperation of the Tennessee Valley Authority (TVA) under a Cooperative Agreement with the United States Department of Energy, installed and tested a 10 MWe Gas Suspension Absorption (GSA) Demonstration system at TVA`s Shawnee Fossil Plant near Paducah, Kentucky. This low-cost retrofit project demonstrated that the GSA system can remove more than 90% of the sulfur dioxide from high-sulfur coal-fired flue gas, while achieving a relatively high utilization of reagent lime. This paper presents a detailed technical description of the Clean Coal Technology demonstration project. Test results and data analysis from the preliminary testing, factorial tests, airmore » toxics texts, 28-day continuous demonstration run of GSA/electrostatic precipitator (ESP), and 14-day continuous demonstration run of GSA/pulse jet baghouse (PJBH) are also discussed within this paper.« less

  6. RELIABILITY OF THE ONE REPETITION-MAXIMUM POWER CLEAN TEST IN ADOLESCENT ATHLETES

    PubMed Central

    Faigenbaum, Avery D.; McFarland, James E.; Herman, Robert; Naclerio, Fernando; Ratamess, Nicholas A.; Kang, Jie; Myer, Gregory D.

    2013-01-01

    Although the power clean test is routinely used to assess strength and power performance in adult athletes, the reliability of this measure in younger populations has not been examined. Therefore, the purpose of this study was to determine the reliability of the one repetition maximum (1 RM) power clean in adolescent athletes. Thirty-six male athletes (age 15.9 ± 1.1 yrs, body mass 79.1 ± 20.3 kg, height 175.1 ±7.4 cm) who had more than 1 year of training experience with weightlifting exercises performed a 1 RM power clean on two nonconsecutive days in the afternoon following standardized procedures. All test procedures were supervised by a senior level weightlifting coach and consisted of a systematic progression in test load until the maximum resistance that could be lifted for one repetition using proper exercise technique was determined. Data were analyzed using an intraclass correlation coefficient (ICC [2,k]), Pearson correlation coefficient (r), repeated measures ANOVA, Bland-Altman plot, and typical error analyses. Analysis of the data revealed that the test measures were highly reliable demonstrating a test-retest ICC of 0.98 (95% CI = 0.96–0.99). Testing also demonstrated a strong relationship between 1 RM measures on trial 1 and trial 2 (r=0.98, p<0.0001) with no significant difference in power clean performance between trials (70.6 ± 19.8 vs. 69.8 ± 19.8 kg). Bland Altman plots confirmed no systematic shift in 1 RM between trial 1 and trial 2. The typical error to be expected between 1 RM power clean trials is 2.9 kg and a change of at least 8.0 kg is indicated to determine a real change in lifting performance between tests in young lifters. No injuries occurred during the study period and the testing protocol was well-tolerated by all subjects. These findings indicate that 1 RM power clean testing has a high degree of reproducibility in trained male adolescent athletes when standardized testing procedures are followed and qualified instruction is present. PMID:22233786

  7. Replacement of Hydrochlorofluorocarbon (HCFC) -225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems

    NASA Technical Reports Server (NTRS)

    Mitchell, Mark A.; Lowrey, Nikki M.

    2015-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon-225 (HCFC-225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC-225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both the NASA Rocket Propulsion Test Program and the Defense Logistics Agency - Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC-225 that is both an effective cleaner and safe for use with oxygen systems. Candidate solvents were selected and a test plan was developed following the guidelines of ASTM G127, Standard Guide for the Selection of Cleaning Agents for Oxygen Systems. Solvents were evaluated for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Two solvents were determined to be acceptable for cleaning oxygen systems and one was chosen for implementation at NASA's rocket propulsion test facilities. The test program and results are summarized. This project also demonstrated the benefits of cross-agency collaboration in a time of limited resources.

  8. The adenosine triphosphate test is a rapid and reliable audit tool to assess manual cleaning adequacy of flexible endoscope channels.

    PubMed

    Alfa, Michelle J; Fatima, Iram; Olson, Nancy

    2013-03-01

    The study objective was to verify that the adenosine triphosphate (ATP) benchmark of <200 relative light units (RLUs) was achievable in a busy endoscopy clinic that followed the manufacturer's manual cleaning instructions. All channels from patient-used colonoscopes (20) and duodenoscopes (20) in a tertiary care hospital endoscopy clinic were sampled after manual cleaning and tested for residual ATP. The ATP test benchmark for adequate manual cleaning was set at <200 RLUs. The benchmark for protein was <6.4 μg/cm(2), and, for bioburden, it was <4-log10 colony-forming units/cm(2). Our data demonstrated that 96% (115/120) of channels from 20 colonoscopes and 20 duodenoscopes evaluated met the ATP benchmark of <200 RLUs. The 5 channels that exceeded 200 RLUs were all elevator guide-wire channels. All 120 of the manually cleaned endoscopes tested had protein and bioburden levels that were compliant with accepted benchmarks for manual cleaning for suction-biopsy, air-water, and auxiliary water channels. Our data confirmed that, by following the endoscope manufacturer's manual cleaning recommendations, 96% of channels in gastrointestinal endoscopes would have <200 RLUs for the ATP test kit evaluated and would meet the accepted clean benchmarks for protein and bioburden. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  9. Replacement of HCFC-225 Solvent for Cleaning NASA Propulsion Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Mitchell, Mark A.; Lowrey, Nikki M.

    2015-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon-225 (HCFC-225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC-225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both the NASA Rocket Propulsion Test Program and the Defense Logistics Agency - Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC-225 that is both an effective cleaner and safe for use with oxygen systems. Candidate solvents were selected and a test plan was developed following the guidelines of ASTM G127, Standard Guide for the Selection of Cleaning Agents for Oxygen Systems. Solvents were evaluated for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Two solvents were determined to be acceptable for cleaning oxygen systems and one was chosen for implementation at NASA's rocket propulsion test facilities. The test program and results are summarized. This project also demonstrated the benefits of cross-agency collaboration in a time of limited resources.

  10. Advanced physical fine coal cleaning: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-12-01

    The contract objective was to demonstrate Advanced Energy Dynamics, Inc., (AED) Ultrafine Coal (UFC) electrostatic physical fine coal cleaning process as capable of: producing clean coal products of no greater than 2% ash; significantly reducing the pyritic sulfur content below that achievable with state-of-the-art coal cleaning; recovering over 80% of the available energy content in the run-of-mine coal; producing product and refuse with surface moisture below 30%. Originally the demonstration was to be of a Charger/Disc System at the Electric Power Research Institute (EPRI) Coal Quality Development Center (CQDC) at Homer City, Pennsylvania. As a result of the combination ofmore » Charger/Disc System scale-up problems and parallel development of an improved Vertical-Belt Separator, DOE issued a contract modification to perform additional laboratory testing and optimization of the UFC Vertical-Belt Separator System at AED. These comparative test results, safety analyses and an economic analysis are discussed in this report. 29 refs., 25 figs., 41 tabs.« less

  11. HOMER CITY MULTISTREAM COAL CLEANING DEMONSTRATION: A PROGRESS REPORT

    EPA Science Inventory

    The report gives an overview of ongoing testing and evaluation of the Homer City Coal Cleaning Plant, built to enable the Homer City Power Complex to meet sulfur dioxide (SO2) emission levels mandated by the State of Pennsylvania and the U.S. Government. The plant was constructed...

  12. Homer City Multistream Coal Cleaning Demonstration: A progress report. Report for January 1979-July 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carey, D.W.; Higgins, S.T.; Slowik, A.A.

    1984-08-01

    The report gives an overview of ongoing testing and evaluation of the Homer City Coal Cleaning Plant, built to enable the Homer City Power Complex to meet sulfur dioxide (SO2) emission levels mandated by the State of Pennsylvania and the U.S. Government. The plant was constructed as a result of an extensive comparative evaluation of flue gas desulfurization (FGD) and physical coal cleaning. The Homer City System, the Multistream Coal Cleaning System (MCCS), was chosen as an economical alternative to FGD. The plant contains circuits for cleaning coarse, medium, and fine coals and for recovering fine and very fine coals.more » The dominant type of cleaning equipment used in the plant is the dense medium cyclone. The original '93 plant' configuration was never able to clean coal to the conditions specified in the plant design. An extensive test and evaluation program was begun to identify and correct the causes of plant operating problems. After extensive pilot plant equipment tests and engineering studies were completed, recommendations were made for plant modifications necessary to correct the design and operating deficiencies of the plant. Extensive modifications were made to one of two parallel processing trains in the plant (the 'B' circuits), and a test program was initiated to evaluate these corrective measures. The modified 'B' circuits have not yet met design conditions.« less

  13. Wash Solution Bath Life Extension for the Space Shuttle Rocket Motor Aqueous Cleaning System

    NASA Technical Reports Server (NTRS)

    Saunders, Chad; Evans, Kurt; Sagers, Neil

    1999-01-01

    A spray-in-air aqueous cleaning system, which replaced 1,1,1 trichloroethane (TCA) vapor degreasing, is used for critical cleaning of Space Shuttle Redesigned Solid Rocket Motor (RSRM) metal parts. Small-scale testing demonstrated that the alkaline-based wash solution possesses adequate soil loading and cleaning properties. However, full-scale testing exhibited unexpected depletion of some primary components of the wash solution. Specifically, there was a significant decrease in the concentration of sodium metasilicate which forced change-out of the wash solution after eight days. Extension of wash solution bath life was necessary to ease the burden of frequent change-out on manufacturing. A laboratory study supports a depletion mechanism that is initiated by the hydrolysis of sodium tripolyphosphate (STPP) lowering the pH of the solution. The decrease in pH causes polymerization and subsequent precipitation of sodium metasilicate (SM). Further investigation showed that maintaining the pH was the key to preventing the precipitation of the sodium metasilicate. Implementation to the full scale operation demonstrated that periodic additions of potassium hydroxide (KOH) extended the useful bath life to more than four months.

  14. DEVELOPMENT, TESTING, AND DEMONSTRATION OF AN OPTIMAL FINE COAL CLEANING CIRCUIT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steven R. Hadley; R. Mike Mishra; Michael Placha

    1999-01-27

    The objective of this project was to improve the efficiency of the fine coal froth flotation circuit in commercial coal preparation plants. The plant selected for this project, Cyprus Emerald Coal Preparation Plant, cleans 1200-1400 tph of Pittsburgh seam raw coal and uses conventional flotation cells to clean the minus 100-mesh size fraction. The amount of coal in this size fraction is approximately 80 tph with an average ash content of 35%. The project was carried out in two phases. In Phase I, four advanced flotation cells, i.e., a Jameson cell, an Outokumpu HG tank cell, an open column, andmore » a packed column cell, were subjected to bench-scale testing and demonstration. In Phase II, two of these flotation cells, the Jameson cell and the packed column, were subjected to in-plant, proof-of-concept (POC) pilot plant testing both individually and in two-stage combination in order to ascertain whether a two-stage circuit results in lower levelized production costs. The bench-scale results indicated that the Jameson cell and packed column cell would be amenable to the single- and two-stage flotation approach. POC tests using these cells determined that single-stage coal matter recovery (CMR) of 85% was possible with a product ash content of 5.5-7%. Two-stage operation resulted in a coal recovery of 90% with a clean coal ash content of 6-7.5%. This compares favorably with the plant flotation circuit recovery of 80% at a clean coal ash of 11%.« less

  15. Bacterial contamination of stethoscopes on the intensive care unit.

    PubMed

    Whittington, A M; Whitlow, G; Hewson, D; Thomas, C; Brett, S J

    2009-06-01

    We assessed how often bedside stethoscopes in our intensive care unit were cleaned and whether they became colonised with potentially pathogenic bacteria. On two separate days the 12 nurses attending the bedspaces were questioned about frequency of stethoscope cleaning on the unit and the bedside stethoscopes were swabbed before and after cleaning to identify colonising organisms. Twenty-two health care providers entering the unit were asked the same questions and had their personal stethoscopes swabbed. All 32 non-medical staff cleaned their stethoscopes at least every day; however only three out of the 12 medical staff cleaned this often. Out of 24 intensive care unit bedside stethoscopes tested, two diaphragms and five earpieces were colonised with pathogenic bacteria. MRSA cultured from one earpiece persisted after cleaning. Three out of the 22 personal stethoscope diaphragms and five earpieces were colonised with pathogens. After cleaning, two diaphragms and two earpieces were still colonised, demonstrating the importance of regular cleaning.

  16. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    NASA Astrophysics Data System (ADS)

    Mirarchi, D.; Hall, G.; Redaelli, S.; Scandale, W.

    2017-06-01

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going.

  17. Enhanced Chemical Cleaning: A New Process for Chemically Cleaning Savannah River Waste Tanks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ketusky, Edward; Spires, Renee; Davis, Neil

    2009-02-11

    At the Savannah River Site (SRS) there are 49 High Level Waste (HLW) tanks that eventually must be emptied, cleaned, and closed. The current method of chemically cleaning SRS HLW tanks, commonly referred to as Bulk Oxalic Acid Cleaning (BOAC), requires about a half million liters (130,000 gallons) of 8 weight percent (wt%) oxalic acid to clean a single tank. During the cleaning, the oxalic acid acts as the solvent to digest sludge solids and insoluble salt solids, such that they can be suspended and pumped out of the tank. Because of the volume and concentration of acid used, amore » significant quantity of oxalate is added to the HLW process. This added oxalate significantly impacts downstream processing. In addition to the oxalate, the volume of liquid added competes for the limited available tank space. A search, therefore, was initiated for a new cleaning process. Using TRIZ (Teoriya Resheniya Izobretatelskikh Zadatch or roughly translated as the Theory of Inventive Problem Solving), Chemical Oxidation Reduction Decontamination with Ultraviolet Light (CORD-UV{reg_sign}), a mature technology used in the commercial nuclear power industry was identified as an alternate technology. Similar to BOAC, CORD-UV{reg_sign} also uses oxalic acid as the solvent to dissolve the metal (hydr)oxide solids. CORD-UV{reg_sign} is different, however, since it uses photo-oxidation (via peroxide/UV or ozone/UV to form hydroxyl radicals) to decompose the spent oxalate into carbon dioxide and water. Since the oxalate is decomposed and off-gassed, CORD-UV{reg_sign} would not have the negative downstream oxalate process impacts of BOAC. With the oxalate destruction occurring physically outside the HLW tank, re-precipitation and transfer of the solids, as well as regeneration of the cleaning solution can be performed without adding additional solids, or a significant volume of liquid to the process. With a draft of the pre-conceptual Enhanced Chemical Cleaning (ECC) flowsheet, taking full advantage of the many CORD-UV{reg_sign} benefits, performance demonstration testing was initiated using available SRS sludge simulant. The demonstration testing confirmed that ECC is a viable technology, as it can dissolve greater than 90% of the sludge simulant and destroy greater than 90% of the oxalates. Additional simulant and real waste testing are planned.« less

  18. Replacement of HCFC-225 Solvent for Cleaning NASA Propulsion Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.; Mitchell, Mark A.

    2015-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon-225 (HCFC-225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC-225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both NASA and the Defense Logistics Agency - Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC-225 that is both an effective cleaner and safe for use with oxygen systems. This presentation summarizes the tests performed, results, and lessons learned. It also demonstrates the benefits of cross-agency collaboration in a time of limited resources.

  19. Development of a filter regeneration system for advanced spacecraft fluid systems

    NASA Technical Reports Server (NTRS)

    Behrend, A. F., Jr.; Descamp, V. A.

    1974-01-01

    The development of a filter regeneration system for efficiently cleaning fluid particulate filters is presented. Based on a backflush/jet impingement technique, the regeneration system demonstrated a cleaning efficiency of 98.7 to 100%. The operating principles and design features are discussed with emphasis on the primary system components that include a regenerable filter, vortex particle separator, and zero-g particle trap. Techniques and equipment used for ground and zero-g performance tests are described. Test results and conclusions, as well as possible areas for commercial application, are included.

  20. The Sequential Probability Ratio Test: An efficient alternative to exact binomial testing for Clean Water Act 303(d) evaluation.

    PubMed

    Chen, Connie; Gribble, Matthew O; Bartroff, Jay; Bay, Steven M; Goldstein, Larry

    2017-05-01

    The United States's Clean Water Act stipulates in section 303(d) that states must identify impaired water bodies for which total maximum daily loads (TMDLs) of pollution inputs into water bodies are developed. Decision-making procedures about how to list, or delist, water bodies as impaired, or not, per Clean Water Act 303(d) differ across states. In states such as California, whether or not a particular monitoring sample suggests that water quality is impaired can be regarded as a binary outcome variable, and California's current regulatory framework invokes a version of the exact binomial test to consolidate evidence across samples and assess whether the overall water body complies with the Clean Water Act. Here, we contrast the performance of California's exact binomial test with one potential alternative, the Sequential Probability Ratio Test (SPRT). The SPRT uses a sequential testing framework, testing samples as they become available and evaluating evidence as it emerges, rather than measuring all the samples and calculating a test statistic at the end of the data collection process. Through simulations and theoretical derivations, we demonstrate that the SPRT on average requires fewer samples to be measured to have comparable Type I and Type II error rates as the current fixed-sample binomial test. Policymakers might consider efficient alternatives such as SPRT to current procedure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Evaluating and improving terminal hygiene practices on broiler farms to prevent Campylobacter cross-contamination between flocks.

    PubMed

    Battersby, Tara; Walsh, D; Whyte, P; Bolton, D

    2017-06-01

    The objectives of this study were to evaluate current cleaning practices in broiler houses by testing a range of sites after cleaning and disinfection and to test the efficacy of the most commonly used methods in a commercial broiler house after flock harvesting. Cleaning procedures on 20 broiler houses (10 separate farms) were examined by testing a range of sampling points (feeders, drinkers, walls, etc.) for total viable count (TVC), total Enterobacteriaceae count (TEC) and Campylobacter spp. after cleaning and disinfection, using culture based methods. In a second experiment, the six most commonly used commercially available disinfectants and/or detergent products were evaluated. The results of the first study demonstrated that critical areas in 12 of the 20 broiler houses were not effectively cleaned and disinfected between flocks as the tarmac apron, ante-room, house door, feeders, drinkers, walls, columns, barriers and/or bird weighs were Campylobacter positive. Thermal fogging with the combination of potassium peroxymonosulfate, sulfamic acid and sodium chloride (5%, v/v) or the glutaraldehyde and quaternary ammonium complex (0.3%, v/v) were the most effective treatments while other disinfectant treatments were considerably less effective. It was therefore concluded that farmers should review their broiler house cleaning and disinfection procedures if Campylobacter cross-contamination between successive flocks is to be prevented. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Clinical validation of robot simulation of toothbrushing - comparative plaque removal efficacy

    PubMed Central

    2014-01-01

    Background Clinical validation of laboratory toothbrushing tests has important advantages. It was, therefore, the aim to demonstrate correlation of tooth cleaning efficiency of a new robot brushing simulation technique with clinical plaque removal. Methods Clinical programme: 27 subjects received dental cleaning prior to 3-day-plaque-regrowth-interval. Plaque was stained, photographically documented and scored using planimetrical index. Subjects brushed teeth 33–47 with three techniques (horizontal, rotating, vertical), each for 20s buccally and for 20s orally in 3 consecutive intervals. The force was calibrated, the brushing technique was video supported. Two different brushes were randomly assigned to the subject. Robot programme: Clinical brushing programmes were transfered to a 6-axis-robot. Artificial teeth 33–47 were covered with plaque-simulating substrate. All brushing techniques were repeated 7 times, results were scored according to clinical planimetry. All data underwent statistical analysis by t-test, U-test and multivariate analysis. Results The individual clinical cleaning patterns are well reproduced by the robot programmes. Differences in plaque removal are statistically significant for the two brushes, reproduced in clinical and robot data. Multivariate analysis confirms the higher cleaning efficiency for anterior teeth and for the buccal sites. Conclusions The robot tooth brushing simulation programme showed good correlation with clinically standardized tooth brushing. This new robot brushing simulation programme can be used for rapid, reproducible laboratory testing of tooth cleaning. PMID:24996973

  3. Clinical validation of robot simulation of toothbrushing--comparative plaque removal efficacy.

    PubMed

    Lang, Tomas; Staufer, Sebastian; Jennes, Barbara; Gaengler, Peter

    2014-07-04

    Clinical validation of laboratory toothbrushing tests has important advantages. It was, therefore, the aim to demonstrate correlation of tooth cleaning efficiency of a new robot brushing simulation technique with clinical plaque removal. Clinical programme: 27 subjects received dental cleaning prior to 3-day-plaque-regrowth-interval. Plaque was stained, photographically documented and scored using planimetrical index. Subjects brushed teeth 33-47 with three techniques (horizontal, rotating, vertical), each for 20s buccally and for 20s orally in 3 consecutive intervals. The force was calibrated, the brushing technique was video supported. Two different brushes were randomly assigned to the subject. Robot programme: Clinical brushing programmes were transfered to a 6-axis-robot. Artificial teeth 33-47 were covered with plaque-simulating substrate. All brushing techniques were repeated 7 times, results were scored according to clinical planimetry. All data underwent statistical analysis by t-test, U-test and multivariate analysis. The individual clinical cleaning patterns are well reproduced by the robot programmes. Differences in plaque removal are statistically significant for the two brushes, reproduced in clinical and robot data. Multivariate analysis confirms the higher cleaning efficiency for anterior teeth and for the buccal sites. The robot tooth brushing simulation programme showed good correlation with clinically standardized tooth brushing.This new robot brushing simulation programme can be used for rapid, reproducible laboratory testing of tooth cleaning.

  4. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility.

    PubMed

    Santos-Junior, Aires G; Ferreira, Adriano M; Frota, Oleci P; Rigotti, Marcelo A; Barcelos, Larissa da S; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G; R Furlan, Mara C

    2018-01-01

    Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle ( p =0.007) and the toilet bowl ( p =0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect ( p =0.04). The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems.

  5. The Healy clean coal project: An overview

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olson, J.B.; McCrohan, D.V.

    1997-12-31

    The Healy Clean Coal Project, selected by the US Department of Energy under Round III of the Clean Coal Technology Program is currently in construction. The project is owned and financed by the Alaska Industrial Development and Export Authority (AIDEA), and is cofunded by the US Department of Energy. Construction is scheduled to be completed in August of 1997, with startup activity concluding in December of 1997. Demonstration, testing and reporting of the results will take place in 1998, followed by commercial operation of the facility. The emission levels of NOx, SO{sub 2} and particulates from this 50 megawatt plantmore » are expected to be significantly lower than current standards. The project status, its participants, a description of the technology to be demonstrated, and the operational and performance goals of this project are presented.« less

  6. INTEGRATED DEMONSTRATION OF SURFACTANT-ENHANCED AQUIFER REMEDIATION WITH SURFACTANT RECOVERY AND REUSE

    EPA Science Inventory

    The demonstration site will be the base dry cleaning facility at Camp Lejeune, North Carolina. Conservative and partitioning tracer tests will be used in conjunction with conventional core and ground-water sampling to characterize the site with respect to DNAPL composition and d...

  7. Development and Testing of Geo-Processing Models for the Automatic Generation of Remediation Plan and Navigation Data to Use in Industrial Disaster Remediation

    NASA Astrophysics Data System (ADS)

    Lucas, G.; Lénárt, C.; Solymosi, J.

    2015-08-01

    This paper introduces research done on the automatic preparation of remediation plans and navigation data for the precise guidance of heavy machinery in clean-up work after an industrial disaster. The input test data consists of a pollution extent shapefile derived from the processing of hyperspectral aerial survey data from the Kolontár red mud disaster. Three algorithms were developed and the respective scripts were written in Python. The first model aims at drawing a parcel clean-up plan. The model tests four different parcel orientations (0, 90, 45 and 135 degree) and keeps the plan where clean-up parcels are less numerous considering it is an optimal spatial configuration. The second model drifts the clean-up parcel of a work plan both vertically and horizontally following a grid pattern with sampling distance of a fifth of a parcel width and keep the most optimal drifted version; here also with the belief to reduce the final number of parcel features. The last model aims at drawing a navigation line in the middle of each clean-up parcel. The models work efficiently and achieve automatic optimized plan generation (parcels and navigation lines). Applying the first model we demonstrated that depending on the size and geometry of the features of the contaminated area layer, the number of clean-up parcels generated by the model varies in a range of 4% to 38% from plan to plan. Such a significant variation with the resulting feature numbers shows that the optimal orientation identification can result in saving work, time and money in remediation. The various tests demonstrated that the model gains efficiency when 1/ the individual features of contaminated area present a significant orientation with their geometry (features are long), 2/ the size of pollution extent features becomes closer to the size of the parcels (scale effect). The second model shows only 1% difference with the variation of feature number; so this last is less interesting for planning optimization applications. Last model rather simply fulfils the task it was designed for by drawing navigation lines.

  8. Clean Air Technology Initiative Projects

    EPA Pesticide Factsheets

    EPA Pacific Southwest has provided funding to both South Coast AQMD and San Joaquin Valley APCD to help spur early-stage, innovative technologies that need further testing and demonstration prior to deployment and commercialization.

  9. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility

    PubMed Central

    Santos-Junior, Aires G.; Ferreira, Adriano M.; Frota, Oleci P.; Rigotti, Marcelo A.; Barcelos, Larissa da S.; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G.; R. Furlan, Mara C.

    2018-01-01

    Background: Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. Aims: To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. Method: The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Results: Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle (p=0.007) and the toilet bowl (p=0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect (p=0.04). Conclusion: The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. Relevance to Clinical Practice: The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems. PMID:29643951

  10. Fabrication, test and demonstration of critical environment monitoring system

    NASA Technical Reports Server (NTRS)

    Heimendinger, K. W.

    1972-01-01

    Design and performance of an analytical system for the evaluation of certain environmental constituents in critical environmental areas of the Quality Reliability and Assurance Laboratory are reported. Developed was a self-contained, integrated, minimum sized unit that detects, interrogates, and records those parameters of the environment dictated for control in large storage facilities, clean rooms, temporarily curtained enclosures, and special working benches. The system analyzes humidity, temperature, hydrocarbons particle size, and particle count within prescribed clean areas.

  11. Cleaning verification by air/water impingement

    NASA Technical Reports Server (NTRS)

    Jones, Lisa L.; Littlefield, Maria D.; Melton, Gregory S.; Caimi, Raoul E. B.; Thaxton, Eric A.

    1995-01-01

    This paper will discuss how the Kennedy Space Center intends to perform precision cleaning verification by Air/Water Impingement in lieu of chlorofluorocarbon-113 gravimetric nonvolatile residue analysis (NVR). Test results will be given that demonstrate the effectiveness of the Air/Water system. A brief discussion of the Total Carbon method via the use of a high temperature combustion analyzer will also be given. The necessary equipment for impingement will be shown along with other possible applications of this technology.

  12. Healthcare Laundry and Textiles in the United States: Review and Commentary on Contemporary Infection Prevention Issues.

    PubMed

    Sehulster, Lynne M

    2015-09-01

    Healthcare professionals have questions about the infection prevention effectiveness of contemporary laundry processes for healthcare textiles (HCTs). Current industrial laundry processes achieve microbial reductions via physical, chemical, and thermal actions, all of which result in producing hygienically clean HCTs. European researchers have demonstrated that oxidative laundry additives have sufficient potency to meet US Environmental Protection Agency benchmarks for sanitizers and disinfectants. Outbreaks of infectious diseases associated with laundered HCTs are extremely rare; only 12 such outbreaks have been reported worldwide in the past 43 years. Root cause analyses have identified inadvertent exposure of clean HCTs to environmental contamination (including but not limited to exposure to dust in storage areas) or a process failure during laundering. To date, patient-to-patient transmission of infection has not been associated with hygienically clean HCTs laundered in accordance with industry process standards. Occupationally acquired infection involved mishandling of soiled HCTs and failure to use personal protective equipment properly. Laboratory studies of antimicrobial treatments for HCTs demonstrate a wide range of activity from 1 to 7 log10 reduction of pathogens under various experimental conditions. Clinical studies are needed to evaluate potential use of these treatments for infection prevention. Microbiological testing of clean HCTs for certification purposes is now available in the United States. Key features (eg, microbial sampling strategy, numbers of textiles sampled) and justification of the testing are discussed.

  13. 40 CFR 88.306-94 - Requirements for a converted vehicle to qualify as a clean-fuel fleet vehicle.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... exemption from the post-installation emission test requirements of paragraph (c) of this section. If granted...) Sufficient information to demonstrate that complying with the post-installation emission test requirement... are subject to the post-installation test requirement of paragraph (c)(2) of this section. (iii) If...

  14. Efficacy of sodium dodecyl sulphate and natural extracts against E. coli biofilm.

    PubMed

    Fink, Rok; Kulaš, Stefan; Oder, Martina

    2018-05-02

    The aim of this study was to determine and compare the efficacy of a standard cleaning agent, sodium dodecyl sulphate, and natural extracts from pomegranate peel grape skin and bay laurel leaf against E. coli biofilm. The biofilm was exposed for 10 minutes to three different concentrations of each tested compound. The results show that bay laurel leaf extract is the most efficient with 43% biofilm biomass reduction, followed by pomegranate peel extract (35%); sodium dodecyl sulphate and grape skin extract each have 30% efficacy. Our study demonstrated that natural extracts from selected plants have the same or even better efficacy against E. coli biofilm removal from surfaces than the tested classical cleaning agent do. All this indicates that natural plant extracts, which are acceptable from the health and environment points of view, can be potential substitutes for classical cleaning agents.

  15. Microgas dispersion for fine-coal cleaning. Technical progress report, March 1, 1981-August 31, 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, R.H.; Halsey, G.S.; Sebba, F.

    1981-01-01

    The results of the flotation tests conducted demonstrate that the use of fine colloidal gas aphrons (CGA) bubbles is beneficial for fine coal flotation. As demonstrated with the ultrafine coal sample, the froth products of CGA flotation are almost twice as clean as those of the conventional flotation tests at 70% yield. The kerosene consumption was considerably higher, however, both in conventional and in CGA flotation. Attempts were made to coat the CGA bubbles with a film of kerosene and use them for flotation, hoping that this would reduce the oil consumption. However, no positive results have yet been obtainedmore » with this process. Another problem associated with CGA flotation is that the ash content of the froth products is relatively high when using a stable CGA, such as that prepared with Dowfroth M150. On the other hand, when using an unstable CGA, as is the case with MIBC, low ash clean coal products can be obtained, but at the expense of the yield. Two approaches are being investigated to correct this problem. A considerable amount of effort has been made to determine the surface charge of the CGA.« less

  16. Enhanced Bioreclamation of Jet Fuels: A Full-Scale Test at Eglin AFB, Florida

    DTIC Science & Technology

    1989-09-01

    accelerated fuel degradation. To the authors’ knowledge , in the United States only one relatively undocumented attempt at nitrate utilization has...site demonstrations. To the authors’ knowledge . only the nitrate demonstrations previously discussed have been attempted to clean tip fuel...authors* knowledge -, enhanced bioreclamation is the only demonstrated technology for in situ treatment of hydrocarbons in deeper groundwaters. 5

  17. Validation of Alternative to Ozone-Depleting Chemicals Used in Oxygen Line Cleaning

    DTIC Science & Technology

    2006-07-01

    concentration in air purge stream is continuously below 600 ppm ASTM G88 Leak testing B-1B mock-up and actual 2.9 To be determined from system...to determine the effectiveness of the solvent: the solvent chosen, its concentration , and the shear stress exerted on the surface by the cleaning...operators must be trained in its use. 11 3.0 DEMONSTRATION DESIGN 3.1 PERFORMANCE OBJECTIVES The objective for this project was to produce a

  18. Coal cleaning: An underutilized solution?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Godfrey, R.L.

    1995-12-31

    Custom Coals Corporation is based in Pittsburgh, Pennsylvania. It is involved in the construction and operation of advanced coal cleaning facilities. The company has initially chosen to focus on Pennsylvania`s vast reserves of coal, because these coal provide a superior feedstock for the Technology. In a $76 million project co-sponsored by the U.S. Department of Energy, Custom Coals is constructing its first coal cleaning facility. The DOE chose to participate with the company in the project pursuant to a competition it sponsored under Round IV of Its Clean Cod Technology program. Thirty-one companies submitted 33 projects seeking approximately $2.3 billionmore » of funding against the $600 million available. The company`s project was one of nine proposals accepted and was the only pre-combustion cleaning technology awarded. The project includes both the construction of a 500 ton per hour coal cleaning facility utilizing the company`s proprietary technologies and a series of power plant test bums on a variety of U.S. coals during a 12-month demonstration program. Three U.S. coal seams - Sewickley, Lower Freeport and Illinois No. 5 - will supply the initial feedstock for the demonstration project. These seams represent a broad range of raw cod qualifies. The processed coals will then be distributed to a number of generating stations for combustion. The 300 megawatt Martins Creek Plant of Pennsylvania Power & Light Co., near Allentown, Pennsylvania, will burn Carefree Coal, the 60 megawatt Whitewater Valley Power Station of Richmond Power and Light (in Indiana) and the Ashtabula, Ohio unit of Centerior Energy will burn Self-Scrubbing Coal. Following these demonstrations, the plant will begin full-scale commercial operation, providing two million tons of Pennsylvania compliance coals to electric power utilities.« less

  19. Chiyoda Thoroughbred CT-121 clean coal project at Georgia Power`s Plant Yates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burford, D.P.

    1997-12-31

    The Chiyoda Thoroughbred CT-121 flue gas desulfurization (FGD) process at Georgia Power`s Plant Yates completed a two year demonstration of its capabilities in late 1994 under both high- and low-particulate loading conditions. This $43 million demonstration was co-funded by Southern Company, the Electric Power Research Institute and the DOE under the auspices of the US Department of Energy`s Round II Innovative Clean Coal Technology (ICCT) program. The focus of the Yates Project was to demonstrate several cost-saving modifications to Chiyoda`s already efficient CT-121 process. These modifications included: the extensive use of fiberglass reinforced plastics (FRP) in the construction of themore » scrubber vessel and other associated vessels, the elimination of flue gas reheat through the use of an FRP wet chimney, and reliable operation without a spare absorber module. This paper focuses on the testing results from the last trimester of the second phase of testing (high-ash loading). Specifically, operation under elevated ash loading conditions, the effects of low- and high-sulfur coal, air toxics verification testing results and unexpected improvements in byproduct gypsum quality are discussed.« less

  20. Efficacy of humidity retention bags for the reduced adsorption and improved cleaning of tissue proteins including prion-associated amyloid to surgical stainless steel surfaces.

    PubMed

    Secker, T J; Pinchin, H E; Hervé, R C; Keevil, C W

    2015-01-01

    Increasing drying time adversely affects attachment of tissue proteins and prion-associated amyloid to surgical stainless steel, and reduces the efficacy of commercial cleaning chemistries. This study tested the efficacy of commercial humidity retention bags to reduce biofouling on surgical stainless steel and to improve subsequent cleaning. Surgical stainless steel surfaces were contaminated with ME7-infected brain homogenates and left to dry for 15 to 1,440 min either in air, in dry polythene bags or within humidity retention bags. Residual contamination pre/post cleaning was analysed using Thioflavin T/SYPRO Ruby dual staining and microscope analysis. An increase in biofouling was observed with increased drying time in air or in sealed dry bags. Humidity retention bags kept both protein and prion-associated amyloid minimal across the drying times both pre- and post-cleaning. Therefore, humidity bags demonstrate a cheap, easy to implement solution to improve surgical instrument reprocessing and to potentially reduce associated hospital acquired infections.

  1. Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

    PubMed Central

    Rödiger, Matthias; Rinke, Sven; Ehret-Kleinau, Fenja; Pohlmeyer, Franziska; Lange, Katharina; Bürgers, Ralf

    2014-01-01

    PURPOSE To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: 5.7°; customized-long, height: 6.79 mm, taper: 4.8°; customized-short, height: 4.31 mm, taper: 4.8°) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: 5.7°) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting. PMID:25006388

  2. Quiet Clean Short-haul Experimental Engine (QCSEE). Under-The-Wing (UTW) engine boilerplate nacelle test report, volume 1

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The design and testing of high bypass geared turbofan engines with nacelles forming the propulsion systems for short haul passenger aircraft are considered. The test results demonstrate the technology required for externally blown flap aircraft for introduction into passenger service in the 1980's. The equipment tested is described along with the test facility and instrumentation. A chronological history of the test and a summary of results are given.

  3. Prediction of Protein-Protein Interaction Sites with Machine-Learning-Based Data-Cleaning and Post-Filtering Procedures.

    PubMed

    Liu, Guang-Hui; Shen, Hong-Bin; Yu, Dong-Jun

    2016-04-01

    Accurately predicting protein-protein interaction sites (PPIs) is currently a hot topic because it has been demonstrated to be very useful for understanding disease mechanisms and designing drugs. Machine-learning-based computational approaches have been broadly utilized and demonstrated to be useful for PPI prediction. However, directly applying traditional machine learning algorithms, which often assume that samples in different classes are balanced, often leads to poor performance because of the severe class imbalance that exists in the PPI prediction problem. In this study, we propose a novel method for improving PPI prediction performance by relieving the severity of class imbalance using a data-cleaning procedure and reducing predicted false positives with a post-filtering procedure: First, a machine-learning-based data-cleaning procedure is applied to remove those marginal targets, which may potentially have a negative effect on training a model with a clear classification boundary, from the majority samples to relieve the severity of class imbalance in the original training dataset; then, a prediction model is trained on the cleaned dataset; finally, an effective post-filtering procedure is further used to reduce potential false positive predictions. Stringent cross-validation and independent validation tests on benchmark datasets demonstrated the efficacy of the proposed method, which exhibits highly competitive performance compared with existing state-of-the-art sequence-based PPIs predictors and should supplement existing PPI prediction methods.

  4. CleanFleet final report. Volume 7, vehicle emissions

    DOT National Transportation Integrated Search

    1995-12-01

    CleanFleet, formally known as the South Coast Alternative Fuels Demonstration, : was a comprehensive demonstration of alternative fuel vehicles (AFVs) in daily : commercial service. Measurements of exhaust and evaporative emissions from CleanFleet va...

  5. A Test of Superradiance in an FEL Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyce, R

    We describe the design of an FEL Amplifier Test Experiment (FATE)1 to demonstrate the superradiant short bunch regime of a Free Electron Laser in the 1-3 {micro}m wavelength range starting from noise. The relevance to the LCLS X-ray FEL [1] proposal is discussed and numerical simulations are shown. It is numerically demonstrated for the first time with the 2-D code GINGER, that clean-up of noise in the superradiant regime occurs even at low power levels.

  6. ANNULUS CLOSURE TECHNOLOGY DEVELOPMENT INSPECTION/SALT DEPOSIT CLEANING MAGNETIC WALL CRAWLER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minichan, R; Russell Eibling, R; James Elder, J

    2008-06-01

    The Liquid Waste Technology Development organization is investigating technologies to support closure of radioactive waste tanks at the Savannah River Site (SRS). Tank closure includes removal of the wastes that have propagated to the tank annulus. Although amounts and types of residual waste materials in the annuli of SRS tanks vary, simple salt deposits are predominant on tanks with known leak sites. This task focused on developing and demonstrating a technology to inspect and spot clean salt deposits from the outer primary tank wall located in the annulus of an SRS Type I tank. The Robotics, Remote and Specialty Equipmentmore » (RRSE) and Materials Science and Technology (MS&T) Sections of the Savannah River National Laboratory (SRNL) collaborated to modify and equip a Force Institute magnetic wall crawler with the tools necessary to demonstrate the inspection and spot cleaning in a mock-up of a Type I tank annulus. A remote control camera arm and cleaning head were developed, fabricated and mounted on the crawler. The crawler was then tested and demonstrated on a salt simulant also developed in this task. The demonstration showed that the camera is capable of being deployed in all specified locations and provided the views needed for the planned inspection. It also showed that the salt simulant readily dissolves with water. The crawler features two different techniques for delivering water to dissolve the salt deposits. Both water spay nozzles were able to dissolve the simulated salt, one is more controllable and the other delivers a larger water volume. The cleaning head also includes a rotary brush to mechanically remove the simulated salt nodules in the event insoluble material is encountered. The rotary brush proved to be effective in removing the salt nodules, although some fine tuning may be required to achieve the best results. This report describes the design process for developing technology to add features to a commercial wall crawler and the results of the demonstration testing performed on the integrated system. The crawler was modified to address the two primary objectives of the task (inspection and spot cleaning). SRNL recommends this technology as a viable option for annulus inspection and salt removal in tanks with minimal salt deposits (such as Tanks 5 and 6.) This report further recommends that the technology be prepared for field deployment by: (1) developing an improved mounting system for the magnetic idler wheel, (2) improving the robustness of the cleaning tool mounting, (3) resolving the nozzle selection valve connections, (4) determining alternatives for the brush and bristle assembly, and (5) adding a protective housing around the motors to shield them from water splash. In addition, SRNL suggests further technology development to address annulus cleaning issues that are apparent on other tanks that will also require salt removal in the future such as: (1) Developing a duct drilling device to facilitate dissolving salt inside ventilation ducts and draining the solution out the bottom of the ducts. (2) Investigating technologies to inspect inside the vertical annulus ventilation duct.« less

  7. SPMHD simulations of structure formation

    NASA Astrophysics Data System (ADS)

    Barnes, David J.; On, Alvina Y. L.; Wu, Kinwah; Kawata, Daisuke

    2018-05-01

    The intracluster medium of galaxy clusters is permeated by μ {G} magnetic fields. Observations with current and future facilities have the potential to illuminate the role of these magnetic fields play in the astrophysical processes of galaxy clusters. To obtain a greater understanding of how the initial seed fields evolve to the magnetic fields in the intracluster medium requires magnetohydrodynamic simulations. We critically assess the current smoothed particle magnetohydrodynamic (SPMHD) schemes, especially highlighting the impact of a hyperbolic divergence cleaning scheme and artificial resistivity switch on the magnetic field evolution in cosmological simulations of the formation of a galaxy cluster using the N-body/SPMHD code GCMHD++. The impact and performance of the cleaning scheme and two different schemes for the artificial resistivity switch is demonstrated via idealized test cases and cosmological simulations. We demonstrate that the hyperbolic divergence cleaning scheme is effective at suppressing the growth of the numerical divergence error of the magnetic field and should be applied to any SPMHD simulation. Although the artificial resistivity is important in the strong field regime, it can suppress the growth of the magnetic field in the weak field regime, such as galaxy clusters. With sufficient resolution, simulations with divergence cleaning can reproduce observed magnetic fields. We conclude that the cleaning scheme alone is sufficient for galaxy cluster simulations, but our results indicate that the SPMHD scheme must be carefully chosen depending on the regime of the magnetic field.

  8. Novel denture-cleaning system based on hydroxyl radical disinfection.

    PubMed

    Kanno, Taro; Nakamura, Keisuke; Ikai, Hiroyo; Hayashi, Eisei; Shirato, Midori; Mokudai, Takayuki; Iwasawa, Atsuo; Niwano, Yoshimi; Kohno, Masahiro; Sasaki, Keiichi

    2012-01-01

    The purpose of this study was to evaluate a new denture-cleaning device using hydroxyl radicals generated from photolysis of hydrogen peroxide (H2O2). Electron spin resonance analysis demonstrated that the yield of hydroxyl radicals increased with the concentration of H2O2 and light irradiation time. Staphylococcus aureus, Pseudomonas aeruginosa, and methicillin-resistant S aureus were killed within 10 minutes with a > 5-log reduction when treated with photolysis of 500 mM H2O2; Candida albicans was killed within 30 minutes with a > 4-log reduction with photolysis of 1,000 mM H2O2. The clinical test demonstrated that the device could effectively reduce microorganisms in denture plaque by approximately 7-log order within 20 minutes.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craig N. Eatough

    In order to produce steel (a necessary commodity in developed nations) using conventional technologies, you must have metallurgical coke. Current coke-making technology pyrolyzes high-quality coking coals in a slot oven, but prime coking coals are becoming more expensive and slot ovens are being shut-down because of age and environmental problems. The United States typically imports about 4 million tons of coke per year, but because of a world-wide coke scarcity, metallurgical coke costs have risen from about $77 per tonne to more than $225. This coke shortage is a long-term challenge driving up the price of steel and is forcingmore » steel makers to search for alternatives. Combustion Resources (CR) has developed a technology to produce metallurgical coke from alternative feedstocks in an environmentally clean manner. The purpose of the current project was to refine material and process requirements in order to achieve improved economic benefits and to expand upon prior work on the proposed technology through successful prototype testing of coke products. The ultimate objective of this project is commercialization of the proposed technology. During this project period, CR developed coke from over thirty different formulations that meet the strength and reactivity requirements for use as metallurgical coke. The technology has been termed CR Clean Coke because it utilizes waste materials as feedstocks and is produced in a continuous process where pollutant emissions can be significantly reduced compared to current practice. The proposed feed material and operating costs for a CR Clean Coke plant are significantly less than conventional coke plants. Even the capital costs for the proposed coke plant are about half that of current plants. The remaining barrier for CR Clean Coke to overcome prior to commercialization is full-scale testing in a blast furnace. These tests will require a significant quantity of product (tens of thousands of tons) necessitating the construction of a demonstration facility. Talks are currently underway with potential partners and investors to build a demonstration facility that will generate enough coke for meaningful blast furnace evaluation tests. If the testing is successful, CR Clean Coke could potentially eliminate the need for the United States to import any coke, effectively decreasing US Steel industry dependence on foreign nations and reducing the price of domestic steel.« less

  10. Experimental investigation on cleaning of corroded ancient coins using a Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Zhu, Huazhong; Lu, Jian; Ni, Xiaowu; Shen, Zhonghua

    2017-05-01

    The objective of the work reported is to study experimentally on the removal of corrosion layer from the ancient coins using laser beam as the conservation tool. With the use of Q-switched Nd:YAG laser radiation at 1064 nm, dry laser cleaning, steam laser cleaning and chemical-assisted laser cleaning were used to find out a more suitable and efficient laser treatment for corrosion removal. Cleaning tests were performed on ancient Chinese coins. Experimental results shows that the dry laser cleaning was not successful at removing all types of corrosion crust. It was possible to remove the outer thicker layer of the corrosion products (typically known as patina), but failed on the thinner layer of cuprite. The steam laser cleaning could decrease the initial removal threshold and improve the removal efficiency especially for the oxidation with powdery structure. As for chemical-assisted laser treatment, the cleaning results demonstrate that the combination of laser and chemical reagent could provide a considerable improvement in corrosion removal compared with the conventional laser treatments. Most of the corrosion contaminant was stripped, even the cuprite layer. Moreover, no secondary pollution was formed on the cleaned surface. X-ray fluorescence was applied to determine the variation of composition of surface layer and bulk metal before and after the coins cleaned. It shows that all of the three laser treatments were efficient to reduce the chlorine concentration on the surface of the coins more than 75%.

  11. Closure Report for Corrective Action Unit 412: Clean Slate I Plutonium Dispersion (TTR) Tonopah Test Range, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick

    This Closure Report (CR) presents information supporting the clean closure of Corrective Action Unit (CAU) 412: Clean Slate I Plutonium Dispersion (TTR), located on the Tonopah Test Range, Nevada. CAU 412 consists of a release of radionuclides to the surrounding soil from a storage–transportation test conducted on May 25, 1963. Corrective action investigation (CAI) activities were performed in April and May 2015, as set forth in the Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 412: Clean Slate I Plutonium Dispersion (TTR), Tonopah Test Range, Nevada; and in accordance with the Soils Activity Quality Assurance Plan. Themore » purpose of the CAI was to fulfill data needs as defined during the data quality objectives process. The CAU 412 dataset of investigation results was evaluated based on a data quality assessment. This assessment demonstrated the dataset is complete and acceptable for use in fulfilling the data needs identified by the data quality objectives process. This CR provides documentation and justification for the clean closure of CAU 412 under the FFACO without further corrective action. This justification is based on historical knowledge of the site, previous site investigations, implementation of the 1997 interim corrective action, and the results of the CAI. The corrective action of clean closure was confirmed as appropriate for closure of CAU 412 based on achievement of the following closure objectives: Radiological contamination at the site is less than the final action level using the ground troops exposure scenario (i.e., the radiological dose is less than the final action level): Removable alpha contamination is less than the high contamination area criterion: No potential source material is present at the site, and any impacted soil associated with potential source material has been removed so that remaining soil contains contaminants at concentrations less than the final action levels: and There is sufficient information to characterize investigation and remediation waste for disposal.« less

  12. Development of Statistical Process Control Methodology for an Environmentally Compliant Surface Cleaning Process in a Bonding Laboratory

    NASA Technical Reports Server (NTRS)

    Hutchens, Dale E.; Doan, Patrick A.; Boothe, Richard E.

    1997-01-01

    Bonding labs at both MSFC and the northern Utah production plant prepare bond test specimens which simulate or witness the production of NASA's Reusable Solid Rocket Motor (RSRM). The current process for preparing the bonding surfaces employs 1,1,1-trichloroethane vapor degreasing, which simulates the current RSRM process. Government regulations (e.g., the 1990 Amendments to the Clean Air Act) have mandated a production phase-out of a number of ozone depleting compounds (ODC) including 1,1,1-trichloroethane. In order to comply with these regulations, the RSRM Program is qualifying a spray-in-air (SIA) precision cleaning process using Brulin 1990, an aqueous blend of surfactants. Accordingly, surface preparation prior to bonding process simulation test specimens must reflect the new production cleaning process. The Bonding Lab Statistical Process Control (SPC) program monitors the progress of the lab and its capabilities, as well as certifies the bonding technicians, by periodically preparing D6AC steel tensile adhesion panels with EA-91 3NA epoxy adhesive using a standardized process. SPC methods are then used to ensure the process is statistically in control, thus producing reliable data for bonding studies, and identify any problems which might develop. Since the specimen cleaning process is being changed, new SPC limits must be established. This report summarizes side-by-side testing of D6AC steel tensile adhesion witness panels and tapered double cantilevered beams (TDCBs) using both the current baseline vapor degreasing process and a lab-scale spray-in-air process. A Proceco 26 inches Typhoon dishwasher cleaned both tensile adhesion witness panels and TDCBs in a process which simulates the new production process. The tests were performed six times during 1995, subsequent statistical analysis of the data established new upper control limits (UCL) and lower control limits (LCL). The data also demonstrated that the new process was equivalent to the vapor degreasing process.

  13. A new hydrogen peroxide--based medical-device detergent with germicidal properties: comparison with enzymatic cleaners.

    PubMed

    Alfa, M J; Jackson, M

    2001-06-01

    The objective of this study was to evaluate the efficacy of the cleaning and bacterial killing ability of a new non-enzyme-based formulation (killing detergent solution [KDS]) compared with commercially available enzymatic detergents that included Metrizyme (Metrex Research Division of Sybron Canada Ltd. Morrisburg, Ontario) and Gzyme (Germiphene Corp, Brantford, Ontario). KDS is a hydrogen peroxide-based detergent formulation that combines cleaning efficacy with the ability to kill microorganisms. The KDS formulation helps ensure the protection of the health care worker from infectious risk during the soaking and cleaning stages of medical device reprocessing and reduces the bioburden on devices before sterilization/disinfection. Test organisms that included Enterococcus faecalis, Salmonella choleraesuis, Staphylococcus aureus, and Pseudomonas aeruginosa were suspended in artificial test soil (ATS-B; patent submitted), inoculated at 10(6) colonyforming units per carrier and dried overnight before detergent exposure. The ATS-B mimics the blood, protein, carbohydrate, and endotoxin levels of patient-used medical devices. Plastic lumen carriers and a flexible colonoscope were used for surface and simulated-use testing, respectively. The results for the microbial challenge dried onto polyvinyl chloride (PVC) carriers demonstrated that the ability of KDS to remove protein, blood, carbohydrate, and endotoxin from surface test carriers was as effective as the enzyme detergents that were evaluated. Furthermore, KDS was able to effect approximately a 5-Log(10) reduction in microbial loads with a 3-minute exposure at room temperature, whereas none of the other detergents were as effective. In simulated-use testing of a soiled colonoscope, KDS was significantly better at ensuring microbial killing compared with Gzyme and Metrizyme and was equivalent to the enzymatic detergents in cleaning ability. In summary the KDS has excellent microbial-killing ability in 3-minute exposures at room temperature and cleans as well as the existing enzymatic detergent formulations that were tested.

  14. Enzymatic detergent formulation containing amylase from Aspergillus niger: a comparative study with commercial detergent formulations.

    PubMed

    Mitidieri, Sydnei; Souza Martinelli, Anne Helene; Schrank, Augusto; Vainstein, Marilene Henning

    2006-07-01

    There is a wide range of biotechnological applications for amylases, including the textile, pharmaceutical, food and laundry industries. Hydrolytic enzymes are 100% biodegradable and enzymatic detergents can achieve effective cleaning with lukewarm water. Microorganisms and culture media were tested for amylase production and the best producer was Aspergillus niger L119 (3.9 U ml(-1) +/- 0.2) in submerged culture and its amylase demonstrated excellent activity at 50-55 degrees C and pH 4.0, remaining stable at 53 degrees C for up to 200 h. In order to establish the potential uses of this enzyme in detergents, different formulations were tested using the A. niger amylase extract. Enzyme activity was compared with three commercial formulations. The detergents are used in hospitals to clean surgical and endoscopy equipment. The presence of amylase in the formulation is because of its action within hospital drainage system, whether or not it has any function in cleaning the equipment.

  15. An improved method for polarimetric image restoration in interferometry

    NASA Astrophysics Data System (ADS)

    Pratley, Luke; Johnston-Hollitt, Melanie

    2016-11-01

    Interferometric radio astronomy data require the effects of limited coverage in the Fourier plane to be accounted for via a deconvolution process. For the last 40 years this process, known as `cleaning', has been performed almost exclusively on all Stokes parameters individually as if they were independent scalar images. However, here we demonstrate for the case of the linear polarization P, this approach fails to properly account for the complex vector nature resulting in a process which is dependent on the axes under which the deconvolution is performed. We present here an improved method, `Generalized Complex CLEAN', which properly accounts for the complex vector nature of polarized emission and is invariant under rotations of the deconvolution axes. We use two Australia Telescope Compact Array data sets to test standard and complex CLEAN versions of the Högbom and SDI (Steer-Dwedney-Ito) CLEAN algorithms. We show that in general the complex CLEAN version of each algorithm produces more accurate clean components with fewer spurious detections and lower computation cost due to reduced iterations than the current methods. In particular, we find that the complex SDI CLEAN produces the best results for diffuse polarized sources as compared with standard CLEAN algorithms and other complex CLEAN algorithms. Given the move to wide-field, high-resolution polarimetric imaging with future telescopes such as the Square Kilometre Array, we suggest that Generalized Complex CLEAN should be adopted as the deconvolution method for all future polarimetric surveys and in particular that the complex version of an SDI CLEAN should be used.

  16. Wideband RELAX and wideband CLEAN for aeroacoustic imaging

    NASA Astrophysics Data System (ADS)

    Wang, Yanwei; Li, Jian; Stoica, Petre; Sheplak, Mark; Nishida, Toshikazu

    2004-02-01

    Microphone arrays can be used for acoustic source localization and characterization in wind tunnel testing. In this paper, the wideband RELAX (WB-RELAX) and the wideband CLEAN (WB-CLEAN) algorithms are presented for aeroacoustic imaging using an acoustic array. WB-RELAX is a parametric approach that can be used efficiently for point source imaging without the sidelobe problems suffered by the delay-and-sum beamforming approaches. WB-CLEAN does not have sidelobe problems either, but it behaves more like a nonparametric approach and can be used for both point source and distributed source imaging. Moreover, neither of the algorithms suffers from the severe performance degradations encountered by the adaptive beamforming methods when the number of snapshots is small and/or the sources are highly correlated or coherent with each other. A two-step optimization procedure is used to implement the WB-RELAX and WB-CLEAN algorithms efficiently. The performance of WB-RELAX and WB-CLEAN is demonstrated by applying them to measured data obtained at the NASA Langley Quiet Flow Facility using a small aperture directional array (SADA). Somewhat surprisingly, using these approaches, not only were the parameters of the dominant source accurately determined, but a highly correlated multipath of the dominant source was also discovered.

  17. Wideband RELAX and wideband CLEAN for aeroacoustic imaging.

    PubMed

    Wang, Yanwei; Li, Jian; Stoica, Petre; Sheplak, Mark; Nishida, Toshikazu

    2004-02-01

    Microphone arrays can be used for acoustic source localization and characterization in wind tunnel testing. In this paper, the wideband RELAX (WB-RELAX) and the wideband CLEAN (WB-CLEAN) algorithms are presented for aeroacoustic imaging using an acoustic array. WB-RELAX is a parametric approach that can be used efficiently for point source imaging without the sidelobe problems suffered by the delay-and-sum beamforming approaches. WB-CLEAN does not have sidelobe problems either, but it behaves more like a nonparametric approach and can be used for both point source and distributed source imaging. Moreover, neither of the algorithms suffers from the severe performance degradations encountered by the adaptive beamforming methods when the number of snapshots is small and/or the sources are highly correlated or coherent with each other. A two-step optimization procedure is used to implement the WB-RELAX and WB-CLEAN algorithms efficiently. The performance of WB-RELAX and WB-CLEAN is demonstrated by applying them to measured data obtained at the NASA Langley Quiet Flow Facility using a small aperture directional array (SADA). Somewhat surprisingly, using these approaches, not only were the parameters of the dominant source accurately determined, but a highly correlated multipath of the dominant source was also discovered.

  18. In situ oxygen plasma cleaning of microswitch surfaces—comparison of Ti and graphite electrodes

    NASA Astrophysics Data System (ADS)

    Oh, Changho; Streller, Frank; Ashurst, W. Robert; Carpick, Robert W.; de Boer, Maarten P.

    2016-11-01

    Ohmic micro- and nanoswitches are of interest for a wide variety of applications including radio frequency communications and as low power complements to transistors. In these switches, it is of paramount importance to maintain surface cleanliness in order to prevent frequent failure by tribopolymer growth. To prepare surfaces, an oxygen plasma clean is expected to be beneficial compared to a high temperature vacuum bakeout because of shorter cleaning time (<5 min compared to ~24 h) and active removal of organic contaminants. We demonstrate that sputtering of the electrode material during oxygen plasma cleaning is a critical consideration for effective cleaning of switch surfaces. With Ti electrodes, a TiO x layer forms that increases electrical contact resistance. When plasma-cleaned using graphite electrodes, the resistance of Pt-coated microswitches exhibit a long lifetime with consistently low resistance (<0.5 Ω variation over 300 million cycles) if the test chamber is refilled with ultra-high purity nitrogen and if the devices are not exposed to laboratory air. Their current-voltage characteristic is also linear at the millivolt level. This is important for nanoswitches which will be operated in that range.

  19. Multibar sawless lint cleaner: Field testing results

    USDA-ARS?s Scientific Manuscript database

    The Multibar Sawless Lint Cleaner (MBSLC) is a prototype spiked-tooth lint cleaner initially designed to replace the first stage lint cleaning in a cotton gin. Previous studies conducted in the ginning laboratory in Lubbock, Texas, demonstrated improvements in some fiber properties, as well as minim...

  20. Evaluation and remediation of bulk soap dispensers for biofilm.

    PubMed

    Lorenz, Lindsey A; Ramsay, Bradley D; Goeres, Darla M; Fields, Matthew W; Zapka, Carrie A; Macinga, David R

    2012-01-01

    Recent studies evaluating bulk soap in public restroom soap dispensers have demonstrated up to 25% of open refillable bulk-soap dispensers were contaminated with ~ 6 log(10)(CFU ml(-1)) heterotrophic bacteria. In this study, plastic counter-mounted, plastic wall-mounted and stainless steel wall-mounted dispensers were analyzed for suspended and biofilm bacteria using total cell and viable plate counts. Independent of dispenser type or construction material, the bulk soap was contaminated with 4-7 log(10)(CFU ml(-1)) bacteria, while 4-6 log(10)(CFU cm(-2)) biofilm bacteria were isolated from the inside surfaces of the dispensers (n = 6). Dispenser remediation studies, including a 10 min soak with 5000 mg l(-1) sodium hypochlorite, were then conducted to determine the efficacy of cleaning and disinfectant procedures against established biofilms. The testing showed that contamination of the bulk soap returned to pre-test levels within 7-14 days. These results demonstrate biofilm is present in contaminated bulk-soap dispensers and remediation studies to clean and sanitize the dispensers are temporary.

  1. Effect of mechanical cleaning with granular material on the permeability of submerged membranes in the MBR process.

    PubMed

    Siembida, B; Cornel, P; Krause, S; Zimmermann, B

    2010-07-01

    The research on fouling reduction and permeability loss in membrane bioreactors (MBRs) was carried out at two MBR pilot plants with synthetic and real wastewater. On the one hand, the effect of mechanical cleaning with an abrasive granular material on the performance of a submerged MBR process was tested. Additionally, scanning electron microscopy (SEM) measurements and integrity tests were conducted to check whether the membrane material was damaged by the granulate.The results indicate that the fouling layer formation was significantly reduced by abrasion using the granular material. This technique allowed a long-term operation of more than 600 days at a flux up to 40 L/(m2 h) without chemical cleaning of the membranes. Moreover, it was demonstrated that the membrane bioreactor (MBR) with granulate could be operated with more than 20% higher flux compared to a conventional MBR operation. SEM images and integrity tests showed that in consequence of abrasive cleaning, the granular material left brush marks on the membrane surface, however, the membrane function was not affected.In a parallel experimental set up, the impact of the operationally defined "truly soluble fraction" <0.04 microm from wastewater and activated sludge on the ultrafiltration membrane fouling characteristics was investigated. It was shown that the permeability loss was caused predominantly by the colloidal fraction >0.04 microm rather than by the dissolved fraction of wastewater and activated sludge.

  2. Demonstration of Mer-Cure Technology for Enhanced Mercury Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John Marion; Dave O'Neill; Kevin Taugher

    2008-06-01

    Alstom Power Inc. has completed a DOE/NETL-sponsored program (under DOE Cooperative Agreement No. De-FC26-07NT42776) to demonstrate Mer-Cure{trademark}, one of Alstom's mercury control technologies for coal-fired boilers. The Mer-Cure{trademark}system utilizes a small amount of Mer-Clean{trademark} sorbent that is injected into the flue gas stream for oxidation and adsorption of gaseous mercury. Mer-Clean{trademark} sorbents are carbon-based and prepared with chemical additives that promote oxidation and capture of mercury. The Mer-Cure{trademark} system is unique in that the sorbent is injected into an environment where the mercury capture kinetics is accelerated. The full-scale demonstration program originally included test campaigns at two host sites: LCRA's 480-MW{sub e} Fayette Unit No.3 and Reliant Energy's 190-MW{sub e} Shawville Unit No.3. The only demonstration tests actually done were the short-term tests at LCRA due to budget constraints. This report gives a summary of the demonstration testing at Fayette Unit No.3. The goals for this Mercury Round 3 program, established by DOE/NETL under the original solicitation, were to reduce the uncontrolled mercury emissions by 90% at a cost significantly less than 50% of the previous target ofmore » $$60,000/lb mercury removed. The results indicated that Mer-Cure{trademark} technology could achieve mercury removal of 90% based on uncontrolled stack emissions. The estimated costs for 90% mercury control, at a sorbent cost of $$0.75 to $2.00/lb respectively, were $13,400 to $18,700/lb Hg removed. In summary, the results from demonstration testing show that the goals established by DOE/NETL were met during this test program. The goal of 90% mercury reduction was achieved. Estimated mercury removal costs were 69-78% lower than the benchmark of $60,000/lb mercury removed, significantly less than 50% of the baseline removal cost.« less

  3. Removal of graffiti paintings from the Mansion de Mattis site in Corato (Bari), Italy: Laser deveiling or complete cleaning?

    NASA Astrophysics Data System (ADS)

    Daurelio, G.; Andriani, E. S.; Albanese, A.; Catalano, I. M.; Teseo, G.; Marano, D.

    2008-10-01

    Nowadays one the main problem of stone monuments conservation is not only the natural environment deterioration but the defaced, in particular esthetic, due to graffiti. This paper presents the different stages of the cleaning graffiti research: the laboratory study phase, in which the aims were to investigate the laser cleaning effect on substrate and testing user-friendly and efficient solutions for in situ application; the application phase in which the study results were applied in the restoration of Palazzo de Mattis facade. The graffiti cleaning were carried out by using a Q-Switch Nd:YAG laser source (λ=1064 nm with pulse duration, t=8 ns, f=2 to 20 Hz, energy per impulse up to 280 mJ) in dry, wet and Very wet modes adopting the Daurelio technique n.1 (blade spot laser). The Q-Switch Nd:Yag laser source has demonstrated to be the most suitable for a fully or, according to new restoring theory, "de veiling" graffiti ablation.

  4. Tooth Surface Comparison after Air Polishing and Rubber Cup: A Scanning Electron Microscopy Study.

    PubMed

    Camboni, Sara; Donnet, Marcel

    2016-03-01

    To demonstrate, using microscopic observations, the difference between two well-known oral prophylaxis techniques: polishing paste and air polishing. The observations were performed on human enamel. Enamel samples were obtained from plaque-rich human teeth extracted for orthodontic or clinical purposes. In order to allow a reliable comparison between different applications, each enamel sample was divided into two parts: one underwent air-polishing, whereas polishing paste was applied to the other. AIR-FLOW® Master was selected together with AIR-FLOW® PLUS for the prophylaxis powder application. For the polishing-paste application, several different pastes where used, including Cleanic®, CCS®, Proxyt®, and SuperPolish. A comparative test control was also used by cleaning the enamel with sodium hypochlorite (6%). The enamel treated with AIR-FLOW PLUS showed a similar surface when compared to the control enamel; however, there was complete cleaning down to the tooth microstructure. On the other hand, use of the polishing paste resulted in an enamel surface that appeared abraded and flattened. Moreover, some of the natural irregular enamel surfaces demonstrated some filling in with debris. AIR-FLOW PLUS powder was able to more deeply clean without creating any damage to the enamel, making it suitable for regular cleaning treatments. The polishing pastes were found to abrade the enamel surface, to flatten it, and deposit debris into the microcavities. Both methods having different mechanical effects can therefore be considered as complementary, in that some patients experience a sense of "roughness" following a cleaning. A clinical recommendation for this experience would be to use the air polish first to clean the enamel surface, and follow with a little polishing paste to smooth the surface, if required.

  5. The demonstration of an advanced cyclone coal combustor, with internal sulfur, nitrogen, and ash control for the conversion of a 23 MMBTU/hour oil fired boiler to pulverized coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zauderer, B.; Fleming, E.S.

    1991-08-30

    This work contains to the final report of the demonstration of an advanced cyclone coal combustor. Titles include: Chronological Description of the Clean Coal Project Tests,'' Statistical Analysis of Operating Data for the Coal Tech Combustor,'' Photographic History of the Project,'' Results of Slag Analysis by PA DER Module 1 Procedure,'' Properties of the Coals Limestone Used in the Test Effort,'' Results of the Solid Waste Sampling Performed on the Coal Tech Combustor by an Independent Contractor During the February 1990 Tests.'' (VC)

  6. Control of cavitation using dissolved carbon dioxide for damage-free megasonic cleaning of wafers

    NASA Astrophysics Data System (ADS)

    Kumari, Sangita

    This dissertation describes the finding that dissolved carbon dioxide is a potent inhibitor of sonoluminescence and describes the implications of the finding in the development of improved megasonic cleaning formulations. Megasonic cleaning, or the removal of contaminants particles from wafer surfaces using sound-irradiated cleaning fluids, has been traditionally used in the semiconductor industry for cleaning of wafers. A critical challenge in the field is to achieve removal of small particles (22 nm to 200 nm) without causing damage to fine wafer features. The work described here addresses this challenge by identifying sonoluminescence and solution pH as two key factors affecting damage and cleaning efficiency, respectively and establishing novel means to control them using CO2(aq) release compounds in the presence of acids and bases. Sonoluminescence (SL) behavior of the major dissolved gases such as Ar, Air, N2, O2 and CO2 was determined using a newly designed Cavitation Threshold Cell (CT Cell). SL, which is the phenomenon of release of light in sound-irradiated liquids, is a sensitive indicator of cavitation, primarily transient cavitation. It was found that all the tested dissolved gases such as Ar, Air, N2 and O2, generated SL signal efficiently. However, dissolved CO2 was found to be completely incapable of generating SL signal. Based on this interesting result, gradual suppression of SL signal was demonstrated using CO2(aq). It was further demonstrated that CO2(aq) is not only incapable but is also a potent inhibitor of SL. The inhibitory role of CO2(aq) was established using a novel method of controlled in-situ release of CO 2 from NH4HCO3. ~130 ppm CO2(aq) was shown to be necessary and sufficient for complete suppression of SL generation in air saturated DI water. The method however required acidification of solution for significant release of CO2, making it unsuitable for the design of cleaning solutions at high pH. Analysis of the underlying ionic equilibria revealed that the loss of released CO2(aq) upon increase in pH can be compensated by moderate increase in added NH4HCO3. Using this method, simultaneous control of SL and solution pH was demonstrated in two systems, NH4HCO3/HCl and NH4OH/CO2, at two nominal pH values; 5.7 and 7.0. Damage studies were performed on wafer samples with line/space patterns donated by IMEC and FSI International bearing Si/metal/a-Si gate stacks of thickness ~36 nm and Si/Poly-Si gate stacks of thickness ~67 nm, respectively. A single wafer spin cleaning tool MegPieRTM was used for the generation of megasonic energy for inducing damage to the structures. It was demonstrated that CO2 dissolution in DI water suppresses damage to the gate stacks in a dose-dependent manner. Together, these studies establish a systematic and strong correlation between CO2(aq) concentration, SL suppression and damage suppression. Significant damage reduction (~50 % to ~90 %) was observed at [CO2(aq)] > ~300 ppm. It was also demonstrated that CO2(aq) suppresses damage under alkaline pH condition too. This demonstration was made possible by the successful design of two new cleaning systems NH4HCO3/NH4OH and CO2/NH 4OH that could generate CO2(aq) under alkaline conditions. Damage suppressing ability of the newly designed cleaning systems were compared to the standard cleaning system NH4OH at pH 8.2 and it was found that NH4HCO3/NH4OH and CO2/NH 4OH systems were 80 % more efficient in suppressing damage compared to the standard NH4OH cleaning system. Finally, megasonic cleaning studies were conducted in the same single wafer spin cleaning tool MegPieRTM, using SiO2 particles (size 185 nm) deposited on 200 mm oxide Si wafers, as the contaminant. It was found that the standard cleaning chemical, NH4OH, pH 8.2, was effective in achieving > 95 % particle removal for 2 min irradiation of megasonic energy at power densities > 0.7 W/cm2. Based on these results, a new system, NH4HCO3/NH4OH, was designed with an aim to release ~300 ppm CO2 at pH 8.2. It was demonstrated that newly designed system NH4HCO3/NH 4OH, allowed significant suppression of damage in comparison to NH 4OH while maintaining > 90 % cleaning efficiency that was comparable to NH4OH solution, at the same acoustic power densities. Taken together, these studies establish a potent and flexible means for the inhibition of SL generation over a wide pH range and acoustic power densities and demonstrate its use in suppression of wafer damage without compromising megasonic cleaning efficiency. (Abstract shortened by UMI.)

  7. 40 CFR 63.5755 - How do I demonstrate compliance with the aluminum recreational boat surface coating spray gun...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the aluminum recreational boat surface coating spray gun cleaning work practice standards? 63.5755... recreational boat surface coating spray gun cleaning work practice standards? You must demonstrate compliance with the aluminum coating spray gun cleaning work practice standards by meeting the requirements of...

  8. 40 CFR 63.5755 - How do I demonstrate compliance with the aluminum recreational boat surface coating spray gun...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the aluminum recreational boat surface coating spray gun cleaning work practice standards? 63.5755... recreational boat surface coating spray gun cleaning work practice standards? You must demonstrate compliance with the aluminum coating spray gun cleaning work practice standards by meeting the requirements of...

  9. 40 CFR 63.5755 - How do I demonstrate compliance with the aluminum recreational boat surface coating spray gun...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the aluminum recreational boat surface coating spray gun cleaning work practice standards? 63.5755... recreational boat surface coating spray gun cleaning work practice standards? You must demonstrate compliance with the aluminum coating spray gun cleaning work practice standards by meeting the requirements of...

  10. 40 CFR 63.5755 - How do I demonstrate compliance with the aluminum recreational boat surface coating spray gun...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the aluminum recreational boat surface coating spray gun cleaning work practice standards? 63.5755... surface coating spray gun cleaning work practice standards? You must demonstrate compliance with the aluminum coating spray gun cleaning work practice standards by meeting the requirements of paragraph (a) or...

  11. 40 CFR 63.5755 - How do I demonstrate compliance with the aluminum recreational boat surface coating spray gun...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the aluminum recreational boat surface coating spray gun cleaning work practice standards? 63.5755... surface coating spray gun cleaning work practice standards? You must demonstrate compliance with the aluminum coating spray gun cleaning work practice standards by meeting the requirements of paragraph (a) or...

  12. Testing antimicrobial cleaner efficacy on gypsum wallboard contaminated with Stachybotrys chartarum.

    PubMed

    Menetrez, Marc Y; Foarde, Karin K; Webber, Tricia D; Dean, Timothy R; Betancourt, Doris A

    2007-11-01

    Reducing occupant exposure to indoor mold is the goal of this research, through the efficacy testing of antimicrobial cleaners. Often mold contaminated building materials are not properly removed, but instead surface cleaners are applied in an attempt to alleviate the problem. The efficacy of antimicrobial cleaners to remove, eliminate or control mold growth on surfaces can easily be tested on non-porous surfaces. However, the testing of antimicrobial cleaner efficacy on porous surfaces, such as those found in the indoor environment such as gypsum board can be more complicated and prone to incorrect conclusions regarding residual organisms. The mold Stachybotrys chartarum has been found to be associated with idiopathic pulmonary hemorrhage in infants and has been studied for toxin production and its occurrence in water damaged buildings. Growth of S. chartarum on building materials such as gypsum wallboard has been frequently documented. Research to control S. chartarum growth using 13 separate antimicrobial cleaners on contaminated gypsum wallboard has been performed in laboratory testing. Popular brands of cleaning products were tested by following directions printed on the product packaging. A variety of gypsum wallboard surfaces were used to test these cleaning products at high relative humidity. The results indicate differences in antimicrobial efficacy for the six month period of testing. Results for the six types of GWB surfaces varied extensively. However, three cleaning products exhibited significantly better results than others. Lysol All-Purpose Cleaner-Orange Breeze (full strength) demonstrated results which ranked among the best in five of the six surfaces tested. Both Borax and Orange Glo Multipurpose Degreaser demonstrated results which ranked among the best in four of the six surfaces tested. The best antimicrobial cleaner to choose is often dependent on the type of surface to be cleaned of S. chartarum contamination. For Plain GWB, no paint, the best cleaners were Borax, Lysol All-Purpose Cleaner-Orange Breeze (full strength), Orange Glo Multipurpose Degreaser, and Fantastik Orange Action. These results are not meant to endorse the incomplete removal of mold contaminated building materials. However, it is recognized that complete removal may not always be possible and solutions to control mold regrowth may contribute to reduced occupant exposure. Current recommendations of removal and replacement of porous building materials should be followed. It is not the intension of this discussion to endorse any product. Reporting on the performance of these products under the stated conditions was and remains the only purpose.

  13. Plasma cleaning of ITER first mirrors

    NASA Astrophysics Data System (ADS)

    Moser, L.; Marot, L.; Steiner, R.; Reichle, R.; Leipold, F.; Vorpahl, C.; Le Guern, F.; Walach, U.; Alberti, S.; Furno, I.; Yan, R.; Peng, J.; Ben Yaala, M.; Meyer, E.

    2017-12-01

    Nuclear fusion is an extremely attractive option for future generations to compete with the strong increase in energy consumption. Proper control of the fusion plasma is mandatory to reach the ambitious objectives set while preserving the machine’s integrity, which requests a large number of plasma diagnostic systems. Due to the large neutron flux expected in the International Thermonuclear Experimental Reactor (ITER), regular windows or fibre optics are unusable and were replaced by so-called metallic first mirrors (FMs) embedded in the neutron shielding, forming an optical labyrinth. Materials eroded from the first wall reactor through physical or chemical sputtering will migrate and will be deposited onto mirrors. Mirrors subject to net deposition will suffer from reflectivity losses due to the deposition of impurities. Cleaning systems of metallic FMs are required in more than 20 optical diagnostic systems in ITER. Plasma cleaning using radio frequency (RF) generated plasmas is currently being considered the most promising in situ cleaning technique. An update of recent results obtained with this technique will be presented. These include the demonstration of cleaning of several deposit types (beryllium, tungsten and beryllium proxy, i.e. aluminium) at 13.56 or 60 MHz as well as large scale cleaning (mirror size: 200 × 300 mm2). Tests under a strong magnetic field up to 3.5 T in laboratory and first experiments of RF plasma cleaning in EAST tokamak will also be discussed. A specific focus will be given on repetitive cleaning experiments performed on several FM material candidates.

  14. A surfactant free preparation of ultradispersed surface-clean Pt catalyst with highly stable electrocatalytic performance

    NASA Astrophysics Data System (ADS)

    Tao, Lu; Zhao, Yueping; Zhao, Yufeng; Huang, Shifei; Yang, Yunxia; Tong, Qi; Gao, Faming

    2018-02-01

    High efficiency platinum-based catalyst demands the ultrafine size and well dispersion of Pt nanoparticles (NPs), with clean surface and strong interactions between the supports. In this work, we demonstrate a simple strategy for the preparation of ultra-dispersed surface-clean Pt catalyst with high stability, in which the Pt nanoparticles (NPs) with 1.8 ± 0.6 nm in size are anchored tightly on a 3D hierarchical porous graphitized carbon (3D-HPG) through galvanic replacement reaction. The as-obtained catalyst can undergo 2000 voltage cycles with negligible activity decay and no apparent structure and size changes for MOR during the durability test, and its mass activity for ORR only reduce 18.3% after 5000 cycles. The excellent performance is attributed to strong anchoring effect between carbon support and Pt nanoparticles.

  15. Cleaning efficiency enhancement by ultrasounds for membranes used in dairy industries.

    PubMed

    Luján-Facundo, M J; Mendoza-Roca, J A; Cuartas-Uribe, B; Álvarez-Blanco, S

    2016-11-01

    Membrane cleaning is a key point for the implementation of membrane technologies in the dairy industry for proteins concentration. In this study, four ultrafiltration (UF) membranes with different molecular weight cut-offs (MWCOs) (5, 15, 30 and 50kDa) and materials (polyethersulfone and ceramics) were fouled with three different whey model solutions: bovine serum albumin (BSA), BSA plus CaCl2 and whey protein concentrate solution (Renylat 45). The purpose of the study was to evaluate the effect of ultrasounds (US) on the membrane cleaning efficiency. The influence of ultrasonic frequency and the US application modes (submerging the membrane module inside the US bath or applying US to the cleaning solution) were also evaluated. The experiments were performed in a laboratory plant which included the US equipment and the possibility of using two membrane modules (flat sheet and tubular). The fouling solution that caused the highest fouling degree for all the membranes was Renylat 45. Results demonstrated that membrane cleaning with US was effective and this effectiveness increased at lower frequencies. Although no significant differences were observed between the two different US applications modes tested, slightly higher cleaning efficiencies values placing the membrane module at the bottom of the tank were achieved. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Evaluating the use of laser radiation in cleaning of copper embroidery threads on archaeological Egyptian textiles

    NASA Astrophysics Data System (ADS)

    Abdel-Kareem, Omar; Harith, M. A.

    2008-07-01

    Cleaning of copper embroidery threads on archaeological textiles is still a complicated conservation process, as most textile conservators believe that the advantages of using traditional cleaning techniques are less than their disadvantages. In this study, the uses of laser cleaning method and two modified recipes of wet cleaning methods were evaluated for cleaning of the corroded archaeological Egyptian copper embroidery threads on an archaeological Egyptian textile fabric. Some corroded copper thread samples were cleaned using modified recipes of wet cleaning method; other corroded copper thread samples were cleaned with Q-switched Nd:YAG laser radiation of wavelength 532 nm. All tested metal thread samples before and after cleaning were investigated using a light microscope and a scanning electron microscope with an energy dispersive X-ray analysis unit. Also the laser-induced breakdown spectroscopy (LIBS) technique was used for the elemental analysis of laser-cleaned samples to follow up the laser cleaning procedure. The results show that laser cleaning is the most effective method among all tested methods in the cleaning of corroded copper threads. It can be used safely in removing the corrosion products without any damage to both metal strips and fibrous core. The tested laser cleaning technique has solved the problems caused by other traditional cleaning techniques that are commonly used in the cleaning of metal threads on museum textiles.

  17. Evaluation of adenosine triphosphate test for cleaning assessment of gastroscopes and the effect on workload in a busy endoscopy center.

    PubMed

    Schmitt, Cristiane; Pires Maciel, Amanda Luiz; Boszczowski, Icaro; da Silva, Thaís Pereira; Neves, Eliane Aparecida Job; Rossini, Giulio Fabio; Rizek, Camila; Costa, Silvia Figueiredo; Lourenço, Rogério Ferreira; Alfa, Michelle J

    2018-05-18

    Using adenosine triphosphate (ATP) tests to assess manual cleaning of gastroscopes and to determine the associated workload in a busy endoscopy unit. Patient-used gastroscopes were sampled before and after cleaning to assess ATP levels, bioburden, and protein. Samples were collected by flushing 20 mL of sterile water through the biopsy port to the distal end. Time spent for reprocessing and performing the ATP test was recorded. Twenty-four samples were collected from 10 gastroscopes. After manual cleaning, 14/24 (58.3%) samples had no microbial growth (mean, 21 colony-forming units/cm 2 ), and in 22/24 (91.7%) samples the protein was undetectable (mean, 0.04 µg/cm 2 ). ATP test was above the cutoff (200 relative light units [RLU]) in 17/24 (70.8%) samples (mean, 498 RLU). After the second cleaning, 11/17 (64.7%) gastroscopes still failed the ATP test (mean, 321.2 RLU). The mean time spent to perform manual cleaning and ATP tests was 16 and 8 minutes, respectively. Hence, each test increased the length of time for cleaning plus testing cleanliness by 50%. Further studies regarding the optimal cutoff for ATP tests are needed. ATP tests for cleaning monitoring are easy to perform and provide immediate feedback to the team. However, the increased workload needs to be considered. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Tidd hot gas clean up program. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This Final Report on the Tidd Hot Gas Clean Up Program covers the period from initial Proof-of-Concept testing in August, 1990, through final equipment inspections in May, 1995. The Tidd Hot Gas Clean Up (HGCU) system was installed in the Tidd Pressurized Fluidized Bed Combustion (PFBC) Demonstration Plant, which is the first utility-scale PFBC plant in the United States. Detailed design work on the project began in July, 1990, and site construction began in December, 1991. Initial operation of the system occurred in May, 1992, and the hot gas filter was commissioned in October, 1992. The test program ended inmore » March, 1995, when the Tidd Plant was shut down following its four-year test program. Section 1.0 of this report is an executive summary of the project covering the project background, system description, test results and conclusions. Section 2.0 is an introduction covering the program objectives and schedule. Section 3.0 provides detailed descriptions of the system and its major components. Section 4.0 provides detailed results of all testing including observations and posttest inspection results. Sections 5.0 and 6.0 list the program conclusions and recommendations, respectively. Appendix I is a report prepared by Southern Research Institute on the properties of Tidd PFBC ash sampled during the test program. Appendix II is a report prepared by Westinghouse STC on the performance of candle filter fail-safe regenerator devices.« less

  19. Demonstration of a 1 MWe biomass power plant at USMC Base Camp Lejeune. Report for July 1994-May 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cleland, J.; Purvis, C.R.

    1998-06-01

    The paper discusses a biomass energy conversion project being sponsored by EPA to demonstrate an enviromentally and economically sound electrical power option for government installations, industrial sites, rural cooperatives, small municipalities, and developing countries. Wood gasification combined with internal combustion engines was chosen because of (1) recent improvements in gas cleaning, (2) simple economical operation for units < 10 MW, and (3) the option of a clean cheap fuel for the many existing facilities generating expensive electricity from petroleum fuels with reciprocating engines. The plant incorporates a downdraft, moving-bed gasifier utilizing hogged waste wood from the Marine Corps Base atmore » Camp Lejeune, NC. A moving-bed bulk wood dryer and both spark ignition and diesel engines are included. Unique process design features are described briefly, relative to the gasifier, wood drying, tar separation, and process control. A test plan for process optimization and demonstration of reliability, economics, and environmental impact is outlined.« less

  20. Sealed Silver-oxide Cadmium Batteries for Space Flight, 1960 - 1977

    NASA Technical Reports Server (NTRS)

    Hennigan, Thomas J.

    1978-01-01

    A technical summary of design, development, and test activities with Silver-Oxide Cadmium Batteries at the Goddard Space Flight Center since 1960 is given. The flight experience of over 15 missions has demonstrated the sealed Silver-Oxide Cadmium Battery to be a viable energy storage device for missions requiring ultra-clean magnetic environment.

  1. How Clean Are Hotel Rooms? Part I: Visual Observations vs. Microbiological Contamination.

    PubMed

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Current evidence of hotel room cleanliness is based on observation rather than empirically based microbial assessment. The purpose of the study described here was to determine if observation provides an accurate indicator of cleanliness. Results demonstrated that visual assessment did not accurately predict microbial contamination. Although testing standards have not yet been established for hotel rooms and will be evaluated in Part II of the authors' study, potential microbial hazards included the sponge and mop (housekeeping cart), toilet, bathroom floor, bathroom sink, and light switch. Hotel managers should increase cleaning in key areas to reduce guest exposure to harmful bacteria.

  2. Development of CFC-Free Cleaning Processes at the NASA White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Beeson, Harold; Kirsch, Mike; Hornung, Steven; Biesinger, Paul

    1995-01-01

    The NASA White Sands Test Facility (WSTF) is developing cleaning and verification processes to replace currently used chlorofluorocarbon-113- (CFC-113-) based processes. The processes being evaluated include both aqueous- and solvent-based techniques. The presentation will include the findings of investigations of aqueous cleaning and verification processes that are based on a draft of a proposed NASA Kennedy Space Center (KSC) cleaning procedure. Verification testing with known contaminants, such as hydraulic fluid and commonly used oils, established correlations between nonvolatile residue and CFC-113. Recoveries ranged from 35 to 60 percent of theoretical. WSTF is also investigating enhancements to aqueous sampling for organics and particulates. Although aqueous alternatives have been identified for several processes, a need still exists for nonaqueous solvent cleaning, such as the cleaning and cleanliness verification of gauges used for oxygen service. The cleaning effectiveness of tetrachloroethylene (PCE), trichloroethylene (TCE), ethanol, hydrochlorofluorocarbon-225 (HCFC-225), tert-butylmethylether, and n-Hexane was evaluated using aerospace gauges and precision instruments and then compared to the cleaning effectiveness of CFC-113. Solvents considered for use in oxygen systems were also tested for oxygen compatibility using high-pressure oxygen autoignition and liquid oxygen mechanical impact testing.

  3. Assessment of test methods for evaluating effectiveness of cleaning flexible endoscopes.

    PubMed

    Washburn, Rebecca E; Pietsch, Jennifer J

    2018-06-01

    Strict adherence to each step of reprocessing is imperative to removing potentially infectious agents. Multiple methods for verifying proper reprocessing exist; however, each presents challenges and limitations, and best practice within the industry has not been established. Our goal was to evaluate endoscope cleaning verification tests with particular interest in the evaluation of the manual cleaning step. The results of the cleaning verification tests were compared with microbial culturing to see if a positive cleaning verification test would be predictive of microbial growth. This study was conducted at 2 high-volume endoscopy units within a multisite health care system. Each of the 90 endoscopes were tested for adenosine triphosphate, protein, microbial growth via agar plate, and rapid gram-negative culture via assay. The endoscopes were tested in 3 locations: the instrument channel, control knob, and elevator mechanism. This analysis showed substantial level of agreement between protein detection postmanual cleaning and protein detection post-high-level disinfection at the control head for scopes sampled sequentially. This study suggests that if protein is detected postmanual cleaning, there is a significant likelihood that protein will also be detected post-high-level disinfection. It also infers that a cleaning verification test is not predictive of microbial growth. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Ground test for vibration control demonstrator

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Prodigue, J.; Broux, G.; Cantinaud, O.; Poussot-Vassal, C.

    2016-09-01

    In the objective of maximizing comfort in Falcon jets, Dassault Aviation is developing an innovative vibration control technology. Vibrations of the structure are measured at several locations and sent to a dedicated high performance vibration control computer. Control laws are implemented in this computer to analyse the vibrations in real time, and then elaborate orders sent to the existing control surfaces to counteract vibrations. After detailing the technology principles, this paper focuses on the vibration control ground demonstration that was performed by Dassault Aviation in May 2015 on Falcon 7X business jet. The goal of this test was to attenuate vibrations resulting from fixed forced excitation delivered by shakers. The ground test demonstrated the capability to implement an efficient closed-loop vibration control with a significant vibration level reduction and validated the vibration control law design methodology. This successful ground test was a prerequisite before the flight test demonstration that is now being prepared. This study has been partly supported by the JTI CleanSky SFWA-ITD.

  5. Use of Synthetic Single-Stranded Oligonucleotides as Artificial Test Soiling for Validation of Surgical Instrument Cleaning Processes

    PubMed Central

    Wilhelm, Nadja; Perle, Nadja; Simmoteit, Robert; Schlensak, Christian; Wendel, Hans P.; Avci-Adali, Meltem

    2014-01-01

    Surgical instruments are often strongly contaminated with patients' blood and tissues, possibly containing pathogens. The reuse of contaminated instruments without adequate cleaning and sterilization can cause postoperative inflammation and the transmission of infectious diseases from one patient to another. Thus, based on the stringent sterility requirements, the development of highly efficient, validated cleaning processes is necessary. Here, we use for the first time synthetic single-stranded DNA (ssDNA_ODN), which does not appear in nature, as a test soiling to evaluate the cleaning efficiency of routine washing processes. Stainless steel test objects were coated with a certain amount of ssDNA_ODN. After cleaning, the amount of residual ssDNA_ODN on the test objects was determined using quantitative real-time PCR. The established method is highly specific and sensitive, with a detection limit of 20 fg, and enables the determination of the cleaning efficiency of medical cleaning processes under different conditions to obtain optimal settings for the effective cleaning and sterilization of instruments. The use of this highly sensitive method for the validation of cleaning processes can prevent, to a significant extent, the insufficient cleaning of surgical instruments and thus the transmission of pathogens to patients. PMID:24672793

  6. A study of blood contamination of Siqveland matrix bands.

    PubMed

    Lowe, A H; Bagg, J; Burke, F J T; MacKenzie, D; McHugh, S

    2002-01-12

    AIMS To use a sensitive forensic test to measure blood contamination of used Siqveland matrix bands following routine cleaning and sterilisation procedures in general dental practice. Sixteen general dental practices in the West of Scotland participated. Details of instrument cleaning procedures were recorded for each practice. A total of 133 Siqveland matrix bands were recovered following cleaning and sterilisation and were examined for residual blood contamination by the Kastle-Meyer test, a well-recognised forensic technique. Ultrasonic baths were used for the cleaning of 62 (47%) bands and retainers and the remainder (53%) were hand scrubbed prior to autoclaving. Overall, 21% of the matrix bands and 19% of the retainers gave a positive Kastle-Meyer test, indicative of residual blood contamination, following cleaning and sterilisation. In relation to cleaning method, 34% of hand-scrubbed bands and 32% of hand-scrubbed retainers were positive for residual blood by the Kastle-Meyer test compared with 6% and 3% respectively of ultrasonically cleaned bands and retainers (P < 0.001). If Siqveland matrix bands are re-processed in the assembled state, then adequate pre-sterilisation cleaning cannot be achieved reliably. Ultrasonic baths are significantly more effective than hand cleaning for these items of equipment.

  7. Structural Break, Stock Prices of Clean Energy Firms and Carbon Market

    NASA Astrophysics Data System (ADS)

    Wang, Yubao; Cai, Junyu

    2018-03-01

    This paper uses EU ETS carbon future price and Germany/UK clean energy firms stock indices to study the relationship between carbon market and clean energy market. By structural break test, it is found that the ‘non-stationary’ variables judged by classical unit root test do own unit roots and need taking first difference. After analysis of VAR and Granger causality test, no causal relationships are found between the two markets. However, when Hsiao’s version of causality test is employed, carbon market is found to have power in explaining the movement of stock prices of clean energy firms, and stock prices of clean energy firms also affect the carbon market.

  8. Ultrasonic cleaning of conveyor belt materials using Listeria monocytogenes as a model organism.

    PubMed

    Tolvanén, Riina; Lunden, Janne; Korkeala, Hannu; Wirtanen, Gun

    2007-03-01

    Persistent Listeria monocytogenes contamination of food industry equipment is a difficult problem to solve. Ultrasonic cleaning offers new possibilities for cleaning conveyors and other equipment that are not easy to clean. Ultrasonic cleaning was tested on three conveyor belt materials: polypropylene, acetal, and stainless steel (cold-rolled, AISI 304). Cleaning efficiency was tested at two temperatures (30 and 45 degrees C) and two cleaning times (30 and 60 s) with two cleaning detergents (KOH, and NaOH combined with KOH). Conveyor belt materials were soiled with milk-based soil and L. monocytogenes strains V1, V3, and B9, and then incubated for 72 h to attach bacteria to surfaces. Ultrasonic cleaning treatments reduced L. monocytogenes counts on stainless steel 4.61 to 5.90 log units; on acetal, 3.37 to 5.55 log units; and on polypropylene, 2.31 to 4.40 log units. The logarithmic reduction differences were statistically analyzed by analysis of variance using Statistical Package for the Social Sciences software. The logarithmic reduction was significantly greater in stainless steel than in plastic materials (P < 0.001 for polypropylene, P = 0.023 for acetal). Higher temperatures enhanced the cleaning efficiency in tested materials. No significant difference occurred between cleaning times. The logarithmic reduction was significantly higher (P = 0.013) in cleaning treatments with potassium hydroxide detergent. In this study, ultrasonic cleaning was efficient for cleaning conveyor belt materials.

  9. Cleaner mites: sanitary mutualism in the miniature ecosystem of neotropical bee nests.

    PubMed

    Biani, Natalia B; Mueller, Ulrich G; Wcislo, William T

    2009-06-01

    Cleaning symbioses represent classic models of mutualism, and some bee mites are thought to perform cleaning services for their hosts in exchange for suitable environments for reproduction and dispersal. These mutual benefits, however, have not been rigorously demonstrated. We tested the sanitary role of bee mites by correlating mite loads with fungal contamination in natural nests of Megalopta genalis and Megalopta ecuadoria and by experimentally manipulating mite loads in artificial cells with developing brood. Field observations revealed significant correlations between the presence of mites and the absence of fungi inside the brood cells, as well as between the absence of mites and increased bee mortality. Likewise, experimental brood cells with mites have fewer fungal colonies than do cells without mites. Field observations and experimental manipulations, therefore, provide clear evidence of the sanitary effect of mites in nests of Megalopta bees. This bee-mite association constitutes one of the few examples of terrestrial cleaning mutualisms.

  10. Contamination control and assay results for the Majorana Demonstrator ultra clean components

    NASA Astrophysics Data System (ADS)

    Christofferson, C. D.; Abgrall, N.; Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Bode, T.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Gilliss, T.; Giovanetti, G. K.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; O'Shaughnessy, C.; Othman, G.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Robertson, R. G. H.; Rouf, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.; Zhu, B. X.

    2018-01-01

    The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. This article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

  11. CleanFleet final report : executive summary

    DOT National Transportation Integrated Search

    1995-12-01

    CleanFleet, formally known as the South Coast Alternative Fuels Demonstration, : was a comprehensive demonstration of alternative fuel vehicles (AFVs) in daily : commercial service. Between April 1992 and September 1994, five alternative fuels were t...

  12. California Clean Tech

    EPA Pesticide Factsheets

    The California Clean Air Technology Initiative is a partnership to develop clean air technologies for the San Joaquin Valley and South Coast Air Basins through collaborative projects in technology research, development, demonstration, and deployment.

  13. 16 CFR 1610.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... mechanism of the test apparatus. (c) Dry cleaning means the cleaning of samples in a commercial dry cleaning... 1 second during which the ignition flame is applied to the test specimen. (g) Ignition means that there is a self-sustaining flame on the specimen after the test flame is removed. (h) Interlining means...

  14. 16 CFR 1610.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... mechanism of the test apparatus. (c) Dry cleaning means the cleaning of samples in a commercial dry cleaning... 1 second during which the ignition flame is applied to the test specimen. (g) Ignition means that there is a self-sustaining flame on the specimen after the test flame is removed. (h) Interlining means...

  15. 16 CFR § 1610.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... mechanism of the test apparatus. (c) Dry cleaning means the cleaning of samples in a commercial dry cleaning... 1 second during which the ignition flame is applied to the test specimen. (g) Ignition means that there is a self-sustaining flame on the specimen after the test flame is removed. (h) Interlining means...

  16. 16 CFR 1610.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... mechanism of the test apparatus. (c) Dry cleaning means the cleaning of samples in a commercial dry cleaning... 1 second during which the ignition flame is applied to the test specimen. (g) Ignition means that there is a self-sustaining flame on the specimen after the test flame is removed. (h) Interlining means...

  17. Supercritical CO2 Cleaning for Planetary Protection and Contamination Control

    NASA Technical Reports Server (NTRS)

    Lin, Ying; Zhong, Fang; Aveline, David; Anderson, Mark; Chung, Shirley; Mennella, Jerami; Schubert, Wayne

    2010-01-01

    We have designed and built a prototype Supercritical CO? Cleaning (SCC) system at JPL. The key features of the system are: 1) the parts inside a high-pressure vessel can be rotated at high speeds; 2) the same thermodynamic condition is maintained during First-In First-Out flushing to keep solvent power constant; and 3) the boil-off during decompression is induced in a separate vessel downstream. Our goal is to demonstrate SCC's ability to remove trace amounts of microbial and organic contaminants down to parts per billion levels from spacecraft material surfaces for future astrobiology missions. The initial cleaning test results showed that SCC can achieve cleanliness levels of 0.01 microgram/cm(sup 2) or less for hydrophobic contaminants such as dioctyl phthalate and silicone and it is less effective in the removal and inactivation of the hydrophilic bacterial spores as expected. However, with the use of a polar co-solvent, the efficacy may improve dramatically. The same results were obtained using liquid CO?. This opens up the possibility of using subcritical cleaning conditions, which may prove to be more compatible with certain spacecraft hardware.

  18. Comparison of Clean-Up Methods for Ochratoxin A on Wine, Beer, Roasted Coffee and Chili Commercialized in Italy

    PubMed Central

    Prelle, Ambra; Spadaro, Davide; Denca, Aleksandra; Garibaldi, Angelo; Gullino, Maria Lodovica

    2013-01-01

    The most common technique used to detect ochratoxin A (OTA) in food matrices is based on extraction, clean-up, and chromatography detection. Different clean-up cartridges, such as immunoaffinity columns (IAC), molecular imprinting polymers (MIP), Mycosep™ 229, Mycospin™, and Oasis® HLB (Hydrophilic Lipophilic balance) as solid phase extraction were tested to optimize the purification for red wine, beer, roasted coffee and chili. Recovery, reproducibility, reproducibility, limit of detection (LOD) and limit of quantification (LOQ) were calculated for each clean-up method. IAC demonstrated to be suitable for OTA analysis in wine and beer with recovery rate >90%, as well as Mycosep™ for wine and chili. On the contrary, MIP columns were the most appropriate to clean up coffee. A total of 120 samples (30 wines, 30 beers, 30 roasted coffee, 30 chili) marketed in Italy were analyzed, by applying the developed clean-up methods. Twenty-seven out of 120 samples analyzed (22.7%: two wines, five beers, eight coffees, and 12 chili) resulted positive to OTA. A higher incidence of OTA was found in chili (40.0%) more than wine (6.6%), beers (16.6%) and coffee (26.6%). Moreover, OTA concentration in chili was the highest detected, reaching 47.8 µg/kg. Furthermore, three samples (2.5%), two wines and one chili, exceeded the European threshold. PMID:24152987

  19. Clean Coal Technology Demonstration Program: Program Update 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Assistant Secretary for Fossil Energy

    1999-03-01

    Annual report on the Clean Coal Technology Demonstration Program (CCT Program). The report address the role of the CCT Program, implementation, funding and costs, accomplishments, project descriptions, legislative history, program history, environmental aspects, and project contacts. The project descriptions describe the technology and provides a brief summary of the demonstration results.

  20. Independent Verification Survey of the Clean Coral Storage Pile at the Johnston Atoll Plutonium-Contaminated Soil Remediation Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson-Nichols, M.J.

    2000-12-07

    The Oak Ridge National Laboratory (ORNL) Environmental Technology Section conducted an independent verification (IV) survey of the clean storage pile at the Johnston Atoll Plutonium Contaminated Soil Remediation Project (JAPCSRP) from January 18-25, 1999. The goal of the JAPCSRP is to restore a 24-acre area that was contaminated with plutonium oxide particles during nuclear testing in the 1960s. The selected remedy was a soil sorting operation that combined radiological measurements and mining processes to identify and sequester plutonium-contaminated soil. The soil sorter operated from about 1990 to 1998. The remaining clean soil is stored on-site for planned beneficial use onmore » Johnston Island. The clean storage pile currently consists of approximately 120,000 m{sup 3} of coral. ORNL conducted the survey according to a Sampling and Analysis Plan, which proposed to provide an IV of the clean pile by collecting a minimum number (99) of samples. The goal was to ascertain with 95% confidence whether 97% of the processed soil is less than or equal to the accepted guideline (500-Bq/kg or 13.5-pCi/g) total transuranic (TRU) activity. In previous IV tasks, ORNL has (1) evaluated and tested the soil sorter system software and hardware and (2) evaluated the quality control (QC) program used at the soil sorter plant. The IV has found that the soil sorter decontamination was effective and significantly reduced plutonium contamination in the soil processed at the JA site. The Field Command Defense Threat Reduction Agency currently plans to re-use soil from the clean pile as a cover to remaining contamination in portions of the radiological control area. Therefore, ORNL was requested to provide an IV. The survey team collected samples from 103 random locations within the top 4 ft of the clean storage pile. The samples were analyzed in the on-site radioanalytical counting laboratory with an American Nuclear Systems (ANS) field instrument used for the detection of low-energy radiation. Nine results exceeded the JA soil screening guideline for distributed contamination of 13.5 pCi/g for total TRUs, ranging from 13.7 to 125.9 pCi/g. Because of these results, the goal of showing with 95% confidence that 97% of the processed soil is less than or equal to 13.5 pCi/g-TRU activity cannot be met. The value of 13.5 pCi/g represents the 88th percentile rather than the 95th percentile in a nonparametric one-sided upper 90% confidence limit. Therefore, at the 95% confidence level, 88% of the clean pile is projected to be below the 13.5-pCi/g goal. The Multi-Agency Radiation Survey and Site Investigation Manual recommends use of a nonparametric statistical ''Sign Test'' to demonstrate compliance with release criteria for TRU. Although this survey was not designed to use the sign test, the data herein would demonstrate that the median (50%) of the clean storage pile is below the l3.5-pCi/g derived concentration guideline level. In other words, with the caveat that additional investigation of elevated concentrations was not performed, the data pass the sign test at the 13.5-pCi/g level. Additionally, the lateral extent of the pile was gridded, and 10% of the grid blocks was scanned with field instruments for the detection of low-energy radiation coupled to ratemeter/scalers to screen for the presence of hot particles. No hot particles were detected in the top 1 cm of the grid blocks surveyed.« less

  1. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

    PubMed

    Kampf, Günter; Fliss, Patricia M; Martiny, Heike

    2014-09-16

    The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes.

  2. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

    PubMed Central

    Kampf, Günter; Fliss, Patricia M; Martiny, Heike

    2014-01-01

    The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes. PMID:25228941

  3. Oil Spill Cleanup

    ERIC Educational Resources Information Center

    Kauble, Christena Ann

    2011-01-01

    Several classroom activities using a model of a seashore and an oil spill demonstrate the basic properties of oil spills in oceans. Students brainstorm about how to best clean up the mess. They work in teams, and after agreeing on how they will proceed, their method is tested by measuring the amount of oil removed and by rating the cleanliness of…

  4. Stability of reference masses: VII. Cleaning methods in air and vacuum applied to a platinum mass standard similar to the international and national kilogram prototypes

    NASA Astrophysics Data System (ADS)

    Cumpson, Peter J.; Sano, Naoko; Barlow, Anders J.; Portoles, Jose F.

    2013-10-01

    Mercury contamination and the build-up of carbonaceous contamination are two contributing factors to the instability observed in kilogram prototype masses. The kilogram prototypes that lie at the core of the dissemination of the SI base unit were manufactured in the late 19th century, and have polished surfaces. In papers IV and V of this series we developed a method for cleaning noble metal mass standards in air to remove carbonaceous contamination. At the core of this ‘UVOPS’ protocol is the application of UV light and ozone gas generated in situ in air. The precise nature of the carbonaceous contamination that builds up on such surfaces is difficult to mimic demonstrably or quickly on new test surfaces, yet data from such tests are needed to provide the final confidence to allow UVOPS to be applied to a real 19th century kilogram prototype. Therefore, in the present work we have applied the UVOPS method to clean a platinum avoirdupois pound mass standard, ‘RS2’, manufactured in the mid-19th century. This is thought to have been polished in a similar manner to the kilogram prototypes. To our knowledge this platinum surface has not previously been cleaned by any method. We used x-ray photoelectron spectroscopy to identify organic contamination, and weighing to quantify the mass lost at each application of the UVOPS procedure. The UVOPS procedure is shown to be very effective. It is likely that the redefinition of the kilogram will require mass comparisons in vacuum in the years to come. Therefore, in addition to UVOPS a cleaning method for use in vacuum will also be needed. We introduce and evaluate gas cluster ion-beam (GCIB) treatment as a potential method for cleaning reference masses in vacuum. Again, application of this GCIB cleaning to a real artefact, RS2, allows us to make a realistic evaluation of its performance. While it has some attractive features, we cannot recommend it for cleaning mass standards in its present form.

  5. Data cleaning in the energy domain

    NASA Astrophysics Data System (ADS)

    Akouemo Kengmo Kenfack, Hermine N.

    This dissertation addresses the problem of data cleaning in the energy domain, especially for natural gas and electric time series. The detection and imputation of anomalies improves the performance of forecasting models necessary to lower purchasing and storage costs for utilities and plan for peak energy loads or distribution shortages. There are various types of anomalies, each induced by diverse causes and sources depending on the field of study. The definition of false positives also depends on the context. The analysis is focused on energy data because of the availability of data and information to make a theoretical and practical contribution to the field. A probabilistic approach based on hypothesis testing is developed to decide if a data point is anomalous based on the level of significance. Furthermore, the probabilistic approach is combined with statistical regression models to handle time series data. Domain knowledge of energy data and the survey of causes and sources of anomalies in energy are incorporated into the data cleaning algorithm to improve the accuracy of the results. The data cleaning method is evaluated on simulated data sets in which anomalies were artificially inserted and on natural gas and electric data sets. In the simulation study, the performance of the method is evaluated for both detection and imputation on all identified causes of anomalies in energy data. The testing on utilities' data evaluates the percentage of improvement brought to forecasting accuracy by data cleaning. A cross-validation study of the results is also performed to demonstrate the performance of the data cleaning algorithm on smaller data sets and to calculate an interval of confidence for the results. The data cleaning algorithm is able to successfully identify energy time series anomalies. The replacement of those anomalies provides improvement to forecasting models accuracy. The process is automatic, which is important because many data cleaning processes require human input and become impractical for very large data sets. The techniques are also applicable to other fields such as econometrics and finance, but the exogenous factors of the time series data need to be well defined.

  6. CleanFleet final report. Volume 1, summary

    DOT National Transportation Integrated Search

    1995-12-01

    The South Coast Alternative Fuels Demonstration, called CleanFleet, was conducted in the Los Angeles area from April 1992 through September 1994. The demonstration consisted of 111 package delivery vans operating on five alternative fuels and the con...

  7. CleanFleet final report. Volume 4, fuel economy

    DOT National Transportation Integrated Search

    1995-12-01

    The South Coast Alternative Fuels Demonstration, called CleanFleet, was conducted in the Los Angeles area from April 1992 through September 1994. The demonstration consisted of 111 package delivery vans operating on five alternative fuels and the con...

  8. CleanFleet final report. Volume 6, occupational hygiene

    DOT National Transportation Integrated Search

    1995-12-01

    The South Coast Alternative Fuels Demonstration, called CleanFleet, was conducted in the Los Angeles area from April 1992 through September 1994. The demonstration consisted of 111 package delivery vans operating on five alternative fuels and the con...

  9. CleanFleet final report. Volume 5, employee attitude assessment

    DOT National Transportation Integrated Search

    1995-12-01

    The South Coast Alternative Fuels Demonstration, called CleanFleet, was conducted in the Los Angeles area from April 1992 through September 1994. The demonstration consisted of 111 package delivery vans operating on five alternative fuels and the con...

  10. The use of immunoaffinity columns connected in tandem for selective and cost-effective mycotoxin clean-up prior to multi-mycotoxin liquid chromatographic-tandem mass spectrometric analysis in food matrices.

    PubMed

    Wilcox, Joyce; Donnelly, Carol; Leeman, David; Marley, Elaine

    2015-06-26

    This paper describes the use of two immunoaffinity columns (IACs) coupled in tandem, providing selective clean-up, based on targeted mycotoxins known to co-occur in specific matrices. An IAC for aflatoxins+ochratoxin A+fumonisins (AOF) was combined with an IAC for deoxynivalenol+zearalenone+T-2/HT-2 toxins (DZT); an IAC for ochratoxin A (O) was combined with a DZT column; and an aflatoxin+ochratoxin (AO) column was combined with a DZT column. By combining pairs of columns it was demonstrated that specific clean-up can be achieved as required for different matrices. Samples of rye flour, maize, breakfast cereal and wholemeal bread were analysed for mycotoxins regulated in the EU, by spiking at levels close to EU limits for adult and infant foods. After IAC clean-up extracts were analysed by LC-MS/MS with quantification using multiple reaction monitoring. Recoveries were found to be in range from 60 to 108%, RSDs below 10% depending on the matrix and mycotoxin combination and LOQs ranged from 0.1n g/g for aflatoxin B1 to 13.0 ng/g for deoxynivalenol. Surplus cereal proficiency test materials (FAPAS(®)) were also analysed with found levels of mycotoxins falling within the satisfactory range of concentrations (Z score ≤ ± 2), demonstrating the accuracy of the proposed multi-mycotoxin IAC methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Alternative Chemical Cleaning Methods for High Level Waste Tanks: Simulant Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudisill, T.; King, W.; Hay, M.

    Solubility testing with simulated High Level Waste tank heel solids has been conducted in order to evaluate two alternative chemical cleaning technologies for the dissolution of sludge residuals remaining in the tanks after the exhaustion of mechanical cleaning and sludge washing efforts. Tests were conducted with non-radioactive pure phase metal reagents, binary mixtures of reagents, and a Savannah River Site PUREX heel simulant to determine the effectiveness of an optimized, dilute oxalic/nitric acid cleaning reagent and pure, dilute nitric acid toward dissolving the bulk non-radioactive waste components. A focus of this testing was on minimization of oxalic acid additions duringmore » tank cleaning. For comparison purposes, separate samples were also contacted with pure, concentrated oxalic acid which is the current baseline chemical cleaning reagent. In a separate study, solubility tests were conducted with radioactive tank heel simulants using acidic and caustic permanganate-based methods focused on the “targeted” dissolution of actinide species known to be drivers for Savannah River Site tank closure Performance Assessments. Permanganate-based cleaning methods were evaluated prior to and after oxalic acid contact.« less

  12. Benzotriazole removal on post-Cu CMP cleaning

    NASA Astrophysics Data System (ADS)

    Jiying, Tang; Yuling, Liu; Ming, Sun; Shiyan, Fan; Yan, Li

    2015-06-01

    This work investigates systematically the effect of FA/O II chelating agent and FA/O I surfactant in alkaline cleaning solutions on benzotriazole (BTA) removal during post-Cu CMP cleaning in GLSI under the condition of static etching. The best detergent formulation for BTA removal can be determined by optimization of the experiments of single factor and compound cleaning solution, which has been further confirmed experimentally by contact angle (CA) measurements. The resulting solution with the best formulation has been measured for the actual production line, and the results demonstrate that the obtained cleaning solution can effectively and efficiently remove BTA, CuO and abrasive SiO2 without basically causing interfacial corrosion. This work demonstrates the possibility of developing a simple, low-cost and environmentally-friendly cleaning solution to effectively solve the issues of BTA removal on post-Cu CMP cleaning in a multi-layered copper wafer. Project supported by the Major National Science and Technology Special Projects (No. 2009ZX02308).

  13. Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels.

    PubMed

    Alfa, Michelle J; Fatima, Iram; Olson, Nancy

    2013-03-01

    Compliance with cleaning of flexible endoscope channels cannot be verified using visual inspection. Adenosine triphosphate (ATP) has been suggested as a possible rapid cleaning monitor for flexible endoscope channels. There have not been published validation studies to specify the level of ATP that indicates inadequate cleaning has been achieved. The objective of this study was to validate the Clean-Trace (3M Inc, St. Paul, MN) ATP water test method for monitoring manual cleaning of flexible endoscopes. This was a simulated use study using a duodenoscope as the test device. Artificial test soil containing 10(6) colony-forming units of Pseudomonas aeruginosa and Enterococcus faecalis was used to perfuse all channels. The flush sample method for the suction-biopsy (L1) or air-water channel (L2) using 40 and 20 mLs sterile reverse osmosis water, respectively, was validated. Residuals of ATP, protein, hemoglobin, and bioburden were quantitated from channel samples taken from uncleaned, partially cleaned, and fully cleaned duodenoscopes. The benchmarks for clean were as follows: <6.4 μg/cm(2) protein, <2.2 μg/cm(2) hemoglobin, and <4-log10 colony-forming units/cm(2) bioburden. The average ATP in clean channel samples was 27.7 RLUs and 154 RLUs for L1 and L2, respectively (<200 RLUs for all channels). The average protein, hemoglobin, and bioburden benchmarks were achieved if <200 RLUs were detected. If the channel sample was >200 RLUs, the residual organic and bioburden levels would exceed the acceptable benchmarks. Our data validated that flexible endoscopes that have complete manual cleaning will have <200 RLUs by the Clean-Trace ATP test. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  14. Comparison of Decontamination Efficacy of Cleaning Solutions on a Biological Safety Cabinet Workbench Contaminated by Cyclophosphamide

    PubMed Central

    Adé, Apolline; Chauchat, Laure; Frève, Johann-François Ouellette; Gagné, Sébastien; Caron, Nicolas; Bussières, Jean-François

    2017-01-01

    Background Several studies have compared cleaning procedures for decontaminating surfaces exposed to antineoplastic drugs. All of the cleaning products tested were successful in reducing most of the antineoplastic drug quantities spilled on surfaces, but none of them completely removed residual traces. Objective To assess the efficacy of various cleaning solutions for decontaminating a biological safety cabinet workbench exposed to a defined amount of cyclophosphamide. Methods In this pilot study, specific areas of 2 biological safety cabinets (class II, type B2) were deliberately contaminated with a defined quantity of cyclophosphamide (10 μg or 107 pg). Three cleaning solutions were tested: quaternary ammonium, sodium hypochlorite 0.02%, and sodium hypochlorite 2%. After cleaning, the cyclophosphamide remaining on the areas was quantified by wipe sampling. Each cleaning solution was tested 3 times, with cleaning and wipe sampling being performed 5 times for each test. Results A total of 57 wipe samples were collected and analyzed. The average recovery efficiency was 121.690% (standard deviation 5.058%). The decontamination efficacy increased with the number of successive cleaning sessions: from 98.710% after session 1 to 99.997% after session 5 for quaternary ammonium; from 97.027% to 99.997% for sodium hypochlorite 0.02%; and from 98.008% to 100% for sodium hypochlorite 2%. Five additional cleaning sessions performed after the main study (with detergent and sodium hypochlorite 2%) were effective to complete the decontamination, leaving no detectable traces of the drug. Conclusions All of the cleaning solutions reduced contamination of biological safety cabinet workbenches exposed to a defined amount of cyclophosphamide. Quaternary ammonium and sodium hypochlorite (0.02% and 2%) had mean efficacy greater than 97% for removal of the initial quantity of the drug (107 pg) after the first cleaning session. When sodium hypochlorite 2% was used, fewer cleaning sessions were required to complete decontamination. Further studies should be conducted to identify optimal cleaning strategies to fully eliminate traces of hazardous drugs. PMID:29298999

  15. CleanFleet final report. Volume 3, vehicle maintenance and durability

    DOT National Transportation Integrated Search

    1995-12-01

    The South Coast Alternative Fuels Demonstration, called CleanFleet, was conducted in the Los Angeles area from April 1992 through September 1994. The demonstration consisted of 111 package delivery vans operating on five alternative fuels and the con...

  16. Low speed and angle of attack effects on sonic and near-sonic inlets

    NASA Technical Reports Server (NTRS)

    Hickcox, T. E.; Lawrence, R. L.; Syberg, J.; Wiley, D. R.

    1975-01-01

    Tests of the Quiet, Clean Short-Haul Experimental Engine (QCSEE) were conducted to determine the effects of forward velocity and angle of attack on sonic and near-sonic inlet aerodynamic performance penalties and acoustic suppression characteristics. The tests demonstrate that translating centerbody and radial vane sonic inlets, and QCSEE high throat Mach number inlets, can be designed to operate effectively at forward speed and moderate angle of attack with good performance and noise suppression capability. The test equipment and procedures used in conducting the evaluation are described. Results of the tests are presented in tabular form.

  17. Pilot-scale continuous ultrasonic cleaning equipment reduces Listeria monocytogenes levels on conveyor belts.

    PubMed

    Tolvanen, Riina; Lundén, Janne; Hörman, Ari; Korkeala, Hannu

    2009-02-01

    Ultrasonic cleaning of a conveyor belt was studied by building a pilot-scale conveyor with an ultrasonic cleaning bath. A piece of the stainless steel conveyor belt was contaminated with meat-based soil and Listeria monocytogenes strains (V1, V3, and B9) and incubated for 72 h to allow bacteria to attach to the conveyor belt surfaces. The effect of ultrasound with a potassium hydroxide-based cleaning detergent was determined by using the cleaning bath at 45 and 50 degrees C for 30 s with and without ultrasound. The detachment of L. monocytogenes from the conveyor belt caused by the ultrasonic treatment was significantly greater at 45 degrees C (independent samples t test, P < 0.001) and at 50 degrees C (independent samples t test, P = 0.04) than without ultrasound. Ultrasonic cleaning efficiency was tested with different cleaning durations (10, 15, 20, and 30 s) and temperatures (30, 45, and 50 degrees C). The differences in the log reduction between cleaning treatments were analyzed by analysis of variance with Tamhane's T2 posthoc test using SPSS (Chicago, IL). The lengthening of the treatment time from 10 to 30 s did not significantly increase the detachment of L. monocytogenes (ANOVA 0.633). At 30 degrees C and at the longest time tested (30 s), the treatment reduced L. monocytogenes counts by only 2.68 log units. However, an increase in temperature from 30 to 50 degrees C improved the effect of the ultrasonic treatment significantly (P < 0.01). Ultrasonic cleaning for 10 s at 50 degrees C reduced L. monocytogenes counts by more than 5 log units. These results indicate that ultrasonic cleaning of a conveyor belt is effective even with short treatment times.

  18. Use of adenosine triphosphate to audit reprocessing of flexible endoscopes with an elevator mechanism.

    PubMed

    Quan, Erik; Mahmood, Rizwan; Naik, Amar; Sargon, Peter; Shastri, Nikhil; Venu, Mukund; Parada, Jorge P; Gupta, Neil

    2018-05-21

    There have been reported outbreaks of carbapenem-resistant Enterobacteriaceae infections linked to endoscopes with elevator mechanisms. Adenosine triphosphate (ATP) testing has been used as a marker for bioburden and monitoring manual cleaning for flexible endoscopes with and without an elevator mechanism. The objective of this study was to determine whether routine ATP testing could identify areas of improvement in cleaning of endoscopes with an elevator mechanism. ATP testing after manual cleaning of TJF-Q180V duodenoscopes and GF-UCT180 linear echoendoscopes (Olympus America Inc, Center Valley, PA) was implemented. Samples were tested from the distal end, the elevator mechanism, and water flushed through the lumen of the biopsy channel. Data were recorded and compared by time point, test point, and reprocessing technician. Overall failure rate was 6.99% (295 out of 4,219). The highest percentage of failed ATP tests (17.05%) was reported in the first quarter of routine testing, with an overall decrease in rates over time. The elevator mechanism and working channel lumen had higher failure rates than the distal end. Quality of manual cleaning between reprocessing technicians showed variation. ATP testing is effective in identifying residual organic material and improving quality of manual cleaning of endoscopes with an elevator mechanism. Cleaning efficacy is influenced by reprocessing technicians and location tested on the endoscope. Close attention to the working channel and elevator mechanism during manual cleaning is warranted. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Self-Scrubbing Coal -- an integrated approach to clean air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrison, K.E.

    1997-12-31

    Carefree Coal is coal cleaned in a proprietary dense-media cyclone circuit, using ultrafine magnetite slurries, to remove noncombustible material, including up to 90% of the pyritic sulfur. Deep cleaning alone, however, cannot produce a compliance fuel from coals with high organic sulfur contents. In these cases, Self-Scrubbing Coal will be produced. Self-Scrubbing Coal is produced in the same manner as Carefree Coal except that the finest fraction of product from the cleaning circuit is mixed with limestone-based additives and briquetted. The reduced ash content of the deeply-cleaned coal will permit the addition of relatively large amounts of sorbent without exceedingmore » boiler ash specifications or overloading electrostatic precipitators. This additive reacts with sulfur dioxide (SO{sub 2}) during combustion of the coal to remove most of the remaining sulfur. Overall, sulfur reductions in the range of 80--90% are achieved. After nearly 5 years of research and development of a proprietary coal cleaning technology coupled with pilot-scale validation studies of this technology and pilot-scale combustion testing of Self-Scrubbing Coal, Custom Coals Corporation organized a team of experts to prepare a proposal in response to DOE`s Round IV Program Opportunity Notice for its Clean Coal Technology Program under Public Law 101-121 and Public Law 101-512. The main objective of the demonstration project is the production of a coal fuel that will result in up to 90% reduction in sulfur emissions from coal-fired boilers at a cost competitive advantage over other technologies designed to accomplish the same sulfur emissions and over naturally occurring low sulfur coals.« less

  20. Development of a laboratory demonstration model active cleaning device

    NASA Technical Reports Server (NTRS)

    Shannon, R. L.; Gillette, R. B.

    1975-01-01

    A laboratory demonstration model of a device for removing contaminant films from optical surfaces in space was developed. The development of a plasma tube, which would produce the desired cleaning effects under high vacuum conditions, represented the major problem in the program. This plasma tube development is discussed, and the resulting laboratory demonstration-model device is described.

  1. Verifying Dissolution Of Wax From Hardware Surfaces

    NASA Technical Reports Server (NTRS)

    Montoya, Benjamina G.

    1995-01-01

    Wax removed by cleaning solvent revealed by cooling solution with liquid nitrogen. Such improved procedure and test needed in case of hardware that must be protected by wax during machining or plating but required to be free of wax during subsequent use. Improved cleaning procedure and test take less than 5 minutes. Does not require special skill or equipment and performs at cleaning site. In addition, enables recovery of all cleaning solvent.

  2. Quiet Clean Short-haul Experimental Engine (QCSEE) Over The Wing (OTW) design report

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The design, fabrication, and testing of two experimental high bypass geared turbofan engines and propulsion systems for short haul passenger aircraft are described. The propulsion technology required for future externally blown flap aircraft with engines located both under the wing and over the wing is demonstrated. Composite structures and digital engine controls are among the topics included.

  3. Active cleaning technique device

    NASA Technical Reports Server (NTRS)

    Shannon, R. L.; Gillette, R. B.

    1973-01-01

    The objective of this program was to develop a laboratory demonstration model of an active cleaning technique (ACT) device. The principle of this device is based primarily on the technique for removing contaminants from optical surfaces. This active cleaning technique involves exposing contaminated surfaces to a plasma containing atomic oxygen or combinations of other reactive gases. The ACT device laboratory demonstration model incorporates, in addition to plasma cleaning, the means to operate the device as an ion source for sputtering experiments. The overall ACT device includes a plasma generation tube, an ion accelerator, a gas supply system, a RF power supply and a high voltage dc power supply.

  4. Fine urban and precursor emissions control for diesel urban transit buses.

    PubMed

    Lanni, Thomas

    2003-01-01

    Particulate emission from diesel engines is one of the most important pollutants in urban areas. As a result, particulate emission control from urban bus diesel engines using particle filter technology is being evaluated at several locations in the US. A project entitled "Clean Diesel Air Quality Demonstration Program" has been initiated by the New York City Metropolitan Transit Authority (MTA) under the supervision of New York State Department of Environmental Conservation and with active participation from Johnson Matthey, Corning, Equilon, Environment Canada and RAD Energy. Under this program, several MTA transit buses with DDC Series 50 engines were equipped with Continuously Regenerating Technology (CRTTM) particulate filter systems and have been operated with ultra low sulfur diesel (<30 ppm S) in transit service in Manhattan since February 2000. These buses were evaluated over a 9-month period for durability and maintainability of the particulate filter. In addition, an extensive emissions testing program was carried out using transient cycles on a chassis dynamometer to evaluate the emissions reductions obtained with the particle filter. In this paper, the emissions testing data from the Clean Diesel Air Quality Demonstration Program are discussed in detail.

  5. Effect of steam sterilization inside the turbine chambers of dental turbines.

    PubMed

    Andersen, H K; Fiehn, N E; Larsen, T

    1999-02-01

    It has been demonstrated that contamination of the insides of high-speed dental turbines occurs and that bacteria as well as viruses may remain infectious when expelled from such turbines during subsequent use. Consequently, it has been widely recommended that a high-speed turbine be sterilized after each patient. The purpose of this study was to evaluate the effect of steam autoclaving on a high-speed dental turbine with a contaminated turbine chamber. Streptococcus salivarius and endospores of Bacillus stearothermophilus were used as test organisms to determine the effectiveness of 4 different small non-vacuum autoclaves and one vacuum autoclave. The study demonstrated different efficiencies among the small non-vacuum autoclaves, the best showing close to a 6 log reduction of the test organisms inside the turbine chamber. When cleaning and lubrication of the high-speed dental turbine was carried out before autoclaving, this level of reduction was observed for all the examined non-vacuum autoclaves. It is concluded that cleaning before sterilization is essential for safe use of high-speed dental turbines and that small non-vacuum autoclaves should be carefully evaluated before being used for the reprocessing of hollow instruments such as high-speed turbines.

  6. Replacement of Hydrochlorofluorocarbon (HCFC) -225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems

    NASA Technical Reports Server (NTRS)

    Burns, H. D.; Mitchell, M. A.; McMillian, J. H.; Farner, B. R.; Harper, S. A.; Peralta, S. F.; Lowrey, N. M.; Ross, H. R.; Juarez, A.

    2015-01-01

    Since the 1990's, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have used hydrochlorofluorocarbon-225 (HCFC-225), a Class II ozone-depleting substance, to safety clean and verify the cleanliness of large scale propulsion oxygen systems and associated test facilities. In 2012 through 2014, test laboratories at MSFC, SSC, and Johnson Space Center-White Sands Test Facility collaborated to seek out, test, and qualify an environmentally preferred replacement for HCFC-225. Candidate solvents were selected, a test plan was developed, and the products were tested for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Honewell Soltice (TradeMark) Performance Fluid (trans-1-chloro-3,3, 3-trifluoropropene) was selected to replace HCFC-225 at NASA's MSFC and SSC rocket propulsion test facilities.

  7. Ultrasonic frequency selection for aqueous fine cleaning

    NASA Technical Reports Server (NTRS)

    Becker, Joann F.

    1995-01-01

    A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Division of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation, frequency vs. cleaning effectiveness, the two types of transducers, and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.

  8. Ultrasonic frequency selection for aqueous fine cleaning

    NASA Technical Reports Server (NTRS)

    Becker, Joann F.

    1994-01-01

    A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Div. of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation; frequency vs. cleaning effectiveness; the two types of transducers; and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.

  9. Rudimentary Cleaning Compared to Level 300A

    NASA Technical Reports Server (NTRS)

    Arpin, Christina Y. Pina; Stoltzfus, Joel

    2012-01-01

    A study was done to characterize the cleanliness level achievable when using a rudimentary cleaning process, and results were compared to JPR 5322.1G Level 300A. While it is not ideal to clean in a shop environment, some situations (e.g., field combat operations) require oxygen system hardware to be maintained and cleaned to prevent a fire hazard, even though it cannot be sent back to a precision cleaning facility. This study measured the effectiveness of basic shop cleaning. Initially, three items representing parts of an oxygen system were contaminated: a metal plate, valve body, and metal oxygen bottle. The contaminants chosen were those most likely to be introduced to the system during normal use: oil, lubricant, metal shavings/powder, sand, fingerprints, tape, lip balm, and hand lotion. The cleaning process used hot water, soap, various brushes, gaseous nitrogen, water nozzle, plastic trays, scouring pads, and a controlled shop environment. Test subjects were classified into three groups: technical professionals having an appreciation for oxygen hazards; professional precision cleaners; and a group with no previous professional knowledge of oxygen or precision cleaning. Three test subjects were in each group, and each was provided with standard cleaning equipment, a cleaning procedure, and one of each of the three test items to clean. The results indicated that the achievable cleanliness level was independent of the technical knowledge or proficiency of the personnel cleaning the items. Results also showed that achieving a Level 300 particle count was more difficult than achieving a Level A nonvolatile residue amount.

  10. Technology summary of the in situ bioremediation demonstration (methane biostimulation) via horizontal wells at the Savannah River Site Integrated Demonstration Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hazen, T.C.; Looney, B.B.; Fliermans, C.B.

    1994-06-01

    The US Department of Energy, Office of Technology Development, has been sponsoring full-scale environmental restoration technology demonstrations for the past 4 years. The Savannah River Site Integrated Demonstration focuses on ``Clean-up of Soils ad Groundwater Contaminated with Chlorinated VOCs.`` Several laboratories including our own had demonstrated the ability of methanotrophic bacteria to completely degrade or mineralize chlorinated solvents, and these bacteria were naturally found in soil and aquifer material. Thus the test consisted of injection of methane mixed with air into the contaminated aquifer via a horizontal well and extraction from the vadose zone via a parallel horizontal well.

  11. NREL Topic 1 Final Report: Cohesive Application of Standards-Based Connected Devices to Enable Clean Energy Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hudgins, Andrew P.; Sparn, Bethany F.; Jin, Xin

    This document is the final report of a two-year development, test, and demonstration project entitled 'Cohesive Application of Standards-Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL) Integrated Network Test-bed for Energy Grid Research and Technology (INTEGRATE) initiative. The Electric Power Research Institute (EPRI) and a team of partners were selected by NREL to carry out a project to develop and test how smart, connected consumer devices can act to enable the use of more clean energy technologies on the electric power grid. The project team includes a set ofmore » leading companies that produce key products in relation to achieving this vision: thermostats, water heaters, pool pumps, solar inverters, electric vehicle supply equipment, and battery storage systems. A key requirement of the project was open access at the device level - a feature seen as foundational to achieving a future of widespread distributed generation and storage. The internal intelligence, standard functionality and communication interfaces utilized in this project result in the ability to integrate devices at any level, to work collectively at the level of the home/business, microgrid, community, distribution circuit or other. Collectively, the set of products serve as a platform on which a wide range of control strategies may be developed and deployed.« less

  12. Alternate retrieval technology demonstrations program - test report (ARD Environmental, Inc.)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berglin, E.J.

    A prototype vehicle, control system, and waste and water scavenging system were designed and fabricated with essentially the full capabilities of the vehicle system proposed by ARD Environmental. A test tank mockup, including riser and decontamination chamber were designed and fabricated, and approximately 830 cubic feet of six varieties of waste simulants poured. The tests were performed by ARD Environmental personnel at its site in Laurel, Maryland, from 4/22/97 through 5/2/97. The capabilities tested were deployment and retrieval, extended mobility and productivity, the ability to operate the system using video viewing only, retrieval after simulated failure, and retrieval and decontamination.more » Testing commenced with deployment of the vehicle into the tank. Deployment was accomplished using a crane and auxiliary winch to position the vehicle and lower it through the decontamination chamber, into the 36`` diameter x 6` high riser, and touch down on the waste field in the tank. The initial mobility tests were conducted immediately after deployment, prior to sluicing, as the waste field exhibited the greatest amount of variation at this time. This test demonstrated the ability of the vehicle to maneuver over the simulated waste field, and the ability of the operator to work with only video viewing available. In addition, the ability of the vehicle to right itself after being turned on its side was demonstrated. The production rate was evaluated daily through the testing period by measuring the surface and estimating the amount of material removed. The test demonstrated the ability of the vehicle to reduce the waste surface using 400 psi (nominal) water jets, scavenge water and material from the work area, and move to any location, even in the relatively confined space of the 20` diameter test tank. In addition, the ability to sluice to a remote scavenging module was demonstrated. The failure mode test demonstrated the ability to retrieve a stuck vehicle by pulling on the tether, even if the vehicle wheels were locked or the vehicle was on its side. Line pull required to retrieve the vehicle was measured, and side load on the riser calculated from the line pull and line angles. Finally, the decontamination test demonstrated the ability to effectively clean the umbilical and vehicle. The issues addressed and resolved during the testing were: Feasibility of deploying a vehicle- based system, mobility, production rate and limitation of water in the tank during sluicing, mining strategy, operator efficiency, vehicle recovery, and decontamination. Water usage and waste removal rates were used to estimate the time and water usage requirements for cleaning a Hanford SST.« less

  13. Towards the development of a rapid, portable, surface enhanced Raman spectroscopy based cleaning verification system for the drug nelarabine.

    PubMed

    Corrigan, Damion K; Salton, Neale A; Preston, Chris; Piletsky, Sergey

    2010-09-01

    Cleaning verification is a scientific and economic problem for the pharmaceutical industry. A large amount of potential manufacturing time is lost to the process of cleaning verification. This involves the analysis of residues on spoiled manufacturing equipment, with high-performance liquid chromatography (HPLC) being the predominantly employed analytical technique. The aim of this study was to develop a portable cleaning verification system for nelarabine using surface enhanced Raman spectroscopy (SERS). SERS was conducted using a portable Raman spectrometer and a commercially available SERS substrate to develop a rapid and portable cleaning verification system for nelarabine. Samples of standard solutions and swab extracts were deposited onto the SERS active surfaces, allowed to dry and then subjected to spectroscopic analysis. Nelarabine was amenable to analysis by SERS and the necessary levels of sensitivity were achievable. It is possible to use this technology for a semi-quantitative limits test. Replicate precision, however, was poor due to the heterogeneous drying pattern of nelarabine on the SERS active surface. Understanding and improving the drying process in order to produce a consistent SERS signal for quantitative analysis is desirable. This work shows the potential application of SERS for cleaning verification analysis. SERS may not replace HPLC as the definitive analytical technique, but it could be used in conjunction with HPLC so that swabbing is only carried out once the portable SERS equipment has demonstrated that the manufacturing equipment is below the threshold contamination level.

  14. Strip Coating Metrology on Large Scale Telescope Optics: Scalable Cost Saving Preventative Maintenance with First Contact Polymer

    NASA Astrophysics Data System (ADS)

    Hamilton, J.

    2012-09-01

    Protection and cleaning of precision optical surfaces on large scale astronomical instruments has entered a new era. First surface mirrors have been restored to "like-new" condition avoiding the expense and downtime of recoating. Nearly 10 years of testing and evaluation at a variety of sites including optics at Vandenberg Air Force Base, the Canada France Hawaii Telescope (CFHT) and the W.M Keck Telescope on Mauna Kea, have yielded impressive results: restored reflectivity, no residue, insitu cleaning and better coating performance when used as a precleaner when coating. Metrology and research in our labs has resulted in these novel, commercially available polymeric stripcoatings that are applied as a liquid and subsequently peeled off the substrate as a solid film. These designer polymer solutions safely clean and protect a wide variety of nanostructured surfaces and leave the surface almost atomically clean. Contaminant removal was monitored by a variety of techniques including Reflectivity, Nomarski, Atomic Force and Scanning Electron Microscopy as well as XPS. In addition, data demonstrates that the material safely removes particulate contamination and finger oils from nanostructures such as the 300nm wide lines on diffraction gratings and similar submicron features on Si wafers. High power laser damage testing found no residue on the optical surfaces following dried film removal and YAG laser damage thresholds after cleaning on coated BK7 of 15J/cm2 at 20ns and 20Hz were unchanged. Additionally to these adhesion tunable polymer systems, nanotube and graphene doped, ESD free polymer strip coatings for surface protection, nanoreplication, cleaning and dust mitigation have also been developed. Our coatings have been successfully used on diverse surfaces like high power laser optics, the Hope Diamond in Washington DC, CCD s for the 520 megapixel Dark Energy Survey Camera being built at Fermilab and lithographically fabbed detector surfaces for the Cryogenic Dark Matter Search.

  15. The Feasibility of Clean Intermittent Self-Catheterization Teaching in an Outpatient Setting.

    PubMed

    Bickhaus, Jennifer A; Drobnis, Erma Z; Critchlow, William A; Occhino, John A; Foster, Raymond T

    2015-01-01

    The aim of this study was to evaluate the feasibility of teaching clean intermittent self-catheterization (CISC) in an outpatient setting to women planning surgery for pelvic organ prolapse (POP) and/or urinary incontinence (UI). This was a prospective observational study of 55 women who planned surgical correction of POP and/or UI. All women were taught CISC as part of their preoperative education. The ability to learn CISC and the amount of time needed to teach CISC were recorded. Multivariate modeling, χ2 test, Fisher exact test, and Kruskal-Wallis analysis of variance were used for statistical analysis. Of the 55 subjects consecutively enrolled, 51 subjects (93%) were able to learn CISC and demonstrate competency (P < 0.00001). Four subjects (7%) were unable to learn CISC. The median time to teach CISC with demonstrated proficiency was 3.7 minutes (range, 1.8-7.4 minutes). Of the subjects who learned CISC and had surgery, the mean (SD) time in days from preoperative teaching to the postoperative voiding trial was 16 (11) days (range, 2-39 days). Of the 41 subjects who completed the postoperative voiding trial and had data recorded, 33 (80%) were able to self-catheterize without nurse assistance or with minimal verbal coaching, whereas 8 (20%) subjects required hands-on nursing assistance or were unable to perform CISC (P < 0.001). Clean intermittent self-catheterization can be taught to most patients undergoing POP/UI surgery in a short time (median, 3.7 minutes). The overwhelming majority of patients are able to retain the CISC skill weeks after being taught in the clinic.

  16. A design of experiments test to define critical spray cleaning parameters for Brulin 815 GD and Jettacin cleaners

    NASA Technical Reports Server (NTRS)

    Keen, Jill M.; Evans, Kurt B.; Schiffman, Robert L.; Deweese, C. Darrell; Prince, Michael E.

    1995-01-01

    Experimental design testing was conducted to identify critical parameters of an aqueous spray process intended for cleaning solid rocket motor metal components (steel and aluminum). A two-level, six-parameter, fractional factorial matrix was constructed and conducted for two cleaners, Brulin 815 GD and Diversey Jettacin. The matrix parameters included cleaner temperature and concentration, wash density, wash pressure, rinse pressure, and dishwasher type. Other spray parameters: nozzle stand-off, rinse water temperature, wash and rinse time, dry conditions, and type of rinse water (deionized) were held constant. Matrix response testing utilized discriminating bond specimens (fracture energy and tensile adhesion strength) which represent critical production bond lines. Overall, Jettacin spray cleaning was insensitive to the range of conditions tested for all parameters and exhibited bond strengths significantly above the TCA test baseline for all bond lines tested. Brulin 815 was sensitive to cleaning temperature, but produced bond strengths above the TCA test baseline even at the lower temperatures. Ultimately, the experimental design database was utilized to recommend process parameter settings for future aqueous spray cleaning characterization work.

  17. 19 CFR 151.65 - Duties.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.65 Duties. Duties on wool or hair... determination of clean yield. Estimated and liquidated duties on wool or hair tested for clean yield pursuant to... appropriate adjustment of the estimated percentage clean yield shown on the entry summary for the wool or hair...

  18. 19 CFR 151.65 - Duties.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.65 Duties. Duties on wool or hair... determination of clean yield. Estimated and liquidated duties on wool or hair tested for clean yield pursuant to... appropriate adjustment of the estimated percentage clean yield shown on the entry summary for the wool or hair...

  19. 19 CFR 151.65 - Duties.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.65 Duties. Duties on wool or hair... determination of clean yield. Estimated and liquidated duties on wool or hair tested for clean yield pursuant to... appropriate adjustment of the estimated percentage clean yield shown on the entry summary for the wool or hair...

  20. 19 CFR 151.65 - Duties.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.65 Duties. Duties on wool or hair... determination of clean yield. Estimated and liquidated duties on wool or hair tested for clean yield pursuant to... appropriate adjustment of the estimated percentage clean yield shown on the entry summary for the wool or hair...

  1. 19 CFR 151.65 - Duties.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.65 Duties. Duties on wool or hair... determination of clean yield. Estimated and liquidated duties on wool or hair tested for clean yield pursuant to... appropriate adjustment of the estimated percentage clean yield shown on the entry summary for the wool or hair...

  2. 75 FR 59973 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Control of Volatile...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-29

    ...; Cleaning of high precision optics; Stripping; Janitorial cleaning; cleaning of resin, coating, ink, and... laboratories; Cleaning operations in medical device or pharmaceutical manufacturing; and Cleaning operations related to performance or quality assurance testing of coatings, inks, or adhesives. COMAR 26.11.19.09-1...

  3. IMPROVED EQUIPMENT CLEANING IN COATED AND LAMINATED SUBSTRATE MANUFACTURING FACILITIES (PHASE I)

    EPA Science Inventory

    The report gives results of a Phase I study to characterize current equipment cleaning practices in the coated and laminated substrate manufacturing industry, to identify alternative cleaning technologies, and to identify demonstrable technologies and estimate their emissions imp...

  4. A robust, melting class bulk superhydrophobic material with heat-healing and self-cleaning properties

    PubMed Central

    Ramakrishna, S.; Santhosh Kumar, K. S.; Mathew, Dona; Reghunadhan Nair, C. P.

    2015-01-01

    Superhydrophobic (SH) materials are essential for a myriad of applications such as anti-icing and self-cleaning due to their extreme water repellency. A single, robust material simultaneously possessing melt-coatability, bulk water repellency, self-cleanability, self-healability, self-refreshability, and adhesiveness has been remaining an elusive goal. We demonstrate a unique class of melt-processable, bulk SH coating by grafting long alkyl chains on silica nanoparticle surface by a facile one-step method. The well-defined nanomaterial shows SH property in the bulk and is found to heal macro-cracks on gentle heating. It retains wettability characteristics even after abrading with a sand paper. The surface regenerates SH features (due to reversible self-assembly of nano structures) quickly at ambient temperature even after cyclic water impalement, boiling water treatment and multiple finger rubbing tests. It exhibits self-cleaning properties on both fresh and cut surfaces. This kind of coating, hitherto undisclosed, is expected to be a breakthrough in the field of melt-processable SH coatings. PMID:26679096

  5. ASRM process development in aqueous cleaning

    NASA Technical Reports Server (NTRS)

    Swisher, Bill

    1992-01-01

    Viewgraphs are included on process development in aqueous cleaning which is taking place at the Aerojet Advanced Solid Rocket Motor (ASRM) Division under a NASA Marshall Space and Flight Center contract for design, development, test, and evaluation of the ASRM including new production facilities. The ASRM will utilize aqueous cleaning in several manufacturing process steps to clean case segments, nozzle metal components, and igniter closures. ASRM manufacturing process development is underway, including agent selection, agent characterization, subscale process optimization, bonding verification, and scale-up validation. Process parameters are currently being tested for optimization utilizing a Taguci Matrix, including agent concentration, cleaning solution temperature, agitation and immersion time, rinse water amount and temperature, and use/non-use of drying air. Based on results of process development testing to date, several observations are offered: aqueous cleaning appears effective for steels and SermeTel-coated metals in ASRM processing; aqueous cleaning agents may stain and/or attack bare aluminum metals to various extents; aqueous cleaning appears unsuitable for thermal sprayed aluminum-coated steel; aqueous cleaning appears to adequately remove a wide range of contaminants from flat metal surfaces, but supplementary assistance may be needed to remove clumps of tenacious contaminants embedded in holes, etc.; and hot rinse water appears to be beneficial to aid in drying of bare steel and retarding oxidation rate.

  6. Optimization of Ultrasonic Fabric Cleaning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hand, T.E.

    The fundamental purpose of this project was to research and develop a process that would reduce the cost and improve the environmental efficiency of the present dry-cleaning industry. This second phase of research (see report KCP-94-1006 for information gathered during the first phase) was intended to allow the optimal integration of all factors of ultrasonic fabric cleaning. For this phase, Garment Care performed an extensive literature search and gathered data from other researchers worldwide. The Garment Care-AlliedSignal team developed the requirements for a prototype cleaning tank for studies and acquired that tank and the additional equipment required to use itmore » properly. Garment Care and AlliedSignal acquired the transducers and generators from Surftran Martin-Walter in Sterling Heights, Michigan. Amway's Kelly Haley developed the test protocol, supplied hundreds of test swatches, gathered the data on the swatches before and after the tests, assisted with the cleaning tests, and prepared the final analysis of the results. AlliedSignal personnel, in conjunction with Amway and Garment Care staff, performed all the tests. Additional planning is under way for future testing by outside research facilities. The final results indicated repeatable performance and good results for single layered fabric swatches. Swatches that were cleaned as a ''sandwich,'' that is, three or more layers.« less

  7. Digital cleaning and "dirt" layer visualization of an oil painting.

    PubMed

    Palomero, Cherry May T; Soriano, Maricor N

    2011-10-10

    We demonstrate a new digital cleaning technique which uses a neural network that is trained to learn the transformation from dirty to clean segments of a painting image. The inputs and outputs of the network are pixels belonging to dirty and clean segments found in Fernando Amorsolo's Malacañang by the River. After digital cleaning we visualize the painting's discoloration by assuming it to be a transmission filter superimposed on the clean painting. Using an RGB color-to-spectrum transformation to obtain the point-per-point spectra of the clean and dirty painting images, we calculate this "dirt" filter and render it for the whole image.

  8. The Search for Nonflammable Solvent Alternatives for Cleaning Aerospace Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Mitchell, Mark; Lowrey, Nikki

    2012-01-01

    Oxygen systems are susceptible to fires caused by particle and nonvolatile residue (NVR) contaminants, therefore cleaning and verification is essential for system safety. . Cleaning solvents used on oxygen system components must be either nonflammable in pure oxygen or complete removal must be assured for system safety. . CFC -113 was the solvent of choice before 1996 because it was effective, least toxic, compatible with most materials of construction, and non ]reactive with oxygen. When CFC -113 was phased out in 1996, HCFC -225 was selected as an interim replacement for cleaning propulsion oxygen systems at NASA. HCFC-225 production phase-out date is 01/01/2015. HCFC ]225 (AK ]225G) is used extensively at Marshall Space Flight Center and Stennis Space Center for cleaning and NVR verification on large propulsion oxygen systems, and propulsion test stands and ground support equipment. . Many components are too large for ultrasonic agitation - necessary for effective aqueous cleaning and NVR sampling. . Test stand equipment must be cleaned prior to installation of test hardware. Many items must be cleaned by wipe or flush in situ where complete removal of a flammable solvent cannot be assured. The search for a replacement solvent for these applications is ongoing.

  9. The effect of cleaning on blood contamination in the dental surgery following periodontal procedures.

    PubMed

    Edmunds, L M; Rawlinson, A

    1998-10-01

    Blood contamination of 16 surfaces in the dental surgery was investigated using the Kastle-Meyer test for haemoglobin, after three types of periodontal procedures had been performed on a total of 30 patients. The effect of cleaning surfaces contaminated by blood was investigated using the same test. Cleaning materials used in the dental surgery were tested to rule out the possibility of false positive outcomes and the sensitivity of the test was determined prior to the study. The results show a marked variation in the degree of contamination and efficacy of cleaning following treatment. Overall, root planing was associated with the most widespread and frequent blood contamination and gingival surgery the least. The surgery work surface, edge of the spittoon, aspirator tube and ultrasonic scaler handpiece into which the ultrasonic insert fits, were the most frequently contaminated surfaces. The work surface, dentist's pen, light switch and handle were cleaned most effectively. The least effectively cleaned surfaces were the water dispenser switch, aspirator tube, bracket table and ultrasonic scaler handpiece. Methods for reducing this potential source of cross-infection are discussed.

  10. A sturdy self-cleaning and anti-corrosion superhydrophobic coating assembled by amino silicon oil modifying potassium titanate whisker-silica particles

    NASA Astrophysics Data System (ADS)

    Lv, Chongjiang; Wang, Huaiyuan; Liu, Zhanjian; Zhang, Wenbo; Wang, Chijia; Tao, Ruifeng; Li, Meiling; Zhu, Yanji

    2018-03-01

    A sturdy self-cleaning and anticorrosion superhydrophobic coating based on poly(phenylene sulfide) (PPS) matrix has been successfully fabricated by combination of sol-gel and spraying technology without using any fluorine materials. The prepared coating possessed excellent superhydrophobicity with the water contact angle (WCA) (161 ± 1.2)° and slide angle (SA) (2 ± 1.5)°, which was ascribed to the synergistic effect of low-surface energy material amino silicon oil (ASO) and the binary potassium titanate whisker-silica (PTW-SiO2) composite particles formed by in-situ growth of SiO2 on modified PTW via sol-gel. Moreover, The PPS/ASO/PTW-SiO2 superhydrophobic coating exhibited decent self-cleaning property with clean surface even after 100 times immersion in muddy solution. The abrasion test demonstrated that the mechanical stability of prepared coating was about 2 times of the pure PPS coating. Simultaneously, the potentiodynamic polarization and electrochemical impedance spectroscopy testified the excellent corrosion resistance of prepared coating with the performance of lower corrosion current (1.289 × 10-10 A/cm2) and high protection efficiency (99.999%) even after immersion in 3.5 wt.% NaCl solution for 28 days. It is believed that this sturdy self-cleaning and anti-corrosion superhydrophobic coating might have a promising application prospect in industry.

  11. Physical cleaning by bubbly streaming flow in an ultrasound field

    NASA Astrophysics Data System (ADS)

    Yamashita, Tatsuya; Ando, Keita

    2017-11-01

    Low-intensity ultrasonic cleaning with gas-supersaturated water is a promising method of physical cleaning without erosion; we are able to trigger cavitation bubble nucleation by weak ultrasound under gas supersaturation and thus clean material surfaces by mild bubble dynamics. Here, we perform particle image velocimetry (PIV) measurement of liquid flow and cavitation bubble translation in an ultrasonic cleaning bath driven at 28 kHz and then relate it to cleaning tests using glass slides at which silica particles are attached. The ultrasound pressure amplitude at the cleaning spot is set at 1.4 atm. We select the supersaturation level of dissolved oxygen (DO) as a parameter and control it by oxygen microbubble aeration. It follows from the PIV measurement that the liquid flow is enhanced by the cavitation bubble translation driven by acoustic radiation force; this trend becomes clearer when the bubbles appear more densely as the DO supersaturation increases. In the cleaning tests, the cleaned areas appear as straight streaks. This suggests that physical cleaning is achieved mainly by cavitation bubbles that translate in ultrasound fields.

  12. Demonstration Of A Nanomaterial-Modified Primer For Use In Corrosion-Inhibiting Coating Systems

    DTIC Science & Technology

    2011-11-01

    abrasive blasting or other means. This report documents the materials and methodologies used for testing and application of the new coating systems on the...method with improved corrosion resistant coatings will provide the DoD with a means to cost effectively rehabilitate the outer metal surfaces of...contained with environmental controls in place. ........................................ 9 Figure 6. Abrasive blast-cleaned tank surface

  13. Bio-Inspired Self-Cleaning Surfaces

    NASA Astrophysics Data System (ADS)

    Liu, Kesong; Jiang, Lei

    2012-08-01

    Self-cleaning surfaces have drawn a lot of interest for both fundamental research and practical applications. This review focuses on the recent progress in mechanism, preparation, and application of self-cleaning surfaces. To date, self-cleaning has been demonstrated by the following four conceptual approaches: (a) TiO2-based superhydrophilic self-cleaning, (b) lotus effect self-cleaning (superhydrophobicity with a small sliding angle), (c) gecko setae-inspired self-cleaning, and (d) underwater organisms-inspired antifouling self-cleaning. Although a number of self-cleaning products have been commercialized, the remaining challenges and future outlook of self-cleaning surfaces are also briefly addressed. Through evolution, nature, which has long been a source of inspiration for scientists and engineers, has arrived at what is optimal. We hope this review will stimulate interdisciplinary collaboration among material science, chemistry, biology, physics, nanoscience, engineering, etc., which is essential for the rational design and reproducible construction of bio-inspired multifunctional self-cleaning surfaces in practical applications.

  14. Performance degradation and cleaning of photovoltaic arrays

    NASA Technical Reports Server (NTRS)

    Sheskin, T. J.; Chang, G. C.; Cull, R. C.; Knapp, W. D.

    1982-01-01

    NASA tests results from an 18 mo program of cleaning silicone-encapsulated and glass fronted solar cell panels in urban and desert environments to examine the effects of cleaning on module performance are reported. The panels were cleaned on weekly, monthly, quarterly, or semi-annual basis, while other panels of the same construction were not cleaned and served as controls. Commercially-available detergents and city water were employed for the tests, and the measurements were maintained of the modules' continuing short-circuit current output. The decay of the output was determined by least square regression analyses. Performance degradation was noticeably less in glass covered, rather than silicone-encapsulated modules which decayed faster in urban than in desert environments. Lower frequency cleanings are recommended where labor costs are high.

  15. Development flight tests of JetStar LFC leading-edge flight test experiment

    NASA Technical Reports Server (NTRS)

    Fisher, David F.; Fischer, Michael C.

    1987-01-01

    The overall objective of the flight tests on the JetStar aircraft was to demonstrate the effectiveness and reliability of laminar flow control under representative flight conditions. One specific objective was to obtain laminar flow on the JetStar leading-edge test articles for the design and off-design conditions. Another specific objective was to obtain operational experience on a Laminar Flow Control (LFC) leading-edge system in a simulated airline service. This included operational experience with cleaning requirements, the effect of clogging, possible foreign object damage, erosion, and the effects of ice particle and cloud encounters. Results are summarized.

  16. Life of Pennzane and 815Z-Lubricated Instrument Bearings Cleaned with Non-CFC Solvents

    NASA Technical Reports Server (NTRS)

    Loewenthal, Stuart H.; Jones, William R., Jr.; Predmore, Roamer E.

    1999-01-01

    Life tests were conducted on instrument scanner ball bearings cleaned with 3 types of non-ozone depleting solvents and compared with those cleaned with a conventional CFC-113 (Freon) solvent. The test bearings were lubricated with the standard space oil (Bray 815Z, Fomblin Z25) and a more recent synthetic space oil (Pennzane 2001). Lives with replacement solvents equaled or exceeded those obtained with CFC-113 baseline, indicating that alternate cleaning solvents were acceptable. Pennzane lubricated bearings enjoyed a significant life advantage (>5X) over those lubricated with Bray 815Z oil in these oscillatory gimbal bearing tests. Many of the Pennzane bearings are still exhibiting acceptable torque traces after more than 25,000 hr of test.

  17. Social ranking effects on tooth-brushing behaviour.

    PubMed

    Maltby, John; Paterson, Kevin; Day, Liz; Jones, Ceri; Kinnear, Hayley; Buchanan, Heather

    2016-05-01

    A tooth-brushing social rank hypothesis is tested suggesting tooth-brushing duration is influenced when individuals position their behaviour in a rank when comparing their behaviour with other individuals. Study 1 used a correlation design, Study 2 used a semi-experimental design, and Study 3 used a randomized intervention design to examine the tooth-brushing social rank hypothesis in terms of self-reported attitudes, cognitions, and behaviour towards tooth-brushing duration. Study 1 surveyed participants to examine whether the perceived health benefits of tooth-brushing duration could be predicted from the ranking of each person's tooth-brushing duration. Study 2 tested whether manipulating the rank position of the tooth-brushing duration influenced participant-perceived health benefits of tooth-brushing duration. Study 3 used a longitudinal intervention method to examine whether messages relating to the rank positions of tooth-brushing durations causally influenced the self-report tooth-brushing duration. Study 1 demonstrates that perceptions of the health benefits from tooth-brushing duration are predicted by the perceptions of how that behaviour ranks in comparison to other people's behaviour. Study 2 demonstrates that the perceptions of the health benefits of tooth-brushing duration can be manipulated experimentally by changing the ranked position of a person's tooth-brushing duration. Study 3 experimentally demonstrates the possibility of increasing the length of time for which individuals clean their teeth by focusing on how they rank among their peers in terms of tooth-brushing duration. The effectiveness of interventions using social-ranking methods relative to those that emphasize comparisons made against group averages or normative guidelines are discussed. What is already known on this subject? Individual make judgements based on social rank information. Social rank information has been shown to influence positive health behaviours such as exercise. What does this study add? The health benefits of tooth-brushing are predicted by how tooth-brushing duration ranks within a distribution. Focussing on how teeth-cleaning duration ranks among others produces longer teeth-cleaning durations. © 2015 The British Psychological Society.

  18. Brush head composition, wear profile, and cleaning efficacy: an assessment of three electric brush heads using in vitro methods.

    PubMed

    Kaiser, Eva; Meyners, Michael; Markgraf, Dirk; Stoerkel, Ulrich; von Koppenfels, Roxana; Adam, Ralf; Soukup, Martin; Wehrbein, Heinrich; Erbe, Christina

    2014-01-01

    The objective of this research was to evaluate a current store brand (SB) brush head for composition/physical characteristics, Wear Index (WI), and cleaning efficacy versus the previous SB brush head refill design (SB control) and the Oral-B Precision Clean brush head (positive control, PC). This research consisted of three parts: 1) Analytical analysis using Fourier Transform Infrared (FT-IR) spectrometry to evaluate the chemical composition of the current SB brush head bristles relative to the SB control. In addition, physical parameters such as bristle count and diameter were determined. 2) Wear Index (WI) investigation to determine the Wear Index scores of in vitro-aged brush heads at four weeks (one month) and 13 weeks (three months) by a trained investigator. To "age" the brush heads, a robot system was used as a new alternative in vitro method to simulate aging by consumer use. 3) Robot testing to determine the cleaning performance of in vitro-aged brush heads, comparing one month-aged current SB brush heads with the SB control (one and three months-aged) and the PC brush heads (three months-aged) in a standardized fashion. 1) FT-IR analysis revealed that the chemical composition of the current and control SB refill brush heads is identical. In terms of physical parameters, the current SB brush head has 12% more bristles and a slightly oval brush head compared to the round brush head of the SB control. 2) Wear Index analysis showed there was no difference in the one month-aged current SB brush head versus the one month-aged SB control (1.67 vs. 1.50, p = 0.65) or versus the three months-aged PC brush head (1.67 vs. 1.50, p = 0.65). The one month-aged current SB brush head demonstrated statistically significantly less wear than the three months-aged SB control (1.67 vs. 2.67, p = 0.01). 3) Analysis of cleaning efficacy shows that the one month-aged current SB brush head had improved cleaning performance over the one month-aged SB control brush head (p < 0.05), despite no statistically significant difference in wear. Both the one month-aged current and control SB brush heads showed statistically significantly lower cleaning performance compared to the three months-aged PC brush heads (p < 0.01). While the current SB brush head showed improved cleaning over the SB control, it demonstrated significantly lower durability and cleaning in comparison to the PC brush head. Dental professionals should be aware of these differences, both in durability and in cleaning performance, when recommending brush heads to their patients.

  19. Quantitative cleaning characterization of a lithium-fluoride ion diode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menge, P.R.; Cuneo, M.E.

    An ion source cleaning testbed was created to test plasma-cleaning techniques, and to provide quantitative data on plasma-cleaning protocols prior to implementation on the SABRE accelerator. The testbed was designed to resolve issues regarding the quantity of contaminants absorbed by the anode source (LiF), and the best cleaning methodology. A test chamber was devised containing a duplicate of the SABRE diode. Radio-frequency (RF) power was fed to the anode, which was isolated from ground and thus served as the plasma discharge electrode. RF plasma discharges in 1--3 mtorr of Ar with 10% O{sub 2} were found to provide the bestmore » cleaning of the LiF surface. X-ray photoelectron spectroscopy (XPS) showed that the LiF could accrue dozens of monolayers of carbon just by sitting in a 2 {times} 10{sup {minus}5} vacuum for 24 h. Tests of various discharge cleaning protocols indicated that 15 min of an Ar/O{sub 2} discharge was sufficient to reduce this initial 13--45 monolayers of carbon impurities to 2--4 monolayers. Rapid recontamination of the LiF was also observed. Up to ten monolayers of carbon returned in 2 min after termination of the plasma discharge and subsequent pumping back to the 10{sup {minus}5} torr range. Heating of the LiF also was found to provide anode cleaning. Application of heating combined with plasma cleaning provided the highest cleaning rates.« less

  20. Precision Cleaning of Oxygen Systems and Components

    NASA Technical Reports Server (NTRS)

    McLaughlin, Russell

    2009-01-01

    Currently, NASA uses Dichloropentafluoropropane (HCFC-225), a Class II ozone depleting substance (ODs), to clean contaminated oxygen systems. Starting in 20 15, the Montreal Protocols and Clean Air Act prohibit the production and importation of all hydrochlorofluorocarbons (HCFC), except for limited use in refrigeration applications. Thus, a new non-ozone depleting solvent needs to be developed for use in cleaning. Optimally, such a solvent should also be environmentally benign or green to avoid needing to replace the new solvent with yet another solvent in the future due to other environmental concerns. Work for the first year consisted of two parts. The first part was developing a method of testing the cleaning efficiency of potential solvents. Stainless steel coupons were contaminated with a known weight of various contaminants and contaminant combinations and then immersed in solvent for ten minutes. The coupons were then removed and dried in an oven until all solvent had evaporated. Once dry, the coupons were weighed and the mass of the non-volatile residue (NVR) left on the coupon was determined. The cleaning efficiency of the solvents is reported as percent cleaning, with 100% cleaning being zero NVR left on the test coupon. The second half of the first goal was to use the develop method to perform baseline testing on current solvents. The second part of the work was to begin exploring alternative cleaning solvents. A variety of hydrofluorocarbons (HFCs) were tested. Preliminary testing was also performed with ionic liquids and aqueous surfactant solutions. Once potential solvents were identified, an analysis of the performance and environmental characteristics of each was to be conducted. Four contaminants were specified for use in testing. These are Mil-Spec-H-5606 (5606), a hydraulic fluid, Mil-H-83282B (83282), another hydraulic fluid, diethylhexyl sebacate (Sebacate), and WD-40. The structures of these contaminants are all similar, with long aliphatic hydrocarbon chains of lengths between fifteen and fifty. Contaminants were tested both individually and in combination. All combinations were done with equal weights of the constituent contaminants.

  1. Annual Report, Fall 2016: Alternative Chemical Cleaning of Radioactive High Level Waste Tanks - Corrosion Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wyrwas, R. B.

    The testing presented in this report is in support of the investigation of the Alternative Chemical Cleaning program to aid in developing strategies and technologies to chemically clean radioactive High Level Waste tanks prior to tank closure. The data and conclusions presented here were the examination of the corrosion rates of A285 carbon steel and 304L stainless steel exposed to two proposed chemical cleaning solutions: acidic permanganate (0.18 M nitric acid and 0.05M sodium permanganate) and caustic permanganate. (10 M sodium hydroxide and 0.05M sodium permanganate). These solutions have been proposed as a chemical cleaning solution for the retrieval ofmore » actinides in the sludge in the waste tanks, and were tested with both HM and PUREX sludge simulants at a 20:1 ratio.« less

  2. A Miniature Wastewater Cleaning Plant to Demonstrate Primary Treatment in the Classroom

    ERIC Educational Resources Information Center

    Ne´el, Bastien; Cardoso, Catia; Perret, Didier; Bakker, Eric

    2015-01-01

    A small-scale wastewater cleaning plant is described that includes the key physical pretreatment steps followed by the chemical treatment of mud by flocculation. Water, clay particles, and riverside deposits mimicked odorless wastewater. After a demonstration of the optimization step, the flocculation process was carried out with iron(III)…

  3. Environmentally compatible hand wipe cleaning solvents

    NASA Technical Reports Server (NTRS)

    Clayton, Catherine P.; Kovach, Michael P.

    1995-01-01

    Several solvents of environmental concern have previously been used for hand wipe cleaning of SRB surfaces, including 1,1,1-trichloroethane, perchloroethylene, toluene, xylene, and MEK. USBI determined the major types of surfaces involved, and qualification requirements of replacement cleaning agents. Nineteen environmentally compatible candidates were tested on 33 material substrates with 26 types of potential surface contaminants, involving over 7,000 individual evaluations. In addition to the cleaning performance evaluation, bonding, compatibility, and corrosion tests were conducted. Results showed that one cleaner was not optimum for all surfaces. In most instances, some of the candidates cleaned better than the 1,1,1-trichloroethane baseline control. Aqueous cleaners generally cleaned better, and were more compatible with nonmetallic materials, such as paints, plastics, and elastomers. Organic base cleaners were better on metal surfaces. Five cleaners have been qualified and are now being implemented in SRB hand wipe cleaning operations.

  4. Development of environmentally conscious cleaning process for leadless chip carrier assemblies. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, B.E.

    1995-04-01

    A cross-functional team of process, product, quality, material, and design lab engineers was assembled to develop an environmentally friendly cleaning process for leadless chip carrier assemblies (LCCAs). Using flush and filter testing, Auger surface analysis, GC-Mass spectrophotometry, production yield results, and electrical testing results over an extended testing period, the team developed an aqueous cleaning process for LCCAs. The aqueous process replaced the Freon vapor degreasing/ultrasonic rinse process.

  5. Use of 90% ethanol to decontaminate stethoscopes in resource limited settings.

    PubMed

    Raghubanshi, Bijendra Raj; Sapkota, Supriya; Adhikari, Arjab; Dutta, Aman; Bhattarai, Utsuk; Bhandari, Rastriyata

    2017-01-01

    In developing countries like Nepal, 90% ethanol is cheap and is available in most hospitals. The unavailability of isopropyl alcohol (IPA) in these settings led us to compare the efficacy between 90% ethanol and isopropyl alcohol pads in reducing the bacterial contamination of diaphragm of stethoscope. A randomized blinded experimental study was carried out to determine the difference between cleaning stethoscopes with 90% ethanol and IPA. Cultures of diaphragm were taken before and after cleaning with one of the cleaning agent. Colony forming units (CFU) count and organism identification was done by a blinded investigator. CFU before and after cleaning were compared using Wilcoxon signed-rank test. Mann Whitney U test was used to compare the decrease in CFU count between the cleaning agents. About 30% of the stethoscopes harbored potential pathogens. Significant reduction in CFU was observed with both IPA (Wilcoxon signed-rank test, P value <0.001) and 90% ethanol (Wilcoxon signed-rank test, P value <0.001). Comparing median decrease in CFU between cleaning with IPA and with 90% ethanol, no significant difference was found (Mann Whitney U test; U = 1357, P value >0.05). Both 90% ethanol and IPA are equally effective in decontaminating the diaphragm of stethoscope. Selection of agent should be done on the basis of cost and availability.

  6. Alternative Chemical Cleaning Methods for High Level Waste Tanks: Actual Waste Testing with SRS Tank 5F Sludge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, William D.; Hay, Michael S.

    Solubility testing with actual High Level Waste tank sludge has been conducted in order to evaluate several alternative chemical cleaning technologies for the dissolution of sludge residuals remaining in the tanks after the exhaustion of mechanical cleaning and sludge sluicing efforts. Tests were conducted with archived Savannah River Site (SRS) radioactive sludge solids that had been retrieved from Tank 5F in order to determine the effectiveness of an optimized, dilute oxalic/nitric acid cleaning reagent toward dissolving the bulk non-radioactive waste components. Solubility tests were performed by direct sludge contact with the oxalic/nitric acid reagent and with sludge that had beenmore » pretreated and acidified with dilute nitric acid. For comparison purposes, separate samples were also contacted with pure, concentrated oxalic acid following current baseline tank chemical cleaning methods. One goal of testing with the optimized reagent was to compare the total amounts of oxalic acid and water required for sludge dissolution using the baseline and optimized cleaning methods. A second objective was to compare the two methods with regard to the dissolution of actinide species known to be drivers for SRS tank closure Performance Assessments (PA). Additionally, solubility tests were conducted with Tank 5 sludge using acidic and caustic permanganate-based methods focused on the “targeted” dissolution of actinide species.« less

  7. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  8. Histoplasma skin test

    MedlinePlus

    Histoplasmosis skin test ... health care provider cleans an area of your skin, usually the forearm. An allergen is injected just below the cleaned skin surface. An allergen is a substance that causes ...

  9. In vitro and in vivo corrosion evaluation of nickel-chromium- and copper-aluminum-based alloys.

    PubMed

    Benatti, O F; Miranda, W G; Muench, A

    2000-09-01

    The low resistance to corrosion is the major problem related to the use of copper-aluminum alloys. This in vitro and in vivo study evaluated the corrosion of 2 copper-aluminum alloys (Cu-Al and Cu-Al-Zn) compared with a nickel-chromium alloy. For the in vitro test, specimens were immersed in the following 3 corrosion solutions: artificial saliva, 0.9% sodium chloride, and 1.0% sodium sulfide. For the in vivo test, specimens were embedded in complete dentures, so that one surface was left exposed. The 3 testing sites were (1) close to the oral mucosa (partial self-cleaning site), (2) surface exposed to the oral cavity (self-cleaning site), and (3) specimen bottom surface exposed to the saliva by means of a tunnel-shaped perforation (non-self-cleaning site). Almost no corrosion occurred with the nickel-chromium alloy, for either the in vitro or in vivo test. On the other hand, the 2 copper-aluminum-based alloys exhibited high corrosion in the sulfide solution. These same alloys also underwent high corrosion in non-self-cleaning sites for the in vivo test, although minimal attack was observed in self-cleaning sites. The nickel-chromium alloy presented high resistance to corrosion. Both copper-aluminum alloys showed considerable corrosion in the sulfide solution and clinically in the non-self-cleaning site. However, in self-cleaning sites these 2 alloys did not show substantial corrosion.

  10. Heart of the Hearth: Making the Popular Clean, Not the Clean Popular - Technology Research, Development, and Tools for Clean Biomass Cookstoves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gist, Ryan

    This technical report summarizes the work completed by BioLite in fulfilment of the US DOE EERE award. The work plan focused on three key objectives: developing an optimized combustion system that demonstrates high combustion efficiency and low PM 2.5 and CO emissions, integrate the system into popular stove phenotypes – side-fed rocket stove architecture like the BioLite HomeStove, and the Patsari chimney stove in Mexico such that they maintain their important phenotypical characteristics, independently evaluate quantitative fuel and emissions performance of the integrated ‘Turbo-Patsari’ in Mexican households. The project activities were organized into six major tasks: A. Develop, fabricate, andmore » test proof-of-concept prototypes B. Develop field prototypes, assess user feedback and field performance C. Define revised stove design for pre-production model, Identify manufacturing requirements and estimated cost to build, Conduct reliability, emissions, and performance testing of pre-production Turbo-Patsari D. Build pre-production Turbo-Patsari stove combustion cores E. Conduct pre-production field trials F. Summarize field trial results and evaluate Turbo-Patsari for potential volume production. A two-pronged approach was adopted for the above tasks. The first involved building a modular test platform that allowed parametric variation of multiple stove design parameters that directly affect its performance – heat output, thermal efficiency, and emissions. The second part of the approach comprised of building a surrogate Patsari based on GIRA’s specifications that could then be modified or retrofitted for optimum performance based on the learnings from the modular test platform. The following sections of the report will describe the findings of tests on these platform, the subsequent development, design, and installation of the Turbo-Patsari, and finally the in-home field trial.« less

  11. Cluster Development Test 2: An Assessment of a Failed Test

    NASA Technical Reports Server (NTRS)

    Machin, Ricardo A.; Evans, Carol T.

    2009-01-01

    On 31 July 2008 the National Aeronautics and Space Administration Crew Exploration Vehicle Parachute Assembly System team conducted the final planned cluster test of the first generation parachute recovery system design. The two primary test objectives were to demonstrate the operation of the complete parachute system deployed from a full scale capsule simulator and to demonstrate the test technique of separating the capsule simulator from the Low Velocity Air Drop pallet used to extract the test article from a United States Air Force C-17 aircraft. The capsule simulator was the Parachute Test Vehicle with an accurate heat shield outer mold line and forward bay compartment of the Crew Exploration Vehicle Command Module. The Parachute Test Vehicle separated cleanly from the pallet following extraction, but failed to reach test conditions resulting in the failure of the test and the loss of the test assets. No personnel were injured. This paper will discuss the design of the test and the findings of the team that investigated the test, including a discussion of what were determined to be the root causes of the failure.

  12. A study of visual and blood contamination on reprocessed endodontic files from general dental practice.

    PubMed

    Letters, S; Smith, A J; McHugh, S; Bagg, J

    2005-10-22

    This study examined methods used for reprocessing endodontic instruments in general dental practice and determined the degree of residual visual contamination and blood contamination on 250 reprocessed files collected from 25 general dental practices. A questionnaire was administered to 25 general dental practitioners to obtain information on the re-processing of used endodontic files. Ten files which had been used and reprocessed were also collected from each practice. These were examined visually under a dissecting light microscope for residual contamination and then tested for blood deposits using the Kastle-Meyer test. Nineteen of the 25 practices used stainless steel hand files. No practitioners used endodontic files as single use devices. Ninety-two per cent of the practitioners discarded and replaced files when they were bent or damaged. Several decontamination methods were reported. The two combinations employed most frequently were manual cleaning and autoclaving or manual cleaning, followed by ultrasonic cleaning and autoclaving. Of the 250 files, 75% showed some degree of visual contamination and seven percent tested positive for residual blood. Blood contaminated files were significantly more heavily contaminated when examined visually. Large variations were found in residual contamination of files collected from practices using the same methods of decontamination. While all practitioners re-used endodontic files, the variations in decontamination methods reported indicate a lack of clarity on best practice. This study demonstrates that endodontic files are not reliably decontaminated by methods currently employed in dental practice.

  13. Laser-induced contamination control for high-power lasers in space-based LIDAR missions

    NASA Astrophysics Data System (ADS)

    Alves, Jorge; Pettazzi, Federico; Tighe, Adrian; Wernham, Denny

    2017-11-01

    In the framework of the ADM-Aeolus satellite mission, successful test campaigns have been performed in ESTEC's laser laboratory, and the efficiency of several mitigation techniques against Laser-Induced Contamination (LIC) have been demonstrated for the ALADIN laser. These techniques include the standard contamination control methods of materials identification with particular tendency to cause LIC, reduction of the outgassing of organic materials by vacuum bake-out and shielding of optical surfaces from the contamination sources. Also novel mitigation methods such as in-situ cleaning via partial pressures, or the usage of molecular absorbers were demonstrated. In this context, a number of highly sensitive optical measurement techniques have been developed and tested to detect and monitor LIC deposits at nanometre level.

  14. Geothermal down well pumping system

    NASA Technical Reports Server (NTRS)

    Matthews, H. B.; Mcbee, W. D.

    1974-01-01

    A key technical problem in the exploitation of hot water geothermal energy resources is down-well pumping to inhibit mineral precipitation, improve thermal efficiency, and enhance flow. A novel approach to this problem involves the use of a small fraction of the thermal energy of the well water to boil and super-heat a clean feedwater flow in a down-hole exchanger adjacent to the pump. This steam powers a high-speed turbine-driven pump. The exhaust steam is brought to the surface through an exhaust pipe, condensed, and recirculated. A small fraction of the high-pressure clean feedwater is diverted to lubricate the turbine pump bearings and prevent leakage of brine into the turbine-pump unit. A project demonstrating the feasibility of this approach by means of both laboratory and down-well tests is discussed.

  15. Replacement Technologies for Precision Cleaning of Aerospace Hardware for Propellant Service

    NASA Technical Reports Server (NTRS)

    Beeson, Harold; Kirsch, Mike; Hornung, Steven; Biesinger, Paul

    1997-01-01

    The NASA White Sands Test Facility (WSTF) is developing cleaning and verification processes to replace currently used chlorofluorocarbon-l13- (CFC-113-) based processes. The processes being evaluated include both aqueous- and solvent-based techniques. Replacement technologies are being investigated for aerospace hardware and for gauges and instrumentation. This paper includes the findings of investigations of aqueous cleaning and verification of aerospace hardware using known contaminants, such as hydraulic fluid and commonly used oils. The results correlate nonvolatile residue with CFC 113. The studies also include enhancements to aqueous sampling for organic and particulate contamination. Although aqueous alternatives have been identified for several processes, a need still exists for nonaqueous solvent cleaning, such as the cleaning and cleanliness verification of gauges used for oxygen service. The cleaning effectiveness of tetrachloroethylene (PCE), trichloroethylene (TCE), ethanol, hydrochlorofluorocarbon 225 (HCFC 225), HCFC 141b, HFE 7100(R), and Vertrel MCA(R) was evaluated using aerospace gauges and precision instruments and then compared to the cleaning effectiveness of CFC 113. Solvents considered for use in oxygen systems were also tested for oxygen compatibility using high-pressure oxygen autogenous ignition and liquid oxygen mechanical impact testing.

  16. Quiet Clean Short-haul Experimental Engine (QCSEE) clean combustor test report

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A component pressure test was conducted on a F101 PFRT combustor to evaluate the emissions levels of this combustor design at selected under the wing and over the wing operating conditions for the quiet clean short haul experimental engine (QCSEE). Emissions reduction techniques were evaluated which included compressor discharge bleed and sector burning in the combustor. The results of this test were utilized to compare the expected QCSEE emissions levels with the emission goals of the QCSEE engine program.

  17. An overview of NASA testing requirements for alternate cleaning solvents used in liquid and gaseous oxygen environments

    NASA Technical Reports Server (NTRS)

    Strickland, John W.; Davis, S. Eddie

    1995-01-01

    The elimination of CFC-containing cleaning solvents for oxygen systems has prompted the development of a number of alternative cleaning solvents that must now be evaluated not only for cleanability, but compatibility as well. NASA Handbook 8060.1(NHB 8060.1) establishes the requirements for evaluation, testing, and selection of materials for use in oxygen rich environments. Materials intended for use in space vehicles, specified test facilities, and ground support equipment must meet the requirements of this document. In addition to the requirements of NHB 8060.1 for oxygen service, alternative cleaning solvents must also be evaluated in other areas (such as corrosivity, non-metals compatibility, non-volatile residue contamination, etc.). This paper will discuss the testing requirements of NHB 8060.1 and present preliminary results from early screening tests performed at Marshall Space Flight Center's Materials Combustion Research Facility.

  18. Adenosine triphosphate bioluminescence for bacteriological surveillance and reprocessing strategies for minimizing risk of infection transmission by duodenoscopes

    PubMed Central

    Sethi, Saurabh; Huang, Robert J.; Barakat, Monique T.; Banaei, Niaz; Friedland, Shai; Banerjee, Subhas

    2017-01-01

    Background/Aims Recent outbreaks of duodenoscope-transmitted infections underscore the importance of adequate endoscope reprocessing. Adenosine triphosphate (ATP) bioluminescence testing allows rapid evaluation of endoscopes for bacteriological/biological residue. In this prospective study we evaluate the utility of ATP in bacteriological surveillance, and the effects of endoscopy staff education and dual cycles of cleaning and high-level disinfection (HLD) on endoscope reprocessing. Methods ATP bioluminescence was measured after pre-cleaning, manual cleaning and HLD on rinsates from suction-biopsy channels of all endoscopes and elevator channels of duodenoscopes/linear echoendoscopes after use. ATP bioluminescence was re-measured in duodenoscopes (1) after re-education and competency testing of endoscopy staff, and subsequently (2) after 2 cycles of pre-cleaning and manual cleaning and single cycle of HLD, or (3) after 2 cycles of pre-cleaning, manual cleaning and HLD. Results The ideal ATP bioluminescence benchmark of <200 relative light units (RLUs) after manual cleaning was achieved from suction-biopsy channel rinsates of all endoscopes, but 9 of 10 duodenoscope elevator channel rinsates failed to meet this benchmark. Re-education reduced RLUs in duodenoscope elevator channel rinsates after pre-cleaning (23218.0 vs 1340.5 RLUs, p<0.01) and HLD (177.0 vs 12.0 RLUs, p<0.01). After 2 cycles of manual cleaning/HLD, duodenoscope elevator channel RLUs achieved levels similar to sterile water, with corresponding negative cultures. Conclusions ATP testing offers a rapid, inexpensive alternative for detection of endoscope microbial residue. Re-education of endoscopy staff and 2 cycles of cleaning and HLD decrease elevator channel RLUs to levels similar to sterile water and may therefore minimize the risk of transmission of infections by duodenoscopes. PMID:27818222

  19. Coal-cleaning plant refuse characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cavalet, J.R.; Torak, E.R.

    1985-06-01

    This report describes a study performed for the Electric Power Research Institute's Coal Cleaning Test Facility in Homer City, Pennsylvania. The purpose of the study was to design a standard methods for chemically and physically classifying refuse generated by physical coal cleaning and to construct a matrix that will accurately predict how a particular refuse will react to particular disposal methods - based solely on raw-coal characteristics and the process used to clean the coal. The value of such a classification system (which has not existed to this point) is the ability to design efficient and economical systems for disposingmore » of specific coal cleaning refuse. The report describes the project's literature search and a four-tier classification system. It also provides designs for test piles, sampling procedures, and guidelines for a series of experiments to test the classfication system and create an accurate, reliable predictive matrix. 38 refs., 39 figs., 35 tabs.« less

  20. ENHANCED CHEMICAL CLEANING: A NEW PROCESS FOR CHEMICALLY CLEANING SAVANNAH RIVER WASTE TANKS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ketusky, E; Neil Davis, N; Renee Spires, R

    2008-01-17

    The Savannah River Site (SRS) has 49 high level waste (HLW) tanks that must be emptied, cleaned, and closed as required by the Federal Facilities Agreement. The current method of chemical cleaning uses several hundred thousand gallons per tank of 8 weight percent (wt%) oxalic acid to partially dissolve and suspend residual waste and corrosion products such that the waste can be pumped out of the tank. This adds a significant quantity of sodium oxalate to the tanks and, if multiple tanks are cleaned, renders the waste incompatible with the downstream processing. Tank space is also insufficient to store thismore » stream given the large number of tanks to be cleaned. Therefore, a search for a new cleaning process was initiated utilizing the TRIZ literature search approach, and Chemical Oxidation Reduction Decontamination--Ultraviolet (CORD-UV), a mature technology currently used for decontamination and cleaning of commercial nuclear reactor primary cooling water loops, was identified. CORD-UV utilizes oxalic acid for sludge dissolution, but then decomposes the oxalic acid to carbon dioxide and water by UV treatment outside the system being treated. This allows reprecipitation and subsequent deposition of the sludge into a selected container without adding significant volume to that container, and without adding any new chemicals that would impact downstream treatment processes. Bench top and demonstration loop measurements on SRS tank sludge stimulant demonstrated the feasibility of applying CORD-UV for enhanced chemical cleaning of SRS HLW tanks.« less

  1. MSG test report: removal of residual sodium. [LMFBR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harty, R.B.

    1974-03-08

    This report presents the results of cleaning activities performed to remove residual sodium from the AI Modular Steam Generator. A description of the cleaning loop, cleaning procedure, results, and visual inspection are included.

  2. Contamination removal using various solvents and methodologies

    NASA Technical Reports Server (NTRS)

    Jeppsen, J. C.

    1989-01-01

    Critical and non-critical bonding surfaces must be kept free of contamination that may cause potential unbonds. For example, an aft-dome section of a redesigned solid rocket motor that had been contaminated with hydraulic oil did not appear to be sufficiently cleaned when inspected by the optically stimulated electron emission process (Con Scan) after it had been cleaned using a hand double wipe cleaning method. As a result, current and new cleaning methodologies as well as solvent capability in removing various contaminant materials were reviewed and testing was performed. Bonding studies were also done to verify that the cleaning methods used in removing contaminants provide an acceptable bonding surface. The removal of contaminants from a metal surface and the strength of subsequent bonds were tested using the Martin Marietta and double-wipe cleaning methods. Results are reported.

  3. Depletion of liver glutathione levels in rats: a potential confound of nose-only inhalation.

    PubMed

    Fechter, Laurence D; Nelson-Miller, Alisa; Gearhart, Caroline

    2008-07-01

    Nose-only inhalation exposure chambers offer key advantages to whole-body systems, particularly when aerosol or mixed aerosol-vapor exposures are used. Specifically, nose-only chambers provide enhanced control over the route of exposure and dose by minimizing the deposition of particles either on the subjects skin/fur or on surfaces of a whole-body exposure system. In the current series of experiments, liver, brain, and lung total glutathione (GSH) levels were assessed following either nose-only or whole-body exposures to either jet fuel or to clean, filtered air. The data were compared to untreated control subjects. Acute nose-only inhalation exposures of rats resulted in a significant depletion of liver GSH levels both in subjects that were exposed to clean, filtered air as well as those exposed to JP-8 jet fuel and to a synthetic jet fuel. Glutathione levels were not altered in lung or brain tissue. Whole-body inhalation exposure had no effect on GSH levels in any tissue for any of the treatment groups. A second experiment demonstrated that the loss of GSH did not occur if rats were anaesthetized prior to and during nose-only exposure to clean, filtered air or to mixed hydrocarbons. These data appear to be consistent with studies demonstrating depletion in liver GSH levels among rats subjected to restraint stress. Finally, the depletion of GSH that was observed in liver following a single acute exposure was reduced following five daily exposures to clean, filtered air, suggesting the possibility of habituation to restraint in the nose-only exposure chamber. The finding that placement in a nose-only exposure chamber per se yields liver GSH depletion raises the possibility of an interaction between this mode of toxicant exposure and the toxicological effects of certain inhaled test substances.

  4. Contamination of dental unit water and air outlets following use of clean head system and conventional handpieces.

    PubMed

    Toomarian, Lida; Rikhtegaran, Sahand; Sadighi, Mehrnoosh; Savadi Oskoee, Siavash; Alizadeh Oskoee, Parnian

    2007-01-01

    Dental handpiece is a source of contamination because it is in constant touch with the oral cavity. Sterilization does not seem to be sufficient to prevent penetration of microorganisms into air and water lines of the unit, because negative pressure developed by valves (which are placed in water outlets) and post shut-off inertial rotation of handpiece result in water and debris being sucked into air and water outlets of dental unit. The aim of this study was to compare dental unit contamination following use of clean head system handpieces and conventional handpieces. Twenty-two dental units in the Department of Pediatric Dentistry in Shahid Beheshti Faculty of Dentistry were used for the purpose of this study. A 1.5×108 cfu/mm3 concentration of Staphylococcus epidermis (SE) was used to contaminate the air and water outlets of dental units. Ten clean head system handpieces and 10 conventional handpieces were used for 30 seconds in the above-mentioned suspension. Microbial samples were collected from the air and water lines. Culturing and colony counting procedures were carried out. Data was analyzed by t-test; a value of p<0.01 was considered significant. Results demonstrated a significantly lower SE contamination in water outlets following the use of clean head system (p<0.01). A lower tendency of clean head system handpieces to transmit SE compared to conventional system makes them a better choice for infection control.

  5. Pulse cleaning flow models and numerical computation of candle ceramic filters.

    PubMed

    Tian, Gui-shan; Ma, Zhen-ji; Zhang, Xin-yi; Xu, Ting-xiang

    2002-04-01

    Analytical and numerical computed models are developed for reverse pulse cleaning system of candle ceramic filters. A standard turbulent model is demonstrated suitably to the designing computation of reverse pulse cleaning system from the experimental and one-dimensional computational result. The computed results can be used to guide the designing of reverse pulse cleaning system, which is optimum Venturi geometry. From the computed results, the general conclusions and the designing methods are obtained.

  6. Hydraulic and Clean-in-Place Evaluations for a 12.5-cm Annular Centrifugal Contactor at INL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Troy G. Garn; David H. Meikrantz; Nick R. Mann

    2008-09-01

    Hydraulic and Clean-in-Place Evaluations for a 12.5 cm Annular Centrifugal Contactor at the INL Troy G. Garn, Dave H. Meikrantz, Nick R. Mann, Jack D. Law, Terry A. Todd Idaho National Laboratory Commercially available, Annular Centrifugal Contactors (ACC) are currently being evaluated for processing dissolved nuclear fuel solutions to selectively partition integrated elements using solvent extraction technologies. These evaluations include hydraulic and clean-in-place (CIP) testing of a commercially available 12.5 cm unit. Data from these evaluations is used to support design of future nuclear fuel reprocessing facilities. Hydraulic testing provides contactor throughput performance data on two-phase systems for a widemore » range of operating conditions. Hydraulic testing results on a simple two-phase oil and water system followed by a 30 % Tributyl phosphate in N-dodecane / nitric acid pair are reported. Maximum total throughputs for this size contactor ranged from 20 to 32 liters per minute without significant other phase carryover. A relatively new contactor design enhancement providing Clean-in-Place capability for ACCs was also investigated. Spray nozzles installed into the central rotor shaft allow the rotor internals to be cleaned, offline. Testing of the solids capture of a diatomaceous earth/water slurry feed followed by CIP testing was performed. Solids capture efficiencies of >95% were observed for all tests and short cold water cleaning pulses proved successful at removing solids from the rotor.« less

  7. Space storable propulsion components development

    NASA Technical Reports Server (NTRS)

    Hagler, R., Jr.

    1982-01-01

    The current development status of components to control the flow of propellants (liquid fluorine and hydrazine) in a demonstration space storable propulsion system is discussed. The criteria which determined the designs for the pressure regulator, explosive-actuated valves, propellant shutoff valve, latching solenoid-actuated valve and propellant filter are presented. The test philosophy that was followed during component development is outlined. The results from compatibility demonstrations for reusable connectors, flange seals, and CRES/Ti-6Al4V transition tubes and the evaluations of processes for welding (hand-held TIG, automated TIG, and EB), cleaning for fluorine service, and decontamination after fluorine exposure are described.

  8. Improving environmental cleaning in clinical areas: staff education based on adenosine triphosphate readings.

    PubMed

    Villanueva, Ariadna; Guanche, Humberto

    2016-11-01

    Aim To describe the effect of education on environmental cleaning in patient care areas using adenosine triphosphate (ATP) readings. Method A quality improvement initiative was developed in a community hospital in Qatar. Over a two-month period, an infection-control practitioner monitored ATP readings in patient care areas, at any time and regardless of the time of the previous disinfection. The initiative included staff education, use of ATP readings and the drawing up of quarterly quality reports. The ATP readings were considered 'pass', meaning well cleaned, or 'fail', meaning non-cleaned, according to the following standards:>250 relative light units (RLU) in non-critical units and<200RLU for critical units. The proportion of test passes was calculated per 100 tests performed. Results A total of 1,617 tests were performed, after which 1,259 (78%) surfaces were identified as well cleaned. The lowest proportion of non-pass and higher ATP readings was observed in non-critical areas. The test points with the lowest proportion of passes were telephones (40.5%), a medication dispensing system (58.5%), an oximeter (66.7%) and callbox buttons (67.6%). A sustained increase in test passes was observed during the study period. Conclusion There was an improvement in environmental cleaning due to monitoring of ATP on surfaces and staff education.

  9. Orion Crew Module Move

    NASA Image and Video Library

    2017-11-17

    Technicians in clean-room suits attach a crane to the Orion crew module for Exploration Mission-1 for its move to the thermal chamber in the Neil Armstrong Operations and Checkout Building high bay at NASA's Kennedy Space Center in Florida. Orion will be lifted out of a test stand and lowered onto another stand to for the move. The crew module will undergo a thermal cycle test to assess the workmanship of critical hardware and structural locations. The test also demonstrates crew module subsystem operations in a thermally stressing environment to confirm no damage or anomalous hardware conditions as a result of the test. The Orion spacecraft will launch atop NASA's Space Launch System rocket on its first uncrewed integrated flight.

  10. Optimization of the cleaning process on a pilot filtration setup for waste water treatment accompanied by flow visualization

    NASA Astrophysics Data System (ADS)

    Bílek, Petr; Hrůza, Jakub

    2018-06-01

    This paper deals with an optimization of the cleaning process on a liquid flat-sheet filter accompanied by visualization of the inlet side of a filter. The cleaning process has a crucial impact on the hydrodynamic properties of flat-sheet filters. Cleaning methods avoid depositing of particles on the filter surface and forming a filtration cake. Visualization significantly helps to optimize the cleaning methods, because it brings new overall view on the filtration process in time. The optical method, described in the article, enables to see flow behaviour in a thin laser sheet on the inlet side of a tested filter during the cleaning process. Visualization is a strong tool for investigation of the processes on filters in details and it is also possible to determine concentration of particles after an image analysis. The impact of air flow rate, inverse pressure drop and duration on the cleaning mechanism is investigated in the article. Images of the cleaning process are compared to the hydrodynamic data. The tests are carried out on a pilot filtration setup for waste water treatment.

  11. Efficiency and durability of a self-cleaning coating on concrete and stones under both natural and artificial ageing trials

    NASA Astrophysics Data System (ADS)

    Carmona-Quiroga, P. M.; Martínez-Ramírez, S.; Viles, H. A.

    2018-03-01

    This study aimed to test the performance under long-term working conditions of a commercial self-cleaning coating, a water-based TiO2 sol, on three building materials important in recent and older European heritage; Portland limestone, Woodkirk sandstone and concrete. First, the compatibility of the coating (effect on petrophysical properties) with the substrates was demonstrated by examining aesthetic properties and water vapour permeability of the building materials and secondly, the self-cleaning ability of the TiO2 nanoparticles in degrading artificial stain (rhodamine B) under UV light was evaluated. Finally, the durability (lasting performance) of photocatalytic activity was assessed during one year of outdoor exposure trial and 2000 h of accelerated ageing in a chamber with UV radiation and condensation cycles. Results showed that photocatalytic activity was unaltered on concrete, whereas on sandstone, particularly after artificial ageing, it was reduced due to the removal of nanoparticles from the surface. On limestone, a decrease of TiO2 content was observed but photodegradation efficiency (ability to perform as self-cleaner) seemed not to be affected.

  12. Self-cleaning of superhydrophobic surfaces by spontaneously jumping condensate drops

    NASA Astrophysics Data System (ADS)

    Wisdom, Katrina; Watson, Jolanta; Watson, Gregory; Chen, Chuan-Hua

    2012-11-01

    The self-cleaning function of superhydrophobic surfaces is conventionally attributed to the removal of contaminating particles by impacting or rolling water droplets, which implies the action of external forces such as gravity. Here, we demonstrate a new self-cleaning mechanism, whereby condensate drops spontaneously jump upon coalescence on a superhydrophobic surface, and the merged drop self-propels away from the surface along with the contaminants. The jumping-condensate mechanism is shown to autonomously clean superhydrophobic cicada wings, where the contaminating particles cannot be removed by external wind flow. Our findings offer new insights for the development of self-cleaning materials.

  13. Update on the MiniCLEAN dark matter experiment

    DOE PAGES

    Rielage, K.; Akashi-Ronquest, M.; Bodmer, M.; ...

    2015-03-24

    The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A² dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize themore » light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional ³⁹Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.« less

  14. Bio-Contamination Control for Spacesuit Garments - A Preliminary Study

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Korona, Adam; Orndoff, Evelyn; Ott, Mark; Poritz, Darwin

    2010-01-01

    This paper outlines a preliminary study to review, test, and improve upon the current state of spacesuit bio-contamination control. The study includes an evaluation of current and advanced suit materials, ground and on-orbit cleaning methods, and microbial test and analysis methods. The first aspect of this study was to identify potential anti-microbial textiles and cleaning agents, and to review current microbial test methods. The anti-microbial cleaning agent and textile market survey included a review of current commercial-off-the-shelf (COTS) products that could potentially be used as future space flight hardware. This review included replacements for any of the softgood layers that may become contaminated during an extravehicular activity (EVA), including the pressure bladder, liquid cooling garment, and ancillary comfort undergarment. After a series of COTS anti-microbial textiles and clean ing agents were identified, a series of four tests were conducted: (1) a stacked configuration test that was conducted in order to review how bio-contamination would propagate through the various suit layers, (2) a individual materials test that evaluated how well each softgood layer either promoted or repressed growth, (3) a cleaning agent test that evaluated the efficacy on each of the baseline bladders, and (4) an evaluation of various COTS anti-microbial textiles. All antimicrobial COTS materials tested appeared to control bacteria colony forming unit (CFU) growth better than the Thermal Comfort Undergarment (TCU) and ACES Liquid Cooling Garment (LCG)/EMU Liquid Cooling Ventilation Garment (LCVG) materials currently in use. However, a comparison of fungi CFU growth in COTS to current suit materials appeared to vary per material. All cleaning agents tested in this study appeared to inhibit the level of bacteria and fungi growth to acceptable levels for short duration tests. While several trends can be obtained from the current analysis, a series of test improvements are described for future microbial testing.

  15. Physicochemical cleaning and recovery of coal

    NASA Astrophysics Data System (ADS)

    Wheelock, T. D.

    1982-03-01

    The development and demonstration of a method of depressing iron pyrites which is applicable to both the froth flotation and oil agglomeration methods of cleaning and recoverying fine-size coal are described.

  16. Power Hardware-in-the-Loop Testing of a Smart Distribution System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendoza Carrillo, Ismael; Breaden, Craig; Medley, Paige

    This paper presents the results of the third and final phase of the National Renewable Energy Lab (NREL) INTEGRATE demonstration: Smart Distribution. For this demonstration, high penetrations of solar PV and wind energy systems were simulated in a power hardware-in-the-loop set-up using a smart distribution test feeder. Simulated and real DERs were controlled by a real-time control platform, which manages grid constraints under high clean energy deployment levels. The power HIL testing, conducted at NREL's ESIF smart power lab, demonstrated how dynamically managing DER increases the grid's hosting capacity by leveraging active network management's (ANM) safe and reliable control framework.more » Results are presented for how ANM's real-time monitoring, automation, and control can be used to manage multiple DERs and multiple constraints associated with high penetrations of DER on a distribution grid. The project also successfully demonstrated the importance of escalating control actions given how ANM enables operation of grid equipment closer to their actual physical limit in the presence of very high levels of intermittent DER.« less

  17. Surface Analysis of the Laser Cleaned Metal Threads

    NASA Astrophysics Data System (ADS)

    Sokhan, M.; Hartog, F.; McPhail, D.

    The laser cleaning of the tarnished silver threads was carried out using Nd:YAG laser radiation at IR (1064 nm) and visible wavelengths (532 nm). The preliminary tests were made on the piece of silk with the silver embroidery with the clean and tarnished areas. FIBS and SIMS analysis were used for analysing the condition of the surface before and after laser irradiation. It was found that irradiation below 0.4 J/cm-2 and higher than 1.0 J/cm-2 fluences aggravates the process of tarnishing and leads to the yellowing effect. The results of preliminary tests were used for finding the optimum cleaning regime for the laser cleaning of the real museum artefact: "Women Riding Jacket" dated to the beginning of 18th century.

  18. Advanced coal conversion process demonstration. Technical progress report for the period July 1, 1995--September 30, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-05-01

    This report describes the technical progress made on the Advanced Coal Conversion Process (ACCP) Demonstration Project from July 1, 1995 through September 30, 1995. The ACCP Demonstration Project is a US Department of Energy (DOE) Clean Coal Technology Project. This project demonstrates an advanced, thermal, coal upgrading process, coupled with physical cleaning techniques, that is designed to upgrade high-moisture, low-rank coals to a high-quality, low-sulfur fuel, registered as the SynCoal process. The coal is processed through three stages (two heating stages followed by an inert cooling stage) of vibrating fluidized bed reactors that remove chemically bound water, carboxyl groups, andmore » volatile sulfur compounds. After thermal upgrading, the cola is put through a deep-bed stratifier cleaning process to separate the pyrite-rich ash from the coal.« less

  19. Environmental monitoring for the DOE coolside and LIMB demonstration extension projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, T.; Contos, L.; Adams, L.

    1992-03-01

    The purpose of this document is to present environmental monitoring data collected during the US Department of Energy Limestone Injection Multistage Burner (DOE LIMB) Demonstration Project Extension at the Ohio Edison Edgewater Generating Station in Lorain, Ohio. The DOE project is an extension of the US Environmental Protection Agency's (EPA's) original LIMB Demonstration. The program is operated nuclear DOE's Clean Coal Technology Program of emerging clean coal technologies'' under the categories of in boiler control of oxides of sulfur and nitrogen'' as well as post-combustion clean-up.'' The objective of the LIMB program is to demonstrate the sulfur dioxide (SO{sub 2})more » and nitrogen oxide (NO{sub x}) emission reduction capabilities of the LIMB system. The LIMB system is a retrofit technology to be used for existing coal-fired boilers equipped with electrostatic precipitators (ESPs).« less

  20. Environmental monitoring for the DOE coolside and LIMB demonstration extension projects. Final report, May--August 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, T.; Contos, L.; Adams, L.

    1992-03-01

    The purpose of this document is to present environmental monitoring data collected during the US Department of Energy Limestone Injection Multistage Burner (DOE LIMB) Demonstration Project Extension at the Ohio Edison Edgewater Generating Station in Lorain, Ohio. The DOE project is an extension of the US Environmental Protection Agency`s (EPA`s) original LIMB Demonstration. The program is operated nuclear DOE`s Clean Coal Technology Program of ``emerging clean coal technologies`` under the categories of ``in boiler control of oxides of sulfur and nitrogen`` as well as ``post-combustion clean-up.`` The objective of the LIMB program is to demonstrate the sulfur dioxide (SO{sub 2})more » and nitrogen oxide (NO{sub x}) emission reduction capabilities of the LIMB system. The LIMB system is a retrofit technology to be used for existing coal-fired boilers equipped with electrostatic precipitators (ESPs).« less

  1. A numerical study on high-pressure water-spray cleaning for CSP reflectors

    NASA Astrophysics Data System (ADS)

    Anglani, Francesco; Barry, John; Dekkers, Willem

    2016-05-01

    Mirror cleaning for concentrated solar thermal (CST) systems is an important aspect of operation and maintenance (O&M), which affects solar field efficiency. The cleaning process involves soil removal by erosion, resulting from droplet impingement on the surface. Several studies have been conducted on dust accumulation and CSP plant reflectivity restoration, demonstrating that parameters such as nozzle diameter, jet impingement angle, interaxial distance between nozzles, standoff distance, water velocity, nozzle pressure and others factors influence the extent of reflectance restoration. In this paper we aim at identifying optimized cleaning strategies suitable for CST plants, able to restore mirror reflectance by high-pressure water-spray systems through the enhancement of shear stress over reflectors' surface. In order to evaluate the forces generated by water-spray jet impingement during the cleaning process, fluid dynamics simulations have been undertaken with ANSYS CFX software. In this analysis, shear forces represent the "critical phenomena" within the soil removal process. Enhancing shear forces on a particular area of the target surface, varying the angle of impingement in combination with the variation of standoff distances, and managing the interaxial distance of nozzles can increase cleaning efficiency. This procedure intends to improve the cleaning operation for CST mirrors reducing spotted surface and increasing particles removal efficiency. However, turbulence developed by adjacent flows decrease the shear stress generated on the reflectors surface. The presence of turbulence is identified by the formation of "fountain regions" which are mostly responsible of cleaning inefficiency. By numerical analysis using ANSYS CFX, we have modelled a stationary water-spray system with an array of three nozzles in line, with two angles of impingement: θ = 90° and θ = 75°. Several numerical tests have been carried out, varying the interaxial distance of nozzles, standoff distance, jet pressure and jet impingement angle in order to identify effective and efficient cleaning procedures to restore collectors' reflectance, decrease turbulence and improve CST plant efficiency. Results show that the forces generated over the flat target surface are proportional to the inlet pressure and to the water velocity over the surface, and that the shear stresses decrease as the standoff distance increases.

  2. 46 CFR 162.050-23 - Separator: Approval tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... must be tested using the mixture pump on the test rig. (4) The influent water used in each test must be clean fresh water or clean fresh water in solution with sodium chloride. In either case, the relative density of the water must be no greater than 1.015 at 20 °C. (5) Each test must be conducted at an ambient...

  3. 46 CFR 162.050-23 - Separator: Approval tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... must be tested using the mixture pump on the test rig. (4) The influent water used in each test must be clean fresh water or clean fresh water in solution with sodium chloride. In either case, the relative density of the water must be no greater than 1.015 at 20 °C. (5) Each test must be conducted at an ambient...

  4. 46 CFR 162.050-23 - Separator: Approval tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... must be tested using the mixture pump on the test rig. (4) The influent water used in each test must be clean fresh water or clean fresh water in solution with sodium chloride. In either case, the relative density of the water must be no greater than 1.015 at 20 °C. (5) Each test must be conducted at an ambient...

  5. 46 CFR 162.050-23 - Separator: Approval tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... must be tested using the mixture pump on the test rig. (4) The influent water used in each test must be clean fresh water or clean fresh water in solution with sodium chloride. In either case, the relative density of the water must be no greater than 1.015 at 20 °C. (5) Each test must be conducted at an ambient...

  6. Comparative study between chemical and atmospheric pressure plasma jet cleaning on glass substrate

    NASA Astrophysics Data System (ADS)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Fhong, Soon Chin; Sahdan, Mohd Zainizan; Nayan, Nafarizal

    2017-01-01

    The atmospheric pressure plasma jet with low frequency and argon as working gas is presented in this paper to demonstrate its application for glass substrate clean and modification. The glass substrate clean by atmospheric pressure plasma jet is an efficient method to replace other substrate clean method. A comparative analysis is done in this paper between substrate cleaned by chemical and plasma treatment methods. Water contact angle reading is taken for a different method of substrate clean and period of treatment. Under the plasma treatment, the sample shows low surface adhesion due to having the surface property of super hydrophilic surface 7.26°. This comparative analysis is necessary in the industrial application for cost production due to sufficient time and method of substrate clean.

  7. Mechanics of load-drag-unload contact cleaning of gecko-inspired fibrillar adhesives.

    PubMed

    Abusomwan, Uyiosa A; Sitti, Metin

    2014-10-14

    Contact self-cleaning of gecko-inspired synthetic adhesives with mushroom-shaped tips has been demonstrated recently using load-drag-unload cleaning procedures similar to that of the natural animal. However, the underlying mechanics of contact cleaning has yet to be fully understood. In this work, we present a detailed experiment of contact self-cleaning that shows that rolling is the dominant mechanism of cleaning for spherical microparticle contaminants, during the load-drag-unload procedure. We also study the effect of dragging rate and normal load on the particle rolling friction. A model of spherical particle rolling on an elastomer fibrillar adhesive interface is developed and agrees well with the experimental results. This study takes us closer to determining design parameters for achieving self-cleaning fibrillar adhesives.

  8. Alternative Fuels Data Center

    Science.gov Websites

    -dominated economy; demonstrating and fostering innovation in the use of clean energy, including alternative a workforce with cross-cutting skills to support a clean energy economy in the state. For more

  9. Simulated-use validation of a sponge ATP method for determining the adequacy of manual cleaning of endoscope channels.

    PubMed

    Alfa, Michelle J; Olson, Nancy

    2016-05-04

    The objective of this study was to validate the relative light unit (RLU) cut-off of adequate cleaning of flexible colonoscopes for an ATP (adenosine tri-phosphate) test kit that used a sponge channel collection method. This was a simulated-use study. The instrument channel segment of a flexible colonoscope was soiled with ATS (artificial test soil) containing approximately 8 Log10 Enterococcus faecalis and Pseudomonas aeruginosa/mL. Full cleaning, partial cleaning and no cleaning were evaluated for ATP, protein and bacterial residuals. Channel samples were collected using a sponge device to assess residual RLUs. Parallel colonoscopes inoculated and cleaned in the same manner were sampled using the flush method to quantitatively assess protein and bacterial residuals. The protein and viable count benchmarks for adequate cleaning were <6.4 ug/cm(2) and <4 Log10 cfu/cm(2). The negative controls for the instrument channel, over the course of the study remained low with on average 14 RLUs, 0.04 ug/cm(2) protein and 0.025 Log10 cfu/cm(2). Partial cleaning resulted in an average of 6601 RLUs, 3.99 ug/cm(2), 5.25 Log10 cfu/cm(2) E. faecalis and 4.48 Log10 cfu/cm(2) P. aeruginosa. After full cleaning, the average RLU was 29 (range 7-71 RLUs) and the average protein, E. faecalis and P. aeruginosa residuals were 0.23 ug/cm(2), 0.79 and 1.61 Log10 cfu/cm(2), respectively. The validated cut-off for acceptable manual cleaning was set at ≤100 RLUs for the sponge collected channel ATP test kit.

  10. Evaluation of surface roughness of enamel after various bonding and clean-up procedures on enamel bonded with three different bonding agents: An in-vitro study

    PubMed Central

    Goel, Amit; Singh, Atul; Gupta, Tarun

    2017-01-01

    Background The purpose of this study was to analyze and compare the enamel surface roughness before bonding and after debonding, to find correlation between the adhesive remnant index and its effect on enamel surface roughness and to evaluate which clean-up method is most efficient to provide a smoother enamel surface. Material and Methods 135 premolars were divided into 3 groups containing 45 premolars in each group. Group I was bonded by using moisture insensitive primer, Group II by using conventional orthodontic adhesive and Group III by using self-etching primer. Each group was divided into 3 sub-groups on the basis of type of clean-up method applied i,e scaling followed by polishing, tungsten carbide bur and Sof-Lex disc. Enamel surface roughness was measured and compared before bonding and after clean-up. Results Evaluation of pre bonding and post clean-up enamel surface roughness (Ra value) with the t test showed that Post clean-up Ra values were greater than Pre bonding Ra values in all the groups except in teeth bonded with self-etching primer cleaned with Sof-Lex disc. Reliability of ARI score taken at different time interval tested with Kruskal Wallis test suggested that all the readings were reliable. Conclusions No clean-up procedure was able to restore the enamel to its original smoothness. Self-etching primer and Sof-Lex disc clean-up method combination restored the enamel surface roughness (Ra value) closest to its pre-treatment value. Key words:Enamel surface roughness, clean-up method, adhesive remnant index. PMID:28512535

  11. Solvent Replacement for Hydrochlorofluorocarbon-225 for Cleaning Oxygen System Components

    NASA Technical Reports Server (NTRS)

    Mitchell, M. A.; Lowrey, N. M.

    2017-01-01

    This Technical Memorandum is the result of a 2-year project funded by the Defense Logistics Agency-Aviation, Hazardous Minimization and Green Products Branch, to identify and test two candidate solvents to replace hydrochlorofluorocarbon-225 (HCFC-225) for cleaning oxygen systems. The solvents were also compared to a second solvent composed predominantly of perfluorobutyl iodide (PFBI), which had received limited approval by the United States Air Force (USAF) for hand wipe cleaning of components for aviators’ breathing oxygen systems. The tests performed for this study were based on those reported in AFRL-ML-WP-TR-2003-4040, “The Wipe Solvent Program,” the test program used to qualify Ikon® Solvent P for USAF applications.The study was completed in August 2014, prior to the completion of a more extensive study funded by the NASA Rocket Propulsion Test (RPT) program. The results of the RPT project are reported in NASA/TP-2015-18207, “Replacement of Hydrochlorofluorocarbon–225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems.” The test methods used in this study for nonvolatile residue (NVR) background, materials compatibility, and cleaning effectiveness were different than those used for the RPT project; a smaller set of materials and contaminants were tested. The tests for this study were complementary to and provided supplementary information for the down-selection process during the course of the test program reported in NASA/TP-2015-218207.

  12. Test results of heat exchanger cleaning in support of ocean thermal energy conversion

    NASA Astrophysics Data System (ADS)

    Lott, D. F.

    1980-12-01

    This report documents tests conducted at the Naval Coastal Systems Center (NCSC) in support of the Department of Energy's Ocean Thermal Energy Conversion (OTEC) Program. These tests covered the period September 1978 to May 1980 and evaluated flow-driven brushes, recirculating sponge rubber balls, chlorination, and mechanical system/chlorination combinations for in-situ cleaning of two potential heat exchanger materials: titanium and aluminum alloy 5052. Tests were successful when fouling resistance was 0.0003 sq. ft. hr-F/Btu. Results indicated systems and cleaning techniques using brushes, soft sponge balls, and various concentrations of chlorine had some potential for maintaining heat transfer efficiency.

  13. Correlating Cleaning Thoroughness with Effectiveness and Briefly Intervening to Affect Cleaning Outcomes: How Clean Is Cleaned?

    PubMed Central

    Hosford, Eve; Ong, Ana; Richesson, Douglas; Fraser, Susan; Kwak, Yoon; Miller, Sonia; Julius, Michael; McGann, Patrick; Lesho, Emil

    2016-01-01

    Objectives The most efficient approach to monitoring and improving cleaning outcomes remains unresolved. We sought to extend the findings of a previous study by determining whether cleaning thoroughness (dye removal) correlates with cleaning efficacy (absence of molecular or cultivable biomaterial) and whether one brief educational intervention improves cleaning outcomes. Design Before-after trial. Setting Newly built community hospital. Intervention 90 minute training refresher with surface-specific performance results. Methods Dye removal, measured by fluorescence, and biomaterial removal and acquisition, measured with culture and culture-independent PCR-based assays, were clandestinely assessed for eight consecutive months. At this midpoint, results were presented to the cleaning staff (intervention) and assessments continued for another eight consecutive months. Results 1273 surfaces were sampled before and after terminal room cleaning. In the short-term, dye removal increased from 40.3% to 50.0% (not significant). For the entire study period, dye removal also improved but not significantly. After the intervention, the number of rooms testing positive for specific pathogenic species by culturing decreased from 55.6% to 36.6% (not significant), and those testing positive by PCR fell from 80.6% to 53.7% (P = 0.016). For nonspecific biomaterial on surfaces: a) removal of cultivable Gram-negatives (GN) trended toward improvement (P = 0.056); b) removal of any cultivable growth was unchanged but acquisition (detection of biomaterial on post-cleaned surfaces that were contaminant-free before cleaning) worsened (P = 0.017); c) removal of PCR-based detection of bacterial DNA improved (P = 0.046), but acquisition worsened (P = 0.003); d) cleaning thoroughness and efficacy were not correlated. Conclusion At this facility, a minor intervention or minimally more aggressive cleaning may reduce pathogen-specific contamination, but not without unintended consequences. PMID:27196635

  14. Correlating Cleaning Thoroughness with Effectiveness and Briefly Intervening to Affect Cleaning Outcomes: How Clean Is Cleaned?

    PubMed

    Clifford, Robert; Sparks, Michael; Hosford, Eve; Ong, Ana; Richesson, Douglas; Fraser, Susan; Kwak, Yoon; Miller, Sonia; Julius, Michael; McGann, Patrick; Lesho, Emil

    2016-01-01

    The most efficient approach to monitoring and improving cleaning outcomes remains unresolved. We sought to extend the findings of a previous study by determining whether cleaning thoroughness (dye removal) correlates with cleaning efficacy (absence of molecular or cultivable biomaterial) and whether one brief educational intervention improves cleaning outcomes. Before-after trial. Newly built community hospital. 90 minute training refresher with surface-specific performance results. Dye removal, measured by fluorescence, and biomaterial removal and acquisition, measured with culture and culture-independent PCR-based assays, were clandestinely assessed for eight consecutive months. At this midpoint, results were presented to the cleaning staff (intervention) and assessments continued for another eight consecutive months. 1273 surfaces were sampled before and after terminal room cleaning. In the short-term, dye removal increased from 40.3% to 50.0% (not significant). For the entire study period, dye removal also improved but not significantly. After the intervention, the number of rooms testing positive for specific pathogenic species by culturing decreased from 55.6% to 36.6% (not significant), and those testing positive by PCR fell from 80.6% to 53.7% (P = 0.016). For nonspecific biomaterial on surfaces: a) removal of cultivable Gram-negatives (GN) trended toward improvement (P = 0.056); b) removal of any cultivable growth was unchanged but acquisition (detection of biomaterial on post-cleaned surfaces that were contaminant-free before cleaning) worsened (P = 0.017); c) removal of PCR-based detection of bacterial DNA improved (P = 0.046), but acquisition worsened (P = 0.003); d) cleaning thoroughness and efficacy were not correlated. At this facility, a minor intervention or minimally more aggressive cleaning may reduce pathogen-specific contamination, but not without unintended consequences.

  15. Evaluating the Impact of Environmentally Friendly Cleaners on System Readiness

    DTIC Science & Technology

    2001-04-05

    branches of the armed services. USAEC and ATC are currently leading a multi-agency initiative to comprehensively test several cleaning products and...34 Any panel with pitting was given a severity rating of 4. Some cleaning products tested to date have had difficulty meeting the criterion for sandwich...DOD agencies will be able to better preserve readiness, save money and avoid bad decisions by knowing which alternative cleaning products meet its

  16. Experimental system for the control of surgically induced infections

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The results are presented of the development tests performed on the experimental system for the control of surgically induced infections. Tests were performed on the portable clean room to demonstrate assembly, collapsability, portability and storage. Collapsing, relocating and storing within the surgery room can be accomplished in 12 minutes. The storage envelope dimensions are 1.64 m x 4.24 m x 2.62 m high. The disassembly transfer to another room, and reassembly were demonstrated. The laminar air flow velocity profile within the enclosure was measured. In the undisturbed area of the enclosure the air flow met the Federal Standard 209a requirements of 27.45 meters per minute + or - 6.10 meters per minute. Smoke tests with simulated surgery equipment and personnel in the enclosure did not indicate any detrimental air flow patterns. It is concluded that the system as designed will perform the functions required for its intended use.

  17. Self-Cleaning Anticondensing Glass via Supersonic Spraying of Silver Nanowires, Silica, and Polystyrene Nanoparticles.

    PubMed

    Lee, Jong-Gun; An, Seongpil; Kim, Tae-Gun; Kim, Min-Woo; Jo, Hong-Seok; Swihart, Mark T; Yarin, Alexander L; Yoon, Sam S

    2017-10-11

    We have sequentially deposited layers of silver nanowires (AgNWs), silicon dioxide (SiO 2 ) nanoparticles, and polystyrene (PS) nanoparticles on uncoated glass by a rapid low-cost supersonic spraying method to create antifrosting, anticondensation, and self-cleaning glass. The conductive silver nanowire network embedded in the coating allows electrical heating of the glass surface. Supersonic spraying is a single-step coating technique that does not require vacuum. The fabricated multifunctional glass was characterized by X-ray diffraction analysis (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM), ultraviolet-visible spectroscopy, and transmission electron microscopy (TEM). The thermal insulation and antifrosting performance were demonstrated using infrared thermal imaging. The reliability of the electrical heating function was tested through extensive cycling. This transparent multifunctional coating holds great promise for use in various smart window designs.

  18. An improved waste collection system for space flight

    NASA Technical Reports Server (NTRS)

    Thornton, William E.; Lofland, William W., Jr.; Whitmore, Henry

    1986-01-01

    Waste collection systems are a critical part of manned space flight. Systems to date have had a number of deficiencies. A new system, which uses a simple mechanical piston compactor and disposable pads allows a clean area for defecation and maximum efficiency of waste collection and storage. The concept has been extensively tested. Flight demonstration units are being built, tested, and scheduled for flight. A prototype operational unit is under construction. This system offers several advantages over existing or planned systems in the areas of crew interface and operation, cost, size, weight, and maintenance and power consumption.

  19. A study of the durability of beryllium rocket engines. [space shuttle reaction control system

    NASA Technical Reports Server (NTRS)

    Paster, R. D.; French, G. C.

    1974-01-01

    An experimental test program was performed to demonstrate the durability of a beryllium INTEREGEN rocket engine when operating under conditions simulating the space shuttle reaction control system. A vibration simulator was exposed to the equivalent of 100 missions of X, Y, and Z axes random vibration to demonstrate the integrity of the recently developed injector-to-chamber braze joint. An off-limits engine was hot fired under extreme conditions of mixture ratio, chamber pressure, and orifice plugging. A durability engine was exposed to six environmental cycles interspersed with hot-fire tests without intermediate cleaning, service, or maintenance. Results from this program indicate the ability of the beryllium INTEREGEN engine concept to meet the operational requirements of the space shuttle reaction control system.

  20. Market assessment of PFBC ash use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bland, A. E.; Brown, T. H., Western Research Institute

    1998-01-01

    Pressurized fluidized bed combustion (PFBC) of coal is undergoing demonstration in the United States, as well as throughout the world. American Electric Power`s (AEP`s) bubbling PFBC 70 MWe Tidd demonstration program in Ohio and pilot-scale development at Foster Wheeler Energia Oy 10 MWth circulating PFBC at Karhula, Finland, have demonstrated the advantages of PFBC technology. Further technology development in the US is planned with the deployment of the technology at the MacIntosh Clean Coal project in Lakeland, Florida. Development of uses for solid wastes from PFBC coal-fired power systems is being actively pursued as part of the demonstration of PFBCmore » technologies. Ashes collected from Foster Wheeler Energia Oy pilot circulating PFBC tests in Karhula, Finland, operating on (1) low sulfur subbituminous and (2) high sulfur bituminous coal; and ash from the AEP`s high-sulfur bituminous coal-fired bubbling PFBC in Brilliant, Ohio, were evaluated in laboratory and pilot-scale ash use testing at Western Research Institute (WRI).« less

  1. Using information and communications technology in a national population-based survey: the Kenya AIDS Indicator Survey 2012.

    PubMed

    Ojwang', James K; Lee, Veronica C; Waruru, Anthony; Ssempijja, Victor; Ng'ang'a, John G; Wakhutu, Brian E; Kandege, Nicholas O; Koske, Danson K; Kamiru, Samuel M; Omondi, Kenneth O; Kakinyi, Mutua; Kim, Andrea A; Oluoch, Tom

    2014-05-01

    With improvements in technology, electronic data capture (EDC) for large surveys is feasible. EDC offers benefits over traditional paper-based data collection, including more accurate data, greater completeness of data, and decreased data cleaning burden. The second Kenya AIDS Indicator Survey (KAIS 2012) was a population-based survey of persons aged 18 months to 64 years. A software application was designed to capture the interview, specimen collection, and home-based testing and counseling data. The application included: interview translations for local languages; options for single, multiple, and fill-in responses; and automated participant eligibility determination. Data quality checks were programmed to automate skip patterns and prohibit outlier responses. A data sharing architecture was developed to transmit the data in real-time from the field to a central server over a virtual private network. KAIS 2012 was conducted between October 2012 and February 2013. Overall, 68,202 records for the interviews, specimen collection, and home-based testing and counseling were entered into the application. Challenges arose during implementation, including poor connectivity and a systems malfunction that created duplicate records, which prevented timely data transmission to the central server. Data cleaning was minimal given the data quality control measures. KAIS 2012 demonstrated the feasibility of using EDC in a population-based survey. The benefits of EDC were apparent in data quality and minimal time needed for data cleaning. Several important lessons were learned, such as the time and monetary investment required before survey implementation, the importance of continuous application testing, and contingency plans for data transmission due to connectivity challenges.

  2. EVALUATION OF THE ELECTRO-PL AND ELECTROKLEAN DUST COLLECTORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis, R.; Kristal, E.; Silverman, L.

    1958-07-21

    Results are presented from performance tests on the Electro-PL and Electro-Klean air cleaning devices. Both devices were tested for moderate cleaning of low loadings such as those encountered in the atmospheric dust range. (C.H.)

  3. Bedding disposal cabinet for containment of aerosols generated by animal cage cleaning procedures.

    PubMed Central

    Baldwin, C L; Sabel, F L; Henke, C B

    1976-01-01

    Laboratory tests with aerosolized spores and animal room tests with uranine dye indicate the effectiveness of a prototype bedding disposal cabinet in reducing airborne contamination generated by cage cleaning procedures. Images PMID:826219

  4. Cleaning, disinfection and sterilization of surface prion contamination.

    PubMed

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  5. 76 FR 19829 - Clean Alternative Fuel Vehicle and Engine Conversions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ...EPA is streamlining the process by which manufacturers of clean alternative fuel conversion systems may demonstrate compliance with vehicle and engine emissions requirements. Specifically, EPA is revising the regulatory criteria for gaining an exemption from the Clean Air Act prohibition against tampering for the conversion of vehicles and engines to operate on a clean alternative fuel. This final rule creates additional compliance options beyond certification that protect manufacturers of clean alternative fuel conversion systems against a tampering violation, depending on the age of the vehicle or engine to be converted. The new options alleviate some economic and procedural impediments to clean alternative fuel conversions while maintaining environmental safeguards to ensure that acceptable emission levels from converted vehicles are sustained.

  6. [Surface disinfection in nursing homes--what is really happening? Study of control success in three Duisburg nursing homes].

    PubMed

    Martin, U; Sonntag, A-K; Neuhaus, B; Karch, H

    2004-10-01

    The effectiveness of cleaning and disinfection of environmental surfaces was evaluated in three nursing homes using bacteriological monitoring. Samples from inmates (nose, throat and wounds) and surface cleaning equipment were also taken. Cleaning solutions, disinfectants and cleaning clothes were found to be highly contaminated in two of three institutions. Referring to the surfaces in some cases disinfection didn't reduce bacterial colony counts and seeded MRSA as a potential pathogen in one nursing home. Six MRSA-positive inmates and identical strains were registered in the environment. MRSA can be used as a marker organism to demonstrate effectiveness of cleaning. To achieve further improvement bacteriological monitoring can help in focussing special cleaning and disinfection related problems.

  7. Suitability of the isolated chicken eye test for classification of extreme pH detergents and cleaning products.

    PubMed

    Cazelle, Elodie; Eskes, Chantra; Hermann, Martina; Jones, Penny; McNamee, Pauline; Prinsen, Menk; Taylor, Hannah; Wijnands, Marcel V W

    2015-04-01

    A.I.S.E. investigated the suitability of the regulatory adopted ICE in vitro test method (OECD TG 438) with or without histopathology to identify detergent and cleaning formulations having extreme pH that require classification as EU CLP/UN GHS Category 1. To this aim, 18 extreme pH detergent and cleaning formulations were tested covering both alkaline and acidic extreme pHs. The ICE standard test method following OECD Test Guideline 438 showed good concordance with in vivo classification (83%) and good and balanced specificity and sensitivity values (83%) which are in line with the performances of currently adopted in vitro test guidelines, confirming its suitability to identify Category 1 extreme pH detergent and cleaning products. In contrast to previous findings obtained with non-extreme pH formulations, the use of histopathology did not improve the sensitivity of the assay whilst it strongly decreased its specificity for the extreme pH formulations. Furthermore, use of non-testing prediction rules for classification showed poor concordance values (33% for the extreme pH rule and 61% for the EU CLP additivity approach) with high rates of over-prediction (100% for the extreme pH rule and 50% for the additivity approach), indicating that these non-testing prediction rules are not suitable to predict Category 1 hazards of extreme pH detergent and cleaning formulations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Inheritance of mercury tolerance in the aquatic oligochaete Tubifex tubifex.

    PubMed

    Vidal, Dora Elva; Horne, Alex John

    2003-09-01

    Resistance to contaminants is an important yet unmeasured factor in sediment toxicity tests. The rate at which mercury resistance develops and its genetic persistence in the oligochaete worm Tubifex tubifex were studied under laboratory conditions. Worms were raised for four generations under two different sediment treatments, one reference clean sediment, the other contaminated with mercury. Worms raised in mercury-contaminated sediment developed mercury tolerance that persisted even when the worms were raised for three subsequent generations in clean sediment. Mercury tolerance was determined by comparative water-only toxicity tests with mercury as the only stressor. Control worms had a mean lethal concentration (LC50) of 0.18 mg/L(-1). Worms exposed to high levels of mercury in sediment had high mercury tolerance with a mean LC50 of 1.40 mg/L(-1). When mercury-tolerant and control mercury-intolerant worms were crossed, their descendants also demonstrated mercury tolerance during lethal toxicity tests. The LC50 for worm descendants resulting from this cross was 1.39 mg/L(-1). Adaptation to mercury exposures occurred rapidly in this group of worms and appears to be due to both phenotypic and genotypic mechanisms. Development of contaminant resistance and adaptation may be common phenomena in aquatic benthic invertebrates, which should be considered during the design and interpretation of toxicity tests.

  9. Adhesion and removal kinetics of Bacillus cereus biofilms on Ni-PTFE modified stainless steel.

    PubMed

    Huang, Kang; McLandsborough, Lynne A; Goddard, Julie M

    2016-01-01

    Biofilm control remains a challenge to food safety. A well-studied non-fouling coating involves codeposition of polytetrafluoroethylene (PTFE) during electroless plating. This coating has been reported to reduce foulant build-up during pasteurization, but opportunities remain in demonstrating its efficacy in inhibiting biofilm formation. Herein, the initial adhesion, biofilm formation, and removal kinetics of Bacillus cereus on Ni-PTFE-modified stainless steel (SS) are characterized. Coatings lowered the surface energy of SS and reduced biofilm formation by > 2 log CFU cm(-2). Characterization of the kinetics of biofilm removal during cleaning demonstrated improved cleanability on the Ni-PTFE coated steel. There was no evidence of biofilm after cleaning by either solution on the Ni-PTFE coated steel, whereas more than 3 log and 1 log CFU cm(-2) of bacteria remained on the native steel after cleaning with water and an alkaline cleaner, respectively. This work demonstrates the potential application of Ni-PTFE non-fouling coatings on SS to improve food safety by reducing biofilm formation and improving the cleaning efficiency of food processing equipment.

  10. 46 CFR 162.050-23 - Separator: Approval tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... rates of the oil and water that are mixed to form the influent or by use of an oil content meter on the... must be tested using the mixture pump on the test rig. (4) The influent water used in each test must be clean fresh water or clean fresh water in solution with sodium chloride. In either case, the relative...

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buchholz, Stuart A.

    This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined,more » the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.« less

  12. [Effect of manual cleaning and machine cleaning for dental handpiece].

    PubMed

    Zhou, Xiaoli; Huang, Hao; He, Xiaoyan; Chen, Hui; Zhou, Xiaoying

    2013-08-01

    Comparing the dental handpiece' s cleaning effect between manual cleaning and machine cleaning. Eighty same contaminated dental handpieces were randomly divided into experimental group and control group, each group contains 40 pieces. The experimental group was treated by full automatic washing machine, and the control group was cleaned manually. The cleaning method was conducted according to the operations process standard, then ATP bioluminescence was used to test the cleaning results. Average relative light units (RLU) by ATP bioluminescence detection were as follows: Experimental group was 9, control group was 41. The two groups were less than the recommended RLU value provided by the instrument manufacturer (RLU < or = 45). There was significant difference between the two groups (P < 0.05). The cleaning quality of the experimental group was better than that of control group. It is recommended that the central sterile supply department should clean dental handpieces by machine to ensure the cleaning effect and maintain the quality.

  13. Laser Ablation Cleaning of Self-Reacting Friction Stir Weld Seam Surfaces: A Preliminary Evaluation

    NASA Technical Reports Server (NTRS)

    Nunes, A. C., Jr.; Russell, C. K.; Brooke, S. A.; Parry, Q.; Lowrey, N. M.

    2014-01-01

    Anodized aluminum panels were cleaned by three lasers at three separate sites with a view to determining whether more economical laser cleaning might supplant current manual cleaning methods for preparation of surfaces to be welded by the self-reacting friction stir process. Uncleaned panels yielded welds exhibiting residual oxide defect (ROD) and failing at very low stresses along the trace of the weld seam. Manually cleaned panels yielded welds without ROD; these welds failed at nominal stress levels along an angled fracture surface not following the weld seam trace. Laser cleaned panels yielded welds failing at intermediate stress levels. The inadequacy of the laser cleaning processes leaves questions: Was the anodized aluminum test too stringent to represent actual cleaning requirements? Were the wrong laser cleaning techniques/parameters used for the study? Is the laser cleaning mechanism inadequate for effective preweld surface cleaning?

  14. Test Results of Heat Exchanger Cleaning in Support of Ocean Thermal Energy Conversion.

    DTIC Science & Technology

    1980-12-01

    tests evaluated the performance of three in-situ cleaning techniques in two potential heat exchanger materials ...1-6. 41Mann, M. J., 1979, "Possible Cu-Ni-Clad Steel Material and Abrasive Slurry Cleaning System for Plate-Fin-Type OTEC Heat Exchangers ," in...of a Shell-less Folded Aluminum Tube, OTEC Heat Exchanger ," Proceedings of the Sixth OTEC Conference, Washington, DC, June 19-22, 1978, pp 12.8-1

  15. Approach for ochratoxin A fast screening in spices using clean-up tandem immunoassay columns with confirmation by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).

    PubMed

    Goryacheva, I Yu; De Saeger, S; Lobeau, M; Eremin, S A; Barna-Vetró, I; Van Peteghem, C

    2006-09-01

    An approach for ochratoxin A (OTA) fast cost-effective screening based on clean-up tandem immunoassay columns was developed and optimized for OTA detection with a cut-off level of 10 microg kg(-1) in spices. Two procedures were tested and applied for OTA detection. Column with bottom detection immunolayer was optimized for OTA determination in Capsicum ssp. spices. A modified clean-up tandem immunoassay procedure with top detection immunolayer was successfully applied for all tested spices. Its main advantages were decreasing of the number of analysis steps and quantity of antibody and also minimizing of matrix effects. The total duration of the extraction and analysis was about 40 min for six samples. Chilli, red pepper, pili-pili, cayenne, paprika, nutmeg, ginger, white pepper and black pepper samples were analyzed for OTA contamination by the proposed clean-up tandem immunoassay procedures. Clean-up tandem immunoassay results were confirmed by HPLC-MS/MS with immunoaffinity column clean-up. Among 17 tested Capsicum ssp. spices, 6 samples (35%) contained OTA in a concentration exceeding the 10 microg kg(-1) limit discussed by the European Commission. All tested nutmeg (n=8), ginger (n=5), white pepper (n=7) and black pepper (n=6) samples did not contain OTA above this action level.

  16. Used Solvent Testing and Reclamation. Volume 1. Cold-Cleaning Solvents

    DTIC Science & Technology

    1988-12-01

    spectrometer, and specific gravity meter involve buying routine cleaning supplies , and should not exceed $50. Consequently, these methods were...in addition to routine cleaning supplies . The K13V measurement requires periodic supplies of Kauri-butanol solution. TLC analysis requires glass

  17. The GSFC Combined Approach of ODC Stockpiling and Tribological Testing to Mitigate the Risks of ODC Elimination

    NASA Technical Reports Server (NTRS)

    Predmore, Roamer; LeBoeuf, Claudia; Hovanec, Andrew

    1997-01-01

    In response to the elimination of production of several Ozone Depleting Chemicals (ODC's) which have been widely used in successful space flight mechanism cleaning and lubricating procedures, GSFC developed and implemented an overall philosophy of mitigating the risks to flight hardware during the transition phase to ODC-free cleaning procedures. The short term leg of the philosophy was the stockpiling of an appropriate amount of ODC solvents such that all short term GSFC missions will be able to stay with or revert to heritage cleaning and lubricating procedures in the face of life issues. The long-term leg of that philosophy was the initiation of a several tier testing program that will deliver increasing amounts of information over the next few years, starting with accelerated lubricant life tests that compare lubricant life on surfaces cleaned with ODC solvents with lubricant life on surfaces cleaned with ODC-free solvents. While tribological testing, mechanism life testing and space-flight experience will ultimately bring us into the 21st century with environmentally friendly means of cleaning long-life precision mechanism components, many satellites will be launched over the next few years before a number of important tribological questions can be answered. In order to prepare for this challenge, the Materials Engineering Branch in cooperation with the Electromechanical Branch launched an intensive review of all ongoing missions. The failure risk was determined for each long-life lubricated mechanism based on a number of parameters, including 4 comparison of flight solvents used to clean the heritage/life test hardware. Also studied was the ability of the mechanism manufacturers to stockpile ODC's based on state laws and company policies. A stockpiling strategy was constructed based on this information and subsequently implemented. This paper provides an overview of the GSFC ODC elimination risk mitigation philosophy as well as a detailed examination of the development of the ODC stockpiling plan.

  18. Technologies for Humans in Space with Terrestrial Application for Testing in :envihab

    NASA Astrophysics Data System (ADS)

    Belz, Stefan; Henn, Norbert

    Technologies for humans in space and for a sustainable resource management on Earth are faced to similar recycling challenges. The main differences between life support systems (LSS) in human spaceflight and Earth’s environment are the buffer capacities and enormous diversity of material and organisms in Earth. Thus, LSS in space as a small-scale set-up show quickly the problems of artificial cycle management. Such a cycle management becomes more and more important with increase on world’s population and enlargement of (mega-)cities, in order to provide clean air, clean water and no wasting the environment. There is a need of technologies on Earth and for crewed long-term missions in space focusing on efficient and clean electricity generation, as well as on air, water, food, and waste management at lowest power demand. Existing technologies shall be adapted, and new technologies shall be developed for enhancing quality of life on Earth. The poster demonstrates some significant activities in Germany in the field of air revitalization, biomass and food production by microalgae cultivation, biological water regeneration, synergetic use of fuel cells and electrolyzers, respectively hydrogen and oxygen, in life support and energy systems. These technologies make a strong contribution to higher cycle closures, especially combined in an overall system configuration. The facility of :envihab (Environment and Habitat) in Cologne/Germany enables a unique testbed for integrative experiments from component level to system level, in order to demonstrate and investigate compatibilities, required peripherals devices and diagnostic tools.

  19. Clean Heat: A Technical Response to a Policy Innovation

    PubMed Central

    Hernández, Diana

    2017-01-01

    New York City clean heat policies were enacted to improve air quality, especially reducing exposure to black carbon, particulate matter and sulfur that are linked to environmental degradation and various health risks. This policy measure specifically called for the phase out of residual oil and adoption of cleaner burning fuel sources through boiler conversions in commercial and residential properties throughout the city. This paper describes the process of clean heat technology adoption within the innovative clean heat policy context demonstrating its thorough compliance and discussing implications for scalability in other urban settings. PMID:29657663

  20. A moving mesh unstaggered constrained transport scheme for magnetohydrodynamics

    NASA Astrophysics Data System (ADS)

    Mocz, Philip; Pakmor, Rüdiger; Springel, Volker; Vogelsberger, Mark; Marinacci, Federico; Hernquist, Lars

    2016-11-01

    We present a constrained transport (CT) algorithm for solving the 3D ideal magnetohydrodynamic (MHD) equations on a moving mesh, which maintains the divergence-free condition on the magnetic field to machine-precision. Our CT scheme uses an unstructured representation of the magnetic vector potential, making the numerical method simple and computationally efficient. The scheme is implemented in the moving mesh code AREPO. We demonstrate the performance of the approach with simulations of driven MHD turbulence, a magnetized disc galaxy, and a cosmological volume with primordial magnetic field. We compare the outcomes of these experiments to those obtained with a previously implemented Powell divergence-cleaning scheme. While CT and the Powell technique yield similar results in idealized test problems, some differences are seen in situations more representative of astrophysical flows. In the turbulence simulations, the Powell cleaning scheme artificially grows the mean magnetic field, while CT maintains this conserved quantity of ideal MHD. In the disc simulation, CT gives slower magnetic field growth rate and saturates to equipartition between the turbulent kinetic energy and magnetic energy, whereas Powell cleaning produces a dynamically dominant magnetic field. Such difference has been observed in adaptive-mesh refinement codes with CT and smoothed-particle hydrodynamics codes with divergence-cleaning. In the cosmological simulation, both approaches give similar magnetic amplification, but Powell exhibits more cell-level noise. CT methods in general are more accurate than divergence-cleaning techniques, and, when coupled to a moving mesh can exploit the advantages of automatic spatial/temporal adaptivity and reduced advection errors, allowing for improved astrophysical MHD simulations.

  1. Solvent cleaning of pole transformers containing PCB contaminated insulating oil.

    PubMed

    Kanbe, H; Shibuya, M

    2001-01-01

    In 1989, it was discovered that the recycled insulation oil in pole transformers for electric power supply was contaminated with trace amounts of polychlorinated biphenyls (PCBs; maximum 50 mg-PCB/kg-insulation oil). In order to remove the PCBs from transformer components using n-hexane as a solvent, we investigated the relationship between progressive stages of dismantling and cleaning results. The results are summarized as follows: (1) Based on the cleaning test results, we made an estimate of the residual PCB amount on iron and copper components. By dismantling the test pole transformers into the "iron core and coil portion" and cleaning the components, we achieved a residual PCB amount that was below the limit of detection (0.05 mg-PCB/kg-material). To achieve a residual PCB amount below the limit of detection for the transformer paper component, it was necessary to cut the paper into pieces smaller than 5 mm. We were unable to achieve a residual PCB amount below the limit of detection for the wood component. (2) Compared to Japan's stipulated limited concentration standard values for PCBs, the results of the cleaning test show that cleaning iron or copper components with PCBs only on their surface with the solvent n-hexane will satisfy the limited concentration standard values when care is taken to ensure the component surfaces have adequate contact with the cleaning solvent.

  2. In vitro adhesion of Acanthamoeba castellanii to soft contact lenses depends on water content and disinfection procedure.

    PubMed

    Reverey, Julia F; Fromme, Roland; Leippe, Matthias; Selhuber-Unkel, Christine

    2014-08-01

    To compare the potential of different soft contact lenses to be contaminated with Acanthamoeba castellanii as a function of material parameters and cleaning procedures. Different unworn soft hydrogel and silicone hydrogel contact lenses were incubated with human pathogenic A. castellanii. The adhesion of the acanthamoebae was investigated on the contact lenses and put into relation to their material parameters. The efficacy of a recommended contact lens cleaning procedure in reducing A. castellanii adhesion was investigated. We found that material parameters such as elastic modulus, silicone content, ionic properties and swelling do not influence the adhesion of acanthamoebae to soft contact lenses. A material parameter that influenced adhesion significantly was the water content of the lens. With increasing water content, the adhesion of acanthamoebae increased. By following the cleaning instructions of the manufacturer the contamination of the lenses with A. castellanii could be reduced to a minimum, as shown both on contact lenses and in control experiments. With this study we show that for the tested lenses, the adhesion of A. castellanii to contact lenses is independent of the silicone content of the lens, but depends nonlinearly on the water content of the lens. Furthermore, we demonstrate that applying proper lens cleaning procedures minimizes the risk of acanthamoebae adhesion to contact lenses. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. Clean assembly and integration techniques for the Hubble Space Telescope High Fidelity Mechanical Simulator

    NASA Technical Reports Server (NTRS)

    Hughes, David W.; Hedgeland, Randy J.

    1994-01-01

    A mechanical simulator of the Hubble Space Telescope (HST) Aft Shroud was built to perform verification testing of the Servicing Mission Scientific Instruments (SI's) and to provide a facility for astronaut training. All assembly, integration, and test activities occurred under the guidance of a contamination control plan, and all work was reviewed by a contamination engineer prior to implementation. An integrated approach was followed in which materials selection, manufacturing, assembly, subsystem integration, and end product use were considered and controlled to ensure that the use of the High Fidelity Mechanical Simulator (HFMS) as a verification tool would not contaminate mission critical hardware. Surfaces were cleaned throughout manufacturing, assembly, and integration, and reverification was performed following major activities. Direct surface sampling was the preferred method of verification, but access and material constraints led to the use of indirect methods as well. Although surface geometries and coatings often made contamination verification difficult, final contamination sampling and monitoring demonstrated the ability to maintain a class M5.5 environment with surface levels less than 400B inside the HFMS.

  4. Free-Spinning-Tunnel Investigation of a 1/24-Scale Model of the Grumman F9F-6 Airplane TED No. NACA DE 364

    NASA Technical Reports Server (NTRS)

    Klinar, Walter J.; Healy, Frederick M.

    1952-01-01

    An investigation of a 1/24-scale model of the Grumman F9F-6 airplane has been conducted in the Langley 20-foot free-spinning tunnel. The erect and inverted spin and recovery characteristics of the model were determined for the normal flight loading with the model in the clean condition. The effect of loading variations was investigated briefly. Spin-recovery parachute tests were also performed. The results indicate that erect spins obtained on the airplane in the clean condition will be satisfactorily terminated for all loading conditions provided full rudder reversal is accompanied by moving the ailerons and flaperons (lateral controls) to full with the spin (stick right in a right spin). Inverted spins should be satisfactorily terminated by full reversal of the rudder alone. The model tests indicate that an 11.4-foot (laid-out-flat diameter) tail parachute (drag coefficient approximately 0.73) should be effective as an emergency spin-recovery device during demonstration spins of the airplane provided the towline is attached above the horizontal stabilizer.

  5. Tonopah Test Range Air Monitoring: CY2016 Meteorological, Radiological, and Wind Transported Particulate Observations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, Jenny; Nikolich, George; Shadel, Craig

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This operation resulted in radionuclide-contaminated soils at the Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III, and at the TTR Sandia National Laboratories (SNL) Range Operations Control (ROC) center. The primary objective ofmore » the monitoring effort is to determine if wind blowing across the Clean Slate sites is transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites.« less

  6. [Correlation of bacteria in the contaminated drug and the environmental microbes in the clean room for pharmaceutical microbial test investigated by FTIR].

    PubMed

    Pei, Lin; Hu, Chang-qin; Ma, Shi-hong; Dai, Hui; Hang, Tai-jun

    2007-11-01

    The FTIR method was used to investigate the correlation of bacteria in the contaminated drug and the environmental microbes in the clean room for pharmaceutical microbial test. The similarity of bacteria in the contaminated drug and environmental microbes was compared by critical hit value method and cluster analysis method. This constructed the FTIR spectra library of clean room environmental microbe, and determined the criterion to promptly judge if the bacteria isolated from pharmaceuticals were contaminated by environment or not, hence the exactness of "one-off report" of sterile test result can be guaranteed, and can be used for the dynamic monitoring of environmental bacteria of clean room. The method is proven to be simple, accurate and rapid, and can be easily spread to the pharmaceutical microbial control.

  7. Alternate Test Procedures to Perform Clean Water Act Monitoring for Region 9

    EPA Pesticide Factsheets

    When performing Clean Water Act monitoring, parties interested in using a method not approved in 40 CFR Part 136 must apply to use the alternate test procedure (ATP) in the Region in which the discharging facility is located.

  8. 40 CFR Appendix A to Subpart T of... - Test of Solvent Cleaning Procedures

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... solvent cleaning machine? A. When they are clean B. At any time C. When dripping stops D. Either A or C is.... How do you ensure that parts enter and exit the solvent cleaning machine at the speed required in the.... Measure the time it takes the parts to travel a measured distance. ___ 3. Identify the sources of air...

  9. AiResearch QCGAT engine, airplane, and nacelle design features

    NASA Technical Reports Server (NTRS)

    Heldenbrand, R. W.

    1980-01-01

    The quiet, clean, general aviation turbofan engine and nacelle system was designed and tested. The engine utilized the core of the AiResearch model TFE731-3 engine and incorporated several unique noise- and emissions-reduction features. Components that were successfully adapted to this core include the fan, gearbox, combustor, low-pressure turbine, and associated structure. A highly versatile workhorse nacelle incorporating interchangeable acoustic and hardwall duct liners, showed that large-engine attenuation technology could be applied to small propulsion engines. The application of the mixer compound nozzle demonstrated both performance and noise advantages on the engine. Major performance, emissions, and noise goals were demonstrated.

  10. Electrostatic Hazard Considerations for ODC Solvent Replacement Selection Testing

    NASA Technical Reports Server (NTRS)

    Fairbourn, Brad

    1999-01-01

    ODC solvents are used to clean many critical substrates during solid rocket motor production operations. Electrostatic charge generation incidental to these cleaning operations can pose a major safety issue. Therefore, while determining the acceptability of various ODC replacement cleaners, one aspect of the selection criteria included determining the extent of electric charge generation during a typical solvent cleaning operation. A total of six candidate replacement cleaners, sixteen critical substrates, and two types of cleaning swatch materials were studied in simulated cleaning operations. Charge generation and accumulation effects were investigated by measuring the peak voltage and brush discharging effects associated with each cleaning process combination. In some cases, charge generation was found to be very severe. Using the conductivity information for each cleaner, the peak voltage data could in some cases, be qualitatively predicted. Test results indicated that severe charging effects could result in brush discharges that could potentially result in flash fire hazards when occurring in close proximity to flammable vapor/air mixtures. Process controls to effectively mitigate these hazards are discussed.

  11. Dry syngas purification process for coal gas produced in oxy-fuel type integrated gasification combined cycle power generation with carbon dioxide capturing feature.

    PubMed

    Kobayashi, Makoto; Akiho, Hiroyuki

    2017-12-01

    Electricity production from coal fuel with minimizing efficiency penalty for the carbon dioxide abatement will bring us sustainable and compatible energy utilization. One of the promising options is oxy-fuel type Integrated Gasification Combined Cycle (oxy-fuel IGCC) power generation that is estimated to achieve thermal efficiency of 44% at lower heating value (LHV) base and provide compressed carbon dioxide (CO 2 ) with concentration of 93 vol%. The proper operation of the plant is established by introducing dry syngas cleaning processes to control halide and sulfur compounds satisfying tolerate contaminants level of gas turbine. To realize the dry process, the bench scale test facility was planned to demonstrate the first-ever halide and sulfur removal with fixed bed reactor using actual syngas from O 2 -CO 2 blown gasifier for the oxy-fuel IGCC power generation. Design parameter for the test facility was required for the candidate sorbents for halide removal and sulfur removal. Breakthrough test was performed on two kinds of halide sorbents at accelerated condition and on honeycomb desulfurization sorbent at varied space velocity condition. The results for the both sorbents for halide and sulfur exhibited sufficient removal within the satisfactory short depth of sorbent bed, as well as superior bed conversion of the impurity removal reaction. These performance evaluation of the candidate sorbents of halide and sulfur removal provided rational and affordable design parameters for the bench scale test facility to demonstrate the dry syngas cleaning process for oxy-fuel IGCC system as the scaled up step of process development. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Design of a Vision-Based Sensor for Autonomous Pig House Cleaning

    NASA Astrophysics Data System (ADS)

    Braithwaite, Ian; Blanke, Mogens; Zhang, Guo-Qiang; Carstensen, Jens Michael

    2005-12-01

    Current pig house cleaning procedures are hazardous to the health of farm workers, and yet necessary if the spread of disease between batches of animals is to be satisfactorily controlled. Autonomous cleaning using robot technology offers salient benefits. This paper addresses the feasibility of designing a vision-based system to locate dirty areas and subsequently direct a cleaning robot to remove dirt. Novel results include the characterisation of the spectral properties of real surfaces and dirt in a pig house and the design of illumination to obtain discrimination of clean from dirty areas with a low probability of misclassification. A Bayesian discriminator is shown to be efficient in this context and implementation of a prototype tool demonstrates the feasibility of designing a low-cost vision-based sensor for autonomous cleaning.

  13. Demonstration of disinfection procedure for the development of accurate blood glucose meters in accordance with ISO 15197:2013

    PubMed Central

    Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng

    2017-01-01

    Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3–5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future. PMID:28683148

  14. Demonstration of disinfection procedure for the development of accurate blood glucose meters in accordance with ISO 15197:2013.

    PubMed

    Lin, Shu-Ping; Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng

    2017-01-01

    Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.

  15. MIT Clean Energy Prize: Final Technical Report May 12, 2010 - May 11, 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snyder, Chris; Campbell, Georgina; Salony, Jason

    2011-08-09

    The MIT Clean Energy Prize (MIT CEP) is a venture creation and innovation competition to encourage innovation in the energy space, specifically with regard to clean energy. The Competition invited student teams from any US university to submit student-led ventures that demonstrate a high potential of successfully making clean energy more affordable, with a positive impact on the environment. By focusing on student ventures, the MIT CEP aims to educate the next generation of clean energy entrepreneurs. Teams receive valuable mentoring and hard deadlines that complement the cash prize to accelerate development of ventures. The competition is a year-long educationalmore » process that culminates in the selection of five category finalists and a Grand Prize winner and the distribution of cash prizes to each of those teams. Each entry was submitted in one of five clean energy categories: Renewables, Clean Non-Renewables, Energy Efficiency, Transportation, and Deployment.« less

  16. VISION: Illuminating the Pathways to a Clean Energy Economy - JISEA 2016 Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2016-03-01

    This report demonstrates JISEA's successes over the past year and previews our coming work. The 2016 Annual Report highlights JISEA accomplishments in low-carbon electricity system research, international collaboration, clean energy manufacturing analysis, 21st century innovation strategy, and more. As we look to the coming year, JISEA will continue to navigate complex issues, present unique perspectives, and envision a clean energy economy.

  17. ARC-2007-ACD07-0073-126

    NASA Image and Video Library

    2007-08-07

    LCROSS flight hardware in clean room at Ames N-240. EEL personnel fabricating testing components with Jerry Wang of Ames, Engineering Evaluation labLCROSS flight hardware in clean room at Ames N-240. EEL personnel fabricating testing components with Jerry Wang of Ames, Engineering Evaluation lab

  18. [The distribution of microorganisms in household kitchens. II. Evaluation of results and hygienic inferences].

    PubMed

    Borneff, J; Hassinger, R; Wittig, J; Edenharder, R

    1988-03-01

    The very high morbidity rates of Enteritis infectiosa diseases demand improved prophylactic measures. An important indication of the source of these illnesses is the fact that infections in private households are about three times more frequent than in canteens. Indeed, the rise in morbidity is undoubtedly caused by inadequate treatment of raw products, of meal rests and by insufficient heating processes. Furthermore, in household kitchens no efforts are made to interrupt infection chains, and disinfections are considered as superfluous and housewives are content if their kitchens appear to be clean. The aim of our study performed in a normal household kitchen, was to investigate cross-contamination caused by pathogens, introduced into the kitchen from outdoors. A further aim was to establish the main sources of contamination in order to be able to recommend practical disinfection procedures. The main fields of contamination discovered when 55 meals prepared were: a) working surfaces (including boards of wood and plastics) b) kitchen- and cutting-machines. The amount of test organisms (Sarcinae), introduced into the kitchen (unbeknown to the housewives) by experimentally contaminated minced meat was only reduced by common cleaning procedures, in sofar as nearly half of the original contaminations could be demonstrated to be still present. However, when the normal cleanser was replaced by one containing hypochlorite, and with retention of the same working routines, about 90% bacteriologically clean surfaces were determined. In this way it could be demonstrated that infection chains can be interrupted. It is, however, not correct to compare the efficiency of these procedures with the efficiency of disinfection, according to the Federal Infectious Diseases Act (Bundesseuchengesetz). On practical application of these experiences it must be borne in mind that housewives should not be forced to apply medical disinfection procedures: indeed, traditional and practised cleaning methods should be retained, as far as possible. We recommend therefore that manufacturers supply household cleansers with an anti-bacterial additive, after its application in the kitchens working surfaces and machines are bacteriologically clean. Additionally housewives should be appropriately informed about the necessity of these manipulations. We consider minimization of toxicity and a thorough environmental compatibility of formulations to be self-evident.

  19. Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials

    NASA Technical Reports Server (NTRS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  20. Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials

    NASA Astrophysics Data System (ADS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-09-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm × 2.5 cm) were precleaned and inoculated with 5.8 × 103 cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  1. Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials.

    PubMed

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  2. ANALYSIS OF SAMPLES FROM TANK 5F CHEMICAL CLEANING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poirier, M.; Fink, S.

    2011-03-07

    The Savannah River Site (SRS) is preparing Tank 5F for closure. The first step in preparing the tank for closure is mechanical sludge removal. Following mechanical sludge removal, SRS performed chemical cleaning with oxalic acid to remove the sludge heel. Personnel are currently assessing the effectiveness of the chemical cleaning. SRS personnel collected liquid samples during chemical cleaning and submitted them to Savannah River National Laboratory (SRNL) for analysis. Following chemical cleaning, they collected a solid sample (also known as 'process sample') and submitted it to SRNL for analysis. The authors analyzed these samples to assess the effectiveness of themore » chemical cleaning process. The conclusions from this work are: (1) With the exception of iron, the dissolution of sludge components from Tank 5F agreed with results from the actual waste demonstration performed in 2007. The fraction of iron removed from Tank 5F by chemical cleaning was significantly less than the fraction removed in the SRNL demonstrations. The likely cause of this difference is the high pH following the first oxalic acid strike. (2) Most of the sludge mass remaining in the tank is iron and nickel. (3) The remaining sludge contains approximately 26 kg of barium, 37 kg of chromium, and 37 kg of mercury. (4) Most of the radioactivity remaining in the residual material is beta emitters and {sup 90}Sr. (5) The chemical cleaning removed more than {approx} 90% of the uranium isotopes and {sup 137}Cs. (6) The chemical cleaning removed {approx} 70% of the neptunium, {approx} 83% of the {sup 90}Sr, and {approx} 21% of the {sup 60}Co. (7) The chemical cleaning removed less than 10% of the plutonium, americium, and curium isotopes. (8) The chemical cleaning removed more than 90% of the aluminium, calcium, and sodium from the tank. (9) The cleaning operations removed 61% of lithium, 88% of non-radioactive strontium, and 65% of zirconium. The {sup 90}Sr and non-radioactive strontium were measured by different methods, and the differences in the fraction removed are not statistically significant. (10) Chemical cleaning removed 10-50% of the barium, chromium, iron, magnesium, manganese, and silicon. (11) Chemical cleaning removed only {approx}1% of the nickel.« less

  3. A new approach in dry technology for non-degrading optical and EUV mask cleaning

    NASA Astrophysics Data System (ADS)

    Varghese, Ivin; Smith, Ben; Balooch, Mehdi; Bowers, Chuck

    2012-11-01

    The Eco-Snow Systems group of RAVE N.P., Inc. has developed a new cleaning technique to target several of the advanced and next generation mask clean challenges. This new technique, especially when combined with Eco-Snow Systems cryogenic CO2 cleaning technology, provides several advantages over existing methods because it: 1) is solely based on dry technique without requiring additional complementary aggressive wet chemistries that degrade the mask, 2) operates at atmospheric pressure and therefore avoids expensive and complicated equipment associated with vacuum systems, 3) generates ultra-clean reactants eliminating possible byproduct adders, 4) can be applied locally for site specific cleaning without exposing the rest of the mask or can be used to clean the entire mask, 5) removes organic as well as inorganic particulates and film contaminations, and 6) complements current techniques utilized for cleaning of advanced masks such as reduced chemistry wet cleans. In this paper, we shall present examples demonstrating the capability of this new technique for removal of pellicle glue residues and for critical removal of carbon contamination on EUV masks.

  4. IMPROVED EQUIPMENT CLEANING IN COATED AND LAMINATED SUBSTRATE MANUFACTURING FACILITIES (PHASE II)

    EPA Science Inventory

    The report discusses EPA efforts to identify, demonstrate, and publish pollution prevention information and opportunities for equipment cleaning for the coated and laminated substrate manufacturing industry. It summarizes initial data collected and summarized during industry obse...

  5. CleanFleet final report. Volume 2, project design and implementation

    DOT National Transportation Integrated Search

    1995-12-01

    The South Coast Alternative Fuels Demonstration, called CleanFleet, was conducted in the Los Angeles area from April 1992 through September 1994. The project evaluated five alternative motor fuels in commercial fleet service over a two-year period. T...

  6. Laser Paint Stripping

    DTIC Science & Technology

    1991-06-01

    of this laser system to remove paint from metals, including aluminum, and from carbon fiber reinforced composites cleanly and without damage to the...The tests perpendicular to fiber direction in the unidirectional composite were selected as most sensitive indicators of damage. Flexural tests on the... Composite Flexural Strength Tests 10 2.2.11 Composite Compressive Strength Tests 11 2.2.12 Turbine Blade Cleaning 11 2.2.13 Residual Carbon 11 2.2.14

  7. QCSEE UTW engine powered-lift acoustic performance. [Quiet Clean Short-haul Experimental Engine Under The Wing

    NASA Technical Reports Server (NTRS)

    Loeffler, I. J.; Samanich, N. E.; Bloomer, H. E.

    1980-01-01

    Powered-lift acoustic tests of a quiet clean short-haul experimental engine (QCSEE) under-the-wing (UTW) engine are described. Engine and wing configurations are outlined, along with instrumentation and test facilities. The results of these tests are reported. In addition, the UTW engine powered-lift performance is compared with that of the previously tested QCSEE over-the-wing (OTW) engine.

  8. Manual methods are suboptimal compared with automated methods for cleaning of single-use biopsy forceps.

    PubMed

    Alfa, M J; Nemes, R; Olson, N; Mulaire, A

    2006-08-01

    Most reusable biopsy forceps and all of the currently available single-use biopsy forceps do not have a port that allows fluid flow down the inner tubular shaft of the device. Reusable biopsy forceps are widely used and reprocessed in healthcare facilities, and single-use biopsy forceps are reprocessed either in-house (eg, in Canada and Japan) or by third-party reprocessors (eg, in the United States). The objective of this study was to determine the cleaning efficacy of automated narrow-lumen sonic irrigation cleaning, sonication-only cleaning, and manual cleaning for biopsy forceps. A simulated-use study was performed by inoculating the inner channel of single-use biopsy forceps with artificial test soil containing both Enterococcus faecalis and Geobacillus stearothermophilus at concentrations of 10(6) colony-forming units per milliliter. The cleaning methods evaluated were manual cleaning, sonication-only cleaning, and "retroflush" cleaning by an automated narrow-lumen irrigator. Bioburden and organic soil reduction after washing was evaluated. Forceps used in biopsies of patients were also tested to determine the worst-case soiling levels. Only retroflush irrigation cleaning could effectively remove material from within the shaft portion of the biopsy forceps: it achieved an average reduction of more than 95% in levels of protein, hemoglobin, carbohydrate, and endotoxin. However, even this method of cleaning was not totally effective, as only a 2 log10 reduction in bioburden could be achieved, and there were low residual levels of hemoglobin and carbohydrate. The data from this evaluation indicate that manual and sonication-only cleaning methods for biopsy forceps were totally ineffective in removing material from within the biopsy forceps. Even the use of retroflush cleaning was not totally effective. These findings suggest that in-hospital reprocessing of biopsy forceps with currently available equipment and cleaning methods is suboptimal.

  9. Environmental monitoring in a laboratory animal facility.

    PubMed

    Wellstood-Nuesse, S; Shields, R P

    1976-08-01

    A study was made of the microbial environmental status of an animal facility. Cultures were made of animal and surgical room floors; the germicidal effectiveness of the phenolic disinfectant-detergent employed in the facility was tested against standard test organisms as well as against other microorganisms isolated from the facility, and killing power of the disinfectant-detergent was evaluated during various steps of the usual cleaning procedures, ie, mops and mop bucket solutions were tested before, during, and after mopping a room. It was found that colony counts for animal rooms cleaned with a chlorhexidine disinfectant were much lower than those cleaned with a phenolic disinfectant. The phenolic disinfectant killed some organisms after 10 min exposure, but no others. Pseudomonads were the most resistant organisms. Contaminated mops and mop bucket solutions appeared responsible for the high counts on floors cleaned with the phenolic disinfectant. Guidelines for achievable levels of cleanliness were suggested.

  10. Effects of Contamination and Cleaning on Parachute Structural Textile Elements

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2017-01-01

    Throughout their lifecycle, parachute textiles come into contact with various other substances. This contact may occur during manufacturing and repair, storage and transportation, packing, or actual use. While this interaction does not always result in negative repercussions, it may cause a loss in material strength. This paper examines the strength degradation due to several contaminants as well as the effects of cleaning agents on common parachute materials. Materials tested were: Kevlar cord and webbing, Nylon broadcloth and webbing, and Vectran cord; all of these constitute the major structural elements for CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module. Contaminants tested were: sewing machine oil, dried stamping ink, dirt, basting glue, Sergene, and rust. Recommendations for cleaning (or not cleaning) these materials with respect to each of the contaminants are given in this paper, as well as recommendations for future tests.

  11. 76 FR 9610 - Notice of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... pollution control technology; undertake periodic equipment testing; and to submit required reports. The... DEPARTMENT OF JUSTICE Notice of Proposed Consent Decree Under the Clean Air Act Notice is hereby... the Eastern District of California. The Consent Decree in this Clean Air Act enforcement action...

  12. Annual report, spring 2015. Alternative chemical cleaning methods for high level waste tanks-corrosion test results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wyrwas, R. B.

    The testing presented in this report is in support of the investigation of the Alternative Chemical Cleaning program to aid in developing strategies and technologies to chemically clean radioactive High Level Waste tanks prior to tank closure. The data and conclusions presented here were the examination of the corrosion rates of A285 carbon steel and 304L stainless steel when interacted with the chemical cleaning solution composed of 0.18 M nitric acid and 0.5 wt. % oxalic acid. This solution has been proposed as a dissolution solution that would be used to remove the remaining hard heel portion of the sludgemore » in the waste tanks. This solution was combined with the HM and PUREX simulated sludge with dilution ratios that represent the bulk oxalic cleaning process (20:1 ratio, acid solution to simulant) and the cumulative volume associated with multiple acid strikes (50:1 ratio). The testing was conducted over 28 days at 50°C and deployed two methods to invest the corrosion conditions; passive weight loss coupon and an active electrochemical probe were used to collect data on the corrosion rate and material performance. In addition to investigating the chemical cleaning solutions, electrochemical corrosion testing was performed on acidic and basic solutions containing sodium permanganate at room temperature to explore the corrosion impacts if these solutions were to be implemented to retrieve remaining actinides that are currently in the sludge of the tank.« less

  13. Machining and brazing of accelerating RF cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghodke, S.R.; Barnwal, Rajesh; Mondal, Jayant, E-mail: ghodke_barc@yahoo.co.in

    2014-07-01

    BARC has developed 2856 MHz accelerating cavities for 6 MeV, 9 MeV and 10 MeV RF Linac. New vendors are developed for mass production of accelerating cavity for future projects. New vendors are developing for diamond turning machining, cleaning and brazing processes. Fabrication involved material testing, CNC diamond turning of cavity, cavity cleaning and brazing. Before and after brazing resonance frequency (RF) of cavity was checked with vector network analyser (VNA). A power feed test setup is also fabricated to test power feed cavity before brazing. This test setup will be used to find out assembly performance of power feedmore » cavity and its coupler. This paper discusses about nano machining, cleaning and brazing processes of RF cavities. (author)« less

  14. An assessment of alternatives for replacing Freon 113 in bench type electrical circuit board cleaning at Fermi National Accelerator Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Isakson, K.; Vessell, A.L.

    1994-07-01

    Fermilab is presently phasing out all solvents containing Freon-113 (CFC-113) as part of the continuing Waste Minimization Program. These solvents are used primarily in cleaning the flux off of electronic circuit boards after soldering, specifically in bench type work. Title VI of the Clean Air Act mandates a production phase-out for ozone depleting substances, like CFC-113, by the year 2000. Our study addresses this issue by evaluating and choosing alternative non-CFC solvents to replace the CFC-1 13 solvents at Fermilab. Several potential non-CFC cleaning solvents were tested. The evaluation took place in three parts: controlled experimental evaluation, chemical composition evaluation,more » and employee performed evaluation. First, we performed a controlled nine-step procedure with the potential solvents where each was evaluated in categories such as cleaning effectiveness, odor, residue, type of output and drying time. Next, we listed the chemical composition of each solvent. We noted which solvents contained hydrochlorofluorocarbons because they are targeted for phase-out in the future and will be recognized as interim solutions only. Finally, after preliminary testing, five solvents were chosen as the best options. These solvents were sent to be tested by Fermilab employees who use such materials. Their opinions are valuable not only because they are knowledgeable in this field, but also because they will be using the solvents chosen to replace the CFC-113 solvents. The results favored two ``best alternatives``: Safezone Solvent Flux Remover by Miller-Stephenson and E-Series CFC Free Flux-Off 2000 by Chemtech. Another possible solution also pursued is the no-clean solder option. In our study, we were not able to thoroughly investigate the many types of no-clean solders because of time and financial constraints. The testing that was done, however, showed that no-clean solder was a viable alternative in many cases.« less

  15. Effect of Bearing Cleaning on Long Term Bearing Life

    NASA Technical Reports Server (NTRS)

    Jett, Timothy Raymond; Thom, Robert L.

    1998-01-01

    For many years chlorofluorocarbon (CFC ) based solvents, such as Freon and 1,1,1, Trichloroethane (TCA), were used as bearing cleaning solvents for space mechanisms. The 1995 ban on the production of ozone depleting chemicals (ODC) such as CFCs caused a change to new ODC-free cleaners for the precision bearing cleaning. With this change the question arises what effect if any do these new cleaners have on long term bearing life. The purpose of this study was to evaluate this effect. A one year test using 60 small electrical motors (two bearings per motor) was conducted in a high vacuum environment (2.0* 10(exp -6) torr) at a temperature of 90C. Prior to testing the bearings were cleaned with one of four cleaners. These cleaners included two aqueous based cleaners, a CFC based cleaner and supercritical carbon dioxide. Three space compatible greases were tested. After testing the mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace of each bearing was taken to measure post test wear of the bearings. In addition the bearings were visually examined and analyzed using an optical microscope.

  16. Effect of Bearing Cleaning on Long Term Bearing Life

    NASA Technical Reports Server (NTRS)

    Jett, Tim; Thom, R. L.

    1999-01-01

    For many years chlorofluorocarbon (CFC) based solvents, such as CFC-113 and 1,1,1, trichloroethane (TCA), were used as bearing cleaning solvents for space mechanism bearings. The 1995 ban on the production of ozone depleting chemicals (ODC) such as CFCs caused a change requiring the use of ODC-free cleaners for precision bearing cleaning. With this change the question arises; what effect if any do these new cleaners have on long term bearing life? The purpose of this study was to evaluate this effect. A one year test using 60 small electrical motors (two bearings per motor) was conducted in a high vacuum environment (2.0 x 10(exp -6) torr) at a temperature of 90 C. Prior to testing the bearings were cleaned with one of four cleaners. These cleaners included two aqueous based cleaners, a CFC based cleaner and supercritical carbon dioxide. Three space compatible greases were tested. After testing, the mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace of each bearing was taken to measure post test wear of the bearings. In addition, the bearings were visually examined and analyzed using an optical microscope.

  17. Biosorption for the separation of radionuclides from drainage and process waters of the uranium mining industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glombitza, F.; Eckardt, L.; Hummel, A.

    1995-12-31

    Biosorption means the storage of substances at the cell envelope. Different microbial biomasses were tested for the separation of radionuclides from mining waters. Results of a pilot plant demonstrate the ability of these techniques for water cleaning processes. An effluent concentration of lower than 1 mg/l (in most cases 0.1 mg/1) could be realized in a pilot plant by using pure cells of a methylotrophic strain of bacteria as well as using of a fungal mycelia.

  18. Suppression of stimulus artifact contaminating electrically evoked electromyography.

    PubMed

    Liu, Jie; Li, Sheng; Li, Xiaoyan; Klein, Cliff; Rymer, William Z; Zhou, Ping

    2014-01-01

    Electrical stimulation of muscle or nerve is a very useful technique for understanding of muscle activity and its pathological changes for both diagnostic and therapeutic purposes. During electrical stimulation of a muscle, the recorded M wave is often contaminated by a stimulus artifact. The stimulus artifact must be removed for appropriate analysis and interpretation of M waves. The objective of this study was to develop a novel software based method to remove stimulus artifacts contaminating or superimposing with electrically evoked surface electromyography (EMG) or M wave signals. The multiple stage method uses a series of signal processing techniques, including highlighting and detection of stimulus artifacts using Savitzky-Golay filtering, estimation of the artifact contaminated region with Otsu thresholding, and reconstruction of such region using signal interpolation and smoothing. The developed method was tested using M wave signals recorded from biceps brachii muscles by a linear surface electrode array. To evaluate the performance, a series of semi-synthetic signals were constructed from clean M wave and stimulus artifact recordings with different degrees of overlap between them. The effectiveness of the developed method was quantified by a significant increase in correlation coefficient and a significant decrease in root mean square error between the clean M wave and the reconstructed M wave, compared with those between the clean M wave and the originally contaminated signal. The validity of the developed method was also demonstrated when tested on each channel's M wave recording using a linear electrode array. The developed method can suppress stimulus artifacts contaminating M wave recordings.

  19. Adventitious Carbon on Primary Sample Containment Metal Surfaces

    NASA Technical Reports Server (NTRS)

    Calaway, M. J.; Fries, M. D.

    2015-01-01

    Future missions that return astromaterials with trace carbonaceous signatures will require strict protocols for reducing and controlling terrestrial carbon contamination. Adventitious carbon (AC) on primary sample containers and related hardware is an important source of that contamination. AC is a thin film layer or heterogeneously dispersed carbonaceous material that naturally accrues from the environment on the surface of atmospheric exposed metal parts. To test basic cleaning techniques for AC control, metal surfaces commonly used for flight hardware and curating astromaterials at JSC were cleaned using a basic cleaning protocol and characterized for AC residue. Two electropolished stainless steel 316L (SS- 316L) and two Al 6061 (Al-6061) test coupons (2.5 cm diameter by 0.3 cm thick) were subjected to precision cleaning in the JSC Genesis ISO class 4 cleanroom Precision Cleaning Laboratory. Afterwards, the samples were analyzed by X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy.

  20. Applying a Wearable Voice-Activated Computer to Instructional Applications in Clean Room Environments

    NASA Technical Reports Server (NTRS)

    Graves, Corey A.; Lupisella, Mark L.

    2004-01-01

    The use of wearable computing technology in restrictive environments related to space applications offers promise in a number of domains. The clean room environment is one such domain in which hands-free, heads-up, wearable computing is particularly attractive for education and training because of the nature of clean room work We have developed and tested a Wearable Voice-Activated Computing (WEVAC) system based on clean room applications. Results of this initial proof-of-concept work indicate that there is a strong potential for WEVAC to enhance clean room activities.

  1. Simple, green, and clean removal of a poly(methyl methacrylate) film on chemical vapor deposited graphene

    NASA Astrophysics Data System (ADS)

    Park, J.-H.; Jung, W.; Cho, D.; Seo, J.-T.; Moon, Y.; Woo, S. H.; Lee, C.; Park, C.-Y.; Ahn, J. R.

    2013-10-01

    The clean removal of a poly(methyl methacrylate) (PMMA) film on graphene has been an essential part of the process of transferring chemical vapor deposited graphene to a specific substrate, influencing the quality of the transferred graphene. Here we demonstrate that the clean removal of PMMA can be achieved by a single heat-treatment process without the chemical treatment that was adopted in other methods of PMMA removal. The cleanness of the transferred graphene was confirmed by four-point probe measurements, synchrotron radiation x-ray photoemission spectroscopy, optical images, and Raman spectroscopy.

  2. Automated Reflectance Measurement System Designed and Fabricated to Determine the Limits of Atomic Oxygen Treatment of Art Through Contrast Optimization

    NASA Technical Reports Server (NTRS)

    Sechkar, Edward A.; Stueber, Thomas J.; Rutledge, Sharon K.

    2000-01-01

    Atomic oxygen generated in ground-based research facilities has been used to not only test erosion of candidate spacecraft materials but as a noncontact technique for removing organic deposits from the surfaces of artwork. NASA has patented the use of atomic oxygen to remove carbon-based soot contamination from fire-damaged artwork. The process of cleaning soot-damaged paintings with atomic oxygen requires exposures for variable lengths of time, dependent on the condition of a painting. Care must be exercised while cleaning to prevent the removal of pigment. The cleaning process must be stopped as soon as visual inspection or surface reflectance measurements indicate that cleaning is complete. Both techniques rely on optical comparisons of known bright locations against known dark locations on the artwork being cleaned. Difficulties arise with these techniques when either a known bright or dark location cannot be determined readily. Furthermore, dark locations will lighten with excessive exposure to atomic oxygen. Therefore, an automated test instrument to quantitatively characterize cleaning progression was designed and developed at the NASA Glenn Research Center at Lewis Field to determine when atomic oxygen cleaning is complete.

  3. Optimization and analysis of NF3 in situ chamber cleaning plasmas

    NASA Astrophysics Data System (ADS)

    Ji, Bing; Yang, James H.; Badowski, Peter R.; Karwacki, Eugene J.

    2004-04-01

    We report on the optimization and analysis of a dilute NF3 in situ plasma-enhanced chemical vapor deposition chamber cleaning plasma for an Applied Materials P-5000 DxL chamber. Using design of experiments methodology, we identified and optimized operating conditions within the following process space: 10-15 mol % NF3 diluted with helium, 200-400 sccm NF3 flow rate, 2.5-3.5 Torr chamber pressure, and 950 W rf power. Optical emission spectroscopy and Fourier transform infrared spectroscopy were used to endpoint the cleaning processes and to quantify plasma effluent emissions, respectively. The results demonstrate that dilute NF3-based in situ chamber cleaning can be a viable alternative to perfluorocarbon-based in situ cleans with added benefits. The relationship between chamber clean time and fluorine atom density in the plasma is also investigated.

  4. 40 CFR 60.14 - Modification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... physical change, or change in the method of operation, at an existing electric utility steam generating... projects that are awarded funding from the Department of Energy as permanent clean coal technology... installation, operation, cessation, or removal of a temporary clean coal technology demonstration project is...

  5. Using Information and Communications Technology in a National Population-Based Survey: The Kenya AIDS Indicator Survey 2012

    PubMed Central

    Ojwang’, James K.; Lee, Veronica C.; Waruru, Anthony; Ssempijja, Victor; Ng’ang’a, John G.; Wakhutu, Brian E.; Kandege, Nicholas O.; Koske, Danson K.; Kamiru, Samuel M.; Omondi, Kenneth O.; Kakinyi, Mutua; Kim, Andrea A.; Oluoch, Tom

    2016-01-01

    Background With improvements in technology, electronic data capture (EDC) for large surveys is feasible. EDC offers benefits over traditional paper-based data collection, including more accurate data, greater completeness of data, and decreased data cleaning burden. Methods The second Kenya AIDS Indicator Survey (KAIS 2012) was a population-based survey of persons aged 18 months to 64 years. A software application was designed to capture the interview, specimen collection, and home-based testing and counseling data. The application included: interview translations for local languages; options for single, multiple, and fill-in responses; and automated participant eligibility determination. Data quality checks were programmed to automate skip patterns and prohibit outlier responses. A data sharing architecture was developed to transmit the data in realtime from the field to a central server over a virtual private network. Results KAIS 2012 was conducted between October 2012 and February 2013. Overall, 68,202 records for the interviews, specimen collection, and home-based testing and counseling were entered into the application. Challenges arose during implementation, including poor connectivity and a systems malfunction that created duplicate records, which prevented timely data transmission to the central server. Data cleaning was minimal given the data quality control measures. Conclusions KAIS 2012 demonstrated the feasibility of using EDC in a population-based survey. The benefits of EDC were apparent in data quality and minimal time needed for data cleaning. Several important lessons were learned, such as the time and monetary investment required before survey implementation, the importance of continuous application testing, and contingency plans for data transmission due to connectivity challenges. PMID:24732816

  6. Development of a Replacement for Trichloroethylene in the Two-Stage Cleaning Process

    DTIC Science & Technology

    1992-12-01

    Auger-Determined Carbon/Iron Ratios of Set 4 ..................... 15 3 Abstract Isopropyl alcohol, d- limonene , and a synthetic mineral spirits were...found to be as clean as those alcohol, d- limonene , and a synthetic cleaned by the standard two-stage mineral spirits,- were chosen to be process...selected, therefore, was to soil test specimens with Another candidate was d- limonene . It has representative soils, clean them by the been extensively

  7. Power Systems Development Facility Gasification Test Campaing TC18

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Southern Company Services

    2005-08-31

    In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR Transport Gasifier, a hot gas particulate control device (PCD), advanced syngas cleanup systems, and high pressure solids handling systems. This report details Test Campaign TC18 of the PSDF gasification process. Test campaign TC18 began on June 23, 2005, and ended on August 22, 2005, with the gasifiermore » train accumulating 1,342 hours of operation using Powder River Basin (PRB) subbituminous coal. Some of the testing conducted included commissioning of a new recycle syngas compressor for gasifier aeration, evaluation of PCD filter elements and failsafes, testing of gas cleanup technologies, and further evaluation of solids handling equipment. At the conclusion of TC18, the PSDF gasification process had been operated for more than 7,750 hours.« less

  8. Implementation of environmentally compliant cleaning and insulation bonding for MNASA

    NASA Technical Reports Server (NTRS)

    Hutchens, Dale E.; Keen, Jill M.; Smith, Gary M.; Dillard, Terry W.; Deweese, C. Darrell; Lawson, Seth W.

    1995-01-01

    Historically, many subscale and full-scale rocket motors have employed environmentally and physiologically harmful chemicals during the manufacturing process. This program examines the synergy and interdependency between environmentally acceptable materials for solid rocket motor insulation applications, bonding, corrosion inhibiting, painting, priming, and cleaning, and then implements new materials and processes in subscale motors. Tests have been conducted to eliminate or minimize hazardous chemicals used in the manufacture of modified-NASA materials test motor (MNASA) components and identify alternate materials and/or processes following NASA Operational Environmental Team (NOET) priorities. This presentation describes implementation of high pressure water refurbishment cleaning, aqueous precision cleaning using both Brulin 815 GD and Jettacin, and insulation case bonding using ozone depleting chemical (ODC) compliant primers and adhesives.

  9. Evaluation of an enhanced gravity-based fine-coal circuit for high-sulfur coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohanty, M.K.; Samal, A.R.; Palit, A.

    One of the main objectives of this study was to evaluate a fine-coal cleaning circuit using an enhanced gravity separator specifically for a high sulfur coal application. The evaluation not only included testing of individual unit operations used for fine-coal classification, cleaning and dewatering, but also included testing of the complete circuit simultaneously. At a scale of nearly 2 t/h, two alternative circuits were evaluated to clean a minus 0.6-mm coal stream utilizing a 150-mm-diameter classifying cyclone, a linear screen having a projected surface area of 0.5 m{sup 2}, an enhanced gravity separator having a bowl diameter of 250 mmmore » and a screen-bowl centrifuge having a bowl diameter of 500 mm. The cleaning and dewatering components of both circuits were the same; however, one circuit used a classifying cyclone whereas the other used a linear screen as the classification device. An industrial size coal spiral was used to clean the 2- x 0.6-mm coal size fraction for each circuit to estimate the performance of a complete fine-coal circuit cleaning a minus 2-mm particle size coal stream. The 'linear screen + enhanced gravity separator + screen-bowl circuit' provided superior sulfur and ash-cleaning performance to the alternative circuit that used a classifying cyclone in place of the linear screen. Based on these test data, it was estimated that the use of the recommended circuit to treat 50 t/h of minus 2-mm size coal having feed ash and sulfur contents of 33.9% and 3.28%, respectively, may produce nearly 28.3 t/h of clean coal with product ash and sulfur contents of 9.15% and 1.61 %, respectively.« less

  10. Development of clean coal and clean soil technologies using advanced agglomeration techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ignasiak, B.; Ignasiak, T.; Szymocha, K.

    1990-01-01

    Three major topics are discussed in this report: (1) Upgrading of Low Rank Coals by the Agflotherm Process. Test data, procedures, equipment, etc., are described for co-upgrading of subbituminous coals and heavy oil; (2) Upgrading of Bituminous Coals by the Agflotherm Process. Experimental procedures and data, bench and pilot scale equipments, etc., for beneficiating bituminous coals are described; (3) Soil Clean-up and Hydrocarbon Waste Treatment Process. Batch and pilot plant tests are described for soil contaminated by tar refuse from manufactured gas plant sites. (VC)

  11. Evaluation of pressurized water cleaning systems for hardware refurbishment

    NASA Technical Reports Server (NTRS)

    Dillard, Terry W.; Deweese, Charles D.; Hoppe, David T.; Vickers, John H.; Swenson, Gary J.; Hutchens, Dale E.

    1995-01-01

    Historically, refurbishment processes for RSRM motor cases and components have employed environmentally harmful materials. Specifically, vapor degreasing processes consume and emit large amounts of ozone depleting compounds. This program evaluates the use of pressurized water cleaning systems as a replacement for the vapor degreasing process. Tests have been conducted to determine if high pressure water washing, without any form of additive cleaner, is a viable candidate for replacing vapor degreasing processes. This paper discusses the findings thus far of Engineering Test Plan - 1168 (ETP-1168), 'Evaluation of Pressurized Water Cleaning Systems for Hardware Refurbishment.'

  12. The GSFC Combined Approach of ODC Stockpiling and Tribological Testing to Mitigate the Risks of ODC Elimination

    NASA Technical Reports Server (NTRS)

    Predmore, Roamer; Woods, Claudia; Hovanec, Andrew

    1997-01-01

    In response to the elimination of production of several Ozone Depleting Chemicals (ODCs) which have been widely used in successful space flight mechanism cleaning and lubricating procedures, GSFC developed and implemented an overall philosophy of mitigating the risks to flight hardware during the transition phase to ODC-Free cleaning procedures. One leg of that philosophy is the initiation of a several tier testing program which will deliver increasing amounts of information over the next few years, starting with original surface analysis comparisons between ODC and various ODC-Free cleaning technologies. The other leg is the stockpiling of an appropriate amount of ODC solvents such that all short term GSFC missions will be able to stay with or revert to heritage cleaning and lubricating procedures in the face of life issues. While tribological testing, mechanism life testing and space-flight experience will ultimately bring us into the 21st century with environmentally friendly means of cleaning long-life precision mechanism components, many satellites will be launched over the next few years with a number of important tribological questions unanswered. In order to prepare for this challenge, the Materials Engineering Branch in cooperation with the Electromechanical Branch launched an intensive review of all ongoing missions. The failure risk was determined for each long-life mechanism based on a number of parameters, including a comparison of flight solvents used to clean the heritage/life test hardware. Also studied was the ability of the mechanism manufacturers to stockpile ODCs based on state laws and company policies. A stockpiling strategy was constructed based on this information and subsequently implemented. This paper provides an overview of the GSFC ODC elimination risk mitigation philosophy as well as a detailed examination of the development of the ODC stockpiling plan.

  13. Development and Antarctic Testing of a Maneuverable Probe for Clean In-Situ Analysis and Sampling of Subsurface Ice and Subglacial Aquatic Ecosystems

    NASA Astrophysics Data System (ADS)

    Francke, G.; Dachwald, B.; Kowalski, J.; Digel, I.; Tulaczyk, S. M.; Mikucki, J.; Feldmann, M.; Espe, C.; Schöngarth, S.; Hiecker, S.; Blandfort, D.; Schüller, K.; Plescher, E.

    2016-12-01

    There is significant interest in sampling subglacial environments for geochemical and microbiological studies, but those environments are difficult to access. Such environments exist not only on Earth but are also expected beneath the icy crusts of some outer solar system bodies, like the Jovian moon Europa and the Saturnian moon Enceladus. Existing ice drilling technologies make it cumbersome to maintain microbiologically clean access for sample acquisition and environmental stewardship of potentially fragile subglacial aquatic ecosystems. The "IceMole" is a maneuverable subsurface ice probe for clean in-situ analysis and sampling of glacial ice and subglacial materials. The design is based on combining melting and mechanical propulsion, using an ice screw at the tip of the melting head to maintain firm contact between the melting head and the ice. It can change melting direction by differential heating of the melting head and optional side wall heaters. The first two prototypes were successfully tested between 2010 and 2012 on glaciers in Switzerland and Iceland, where they demonstrated downward, horizontal and upward melting, as well as curve driving and dirt layer penetration. Hence, the IceMole allows maneuvers which may be necessary for obstacle avoidance or target selection. Maneuverability, however, necessitates a sophisticated on-board navigation system capable of autonomous operations. Therefore, between 2012 and 2014, a more advanced probe was developed as part of the "Enceladus Explorer" (EnEx) project. The EnEx-IceMole offers systems for relative positioning based on in-ice attitude determination, acoustic positioning, ultrasonic obstacle and target detection, which is all integrated through a high-level sensor fusion. In December 2014, it was used for clean access into a unique subglacial aquatic environment at Blood Falls, Antarctica, where a subglacial brine sample was successfully obtained after about 17 meters of oblique melting. Particular attention was paid to clean protocols for the sampling of subglacial materials for geochemical and microbiological analysis. Much more development has to be done in many areas, however, until the probe can be used for extraterrestrial applications.

  14. 40 CFR 88.205-94 - California Pilot Test Program Credits Program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Program to meet the clean-fuel vehicle sales requirements through the use of credits. Participation in... be generated by any of the following means: (i) Sale of qualifying clean-fuel vehicles earlier than... requirements of paragraph (g) of this section. (ii) Sale of a greater number of qualifying clean-fuel vehicles...

  15. Incorporation of Hands-On Sterile Technique Instruction in an Introductory Pharmacy Practice Experience

    PubMed Central

    Cruthirds, Danielle; Coward, Lori

    2015-01-01

    Objective. To examine sterile technique and basic sterile compounding procedures among third-year pharmacy students. Design. Third year pharmacy students participating in an introductory pharmacy practice experience (IPPE) in 2012 (n=126) and 2013 (n=119) performed a modified low-risk compounded sterile product (CSP) media fill challenge test, then prepared a 5 mg/mL vancomycin solution that was subsequently analyzed for accuracy. Assessment. To identify deficiencies in sterile procedures, students were observed while performing a modified low-risk CSP media fill challenge test. In the first year of conducting the challenge test (2012), 3 deficiencies were identified: hand washing before compounding, cleaning items with alcohol prior to start, and cleaning work area upon completion. In 2013, significant improvements were observed in these 3 areas after students watched a demonstration video. Examination of CSPs revealed less than 1% contamination in both years. Analysis of compounded vancomycin solutions showed that 84% and 71% of students prepared solutions in 2012 and 2013, respectively, were within 10% of the targeted final concentration. Conclusion. Hands-on sterile compounding exercises are typically delivered early in the pharmacy professional curriculum with minimal reinforcement in subsequent years. Providing opportunities for advanced pharmacy students to refresh and practice sterile compounding procedures allows students to refine their skills before entering pharmacy practice. PMID:25861109

  16. Performance Evaluation of Axial Flow AG-1 FC and Prototype FM (High Strength) HEPA Filters - 13123

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giffin, Paxton K.; Parsons, Michael S.; Wilson, John A.

    High efficiency particulate air (HEPA) filters are routinely used in DOE nuclear containment activities. The Nuclear Air Cleaning Handbook (NACH) stipulates that air cleaning devices and equipment used in DOE nuclear applications must meet the American Society of Mechanical Engineers (ASME) Code on Nuclear Air and Gas Treatment (AG-1) standard. This testing activity evaluates two different axial flow HEPA filters, those from AG-1 Sections FC and FM. Section FM is under development and has not yet been added to AG-1 due to a lack of qualification data available for these filters. Section FC filters are axial flow units that utilizemore » a fibrous glass filtering medium. The section FM filters utilize a similar fibrous glass medium, but also have scrim backing. The scrim-backed filters have demonstrated the ability to endure pressure impulses capable of completely destroying FC filters. The testing activities presented herein will examine the total lifetime loading for both FC and FM filters under ambient conditions and at elevated conditions of temperature and relative humidity. Results will include loading curves, penetration curves, and testing condition parameters. These testing activities have been developed through collaborations with representatives from the National Nuclear Security Administration (NNSA), DOE Office of Environmental Management (DOE-EM), New Mexico State University, and Mississippi State University. (authors)« less

  17. 40 CFR 60.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... additions” as defined in IRS Publication 534, as would be done for tax purposes. Clean coal technology... Coal Technology’, up to a total amount of $2,500,000,000 for commercial demonstrations of clean coal technology, or similar projects funded through appropriations for the Environmental Protection Agency...

  18. DEMONSTRATION BULLETIN: THERMAL DESORPTION SYSTEM - CLEAN BERKSHIRES, INC.

    EPA Science Inventory

    A thermal desorption system (TDS) has been developed by Clean Berkshires, Inc. (CBI), Lanesboro, Massachusetts for ex-situ treatment of soils and other media contaminated with organic pollutants. The TDS uses heat as both a physical separation mechanism and as a means to destro...

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rielage, K.; Akashi-Ronquest, M.; Bodmer, M.

    The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A² dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize themore » light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional ³⁹Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.« less

  20. Microbiologic evaluation of microfiber mops for surface disinfection.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-11-01

    Recently, health care facilities have started to use a microfiber mopping technique rather than a conventional, cotton string mop to clean floors. The effectiveness of microfiber mops to reduce microbial levels on floors was investigated. We compared the efficacy of microfiber mops with that of conventional, cotton string mops in 3 test conditions (cotton mop and standard wringer bucket, microfiber mop and standard wringer bucket, microfiber system). Twenty-four rooms were evaluated for each test condition. RODAC plates containing D/E Neutralizing Agar were used to assess "precleaning" and "postcleaning" microbial levels. The microfiber system demonstrated superior microbial removal compared with cotton string mops when used with a detergent cleaner (95% vs 68%, respectively). The use of a disinfectant did not improve the microbial elimination demonstrated by the microfiber system (95% vs 95%, respectively). However, use of disinfectant did significantly improve microbial removal when a cotton string mop was used (95% vs 68%, respectively). The microfiber system demonstrated superior microbial removal compared with cotton string mops when used with a detergent cleaner. The use of a disinfectant did not improve the microbial elimination demonstrated by the microfiber system.

  1. Prepsolv (TM): The optimum alternative to 1,1,1-trichloroethane and methyl ethyl ketone for hand-wipe cleaning of aerospace materials

    NASA Technical Reports Server (NTRS)

    Gallagher, R. Scott; Purvis, John A.; Moran, Wade W.

    1995-01-01

    Engineers at Hercules Aerospace, a rocket motor manufacturer in Utah, have worked closely with chemists at Glidco Organics to study the feasibility of using terpenes for zero-residue wipe cleaning. The result of this work is a technological breakthrough, in which the barrier to ultra-low non-volatile residue formation has been broken. After 2 years of development and testing, SCM Glidco Organics has announced the availability of Glidsafe(registered trademark) Prepsolv(TM): a state-of-the-art ultra-low residue terpene wipe cleaning agent that does not require rinsing. Prepsolv(TM) can successfully be used in simple hand-wipe cleaning processes without fear of leaving surface residues. Industry testing has confirmed that Prepsolv(TM) is not only highly effective, but can even be less expensive to use than traditional cleaning solvents like methyl chloroform. This paper addresses the features and benefits of Prepsolv(TM), and presents performance and material compatibility data that characterizes this unique cleaning agent. Since its commercialization, Hercules Aerospace has chosen Prepsolv(TM) as the optimum cleaning agent to replace ozone-depleting solvents in their weapons factory in Magna, UT. Likewise, Boeing has approved Prepsolv(TM) for cleaning components in the manufacture of commercial aircraft at their facilities in Seattle, WA and Wichita, KS. Additional approvals are forthcoming for this uniquely safe and effective solvent.

  2. Superamphiphobic and Electroactive Nanocomposite toward Self-Cleaning, Antiwear, and Anticorrosion Coatings.

    PubMed

    Yuan, Ruixia; Wu, Shiqi; Yu, Peng; Wang, Baohui; Mu, Liwen; Zhang, Xiguang; Zhu, Yixing; Wang, Bing; Wang, Huaiyuan; Zhu, Jiahua

    2016-05-18

    Multifunctional coatings are in urgent demand in emerging fields. In this work, nanocomposite coatings with extraordinary self-cleaning, antiwear, and anticorrosion properties were prepared on aluminum substrate by a facile spraying technique. Core-shell structured polyaniline/functionalized carbon nanotubes (PANI/fCNTs) composite and nanosized silica were synergistically integrated into ethylene tetrafluoroethylene (ETFE) matrix to construct lotus-leaf-like structures, and 1H,1H,2H,2H- perfluorooctyltriethoxysilane (POTS) was used to decrease the surface energy. The composite coating with 6 wt % PANI/fCNTs possesses superamphiphobic property, with contact angles of 167°, 163°, and 159° toward water, glycerol, and ethylene glycol, respectively. This coating demonstrates stable nonwetting performance over a wide temperature range (<400 °C), as well as outstanding self-cleaning ability to prevent contamination by sludge, concentrated H2SO4, and ethylene glycol. Superamphiphobic surface property could be maintained even after 45 000 times abrasion or bending test for 30 times. The coating displayed strong adhesive ability (grade 1 according to the GB/T9286) on the etched aluminum plate. The superamphiphobic surface could be retained after immersion in 1 mol/L HCl and 3.5 wt % NaCl solutions for 60 and 90 d, respectively. It should be noted that this coating reveals significantly improved anticorrosion performance as compared to the bare ETFE coating and ETFE composite coating without PANI/fCNTs. Such coatings with integrated functionalities offer promising self-cleaning and anticorrosion applications under erosive/abrasive environment.

  3. Evaluation of Nanoparticles Emitted from Printers in a Clean Chamber, a Copy Center and Office Rooms: Health Risks of Indoor Air Quality.

    PubMed

    Shi, Xiaofei; Chen, Rui; Huo, Lingling; Zhao, Lin; Bai, Ru; Long, Dingxin; Pui, David Y H; Rang, Weiqing; Chen, Chunying

    2015-12-01

    Indoor air quality has great impact on the human health. An increasing number of studies have shown that printers could release particulate matters and pose adverse effects on indoor air quality. In this study, a thorough investigation was designed to assess the aerosol printer particle total number concentration (TNC) and size distribution in normal office environment, one copy center, and a clean chamber. Particle analyzers, SMPS, OPS, and CPC3007 were used to monitor the total printing process. In normal office environment, 37 laser printers out of all surveyed 55 printers were classified as high particle emitters. Comparing to laser printers, 5 inkjet printers showed no particle emission. Particle emission level in a copy center increased slightly with TNC elevating to about 2 times of the aerosol background. Simulating test in a clean chamber indicated that printer-emitted particles were dominated by particles in nanoscale (diameter of particle, D(p) < 100 nm). These particles in a sealed clean chamber attenuated so slowly that it still held at high level with the concentration of 1.5 x 10(4) particles/cm3 after printing for 2.5 hours. Our present results demonstrate that printers indeed release particulates which keeping at a high concentration level in the indoor environment. Special care should be taken to this kind of widely applied machines and effective controls of particle emission at printing processes are necessary.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carpenter, Daniel; Westover, Tyler; Howe, Daniel

    Here, we report here on an experimental study to produce refinery-ready fuel blendstocks via catalytic hydrodeoxygenation (upgrading) of pyrolysis oil using several biomass feedstocks and various blends. Blends were tested along with the pure materials to determine the effect of blending on product yields and qualities. Within experimental error, oil yields from fast pyrolysis and upgrading are shown to be linear functions of the blend components. Switchgrass exhibited lower fast pyrolysis and upgrading yields than the woody samples, which included clean pine, oriented strand board (OSB), and a mix of pinon and juniper (PJ). The notable exception was PJ, formore » which the poor upgrading yield of 18% was likely associated with the very high viscosity of the PJ fast pyrolysis oil (947 cp). The highest fast pyrolysis yield (54% dry basis) was obtained from clean pine, while the highest upgrading yield (50%) was obtained from a blend of 80% clean pine and 20% OSB (CP 8OSB 2). For switchgrass, reducing the fast pyrolysis temperature to 450 degrees C resulted in a significant increase to the pyrolysis oil yield and reduced hydrogen consumption during hydrotreating, but did not directly affect the hydrotreating oil yield. The water content of fast pyrolysis oils was also observed to increase linearly with the summed content of potassium and sodium, ranging from 21% for clean pine to 37% for switchgrass. Multiple linear regression models demonstrate that fast pyrolysis is strongly dependent upon the contents lignin and volatile matter as well as the sum of potassium and sodium.« less

  5. Chemical cleaning re-invented: clean, lean and green.

    PubMed

    Hanson, Margaret; Vangeel, Michel

    2014-01-01

    A project undertaken in the Central Cleaning Department of Janssen, a Johnson and Johnson pharmaceutical company, demonstrates how ergonomics, environmental and industrial hygiene risks and quality concerns can be tackled simultaneously. The way equipment was cleaned was re-designed by an in-house cross-functional team to ensure a 'clean, lean and green' process. Initiatives included a new layout of the area, and new work processes and equipment to facilitate cleaning and handling items. This resulted in significant improvements: all ergonomics high risk tasks were reduced to moderate or low risk; hearing protection was no longer required; respirator requirement reduced by 67%; solvent use reduced by 73%; productivity improved, with 55% fewer operator hours required; and quality improved 40-fold. The return on investment was estimated at 3.125 years based on an investment of over €1.5 million (2008 prices). This win-win intervention allowed ergonomics, environmental, industrial hygiene, productivity and quality concerns all to be addressed.

  6. 76 FR 77742 - Guidelines Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-14

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 136 [EPA-HQ-OW-2010-0192; FRL-9504-2] Guidelines Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act; Analysis and Sampling... waste constituent. Similarly, if EPA has established sampling requirements, measurements taken under an...

  7. National Emission Standards for Hazardous Air Pollutants (NESHAP): Halogenated Solvent Cleaning - 1993 Proposed Rule and Test Method & Notice of Public Hearing (58 FR 62566)

    EPA Pesticide Factsheets

    This document is a copy of the Federal Register publication of the November 29, 1993 Proposed Rule and Test Method & Notice of Public Hearing for the National Emission Standards for Hazardous Air Pollutants (NESHAP): Halogenated Solvent Cleaning.

  8. Short-term effect of mechanical plaque control on salivary mutans streptococci in preschool children.

    PubMed

    Liu, Min; Ge, Lihong; Zheng, Shuguo; Yuan, Chao; Zhang, Bo; Xu, Tao

    2014-01-01

    To determine the effect of mechanical tooth cleaning by toothbrush and dental floss on mutans streptococci in the saliva of preschool children. This blinded, randomised controlled clinical trial included 54 3-year-old preschool children with detectable mutans streptococci in saliva. The children were randomly divided into a test and a control group. Dental college students cleaned the teeth of test group participants with toothbrush and dental floss under the indication of a plaque disclosing agent once a day. The control group received no intervention. Dentocult SM Strip mutans (D-SM) strips were used to test the mutans streptococci in saliva. The D-SM test scores declined from 1.82 to 0.95 for the test group after the teeth were cleaned 10 times (P < 0.001) and the scores increased to 1.62 after tooth cleaning ceased for 2 weeks (P > 0.05 compared with baseline). The D-SM level of the control group did not change significantly. Meticulous and continuous plaque control with toothbrush and dental floss can decrease the mutans streptococci level in preschool children. However, the effect ceased as the intervention ceased.

  9. Effectiveness of cleaning-disinfection wipes and sprays against multidrug-resistant outbreak strains.

    PubMed

    Kenters, Nikki; Huijskens, Elisabeth G W; de Wit, Sophie C J; van Rosmalen, Joost; Voss, Andreas

    2017-08-01

    Hospital rooms play an important role in the transmission of several health care-associated pathogens. During the last few years, a number of innovative cleaning-disinfecting products have been brought to market. In this study, commercially available products combining cleaning and disinfection were compared, using 2 different application methods. The aim was to determine which product was most effective in simultaneous cleaning and disinfection of surfaces. Seven cleaning-disinfecting wipes and sprays based on different active ingredients were tested for their efficacy in removal of microbial burden and proteins. Efficacy was tested with known Dutch outbreak strains: vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae OXA-48, or Acinetobacter baumannii. For all bacteria, ready-to-use cleaning-disinfecting products reduced the microbial count with a log 10 reduction >5 with a 5-minute exposure time, with the exception of a spray based on hydrogen peroxide. Omitting the aforementioned hydrogen peroxide spray, there were no significant differences between use of a wipe or spray in bacterial load reduction. Using adenosine triphosphate (ATP) measurements, a significant difference in log 10 relative light units (RLU) reduction between various bacteria (P ≤ .001) was observed. In general, a >5 log 10 reduction of colony forming units (CFU) for tested wipes and sprays was obtained for all tested bacteria strains, with exception of hydrogen peroxide spray and VRE. Although ATP may show a difference between pre- and postcleaning, RLU reduction does not correlate with actual CFU reductions. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Particulate Removal Using a CO2 Composite Spray Cleaning System

    NASA Technical Reports Server (NTRS)

    Chen, Nicole; Lin, Ying; Jackson, David; Chung, Shirley

    2016-01-01

    The Planetary Protection surface cleanliness requirements for potential Mars Sample Return hardware that would come in contact with Martian samples may be stricter than previous missions. The Jet Propulsion Laboratory has developed a new technology that will enable us to remove sub-micron size particles from critical hardware surfaces. A hand-held CO2 composite cleaning system was tested to verify its cleaning capabilities. This convenient, portable device can be used in cleanrooms for cleaning after rework or during spacecraft integration and assembly. It is environmentally safe and easy to use. This cleaning concept has the potential to be further developed into a robotic cleaning device on a Mars Lander to be used to clean sample acquisition or sample handling devices in situ. Contaminants of known sizes and concentrations, such as fluorescent microspheres and spores were deposited on common spacecraft material surfaces. The cleaning efficiency results will be presented and discussed.

  11. Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis

    PubMed Central

    2015-01-01

    PURPOSE To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non-quantitatively. RESULTS All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented. PMID:25932314

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF MOBILE SOURCE EMISSIONS CONTROL DEVICES/CLEAN DIESEL TECHNOLOGIES FUEL BORNE CATALYST WITH CLEANAIR SYSTEM'S DIESEL OXIDATION CATALYST

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of the Fuel-Borne Catalyst with CleanAir System's Diesel Oxidation Catalyst manufactured by Clean Diesel Technologies, Inc. The technology is a fuel-borne catalyst used in ultra low sulfur d...

  13. A Few Easy Steps.

    ERIC Educational Resources Information Center

    Ellis, Tom

    2000-01-01

    Examines tested techniques that can keep a school's carpeting in good condition. Cleaning with hot water extraction, removing spills and spots, handling emergency cleanups, and cleaning soft surface flooring are addressed. (GR)

  14. The Effect of ODC-Free Cleaning Techniques on Bearing Lifetimes in the Parched Elastohydrodynamic Regime

    NASA Technical Reports Server (NTRS)

    Jones, William R., Jr.; Toddy, Thomas J.; Predmore, Roamer; Shogrin, Bradley; Herrera-Fierro Pilar

    1997-01-01

    A parched elastohydrodynamic rig was used to determine relative bearing lifetimes as a function of cleaning procedures in a series of accelerated tests. Two ODC-free cleaning procedures (super critical CO2 and ultraviolet-ozone) were compared to a CFC-113 control. Bearings (52100 steel) were run in the counter rotating mode (equivalent to 4600 rpm) with a full complement (i.e. no retainer) and a single charge of lubricant (Krytox 143 AC). Test conditions included: an air atmosphere, 445N load, approx. 1.0 GPa mean Hertz stress. There was approximately a 50% reduction in life with bearings cleaned with UV/ozone and a 70% reduction in life with SFE CO2 when compared to the Freon control. Possible reasons for these decreases in lifetimes are presented.

  15. The Effect of ODC-Free Cleaning Techniques on Bearing Lifetimes in the Parched Elastohydrodynamic Regime

    NASA Technical Reports Server (NTRS)

    Jones, William R., Jr.; Toddy, Thomas J.; Predmore, Roamer; Shogrin, Bradley; Herrera-Fierro, Pilar

    1996-01-01

    A parched elastohydrodynamic rig was used to determine relative bearing lifetimes as a function of cleaning procedures in a series of accelerated tests. Two ODC-free cleaning procedures (super critical CO2 and ultraviolet-ozone) were compared to a CFC-113 control. Bearings (52100 steel) were run in the counter rotating mode (equivalent to 4600 rpm) with a full complement (i.e. no retainer) and a single charge of lubricant (Krytox 143 AC). Test conditions included: an air atmosphere, 445 N load, approx. 1.0 GPa mean Hertz stress. There was approximately a 50% reduction in life with bearings cleaned with UV/ozone and a 70% reduction in life with SFE CO2 when compared to the Freon control. Possible reasons for these decreases in lifetimes are presented.

  16. Sceening, down selection, and implementation of environmentally compliant cleaning and insulation bonding for MNASA

    NASA Astrophysics Data System (ADS)

    Keen, Jill M.; Hutchens, D. E.; Smith, G. M.; Dillard, T. W.

    1994-06-01

    MNASA, a quarter-scale space shuttle solid rocket motor, has historically been processed using environmentally and physiologically harmful chemicals. This program draws from previous testing done in support of full-scale manufacturing and examines the synergy and interdependency between environmentally acceptable materials for Solid Rocket Motor insulation applications, bonding, corrosion inhibiting, painting, priming and cleaning; and then implements new materials and processes in sub-scale motors. Tests have been conducted to eliminate or minimize hazardous chemicals used in the manufacture of MNASA components and identify alternate materials and/or processes following NASA Operational Environment Team (NOET) priorities. This presentation describes implementation of high pressure water refurbishment cleaning, aqueous precision cleaning using both Brulin 815 GD and Jettacin and insulation case bonding using ODC compliant primers and adhesives.

  17. Effect of cleaning status on accuracy and precision of oxygen flowmeters of various ages.

    PubMed

    Fissekis, Stephanie; Hodgson, David S; Bello, Nora M

    2017-07-01

    To evaluate oxygen flowmeters for accuracy and precision, assess the effects of cleaning and assess conformity to the American Society for Testing Materials (ASTM) standards. Experimental study. The flow of oxygen flowmeters from 31 anesthesia machines aged 1-45 years was measured before and after cleaning using a volumetric flow analyzer set at 0.5, 1.0, 2.0, 3.0, and 4.0 L minute -1 . A general linear mixed models approach was used to assess flow accuracy and precision. Flowmeters 1 year of age delivered accurate mean oxygen flows at all settings regardless of cleaning status. Flowmeters ≥5 years of age underdelivered at flows of 3.0 and 4.0 L minute -1 . Flowmeters ≥12 years underdelivered at flows of 2.0, 3.0 and 4.0 L minute -1 prior to cleaning. There was no evidence of any beneficial effect of cleaning on accuracy of flowmeters 5-12 years of age (p > 0.22), but the accuracy of flowmeters ≥15 years of age was improved by cleaning (p < 0.05). Regardless of age, cleaning increased precision, decreasing flow variability by approximately 17%. Nine of 31 uncleaned flowmeters did not meet ASTM standards. After cleaning, a different set of nine flowmeters did not meet standards, including three that had met standards prior to cleaning. Older flowmeters were more likely to underdeliver oxygen, especially at higher flows. Regardless of age, cleaning decreased flow variability, improving precision. However, flowmeters still may fail to meet ASTM standards, regardless of cleaning status. Cleaning anesthesia machine oxygen flowmeters improved precision for all tested machines and partially corrected inaccuracies in flowmeters ≥15 years old. A notable proportion of flowmeters did not meet ASTM standards. Cleaning did not ensure that they subsequently conformed to ASTM standards. We recommend annual flow output validation to identify whether flowmeters are acceptable for continued clinical use. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  18. The gram-negative sensing receptor PGRP-LC contributes to grooming induction in Drosophila

    PubMed Central

    Neyen, Claudine; Lemaitre, Bruno; Marion-Poll, Frédéric

    2017-01-01

    Behavioral resistance protects insects from microbial infection. However, signals inducing insect hygiene behavior are still relatively unexplored. Our previous study demonstrated that olfactory signals from microbes enhance insect hygiene behavior, and gustatory signals even induce the behavior. In this paper, we postulated a cross-talk between behavioral resistance and innate immunity. To examine this hypothesis, we employed a previously validated behavioral test to examine the function of taste signals in inducing a grooming reflex in decapitated flies. Microbes, which activate different pattern recognition systems upstream of immune pathways, were applied to see if there was any correlation between microbial perception and grooming reflex. To narrow down candidate elicitors, the grooming induction tests were conducted with highly purified bacterial components. Lastly, the role of DAP-type peptidoglycan in grooming induction was confirmed. Our results demonstrate that cleaning behavior can be triggered through recognition of DAP-type PGN by its receptor PGRP-LC. PMID:29121087

  19. Advanced technology for reducing aircraft engine pollution

    NASA Technical Reports Server (NTRS)

    Jones, R. E.

    1973-01-01

    The proposed EPA regulations covering emissions of gas turbine engines will require extensive combustor development. The NASA is working to develop technology to meet these goals through a wide variety of combustor research programs conducted in-house, by contract, and by university grant. In-house efforts using the swirl-can modular combustor have demonstrated sizable reduction in NO emission levels. Testing to reduce idle pollutants has included the modification of duplex fuel nozzles to air-assisted nozzles and an exploration of the potential improvements possible with combustors using fuel staging and variable geometry. The Experimental Clean Combustor Program, a large contracted effort, is devoted to the testing and development of combustor concepts designed to achieve a large reduction in the levels of all emissions. This effort is planned to be conducted in three phases with the final phase to be an engine demonstration of the best reduced emission concepts.

  20. Visualization of flow during cleaning process on a liquid nanofibrous filter

    NASA Astrophysics Data System (ADS)

    Bílek, P.

    2017-10-01

    This paper deals with visualization of flow during cleaning process on a nanofibrous filter. Cleaning of a filter is very important part of the filtration process which extends lifetime of the filter and improve filtration properties. Cleaning is carried out on flat-sheet filters, where particles are deposited on the filter surface and form a filtration cake. The cleaning process dislodges the deposited filtration cake, which is loose from the membrane surface to the retentate flow. The blocked pores in the filter are opened again and hydrodynamic properties are restored. The presented optical method enables to see flow behaviour in a thin laser sheet on the inlet side of a tested filter during the cleaning process. The local concentration of solid particles is possible to estimate and achieve new information about the cleaning process. In the article is described the cleaning process on nanofibrous membranes for waste water treatment. The hydrodynamic data were compared to the images of the cleaning process.

  1. Plasma surface cleaning using microwave plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, C.C.; Haselton, H.H.; Nelson, W.D.

    1993-11-01

    In a microwave electron cyclotron resonance (ECR) plasma source, reactive plasmas of oxygen and its mixture with argon are used for plasma-cleaning experiments. Aluminum test samples (0.95 {times} 1.9 cm) were coated with thin films ({le} 20 {mu}m in thickness) of Shell Vitrea oil and cleaned by using such reactive plasmas. The plasma cleaning was done in various discharge conditions with fixed microwave power, rf power, biased potential, gas pressures (0.5 and 5 mtorr), and operating time up to 35 min. The status of plasma cleaning has been monitored by using mass spectroscopy. Mass loss of the samples after plasmamore » cleaning was measured to estimate cleaning rates. Measured clean rates of low pressure (0.5 mtorr) argon/oxygen plasmas were as high as 2.7 {mu}/min. X-ray photoelectron spectroscopy was used to determine cleanliness of the sample surfaces and confirm the effectiveness of plasma cleaning in achieving atomic levels of surface cleanliness. In this paper, significant results are reported and discussed.« less

  2. Shear stress cleaning for surface departiculation

    NASA Technical Reports Server (NTRS)

    Musselman, R. P.; Yarbrough, T. W.

    1986-01-01

    A cleaning technique widely used by the nuclear utility industry for removal of radioactive surface contamination has proven effective at removing non-hazardous contaminant particles as small as 0.1 micrometer. The process employs a controlled high velocity liquid spray inside a vapor containment enclosure to remove particles from a surface. The viscous drag force generated by the cleaning fluid applies a shear stress greater than the adhesion force that holds small particles to a substrate. Fluid mechanics and field tests indicate general cleaning parameters.

  3. Design and development of automatic sharia compliant wheelchair wheels cleaner

    NASA Astrophysics Data System (ADS)

    Shaari, Muhammad Farid; Rasli, Ibrahim Ismail Mohammad; Jamaludin, M. Z. Z. Wan; Isa, W. A. Mohamad; M., H.; Rashid, A. H. Abdul

    2017-04-01

    Sharia compliant wheelchair wheel cleaner was developed in order to assist the muslim Person with Disabilities (PWD) to pray in the mosque without leaving their wheelchair because of the filthy wheels. Though there are many wheelchair wheel cleaning system in the market, it is very rare to find sharia compliant cleaning system that applies sertu concept which is one of the cleaning and purification technique in Islamic practice. The sertu concept is based on 6:1 ratio that refers to the six times pipe water cleaning and one time soiled water cleaning. The development process consists of design stage, fabrication and system installation stage and followed by testing stage. During the design stage, the proposed prototype underwent design brainstorming, operation programming and structural simulation analysis. Once fabricated, the cleaner prototype underwent was tested. The results showed that the prototype can cater load up to 100kg with 1.31×10-6 mm shaft bending displacement. The water ejection timing varied approximately 3% compared to the program.

  4. Using hyperspectral fluorescence spectra of deli commodities to select wavelengths for surveying deli food contact surfaces

    USDA-ARS?s Scientific Manuscript database

    Problems with assessing the efficacy of cleaning and sanitation procedures in delicatessen departments is a recognized food safety concern. Our laboratory demonstrated that cleaning procedures in produce processing plants can be enhanced using a portable fluorescence imaging device. To explore the f...

  5. Use of a portable fluorescence imaging device to facilitate cleaning of deli slicers

    USDA-ARS?s Scientific Manuscript database

    Cross-contamination is a recognized food safety concern for deli departments, and deli slicers remain a particular concern. Our laboratory previously demonstrated that deli commodity residues can be detected using fluorescence imaging, and that the efficacy of cleaning and sanitation in produce proc...

  6. 78 FR 14457 - Guidelines Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-06

    ... Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act; Analysis and Sampling... for use as an alternative oil and grease method. Some comments were specific to the sampling...-side comparison using the specific procedures (e.g. sampling frequency, number of samples, QA/QC, and...

  7. Effect of cleaning methods after reduced-pressure air abrasion on bonding to zirconia ceramic.

    PubMed

    Attia, Ahmed; Kern, Matthias

    2011-12-01

    To evaluate in vitro the influence of different cleaning methods after low-pressure air abrasion on the bond strength of a phosphate monomer-containing luting resin to zirconia ceramic. A total of 112 zirconia ceramic disks were divided into 7 groups (n = 16). In the test groups, disks were air abraded at low pressure (L) 0.05 MPa using 50-μm alumina particles. Prior to bonding, the disks were ultrasonically (U) cleaned either in isopropanol alcohol (AC), hydrofluoric acid (HF), demineralized water (DW), or tap water (TW), or they were used without ultrasonic cleaning. Disks air abraded at a high (H) pressure of 0.25 MPa and cleaned ultrasonically in isopropanol served as positive control; original (O) milled disks used without air abrasion served as the negative control group. Plexiglas tubes filled with composite resin were bonded with the adhesive luting resin Panavia 21 to the ceramic disks. Prior to testing tensile bond strength (TBS), each main group was further subdivided into 2 subgroups (n=8) which were stored in distilled water either at 37°C for 3 days or for 30 days with 7500 thermal cycles. Statistical analyses were conducted with two- and one-way analyses of variance (ANOVA) and Tukey's HSD test. Initial tensile bond strength (TBS) ranged from 32.6 to 42.8 MPa. After 30 days storage in water with thermocycling, TBS ranged from 21.9 to 36.3 MPa. Storage in water and thermocycling significantly decreased the TBS of test groups which were not air abraded (p = 0.05) or which were air abraded but cleaned in tap water (p = 0.002), but not the TBS of the other groups (p > 0.05). Also, the TBS of air-abraded groups were significantly higher than the TBS of the original milled (p < 0.01). Cleaning procedures did not significantly affect TBS either after 3 days or 30 days storage in water and thermocycling (p > 0.05). Air abrasion at 0.05 MPa and ultrasonic cleaning are important factors for improving bonding to zirconia ceramic.

  8. Proceedings of the 21st DOE/NRC Nuclear Air Cleaning Conference; Sessions 1--8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    First, M.W.

    1991-02-01

    Separate abstracts have been prepared for the papers presented at the meeting on nuclear facility air cleaning technology in the following specific areas of interest: air cleaning technologies for the management and disposal of radioactive wastes; Canadian waste management program; radiological health effects models for nuclear power plant accident consequence analysis; filter testing; US standard codes on nuclear air and gas treatment; European community nuclear codes and standards; chemical processing off-gas cleaning; incineration and vitrification; adsorbents; nuclear codes and standards; mathematical modeling techniques; filter technology; safety; containment system venting; and nuclear air cleaning programs around the world. (MB)

  9. Upper-Stage Flight Experiment

    NASA Technical Reports Server (NTRS)

    Anderson, W. E.; Boxwell, R.; Crockett, D. V.; Ross, R.; Lewis, T.; McNeal, C.; Verdarame, K.

    1999-01-01

    For propulsion applications that require that the propellants are storable for long periods, have a high density impulse, and are environmentally clean and non-toxic, the best choice is a combination of high-concentration hydrogen peroxide (High Test Peroxide, or HTP) and a liquid hydrocarbon (LHC) fuel. The HTP/LHC combination is suitable for low-cost launch vehicles, space taxi and space maneuvering vehicles, and kick stages. Orbital Sciences Corporation is under contract with the NASA Marshall Space Flight Center in cooperation with the Air Force Research Lab to design, develop and demonstrate a new low-cost liquid upper stage based on HTP and JP-8. The Upper Stage Flight Experiment (USFE) focuses on key technologies necessary to demonstrate the operation of an inherently simple propulsion system with an innovative, state-of-the-art structure. Two key low-cost vehicle elements will be demonstrated - a 10,000 lbf thrust engine and an integrated composite tank structure. The suborbital flight test of the USFE is scheduled for 2001. Preceding the flight tests are two major series of ground tests at NASA Stennis Space Center and a subscale tank development program to identify compatible composite materials and to verify their compatibility over long periods of time. The ground tests include a thrust chamber development test series and an integrated stage test. This paper summarizes the results from the first phase of the thrust chamber development tests and the results to date from the tank material compatibility tests. Engine and tank configurations that meet the goals of the program are described.

  10. Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howe, Gary; Albritton, John; Denton, David

    In September 2010, RTI and the DOE/NETL signed a cooperative agreement (DE-FE000489) to design, build, and operate a pre-commercial syngas cleaning system that would capture up to 90% of the CO 2 in the syngas slipstream, and demonstrate the ability to reduce syngas contaminants to meet DOE’s specifications for chemical production application. This pre-commercial syngas cleaning system is operated at Tampa Electric Company’s (TEC) 250-MWe integrated gasification combined cycle (IGCC) plant at Polk Power Station (PPS), located near Tampa, Florida. The syngas cleaning system consists of the following units: Warm Gas Desulfurization Process (WDP) - this unit processes a syngasmore » flow equivalent of 50 MWe of power (50 MWe equivalent corresponds to about 2.0 MM scfh of syngas on dry basis) to produce a desulfurized syngas with a total sulfur (H 2S+COS) concentration ~ 10 ppmv. Water Gas Shift (WGS) Reactor - this unit converts sufficient CO into CO 2 to enable 90% capture of the CO 2 in the syngas slipstream. This reactor uses conventional commercial shift catalyst technologies. Low Temperature Gas Cooling (LTGC) - this unit cools the syngas for the low temperature activated MDEA process and separates any condensed water. Activated MDEA Process (aMDEA) - this unit employs a non-selective separation for the CO 2 and H 2S present in the raw syngas stream. Because of the selective sulfur removal by the upstream WDP unit, the CO 2 capture target of 90% CO 2 can be achieved with the added benefit that total sulfur concentration in the CO 2 product is < 100 ppmv. An additional advantage of the activated MDEA process is that the non-selective sulfur removal from the treated syngas reduces sulfur in the treated gas to very low sub-ppmv concentrations, which are required for chemical production applications. Testing to date of this pre-commercial syngas cleaning system has shown that the technology has great potential to provide clean syngas from coal and petcoke-based gasification at increased efficiency and at significantly lower capital and operating costs than conventional syngas cleanup technologies. However, before the technology can be deemed ready for scale-up to a full commercial-scale demonstration, additional R&D testing is needed at the site to address the following critical technical risks: WDP sorbent stability and performance; Impact of WDP on downstream cleanup and conversion steps; Metallurgy and refractory; Syngas cleanup performance and controllability; Carbon capture performance and additional syngas cleanup The proposed plan to acquire this additional R&D data involves: Operation of the units to achieve an additional 3,000 hours of operation of the system within the performance period, with a target of achieving 1,000 hours of those hours via continuous operation of the entire integrated pre-commercial demonstration system; Rapid turnaround of repairs and/or modifications required as necessary to return any specific unit to operating status with documentation and lessons learned to support technology maturation, and; Proactive performance of maintenance activities during any unplanned outages and if possible while operating.« less

  11. Clean Water Act Analytical Methods

    EPA Pesticide Factsheets

    EPA publishes laboratory analytical methods (test procedures) that are used by industries and municipalities to analyze the chemical, physical and biological components of wastewater and other environmental samples required by the Clean Water Act.

  12. Testing the cleaning effectiveness of new ecological aqueous dispersions applied on old icons

    NASA Astrophysics Data System (ADS)

    Vasilache, Viorica; Sandu, Irina Crina Anca; Pruteanu, Silvea; Caldeira, Ana Teresa; Simionescu, Atena Elena; Sandu, Ion

    2016-03-01

    Adherent deposits are very aggressive towards ancient heritage paintings since they affect the varnish and the painting's layers, sometimes reaching the preparative layers. The biggest problem to the restorer is their removal without affecting the patina, the transparent varnish (well preserved) and fine colour glazes made during painting. Therefore, their removal requires preliminary cleaning tests that allow the optimization of the cleaning system composition that is going to be used. The study was focused on organic natural systems, as colourless supernatants, some of them used during ages, but insufficiently studied. The paper presents an evaluation of the effectiveness of cleaning varnished icons of the nineteenth century, with complex conservation cases using supernatants derived from aqueous dispersions extracted from vegetables and dry indigenous herbal infusions. Best results, after six consecutive cleaning steps, on tempera old icon was obtained for a mixture made of mature white onion juice + extract of Soapwort flowers + corn silk tea + acacia tea. As a best result after just one cleaning step was obtained for a quaternary mixture composed from mature white onion juice + mature carrot juice + corn silk tea + aqueous extract of Soapwort flowers.

  13. Non-aqueous cleaning solvent substitution

    NASA Technical Reports Server (NTRS)

    Meier, Gerald J.

    1994-01-01

    A variety of environmental, safety, and health concerns exist over use of chlorinated and fluorinated cleaning solvents. Sandia National Laboratories, Lawrence Livermore National Laboratories, and the Kansas City Division of AlliedSignal have combined efforts to focus on finding alternative cleaning solvents and processes which are effective, environmentally safe, and compliant with local, state, and federal regulations. An alternative solvent has been identified, qualified, and implemented into production of complex electronic assemblies, where aqueous and semi-aqueous cleaning processes are not allowed. Extensive compatibility studies were performed with components, piece-parts, and materials. Electrical testing and accelerated aging were used to screen for detrimental, long-term effects. A terpene, d-limonene, was selected as the solvent of choice, and it was found to be compatible with the components and materials tested. A brief history of the overall project will be presented, along with representative cleaning efficiency results, compatibility results, and residual solvent data. The electronics industry is constantly searching for proven methods and environmentally-safe materials to use in manufacturing processes. The information in this presentation will provide another option to consider on future projects for applications requiring high levels of quality, reliability, and cleanliness from non-aqueous cleaning processes.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marrocco, M.

    The Ohio Power Company`s Tidd Pressurized Fluidized Bed Combined Cycle (PFBC) program continues to be the only operating PFBC demonstration program in the nation. The 70 MWe Tidd Demonstration Plant is a Round 1 Clean Coal Technology Project constructed to demonstrate the viability of PFBC combined cycle technology. The plant is now in Rs fourth year of operation. The technology has clearly demonstrated Rs ability to achieve sulfur capture of greater than 95%. The calcium to sulfur molar ratios have been demonstrated to exceed original projections. Unit availability has steadily increased and has been demonstrated to be competitive with othermore » technologies. The operating experience of the first forty-four months of testing has moved the PFBC process from a {open_quotes}promising technology{close_quotes} to available, proven option for efficient, environmentally acceptable base load generation. Funding for the $210 million program is provided by Ohio Power Company, The U.S. Department of Energy, The Ohio Coal Development Office, and the PFBC process vendors - Asea Brown Boveri Carbon (ABBC) and Babcock and Wilcox (B&W).« less

  15. Suppression of Stimulus Artifact Contaminating Electrically Evoked Electromyography

    PubMed Central

    Liu, Jie; Li, Sheng; Li, Xiaoyan; Klein, Cliff; Rymer, William Z.; Zhou, Ping

    2013-01-01

    Background Electrical stimulation of muscle or nerve is a very useful technique for understanding of muscle activity and its pathological changes for both diagnostic and therapeutic purposes. During electrical stimulation of a muscle, the recorded M wave is often contaminated by a stimulus artifact. The stimulus artifact must be removed for appropriate analysis and interpretation of M waves. Objectives The objective of this study was to develop a novel software based method to remove stimulus artifacts contaminating or superimposing with electrically evoked surface electromyography (EMG) or M wave signals. Methods The multiple stage method uses a series of signal processing techniques, including highlighting and detection of stimulus artifacts using the Savitzky-Golay filtering, estimation of the artifact contaminated region with the Otsu thresholding, and reconstruction of such region using signal interpolation and smoothing. The developed method was tested using M wave signals recorded from biceps brachii muscles by a linear surface electrode array. To evaluate the performance, a series of semi-synthetic signals were constructed from clean M wave and stimulus artifact recordings with different degrees of overlap between them. Results The effectiveness of the developed method was quantified by a significant increase in correlation coefficient and a significant decrease in root mean square error between the clean M wave and the reconstructed M wave, compared with those between the clean M wave and the originally contaminated signal. The validity of the developed method was also demonstrated when tested on each channel’s M wave recording using the linear electrode array. Conclusions The developed method can suppress stimulus artifacts contaminating M wave recordings. PMID:24419021

  16. Designing and Testing of Self-Cleaning Recirculating Zebrafish Tanks.

    PubMed

    Nema, Shubham; Bhargava, Yogesh

    2016-08-01

    Maintenance of large number of zebrafish in captive conditions is a daunting task. This can be eased by the use of recirculating racks with self-cleaning zebrafish tanks. Commercially available systems are costly, and compatibility of intercompany products has never been investigated. Although various cost-effective designs and methods of construction of custom-made recirculating zebrafish racks are available in literature, the design of self-cleaning zebrafish tanks is still not available. In this study, we report the design and method of construction of the self-cleaning unit, which can be fitted in any zebrafish tank. We validated the design by investigating sediment cleaning process in rectangular and cylindrical tank geometries using time lapse imaging. Our results suggest that for both tank geometries, the tanks fitted with self-cleaning unit provided superior sediment cleaning than the tanks fitted with overflow-drain unit. Although the self-cleaning unit could clean the sediment completely from both geometries over prolonged period, the cleaning of sediments was faster in the cylindrical tank than the rectangular tank. In conclusion, cost and efforts of zebrafish maintenance could be significantly reduced through the installation of our self-cleaning unit in any custom-made zebrafish tank.

  17. Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.; Mitchell, Mark A.

    2016-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon the solvent AsahiKlin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

  18. Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.; Mitchell, Mark A.

    2016-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance chlorofluorocarbon-113 was banned, NASA's propulsion test facilities at Marshall Space Flight Center and Stennis Space Center have relied upon the solvent Asahiklin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

  19. Experimental Investigation of Ice Accretion Effects on a Swept Wing

    NASA Technical Reports Server (NTRS)

    Wong, S. C.; Vargas, M.; Papadakis, M.; Yeong, H. W.; Potapczuk, M.

    2005-01-01

    An experimental investigation was conducted to study the effects of 2-, 5-, 10-, and 22.5-min ice accretions on the aerodynamic performance of a swept finite wing. The ice shapes tested included castings of ice accretions obtained from icing tests at the NASA Glenn Icing Research Tunnel (IRT) and simulated ice shapes obtained with the LEWICE 2.0 ice accretion code. The conditions used for the icing tests were selected to provide five glaze ice shapes with complete and incomplete scallop features and a small rime ice shape. The LEWICE ice shapes were defined for the same conditions as those used in the icing tests. All aerodynamic performance tests were conducted in the 7- x 10-ft Low-Speed Wind Tunnel Facility at Wichita State University. Six component force and moment measurements, aileron hinge moments, and surface pressures were obtained for a Reynolds number of 1.8 million based on mean aerodynamic chord and aileron deflections in the range of -15o to 20o. Tests were performed with the clean wing, six IRT ice shape castings, seven smooth LEWICE ice shapes, and seven rough LEWICE ice shapes. Roughness for the LEWICE ice shapes was simulated with 36-size grit. The experiments conducted showed that the glaze ice castings reduced the maximum lift coefficient of the clean wing by 11.5% to 93.6%, while the 5-min rime ice casting increased maximum lift by 3.4%. Minimum iced wing drag was 133% to 3533% greater with respect to the clean case. The drag of the iced wing near the clean wing stall angle of attack was 17% to 104% higher than that of the clean case. In general, the aileron remained effective in changing the lift of the clean and iced wings for all angles of attack and aileron deflections tested. Aileron hinge moments for the iced wing cases remained within the maximum and minimum limits defined by the clean wing hinge moments. Tests conducted with the LEWICE ice shapes showed that in general the trends in aerodynamic performance degradation of the wing with the simulated ice shapes were similar to those obtained with the IRT ice shape castings. However, in most cases, the ice castings resulted in greater aerodynamic performance losses than those obtained with the LEWICE ice shapes. For the majority of the LEWICE ice shapes, the addition of 36-size grit roughness to the smooth ice shapes increased aerodynamic performance losses.

  20. Depth-resolved analytical model and correction algorithm for photothermal optical coherence tomography

    PubMed Central

    Lapierre-Landry, Maryse; Tucker-Schwartz, Jason M.; Skala, Melissa C.

    2016-01-01

    Photothermal OCT (PT-OCT) is an emerging molecular imaging technique that occupies a spatial imaging regime between microscopy and whole body imaging. PT-OCT would benefit from a theoretical model to optimize imaging parameters and test image processing algorithms. We propose the first analytical PT-OCT model to replicate an experimental A-scan in homogeneous and layered samples. We also propose the PT-CLEAN algorithm to reduce phase-accumulation and shadowing, two artifacts found in PT-OCT images, and demonstrate it on phantoms and in vivo mouse tumors. PMID:27446693

  1. Fouling and long-term durability of an integrated forward osmosis and membrane distillation system.

    PubMed

    Husnain, T; Mi, B; Riffat, R

    2015-01-01

    An integrated forward osmosis (FO) and membrane distillation (MD) system has great potential for sustainable wastewater reuse. However, the fouling and long-term durability of the system remains largely unknown. This study investigates the fouling behaviour and efficiency of cleaning procedures of FO and MD membranes used for treating domestic wastewater. Results showed that a significant decline in flux of both FO and MD membranes were observed during treatment of wastewater with organic foulants. However, shear force generated by the increased cross-flow physically removed the loosely attached foulants from the FO membrane surface and resulted in 86-88% recovery of flux by cleaning with tap water. For the MD membrane, almost no flux recovery was achieved due to adsorption of organic foulants on the hydrophobic membrane surface, thus indicating significant irreversible fouling/wetting, which may not be effectively cleaned even with chemical reagents. Long-term (10 d) tests showed consistent performance of the FO membrane by rejecting the contaminants. However, organic foulants reduced the hydrophobicity of the MD membrane, caused wetting problems and allowed contaminants to pass through. The results demonstrate that combination of the FO and MD processes can effectively reduce irreversible membrane fouling and solve the wetting problem of the MD membrane.

  2. The effect of high concentration potassium permanganate on protein contamination from metallic and synthetic rubber airway equipment.

    PubMed

    Laupu, W; Brimacombe, J

    2007-08-01

    We tested the hypothesis that supplementary cleaning using potassium permanganate 8 mg.l(-1) eliminates protein deposits from the reusable metallic and synthetic rubber airway equipment. Twenty Macintosh laryngoscope blades (surgical steel), 20 pairs of Magill's forceps (surgical steel) and 20 Guedel airways (synthetic rubber) were allocated to two groups for supplementary cleaning. In group A, the device was immersed in potassium permanganate 8 mg.l(-1). In group B (controls), the device was immersed in sterile water. The devices were then immersed in a protein staining solution, rinsed and the severity of staining was scored. In addition, the devices were inspected for tissue and then tested for occult blood. Protein contamination was lower in the potassium permanganate group for all devices (each device: p < 0.0001). There was no staining detected in the permanganate group. In the permanganate group, dried tissue was detected in the teeth of one pair of forceps, which was not detected following supplementary cleaning. Additionally, occult blood was detected on two pairs of forceps and a laryngoscope blade, which was not detected following supplementary cleaning. In the control group, no tissue was detected but one pair of forceps and two laryngoscope blades tested positive for occult blood before and after supplementary cleaning. We conclude that supplementary cleaning using potassium permanganate 8 mg.l(-1) eliminates protein deposits from re-usable metallic and synthetic rubber airway equipment.

  3. Adenosine triphosphate bioluminescence for bacteriologic surveillance and reprocessing strategies for minimizing risk of infection transmission by duodenoscopes.

    PubMed

    Sethi, Saurabh; Huang, Robert J; Barakat, Monique T; Banaei, Niaz; Friedland, Shai; Banerjee, Subhas

    2017-06-01

    Recent outbreaks of duodenoscope-transmitted infections underscore the importance of adequate endoscope reprocessing. Adenosine triphosphate (ATP) bioluminescence testing allows rapid evaluation of endoscopes for bacteriologic/biologic residue. In this prospective study we evaluate the utility of ATP in bacteriologic surveillance and the effects of endoscopy staff education and dual cycles of cleaning and high-level disinfection (HLD) on endoscope reprocessing. ATP bioluminescence was measured after precleaning, manual cleaning, and HLD on rinsates from suction-biopsy channels of all endoscopes and elevator channels of duodenoscopes/linear echoendoscopes after use. ATP bioluminescence was remeasured in duodenoscopes (1) after re-education and competency testing of endoscopy staff and subsequently (2) after 2 cycles of precleaning and manual cleaning and single cycle of HLD or (3) after 2 cycles of precleaning, manual cleaning, and HLD. The ideal ATP bioluminescence benchmark of <200 relative light units (RLUs) after manual cleaning was achieved from suction-biopsy channel rinsates of all endoscopes, but 9 of 10 duodenoscope elevator channel rinsates failed to meet this benchmark. Re-education reduced RLUs in duodenoscope elevator channel rinsates after precleaning (23,218.0 vs 1340.5 RLUs, P < .01) and HLD (177.0 vs 12.0 RLUs, P < .01). After 2 cycles of manual cleaning/HLD, duodenoscope elevator channel RLUs achieved levels similar to sterile water, with corresponding negative cultures. ATP testing offers a rapid, inexpensive alternative for detection of endoscope microbial residue. Re-education of endoscopy staff and 2 cycles of cleaning and HLD decreased elevator channel RLUs to levels similar to sterile water and may therefore minimize the risk of transmission of infections by duodenoscopes. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  4. Interdental cleaning and gingival injury potential of interdental toothbrushes.

    PubMed

    Vogel, Marc; Sener, Beatrice; Roos, M; Attin, Thomas; Schmidlin, Patrick R

    2014-01-01

    The effective cleaning of interdental spaces using toothbrushes is a challenge. The aim of the present in vitro study was to evaluate on the one hand the interdental cleaning efficiency and on the other hand the gingival injury potential of an electric single-headed sonic toothbrush (Water-pik) and two single-tufted manual toothbrushes (Curaprox 1009; Lactona Interdental Brush). Brushes were evaluated using a brushing device. Test dental casts (maxillary sextants) consisting of black teeth coated with white paint were brushed using standardized horizontal movements. Thereafter, black (i.e. cleaned) areas were measured planimetrically. The soft tissue injury potential was evaluated using front segments of porcine mandibles. In the same brushing device, test brushes were moved over the gingiva. Before and after each treatment, the porcine mucosa was stained with a plaque disclosing agent to visualize injured areas, which could then be measured planimetrically as well. These evaluations were each made after 15, 30, 60, and 120 seconds of brushing. The statistical analysis was performed using non-parametric Mann-Whitney tests, and the level of significance was set at 5%. The best cleaning performance of 46% across all interdental spaces assessed was found with the electric sonic toothbrush (Waterpik), while the performances of the manual brushes from Lactona and Curaprox were 14.8% and 5%, respectively. At each point of evaluation, the gingiva was injured most markedly by the powered sonic toothbrush (Waterpik), followed by the manual Curaprox brush. The smallest damage of the porcine gingiva was produced by the manual Lactona brush. When comparing the manual toothbrushes, the Lactona product revealed a better cleaning performance combined with a smaller injury potential than the Curaprox brush. Thus, the prophylactic goal to achieve high degrees of cleaning while producing minimal damage is important and should have priority when evaluating and selecting toothbrushes.

  5. Kinematic and kinetic improvements associated with action observation facilitated learning of the power clean in Australian footballers.

    PubMed

    Sakadjian, Alex; Panchuk, Derek; Pearce, Alan J

    2014-06-01

    This study investigated the effectiveness of action observation (AO) on facilitating learning of the power clean technique (kinematics) compared with traditional strength coaching methods and whether improvements in performance (kinetics) were associated with an improvement in lifting technique. Fifteen subjects (age, 20.9 ± 2.3 years) with no experience in performing the power clean exercise attended 12 training and testing sessions over a 4-week period. Subjects were assigned to 2 matched groups, based on preintervention power clean performance and performed 3 sets of 5 repetitions of the power clean exercise at each training session. Subjects in the traditional coaching group (TC; n = 7) received the standard coaching feedback (verbal cues and physical practice), whereas subjects in the AO group (n = 8) received similar verbal coaching cues and physical practice but also observed a video of a skilled model before performing each set. Kinematic data were collected from video recordings of subjects who were fitted with joint center markings during testing, whereas kinetic data were collected from a weightlifting analyzer attached to the barbell. Subjects were tested before intervention, at the end of weeks 2 and 3, and at after intervention at the end of week 4. Faster improvements (3%) were observed in power clean technique with AO-facilitated learning in the first week and performance improvements (mean peak power of the subject's 15 repetitions) over time were significant (p < 0.001). In addition, performance improvement was significantly associated (R = 0.215) with technique improvements. In conclusion, AO combined with verbal coaching and physical practice of the power clean exercise resulted in significantly faster technique improvements and improvement in performance compared with traditional coaching methods.

  6. Aging of clean foams

    NASA Astrophysics Data System (ADS)

    Weon, Byung Mook; Stewart, Peter S.

    2014-11-01

    Aging is an inevitable process in living systems. Here we show how clean foams age with time through sequential coalescence events: in particular, foam aging resembles biological aging. We measure population dynamics of bubbles in clean foams through numerical simulations with a bubble network model. We demonstrate that death rates of individual bubbles increase exponentially with time, independent on initial conditions, which is consistent with the Gompertz mortality law as usually found in biological aging. This consistency suggests that clean foams as far-from-equilibrium dissipative systems are useful to explore biological aging. This work (NRF-2013R1A22A04008115) was supported by Mid-career Researcher Program through NRF grant funded by the MEST.

  7. Cleanliness audit of clinical surfaces and equipment: who cleans what?

    PubMed

    Anderson, R E; Young, V; Stewart, M; Robertson, C; Dancer, S J

    2011-07-01

    Current guidelines recommend regular cleaning of clinical equipment. We monitored items on a surgical ward for predominant user, hand-touch frequency, cleaning responsibilities and measurement of organic soil. Equipment was assessed in triplicate against a cleanliness benchmark of 100 relative light units (RLU) using the Hygiena® ATP system. There were 44 items, of which 21 were cleaned by clinical support workers (CSWs), five by domestic staff; three by nurses, three by doctors, and 12 with no designated cleaning responsibility. Geometric mean RLUs ranged from 60 to 550/100 cm² for small items such as hand-gel containers, bed control, blood pressure cuff and clinical notes; with similar values of 80-540/100 cm² RLU for larger items such as electrocardiogram machine, defibrillator, trolleys and tables. Overall geometric mean was 249/100 cm² RLU for all surfaces, with 84% (37 of 44) items exceeding the 100RLU benchmark. Of 27 items cleaned by clinical staff, 24 (89%) failed the benchmark. Of 12 sites with no cleaning specification, 11 (92%) failed the benchmark. Three of seven 'clean' sites (<100/100 cm² RLU) were cleaned by domestic staff. Average log(10) RLU of surfaces cleaned by domestics were 64% lower compared with surfaces cleaned by CSWs (95% confidence interval: 35%, 80%; P=0.019). In conclusion, clinical equipment frequently demonstrates high levels of organic soil, whether or not items have assigned cleaning responsibility. These findings suggest that cleaning practices for clinical equipment may require review, along with education of staff with specific cleaning responsibilities. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. A climate risk assessment of clean water supply in an urban area: A case study of South Tangerang city, Indonesia

    NASA Astrophysics Data System (ADS)

    Nastiti, S. I. W.; Kusnoputranto, H.; Boer, R.; Utomo, S. W.

    2018-03-01

    The demand for clean water in South Tangerang, Indonesia, is very high. At present, this demand is mostly met by groundwater that is much influenced by climate variability, land cover change, and human activities. The local company on water services (PDAM) provides clean water services for only about 9% of the population. The climate risk assessment conducted by South Tangerang Government in 2016 indicates that several areas are potentially exposed to a high risk of climate change. Survey and in-depth interview with communities and sectoral officers suggest that a risk to clean water supply in this city is increasing. This study aims to assess climate potential risks on clean water supply based on the 2016 study. We adopted the method of that study by modifying some of the vulnerability indicators that can represent clean water access and supply. The results of the study demonstrate that many wards in South Tangerang would be exposed to high climate risks of clean water supply. By 2021, about 54% of wards would be exposed from high to the very very high risk of clean water supply. These results signify the tangible need of adaptation actions, to prevent the worsening impacts of climate on clean water supply.

  9. Self-cleaning of superhydrophobic surfaces by self-propelled jumping condensate

    PubMed Central

    Wisdom, Katrina M.; Qu, Xiaopeng; Liu, Fangjie; Watson, Gregory S.; Chen, Chuan-Hua

    2013-01-01

    The self-cleaning function of superhydrophobic surfaces is conventionally attributed to the removal of contaminating particles by impacting or rolling water droplets, which implies the action of external forces such as gravity. Here, we demonstrate a unique self-cleaning mechanism whereby the contaminated superhydrophobic surface is exposed to condensing water vapor, and the contaminants are autonomously removed by the self-propelled jumping motion of the resulting liquid condensate, which partially covers or fully encloses the contaminating particles. The jumping motion off the superhydrophobic surface is powered by the surface energy released upon coalescence of the condensed water phase around the contaminants. The jumping-condensate mechanism is shown to spontaneously clean superhydrophobic cicada wings, where the contaminating particles cannot be removed by gravity, wing vibration, or wind flow. Our findings offer insights for the development of self-cleaning materials. PMID:23630277

  10. Cleaning of titanium substrates after application in a bioreactor.

    PubMed

    Fingerle, Mathias; Köhler, Oliver; Rösch, Christina; Kratz, Fabian; Scheibe, Christian; Davoudi, Neda; Müller-Renno, Christine; Ziegler, Christiane; Huster, Manuel; Schlegel, Christin; Ulber, Roland; Bohley, Martin; Aurich, Jan C

    2015-03-10

    Plain and microstructured cp-titanium samples were studied as possible biofilm reactor substrates. The biofilms were grown by exposition of the titanium samples to bacteria in a flow cell. As bacteria the rod shaped gram negative Pseudomonas fluorescens and the spherical gram negative Paracoccus seriniphilus were chosen. Afterward, the samples were cleaned in subsequent steps: First, with a standard solvent based cleaning procedure with acetone, isopropanol, and ultrapure water and second by oxygen plasma sputtering. It will be demonstrated by means of x-ray photoelectron spectroscopy, fluorescence microscopy, and confocal laser scanning microscopy that oxygen plasma cleaning is a necessary and reliant tool to fully clean and restore titanium surfaces contaminated with a biofilm. The microstructured surfaces act beneficial to biofilm growth, while still being fully restorable after biofilm contamination. Scanning electron microscopy images additionally show, that the plasma process does not affect the microstructures. The presented data show the importance of the cleaning procedure. Just using solvents does not remove the biofilm and all its components reliably while a cleaning process by oxygen plasma regenerates the surfaces.

  11. Clean fuel for demanding environmental markets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Josewicz, W.; Natschke, D.E.

    1995-12-31

    Acurex Environmental Corporation is bringing Clean Fuel to the environmentally demand Krakow market, through the cooperative agreement with the U.S. Department of Energy. Clean fuel is a proprietary clean burning coal-based energy source intended for use in stoves and hand stoked boilers. Clean Fuel is a home heating fuel that is similar in form and function to raw coal, but is more environmentally friendly and lower in cost. The heating value of Clean Fuel is 24,45 kJ/kg. Extensive sets of confirmation runs were conducted in the Academy of Mining and Metallurgy in the Krakow laboratories. It demonstrated up to 54more » percent reduction of particulate matter emission, up to 35 percent reduction of total hydrocarbon emissions. Most importantly, polycyclic aromatic hydrocarbons (toxic and carcinogens compounds) emissions were reduced by up to 85 percent, depending on species measured. The above comparison was made against premium chunk coal that is currently available in Krakow for approximately $83 to 93/ton. Clean Fuel will be made available in Krakow at a price approximately 10 percent lower than that of the premium chunk coal.« less

  12. Fabric filter model sensitivity analysis. Final report Jun 1978-Feb 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis, R.; Klemm, H.A.; Battye, W.

    1979-04-01

    The report gives results of a series of sensitivity tests of a GCA fabric filter model, as a precursor to further laboratory and/or field tests. Preliminary tests had shown good agreement with field data. However, the apparent agreement between predicted and actual values was based on limited comparisons: validation was carried out without regard to optimization of the data inputs selected by the filter users or manufactures. The sensitivity tests involved introducing into the model several hypothetical data inputs that reflect the expected ranges in the principal filter system variables. Such factors as air/cloth ratio, cleaning frequency, amount of cleaning,more » specific resistence coefficient K2, the number of compartments, and inlet concentration were examined in various permutations. A key objective of the tests was to determine the variables that require the greatest accuracy in estimation based on their overall impact on model output. For K2 variations, the system resistance and emission properties showed little change; but the cleaning requirement changed drastically. On the other hand, considerable difference in outlet dust concentration was indicated when the degree of fabric cleaning was varied. To make the findings more useful to persons assessing the probable success of proposed or existing filter systems, much of the data output is presented in graphs or charts.« less

  13. RECOVERY POTENTIAL AS A MEANS OF PRIORITIZING RESTORATION OF WATERS IDENTIFIED AS IMPAIRED UNDER THE CLEAN WATER ACT

    EPA Science Inventory

    The sheer number of waterbodies identified as impaired under Section 303(d) of the Clean Water Act presents states with challenging decisions on which sites to address, in what order, and with what fraction of limited restoration resources. Our goal was to demonstrate a systemat...

  14. 40 CFR 63.4541 - How do I demonstrate initial compliance with the emission limitations?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... no thinner and/or other additive, or cleaning material that contains organic HAP as determined... organic HAP content of coatings, thinners and/or other additives, and cleaning materials that are... volatile matter and use that value as a substitute for mass fraction of organic HAP. For reactive adhesives...

  15. 40 CFR 63.4541 - How do I demonstrate initial compliance with the emission limitations?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... no thinner and/or other additive, or cleaning material that contains organic HAP as determined... organic HAP content of coatings, thinners and/or other additives, and cleaning materials that are... volatile matter and use that value as a substitute for mass fraction of organic HAP. For reactive adhesives...

  16. Tonopah Test Range Air Monitoring: CY2015 Meteorological, Radiological, and Airborne Particulate Observations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nikolich, George; Shadel, Craig; Chapman, Jenny

    2016-09-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). The operation resulted in radionuclide-contaminated soils at the Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III, and at the TTR Sandia National Laboratories (SNL) Range Operations Control (ROC) center. The primary objective ofmore » the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites. Radionuclide assessment of airborne particulates in 2015 found the gross alpha and gross beta values of dust collected from the filters at the monitoring stations are consistent with background conditions. The meteorological and particle monitoring indicate that conditions for wind-borne contaminant movement exist at the Clean Slate sites and that, although the transport of radionuclide-contaminated soil by suspension has not been detected, movement by saltation is occurring.« less

  17. Injection Drug Users' Perceived Barriers to Using Self-Initiated Harm Reduction Strategies.

    PubMed

    Bonar, Erin E; Rosenberg, Harold

    2014-08-01

    Increasing the frequency with which injecting drug users (IDUs) engage in self-initiated harm reduction strategies could improve their health, but few investigations have examined IDUs' perceived barriers to engaging in these behaviors. We interviewed 90 IDUs recruited from needle exchanges to assess: a) perceived obstacles to their use of two specific harm reduction strategies (i.e., test shots and pre-injection skin cleaning) designed to reduce two unhealthy outcomes (i.e., overdose and bacterial infections, respectively) and b) their use of other risk-reduction practices. The most frequently cited barrier for both test shots and skin cleaning was being in a rush to inject one's drugs. Other, less commonly cited barriers were strategy-specific (e.g., buying drugs from a known dealer as a reason not to do a test shot; not having access to cleaning supplies as a reason not to clean skin). Regarding other risk reduction practices, participants' most frequently reported using new or clean injecting supplies and avoiding sharing needles and injecting supplies. Some, but not all, of the barriers generated by participants in our study were similar to those frequently reported in other investigations, perhaps due to differences in the type of sample recruited or in the harm reduction behaviors investigated.

  18. Injection Drug Users’ Perceived Barriers to Using Self-Initiated Harm Reduction Strategies

    PubMed Central

    Rosenberg, Harold

    2014-01-01

    Introduction and Aims Increasing the frequency with which injecting drug users (IDUs) engage in self-initiated harm reduction strategies could improve their health, but few investigations have examined IDUs’ perceived barriers to engaging in these behaviors. Method We interviewed 90 IDUs recruited from needle exchanges to assess: a) perceived obstacles to their use of two specific harm reduction strategies (i.e., test shots and pre-injection skin cleaning) designed to reduce two unhealthy outcomes (i.e., overdose and bacterial infections, respectively) and b) their use of other risk-reduction practices. Results The most frequently cited barrier for both test shots and skin cleaning was being in a rush to inject one’s drugs. Other, less commonly cited barriers were strategy-specific (e.g., buying drugs from a known dealer as a reason not to do a test shot; not having access to cleaning supplies as a reason not to clean skin). Regarding other risk reduction practices, participants’ most frequently reported using new or clean injecting supplies and avoiding sharing needles and injecting supplies. Discussion and Conclusions Some, but not all, of the barriers generated by participants in our study were similar to those frequently reported in other investigations, perhaps due to differences in the type of sample recruited or in the harm reduction behaviors investigated. PMID:25419201

  19. Evaluating Device Design and Cleanability of Orthopedic Device Models Contaminated with a Clinically Relevant Bone Test Soil.

    PubMed

    Lucas, Anne D; Nagaraja, Srinidhi; Gordon, Edward A; Hitchins, Victoria M

    2015-01-01

    Reusable medical devices need to be cleaned prior to disinfection or sterilization and subsequent use to prevent infections. The cleanability of medical devices depends in part on the design of the device. This study examined how models of orthopedic medical devices of increasing complexity retain calcium phosphate bone cement, a relevant test soil for these devices. The dye Alizarin Red S and micro-computed tomography (μCT) were used to assess the amount and location of bone cement debris in a series of model orthopedic devices. Testing was performed after soiling and cleaning once, and soiling and cleaning 10 times. The color change of the dye after reacting with the bone cement was useful for indicating the presence of bone cement in these models. High-resolution μCT analysis provided the volume and location of the bone cement. Models that were more complex retained significantly more bone debris than simpler designs. Model devices repeatedly soiled and cleaned 10 times retained significantly more bone debris than those soiled and cleaned once. Significantly more bone cement was retained in the more complex lumen structures. This information may be useful in designing reusable orthopedic devices, and other complex medical devices with lumens.

  20. The Use of HFC (CFC Free) Processes at the NASA Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Ross, Richard H.

    1997-01-01

    The search for ozone depleting alternative chemicals was heightened when, in 1990, the more than 65 countries that had signed the Montreal Protocol agreed to phase out completely by the year 2000. In 1992, then-president Bush advanced this date for the United States to January l, 1996. In 1991, it was realized that the planned phase out and eventual elimination of ozone depleting chemicals imposed by the Montreal Protocol and the resulting Clean Air Act (CAA) amendments would impact the cleaning and testing of aerospace hardware at the NASA Stennis Space Center. Because of this regulation, the Test & Engineering Sciences Laboratory has been working on solvent conversion studies to replace CFC-113. Aerospace hardware and test equipment used in rocket propulsion systems require extreme cleanliness levels to function and maintain their integrity. Because the cleanliness of aerospace hardware will be affected by the elimination of CFC-113; alternate cleaning technologies, including the use of fluoridated solvents have been studied as potential replacements. Several aqueous processes have been identified for cleaning moderately sized components. However, no known aqueous alternative exists for cleaning and validating T&ME and complex geometry based hardware. This paper discusses the choices and the methodologies that were used to screen potential alternatives to CFC-113.

  1. Hyper-X Stage Separation Wind Tunnel Test Program

    NASA Technical Reports Server (NTRS)

    Woods, W. C.; Holland, S. D.; DiFulvio, M.

    2000-01-01

    NASA's Hyper-X research program was developed primarily to flight demonstrate a supersonic combustion ramjet engine, fully integrated with a forebody designed to tailor inlet flow conditions and a free expansion nozzle/afterbody to produce positive thrust at design flight conditions. With a point-designed propulsion system, the vehicle must depend upon some other means for boost to its design flight condition. Clean separation from this initial propulsion system stage within less than a second is critical to the success of the flight. This paper discusses the early planning activity, background, and chronology that developed the series of wind tunnel tests to support multi degree of freedom simulation of the separation process. Representative results from each series of tests are presented and issues and concerns during the process and current status will be highlighted.

  2. Hyper-X Stage Separation Wind-Tunnel Test Program

    NASA Technical Reports Server (NTRS)

    Woods, William C.; Holland, Scott D.; DiFulvio, Michael

    2001-01-01

    NASA's Hyper-X research program was developed primarily to flight demonstrate a supersonic combustion ramjet engine, fully integrated with a forebody designed to tailor inlet flow conditions and a free expansion nozzle/afterbody to produce positive thrust at design flight conditions. With a point-designed propulsion system the vehicle must depend on some other means for boost to its design flight condition. Clean separation from this initial propulsion system stage within less than a second is critical to the success of the flight. This paper discusses the early planning activity, background, and chronology that developed the series of wind-tunnel tests to support multi-degree-of-freedom simulation of the separation process. Representative results from each series of tests are presented, and issues and concerns during the process and current status are highlighted.

  3. Hyper-X Storage Separation Wind Tunnel Test Program

    NASA Technical Reports Server (NTRS)

    Woods, William C.; Holland, Scott D.; Difulvio, Michael

    2000-01-01

    NASA's Hyper-X research program was developed primarily to flight demonstrate a supersonic combustion ramjet engine, fully integrated with a forebody designed to tailor inlet flow, conditions and a free expansion nozzle/afterbody to produce positive thrust at design flight conditions. With a point-designed propulsion system, the vehicle must depend upon some other means for boost to its design flight condition. Clean separation from this initial propulsion system stage within less than a second is critical to the success of the flight. This paper discusses the early planning activity, background, and chronology that developed the series of wind tunnel tests to support multi degree of freedom simulation of the separation process. Representative results from each series of tests are presented and issues and concerns during the process and current status will be highlighted.

  4. Glow discharge cleaning of vacuum switch tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hayashi, T.; Toya, H.

    1991-10-01

    This paper reports that glow discharge cleaning has ben advancing as a means of degassing vacuum chambers constructed for a large accelerator or for nuclear fusion research. To clean the whole surface of parts inside a vacuum switch tube (VST), a new technique is tried which generates glow discharge between the inner electrodes and copper grid surrounding it. Photographic observation reveals that the glow discharge spreads out and cleans the whole surface inside the VST. A breakdown test between the inner electrodes shows the effect of the cleaning with this technique. Higher breakdown voltage between the inner electrodes is attainedmore » by performing this glow discharge cleaning in argon rather than hydrogen gas. The difference of the cleaning effect seems to be attributed to that of the energy transfer from ion species to the absorbed molecules and microprotrusions on the surfaces.« less

  5. Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials

    NASA Technical Reports Server (NTRS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  6. Evaluation of Solvent Alternatives for Cleaning of Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Beeson, Harold; Biesinger, Paul; Delgado, Rafael; Antin, Neil

    1999-01-01

    The NASA White Sands Test Facility (WSTF) in a joint program with the Naval Sea Systems Command has evaluated a number of solvents as alternatives to the use of chlorofluorocarbons currently utilized for cleaning of oxygen systems. Particular attention has been given to the cleaning of gauges and instrumentation used in oxygen service, since there have been no identified aqueous alternatives. The requirements identified as selection criteria, include toxicity, physical properties consistent with application, flammability, oxygen compatibility, and cleaning ability. This paper provides a summary of results and recommendations for solvents evaluated to date.

  7. Cleaning procedure for improved photothermal background of toroidal optical microresonators

    NASA Astrophysics Data System (ADS)

    Horak, Erik H.; Knapper, Kassandra A.; Heylman, Kevin D.; Goldsmith, Randall H.

    2016-09-01

    High Q-factors and small mode volumes have made toroidal optical microresonators exquisite sensors to small shifts in the effective refractive index of the WGM modes. Eliminating contaminants and improving quality factors is key for many different sensing techniques, and is particularly important for photothermal imaging as contaminants add photothermal background obscuring objects of interest. Several different cleaning procedures including wet- and dry-chemical procedures are tested for their effect on Q-factors and photothermal background. RCA cleaning was shown to be successful in contrast to previously described acid cleaning procedures, most likely due to the different surface reactivity of the acid reagents used. UV-ozone cleaning was shown to be vastly superior to O2 plasma cleaning procedures, significantly reducing the photothermal background of the resonator.

  8. Characterization of Cleaning and Disinfecting Tasks and Product Use Among Hospital Occupations

    PubMed Central

    Saito, Rena; Virji, M. Abbas; Henneberger, Paul K.; Humann, Michael J.; LeBouf, Ryan F.; Stanton, Marcia L.; Liang, Xiaoming; Stefaniak, Aleksandr B.

    2016-01-01

    Background Healthcare workers have an elevated prevalence of asthma and related symptoms associated with the use of cleaning/disinfecting products. The objective of this study was to identify and characterize cleaning/disinfecting tasks and products used among hospital occupations. Methods Workers from 14 occupations at five hospitals were monitored for 216 shifts, and work tasks and products used were recorded at five-minute intervals. The major chemical constituents of each product were identified from safety data sheets. Results Cleaning and disinfecting tasks were performed with a high frequency at least once per shift in many occupations. Medical equipment preparers, housekeepers, floor strippers/waxers, and endoscopy technicians spent on average 108–177 min/shift performing cleaning/disinfecting tasks. Many occupations used products containing amines and quaternary ammonium compounds for > 100 min/shift. Conclusions This analysis demonstrates that many occupations besides housekeeping incur exposures to cleaning/disinfecting products, albeit for different durations and using products containing different chemicals. PMID:25351791

  9. Clean access platform for orbiter

    NASA Technical Reports Server (NTRS)

    Morrison, H.; Harris, J.

    1990-01-01

    The design of the Clean Access Platform at the Kennedy Space Center, beginning with the design requirements and tracing the effort throughout development and manufacturing is described. Also examined are: (1) A system description; (2) Testing requirements and conclusions; (3) Safety and reliability features; (4) Major problems experienced during the project; and (5) Lessons learned, including features necessary for the effective design of mechanisms used in clean systems.

  10. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... percent wood wastes, clean lumber and/or yard waste? (a) After the date the initial test for opacity is...

  11. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... percent wood wastes, clean lumber and/or yard waste? (a) After the date the initial test for opacity is...

  12. Proceedings of the fifteenth DOE nuclear air cleaning conference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    First, M.W.

    1979-02-01

    Papers presented are grouped under the following topics: noble gas separation, damage control, aerosols, test methods, new air cleaning technology from Europe, open-end, and filtration. A separate abstract was prepared for each paper.

  13. MTU America Inc. Clean Air Act Settlement

    EPA Pesticide Factsheets

    The settlement resolves an enforcement action by EPA and the U.S. Department of Justice against MTU for Clean Air Act (CAA) violations involving MTU’s failure to comply with certain testing, certification and reporting.

  14. Cast erosion from the cleaning of debris after the use of a cast trimmer.

    PubMed

    Hansen, Paul A; Beatty, Mark W

    2017-02-01

    Whether using tap water to rinse off debris will make a clinical difference to the surface detail of a gypsum cast is unknown. In addition, how best to remove debris from the cast is unknown. The purpose of this in vitro study was to evaluate the efficiency of different methods of cleaning a gypsum cast after trimming and the effect of short-term exposure to tap water on the surface quality of the cast. A die fitting American National Standards Institute/American Dental Association specification 25 (International Standards Organization specification 6873) for dental gypsum products was embedded in a Dentoform with the machined lines positioned at the same level as the occlusal surface of the posterior teeth. A flat plate was used to ensure that the plane of occlusion for the die was at the same position as the posterior teeth. Forty polyvinyl siloxane impressions of the Dentoform were made and poured with vacuum-mixed improved Type IV dental stone. Each cast was inspected for the accurate reproduction of the lines. The base of the 2-stage pour was trimmed with a cast trimmer with water, and surface debris was removed by rinsing by hand under tap water for 10 seconds, by brushing the cast with a soft toothbrush for 10 seconds, or by resoaking the cast and using a soft camel hair brush in slurry water for 10 seconds. The amount of debris was evaluated on a scale of 1 to 4, and the quality of the 20-μm line was evaluated on a scale of 1 to 4 under ×15 magnification. The nonparametric Kruskal-Wallis ranks test was used to identify significant differences among the different cleaning methods (α=.05). Results of the Kruskal-Wallis and Kruskal-Wallis Z-value tests demonstrated that all cleaning methods produced cleaner casts than were observed for uncleansed controls (P<.001), but no differences in debris removal were found among the different cleaning methods (.065≤P≤.901). The ability to see the quality of a 20-μm line (P=.974) was not statistically different among the groups. Rinsing the cast under flowing tap water and brushing, or hand washing under flowing tap water, or using a soft camel hair brush in slurry water for 10 seconds had no noticeable effects on the quality of a 20-μm line, and all 3 methods resulted in a clean cast. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. Impact of education on interdental cleaning behaviour based on the transtheoretical model.

    PubMed

    Hashemian, Masomeh; Fallahi, Arezoo; Tavakoli, Golaleh; Zarezadeh, Yadolah; Babaki, B Nemat; Rahaei, Zohreh

    2012-01-01

    To determine the impact of education on stages of change of behaviour in Iranian senior high school students for interdental cleaning based on the transtheoretical model. This experimental study took place from April to November 2010. 306 students were selected by multistage cluster sampling and placed into two groups: control (153 students) and intervention (153 students). Appropriate instruments and the intervention programme were designed with the purpose of improving stages of interdental cleaning behaviour, perceived benefits and self-efficacy, as well as reducing perceived barriers and gingival index (GI). The impact of the intervention programme was assessed after 24 weeks and the GI of each student was recorded for both groups before and after intervention. The data were analysed using SPSS software and the chi-square, t test, ANOVA, paired t test, Mann-Whitney U-test and sign test. The intervention had a significant, positive impact on improvement of the stages of interdental cleaning behaviour, increase in self-efficacy, perceived benefits, decrease in perceived barriers and improvement of GI (P < 0.001). After the intervention, the average grades of self-efficacy, perceived barriers and perceived benefits in the control group vs the intervention group were significantly different (P < 0.001 to 0.01). The programme was found to positively influence the stages of change and potential indicators of interdental cleaning behaviour and GI. It is suggested that this model be used for interventions in the other population groups.

  16. Cage Change Influences Serum Corticosterone and Anxiety-Like Behaviors in the Mouse

    PubMed Central

    Rasmussen, Skye; Miller, Melinda M.; Filipski, Sarah B.; Tolwani, Ravi J.

    2011-01-01

    Environmental variables and husbandry practices can influence physiology and alter behavior in mice. Our study evaluated the effects of cage change on serum corticosterone levels and anxiety-like behaviors in C57BL/6 male mice. We examined the effects of 3 different methods of performing cage transfer and of transferring mice to a clean or a dirty familiar cage microenvironment. The 3 different handling methods were forceps transfer, gentle transfer with gloved hands, and a passive transfer technique that did not involve active handling. Active handling methods and transfer to both clean and dirty cage microenvironments significantly increased serum corticosterone 15 min after cage change; however, at 60 min after cage change, levels were comparable to those of unmanipulated mice. Although the effects were transient, cage change altered anxiety-like behaviors in the open field when behavioral testing was performed on the same day. These results demonstrate that the timing of cage change can influence behavioral results, an effect that is an important consideration for rodent behavioral studies. PMID:21838975

  17. X-ray photoemission analysis of clean and carbon monoxide-chemisorbed platinum(111) stepped surfaces using a curved crystal

    DOE PAGES

    Walter, Andrew L.; Schiller, Frederik; Corso, Martina; ...

    2015-11-12

    Surface chemistry and catalysis studies could significantly gain from the systematic variation of surface active sites, tested under the very same conditions. Curved crystals are excellent platforms to perform such systematics, which may in turn allow to better resolve fundamental properties and reveal new phenomena. This is demonstrated here for the carbon monoxide/platinum system. We curve a platinum crystal around the high-symmetry (111) direction and carry out photoemission scans on top. This renders the spatial core-level imaging of carbon monoxide adsorbed on a 'tunable' vicinal surface, allowing a straightforward visualization of the rich chemisorption phenomenology at steps and terraces. Throughmore » such photoemission images we probe a characteristic elastic strain variation at stepped surfaces, and unveil subtle stress-release effects on clean and covered vicinal surfaces. Lastly, these results offer the prospect of applying the curved surface approach to rationally investigate the chemical activity of surfaces under real pressure conditions.« less

  18. X-ray photoemission analysis of clean and carbon monoxide-chemisorbed platinum(111) stepped surfaces using a curved crystal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walter, Andrew L.; Schiller, Frederik; Corso, Martina

    Surface chemistry and catalysis studies could significantly gain from the systematic variation of surface active sites, tested under the very same conditions. Curved crystals are excellent platforms to perform such systematics, which may in turn allow to better resolve fundamental properties and reveal new phenomena. This is demonstrated here for the carbon monoxide/platinum system. We curve a platinum crystal around the high-symmetry (111) direction and carry out photoemission scans on top. This renders the spatial core-level imaging of carbon monoxide adsorbed on a 'tunable' vicinal surface, allowing a straightforward visualization of the rich chemisorption phenomenology at steps and terraces. Throughmore » such photoemission images we probe a characteristic elastic strain variation at stepped surfaces, and unveil subtle stress-release effects on clean and covered vicinal surfaces. Lastly, these results offer the prospect of applying the curved surface approach to rationally investigate the chemical activity of surfaces under real pressure conditions.« less

  19. Towards Self-Clocked Gated OCDMA Receiver

    NASA Astrophysics Data System (ADS)

    Idris, S.; Osadola, T.; Glesk, I.

    2013-02-01

    A novel incoherent OCDMA receiver with incorporated all-optical clock recovery for self-synchronization of a time gate for the multi access interferences (MAI) suppression and minimizing the effect of data time jitter in incoherent OCDMA system was successfully developed and demonstrated. The solution was implemented and tested in a multiuser environment in an out of the laboratory OCDMA testbed with two-dimensional wavelength-hopping time-spreading coding scheme and OC-48 (2.5 Gbp/s) data rate. The self-clocked all-optical time gate uses SOA-based fibre ring laser optical clock, recovered all-optically from the received OCDMA traffic to control its switching window for cleaning the autocorrelation peak from the surrounding MAI. A wider eye opening was achieved when the all-optically recovered clock from received data was used for synchronization if compared to a static approach with the RF clock being generated by a RF synthesizer. Clean eye diagram was also achieved when recovered clock is used to drive time gating.

  20. High contrast research in the Nd:glass laser system based on optical parametric amplification temporal cleaning device

    NASA Astrophysics Data System (ADS)

    Lu, Xiaoming; Leng, Yuxin; Sui, Zhan; Li, Yanyan; Zhang, Zongxin; Xu, Yi; Guo, Xiaoyang; Liu, Yanqi; Li, Ruxin; Xu, Zhizhan

    2014-02-01

    We demonstrate high amplified spontaneous emission (ASE) contrast pulses in a Nd:glass laser system based on the hybrid double chirped pulse amplification (double CPA) scheme. By an OPA temporal cleaning device, ~100 uJ/46 fs/ 1011 clean pulses are generated and amplified in the next Nd:glass laser. After compressor, >150 mJ/~0.5 ps/1 Hz pulses can be obtained. The ASE temporal contrast of amplified pulses is ~1011 with energy gain ~2.5×104 in the Nd:glass amplifiers.

  1. Quiet Clean Short-haul Experimental Engine (QCSEE) under-the-wing engine composite fan blade design report

    NASA Technical Reports Server (NTRS)

    Ravenhall, R.; Salemme, C. T.

    1977-01-01

    A total of 38 quiet clean short haul experimental engine under the wing composite fan blades were manufactured for various component tests, process and tooling, checkout, and use in the QCSEE UTW engine. The component tests included frequency characterization, strain distribution, bench fatigue, platform static load, whirligig high cycle fatigue, whirligig low cycle fatigue, whirligig strain distribution, and whirligig over-speed. All tests were successfully completed. All blades planned for use in the engine were subjected to and passed a whirligig proof spin test.

  2. An energy-dispersive X-ray analysis and SEM study of debris remaining on endodontic instruments after ultrasonic cleaning and autoclave sterilization.

    PubMed

    Parirokh, Masoud; Asgary, Saeed; Eghbal, Mohammad Jafar

    2005-08-01

    This study was carried out to investigate metallic and non-metallic debris remaining on endodontic files after ultrasonic cleaning and autoclave processing. Forty-eight unused rotary and hand endodontic files, including eight different brands, were tested. Instruments were cleaned with ultrasound, autoclaved and before and after each step were observed by scanning electron microscopy (SEM). Adherent debris was analysed by energy-dispersive X-ray analysis (EDXA). All of the instruments before ultrasound cleaning were contaminated with metallic and non-metallic debris. Although most non-metallic debris was removed by ultrasonic cleaning, most of the metallic debris remained even after the final step of sterilization.

  3. Catalytic hydroprocessing of fast pyrolysis oils: Impact of biomass feedstock on process efficiency

    DOE PAGES

    Carpenter, Daniel; Westover, Tyler; Howe, Daniel; ...

    2016-12-01

    Here, we report here on an experimental study to produce refinery-ready fuel blendstocks via catalytic hydrodeoxygenation (upgrading) of pyrolysis oil using several biomass feedstocks and various blends. Blends were tested along with the pure materials to determine the effect of blending on product yields and qualities. Within experimental error, oil yields from fast pyrolysis and upgrading are shown to be linear functions of the blend components. Switchgrass exhibited lower fast pyrolysis and upgrading yields than the woody samples, which included clean pine, oriented strand board (OSB), and a mix of pinon and juniper (PJ). The notable exception was PJ, formore » which the poor upgrading yield of 18% was likely associated with the very high viscosity of the PJ fast pyrolysis oil (947 cp). The highest fast pyrolysis yield (54% dry basis) was obtained from clean pine, while the highest upgrading yield (50%) was obtained from a blend of 80% clean pine and 20% OSB (CP 8OSB 2). For switchgrass, reducing the fast pyrolysis temperature to 450 degrees C resulted in a significant increase to the pyrolysis oil yield and reduced hydrogen consumption during hydrotreating, but did not directly affect the hydrotreating oil yield. The water content of fast pyrolysis oils was also observed to increase linearly with the summed content of potassium and sodium, ranging from 21% for clean pine to 37% for switchgrass. Multiple linear regression models demonstrate that fast pyrolysis is strongly dependent upon the contents lignin and volatile matter as well as the sum of potassium and sodium.« less

  4. Requirements and Capabilities for Fielding Cryogenic DT-Containing Fill-Tube Targets for Direct-Drive Experiments on OMEGA

    DOE PAGES

    Harding, D. R.; Ulreich, J.; Wittman, M. D.; ...

    2017-12-06

    Improving the performance of direct-drive cryogenic targets at the Omega Laser Facility requires the development of a new cryogenic system to (i) field non permeable targets with a fill tube, and (ii) provide a clean environment around the target. This capability is to demonstrate that imploding a scaled-down version of the direct-drive–ignition target for the National Ignition Facility (NIF) on the OMEGA laser will generate the hot-spot pressure that is needed for ignition; this will justify future cryogenic direct-drive experiments on the NIF. The paper describes the target, the cryogenic equipment that is being constructed to achieve this goal, andmore » the proposed target delivery process. Thermal calculations, fill-tube–based target designs, and structural/vibrational analyses are provided to demonstrate the credibility of the design. This new design will include capabilities not available (or possible) with the existing OMEGA cryogenic system, with the emphasis being to preserve a pristinely clean environment around the target, and to provide upgraded diagnostics to characterize both the ice layer and the target’s surface. The conceptual design is complete and testing of prototypes and subcomponents is underway. The rationale and capabilities of the new design are discussed.« less

  5. Requirements and Capabilities for Fielding Cryogenic DT-Containing Fill-Tube Targets for Direct-Drive Experiments on OMEGA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harding, D. R.; Ulreich, J.; Wittman, M. D.

    Improving the performance of direct-drive cryogenic targets at the Omega Laser Facility requires the development of a new cryogenic system to (i) field non permeable targets with a fill tube, and (ii) provide a clean environment around the target. This capability is to demonstrate that imploding a scaled-down version of the direct-drive–ignition target for the National Ignition Facility (NIF) on the OMEGA laser will generate the hot-spot pressure that is needed for ignition; this will justify future cryogenic direct-drive experiments on the NIF. The paper describes the target, the cryogenic equipment that is being constructed to achieve this goal, andmore » the proposed target delivery process. Thermal calculations, fill-tube–based target designs, and structural/vibrational analyses are provided to demonstrate the credibility of the design. This new design will include capabilities not available (or possible) with the existing OMEGA cryogenic system, with the emphasis being to preserve a pristinely clean environment around the target, and to provide upgraded diagnostics to characterize both the ice layer and the target’s surface. The conceptual design is complete and testing of prototypes and subcomponents is underway. The rationale and capabilities of the new design are discussed.« less

  6. Are Diatoms "Green" Aluminosilicate Synthesis Microreactors for Future Catalyst Production?

    PubMed

    Köhler, Lydia; Machill, Susanne; Werner, Anja; Selzer, Carolin; Kaskel, Stefan; Brunner, Eike

    2017-12-16

    Diatom biosilica may offer an interesting perspective in the search for sustainable solutions meeting the high demand for heterogeneous catalysts. Diatomaceous earth (diatomite), i.e., fossilized diatoms, is already used as adsorbent and carrier material. While diatomite is abundant and inexpensive, freshly harvested and cleaned diatom cell walls have other advantages, with respect to purity and uniformity. The present paper demonstrates an approach to modify diatoms both in vivo and in vitro to produce a porous aluminosilicate that is serving as a potential source for sustainable catalyst production. The obtained material was characterized at various processing stages with respect to morphology, elemental composition, surface area, and acidity. The cell walls appeared normal without morphological changes, while their aluminum content was raised from the molar ratio n (Al): n (Si) 1:600 up to 1:50. A specific surface area of 55 m²/g was measured. The acidity of the material increased from 149 to 320 µmol NH₃/g by ion exchange, as determined by NH₃ TPD. Finally, the biosilica was examined by an acid catalyzed test reaction, the alkylation of benzene. While the cleaned cell walls did not catalyze the reaction at all, and the ion exchanged material was catalytically active. This demonstrates that modified biosilica does indeed has potential as a basis for future catalytically active materials.

  7. Alkali-assisted membrane cleaning for fouling control of anaerobic ceramic membrane bioreactor.

    PubMed

    Mei, Xiaojie; Quek, Pei Jun; Wang, Zhiwei; Ng, How Yong

    2017-09-01

    In this study, a chemically enhanced backflush (CEB) cleaning method using NaOH solution was proposed for fouling mitigation in anaerobic membrane bioreactors (AnMBRs). Ex-situ cleaning tests revealed that NaOH dosages ranging from 0.05 to 1.30mmol/L had positive impacts on anaerobic biomass, while higher dosages (>1.30mmol/L) showed inhibition and/or toxic impacts. In-situ cleaning tests showed that anaerobic biomass could tolerate much higher NaOH concentrations due to the alkali consumption by anaerobic process and/or the buffering role of mixed liquor. More importantly, 10-20mmol-NaOH/L could significantly reduce membrane fouling rates (4-5.5 times over the AnMBR with deionized water backflush) and slightly improve methanogenic activities. COD removal efficiencies were over 87% and peaked at 20mmol-NaOH/L. However, extremely high NaOH concentration had adverse effects on filtration and treatment performance. Economic analysis indicated that 12mmol/L of NaOH was the cost-efficient and optimal fouling-control dosage for the CEB cleaning. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Aqueous Cleaning and Validation for Space Shuttle Propulsion Hardware at the White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Hornung, Steven D.; Biesinger, Paul; Kirsch, Mike; Beeson, Harold; Leuders, Kathy

    1999-01-01

    The NASA White Sands Test Facility (WSTF) has developed an entirely aqueous final cleaning and verification process to replace the current chlorofluorocarbon (CFC) 113 based process. This process has been accepted for final cleaning and cleanliness verification of WSTF ground support equipment. The aqueous process relies on ultrapure water at 50 C (323 K) and ultrasonic agitation for removal of organic compounds and particulate. The cleanliness is verified bv determining the total organic carbon (TOC) content and filtration with particulate counting. The effectiveness of the aqueous methods for detecting hydrocarbon contamination and particulate was compared to the accepted CFC 113 sampling procedures. Testing with known contaminants, such as hydraulic fluid and cutting and lubricating oils, to establish a correlation between aqueous TOC and CFC 113 nonvolatile residue (NVR) was performed. Particulate sampling on cleaned batches of hardware that were randomly separated and sampled by the two methods was performed. This paper presents the approach and results, and discusses the issues in establishing the equivalence of aqueous sampling to CFC 113 sampling, while describing the approach for implementing aqueous techniques on Space Shuttle Propulsion hardware.

  9. Life of Pennzane and 815Z-Lubricated Instrument Bearings Cleaned with Non-CFC Solvents

    NASA Technical Reports Server (NTRS)

    Loewenthal, Stuart; Jones, William; Predmore, Roamer

    1999-01-01

    This report takes the form of two papers: (1) "Life of Pennzane and 815Z-Lubricated Instrument Bearings cleaned with Non-CFC Solvents" and (2) a published paper, entitled "Instrument bearing life with NON-CFC cleaners". Abstract for paper # 1 : Bearings used in spacecraft mechanisms have historically been cleaned with chlorofluorocarbon CFC-1 13 (Freon) solvents and lubricated with a perfluorinated polyalkylether (PFPE) oils like 815-Z. Little full-scale bearing life test data exists to evaluate the effects of the newer class environmental-friendly bearing cleaners or improved synthetic hydrocarbon space oils like Pennzane. To address the lack of data, a cooperative, bearing life test program was initiated between NASA, Lockheed Martin and MPB. The objective was to obtain comparative long-term, life test data for flight-quality bearings, cleaned with non-CFC solvents versus CFC-1 13 under flight-like conditions with two space oils. A goal was to gain a better understanding of the lubricant surface chemistry effects with such solvents. A second objective was to obtain well-controlled, full-scale bearing life test data with a relatively new synthetic oil (Pennzane), touted as an improvement to Bray 815Z, an oil with considerable space flight history. The second paper, which serves as an attachment, is abstracted below: Bearings used in spacecraft mechanisms have historically been cleaned with chlorofluorocarbon CFC-113 (Freon) solvents and lubricated with a perfluorinated polyalkylether (PFPE) oils like 815-Z. Little full-scale bearing life test data exists to evaluate the effects of the newer class environmental-friendly bearing cleaners or improved synthetic hydrocarbon space oils like Pennzane. To address the lack of data, a cooperative, bearing life test program was initiated between NASA, Lockheed Martin and MPB. The objective was to obtain comparative long-term, life test data for flight-quality bearings, cleaned with non-CFC solvents versus CFC-1 13 under flight-like conditions with two space oils. A goal was to gain a better understanding of the lubricant surface chemistry effects with such solvents. A second objective was to obtain well-controlled, full-scale bearing life test data with a relatively new synthetic oil (Pennzane), touted as an improvement to Bray 815Z, an oil with considerable space flight history.

  10. CSTT Update: Fuel Quality Analyzer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brosha, Eric L.; Lujan, Roger W.; Mukundan, Rangachary

    These are slides from a presentation. The following topics are covered: project background (scope and approach), developing the prototype (timeline), update on intellectual property, analyzer comparisons (improving humidification, stabilizing the baseline, applying clean-up strategy, impact of ionomer content and improving clean-up), proposed operating mode, considerations for testing in real-world conditions (Gen 1 analyzer electronics development, testing partner identified, field trial planning), summary, and future work.

  11. Automated processing of endoscopic surgical instruments.

    PubMed

    Roth, K; Sieber, J P; Schrimm, H; Heeg, P; Buess, G

    1994-10-01

    This paper deals with the requirements for automated processing of endoscopic surgical instruments. After a brief analysis of the current problems, solutions are discussed. Test-procedures have been developed to validate the automated processing, so that the cleaning results are guaranteed and reproducable. Also a device for testing and cleaning was designed together with Netzsch Newamatic and PCI, called TC-MIC, to automate processing and reduce manual work.

  12. New cleaning technologies advance coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onursal, B.

    1984-05-01

    Alternative options are discussed for reducing sulfur dioxide emissions from coal burning utility and industrial sources. Test results indicate that it may be most advantageous to use the AED Process after coal preparation or on coals that do not need much ash removal. However, the developer claims that research efforts after 1981 have led to process improvements for producing clean coals containing 1.5% to 3% ash. This paper describes the test facility where a full-scale test of the AED Process is underway.

  13. Characterization of irradiated AISI 316L stainless steel disks removed from the Spallation Neutron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vevera, Bradley J; Hyres, James W; McClintock, David A

    2014-01-01

    Irradiated AISI 316L stainless steel disks were removed from the Spallation Neutron Source (SNS) for post-irradiation examination (PIE) to assess mechanical property changes due to radiation damage and erosion of the target vessel. Topics reviewed include high-resolution photography of the disk specimens, cleaning to remove mercury (Hg) residue and surface oxides, profile mapping of cavitation pits using high frequency ultrasonic testing (UT), high-resolution surface replication, and machining of test specimens using wire electrical discharge machining (EDM), tensile testing, Rockwell Superficial hardness testing, Vickers microhardness testing, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The effectiveness of the cleaning proceduremore » was evident in the pre- and post-cleaning photography and permitted accurate placement of the test specimens on the disks. Due to the limited amount of material available and the unique geometry of the disks, machine fixturing and test specimen design were critical aspects of this work. Multiple designs were considered and refined during mock-up test runs on unirradiated disks. The techniques used to successfully machine and test the various specimens will be presented along with a summary of important findings from the laboratory examinations.« less

  14. Design of underwater superoleophobic TiO{sub 2} coatings with additional photo-induced self-cleaning properties by one-step route bio-inspired from fish scales

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hao; Guo, Zhiguang, E-mail: zguo@licp.cas.cn; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000

    Self-cleaning properties inspired by the structures and functions of some creatures are of great interest since the late 20th century. In this paper, TiO{sub 2} coatings with hierarchical rutile TiO{sub 2} flowers on fluorine-doped tin oxide substrate are fabricated through a simple one-step hydrothermal method. The flower-like coatings exhibit superhydrophilicity in air and superoleophobicity underwater with a contact angle as high as 157°, presenting good underwater self-cleaning performance. In addition, when contaminated by oleic acid, the as-prepared TiO{sub 2} coatings also exhibit excellent photocatalytic capability under ultraviolet irradiation, which demonstrated self-cleaning properties in a different way. This self-cleaning film providesmore » a good strategy for some industrial and ocean applications.« less

  15. National Renewable Energy Laboratory (NREL) Topic 2 Final Report: End-to-End Communication and Control System to Support Clean Energy Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hudgins, Andrew P.; Carrillo, Ismael M.; Jin, Xin

    This document is the final report of a two-year development, test, and demonstration project, 'Cohesive Application of Standards- Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL's) Integrated Network Testbed for Energy Grid Research and Technology (INTEGRATE) initiative hosted at Energy Systems Integration Facility (ESIF). This project demonstrated techniques to control distribution grid events using the coordination of traditional distribution grid devices and high-penetration renewable resources and demand response. Using standard communication protocols and semantic standards, the project examined the use cases of high/low distribution voltage, requests for volt-ampere-reactive (VAR)more » power support, and transactive energy strategies using Volttron. Open source software, written by EPRI to control distributed energy resources (DER) and demand response (DR), was used by an advanced distribution management system (ADMS) to abstract the resources reporting to a collection of capabilities rather than needing to know specific resource types. This architecture allows for scaling both horizontally and vertically. Several new technologies were developed and tested. Messages from the ADMS based on the common information model (CIM) were developed to control the DER and DR management systems. The OpenADR standard was used to help manage grid events by turning loads off and on. Volttron technology was used to simulate a homeowner choosing the price at which to enter the demand response market. Finally, the ADMS used newly developed algorithms to coordinate these resources with a capacitor bank and voltage regulator to respond to grid events.« less

  16. Survival of Salmonella Copenhagen in food bowls following contamination with experimentally inoculated raw meat: Effects of time, cleaning, and disinfection

    PubMed Central

    Weese, J Scott; Rousseau, J.

    2006-01-01

    There are concerns regarding the safety of feeding raw meat to household pets. This study demonstrated that Salmonella persists in food bowls that are inoculated with Salmonella-containing raw meat. Standard methods of cleaning and disinfection were minimally effective at eliminating Salmonella contamination. PMID:17017654

  17. Education and Labor Market Risk: Understanding the Role of Data Cleaning

    ERIC Educational Resources Information Center

    Whalley, Alexander

    2011-01-01

    This paper examines whether conclusions about the relationship between education and labor market risk depend on the use of commonly applied procedures to clean data of extreme values. The analysis uses fifteen years of data from the Panel Study of Income Dynamics to demonstrate that conclusions about the relationship between education and labor…

  18. Si /SiGe n-type resonant tunneling diodes fabricated using in situ hydrogen cleaning

    NASA Astrophysics Data System (ADS)

    Suet, Z.; Paul, D. J.; Zhang, J.; Turner, S. G.

    2007-05-01

    In situ hydrogen cleaning to reduce the surface segregation of n-type dopants in SiGe epitaxy has been used to fabricate Si /SiGe resonant tunneling diodes in a joint gas source chemical vapor deposition and molecular beam epitaxial system. Diodes fabricated without the in situ clean demonstrate linear current-voltage characteristics, while a 15min hydrogen clean produces negative differential resistance with peak-to-valley current ratios up to 2.2 and peak current densities of 5.0A/cm2 at 30K. Analysis of the valley current and the band structure of the devices suggest methods for increasing the operating temperature of Si /SiGe resonant tunneling diodes as required for applications.

  19. The model of nano-scale copper particle removal from silicon surface in high pressure CO2 + H2O and CO2 + H2O + IPA cleaning solutions.

    PubMed

    Tan, Xin; Chai, Jiajue; Zhang, Xiaogang; Chen, Jiawei

    2011-12-01

    This study focuses on the description of the static forces in CO2-H2O and CO2-H2O-IPA cleaning solutions with a separate fluid phase entrapped between nano-scale copper particles and a silicon surface. Calculations demonstrate that increasing the pressure of the cleaning system decreases net adhesion force (NAF) between the particle and silicon. The NAF of a particle for in CO2-H2O-IPA system is less than that in CO2-H2O system, suggesting that the particles enter into bulk layer more easily as the CO2-H2O cleaning system is added IPA.

  20. On-farm comparisons of different cleaning protocols in broiler houses.

    PubMed

    Luyckx, K Y; Van Weyenberg, S; Dewulf, J; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K

    2015-08-01

    The present study evaluated the effectiveness of 4 cleaning protocols designed to reduce the bacteriological infection pressure on broiler farms and prevent food-borne zoonoses. Additionally, difficult to clean locations and possible sources of infection were identified. Cleaning and disinfection rounds were evaluated in 12 broiler houses on 5 farms through microbiological analyses and adenosine triphosphate hygiene monitoring. Samples were taken at 3 different times: before cleaning, after cleaning, and after disinfection. At each sampling time, swabs were taken from various locations for enumeration of the total aerobic flora and Enterococcus species pluralis ( SPP:). In addition, before cleaning and after disinfection, testing for Escherichia coli and Salmonella was carried out. Finally, adenosine triphosphate swabs and agar contact plates for total aerobic flora counts were taken after cleaning and disinfection, respectively. Total aerobic flora and Enterococcus spp. counts on the swab samples showed that cleaning protocols which were preceded by an overnight soaking with water caused a higher bacterial reduction compared to protocols without a preceding soaking step. Moreover, soaking of broiler houses leads to less water consumption and reduced working time during high pressure cleaning. No differences were found between protocols using cold or warm water during cleaning. Drinking cups, drain holes, and floor cracks were identified as critical locations for cleaning and disinfection in broiler houses. © 2015 Poultry Science Association Inc.

  1. Alternative, Green Processes for the Precision Cleaning of Aerospace Hardware

    NASA Technical Reports Server (NTRS)

    Maloney, Phillip R.; Grandelli, Heather Eilenfield; Devor, Robert; Hintze, Paul E.; Loftin, Kathleen B.; Tomlin, Douglas J.

    2014-01-01

    Precision cleaning is necessary to ensure the proper functioning of aerospace hardware, particularly those systems that come in contact with liquid oxygen or hypergolic fuels. Components that have not been cleaned to the appropriate levels may experience problems ranging from impaired performance to catastrophic failure. Traditionally, this has been achieved using various halogenated solvents. However, as information on the toxicological and/or environmental impacts of each came to light, they were subsequently regulated out of use. The solvent currently used in Kennedy Space Center (KSC) precision cleaning operations is Vertrel MCA. Environmental sampling at KSC indicates that continued use of this or similar solvents may lead to high remediation costs that must be borne by the Program for years to come. In response to this problem, the Green Solvents Project seeks to develop state-of-the-art, green technologies designed to meet KSCs precision cleaning needs.Initially, 23 solvents were identified as potential replacements for the current Vertrel MCA-based process. Highly halogenated solvents were deliberately omitted since historical precedents indicate that as the long-term consequences of these solvents become known, they will eventually be regulated out of practical use, often with significant financial burdens for the user. Three solvent-less cleaning processes (plasma, supercritical carbon dioxide, and carbon dioxide snow) were also chosen since they produce essentially no waste stream. Next, experimental and analytical procedures were developed to compare the relative effectiveness of these solvents and technologies to the current KSC standard of Vertrel MCA. Individually numbered Swagelok fittings were used to represent the hardware in the cleaning process. First, the fittings were cleaned using Vertrel MCA in order to determine their true cleaned mass. Next, the fittings were dipped into stock solutions of five commonly encountered contaminants and were weighed again showing typical contaminant deposition levels of approximately 0.00300g per part. They were then cleaned by the solvent or process being tested and then weighed a third time which allowed for the calculation of the cleaning efficiency of the test solvent or process.Based on preliminary experiments, five solvents (ethanol, isopropanol, acetone, ethyl acetate, and tert-butyl acetate) were down selected for further testing. When coupled with ultrasonic agitation, these solvents removed hydrocarbon contaminants as well as Vertrel MCA and showed improved removal of perfluorinated greases. Supercritical carbon dioxide did an excellent job dissolving each of the five contaminants but did a poor job of removing Teflon particles found in the perfluorinated greases. Plasma cleaning efficiency was found to be dependent on which supply gas was used, exposure time, and gas pressure. Under optimized conditions it was found that breathing air, energized to the plasma phase, was able to remove nearly 100% of the contamination.These findings indicate that alternative cleaning methods are indeed able to achieve precision levels of cleanliness. Currently, our team is working with a commercial cleaning company to get independent verification of our results. We are also evaluating the technical and financial aspects of scaling these processes to a size capable of supporting the future cleaning needs of KSC.

  2. PERFORMANCE TESTING OF AIR CLEANING PRODUCTS

    EPA Science Inventory

    The paper discuses the application of the Environmental Technology Verification (ETV) Program for products that clean ventilation air to the problem of protecting buildings from chemical and biological attack. This program is funded by the U.S. Environmental Protection Agency und...

  3. Operational Testing of Floor Cleaning Cloths for Household ...

    EPA Pesticide Factsheets

    Report The objective of this study was to evaluate the Swiffer® Sweeper® floor mop system (SSFMS) as a low-tech method to clean indoor residential floors contaminated with B. anthracis spores (the causative agent of anthrax).

  4. Ultrahigh vacuum and low-temperature cleaning of oxide surfaces using a low-concentration ozone beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pratt, A.; Department of Physics, University of York, Heslington, York YO10 5DD; Graziosi, P.

    We present a novel method of delivering a low-concentration (<15%) ozone beam to an ultra-high vacuum environment for the purpose of cleaning and dosing experimental samples through oxidation processing. The system described is safe, low-cost, and practical and overcomes the limitations of ozone transport in the molecular flow environment of high or ultrahigh vacuum whilst circumventing the use of pure ozone gas which is potentially highly explosive. The effectiveness of this method in removing surface contamination is demonstrated through comparison of high-temperature annealing of a simple oxide (MgO) in ozone and oxygen environments as monitored using quadrupole mass spectroscopy andmore » Auger electron spectroscopy. Additionally, we demonstrate the potential of ozone for obtaining clean complex oxide surfaces without the need for high-temperature annealing which may significantly alter surface structure.« less

  5. Cheyletiella infestation in the dog: observations on diagnostic methods and clinical signs.

    PubMed

    Saevik, B K; Bredal, W; Ulstein, T L

    2004-10-01

    The aims of this study were to evaluate the ability of diagnostic methods to detect naturally occurring Cheyletiella infestation in dogs, and to quantify and relate the number of mites and eggs present to clinical signs. Privately owned dogs with skin problems were eligible for inclusion in the study. Four diagnostic tests were performed on each dog in the following order: tape impression, hair plucking, skin scraping and vacuum cleaning. Dogs with positive test results for Cheyletiella infestation in at least one of the tests under evaluation were included in the study (n=27). The severity of pruritus and scaling was graded on a four-point fixed scale. The diagnostic findings in vacuum cleaning samples provided a semiquantitative measure of the grade of infestation. The vacuum cleaning test gave a positive test result in all dogs and was significantly more efficient than the other tests evaluated (P<0.01). The number of diagnostic findings varied considerably among the different vacuum samples. No significant relationship between the number of diagnostic findings and severity of clinical signs was detected.

  6. Risk in cleaning: chemical and physical exposure.

    PubMed

    Wolkoff, P; Schneider, T; Kildesø, J; Degerth, R; Jaroszewski, M; Schunk, H

    1998-04-23

    Cleaning is a large enterprise involving a large fraction of the workforce worldwide. A broad spectrum of cleaning agents has been developed to facilitate dust and dirt removal, for disinfection and surface maintenance. The cleaning agents are used in large quantities throughout the world. Although a complex pattern of exposure to cleaning agents and resulting health problems, such as allergies and asthma, are reported among cleaners, only a few surveys of this type of product have been performed. This paper gives a broad introduction to cleaning agents and the impact of cleaning on cleaners, occupants of indoor environments, and the quality of cleaning. Cleaning agents are usually grouped into different product categories according to their technical functions and the purpose of their use (e.g. disinfectants and surface care products). The paper also indicates the adverse health and comfort effects associated with the use of these agents in connection with the cleaning process. The paper identifies disinfectants as the most hazardous group of cleaning agents. Cleaning agents contain evaporative and non-evaporative substances. The major toxicologically significant constituents of the former are volatile organic compounds (VOCs), defined as substances with boiling points in the range of 0 degree C to about 400 degrees C. Although laboratory emission testing has shown many VOCs with quite different time-concentration profiles, few field studies have been carried out measuring the exposure of cleaners. However, both field studies and emission testing indicate that the use of cleaning agents results in a temporal increase in the overall VOC level. This increase may occur during the cleaning process and thus it can enhance the probability of increased short-term exposure of the cleaners. However, the increased levels can also be present after the cleaning and result in an overall increased VOC level that can possibly affect the indoor air quality (IAQ) perceived by occupants. The variety and duration of the emissions depend inter alia on the use of fragrances and high boiling VOCs. Some building materials appear to increase their VOC emission through wet cleaning and thus may affect the IAQ. Particles and dirt contain a great variety of both volatile and non-volatile substances, including allergens. While the volatile fraction can consist of more than 200 different VOCs including formaldehyde, the non-volatile fraction can contain considerable amounts (> 0.5%) of fatty acid salts and tensides (e.g. linear alkyl benzene sulphonates). The level of these substances can be high immediately after the cleaning process, but few studies have been conducted concerning this problem. The substances partly originate from the use of cleaning agents. Both types are suspected to be airway irritants. Cleaning activities generate dust, mostly by resuspension, but other occupant activities may also resuspend dust over longer periods of time. Personal sampling of VOCs and airborne dust gives higher results than stationary sampling. International bodies have proposed air sampling strategies. A variety of field sampling techniques for VOC and surface particle sampling is listed.

  7. Single treatment with ethanol hand rub is ineffective against human rhinovirus--hand washing with soap and water removes the virus efficiently.

    PubMed

    Savolainen-Kopra, Carita; Korpela, Terttu; Simonen-Tikka, Marja-Leena; Amiryousefi, Ali; Ziegler, Thedi; Roivainen, Merja; Hovi, Tapani

    2012-03-01

    Ethanol-containing hand rubs are used frequently as a substitute for hand washing with water and soap. However, not all viruses are inactivated by a short term rubbing with alcohol. The capacity of a single round of instructed and controlled hand cleaning with water and soap or ethanol-containing hand rub, respectively, was tested for removal of human rhinovirus administered onto the skin of healthy volunteers on the back of the hands. Hand washing with soap and water appeared to be much more efficient for removing rhinoviruses from skin than rubbing hands with an ethanol-containing disinfectant. After washing with soap and water the virus was detected in 3/9 (33.3%) test persons from the left hand and 1/9 (11.1%) cases from the right hand, whereas the virus was detected invariably by real-time RT-PCR from both hands after cleaning with alcohol hand rub (P-value <0.01). Both substances evaluated clinically were also tested in vitro for virucidal efficacy against Human rhinovirus2 (HRV2) using a standardized assay. Both tested substances were poor within the contact time used in the hand-cleaning test. In conclusion, thorough and conventional hand washing with water and soap can clean efficiently hands contaminated with the virus responsible for an extensive share of common cold episodes. Copyright © 2012 Wiley Periodicals, Inc.

  8. QFD analysis of RSRM aqueous cleaners

    NASA Technical Reports Server (NTRS)

    Marrs, Roy D.; Jones, Randy K.

    1995-01-01

    This paper presents a Quality Function Deployment (QFD) analysis of the final down-selected aqueous cleaners to be used on the Redesigned Solid Rocket Motor (RSRM) program. The new cleaner will replace solvent vapor degreasing. The RSRM Ozone Depleting Compound Elimination program is discontinuing the methyl chloroform vapor degreasing process and replacing it with a spray-in-air aqueous cleaning process. Previously, 15 cleaners were down-selected to two candidates by passing screening tests involving toxicity, flammability, cleaning efficiency, contaminant solubility, corrosion potential, cost, and bond strength. The two down-selected cleaners were further evaluated with more intensive testing and evaluated using QFD techniques to assess suitability for cleaning RSRM case and nozzle surfaces in preparation for adhesive bonding.

  9. The cleaning and disinfection by heat of bedpans in automatic and semi-automatic machines.

    PubMed Central

    Mostafa, A. B.; Chackett, K. F.

    1976-01-01

    This work is concerned with the cleaning and disinfection by heat of stainless-steel and polypropylene bedpans, which had been soiled with either a biological contaminant, human serum albumin (HSA) labelled with technetium-99m 99m(Tc), or a bacteriological contaminant, streptococcus faecalis mixed with Tc-labelled HSA. Results of cleaning and disinfection achieved with a Test Machine and those achieved by procedures adopted in eight different wards of a general hospital are reported. Bedpan washers installed in wards were found to be less efficient than the Test Machine, at least partly because of inadequate maintenance. Stainless-steel and polypropylene bedpans gave essentially the same results. PMID:6591

  10. Accelerating Clean Energy Commercialization. A Strategic Partnership Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, Richard; Pless, Jacquelyn; Arent, Douglas J.

    Technology development in the clean energy and broader clean tech space has proven to be challenging. Long-standing methods for advancing clean energy technologies from science to commercialization are best known for relatively slow, linear progression through research and development, demonstration, and deployment (RDD&D); and characterized by well-known valleys of death for financing. Investment returns expected by traditional venture capital investors have been difficult to achieve, particularly for hardware-centric innovations, and companies that are subject to project finance risks. Commercialization support from incubators and accelerators has helped address these challenges by offering more support services to start-ups; however, more effort ismore » needed to fulfill the desired clean energy future. The emergence of new strategic investors and partners in recent years has opened up innovative opportunities for clean tech entrepreneurs, and novel commercialization models are emerging that involve new alliances among clean energy companies, RDD&D, support systems, and strategic customers. For instance, Wells Fargo and Company (WFC) and the National Renewable Energy Laboratory (NREL) have launched a new technology incubator that supports faster commercialization through a focus on technology development. The incubator combines strategic financing, technology and technical assistance, strategic customer site validation, and ongoing financial support.« less

  11. Spacecraft surgical scrub system

    NASA Technical Reports Server (NTRS)

    Abbate, M.

    1980-01-01

    Ease of handling and control in zero gravity and minimizing the quantity of water required were prime considerations. The program tasks include the selection of biocidal agent from among the variety used for surgical scrub, formulation of a dispensing system, test, and delivery of flight dispensers. The choice of an iodophore was based on effectiveness on single applications, general familiarity among surgeons, and previous qualification for space use. The delivery system was a choice between the squeeze foamer system and impregnated polyurethane foam pads. The impregnated foam pad was recommended because it is a simpler system since the squeeze foamer requires some applicator to effectively clean the skin surfaces, whereas the form pad is the applicator and agent combined. Testing demonstrated that both systems are effective for use as surgical scrubs.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lott, D F

    These tests evaluated flow-driven brushes, recirculating sponge rubber balls, chlorination, and mechanical system/chlorination combinations for in-situ cleaning of two potential heat exchanger materials: titanium and aluminum alloy 5052. Tests were successful when fouling resistance was <3.0 x 10/sup -4/ ft/sup 2/ hr-/sup 0/F/Btu. Results indicated systems and cleaning techniques using brushes, soft sponge balls, and various concentrations of chlorine had some potential for maintaining heat transfer efficiency.

  13. Cleaning Process Development for Metallic Additively Manufactured Parts

    NASA Technical Reports Server (NTRS)

    Tramel, Terri L.; Welker, Roger; Lowery, Niki; Mitchell, Mark

    2014-01-01

    Additive Manufacturing of metallic components for aerospace applications offers many advantages over traditional manufacturing techniques. As a new technology, many aspects of its widespread utilization remain open to investigation. Among these are the cleaning processes that can be used for post finishing of parts and measurements to verify effectiveness of the cleaning processes. Many cleaning and drying processes and measurement methods that have been used for parts manufactured using conventional techniques are candidates that may be considered for cleaning and verification of additively manufactured parts. Among these are vapor degreasing, ultrasonic immersion and spray cleaning, followed by hot air drying, vacuum baking and solvent displacement drying. Differences in porosity, density, and surface finish of additively manufactured versus conventionally manufactured parts may introduce new considerations in the selection of cleaning and drying processes or the method used to verify their effectiveness. This presentation will review the relative strengths and weaknesses of different candidate cleaning and drying processes as they may apply to additively manufactured metal parts for aerospace applications. An ultrasonic cleaning technique for exploring the cleanability of parts will be presented along with an example using additively manufactured Inconel 718 test specimens to illustrate its use. The data analysis shows that this ultrasonic cleaning approach results in a well-behaved ultrasonic cleaning/extraction behavior. That is, it does not show signs of accelerated cavitation erosion of the base material, which was later confirmed by neutron imaging. In addition, the analysis indicated that complete cleaning would be achieved by ultrasonic immersion cleaning at approximately 5 minutes, which was verified by subsequent cleaning of additional parts.

  14. Novel fracture technology proves marginal Viking prospect economic, part II: Well clean-up, flowback and testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haidar, S.; Rylance, M.; Tybero, G.

    1996-12-31

    Having completed both fracture treatments as discussed in a companion paper, this paper continues on to describe the post fracture shut-in, clean-up and well testing operations that took place on the Viking Wx exploration well 49/17-12. These operations involved the removal of Resin Coated Proppant (RCP) from the wellbore, via Coiled Tubing (CT), through the use of a specially designed jetting nozzle. The RCP pack stability at a concentration of 3.0 lb/ft{sup 2} (as per planned design) had already been tested in a flowback cell. The use of a Surface Read-Out (SRO) gauge, combined with gas, water and proppant flowmore » rates as well as the viscosity of fracturing fluids returns, enabled real time calculation of the drag forces, on the proppant pack, during clean-up. The flow rate, in the field, was controlled such that the calculated drag forces remained below those observed in the laboratory. Following the clean-up a flow and build-up test was conducted, to evaluate the fracture half length and fracture conductivity, from which a Pseudo-radial skin was calculated. The Non-Darcy effects in the fracture were also evaluated, and finally the short term and long term well deliverabilities were assessed.« less

  15. Laser versus scalpel cleaning of crustose lichens on granite

    NASA Astrophysics Data System (ADS)

    Rivas, T.; Pozo-Antonio, J. S.; López de Silanes, M. E.; Ramil, A.; López, A. J.

    2018-05-01

    This paper addresses the evaluation of the cleaning of crustose lichens developing on granite. The evaluation was performed considering the effectiveness of the cleanings and harmfulness exerted on the granite. The laser cleaning of lichen was compared with the most conventional procedure, scalpel. The combination of both procedures was also tested. The study, which was carried out with two different species of crustose lichen, was also focused on the influence of the intrinsic characteristics of the lichen on the effectiveness. The cleanings were evaluated by optic and electronic microscopies, FTIR and colour spectrophotometry. A previous characterization of the lichen and its interaction with the granite using those analytical techniques were also performed. The laser cleaning effectiveness depends on the coverage and the colour of the lichen; also, the prior mechanical weakening of the lichen by scalpel seemed to improve the laser cleaning. The darkest lichen was satisfactorily removed by laser and with the combined cleaning. Conversely, the lightest lichen was more difficult to extract with laser than the darkest lichen, being necessary to apply both methods sequentially. Despite laser and the combination of methods cleaned satisfactorily the surface, they were unable to eliminate the thalli into fissures.

  16. Dynamic self-cleaning in gecko setae via digital hyperextension

    PubMed Central

    Hu, Shihao; Lopez, Stephanie; Niewiarowski, Peter H.; Xia, Zhenhai

    2012-01-01

    Gecko toe pads show strong adhesion on various surfaces yet remain remarkably clean around everyday contaminants. An understanding of how geckos clean their toe pads while being in motion is essential for the elucidation of animal behaviours as well as the design of biomimetic devices with optimal performance. Here, we test the self-cleaning of geckos during locomotion. We provide, to our knowledge, the first evidence that geckos clean their feet through a unique dynamic self-cleaning mechanism via digital hyperextension. When walking naturally with hyperextension, geckos shed dirt from their toes twice as fast as they would if walking without hyperextension, returning their feet to nearly 80 per cent of their original stickiness in only four steps. Our dynamic model predicts that when setae suddenly release from the attached substrate, they generate enough inertial force to dislodge dirt particles from the attached spatulae. The predicted cleaning force on dirt particles significantly increases when the dynamic effect is included. The extraordinary design of gecko toe pads perfectly combines dynamic self-cleaning with repeated attachment/detachment, making gecko feet sticky yet clean. This work thus provides a new mechanism to be considered for biomimetic design of highly reuseable and reliable dry adhesives and devices. PMID:22696482

  17. Influence of Using Clinical Microscope as Auxiliary to Perform Mechanical Cleaning of Post Space: A Bond Strength Analysis.

    PubMed

    Ferreira, Ricardo; Prado, Maíra; de Jesus Soares, Adriana; Zaia, Alexandre Augusto; de Souza-Filho, Francisco José

    2015-08-01

    The aim of the present study was to evaluate the influence of using a clinical microscope while performing mechanical cleaning of post space walls on the bond strength of a fiberglass post to dentin. Forty-five bovine roots were used. After preparation, roots were filled using gutta-percha and Pulp Canal Sealer (SybronEndo, Orange, CA). Subsequently, for post space preparation, the roots were divided into 3 groups: control (only heat condenser + specific bur of the post system); cleaning without a microscope, mechanical cleaning (after the procedure described in the control group, round burs were used to improve cleaning); and cleaning with a microscope, mechanical cleaning performed with round burs visualized under a clinical microscope. Then, fiberglass posts were cemented. The roots were prepared and evaluated by the push-out test. Data were analyzed using Kruskal-Wallis and Student-Newman-Keuls tests (P < .05). The failure pattern was classified as follows: adhesive between the cement and dentin, adhesive dentin/cement/post, mixed cohesive within dentin, mixed cohesive post, and mixed cohesive post/dentin. The bond strength values (mean ± standard deviation) were control (cervical 1.17 ± 1.1, middle 0.40 ± 0.3, apical 0.52 ± 0.3, and total 0.95 ± 1.9), cleaning without a microscope (cervical 1.66 ± 2.3, middle 0.65 ± 1.1, apical 0.79 ± 1.2, and total1.04 ± 1.7), and cleaning with a microscope (cervical 3.26 ± 2.8, middle 1.97 ± 3.5, apical 1.85 ± 4.1, and total 2.37 ± 3.5). In the cleaning with a microscope group, the bond strength values were significantly higher than those in the other groups. In all groups, the main failure pattern was adhesive between cement and dentin. The use of a clinical microscope while performing mechanical cleaning during post space preparation improved the bond strength of a fiberglass post to dentin. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Surgical site infections among high-risk patients in clean-contaminated head and neck reconstructive surgery: concordance with preoperative oral flora.

    PubMed

    Yang, Ching-Hsiang; Chew, Khong-Yik; Solomkin, Joseph S; Lin, Pao-Yuan; Chiang, Yuan-Cheng; Kuo, Yur-Ren

    2013-12-01

    Salivary contamination of surgical wounds in clean-contaminated head and neck surgery with free flap reconstruction remains a major cause of infection and leads to significant morbidity. This study investigates the correlation between intraoral flora and surgical site infections (SSIs) among high-risk head and neck cancer patients undergoing resection and free flap reconstruction. One hundred twenty-nine patients were identified as being at high risk for infective complications based on cancer stage, tumor size, comorbid factors, and extent of reconstruction. All patients had intraoral swab cultures before surgery. Patients with culture-confirmed SSI after surgery were chosen for analysis, using the κ index and its 95% confidence interval for concordance analysis. All patients received clindamycin and gentamicin for antibiotic prophylaxis for 5 days. Antibiotic susceptibility testing of all isolates was obtained and analyzed. Thirty-seven patients experienced SSI, or an infection rate of 28.3%, occurring at a mean of 9.3 postoperative days. The overall concordance between oral flora and SSI was fair to moderate (κ index of 0.25), but detailed analysis shows a higher concordance for known and opportunistic pathogens, such as Pseudomonas aeruginosa and Enterococcus faecalis, compared to typical oral commensals. Antibiotic susceptibility tests show rapid and significant increases in resistance to clindamycin, indicating a need for a more effective alternative. Predicting pathogens in SSI using preoperative oral swabs did not demonstrate a good concordance in general for patients undergoing clean-contaminated head and neck surgery, although concordance for certain pathogenic species seem to be higher than for typical intraoral commensals. The rapid development of resistance to clindamycin precludes its use as a prophylactic agent.

  19. Determination of the Basic Friction Angle of Rock Surfaces by Tilt Tests

    NASA Astrophysics Data System (ADS)

    Jang, Hyun-Sic; Zhang, Qing-Zhao; Kang, Seong-Seung; Jang, Bo-An

    2018-04-01

    Samples of Hwangdeung granite from Korea and Berea sandstone from USA, both containing sliding planes, were prepared by saw-cutting or polishing using either #100 or #600 grinding powders. Their basic friction angles were measured by direct shear testing, triaxial compression testing, and tilt testing. The direct shear tests and triaxial compression tests on the saw-cut, #100, and #600 surfaces indicated that the most reliable results were obtained from the #100 surface: basic friction angle of 29.4° for granite and 34.1° for sandstone. To examine the effect of surface conditions on the friction angle in tilt tests, the sliding angles were measured 50 times with two surface conditions (surfaces cleaned and not cleaned after each measurement). The initial sliding angles were high regardless of rock type and surface conditions and decreased exponentially as measurements continued. The characteristics of the sliding angles, differences between tilt tests, and dispersion between measurements in each test indicated that #100 surface produced the most reliable basic friction angle measurement. Without cleaning the surfaces, the average angles for granite (32 measurements) and sandstone (23 measurements) were similar to the basic friction angle. When 20-50 measurements without cleaning were averaged, the basic friction angle was within ± 2° for granite and ± 3° for sandstone. Sliding angles using five different tilting speeds were measured but the average was similar, indicating that tilting speed (between 0.2° and 1.6°/s) has little effect on the sliding angle. Sliding angles using four different sample sizes were measured with the best results obtained for samples larger than 8 × 8 cm.

  20. Tampa's Well-being: A Demonstration of ORD's Human Well-being Index (web content for the Tampa Bay Ecosystem services website)

    EPA Science Inventory

    Ecosystems provide services to humans that support our well-being. Well-being is not only our health but also our quality of life. We rely upon the services provided by nature to help maintain good health and a high quality of life, including clean water, clean air, food and recr...

  1. Testing animal-assisted cleaning prior to transplantation in coral reef restoration.

    PubMed

    Frias-Torres, Sarah; van de Geer, Casper

    2015-01-01

    Rearing coral fragments in nurseries and subsequent transplantation onto a degraded reef is a common approach for coral reef restoration. However, if barnacles and other biofouling organisms are not removed prior to transplantation, fish will dislodge newly cemented corals when feeding on biofouling organisms. This behavior can lead to an increase in diver time due to the need to reattach the corals. Thus, cleaning nurseries to remove biofouling organisms such as algae and invertebrates is necessary prior to transplantation, and this cleaning constitutes a significant time investment in a restoration project. We tested a novel biomimicry technique of animal-assisted cleaning on nursery corals prior to transplantation at a coral reef restoration site in Seychelles, Indian Ocean. To determine whether animal-assisted cleaning was possible, preliminary visual underwater surveys were performed to quantify the fish community at the study site. Then, cleaning stations consisting of nursery ropes carrying corals and biofouling organisms, set at 0.3 m, 2 m, 4 m, 6 m and 8 m from the seabed, were placed at both the transplantation (treatment) site and the nursery (control) site. Remote GoPro video cameras recorded fish feeding at the nursery ropes without human disturbance. A reef fish assemblage of 32 species from 4 trophic levels (18.8% herbivores, 18.8% omnivores, 59.3% secondary consumers and 3.1% carnivores) consumed 95% of the barnacles on the coral nursery ropes placed 0.3 m above the seabed. Using this cleaning station, we reduced coral dislodgement from 16% to zero. This cleaning station technique could be included as a step prior to coral transplantation worldwide on the basis of location-specific fish assemblages and during the early nursery phase of sexually produced juvenile corals.

  2. Testing animal-assisted cleaning prior to transplantation in coral reef restoration

    PubMed Central

    van de Geer, Casper

    2015-01-01

    Rearing coral fragments in nurseries and subsequent transplantation onto a degraded reef is a common approach for coral reef restoration. However, if barnacles and other biofouling organisms are not removed prior to transplantation, fish will dislodge newly cemented corals when feeding on biofouling organisms. This behavior can lead to an increase in diver time due to the need to reattach the corals. Thus, cleaning nurseries to remove biofouling organisms such as algae and invertebrates is necessary prior to transplantation, and this cleaning constitutes a significant time investment in a restoration project. We tested a novel biomimicry technique of animal-assisted cleaning on nursery corals prior to transplantation at a coral reef restoration site in Seychelles, Indian Ocean. To determine whether animal-assisted cleaning was possible, preliminary visual underwater surveys were performed to quantify the fish community at the study site. Then, cleaning stations consisting of nursery ropes carrying corals and biofouling organisms, set at 0.3 m, 2 m, 4 m, 6 m and 8 m from the seabed, were placed at both the transplantation (treatment) site and the nursery (control) site. Remote GoPro video cameras recorded fish feeding at the nursery ropes without human disturbance. A reef fish assemblage of 32 species from 4 trophic levels (18.8% herbivores, 18.8% omnivores, 59.3% secondary consumers and 3.1% carnivores) consumed 95% of the barnacles on the coral nursery ropes placed 0.3 m above the seabed. Using this cleaning station, we reduced coral dislodgement from 16% to zero. This cleaning station technique could be included as a step prior to coral transplantation worldwide on the basis of location-specific fish assemblages and during the early nursery phase of sexually produced juvenile corals. PMID:26468440

  3. Quantity and quality benefits of in-service invasive cleaning of trunk mains

    NASA Astrophysics Data System (ADS)

    Sunny, Iftekhar; Husband, Stewart; Drake, Nick; Mckenzie, Kevan; Boxall, Joby

    2017-07-01

    Trunk mains are high risk critical infrastructure where poor performance can impact on large numbers of customers. Both quantity (e.g. hydraulic capacity) and quality (e.g. discolouration) of trunk main performance are affected by asset deterioration in the form of particle accumulation at the pipe wall. Trunk main cleaning techniques are therefore desirable to remove such material. However, little is quantified regarding the efficacy of different maintenance interventions or longer-term changes following such cleaning. This paper presents an assessment of quantity and quality performance of a trunk main system pre, post and for 12 months following cleaning using pigging with ice slurry. Hydraulic calibration showed a 7 times roughness height reduction after ice slurry pigging, evidencing substantially improved hydraulic capacity and reduced headloss. Turbidity response due to carefully imposed shear stress increase remained significant after the cleaning intervention, showing that relatively loose material had not been fully removed from the pipe wall. Overall the results demonstrate that cleaning by pigging with ice slurry can be beneficial for quantity performance, but care and further assessment may be necessary to realise the full quality benefits.

  4. Bioinspired Multifunctional Paper-Based rGO Composites for Solar-Driven Clean Water Generation.

    PubMed

    Lou, Jinwei; Liu, Yang; Wang, Zhongyong; Zhao, Dengwu; Song, Chengyi; Wu, Jianbo; Dasgupta, Neil; Zhang, Wang; Zhang, Di; Tao, Peng; Shang, Wen; Deng, Tao

    2016-06-15

    Reusing polluted water through various decontamination techniques has appeared as one of the most practical approaches to address the global shortage of clean water. Rather than relying on single decontamination mechanism, herein we report the preparation and utilization of paper-based composites for multifunctional solar-driven clean water generation that is inspired by the multiple water purification approaches in biological systems. The reduced graphene oxide (rGO) sheets within such composites can efficiently remove organic contaminants through physical adsorption mechanism. Under solar irradiation, the floating rGO composites can instantly generate localized heating, which not only can directly generate clean water through distillation mechanism but also significantly enhance adsorption removal performance with the assistance of upward vapor flow. Such porous-structured paper-based composites allow for facile incorporation of photocatalysts to regenerate clean water out of contaminated water with combined adsorption, photodegradation, and interfacial heat-assisted distillation mechanisms. Within a homemade all-in-one water treatment device, the practical applicability of the composites for multifunctional clean water generation has been demonstrated.

  5. Non-Volatile Residue (NVR) Contamination from Dry Handling and Solvent Cleaning

    NASA Technical Reports Server (NTRS)

    Sovinski, Marjorie F.

    2009-01-01

    This slide presentation reviews the testing for Non-Volatile Residue contamination transferred to surfaces from handling and solvent cleaning. Included in the presentation is a list of the items tested, formal work instructions dealing with NVR. There is an explanation of the Gravimetric determination method used to test the NVR in a variety of items, i.e., Gloves, Swabs, Garments, Bagging material, film and Wipes. Another method to test for contamination from NVR is the contact transfer method. The use of this method for testing gloves, garments, bagging material and film is explained. Certain equations use in NVR analysis and the use of a database for testing of NVR in consumables are reviewed.

  6. Environmental Remediation Activities in Japan Following the Fukushima Dai-ichi Reactor Incident - 12603

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lively, J.W.; Kelley, J.L.; Marcial, M.R.

    2012-07-01

    In March 2011, the Fukushima Dai-ichi reactor power plant was crippled by the Great Pacific earthquake and subsequent tsunami. Much of the focus in the news was on the reactor site itself as the utility company (TEPCO), the Japanese government, and experts from around the world worked to bring the damaged plants into a safe shutdown condition and stem the release of radioactivity to the environment. Most of the radioactivity released was carried out to sea with the prevailing winds. Still, as weather patterns changed and winds shifted, a significant plume of radioactive materials released from the plant deposited inmore » the environment surrounding the plant, contaminating large land areas of the Fukushima Prefecture. The magnitude of the radiological impact to the surrounding environmental is so large that the Japanese government has had to reevaluate the meaning of 'acceptably clean'. In many respects, 'acceptably clean' cannot be a one-size-fits-all standard. The economics costs of such an approach would make impossible what is already an enormous and costly environmental response and remediation task. Thus, the Japanese government has embarked upon an approach that is both situation-specific and reasonably achievable. For example, the determination of acceptably clean for a nursery school or kindergarten play yard may be different from that for a parking lot. The acceptably clean level of residual radioactivity in the surface soil of a rice paddy is different from that in a forested area. The recognized exposure situation (scenario) thus plays a large role in the decision process. While sometimes complicated to grasp or implement, such an approach does prioritize national resources to address environment remediation based upon immediate and significant risks. In addition, the Japanese government is testing means and methods, including advanced or promising technologies, that could be proven to be effective in reducing the amount of radioactivity in the environment beyond a fixed, concentration based limit. Essentially, the definition of acceptably clean includes the concept of reasonably achievable, given the available technology, means and methods, and the cost to implement such. The Japanese government recently issued three technology demonstration contracts expressly designed to test and evaluate the available technologies, means, and methods, which, if implemented, might produce the greatest risk reduction from environmental contamination for the best value. One of the Japanese contract holders, Obayashi JV, has teamed with AMEC to demonstrate the applicability and capabilities of the Orion ScanPlot{sup SM} and ScanSort{sup SM} technologies in radiologically impacted towns both inside and immediately outside the 20 km restricted zone. This presentation provides some unique images and informative insight into the environmental radioactive impacts in and around the exclusion zone. It will provide a look at one element of the Japanese government?s efforts to achieve the greatest risk reduction that is reasonably achievable. The Orion ScanPlot{sup SM} and ScanSort{sup SM} are being used with success on the Japan Town Demonstration Project to assess pre-remedial action contamination levels, document the post-remedial action contamination levels and to precisely measure and segregate excavated soils based on their radioactive content and the prescribed segregation limits (DCS). Initial results suggest that these technologies could provide capabilities to the remedial action efforts that would result in considerable improvements in field data certainty and compliance with remedial objectives while reducing overall costs. (authors)« less

  7. Quiet Clean Short-haul Experimental Engine (QCSEE)

    NASA Technical Reports Server (NTRS)

    Willis, W. S.

    1979-01-01

    The design, fabrication, and testing of two experimental propulsion systems for powered lift transport aircraft are given. The under the wing (UTW) engine was intended for installation in an externally blown flap configuration and the over the wing (OTW) engine for use in an upper surface blowing aircraft. The UTW engine included variable pitch composite fan blades, main reduction gear, composite fan frame and nacelle, and a digital control system. The OTW engine included a fixed pitch fan, composite fan frame, boilerplate nacelle, and a full authority digital control. Many acoustic, pollution, performance, and weight goals were demonstrated.

  8. Demonstration of SCR technology for the control of NOx emissions from high-sulfur coal-fired utility boilers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinton, W.S.; Maxwell, J.D.; Healy, E.C.

    1997-12-31

    This paper describes the completed Innovative Clean Coal Technology project which demonstrated SCR technology for reduction of flue gas NO{sub x} emissions from a utility boiler burning US high-sulfur coal. The project was sponsored by the US Department of Energy, managed and co-funded by Southern Company Services, Inc. on behalf of the Southern Company, and also co-funded by the Electric Power Research Institute and Ontario Hydro. The project was located at Gulf Power Company`s Plant Crist Unit 5 (a 75 MW tangentially-fired boiler burning US coals that had a sulfur content ranging from 2.5--2.9%), near Pensacola, Florida. The test programmore » was conducted for approximately two years to evaluate catalyst deactivation and other SCR operational effects. The SCR test facility had nine reactors: three 2.5 MW (5,000 scfm), and operated on low-dust flue gas. The reactors operated in parallel with commercially available SCR catalysts obtained from suppliers throughout the world. Long-term performance testing began in July 1993 and was completed in July 1995. A brief test facility description and the results of the project are presented in this paper.« less

  9. Spacecraft Communications System Verification Using On-Axis Near Field Measurement Techniques

    NASA Technical Reports Server (NTRS)

    Keating, Thomas; Baugh, Mark; Gosselin, R. B.; Lecha, Maria C.; Krebs, Carolyn A. (Technical Monitor)

    2000-01-01

    Determination of the readiness of a spacecraft for launch is a critical requirement. The final assembly of all subsystems must be verified. Testing of a communications system can mostly be done using closed-circuits (cabling to/from test ports), but the final connections to the antenna require radiation tests. The Tropical Rainfall Measuring Mission (TRMM) Project used a readily available 'near-fleld on-axis' equation to predict the values to be used for comparison with those obtained in a test program. Tests were performed in a 'clean room' environment at both Goddard Space Flight Center (GSFC) and in Japan at the Tanegashima Space Center (TnSC) launch facilities. Most of the measured values agreed with the predicted values to within 0.5 dB. This demonstrates that sometimes you can use relatively simple techniques to make antenna performance measurements when use of the 'far field ranges, anechoic chambers, or precision near-field ranges' are neither available nor practical. Test data and photographs are provided.

  10. EVALUATION OF PERSONAL COOLING DEVICES FOR A DIOXIN CLEAN-UP OPERATION

    EPA Science Inventory

    The study investigated the use of personal coolers to increase worker productivity and safety while working at elevated, ambient temperatures cleaning up dioxin contaminated soil.^The study included laboratory tests to measure the thermal characteristics of the chemical protectiv...

  11. Application of VitaVallis dressing for infected wounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirilova, N. V., E-mail: n.kirilova@vitavallis.com; Fomenko, A. N., E-mail: alserova@ispms.tsc.ru; Korovin, M. S., E-mail: msk@ispms.tsc.ru

    Today there is a growing demand for safe and efficient antimicrobial dressings for infected wound treatment. The antimicrobial sorption material for VitaVallis dressings was produced by one-stage oxidation of aluminum nanopowder in water in the presence of fibrous acetylcellulose matrix. Scanning electron microscopy revealed that the material is made up of fibers of diameter 1.5–3.0 µm with adhered agglomerated alumina nanosheets. An antimicrobial study revealed a high inhibitory effect of VitaVallis against the growth of gram-negative (E.coli, P. aeruginosa) and gram-positive (S. aureus) strains. The antimicrobial activity of the dressing against microbial pathogens on the wound surface was demonstrated in inmore » vivo experiments on male rats. The dressing was also tested on volunteer patients. The testing showed reduction of the wound healing period, accelerated cleaning of the infected wound and enhanced tissue regeneration in the wound. The results demonstrate that the VitaVallis dressing can be used for the treatment of deep infected wounds.« less

  12. Current Space Station Experiments Investigating Component Level Electronics Repair

    NASA Technical Reports Server (NTRS)

    Easton, John W.; Struk, Peter M.

    2010-01-01

    The Soldering in a Reduced Gravity Experiment (SoRGE) and Component Repair Experiment (CRE)-1 are tests performed on the International Space Station to determine the techniques, tools, and training necessary to allow future crews to perform manual electronics repairs at the component level. SoRGE provides information on the formation and internal structure of through-hole solder joints, illustrating the challenges and implications of soldering in reduced gravity. SoRGE showed a significant increase in internal void defects for joints formed in low gravity compared to normal gravity. Methods for mitigating these void defects were evaluated using a modified soldering process. CRE-1 demonstrated the removal, cleaning, and replacement of electronics components by manual means on functional circuit boards. The majority of components successful passed a post-repair functional test demonstrating the feasibility of component-level repair within the confines of a spacecraft. Together, these tasks provide information to recommend material and tool improvements, training improvements, and future work to help enable electronics repairs in future space missions.

  13. Evaluation of Commercially-Available Equipment for the ...

    EPA Pesticide Factsheets

    Report The Underground Transport Restoration (UTR) project is an inter-agency effort. This effort aims to improve the capability for transit systems to quickly and efficiently recover from a biological contamination incident by refining existing methods, tools and protocols for characterization, clean-up, and clearance of contamination in physical structures (i.e., tunnels, stations) and rolling stock (i.e., subway trains). The aim was to evaluate existing sampling, characterization, and decontamination technologies through experimentation, table-top exercises and operational demonstrations to develop guidance and decision frameworks and support tools through interactions of local, state and federal partners. In this investigation, a survey of commercially-available or fielded equipment was conducted and resulted in three pieces of identified equipment that could be used or rapidly modified for use in dispensing liquid chemicals to decontaminate surfaces following a biological contamination incident. documenting lab-scale testing, field-scale testing, and an equipment demonstration of commercial equipment used to decontaminate subway infrastructure following a biological incident.

  14. Chemicals to help coal come clean

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thayer, A.M.

    Scrubbing methods to capture carbon from power plants are advancing to the demonstration phase. The article gives an update of projects around the world, and the goals and cost of CCS projects. BASF, together with RWE Power and Linde, are working to ensure state of the art integration of the carbon-capture process into a power plant to minimize the penalty in electrical output. A pilot project will test new solvents in an 'advanced amine' system at RWE's power station in Niederaussem, Germany. A pilot unit will soon capture CO{sub 2} from a coal-fired plant of Dow's in South Charleston, WV,more » USA and Dow has also agreed to build an amines demonstration facility in Belchatow, Poland. Other projects in the USA and Canada are reported. 1 fig.« less

  15. Efficiency of different protocols for enamel clean-up after bracket debonding: an in vitro study

    PubMed Central

    Sigilião, Lara Carvalho Freitas; Marquezan, Mariana; Elias, Carlos Nelson; Ruellas, Antônio Carlos; Sant'Anna, Eduardo Franzotti

    2015-01-01

    Objective: This study aimed to assess the efficiency of six protocols for cleaning-up tooth enamel after bracket debonding. Methods: A total of 60 premolars were divided into six groups, according to the tools used for clean-up: 12-blade bur at low speed (G12L), 12-blade bur at high speed (G12H), 30-blade bur at low speed (G30L), DU10CO ORTHO polisher (GDU), Renew System (GR) and Diagloss polisher (GD). Mean roughness (Ra) and mean roughness depth (Rz) of enamel surface were analyzed with a profilometer. Paired t-test was used to assess Ra and Rz before and after enamel clean-up. ANOVA/Tukey tests were used for intergroup comparison. The duration of removal procedures was recorded. The association between time and variation in enamel roughness (∆Ra, ∆Rz) were evaluated by Pearson's correlation test. Enamel topography was assessed by scanning electron microscopy (SEM). Results: In Groups G12L and G12H, original enamel roughness did not change significantly. In Groups G30L, GDU, GR and GD, a smoother surface (p < 0.05) was found after clean-up. In Groups G30L and GD, the protocols used were more time-consuming than those used in the other groups. Negative and moderate correlation was observed between time and (∆Ra, ∆Rz); Ra and (∆Ra, ∆Rz); Rz (r = - 0.445, r = - 0.475, p < 0.01). Conclusion: All enamel clean-up protocols were efficient because they did not result in increased surface roughness. The longer the time spent performing the protocol, the lower the surface roughness. PMID:26560825

  16. Influence of in-situ ion-beam sputter cleaning on the conditioning effect of vacuum gaps

    NASA Astrophysics Data System (ADS)

    Kobayashi, Shinichi; Kojima, Hiroyuki; Saito, Yoshio

    1994-05-01

    An ion beam sputtering technique was used to clean the electrode surfaces of vacuum gaps. Ions of the sputtering gas were irradiated by means of an ion gun in a vacuum chamber attached to a breakdown measurement chamber. By providing in situ ion-beam sputter cleaning, this system makes it possible to make measurements free from contamination due to exposure to the air. The sputtering gas was He or Ar, and the electrodes were made of oxygen-free copper (purity more than 99.96%). An impulse voltage with the wave form of 64/700 microsecond(s) was applied to the test gap, and the pressure in the breakdown measurement chamber at the beginning of breakdown tests was 1.3 X 10-8 Pa. These experiments showed that ion-beam sputter cleaning results in higher breakdown fields after a repetitive breakdown conditioning procedure, and that He is more effective in improving hold- off voltages after the conditioning (under the same ion current density, the breakdown field was 300 MV/m for He sputtering and 200 MV/m for Ar sputtering). The breakdown fields at the first voltage application after the sputtering cleaning, on the other hand, were not improved.

  17. New electrostatic coal cleaning method cuts sulfur content by 40%

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1985-12-01

    An emission control system that electrically charges pollutants and coal particles promises to reduce sulfur 40% at half the cost. The dry coal cleaning processes offer superior performance and better economics than conventional flotation cleaning. Advanced Energy Dynamics, Inc. (AED) is developing both fine and ultra fine processes which increase combustion efficiency and boiler reliability and reduced operating costs. The article gives details from the performance tests and comparisons and summarizes the economic analyses. 4 tables.

  18. Crude Oil Remote Sensing, Characterization and Cleaning with ContinuousWave and Pulsed Lasers

    DTIC Science & Technology

    2015-01-23

    explained by strong pressure spikes during cavitation in liquid jets . These experiments were not directly tested for the pipe cleaning, but their results...analytical functions (like circular, elliptical and similar shapes). In our case of cylindrical symmetry of the oil film shape is defined by two...the high-pressure (50 – 100 atm) oil and water jets (with cavitations in narrow tubes) revealed a new potential for a more efficient cleaning of

  19. Efficacy of commercially available wipes for disinfection of pulse oximeter sensors.

    PubMed

    Nandy, Poulomi; Lucas, Anne D; Gonzalez, Elizabeth A; Hitchins, Victoria M

    2016-03-01

    This study examined the effectiveness of commercially available disinfecting wipes and cosmetic wipes in disinfecting pulse oximeter sensors contaminated with pathogenic bacterial surrogates. Surrogates of potential biological warfare agents and bacterial pathogens associated with hospital-acquired infections (HAIs) were spotted on test surfaces, with and without an artificial test soil (sebum), allowed to dry, and then cleaned with different commercially available cleaning and disinfecting wipes or sterile gauze soaked in water, bleach (diluted 1:10), or 70% isopropanol. The percentage of microbial survival and an analytical estimation of remaining test soil on devices were determined. Wipes containing sodium hypochlorite as the active ingredient and gauze soaked in bleach (1:10) were the most effective in removing both vegetative bacteria and spores. In the presence of selective disinfectants, sebum had a protective effect on vegetative bacteria, but not on spores. The presence of sebum reduces the cleaning efficiency of some commercially available wipes for some select microbes. Various commercial wipes performed significantly better than the designated cleaning agent (70% isopropanol) in disinfecting the oximetry sensor. Cosmetic wipes were not more effective than the disinfecting wipes in removing sebum. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.

  20. Proof of concept demonstration of novel technologies for lunar spacesuit dust mitigation

    NASA Astrophysics Data System (ADS)

    Manyapu, Kavya K.; De Leon, Pablo; Peltz, Leora; Gaier, James R.; Waters, Deborah

    2017-08-01

    A recent report by NASA identified dust/particulate mitigation techniques as a highly relevant study for future long-term planetary exploration missions (NASA, 2015). The deleterious effects of lunar dust on spacesuits discovered during the Apollo missions has compelled NASA to identify dust mitigation as a critical path for potential future lunar, asteroid and Mars missions. The complexity of spacesuit design has however constrained integrating existing dust cleaning technologies, formerly demonstrated on rigid surfaces, into the spacesuit system. Accordingly, this research is investigating novel methods to integrate dust mitigation technologies for use on spacesuits. We examine utilizing a novel combination of active and passive technologies integrated into the spacesuit outerlayer to alleviate dust contamination. Leveraging two specific technologies, the Electrodynamics Dust Shield (EDS) active technology and Work Function Matching Coating (WFM) passive technology, developed by NASA for rigid surfaces, we apply new high performance materials such as the Carbon Nanotube (CNT) flexible fibers to develop a spacesuit-integrated dust cleaning system. Through experiments conducted using JSC-1A lunar dust simulant on coupons made of spacesuit outerlayer material, feasibility of integrating the proposed dust cleaning system and its performance were assessed. Results from these preliminary experiments show that the integrated dust cleaning system is capable of removing 80-95% of dust from the spacesuit material demonstrating proof of concept. This paper describes the techniques and results from the experiments. Future challenges of implementing the proposed approach into fight suits are identified.

  1. Significant OH production under surface cleaning and air cleaning conditions: Impact on indoor air quality.

    PubMed

    Carslaw, N; Fletcher, L; Heard, D; Ingham, T; Walker, H

    2017-11-01

    We report measurements of hydroxyl (OH) and hydroperoxy (HO 2 ) radicals made by laser-induced fluorescence spectroscopy in a computer classroom (i) in the absence of indoor activities (ii) during desk cleaning with a limonene-containing cleaner (iii) during operation of a commercially available "air cleaning" device. In the unmanipulated environment, the one-minute averaged OH concentration remained close to or below the limit of detection (6.5×10 5  molecule cm -3 ), whilst that of HO 2 was 1.3×10 7  molecule cm -3 . These concentrations increased to ~4×10 6 and 4×10 8  molecule cm -3 , respectively during desk cleaning. During operation of the air cleaning device, OH and HO 2 concentrations reached ~2×10 7 and ~6×10 8  molecule cm -3 respectively. The potential of these OH concentrations to initiate chemical processing is explored using a detailed chemical model for indoor air (the INDCM). The model can reproduce the measured OH and HO 2 concentrations to within 50% and often within a few % and demonstrates that the resulting secondary chemistry varies with the cleaning activity. Whilst terpene reaction products dominate the product composition following surface cleaning, those from aromatics and other VOCs are much more important during the use of the air cleaning device. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Staying sticky: contact self-cleaning of gecko-inspired adhesives.

    PubMed

    Mengüç, Yigit; Röhrig, Michael; Abusomwan, Uyiosa; Hölscher, Hendrik; Sitti, Metin

    2014-05-06

    The exceptionally adhesive foot of the gecko remains clean in dirty environments by shedding contaminants with each step. Synthetic gecko-inspired adhesives have achieved similar attachment strengths to the gecko on smooth surfaces, but the process of contact self-cleaning has yet to be effectively demonstrated. Here, we present the first gecko-inspired adhesive that has matched both the attachment strength and the contact self-cleaning performance of the gecko's foot on a smooth surface. Contact self-cleaning experiments were performed with three different sizes of mushroom-shaped elastomer microfibres and five different sizes of spherical silica contaminants. Using a load-drag-unload dry contact cleaning process similar to the loads acting on the gecko foot during locomotion, our fully contaminated synthetic gecko adhesives could recover lost adhesion at a rate comparable to that of the gecko. We observed that the relative size of contaminants to the characteristic size of the microfibres in the synthetic adhesive strongly determined how and to what degree the adhesive recovered from contamination. Our approximate model and experimental results show that the dominant mechanism of contact self-cleaning is particle rolling during the drag process. Embedding of particles between adjacent fibres was observed for particles with diameter smaller than the fibre tips, and further studied as a temporary cleaning mechanism. By incorporating contact self-cleaning capabilities, real-world applications of synthetic gecko adhesives, such as reusable tapes, clothing closures and medical adhesives, would become feasible.

  3. Staying sticky: contact self-cleaning of gecko-inspired adhesives

    PubMed Central

    Mengüç, Yiğit; Röhrig, Michael; Abusomwan, Uyiosa; Hölscher, Hendrik; Sitti, Metin

    2014-01-01

    The exceptionally adhesive foot of the gecko remains clean in dirty environments by shedding contaminants with each step. Synthetic gecko-inspired adhesives have achieved similar attachment strengths to the gecko on smooth surfaces, but the process of contact self-cleaning has yet to be effectively demonstrated. Here, we present the first gecko-inspired adhesive that has matched both the attachment strength and the contact self-cleaning performance of the gecko's foot on a smooth surface. Contact self-cleaning experiments were performed with three different sizes of mushroom-shaped elastomer microfibres and five different sizes of spherical silica contaminants. Using a load–drag–unload dry contact cleaning process similar to the loads acting on the gecko foot during locomotion, our fully contaminated synthetic gecko adhesives could recover lost adhesion at a rate comparable to that of the gecko. We observed that the relative size of contaminants to the characteristic size of the microfibres in the synthetic adhesive strongly determined how and to what degree the adhesive recovered from contamination. Our approximate model and experimental results show that the dominant mechanism of contact self-cleaning is particle rolling during the drag process. Embedding of particles between adjacent fibres was observed for particles with diameter smaller than the fibre tips, and further studied as a temporary cleaning mechanism. By incorporating contact self-cleaning capabilities, real-world applications of synthetic gecko adhesives, such as reusable tapes, clothing closures and medical adhesives, would become feasible. PMID:24554579

  4. Multi-class analysis of new psychoactive substances and metabolites in hair by pressurized liquid extraction coupled to HPLC-HRMS.

    PubMed

    Montesano, Camilla; Vannutelli, Gabriele; Massa, Maristella; Simeoni, Maria Chiara; Gregori, Adolfo; Ripani, Luigi; Compagnone, Dario; Curini, Roberta; Sergi, Manuel

    2017-05-01

    In this paper, an analytical method has been developed and validated for the analysis of new psychoactive substances (NPS) and metabolites in hair samples. The method was based on pressurized liquid extraction (PLE) followed by solid-phase extraction (SPE) clean-up and high performance liquid chromatography-high resolution mass spectrometry (HPLC-HRMS) analysis. To evaluate extraction efficiency and the applicability of the method, hair samples were fortified by soaking in order to obtain a good surrogate for drug users' hair; the amount of incorporated drugs related to their lipophilicity, similarly to in vivo drug incorporation. To the best of our knowledge, this is the first method that allowed for the analysis of both cathinones (5) and synthetic cannabinoids (7) in hair with a single extraction procedure and chromatographic run. A phenethylamine (2C-T-4), 4- fluorophenylpiperazine and methoxetamine were also included showing that PLE coupled to SPE clean-up was suitable for a multi-class analysis of NPS in hair. In addition, the use of PLE significantly reduced hair analysis time: decontamination, incubation, clean-up, and liquid chromatography-mass spectrometry (LC-MS) analysis were carried out in approximately 45 min. The method was fully validated according to Scientific Working Group for Forensic Toxicology (SWGTOX) and Society of Hair Testing (SoHT) guidelines. Limit of quantification (LOQ) values ranged from 8 to 50 pg mg -1 for cathinones, phenetylamines and piperazines, and from 9 to 40 pg mg -1 for synthetic cannabinoids (10 pg mg -1 for methoxetamine). Matrix effects were below 15% for all the analytes, demonstrating the effectiveness of the clean-up step. Inaccuracy was lower than 9% in terms of bias. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Optimisation and performance of NaClO-assisted maintenance cleaning for fouling control in membrane bioreactors.

    PubMed

    Wang, Zhizhen; Meng, Fangang; He, Xiang; Zhou, Zhongbo; Huang, Li-Nan; Liang, Shuang

    2014-04-15

    Based on conventional chemical cleaning and physical backflush methods, a novel in situ chemical backflush method, i.e., chemically assisted maintenance cleaning with NaClO as the principal reagent, was developed for membrane fouling control in membrane bioreactors (MBRs). The results demonstrated that, compared with a control MBR with water backflush, the use of low NaClO loads had few adverse effects on nutrient removal; on the contrary, the exposure to NaClO enhanced the denitrification performance of the MBR as a result of the formation of sludge granules. Measurements of transmembrane pressure (TMP) showed that an NaClO backflush at 0.2 ppm could achieve effective membrane fouling control in MBRs. Ex situ backflush tests showed that an NaClO backflush enhanced the detachment of biopolymers from the fouled membranes compared with a water backflush. Comparative 16S rRNA sequencing showed differing bacterial community composition in the fouling layers of the two MBRs. Specifically, the NaClO backflush could suppress filament-caused membrane fouling (i.e., lowered the abundance of Thiothrix eikelboomii in the fouling layers). Both the water and NaClO backflush resulted in significant increases in the pure water permeability of the membranes as a result of the enlargement of membrane pores. The results of Fourier transform infrared spectrometry indicated that the frequent NaClO backflush did not change the functional groups of the active layer of the membranes significantly. This study could provide an alternative for the implementation of membrane cleaning in MBR plants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Cleaning verification: A five parameter study of a Total Organic Carbon method development and validation for the cleaning assessment of residual detergents in manufacturing equipment.

    PubMed

    Li, Xue; Ahmad, Imad A Haidar; Tam, James; Wang, Yan; Dao, Gina; Blasko, Andrei

    2018-02-05

    A Total Organic Carbon (TOC) based analytical method to quantitate trace residues of clean-in-place (CIP) detergents CIP100 ® and CIP200 ® on the surfaces of pharmaceutical manufacturing equipment was developed and validated. Five factors affecting the development and validation of the method were identified: diluent composition, diluent volume, extraction method, location for TOC sample preparation, and oxidant flow rate. Key experimental parameters were optimized to minimize contamination and to improve the sensitivity, recovery, and reliability of the method. The optimized concentration of the phosphoric acid in the swabbing solution was 0.05M, and the optimal volume of the sample solution was 30mL. The swab extraction method was 1min sonication. The use of a clean room, as compared to an isolated lab environment, was not required for method validation. The method was demonstrated to be linear with a correlation coefficient (R) of 0.9999. The average recoveries from stainless steel surfaces at multiple spike levels were >90%. The repeatability and intermediate precision results were ≤5% across the 2.2-6.6ppm range (50-150% of the target maximum carry over, MACO, limit). The method was also shown to be sensitive with a detection limit (DL) of 38ppb and a quantitation limit (QL) of 114ppb. The method validation demonstrated that the developed method is suitable for its intended use. The methodology developed in this study is generally applicable to the cleaning verification of any organic detergents used for the cleaning of pharmaceutical manufacturing equipment made of electropolished stainless steel material. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Integrated low emissions cleanup system for direct coal-fueled turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lippert, T.E.; Newby, R.A.; Alvin, M.A.

    1992-01-01

    The Westinghouse Electric Corporation, Science Technology Center (W-STC) is developing an Integrated Low Emissions Cleanup (ILEC) concept for high-temperature gas cleaning to meet environmental standards, as well as to economical gas turbine life. The ILEC concept simultaneously controls sulfur, particulate, and alkali contaminants in high-pressure fuel gases or combustion gases at temperatures up to 1850[degrees]F for advanced power generation systems (PFBC, APFBC, IGCC, DCF7). The objective of this program is to demonstrate, at a bench scale, the conceptual, technical feasibility of the REC concept. The ELEC development program has a 3 phase structure: Phase 1 - laboratory-scale testing; phase 2more » - bench-scale equipment; design and fabrication; and phase 3 - bench-scale testing. Phase 1 laboratory testing has been completed. In Phase 1, entrained sulfur and alkali sorbent kinetics were measured and evaluated, and commercial-scale performance was projected. Related cold flow model testing has shown that gas-particle contacting within the ceramic barrier filter vessel will provide a good reactor environment. The Phase 1 test results and the commercial evaluation conducted in the Phase 1 program support the bench-scale facility testing to be performed in Phase 3. Phase 2 is nearing completion with the design and assembly of a modified, bench-scale test facility to demonstrate the technical feasibility of the ILEC features. This feasibility testing will be conducted in Phase 3.« less

  8. Integrated low emissions cleanup system for direct coal-fueled turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lippert, T.E.; Newby, R.A.; Alvin, M.A.

    1992-12-31

    The Westinghouse Electric Corporation, Science & Technology Center (W-STC) is developing an Integrated Low Emissions Cleanup (ILEC) concept for high-temperature gas cleaning to meet environmental standards, as well as to economical gas turbine life. The ILEC concept simultaneously controls sulfur, particulate, and alkali contaminants in high-pressure fuel gases or combustion gases at temperatures up to 1850{degrees}F for advanced power generation systems (PFBC, APFBC, IGCC, DCF7). The objective of this program is to demonstrate, at a bench scale, the conceptual, technical feasibility of the REC concept. The ELEC development program has a 3 phase structure: Phase 1 - laboratory-scale testing; phasemore » 2 - bench-scale equipment; design and fabrication; and phase 3 - bench-scale testing. Phase 1 laboratory testing has been completed. In Phase 1, entrained sulfur and alkali sorbent kinetics were measured and evaluated, and commercial-scale performance was projected. Related cold flow model testing has shown that gas-particle contacting within the ceramic barrier filter vessel will provide a good reactor environment. The Phase 1 test results and the commercial evaluation conducted in the Phase 1 program support the bench-scale facility testing to be performed in Phase 3. Phase 2 is nearing completion with the design and assembly of a modified, bench-scale test facility to demonstrate the technical feasibility of the ILEC features. This feasibility testing will be conducted in Phase 3.« less

  9. Technology Catalogue. First edition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-02-01

    The Department of Energy`s Office of Environmental Restoration and Waste Management (EM) is responsible for remediating its contaminated sites and managing its waste inventory in a safe and efficient manner. EM`s Office of Technology Development (OTD) supports applied research and demonstration efforts to develop and transfer innovative, cost-effective technologies to its site clean-up and waste management programs within EM`s Office of Environmental Restoration and Office of Waste Management. The purpose of the Technology Catalogue is to provide performance data on OTD-developed technologies to scientists and engineers assessing and recommending technical solutions within the Department`s clean-up and waste management programs, asmore » well as to industry, other federal and state agencies, and the academic community. OTD`s applied research and demonstration activities are conducted in programs referred to as Integrated Demonstrations (IDs) and Integrated Programs (IPs). The IDs test and evaluate.systems, consisting of coupled technologies, at specific sites to address generic problems, such as the sensing, treatment, and disposal of buried waste containers. The IPs support applied research activities in specific applications areas, such as in situ remediation, efficient separations processes, and site characterization. The Technology Catalogue is a means for communicating the status. of the development of these innovative technologies. The FY93 Technology Catalogue features technologies successfully demonstrated in the field through IDs and sufficiently mature to be used in the near-term. Technologies from the following IDs are featured in the FY93 Technology Catalogue: Buried Waste ID (Idaho National Engineering Laboratory, Idaho); Mixed Waste Landfill ID (Sandia National Laboratories, New Mexico); Underground Storage Tank ID (Hanford, Washington); Volatile organic compound (VOC) Arid ID (Richland, Washington); and VOC Non-Arid ID (Savannah River Site, South Carolina).« less

  10. Experimental clean combustor program, phase 2

    NASA Technical Reports Server (NTRS)

    Gleason, C. C.; Rogers, D. W.; Bahr, D. W.

    1976-01-01

    The primary objectives of this three-phase program are to develop technology for the design of advanced combustors with significantly lower pollutant emission levels than those of current combustors, and to demonstrate these pollutant emission reductions in CF6-50C engine tests. The purpose of the Phase 2 Program was to further develop the two most promising concepts identified in the Phase 1 Program, the double annular combustor and the radial/axial staged combustor, and to design a combustor and breadboard fuel splitter control for CF6-50 engine demonstration testing in the Phase 3 Program. Noise measurement and alternate fuels addendums to the basic program were conducted to obtain additional experimental data. Twenty-one full annular and fifty-two sector combustor configurations were evaluated. Both combustor types demonstrated the capability for significantly reducing pollutant emission levels. The most promising results were obtained with the double annular combustor. Rig test results corrected to CF-50C engine conditions produced EPA emission parameters for CO, HC, and NOX of 3.4, 0.4, and 4.5 respectively. These levels represent CO, HC, and NOX reductions of 69, 90, and 42 percent respectively from current combustor emission levels. The combustor also met smoke emission level requirements and development engine performance and installation requirements.

  11. Cleanroom Garment Silicone Contamination

    NASA Technical Reports Server (NTRS)

    Geer, Wayne; Lepage, Colette

    2006-01-01

    The slide presentation reviews actions taken at Goddard Space Flight Center (GSFC) to eliminate contamination by silicone in clean rooms. Background information includes facilities and hardware affected by silicon contamination, a discussion of the negative aspects of silicone contamination, clean room garments, and how the problem was identified at GSFC. Actions taken by the GSFC Contamination Engineering Group and lessons learned are detailed. Results include: awareness of the silicone issue in laundry, increase in infrastructure and support of the testing lab, establishment of protocols for garment verification, closer relationship established with laundry and converter, specifications for laundry services and garments were strengthened, all consumables are tested before use in clean rooms, and established procedures were used to identify and treat silicone found on face masks.

  12. Evidence for self-cleaning in gecko setae

    NASA Astrophysics Data System (ADS)

    Hansen, W. R.; Autumn, K.

    2005-01-01

    A tokay gecko can cling to virtually any surface and support its body mass with a single toe by using the millions of keratinous setae on its toe pads. Each seta branches into hundreds of 200-nm spatulae that make intimate contact with a variety of surface profiles. We showed previously that the combined surface area of billions of spatulae maximizes van der Waals interactions to generate large adhesive and shear forces. Geckos are not known to groom their feet yet retain their stickiness for months between molts. How geckos manage to keep their feet clean while walking about with sticky toes has remained a puzzle until now. Although self-cleaning by water droplets occurs in plant and animal surfaces, no adhesive has been shown to self-clean. In the present study, we demonstrate that gecko setae are a self-cleaning adhesive. Geckos with dirty feet recovered their ability to cling to vertical surfaces after only a few steps. Self-cleaning occurred in arrays of setae isolated from the gecko. Contact mechanical models suggest that self-cleaning occurs by an energetic disequilibrium between the adhesive forces attracting a dirt particle to the substrate and those attracting the same particle to one or more spatulae. We propose that the property of self-cleaning is intrinsic to the setal nanostructure and therefore should be replicable in synthetic adhesive materials in the future. adhesion | contact mechanics | locomotion | reptilia | nanotechnology

  13. Fusion Welding Research.

    DTIC Science & Technology

    1983-04-30

    contaminants from the surface. Further studies of this effect of oxygen on cathodic cleaning of aluminum are being held pending further results of GMAW of...oxygen on cathodic cleaning of aluminum has resulted from these tests, but much more information on the fundamentals of metal transfer in pulsed GMAW

  14. The Clean Air Act Amendments of 1990: Hazardous Air Pollutant Requirements and the DOE Clean Coal Technology Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moskowitz, P.D.; DePhillips, M.; Fthenakis, V.M.

    1991-12-31

    The purpose of the US Department of Energy -- Office of Fossil Energy (DOE FE) Clean Coal Technology Program (CCTP) is to provide the US energy marketplace with advanced, efficient, and environmentally sound coal-based technologies. The design, construction, and operation of Clean Coal Technology Demonstration Projects (CCTDP) will generate data needed to make informed, confident decisions on the commercial readiness of these technologies. These data also will provide information needed to ensure a proactive response by DOE and its industrial partners to the establishment of new regulations or a reactive response to existing regulations promulgated by the US Environmental Protectionmore » Agency (EPA). The objectives of this paper are to: (1) Present a preliminary examination of the potential implications of the Clean Air Act Amendments (CAAA) -- Title 3 Hazardous Air Pollutant requirements to the commercialization of CCTDP; and (2) help define options available to DOE and its industrial partners to respond to this newly enacted Legislation.« less

  15. The Clean Air Act Amendments of 1990: Hazardous Air Pollutant Requirements and the DOE Clean Coal Technology Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moskowitz, P.D.; DePhillips, M.; Fthenakis, V.M.

    1991-01-01

    The purpose of the US Department of Energy -- Office of Fossil Energy (DOE FE) Clean Coal Technology Program (CCTP) is to provide the US energy marketplace with advanced, efficient, and environmentally sound coal-based technologies. The design, construction, and operation of Clean Coal Technology Demonstration Projects (CCTDP) will generate data needed to make informed, confident decisions on the commercial readiness of these technologies. These data also will provide information needed to ensure a proactive response by DOE and its industrial partners to the establishment of new regulations or a reactive response to existing regulations promulgated by the US Environmental Protectionmore » Agency (EPA). The objectives of this paper are to: (1) Present a preliminary examination of the potential implications of the Clean Air Act Amendments (CAAA) -- Title 3 Hazardous Air Pollutant requirements to the commercialization of CCTDP; and (2) help define options available to DOE and its industrial partners to respond to this newly enacted Legislation.« less

  16. Continuous Droplet Removal upon Dropwise Condensation of Humid Air on a Hydrophobic Micropatterned Surface

    PubMed Central

    2015-01-01

    Combination of two physical phenomena, capillary pressure gradient and wettability gradient, allows a simple two-step fabrication process that yields a reliable hydrophobic self-cleaning condenser surface. The surface is fabricated with specific microscopic topography and further treatment with a chemically inert low-surface-energy material. This process does not require growth of nanofeatures (nanotubes) or hydrophilic–hydrophobic patterning of the surface. Trapezoidal geometry of the microfeatures facilitates droplet transfer from the Wenzel to the Cassie state and reduces droplet critical diameter. The geometry of the micropatterns enhances local coalescence and directional movement for droplets with diameter much smaller than the radial length of the micropatterns. The hydrophobic self-cleaning micropatterned condenser surface prevents liquid film formation and promotes continuous dropwise condensation cycle. Upon dropwise condensation, droplets follow a designed wettability gradient created with micropatterns from the most hydrophobic to the least hydrophobic end of the surface. The surface has higher condensation efficiency, due to its directional self-cleaning property, than a plain hydrophobic surface. We explain the self-actuated droplet collection mechanism on the condenser surface and demonstrate experimentally the creation of an effective wettability gradient over a 6 mm radial distance. In spite of its fabrication simplicity, the fabricated surface demonstrates self-cleaning property, enhanced condensation performance, and reliability over time. Our work enables creation of a hydrophobic condenser surface with the directional self-cleaning property that can be used for collection of biological (chemical, environmental) aerosol samples or for condensation enhancement. PMID:25073014

  17. Continuous droplet removal upon dropwise condensation of humid air on a hydrophobic micropatterned surface.

    PubMed

    Zamuruyev, Konstantin O; Bardaweel, Hamzeh K; Carron, Christopher J; Kenyon, Nicholas J; Brand, Oliver; Delplanque, Jean-Pierre; Davis, Cristina E

    2014-08-26

    Combination of two physical phenomena, capillary pressure gradient and wettability gradient, allows a simple two-step fabrication process that yields a reliable hydrophobic self-cleaning condenser surface. The surface is fabricated with specific microscopic topography and further treatment with a chemically inert low-surface-energy material. This process does not require growth of nanofeatures (nanotubes) or hydrophilic-hydrophobic patterning of the surface. Trapezoidal geometry of the microfeatures facilitates droplet transfer from the Wenzel to the Cassie state and reduces droplet critical diameter. The geometry of the micropatterns enhances local coalescence and directional movement for droplets with diameter much smaller than the radial length of the micropatterns. The hydrophobic self-cleaning micropatterned condenser surface prevents liquid film formation and promotes continuous dropwise condensation cycle. Upon dropwise condensation, droplets follow a designed wettability gradient created with micropatterns from the most hydrophobic to the least hydrophobic end of the surface. The surface has higher condensation efficiency, due to its directional self-cleaning property, than a plain hydrophobic surface. We explain the self-actuated droplet collection mechanism on the condenser surface and demonstrate experimentally the creation of an effective wettability gradient over a 6 mm radial distance. In spite of its fabrication simplicity, the fabricated surface demonstrates self-cleaning property, enhanced condensation performance, and reliability over time. Our work enables creation of a hydrophobic condenser surface with the directional self-cleaning property that can be used for collection of biological (chemical, environmental) aerosol samples or for condensation enhancement.

  18. Shop primer as part of the corrosion protective coating for submerged steel structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bjordal, M.; Steinsmo, U.

    In Norwegian workshops the standard pre-treatment procedures for steel structures intended for sub-sea use, normally include removal of shop primer by blast cleaning to Sa 2 1/2 before application of corrosion protective coatings. This is also stated in the Norwegian offshore standard NORSOK. Omitting this stage in fabrication will represent large reductions in both time consumption and costs, and reduce the volume of waste from the blast cleaning. This report presents results from investigations of how a shop primer will influence on the coating properties. The aim of the investigation was to test whether the systems are good enough ifmore » the shop primer is left on the surface. Two different zinc silicate shop primers have been included in the investigation. As protective coatings the authors have used three different epoxy mastic systems with Al pigments. In addition to panels with original shop primer, they have also tested shop primed panels pre-treated in various ways, such as heated, corroded and blast cleaned to various degrees before coating. The coatings have been tested in the ASTM-G8 121 test and in a long term test in sea water polarized with a Zn anode. They have found that coatings including the zinc silicate shop primer are more susceptible to cathodic disbonding than the coating applied directly on blast cleaned steel. It is however possible to meet the NORSOK criteria with a zinc silicate shop primer as first coat.« less

  19. Manual versus automated methods for cleaning reusable accessory devices used for minimally invasive surgical procedures.

    PubMed

    Alfa, M J; Nemes, R

    2004-09-01

    We undertook a simulated-use study using quantitative methods to evaluate the cleaning efficacy of ported and non-ported accessory devices used in minimally invasive surgery. We chose laparoscopic scissors and forceps to represent worst-case devices which were inoculated with artificial test soil containing 10(6) cfu/mL Enterococcus faecalis and Geobacillus stearothermophilus and allowed to dry for 1 h. Cleaning was performed manually, as well as by the automated SI-Auto Narrow lumen cleaner. Manual cleaning left two- to 50-fold more soil residuals (protein, haemoglobin and carbohydrate) inside the lumen of non-ported versus ported laparoscopic accessory devices. The SI-Auto Narrow lumen cleaner was more efficient than manual cleaning and achieved >99% reduction in soil parameters in both non-ported (using retro-flushing) and ported laparoscopic devices. Only the automated cleaning of ported devices achieved 10(3)-10(4)-fold reduction in bacterial numbers. Sonication alone (no flushing of inner channel) did not effectively remove soil or organisms from the inner channel. Our findings indicate that non-ported accessory devices cannot be as reliably cleaned as ported devices regardless of the cleaning method used. If non-ported accessory devices are reprocessed, they should be cleaned using retro-flushing in an automated narrow lumen cleaner.

  20. Supersonic gas-liquid cleaning system

    NASA Technical Reports Server (NTRS)

    Caimi, Raoul E. B.; Thaxton, Eric A.

    1994-01-01

    A system to perform cleaning and cleanliness verification is being developed to replace solvent flush methods using CFC 113 for fluid system components. The system is designed for two purposes: internal and external cleaning and verification. External cleaning is performed with the nozzle mounted at the end of a wand similar to a conventional pressure washer. Internal cleaning is performed with a variety of fixtures designed for specific applications. Internal cleaning includes tubes, pipes, flex hoses, and active fluid components such as valves and regulators. The system uses gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the object to be cleaned. Compressed air or any inert gas may be used to provide the conveying medium for the liquid. The converging-diverging nozzles accelerate the gas-liquid mixture to supersonic velocities. The liquid being accelerated may be any solvent including water. This system may be used commercially to replace CFC and other solvent cleaning methods widely used to remove dust, dirt, flux, and lubricants. In addition, cleanliness verification can be performed without the solvents which are typically involved. This paper will present the technical details of the system, the results achieved during testing at KSC, and future applications for this system.

  1. Supersonic gas-liquid cleaning system

    NASA Astrophysics Data System (ADS)

    Caimi, Raoul E. B.; Thaxton, Eric A.

    1994-02-01

    A system to perform cleaning and cleanliness verification is being developed to replace solvent flush methods using CFC 113 for fluid system components. The system is designed for two purposes: internal and external cleaning and verification. External cleaning is performed with the nozzle mounted at the end of a wand similar to a conventional pressure washer. Internal cleaning is performed with a variety of fixtures designed for specific applications. Internal cleaning includes tubes, pipes, flex hoses, and active fluid components such as valves and regulators. The system uses gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the object to be cleaned. Compressed air or any inert gas may be used to provide the conveying medium for the liquid. The converging-diverging nozzles accelerate the gas-liquid mixture to supersonic velocities. The liquid being accelerated may be any solvent including water. This system may be used commercially to replace CFC and other solvent cleaning methods widely used to remove dust, dirt, flux, and lubricants. In addition, cleanliness verification can be performed without the solvents which are typically involved. This paper will present the technical details of the system, the results achieved during testing at KSC, and future applications for this system.

  2. Tobacco industry consumer research on socially acceptable cigarettes.

    PubMed

    Ling, P M; Glantz, S A

    2005-10-01

    To describe tobacco industry consumer research to inform the development of more "socially acceptable" cigarette products since the 1970s. Analysis of previously secret tobacco industry documents. 28 projects to develop more socially acceptable cigarettes were identified from Philip Morris, RJ Reynolds, British American Tobacco, and Lorillard tobacco companies. Consumer research and concept testing consistently demonstrated that many smokers feel strong social pressure not to smoke, and this pressure increased with exposure to smoking restrictions. Tobacco companies attempted to develop more socially acceptable cigarettes with less visible sidestream smoke or less odour. When presented in theory, these product concepts were very attractive to important segments of the smoking population. However, almost every product developed was unacceptable in actual product tests or test markets. Smokers reported the complete elimination of secondhand smoke was necessary to satisfy non-smokers. Smokers have also been generally unwilling to sacrifice their own smoking satisfaction for the benefit of others. Many smokers prefer smoke-free environments to cigarettes that produce less secondhand smoke. Concerns about secondhand smoke and clean indoor air policies have a powerful effect on the social acceptability of smoking. Historically, the tobacco industry has been unable to counter these effects by developing more socially acceptable cigarettes. These data suggest that educating smokers about the health dangers of secondhand smoke and promoting clean indoor air policies has been difficult for the tobacco industry to counter with new products, and that every effort should be made to pursue these strategies.

  3. Tobacco industry consumer research on socially acceptable cigarettes

    PubMed Central

    Ling, P; Glantz, S

    2005-01-01

    Objective: To describe tobacco industry consumer research to inform the development of more "socially acceptable" cigarette products since the 1970s. Methods: Analysis of previously secret tobacco industry documents. Results: 28 projects to develop more socially acceptable cigarettes were identified from Philip Morris, RJ Reynolds, British American Tobacco, and Lorillard tobacco companies. Consumer research and concept testing consistently demonstrated that many smokers feel strong social pressure not to smoke, and this pressure increased with exposure to smoking restrictions. Tobacco companies attempted to develop more socially acceptable cigarettes with less visible sidestream smoke or less odour. When presented in theory, these product concepts were very attractive to important segments of the smoking population. However, almost every product developed was unacceptable in actual product tests or test markets. Smokers reported the complete elimination of secondhand smoke was necessary to satisfy non-smokers. Smokers have also been generally unwilling to sacrifice their own smoking satisfaction for the benefit of others. Many smokers prefer smoke-free environments to cigarettes that produce less secondhand smoke. Conclusions: Concerns about secondhand smoke and clean indoor air policies have a powerful effect on the social acceptability of smoking. Historically, the tobacco industry has been unable to counter these effects by developing more socially acceptable cigarettes. These data suggest that educating smokers about the health dangers of secondhand smoke and promoting clean indoor air policies has been difficult for the tobacco industry to counter with new products, and that every effort should be made to pursue these strategies. PMID:16183968

  4. Impact of Clean Energy R&D on the U.S. Power Sector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donohoo-Vallett, Paul; Mai, Trieu; Mowers, Matthew

    The U.S. government, along with other governments, private corporations and organizations, invests significantly in research, development, demonstration and deployment (RDD&D) activities in clean energy technologies, in part to achieve the goal of a clean, secure, and reliable energy system. While specific outcomes and breakthroughs resulting from RDD&D investment are unpredictable, it can be instructive to explore the potential impacts of clean energy RDD&D activities in the power sector and to place those impacts in the context of current and anticipated market trends. This analysis builds on and leverages analysis by the U.S. Department of Energy (DOE) titled “Energy CO 2more » Emissions Impacts of Clean Energy Technology Innovation and Policy” (DOE 2017). Similar to DOE (2017), we explore how additional improvements in cost and performance of clean energy technologies could impact the future U.S. energy system; however, unlike the economy-wide modeling used in DOE (2017) our analysis is focused solely on the electricity sector and applies a different and more highly spatially-resolved electric sector model. More specifically, we apply a scenario analysis approach to explore how assumed further advancements in clean electricity technologies would impact power sector generation mix, electricity system costs, and power sector carbon dioxide (CO 2) emissions.« less

  5. Advanced lithographic filtration and contamination control for 14nm node and beyond semiconductor processes

    NASA Astrophysics Data System (ADS)

    Varanasi, Rao; Mesawich, Michael; Connor, Patrick; Johnson, Lawrence

    2017-03-01

    Two versions of a specific 2nm rated filter containing filtration medium and all other components produced from high density polyethylene (HDPE), one subjected to standard cleaning, the other to specialized ultra-cleaning, were evaluated in terms of their cleanliness characteristics, and also defectivity of wafers processed with photoresist filtered through each. With respect to inherent cleanliness, the ultraclean version exhibited a 70% reduction in total metal extractables and 90% reduction in organics extractables compared to the standard clean version. In terms of particulate cleanliness, the ultraclean version achieved stability of effluent particles 30nm and larger in about half the time required by the standard clean version, also exhibiting effluent levels at stability almost 90% lower. In evaluating defectivity of blanket wafers processed with photoresist filtered through either version, initial defect density while using the ultraclean version was about half that observed when the standard clean version was in service, with defectivity also falling more rapidly during subsequent usage of the ultraclean version compared to the standard clean version. Similar behavior was observed for patterned wafers, where the enhanced defect reduction was primarily of bridging defects. The filter evaluation and actual process-oriented results demonstrate the extreme value in using filtration designed possessing the optimal intrinsic characteristics, but with further improvements possible through enhanced cleaning processes

  6. 40 CFR 60.255 - Performance tests and other compliance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Transfer Network (TTN) under Emission Measurement Center Preliminary Methods. The monitoring plan approved... be recorded and quantified. The optical surfaces exposed to the effluent gases must be cleaned prior... adjustments. For systems using automatic zero adjustments, the optical surfaces must be cleaned when the...

  7. The Effectiveness of Power Tool Cleaning as an Alternative to Abrasive Blasting

    DTIC Science & Technology

    1995-06-01

    Lamar Avenue Houston, TX 77251 3M Building Service and Cleaning Products Division Building 223-65-03 St. Paul, MN 55144-1000 Marindus Company P. O...Mill Scale Removal with 3M Brand Heavy Duty RotoPeen Flap Wheel”;”Scotch-Brite” Surface Conditioning Products, 3M Building Service and Cleaning ... Products Division. 18. “The Dilemma of Removing Lead-Based Paint,” January 1988, p. 34-35. Specifications: ASTM TEST METHODS: B1 17, Salt Spray (Fog

  8. Development of Self-Cleaning Denim Fabrics

    NASA Astrophysics Data System (ADS)

    Uğur, Ş. S.; Sarıışık, A. M.; Çavuşlar, E.; Ertek, M.

    2017-10-01

    Denim fabrics coated with TiO2 nanolayers for self-cleaning properties by using a continuous layer-by-layer method. Nanolayer coated denim fabrics washed with an enzyme process for aging affect. Fabrics were analyzed with SEM-EDX and XPS measurements. Self-cleaning properties of the nanolayer deposited denim fabrics were tested according to red wine stain against to Suntest visible light irradiation after 72 h. And also, some physical (air permeability, tensile strength) and color (color difference and rubbing fastness) properties were evaluated.

  9. Comparison of washer-disinfector cleaning indicators: impact of temperature and cleaning cycle parameters.

    PubMed

    Alfa, Michelle J; Olson, Nancy

    2014-02-01

    Because automated instrument washer-disinfectors (WD) are widely used in health care to reprocess a variety of medical instruments, we developed a study to compare 3 cleaning indicators to determine whether they detected suboptimal temperature, time, enzymatic detergent, and fluid action in a washer-disinfector. The Miele WD was used for this comparison. One optimal cycle and 14 cycles with suboptimal enzymatic detergent, cleaning time, temperature, or inactive spray arms were evaluated. The cleaning indicators evaluated included the following: Pinnacle Monitor for Automated Enzymatic Cleaning Process (PNCL), Wash-Checks (WC), and TOSI. The scoring system for all 3 indicators was harmonized to a common scale. Soiled tweezers were included in each cycle evaluated. The PNCL, TOSI, and WC cleaning indicators showed significantly more failures at 40°C compared with 60°C (100% vs 0% for PNCL, 17% vs 0% for TOSI, and 60% vs 22% for WC, respectively). There were significantly more failures at suboptimal temperatures with a 2- versus 4-minute cycle (100% vs 0% for PNCL, 17% vs 0% for TOSI, and 17% vs 0% for WC, respectively, for 40°C cycles). Despite suboptimal cleaning cycles, all soiled tweezers looked clean. All 3 cleaning indicators responded to suboptimal WD conditions; however, the PNCL was the most affected by alterations in the cycle conditions evaluated. In simulated use testing, cleaning indicators provided a more sensitive audit tool compared with visual inspection of soiled instruments after automated cleaning. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  10. Evaluation of Non-Ozone-Depleting-Chemical Cleaning Methods for Space Mechanisms Using a Vacuum Spiral Orbit Rolling Contact Tribometer

    NASA Technical Reports Server (NTRS)

    Jansen, Mark J.; Jones, William R., Jr.; Wheeler, Donald R.; Keller, Dennis J.

    2000-01-01

    Because CFC 113, an ozone depleting chemical (ODC), can no longer be produced, alternative bearing cleaning methods must be studied. The objective of this work was to study the effect of the new cleaning methods on lubricant lifetime using a vacuum bearing simulator (spiral orbit rolling contact tribometer). Four alternative cleaning methods were studied: ultra-violet (UV) ozone, aqueous levigated alumina slurry (ALAS), super critical fluid (SCF) CO2 and aqueous Brulin 815GD. Baseline tests were done using CFC 113. Test conditions were the following: a vacuum of at least 1.3 x 10(exp -6) Pa, 440C steel components, a rotational speed of 10 RPM, a lubricant charge of between 60-75 micrograms, a perfluoropolyalkylether lubricant (Z-25), and a load of 200N (44.6 lbs., a mean Hertzian stress of 1.5 GPa). Normalized lubricant lifetime was determined by dividing the total number of ball orbits by the amount of lubricant. The failure condition was a friction coefficient of 0.38. Post-test XPS analysis was also performed, showing slight variations in post-cleaning surface chemistry. Statistical analysis of the resultant data was conducted and it was determined that the data sets were most directly comparable when subjected to a natural log transformation. The natural log life (NL-Life) data for each cleaning method were reasonably normally (statistically) distributed and yielded standard deviations that were not significantly different among the five cleaning methods investigated. This made comparison of their NL-Life means very straightforward using a Bonferroni multiple comparison of means procedure. This procedure showed that the ALAS, UV-ozone and CFC 113 methods were not statistically significantly different from one another with respect to mean NL-Life. It also found that the SCF CO2 method yielded a significantly higher mean NL-Life than the mean NL-Lives of the ALAS, UV-ozone and CFC 113 methods. It also determined that the aqueous Brulin 815GD method yielded a mean NL-Life that was statistically significantly higher than the mean NL-Lives of each of the other four methods. Baseline tests using CFC 113 cleaned parts yielded a mean NL-Life 3.62 orbits/micro-g. ALAS and UV-ozone yielded similar mean NL-Life (3.31 orbits/mg and 3.33 orbits/micro-g, respectively). SCF CO2, gave a mean NL-Life of 4.08 orbits/mg and aqueous Brulin 8l5GD data yielded the longest mean NL-Life (4.66 orbits/micro-g).

  11. Innovative method and apparatus for the deep cleaning of soluble salts from mortars and lithic materials

    NASA Astrophysics Data System (ADS)

    Gaggero, Laura; Ferretti, Maurizio; Torrielli, Giulia; Caratto, Valentina

    2016-04-01

    Porous materials (e.g. plasters, mortars, concrete, and the like) used in the building industry or in artworks fail to develop, after their genesis, salts such as nitrates, carbonates (e.g. potassium carbonate, magnesium carbonate, calcium carbonate), chlorides (e.g. sodium chloride) and/or others, which are a concurrent cause of material deterioration phenomena. In the case of ancient or cultural heritage buildings, severe damage to structures and works of art, such as fresco paintings are possible. In general, in situ alteration pattern in mortars and frescoes by crystallization of soluble salts from solutions is caused by capillar rise or circulation in damp walls. Older buildings can be more subject to capillary rise of ion-rich waters, which, as water evaporates, create salt crystals inside the walls. If this pattern reveals overwhelming upon other environmental decay factors, the extraction of salts is the first restoration to recover the artpiece after the preliminary assessment and mitigation of the causes of soaking. A new method and apparatus, patented by University of Genoa [1] improves the quality and durability of decontamination by soluble salts, compared with conventional application of sepiolite or cellulose wraps. The conventional application of cellulose or sepiolite requires casting a more or less thick layer of wrap on the mortar, soaking with distilled water, and waiting until dry. The soluble salts result trapped within the wrap. A set of artificial samples reproducing the stratigraphy of frescoes was contaminated with saline solution of known concentration. The higher quality of the extraction was demonstrated by trapping the salts within layers of Japanese paper juxtaposed to the mortar; the extraction with the dedicated apparatus was operated in a significantly shorter time than with wraps (some hours vs. several days). Two cycles of about 15 minutes are effective in the deep cleaning from contaminant salts. The decontamination was demonstrated by conducibility tests on the juxtaposed Japanese paper. In addition, after the conventional treatment, a considerable amount of soluble salts was further extracted demonstrating that traditional wraps operate just a shallow cleaning, and soluble salts are liable to emerge later as efflorescence affecting the conservation after restoration. The optimum cleaning was obtained by finishing the innovative extraction with sepiolite/cellulose wraps. As a whole, the novel method and apparatus enhance the time for restoration and the final quality before consolidation and protection. [1] "Apparatus and method for treating porous materials" - M. Ferretti, L. Gaggero, G. Torrielli, PCT/IB2015/055129 (2015)

  12. The isolated chicken eye test as a suitable in vitro method for determining the eye irritation potential of household cleaning products.

    PubMed

    Schutte, K; Prinsen, M K; McNamee, P M; Roggeband, R

    2009-08-01

    Eye irritation is an important endpoint in the safety evaluation of consumer products and their ingredients. Several in vitro methods have been developed and are used by different industry sectors to assess eye irritation. One such in vitro method in use for some time already is the isolated chicken eye test (ICE). This investigation focuses on assessing the ICE as a method to determine the eye irritation potential of household cleaning products, both for product safety assurance prior to marketing and for classification and labeling decisions. The ICE involves a single application of test substances onto the cornea of isolated chicken eyes. Endpoints are corneal swelling, corneal opacity and fluorescein retention. The ICE results were compared to historic LVET data in this study due to availability of such in vivo data and the ability to correlate LVET to human experience data on the outcome of accidental exposures to household cleaning products in general. The results of this study indicate that the ICE test is a useful in vitro method for evaluating the eye irritation/corrosion potential and establishing classification and labeling for household cleaning products. For new product formulations, it is best used as part of a weight-of-evidence approach and benchmarked against data from comparable formulations with known eye irritation/corrosion profiles and market experience.

  13. An erosion sensor based on a quartz crystal microbalance for quantitative determination of the cleaning efficiency in an ultrasonic vessel.

    PubMed

    Jüschke, M; Koch, C; Dreyer, T

    2014-09-01

    The efficiency of ultrasonic cleaning vessels cannot be measured directly in an easy way. In the presented work, a sensor is developed which quantitatively measures the ablation of a test layer. The sensor element is a quartz crystal which is coated with a sacrificial layer. Small changes in mass of this layer can be measured by a frequency shift of the crystal oscillation. For measurements, a 10 MHz AT-cut quartz crystal was used in a cleaning vessel working at 44.9 kHz. To determine the frequency shift by the ablation of the test layer, the quartz crystal was driven by a frequency generator sweeping the frequency in the range of the resonance frequency and a characteristic frequency was determined. The test layer which was applied to the quartz crystal consisted of silica microparticles suspended in varnish. In a preliminary experiment using a commercial cleaner it could be shown that significant changes in resonance frequency by cavitation effect could be detected. The initial frequency shift of the sacrificial layer is reproducible within 10%. The test layer can be adapted to the conditions of the cleaning vessel. By changing the electrical input power of the vessel, a threshold in the cavitation erosion was found. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Effect of Daily Contact Lens Cleaning on Ocular Adverse Events during Extended Wear.

    PubMed

    Ozkan, Jerome; Rathi, Varsha M; de la Jara, Percy Lazon; Naduvilath, Thomas; Holden, Brien A; Willcox, Mark D P

    2015-02-01

    The purpose of the study was to assess what effect daily cleaning of contact lenses with a multipurpose disinfection solution (MPDS), during 30 nights extended wear, would have on contact lens-related adverse events. This was a prospective, open-label, randomized, controlled, parallel-group, 3-month clinical study in which 193 participants were dispensed with lotrafilcon A silicone hydrogel lenses for a 30-day extended-wear schedule and with lenses replaced monthly. Participants were randomized to a control or test group. Test subjects were required to remove lenses daily after waking, clean them with the MPDS, and reinsert the lenses. Control subjects wore lenses without removal for 30 days extended wear. Handling-related lens contamination was assessed at the baseline visit. There was no significant difference between the test and control groups for the incidence of significant corneal infiltrative events (1.3 vs. 4.9%, p = 0.368), total corneal infiltrative events (2.6 vs. 4.9%, p = 0.682), or mechanical events (1.3 vs. 2.5%, p = 1.00). The test group had greater corneal staining (p < 0.047) and fewer mucin balls (p = 0.033). Handling-related lens contamination (unworn lenses) resulted in isolation of Gram-positive bacteria from 92.5% of test lenses compared with 87.5% of control lenses (p = 0.712). Gram-negative bacteria were isolated from 5% of test subjects compared with 2.5% of control subjects (p = 1.00). Fungus was isolated from 2.5% of subjects in both the test and control groups (p = 1.00). The intervention of daily morning cleaning of the lens surface with an MPDS during extended wear did not significantly influence the incidence of adverse events.

  15. Analysis of the Effects of Vitiates on Surface Heat Flux in Ground Tests of Hypersonic Vehicles

    NASA Technical Reports Server (NTRS)

    Cuda, Vincent; Gaffney, Richard L

    2008-01-01

    To achieve the high enthalpy conditions associated with hypersonic flight, many ground test facilities burn fuel in the air upstream of the test chamber. Unfortunately, the products of combustion contaminate the test gas and alter gas properties and the heat fluxes associated with aerodynamic heating. The difference in the heating rates between clean air and a vitiated test medium needs to be understood so that the thermal management system for hypersonic vehicles can be properly designed. This is particularly important for advanced hypersonic vehicle concepts powered by air-breathing propulsion systems that couple cooling requirements, fuel flow rates, and combustor performance by flowing fuel through sub-surface cooling passages to cool engine components and preheat the fuel prior to combustion. An analytical investigation was performed comparing clean air to a gas vitiated with methane/oxygen combustion products to determine if variations in gas properties contributed to changes in predicted heat flux. This investigation started with simple relationships, evolved into writing an engineering-level code, and ended with running a series of CFD cases. It was noted that it is not possible to simultaneously match all of the gas properties between clean and vitiated test gases. A study was then conducted selecting various combinations of freestream properties for a vitiated test gas that matched clean air values to determine which combination of parameters affected the computed heat transfer the least. The best combination of properties to match was the free-stream total sensible enthalpy, dynamic pressure, and either the velocity or Mach number. This combination yielded only a 2% difference in heating. Other combinations showed departures of up to 10% in the heat flux estimate.

  16. Colour stability of denture teeth submitted to different cleaning protocols and accelerated artificial aging.

    PubMed

    Freire, T S; Aguilar, F G; Garcia, L da Fonseca Roberti; Pires-de-Souza, F de Carvalho Panzeri

    2014-03-01

    Acrylic resin is widely used for artificial teeth manufacturing due to several important characteristics; however, this material do not present acceptable colour stability over the course of time. This study evaluated the effect of different cleaning protocols and accelerated artificial aging on colour stability of denture teeth made of acrylic resin. Sixty denture teeth in dark and light shades were used, and separated according to the treatment to which they were submitted. Results demonstrated that colour stability of artificial teeth is influenced by the cleaning solution and artificial aging, being dark teeth more susceptible to colour alteration than lighter ones.

  17. Low-temperature wafer direct bonding of silicon and quartz glass by a two-step wet chemical surface cleaning

    NASA Astrophysics Data System (ADS)

    Wang, Chenxi; Xu, Jikai; Zeng, Xiaorun; Tian, Yanhong; Wang, Chunqing; Suga, Tadatomo

    2018-02-01

    We demonstrate a facile bonding process for combining silicon and quartz glass wafers by a two-step wet chemical surface cleaning. After a post-annealing at 200 °C, strong bonding interfaces with no defects or microcracks were obtained. On the basis of the detailed surface and bonding interface characterizations, the bonding mechanism was explored and discussed. The amino groups terminated on the cleaned surfaces might contribute to the bonding strength enhancement during the annealing. This cost-effective bonding process has great potentials for silicon- and glass-based heterogeneous integrations without requiring a vacuum system.

  18. CLEAN HYDROGEN TECHNOLOGY FOR 3-WHEEL TRANSPORTATION IN INDIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishna Sapru

    2005-11-15

    Hydrogen is a clean burning, non-polluting transportation fuel. It is also a renewable energy carrier that can be produced from non-fossil fuel resources such as solar, wind and biomass. Utilizing hydrogen as an alternative fuel for vehicles will diversify the resources of energy, and reduce dependence on oil in the transportation sector. Additionally, clean burning hydrogen fuel will also alleviate air pollution that is a very severe problem in many parts of world, especially major metropolitan areas in developing countries, such as India and China. In our efforts to foster international collaborations in the research, development, and demonstration of hydrogenmore » technologies, through a USAID/DOE cost-shared project, Energy Conversion Devices, Inc.,(www.ovonic.com) a leading materials and alternative energy company, in collaboration with Bajaj Auto Limited, India's largest three-wheeler taxi manufacturer, has successfully developed and demonstrated prototype hydrogen ICE three-wheelers in the United States and India. ECD's proprietary Ovonic solid-state hydrogen storage technology is utilized on-board to provide a means of compact, low pressure, and safe hydrogen fuel. These prototype hydrogen three-wheelers have demonstrated comparable performance to the original CNG version of the vehicle, achieving a driving range of 130 km. The hydrogen storage system capable of storing 1 kg hydrogen can be refilled to 80% of its capacity in about 15 minutes at a pressure of 300 psi. The prototype vehicles developed under this project have been showcased and made available for test rides to the public at exhibits such as the 16th NHA annual meeting in April 2005, Washington, DC, and the SIAM (Society of Indian Automotive Manufacturers) annual conference in August 2005, New Delhi, India. Passengers have included members of the automotive industry, founders of both ECD and Bajaj, members of the World Bank, the Indian Union Minister for Finance, the President of the Asia Development Bank, members of USAID, USDOE and many other individuals, all of whom have had praise for the vehicle and the technology. The progress made through this phase I work and the importance of hydrogen three-wheelers has also resulted in extensive press coverage by the news media around the world.« less

  19. Human and Environmental Toxicity of Sodium Lauryl Sulfate (SLS): Evidence for Safe Use in Household Cleaning Products.

    PubMed

    Bondi, Cara Am; Marks, Julia L; Wroblewski, Lauren B; Raatikainen, Heidi S; Lenox, Shannon R; Gebhardt, Kay E

    2015-01-01

    Environmental chemical exposure is a major concern for consumers of packaged goods. The complexity of chemical nomenclature and wide availability of scientific research provide detailed information but lends itself to misinterpretation by the lay person. For the surfactant sodium lauryl sulfate (SLS), this has resulted in a misunderstanding of the environmental health impact of the chemical and statements in the media that are not scientifically supported. This review demonstrates how scientific works can be misinterpreted and used in a manner that was not intended by the authors, while simultaneously providing insight into the true environmental health impact of SLS. SLS is an anionic surfactant commonly used in consumer household cleaning products. For decades, this chemical has been developing a negative reputation with consumers because of inaccurate interpretations of the scientific literature and confusion between SLS and chemicals with similar names. Here, we review the human and environmental toxicity profiles of SLS and demonstrate that it is safe for use in consumer household cleaning products.

  20. Human and Environmental Toxicity of Sodium Lauryl Sulfate (SLS): Evidence for Safe Use in Household Cleaning Products

    PubMed Central

    Bondi, Cara AM; Marks, Julia L; Wroblewski, Lauren B; Raatikainen, Heidi S; Lenox, Shannon R; Gebhardt, Kay E

    2015-01-01

    Environmental chemical exposure is a major concern for consumers of packaged goods. The complexity of chemical nomenclature and wide availability of scientific research provide detailed information but lends itself to misinterpretation by the lay person. For the surfactant sodium lauryl sulfate (SLS), this has resulted in a misunderstanding of the environmental health impact of the chemical and statements in the media that are not scientifically supported. This review demonstrates how scientific works can be misinterpreted and used in a manner that was not intended by the authors, while simultaneously providing insight into the true environmental health impact of SLS. SLS is an anionic surfactant commonly used in consumer household cleaning products. For decades, this chemical has been developing a negative reputation with consumers because of inaccurate interpretations of the scientific literature and confusion between SLS and chemicals with similar names. Here, we review the human and environmental toxicity profiles of SLS and demonstrate that it is safe for use in consumer household cleaning products. PMID:26617461

  1. Chemical Reactions Triggered Using Electrons Photodetached from "Clean" Distributions of Anions Deposited in Cryogenic Matrices via Counterion Codeposition.

    PubMed

    Ludwig, Ryan M; Moore, David T

    2014-09-04

    Application of matrix isolation spectroscopy to ionic species is typically complicated by the presence of neutral contaminants during matrix deposition. Herein we demonstrate that simultaneous deposition of balanced currents of counterions with mass-selected ions of interest generates "clean" distributions of matrix-isolated metal carbonyl anions, where the only bands appearing in the CO-stretching region of the vibrational spectrum arise from ions. (Neutrals are initially absent.) Photodetachment by mild irradiation with visible light leads to complete conversion of the anions into their corresponding neutral species. The photodetached electrons, in turn, initiate covalent chemistry, inducing C-C bond formation following electron-capture by CO van der Waals dimers to produce trans-OCCO(-). The initial clean distribution of ions enables clear connections to be drawn between the spectral changes occurring at each experimental step, thus demonstrating the potential of the counterion codeposition technique to facilitate detailed studies of chemistry involving ions and electron transfer in cryogenic matrices.

  2. Radiation-Resistant Hybrid Lotus Effect for Achieving Photoelectrocatalytic Self-Cleaning Anticontamination Coatings

    NASA Technical Reports Server (NTRS)

    Taylor, Edward W.; Pirich, Ronald G.

    2011-01-01

    An experiment involving radiation-resistant hydrophobic coatings is planned for space exposure and experimental testing on the International Space Station (ISS) in 2011. The Lotus biocide coatings are designed for supporting space exploration missions. This innovation is an antibacterial, anti-contamination, and self-cleaning coating that uses nano-sized semiconductor semimetal oxides to neutralize biological pathogens and toxic chemicals, as well as to mitigate dust accumulation (see figure). The Lotus biocide coating is thin (approximately microns thick), lightweight, and the biocide properties will not degrade with time or exposure to biological or chemical agents. The biocide is stimulated chemically (stoichiometric reaction) through exposure to light (photocatalysis), or by an applied electric field (electrocatalysis). The hydrophobic coating samples underwent preliminary high-energy proton and alpha-ray (helium ion) irradiations at the Lawrence Berkeley National Laboratory 88" cyclotron and demonstrated excellent radiation resistance for a portion of the Galactic Cosmic Ray (GRC) and Solar Proton spectrum. The samples will undergo additional post-flight studies when returned to Earth to affirm further the radiation resistance properties of the space exposed coatings.

  3. High throughput determination of cleaning solutions to prevent the fouling of an anion exchange resin.

    PubMed

    Elich, Thomas; Iskra, Timothy; Daniels, William; Morrison, Christopher J

    2016-06-01

    Effective cleaning of chromatography resin is required to prevent fouling and maximize the number of processing cycles which can be achieved. Optimization of resin cleaning procedures, however, can lead to prohibitive material, labor, and time requirements, even when using milliliter scale chromatography columns. In this work, high throughput (HT) techniques were used to evaluate cleaning agents for a monoclonal antibody (mAb) polishing step utilizing Fractogel(®) EMD TMAE HiCap (M) anion exchange (AEX) resin. For this particular mAb feed stream, the AEX resin could not be fully restored with traditional NaCl and NaOH cleaning solutions, resulting in a loss of impurity capacity with resin cycling. Miniaturized microliter scale chromatography columns and an automated liquid handling system (LHS) were employed to evaluate various experimental cleaning conditions. Cleaning agents were monitored for their ability to maintain resin impurity capacity over multiple processing cycles by analyzing the flowthrough material for turbidity and high molecular weight (HMW) content. HT experiments indicated that a 167 mM acetic acid strip solution followed by a 0.5 M NaOH, 2 M NaCl sanitization provided approximately 90% cleaning improvement over solutions containing solely NaCl and/or NaOH. Results from the microliter scale HT experiments were confirmed in subsequent evaluations at the milliliter scale. These results identify cleaning agents which may restore resin performance for applications involving fouling species in ion exchange systems. In addition, this work demonstrates the use of miniaturized columns operated with an automated LHS for HT evaluation of chromatographic cleaning procedures, effectively decreasing material requirements while simultaneously increasing throughput. Biotechnol. Bioeng. 2016;113: 1251-1259. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  4. Push-out tests on a new silicon carbide/reaction-bonded silicon carbide ceramic matrix composite

    NASA Technical Reports Server (NTRS)

    Curtin, William A.; Eldridge, Jeffrey I.; Srinivasan, Gajawalli V.

    1993-01-01

    Fiber push-out tests have been performed on a ceramic matrix composite consisting of carborundum-sintered SiC fibers, with a BN coating, embedded in a reaction-bonded SiC matrix. Analysis of the push-out data, utilizing the most complete theory presently available, shows that one of the fiber/coating/matrix interfaces has a low fracture energy (one-tenth that of the fiber) and a moderate sliding resistance of about 8 MPa. The debonded sliding interface shows some continuous but minor abrasion, which appears to increase the sliding resistance, but overall the system exhibits very clean smooth sliding. The tensile response of a full-scale composite is then modeled using data obtained here and known fiber strengths to demonstrate the good composite behavior predicted for this material.

  5. FY 2003 Acquisition and Technology Division Annual Report

    DTIC Science & Technology

    2004-08-01

    readiness. The Army will be better able to preserve readiness, save money, and avoid bad decisions by knowing which alternative cleaning products meet its...USAEC and ATC are leading an initiative to comprehensively test several cleaning products and gather data the Army and other DoD services can use to

  6. FY 2002 Pollution Prevention/Compliance, Acquisition and Technology Division Annual Report

    DTIC Science & Technology

    2003-03-03

    will be better able to preserve readiness, save money and avoid bad decisions by knowing which alternative cleaning products meet its stringent...partnership with commodity managers, USAEC and ATC are leading an initiative to compre- hensively test several cleaning products and gather data the Army

  7. FY 2001 Pollution Prevention/Compliance, Acquisition and Technology Division Annual Report

    DTIC Science & Technology

    2002-02-15

    readiness, save money and avoid bad decisions by knowing which alternative cleaning products meet its stringent requirements for performance, soldier...several cleaning products and gather data the Army and other DoD services can use to make procurement and usage decisions. The current program test

  8. Quiet Clean Short-haul Experimental Engine (QCSEE) Over-The-Wing (OTW) propulsion systems test report. Volume 4: Acoustic performance

    NASA Technical Reports Server (NTRS)

    Stimpert, D. L.

    1979-01-01

    A series of acoustic tests were conducted on the over the wing engine. These tests evaluated the fully suppressed noise levels in forward and reverse thrust operation and provided insight into the component noise sources of the engine plus the suppression achieved by various components. System noise levels using the contract specified calculation procedure indicate that the in-flight noise level on a 152 m sideline at takeoff and approach are 97.2 and 94.6 EPNdB, respectively, compared to a goal of 95.0 EPNdB. In reverse thrust, the system noise level was 106.1 PNdB compared to a goal of 100 PNdB. Baseline source noise levels agreed very well with pretest predictions. Inlet-radiated noise suppression of 14 PNdB was demonstrated with the high throat Mach number inlet at 0.79 throat Mach number.

  9. Validation of cleaning method for various parts fabricated at a Beryllium facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Cynthia M.

    This study evaluated and documented a cleaning process that is used to clean parts that are fabricated at a beryllium facility at Los Alamos National Laboratory. The purpose of evaluating this cleaning process was to validate and approve it for future use to assure beryllium surface levels are below the Department of Energy’s release limits without the need to sample all parts leaving the facility. Inhaling or coming in contact with beryllium can cause an immune response that can result in an individual becoming sensitized to beryllium, which can then lead to a disease of the lungs called chronic berylliummore » disease, and possibly lung cancer. Thirty aluminum and thirty stainless steel parts were fabricated on a lathe in the beryllium facility, as well as thirty-two beryllium parts, for the purpose of testing a parts cleaning method that involved the use of ultrasonic cleaners. A cleaning method was created, documented, validated, and approved, to reduce beryllium contamination.« less

  10. Comparison of laser regimes for stamp cleaning

    NASA Astrophysics Data System (ADS)

    Radvan, Roxana N.; Dan, Suzana; Popovici, Nicoleta; Striber, J.; Savastru, Dan; Savastru, Roxana

    2001-10-01

    This paper presents a comparative study of the laser cleaning regimes applied to colored substrates with various chromatic characteristics, including colored paper and printed paper with different dpi (dots per inch) values. Tests are done under microscope with high precision techniques, using controlled Nd:YAG laser. The wavelength preponderantly used in the experiments is the Nd:YAG fundamental regime (1064 nm). Parallel experiments at 532 nm have been developed on difficult cases, or when the results were not satisfactory with 1064 nm. The main part of the work presents some results on stamp cleaning. Experimental results indicate that cleaning efficiency is correlated with the color of substrate, age of the ink on the stamp, color quality and paper quality.

  11. Weatherization and Intergovernmental Programs Office FY 2017 Budget At-A-Glance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-03-01

    The Weatherization and Intergovernmental Programs (WIP) Office is part of EERE’s balanced research, development, demonstration, and deployment approach to accelerate America’s transition to a clean energy economy. WIP’s mission is to partner with state and local organizations to improve energy security and to significantly accelerate the deployment of clean energy technologies and practices by a wide range of government, community, and business stakeholders.

  12. Bench-scale performance testing and economic analyses of electrostatic dry coal cleaning. Final report, October 1980-July 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rich, S.R.

    1987-02-01

    The report gives results of preliminary performance evaluations and economic analyses of the Advanced Energy Dynamics (AED) electrostatic dry coal-cleaning process. Grab samples of coal-feed-product coals were obtained from 25 operating physical coal-cleaning (PCC) plants. These samples were analyzed for ash, sulfur, and energy content and splits of the original samples of feed run-of-mine coal were provided for bench-scale testing in an electrostatic separation apparatus. The process showed superior sulfur-removal performance at equivalent cost and energy-recovery levels. The ash-removal capability of the process was not evaluated completely: overall, ash-removal results indicated that the process did not perform as well asmore » the PCC plants.« less

  13. Simple Activity Demonstrates Wind Energy Principles

    ERIC Educational Resources Information Center

    Roman, Harry T.

    2012-01-01

    Wind energy is an exciting and clean energy option often described as the fastest-growing energy system on the planet. With some simple materials, teachers can easily demonstrate its key principles in their classroom. (Contains 1 figure and 2 tables.)

  14. Tolerance of Salmonella Enteritidis and Staphylococcus aureus to surface cleaning and household bleach.

    PubMed

    Kusumaningrum, H D; Paltinaite, R; Koomen, A J; Hazeleger, W C; Rombouts, F M; Beumer, R R

    2003-12-01

    Effective cleaning and sanitizing of food preparation sites is important because pathogens are readily spread to food contact surfaces after preparation of contaminated raw products. Tolerance of Salmonella Enteritidis and Staphylococcus aureus to surface cleaning by wiping with regular, microfiber, and antibacterial-treated cloths was investigated. Wiping with cleaning cloths resulted in a considerable reduction of microorganisms from surfaces, despite the greater difficulty in removing S. aureus than Salmonella Enteritidis. Depending on the cloth type, S. aureus were reduced on surfaces from initial numbers of approximately 10(5) CFU/100 cm2 to numbers from less than 4 CFU/100 cm2 (below the detection limit) to 100 CFU/100 cm2. Directly after the cloths were used to clean the contaminated surfaces, they contained high numbers of bacteria (10(4) to 10(5) CFU/100 cm2), except for the disposable antibacterial-treated cloths, in which no bacteria could be detected. The tolerance of these pathogens to sodium hypochlorite was studied in the suspension test and in cloths. S. aureus showed a better tolerance for sodium hypochlorite than Salmonella Enteritidis. Inactivation of microorganisms in cloths required a higher concentration of sodium hypochlorite than was needed in the suspension test. Repeated exposure to sodium hypochlorite, however, resulted in an increase in susceptibility to this compound. This study provides essential information about the transfer of bacteria when wiping surfaces and highlights the need for a hygiene procedure with cleaning cloths that sufficiently avoids cross-contamination in the household environment.

  15. The direct liquefaction proof of concept program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Comolli, A.G.; Lee, L.K.; Pradhan, V.R.

    1995-12-31

    The goal of the Proof of Concept (POC) Program is to develop Direct Coal Liquefaction and associated transitional technologies towards commercial readiness for economically producing premium liquid fuels from coal in an environmentally acceptable manner. The program focuses on developing the two-stage liquefaction (TSL) process by utilizing geographically strategic feedstocks, commercially feasible catalysts, new prototype equipment, and testing co-processing or alternate feedstocks and improved process configurations. Other high priority objectives include dispersed catalyst studies, demonstrating low rank coal liquefaction without solids deposition, improving distillate yields on a unit reactor volume basis, demonstrating ebullated bed operations while obtaining scale-up data, demonstratingmore » optimum catalyst consumption using new concepts (e.g. regeneration, cascading), producing premium products through on-line hydrotreating, demonstrating improved hydrogen utilization for low rank coals using novel heteroatom removal methods, defining and demonstrating two-stage product properties for upgrading; demonstrating efficient and economic solid separation methods, examining the merits of integrated coal cleaning, demonstrating co-processing, studying interactions between the preheater and first and second-stage reactors, improving process operability by testing and incorporating advanced equipment and instrumentation, and demonstrating operation with alternate coal feedstocks. During the past two years major PDU Proof of Concept runs were completed. POC-1 with Illinois No. 6 coal and POC-2 with Black Thunder sub-bituminous coal. Results from these operations are continuing under review and the products are being further refined and upgraded. This paper will update the results from these operations and discuss future plans for the POC program.« less

  16. Optimizing the use of surfactants and water with foams: a comparison between soapy solutions and foams for sebum detergency

    NASA Astrophysics Data System (ADS)

    Restagno, Frederic; Valois, Pauline; Petit, Pauline; Cazeneuve, Colette; Nicolas-Morgantini, Luc; Rio, Emmnauelle; Luengo, Gustavo

    Human sebum is excreted at the skin surface by the sebaceous glands. Surfactants are the core ingredients of shampoos and other cosmetics to eliminate the excess of sebum as detergency is the classical mechanism used for hair cleaning.. In this study, we add a precise amount of sebum on different hair. We developed a new protocol to measure the cleaning efficiency of surfactant solutions and foams made with the same surfactant solutions based on a spectroscopic method. More precisely, we add a well-controlled amount of colored sebum, we clean the hair with our test foam or solution and we remove completely the unwashed sebum. The sebum remaining after washing is quantified by visible spectroscopy. We tested either classical detergents such as SLES at different concentrations or white egg. The studies were performed on natural or bleached hair. In all the studied case, it was not possible to observe any difference in the cleaning efficiency between the bulk solutions and the foams made from the solutions. This study could allow to develop new shampoos formulations or dispensers in order to replace washing solutions by foams that could have the same cleaning efficiency with a lower amount of surfactants; diminishing the water rinsing needs during application.

  17. Engineers Clean Mirror with Carbon Dioxide Snow

    NASA Image and Video Library

    2015-01-22

    Just like drivers sometimes use snow to clean their car mirrors in winter, two Exelis Inc. engineers are practicing "snow cleaning'" on a test telescope mirror for the James Webb Space Telescope at NASA's Goddard Space Flight Center in Greenbelt, Maryland. By shooting carbon dioxide snow at the surface, engineers are able to clean large telescope mirrors without scratching them. "The snow-like crystals (carbon dioxide snow) knock contaminate particulates and molecules off the mirror," said Lee Feinberg, NASA optical telescope element manager. This technique will only be used if the James Webb Space Telescope's mirror is contaminated during integration and testing. The Webb telescope is the scientific successor to NASA's Hubble Space Telescope. It will be the most powerful space telescope ever built. With a mirror seven times as large as Hubble's and infrared capability, Webb will be capturing light from 13.5 billion light years away. To do this, its mirror must be kept super clean. "Small dust particles or molecules can impact the science that can be done with the Webb," said Feinberg. "So cleanliness especially on the mirrors is critical." Webb is an international project led by NASA with its partners, the European Space Agency and the Canadian Space Agency. Image credit: NASA/Goddard/Chris Gunn

  18. Effectiveness of UV-C light irradiation on disinfection of an eSOS(®) smart toilet evaluated in a temporary settlement in the Philippines.

    PubMed

    Zakaria, Fiona; Harelimana, Bertin; Ćurko, Josip; van de Vossenberg, Jack; Garcia, Hector A; Hooijmans, Christine Maria; Brdjanovic, Damir

    2016-01-01

    Ultraviolet germicidal (short wavelength UV-C) light was studied as surface disinfectant in an Emergency Sanitation Operation System(®) smart toilet to aid to the work of manual cleaning. The UV-C light was installed and regulated as a self-cleaning feature of the toilet, which automatically irradiate after each toilet use. Two experimental phases were conducted i.e. preparatory phase consists of tests under laboratory conditions and field testing phase. The laboratory UV test indicated that irradiation for 10 min with medium-low intensity of 0.15-0.4 W/m(2) could achieve 6.5 log removal of Escherichia coli. Field testing of the toilet under real usage found that UV-C irradiation was capable to inactivate total coliform at toilet surfaces within 167-cm distance from the UV-C lamp (UV-C dose between 1.88 and 2.74 mW). UV-C irradiation is most effective with the support of effective manual cleaning. Application of UV-C for surface disinfection in emergency toilets could potentially reduce public health risks.

  19. Transition through co-optation: Harnessing carbon democracy for clean energy

    NASA Astrophysics Data System (ADS)

    Meng, Kathryn-Louise

    This dissertation explores barriers to a clean energy transition in the United States. Clean energy is demonstrably viable, yet the pace of clean energy adoption in the U.S. is slow, particularly given the immediate threat of global climate change. The purpose of this dissertation is to examine the factors inhibiting a domestic energy transition and to propose pragmatic approaches to catalyzing a transition. The first article examines the current political-economic and socio-technical energy landscape in the U.S. Fossil fuels are central to the functioning of the American economy. Given this centrality, constellations of power have been constructed around the reliable and affordable access of fossil fuels. The fossil fuel energy regime is comprised of: political-economic networks with vested interests in continued fossil fuel reliance, and fixed infrastructure that is minimally compatible with distributed generation. A transition to clean energy threatens the profitability of fossil fuel regime actors. Harnessing structural critiques from political ecology and process and function-oriented socio-technical systems frameworks, I present a multi-level approach to identifying pragmatic means to catalyzing an energy transition. High-level solutions confront the existing structure, mid-level solutions harness synergy with the existing structure, and low-level solutions lie outside of the energy system or foster the TIS. This is exemplified using a case study of solar development in Massachusetts. Article two presents a case study of the clean energy technological innovation system (TIS) in Massachusetts. I examine the actors and institutions that support cleantech development. Further, I scrutinize the actors and institutions that help sustain the TIS support system. The concept of a catalyst is presented; a catalyst is an actor that serves to propel TIS functions. Catalysts are critical to facilitating anchoring. Strategic corporate partners are identified as powerful catalysts that can help infuse capital into the TIS, propel TIS functions, and facilitate anchoring to the socio-technical regime and landscape. In the final article I argue that the environmental narrative that traditionally frames the need for clean energy is ineffective. Environmental narratives are antagonistic towards powerful actors and institutions discussed in the first article. Such antagonism can impede the development of clean energy incentives, decelerating a transition to clean energy. The need for clean energy can be reframed according to a security discourse. I demonstrate the compatibility between clean energy development and national security imperatives and argue that security imperatives are more likely to receive legislative and financial support than environmental imperatives. Ultimately I argue that geographers can find utility in the very structures, institutions, and actors that they critique. Capitalist imperatives of profit and growth can be harnessed so as to appeal to strategic corporate partners. The military, its budget, industrial complex, and research and development resources can in fact be beneficial to developing clean energy domestically.

  20. Examining factors that influence the effectiveness of cleaning antineoplastic drugs from drug preparation surfaces: a pilot study.

    PubMed

    Hon, Chun-Yip; Chua, Prescillia Ps; Danyluk, Quinn; Astrakianakis, George

    2014-06-01

    Occupational exposure to antineoplastic drugs has been documented to result in various adverse health effects. Despite the implementation of control measures to minimize exposure, detectable levels of drug residual are still found on hospital work surfaces. Cleaning these surfaces is considered as one means to minimize the exposure potential. However, there are no consistent guiding principles related to cleaning of contaminated surfaces resulting in hospitals to adopt varying practices. As such, this pilot study sought to evaluate current cleaning protocols and identify those factors that were most effective in reducing contamination on drug preparation surfaces. Three cleaning variables were examined: (1) type of cleaning agent (CaviCide®, Phenokil II™, bleach and chlorhexidine), (2) application method of cleaning agent (directly onto surface or indirectly onto a wipe) and (3) use of isopropyl alcohol after cleaning agent application. Known concentrations of antineoplastic drugs (either methotrexate or cyclophosphamide) were placed on a stainless steel swatch and then, systematically, each of the three cleaning variables was tested. Surface wipes were collected and quantified using high-performance liquid chromatography-tandem mass spectrometry to determine the percent residual of drug remaining (with 100% being complete elimination of the drug). No one single cleaning agent proved to be effective in completely eliminating all drug contamination. The method of application had minimal effect on the amount of drug residual. In general, application of isopropyl alcohol after the use of cleaning agent further reduced the level of drug contamination although measureable levels of drug were still found in some cases.

Top