Sample records for cleanliness analysis tool

  1. Tools for measuring surface cleanliness

    DOEpatents

    Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank

    2002-01-01

    A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.

  2. The adenosine triphosphate method as a quality control tool to assess 'cleanliness' of frequently touched hospital surfaces.

    PubMed

    Knape, L; Hambraeus, A; Lytsy, B

    2015-10-01

    The adenosine triphosphate (ATP) method is widely accepted as a quality control method to complement visual assessment, in the specifications of requirements, when purchasing cleaning contractors in Swedish hospitals. To examine whether the amount of biological load, as measured by ATP on frequently touched near-patient surfaces, had been reduced after an intervention; to evaluate the correlation between visual assessment and ATP levels on the same surfaces; to identify aspects of the performance of the ATP method as a tool in evaluating hospital cleanliness. A prospective intervention study in three phases was carried out in a medical ward and an intensive care unit (ICU) at a regional hospital in mid-Sweden between 2012 and 2013. Existing cleaning procedures were defined and baseline tests were sampled by visual inspection and ATP measurements of ten frequently touched surfaces in patients' rooms before and after intervention. The intervention consisted of educating nursing staff about the importance of hospital cleaning and direct feedback of ATP levels before and after cleaning. The mixed model showed a significant decrease in ATP levels after the intervention (P < 0.001). Relative light unit values were lower in the ICU. Cleanliness as judged by visual assessments improved. In the logistic regression analysis, there was a significant association between visual assessments and ATP levels. Direct feedback of ATP levels, together with education and introduction of written cleaning protocols, were effective tools to improve cleanliness. Visual assessment correlated with the level of ATP but the correlation was not absolute. The ATP method could serve as an educational tool for staff, but is not enough to assess hospital cleanliness in general as only a limited part of a large area is covered. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Surface cleanliness measurement procedure

    DOEpatents

    Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank

    2002-01-01

    A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.

  4. Technical Tension Between Achieving Particulate and Molecular Organic Environmental Cleanliness: Data from Astromaterial Curation Laboratories

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Burkett, P. J.

    2011-01-01

    NASA Johnson Space Center operates clean curation facilities for Apollo lunar, Antarctic meteorite, stratospheric cosmic dust, Stardust comet and Genesis solar wind samples. Each of these collections is curated separately due unique requirements. The purpose of this abstract is to highlight the technical tensions between providing particulate cleanliness and molecular cleanliness, illustrated using data from curation laboratories. Strict control of three components are required for curating samples cleanly: a clean environment; clean containers and tools that touch samples; and use of non-shedding materials of cleanable chemistry and smooth surface finish. This abstract focuses on environmental cleanliness and the technical tension between achieving particulate and molecular cleanliness. An environment in which a sample is manipulated or stored can be a room, an enclosed glovebox (or robotic isolation chamber) or an individual sample container.

  5. Alternative Nonvolatile Residue Analysis with Contaminant Identification Project

    NASA Technical Reports Server (NTRS)

    Loftin, Kathleen (Compiler); Summerfield, Burton (Compiler); Thompson, Karen (Compiler); Mullenix, Pamela (Compiler); Zeitlin, Nancy (Compiler)

    2015-01-01

    Cleanliness verification is required in numerous industries including spaceflight ground support, electronics, medical and aerospace. Currently at KSC requirement for cleanliness verification use solvents that environmentally unfriendly. This goal of this project is to produce an alternative cleanliness verification technique that is both environmentally friendly and more cost effective.

  6. MANTECH Project Book

    DTIC Science & Technology

    1991-01-01

    degrade due to thermal cyclingmultiple repairs, and/or corrosion. Depending on the service history and alloy, reduced properties result from carbide U...subsystem 91 titanitun alloys 85 cleanliness gas turbine engines 85 titani •-n aluminide 81 tolerance control 92 tool breaqkage 95 tool fracture 95 tools

  7. The effect of cleanliness control during installation work on the amount of accumulated dust in ducts of new HVAC installations.

    PubMed

    Holopainen, R; Tuomainen, M; Asikainen, V; Pasanen, P; Säteri, J; Seppänen, O

    2002-09-01

    The aim of this study was to evaluate the amount of dust in supply air ducts in recently installed ventilation systems. The samples for the determination of dust accumulation were collected from supply air ducts in 18 new buildings that have been constructed according to two different cleanliness control levels classified as category P1 (low oil residues and protected against contaminations) and category P2, as defined in the Classification of Indoor Climate, Construction and Building Materials. In the ducts installed according to the requirements of cleanliness category P1 the mean amount of accumulated dust was 0.9 g/m2 (0.4-2.9 g/m2), and in the ducts installed according to the cleanliness category P2 it was 2.3 g/m2 (1.2-4.9 g/m2). A significant difference was found in the mean amounts of dust between ducts of categories P1 and P2 (P < 0.008). The cleanliness control procedure in category P1 proved to be a useful and effective tool for preventing dust accumulation in new air ducts during the construction process. Additionally, the ducts without residual oil had lower amounts of accumulated dust indicating that the demand for oil free components in the cleanliness classification is reasonable.

  8. Racial Disparities in Cleanliness Attitudes Mediate Purchasing Attitudes Toward Cleaning Products: a Serial Mediation Model.

    PubMed

    Litman, Leib; Williams, Monnica T; Rosen, Zohn; Weinberger-Litman, Sarah L; Robinson, Jonathan

    2017-09-22

    The present study has three objectives (1) to examine whether there are differences in cleanliness concerns between African Americans and European Americans toward kitchen items that are known to be vectors of disease, (2) to examine whether disparities in cleanliness attitudes have an impact on purchasing attitudes toward kitchen cleaning products, and (3) to explore the mechanisms that may account for these differences utilizing a serial mediation model. Five hundred participants, 50% African American and 50% European American were shown a picture of a sponge cleaning product and filled out multiple survey instruments relating to cleanliness attitudes. We found greater concern with cleanliness of kitchen items (d = .46) and a greater willingness to purchase cleaning products among African Americans compared to European Americans (17 vs 10%). A serial mediation analysis revealed that general cleanliness concerns account for the increased willingness to spend money on cleaning products among African Americans. These results suggest that African Americans are more sensitive to issues of cleanliness compared to European Americans and, in particular, are more sensitive to cleanliness of kitchen items such as sponges, which can be vectors of food-borne pathogens. Potential reasons for the observed racial disparities in cleanliness attitudes and the implications of these results for public health are discussed.

  9. The Mars Science Laboratory Organic Check Material

    NASA Astrophysics Data System (ADS)

    Conrad, Pamela G.; Eigenbrode, Jennifer L.; Von der Heydt, Max O.; Mogensen, Claus T.; Canham, John; Harpold, Dan N.; Johnson, Joel; Errigo, Therese; Glavin, Daniel P.; Mahaffy, Paul R.

    2012-09-01

    Mars Science Laboratory's Curiosity rover carries a set of five external verification standards in hermetically sealed containers that can be sampled as would be a Martian rock, by drilling and then portioning into the solid sample inlet of the Sample Analysis at Mars (SAM) suite. Each organic check material (OCM) canister contains a porous ceramic solid, which has been doped with a fluorinated hydrocarbon marker that can be detected by SAM. The purpose of the OCM is to serve as a verification tool for the organic cleanliness of those parts of the sample chain that cannot be cleaned other than by dilution, i.e., repeated sampling of Martian rock. SAM possesses internal calibrants for verification of both its performance and its internal cleanliness, and the OCM is not used for that purpose. Each OCM unit is designed for one use only, and the choice to do so will be made by the project science group (PSG).

  10. Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?

    PubMed

    Stella, Judith; Hurt, Moriah; Bauer, Amy; Gomes, Paulo; Ruple, Audrey; Beck, Alan; Croney, Candace

    2018-04-21

    Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli . Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring types investigated.

  11. An index to quantify street cleanliness: the case of Granada (Spain).

    PubMed

    Sevilla, Aitana; Rodríguez, Miguel Luis; García-Maraver, Angela; Zamorano, Montserrat

    2013-05-01

    Urban surfaces receive waste deposits from natural and human sources, which create a negative visual impact and are identified as potentially significant contributors to water and air pollution. Local councils are usually responsible for the sweep of roads and footpaths to keep the environment clean and free of litter. Quality controls are useful in order to check whether the services are being executed according to the quantity, quality and performance standards that are provided. In this sense, several factors might affect the efficiency of the management of cleaning and waste collection services; however, only a few contributions are available in the literature on the various aspects associated with the level of street cleanliness. In this paper, the suitability of a Cleanliness Index has been checked, for the case of Granada (South of Spain), in order to contribute to the proper management of public expenditure, improving the quality and cost of an essential service for any municipality. Results have concluded that the city exhibits a good level of cleanliness, although the standard of cleaning varied from one area of the city to another. The Cleaning Index fits well to the general situation of the different districts of Granada and thus, it could be considered a useful tool for measuring the level of cleanliness of the streets of the city and for evaluating the organization of the cleaning service, such that an outsourced company would not be responsible for controlling all the cleaning services. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.

    2016-01-01

    It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 milligrams per square meter, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems, however, vary considerably, notably within the aerospace industry. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

  13. Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.

    2016-01-01

    It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 mg/sq m, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems vary considerably. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

  14. Cleaning and Cleanliness Measurement of Additive Manufactured Parts

    NASA Technical Reports Server (NTRS)

    Mitchell, Mark A.; Raley, Randy

    2016-01-01

    The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surfaces of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The methods for establishing objective cleanliness acceptance limits will be discussed.

  15. Contamination-Free Manufacturing: Tool Component Qualification, Verification and Correlation with Wafers

    NASA Astrophysics Data System (ADS)

    Tan, Samantha H.; Chen, Ning; Liu, Shi; Wang, Kefei

    2003-09-01

    As part of the semiconductor industry "contamination-free manufacturing" effort, significant emphasis has been placed on reducing potential sources of contamination from process equipment and process equipment components. Process tools contain process chambers and components that are exposed to the process environment or process chemistry and in some cases are in direct contact with production wafers. Any contamination from these sources must be controlled or eliminated in order to maintain high process yields, device performance, and device reliability. This paper discusses new nondestructive analytical methods for quantitative measurement of the cleanliness of metal, quartz, polysilicon and ceramic components that are used in process equipment tools. The goal of these new procedures is to measure the effectiveness of cleaning procedures and to verify whether a tool component part is sufficiently clean for installation and subsequent routine use in the manufacturing line. These procedures provide a reliable "qualification method" for tool component certification and also provide a routine quality control method for reliable operation of cleaning facilities. Cost advantages to wafer manufacturing include higher yields due to improved process cleanliness and elimination of yield loss and downtime resulting from the installation of "bad" components in process tools. We also discuss a representative example of wafer contamination having been linked to a specific process tool component.

  16. Both Intrinsic and Extrinsic Religious Orientation are Positively Associated with Attitudes Toward Cleanliness: Exploring Multiple Routes from Godliness to Cleanliness.

    PubMed

    Litman, Leib; Robinson, Jonathan; Weinberger-Litman, Sarah L; Finkelstein, Ron

    2017-08-24

    In the present study, we explore how intrinsic and extrinsic religious orientations are associated with cleanliness attitudes. We find that reported importance of religion is associated with increased cleanliness concerns and interest in cleanliness. Attitudes toward cleanliness were also associated with both intrinsic religious orientation and extrinsic religious orientation. Together, religiosity and religious orientation account for 14.7% of cleanliness attitudes and remained significant in the presence of personality, socioeconomic status, age, education, obsessive-compulsive attitudes toward cleanliness, and other covariates. These results show that religiosity is associated with cleanliness via multiple routes. We suggest that intrinsic religious orientation leads to increased interest in cleanliness due to the link between physical and spiritual purity. Extrinsic religious orientation may be linked with cleanliness because of the secondary benefits, including health and the facilitation in communal cohesiveness, that cleanliness rituals offer. The implications of these findings for the relationship between religion and health are discussed.

  17. Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?

    PubMed Central

    Stella, Judith; Hurt, Moriah; Bauer, Amy; Croney, Candace

    2018-01-01

    Simple Summary It is important to understand how the flooring substrate used in dog housing impacts dog health and well-being. Aspects to consider include paw, elbow, and hock health, the cleanliness of the dog, and the ability of the floors to be cleaned easily and thoroughly. This pilot study assessed the health and cleanliness of 118 dogs housed on three different types of flooring commonly found in commercial breeding kennels. No serious paw, elbow, or hock problems were identified. Thirty-one percent or fewer kennels at each facility were found to have fecal contamination after routine cleaning and the majority of dogs were clean. These findings indicate that a well-managed kennel can maintain clean, healthy dogs on different types of flooring substrates. Abstract Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli. Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring types investigated. PMID:29690514

  18. Cleaning and Cleanliness Measurement of Additive Manufactured Parts

    NASA Technical Reports Server (NTRS)

    Welker, Roger W.; Mitchell, Mark A.

    2015-01-01

    The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surface of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The six commonly used methods for establishing objective cleanliness acceptance limits will be discussed. Special emphasis shall focus on the use of multiple extraction, a technique that has been demonstrated for additively manufactured parts.

  19. OCICATS (Online Community Input Classification to Advance Transportation Services) - a GIS-based decision-support tool.

    DOT National Transportation Integrated Search

    2016-09-02

    Public transportation agencies can obtain large amounts of information regarding timeliness, efficiency, cleanliness, ridership, and other : performance measures. However, these metrics are based on the interests of these agencies and do not necessar...

  20. [Psychology of Hygiene: Rsult of a Comparative Study 1968/1976 (author's transl)].

    PubMed

    Bergler, R

    1976-01-01

    Object of the investigation is: (1) the analysis of the behaviour observed in adults between 18 and 23 years of age regarding cleanliness, body hygiene and changing of underwear,and a comparison of the results with those for 1968; (2) Differential "diagnosis" of the relationship between the degree of cleanliness and the various styles of the upbringing received at the hands of the parents, the different assessment of the personal body image and of cleanliness-related values ("cleanliness ideology"). Main results of the investigation (1) In 1976, too, women remain cleaner than men; the latter, however, have clearly improved their daily washing habits (lower part of the body, feet) and have taken to changing their underwear, night clothes and coloured shirts more frequently. With respect to the frequency with which women change their underwear there has been no change. (2) With respect to body hygiene and cosmetic care, women are found to be making increasing use of mouth-wash, foam bath agents, face lotions and face milk, nail polish, while men are making more use of mouth-wash, bubble bath agents as well as deodorants. In contrast, women are making less use of lip-sticks, eyebrow pencils, Eau de Cologne, (3) Women's behaviour with respect to the observed and evaluated parental upbringing and to their own body image is more differentiated: The 4-factor solution for women contrasts with the 3-factor solution for men. (4) Only a form of cleanliness training involving corporal punishment and associated with a tense or hostile relationship towards the mother or father cannot be correlated to a desirable observance of cleanliness. Other possible forms of cleanliness training including supervisory forms, do not prevent the learning and adoption of desirable practices for achieving cleanliness. (5) Less clean women show a generally less pronounced body-feeling as manifested in active physical exercise in some sports disciplines and in body care. There is also a tendency towards a less motivating criticism of the figure and a lower degree of positive bodily sensibility. As far as men are concerned, the intensity of body hygiene is positively linked with the degree of superficial good grooming and the simultaneous dissatisfaction with the figure. (6) Cleanliness-related concepts (cleanliness ideology) e.g. health, work, generosity rectitude, authority, attractiveness, integrity etc., are, in their evaluation, influenced both by sex and by the hygienic behavior practiced.

  1. Cleanliness Policy Implementation: Evaluating Retribution Model to Rise Public Satisfaction

    NASA Astrophysics Data System (ADS)

    Dailiati, Surya; Hernimawati; Prihati; Chintia Utami, Bunga

    2018-05-01

    This research is based on the principal issues concerning the evaluation of cleanliness retribution policy which has not been optimally be able to improve the Local Revenue of Pekanbaru City and has not improved the cleanliness of Pekanbaru City. It was estimated to be caused by the performance of Garden and Sanitation Department are not in accordance with the requirement of society of Pekanbaru City. The research method used in this study is a mixed method with sequential exploratory strategy. The data collection used are observation, interview and documentation for qualitative research as well as questionnaires for quantitative research. The collected data were analyzed with interactive model of Miles and Huberman for qualitative research and multiple regression analysis for quantitative research. The research result indicated that the model of cleanliness policy implementation that can increase of PAD Pekanbaru City and be able to improve people’s satisfaction divided into two (2) which are the evaluation model and the society satisfaction model. The evaluation model influence by criteria/variable of effectiveness, efficiency, adequacy, equity, responsiveness, and appropriateness, while the society satisfaction model influence by variables of society satisfaction, intentions, goals, plans, programs, and appropriateness of cleanliness retribution collection policy.

  2. ADDRESSING EMERGING ISSUES IN WATER QUALITY THROUGH ENVIRONMENTAL CHEMISTRY

    EPA Science Inventory

    Public concern over cleanliness and safety of source and recreational waters has prompted researchers to look for indicators of water quality. Giving public water authorities multiple tools to measure and monitor levels of chemical contaminants, as well as chemical markers of c...

  3. High-radiance LDP source for mask inspection and beam line applications (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Teramoto, Yusuke; Santos, Bárbara; Mertens, Guido; Kops, Ralf; Kops, Margarete; von Wezyk, Alexander; Bergmann, Klaus; Yabuta, Hironobu; Nagano, Akihisa; Ashizawa, Noritaka; Taniguchi, Yuta; Yamatani, Daiki; Shirai, Takahiro; Kasama, Kunihiko

    2017-04-01

    High-throughput actinic mask inspection tools are needed as EUVL begins to enter into volume production phase. One of the key technologies to realize such inspection tools is a high-radiance EUV source of which radiance is supposed to be as high as 100 W/mm2/sr. Ushio is developing laser-assisted discharge-produced plasma (LDP) sources. Ushio's LDP source is able to provide sufficient radiance as well as cleanliness, stability and reliability. Radiance behind the debris mitigation system was confirmed to be 120 W/mm2/sr at 9 kHz and peak radiance at the plasma was increased to over 200 W/mm2/sr in the recent development which supports high-throughput, high-precision mask inspection in the current and future technology nodes. One of the unique features of Ushio's LDP source is cleanliness. Cleanliness evaluation using both grazing-incidence Ru mirrors and normal-incidence Mo/Si mirrors showed no considerable damage to the mirrors other than smooth sputtering of the surface at the pace of a few nm per Gpulse. In order to prove the system reliability, several long-term tests were performed. Data recorded during the tests was analyzed to assess two-dimensional radiance stability. In addition, several operating parameters were monitored to figure out which contributes to the radiance stability. The latest model that features a large opening angle was recently developed so that the tool can utilize a large number of debris-free photons behind the debris shield. The model was designed both for beam line application and high-throughput mask inspection application. At the time of publication, the first product is supposed to be in use at the customer site.

  4. Asthma and the hygiene hypothesis. Does cleanliness matter?

    PubMed

    Weber, Juliane; Illi, Sabina; Nowak, Dennis; Schierl, Rudolf; Holst, Otto; von Mutius, Erika; Ege, Markus J

    2015-03-01

    The early hygiene hypothesis explained the development of allergies by a lack of infections; nowadays, the aspect of excessive cleanliness in affluent populations seems to have replaced this concept. Yet, no investigation has shown that home or personal cleanliness relate to allergic diseases. To relate personal and home cleanliness to risk of asthma and allergies. Comprehensive questionnaire information on home or personal cleanliness and allergic health conditions at school age was collected in 399 participants of the urban Perinatale Asthma Umwelt Langzeit Allergie Studie (PAULA) birth cohort. Bacterial markers were assessed in floor and mattress dust and were related to cleanliness and allergic diseases. Personal cleanliness was inversely related to bacterial compounds on floors and mattresses, whereas home cleanliness effectively reduced dust amount but not microbial markers. Exposure to muramic acid related to a lower prevalence of school-age asthma (adjusted odds ratio, 0.59 [95% confidence interval, 0.39; 0.90]). Mattress endotoxin in the first year of life was inversely associated with atopic sensitization (0.73 [0.56-0.96]) and asthma at school age (0.72 [0.55-0.95]). Despite the associations of dust parameters both with cleanliness and allergic health conditions, the development of allergies was not related to home and personal cleanliness. Bacterial exposure in house dust determined childhood asthma and allergies. Personal cleanliness, such as washing hands, and home cleanliness were objectively reflected by dust parameters in homes. However, neither personal nor home cleanliness was associated with a risk for asthma and allergies. Other microbial components in house dust not affected by personal hygiene are likely to play a role.

  5. Precision Clean Hardware: Maintenance of Fluid Systems Cleanliness

    NASA Technical Reports Server (NTRS)

    Sharp, Sheila; Pedley, Mike; Bond, Tim; Quaglino, Joseph; Lorenz, Mary Jo; Bentz, Michael; Banta, Richard; Tolliver, Nancy; Golden, John; Levesque, Ray

    2003-01-01

    The ISS fluid systems are so complex that fluid system cleanliness cannot be verified at the assembly level. A "build clean / maintain clean" approach was used by all major fluid systems: Verify cleanliness at the detail and subassembly level. Maintain cleanliness during assembly.

  6. The diminiode: A research and development tool for nuclear thermionics

    NASA Technical Reports Server (NTRS)

    Morris, J. F.

    1972-01-01

    Diminiodes are fixed-or variable-gap cesium diodes with plane miniature emitters and guarded collectors. In addition to smallness, their relative advantages are simplicity, precision, ease of fabrication, interchangeability of parts, cleanliness, full instrumentation, ruggedness, and economy. With diminiodes and computers used in thermionic performance mapping, a thorough electrode screening program becomes practical.

  7. Surface cleanliness of fluid systems, specification for

    NASA Technical Reports Server (NTRS)

    1995-01-01

    This specification establishes surface cleanliness levels, test methods, cleaning and packaging requirements, and protection and inspection procedures for determining surface cleanliness. These surfaces pertain to aerospace parts, components, assemblies, subsystems, and systems in contact with any fluid medium.

  8. Cleanliness inspection tool for RSRM bond surfaces

    NASA Technical Reports Server (NTRS)

    Mattes, Robert A.

    1995-01-01

    Using optically stimulated electron emission (OSEE), Thiokol has monitored bond surfaces in process for contamination on the Redesigned Solid Rocket Motor (RSRM). This technique provides process control information to help assure bond surface quality and repeatability prior to bonding. This paper will describe OSEE theory of operation and the instrumentation implemented at Thiokol Corporation since 1987. Data from process hardware will be presented.

  9. Air pollution: Household soiling and consumer welfare losses

    USGS Publications Warehouse

    Watson, W.D.; Jaksch, J.A.

    1982-01-01

    This paper uses demand and supply functions for cleanliness to estimate household benefits from reduced particulate matter soiling. A demand curve for household cleanliness is estimated, based upon the assumption that households prefer more cleanliness to less. Empirical coefficients, related to particulate pollution levels, for shifting the cleanliness supply curve, are taken from available studies. Consumer welfare gains, aggregated across 123 SMSAs, from achieving the Federal primary particulate standard, are estimated to range from $0.9 to $3.2 million per year (1971 dollars). ?? 1982.

  10. The importance of cleanliness in a proper construction site management in malaysia: a contractor’s perspective

    NASA Astrophysics Data System (ADS)

    Shazwan, M. A.; Quintin, J. V.; Osman, N. A.; Suhaida, S. K.; Ma'arof, M. I. N.

    2017-11-01

    Construction site’s cleanliness and tidiness is one of top main concerns of construction site management. A good site management with adequate planning in regards to housekeeping will ensure safety to both the site’s working personnel and the neighbouring environment. This is especially of priority today due to the rapid growth of construction projects in Malaysia. Nevertheless, to date, statistics had shown that housekeeping related accidents happened repeatedly despite the awareness on site’s cleanliness and tidiness. The objective of this study was to explore constructor’s perspective on site cleanliness and tidiness. A set of questionnaire was distributed to thirty-four (34) Grade 7 CIDB contractors’ firms in Petaling Jaya. Petaling Jaya was chosen since this area are developed area covered with residential area and cleaning management an importance issues. The goals of the survey study were to identify the following items from the perception of the contractors: (i) the hierarchy of importance of several purposes in ensuring construction site’s cleanliness and tidiness, and (ii) the risk factors that influence a construction site’s level of cleanliness and tidiness. It was found that from the contractor’s perspective, ensuring a site cleanliness and tidiness is of importance mainly due to the need in protecting the environment, whilst, the least in cost saving. In addition, poor personnel’s working attitude was found to be the main risk factor that will influences a construction site’s level of cleanliness and tidiness. Conclusively, construction site’s cleanliness and tidiness is highly vital. Even so, for nationwide awareness on the topic matter will requires full cooperation from all related parties.

  11. 49 CFR 174.715 - Cleanliness of transport vehicles after use.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Cleanliness of transport vehicles after use. 174... RAIL Detailed Requirements for Class 7 (Radioactive) Materials § 174.715 Cleanliness of transport vehicles after use. (a) Each transport vehicle used for transporting Class 7 (radioactive) materials as...

  12. 49 CFR 174.715 - Cleanliness of transport vehicles after use.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Cleanliness of transport vehicles after use. 174... RAIL Detailed Requirements for Class 7 (Radioactive) Materials § 174.715 Cleanliness of transport vehicles after use. (a) Each transport vehicle used for transporting Class 7 (radioactive) materials as...

  13. Photographic consulting services to the Earth Resources program. [using aerial photography as a tool for scientific measurement

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The recommendations, procedures, and techniques are summarized which provided by the Kodak Apparatus Division to the Ames Research Center to support the Earth Resources Aircraft Program at that facility. Recommendations, procedures, and calibration data are included for sensitometry, densitometry, laboratory cleanliness, and determination of camera exposure. Additional comments are made regarding process control procedures and general laboratory operations.

  14. Inclusion Detection in Aluminum Alloys Via Laser-Induced Breakdown Spectroscopy

    NASA Astrophysics Data System (ADS)

    Hudson, Shaymus W.; Craparo, Joseph; De Saro, Robert; Apelian, Diran

    2018-04-01

    Laser-induced breakdown spectroscopy (LIBS) has shown promise as a technique to quickly determine molten metal chemistry in real time. Because of its characteristics, LIBS could also be used as a technique to sense for unwanted inclusions and impurities. Simulated Al2O3 inclusions were added to molten aluminum via a metal-matrix composite. LIBS was performed in situ to determine whether particles could be detected. Outlier analysis on oxygen signal was performed on LIBS data and compared to oxide volume fraction measured through metallography. It was determined that LIBS could differentiate between melts with different amounts of inclusions by monitoring the fluctuations in signal for elements of interest. LIBS shows promise as an enabling tool for monitoring metal cleanliness.

  15. Using Image Pro Plus Software to Develop Particle Mapping on Genesis Solar Wind Collector Surfaces

    NASA Technical Reports Server (NTRS)

    Rodriquez, Melissa C.; Allton, J. H.; Burkett, P. J.

    2012-01-01

    The continued success of the Genesis mission science team in analyzing solar wind collector array samples is partially based on close collaboration of the JSC curation team with science team members who develop cleaning techniques and those who assess elemental cleanliness at the levels of detection. The goal of this collaboration is to develop a reservoir of solar wind collectors of known cleanliness to be available to investigators. The heart and driving force behind this effort is Genesis mission PI Don Burnett. While JSC contributes characterization, safe clean storage, and benign collector cleaning with ultrapure water (UPW) and UV ozone, Burnett has coordinated more exotic and rigorous cleaning which is contributed by science team members. He also coordinates cleanliness assessment requiring expertise and instruments not available in curation, such as XPS, TRXRF [1,2] and synchrotron TRXRF. JSC participates by optically documenting the particle distributions as cleaning steps progress. Thus, optical document supplements SEM imaging and analysis, and elemental assessment by TRXRF.

  16. Comparison of Sellers's Awareness to Environmental Hygiene of Market Bulak, Market Klender and Market Rawamangun, East Jakarta

    NASA Astrophysics Data System (ADS)

    Maulidya, Hasana P.

    2018-02-01

    This research is motivated by the difference of market hygiene condition, where the market hygiene level is influenced by the environment around the market. In general, markets located near densely populated housing tend to be overlooked, while markets near elite housing tend to be clean. This condition is also influenced by marketers' awareness of market hygiene. If the market is near the elite neighbourhood, the level of awareness of sellers on cleanliness will be high. If the market is located in a densely populated area, sellers generally do not pay attention to cleanliness. The purpose of this research is to know the sellers's awareness of environmental cleanliness of Market Bulak, Klender Market and Rawamangun Market. Respondents in this study are sellers and buyers who make transactions in these 3 markets. This type of research is descriptive analysis with the method of observation and interview to 10 sellers in each market. Seller hygiene awareness are poor.

  17. Hardware cleanliness methodology and certification

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Lash, Thomas J.; Rawls, J. Richard

    1995-01-01

    Inadequacy of mass loss cleanliness criteria for selection of materials for contamination sensitive uses, and processing of flight hardware for contamination sensitive instruments is discussed. Materials selection for flight hardware is usually based on mass loss (ASTM E-595). However, flight hardware cleanliness (MIL 1246A) is a surface cleanliness assessment. It is possible for materials (e.g. Sil-Pad 2000) to pass ASTM E-595 and fail MIL 1246A class A by orders of magnitude. Conversely, it is possible for small amounts of nonconforming material (Huma-Seal conformal coating) to not present significant cleanliness problems to an optical flight instrument. Effective cleaning (precleaning, precision cleaning, and ultra cleaning) and cleanliness verification are essential for contamination sensitive flight instruments. Polish cleaning of hardware, e.g. vacuum baking for vacuum applications, and storage of clean hardware, e.g. laser optics, is discussed. Silicone materials present special concerns for use in space because of the rapid conversion of the outgassed residues to glass by solar ultraviolet radiation and/or atomic oxygen. Non ozone depleting solvent cleaning and institutional support for cleaning and certification are also discussed.

  18. Improved Detection Technique for Solvent Rinse Cleanliness Verification

    NASA Technical Reports Server (NTRS)

    Hornung, S. D.; Beeson, H. D.

    2001-01-01

    The NASA White Sands Test Facility (WSTF) has an ongoing effort to reduce or eliminate usage of cleaning solvents such as CFC-113 and its replacements. These solvents are used in the final clean and cleanliness verification processes for flight and ground support hardware, especially for oxygen systems where organic contaminants can pose an ignition hazard. For the final cleanliness verification in the standard process, the equivalent of one square foot of surface area of parts is rinsed with the solvent, and the final 100 mL of the rinse is captured. The amount of nonvolatile residue (NVR) in the solvent is determined by weight after the evaporation of the solvent. An improved process of sampling this rinse, developed at WSTF, requires evaporation of less than 2 mL of the solvent to make the cleanliness verification. Small amounts of the solvent are evaporated in a clean stainless steel cup, and the cleanliness of the stainless steel cup is measured using a commercially available surface quality monitor. The effectiveness of this new cleanliness verification technique was compared to the accepted NVR sampling procedures. Testing with known contaminants in solution, such as hydraulic fluid, fluorinated lubricants, and cutting and lubricating oils, was performed to establish a correlation between amount in solution and the process response. This report presents the approach and results and discusses the issues in establishing the surface quality monitor-based cleanliness verification.

  19. How Clean Are Hotel Rooms? Part II: Examining the Concept of Cleanliness Standards.

    PubMed

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Hotel room cleanliness is based on observation and not on microbial assessment even though recent reports suggest that infections may be acquired while staying in hotel rooms. Exploratory research in the first part of the authors' study was conducted to determine if contamination of hotel rooms occurs and whether visual assessments are accurate indicators of hotel room cleanliness. Data suggested the presence of microbial contamination that was not reflective of visual assessments. Unfortunately, no standards exist for interpreting microbiological data and other indicators of cleanliness in hotel rooms. The purpose of the second half of the authors' study was to examine cleanliness standards in other industries to see if they might suggest standards in hotels. Results of the authors' study indicate that standards from other related industries do not provide analogous criteria, but do provide suggestions for further research.

  20. Magnetic Testing, and Modeling, Simulation and Analysis for Space Applications

    NASA Technical Reports Server (NTRS)

    Boghosian, Mary; Narvaez, Pablo; Herman, Ray

    2012-01-01

    The Aerospace Corporation (Aerospace) and Lockheed Martin Space Systems (LMSS) participated with Jet Propulsion Laboratory (JPL) in the implementation of a magnetic cleanliness program of the NASA/JPL JUNO mission. The magnetic cleanliness program was applied from early flight system development up through system level environmental testing. The JUNO magnetic cleanliness program required setting-up a specialized magnetic test facility at Lockheed Martin Space Systems for testing the flight system and a testing program with facility for testing system parts and subsystems at JPL. The magnetic modeling, simulation and analysis capability was set up and performed by Aerospace to provide qualitative and quantitative magnetic assessments of the magnetic parts, components, and subsystems prior to or in lieu of magnetic tests. Because of the sensitive nature of the fields and particles scientific measurements being conducted by the JUNO space mission to Jupiter, the imposition of stringent magnetic control specifications required a magnetic control program to ensure that the spacecraft's science magnetometers and plasma wave search coil were not magnetically contaminated by flight system magnetic interferences. With Aerospace's magnetic modeling, simulation and analysis and JPL's system modeling and testing approach, and LMSS's test support, the project achieved a cost effective approach to achieving a magnetically clean spacecraft. This paper presents lessons learned from the JUNO magnetic testing approach and Aerospace's modeling, simulation and analysis activities used to solve problems such as remnant magnetization, performance of hard and soft magnetic materials within the targeted space system in applied external magnetic fields.

  1. Hygiene on maternity units: lessons from a needs assessment in Bangladesh and India

    PubMed Central

    Cross, Suzanne; Afsana, Kaosar; Banu, Morsheda; Mavalankar, Dileep; Morrison, Emma; Rahman, Atiya; Roy, Tapash; Saxena, Deepak; Vora, Kranti; Graham, Wendy J

    2016-01-01

    Background As the proportion of deliveries in health institutions increases in low- and middle-income countries, so do the challenges of maintaining standards of hygiene and preventing healthcare-associated infections (HCAIs) in mothers and babies. Adequate water, sanitation, and hygiene (WASH) and infection prevention and control (IPC) in these settings should be seen as integral parts of the broader domain of quality care. Assessment approaches are needed which capture standards for both WASH and IPC, and so inform quality improvement processes. Design A needs assessment was conducted in seven maternity units in Gujarat, India, and eight in Dhaka Division, Bangladesh in 2014. The WASH & CLEAN study developed and applied a suite of tools – a ‘walkthrough checklist’ which included the collection of swab samples, a facility needs assessment tool and document review, and qualitative interviews with staff and recently delivered women – to establish the state of hygiene as measured by visual cleanliness and the presence of potential pathogens, and individual and contextual determinants or drivers. Results No clear relationship was found between visually assessed cleanliness and the presence of pathogens; findings from qualitative interviews and the facility questionnaire found inadequacies in IPC training for healthcare providers and no formal training at all for ward cleaners. Lack of written policies and protocols, and poor monitoring and supervision also contributed to suboptimal IPC standards. Conclusions Visual assessment of cleanliness and hygiene is an inadequate marker for ‘safety’ in terms of the presence of potential pathogens and associated risk of infection. Routine environmental screening of high-risk touch sites using simple microbiology could improve detection and control of pathogens. IPC training for both healthcare providers and ward cleaners represents an important opportunity for quality improvement. This should occur in conjunction with broader systems changes, including the establishment of functioning IPC committees, implementing standard policies and protocols, and improving health management information systems to capture information on maternal and newborn HCAIs. PMID:27964775

  2. A clean self reduces bribery intent.

    PubMed

    Li, Chao; Liu, Li; Zheng, Wenwen; Dang, Jianning; Liang, Yuan

    2017-08-14

    The present research aimed at investigating the effect of physical cleanliness on bribery intent and the moderating role of personal need for structure (PNS) on this relationship. In Study 1, we used questionnaires to establish the correlation between bodily cleanliness and bribery intent. In Study 2, we examined the effect by priming sense of self-cleanliness. Study 3 was conducted outside a public bath to test our finding that physical purity decreases bribery intent again; we further found that individuals with high PNS showed no reduction in bribery intent even after cleaning themselves. We thus connected physical cleanliness with the corruption field and improved our understanding of its underlying moderating mechanism. © 2017 International Union of Psychological Science.

  3. Contamination control program for the Cosmic Background Explorer

    NASA Technical Reports Server (NTRS)

    Barney, Richard D.

    1991-01-01

    Each of the three state of the art instruments flown aboard NASA's Cosmic Background Explorer (COBE) were designed, fabricated, and integrated using unique contamination control procedures to ensure accurate characterization of the diffuse radiation in the universe. The most stringent surface level cleanliness specifications ever attempted by NASA were required by the Diffuse Infrared Background Experiment (DRIBE) which is located inside a liquid helium cooled dewar along with the Far Infrared Absolute Spectrophotometer (FIRAS). The DRIBE instrument required complex stray radiation suppression that defined a cold primary optical baffle system surface cleanliness level of 100A. The cleanliness levels of the cryogenic FIRAS instrument and the Differential Microwave Radiometer (DMR) which were positioned symmetrically around the dewar were less stringent ranging from 300 to 500A. To achieve these instrument cleanliness levels, the entire flight spacecraft was maintained at level 500A throughout each phase of development. The COBE contamination control program is described along with the difficulties experienced in maintaining the cleanliness quality of personnel and flight hardware throughout instrument assembly.

  4. Comparison of innovative molecular approaches and standard spore assays for assessment of surface cleanliness.

    PubMed

    Cooper, Moogega; La Duc, Myron T; Probst, Alexander; Vaishampayan, Parag; Stam, Christina; Benardini, James N; Piceno, Yvette M; Andersen, Gary L; Venkateswaran, Kasthuri

    2011-08-01

    A bacterial spore assay and a molecular DNA microarray method were compared for their ability to assess relative cleanliness in the context of bacterial abundance and diversity on spacecraft surfaces. Colony counts derived from the NASA standard spore assay were extremely low for spacecraft surfaces. However, the PhyloChip generation 3 (G3) DNA microarray resolved the genetic signatures of a highly diverse suite of microorganisms in the very same sample set. Samples completely devoid of cultivable spores were shown to harbor the DNA of more than 100 distinct microbial phylotypes. Furthermore, samples with higher numbers of cultivable spores did not necessarily give rise to a greater microbial diversity upon analysis with the DNA microarray. The findings of this study clearly demonstrated that there is not a statistically significant correlation between the cultivable spore counts obtained from a sample and the degree of bacterial diversity present. Based on these results, it can be stated that validated state-of-the-art molecular techniques, such as DNA microarrays, can be utilized in parallel with classical culture-based methods to further describe the cleanliness of spacecraft surfaces.

  5. State of personal hygiene among primary school children: A community based cohort study.

    PubMed

    Ahmadu, Baba Usman; Rimamchika, Musa; Ibrahim, Ahmad; Nnanubumom, Andy Angela; Godiya, Andrew; Emmanuel, Pembi

    2013-01-01

    Good personal hygiene in primary school children could be effective towards preventing infectious diseases. This work examined personal cleanliness of primary school children in Banki based on the following variables: bathing, state of uniforms, hair, nails and oral hygiene. One hundred and fifty primary school children in Banki community were selected using the cluster random sampling method. Analysis of variance was used to compare means and to test for significance of data, and coefficient of correlation to investigate the relationship between cleanliness and age of subjects. There were 87 (58 %) boys and 63 (42 %) girls in a ratio of 1.4:1. Ninety six (64 %) pupils belong to low socioeconomic class. Whereas, 53 (35.3 %) were found within 11-13 years age group, the overall mean age was 9 years (Standard deviation [SD] was 2.2), 95 CI (7.0 - 11.0) years. Comparing means for the different categories of personal hygiene, there was significant difference (F= 61.47, p < 0.0001). General personal cleanliness in our participants improved with age, and a positive significant correlation was observed between age and personal cleanliness in (r = 0.971, p = 0.026). In conclusion, significant number of primary school pupils in Banki community had good personal hygiene, which was observed to be directly proportional with age. Therefore, all efforts towards quality health education on personal hygiene as a means of primary prevention of illnesses in primary school pupils should be sustained.

  6. Contamination control and cleanliness level integrity for the Space Shuttle Orbiter PLB, payloads and facilities at KSC

    NASA Technical Reports Server (NTRS)

    Bartelson, D.

    1984-01-01

    The PLB, its cargo, and payload canister must satisfy the cleanliness requirements of visual clean (VC) level 1, 2, 3, or special as stated in NASA document SN-C-0005A. The specific level of cleanliness is chosen by the payload bay customer for their mission. During orbiter turnaround processing at KSC, the payload bay is exposed to the environments of the Orbiter Processing Facility (OPF) and the Payload Changeout Room (PCR). In supportive response to the orbiter payload bay/facility interface, it is necessary that the facility environment be controlled and monitored to protect the cleanliness/environmental integrity of the payload bay and its cargo. Techniques used to meet environmental requirements during orbiter processing are introduced.

  7. Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Zeigler, R. A.; Calaway, M. J.

    2016-01-01

    The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.

  8. Automated Counting of Particles To Quantify Cleanliness

    NASA Technical Reports Server (NTRS)

    Rhode, James

    2005-01-01

    A machine vision system, similar to systems used in microbiological laboratories to count cultured microbes, has been proposed for quantifying the cleanliness of nominally precisely cleaned hardware by counting residual contaminant particles. The system would include a microscope equipped with an electronic camera and circuitry to digitize the camera output, a personal computer programmed with machine-vision and interface software, and digital storage media. A filter pad, through which had been aspirated solvent from rinsing the hardware in question, would be placed on the microscope stage. A high-resolution image of the filter pad would be recorded. The computer would analyze the image and present a histogram of sizes of particles on the filter. On the basis of the histogram and a measure of the desired level of cleanliness, the hardware would be accepted or rejected. If the hardware were accepted, the image would be saved, along with other information, as a quality record. If the hardware were rejected, the histogram and ancillary information would be recorded for analysis of trends. The software would perceive particles that are too large or too numerous to meet a specified particle-distribution profile. Anomalous particles or fibrous material would be flagged for inspection.

  9. Assessing the cleanliness of surfaces: Innovative molecular approaches vs. standard spore assays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, M.; Duc, M.T. La; Probst, A.

    2011-04-01

    A bacterial spore assay and a molecular DNA microarray method were compared for their ability to assess relative cleanliness in the context of bacterial abundance and diversity on spacecraft surfaces. Colony counts derived from the NASA standard spore assay were extremely low for spacecraft surfaces. However, the PhyloChip generation 3 (G3) DNA microarray resolved the genetic signatures of a highly diverse suite of microorganisms in the very same sample set. Samples completely devoid of cultivable spores were shown to harbor the DNA of more than 100 distinct microbial phylotypes. Furthermore, samples with higher numbers of cultivable spores did not necessarilymore » give rise to a greater microbial diversity upon analysis with the DNA microarray. The findings of this study clearly demonstrated that there is not a statistically significant correlation between the cultivable spore counts obtained from a sample and the degree of bacterial diversity present. Based on these results, it can be stated that validated state-of-the-art molecular techniques, such as DNA microarrays, can be utilized in parallel with classical culture-based methods to further describe the cleanliness of spacecraft surfaces.« less

  10. Determination of Root Canal Cleanliness by Different Irrigation Methods and Morphometric Analysis of Apical Third.

    PubMed

    Seixas, Fábio Heredia; Estrela, Carlos; Bueno, Mike Reis; Sousa-Neto, Manoel Damião; Pécora, Jesus Djalma

    2015-06-01

    The aim of this study was to determine the root canal area before and after the instrumentation 1 mm short of the apical foramen by clinical and cone beam computed tomography (CBCT) methods, and to evaluate the cleanliness of the apical region in mesiodistal flattened teeth by using optical microscopy. Forty-two human single-canal mandibular incisors were instrumented using the Free Tip Preparation technique up to three, four or five instruments from the initial. Cone beam computed tomography scans were acquired of the samples before and after root canal preparation (RCP). Irrigation was performed by conventional or hydrodynamic means, using 2.5% sodium hypochlorite. The samples were prepared for observation under an optical microscope. Images were digitally obtained, analyzed and the results were submitted to statistical analysis (two-way ANOVA complemented by Bonferroni's post-test). There was no significant difference between the studied anatomical areas with both CBCT and clinical methods. There were no differences between irrigation methods. It was verified differences between instrumentation techniques. Instrumentation with four instruments from the initial instrument determined a significant increase in the contact area when compared to preparation with three instruments, but RCP with 5 instruments did not result in a better cleanliness. The analysis with CBCT was not capable to determine the precise shape of surgical apical area comparing to the clinical method. Both the conventional and hydrodynamic irrigation techniques were not able to promote root canals debris-free. The instruments action in root canal walls was proportional to the number of instruments used from the initial apical instrument.

  11. Clean and Cold Sample Curation

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Agee, C. B.; Beer, R.; Cooper, B. L.

    2000-01-01

    Curation of Mars samples includes both samples that are returned to Earth, and samples that are collected, examined, and archived on Mars. Both kinds of curation operations will require careful planning to ensure that the samples are not contaminated by the instruments that are used to collect and contain them. In both cases, sample examination and subdivision must take place in an environment that is organically, inorganically, and biologically clean. Some samples will need to be prepared for analysis under ultra-clean or cryogenic conditions. Inorganic and biological cleanliness are achievable separately by cleanroom and biosafety lab techniques. Organic cleanliness to the <50 ng/sq cm level requires material control and sorbent removal - techniques being applied in our Class 10 cleanrooms and sample processing gloveboxes.

  12. The Mars Science Laboratory Organic Check Material

    NASA Technical Reports Server (NTRS)

    Conrad, Pamela G.; Eigenbrode, J. E.; Mogensen, C. T.; VonderHeydt, M. O.; Glavin, D. P.; Mahaffy, P. M.; Johnson, J. A.

    2011-01-01

    The Organic Check Material (OCM) has been developed for use on the Mars Science Laboratory mission to serve as a sample standard for verification of organic cleanliness and characterization of potential sample alteration as a function of the sample acquisition and portioning process on the Curiosity rover. OCM samples will be acquired using the same procedures for drilling, portioning and delivery as are used to study martian samples with The Sample Analysis at Mars (SAM) instrument suite during MSL surface operations. Because the SAM suite is highly sensitive to organic molecules, the mission can better verify the cleanliness of Curiosity's sample acquisition hardware if a known material can be processed through SAM and compared with the results obtained from martian samples.

  13. Effect of Ladle Usage on Cleanliness of Bearing Steel

    NASA Astrophysics Data System (ADS)

    Chi, Yunguang; Deng, Zhiyin; Zhu, Miaoyong

    2018-02-01

    To investigate the effects of ladle usage on the inclusions and total oxygen contents of bearing steel, MgO refractory rods with different glazes were used to simulate different ladle usages. The results show that the effects of different ladle usages on the cleanliness of the steel differ from each other. The total oxygen content of steel increases with the decreasing glaze basicity. Ladle glaze having a lower basicity has a more negative impact on the cleanliness of steel in the subsequent production. Inclusions can be generated by the flush-off of ladle glaze, and the initial glaze is important in the evolution of inclusions in the subsequent heats. To avoid the negative effect of ladle usage and to improve the steel cleanliness as much as possible, specialized ladles were suggested for producing high-quality steel grades.

  14. [Personal hygiene and cleanliness in an international comparison].

    PubMed

    Bergler, R

    1989-04-01

    The investigation was intended to analyse the attitude towards hygiene and cleanliness in the Federal Republic of Germany, France, and Spain. On the basis of a theoretical explanatory model and empirically gained qualitative raw data a standardized questionnaire was prepared; in a number of questions comparability with a study carried out in the Federal Republic of Germany in 1968 was ensured. In all countries the population was subjected to representative random tests (Federal Republic of Germany n = 1016; France n = 517; Spain n = 514). The paper presents a review of the hypothesis that quality and intensity of the cleanliness increases with (1) the extent of personal sensitivity to hygiene in the private, professional and public sphere, (2) with increasing physical sensibility, (3) the increase in our knowledge of hygiene and health, (4) with the increase in the personal behavioral standards for measures concerned with prevention, hygiene of the body, household, underwear and environment, (5) with the increasing weight given to hygiene and toilet during the process of development, and (6) with the extent of regular control of education in cleanliness based on established rules of behavior. The spheres of behavior investigated and mentioned below confirmed the validity of the hypothesis for (1) household hygiene (spring-cleaning, window cleaning, cleaning of the home: dusting, vacuum-cleaning, cleaning of the floor), (2) hygiene of the body (frequency of taking a shower, bathing, toothbrushing, intimate hygiene), (3) hygiene of the laundry (frequency of changing underclothes such as panties/underpants, brassieres, nightgowns/pyjamas, stockings/socks, linen, pillows, dish and kitchen towels). The following general findings were established: (1) In the Federal Republic of Germany the attitude towards hygiene and cleanliness has improved over the last 20 years. (2) The level of hygiene and cleanliness in France and Spain is significantly higher than in the FRG. (3) The use of regular and also strict parental controls of the child's attitude towards cleanliness, as well as the continuity and systematic pursuance of this hygiene-orientated education is far more spread in France and in Spain than in the Federal Republic of Germany. (4) Within the population of a country differences are attributable to the quality of the parental educational efforts, to the importance of sex-specific cleanliness and toilet standards, to the knowledge of or the prejudices against the interrelationship between hygiene, cleanliness and health, the degree of private, public and professional hygiene sensibility, and physical sensibility.(ABSTRACT TRUNCATED AT 400 WORDS)

  15. Cleaning and Cleanliness Verification Techniques for Mars Returned Sample Handling

    NASA Technical Reports Server (NTRS)

    Mickelson, E. T.; Lindstrom, D. J.; Allton, J. H.; Hittle, J. D.

    2002-01-01

    Precision cleaning and cleanliness verification techniques are examined as a subset of a comprehensive contamination control strategy for a Mars sample return mission. Additional information is contained in the original extended abstract.

  16. Evaluation of Contamination Inspection and Analysis Methods through Modeling System Performance

    NASA Technical Reports Server (NTRS)

    Seasly, Elaine; Dever, Jason; Stuban, Steven M. F.

    2016-01-01

    Contamination is usually identified as a risk on the risk register for sensitive space systems hardware. Despite detailed, time-consuming, and costly contamination control efforts during assembly, integration, and test of space systems, contaminants are still found during visual inspections of hardware. Improved methods are needed to gather information during systems integration to catch potential contamination issues earlier and manage contamination risks better. This research explores evaluation of contamination inspection and analysis methods to determine optical system sensitivity to minimum detectable molecular contamination levels based on IEST-STD-CC1246E non-volatile residue (NVR) cleanliness levels. Potential future degradation of the system is modeled given chosen modules representative of optical elements in an optical system, minimum detectable molecular contamination levels for a chosen inspection and analysis method, and determining the effect of contamination on the system. By modeling system performance based on when molecular contamination is detected during systems integration and at what cleanliness level, the decision maker can perform trades amongst different inspection and analysis methods and determine if a planned method is adequate to meet system requirements and manage contamination risk.

  17. Indium adhesion provides quantitative measure of surface cleanliness

    NASA Technical Reports Server (NTRS)

    Krieger, G. L.; Wilson, G. J.

    1968-01-01

    Indium tipped probe measures hydrophobic and hydrophilic contaminants on rough and smooth surfaces. The force needed to pull the indium tip, which adheres to a clean surface, away from the surface provides a quantitative measure of cleanliness.

  18. [Quantitative analysis of factors to influence the environment of the clean room and clean bench during preparation of intravenous hyperalimentation (IVH) admixtures].

    PubMed

    Hotoda, S; Aoyama, T; Sato, A; Yamamura, Y; Nakajima, K; Nakamura, K; Sato, H; Iga, T

    1999-12-01

    We quantitatively studied factors influencing the environment cleanliness for intravenous hyperalimentation (IVH) admixing. The environment cleanliness was evaluated by measuring the counts of particles (> 0.5 micron) and bacteria floating in 1 ft3 of the air inside the clean room (23.6 m3) and in the clean bench built in the department of pharmacy, The University of Tokyo Hospital in 1998. The number of particles at the center of the clean room during IVH admixing by 4 pharmacists was higher than that at the medicine passing area (150 +/- 50/ft3 vs. 260 +/- 60/ft3; mean +/- S.D., n = 12). The cleanliness inside the clean room was improved as the measurement point became higher from the floor (600 +/- 180/ft3, 150 +/- 50/ft3, and 35 +/- 15/ft3 at 50, 100, and 150 cm height, respectively) and the number of persons working inside the room decreased. The changes in the counts of floating bacteria were similar to that of floating particles under the same conditions. In addition the effect of disinfection on the counts of bacteria was clearly observed. When the cleanliness of the room became lower by turning off the air conditioning, the particle counts inside the clean bench became lower along with the distance from the front glass becoming deeper (i.e., 1400 +/- 550/ft3, 140 +/- 70/ft3, and 40 +/- 30/ft3 at 0, 5, and 15 cm, respectively). From these lines of evidence, the following items were suggested in order to maintain the environment cleanliness for IVH admixing. First, the number of persons residing in the clean room should be kept to be minimum. Second, the clean bench should be set up in the center of the clean room. Finally IVH admixing operation should be performed at more than 15 cm depth inside the front glass surface of the clean bench. Moreover, the effect of mopping-up of the clean room with 0.1% benzethonium chloride clearly demonstrated the importance of disinfection on a routine basis.

  19. Associations between Body Mass Index and Park Proximity, Size, Cleanliness and Recreational Facilities

    PubMed Central

    Quinn, James; Lovasi, Gina; Bader, Michael; Yousefzadeh, Paulette; Weiss, Christopher; Neckerman, Kathryn

    2013-01-01

    Purpose To determine whether body mass index (BMI) is associated with proximity to neighborhood parks, the size of the parks, their cleanliness and the availability of recreational facilities in the parks. Design Cross-sectional. Setting New York City. Subjects 13,102 adults (median age 45 years, 36% male) recruited from 2000–2002. Measures Anthropometric and socio-demographic data from study subjects were linked to Department of Parks & Recreation data on park space, cleanliness, and facilities. Neighborhood level socio-demographic and park proximity metrics were created for half-mile radius circular buffers around each subject’s residence. Proximity to park space was measured as the proportion of the subject’s neighborhood buffer area that was total park space, large park space (a park > 6 acres) and small park space (a park <=6 acres). Analysis Hierarchical linear models were used to determine whether neighborhood park metrics were associated with BMI. Results Higher proximity to large park space was significantly associated with lower BMI (beta = −1.69 95% CI = −2.76, −0.63). Across the population distribution of proximity to large park space, compared to subjects living in neighborhoods at the 10th percentile of the distribution, the covariate adjusted average BMI was estimated to be 0.35 kg/m2 lower for those living in neighborhoods at the 90th percentile. The proportion of neighborhood area that was small park space was not associated with BMI, nor was park cleanliness or the availability of recreational facilities. Conclusions Neighborhood proximity to large park spaces is modestly associated with lower BMI in a diverse urban population. PMID:23448416

  20. Maintaining Accountability for an Ecobehavioral Treatment of One Aspect of Child Neglect: Personal Cleanliness.

    ERIC Educational Resources Information Center

    Rosenfiled-Schlichter, M. D.; And Others

    1983-01-01

    An ecobehavioral intervention was developed in which agencies and services cooperated, circumventing the mother, to improve the personal cleanliness of two severely neglected children. Intervention included contingent allowance, visits, and laundry assistance. (CL)

  1. Comparing visual inspection, aerobic colony counts, and adenosine triphosphate bioluminescence assay for evaluating surface cleanliness at a medical center.

    PubMed

    Huang, Yu-Shan; Chen, Yee-Chun; Chen, Mei-Ling; Cheng, Aristine; Hung, I-Chen; Wang, Jann-Tay; Sheng, Wang-Huei; Chang, Shan-Chwen

    2015-08-01

    Environmental cleaning is essential in reducing microbial colonization and health care-associated infections in hospitals. However, there is no consensus for the standard method to assess hospital cleanliness, and comparisons of newer methodology, such as adenosine triphosphate bioluminescence assay, with the traditional methods are limited. A prospective study was conducted at a medical center between January 2013 and August 2013. In each selected room, 10-12 high-touch surfaces were sampled before and after terminal cleaning. The adequacy of cleaning was evaluated by visual inspection, aerobic colony counts (ACCs), and adenosine triphosphate (ATP) bioluminescence assay. Eighty-five environmental surfaces from 8 rooms were evaluated by all 3 methods. The overall inadequacy defined by visual inspection, ACC, and ATP level was 11.8%, 20.0%, and 50.6% before cleaning and 4.7%, 5.9%, 21.2% after cleaning, respectively. A correlation between the ACC and ATP was found (r = 0.285, P < .001) using log10 values. Using ACCs <2.5 colony forming units/cm(2) as the cutoff for cleanliness, the ATP assay had better sensitivity than visual inspection (63.6% vs 27.3%). The receiver operating characteristics of the ATP assay indicated that the optimal ATP cutoff value was estimated to be 5.57 relative light units/cm(2). ATP bioluminescence assay is a sensitive and rapid tool in evaluating the quality of terminal cleaning. We emphasize the value of using a quantitative method to monitor environmental cleaning at hospitals. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Mechanical Abrasion as a Low Cost Technique for Contamination-Free Sample Acquisition from a Category IVA Clean Platform

    NASA Technical Reports Server (NTRS)

    Dolgin, B.; Yarbrough, C.; Carson, J.; Troy, R.

    2000-01-01

    The proposed Mars Sample Transfer Chain Architecture provides Planetary Protection Officers with clean samples that are required for the eventual release from confinement of the returned Martian samples. At the same time, absolute cleanliness and sterility requirement is not placed of any part of the Lander (including the deep drill), Mars Assent Vehicle (MAV), any part of the Orbiting Sample container (OS), Rover mobility platform, any part of the Minicorer, Robotic arm (including instrument sensors), and most of the caching equipment on the Rover. The removal of the strict requirements in excess of the Category IVa cleanliness (Pathfinder clean) is expected to lead to significant cost savings. The proposed architecture assumes that crosscontamination renders all surfaces in the vicinity of the rover(s) and the lander(s) contaminated. Thus, no accessible surface of Martian rocks and soil is Earth contamination free. As a result of the latter, only subsurface samples (either rock or soil) can be and will be collected for eventual return to Earth. Uncontaminated samples can be collected from a Category IVa clean platform. Both subsurface soil and rock samples can be maintained clean if they are collected by devices that are self-contained and clean and sterile inside only. The top layer of the sample is removed in a manner that does not contaminate the collection tools. Biobarrier (e.g., aluminum foil) covering the moving parts of these devices may be used as the only self removing bio-blanket that is required. The samples never leave the collection tools. The lids are placed on these tools inside the collection device. These single use tools with the lid and the sample inside are brought to Earth in the OS. The lids have to be designed impenetrable to the Earth organisms. The latter is a well established art.

  3. [Environmental geochemical baseline of heavy metals in soils of the Ili river basin and pollution evaluation].

    PubMed

    Zhao, Xin-Ru; Nasier, Telajin; Cheng, Yong-Yi; Zhan, Jiang-Yu; Yang, Jian-Hong

    2014-06-01

    Environmental geochemical baseline models of Cu, Zn, Pb, As, Hg were established by standardized method in the ehernozem, chestnut soil, sierozem and saline soil from the Ili river valley region. The theoretical baseline values were calculated. Baseline factor pollution index evaluation method, environmental background value evaluation method and heavy metal cleanliness evaluation method were used to compare soil pollution degrees. The baseline factor pollution index evaluation showed that As pollution was the most prominent among the four typical types of soils within the river basin, with 7.14%, 9.76%, 7.50% of sampling points in chernozem, chestnut soil and sierozem reached the heavy pollution, respectively. 7.32% of sampling points of chestnut soil reached the permitted heavy metal Pb pollution index in the chestnut soil. The variation extent of As and Pb was the largest, indicating large human disturbance. Environmental background value evaluation showed that As was the main pollution element, followed by Cu, Zn and Pb. Heavy metal cleanliness evaluation showed that Cu, Zn and Pb were better than cleanliness level 2 and Hg was the of cleanliness level 1 in all four types of soils. As showed moderate pollution in sierozem, and it was of cleanliness level 2 or better in chernozem, chestnut soil and saline-alkali soil. Comparing the three evaluation systems, the baseline factor pollution index evaluation more comprehensively reflected the geochemical migration characteristics of elements and the soil formation processes, and the pollution assessment could be specific to the sampling points. The environmental background value evaluation neglected the natural migration of heavy metals and the deposition process in the soil since it was established on the regional background values. The main purpose of the heavy metal cleanliness evaluation was to evaluate the safety degree of soil environment.

  4. Clean Up Your School Custodial Program.

    ERIC Educational Resources Information Center

    Steller, Arthur W.; Pell, Carroll

    1986-01-01

    Administrators can improve their school's custodial program by following steps that increase productivity, reduce costs, and provide long-term benefits of higher cleanliness standards. Administrators should work toward improved building cleanliness by insisting on a school board policy that establishes objectives for the custodial department.…

  5. School Hygiene as a Tool of Modernization: European Culture and Jewish Colonies in Galilee (1882-1939).

    PubMed

    Seltenreich, Yair

    2017-01-01

    During the efforts to modernize the farmers of Jewish colonies in Galilee, both teachers and doctors came to view hygiene less as an agent of health and cleanliness and more as a symbol of physical and mental regeneration. Schools thus emerged as a natural arena for hygieno-pedagogic activities. Doctors' attempts to eradicate malaria or trachoma by associating the concept of hygiene with modern sanitation and outdoor activities were soon followed by pedagogical efforts to endow hygiene with moral values.

  6. Improved latrine cleanliness through behaviour change and changes in quality of latrine construction: a longitudinal intervention study in rural Burundi.

    PubMed

    Mosler, Hans-Joachim; Sonego, Ina Lucia

    2017-10-01

    Latrine cleanliness increased in the intervention group compared to the control group (increase from 21 to 31 % of latrines classified as clean in intervention [N = 198] and decrease from 37 to 27 % in control [N = 91]). Improved habitual latrine cleaning lead to latrines being 3.5 times more likely to improve in observed latrine cleanliness (χ 2  = 16.36, p < .001) and so did improvements in quality of latrine construction, eg households that had installed a lid were 7.39 times more likely to have a cleaner latrine (χ 2  = 4.46, p < .05). Changes in psychosocial factors, namely forgetting, personal norm, satisfaction with cleanliness, explained much of the change in habitual latrine cleaning (adj. r 2  = .46). Behaviour change interventions targeting psychosocial factors and quality of latrine construction seem promising to ensure clean and hygienic latrines.

  7. Bioluminescence ATP Monitoring for the Routine Assessment of Food Contact Surface Cleanliness in a University Canteen

    PubMed Central

    Osimani, Andrea; Garofalo, Cristiana; Clementi, Francesca; Tavoletti, Stefano; Aquilanti, Lucia

    2014-01-01

    ATP bioluminescence monitoring and traditional microbiological analyses (viable counting of total mesophilic aerobes, coliforms and Escherichia coli) were used to evaluate the effectiveness of Sanitation Standard Operating Procedures (SSOP) at a university canteen which uses a HACCP-based approach. To that end, 10 cleaning control points (CPs), including food contact surfaces at risk of contamination from product residues or microbial growth, were analysed during an 8-month monitoring period. Arbitrary acceptability limits were set for both microbial loads and ATP bioluminescence readings. A highly significant correlation (r = 0.99) between the means of ATP bioluminescence readings and the viable counts of total mesophilic aerobes was seen, thus revealing a strong association of these parameters with the level of surface contamination. Among CPs, the raw meat and multi-purpose chopping boards showed the highest criticalities. Although ATP bioluminescence technology cannot substitute traditional microbiological analyses for the determination of microbial load on food contact surfaces, it has proved to be a powerful tool for the real time monitoring of surface cleanliness at mass catering plants, for verify the correct application of SSOP, and hence for their implementation/revision in the case of poor hygiene. PMID:25329534

  8. Bioluminescence ATP monitoring for the routine assessment of food contact surface cleanliness in a university canteen.

    PubMed

    Osimani, Andrea; Garofalo, Cristiana; Clementi, Francesca; Tavoletti, Stefano; Aquilanti, Lucia

    2014-10-17

    ATP bioluminescence monitoring and traditional microbiological analyses (viable counting of total mesophilic aerobes, coliforms and Escherichia coli) were used to evaluate the effectiveness of Sanitation Standard Operating Procedures (SSOP) at a university canteen which uses a HACCP-based approach. To that end, 10 cleaning control points (CPs), including food contact surfaces at risk of contamination from product residues or microbial growth, were analysed during an 8-month monitoring period. Arbitrary acceptability limits were set for both microbial loads and ATP bioluminescence readings. A highly significant correlation (r = 0.99) between the means of ATP bioluminescence readings and the viable counts of total mesophilic aerobes was seen, thus revealing a strong association of these parameters with the level of surface contamination. Among CPs, the raw meat and multi-purpose chopping boards showed the highest criticalities. Although ATP bioluminescence technology cannot substitute traditional microbiological analyses for the determination of microbial load on food contact surfaces, it has proved to be a powerful tool for the real time monitoring of surface cleanliness at mass catering plants, for verify the correct application of SSOP, and hence for their implementation/revision in the case of poor hygiene.

  9. Sensor for the working surface cleanliness definition in vacuum

    NASA Astrophysics Data System (ADS)

    Deulin, E. A.; Mashurov, S. S.; Gatsenko, A. A.

    2016-07-01

    Modern development of nanotechnology as one of the modern science priority directions is impossible to imagine without the use of vacuum systems and technologies. And the better the vacuum (lower the pressure), the “cleaner” we get a surface, which is very important for nanotechnology. Determination of the cleanliness of the surface or the amount of molecular layers of adsorbed gases on the working surface of the products especially in industry, where the cleanliness of the working surface is a key parameter of the technological process and has a significant influence on the output parameters of the final product is the main goal of this work.

  10. Treatment of Childhood Encopresis: Full Cleanliness Training

    ERIC Educational Resources Information Center

    Arnold, Susan; Doleys, Daniel M.

    1975-01-01

    Full Cleanliness Training (a procedure in which the trainee is required to correct the results of inappropriate toileting behavior by cleaning himself and his clothing) was used in combination with positive reinforcement to deal with a trainable retarded 8 year old boy with encopresis and a toilet phobia. (Author/CL)

  11. 49 CFR 174.715 - Cleanliness of transport vehicles after use.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Cleanliness of transport vehicles after use. 174.715 Section 174.715 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY RAIL Detailed Requirements for Class 7 ...

  12. Bibliography: Codes, standards, procedures, specifications and reports relating to contamination control

    NASA Technical Reports Server (NTRS)

    Ledoux, F. N.

    1970-01-01

    The bibliography is arranged in separate sections under headings that include: (1) spacecraft cleanliness, (2) general cleaning, (3) clean room and work stations, (4) contamination, (5) decontamination, (6) manufacturing, (7) miscellaneous, (8) particle count analysis, (9) passivation, (10) packaging, (11) water, and (12) acids and detergents.

  13. Clean Metal Casting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makhlouf M. Makhlouf; Diran Apelian

    The objective of this project is to develop a technology for clean metal processing that is capable of consistently providing a metal cleanliness level that is fit for a given application. The program has five tasks: Development of melt cleanliness assessment technology, development of melt contamination avoidance technology, development of high temperature phase separation technology, establishment of a correlation between the level of melt cleanliness and as cast mechanical properties, and transfer of technology to the industrial sector. Within the context of the first task, WPI has developed a standardized Reduced Pressure Test that has been endorsed by AFS asmore » a recommended practice. In addition, within the context of task1, WPI has developed a melt cleanliness sensor based on the principles of electromagnetic separation. An industrial partner is commercializing the sensor. Within the context of the second task, WPI has developed environmentally friendly fluxes that do not contain fluorine. Within the context of the third task, WPI modeled the process of rotary degassing and verified the model predictions with experimental data. This model may be used to optimize the performance of industrial rotary degassers. Within the context of the fourth task, WPI has correlated the level of melt cleanliness at various foundries, including a sand casting foundry, a permanent mold casting foundry, and a die casting foundry, to the casting process and the resultant mechanical properties. This is useful in tailoring the melt cleansing operations at foundries to the particular casting process and the desired properties of cast components.« less

  14. Inspection Tools

    NASA Astrophysics Data System (ADS)

    1989-01-01

    A "NASA Tech Briefs" article describing an inspection tool and technique known as Optically Stimulated Electron Emission (OSEE) led to the formation of Photo Acoustic Technology, Inc. (PAT). PAT produces sensors and scanning systems which assure surface cleanliness prior to bonding, coating, painting, etc. The company's OP1000 series realtime pre-processing detection capability assures 100 percent surface quality testing. The technique involves brief exposure of the inspection surface to ultraviolet radiation. The energy interacts with the surface layer, causing free electrons to be emitted from the surface to be picked up by the detector. When contamination is present, it interferes with the electron flow in proportion to the thickness of the contaminant layer enabling measurement by system signal output. OP1000 systems operate in conventional atmospheres on all types of material and detect both organic and inorganic contamination.

  15. Towards a better control of optics cleanliness

    NASA Astrophysics Data System (ADS)

    Berlioz, P.

    2017-11-01

    The contamination of optics can considerably degrade the transmission and scattering of spacecraft optics. To prevent efficiently optics from contamination involves introducing since design phase requirements on materials and protections (covers…). Then, integration and test phase demands to implement heavy and stringent means (clean room, specific garment, covers…) and a permanent monitoring by fine contamination measurement of instrument environment and surfaces. Contamination budgets are drawn the project along, first prediction budgets based on analysis and potentially modeling, during design phase, then actual budgets based on contamination measurement during integration and test phase. Finally, the risk still exists to have to clean optics because of hazardous contamination, furthermore to dismount them. The cleanliness engineering set at ASTRIUM Toulouse is presented here, including the contamination monitoring via witness samples measured by IR spectrometry and via counters. ASTRIUM is presently focusing attention on no contact cleaning like the promising UV-ozone process.

  16. Associations between active trachoma and community intervention with Antibiotics, Facial cleanliness, and Environmental improvement (A,F,E).

    PubMed

    Ngondi, Jeremiah; Matthews, Fiona; Reacher, Mark; Baba, Samson; Brayne, Carol; Emerson, Paul

    2008-04-30

    Surgery, Antibiotics, Facial cleanliness and Environmental improvement (SAFE) are advocated by the World Health Organization (WHO) for trachoma control. However, few studies have evaluated the complete SAFE strategy, and of these, none have investigated the associations of Antibiotics, Facial cleanliness, and Environmental improvement (A,F,E) interventions and active trachoma. We aimed to investigate associations between active trachoma and A,F,E interventions in communities in Southern Sudan. Surveys were undertaken in four districts after 3 years of implementation of the SAFE strategy. Children aged 1-9 years were examined for trachoma and uptake of SAFE assessed through interviews and observations. Using ordinal logistic regression, associations between signs of active trachoma and A,F,E interventions were explored. Trachomatous inflammation-intense (TI) was considered more severe than trachomatous inflammation-follicular (TF). A total of 1,712 children from 25 clusters (villages) were included in the analysis. Overall uptake of A,F,E interventions was: 53.0% of the eligible children had received at least one treatment with azithromycin; 62.4% children had a clean face on examination; 72.5% households reported washing faces of children two or more times a day; 73.1% households had received health education; 44.4% of households had water accessible within 30 minutes; and 6.3% households had pit latrines. Adjusting for age, sex, and district baseline prevalence of active trachoma, factors independently associated with reduced odds of a more severe active trachoma sign were: receiving three treatments with azithromycin (odds ratio [OR] = 0.1; 95% confidence interval [CI] 0.0-0.4); clean face (OR = 0.3; 95% CI 0.2-0.4); washing faces of children three or more times daily (OR = 0.4; 95% CI 0.3-0.7); and presence and use of a pit latrine in the household (OR = 0.4; 95% CI 0.2-0.9). Analysis of associations between the A,F,E components of the SAFE strategy and active trachoma showed independent protective effects against active trachoma of mass systemic azithromycin treatment, facial cleanliness, face washing, and use of pit latrines in the household. This strongly argues for continued use of all the components of the SAFE strategy together.

  17. Food safety hazards lurk in the kitchens of young adults.

    PubMed

    Byrd-Bredbenner, Carol; Maurer, Jaclyn; Wheatley, Virginia; Cottone, Ellen; Clancy, Michele

    2007-04-01

    Food mishandling in home kitchens likely causes a significant amount of foodborne disease; however, little is known about the food safety hazards lurking in home kitchens. The purposes of this study were to audit the kitchens of young adults with education beyond high school to identify food safety problems and develop recommendations for education efforts. Researchers developed a criterion-referenced home kitchen observation instrument to assess compliance of home food storage and rotation practices (e.g., temperature), sanitation and chemical storage, and general kitchen condition (e.g., infestation) with recommended practices. The instrument contained seven scales: Kitchen Cleanliness (eight items), Appliance Cleanliness (three items), Cleaning Supplies Availability (eight items), Temperatures (Food Thermometer Access & Refrigerator/Freezer Temperatures) (five items), Cold Food Storage (seven items), Dry Food Storage (eight items), and Poisons Storage (two items). Descriptive statistics were conducted to describe the study population, as a whole, and by gender. A total of 154 young adults (mean age, 20.7+/- 1.3 SD) enrolled in a northeastern university participated. Participants scored 70% or higher on Poisons Storage, Dry Food Storage, Kitchen Cleanliness, and Cleaning Supplies Availability scales but less than 60% on the Appliance Cleanliness and Cold Food Storage scales. Performance was lowest on the Temperatures scale. Females scored significantly higher than males on the Kitchen Cleanliness and Cleaning Supply Availability scales. Average refrigerator and freezer temperatures were higher than recommendations. Food safety education targeted at this young adult population needs to evolve into focused messages pertaining to the key food safety violations in this population.

  18. Effect of Cleanliness on Hydrogen Tolerance in High-Strength Steel

    DTIC Science & Technology

    2014-04-01

    in High-Strength Steel 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) Scott M. Grendahl, Franklyn Kellogg ,* and...Effect of Cleanliness on Hydrogen Tolerance in High-Strength Steel by Scott M. Grendahl, Franklyn Kellogg , and Hoang Nguyen ARL-TR...Directorate, ARL Franklyn Kellogg and Hoang Nguyen Bowhead Technical Services Approved for public

  19. An OSEE Based Portable Surface Contamination Monitor

    NASA Technical Reports Server (NTRS)

    Perey, Daniel F.

    1997-01-01

    Many industrial and aerospace processes involving the joining of materials, require sufficient surface cleanliness to insure proper bonding. Processes as diverse as painting, welding, or the soldering of electronic circuits will be compromised if prior inspection and removal of surface contaminants is inadequate. As process requirements become more stringent and the number of different materials and identified contaminants increases, various instruments and techniques have been developed for improved inspection. One such technique based on the principle of Optically Stimulated Electron Emission (OSEE) has been explored for a number of years as a tool for surface contamination monitoring. Some of the benefits of OSEE are: it's non-contacting; requires little operator training; and has very high contamination sensitivity. This paper describes the development of a portable OSEE based surface contamination monitor. The instrument is suitable for both hand-held and robotic inspections with either manual or automated control of instrument operation. In addition, instrument output data is visually displayed to the operator and may be output to an external computer for archiving or analysis.

  20. The enerMENA meteorological network - Solar radiation measurements in the MENA region

    NASA Astrophysics Data System (ADS)

    Schüler, D.; Wilbert, S.; Geuder, N.; Affolter, R.; Wolfertstetter, F.; Prahl, C.; Röger, M.; Schroedter-Homscheidt, M.; Abdellatif, G.; Guizani, A. Allah; Balghouthi, M.; Khalil, A.; Mezrhab, A.; Al-Salaymeh, A.; Yassaa, N.; Chellali, F.; Draou, D.; Blanc, P.; Dubranna, J.; Sabry, O. M. K.

    2016-05-01

    For solar resource assessment of solar power plants and adjustment of satellite data, high accuracy measurement data of irradiance and ancillary meteorological data is needed. For the MENA region (Middle East and Northern Africa), which is of high importance for concentrating solar power applications, so far merely 2 publicly available ground measurement stations existed (BSRN network). This gap has been filled by ten stations in Morocco, Algeria, Tunisia, Egypt and Jordan. In this publication the data quality is analyzed by evaluating data completeness and the cleanliness of irradiance sensors in comparison for all of the stations. The pyrheliometers have an average cleanliness of 99.2 % for week-daily cleaning. This is a 5 times higher effort than for Rotating Shadowband Irradiometer (RSI) stations which even have a slightly higher average cleanliness of 99.3 % for weekly cleaning. Furthermore, RSI stations show a data completeness of 99.4 % compared to 93.6 % at the stations equipped with thermal sensors. The results of this analysis are used to derive conclusions concerning instrument choice and are hence also applicable to other solar radiation measurements outside the enerMENA network. It turns out that RSIs are the more reliable and robust choice in cases of high soiling, rare station visits for cleaning and maintenance, as usual in desert sites. Furthermore, annual direct normal and global horizontal irradiation as well as average meteorological parameters are calculated for all of the stations.

  1. A comparison of residual smear layer and erosion following different endodontic irrigation protocols tested under clinical and laboratory conditions.

    PubMed

    Cehreli, Zafer C; Uyanik, M Ozgur; Nagas, Emre; Tuncel, Behram; Er, Nuray; Comert, Fugen Dagli

    2013-09-01

    To compare the smear layer removal efficacy and erosive effects of different irrigation protocols under clinical and laboratory conditions. Mandibular third molars (n = 32) of 30-45 year-old patients were instrumented with rotary files and were randomly assigned to one of the following groups for final irrigation: (1) 5.25% NaOCl; (2) 17% EDTA; and (3) BioPure MTAD. Thereafter, the teeth were immediately extracted and processed for micromorphological investigation. In vitro specimen pairs were prepared by repeating the clinical experiments on freshly-extracted mandibular third molars. To compare open and closed systems, laboratory experiments were repeated on 32 additional teeth with enlarged apical foramen. The cleanliness of the root canals and the extent of erosion were assessed by environmental scanning electron microscopy. Specimens prepared under clinical and laboratory conditions had similar cleanliness and erosion scores (p > 0.05). Under both conditions, the tested solutions were more effective in removing the smear layer in the coronal and middle regions than in the apical one. Comparison of closed and open systems showed similar levels of cleanliness and erosion in all regions (p > 0.05), with the exception of 17% EDTA showing significantly higher levels of cleanliness and erosion in the apical third of open-end specimens. Based on clinical correlates of in vitro root canal cleanliness and erosion, laboratory testing of root canal irrigants on extracted teeth with closed apices can serve as a reliable method to simulate the clinical condition. EDTA was the most effective final irrigation solution in removing the smear layer at the expense of yielding the greatest erosive effect.

  2. Smoking, tooth brushing and oral cleanliness among 15-year-olds in Tehran, Iran.

    PubMed

    Yazdani, Reza; Vehkalahti, Miira M; Nouri, Mahtab; Murtomaa, Heikki

    2008-01-01

    To assess smoking, tooth brushing and oral cleanliness and their relationships among 15-year-olds in Tehran, Iran. A cross-sectional study based on World Health Organization criteria and the methods of the Second International Collaborative Study was carried out in autumn 2004 among 15-year-olds (n=502) in Tehran. Data were based on a self-administered questionnaire and a clinical dental examination. Smokers comprised 5% of the boys and 2% of the girls (p = 0.02). Smoking was more common among students of less-educated parents (50% vs. 30%, p < 0.05). Of all students, 26% reported twice-daily tooth brushing; those of higher socio-economic backgrounds and girls did so more frequently. Of the smokers, 11% reported no tooth brushing compared to 6% of the non-smokers. Oral cleanliness was good for 13%, moderate for 32%, and poor for 55%; the rates associated positively with female gender (p = 0.002), having higher-educated parents (p = 0.03), and reporting a higher frequency of tooth brushing (p < 0.001). Those students reporting twice-daily tooth brushing had less dental plaque and gingival bleeding (p < or = 0.01) on both anterior and posterior teeth. In multivariable analyses, the best predictors for a good level of oral cleanliness were female gender (OR = 2.0) or twice-daily tooth brushing (OR = 1.7). Oral cleanliness and tooth brushing among 15-year-olds were at poor levels, particularly among boys. Such poor levels call for intensive attempts to enhance rates of twice-daily tooth brushing and to improve its quality. For this age group, anti-smoking purposes should be combined into school-based oral health promotion programmes as well.

  3. Percent area coverage through image analysis

    NASA Astrophysics Data System (ADS)

    Wong, Chung M.; Hong, Sung M.; Liu, De-Ling

    2016-09-01

    The notion of percent area coverage (PAC) has been used to characterize surface cleanliness levels in the spacecraft contamination control community. Due to the lack of detailed particle data, PAC has been conventionally calculated by multiplying the particle surface density in predetermined particle size bins by a set of coefficients per MIL-STD-1246C. In deriving the set of coefficients, the surface particle size distribution is assumed to follow a log-normal relation between particle density and particle size, while the cross-sectional area function is given as a combination of regular geometric shapes. For particles with irregular shapes, the cross-sectional area function cannot describe the true particle area and, therefore, may introduce error in the PAC calculation. Other errors may also be introduced by using the lognormal surface particle size distribution function that highly depends on the environmental cleanliness and cleaning process. In this paper, we present PAC measurements from silicon witness wafers that collected fallouts from a fabric material after vibration testing. PAC calculations were performed through analysis of microscope images and compare them to values derived through the MIL-STD-1246C method. Our results showed that the MIL-STD-1246C method does provide a reasonable upper bound to the PAC values determined through image analysis, in particular for PAC values below 0.1.

  4. Developing the Cleanliness Requirements for an Organic-detection Instrument MOMA-MS

    NASA Technical Reports Server (NTRS)

    Perry, Radford; Canham, John; Lalime, Erin

    2015-01-01

    The cleanliness requirements for an organic-detection instrument, like the Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS), on a Planetary Protection Class IVb mission can be extremely stringent. These include surface molecular and particulate, outgassing, and bioburden. The prime contractor for the European Space Agencys ExoMars 2018 project, Thales Alenia Space Italy, provided requirements based on a standard, conservative approach of defining limits which yielded levels that are unverifiable by standard cleanliness verification methods. Additionally, the conservative method for determining contamination surface area uses underestimation while conservative bioburden surface area relies on overestimation, which results in inconsistencies for the normalized reporting. This presentation will provide a survey of the challenge to define requirements that can be reasonably verified and still remain appropriate to the core science of the ExoMars mission.

  5. Studying the Use of Photocatalytic Coatings to Increase Building/Structure Sustainability and Cleanliness at NASA Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Underwood, Lauren

    2013-01-01

    TiO2 coated surfaces demonstrated both visually through photographic representation, and quantitatively, through reflectance measurements that they improved upon the current state of cleanliness upon the surfaces that they were applied to. TiO2 has the potential to both maintain and increase building s sustainability and the overall appearance of cleanliness TiO2 coated slides degraded soot under UV light compared to soot samples on plain uncoated slides under the same conditions Degradation of soot by photocatalysis was far more apparent than degradation of soot by UV light alone This demonstration provides the foundation for a laboratory model that could be used to simulate real world applications for photocatalytic materials Additional research is required to better understand the full potential of TiO2

  6. Washing away your sins in the brain: physical cleaning and priming of cleaning recruit different brain networks after moral threat

    PubMed Central

    Tang, Honghong; Lu, Xiaping; Su, Rui; Liang, Zilu; Mai, Xiaoqin

    2017-01-01

    Abstract The association between moral purity and physical cleanliness has been widely discussed recently. Studies found that moral threat initiates the need of physical cleanliness, but actual physical cleaning and priming of cleaning have inconsistent effects on subsequent attitudes and behaviors. Here, we used resting-state functional magnetic resonance imaging to explore the underlying neural mechanism of actual physical cleaning and priming of cleaning. After recalling moral transgression with strong feelings of guilt and shame, participants either actually cleaned their faces with a wipe or were primed with cleanliness through viewing its pictures. Results showed that actual physical cleaning reduced the spontaneous brain activities in the right insula and MPFC, regions that involved in embodied moral emotion processing, while priming of cleaning decreased activities in the right superior frontal gyrus and middle frontal gyrus, regions that participated in executive control processing. Additionally, actual physical cleaning also changed functional connectivity between insula/MPFC and emotion related regions, whereas priming of cleaning modified connectivity within both moral and sensorimotor areas. These findings revealed that actual physical cleaning and priming of cleaning led to changes in different brain regions and networks, providing neural evidence for the inconsistent effects of cleanliness on subsequent attitudes and behaviors. PMID:28338887

  7. Washing away your sins in the brain: physical cleaning and priming of cleaning recruit different brain networks after moral threat.

    PubMed

    Tang, Honghong; Lu, Xiaping; Su, Rui; Liang, Zilu; Mai, Xiaoqin; Liu, Chao

    2017-07-01

    The association between moral purity and physical cleanliness has been widely discussed recently. Studies found that moral threat initiates the need of physical cleanliness, but actual physical cleaning and priming of cleaning have inconsistent effects on subsequent attitudes and behaviors. Here, we used resting-state functional magnetic resonance imaging to explore the underlying neural mechanism of actual physical cleaning and priming of cleaning. After recalling moral transgression with strong feelings of guilt and shame, participants either actually cleaned their faces with a wipe or were primed with cleanliness through viewing its pictures. Results showed that actual physical cleaning reduced the spontaneous brain activities in the right insula and MPFC, regions that involved in embodied moral emotion processing, while priming of cleaning decreased activities in the right superior frontal gyrus and middle frontal gyrus, regions that participated in executive control processing. Additionally, actual physical cleaning also changed functional connectivity between insula/MPFC and emotion related regions, whereas priming of cleaning modified connectivity within both moral and sensorimotor areas. These findings revealed that actual physical cleaning and priming of cleaning led to changes in different brain regions and networks, providing neural evidence for the inconsistent effects of cleanliness on subsequent attitudes and behaviors. © The Author (2017). Published by Oxford University Press.

  8. Investigation of Cleanliness Verification Techniques for Rocket Engine Hardware

    NASA Technical Reports Server (NTRS)

    Fritzemeier, Marilyn L.; Skowronski, Raymund P.

    1994-01-01

    Oxidizer propellant systems for liquid-fueled rocket engines must meet stringent cleanliness requirements for particulate and nonvolatile residue. These requirements were established to limit residual contaminants which could block small orifices or ignite in the oxidizer system during engine operation. Limiting organic residues in high pressure oxygen systems, such as in the Space Shuttle Main Engine (SSME), is particularly important. The current method of cleanliness verification for the SSME uses an organic solvent flush of the critical hardware surfaces. The solvent is filtered and analyzed for particulate matter followed by gravimetric determination of the nonvolatile residue (NVR) content of the filtered solvent. The organic solvents currently specified for use (1, 1, 1-trichloroethane and CFC-113) are ozone-depleting chemicals slated for elimination by December 1995. A test program is in progress to evaluate alternative methods for cleanliness verification that do not require the use of ozone-depleting chemicals and that minimize or eliminate the use of solvents regulated as hazardous air pollutants or smog precursors. Initial results from the laboratory test program to evaluate aqueous-based methods and organic solvent flush methods for NVR verification are provided and compared with results obtained using the current method. Evaluation of the alternative methods was conducted using a range of contaminants encountered in the manufacture of rocket engine hardware.

  9. Supersonic Gas-Liquid Cleaning System

    NASA Technical Reports Server (NTRS)

    Kinney, Frank

    1996-01-01

    The Supersonic Gas-Liquid Cleaning System Research Project consisted mainly of a feasibility study, including theoretical and engineering analysis, of a proof-of-concept prototype of this particular cleaning system developed by NASA-KSC. The cleaning system utilizes gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the device to be cleaned. The cleaning fluid being accelerated to these high velocities may consist of any solvent or liquid, including water. Compressed air or any inert gas is used to provide the conveying medium for the liquid, as well as substantially reduce the total amount of liquid needed to perform adequate surface cleaning and cleanliness verification. This type of aqueous cleaning system is considered to be an excellent way of conducting cleaning and cleanliness verification operations as replacements for the use of CFC 113 which must be discontinued by 1995. To utilize this particular cleaning system in various cleaning applications for both the Space Program and the commercial market, it is essential that the cleaning system, especially the supersonic nozzle, be characterized for such applications. This characterization consisted of performing theoretical and engineering analysis, identifying desirable modifications/extensions to the basic concept, evaluating effects of variations in operating parameters, and optimizing hardware design for specific applications.

  10. A quantitative and qualitative analysis of ultrasonic versus sonic endodontic systems on canal cleanliness and obturation.

    PubMed

    Kanter, Valerie; Weldon, Emily; Nair, Uma; Varella, Claudio; Kanter, Keith; Anusavice, Kenneth; Pileggi, Roberta

    2011-12-01

    The purpose of this study was to compare 2 irrigation techniques by evaluating canal cleanliness and obturation of lateral/accessory canals. Seventy-five extracted canines were instrumented to a size #40/0.06 taper. The EndoActivator (EA) was compared with an ultrasonic unit for final irrigation. Each unit was used for 1 minute each with 6.15% NaOCl and 17% EDTA. A control group received syringe irrigation. Thirty teeth were sectioned and evaluated for debris removal and open dentinal tubules at 3/5 mm from the apical foramen with a scanning electron microscope. Forty-five teeth were examined for obturation of lateral canals. The EA was significantly better in removing debris at all levels when compared with other treatment groups (P < .05) and resulted in obturation of significantly more numbers of lateral canals (P < .01.) The EA provided better obturation of lateral and accessory canals and resulted in less remaining debris. Copyright © 2011 Mosby, Inc. All rights reserved.

  11. Surface Plasmon Resonance Based Sensitive Immunosensor for Benzaldehyde Detection

    NASA Astrophysics Data System (ADS)

    Onodera, Takeshi; Shimizu, Takuzo; Miura, Norio; Matsumoto, Kiyoshi; Toko, Kiyoshi

    Fragrant compounds used to add flavor to beverages remain in the manufacturing line after the beverage manufacturing process. Line cleanliness before the next manufacturing cycle is difficult to estimate by sensory analysis, making excessive washing necessary. A new measurement system to determine line cleanliness is desired. In this study, we attempted to detect benzaldehyde (Bz) using an anti-Bz monoclonal antibody (Bz-Ab) and a surface plasmon resonance (SPR) sensor. We fabricated two types of sensor chips using self-assembled monolayers (SAMs) and investigated which sensor surface exhibited higher sensitivity. In addition, anti-Bz antibody conjugated with horseradish peroxidase (HRP-Bz-Ab) was used to enhance the SPR signal. A detection limit of ca. 9ng/mL (ppb) was achieved using an immobilized 4-carboxybenzaldehyde sensor surface using SAMs containing ethylene glycol. When the HRP-Bz-Ab concentration was reduced to 30ng/mL, a detection limit of ca. 4ng/mL (ppb) was achieved for Bz.

  12. Magnetic cleanliness verification approach on tethered satellite

    NASA Technical Reports Server (NTRS)

    Messidoro, Piero; Braghin, Massimo; Grande, Maurizio

    1990-01-01

    Magnetic cleanliness testing was performed on the Tethered Satellite as the last step of an articulated verification campaign aimed at demonstrating the capability of the satellite to support its TEMAG (TEthered MAgnetometer) experiment. Tests at unit level and analytical predictions/correlations using a dedicated mathematical model (GANEW program) are also part of the verification activities. Details of the tests are presented, and the results of the verification are described together with recommendations for later programs.

  13. Evidence Points To 'Gaming' At Hospitals Subject To National Health Service Cleanliness Inspections.

    PubMed

    Toffolutti, Veronica; McKee, Martin; Stuckler, David

    2017-02-01

    Inspections are a key way to monitor and ensure quality of care and maintain high standards in the National Health Service (NHS) in England. Yet there is a perception that inspections can be gamed. This can happen, for example, when staff members know that an inspection will soon take place. Using data for 205 NHS hospitals for the period 2011-14, we tested whether patients' perceptions of cleanliness increased during periods when inspections occurred. Our results show that during the period within two months of an inspection, there was a significant elevation (2.5-11.0 percentage points) in the share of patients who reported "excellent" cleanliness. This association was consistent even after adjustment for secular time trends. The association was concentrated in hospitals that outsourced cleaning services and was not detected in those that used NHS cleaning services. Project HOPE—The People-to-People Health Foundation, Inc.

  14. Environmental monitoring of the orbiter payload bay and Orbiter Processing Facilities

    NASA Technical Reports Server (NTRS)

    Bartelson, D. W.; Johnson, A. M.

    1985-01-01

    Contamination control in the Orbiter Processing Facility (OPF) is studied. The clean level required in the OPF is generally clean, which means no residue, dirt, debris, or other extraneous contamination; various methods of maintaining this level of cleanliness are described. The monitoring and controlling of the temperature, relative humidity, and air quality in the OPF are examined. Additional modifications to the OPF to improve contamination control are discussed. The methods used to maintain the payload changeout room at a level of visually clean, no particulates are to be detected by the unaided eye, are described. The payload bay (PLB) must sustain the cleanliness level required for the specific Orbiter's mission; the three levels of clean are defined as: (1) standard, (2) sensitive, and (3) high sensitive. The cleaning and inspection verification required to achieve the desired cleanliness level on a variety of PLB surface types are examined.

  15. Influence of the RF electrode cleanliness on plasma characteristics and dust-particle generation in methane dusty plasmas

    NASA Astrophysics Data System (ADS)

    Géraud-Grenier, I.; Desdions, W.; Faubert, F.; Mikikian, M.; Massereau-Guilbaud, V.

    2018-01-01

    The methane decomposition in a planar RF discharge (13.56 MHz) leads both to a dust-particle generation in the plasma bulk and to a coating growth on the electrodes. Growing dust-particles fall onto the grounded electrode when they are too heavy. Thus, at the end of the experiment, the grounded electrode is covered by a coating and by fallen dust-particles. During the dust-particle growth, the negative DC self-bias voltage (VDC) increases because fewer electrons reach the RF electrode, leading to a more resistive plasma and to changes in the plasma chemical composition. In this paper, the cleanliness influence of the RF electrode on the dust-particle growth, on the plasma characteristics and composition is investigated. A cleanliness electrode is an electrode without coating and dust-particles on its surface at the beginning of the experiment.

  16. Earth Observing System/Meteorological Satellite (EOS/METSAT). Advanced Microwave Sounding Unit-A (AMSU-A) Contamination Control Plan

    NASA Technical Reports Server (NTRS)

    Fay, M.

    1998-01-01

    This Contamination Control Plan is submitted in response the Contract Document requirements List (CDRL) 007 under contract NAS5-32314 for the Earth Observing System (EOS) Advanced Microwave Sounding Unit A (AMSU-A). In response to the CDRL instructions, this document defines the level of cleanliness and methods/procedures to be followed to achieve adequate cleanliness/contamination control, and defines the required approach to maintain cleanliness/contamination control through shipping, observatory integration, test, and flight. This plan is also applicable to the Meteorological Satellite (METSAT) except where requirements are identified as EOS-specific. This plan is based on two key factors: a. The EOS/METSAT AMSU-A Instruments are not highly contamination sensitive. b. Potential contamination of other EOS Instruments is a key concern as addressed in Section 9/0 of the Performance Assurance Requirements for EOS/METSAT Integrated Programs AMSU-A Instrument (MR) (NASA Specification S-480-79).

  17. A short period of breastfeeding in infancy, excessive house cleaning, absence of older sibling, and passive smoking are related to more severe atopic dermatitis in children.

    PubMed

    Fotopoulou, Maria; Iordanidou, Maria; Vasileiou, Eleni; Trypsianis, Grigorios; Chatzimichael, Athanasios; Paraskakis, Emmanouil

    2018-02-01

    Atopic dermatitis (AD) is one of the most common, chronic or chronically relapsing inflammatory skin diseases that affect children. Multiple genetic and environmental factors appear to regulate the pathogenesis of AD. Our aim was to investigate the possible association between family, social, dieting, atopic and environmental factors and the severity of AD evaluated by SCORAD scores in children. The study group included 100 children with AD who attended a paediatric dermatology outpatient clinic with a median age of 18.5 months. The diagnosis of AD was established on the basis of the clinical criteria according to the American Dermatology Society, while the SCORAD score was used to evaluate disease severity. Multivariate linear regression analysis disclosed that excessive cleanliness (p<0.001), RAST level greater than 0.7 KU/l (p<0.001), breastfeeding for less than two months (p = 0.001), and the absence of an older sibling (p = 0.049) were statistically significant independent determinants for high SCORAD scores. Multivariate logistic regression analysis showed that excessive cleanliness (p<0.001) was the strongest independent risk factor for severe AD (SCORAD>36) (aOR: 59.4; 95% CI: 10.9-322.6). RAST level greater than 0.7 KU/l (aOR: 7.9; 95% CI: 1.5-41.0; p = 0.014) and severe passive smoking (aOR: 4.6; 95% CI: 1.0-22.1; p = 0.050) also showed a significant independent, but clearly weaker, association with severe AD. A short duration of breastfeeding, absence of older siblings, parental passive smoking, food allergens along with aeroallergens, and excessive cleanliness should be considered as negative prognostic factors, leading to a higher SCORAD score in children with AD.

  18. Protocol for collecting eDNA samples from streams [Version 2.3

    Treesearch

    K. J. Carim; T. Wilcox; M. K. Young; K. S. McKelvey; M. K. Schwartz

    2015-01-01

    Throughout the 2014 field season, we had over two dozen biologist throughout the western US collect over 300 samples for eDNA analysis with paired controls. Control samples were collected by filtering 0.5 L of distilled water. No samples had any evidence of field contamination. This method of sampling verifies the cleanliness of the field equipment, as well as the...

  19. Hubble Space Telescope servicing mission scientific instrument protective enclosure design requirements and contamination controls

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.; Hughes, David W.; Hedgeland, Randy J.; Chivatero, Craig J.; Studer, Robert J.; Kostos, Peter J.

    1994-01-01

    The Scientific Instrument Protective Enclosures were designed for the Hubble Space Telescope Servicing Missions to provide a beginning environment to a Scientific Instrument during ground and on orbit activities. The Scientific Instruments required very stringent surface cleanliness and molecular outgassing levels to maintain ultraviolet performance. Data from the First Servicing Mission verified that both the Scientific Instruments and Scientific Instrument Protective Enclosures met surface cleanliness level requirements during ground and on-orbit activities.

  20. Comparing the Bioburden Measured by Adenosine Triphosphate (ATP) Luminescence Technology to Contact Plate-Based Microbiologic Sampling to Assess the Cleanliness of the Patient Care Environment.

    PubMed

    Salsgiver, Elizabeth; Bernstein, Daniel; Simon, Matthew S; Greendyke, William; Jia, Haomiao; Robertson, Amy; Salter, Selma; Schuetz, Audrey N; Saiman, Lisa; Furuya, E Yoko; Calfee, David P

    2018-05-01

    The correlation between ATP concentration and bacterial burden in the patient care environment was assessed. These findings suggest that a correlation exists between ATP concentration and bacterial burden, and they generally support ATP technology manufacturer-recommended cutoff values. Despite relatively modest discriminative ability, this technology may serve as a useful proxy for cleanliness.Infect Control Hosp Epidemiol 2018;39:622-624.

  1. An effective intervention to improve the cleanliness of medical lead clothes in an orthopedic specialized hospital.

    PubMed

    Chen, Lu; Xu, YingJun; Zhang, Fengxia; Yang, Qingfeng; Yuan, Juxiang

    2016-11-01

    Dirty medical lead clothes, contaminated with blood or other infected material, may carry ongoing bioburden, which increase the risk of hospital-acquired infection. In this study, we investigated medical lead clothes contamination levels and assessed the effectiveness of the intervention that was constructed to improve the cleanliness of lead clothes. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Evaluation of two methods for monitoring surface cleanliness-ATP bioluminescence and traditional hygiene swabbing.

    PubMed

    Davidson, C A; Griffith, C J; Peters, A C; Fielding, L M

    1999-01-01

    The minimum bacterial detection limits and operator reproducibility of the Biotrace Clean-Tracetrade mark Rapid Cleanliness Test and traditional hygiene swabbing were determined. Areas (100 cm2) of food grade stainless steel were separately inoculated with known levels of Staphylococcus aureus (NCTC 6571) and Escherichia coli (ATCC 25922). Surfaces were sampled either immediately after inoculation while still wet, or after 60 min when completely dry. For both organisms the minimum detection limit of the ATP Clean-Tracetrade mark Rapid Cleanliness Test was 10(4) cfu/100 cm2 (p < 0.05) and was the same for wet and dry surfaces. Both organism type and surface status (i.e. wet or dry) influenced the minimum detection limits of hygiene swabbing, which ranged from 10(2) cfu/100 cm2 to >10(7) cfu/100 cm2. Hygiene swabbing percentage recovery rates for both organisms were less than 0.1% for dried surfaces but ranged from 0.33% to 8.8% for wet surfaces. When assessed by six technically qualified operators, the Biotrace Clean-Tracetrade mark Rapid Cleanliness Test gave superior reproducibility for both clean and inoculated surfaces, giving mean coefficients of variation of 24% and 32%, respectively. Hygiene swabbing of inoculated surfaces gave a mean CV of 130%. The results are discussed in the context of hygiene monitoring within the food industry. Copyright 1999 John Wiley & Sons, Ltd.

  3. Factors affecting quality of social interaction park in Jakarta

    NASA Astrophysics Data System (ADS)

    Mangunsong, N. I.

    2018-01-01

    The existence of social interactions park in Jakarta is an oasis in the middle of a concrete jungle. Parks is a response to the need for open space as a place of recreation and community interaction. Often the social interaction parks built by the government does not function as expected, but other functions such as a place to sell, trash, unsafe so be rarely visited by visitors. The purpose of this study was to analyze the factors that affect the quality of social interaction parks in Jakarta by conducting descriptive analysis and correlation analysis of the variables assessment. The results of the analysis can give an idea of social interactions park based on community needs and propose the development of social interactioncity park. The object of study are 25 social interaction parks in 5 municipalities of Jakarta. The method used is descriptive analysis method, correlation analysis using SPSS 19 and using crosstab, chi-square tests. The variables are 5 aspects of Design, Plants composition: Selection type of plant (D); the beauty and harmony (Ind); Maintenance and fertility (P); Cleanliness and Environmental Health (BS); Specificity (Drainage, Multi Function garden, Means, Concern/Mutual cooperation, in dense settlements) (K). The results of analysis show that beauty is the most significant correlation with the value of the park followed by specificity, cleanliness and maintenance. Design was not the most significant variable affecting the quality of the park. The results of this study can be used by the Department of Parks and Cemeteries as input in managing park existing or to be developed and to improve the quality of social interaction park in Jakarta.

  4. A Portable Surface Contamination Monitor Based on the Principle of Optically Stimulated Electron Emission (OSEE)

    NASA Technical Reports Server (NTRS)

    Perey, D. F.

    1996-01-01

    Many industrial and aerospace processes involving the joining of materials, require sufficient surface cleanliness to insure proper bonding. Processes as diverse as painting, welding, or the soldering of electronic circuits will be compromised if prior inspection and removal of surface contaminants is inadequate. As process requirements become more stringent and the number of different materials and identified contaminants increases, various instruments and techniques have been developed for improved inspection. One such technique, based on the principle of Optically Stimulated Electron Emission (OSEE), has been explored for a number of years as a tool for surface contamination monitoring. Some of the benefits of OSEE are: it is non-contacting; requires little operator training; and has very high contamination sensitivity. This paper describes the development of a portable OSEE based surface contamination monitor. The instrument is suitable for both hand-held and robotic inspections with either manual or automated control of instrument operation. In addition, instrument output data is visually displayed to the operator and may be sent to an external computer for archiving or analysis.

  5. Cleanliness verification process at Martin Marietta Astronautics

    NASA Astrophysics Data System (ADS)

    King, Elizabeth A.; Giordano, Thomas J.

    1994-06-01

    The Montreal Protocol and the 1990 Clean Air Act Amendments mandate CFC-113, other chlorinated fluorocarbons (CFC's) and 1,1,1-Trichloroethane (TCA) be banned from production after December 31, 1995. In response to increasing pressures, the Air Force has formulated policy that prohibits purchase of these solvents for Air Force use after April 1, 1994. In response to the Air Force policy, Martin Marietta Astronautics is in the process of eliminating all CFC's and TCA from use at the Engineering Propulsion Laboratory (EPL), located on Air Force property PJKS. Gross and precision cleaning operations are currently performed on spacecraft components at EPL. The final step of the operation is a rinse with a solvent, typically CFC-113. This solvent is then analyzed for nonvolatile residue (NVR), particle count and total filterable solids (TFS) to determine cleanliness of the parts. The CFC-113 used in this process must be replaced in response to the above policies. Martin Marietta Astronautics, under contract to the Air Force, is currently evaluating and testing alternatives for a cleanliness verification solvent. Completion of test is scheduled for May, 1994. Evaluation of the alternative solvents follows a three step approach. This first is initial testing of solvents picked from literature searches and analysis. The second step is detailed testing of the top candidates from the initial test phase. The final step is implementation and validation of the chosen alternative(s). Testing will include contaminant removal, nonvolatile residue, material compatibility and propellant compatibility. Typical materials and contaminants will be tested with a wide range of solvents. Final results of the three steps will be presented as well as the implementation plan for solvent replacement.

  6. Comparison between high concentration EDTA (24%) and low concentration EDTA (3%) with surfactant upon removal of smear layer after rotary instrumentation: a SEM study.

    PubMed

    Daghustani, Mohsen; Alhammadi, Ahmad; Merdad, Khalid; Ohlin, Johan; Erhardt, Fredrik; Ahlquist, Michael

    2011-01-01

    This in vitro study compare cleanliness of tooth canal walls regarding smear layer after final treatment with 24% ethylenediaminetetraaceticacid (EDTA) and 3% EDTA with or without surfactant. Sixty extracted teeth, randomly distributed into four groups, were prepared using ProFile instruments (DENTSPLY, Maillefer, Ballaigues, Switzerland), and subjected to different final irrigation solutions: group A, 24% EDTA; group B, 3% EDTA with surfactant; group C (positive control), 3% EDTA; and group D (negative control), 0.5% sodium hypochlorite. Roots were sectioned, examined and evaluated under scanning electron microscope; microphotographs were taken for the coronal, middle and apical third of each specimen. Statistical analysis showed no difference regarding presence of smear layer between test groups in the coronal and apical sections. They were cleaned in the coronal sections and uncleaned in the apical sections. In the middle section, group B was significantly cleaner (p < 0.05) than the other groups. In conclusion, surfactant in combination with EDTA did not improve root canal cleanliness and there is no difference between different EDTA concentrations in removing the smear layer.

  7. Cognitions about bodily purity attenuate stress perception.

    PubMed

    Kaspar, Kai; Cames, Sarah

    2016-12-09

    Based on the assumption that physical purity is associated with a clean slate impression, we examined how cognitions about bodily cleanliness modulate stress perception. Participants visualized themselves in a clean or dirty state before reporting the frequency of stress-related situations experienced in the past. In Study 1 (n = 519) and Study 2 (n = 647) cleanliness versus dirtiness cognitions reliably reduced stress perception. Further results and a mediation analysis revealed that this novel effect was not simply driven by participants' cognitive engagement in stress recall. Moreover, we found that participants' temporal engagement in the recall of past stressful events negatively correlated with the amount of perceived stress, indicating an ease-of-retrieval phenomenon. However, a direct manipulation of the number of recalled stressful events in Study 3 (n = 792) showed the opposite effect: few versus many recalled events increased the perceived frequency of past stress-related situations. Overall, these novel results indicate an interesting avenue for future research on cognitively oriented stress reduction interventions, add to the literature on purity-related clean slate effects, and may help to better understand washing rituals in patients with obsessive-compulsive disorders.

  8. Investigating the intrinsic cleanliness of automated handling designed for EUV mask pod-in-pod systems

    NASA Astrophysics Data System (ADS)

    Brux, O.; van der Walle, P.; van der Donck, J. C. J.; Dress, P.

    2011-11-01

    Extreme Ultraviolet Lithography (EUVL) is the most promising solution for technology nodes 16nm (hp) and below. However, several unique EUV mask challenges must be resolved for a successful launch of the technology into the market. Uncontrolled introduction of particles and/or contamination into the EUV scanner significantly increases the risk for device yield loss and potentially scanner down-time. With the absence of a pellicle to protect the surface of the EUV mask, a zero particle adder regime between final clean and the point-of-exposure is critical for the active areas of the mask. A Dual Pod concept for handling EUV masks had been proposed by the industry as means to minimize the risk of mask contamination during transport and storage. SuSS-HamaTech introduces MaskTrackPro InSync as a fully automated solution for the handling of EUV masks in and out of this Dual Pod System and therefore constitutes an interface between various tools inside the Fab. The intrinsic cleanliness of each individual handling and storage step of the inner shell (EIP) of this Dual Pod and the EUV mask inside the InSync Tool has been investigated to confirm the capability for minimizing the risk of cross-contamination. An Entegris Dual Pod EUV-1000A-A110 has been used for the qualification. The particle detection for the qualification procedure was executed with the TNO's RapidNano Particle Scanner, qualified for particle sizes down to 50nm (PSL equivalent). It has been shown that the target specification of < 2 particles @ 60nm per 25 cycles has been achieved. In case where added particles were measured, the EIP has been identified as a potential root cause for Ni particle generation. Any direct Ni-Al contact has to be avoided to mitigate the risk of material abrasion.

  9. Toward Lower Organic Environments in Astromaterial Sample Curation for Diverse Collections

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Allen, C. C.; Burkett, P. J.; Calaway, M. J.; Oehler, D. Z.

    2012-01-01

    Great interest was taken during the frenzied pace of the Apollo lunar sample return to achieve and monitor organic cleanliness. Yet, the first mission resulted in higher organic contamination to samples than desired. But improvements were accomplished by Apollo 12 [1]. Quarantine complicated the goal of achieving organic cleanliness by requiring negative pressure glovebox containment environments, proximity of animal, plant and microbial organic sources, and use of organic sterilants in protocols. A special low organic laboratory was set up at University of California Berkeley (UCB) to cleanly subdivide a subset of samples [2, 3, 4]. Nevertheless, the basic approach of handling rocks and regolith inside of a positive pressure stainless steel glovebox and restrict-ing the tool and container materials allowed in the gloveboxes was established by the last Apollo sample re-turn. In the last 40 years, the collections have grown to encompass Antarctic meteorites, Cosmic Dust, Genesis solar wind, Stardust comet grains and Hayabusa asteroid grains. Each of these collections have unique curation requirements for organic contamination monitor-ing and control. Here is described some changes allowed by improved technology or driven by changes in environmental regulations and economy, concluding with comments on organic witness wafers. Future sample return missions (OSIRIS-Rex; Mars; comets) will require extremely low levels of organic contamination in spacecraft collection and thus similarly low levels in curation. JSC Curation is undertaking a program to document organic baseline levels in current operations and devise ways to reduce those levels.

  10. Bodily cleanliness in modern nursing.

    PubMed

    Boge, Jeanne; Kristoffersen, Kjell; Martinsen, Kari

    2013-04-01

    Why are bodily washing practices the way they are in nursing? Michel Foucault argues that modern democratic societies discipline human bodies in accordance with political interests. In the extension of that argumentation we will show that bodily cleanliness in modern nursing may have been used as a disciplining tool. The first part of our discussion takes as its point of departure the second half of the 19th/the beginning of the 20th centuries, the period in which modern nursing emerged. At that time scientific theories on hygiene seem to have legitimized the political effort to produce a clean, pleasant-smelling, decent, obedient, and productive population. Doctors, nurses and teachers played important roles in the implementation of hygienic bodily washing practices. The second part of the discussion focuses on the post-war period. At that time humanistic needs theories seem to have legitimized political argumentation for independent patients who washed themselves if possible. Those who could not manage on their own, should, as far as possible, be washed by cheaper staff, so that nurses could concentrate on medical treatment. Finally we argue that present day bodily washing practices in nursing are in accordance with the norms of appearance and smell that arose in the second half of the 19th and the first part of the 20th centuries. We further argue that staff with little or no education perform much of the bodily nursing work. Self-care seems to be of interest only when it reduces public expenses. © 2013 Blackwell Publishing Ltd.

  11. Establishment of Production Cleanliness Criteria and Processes for Printed Wiring Boards and Assemblies.

    DTIC Science & Technology

    1981-12-01

    H (hydrogen) and He (helium) are excluded since they have no outer shell electrons to eject. If the thin film analysis capability of Auger is...comtaminant profiling (C/P) system instrumentation will detect and intepret the amounts of contaminant species in an extract in terms of parts-per-billion...Nadas, and P. Fennell Evans, J. Phys. Chem;, 74 (1970), 4572. 215 4’. FILMED 7 4-85 DTIC

  12. 'If an Eye Is Washed Properly, It Means It Would See Clearly': A Mixed Methods Study of Face Washing Knowledge, Attitudes, and Behaviors in Rural Ethiopia.

    PubMed

    Aiemjoy, Kristen; Stoller, Nicole E; Gebresillasie, Sintayehu; Shiferaw, Ayalew; Tadesse, Zerihun; Sewnet, Tegene; Ayele, Bezuayehu; Chanyalew, Melsew; Callahan, Kelly; Stewart, Aisha; Emerson, Paul M; Lietman, Thomas M; Keenan, Jeremy D; Oldenburg, Catherine E

    2016-10-01

    Face cleanliness is a core component of the SAFE (Surgery, Antibiotics, Facial cleanliness, and Environmental improvements) strategy for trachoma control. Understanding knowledge, attitudes, and behaviors related to face washing may be helpful for designing effective interventions for improving facial cleanliness. In April 2014, a mixed methods study including focus groups and a quantitative cross-sectional study was conducted in the East Gojjam zone of the Amhara region of Ethiopia. Participants were asked about face washing practices, motivations for face washing, use of soap (which may reduce bacterial load), and fly control strategies. Overall, both knowledge and reported practice of face washing was high. Participants reported they knew that washing their own face and their children's faces daily was important for hygiene and infection control. Although participants reported high knowledge of the importance of soap for face washing, quantitative data revealed strong variations by community in the use of soap for face washing, ranging from 4.4% to 82.2% of households reporting using soap for face washing. Cost and forgetfulness were cited as barriers to the use of soap for face washing. Keeping flies from landing on children was a commonly cited motivator for regular face washing, as was trachoma prevention. Interventions aiming to improve facial cleanliness for trachoma prevention should focus on habit formation (to address forgetfulness) and address barriers to the use of soap, such as reducing cost. Interventions that focus solely on improving knowledge may not be effective for changing face-washing behaviors.

  13. Verification of cleaning efficiency and its possible role in programmed hygiene inspections of food businesses undertaken by local authority officers.

    PubMed

    Tebbutt, G; Bell, V; Aislabie, J

    2007-04-01

    The aim of this study was to determine whether or not the assessment of surface cleanliness could make a contribution to visual inspections of food premises. Forty-five premises were studied with both rapid (ATP) and traditional microbiological swabbing being used to test surfaces that either come into direct contact with prepared foods or were likely to be touched by hands during food preparation. A significant link was found between aerobic colony counts and ATP measurements. In most cases, the visual appearance of surfaces could not be used to accurately predict either microbial or ATP results. This study suggests that ATP testing is a useful indicator of surface cleanliness and could be helpful to local authority officers as part of risk assessment inspections. This study provides further evidence that visual inspection alone may not always be adequate to assess surface cleanliness. In high-risk premises, ATP could, if appropriately targeted, help identify potential problem areas. The results are available at the time of the inspection and can be used as an on-the-spot teaching aid.

  14. Quality differentials and reproductive health service utilisation determinants in India.

    PubMed

    Anand, Sandip; Sinha, R K

    2010-01-01

    This paper seeks to establish relationships between women's reproductive health service use, assessed longitudinally and by facility type, with service quality perceptions related to public or private health facilities. The study was mainly secondary and quantitative in nature. It included analysing data collected by the International Institute for Population Sciences (IIPS) and The Johns Hopkins University (JHU) as a follow-up study to the 1998-1999 National Family Health Survey (NFHS-2). The follow-up survey was carried out in Tamil Nadu, Maharashtra, Bihar and Jharkhand. In 2002-2003, these four states were selected to capture socio-economic and demographic variations. Analysis includes composite indices and logistic regression analysis. A scale was constructed to measure utilisation levels. Dimensions include: service proximity, doctor availability, waiting time, medicines, facility cleanliness, dignified treatment, privacy, service affordability and treatment effectiveness. Findings indicate that doctor availability, waiting time, cleanliness, privacy and affordability at private health facilities enhance the probability that a health facility will be used for any reproductive health purpose. At the combined states level, medicine availability and treatment effectiveness at public health facilities enhances service use. The major limitation is that the study includes only selected Indian states. The findings may enhance Indian service-quality policy. The paper's main contribution is that seemingly for the first time in India, healthcare service use has been measured longitudinally and then explained through service quality variables by comparing public and private health facilities.

  15. Quantitative Hydrocarbon Surface Analysis

    NASA Technical Reports Server (NTRS)

    Douglas, Vonnie M.

    2000-01-01

    The elimination of ozone depleting substances, such as carbon tetrachloride, has resulted in the use of new analytical techniques for cleanliness verification and contamination sampling. The last remaining application at Rocketdyne which required a replacement technique was the quantitative analysis of hydrocarbons by infrared spectrometry. This application, which previously utilized carbon tetrachloride, was successfully modified using the SOC-400, a compact portable FTIR manufactured by Surface Optics Corporation. This instrument can quantitatively measure and identify hydrocarbons from solvent flush of hardware as well as directly analyze the surface of metallic components without the use of ozone depleting chemicals. Several sampling accessories are utilized to perform analysis for various applications.

  16. Megasonic cleaning strategy for sub-10nm photomasks

    NASA Astrophysics Data System (ADS)

    Hsu, Jyh-Wei; Samayoa, Martin; Dress, Peter; Dietze, Uwe; Ma, Ai-Jay; Lin, Chia-Shih; Lai, Rick; Chang, Peter; Tuo, Laurent

    2016-10-01

    One of the main challenges in photomask cleaning is balancing particle removal efficiency (PRE) with pattern damage control. To overcome this challenge, a high frequency megasonic cleaning strategy is implemented. Apart from megasonic frequency and power, photomask surface conditioning also influences cleaning performance. With improved wettability, cleanliness is enhanced while pattern damage risk is simultaneously reduced. Therefore, a particle removal process based on higher megasonic frequencies, combined with proper surface pre-treatment, provides improved cleanliness without the unintended side effects of pattern damage, thus supporting the extension of megasonic cleaning technology into 10nm half pitch (hp) device node and beyond.

  17. [Cleanliness Norms 1964-1975].

    PubMed

    Noelle-Neumann, E

    1976-01-01

    In 1964 the Institut für Demoskopie Allensbach made a first survey taking stock of norms concerning cleanliness in the Federal Republic of Germany. At that time, 78% of respondents thought that the vogue among young people of cultivating an unkempt look was past or on the wane (Table 1.). Today we know that this fashion was an indicator of more serious desires for change in many different areas like politics, sexual morality, education and that its high point was still to come. In the fall of 1975 a second survey, modelled on the one of 1964, was conducted. Again, it concentrated on norms, not on behavior. As expected, norms have changed over this period but not in a one-directional or simple manner. In general, people are much more large-minded about children's looks: neat, clean school-dress, properly combed hair, clean shoes, all this and also holding their things in order has become less important in 1975 (Table 2). To carry a clean handkerchief is becoming oldfashioned (Table 3). On the other hand, principles of bringing-up children have not loosened concerning personal hygiene - brushing ones teeth, washing hands, feet, and neck, clean fingernails (Table 4). On one item related to protection of the environment, namely throwing around waste paper, standards have even become more strict (Table 5). With regard to school-leavers, norms of personal hygiene have generally become more strict (Table 6). As living standards have gone up and the number of full bathrooms has risen from 42% to 75% of households, norms of personal hygiene have also increased: one warm bath a week seemed enough to 56% of adults in 1964, but to only 32% in 1975 (Table 7). Also standards for changing underwear have changed a lot: in 1964 only 12% of respondents said "every day", in 1975 48% said so (Table 8). Even more stringent norms are applied to young women (Tables 9/10). For comparison: 1964 there were automatic washing machines in 16%, 1975 in 79% of households. Answers to questions which qualities men value especially in women and which qualities women value especially in men show a decrease in valutation of "cleanliness". These results can be interpreted in different ways (Tables 11/12). It seems, however, that "cleanliness" is not going out as a cultural value. We have found that young people today do not consider clean dress important but that they are probably better washed under their purposely neglected clothing than young people were ten years ago. As a nation, Germans still consider cleanliness to be a articularly German virtue, 1975 even more so than 1964 (Table 13). An association test, first made in March 1976, confirms this: When they hear "Germany", 68% of Germans think of "cleanliness" (Table 14).

  18. Evaluation of hygiene practices and microbiological status of ready-to-eat vegetable salads in Spanish school canteens.

    PubMed

    Rodríguez-Caturla, Magdevis Y; Valero, Antonio; Carrasco, Elena; Posada, Guiomar D; García-Gimeno, Rosa M; Zurera, Gonzalo

    2012-08-30

    This study was conducted in eight Spanish school canteens during the period 2008-2009. Food handlers' practices, kitchen equipment, hygiene/sanitation conditions and handling practices were evaluated using checklists. In parallel, the microbiological quality and safety of ready-to-eat (RTE) vegetable salads were assessed. In addition, food contact surfaces and environmental air quality of different areas were analysed. The study determined the relationship between the microbiological quality of RTE foods and food handling practices, together with the degree of contamination of working surfaces and environmental contamination of processing and distribution areas. Some deficiencies were found regarding the use and change of gloves, hand-washing and cleanliness of working surfaces. The microbial levels detected in the foods examined indicated the absence of pathogens in the samples analysed. Surface counts were higher on cutting boards and faucets, showing insufficient cleanliness procedures. This study constitutes a descriptive analysis of the hygiene/sanitation conditions implemented in food service systems in eight Spanish school canteens. The results should help risk managers to better define control measures to be adopted in order to prevent foodborne infections. Copyright © 2012 Society of Chemical Industry.

  19. Effect of ventilation rate on air cleanliness and energy consumption in operation rooms at rest.

    PubMed

    Lee, Shih-Tseng; Liang, Ching-Chieh; Chien, Tsung-Yi; Wu, Feng-Jen; Fan, Kuang-Chung; Wan, Gwo-Hwa

    2018-02-27

    The interrelationships between ventilation rate, indoor air quality, and energy consumption in operation rooms at rest are yet to be understood. We investigate the effect of ventilation rate on indoor air quality indices and energy consumption in ORs at rest. The study investigates the air temperature, relative humidity, concentrations of carbon dioxide, particulate matter (PM), and airborne bacteria at different ventilation rates in operation rooms at rest of a medical center. The energy consumption and cost analysis of the heating, ventilating, and air conditioning (HVAC) system in the operation rooms at rest were also evaluated for all ventilation rates. No air-conditioned operation rooms had very highest PM and airborne bacterial concentrations in the operation areas. The bacterial concentration in the operation areas with 6-30 air changes per hour (ACH) was below the suggested level set by the United Kingdom (UK) for an empty operation room. A 70% of reduction in annual energy cost by reducing the ventilation rate from 30 to 6 ACH was found in the operation rooms at rest. Maintenance of operation rooms at ventilation rate of 6 ACH could save considerable amounts of energy and achieve the goal of air cleanliness.

  20. Whisker Formation on SAC305 Soldered Assemblies

    NASA Astrophysics Data System (ADS)

    Meschter, S.; Snugovsky, P.; Bagheri, Z.; Kosiba, E.; Romansky, M.; Kennedy, J.; Snugovsky, L.; Perovic, D.

    2014-11-01

    This article describes the results of a whisker formation study on SAC305 assemblies, evaluating the effects of lead-frame materials and cleanliness in different environments: low-stress simulated power cycling (50-85°C thermal cycling), thermal shock (-55°C to 85°C), and high temperature/high humidity (85°C/85% RH). Cleaned and contaminated small outline transistors, large leaded quad flat packs (QFP), plastic leaded chip carrier packages, and solder balls with and without rare earth elements (REE) were soldered to custom designed test boards with Sn3Ag0.5Cu (SAC305) solder. After assembly, all the boards were cleaned, and half of them were recontaminated (1.56 µg/cm2 Cl-). Whisker length, diameter, and density were measured. Detailed metallurgical analysis on components before assembly and on solder joints before and after testing was performed. It was found that whiskers grow from solder joint fillets, where the thickness is less than 25 µm, unless REE was present. The influence of lead-frame and solder ball material, microstructure, cleanliness, and environment on whisker characteristics is discussed. This article provides detailed metallurgical observations and select whisker length data obtained during this multiyear testing program.

  1. Chemometric models for the quantitative descriptive sensory analysis of Arabica coffee beverages using near infrared spectroscopy.

    PubMed

    Ribeiro, J S; Ferreira, M M C; Salva, T J G

    2011-02-15

    Mathematical models based on chemometric analyses of the coffee beverage sensory data and NIR spectra of 51 Arabica roasted coffee samples were generated aiming to predict the scores of acidity, bitterness, flavour, cleanliness, body and overall quality of coffee beverage. Partial least squares (PLS) were used to construct the models. The ordered predictor selection (OPS) algorithm was applied to select the wavelengths for the regression model of each sensory attribute in order to take only significant regions into account. The regions of the spectrum defined as important for sensory quality were closely related to the NIR spectra of pure caffeine, trigonelline, 5-caffeoylquinic acid, cellulose, coffee lipids, sucrose and casein. The NIR analyses sustained that the relationship between the sensory characteristics of the beverage and the chemical composition of the roasted grain were as listed below: 1 - the lipids and proteins were closely related to the attribute body; 2 - the caffeine and chlorogenic acids were related to bitterness; 3 - the chlorogenic acids were related to acidity and flavour; 4 - the cleanliness and overall quality were related to caffeine, trigonelline, chlorogenic acid, polysaccharides, sucrose and protein. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Assessment of interplay between UV wavelengths, material surfaces and food residues in open surface hygiene validation.

    PubMed

    Abban, Stephen; Jakobsen, Mogens; Jespersen, Lene

    2014-12-01

    The use of UV-visible radiation for detecting invisible residue on different surfaces as a means of validating cleanliness was investigated. Wavelengths at 365, 395, 435, 445, 470 and 490 nm from a monochromator were used to detect residues of beef, chicken, apple, mango and skim milk. These were on three surfaces: aluminium, fibre re-enforced plastic (FRP; Q-Liner®) and stainless steel, pre- and post a cleaning step using commercial detergent. The area covered by residues as detected by specific wavelengths was compared statistically. The sensitivity of the wavelengths for detection differed significantly (p < 0.05) for various residues depending on the material surfaces. Generally, wavelengths 365-445 nm were consistently able to illuminate all residue before cleaning, though sensitivity varied, while 490 nm showed more of the surface structural features instead of residue. The 365-395 nm wavelengths were significantly more sensitive (p < 0.05) for detecting beef and chicken residues on aluminium and stainless steel both before and after cleaning. The 435-445 nm wavelengths were significantly more sensitive for detecting apple and mango residues on the FRP both before and after cleaning. It is important when UV-systems are used as real-time tools for assessing cleanliness of surfaces that the surface materials being illuminated are taken into account in the choice of lamp wavelength, in addition to expected residue. This will ensure higher confidence in results during the use of UV-light for real-time hygiene validation of surfaces.

  3. Safety of a 1-Day Polyethylene Glycol 3350 Bowel Preparation for Colonoscopy in Children.

    PubMed

    Sahn, Benjamin; Chen-Lim, Mei Lin; Ciavardone, Denise; Farace, Lisa; Jannelli, Frances; Nieberle, Megan; Ely, Elizabeth; Zhang, Xuemei; Kelsen, Judith; Puma, Anita; Mamula, Petar

    2016-07-01

    Electrolyte-free polyethylene glycol powder (PEG-3350) has been widely used for colonoscopy preparation (prep); however, limited safety data on electrolyte changes exists with 1-day prep regimens. The primary aim of this study was to determine the proportion of patients with significant serum chemistry abnormalities before and at the time of colonoscopy. Secondary aims included evaluation of prep tolerance and bowel cleansing efficacy. We performed a prospective descriptive observational study of pediatric patients scheduled for outpatient colonoscopy who received our standard 1-day, weight-based 4 g/kg PEG-3350 prep with a single stimulant laxative dose and had serum chemistry testing within 60 days before and at the time of colonoscopy. A standardized bowel cleanliness tool (Aronchick scale) was completed by the endoscopist. One hundred fifty-five patients had serum electrolytes data pre- and postprep. Comparison of each patient's chemistries demonstrated statistical equivalence with the 1 exception of blood urea nitrogen levels (P = 0.56). Hypokalemia was detected postprep in 37 subjects (24%), but none had a serum level <3.3 mmol/L, which was deemed to be of no clinical significance. Five patients were hypoglycemic post prep; 3 were 7 years or younger (P = 0.02). The colon cleanliness rating was excellent or good in 77% and suboptimal in 23% of patients. A 1-day, weight-based PEG-3350 bowel prep in children appears safe. Changes in electrolyte levels and renal function were not clinically significant. Children of 7 years or younger seem to be at a higher risk of hypoglycemia compared with older children.

  4. Behaviour change intervention to improve shared toilet maintenance and cleanliness in urban slums of Dhaka: a cluster-randomised controlled trial.

    PubMed

    Alam, Mahbub-Ul; Winch, Peter J; Saxton, Ronald E; Nizame, Fosiul A; Yeasmin, Farzana; Norman, Guy; Masud, Abdullah-Al; Begum, Farzana; Rahman, Mahbubur; Hossain, Kamal; Layden, Anita; Unicomb, Leanne; Luby, Stephen P

    2017-08-01

    Shared toilets in urban slums are often unclean and poorly maintained, discouraging consistent use and thereby limiting impacts on health and quality of life. We developed behaviour change interventions to support shared toilet maintenance and improve user satisfaction. We report the intervention effectiveness on improving shared toilet cleanliness. We conducted a cluster-randomised controlled trial among users of 1226 shared toilets in 23 Dhaka slums. We assessed baseline toilet cleanliness in January 2015. The six-month intervention included provision of hardware (bin for solid waste, 4 l flushing bucket, 70 l water reservoir), and behaviour change communication (compound meetings, interpersonal household sessions, signs depicting rules for toilet use). We estimated the adjusted difference in difference (DID) to assess outcomes and accounted for clustering effects using generalised estimating equations. Compared to controls, intervention toilets were more likely to have water available inside toilet cubicles (DID: +4.7%, 95% CI: 0.2, 9.2), access to brush/broom for cleaning (DID: +8.4%, 95% CI: 2, 15) and waste bins (DID: +63%, 95% CI: 59, 66), while less likely to have visible faeces inside the pan (DID: -13%, 95% CI: -19, -5), the smell of faeces (DID: -7.6%, 95% CI: -14, -1.3) and household waste inside the cubicle (DID: -4%, 95% CI: -7, -1). In one of few efforts to promote shared toilet cleanliness, intervention compounds were significantly more likely to have cleaner toilets after six months. Future research might explore how residents can self-finance toilet maintenance, or employ mass media to reduce per-capita costs of behaviour change. © 2017 John Wiley & Sons Ltd.

  5. [Evaluation of root canal isthmus debridement efficacy of Er:YAG laser in combination with sodium hypochlorite].

    PubMed

    Zhou, Meng-Qi; Wang, Hao-Ming; Xiao, Jia-Qi; Hong, Jin

    2016-10-01

    To histologically evaluate the efficacy of sodium hypochlorite (NaClO) in combination with Er:YAG (erbium-doped yttrium aluminium garnet) laser in dissolving necrotic tissue and cleaning root canals as well as canal isthmuses. After scanned by cone-beam CT (CBCT), 50 well-prepared premolars with root canal isthmuses were selected and randomly assigned into 5 groups. They were subsequently subjected to different regimens as followed: group A-irrigated with 1% NaClO for 1 minute, group B- irradiated by Er:YAG laser at 0.5 W combined with 1% NaClO irrigation for 1 minute, group C- irradiated by Er:YAG laser at 1.0 W combined with 1% NaClO irrigation for 1 minute, group D- irradiated by Er:YAG laser at 2.0 W combined with 1% NaClO irrigation for 1 minute,group E- negative control. After histological preparation and staining, the cross-sections were evaluated for percentage of tissue removal from root canals and isthmuses. The cleanliness values were calculated using SPSS 13.0 software package. The mean percentage of root canals in group A, B, C and D was 95.24%, 96.53%、97.63% and 98.22%, respectively, and the mean percentage of isthmuses was 16.50%, 51.48%, 52.56% and 53.83%, respectively. The mean percentage of root canal and isthmus cleanliness values were significantly higher in group B, C and D (P<0.05) than that in group A. There was no significant differences of root canal and isthmus cleanliness among group B, C and D. Er:YAG laser combined with 1% NaClO irrigation may be used effectively in root canal and root canal isthmus cleanliness as a new method.

  6. Four Fallacies and an Oversight: Searching for Martian Life

    NASA Astrophysics Data System (ADS)

    Rummel, J. D.; Conley, C. A.

    2017-10-01

    While it is anticipated that future human missions to Mars will increase the amount of biological and organic contamination that might be distributed on that planet, robotic missions continue to grow in capability and complexity, requiring precautions to be taken now to protect Mars, and particularly areas of Mars that might be Special Regions. Such precautionary cleanliness requirements for spacecraft have evolved over the course of the space age, as we have learned more about planetary environments, and are the subject of regular deliberations and decisions sponsored by the Committee on Space Research (COSPAR). COSPAR's planetary protection policy is maintained as an international consensus standard for spacecraft cleanliness that is recognized by the United Nations Committee on the Peaceful Uses of Outer Space. In response to the paper presented in this issue by Fairén et al. (2017), we examine both their concept of evidence for possible life on Mars and their logic in recommending that spacecraft cleanliness requirements be relaxed to access Special Regions "before it is too late." We find that there are shortcomings in their plans to look for evidence of life on Mars, that they do not support their contention that appropriate levels of spacecraft cleanliness are unaffordable, that there are major risks in assuming martian life could be identified by nucleic acid sequence comparison (especially if those sequences are obtained from a Special Region contaminated with Earth life), and that the authors do not justify their contention that exploration with dirty robots, now, is preferable to the possibility that later contamination will be spread by human exploration. We also note that the potential effects of contaminating resources and environments essential to future human occupants of Mars are both significant and not addressed by Fairén et al. (2017).

  7. ATP bioluminescence: Surface hygiene monitoring in milk preparation room of neonatal intensive care unit

    NASA Astrophysics Data System (ADS)

    Mohamad, Mahirah; Ishak, Shareena; Jaafar, Rohana; Sani, Norrakiah Abdullah

    2018-04-01

    ATP Bioluminescence application and standard microbiological analyses were used to evaluate the cleanliness of milk contact surfaces and non-milk contact surfaces in milk preparation room of neonatal intensive care unit (NICU) of Universiti Kebangsaan Malaysia Medical Centre (UKMMC). A total of 44 samples including the breast pump, milk bottle, milk bottle screw top and screw ring, teats, measuring cups, waterless warmer, refrigerator, dishwasher and pasteurizer inner wall were tested on May 2017. 3M Clean and Trace Hygiene Monitoring (UXL100 ATP Test swabs) and the bioluminescence reader Clean-Trace NG Luminometer (3M) were used to measure the Relative Light Unit (RLU) and microbiological analysis using 3M Quick Swab and 3MTM PetrifilmTM for enumeration of aerobic count, Staphylococcus aureus, Enterobacteriaceae, coliform and detection of Escherichia coli (CFU /100cm2 or utensil/item). The RLU values were from 11 to 194 and passed the ATP benchmark for intensive care unit (ICU), < 250 RLU as recommended. Aerobic colony count was only found in waterless warmer (0.05±0.01 mean log CFU/warmer). None of S. aureus, Enterobacteriaceae, E. coli and coliform was detected in all samples. A weak correlation was found between bioluminescence measurements RLU and the microbiological analysis (CFU). However, the use of ATP bioluminescence in monitoring milk preparation room cleanliness can be a useful method for assessing rapidly the surface hygiene as well as to verify the Sanitation Standard Operating Procedure (SSOP) prior to implementation of Hazard Analysis and Critical Control Points (HACCP) in milk preparation room.

  8. Surface Inspection Machine Infrared (SIMIR). Final CRADA report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, G.L.; Neu, J.T.; Beecroft, M.

    This Cooperative Research and Development Agreement was a one year effort to make the surface inspection machine based on diffuse reflectance infrared spectroscopy (Surface Inspection Machine-Infrared, SIMIR), being developed by Surface Optics Corporation, perform to its highest potential as a practical, portable surface inspection machine. The design function of the SIMIR is to inspect metal surfaces for cleanliness (stains). The system is also capable of evaluating graphite-resin systems for cure and heat damage, and for measuring the effects of moisture exposure on lithium hydride, corrosion on uranium metal, and the constituents of and contamination on wood, paper, and fabrics. Overmore » the period of the CRADA, extensive experience with the use of the SIMIR for surface cleanliness measurements have been achieved through collaborations with NASA and the Army. The SIMIR was made available to the AMTEX CRADA for Finish on Yarn where it made a very significant contribution. The SIMIR was the foundation of a Forest Products CRADA that was developed over the time interval of this CRADA. Surface Optics Corporation and the SIMIR have been introduced to the chemical spectroscopy on-line analysis market and have made staffing additions and arrangements for international marketing of the SIMIR as an on-line surface inspection device. LMES has been introduced to a wide range of aerospace applications, the research and fabrication skills of Surface Optics Corporation, has gained extensive experience in the areas of surface cleanliness from collaborations with NASA and the Army, and an extensive introduction to the textile and forest products industries. The SIMIR, marketed as the SOC-400, has filled an important new technology need in the DOE-DP Enhanced Surveillance Program with instruments delivered to or on order by LMES, LANL, LLNL, and Pantex, where extensive collaborations are underway to implement and improve this technology.« less

  9. How Clean Are Hotel Rooms? Part I: Visual Observations vs. Microbiological Contamination.

    PubMed

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Current evidence of hotel room cleanliness is based on observation rather than empirically based microbial assessment. The purpose of the study described here was to determine if observation provides an accurate indicator of cleanliness. Results demonstrated that visual assessment did not accurately predict microbial contamination. Although testing standards have not yet been established for hotel rooms and will be evaluated in Part II of the authors' study, potential microbial hazards included the sponge and mop (housekeeping cart), toilet, bathroom floor, bathroom sink, and light switch. Hotel managers should increase cleaning in key areas to reduce guest exposure to harmful bacteria.

  10. Multisite evaluation of environmental cleanliness of high-touch surfaces in intensive care unit patient rooms.

    PubMed

    Hopman, Joost; Donskey, Curtis J; Boszczowski, Icaro; Alfa, Michelle J

    2018-05-23

    The efficacy of discharge cleaning and disinfection of high-touch surfaces of intensive care unit patient rooms in Brazil, Canada, the Netherlands, and the United States was evaluated and the effect of an educational intervention was determined. Significant site-to-site differences in cleaning regimens and baseline cleanliness levels were observed using ATP levels, colony-forming units, and reflective surface marker removal percent pass rates. An educational intervention that includes rapid feedback of the ATP measurements could significantly improve the quality of the cleaning and disinfection regimens. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.

  11. Hygiene behaviour and hospitalized severe childhood diarrhoea: a case-control study.

    PubMed

    Baltazar, J C; Tiglao, T V; Tempongko, S B

    1993-01-01

    The relationship between personal and domestic hygiene behaviour and hospitalized childhood diarrhoea was examined in a case-control study of 356 cases and 357 controls from low-income families in metropolitan Manila. Indices of hygiene behaviour were defined for overall cleanliness, kitchen hygiene, and living conditions. Only the indices for overall cleanliness and kitchen hygiene were significantly associated with diarrhoea. An increasing excess risk of hospitalization with severe diarrhoea was noted as the ratings for standards of hygiene became lower, and this excess risk persisted even after controlling for confounding variables. The implications of our findings for the control of diarrhoeal disease are discussed.

  12. Hygiene behaviour and hospitalized severe childhood diarrhoea: a case-control study.

    PubMed Central

    Baltazar, J. C.; Tiglao, T. V.; Tempongko, S. B.

    1993-01-01

    The relationship between personal and domestic hygiene behaviour and hospitalized childhood diarrhoea was examined in a case-control study of 356 cases and 357 controls from low-income families in metropolitan Manila. Indices of hygiene behaviour were defined for overall cleanliness, kitchen hygiene, and living conditions. Only the indices for overall cleanliness and kitchen hygiene were significantly associated with diarrhoea. An increasing excess risk of hospitalization with severe diarrhoea was noted as the ratings for standards of hygiene became lower, and this excess risk persisted even after controlling for confounding variables. The implications of our findings for the control of diarrhoeal disease are discussed. PMID:8324851

  13. Mg-Ca Alloys Produced by Reduction of CaO: Understanding of ECO-Mg Alloy Production

    NASA Astrophysics Data System (ADS)

    Jung, In-Ho; Lee, Jin Kyu; Kim, Shae K.

    2017-04-01

    There have been long debates about the environment conscious (ECO) Mg technology which utilizes CaO to produce Ca-containing Mg alloys. Two key process technologies of the ECO-Mg process are the chemical reduction of CaO by liquid Mg and the maintenance of melt cleanliness during the alloying of Ca. Thermodynamic calculations using FactSage software were performed to explain these two key issues. In addition, an experimental study was performed to compare the melt cleanliness of the Ca-containing Mg alloys produced by the conventional route with metallic Ca and the ECO-Mg route with CaO.

  14. The influence of cultural factors on obsessive compulsive disorder: religious symptoms in a religious society.

    PubMed

    Greenberg, D; Witztum, E

    1994-01-01

    Judaism is one of many religions that demand cleanliness and exactness, inculcate the performance of rituals from childhood and view their non-performance as wrong or sinful. Rituals concerning cleanliness and exactness are the commonest presentations of OCD. In a sample of 34 psychiatric out-patients with OCD in north Jerusalem, religious symptoms were found in 13 of the 19 ultra-orthodox patients, and in one of the 15 non-ultra-orthodox patients. Nine of the 15 OCD patients with religious symptoms also had non-religious symptoms. Four main topics of religious symptomatology were found: prayer, dietary practices, menstrual practices and cleanliness before prayer. The dictates of religious codes regarding these topics are presented and the law is rigorous in its demands, in many cases encouraging repeating rituals. Nevertheless, repetitive performance of religious rituals is recognized by OCD sufferers and their rabbis as expressing psychopathology rather than heightened spirituality. The forms of the religious obsessions and the associated rituals in this sample were similar to the presentation of OCD in non-religious patients. Religion appears not to be a distinctive topic of OCD, rather it is the setting for the condition in very religious patients.

  15. Purity and cleanness of aerogel as a cosmic dust capture medium

    NASA Technical Reports Server (NTRS)

    Tsou, P.; Fleming, R. H.; Lindley, P. M.; Craig, A. Y.; Blake, D.

    1994-01-01

    The capability for capturing micrometeoroids intact through laboratory simulations and in space in passive underdense silica aerogel offers a valuable tool for cosmic dust research. The integrity of the sample handling medium can substantially modify the integrity of the sample. Intact capture is a violent hypervelocity event: the integrity of the capturing medium can cause even greater modification of the sample. Doubts of the suitability of silica aerogel as a capture medium were raised at the 20th LPSC, and questions were raised again at the recent workshop on Particle Capture, Recovery, and Velocity Trajectory Measurement Technologies. Assessment of aerogel's volatile components and carbon contents have been made. We report the results of laboratory measurements of the purity and cleanliness of silica aerogel used for several Sample Return Experiments flown on the Get Away Special program.

  16. Surface inspection using FTIR spectroscopy

    NASA Technical Reports Server (NTRS)

    Powell, G. L.; Smyrl, N. R.; Williams, D. M.; Meyers, H. M., III; Barber, T. E.; Marrero-Rivera, M.

    1995-01-01

    The use of reflectance Fourier transform infrared (FTIR) spectroscopy as a tool for surface inspection is described. Laboratory instruments and portable instruments can support remote sensing probes that can map chemical contaminants on surfaces with detection limits under the best of conditions in the sub-nanometer range, i.e.. near absolute cleanliness, excellent performance in the sub-micrometer range, and useful performance for films tens of microns thick. Examples of discovering and quantifying contamination such as mineral oils and greases, vegetable oils, and silicone oils on aluminum foil, galvanized sheet steel, smooth aluminum tubing, and sandblasted 7075 aluminum alloy and D6AC steel. The ability to map in time and space the distribution of oil stains on metals is demonstrated. Techniques associated with quantitatively applying oils to metals, subsequently verifying the application, and non-linear relationships between reflectance and the quantity oil are described.

  17. High cleanliness globe valve with sine mechanism drive

    NASA Astrophysics Data System (ADS)

    Luo, Hu

    2018-06-01

    This paper gives a new type of quick-opening globe valve for life support pneumatic control system of the safety cabin at underground coal mine. The valve adopts the sine mechanism to transmit the rotating of the handle in the range of 90° to the reciprocating motion of the spool. The mechanism implements the quick-opening function of the valve through controlling the contact and separation between the O-ring and the end face of the valve. Since there is no relative sliding between the sealing interfaces, the valve solute uncontrollable disadvantage wear particles which produced by package ball valve, to ensure high cleanliness in flow path. Traditional transmission mechanism has a reinforcement effect and reduce handle open torque. By the finite element method, the relationship between the contact force and the compression of O-ring is analyzed to provide the boundary condition for the calculation of the rotational torque. Meanwhile the velocity field and pressure field along the flow path are simulated. The caliber size of the valve and the flow resistance coefficient are obtained. There is higher cleanliness, more reliable sealing, smaller handle open torque advantage compared with existing packing ball valve. The above work presents a new technical approach for the design of pneumatic control valve of the safety cabin.

  18. Advanced lithographic filtration and contamination control for 14nm node and beyond semiconductor processes

    NASA Astrophysics Data System (ADS)

    Varanasi, Rao; Mesawich, Michael; Connor, Patrick; Johnson, Lawrence

    2017-03-01

    Two versions of a specific 2nm rated filter containing filtration medium and all other components produced from high density polyethylene (HDPE), one subjected to standard cleaning, the other to specialized ultra-cleaning, were evaluated in terms of their cleanliness characteristics, and also defectivity of wafers processed with photoresist filtered through each. With respect to inherent cleanliness, the ultraclean version exhibited a 70% reduction in total metal extractables and 90% reduction in organics extractables compared to the standard clean version. In terms of particulate cleanliness, the ultraclean version achieved stability of effluent particles 30nm and larger in about half the time required by the standard clean version, also exhibiting effluent levels at stability almost 90% lower. In evaluating defectivity of blanket wafers processed with photoresist filtered through either version, initial defect density while using the ultraclean version was about half that observed when the standard clean version was in service, with defectivity also falling more rapidly during subsequent usage of the ultraclean version compared to the standard clean version. Similar behavior was observed for patterned wafers, where the enhanced defect reduction was primarily of bridging defects. The filter evaluation and actual process-oriented results demonstrate the extreme value in using filtration designed possessing the optimal intrinsic characteristics, but with further improvements possible through enhanced cleaning processes

  19. Two types of squalor: findings from a factor analysis of the Environmental Cleanliness and Clutter Scale (ECCS).

    PubMed

    Snowdon, John; Halliday, Graeme; Hunt, Glenn E

    2013-07-01

    Most people who collect and hoard, and then have difficulty discarding items, do not live in squalor, even though accumulation of hoarded items can make cleaning very difficult. Commonly, people living in squalor accumulate garbage, but relatively few fulfill proposed criteria for "hoarding disorder." We examined the overlap between hoarding and squalor among people referred because of unacceptable living conditions. Ongoing collection of data by a Squalor Project team, including ratings on the Environmental Cleanliness and Clutter Scale (ECCS), allowed (1) description of characteristics of cases and (2) examination of ratings of uncleanliness, and of the effect of accumulation of items or material on access within dwellings. Principal component analysis was used to examine latent variables underlying the ECCS. The mean age of the referred occupants (108 male, 95 female) was 61.9 years. The mean ECCS score in 186 rated cases was 18.5. Factor analysis of ECCS data showed a two-factor solution as the most plausible. Factor 1, comprising seven squalor items, accounted for 33.7% of the variance. Factor 2 comprised reduced accessibility and accumulation of items of little value (variance 17.6%). Accumulation of garbage loaded equally on the two factors. High levels of squalor and/or accumulation were recorded in 105 (56%) of the 186 dwellings. One-third scored high on accumulation/hoarding, while 38% scored high on squalor; 15% scored high on both squalor and accumulation. A quarter of those scoring high on squalor scored low on hoarding/accumulation. The ECCS is useful when describing whether referred cases show high levels of squalor, hoarding, or both.

  20. Four Fallacies and an Oversight: Searching for Martian Life

    PubMed Central

    Conley, C.A.

    2017-01-01

    Abstract While it is anticipated that future human missions to Mars will increase the amount of biological and organic contamination that might be distributed on that planet, robotic missions continue to grow in capability and complexity, requiring precautions to be taken now to protect Mars, and particularly areas of Mars that might be Special Regions. Such precautionary cleanliness requirements for spacecraft have evolved over the course of the space age, as we have learned more about planetary environments, and are the subject of regular deliberations and decisions sponsored by the Committee on Space Research (COSPAR). COSPAR's planetary protection policy is maintained as an international consensus standard for spacecraft cleanliness that is recognized by the United Nations Committee on the Peaceful Uses of Outer Space. In response to the paper presented in this issue by Fairén et al. (2017), we examine both their concept of evidence for possible life on Mars and their logic in recommending that spacecraft cleanliness requirements be relaxed to access Special Regions “before it is too late.” We find that there are shortcomings in their plans to look for evidence of life on Mars, that they do not support their contention that appropriate levels of spacecraft cleanliness are unaffordable, that there are major risks in assuming martian life could be identified by nucleic acid sequence comparison (especially if those sequences are obtained from a Special Region contaminated with Earth life), and that the authors do not justify their contention that exploration with dirty robots, now, is preferable to the possibility that later contamination will be spread by human exploration. We also note that the potential effects of contaminating resources and environments essential to future human occupants of Mars are both significant and not addressed by Fairén et al. (2017). Key Words: Mars—Special Region—Mission—Life detection—Planetary protection. Astrobiology 17, 971–974. PMID:28920443

  1. Protecting Your Home from Bed Bugs

    EPA Pesticide Factsheets

    Take precautions such as checking secondhand furniture for signs of infestation before bringing it home, using mattress encasements, sealing cracks, installing door sweeps, and maintaining cleanliness.

  2. Assessing fluorescent color: a review of common practices and their limitations

    NASA Astrophysics Data System (ADS)

    Streitel, Steve

    2003-07-01

    Fluorescent Colorants are widely used around the world to enhance visibility. The outstanding brightness and cleanliness of the colors lend themselves to applications in safety materials, advertising, toys, magazines, packaging, and other areas. The brightness and cleanliness is a result of the colorants ability to reradiate absorbed energy as visible light, usually shorter more energetic photons as longer less energetic photons. This can give reflectance values of well over 100%, sometimes as high as 300%, in the perceived color. A good working definition of fluorescent color is: A colorant that absorbs light energy and reradiates the energy at visible wavelengths. Light that is not absorbed is reflected, as in conventional color. Emission ceases when the excitation energy is removed.

  3. A dirty animal is a scary animal! Effects of disgust-related information on fear beliefs in children.

    PubMed

    Muris, Peter; Mayer, Birgit; Huijding, Jorg; Konings, Tjeerd

    2008-01-01

    The present study investigated whether disgust-valenced information has an impact on children's fear beliefs about animals. Non-clinical children aged between 9 and 13 years (n=159) were presented with disgust-related and cleanliness-related information about unknown animals (Australian marsupials). Before and after information, beliefs of disgust and fear regarding the animals were assessed. Results showed that disgust-related information not only induced higher levels of disgust but also increased children's fear beliefs in relation to these animals. The other way around, cleanliness-related information decreased levels of disgust and resulted in lower levels of fear. The implications for the role of disgust in the development of animal fear are briefly discussed.

  4. A noncontacting scanning photoelectron emission technique for bonding surface cleanliness inspection

    NASA Technical Reports Server (NTRS)

    Gause, Raymond L.

    1989-01-01

    Molecular contamination of bonding surfaces can drastically affect the bond strength that can be achieved and therefore the structural integrity and reliability of the bonded part. The presence of thin contaminant films on bonding surfaces can result from inadequate or incomplete cleaning methods, from oxide growth during the time between cleaning (such as grit blasting) and bonding, or from failure to properly protect cleaned surfaces from oils, greases, fingerprints, release agents, or deposition of facility airborne molecules generated by adjacent manufacturing or processing operations. Required cleanliness levels for desired bond performance can be determined by testing to correlate bond strength with contaminant type and quantity, thereby establishing the degree of contamination that can be tolerated based on the strength that is needed. Once the maximum acceptable contaminant level is defined, a method is needed to quantitatively measure the contaminant level on the bonding surface prior to bonding to verify that the surface meets the established cleanliness requirement. A photoelectron emission technique for the nondestructive inspection of various bonding surfaces, both metallic and nonmetallic, to provide quantitative data on residual contaminant levels is described. The technique can be used to scan surfaces at speeds of at least 30 ft/min using a servo system to maintain required sensor to surface spacing. The fundamental operation of the photoelectron emission sensor system is explained and the automated scanning system and computer data acquisition hardware and software are described.

  5. Brushing Your Spacecrafts Teeth: A Review of Biological Reduction Processes for Planetary Protection Missions

    NASA Technical Reports Server (NTRS)

    Pugel, D. E. (Betsy); Rummel, J. D.; Conley, Catharine

    2017-01-01

    Much like keeping your teeth clean, where you brush away biofilms that your dentist calls "plaque," there are various methods to clean spaceflight hardware of biological contamination, known as biological reduction processes. Different approaches clean your hardware's "teeth" in different ways and with different levels of effectiveness. We know that brushing at home with a simple toothbrush is convenient and has a different level of impact vs. getting your teeth cleaned at the dentist. In the same way, there are some approaches to biological reduction that may require simple tools or more complex implementation approaches (think about sonicating or just soaking your dentures, vs. brushing them). There are also some that are more effective for different degrees of cleanliness and still some that have materials compatibility concerns. In this article, we review known and NASA-certified approaches for biological reduction, pointing out materials compatibility concerns and areas where additional research is needed.

  6. Brushing Your Spacecrafts Teeth: A Review of Biological Reduction Processes for Planetary Protection Missions

    NASA Technical Reports Server (NTRS)

    Pugel, D.E. (Betsy); Rummel, J. D.; Conley, C. A.

    2017-01-01

    Much like keeping your teeth clean, where you brush away biofilms that your dentist calls plaque, there are various methods to clean spaceflight hardware of biological contamination, known as biological reduction processes. Different approaches clean your hardwares teeth in different ways and with different levels of effectiveness. We know that brushing at home with a simple toothbrush is convenient and has a different level of impact vs. getting your teeth cleaned at the dentist. In the same way, there are some approaches to biological reduction that may require simple tools or more complex implementation approaches (think about sonicating or just soaking your dentures, vs. brushing them). There are also some that are more effective for different degrees of cleanliness and still some that have materials compatibility concerns. In this article, we review known and NASA-certified approaches for biological reduction, pointing out materials compatibility concerns and areas where additional research is needed.

  7. Frequency and risk-factors analysis of Escherichia coli O157:H7 in Bali-cattle.

    PubMed

    Suardana, I Wayan; Widiasih, Dyah Ayu; Nugroho, Widagdo Sri; Wibowo, Michael Haryadi; Suyasa, I Nyoman

    2017-08-01

    Cattle are known as the main reservoir of zoonotic agents verocytotoxin-producing Escherichia coli. These bacteria are usually isolated from calves with diarrhea and/or mucus and blood. Tolerance of these agents to the environmental conditions will strengthen of their transmission among livestock. A total of 238 cattle fecal samples from four sub-districts in Badung, Bali were used in this study. Epidemiological data observed include cattle age, sex, cattle rearing system, the source of drinking water, weather, altitude, and type of cage floor, the cleanliness of cage floor, the slope of cage floor, and the level of cattle cleanliness. The study was initiated by culturing of samples onto eosin methylene blue agar, then Gram stained, and tested for indole, methyl-red, voges proskauer, and citrate, Potential E.coli isolates were then cultured onto sorbitol MacConkey agar, and further tested using O157 latex agglutination test and H7 antisera. Molecular identification was performed by analysis of the 16S rRNA gene, and epidemiological data was analyzed using STATA 12.0 software. The results showed, the prevalence of E. coli O157:H7 in cattle at Badung regency was 6.30% (15/238) covering four sub districts i.e. Petang, Abiansemal, Mengwi, and Kuta which their prevalence was 8.62%(5/58), 10%(6/60), 3.33%(2/60), and 3.33(2/60)%, respectively. The analysis of 16S rRNA gene confirmed of isolates as an E. coli O157:H7 strain with 99% similarities. Furthermore, the risk factors analysis showed that the slope of the cage floor has a highly significant effect (P<0.05) to the distribution of infection. Consequently, implementing this factor must be concerned in order to decrease of infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Analysis and Derivation of Allocations for Fiber Contaminants in Liquid Bipropellant Systems

    NASA Technical Reports Server (NTRS)

    Lowrey, N. M; ibrahim, K. Y.

    2012-01-01

    An analysis was performed to identify the engineering rationale for the existing particulate limits in MSFC-SPEC-164, Cleanliness of Components for Use in Oxygen, Fuel, and Pneumatic Systems, determine the applicability of this rationale to fibers, identify potential risks that may result from fiber contamination in liquid oxygen/fuel bipropellant systems, and bound each of these risks. The objective of this analysis was to determine whether fiber contamination exceeding the established quantitative limits for particulate can be tolerated in these systems and, if so, to derive and recommend quantitative allocations for fibers beyond the limits established for other particulate. Knowledge gaps were identified that limit a complete understanding of the risk of promoted ignition from an accumulation of fibers in a gaseous oxygen system.

  9. Secondary analysis of hospital patient experience scores across England's National Health Service - How much has improved since 2005?

    PubMed

    Honeyford, Kate; Greaves, Felix; Aylin, Paul; Bottle, Alex

    2017-01-01

    To examine trends in patient experience and consistency between hospital trusts and settings. Observational study of publicly available patient experience surveys of three hospital settings (inpatients (IP), accident and emergency (A&E) and outpatients (OP)) of 130 acute NHS hospital trusts in England between 2004/05 and 2014/15. Overall patient experience has been good, showing modest improvements over time across the three hospital settings. Individual questions with the biggest improvement across all three settings are cleanliness (IP: +7.1, A&E: +6.5, OP: +4.7) and information about danger signals (IP: +3.8, A&E: +3.9, OP: +4.0). Trust performance has been consistent over time: 71.5% of trusts ranked in the same cluster for more than five years. There is some consistency across settings, especially between outpatients and inpatients. The lowest-scoring questions, regarding information at discharge, are the same in all years and all settings. The greatest improvement across all three settings has been for cleanliness, which has seen national policies and targets. Information about danger signals and medication side-effects showed least consistency across settings and scores have remained low over time, despite information about danger signals showing a big increase in score. Patient experience of aspects of access and waiting have declined, as has experience of discharge delay, likely reflecting known increases in pressure on England's NHS.

  10. Use of a Sampling Area-Adjusted Adenosine Triphosphate Bioluminescence Assay Based on Digital Image Quantification to Assess the Cleanliness of Hospital Surfaces.

    PubMed

    Ho, Yu-Huai; Wang, Lih-Shinn; Jiang, Hui-Li; Chang, Chih-Hui; Hsieh, Chia-Jung; Chang, Dan-Chi; Tu, Hsin-Yu; Chiu, Tan-Yun; Chao, Huei-Jen; Tseng, Chun-Chieh

    2016-06-09

    Contaminated surfaces play an important role in the transmission of pathogens. We sought to establish a criterion that could indicate "cleanliness" using a sampling area-adjusted adenosine triphosphate (ATP) assay. In the first phase of the study, target surfaces were selected for swab sampling before and after daily cleaning; then, an aerobic colony count (ACC) plate assay of bacteria and antibiotic-resistant bacteria was conducted. ATP swabs were also tested, and the ATP readings were reported as relative light units (RLUs). The results of the ACC and ATP assays were adjusted according to the sampling area. During the second phase of the study, a new cleaning process employing sodium dichloroisocyanurate (NaDCC) was implemented for comparison. Using the criterion of 2.5 colony-forming units (CFU)/cm², 45% of the sampled sites were successfully cleaned during phase one of the study. During phase two, the pass rates of the surface samples (64%) were significantly improved, except under stringent (5 RLU/cm²) and lax (500 RLU) ATP criteria. Using receiver-operating characteristic curve analysis, the best cut-off point for an area-adjusted ATP level was 7.34 RLU/cm², which corresponded to culture-assay levels of <2.5 CFU/cm². An area adjustment of the ATP assay improved the degree of correlation with the ACC-assay results from weak to moderate.

  11. Cleanliness of Ti-bearing Al-killed ultra-low-carbon steel during different heating processes

    NASA Astrophysics Data System (ADS)

    Guo, Jian-long; Bao, Yan-ping; Wang, Min

    2017-12-01

    During the production of Ti-bearing Al-killed ultra-low-carbon (ULC) steel, two different heating processes were used when the converter tapping temperature or the molten steel temperature in the Ruhrstahl-Heraeus (RH) process was low: heating by Al addition during the RH decarburization process and final deoxidation at the end of the RH decarburization process (process-I), and increasing the oxygen content at the end of RH decarburization, heating and final deoxidation by one-time Al addition (process-II). Temperature increases of 10°C by different processes were studied; the results showed that the two heating processes could achieve the same heating effect. The T.[O] content in the slab and the refining process was better controlled by process-I than by process-II. Statistical analysis of inclusions showed that the numbers of inclusions in the slab obtained by process-I were substantially less than those in the slab obtained by process-II. For process-I, the Al2O3 inclusions produced by Al added to induce heating were substantially removed at the end of decarburization. The amounts of inclusions were substantially greater for process-II than for process-I at different refining stages because of the higher dissolved oxygen concentration in process-II. Industrial test results showed that process-I was more beneficial for improving the cleanliness of molten steel.

  12. Small business initiative -- Surface inspection machine infrared (SIMIR)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, G.L.; Beecroft, M.

    This Cooperative Research and Development Agreement was a one year effort to make the surface inspection machine based on diffuse reflectance infrared spectroscopy (Surface Inspection Machine-Infrared, SIMIR), being developed by Surface Optics Corporation, perform to its highest potential as a practical, portable surface inspection machine. A secondary purpose was to evaluate applications that would serve both the private and the public sector. The design function of the SIMIR is to inspect sandblasted metal surfaces for cleanliness (stains). The system is also capable of evaluating graphite-resin systems for cure and heat damage, and for measuring the effects of moisture exposure onmore » lithium hydride, corrosion on uranium metal, and the constituents of and contamination on wood, paper, and fabrics. Surface Optics Corporation supplied LMES-Y12 with a prototype SOC-400 that was evaluated by LMES-Y12 and rebuilt by Surface Optics to achieve the desired performance. LMES-Y12 subsequently evaluated the instrument against numerous applications including determining part cleanliness at the Corpus Christi Army Depot, demonstrating the ability to detect plasticizers and other organic contaminants on metals to Pantex and LANL personnel, analyzed sandblasted metal contamination standards supplied by NASA-MSFC, and demonstrated to Lockheed Martin Tactical Aircraft, marietta, GA, for analyzing the paint applied to the F-22 Fighter. The instrument also demonstrated the analysis of yarn, fabric, and finish on the textiles.« less

  13. 7 CFR 1437.307 - Mushrooms.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... growing medium must consist of a substrate (a habitat and nutrient base) sterilized by heat treatment. (d... at a minimum: (1) Adequate hygiene; (2) Overall cleanliness; (3) Isolation or minimum contact...

  14. 7 CFR 1437.307 - Mushrooms.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... growing medium must consist of a substrate (a habitat and nutrient base) sterilized by heat treatment. (d... at a minimum: (1) Adequate hygiene; (2) Overall cleanliness; (3) Isolation or minimum contact...

  15. Relation of attitude toward body elimination to parenting style and attitude toward the body.

    PubMed

    Corgiat, Claudia A; Templer, Donald I

    2003-04-01

    The purpose was to estimate the relation of attitude toward body elimination in 93 college students (27 men and 66 women), to authoritarian personality features, participants' perception of their mothers' parenting style, and attitudes toward cleanliness, sex, and family nudity. Subjects were administered the Body Elimination Attitude Scale, the Four-item F Scale, the Parental Authority Questionnaire Pertaining to Mothers, and the items "Sex is dirty," "Cleanliness is next to godliness," and "Children should never see other family members nude." Larger scores for disgust toward body elimination were associated with authoritarian personality characteristics, being less likely to describe mother's parenting style as authoritative (open communication) and more likely to describe it as authoritarian and lower scores for tolerance for family nudity. Implications for further research were suggested.

  16. New Developments in Magnetostatic Cleanliness Modeling

    NASA Astrophysics Data System (ADS)

    Mehlem, K.; Wiegand, A.; Weickert, S.

    2012-05-01

    The paper describes improvements and extensions of the multiple magnetic dipole modeling method (MDM) for cleanliness verification which had been introduced by the author1 in 1977 and then applied during 3 decades to numerous international projects. The solutions of specific modeling problems which had been left unsolved so far, are described in the present paper. Special attention is given to the ambiguities of MDM solutions caused by the limited data coverage available. Constraint handling by the constraint-free NLP solver, optimal MDM sizing and multiple-point far-field compensation techniques are presented. The recent extension of the MDM method to field gradient data is formulated and demonstrated by an example. Finally, a complex MDM application (Ulysses) is presented. Finally, a short description of the MDM software GAMAG, recently introduced by the author1, is given.

  17. Salivary gland infections

    MedlinePlus

    ... duct stones Poor cleanliness in the mouth ( oral hygiene ) Low amounts of water in the body, most ... to help with recovery include: Practice good oral hygiene. Brush your teeth and floss well at least ...

  18. Behind the Seams.

    ERIC Educational Resources Information Center

    Watt, W. Bradford

    2000-01-01

    Discusses the use of seamless flooring in areas where cleanliness, waterproofing, and slip resistance is emphasized. Areas such as locker rooms, restrooms, kitchens and cafeterias, lobbies and hallways, multipurpose-rooms, and walkways are considered. (GR)

  19. 7 CFR 58.129 - Cleanliness.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... outer garments and caps (paper caps, hard hats, or hair nets acceptable) shall be worn to adequately protect the hair and beards when grown by all persons engaged in receiving, testing, processing milk...

  20. 7 CFR 58.129 - Cleanliness.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... outer garments and caps (paper caps, hard hats, or hair nets acceptable) shall be worn to adequately protect the hair and beards when grown by all persons engaged in receiving, testing, processing milk...

  1. 7 CFR 58.129 - Cleanliness.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... outer garments and caps (paper caps, hard hats, or hair nets acceptable) shall be worn to adequately protect the hair and beards when grown by all persons engaged in receiving, testing, processing milk...

  2. 7 CFR 58.129 - Cleanliness.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... outer garments and caps (paper caps, hard hats, or hair nets acceptable) shall be worn to adequately protect the hair and beards when grown by all persons engaged in receiving, testing, processing milk...

  3. 7 CFR 58.129 - Cleanliness.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... outer garments and caps (paper caps, hard hats, or hair nets acceptable) shall be worn to adequately protect the hair and beards when grown by all persons engaged in receiving, testing, processing milk...

  4. How clean is your clean room?

    PubMed

    Govier, J

    2006-01-01

    After investment in a clean room, cleanliness, sanitisation or sterility is essential to ensuring it operates at the highest standard. This article advises on the products and maintenance procedures to achieve this.

  5. Effect of information about animal welfare on consumer willingness to pay for yogurt.

    PubMed

    Napolitano, F; Pacelli, C; Girolami, A; Braghieri, A

    2008-03-01

    This study aimed to verify whether consumers confirm their willingness to pay extra costs for higher animal welfare standards in a situation where a potential purchase performed by consumers, such as the Vickrey auction, is used. A 104-member consumer panel was asked to rate its willingness to pay (WTP) for plain and low-fat yogurts in 3 information conditions: tasting without information (blind WTP), information about animal welfare without tasting (expected WTP), tasting with information about animal welfare (actual WTP). Information was provided to the consumers under the form of labels indicating the level of animal cleanliness and freedom of movement (5-point scale, from poor to very good). Consumers were influenced by information about low standards of animal welfare (low cleanliness and low freedom of movement) and moved their willingness to pay in the direction of their expectations. However, the discrepancy between expectancy and actual WTP was not totally assimilated, indicating that WTP was also expressed in relation to other aspects (e.g., the sensory properties of the products). Conversely, the information concerning high standards of animal welfare (high cleanliness and high freedom of movement) was able to affect expectancy but had an effect on actual WTP only when the most acceptable yogurt was offered to the consumers. In the case of discordant information on animal welfare, partly indicating high levels of welfare (freedom of movements) and low levels of welfare (cleanliness), expected WTP was always lower than blind WTP. However, when the least acceptable product was presented, they completely assimilated their actual WTP to the expectations. Conversely, with the most acceptable yogurt, no assimilation occurred and sensory properties prevailed in orienting consumer WTP. Within each product, consumers expressed a higher WTP for products with labels indicating high welfare standards as compared with yogurts with labels reporting intermediate and low welfare standard. These results show that information about animal welfare, if given to the consumers, can be a major determinant of consumer WTP for animal-based food products. However, information about high standards of animal welfare should be paired with products presenting a good eating quality.

  6. Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care

    PubMed Central

    2014-01-01

    Background Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). Methods The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. Results The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Conclusions Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care. PMID:24593868

  7. Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care.

    PubMed

    Watanabe, Reina; Shimoda, Tomoko; Yano, Rika; Hayashi, Yasuhiro; Nakamura, Shinji; Matsuo, Junji; Yamaguchi, Hiroyuki

    2014-03-04

    Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care.

  8. 24 CFR 982.401 - Housing quality standards (HQS).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... capable of maintaining a thermal environment healthy for the human body. (2) Acceptability criteria. (i... must be in proper operating condition, and adequate for personal cleanliness and the disposal of human...

  9. Environmental Control and Life Support Systems

    NASA Technical Reports Server (NTRS)

    Engel, Joshua Allen

    2017-01-01

    The Environmental Control System provides a controlled air purge to Orion and SLS. The ECS performs this function by processing 100% ambient air while simultaneously controlling temperature, pressure, humidity, cleanliness and purge distribution.

  10. Clean Assembly of Genesis Collector Canister for Flight: Lessons for Planetary Sample Return

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Stansbery, E. K.; Allen, C. C.; Warren, J. L.; Schwartz, C. M.

    2007-01-01

    Measurement of solar composition in the Genesis collectors requires not only high sensitivity but very low blanks; thus, very strict collector contamination minimization was required beginning with mission planning and continuing through hardware design, fabrication, assembly and testing. Genesis started with clean collectors and kept them clean inside of a canister. The mounting hardware and container for the clean collectors were designed to be cleanable, with access to all surfaces for cleaning. Major structural components were made of aluminum and cleaned with megasonically energized ultrapure water (UPW). The UPW purity was >18 M resistivity. Although aluminum is relatively difficult to clean, the Genesis protocol achieved level 25 and level 50 cleanliness on large structural parts; however, the experience suggests that surface treatments may be helpful on future missions. All cleaning was performed in an ISO Class 4 (Class 10) cleanroom immediately adjacent to an ISO Class 4 assembly room; thus, no plastic packaging was required for transport. Persons assembling the canister were totally enclosed in cleanroom suits with face shield and HEPA filter exhaust from suit. Interior canister materials, including fasteners, were installed, untouched by gloves, using tweezers and other stainless steel tools. Sealants/lubricants were not exposed inside the canister, but vented to the exterior and applied in extremely small amounts using special tools. The canister was closed in ISO Class 4, not to be opened until on station at Earth-Sun L1. Throughout the cleaning and assembly, coupons of reference materials that were cleaned at the same time as the flight hardware were archived for future reference and blanks. Likewise reference collectors were archived. Post-mission analysis of collectors has made use of these archived reference materials.

  11. Listening to the occupants: a Web-based indoor environmental quality survey.

    PubMed

    Zagreus, Leah; Huizenga, Charlie; Arens, Edward; Lehrer, David

    2004-01-01

    Building occupants are a rich source of information about indoor environmental quality and its effect on comfort and productivity. The Center for the Built Environment has developed a Web-based survey and accompanying online reporting tools to quickly and inexpensively gather, process and present this information. The core questions assess occupant satisfaction with the following IEQ areas: office layout, office furnishings, thermal comfort, indoor air quality, lighting, acoustics, and building cleanliness and maintenance. The survey can be used to assess the performance of a building, identify areas needing improvement, and provide useful feedback to designers and operators about specific aspects of building design features and operating strategies. The survey has been extensively tested and refined and has been conducted in more than 70 buildings, creating a rapidly growing database of standardized survey data that is used for benchmarking. We present three case studies that demonstrate different applications of the survey: a pre/post analysis of occupants moving to a new building, a survey used in conjunction with physical measurements to determine how environmental factors affect occupants' perceived comfort and productivity levels, and a benchmarking example of using the survey to establish how new buildings are meeting a client's design objectives. In addition to its use in benchmarking a building's performance against other buildings, the CBE survey can be used as a diagnostic tool to identify specific problems and their sources. Whenever a respondent indicates dissatisfaction with an aspect of building performance, a branching page follows with more detailed questions about the nature of the problem. This systematically collected information provides a good resource for solving indoor environmental problems in the building. By repeating the survey after a problem has been corrected it is also possible to assess the effectiveness of the solution.

  12. Surface contamination analysis technology team overview

    NASA Astrophysics Data System (ADS)

    Burns, H. Dewitt, Jr.

    1996-11-01

    The surface contamination analysis technology (SCAT) team was originated as a working roup of NASA civil service, Space Shuttle contractor, and university groups. Participating members of the SCAT Team have included personnel from NASA Marshall Space Flight Center's Materials and Processes Laboratory and Langley Research Center's Instrument Development Group; contractors-Thiokol Corporation's Inspection Technology Group, AC Engineering support contractor, Aerojet, SAIC, and Lockheed MArtin/Oak Ridge Y-12 support contractor and Shuttle External Tank prime contractor; and the University of Alabama in Huntsville's Center for Robotics and Automation. The goal of the SCAT team as originally defined was to develop and integrate a multi-purpose inspection head for robotic application to in-process inspection of contamination sensitive surfaces. One area of interest was replacement of ozone depleting solvents currently used for surface cleanliness verification. The team approach brought together the appropriate personnel to determine what surface inspection techniques were applicable to multi-program surface cleanliness inspection. Major substrates of interest were chosen to simulate space shuttle critical bonding surface or surfaces sensitive to contamination such as fuel system component surfaces. Inspection techniques evaluated include optically stimulated electron emission or photoelectron emission; Fourier transform infrared spectroscopy; near infrared fiber optic spectroscopy; and, ultraviolet fluorescence. Current plans are to demonstrate an integrated system in MSFC's Productivity Enhancement Complex within five years from initiation of this effort in 1992. Instrumentation specifications and designs developed under this effort include a portable diffuse reflectance FTIR system built by Surface Optics Corporation and a third generation optically stimulated electron emission system built by LaRC. This paper will discuss the evaluation of the various techniques on a number of substrate materials contaminated with hydrocarbons, silicones, and fluorocarbons. Discussion will also include standards development for instrument calibration and testing.

  13. [Cleanliness in the operating room].

    PubMed

    Suzuki, Toshiyasu

    2010-05-01

    With regard to recent findings in the cleanliness of the operating room, concerning handwashing and performing operations, the traditional method of excessive scrubbing using a brush is not effective, and handwashing using only an alcohol-containing antiseptic hand rub (rubbing method) has become common practice. Use of a brush has already been abolished in some medical institutions. In addition, sterilized water used for handwashing when performing operations has no scientific basis and use of tap water is considered sufficient. Furthermore, the concept of operating room zoning has also undergone a dramatic change. It was discovered that a layout focusing on work efficiency is more desirable than the one that follows an excessively rigid zoning pattern. One-footwear System not requiring change of shoes also has various advantages in improving the efficiency of the operation room, and this is thought to become commonplace in the future.

  14. Evaluation of alternative cleaners for solder flux and mold release removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopez, E.P.; Peebles, D.E.; Reich, J.E.

    1991-01-01

    As part of a solvent substitution program, an evaluation of selected alternative cleaners for solder flux and mold release removal has been performed. Six cleaners were evaluated for their efficiency in removing a rosin mildly activated flux and a silicone mold release from copper, 17-4PH stainless steel, polyimide quartz glass and tin-lead surfaces. A parallel effort also studied deionized water removal of organic acid fluxes. Auger electron spectroscopy and X-ray photoelectron spectroscopy were used to determine relative elemental cleanliness of the outermost atomic layers. An Omega Meter Test was used to measure residual ionic contamination. Water drop contact angles weremore » used to measure the effectiveness of silicone removal from Cu substrates. In most cases, the cleanliness levels were good to excellent. 10 refs., 8 figs., 19 tabs.« less

  15. Cleanliness of disposable vs nondisposable electrocardiography lead wires in children.

    PubMed

    Addison, Nancy; Quatrara, Beth; Letzkus, Lisa; Strider, David; Rovnyak, Virginia; Syptak, Virginia; Fuzy, Lisa

    2014-09-01

    Mediastinitis costs hospitals thousands of dollars a year and increases the incidence of patient morbidity and mortality. No studies have been done to evaluate adenosine triphosphate (ATP) counts on disposable and nondisposable electrocardiography (ECG) lead wires in pediatric patients. To compare the cleanliness of disposable and nondisposable ECG lead wires in postoperative pediatric cardiac surgery patients by measuring the quantity of ATP (in relative luminescence units [RLUs]). ATP levels correlate with microbial cell counts and are used by institutions to assess hospital equipment and cleanliness. A prospective, randomized trial was initiated with approval from the institutional review board. Verbal consent was obtained from the parents/guardians for each patient. Trained nurses performed ATP swabs on the right and left upper ECG cables on postoperative days 1, 2, and 3. This study enrolled 51 patients. The disposable ECG lead wire ATP count on postoperative day 1 (median, 157 RLUs) was significantly lower (P < .001) than the count for nondisposable ATP lead wires (median, 610 RLUs). On postoperative day 2, the ATP count for the disposable ECG lead wires (median, 200 RLUs) was also lower (P = .06) than the count for the nondisposable ECG lead wires (median, 453 RLUs). Results of this study support the use of disposable ECG lead wires in postoperative pediatric cardiac surgery patients for at least the first 48 hours as a direct strategy to reduce the ATP counts on ECG lead wires. ©2014 American Association of Critical-Care Nurses.

  16. 50 CFR 260.101 - Lavatory accommodations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... toilet and locker rooms and also at such other places as may be essential to the cleanliness of all... conspicuously in each toilet room and locker room directing employees to wash hands before returning to work. (e...

  17. 50 CFR 260.101 - Lavatory accommodations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... toilet and locker rooms and also at such other places as may be essential to the cleanliness of all... conspicuously in each toilet room and locker room directing employees to wash hands before returning to work. (e...

  18. 50 CFR 260.101 - Lavatory accommodations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... toilet and locker rooms and also at such other places as may be essential to the cleanliness of all... conspicuously in each toilet room and locker room directing employees to wash hands before returning to work. (e...

  19. Liver Disease

    MedlinePlus

    ... and don't share needles used to inject drugs. Use a condom during sex. If you choose to have tattoos or body piercings, be picky about cleanliness and safety when selecting a shop. Get vaccinated. If you're at increased risk ...

  20. High-power microstrip switch

    NASA Technical Reports Server (NTRS)

    Choi, S. D.

    1974-01-01

    Switch, which uses only two p-i-n diodes on microstrip substrate, has been developed for application in spacecraft radio systems. Switch features improved power drain, weight, volume, magnetic cleanliness, and reliability, over currently-used circulator and electromechanical switches.

  1. EVALUATION OF CURRENT SUSTAINABILITY ASSESSMENT OF BIOBASED TECHNOLOGY

    EPA Science Inventory

    Sustainable technology is driven by economic competitiveness, government policies and public pressure. The claim of inherent cleanliness for biotechnology is too simplistic. Each application of biotechnology must be evaluated for suitable characteristics of sustainability. The ...

  2. Animal health and welfare planning improves udder health and cleanliness but not leg health in Austrian dairy herds.

    PubMed

    Tremetsberger, Lukas; Leeb, Christine; Winckler, Christoph

    2015-10-01

    Animal health and welfare planning is considered an important tool for herd management; however, its effectiveness is less well known. The aim of this study was to conduct animal health and welfare planning on 34 Austrian dairy farms and to evaluate changes in health and welfare after 1 yr. After an initial assessment using the Welfare Quality protocol (Welfare Quality Consortium, Lelystad, the Netherlands), results were reported back to the farmers. Health and welfare area(s) in which both the farmer and the researcher regarded improvement as important were discussed. Management practices and husbandry measures were chosen according to the respective farm situation. One year after interventions had been initiated, farms were reassessed, and the degree of implementation of improvement measures was recorded. The average implementation rate was 57% and thus relatively high when compared with other studies. High degrees of implementation were achieved related to cleanliness and udder health, at 77 and 63%, respectively. Intervention measures addressing udder health were mostly easy to incorporate in the daily routine and led to a reduced somatic cell score, whereas this score increased in herds without implementation of measures. The decrease in cows with dirty teats was more pronounced when measures were implemented compared with control farms. The implementation rate regarding leg health (46%) was comparably low in the present study, and leg health did not improve even when measures were implemented. Lying comfort, social behavior, and human-animal relationship did not require interventions and were therefore seldom chosen by farmers as part of health and welfare plans. In conclusion, the structured, participatory process of animal health and welfare planning appears to be a promising way to improve at least some animal health and welfare issues. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Development of a Method for Evaluating Floor Dry-Cleanability from Wheat Flour in the Food Industry.

    PubMed

    Barreca, F; Cardinali, G D; Borgese, E; Russo, M

    2017-04-01

    Many productive processes are characterized by inadequate protocols of sanitation that increase the possibility of proliferation of microbial contaminants, especially on surfaces. The use of this method for evaluating the degree of floor cleanability in agri-food companies is important not only to reduce the risk of contamination of products, but also to provide companies with a tool to identify critical issues. The method is based on the usage of bicinchoninic acid assay (BCA) in a solution at a 1:50 ratio of Cu 2+ /BCA, which is ideal for detecting the amount of proteins contained in wheat flour residues on industrial flooring. Spectrophotometric analysis allowed identifying maximum absorbance values at 562 nm for different protein concentrations, although the construction of a regression function led to the definition of the intervals of evaluation corresponding to different degrees of cleanliness from residues of wheat flour. The results of the absorbance curves, obtained by applying the proposed evaluation method to 6 tiles commonly used in agri-food buildings, showed the clear persistence of food material on 2 tiles with surface relief. In particular, such tiles showed a higher presence of proteins, with a level of contamination 440% higher. Furthermore, a robotic system was designed to standardize the cleaning method commonly employed in agri-food companies to remove solid particles from flooring. © 2017 Institute of Food Technologists®.

  4. Evaluation of test equipment for the detection of contamination on electronic circuits

    NASA Astrophysics Data System (ADS)

    Bergendahl, C. G.; Dunn, B. D.

    1984-08-01

    The reproducibility, sensitivity and ease of operation of test equipment for the detection of ionizable contaminants on the surface of printed circuit assemblies were assessed. The characteristics of the test equipment are described. Soldering fluxes were chosen as contaminants and were applied in controlled amounts to printed-circuit board assemblies possessing two different component populations. Results show that the relationship between equipment readings varies with flux type. Each kind of test equipment gives a good measure of board cleanliness, although reservations exist concerning the interpretation of such results. A test method for the analysis of total (organic and inorganic) halides in solder fluxes is presented.

  5. Is Exposure to Animal Feces Harmful to Child Nutrition and Health Outcomes? A Multicountry Observational Analysis.

    PubMed

    Headey, Derek; Nguyen, Phuong; Kim, Sunny; Rawat, Rahul; Ruel, Marie; Menon, Purnima

    2017-04-01

    AbstractIt has recently been hypothesized that exposure to livestock constitutes a significant risk factor for diarrhea and environmental enteric disorder in young children, which may significantly contribute to undernutrition. To date, though, very little research has documented the extent of exposure to animal feces and whether this exposure is associated with child anthropometry in large samples and diverse settings. This study investigates these issues using data from the Alive and Thrive study conducted in rural areas of Ethiopia, Bangladesh, and Vietnam. These surveys used spot-checks to collect data on proxies of hygiene behaviors such as the cleanliness of mothers, young children, and the homestead environment, including the presence of animal feces. Animal feces were visible in 38-42% of household compounds across the three countries and were positively associated with household livestock ownership and negatively associated with maternal and child cleanliness. One-sided tests from multivariate least squares models for children 6-24 months of age indicate that the presence of animal feces is significantly and negatively associated with child height-for-age z scores in Ethiopia (β = -0.22), Bangladesh (β = -0.13), and in a pooled sample (β = -0.11), but not in Vietnam. There is also suggestive evidence that animal feces may be positively associated with diarrhea symptoms in Bangladesh. The results in this article, therefore, contribute to a growing body of evidence suggesting that animal ownership may pose a significant risk to child nutrition and health outcomes in developing countries.

  6. There’s more to food store choice than proximity: a questionnaire development study

    PubMed Central

    2013-01-01

    Background Proximity of food stores is associated with dietary intake and obesity; however, individuals frequently shop at stores that are not the most proximal. Little is known about other factors that influence food store choice. The current research describes the development of the Food Store Selection Questionnaire (FSSQ) and describes preliminary results of field testing the questionnaire. Methods Development of the FSSQ involved a multidisciplinary literature review, qualitative analysis of focus group transcripts, and expert and community reviews. Field testing consisted of 100 primary household food shoppers (93% female, 64% African American), in rural and urban Arkansas communities, rating FSSQ items as to their importance in store choice and indicating their top two reasons. After eliminating 14 items due to low mean importance scores and high correlations with other items, the final FSSQ questionnaire consists of 49 items. Results Items rated highest in importance were: meat freshness; store maintenance; store cleanliness; meat varieties; and store safety. Items most commonly rated as top reasons were: low prices; proximity to home; fruit/vegetable freshness; fruit/vegetable variety; and store cleanliness. Conclusions The FSSQ is a comprehensive questionnaire for detailing key reasons in food store choice. Although proximity to home was a consideration for participants, there were clearly other key factors in their choice of a food store. Understanding the relative importance of these different dimensions driving food store choice in specific communities may be beneficial in informing policies and programs designed to support healthy dietary intake and obesity prevention. PMID:23773428

  7. There's more to food store choice than proximity: a questionnaire development study.

    PubMed

    Krukowski, Rebecca A; Sparks, Carla; DiCarlo, Marisha; McSweeney, Jean; West, Delia Smith

    2013-06-17

    Proximity of food stores is associated with dietary intake and obesity; however, individuals frequently shop at stores that are not the most proximal. Little is known about other factors that influence food store choice. The current research describes the development of the Food Store Selection Questionnaire (FSSQ) and describes preliminary results of field testing the questionnaire. Development of the FSSQ involved a multidisciplinary literature review, qualitative analysis of focus group transcripts, and expert and community reviews. Field testing consisted of 100 primary household food shoppers (93% female, 64% African American), in rural and urban Arkansas communities, rating FSSQ items as to their importance in store choice and indicating their top two reasons. After eliminating 14 items due to low mean importance scores and high correlations with other items, the final FSSQ questionnaire consists of 49 items. Items rated highest in importance were: meat freshness; store maintenance; store cleanliness; meat varieties; and store safety. Items most commonly rated as top reasons were: low prices; proximity to home; fruit/vegetable freshness; fruit/vegetable variety; and store cleanliness. The FSSQ is a comprehensive questionnaire for detailing key reasons in food store choice. Although proximity to home was a consideration for participants, there were clearly other key factors in their choice of a food store. Understanding the relative importance of these different dimensions driving food store choice in specific communities may be beneficial in informing policies and programs designed to support healthy dietary intake and obesity prevention.

  8. Evaluation of Cleanliness Test Methods for Spacecraft PCB Assemblies

    NASA Astrophysics Data System (ADS)

    Tegehall, P.-E.; Dunn, B. D.

    2006-10-01

    Ionic contamination on printed-circuit-board assemblies may cause current leakage and short-circuits. The present cleanliness requirement in ECSS-Q-70-08, "The manual soldering of high-reliability electrical connections", is that the ionic contamination shall be less than 1.56 fl-glcm2 NaCI equivalents. The relevance of the method used for measurement of the ionic contamination level, resistivity of solvent extract, has been questioned. Alternative methods are ion chromatography and measurement of surface insulation resistance, but these methods also have their drawbacks. These methods are first described and their advantages and drawbacks are discussed. This is followed by an experimental evaluation of the three methods. This was done by soldering test vehicles at four manufacturers of space electronics using their ordinary processes for soldering and cleaning printed board assemblies. The experimental evaluation showed that the ionic contamination added by the four assemblers was very small and well below the acceptance criterion in ECSS-Q-70-80. Ion-chromatography analysis showed that most of the ionic contamination on the cleaned assembled boards originated from the hot-oil fusing of the printed circuit boards. Also, the surface insulation resistance was higher on the assembled boards compared to the bare printed circuit boards. Since strongly activated fluxes are normally used when printed circuit boards are hot-oil fused, it is essential that they are thoroughly cleaned in order to achieve low contamination levels on the final printed-board assemblies.

  9. Ensure preparation and capsule endoscopy: A two-center prospective study

    PubMed Central

    Niv, Eva; Ovadia, Baruch; Ron, Yulia; Santo, Ervin; Mahajna, Elisabeth; Halpern, Zamir; Fireman, Zvi

    2013-01-01

    AIM: To compare small bowel (SB) cleanliness and capsule endoscopy (CE) image quality following Ensure®, polyethylene glycol (PEG) and standard preparations. METHODS: A preparation protocol for CE that is both efficacious and acceptable to patients remains elusive. Considering the physiological function of the SB as a site for the digestion and absorption of food and not as a stool reservoir, preparation consisting of a liquid, fiber-free formula ingested one day before a CE study might have an advantage over other kinds of preparations. We conducted a prospective, blind-to-preparation, two-center study that compared four types of preparations. The participants’ demographic and clinical data were collected. Gastric and SB transit times were calculated. The presence of bile in the duodenum was scored by a single, blinded-to-preparation gastroenterologist expert in CE, as was cleanliness within the proximal, middle and distal part of the SB. A four-point scale was used (grade 1 = no bile or residue, grade 4 ≥ 90% of lumen full of bile or residual material). RESULTS: The 198 consecutive patients who were referred to CE studies due to routine medical reasons were divided into four groups. They all observed a 12-h overnight fast before undergoing CE. Throughout the 24 h preceding the fast, control group 1 (n = 45 patients) ate light unrestricted meals, control group 2 (n = 81) also ate light meals but free of fruits and vegetables, the PEG group (n = 50) ate unrestricted light meals and ingested the PEG preparation, and the Ensure group (n = 22) ingested only the Ensure formula. Preparation with Ensure improved the visualization of duodenal mucosa (a score of 1.76) by decreasing the bile content compared to preparation with PEG (a score of 2.9) (P = 0.053). Overall, as expected, there was less residue and stool in the proximal part of the SB than in the middle and distal parts in all groups. The total score of cleanliness throughout the length of the SB showed some benefit for Ensure (a score of 1.8) over control group 2 (a score of 2) (P = 0.06). The cleanliness grading of the proximal and distal parts of the SB was similar in all four groups (P = 0.6 for both). The cleanliness in the middle part of the SB in the PEG (a score of 1.8) and Ensure groups (a score of 1.7) was equally better than that of control group 2 (a score of 2.1) (P = 0.057 and P = 0.07, respectively). All 50 PEG patients had diarrhea as an anticipated side effect, compared with only one patient in the Ensure group. CONCLUSION: Preparation with Ensure, a liquid, fiber-free formula has advantages over standard and PEG preparations, with significantly fewer side effects than PEG. PMID:23483023

  10. Bioassays as one of the Green Chemistry tools for assessing environmental quality: A review.

    PubMed

    Wieczerzak, M; Namieśnik, J; Kudłak, B

    2016-09-01

    For centuries, mankind has contributed to irreversible environmental changes, but due to the modern science of recent decades, scientists are able to assess the scale of this impact. The introduction of laws and standards to ensure environmental cleanliness requires comprehensive environmental monitoring, which should also meet the requirements of Green Chemistry. The broad spectrum of Green Chemistry principle applications should also include all of the techniques and methods of pollutant analysis and environmental monitoring. The classical methods of chemical analyses do not always match the twelve principles of Green Chemistry, and they are often expensive and employ toxic and environmentally unfriendly solvents in large quantities. These solvents can generate hazardous and toxic waste while consuming large volumes of resources. Therefore, there is a need to develop reliable techniques that would not only meet the requirements of Green Analytical Chemistry, but they could also complement and sometimes provide an alternative to conventional classical analytical methods. These alternatives may be found in bioassays. Commercially available certified bioassays often come in the form of ready-to-use toxkits, and they are easy to use and relatively inexpensive in comparison with certain conventional analytical methods. The aim of this study is to provide evidence that bioassays can be a complementary alternative to classical methods of analysis and can fulfil Green Analytical Chemistry criteria. The test organisms discussed in this work include single-celled organisms, such as cell lines, fungi (yeast), and bacteria, and multicellular organisms, such as invertebrate and vertebrate animals and plants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. 42 CFR 441.365 - Periodic evaluation, assessment, and review.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... State government (such as the Department of Health or the Agency on Aging). (2) Each review team must... new § 441.365(g)(3)): (i) Cleanliness. (ii) Absence of bedsores. (iii) Absence of signs of...

  12. 42 CFR 441.365 - Periodic evaluation, assessment, and review.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... State government (such as the Department of Health or the Agency on Aging). (2) Each review team must... new § 441.365(g)(3)): (i) Cleanliness. (ii) Absence of bedsores. (iii) Absence of signs of...

  13. Techniques of biological contamination avoidance by atmospheric probes

    NASA Technical Reports Server (NTRS)

    Defrees, R. E.

    1974-01-01

    The likelihood of biologically contaminating a planet by an atmospheric probe has a low probability of occurring if the probe is kept biologically clean during terrestrial operations and if the structure remains in tact until the planets life zone is completely penetrated. High standards of cleanliness, monitoring and estimating for remedial actions must be maintained in a probe program. It is not a foregone conclusion, however, that heat sterilization needs to be employed. The use of several techniques having a good potential for lower probe costs are available and appear adequate to render a probe sterile within acceptable bounds. The techniques considered to be satisfactory for minimizing microbial load include: (1) combined heat (at 95-105 C) and gamma radiation; (2) short term heating at 105 + or - 5 C to inactivate all vegetative microbes; (3) irradiation routinely by ultraviolet light; (4) wiping by a bactericidal agent with or without a penetrant; and (5) cleanliness alone.

  14. Replacement of Hydrochlorofluorocarbon (HCFC) -225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems

    NASA Technical Reports Server (NTRS)

    Burns, H. D.; Mitchell, M. A.; McMillian, J. H.; Farner, B. R.; Harper, S. A.; Peralta, S. F.; Lowrey, N. M.; Ross, H. R.; Juarez, A.

    2015-01-01

    Since the 1990's, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have used hydrochlorofluorocarbon-225 (HCFC-225), a Class II ozone-depleting substance, to safety clean and verify the cleanliness of large scale propulsion oxygen systems and associated test facilities. In 2012 through 2014, test laboratories at MSFC, SSC, and Johnson Space Center-White Sands Test Facility collaborated to seek out, test, and qualify an environmentally preferred replacement for HCFC-225. Candidate solvents were selected, a test plan was developed, and the products were tested for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Honewell Soltice (TradeMark) Performance Fluid (trans-1-chloro-3,3, 3-trifluoropropene) was selected to replace HCFC-225 at NASA's MSFC and SSC rocket propulsion test facilities.

  15. Evaluation of a bonded particle cartridge filtration system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, W.; Krug, H.P.; Dopp, V.

    1996-10-01

    Metal cleanliness is a major issue in today`s aluminum casthouse, especially in the production of critical products such as canstock, litho sheet and foil. Bonded particle cartridge filters are widely regarded as the most effective means available for inclusion removal from critical production items. V.A.W. and Foseco have carried out a joint program of evaluation of a cartridge filter system in conjunction with ceramic foam filters and an in-line degassing unit--in various configurations. The ceramic foam filters ranged from standard, coarse pore types to new generation all-ceramic bonded, fine pore types. Metal cleanliness was assessed using LiMCA, PoDFA, and LAISmore » sampling techniques, as well as metallographic and scanning electron microscope examinations. This paper outlines the findings of this work which was carried out a V.A.W.`s full scale experimental D.C. slab casting unit as Neuss in Germany.« less

  16. Garbage monitoring system using IoT

    NASA Astrophysics Data System (ADS)

    Anitha, A.

    2017-11-01

    Nowadays certain actions are taken to improve the level of cleanliness in the country. People are getting more active in doing all the things possible to clean their surroundings. Various movements are also started by the government to increase cleanliness. We will try to build a system which will notify the corporations to empty the bin on time. In this system, we will put a sensor on top of the garbage bin which will detect the total level of garbage inside it according to the total size of the bin. When the garbage will reach the maximum level, a notification will be sent to the corporation's office, then the employees can take further actions to empty the bin. This system will help in cleaning the city in a better way. By using this system people do not have to check all the systems manually but they will get a notification when the bin will get filled.

  17. Spot-checks to measure general hygiene practice.

    PubMed

    Sonego, Ina L; Mosler, Hans-Joachim

    2016-01-01

    A variety of hygiene behaviors are fundamental to the prevention of diarrhea. We used spot-checks in a survey of 761 households in Burundi to examine whether something we could call general hygiene practice is responsible for more specific hygiene behaviors, ranging from handwashing to sweeping the floor. Using structural equation modeling, we showed that clusters of hygiene behavior, such as primary caregivers' cleanliness and household cleanliness, explained the spot-check findings well. Within our model, general hygiene practice as overall concept explained the more specific clusters of hygiene behavior well. Furthermore, the higher general hygiene practice, the more likely children were to be categorized healthy (r = 0.46). General hygiene practice was correlated with commitment to hygiene (r = 0.52), indicating a strong association to psychosocial determinants. The results show that different hygiene behaviors co-occur regularly. Using spot-checks, the general hygiene practice of a household can be rated quickly and easily.

  18. Magnetic Cleanliness Program Under Control of Electromagnetic Compatibility for the SELENE (Kaguya) Spacecraft

    NASA Astrophysics Data System (ADS)

    Matsushima, Masaki; Tsunakawa, Hideo; Iijima, Yu-Ichi; Nakazawa, Satoru; Matsuoka, Ayako; Ikegami, Shingo; Ishikawa, Tomoaki; Shibuya, Hidetoshi; Shimizu, Hisayoshi; Takahashi, Futoshi

    2010-07-01

    To achieve the scientific objectives related to the lunar magnetic field measurements in a polar orbit at an altitude of 100 km, strict electromagnetic compatibility (EMC) requirements were applied to all components and subsystems of the SELENE (Kaguya) spacecraft. The magnetic cleanliness program was defined as one of the EMC control procedures, and magnetic tests were carried out for most of the engineering and flight models. The EMC performance of all components was systematically controlled and examined through a series of EMC tests. As a result, the Kaguya spacecraft was made to be very clean, magnetically. Hence reliable scientific data related to the magnetic field around the Moon were obtained by the LMAG (Lunar MAGnetometer) and the PACE (Plasma energy Angle and Composition Experiment) onboard the Kaguya spacecraft. These data have been available for lunar science use since November 2009.

  19. Microbiological cleanliness of the Mars Exploration Rover spacecraft

    NASA Technical Reports Server (NTRS)

    Newlin, L.; Barengoltz, J.; Chung, S.; Kirschner, L.; Koukol, R.; Morales, F.

    2002-01-01

    Planetary protection for Mars missions is described, and the approach being taken by the Mars Exploration Rover Project is discussed. Specific topics include alcohol wiping, dry heat microbial reduction, microbiological assays, and the Kennedy Space center's PHSF clean room.

  20. Family Resemblance in Attitudes to Foods.

    ERIC Educational Resources Information Center

    Rozin, Paul; And Others

    1984-01-01

    Compares young adults with their parents and explores food preferences and attitudes to food, especially sensitivity to cleanliness and contamination of foods. Results indicate small positive parent-child correlations for food preferences but larger correlations for contamination sensitivity. (Author/AS)

  1. Thermoplastic Single-Ply Roof Relieves Water Damage and Inconvenience.

    ERIC Educational Resources Information Center

    Williams, Jennifer Lynn

    2002-01-01

    Assesses use of thermoplastic single-ply roofs by North Carolina's Mars Hill College to prevent leaks, reduce maintenance costs, and enhance the value of their older historic buildings. Administrators comment on the roof's installation efficiency and cleanliness. (GR)

  2. Effects of sand and straw bedding on the lying behavior, cleanliness, and hoof and hock injuries of dairy cows.

    PubMed

    Norring, M; Manninen, E; de Passillé, A M; Rushen, J; Munksgaard, L; Saloniemi, H

    2008-02-01

    This experiment compared the effects of sand and straw bedding in free stalls on resting time, cleanliness, hock injuries, and hoof health of dairy cows and tested whether cow preferences for a bedding material depended on the familiarity with the material. A total of 52 dairy cows were kept either on straw bedded concrete stalls or sand stalls for at least 21 wk. The lying behavior was observed, and hock lesions, hoof health, and cleanliness of the cows and stalls were measured. A 5-d preference test between sand and straw stalls was conducted at the end of the experiment. The total daily duration of lying was longer for cows on straw bedding than on sand bedding (straw 749 +/- 16 vs. sand 678 +/- 19 min). During the preference test, cows that had been kept on straw bedding preferred lying in straw stalls [straw 218.7 (133.4 to 239.7) vs. sand 9.0 min (2.8 to 44.8)]; however, cows that had been kept on sand showed no preference [straw 101.3 (51.7 to 205.9) vs. sand 94.3 min (54.1 to 156.1, median and interquartile range)]. Although there were no differences in the dirtiness of stalls, the cows using straw stalls were dirtier than cows using sand stalls [straw 6.04 (5.39 to 6.28) vs. sand 4.19 (3.62 to 5.16)]. At the end of experiment the severity of hock lesions was lower for cows on sand than for cows on straw [sand 0.5 (0.0 to 1.0) vs. straw 1.0 (1.0 to 2.0)]. The improvement in overall hoof health over the observation period was greater for cows kept on sand compared with cows kept on straw [sand -2.00 (-3.75 to -0.25) vs. straw 0.00 (-2.00 to 2.00)]. Straw bedding increased the time that cows spend lying, and cows preferred straw stalls to sand stalls. However, previous experience with sand reduces avoidance of sand stalls. Sand stalls were advantageous for cow cleanliness and health; hock lesions and claw diseases healed more quickly for cows using sand stalls compared with straw.

  3. The effect of floor type on the performance, cleanliness, carcass characteristics and meat quality of dairy origin bulls.

    PubMed

    Murphy, V S; Lowe, D E; Lively, F O; Gordon, A W

    2018-05-01

    The aim of this study was to evaluate the effect of using different floor types to accommodate growing and finishing beef cattle on their performance, cleanliness, carcass characteristics and meat quality. In total, 80 dairy origin young bulls (mean initial live weight 224 kg (SD=28.4 kg)) were divided into 20 blocks with four animals each according to live weight. The total duration of the experimental period was 204 days. The first 101 days was defined as the growing period, with the remainder of the study defined as the finishing period. Cattle were randomly assigned within blocks to one of four floor type treatments, which included fully slatted flooring throughout the entire experimental period (CS); fully slatted flooring covered with rubber strips throughout the entire experimental period (RS); fully slatted flooring during the growing period and moved to a solid floor covered with straw bedding during the finishing period (CS-S) and fully slatted flooring during the growing period and moved to fully slatted flooring covered with rubber strips during the finishing period (CS-RS). Bulls were offered ad libitum grass silage supplemented with concentrates during the growing period. During the finishing period, bulls were offered concentrates supplemented with chopped barley straw. There was no significant effect of floor type on total dry matter intake (DMI), feed conversion ratio, daily live weight gain or back fat depth during the growing and finishing periods. Compared with bulls accommodated on CS, RS and CS-RS, bulls accommodated on CS-S had a significantly lower straw DMI (P<0.01). Although bulls accommodated on CS and CS-S were significantly dirtier compared with those accommodated on RS and CS-RS on days 50 (P<0.05) and 151 (P<0.01), there was no effect of floor type on the cleanliness of bulls at the end of the growing and finishing periods. There was also no significant effect of floor type on carcass characteristics or meat quality. However, bulls accommodated on CS-S had a tendency for less channel, cod and kidney fat (P=0.084) compared with those accommodated on CS, RS and CS-RS. Overall, floor type had no effect on the performance, cleanliness, carcass characteristics or meat quality of growing or finishing beef cattle.

  4. Bioreactor design for successive culture of anchorage-dependent cells operated in an automated manner.

    PubMed

    Kino-Oka, Masahiro; Ogawa, Natsuki; Umegaki, Ryota; Taya, Masahito

    2005-01-01

    A novel bioreactor system was designed to perform a series of batchwise cultures of anchorage-dependent cells by means of automated operations of medium change and passage for cell transfer. The experimental data on contamination frequency ensured the biological cleanliness in the bioreactor system, which facilitated the operations in a closed environment, as compared with that in flask culture system with manual handlings. In addition, the tools for growth prediction (based on growth kinetics) and real-time growth monitoring by measurement of medium components (based on small-volume analyzing machinery) were installed into the bioreactor system to schedule the operations of medium change and passage and to confirm that culture proceeds as scheduled, respectively. The successive culture of anchorage-dependent cells was conducted with the bioreactor running in an automated way. The automated bioreactor gave a successful culture performance with fair accordance to preset scheduling based on the information in the latest subculture, realizing 79- fold cell expansion for 169 h. In addition, the correlation factor between experimental data and scheduled values through the bioreactor performance was 0.998. It was concluded that the proposed bioreactor with the integration of the prediction and monitoring tools could offer a feasible system for the manufacturing process of cultured tissue products.

  5. Low radioactivity material for use in mounting radiation detectors

    NASA Technical Reports Server (NTRS)

    Fong, Marshall; Metzger, Albert E.; Fox, Richard L.

    1988-01-01

    Two materials, sapphire and synthetic quartz, have been found for use in Ge detector mounting assemblies. These materials combine desirable mechanical, thermal, and electrical properties with the radioactive cleanliness required to detect minimal amounts of K, Th, and U.

  6. Adhesion and friction of transition metals in contact with nonmetallic hard materials

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.

    1981-01-01

    Sliding friction experiments were conducted with the metals yttrium, titanium, tantalum, zirconium, vanadium, neodymium, iron, cobalt, nickel, tungsten, platinum, rhenium, ruthenium, and rhodium in sliding contact with single crystal diamond, silicon carbide, pyrolytic boron nitride, and ferrite. Auger electron spectroscopy analysis was conducted with the metals and nonmetals to determine the surface chemistry and the degree of surface cleanliness. The results of the investigation indicate the adhesion and friction of the transition metals in contact with diamond, silicon carbide, boron nitride, and ferrite are related to the relative chemical activity of the metals. The more chemically active the metal, the higher the coefficient of friction and the greater amount of transfer to the nonmetals.

  7. Thermal Analysis of the Vulnerability of the Spacesuit Battery Design to Short-Circuit Conditions (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, G. H.; Chaney, L.; Smith, K.

    2010-04-22

    NREL researchers created a mathematical model of a full 16p-5s spacesuit battery for NASA that captures electrical/thermal behavior during shorts to assess the vulnerability of the battery to pack-internal (cell-external) shorts. They found that relocating the short from battery pack-external (experimental validation) to pack-internal (modeling study) causes substantial additional heating of cells, which can lead to cell thermal runaway. All three layers of the bank-to-bank separator must fail for the pack-internal short scenario to occur. This finding emphasizes the imperative of battery pack assembly cleanliness. The design is tolerant to pack-internal shorts when stored at 0% state of charge.

  8. 40 CFR 80.141 - Interim detergent gasoline program.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) “Carburetor Cleanliness Test Procedure, State-of-the-Art Summary, Report: 1973-1981”, Coordinating Research... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold... who manufacture, supply, or transfer detergent additives or detergent-additized post-refinery...

  9. 21 CFR 110.10 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN MANUFACTURING, PACKING, OR HOLDING HUMAN FOOD General... contamination of food. The methods for maintaining cleanliness include, but are not limited to: (1) Wearing outer garments suitable to the operation in a manner that protects against the contamination of food...

  10. Using the Case Study Method to Treat Several Problems in a Family Indicated for Child Neglect.

    ERIC Educational Resources Information Center

    Lutzker, John R.; And Others

    1984-01-01

    An example of the ecobehavioral perspective is offered of a family referred for child neglect which received a variety of services from one project, including interventions for health maintenance, cleanliness, and personal hygiene. (CL)

  11. Is Exposure to Animal Feces Harmful to Child Nutrition and Health Outcomes? A Multicountry Observational Analysis

    PubMed Central

    Headey, Derek; Nguyen, Phuong; Kim, Sunny; Rawat, Rahul; Ruel, Marie; Menon, Purnima

    2017-01-01

    It has recently been hypothesized that exposure to livestock constitutes a significant risk factor for diarrhea and environmental enteric disorder in young children, which may significantly contribute to undernutrition. To date, though, very little research has documented the extent of exposure to animal feces and whether this exposure is associated with child anthropometry in large samples and diverse settings. This study investigates these issues using data from the Alive and Thrive study conducted in rural areas of Ethiopia, Bangladesh, and Vietnam. These surveys used spot-checks to collect data on proxies of hygiene behaviors such as the cleanliness of mothers, young children, and the homestead environment, including the presence of animal feces. Animal feces were visible in 38–42% of household compounds across the three countries and were positively associated with household livestock ownership and negatively associated with maternal and child cleanliness. One-sided tests from multivariate least squares models for children 6–24 months of age indicate that the presence of animal feces is significantly and negatively associated with child height-for-age z scores in Ethiopia (β = −0.22), Bangladesh (β = −0.13), and in a pooled sample (β = −0.11), but not in Vietnam. There is also suggestive evidence that animal feces may be positively associated with diarrhea symptoms in Bangladesh. The results in this article, therefore, contribute to a growing body of evidence suggesting that animal ownership may pose a significant risk to child nutrition and health outcomes in developing countries. PMID:27994099

  12. Contamination Impact of Station Brush Fire on Cleanroom Facilities

    NASA Technical Reports Server (NTRS)

    Carey, Phil; Blakkolb, Brian

    2010-01-01

    Brush and forest fires, both naturally occurring and anthropogenic in origin, in proximity to space flight hardware processing facilities raise concerns about the threat of contamination resulting from airborne particulate and molecular components of smoke. Perceptions of the severity of the threat are possibly heightened by the high sensitivity of the human sense of smell to some components present in the smoke of burning vegetation.On August 26th, 2009, a brushfire broke out north of Pasadena, California, two miles from the Jet Propulsion Laboratory. The Station Fire destroyed over 160,000 acres, coming within a few hundred yards of JPL. Smoke concentrations on Lab were very heavy over several days. All Lab operations were halted, and measures were taken to protect personnel, critical hardware, and facilities. Evaluation of real-time cleanroom monitoring data, visualinspection of facilities, filter systems, and analysis of surface cleanliness samples revealed facility environments andhardware were minimally effected.Outside air quality easily exceeded Class Ten Million. Prefilters captured most large ash and soot; multi-stage filtration greatly minimized the impact on the HEPA/ULPA filters. Air quality in HEPA filtered spacecraft assembly cleanrooms remained within Class 10,000 specification throughout. Surface cleanliness was inimally affected, as large particles were effectively removed from the airstream, and sub-micron particles have extremely long settling rates. Approximate particulate fallout within facilities was 0.00011% area coverage/day compared to 0.00038% area coverage/day during normal operations. Deposition of condensable airborne components, as measured in real time, peaked at approximately1.0 ng/cm2/day compared to 0.05 ng/cm2/day nominal.

  13. Contamination impact of station brush fire on cleanroom facilities

    NASA Astrophysics Data System (ADS)

    Carey, Philip A.; Blakkolb, Brian K.

    2010-08-01

    Brush and forest fires, both naturally occurring and anthropogenic in origin, in proximity to space flight hardware processing facilities raise concerns about the threat of contamination resulting from airborne particulate and molecular components of smoke. Perceptions of the severity of the threat are possibly heightened by the high sensitivity of the human sense of smell to some components present in the smoke of burning vegetation. On August 26th, 2009, a brushfire broke out north of Pasadena, California, two miles from the Jet Propulsion Laboratory. The Station Fire destroyed over 160,000 acres, coming within a few hundred yards of JPL. Smoke concentrations on Lab were very heavy over several days. All Lab operations were halted, and measures were taken to protect personnel, critical hardware, and facilities. Evaluation of real-time cleanroom monitoring data, visual inspection of facilities, filter systems, and analysis of surface cleanliness samples revealed facility environments and hardware were minimally effected. Outside air quality easily exceeded Class Ten Million. Prefilters captured most large ash and soot; multi-stage filtration greatly minimized the impact on the HEPA/ULPA filters. Air quality in HEPA filtered spacecraft assembly cleanrooms remained within Class 10,000 specification throughout. Surface cleanliness was minimally affected, as large particles were effectively removed from the airstream, and sub-micron particles have extremely long settling rates. Approximate particulate fallout within facilities was 0.00011% area coverage/day compared to 0.00038% area coverage/day during normal operations. Deposition of condensable airborne components, as measured in real time, peaked at approximately 1.0 ng/cm2/day compared to 0.05 ng/cm2/day nominal.

  14. The matron's role in acute National Health Service trusts.

    PubMed

    Gould, Dinah

    2008-10-01

    The aim of this study was to describe how matrons in an acute National Health Service trust perceive and undertake their role since its reconfiguration in 2005 and to investigate their needs for continuing professional development. Matrons returned to acute National Health Service trusts in 2002 to provide a senior, authoritative nursing presence throughout clinical areas. Their function is to promote high standards of clinical care and leadership; ensure that administrative and support services are in place to deliver high standards of care; and provide a visible, accessible and authoritative presence in ward settings. Data were obtained by interview. A qualitative approach using a semi-structured interview schedule was used to obtain data from 22 matrons and the data were subjected to thematic analysis. There were differences in the way that matrons performed their role. They promoted clinical leadership effectively and maintained a high clinical profile. Attempts to promote high standards of cleanliness and infection control were less effective because of the shortcomings of the domestic service. Overall the matron role is proving effective. However, matrons' ability to promote adequate levels of environmental cleanliness and control infection is a cause for concern. IMPLICATIONS FOR NURSING MANAGERS: The study findings suggest that where an existing service is performing poorly, expecting another occupational group to oversee it will not contribute to improvement unless resources can be improved. WHAT THIS PAPER ADDS TO CURRENT KNOWLEDGE: This study has provided an in-depth evaluation of the matron role at a local level. It is to date the most comprehensive study of its kind.

  15. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility.

    PubMed

    Santos-Junior, Aires G; Ferreira, Adriano M; Frota, Oleci P; Rigotti, Marcelo A; Barcelos, Larissa da S; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G; R Furlan, Mara C

    2018-01-01

    Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle ( p =0.007) and the toilet bowl ( p =0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect ( p =0.04). The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems.

  16. Aseptic Handling of the MOMA Mass Spectrometer After Dry Heat Microbial Reduction

    NASA Technical Reports Server (NTRS)

    Lalime, Erin

    2017-01-01

    Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS) is an instrument in the larger MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. As a life-detection instrument on a Mars landing mission, MOMA-MS has very stringent Planetary Protection (PP) bioburden requirements. Within the MOMA instrument suite, the hardware surfaces of the sample path must be cleaned to a level of 0.03 spore/sq m. To meet this requirement, a process called Dry Heat Microbial Reduction (DHMR) is used to decrease the number of viable spores by 4 orders of magnitude. Before DHMR, the hardware is handled using standard cleanroom practices, while after DHMR, all sample path surfaces must be handled aseptically when exposed. Aseptic handling of the sample path involves a number of strategies and protocols including working only in an aseptic ISO class 5 work space, limiting the amount of time of exposure, using sterile garmenting with sterile gloves, and using sterile tools. Before work begins, the aseptic workspace will be tested for bioburden and particle fallout, and all tools that will contact sample path surfaces must be sterilized. During the exposure activity, sterile garments will be worn, sterile tools will be handled in a 2 person set up so that the operator touches only the sterile tool and not the exterior surfaces of the sterile pouch, and the environment will be monitored with active and passive fallout for bioburden and particle levels. Any breach in the planetary protection cleanliness can necessitate repeating DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.

  17. Criteria evaluation for cleanliness testing phase 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meltzer, Michael; Koester, Carolyn; Stefanni, Chris

    1999-02-04

    The Boeing Company (Boeing) contracted with Lawrence Livermore National Laboratory (LLNL) to develop criteria for evaluating the efficacy of its parts cleaning processes. In particular, LLNL and Boeing are attempting to identify levels of contamination that lead to parts failures. Sufficient contamination to cause impairment of anodizing, alodining, painting, or welding operations is considered a "part failure." In the "Phase 0" part of the project that was recently completed, preliminary analyses of aluminum substrates were performed as a first step in determining suitable cleanliness criteria for actual Boeing parts made from this material. A wide spread of contamination levels wasmore » specified for the Phase 0 test coupons, in the hopes of finding a range in which an appropriate cleanliness specification might lie. It was planned that, based on the results of the Phase 0 testing, further more detailed analyses ("Phase 1 testing") would be performed in order to more accurately identify the most appropriate criteria. For the Phase 0 testing, Boeing supplied LLNL with 3" x 6" and 3" x 10" aluminum test panels which LLNL contaminated with measured amounts of typical hydrocarbon substances encountered in Boeing' s fabrication operations. The panels were then subjected by Boeing to normal cleaning procedures, after which they went through one of the following sets of operations: l anodizing and primer painting . alodining (chromating) and primer painting l welding The coatings or welds were then examined by both Boeing and LLNL to determine whether any of the operations were impaired, and whether there was a correlation between contamination level and damage to the parts. The experimental approach and results are described in detail.« less

  18. Implementation of innovative pulsed xenon ultraviolet (PX-UV) environmental cleaning in an acute care hospital.

    PubMed

    Fornwalt, Lori; Riddell, Brad

    2014-01-01

    It is widely acknowledged that the hospital environment is an important reservoir for many of the pathogenic microbes associated with health care-associated infections (HAIs). Environmental cleaning plays an important role in the prevention and containment of HAIs, in patient safety, and the overall experience of health care facilities. New technologies, such as pulsed xenon ultraviolet (PX-UV) light systems are an innovative development for enhanced cleaning and decontamination of hospital environments. A portable PX-UV disinfection device delivers pulsed UV light to destroy microbial pathogens and spores, and can be used in conjunction with manual environmental cleaning. In addition, this technology facilitates thorough disinfection of hospital rooms in 10-15 minutes. The current study was conducted to evaluate whether the introduction of the PX-UV device had a positive impact on patient satisfaction. Satisfaction was measured using the Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) survey. In 2011, prior to the introduction of the PX-UV system, patient HCAHPS scores for cleanliness averaged 75.75%. In the first full quarter after enhanced cleaning of the facility was introduced, this improved to 83%. Overall scores for the hospital rose from 76% (first quarter, 2011) to 87.6% (fourth quarter, 2012). As a result of this improvement, the hospital received 1% of at-risk reimbursement from the inpatient prospective payment system as well as additional funding. Cleanliness of the hospital environment is one of the questions included in the HCAHPS survey and one measure of patient satisfaction. After the introduction of the PX-UV system, the score for cleanliness and the overall rating of the hospital rose from below the fiftieth to the ninety-ninth percentile. This improvement in the patient experience was associated with financial benefits to the hospital.

  19. The effect of honey-coated bandages compared with silver-coated bandages on treatment of malignant wounds-a randomized study.

    PubMed

    Lund-Nielsen, Betina; Adamsen, Lis; Kolmos, Hans Jørn; Rørth, Mikael; Tolver, Anders; Gottrup, Finn

    2011-11-01

    Malignant wounds (MWs) occur in 5-10% of all cancer patients. Malodor and exudation are the most common side effects. The aim was to determine the influence of honey-coated compared with silver-coated bandages on treatment of MWs. Patients were randomly selected to enter either group A (honey-coated bandages) or group B (silver-coated bandages). Parameters were the following: wound size, cleanliness, malodor, exudation, and wound pain. Digital photographs, visual analog scales (VAS), and wound morphology registration were used for measurement at baseline and following the 4-week intervention. Sixty-nine patients with MWs and advanced cancer, aged 47-90 (median 65.6), were included. No statistically significant difference was noted between the groups with respect to wound size, degree of cleanliness, exudation, malodor, and wound pain. There was a median decrease in wound size of 15 cm² and 8 cm² in group A and B, respectively (p = 0.63). Based on post-intervention pooled data from the groups, improvement was seen in 62% of the participants with respect to wound size and in 58% (n = 69) with respect to cleanliness. The VAS score for malodor (p = 0.007) and exudation (p < 0.0001) improved significantly post-intervention. Patients with reduced wound size had a median survival time of 387 days compared with 134 days in patients with no wound reduction (p = 0.003). The use of honey-coated and silver-coated bandages improved the outcome of MWs. No differences were found between the two regimens. Both types of bandages are recommended for use by patients with MWs containing tumor debris and necrosis. 2011 by the Wound Healing Society.

  20. Contamination control program plan for the ultraviolet spectrometer experiment, revision E

    NASA Technical Reports Server (NTRS)

    Gilmore, D. B.

    1972-01-01

    The contamination control program plan delineates the cleanliness requirements to be attained and maintained, and the methods to be utilized, in the fabrication, handling, test, calibration, shipment, pre-installation checkout and installation for the ultraviolet spectrometer experiment prototype, qualification and flight equipment.

  1. The effects of coarse aggregate cleanliness and moisture content on asphalt concrete compactability and moisture susceptibility.

    DOT National Transportation Integrated Search

    2011-12-31

    Twelve field projects were studied where forty-four locations were evaluated to assess the cause or : causes of asphalt concrete that exhibits tender zone characteristics (i.e. instability during compaction) and to : investigate the tendency of...

  2. Transfer of Values in the Turkish and Western Children's Literary Works: Character Education in Turkey

    ERIC Educational Resources Information Center

    Karatay, Halit

    2011-01-01

    In this paper, the occurrence frequency of the values "justice, family union, independence, peace, scientificality, diligence, cooperation, sensitivity, honesty, aesthetics, tolerance, hospitality, freedom, wellness, respect, affection, responsibility, cleanliness, patriotism, benevolence" which the Ministry of Education requires that…

  3. Sabbatical Report: Results of a Survey of Library Microforms Facilities.

    ERIC Educational Resources Information Center

    McIntosh, Melinda C.

    1987-01-01

    Highlights findings on the status of academic library microforms facilities in the United States and Canada based on visits to 11 libraries. Topics covered include administration, personnel, collection access and storage, classification, acquisition, circulation, indexes, hours, facilities, signage, equipment, photocopying, cleanliness, vandalism,…

  4. Genesis Spacecraft Science Canister Preliminary Inspection and Cleaning

    NASA Technical Reports Server (NTRS)

    Hittle, J. D.; Calaway, M. J.; Allton, J. H.; Warren, J. L.; Schwartz, C. M.; Stansbery, E. K.

    2006-01-01

    The Genesis science canister is an aluminum cylinder (75 cm diameter and 35 cm tall) hinged at the mid-line for opening. This canister was cleaned and assembled in an ISO level 4 (Class 10) clean room at Johnson Space Center (JSC) prior to launch. The clean solar collectors were installed and the canister closed in the cleanroom to preserve collector cleanliness. The canister remained closed until opened on station at Earth-Sun L1 for solar wind collection. At the conclusion of collection, the canister was again closed to preserve collector cleanliness during Earth return and re-entry. Upon impacting the dry Utah lakebed at 300 kph the science canister integrity was breached. The canister was returned to JSC. The canister shell was briefly examined, imaged, gently cleaned of dust and packaged for storage in anticipation of future detailed examination. The condition of the science canister shell noted during this brief examination is presented here. The canister interior components were packaged and stored without imaging due to time constraints.

  5. Mir Environmental Effects Payload and Returned Mir Solar Panel Cleanliness

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Humes, Donald H.; Kinard, William H.

    2000-01-01

    The MIR Environmental Effects Payload (MEEP) was attached to the Docking Module of the MIR space station for 18 months during calendar years 1996 and 1997 (March 1996, STS 76 to October 1997, STS 86). A solar panel array with more than 10 years space exposure was removed from the MIR core module in November 1997, and returned to Earth in January, 1998, STS 89. MEEP and the returned solar array are part of the International Space Station (ISS) Risk Mitigation Program. This space flight hardware has been inspected and studied by teams of space environmental effects (SEE) investigators for micrometeoroid and space debris effects, space exposure effects on materials, and electrical performance. This paper reports changes in cleanliness of parts of MEEP and the solar array due to the space exposures. Special attention is given to the extensive water soluble residues deposited on some of the flight hardware surfaces. Directionality of deposition and chemistry of these residues are discussed.

  6. Evaluation of control parameters for Spray-In-Air (SIA) aqueous cleaning for shuttle RSRM hardware

    NASA Technical Reports Server (NTRS)

    Davis, S. J.; Deweese, C. D.

    1995-01-01

    HD-2 grease is deliberately applied to Shuttle Redesigned Solid Rocket Motor (RSRM) D6AC steel hardware parts as a temporary protective coating for storage and shipping. This HD-2 grease is the most common form of surface contamination on RSRM hardware and must be removed prior to subsequent surface treatment. Failure to achieve an acceptable level of cleanliness (HD-2 calcium grease removal) is a common cause of defect incidence. Common failures from ineffective cleaning include poor adhesion of surface coatings, reduced bond performance of structural adhesives, and failure to pass cleanliness inspection standards. The RSRM hardware is currently cleaned and refurbished using methyl chloroform (1,1,1-trichloroethane). This chlorinated solvent is mandated for elimination due to its ozone depleting characteristics. This report describes an experimental study of an aqueous cleaning system (which uses Brulin 815 GD) as a replacement for methyl chloroform. Evaluation of process control parameters for this cleaner are discussed as well as cleaning mechanisms for a spray-in-air process.

  7. Effect of Aquatine Endodontic Cleanser on smear layer removal in the root canals of ex vivo human teeth.

    PubMed

    Garcia, Faustino; Murray, Peter E; Garcia-Godoy, Franklin; Namerow, Kenneth N

    2010-01-01

    The purpose of this study was to measure and compare the root canal cleanliness and smear layer removal effectiveness of Aquatine Endodontic Cleanser (Aquatine EC) when used as an endodontic irrigating solution in comparison with 6% sodium hypochlorite (NaOCl). Forty-five human teeth were randomly allocated to five treatment groups; the pulp chamber was accessed, cleaned, and shaped by using ProTaper and ProFile rotary instrumentation to an ISO size #40. The teeth were then processed for scanning electron microscopy, and the root canal cleanliness and removal of smear layer were examined. The most effective removal of smear layer occurred with Aquatine EC and NaOCl, both with a rinse of EDTA. Aquatine EC appears to be the first hypochlorous acid approved by the FDA to be a possible alternative to the use of NaOCl as an intracanal irrigant. Further research is needed to identify safer and more effective alternatives to the use of NaOCl irrigation in endodontics.

  8. Effects of Ultra-Clean and centrifugal filtration on rolling-element bearing life

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Moyer, D. W.; Needelman, W. M.

    1981-01-01

    Fatigue tests were conducted on groups of 65-millimeter bore diameter deep-groove ball bearings in a MIL-L-23699 lubricant under two levels of filtration. In one test series, the oil cleanliness was maintained at an exceptionally high level (better than a class "000" per NAS 1638) with a 3 micron absolute barrier filter. These tests were intended to determine the "upper limit" in bearing life under the strictest possible lubricant cleanliness conditions. In the tests using a centrifugal oil filter, contaminants of the type found in aircraft engine filters were injected into the filters' supply line at 125 milligrams per bearing-hour. "Ultra-clean" lubrication produced bearing fatigue lives that were approximately twice that obtained in previous tests with contaminated oil using 3 micron absolute filtration and approximately three times that obtained with 49 micron filtration. It was also observed that the centrifugal oil filter had approximately the same effectiveness as a 30 micron absolute filter in preventing bearing surface damage.

  9. The Search for Nonflammable Solvent Alternatives for Cleaning Aerospace Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Mitchell, Mark A.; Lowrey, Nikki

    2012-01-01

    To obtain a high degree of cleanliness without risk of corrosion or hazardous reactivity, hydrochlorofluorocarbon (HCFC)-225 is used for cleaning and cleanliness verification of oxygen system components used on NASA fs bipropellant launch vehicles, associated test stands and support equipment. HCFC-225 is a Class II Ozone Depleting Substance (ODS ]II) that was introduced to replace chlorofluorocarbon (CFC)-113, a Class I ODS solvent that is now banned. To meet environmental regulations to eliminate the use of ozone depleting substances, a replacement solvent is required for HCFC ]225 that is effective at removing oils, greases, and particulate from large oxygen system components, is compatible with materials used in the construction of these systems, and is nonflammable and non ]reactive in enriched oxygen environments. A solvent replacement is also required for aviator fs breathing oxygen systems and other related equipment currently cleaned and verified with HCFC ]225 and stockpiled CFC -113. Requirements and challenges in the search for nonflammable replacement solvents are discussed.

  10. Stall dimensions and the prevalence of lameness, injury, and cleanliness on 317 tie-stall dairy farms in Ontario

    PubMed Central

    2005-01-01

    Abstract The study objectives were to provide a province-wide description of stall dimensions and the aspects of cattle welfare linked to stall design in the tie-stall industry. Data on stall design; stall dimensions; and the prevalence of lameness, injury, and hind limb and udder cleanliness in lactating dairy cattle were collected from a sample of 317 tie-stall farms across Ontario. The majority of the study farms (90%) had stalls with dimensions (length, width, tie-chain length, and tie rail height) that were less than the current recommendations. This may explain, in part, the prevalence of lameness measured as the prevalence of back arch (3.2%) and severe hind claw rotation (23%), hock lesions (44%), neck lesions (3.8%), broken tails (3%), dirty hind limbs (23%), and dirty udders (4.6%). Veterinarians and producers may use this information to compare farms with the industry averages and target areas in need of improvement. PMID:16454382

  11. Plasma surface cleaning using microwave plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, C.C.; Haselton, H.H.; Nelson, W.D.

    1993-11-01

    In a microwave electron cyclotron resonance (ECR) plasma source, reactive plasmas of oxygen and its mixture with argon are used for plasma-cleaning experiments. Aluminum test samples (0.95 {times} 1.9 cm) were coated with thin films ({le} 20 {mu}m in thickness) of Shell Vitrea oil and cleaned by using such reactive plasmas. The plasma cleaning was done in various discharge conditions with fixed microwave power, rf power, biased potential, gas pressures (0.5 and 5 mtorr), and operating time up to 35 min. The status of plasma cleaning has been monitored by using mass spectroscopy. Mass loss of the samples after plasmamore » cleaning was measured to estimate cleaning rates. Measured clean rates of low pressure (0.5 mtorr) argon/oxygen plasmas were as high as 2.7 {mu}/min. X-ray photoelectron spectroscopy was used to determine cleanliness of the sample surfaces and confirm the effectiveness of plasma cleaning in achieving atomic levels of surface cleanliness. In this paper, significant results are reported and discussed.« less

  12. Do adjuvants add to the efficacy and tolerance of bowel preparations? A meta-analysis of randomized trials.

    PubMed

    Restellini, Sophie; Kherad, Omar; Menard, Charles; Martel, Myriam; Barkun, Alan N

    2018-02-01

    BACKGROUND AND STUDY AIMS : Recommendations on adjuvant use with bowel preparations remain disparate. We performed a meta-analysis determining the clinical impact of adding an adjuvant to polyethylene glycol (PEG), sodium phosphate, picosulfate (PICO), or oral sulfate solutions (OSS)-based regimens.  Systematic searches were made of MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials from January 1980 to April 2016 that assessed preparations with or without adjuvants, given in split and non-split dosing, and PEG high- (> 3 L) or low-dose (≤ 2 L) regimens. Bowel cleansing efficacy was the primary outcome. Secondary outcomes included patient willingness to repeat the procedure, and polyp and adenoma detection rates.  Of 3093 citations, 77 trials fulfilled the inclusion criteria. Overall, addition of an adjuvant compared with no adjuvant, irrespective of the type of preparation and mode of administration, yielded improvements in bowel cleanliness (odds ratio [OR] 1.23 [1.01 - 1.51]) without greater willingness to repeat (OR 1.40 [0.91 - 2.15]). Adjuvants combined with high-dose PEG significantly improved colon cleansing (OR 1.96 [1.32 - 2.94]). The odds for achieving adequate preparation with low-dose PEG with an adjuvant were not different to high-dose PEG alone (OR 0.95 [0.73 - 1.22]), but yielded improved tolerance (OR 3.22 [1.85 - 5.55]). However, split high-dose PEG yielded superior cleanliness to low-dose PEG with adjuvants (OR 2.53 [1.25 - 5.13]). No differences were noted for OSS and PICO comparisons, or for any products regarding polyp or adenoma detection rates.  Critical heterogeneity precludes firm conclusion on the impact of adjuvants with existing bowel preparations. Additional research is required to better characterize the methods of administration and resulting roles of adjuvants in an era of split-dosing. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Overview of current capabilities and research and technology developments for planetary protection

    NASA Astrophysics Data System (ADS)

    Frick, Andreas; Mogul, Rakesh; Stabekis, Pericles; Conley, Catharine A.; Ehrenfreund, Pascale

    2014-07-01

    The pace of scientific exploration of our solar system provides ever-increasing insights into potentially habitable environments, and associated concerns for their contamination by Earth organisms. Biological and organic-chemical contamination has been extensively considered by the COSPAR Panel on Planetary Protection (PPP) and has resulted in the internationally recognized regulations to which spacefaring nations adhere, and which have been in place for 40 years. The only successful Mars lander missions with system-level “sterilization” were the Viking landers in the 1970s. Since then different cleanliness requirements have been applied to spacecraft based on their destination, mission type, and scientific objectives. The Planetary Protection Subcommittee of the NASA Advisory Council has noted that a strategic Research & Technology Development (R&TD) roadmap would be very beneficial to encourage the timely availability of effective tools and methodologies to implement planetary protection requirements. New research avenues in planetary protection for ambitious future exploration missions can best be served by developing an over-arching program that integrates capability-driven developments with mission-driven implementation efforts. This paper analyzes the current status concerning microbial reduction and cleaning methods, recontamination control and bio-barriers, operational analysis methods, and addresses concepts for human exploration. Crosscutting research and support activities are discussed and a rationale for a Strategic Planetary Protection R&TD Roadmap is outlined. Such a roadmap for planetary protection provides a forum for strategic planning and will help to enable the next phases of solar system exploration.

  14. Proceedings of the 1996 Windsor workshop on alternative fuels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-10-01

    This document contains information which was presented at the 1996 Windsor Workshop on Alternative Fuels. Topics include: international links; industry topics and infrastructure issues; propane; engine developments; the cleanliness of alternative fuels; heavy duty alternative fuel engines; California zev commercialization efforts; and in-use experience.

  15. 7 CFR 58.130 - Health.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Health. 58.130 Section 58.130 Agriculture Regulations... Plants Approved for USDA Inspection and Grading Service 1 Personnel, Cleanliness and Health § 58.130 Health. No person afflicted with a communicable disease shall be permitted in any room or compartment...

  16. 7 CFR 58.130 - Health.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Health. 58.130 Section 58.130 Agriculture Regulations... Plants Approved for USDA Inspection and Grading Service 1 Personnel, Cleanliness and Health § 58.130 Health. No person afflicted with a communicable disease shall be permitted in any room or compartment...

  17. 7 CFR 58.130 - Health.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Health. 58.130 Section 58.130 Agriculture Regulations... Plants Approved for USDA Inspection and Grading Service 1 Personnel, Cleanliness and Health § 58.130 Health. No person afflicted with a communicable disease shall be permitted in any room or compartment...

  18. 7 CFR 58.130 - Health.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Health. 58.130 Section 58.130 Agriculture Regulations... Plants Approved for USDA Inspection and Grading Service 1 Personnel, Cleanliness and Health § 58.130 Health. No person afflicted with a communicable disease shall be permitted in any room or compartment...

  19. 7 CFR 58.130 - Health.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Health. 58.130 Section 58.130 Agriculture Regulations... Plants Approved for USDA Inspection and Grading Service 1 Personnel, Cleanliness and Health § 58.130 Health. No person afflicted with a communicable disease shall be permitted in any room or compartment...

  20. 21 CFR 600.11 - Physical establishment, equipment, animals, and care.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Physical establishment, equipment, animals, and... designed and constructed to permit thorough cleaning and, where possible, inspection for cleanliness. All... each culture is designed to withstand handling without breaking. (3) Work with spore-forming...

  1. Environmental control and waste management system design concept

    NASA Technical Reports Server (NTRS)

    Gandy, A. R.

    1974-01-01

    Passive device contains both solid and liquid animal waste matter for extended period without being cleaned and without contaminating animal. Constant airflow dries solid waste and evaporates liquid matter. Technique will maintain controlled atmospheric conditions and cage cleanliness during periods of 6 months to 1 year.

  2. Automatic Flushing Unit With Cleanliness Monitor

    NASA Technical Reports Server (NTRS)

    Hildebrandt, N. E.

    1982-01-01

    Liquid-level probe kept clean, therefore at peak accuracy, by unit that flushes probe with solvent, monitors effluent for contamination, and determines probe is particle-free. Approach may be adaptable to industrial cleaning such as flushing filters and pipes, and ensuring that manufactured parts have been adequately cleaned.

  3. 9 CFR 416.5 - Employee hygiene.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Employee hygiene. 416.5 Section 416.5 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE REGULATORY... Employee hygiene. (a) Cleanliness. All persons working in contact with product, food-contact surfaces, and...

  4. 77 FR 20691 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-05

    ... Locomotives 4001-4016, at 5 years of age, ``revealed exceptional cleanliness and no issues were noted which... for their request. All communications concerning these proceedings should identify the appropriate.... Communications received by May 21, 2012 will be considered by FRA before final action is taken. Comments received...

  5. Improving Toilet-Use (Encopresis) in a Nine-Year-Old Male through Full-Cleanliness Training and Token Reinforcement.

    ERIC Educational Resources Information Center

    Akande, Adebowale

    1993-01-01

    Describes assessment and successful treatment of a preadolescent with erratic toileting behavior and related social skills difficulties. Treatment included monitoring of bowel movements, using a star chart, and applying rewards as positive reinforcement of acceptable behavior. (HTH)

  6. 28 CFR 551.1 - Policy.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Policy. 551.1 Section 551.1 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT MISCELLANEOUS Grooming § 551.1... personal cleanliness and dress in keeping with standards of good grooming and the security, good order, and...

  7. Addressing Machining Issues for the Intermetallic Compound 60-NITINOL

    NASA Technical Reports Server (NTRS)

    Stanford, Malcolm K.; Wozniak, Walter A.; McCue, Terry R.

    2012-01-01

    60-NITINOL (60 wt.% Ni - 40 wt.% Ti) is being studied as a material for advanced aerospace components. Frequent wire breakage during electrical-discharge machining of this material was investigated. The studied material was fabricated from hot isostatically pressed 60-NITINOL powder obtained through a commercial source. Bulk chemical analysis of the material showed that the composition was nominal but had relatively high levels of certain impurities, including Al and O. It was later determined that Al2O3 particles had contaminated the material during the hot isostatic pressing procedure and that these particles were the most likely cause of the wire breakage. The results of this investigation highlight the importance of material cleanliness to its further implementation.

  8. Optimization of multimagnetometer systems on a spacecraft

    NASA Technical Reports Server (NTRS)

    Neubauer, F. M.

    1975-01-01

    The problem of optimizing the position of magnetometers along a boom of given length to yield a minimized total error is investigated. The discussion is limited to at most four magnetometers, which seems to be a practical limit due to weight, power, and financial considerations. The outlined error analysis is applied to some illustrative cases. The optimal magnetometer locations, for which the total error is minimum, are computed for given boom length, instrument errors, and very conservative magnetic field models characteristic for spacecraft with only a restricted or ineffective magnetic cleanliness program. It is shown that the error contribution by the magnetometer inaccuracy is increased as the number of magnetometers is increased, whereas the spacecraft field uncertainty is diminished by an appreciably larger amount.

  9. School Safety and Security.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento.

    This document offers additional guidelines for school facilities in California in the areas of safety and security, lighting, and cleanliness. It also offers a description of technology resources available on the World Wide Web. On the topic of safety and security, the document offers guidelines in the areas of entrances, doors, and controlled…

  10. Hamburger Science

    ERIC Educational Resources Information Center

    Trent, Ann

    2004-01-01

    While babysitting or preparing home meals, young people (and adults too) sometimes overlook cleanliness procedures. One of the first employment opportunities for teenagers is often in a fast-food restaurant where the safe handling and proper cooking of foods is essential. To teach students about food safety practices, the U.S. Food and Drug…

  11. Suck It up

    ERIC Educational Resources Information Center

    Jansik, Dave

    2008-01-01

    Benchmarks for cleanliness can be subjective. Now that LEED (Leadership in Energy and Environmental Design) standards are gaining a foothold among facilities management and building professionals, there is a benchmark to strive for and a high-quality vacuum is a key part of the equation. LEED is a nationally accepted benchmark and blueprint for…

  12. SCHOOL CARPET--DOES IT MAKE SENSE.

    ERIC Educational Resources Information Center

    NABORS, ELIZABETH

    DEALS WITH THE ECONOMICS OF COMMERCIAL CARPETING INSTALLATIONS IN SCHOOLS. SHAKER HIGH SCHOOL IN NEW YORK WAS THE FIRST PUBLIC HIGH SCHOOL TO BE CARPETED. THE INDUSTRIAL SANITATION COUNSELORS OF LOUISVILLE, KENTUCKY, WAS SELECTED TO CONDUCT MAINTENANCE STUDIES WHICH INCLUDED METHODS, CLEANING COSTS, AND LEVELS OF CLEANLINESS QUALITY. THE OBJECTIVE…

  13. Project CLEAN: Safe, Sanitary School Restrooms. Fastback.

    ERIC Educational Resources Information Center

    Keating, Tom

    After introducing the problem of unsafe, dirty public school restrooms, this publication describes Project CLEAN (Citizens, Learners, and Educators Against Neglect), an effort to improve the safety, cleanliness, and hygiene of student restrooms in public schools. The Project builds a five-step, school-by-school communication process that includes:…

  14. Waste Not

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2010-01-01

    When schools and universities look at saving energy in their facilities, they are likely to review the efficiency of their heating and cooling systems, or the quality of their building envelopes. When facility managers focus attention on school bathrooms, they are more likely to consider issues such as cleanliness and safety as more critical than…

  15. The Importance of Interior Design Elements as They Relate to Student Outcomes.

    ERIC Educational Resources Information Center

    Tanner, C. Kenneth; Langford, Ann

    This study investigated the following questions: (1) "What are the perceptions that elementary school principals have concerning the influence of interior design elements such as floor and wall coverings, lighting, flexibility, acoustics, color, texture, patterns, cleanliness, and maintenance on student achievement, teacher retention, and student…

  16. A Study of 8 Fundamental Moral Characteristics among Thai Undergraduate Students

    ERIC Educational Resources Information Center

    Ngammuk, Patariya

    2011-01-01

    The objective of this study is to explore the eight fundamental moral characteristics of undergraduate students in order to benefit instructional model development. The eight moral characteristics are diligence, frugality, honesty, discipline, politeness, cleanliness, unity and generosity. The study findings rank these eight moral characteristics…

  17. 24 CFR 3280.802 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... supply. (15) Distribution panelboard means a single panel or a group of panel units designed for assembly...) Panelboard means a single panel or group of panel units designed for assembly in the form of a single panel... treatment of air so as to control simultaneously its temperature, humidity, cleanliness, and distribution to...

  18. Healthy Swimming Is a Partnership Effort

    ERIC Educational Resources Information Center

    Grosse, Susan J.

    2009-01-01

    While one cannot control the water chemistry, he/she can control personal hygiene and facility cleanliness. Giardia and cryptosporidium (crypto) are only two of the many recreational water illnesses (RWIs) that can turn happy swim memories into serious illness situations. In this article, the author discusses three factors that determine how…

  19. Personal Skills. Facilitator's Skill Packets 1-7. Social Skills Training.

    ERIC Educational Resources Information Center

    Model Classrooms, Bellevue, WA.

    This document contains the following seven facilitators' skill packets on personal skills: (1) personal hygiene; (2) personal appearance; (3) locker hygiene; (4) dorm cleanliness; (5) punctuality and attendance; (6) responding to supervision; and (7) teamwork. Each packet contains the following sections: definition of personal skills; objective;…

  20. Comparative study of two bowel preparation regimens for colonoscopy: senna tablets vs sodium phosphate solution.

    PubMed

    Kositchaiwat, Savit; Suwanthanmma, Weerapat; Suvikapakornkul, Ronnarat; Tiewthanom, Vaewvadee; Rerkpatanakit, Prisna; Tinkornrusmee, Chaowalitr

    2006-09-14

    To compare the efficacy and acceptance of senna tablet and sodium phosphate solution for bowel preparation before colonoscopy. One hundred and thirty four patients, who needed elective colonoscopy, were randomly allocated to take 180 mg senna tablet or 95 mL sodium phosphate solution on the day before colonoscopy. The efficacies of both laxatives were compared using the mean difference of colon-cleanliness score of the rectum, sigmoid segments, descending colon, transverse colon and cecum. The scores were rated by two observers who were blinded to the laxatives administered. The higher score means that the colon is cleaner. The efficacy of both laxatives were equivalent if the 95% confidence interval of the mean difference of the score of colon lie within -1 to +1. On intention-to-treat analysis, the mean cleanliness scores in the four segments of colon except the cecum were higher in the sodium phosphate group than those in senna group (7.9 +/- 1.7 vs 8.3 +/- 1.5, 8.0 +/- 1.8 vs 8.5 +/- 1.4, 7.9 +/- 2.0 vs 8.5 +/- 1.3, 7.9 +/- 2.0 vs 8.2 +/- 1.4 and 7.2 +/- 1.7 vs 6.9 +/- 1.4, respectively). The 95% confidence intervals (95% CI) of mean difference in each segment of colon were not found to lie within 1 point which indicated that their efficacies were not equivalent. The taste of senna was better than sodium phosphate solution. Also, senna had fewer side effects. The efficacy of senna is not equivalent to sodium phosphate solution in bowel preparation for colonoscopy, but senna may be considered an alternative laxative.

  1. Comparative study of two bowel preparaton regimens for colonoscopy: Senna tablets vs sodium phosphate solution

    PubMed Central

    Kositchaiwat, Savit; Suwanthanmma, Weerapat; Suvikapakornkul, Ronnarat; Tiewthanom, Vaewvadee; Rerkpatanakit, Prisna; Tinkornrusmee, Chaowalitr

    2006-01-01

    AIM: To compare the efficacy and acceptance of senna tablet and sodium phosphate solution for bowel preparation before colonoscopy. METHODS: One hundred and thirty four patients, who needed elective colonoscopy, were randomly allocated to take 180 mg senna tablet or 95 mL sodium phosphate solution on the day before colonoscopy. The efficacies of both laxatives were compared using the mean difference of colon-cleanliness score of the rectum, sigmoid segments, descending colon, transverse colon and cecum. The scores were rated by two observers who were blinded to the laxatives administered. The higher score means that the colon is cleaner. The efficacy of both laxatives were equivalent if the 95% confidence interval of the mean difference of the score of colon lie within -1 to +1. RESULTS: On intention-to-treat analysis, the mean cleanliness scores in the four segments of colon except the cecum were higher in the sodium phosphate group than those in senna group (7.9 ± 1.7 vs 8.3 ± 1.5, 8.0 ± 1.8 vs 8.5 ± 1.4, 7.9 ± 2.0 vs 8.5 ± 1.3, 7.9 ± 2.0 vs 8.2 ± 1.4 and 7.2 ± 1.7 vs 6.9 ± 1.4, respectively). The 95% confidence intervals (95% CI) of mean difference in each segment of colon were not found to lie within 1 point which indicated that their efficacies were not equivalent. The taste of senna was better than sodium phosphate solution. Also, senna had fewer side effects. CONCLUSION: The efficacy of senna is not equivalent to sodium phosphate solution in bowel preparation for colonoscopy, but senna may be considered an alternative laxative. PMID:17006995

  2. Hospital outpatient perceptions of the physical environment of waiting areas: the role of patient characteristics on atmospherics in one academic medical center.

    PubMed

    Tsai, Chun-Yen; Wang, Mu-Chia; Liao, Wei-Tsen; Lu, Jui-Heng; Sun, Pi-Hung; Lin, Blossom Yen-Ju; Breen, Gerald-Mark

    2007-12-05

    This study examines hospital outpatient perceptions of the physical environment of the outpatient waiting areas in one medical center. The relationship of patient characteristics and their perceptions and needs for the outpatient waiting areas are also examined. The examined medical center consists of five main buildings which house seventeen primary waiting areas for the outpatient clinics of nine medical specialties: 1) Internal Medicine; 2) Surgery; 3) Ophthalmology; 4) Obstetrics-Gynecology and Pediatrics; 5) Chinese Medicine; 6) Otolaryngology; 7) Orthopedics; 8) Family Medicine; and 9) Dermatology. A 15-item structured questionnaire was developed to rate patient satisfaction covering the four dimensions of the physical environments of the outpatient waiting areas: 1) visual environment; 2) hearing environment; 3) body contact environment; and 4) cleanliness. The survey was conducted between November 28, 2005 and December 8, 2005. A total of 680 outpatients responded. Descriptive, univariate, and multiple regression analyses were applied in this study. All of the 15 items were ranked as relatively high with a range from 3.362 to 4.010, with a neutral score of 3. Using a principal component analysis' summated scores of four constructed dimensions of patient satisfaction with the physical environments (i.e. visual environment, hearing environment, body contact environment, and cleanliness), multiple regression analyses revealed that patient satisfaction with the physical environment of outpatient waiting areas was associated with gender, age, visiting frequency, and visiting time. Patients' socio-demographics and context backgrounds demonstrated to have effects on their satisfaction with the physical environment of outpatient waiting areas. In addition to noticing the overall rankings for less satisfactory items, what should receive further attention is the consideration of the patients' personal characteristics when redesigning more comfortable and customized physical environments of waiting areas.

  3. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility

    PubMed Central

    Santos-Junior, Aires G.; Ferreira, Adriano M.; Frota, Oleci P.; Rigotti, Marcelo A.; Barcelos, Larissa da S.; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G.; R. Furlan, Mara C.

    2018-01-01

    Background: Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. Aims: To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. Method: The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Results: Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle (p=0.007) and the toilet bowl (p=0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect (p=0.04). Conclusion: The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. Relevance to Clinical Practice: The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems. PMID:29643951

  4. The habitus of hygiene: discourses of cleanliness and infection control in nursing work.

    PubMed

    Brown, Brian; Crawford, Paul; Nerlich, Brigitte; Koteyko, Nelya

    2008-10-01

    This paper reports upon a qualitative interview study of 22 matrons, infection control staff and operating theatre staff who were questioned about their working lives and the role they played in the control of healthcare acquired infections such as MRSA virus in the UK. A theoretical framework drawing upon the work of Bourdieu is deployed as his notion of habitus captures the combination of practical work, physical disposition and ways of looking at the world which are displayed in the interview accounts of labour in the healthcare field. Three themes emerged from the analysis: first, the 'securitization' of healthcare work, concerned with control, supervision, 'making sure' and the management of risk through inspection, audit and the exercise of responsibility; second, the sense of struggle against doctors who were seen to represent a threat to the carefully organized boundaries, through such alleged violations as not washing their hands, wandering between theatre and canteen areas in soiled clothing and thinking the rules did not apply to them; third, in a 'back to basics' theme participants emphasised the fundamentals of what they saw to be nursing work and were concerned with cleanliness and practically based training -- the habitus of hygiene itself. This was formulated in nostalgic terms with reminiscences about basic training earlier in the participants' careers. The preoccupation with hygiene and its 'basic' processes can be seen as a way of managing uncertainty, accumulating a certain kind of symbolic capital and constructing and maintaining boundaries in the healthcare field. It also makes for self-governing, self-exploiting individuals who accrue responsibility to themselves for implementing the 'habitus of hygiene'.

  5. [Bacterial contamination of mobile phones shared in hospital wards and the consciousness and behavior of nurses about biological cleanliness].

    PubMed

    Morioka, Ikuharu; Tabuchi, Yuna; Takahashi, Yuko; Oda, Yuriko; Nakai, Masami; Yanase, Aki; Watazu, Chiyoko

    2011-01-01

    The purpose of this study was to clarify the contamination of mobile phones shared in hospital wards and its relationship with the consciousness and behavior of nurses about biological cleanliness. Samples from mobile phones were cultured to detect viable bacteria (n=110) and Staphylococcus aureus (n=54). A questionnaire survey was conducted on 110 nurses carrying mobile phones on the day of sampling. Viable bacteria were detected on 79.1% of the mobile phones, whereas S. aureus was detected on 68.6%. All the nurses were aware of hand washing with water or alcohol after regular work, but 33.6% of the nurses were not conscious of hand washing with water or alcohol after using a mobile phone. There was a significant positive relationship between the frequency of using mobile phones and the number of hand washings with water or alcohol. A significant negative relationship was found between the detection of viable bacteria and the number of hand washings with alcohol. The results of logistic regression analysis showed that the detection of viable bacteria was related significantly with the number of hand washings with alcohol (Odds ratio, 0.350; 95%CI, 0.143-0.857) and that the detection of S. aureus was related significantly with the frequency of using mobile phones (Odds ratio, 0.183; 95%CI, 0.036-0.933). It is important to be conscious of the fact that mobile phones shared in hospital wards are easily contaminated. Because hand washing with water or alcohol prevents the contamination of the mobile phones, nurses should take standard precautions after using mobile phones.

  6. Guidelines for qualifying cleaning and verification materials

    NASA Technical Reports Server (NTRS)

    Webb, D.

    1995-01-01

    This document is intended to provide guidance in identifying technical issues which must be addressed in a comprehensive qualification plan for materials used in cleaning and cleanliness verification processes. Information presented herein is intended to facilitate development of a definitive checklist that should address all pertinent materials issues when down selecting a cleaning/verification media.

  7. 46 CFR 56.95-10 - Type and extent of examination required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... necessary by the Officer in Charge, Marine Inspection. In such cases a method of testing satisfactory to the... performance, particularly in field welding where conditions such as position, ambient temperatures, and cleanliness are not as readily controlled as in shop welding. It is to be employed whenever an Officer in...

  8. Listeria monocytogenes persistence and transfer to cantaloupes in the packing environment is affected by equipment surface type and cleanliness

    USDA-ARS?s Scientific Manuscript database

    Cantaloupes have frequently been contaminated with bacterial pathogens and caused several high profile outbreaks over the years. In 2011, Rocky Ford cantaloupes contaminated with Listeria monocytogenes sickened 147 people and resulted in 33 fatalities, making it the deadliest foodborne outbreak in t...

  9. Steels For Rolling-Element Bearings

    NASA Technical Reports Server (NTRS)

    Zaretsky, Erwin V.

    1988-01-01

    Bearing lives increased by attention to details of processing and applications. NASA technical memorandum discusses selection of steels for long-life rolling-element bearings. After brief review of advances in manufacturing, report discusses effect of cleanliness of bearing material on fatigue in rolling element. Also discusses fracture toughnesses of through-hardened and case-hardened materials.

  10. Energy conversion research and development with diminiodes

    NASA Technical Reports Server (NTRS)

    Morris, J. F.

    1974-01-01

    Diminiodes are variable-gap cesium diodes with plane miniature guarded electrodes. These converters allow thermionic evaluations of tiny pieces of rare solids. In addition to smallness, diminiode advantages comprise simplicity, precision, fabrication ease, parts interchangeability, cleanliness, full instrumentation, direct calibration, ruggedness, and economy. Diminiodes with computerized thermionic performance mapping make electrode screening programs practical.

  11. The human dimensions of urban greenways: planning for recreation and related experiences

    Treesearch

    Paul H. Gobster; Lynne M. Westpahl

    2004-01-01

    In this paper, we summarize findings from a series of interrelated studies that examine an urban greenway, the 150 mile Chicago River corridor in Chicago, USA, from multiple perspectives, stakeholder viewpoints, and methodological techniques. Six interdependent "human dimensions" of greenways are identified in the studies: cleanliness, naturalness, aesthetics...

  12. Kids and Manners - A Ticket to Success. Kindergarten-6th.

    ERIC Educational Resources Information Center

    Cunningham, Patricia; And Others

    Arranged into six parts, the booklet offers practical and motivating techniques for teaching elementary school students the basic rules of etiquette. The areas of general etiquette, cleanliness, introductions, table manners, telephoning, and thank you notes are included. Each section contains simple guidelines on how to act and react in social…

  13. Early Childhood Safety Checklist #3: Kitchen and Food Preparation and Storage Areas.

    ERIC Educational Resources Information Center

    Aronson, Susan S.

    1994-01-01

    This checklist of 24 specific health and safety concerns dealing with kitchen and food preparation storage areas can be used by day-care staff to identify and correct hazardous conditions. Areas of concern include hand washing, refrigeration, cooking, trash disposal, cleanliness, fire safety, burn hazards, and adult supervision. (MDM)

  14. Training for QSC: How McDonald's Makes Library Managers.

    ERIC Educational Resources Information Center

    Aycock, Anthony

    2001-01-01

    Written by a former McDonald's manager who earned a master's degree in library science, this article describes how "QSC"--quality, services, and cleanliness--can be applied to libraries in the same way it is used by restaurants. Argues that libraries are simply businesses that cater to customers. (Contains 42 references.) (NB)

  15. Lunar Reconnaissance Orbiter Contamination Sensitivity Training

    NASA Technical Reports Server (NTRS)

    Rivera, Rachel

    2007-01-01

    The following packet is a contamination control training intended for personnel handling or coming to contact with Lunar Reconnaissance Or biter (LRO) flight hardware. This training is being implemented to f amiliarize personnel, coming into contact with LRO hardware, what its contamination sensitivities are and what can be done by all to maint ain its cleanliness levels.

  16. Mattress cleanliness: the role of monitoring and maintenance.

    PubMed

    Aziz, Ann-Marie

    A clean and tidy environment provides the right setting for good patient care. It is fundamental in preventing and/or controlling the spread of healthcare-associated infections (HCAI). Cleanliness is an essential component for the comfort and dignity of patients, particularly those for whom a hospital is home for any length of time. Patients spend a lot of their time in bed so it is important for them to be provided with well maintained and clean mattresses. Beds, and especially the mattresses, should be cleaned and inspected regularly so patients know they are being cared for in a clean and safe environment. To prolong the life of the mattress and reduce infection risks, inspections for damage and contamination must take place on a regular basis. Assessment criteria for the audit of a mattress can include a visual inspection, a cover permeability test and a foam support surface test. These assessments will ensure the mattress is compliant with current standards and identify whether or not they require condemning. Mattress care can be improved by adopting unified good practices that can be standardized and audited regularly.

  17. The Magnetospheric Multiscale Magnetometers

    NASA Technical Reports Server (NTRS)

    Russell, C. T.; Anderson, B. J.; Baumjohann, W.; Bromund, K. R.; Dearborn, D.; Fischer, D.; Le, G.; Leinweber, H. K.; Leneman, D.; Magnes, W.; hide

    2014-01-01

    The success of the Magnetospheric Multiscale mission depends on the accurate measurement of the magnetic field on all four spacecraft. To ensure this success, two independently designed and built fluxgate magnetometers were developed, avoiding single-point failures. The magnetometers were dubbed the digital fluxgate (DFG), which uses an ASIC implementation and was supplied by the Space Research Institute of the Austrian Academy of Sciences and the analogue magnetometer (AFG) with a more traditional circuit board design supplied by the University of California, Los Angeles. A stringent magnetic cleanliness program was executed under the supervision of the Johns Hopkins University,s Applied Physics Laboratory. To achieve mission objectives, the calibration determined on the ground will be refined in space to ensure all eight magnetometers are precisely inter-calibrated. Near real-time data plays a key role in the transmission of high-resolution observations stored onboard so rapid processing of the low-resolution data is required. This article describes these instruments, the magnetic cleanliness program, and the instrument pre-launch calibrations, the planned in-flight calibration program, and the information flow that provides the data on the rapid time scale needed for mission success.

  18. Development of standardized inspections in restaurants using visual assessments and microbiological sampling to quantify the risks.

    PubMed Central

    Tebbutt, G. M.

    1991-01-01

    The relationship between visual inspections carried out by environmental health officers and microbiological examination was studied in 89 restaurants. Using 30 variables a standardized inspection procedure was developed and each of the premises was assessed in six main areas-structure and design, cleaning and cleanliness, personal hygiene, risk of contamination, temperature control, and training and knowledge about food hygiene. Selected foods and specimens from hands, surfaces, and wiping cloths were examined. There were significant associations between all six areas of the inspections. The structure and design were significantly related to the combined score from all the other areas (P less than 0.001). There were no highly significant associations between microbiological examination and visual assessments. The microbial contamination of wiping cloths, however, was related to the cleaning and cleanliness (P = 0.005). Microbial sampling provided additional information to inspections and was a valuable aid. Further development of this risk-assessment approach could provide an effective system for monitoring potential health risks in high-risk food premises. PMID:1936161

  19. Review of Techniques to Achieve Optical Surface Cleanliness and Their Potential Application to Surgical Endoscopes

    PubMed Central

    Kreeft, Davey; Arkenbout, Ewout Aart; Henselmans, Paulus Wilhelmus Johannes; van Furth, Wouter R.; Breedveld, Paul

    2017-01-01

    A clear visualization of the operative field is of critical importance in endoscopic surgery. During surgery the endoscope lens can get fouled by body fluids (eg, blood), ground substance, rinsing fluid, bone dust, or smoke plumes, resulting in visual impairment. As a result, surgeons spend part of the procedure on intermittent cleaning of the endoscope lens. Current cleaning methods that rely on manual wiping or a lens irrigation system are still far from ideal, leading to longer procedure times, dirtying of the surgical site, and reduced visual acuity, potentially reducing patient safety. With the goal of finding a solution to these issues, a literature review was conducted to identify and categorize existing techniques capable of achieving optically clean surfaces, and to show which techniques can potentially be implemented in surgical practice. The review found that the most promising method for achieving surface cleanliness consists of a hybrid solution, namely, that of a hydrophilic or hydrophobic coating on the endoscope lens and the use of the existing lens irrigation system. PMID:28511635

  20. Aqueous Cleaning and Validation for Space Shuttle Propulsion Hardware at the White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Hornung, Steven D.; Biesinger, Paul; Kirsch, Mike; Beeson, Harold; Leuders, Kathy

    1999-01-01

    The NASA White Sands Test Facility (WSTF) has developed an entirely aqueous final cleaning and verification process to replace the current chlorofluorocarbon (CFC) 113 based process. This process has been accepted for final cleaning and cleanliness verification of WSTF ground support equipment. The aqueous process relies on ultrapure water at 50 C (323 K) and ultrasonic agitation for removal of organic compounds and particulate. The cleanliness is verified bv determining the total organic carbon (TOC) content and filtration with particulate counting. The effectiveness of the aqueous methods for detecting hydrocarbon contamination and particulate was compared to the accepted CFC 113 sampling procedures. Testing with known contaminants, such as hydraulic fluid and cutting and lubricating oils, to establish a correlation between aqueous TOC and CFC 113 nonvolatile residue (NVR) was performed. Particulate sampling on cleaned batches of hardware that were randomly separated and sampled by the two methods was performed. This paper presents the approach and results, and discusses the issues in establishing the equivalence of aqueous sampling to CFC 113 sampling, while describing the approach for implementing aqueous techniques on Space Shuttle Propulsion hardware.

  1. Effect of aquatine endodontic cleanser on smear layer removal in the root canals of ex vivo human teeth

    PubMed Central

    GARCIA, Faustino; MURRAY, Peter E.; GARCIA-GODOY, Franklin; NAMEROW, Kenneth N.

    2010-01-01

    Objectives The purpose of this study was to measure and compare the root canal cleanliness and smear layer removal effectiveness of Aquatine Endodontic Cleanser (Aquatine EC) when used as an endodontic irrigating solution in comparison with 6% sodium hypochlorite (NaOCl). Material and Methods Forty-five human teeth were randomly allocated to five treatment groups; the pulp chamber was accessed, cleaned, and shaped by using ProTaper and ProFile rotary instrumentation to an ISO size #40. The teeth were then processed for scanning electron microscopy, and the root canal cleanliness and removal of smear layer were examined. Results The most effective removal of smear layer occurred with Aquatine EC and NaOCl, both with a rinse of EDTA. Conclusions Aquatine EC appears to be the first hypochlorous acid approved by the FDA to be a possible alternative to the use of NaOCl as an intracanal irrigant. Further research is needed to identify safer and more effective alternatives to the use of NaOCl irrigation in endodontics. PMID:20835577

  2. Outsourcing cleaning services increases MRSA incidence: Evidence from 126 english acute trusts.

    PubMed

    Toffolutti, Veronica; Reeves, Aaron; McKee, Martin; Stuckler, David

    2017-02-01

    There has been extensive outsourcing of hospital cleaning services in the NHS in England, in part because of the potential to reduce costs. Yet some argue that this leads to lower hygiene standards and more infections, such as MRSA and, perhaps because of this, the Scottish, Welsh, and Northern Irish health services have rejected outsourcing. This study evaluates whether contracting out cleaning services in English acute hospital Trusts (legal authorities that run one or more hospitals) is associated with risks of hospital-borne MRSA infection and lower economic costs. By linking data on MRSA incidence per 100,000 hospital bed-days with surveys of cleanliness among patient and staff in 126 English acute hospital Trusts during 2010-2014, we find that outsourcing cleaning services was associated with greater incidence of MRSA, fewer cleaning staff per hospital bed, worse patient perceptions of cleanliness and staff perceptions of availability of handwashing facilities. However, outsourcing was also associated with lower economic costs (without accounting for additional costs associated with treatment of hospital acquired infections). Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Effectiveness of short-term, enhanced, infection control support in improving compliance with infection control guidelines and practice in nursing homes: a cluster randomized trial.

    PubMed

    Gopal Rao, G; Jeanes, A; Russell, H; Wilson, D; Atere-Roberts, E; O'Sullivan, D; Donaldson, N

    2009-10-01

    In this prospective cluster randomized controlled trial we evaluated the impact of short-term provision of enhanced infection control support on infection control practice in nursing homes in South London. Twelve nursing homes were recruited, six each in intervention (300 residents) and control (265 residents) groups. Baseline observations of hand hygiene facilities, environmental cleanliness and safe disposal of clinical waste showed poor compliance in both groups. Post-intervention observations showed improvement in both groups. There was no statistical difference between the two groups in the compliance for hand hygiene facilities (P=0.69); environmental cleanliness (P=0.43) and safe disposal of clinical waste (P=0.96). In both groups, greatest improvement was in compliance with safe disposal of clinical waste and the least improvement was in hand hygiene facilities. Since infection control practice improved in intervention and control groups, we could not demonstrate that provision of short-term, enhanced, infection control support in nursing homes had a significant impact in infection control practice.

  4. User Perceptions of Shared Sanitation among Rural Households in Indonesia and Bangladesh

    PubMed Central

    Nelson, Kali B.; Karver, Jonathan; Kullman, Craig; Graham, Jay P.

    2014-01-01

    Background The practice of sharing sanitation facilities does not meet the current World Health Organization/UNICEF definition for what is considered improved sanitation. Recommendations have been made to categorize shared sanitation as improved sanitation if security, user access, and other conditions can be assured, yet limited data exist on user preferences with respect to shared facilities. Objective This study analyzed user perceptions of shared sanitation facilities in rural households in East Java, Indonesia, and Bangladesh. Methods Cross-sectional studies of 2,087 households in East Java and 3,000 households in Bangladesh were conducted using questionnaires and observational methods. Relative risks were calculated to analyze associations between sanitation access and user perceptions of satisfaction, cleanliness, and safety. Results In East Java, 82.4% of households with private improved sanitation facilities reported feeling satisfied with their place of defecation compared to 68.3% of households with shared improved facilities [RR 1.19, 95% CI 1.09, 1.31]. In Bangladesh, 87.7% of households with private improved facilities reported feeling satisfied compared to 74.5% of households with shared improved facilities [RR 1.15, 95% CI 1.10, 1.20]. In East Java, 79.5% of households who reported a clean latrine also reported feeling satisfied with their place of defecation; only 38.9% of households who reported a dirty latrine also reported feeling satisfied [RR 1.74, 95% CI 1.45, 2.08]. Conclusion Simple distinctions between improved and unimproved sanitation facilities tend to misrepresent the variability observed among households sharing sanitation facilities. Our results suggest that private improved sanitation is consistently preferred over any other sanitation option. An increased number of users appeared to negatively affect toilet cleanliness, and lower levels of cleanliness were associated with lower levels of satisfaction. However, when sanitation facilities were clean and shared by a limited number of households, users of shared facilities often reported feeling both satisfied and safe. PMID:25090096

  5. User perceptions of shared sanitation among rural households in Indonesia and Bangladesh.

    PubMed

    Nelson, Kali B; Karver, Jonathan; Kullman, Craig; Graham, Jay P

    2014-01-01

    The practice of sharing sanitation facilities does not meet the current World Health Organization/UNICEF definition for what is considered improved sanitation. Recommendations have been made to categorize shared sanitation as improved sanitation if security, user access, and other conditions can be assured, yet limited data exist on user preferences with respect to shared facilities. This study analyzed user perceptions of shared sanitation facilities in rural households in East Java, Indonesia, and Bangladesh. Cross-sectional studies of 2,087 households in East Java and 3,000 households in Bangladesh were conducted using questionnaires and observational methods. Relative risks were calculated to analyze associations between sanitation access and user perceptions of satisfaction, cleanliness, and safety. In East Java, 82.4% of households with private improved sanitation facilities reported feeling satisfied with their place of defecation compared to 68.3% of households with shared improved facilities [RR 1.19, 95% CI 1.09, 1.31]. In Bangladesh, 87.7% of households with private improved facilities reported feeling satisfied compared to 74.5% of households with shared improved facilities [RR 1.15, 95% CI 1.10, 1.20]. In East Java, 79.5% of households who reported a clean latrine also reported feeling satisfied with their place of defecation; only 38.9% of households who reported a dirty latrine also reported feeling satisfied [RR 1.74, 95% CI 1.45, 2.08]. Simple distinctions between improved and unimproved sanitation facilities tend to misrepresent the variability observed among households sharing sanitation facilities. Our results suggest that private improved sanitation is consistently preferred over any other sanitation option. An increased number of users appeared to negatively affect toilet cleanliness, and lower levels of cleanliness were associated with lower levels of satisfaction. However, when sanitation facilities were clean and shared by a limited number of households, users of shared facilities often reported feeling both satisfied and safe.

  6. The use of filter media to determine filter cleanliness

    NASA Astrophysics Data System (ADS)

    Van Staden, S. J.; Haarhoff, J.

    It is general believed that a sand filter starts its life with new, perfectly clean media, which becomes gradually clogged with each filtration cycle, eventually getting to a point where either head loss or filtrate quality starts to deteriorate. At this point the backwash cycle is initiated and, through the combined action of air and water, returns the media to its original perfectly clean state. Reality, however, dictates otherwise. Many treatment plants visited a decade or more after commissioning are found to have unacceptably dirty filter sand and backwash systems incapable of returning the filter media to a desired state of cleanliness. In some cases, these problems are common ones encountered in filtration plants but many reasons for media deterioration remain elusive, falling outside of these common problems. The South African conditions of highly eutrophic surface waters at high temperatures, however, exacerbate the problems with dirty filter media. Such conditions often lead to the formation of biofilm in the filter media, which is shown to inhibit the effective backwashing of sand and carbon filters. A systematic investigation into filter media cleanliness was therefore started in 2002, ending in 2005, at the University of Johannesburg (the then Rand Afrikaans University). This involved media from eight South African Water Treatment Plants, varying between sand and sand-anthracite combinations and raw water types from eutrophic through turbid to low-turbidity waters. Five states of cleanliness and four fractions of specific deposit were identified relating to in situ washing, column washing, cylinder inversion and acid-immersion techniques. These were measured and the results compared to acceptable limits for specific deposit, as determined in previous studies, though expressed in kg/m 3. These values were used to determine the state of the filters. In order to gain greater insight into the composition of the specific deposits stripped from the media, a four-point characterisation step was introduced for the resultant suspensions based on acid-solubility and volatility. Results showed that a reasonably effective backwash removed a median specific deposit of 0.89 kg/m 3. Further washing in a laboratory column removed a median specific deposit of 1.34 kg/m 3. Media subjected to a standardised cylinder inversion procedure removed a median specific deposit of 2.41 kg/m 3. Immersion in a strong acid removed a median specific deposit of 35.2 kg/m 3. The four-point characterisation step showed that the soluble-volatile fraction was consistently small in relation to the other fractions. The organic fraction was quite high at the RG treatment plant and the soluble-non-volatile fraction was particularly high at the BK treatment plant.

  7. Safety Assurances at Space Test Centres: Lessons Learned

    NASA Astrophysics Data System (ADS)

    Alarcon Ruiz, Raul; O'Neil, Sean; Valls, Rafel Prades

    2010-09-01

    The European Space Agency’s(ESA) experts in quality, cleanliness and contamination control, safety, test facilities and test methods have accumulated valuable experience during the performance of dedicated audits of space test centres in Europe over a period of 10 years. This paper is limited to a summary of the safety findings and provides a valuable reference to the lessons learned, identifying opportunities for improvement in the areas of risk prevention measures associated to the safety of all test centre personnel, the test specimen, the test facilities and associated infrastructure. Through the analysis of the audit results the authors present what are the main lessons learned, and conclude how an effective safety management system will contribute to successful test campaigns and have a positive impact on the cost and schedule of space projects.

  8. Long-term quality assurance of [(18)F]-fluorodeoxyglucose (FDG) manufacturing.

    PubMed

    Gaspar, Ludovit; Reich, Michal; Kassai, Zoltan; Macasek, Fedor; Rodrigo, Luis; Kruzliak, Peter; Kovac, Peter

    2016-01-01

    Nine years of experience with 2286 commercial synthesis allowed us to deliver comprehensive information on the quality of (18)F-FDG production. Semi-automated FDG production line using Cyclone 18/9 machine (IBA Belgium), TRACERLab MXFDG synthesiser (GE Health, USA) using alkalic hydrolysis, grade "A" isolator with dispensing robotic unit (Tema Sinergie, Italy), and automatic control system under GAMP5 (minus2, Slovakia) was assessed by TQM tools as highly reliable aseptic production line, fully compliant with Good Manufacturing Practice and just-in-time delivery of FDG radiopharmaceutical. Fluoride-18 is received in steady yield and of very high radioactive purity. Synthesis yields exhibited high variance connected probably with quality of disposable cassettes and chemicals sets. Most performance non-conformities within the manufacturing cycle occur at mechanical nodes of dispensing unit. The long-term monitoring of 2286 commercial synthesis indicated high reliability of automatic synthesizers. Shewhart chart and ANOVA analysis showed that minor non-compliances occurred were mostly caused by the declinations of less experienced staff from standard operation procedures, and also by quality of automatic cassettes. Only 15 syntheses were found unfinished and in 4 cases the product was out-of-specification of European Pharmacopoeia. Most vulnerable step of manufacturing was dispensing and filling in grade "A" isolator. Its cleanliness and sterility was fully controlled under the investigated period by applying hydrogen peroxide vapours (VHP). Our experience with quality assurance in the production of [(18)F]-fluorodeoxyglucose (FDG) at production facility of BIONT based on TRACERlab MXFDG production module can be used for bench-marking of the emerging manufacturing and automated manufacturing systems.

  9. Long-term quality assurance of [18F]-fluorodeoxyglucose (FDG) manufacturing

    PubMed Central

    Gaspar, Ludovit; Reich, Michal; Kassai, Zoltan; Macasek, Fedor; Rodrigo, Luis; Kruzliak, Peter; Kovac, Peter

    2016-01-01

    Nine years of experience with 2286 commercial synthesis allowed us to deliver comprehensive information on the quality of 18F-FDG production. Semi-automated FDG production line using Cyclone 18/9 machine (IBA Belgium), TRACERLab MXFDG synthesiser (GE Health, USA) using alkalic hydrolysis, grade “A” isolator with dispensing robotic unit (Tema Sinergie, Italy), and automatic control system under GAMP5 (minus2, Slovakia) was assessed by TQM tools as highly reliable aseptic production line, fully compliant with Good Manufacturing Practice and just-in-time delivery of FDG radiopharmaceutical. Fluoride-18 is received in steady yield and of very high radioactive purity. Synthesis yields exhibited high variance connected probably with quality of disposable cassettes and chemicals sets. Most performance non-conformities within the manufacturing cycle occur at mechanical nodes of dispensing unit. The long-term monitoring of 2286 commercial synthesis indicated high reliability of automatic synthesizers. Shewhart chart and ANOVA analysis showed that minor non-compliances occurred were mostly caused by the declinations of less experienced staff from standard operation procedures, and also by quality of automatic cassettes. Only 15 syntheses were found unfinished and in 4 cases the product was out-of-specification of European Pharmacopoeia. Most vulnerable step of manufacturing was dispensing and filling in grade “A” isolator. Its cleanliness and sterility was fully controlled under the investigated period by applying hydrogen peroxide vapours (VHP). Our experience with quality assurance in the production of [18F]-fluorodeoxyglucose (FDG) at production facility of BIONT based on TRACERlab MXFDG production module can be used for bench-marking of the emerging manufacturing and automated manufacturing systems. PMID:27508102

  10. Project Help. An Elementary Curriculum Guide Designed to Help Students Help Themselves.

    ERIC Educational Resources Information Center

    Cranston School Dept., RI.

    This two-part curriculum is designed to teach elementary students basic life skills that will enable them to assume greater responsibility for themselves. Part 1, the primary curriculum, is designed for grades 3 and 4. Five units of instruction are included in the primary curriculum: home management, foods, personal cleanliness, sewing, and…

  11. Norms Relating to Environmental Care in Public Places: A Study of Kibbutzim.

    ERIC Educational Resources Information Center

    Jacobsen, Chanoch; Avi-Itzhak, Tamar

    The care or neglect which people bestow on the appearance and cleanliness of the public places in which they live and work is the central focus of this paper. Basically the phenomenon that is studied is that encountered when people who are usually law abiding, orderly, and responsible citizens deviate from the prescribed and insituttionalized…

  12. In-flight friction and wear mechanism

    NASA Technical Reports Server (NTRS)

    Devine, E. J.; Evans, H. E.

    1975-01-01

    A unique mechanism developed for conducting friction and wear experiments in orbit is described. The device is capable of testing twelve material samples simultaneously. Parameters considered critical include: power, weight, volume, mounting, cleanliness, and thermal designs. The device performed flawlessly in orbit over an eighteen month period and demonstrated the usefulness of this design for future unmanned spacecraft or shuttle applications.

  13. "Not Rocket Science" or "No Silver Bullet"? Media and Government Discourses about MRSA and Cleanliness

    ERIC Educational Resources Information Center

    Koteyko, Nelya; Nerlich, Brigitte; Crawford, Paul; Wright, Nick

    2008-01-01

    Methicillin-resistant "Staphylococcus aureus" (MRSA), commonly called a superbug, has recently been a major political issue in the UK, playing a significant role in debates over health policy in the general election held in 2005. While science recognizes the lack of evidence with regards to the effectiveness of existing measures…

  14. Probation and Head Lice: The Intersection of Corrections and Education

    ERIC Educational Resources Information Center

    Kronick, Robert F.

    2006-01-01

    The critical incident that drove this article involved a single mother who was on probation for drug offenses. Her two daughters were sent home from their Title I urban elementary school on a frequent basis because of head lice. This situation prompted several questions: Can we and should we be able to legislate and enforce cleanliness? Is…

  15. Oil Spill Cleanup

    ERIC Educational Resources Information Center

    Kauble, Christena Ann

    2011-01-01

    Several classroom activities using a model of a seashore and an oil spill demonstrate the basic properties of oil spills in oceans. Students brainstorm about how to best clean up the mess. They work in teams, and after agreeing on how they will proceed, their method is tested by measuring the amount of oil removed and by rating the cleanliness of…

  16. Clean People in a Clean World

    ERIC Educational Resources Information Center

    Cottey, Alan

    2012-01-01

    Bathing is here treated as an exemplar of the widespread profligacy of prosperous people and of the continually expanding expectations for all on this overloaded planet. The author places cleanliness in a wider context, not merely of animals but of all living organisms. With this in mind, it is possible to consider, in a wider than usual manner,…

  17. Working Conditions in Carpet Weaving Workshops and Muscu-loskeletal Complaints among Workers in Tabriz - Iran

    PubMed Central

    Nazari, Jalil; Mahmoudi, Nader; Dianat, Iman; Graveling, Richard

    2012-01-01

    Background: Carpet weaving operations usualy involve poor working conditions that can lead to the development of musculoskeletal disorders (MSDs). This study investigated MSDs among car¬pet weavers in relation to working conditions from workers' view in Tabriz City, Northwest Iran. Methods: This cross-sectional and descriptive study was conducted in city of Tabriz, Iran. Data were col¬lected using interviews and questionnaires. The study population consisted of 200 randomly selected healthy weavers from twenty five active carpet weaving workshops. Results: The results showed a high prevalence of musculoskeletal problems among the study population. The most commonly affected body areas were neck, lower back, ankles/feet, hands/wrists, upper back, shoulders and knees, respectively. More than half of the weavers were not satisfied with the thermal con¬dition, noise level and cleanliness of the air in the workshops. The result indicated a significant relation¬ship between upper back symptoms and daily working time and between lower back symptoms and the numbers of rows of knots woven in a day. Weavers' satisfaction with hand tools shape and thermal condi¬tion of the workshops were associated with lower back symptoms, whereas satisfaction with weaving looms were associated with upper back complaints. Conclusion: The poor working condition of hand-woven carpet workshops such as environmental con¬ditions and work station design and tools should be the subject of ergonomics interventions. PMID:24688943

  18. Listening to the customer: implementing a patient satisfaction measurement system.

    PubMed

    Cohen, L; Delaney, P; Boston, P

    1994-01-01

    Patient satisfaction is an important issue in positioning ambulatory medical services. An effective patient satisfaction measurement program not only helps hospital managers improve the quality of clinical and administrative activities, but also helps the hospital remain viable in increasingly competitive markets. A method for the design and measurement of patient satisfaction with outpatient Endoscopy Lab services is described in this article. The survey focuses on the sequence of events experienced by the patient. Outcome measures of primary interest include global patient satisfaction and the likelihood of using the service again if given a choice. Analysis of patient responses shows that global satisfaction with the outpatient experience is positively associated with service return intention. Additional analysis shows that facility cleanliness, privacy and nurse attention are most strongly associated with global patient satisfaction. Results underscore the importance of various service attributes on patient satisfaction and return intention and of the need to further expand the uses of patient satisfaction measurement in the outpatient Endoscopy Lab.

  19. Assessment of statistical uncertainty in the quantitative analysis of solid samples in motion using laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Cabalín, L. M.; González, A.; Ruiz, J.; Laserna, J. J.

    2010-08-01

    Statistical uncertainty in the quantitative analysis of solid samples in motion by laser-induced breakdown spectroscopy (LIBS) has been assessed. For this purpose, a LIBS demonstrator was designed and constructed in our laboratory. The LIBS system consisted of a laboratory-scale conveyor belt, a compact optical module and a Nd:YAG laser operating at 532 nm. The speed of the conveyor belt was variable and could be adjusted up to a maximum speed of 2 m s - 1 . Statistical uncertainty in the analytical measurements was estimated in terms of precision (reproducibility and repeatability) and accuracy. The results obtained by LIBS on shredded scrap samples under real conditions have demonstrated that the analytical precision and accuracy of LIBS is dependent on the sample geometry, position on the conveyor belt and surface cleanliness. Flat, relatively clean scrap samples exhibited acceptable reproducibility and repeatability; by contrast, samples with an irregular shape or a dirty surface exhibited a poor relative standard deviation.

  20. Root Cause Failure Analysis of Stator Winding Insulation failure on 6.2 MW hydropower generator

    NASA Astrophysics Data System (ADS)

    Adhi Nugroho, Agus; Widihastuti, Ida; Ary, As

    2017-04-01

    Insulation failure on generator winding insulation occurred in the Wonogiri Hydropower plant has caused stator damage since ase was short circuited to ground. The fault has made the generator stop to operate. Wonogiri Hydropower plant is one of the hydroelectric plants run by PT. Indonesia Power UBP Mrica with capacity 2 × 6.2 MW. To prevent damage to occur again on hydropower generators, an analysis is carried out using Root Cause Failure Analysis RCFA is a systematic approach to identify the root cause of the main orbasic root cause of a problem or a condition that is not wanted. There are several aspects to concerned such as: loading pattern and operations, protection systems, generator insulation resistance, vibration, the cleanliness of the air and the ambient air. Insulation damage caused by gradual inhomogeneous cooling at the surface of winding may lead in to partial discharge. In homogeneous cooling may present due to lattice hampered by dust and oil deposits. To avoid repetitive defects and unwanted condition above, it is necessary to perform major maintenance overhaul every 5000-6000 hours of operation.

  1. Determination of lead isotopes in a new Greenland deep ice core at the sub-picogram per gram level by thermal ionization mass spectrometry using an improved decontamination method.

    PubMed

    Han, Changhee; Burn-Nunes, Laurie J; Lee, Khanghyun; Chang, Chaewon; Kang, Jung-Ho; Han, Yeongcheol; Hur, Soon Do; Hong, Sungmin

    2015-08-01

    An improved decontamination method and ultraclean analytical procedures have been developed to minimize Pb contamination of processed glacial ice cores and to achieve reliable determination of Pb isotopes in North Greenland Eemian Ice Drilling (NEEM) deep ice core sections with concentrations at the sub-picogram per gram level. A PL-7 (Fuso Chemical) silica-gel activator has replaced the previously used colloidal silica activator produced by Merck and has been shown to provide sufficiently enhanced ion beam intensity for Pb isotope analysis for a few tens of picograms of Pb. Considering the quantities of Pb contained in the NEEM Greenland ice core and a sample weight of 10 g used for the analysis, the blank contribution from the sample treatment was observed to be negligible. The decontamination and analysis of the artificial ice cores and selected NEEM Greenland ice core sections confirmed the cleanliness and effectiveness of the overall analytical process. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Static Time-of-Flight Secondary Ion Mass Spectrometry (SIMS) | Materials

    Science.gov Websites

    -Flight Secondary Ion Mass Spectrometry (SIMS) Image of high mass resolution and mass accuracy provided by TOF SIMS We used the high mass resolution and mass accuracy of TOF SIMS to study surface cleanliness acidic wash resulted in contamination by Fe and other metals. Without high mass accuracy, the CaO signal

  3. Cleaning and Cleanliness Measurement of Additive Manufactured Parts

    NASA Technical Reports Server (NTRS)

    Mitchell, Mark A.; Edwards, Kevin; Fox, Eric; Boothe, Richard

    2017-01-01

    Additive Manufacturing processes allow for the manufacture of complex three dimensional components that otherwise could not be manufactured. Post treatment processes require the removal of any remnant bulk powder that may become entrapped within small cavities and channels within a component. This project focuses on several gross cleaning methods and the verification metrics associated with additive manufactured parts for oxygen propulsion usage.

  4. Description of European Space Agency (ESA) Double Walled Isolator (DWI) Breadboard Currently Under Development for Demonstration of Critical Technology Foreseen to be Used in the Mars Sample Receiving Facility (MSRF)

    NASA Astrophysics Data System (ADS)

    Vrublevskis, J.; Berthoud, L.; McCulloch, Y.; Bowman, P.; Holt, J.; Bridges, J.; Bennett, A.; Gaubert, F.; Duvet, L.

    2018-04-01

    The need for biocontainment from Planetary Protection Policy and the need for cleanliness for scientific investigation requires that the samples returned from Mars by the Mars Sample Return (MSR) mission must be handled in a Double Walled Isolator (DWI).

  5. Cleanliness in context: reconciling hygiene with a modern microbial perspective.

    PubMed

    Vandegrift, Roo; Bateman, Ashley C; Siemens, Kyla N; Nguyen, May; Wilson, Hannah E; Green, Jessica L; Van Den Wymelenberg, Kevin G; Hickey, Roxana J

    2017-07-14

    The concept of hygiene is rooted in the relationship between cleanliness and the maintenance of good health. Since the widespread acceptance of the germ theory of disease, hygiene has become increasingly conflated with sterilization. In reviewing studies across the hygiene literature (most often hand hygiene), we found that nearly all studies of hand hygiene utilize bulk reduction in bacterial load as a proxy for reduced transmission of pathogenic organisms. This treatment of hygiene may be insufficient in light of recent microbial ecology research, which has demonstrated that humans have intimate and evolutionarily significant relationships with a diverse assemblage of microorganisms (our microbiota). The human skin is home to a diverse and specific community of microorganisms, which include members that exist across the ecological spectrum from pathogen through commensal to mutualist. Most evidence suggests that the skin microbiota is likely of direct benefit to the host and only rarely exhibits pathogenicity. This complex ecological context suggests that the conception of hygiene as a unilateral reduction or removal of microbes has outlived its usefulness. As such, we suggest the explicit definition of hygiene as "those actions and practices that reduce the spread or transmission of pathogenic microorganisms, and thus reduce the incidence of disease."

  6. Supersonic gas-liquid cleaning system

    NASA Technical Reports Server (NTRS)

    Caimi, Raoul E. B.; Thaxton, Eric A.

    1994-01-01

    A system to perform cleaning and cleanliness verification is being developed to replace solvent flush methods using CFC 113 for fluid system components. The system is designed for two purposes: internal and external cleaning and verification. External cleaning is performed with the nozzle mounted at the end of a wand similar to a conventional pressure washer. Internal cleaning is performed with a variety of fixtures designed for specific applications. Internal cleaning includes tubes, pipes, flex hoses, and active fluid components such as valves and regulators. The system uses gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the object to be cleaned. Compressed air or any inert gas may be used to provide the conveying medium for the liquid. The converging-diverging nozzles accelerate the gas-liquid mixture to supersonic velocities. The liquid being accelerated may be any solvent including water. This system may be used commercially to replace CFC and other solvent cleaning methods widely used to remove dust, dirt, flux, and lubricants. In addition, cleanliness verification can be performed without the solvents which are typically involved. This paper will present the technical details of the system, the results achieved during testing at KSC, and future applications for this system.

  7. An Empirical Study on the Preference of Supermarkets with Analytic Hierarchy Process Model

    NASA Astrophysics Data System (ADS)

    Weng Siew, Lam; Singh, Ranjeet; Singh, Bishan; Weng Hoe, Lam; Kah Fai, Liew

    2018-04-01

    Large-scale retailers are very important to the consumers in this fast-paced world. Selection of desirable market to purchase products and services becomes major concern among consumers in their daily life due to vast choices available. Therefore, the objective of this paper is to determine the most preferred supermarket among AEON, Jaya Grocer, Tesco, Giant and Econsave by the undergraduate students in Malaysia with Analytic Hierarchy Process (AHP) model. Besides that, this study also aims to determine the priority of decision criteria in the selection of supermarkets among the undergraduatestudents with AHP model. The decision criteria employed in this study are product quality, competitive price, cleanliness, product variety, location, good price labelling, fast checkout and employee courtesy. The results of this study show that AEON is the most preferred supermarket followed by Jaya Grocer, Tesco, Econsave and Giant among the students based on AHP model. Product quality, cleanliness and competitive price are ranked as the top three influential factors in this study. This study is significant because it helps to determine the most preferred supermarket as well as the most influential decision criteria in the preference of supermarkets among the undergraduate students with AHP model.

  8. Oral cleanliness and gingival health among Special Olympics athletes in Europe and Eurasia.

    PubMed

    Marks, Luc; Fernandez, Carla; Kaschke, Imke; Perlman, Steven

    2015-09-01

    Special Olympics athletes, as well as the general population of people with intellectual disabilities, are expected to have poorer gingival health. The aim of the study is to explore the prevalence of gingival signs of inflammation and its relationship to oral cleanliness and age among Special Olympics athletes from Europe and Eurasia. A retrospective longitudinal study was performed with data collected through standardized oral from 15.941 athletes from annual Special Olympics events held in 49 countries, from Europe and Eurasia between 2007 and 2012. The data was analysed descriptively, with One-Way ANOVA test and Chi-Square test. The level of significance was predetermined at a p value < 0.05. A total of 7,754 athletes presented with gingival signs (48.64%). There were no significant differences (p= 0,095) in mean gingival signs between age groups, however the association between mouth cleaning and age, was statistically significant. The data suggests that there is a high prevalence of gingival signs among individuals with special needs; over 50% in more than 20 countries. Therefore, there is a serious need for education and preventive programs for the patients, their parents and caregivers.

  9. Preventing trachoma through environmental sanitation: a review of the evidence base.

    PubMed Central

    Prüss, A.; Mariotti, S. P.

    2000-01-01

    A review of the available evidence for the associations between environmental sanitation and transmission of trachoma was undertaken with a view to identifying preventive interventions. The WHO Global Alliance for the Elimination of Trachoma by the Year 2020 (GET2020) has adopted the "SAFE" strategy, consisting of four components: Surgery, Antibiotic treatment, promotion of Facial cleanliness and initiation of Environmental changes. This review of 19 studies selected from the 39 conducted in different parts of the world shows that there is clear evidence to support the recommendation of facial cleanliness and environmental improvements (i.e. the F and E components of the SAFE strategy) to prevent trachoma. Person-to-person contact and flies appear to constitute the major transmission pathways. Improvement of personal and community hygiene has great potential for a sustainable reduction in trachoma transmission. Controlled clinical trials are needed to estimate the relative contribution of various elements to the risk of transmission of trachoma and the effectiveness of different interventions. These could show the relative attributable risks and effectiveness of interventions to achieve improvement of personal hygiene and fly control by environmental improvements, alone or in combination, and with or without antibiotic treatment. PMID:10743299

  10. Ultra Pure Water Cleaning Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

    NASA Technical Reports Server (NTRS)

    Calaway, Michael J.; Burkett, P. J.; Allton, J. H.; Allen, C. C.

    2013-01-01

    Future sample return missions will require strict protocols and procedures for reducing inorganic and organic contamination in isolation containment systems. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs [1, 2]. As part of this in-depth organic study, the current curatorial technical support procedure (TSP) 23 was used for cleaning the gloveboxes with ultra pure water (UPW) [3-5]. Particle counts and identification were obtained that could be used as a benchmark for future mission designs that require glovebox decontamination. The UPW baseline study demonstrates that TSP 23 works well for gloveboxes that have been thoroughly degreased. However, TSP 23 could be augmented to provide even better glovebox decontamination. JSC 03243 could be used as a starting point for further investigating optimal cleaning techniques and procedures. DuPont Vertrel XF or other chemical substitutes to replace Freon- 113, mechanical scrubbing, and newer technology could be used to enhance glovebox cleanliness in addition to high purity UPW final rinsing. Future sample return missions will significantly benefit from further cleaning studies to reduce inorganic and organic contamination.

  11. Plasma surface cleaning in a microwave plasma source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, C.C.; Nelson, W.D.; Haselton, H.H.

    1994-03-01

    A microwave electron cyclotron resonance (ECR) plasma source has been operated to produce reactive plasmas of oxygen and its mixture with argon. Aluminum samples (0.95 cm by 1.9 cm) were coated with thin films (<20 {mu}m in thickness) of Shell Vitrea oil and cleaned by using such reactive plasmas. The plasma cleaning was done in discharge conditions of microwave power up to 1300 W, radio frequency power up to 200 W, biased potential up to 400 V, gas pressures up to 5 mtorr, and operating time up to 35 min. The surface texture of the postcleaned samples has been examinedmore » visually. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured clean rates of low-pressure (0.5-mtorr) argon/oxygen plasmas were as high as 2.7 {mu}m/min. X-ray photoelectron spectroscopy (XPS) was used to determine cleanliness of the sample surfaces after plasma cleaning. The XPS study on polished samples confirmed the effectiveness of plasma cleaning in achieving atomic level of surface cleanliness. In this technical memorandum plasma properties, cleaning phenomena, and significant results are reported and discussed.« less

  12. Supersonic gas-liquid cleaning system

    NASA Astrophysics Data System (ADS)

    Caimi, Raoul E. B.; Thaxton, Eric A.

    1994-02-01

    A system to perform cleaning and cleanliness verification is being developed to replace solvent flush methods using CFC 113 for fluid system components. The system is designed for two purposes: internal and external cleaning and verification. External cleaning is performed with the nozzle mounted at the end of a wand similar to a conventional pressure washer. Internal cleaning is performed with a variety of fixtures designed for specific applications. Internal cleaning includes tubes, pipes, flex hoses, and active fluid components such as valves and regulators. The system uses gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the object to be cleaned. Compressed air or any inert gas may be used to provide the conveying medium for the liquid. The converging-diverging nozzles accelerate the gas-liquid mixture to supersonic velocities. The liquid being accelerated may be any solvent including water. This system may be used commercially to replace CFC and other solvent cleaning methods widely used to remove dust, dirt, flux, and lubricants. In addition, cleanliness verification can be performed without the solvents which are typically involved. This paper will present the technical details of the system, the results achieved during testing at KSC, and future applications for this system.

  13. Balanced Rotating Spray Tank and Pipe Cleaning and Cleanliness Verification System

    NASA Technical Reports Server (NTRS)

    Caimi, Raoul E. B. (Inventor); Thaxton, Eric A. (Inventor)

    1998-01-01

    A system for cleaning and verifying the cleanliness of the interior surfaces of hollow items, such as small bottles, tanks, pipes and tubes, employs a rotating spray head for supplying a gas-liquid cleaning mixture to the item's surface at a supersonic velocity. The spray head incorporates a plurality of nozzles having diverging cross sections so that the incoming gas-liquid mixture is first converged within the spray head and then diverged through the nozzles, thereby accelerating the mixture to a supersonic velocity. In the preferred embodiment, three nozzles are employed; one forwardly facing nozzle at the end of the spray head and two oppositely facing angled nozzles exiting on opposite sides of the spray head which balance each other, and therefore impart no net side load on the spray head. A drive mechanism is provided to rotate the spray head and at the same time move the head back and forth within the item to be cleaned. The drive mechanism acts on a long metal tube to which the spray head is fixed, and thus no moving parts are exposed to the interior surfaces of the items to be cleaned, thereby reducing the risk of contamination.

  14. Medicalization and morality in a weak state: health, hygiene and water in Dar Es Salaam, Tanzania.

    PubMed

    Obrist, Brigit

    2004-04-01

    Inspired by Foucault, many studies have examined the medicalization of everyday life in Western societies. This paper reconsiders potentials and limitations of this concept in an African city. Grounded in ethnographic research in Dar es Salaam, Tanzania, it concentrates on cleanliness, health and water in a lower middle-class neighbourhood. The findings show that women are familiar with professional health development discourses emphasizing cleanliness as a high value linked to bodily and domestic health. These discourses have been diffused in schools, clinics and other institutions during the colonial and socialist period. Women not only refer to these discourses, they try to reproduce them in daily practice and even demand them. This coercive yet voluntary nature of institutionalized discourses points to 'paradoxes of medicalization' also found in Western societies. It acquires, however, different meanings in a weak state like contemporary Tanzania which hardly manages to institutionalize medicalization through professional practice. Under such conditions, women who choose to follow health development discourses suffer a heavier practical, intellectual and emotional burden than those who are less committed. This may at least partly explain why many women assume a pragmatic stance towards the medicalization of everyday life.

  15. Cleanliness evaluation of rough surfaces with diffuse IR reflectance

    NASA Technical Reports Server (NTRS)

    Pearson, L. H.

    1995-01-01

    Contamination on bonding surfaces has been determined to be a primary cause for degraded bond strength in certain solid rocket motor bondlines. Hydrocarbon and silicone based organic contaminants that are airborne or directly introduced to a surface are a significant source of contamination. Diffuse infrared (IR) reflectance has historically been used as an effective technique for detection of organic contaminants, however, common laboratory methods involving the use of a Fourier transform IR spectrometer (FTIR) are impractical for inspecting the large bonding surface areas found on solid rocket motors. Optical methods involving the use of acousto-optic tunable filters and fixed bandpass optical filters are recommended for increased data acquisition speed. Testing and signal analysis methods are presented which provide for simultaneous measurement of contamination concentration and roughness level on rough metal surfaces contaminated with hydrocarbons.

  16. A rapid method of toilet training the institutionalized retarded1

    PubMed Central

    Azrin, N. H.; Foxx, R. M.

    1971-01-01

    Incontinence is a major unsolved problem in the institutional care of the profoundly retarded. A reinforcement and social analysis of incontinence was used to develop a procedure that would rapidly toilet train retardates and motivate them to remain continent during the day in their ward setting. Nine profoundly retarded adults were given intensive training (median of four days per patient), the distinctive features of which were artificially increasing the frequency of urinations, positive reinforcement of correct toileting but a delay for “accidents”, use of new automatic apparatus for signalling elimination, shaping of independent toileting, cleanliness training, and staff reinforcement procedures. Incontinence was reduced immediately by about 90% and eventually decreased to near-zero. These results indicate the present procedure is an effective, rapid, enduring, and administratively feasible solution to the problem of incontinence of the institutionalized retarded. PMID:16795291

  17. JPL Contamination Control Engineering

    NASA Technical Reports Server (NTRS)

    Blakkolb, Brian

    2013-01-01

    JPL has extensive expertise fielding contamination sensitive missions-in house and with our NASA/industry/academic partners.t Development and implementation of performance-driven cleanliness requirements for a wide range missions and payloads - UV-Vis-IR: GALEX, Dawn, Juno, WFPC-II, AIRS, TES, et al - Propulsion, thermal control, robotic sample acquisition systems. Contamination control engineering across the mission life cycle: - System and payload requirements derivation, analysis, and contamination control implementation plans - Hardware Design, Risk trades, Requirements V-V - Assembly, Integration & Test planning and implementation - Launch site operations and launch vehicle/payload integration - Flight ops center dot Personnel on staff have expertise with space materials development and flight experiments. JPL has capabilities and expertise to successfully address contamination issues presented by space and habitable environments. JPL has extensive experience fielding and managing contamination sensitive missions. Excellent working relationship with the aerospace contamination control engineering community/.

  18. Systematic technology transfer from biology to engineering.

    PubMed

    Vincent, Julian F V; Mann, Darrell L

    2002-02-15

    Solutions to problems move only very slowly between different disciplines. Transfer can be greatly speeded up with suitable abstraction and classification of problems. Russian researchers working on the TRIZ (Teoriya Resheniya Izobretatelskikh Zadatch) method for inventive problem solving have identified systematic means of transferring knowledge between different scientific and engineering disciplines. With over 1500 person years of effort behind it, TRIZ represents the biggest study of human creativity ever conducted, whose aim has been to establish a system into which all known solutions can be placed, classified in terms of function. At present, the functional classification structure covers nearly 3 000 000 of the world's successful patents and large proportions of the known physical, chemical and mathematical knowledge-base. Additional tools are the identification of factors which prevent the attainment of new technology, leading directly to a system of inventive principles which will resolve the impasse, a series of evolutionary trends of development, and to a system of methods for effecting change in a system (Su-fields). As yet, the database contains little biological knowledge despite early recognition by the instigator of TRIZ (Genrich Altshuller) that one day it should. This is illustrated by natural systems evolved for thermal stability and the maintenance of cleanliness.

  19. Electrosurgical Smoke: Ultrafine Particle Measurements and Work Environment Quality in Different Operating Theatres.

    PubMed

    Romano, Francesco; Gustén, Jan; De Antonellis, Stefano; Joppolo, Cesare M

    2017-01-30

    Air cleanliness in operating theatres (OTs) is an important factor for preserving the health of both the patient and the medical staff. Particle contamination in OTs depends mainly on the surgery process, ventilation principle, personnel clothing systems and working routines. In many open surgical operations, electrosurgical tools (ESTs) are used for tissue cauterization. ESTs generate a significant airborne contamination, as surgical smoke. Surgical smoke is a work environment quality problem. Ordinary surgical masks and OT ventilation systems are inadequate to control this problem. This research work is based on numerous monitoring campaigns of ultrafine particle concentrations in OTs, equipped with upward displacement ventilation or with a downward unidirectional airflow system. Measurements performed during ten real surgeries highlight that the use of ESTs generates a quite sharp and relevant increase of particle concentration in the surgical area as well within the entire OT area. The measured contamination level in the OTs are linked to surgical operation, ventilation principle, and ESTs used. A better knowledge of airborne contamination is crucial for limiting the personnel's exposure to surgical smoke. Research results highlight that downward unidirectional OTs can give better conditions for adequate ventilation and contaminant removal performances than OTs equipped with upward displacement ventilation systems.

  20. Mass Spectrometer for Airborne Micro-Organisms

    NASA Technical Reports Server (NTRS)

    Sinha, M. P.; Friedlander, S. K.

    1986-01-01

    Bacteria and other micro-organisms identified continously with aid of new technique for producing samples for mass spectrometer. Technique generates aerosol of organisms and feeds to spectrometer. Given species of organism produces characteristic set of peaks in mass spectrum and thereby identified. Technique useful for monitoring bacterial makeup in environmental studies and in places where cleanliness is essential, such as hospital operating rooms, breweries, and pharmaceutical plants.

  1. Cluster: A fleet of four spacecraft to study plasma structures in three dimensions

    NASA Technical Reports Server (NTRS)

    Schmidt, R.; Goldstein, M. L.

    1988-01-01

    The four Cluster spacecraft are spin stabilized spacecraft which are designed and built under stringent requirements as far as electromagnetic cleanliness is concerned. Conductive surfaces and low electromagnetic background noise are mandatory for accurate electric field and cold plasma measurements. The mission is implemented in collaboration between ESA and NASA. A Russian mission will be closely coordinated with Cluster.

  2. Alternative Fuels Compatibility with Army Equipment Testing-Effects of JP-8+100 on Military Filtration Equipment

    DTIC Science & Technology

    2012-02-21

    Summary of Proposed Additive Packages for API /IP 1581 4th Edition ...................................... 4 Table 2. Summary of DoD Test Results...15 Table 8. ISO 4406 Cleanliness Codes for the API /IP 1581 5th Edition...Improver WSIM Water Separation Index Measure NSN National Stock Number API American Petroleum Institute DESC Defense Energy Support Center DOE Design of

  3. Chemists Clean Up: A History and Exploration of the Craft of Soapmaking--How Soap Came To Be Common in America.

    ERIC Educational Resources Information Center

    Kostka, Kimberly L.; McKay, David D.

    2002-01-01

    Explores the confluence of cultural and technological changes that led to the transformation of soap into a ubiquitous and well-used object. Picks up the timeline for the development of soap in the early American republic when soapmaking was a householder's task. Traces the rise of the American cleanliness movement and correlates the rise to…

  4. Korean Affairs Report

    DTIC Science & Technology

    1986-02-18

    cooperation among themselves and to give top priority to preparing for the Asian Games . The president directed the sports minister to complete construction at...should conduct a nationwide campaign to promote public order, kindness and cleanliness. Chon also asked the sports minister to boost the competitive ...Jan 86) 4 Daily Views Soviet Foreign Minister’s Visit to North (Editorial; THE KOREA HERALD, 25 Jan 86) 5 OLYMPIC GAMES State Advisors

  5. Study on the Control of Cleanliness for X90 Pipeline in the Secondary Refining Process

    NASA Astrophysics Data System (ADS)

    Chu, Ren Sheng; Liu, Jin Gang; Li, Zhan Jun

    X90 pipeline steel requires ultra low for sulfur content and gas content in the smelting process. The secondary refining process is very important for X90 pipeline in smelting process and the control of cleanliness is the key for the secondary refining process in the steelmaking process for Pretreatment of hot metal → LD → LF refining → RH refining → Calcium treatment → CC. In the current paper, the cleanliness control method of secondary refining was analyzed for the evolution of non-metallic inclusions in the secondary refining prcess and related changes for composition in steel. The size, composition and the type of the non-metallic inclusions were analyzed by aspex explorer automated scanning electron microscope in X90 pipeline samples for 20mm * 25mm * 25mm by the line cutting. The results show that the number of non-metallic inclusions in steel decrease from the beginning of the LF refining to the RH refining. In the composition of the Non-metallic inclusions, the initial non-metallic inclusions of alumina is converted to two comple-type non-metallic inclusions. Most of them, the non-metallic inclusions were composed by the calcium aluminate and CaS. The others are that the spinel is the core, peripheral parcels calcium aluminate nonmetallic inclusions for complex-type non-metallic inclusions. For the size of the non-metallic inclusions, the non-metallic inclusions for size larger than 100µm is converted to 5 20µm based small size non-metallic inclusions. While the S content of the steel decreased from 0.012% to 0.0012% or less, Al content is kept at between 0.025% to 0.035% and the quality for the casting slab satisfies the requirement of the steel. The ratings for various types of the non-metallic inclusions are 1.5 or less. The control strategy for the inclusions in 90 pipeline is small size, diffuse distribution and little amount of the deformation after rolling. On the contrary, the specific chemical composition of the inclusions is not important, single component in the inclusions is better.

  6. Curation of Samples from Mars

    NASA Astrophysics Data System (ADS)

    Lindstrom, D.; Allen, C.

    One of the strong scientific reasons for returning samples from Mars is to search for evidence of current or past life in the samples. Because of the remote possibility that the samples may contain life forms that are hazardous to the terrestrial biosphere, the National Research Council has recommended that all samples returned from Mars be kept under strict biological containment until tests show that they can safely be released to other laboratories. It is possible that Mars samples may contain only scarce or subtle traces of life or prebiotic chemistry that could readily be overwhelmed by terrestrial contamination. Thus, the facilities used to contain, process, and analyze samples from Mars must have a combination of high-level biocontainment and organic / inorganic chemical cleanliness that is unprecedented. We have been conducting feasibility studies and developing designs for a facility that would be at least as capable as current maximum containment BSL-4 (BioSafety Level 4) laboratories, while simultaneously maintaining cleanliness levels exceeding those of the cleanest electronics manufacturing labs. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samp les require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation Laboratory includes a new- generation glovebox equipped with a robotic arm to evaluate the usability of robotic and teleoperated systems to perform curatorial tasks. The laboratory also contains equipment for precision cleaning and the measurement of trace organic contamination.

  7. Hospital outpatient perceptions of the physical environment of waiting areas: the role of patient characteristics on atmospherics in one academic medical center

    PubMed Central

    Tsai, Chun-Yen; Wang, Mu-Chia; Liao, Wei-Tsen; Lu, Jui-Heng; Sun, Pi-hung; Lin, Blossom Yen-Ju; Breen, Gerald-Mark

    2007-01-01

    Background This study examines hospital outpatient perceptions of the physical environment of the outpatient waiting areas in one medical center. The relationship of patient characteristics and their perceptions and needs for the outpatient waiting areas are also examined. Method The examined medical center consists of five main buildings which house seventeen primary waiting areas for the outpatient clinics of nine medical specialties: 1) Internal Medicine; 2) Surgery; 3) Ophthalmology; 4) Obstetrics-Gynecology and Pediatrics; 5) Chinese Medicine; 6) Otolaryngology; 7) Orthopedics; 8) Family Medicine; and 9) Dermatology. A 15-item structured questionnaire was developed to rate patient satisfaction covering the four dimensions of the physical environments of the outpatient waiting areas: 1) visual environment; 2) hearing environment; 3) body contact environment; and 4) cleanliness. The survey was conducted between November 28, 2005 and December 8, 2005. A total of 680 outpatients responded. Descriptive, univariate, and multiple regression analyses were applied in this study. Results All of the 15 items were ranked as relatively high with a range from 3.362 to 4.010, with a neutral score of 3. Using a principal component analysis' summated scores of four constructed dimensions of patient satisfaction with the physical environments (i.e. visual environment, hearing environment, body contact environment, and cleanliness), multiple regression analyses revealed that patient satisfaction with the physical environment of outpatient waiting areas was associated with gender, age, visiting frequency, and visiting time. Conclusion Patients' socio-demographics and context backgrounds demonstrated to have effects on their satisfaction with the physical environment of outpatient waiting areas. In addition to noticing the overall rankings for less satisfactory items, what should receive further attention is the consideration of the patients' personal characteristics when redesigning more comfortable and customized physical environments of waiting areas. PMID:18053239

  8. College clinic service quality and patient satisfaction.

    PubMed

    Deshwal, Pankaj; Ranjan, Vini; Mittal, Geetika

    2014-01-01

    The purpose of this paper is to identify the service quality dimensions that play an important role in patient satisfaction in campus clinics in Delhi; assess student satisfaction with service; and suggests ways to improve areas of dissatisfaction. A questionnaire was distributed to students who had completed at least two consultations at the college clinic. Convenience sampling was used to approach respondents. The questionnaire uses modified SERVQUAL and other instruments, including original dimensions and those constructed through detailed discussions. Factor analyses, reliability tests and the Kaiser-Meyer-Olkin measure of sampling adequacy were conducted. The final sample had a total of 445 respondents. After factor analysis, the authors found that the dimensions affecting patient satisfaction are: staff professionalism; clinic staff reliability; clinic accessibility and basic facilities; tangibles; cleanliness; awareness of the clinic/diseases and how clinic staff deals with emergencies. Most students were satisfied with the professionalism of the clinic staff. More than 70 percent of the respondents reported that the clinic staff paid good attention to them. The campus clinic was deemed reliable by more than 50 percent of respondents. The students found the clinic's location convenient, with more than 50 percent supporting its location. However, there was dissatisfaction among the students regarding the tangibles of the clinic, with more than 50 percent favoring upgrading. There was satisfaction among the respondents regarding the availability of the doctor after clinic hours, but contact details for the clinic staff were not easily accessible on campus. More than 60 percent of respondents were satisfied with the cleanliness of the campus clinic. More than 50 percent felt that the campus clinic was not equipped to deal with emergencies efficiently. At the same time, 90 percent of respondents reported the availability of referral facilities in case of emergencies. The authors believe that this is the first study conducted to assess patient satisfaction in the campus clinics of engineering institutes in Delhi region. This paper provides valuable information to college clinic administrators.

  9. Social and Physical Environmental Factors Influencing Adolescents' Physical Activity in Urban Public Open Spaces: A Qualitative Study Using Walk-Along Interviews.

    PubMed

    Van Hecke, Linde; Deforche, Benedicte; Van Dyck, Delfien; De Bourdeaudhuij, Ilse; Veitch, Jenny; Van Cauwenberg, Jelle

    2016-01-01

    Most previous studies examining physical activity in Public Open Spaces (POS) focused solely on the physical environment. However, according to socio-ecological models the social environment is important as well. The aim of this study was to determine which social and physical environmental factors affect adolescents' visitation and physical activity in POS in low-income neighbourhoods. Since current knowledge on this topic is limited, especially in Europe, qualitative walk-along interviews were used to obtain detailed and context-specific information. Participants (n = 30, aged 12-16 years, 64% boys) were recruited in POS in low-income neighbourhoods in Brussels, Ghent and Antwerp (Belgium). Participants were interviewed while walking in the POS with the interviewer. Using this method, the interviewer could observe and ask questions while the participant was actually experiencing the environment. All audio-recorded interviews were transcribed and analysed using Nvivo 10 software and thematic analysis was used to derive categories and subcategories using a grounded theory approach. The most important subcategories that were supportive of visiting POS and performing physical activity in POS were; accessibility by foot/bicycle/public transport, located close to home/school, presence of (active) friends and family, cleanliness of the POS and features, availability of sport and play facilities, large open spaces and beautiful sceneries. The most important subcategories that were unsupportive of visiting POS and physical activity in POS were; presence of undesirable users (drug users, gangs and homeless people), the behaviour of other users and the cleanliness of the POS and features. Social factors appeared often more influential than physical factors, however, it was the combination of social and physical factors that affected adolescents' behaviour in POS. Easily accessible POS with high quality features in the proximity of adolescents' home or school may stimulate physical activity, if adolescents also experience a safe and familiar social environment.

  10. Social and Physical Environmental Factors Influencing Adolescents’ Physical Activity in Urban Public Open Spaces: A Qualitative Study Using Walk-Along Interviews

    PubMed Central

    Van Hecke, Linde; Deforche, Benedicte; Van Dyck, Delfien; De Bourdeaudhuij, Ilse; Veitch, Jenny; Van Cauwenberg, Jelle

    2016-01-01

    Most previous studies examining physical activity in Public Open Spaces (POS) focused solely on the physical environment. However, according to socio-ecological models the social environment is important as well. The aim of this study was to determine which social and physical environmental factors affect adolescents’ visitation and physical activity in POS in low-income neighbourhoods. Since current knowledge on this topic is limited, especially in Europe, qualitative walk-along interviews were used to obtain detailed and context-specific information. Participants (n = 30, aged 12–16 years, 64% boys) were recruited in POS in low-income neighbourhoods in Brussels, Ghent and Antwerp (Belgium). Participants were interviewed while walking in the POS with the interviewer. Using this method, the interviewer could observe and ask questions while the participant was actually experiencing the environment. All audio-recorded interviews were transcribed and analysed using Nvivo 10 software and thematic analysis was used to derive categories and subcategories using a grounded theory approach. The most important subcategories that were supportive of visiting POS and performing physical activity in POS were; accessibility by foot/bicycle/public transport, located close to home/school, presence of (active) friends and family, cleanliness of the POS and features, availability of sport and play facilities, large open spaces and beautiful sceneries. The most important subcategories that were unsupportive of visiting POS and physical activity in POS were; presence of undesirable users (drug users, gangs and homeless people), the behaviour of other users and the cleanliness of the POS and features. Social factors appeared often more influential than physical factors, however, it was the combination of social and physical factors that affected adolescents’ behaviour in POS. Easily accessible POS with high quality features in the proximity of adolescents’ home or school may stimulate physical activity, if adolescents also experience a safe and familiar social environment. PMID:27214385

  11. Evaluation of microbiological, cellular and risk factors associated with subclinical mastitis in female buffaloes

    PubMed Central

    de Oliveira Moura, Emmanuella; do Nascimento Rangel, Adriano Henrique; de Melo, Maria Celeste Nunes; Borba, Luiz Henrique Fernandes; de Lima Júnior, Dorgival Morais; Novaes, Luciano Patto; Urbano, Stela Antas; de Andrade Neto, Júlio César

    2017-01-01

    Objective This study aimed to evaluate the microbiological and cellular milk profile for the diagnosis of subclinical mastitis in female buffaloes and to assess risk factors for predisposition of the disease. Methods Analyses were carried out by standard plate count (SPC), identification of species and antibiotic resistance, somatic cell count (SCC), electrical electrical conductivity of milk (ECM), and lactoferrin content in milk. Teat cups were swabbed to evaluate risk factors, observing hyperkeratosis, milking vacuum pressure and cleanliness of the site. Hence, 30 female buffaloes were randomly selected (15 from a group in early lactation and 15 in late lactation). Results The most common bacteria in the microbiological examination were Staphylococcus spp., Streptococcus spp. and Corynebacterium sp. In the antibiotic sensitivity test, 10 (58.82%) of the 17 antibiotics tested were sensitive to all isolates, and resistant bacteria were Streptococcus uberis, Streptococcus dysgalactiae, Streptococcus haemolyticus, and Escherichia coli. It was observed that positive samples in the microbiological examination showed total bacterial count between 9.10×103 to 6.94×106 colony forming units/mL, SCC between 42,000 to 4,320,000 cells/mL and ECM ranging from 1.85 to 7.40 mS/cm. It was also found that the teat cups had high microbial counts indicating poor hygiene, and even faults in the cleanliness of the animals’ waiting room were observed. It is concluded that values of SCC above 537,000 cells/mL and ECM above 3.0 mS/mL are indications of mammary gland infection for this herd; however, the association of these values with a microbiological analysis is necessary to more accurately evaluate the health status of mammary glands with subclinical mastitis. Conclusion Through phenotypic characterization of bacteria involved in the samples, the genera Staphylococcus spp., Streptococcus spp., and Corynebacterimum bovis were the most prevalent in this study. Faults in environment and equipment hygienization are factors that are directly associated with mastitis. PMID:28183165

  12. Dairy farms testing positive for Mycobacterium avium ssp. paratuberculosis have poorer hygiene practices and are less cautious when purchasing cattle than test-negative herds.

    PubMed

    Wolf, R; Barkema, H W; De Buck, J; Orsel, K

    2016-06-01

    Mycobacterium avium ssp. paratuberculosis (MAP), the causative agent of Johne's disease, is present on most dairy farms in Alberta, causing economic losses and presenting a potential public health concern. The objective of this cross-sectional study was to identify risk factors for Alberta dairy herds being MAP-positive based on environmental samples (ES). Risk assessments were conducted and ES were collected on 354 Alberta dairy farms (62% of eligible producers) voluntarily participating in the Alberta Johne's Disease Initiative. In univariate logistic regression, risk factors addressing animal and pen hygiene, as well as the use of feeding equipment to remove manure and manure application on pastures, were all associated with the number of positive ES. Furthermore, based on factor analysis, risk factors were clustered and could be summarized as 4 independent factors: (1) animal, pen, and feeder contamination; (2) shared equipment and pasture contamination; (3) calf diet; and (4) cattle purchase. Using these factor scores as independent variables in multivariate logistic regression models, a 1-unit increase in animal, pen, and feeder contamination resulted in 1.31 times higher odds of having at least 1 positive ES. Furthermore, a 1-unit increase in cattle purchase also resulted in 1.31 times the odds of having at least 1 positive ES. Finally, a 100-cow increase in herd size resulted in an odds ratio of 2.1 for having at least 1 positive ES. In conclusion, cleanliness of animals, pens, and feeders, as well as cattle purchase practices, affected risk of herd infection with MAP. Therefore, improvements in those management practices should be the focus of effective tools to control MAP on dairy farms. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Polyethylene glycol powder solution versus senna for bowel preparation for colonoscopy in children.

    PubMed

    Terry, Natalie A; Chen-Lim, Mei Lin; Ely, Elizabeth; Jatla, Muralidhar; Ciavardone, Denise; Esch, Salina; Farace, Lisa; Jannelli, Frances; Puma, Anita; Carlow, Dean; Mamula, Petar

    2013-02-01

    Safety and effectiveness of large-volume polyethylene glycol-based solution (PEG-ES) have been documented, but the taste and volume can be barriers to successful colonoscopy preparation. Efficacy and safety of small-volume electrolyte-free (PEG-P) preparation (Miralax) for colonoscopy preparation have been rarely studied, although presently used at many pediatric centers. The primary objective of the present study was to determine whether PEG-P results in a more efficacious and safe colonoscopy preparation as compared with senna. The study design was prospective, randomized, and single-blinded. Patients ages 6 to 21 years were randomized to a 2-day clean-out regimen of PEG-P at a dose of 1.5 g/kg divided twice per day for 2 days versus senna 15 mL daily (ages 6-12) or 30 mL daily (ages 12-21) for 2 days. Both preparations required 1 day of clear liquids whereas senna preparation required an additional day of full liquid diet. A blinded endoscopist graded the quality of preparation with a standardized cleanliness tool (Aronchick scale). Serum chemistry panels were obtained. Patients or parents rated symptoms and ease of preparation. The anticipated number of subjects was 166; however, the interim analysis demonstrated inferiority of senna preparation. Thirty patients were evaluated in the present study. Of the patients in the PEG-P arm, 88% (14/16) received an excellent/good score compared with 29% (4/14), with the senna preparation (P = 0.0022). Both preparations were well-tolerated by patient-graded ease of preparation. Demographics and laboratory values did not differ significantly across the 2 groups. No serious adverse events were noted. PEG-P is an effective colonoscopy preparation whereas senna preparation was insufficient. Both were well-tolerated and appear safe in a pediatric population.

  14. A Longitudinal Study to Assess the Role of Sanitary Inspections in Improving the Hygiene and Food Safety of Eating Establishments in a Tertiary Care Hospital of North India

    PubMed Central

    Dudeja, Puja; Singh, Amarjeet

    2017-01-01

    Introduction: Food safety inspections serve two purposes; determine compliance with the law and gather evidence for enforcement if there is noncompliance. The present study was conducted to assess the role of regular inspections on food safety in hospital premises. Methodology: This was an intervention based before and after study. A tool was prepared based on the Food Safety and Standards Regulations (FSSR) (in India) 2011. This included major, critical, and highly critical domains. Each item in the tool scored between 1 and 3 (poor, satisfactory, and good). Based on this, each eating establishment (EE) was given a score on conformance to FSSR 2011. Monthly inspection was made over a year and corrective actions were suggested. Results: The minimum preintervention score was (41.28%), and maximum was (77.25%). There was no significant association between type of meal services and score EE (P > 0.05). Higher proportion of EEs within the hospital building had a satisfactory and good score as compared to EEs outside the hospital building but within hospital premises (P < 0.05). Postintervention, there was a significant change (increase) in the scores of EEs. There was a significant increase in mean scores of EEs under major domains namely maintenance, layout of equipment, monitoring an detection, and elimination of food sources to the pests. Under critical and highly critical domains personal cleanliness, training, and self-inspection by food business operators improved significantly. Conclusion: Regular inspections can improve the food safety standards in EEs. PMID:29184325

  15. A Longitudinal Study to Assess the Role of Sanitary Inspections in Improving the Hygiene and Food Safety of Eating Establishments in a Tertiary Care Hospital of North India.

    PubMed

    Dudeja, Puja; Singh, Amarjeet

    2017-01-01

    Food safety inspections serve two purposes; determine compliance with the law and gather evidence for enforcement if there is noncompliance. The present study was conducted to assess the role of regular inspections on food safety in hospital premises. This was an intervention based before and after study. A tool was prepared based on the Food Safety and Standards Regulations (FSSR) (in India) 2011. This included major, critical, and highly critical domains. Each item in the tool scored between 1 and 3 (poor, satisfactory, and good). Based on this, each eating establishment (EE) was given a score on conformance to FSSR 2011. Monthly inspection was made over a year and corrective actions were suggested. The minimum preintervention score was (41.28%), and maximum was (77.25%). There was no significant association between type of meal services and score EE ( P > 0.05). Higher proportion of EEs within the hospital building had a satisfactory and good score as compared to EEs outside the hospital building but within hospital premises ( P < 0.05). Postintervention, there was a significant change (increase) in the scores of EEs. There was a significant increase in mean scores of EEs under major domains namely maintenance, layout of equipment, monitoring an detection, and elimination of food sources to the pests. Under critical and highly critical domains personal cleanliness, training, and self-inspection by food business operators improved significantly. Regular inspections can improve the food safety standards in EEs.

  16. Effect of water, sanitation, and hygiene on the prevention of trachoma: a systematic review and meta-analysis.

    PubMed

    Stocks, Meredith E; Ogden, Stephanie; Haddad, Danny; Addiss, David G; McGuire, Courtney; Freeman, Matthew C

    2014-02-01

    Trachoma is the world's leading cause of infectious blindness. The World Health Organization (WHO) has endorsed the SAFE strategy in order to eliminate blindness due to trachoma by 2020 through "surgery," "antibiotics," "facial cleanliness," and "environmental improvement." While the S and A components have been widely implemented, evidence and specific targets are lacking for the F and E components, of which water, sanitation, and hygiene (WASH) are critical elements. Data on the impact of WASH on trachoma are needed to support policy and program recommendations. Our objective was to systematically review the literature and conduct meta-analyses where possible to report the effects of WASH conditions on trachoma and identify research gaps. We systematically searched PubMed, Embase, ISI Web of Knowledge, MedCarib, Lilacs, REPIDISCA, DESASTRES, and African Index Medicus databases through October 27, 2013 with no restrictions on language or year of publication. Studies were eligible for inclusion if they reported a measure of the effect of WASH on trachoma, either active disease indicated by observed signs of trachomatous inflammation or Chlamydia trachomatis infection diagnosed using PCR. We identified 86 studies that reported a measure of the effect of WASH on trachoma. To evaluate study quality, we developed a set of criteria derived from the GRADE methodology. Publication bias was assessed using funnel plots. If three or more studies reported measures of effect for a comparable WASH exposure and trachoma outcome, we conducted a random-effects meta-analysis. We conducted 15 meta-analyses for specific exposure-outcome pairs. Access to sanitation was associated with lower trachoma as measured by the presence of trachomatous inflammation-follicular or trachomatous inflammation-intense (TF/TI) (odds ratio [OR] 0.85, 95% CI 0.75-0.95) and C. trachomatis infection (OR 0.67, 95% CI 0.55-0.78). Having a clean face was significantly associated with reduced odds of TF/TI (OR 0.42, 95% CI 0.32-0.52), as were facial cleanliness indicators lack of ocular discharge (OR 0.42, 95% CI 0.23-0.61) and lack of nasal discharge (OR 0.62, 95% CI 0.52-0.72). Facial cleanliness indicators were also associated with reduced odds of C. trachomatis infection: lack of ocular discharge (OR 0.40, 95% CI 0.31-0.49) and lack of nasal discharge (OR 0.56, 95% CI 0.37-0.76). Other hygiene factors found to be significantly associated with reduced TF/TI included face washing at least once daily (OR 0.76, 95% CI 0.57-0.96), face washing at least twice daily (OR 0.85, 95% CI 0.80-0.90), soap use (OR 0.76, 95% CI 0.59-0.93), towel use (OR 0.65, 95% CI 0.53-0.78), and daily bathing practices (OR 0.76, 95% CI 0.53-0.99). Living within 1 km of a water source was not found to be significantly associated with TF/TI or C. trachomatis infection, and the use of sanitation facilities was not found to be significantly associated with TF/TI. We found strong evidence to support F and E components of the SAFE strategy. Though limitations included moderate to high heterogenity, low study quality, and the lack of standard definitions, these findings support the importance of WASH in trachoma elimination strategies and the need for the development of standardized approaches to measuring WASH in trachoma control programs.

  17. American College of Surgeons Level I trauma centers outcomes do not correlate with patients' perception of hospital experience.

    PubMed

    Joseph, Bellal; Azim, Asad; O'Keeffe, Terence; Ibraheem, Kareem; Kulvatunyou, Narong; Tang, Andrew; Vercruysse, Gary; Friese, Randall; Latifi, Rifat; Rhee, Peter

    2017-04-01

    The Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) survey is a data collection methodology for measuring a patient's perception of his/her hospital experience, and it has been selected by the Centers of Medicare and Medicaid Services as the validated and transparent national survey tool with publicly available results. Since 2012, hospital reimbursements rates have been linked to HCAHPS data based on patient satisfaction scores. The aim of this study was, therefore, to assess whether HCAHPS scores of Level I trauma centers correlate with actual hospital performance. Retrospective analysis of the latest publicly available HCAHPS data (2014-2015) was performed. American College of Surgeons (ACS) verified Level I trauma centers for each state were identified from the ACS registry and then the following data points were collected for each hospital: HCAHPS linear mean scores regarding cleanliness of the hospital, doctor and nurse communication with the patient, staff responsiveness, pain management, overall hospital rating, and patient willingness to recommend the hospital. Our outcome measure were serious complication scores, failure-to-rescue (FTR) scores and readmission-after-discharge scores. Spearman correlation analysis was performed. A total of 119 ACS verified Level I trauma centers across 46 states were included. The median [IQR] overall hospital rating score for Level I trauma centers was 89 (87-90). The mean ± SD score for serious complication was 0.96 ± 0.266, FTR was 123.06 ± 22.5, and readmission after discharge was 15.71 ± 1.07. The Spearman correlation analysis showed that overall HCAHP-based hospital rating scores did not correlate with serious complications (correlation coefficient = 0.14 p = 0.125), FTR (correlation coefficient = -0.15 p = 0.073), or readmission after discharge (correlation coefficient = -0.18 p = 0.053). The findings of our study suggest that no correlation exists between HCAHPS patient satisfaction scores and hospital performance for Level I trauma centers. Consequently, the Centers of Medicare and Medicaid Services should reconsider hospital reimbursement decisions based on HCAHP patient satisfaction scores. Prognostic/epidemiologic study, level III; therapeutic study, level IV.

  18. Obsessive-compulsive symptoms in a normative Chinese sample of youth: prevalence, symptom dimensions, and factor structure of the Leyton Obsessional Inventory--Child Version.

    PubMed

    Sun, Jing; Boschen, Mark J; Farrell, Lara J; Buys, Nicholas; Li, Zhan-Jiang

    2014-08-01

    Chinese adolescents face life stresses from multiple sources, with higher levels of stress predictive of adolescent mental health outcomes, including in the area of obsessive-compulsive disorders (OCD). Valid assessment of OCD among this age group is therefore a critical need in China. This study aims to standardise the Chinese version of the Leyton short version scale for adolescents of secondary schools in order to assess this condition. Stratified randomly selected adolescents were selected from four high schools located in Beijing, China. The Chinese version of the Leyton scale was administered to 3221 secondary school students aged between 12 and 18 years. A high response rate was achieved, with 3185 adolescents responding to the survey (98.5 percent). Exploratory factor analysis (EFA) extracted four factors from the scale: compulsive thoughts, concerns of cleanliness, lucky number, repetitiveness and repeated checking. The four-factor structures were confirmed using Confirmatory Factor Analysis (CFA). Overall the four-factor structure had a good model fit and high levels of reliability for each individual dimension and reasonable content validity. Invariance analyses in unconstrained, factor loading, and error variance models demonstrated that the Leyton scale is invariant in relation to the presence or absence OCD, age and gender. Discriminant validity analysis demonstrated that the four-factor structure scale also had excellent ability to differentiate between OCD and non-OCD students, male and female students, and age groups. The dataset was a non-clinical sample of high school students, rather than a sample of individuals with OCD. Future research may examine symptom structure in clinical populations to assess whether this structure fits into both clinical and community population. The structure derived from the Leyton short version scale in a non-clinical secondary school sample of adolescents, suggests that a four-factor solution can be utilised as a screening tool to assess adolescents׳ psychopathological symptoms in the area of OCD in mainland Chinese non-clinical secondary school students. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. OSIRIS-REx Contamination Control Strategy and Implementation

    NASA Technical Reports Server (NTRS)

    Dworkin, J. P.; Adelman, L. A.; Ajluni, T.; Andronikov, A. V.; Aponte, J. C.; Bartels, A. E.; Beshore, E.; Bierhaus, E. B.; Brucato, J. R.; Bryan, B. H.; hide

    2017-01-01

    OSIRIS-REx will return pristine samples of carbonaceous asteroid Bennu. This manuscript describes how pristine was defined based on expectations of Bennu and on a realistic understanding of what is achievable with a constrained schedule and budget, and how that definition flowed to requirements and implementation. To return a pristine sample, the OSIRIS-REx spacecraft sampling hardware was maintained at Level 100 A/2 and less than 180 nanograms per square centimeter of amino acids and hydrazine on the sampler head through precision cleaning, control of materials, and vigilance. Contamination is further characterized via witness material exposed to the spacecraft assembly and testing environment as well as in space. This characterization provided knowledge of the expected background and will be used in conjunction with archived spacecraft components for comparison with the samples when they are delivered to Earth for analysis. Most of all, the cleanliness of the OSIRIS-REx spacecraft was achieved through communication between scientists, engineers, managers, and technicians.

  20. Aqueous cleaning and verification processes for precision cleaning of small parts

    NASA Technical Reports Server (NTRS)

    Allen, Gale J.; Fishell, Kenneth A.

    1995-01-01

    The NASA Kennedy Space Center (KSC) Materials Science Laboratory (MSL) has developed a totally aqueous process for precision cleaning and verification of small components. In 1990 the Precision Cleaning Facility at KSC used approximately 228,000 kg (500,000 lbs) of chlorofluorocarbon (CFC) 113 in the cleaning operations. It is estimated that current CFC 113 usage has been reduced by 75 percent and it is projected that a 90 percent reduction will be achieved by the end of calendar year 1994. The cleaning process developed utilizes aqueous degreasers, aqueous surfactants, and ultrasonics in the cleaning operation and an aqueous surfactant, ultrasonics, and Total Organic Carbon Analyzer (TOCA) in the nonvolatile residue (NVR) and particulate analysis for verification of cleanliness. The cleaning and verification process is presented in its entirety, with comparison to the CFC 113 cleaning and verification process, including economic and labor costs/savings.

  1. OSIRIS-REx Contamination Control Strategy and Implementation

    NASA Astrophysics Data System (ADS)

    Dworkin, J. P.; Adelman, L. A.; Ajluni, T.; Andronikov, A. V.; Aponte, J. C.; Bartels, A. E.; Beshore, E.; Bierhaus, E. B.; Brucato, J. R.; Bryan, B. H.; Burton, A. S.; Callahan, M. P.; Castro-Wallace, S. L.; Clark, B. C.; Clemett, S. J.; Connolly, H. C.; Cutlip, W. E.; Daly, S. M.; Elliott, V. E.; Elsila, J. E.; Enos, H. L.; Everett, D. F.; Franchi, I. A.; Glavin, D. P.; Graham, H. V.; Hendershot, J. E.; Harris, J. W.; Hill, S. L.; Hildebrand, A. R.; Jayne, G. O.; Jenkens, R. W.; Johnson, K. S.; Kirsch, J. S.; Lauretta, D. S.; Lewis, A. S.; Loiacono, J. J.; Lorentson, C. C.; Marshall, J. R.; Martin, M. G.; Matthias, L. L.; McLain, H. L.; Messenger, S. R.; Mink, R. G.; Moore, J. L.; Nakamura-Messenger, K.; Nuth, J. A.; Owens, C. V.; Parish, C. L.; Perkins, B. D.; Pryzby, M. S.; Reigle, C. A.; Righter, K.; Rizk, B.; Russell, J. F.; Sandford, S. A.; Schepis, J. P.; Songer, J.; Sovinski, M. F.; Stahl, S. E.; Thomas-Keprta, K.; Vellinga, J. M.; Walker, M. S.

    2018-02-01

    OSIRIS-REx will return pristine samples of carbonaceous asteroid Bennu. This article describes how pristine was defined based on expectations of Bennu and on a realistic understanding of what is achievable with a constrained schedule and budget, and how that definition flowed to requirements and implementation. To return a pristine sample, the OSIRIS-REx spacecraft sampling hardware was maintained at level 100 A/2 and <180 ng/cm2 of amino acids and hydrazine on the sampler head through precision cleaning, control of materials, and vigilance. Contamination is further characterized via witness material exposed to the spacecraft assembly and testing environment as well as in space. This characterization provided knowledge of the expected background and will be used in conjunction with archived spacecraft components for comparison with the samples when they are delivered to Earth for analysis. Most of all, the cleanliness of the OSIRIS-REx spacecraft was achieved through communication among scientists, engineers, managers, and technicians.

  2. OSIRIS-REx Contamination Control Strategy and Implementation

    NASA Technical Reports Server (NTRS)

    Dworkin, J. P.; Adelman, L. A.; Ajluni, T. M.; Andronikov, A. V.; Aponte, J. S.; Bartels, A. E.; Beshore, E.; Bierhaus, E. B.; Brucato, J. R.; Bryan, B. H.; hide

    2017-01-01

    OSIRIS-REx will return pristine samples of carbonaceous asteroid Bennu. This article describes how pristine was defined based on expectations of Bennu and on a realistic understanding of what is achievable with a constrained schedule and budget, and how that definition flowed to requirements and implementation. To return a pristine sample, the OSIRIS-REx spacecraft sampling hardware was maintained at level 100 A/2 and less than 180 ng/cm(exp 2) of amino acids and hydrazine on the sampler head through precision cleaning, control of materials, and vigilance. Contamination is further characterized via witness material exposed to the spacecraft assembly and testing environment as well as in space. This characterization provided knowledge of the expected background and will be used in conjunction with archived spacecraft components for comparison with the samples when they are delivered to Earth for analysis. Most of all, the cleanliness of the OSIRIS-REx spacecraft was achieved through communication among scientists, engineers, managers, and technicians.

  3. The conceptions of care among family caregivers of persons living with HIV/AIDS in Addis Ababa, Ethiopia.

    PubMed

    Aga, Fekadu; Kylmä, Jari; Nikkonen, Merja

    2009-01-01

    This focused ethnographic study explores and describes the conceptions of care among family caregivers of people living with HIV/AIDS (PLWAs) in Addis Ababa, Ethiopia. Leininger's theory of culture care diversity and universality is the conceptual anchor of this ethnographic study. Using semistructured interviews and participant observation, 6 key informants and 12 general informants were interviewed in their home in Amharic language. Data were analyzed in Amharic using Leininger's phases of ethnonursing analysis for qualitative data and then translated to English. Four major themes representing family caregivers' conceptions of care were identified: nourishing the PLWA while struggling with poverty, maintenance of cleanliness and hygiene of the person and surroundings, comforting the PLWA, and sacrificing self to sustain the PLWA. Valuable data were gathered about the family caregivers' conceptions of care. Nurses can use this knowledge to design and provide culturally congruent care to family caregivers and PLWAs in the community.

  4. A Dynamic Approach to Monitoring Particle Fallout in a Cleanroom Environment

    NASA Technical Reports Server (NTRS)

    Perry, Radford L., III

    2010-01-01

    This slide presentation discusses a mathematical model to monitor particle fallout in a cleanroom. "Cleanliness levels" do not lead to increases with regards to cleanroom type or time because the levels are not linear. Activity level, impacts the cleanroom class. The numerical method presented leads to a simple Class-hour formulation, that allows for dynamic monitoring of the particle using a standard air particle counter.

  5. Army’s Evalution of Aviation Fuel Contaminants Using Electronic Sensors

    DTIC Science & Technology

    2012-04-13

    and free water contamination challenges, testing of mechanical integrity in response to pressure and material compatibility. 15. SUBJECT TERMS 16...4406 • Turbidity/photometers used in beer/ wine industry • Challenge – Being able to determine both particulate and water contamination...looking at real-time methods for determining fuel cleanliness • Some “re-inventing of the wheel” occurred • Products went to the field without

  6. Paint and Surface Preparation Training Program for Shipyard Personnel

    DTIC Science & Technology

    1979-01-01

    major anti- fouling ingredient in the various coatings which are used on shipbottoms -- bituminous, vinyl, and chlorinated rubber. Organotin compounds ...Improper cleaning of surface or spray gun; dirty work area. Remedy: In most cases, sanding and recoating is sufficient. Blasting may be indicated in... compounds . When using air-fed respirators, the source of air must be monitored and controlled. It must meet specifications defining cleanliness and minimal

  7. Chemical, Biological, and Radiological (CBR) Contamination Survivability, Small Items of Equipment

    DTIC Science & Technology

    2012-06-22

    thickness (number of coats), paint condition, and surface cleanliness (mud, grease, and other). j. Pretest (baseline) and posttest (30 days after...survivability testing of small items of mission-essential (ME) Army materiel. Small items, for example , include personal gear, small arms, radios...their effects. An example would be the age of the paint on the surface (aged, new, etc.). f. The only current mechanism for converting agent mass

  8. The Effects of Verbal Disgust- and Threat-Related Information about Novel Animals on Disgust and Fear Beliefs and Avoidance in Children

    ERIC Educational Resources Information Center

    Muris, Peter; Huijding, Jorg; Mayer, Birgit; Leemreis, Willem; Passchier, Stefanie; Bouwmeester, Samantha

    2009-01-01

    Disgust is a basic emotion that is thought to play a role in the etiology of certain types of specific phobias, like animal phobias. Two experiments were conducted in which 9- to 14-year-old children were exposed to disgust-related, cleanliness-related, and threat-related information about unknown animals. It was investigated to what extent these…

  9. Chemical and Biological Contamination Survivability (CBCS), Large Item Exteriors. Test Operations Procedure

    DTIC Science & Technology

    2011-03-21

    and may be difficult to decontaminate. n. Pretest (baseline) and posttest (30 days after the first contamination and/or other defined long-term...be reported in a form that can be compared with pretest and posttest hardness functional performance data. 4.1.6.2 Decontaminability. a...exterior materials of construction, paint type, and surface condition ( pretest and posttest ), including cleanliness (mud, grease, and other

  10. Chemical, Biological, and Radiological (CBR) Contamination Survivability: Large Item Interiors

    DTIC Science & Technology

    2012-06-22

    materials of construction, paint type, and surface condition ( pretest and posttest ), including cleanliness (mud, grease, etc.). Photographs should be...35 g. Pretest and posttest ME functional performance characteristics (when measured) used as the measure of the SUT’s mission performance before and...materials and their finishes will be reported in a form that can be compared with pretest and posttest hardness functional performance data. 6.2 Chemical

  11. A "clean cigarette" for a clean nation: a case study of Salem Pianissimo in Japan.

    PubMed

    Assunta, M; Chapman, S

    2004-12-01

    To illustrate, through internal industry documents, how RJ Reynolds exploited the concerns of the Japanese society about cleanliness to market the concept of cleaner, implicitly healthier cigarettes in Japan. Systematic keyword and opportunistic website searches of formerly private internal industry documents. Industry documents show that RJ Reynolds developed marketing plans based upon their cultural assumptions of Japanese people as fastidious about hygiene and manners, and with relatively high penchants to try new products. RJ Reynolds found there was also a growing concern for health, the environment, and smokers were conscious about annoying others. Deodorised consumer products were one of Japan's biggest trends. These characteristics presented RJ Reynolds with a profitable formula for marketing Salem Pianissimo, a clean cigarette with less smell and smoke. Salem Pianissimo, a 100 mm cigarette claiming to contain 1 mg tar and 0.1 mg nicotine, targeted women since menthol cigarettes were popular among 18-24 year old female smokers, although Japan's law prohibited those below 20 years to smoke and the tobacco industry had a voluntary code disallowing advertising to women and youth. RJ Reynolds successfully launched its clean cigarette, Salem Pianissimo, in Japan aiming to exploit perceived cultural characteristics such as a penchant for cleanliness, an eagerness to try new products, and social harmony.

  12. Evaluation of Contaminant-Promoted Ignition in Scuba Equipment and Breathing Gas Delivery Systems

    NASA Technical Reports Server (NTRS)

    Forsyth, Elliott T.; Durkin, Robert; Beeson, Harold D.

    2000-01-01

    As the underwater diving industry continues to use greater concentrations of oxygen in their scuba systems, ignition of contaminants in these systems becomes a greater concern. Breathing gas makeup and distribution systems typically combine pure oxygen with various diluents to supply high-pressure cylinders for scuba applications. The hazards associated with these applications of oxygen and NITROX (oxygen and nitrogen mixture) gases require an evaluation of inherent contaminant levels and their associated promoted-ignition thresholds in these environments. In this study, several scuba component assemblies were tested after one year of use at the NASA Johnson Space Center Neutral Buoyancy Lab. The components were rapidly impacted with 50% NITROX gas to demonstrate their ignition resistance, then disassembled to evaluate their cleanliness. A follow-up study was then performed on the ignition thresholds of hydrocarbon-bascd oil films in oxygen and NITROX environments in an attempt to define the cleaning requirements for these systems. Stainless steel tubes were contaminated and verified to known levels and placed in a pneumatic impact test system where they were rapidly pressurized with the test gas. Ignitions were determined using a photodiode connected to the end of the contaminated tube. The results of the scuba component tests, cleanliness evaluation, and contaminant ignition study are discussed and compared for 50% NITROX and 100% oxygen environments.

  13. Enhancing community knowledge and health behaviors to eliminate blinding trachoma in Mali using radio messaging as a strategy.

    PubMed

    Bamani, Sanoussi; Toubali, Emily; Diarra, Sadio; Goita, Seydou; Berté, Zana; Coulibaly, Famolo; Sangaré, Hama; Tuinsma, Marjon; Zhang, Yaobi; Dembelé, Benoit; Melvin, Palesa; MacArthur, Chad

    2013-04-01

    The National Blindness Prevention Program in Mali has broadcast messages on the radio about trachoma as part of the country's trachoma elimination strategy since 2008. In 2011, a radio impact survey using multi-stage cluster sampling was conducted in the regions of Kayes and Segou to assess radio listening habits, coverage of the broadcasts, community knowledge and behavior specific to trachoma and facial cleanliness of children. Radio access and listening were high, with 60% of respondents having heard a message on the radio about trachoma. The majority of respondents knew about trachoma, its root causes, its impact on health and prevention measures. Additionally, 66% reported washing their children's faces more than or equal to twice/day and 94% reported latrine disposal of feces. A high percentage of persons who gave a positive response to knowledge and behavior questions reported hearing the trachoma messages on the radio with 60% reporting that the radio is where they learned about trachoma. There was no significant difference in facial cleanliness when comparing children whose primary caregiver had/had not heard the trachoma messages. Next steps include revising the current messages to include more focused behavior change messaging and to engage in a more robust use of community radios.

  14. Organic Contamination Baseline Study in NASA Johnson Space Center Astromaterials Curation Laboratories

    NASA Technical Reports Server (NTRS)

    Calaway, Michael J.; Allen, Carlton C.; Allton, Judith H.

    2014-01-01

    Future robotic and human spaceflight missions to the Moon, Mars, asteroids, and comets will require curating astromaterial samples with minimal inorganic and organic contamination to preserve the scientific integrity of each sample. 21st century sample return missions will focus on strict protocols for reducing organic contamination that have not been seen since the Apollo manned lunar landing program. To properly curate these materials, the Astromaterials Acquisition and Curation Office under the Astromaterial Research and Exploration Science Directorate at NASA Johnson Space Center houses and protects all extraterrestrial materials brought back to Earth that are controlled by the United States government. During fiscal year 2012, we conducted a year-long project to compile historical documentation and laboratory tests involving organic investigations at these facilities. In addition, we developed a plan to determine the current state of organic cleanliness in curation laboratories housing astromaterials. This was accomplished by focusing on current procedures and protocols for cleaning, sample handling, and storage. While the intention of this report is to give a comprehensive overview of the current state of organic cleanliness in JSC curation laboratories, it also provides a baseline for determining whether our cleaning procedures and sample handling protocols need to be adapted and/or augmented to meet the new requirements for future human spaceflight and robotic sample return missions.

  15. Standard operating procedures for maintaining cleanliness in a novel compact facility for breeding SPF mice.

    PubMed

    Sakuma, Kenji; Hayashi, Susumu; Otokuni, Keiko; Matsumoto, Izumi; Matsuoka, Hideaki; Saito, Mikako

    2013-11-01

    A compact facility for SPF mice that was not equipped with a large autoclave used disposable mouse cages instead. The SPF clean room was 5.7 × 8.1 × 2.7 m(3), with a breeding capacity of 1008 cages (168 cages on each of 6 racks). We evaluated cleanliness in the SPF clean room under the conditions of an occupation rate of 60% to 70% and typically 1 to 3 personnel (maximum, 4 to 6) daily on weekdays. Personnel were taught standard procedures and received training beforehand. During the 15-mo study period, the maximal concentration of airborne particles 0.5 μm or larger was 1.0 × 10(4) particles/m3 and that of particles 5.0 μm or larger was 5.0 × 10(2) particles/m(3)--well below the maximal permissible concentrations of 3.52 × 10(5) and 2.93 × 10(3) particles/m(3), respectively. During the study period, no mice exhibited clinical symptoms of infection. Testing of 2 representative, overtly healthy mice for 16 pathogens including Staphylococcus aureus, Pseudomonas aeruginosa, and Helicobacter bilis failed to detect any of the target agents. The current study demonstrates the feasibility of the compact facility for breeding SPF mice in the academic environment.

  16. The Use of HFC (CFC Free) Processes at the NASA Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Ross, Richard H.

    1997-01-01

    The search for ozone depleting alternative chemicals was heightened when, in 1990, the more than 65 countries that had signed the Montreal Protocol agreed to phase out completely by the year 2000. In 1992, then-president Bush advanced this date for the United States to January l, 1996. In 1991, it was realized that the planned phase out and eventual elimination of ozone depleting chemicals imposed by the Montreal Protocol and the resulting Clean Air Act (CAA) amendments would impact the cleaning and testing of aerospace hardware at the NASA Stennis Space Center. Because of this regulation, the Test & Engineering Sciences Laboratory has been working on solvent conversion studies to replace CFC-113. Aerospace hardware and test equipment used in rocket propulsion systems require extreme cleanliness levels to function and maintain their integrity. Because the cleanliness of aerospace hardware will be affected by the elimination of CFC-113; alternate cleaning technologies, including the use of fluoridated solvents have been studied as potential replacements. Several aqueous processes have been identified for cleaning moderately sized components. However, no known aqueous alternative exists for cleaning and validating T&ME and complex geometry based hardware. This paper discusses the choices and the methodologies that were used to screen potential alternatives to CFC-113.

  17. Standard Operating Procedures for Maintaining Cleanliness in a Novel Compact Facility for Breeding SPF Mice

    PubMed Central

    Sakuma, Kenji; Hayashi, Susumu; Otokuni, Keiko; Matsumoto, Izumi; Matsuoka, Hideaki; Saito, Mikako

    2013-01-01

    A compact facility for SPF mice that was not equipped with a large autoclave used disposable mouse cages instead. The SPF clean room was 5.7 × 8.1 × 2.7 m3, with a breeding capacity of 1008 cages (168 cages on each of 6 racks). We evaluated cleanliness in the SPF clean room under the conditions of an occupation rate of 60% to 70% and typically 1 to 3 personnel (maximum, 4 to 6) daily on weekdays. Personnel were taught standard procedures and received training beforehand. During the 15-mo study period, the maximal concentration of airborne particles 0.5 μm or larger was 1.0 × 104 particles/m3 and that of particles 5.0 μm or larger was 5.0 × 102 particles/m3—well below the maximal permissible concentrations of 3.52 × 105 and 2.93 × 103 particles/m3, respectively. During the study period, no mice exhibited clinical symptoms of infection. Testing of 2 representative, overtly healthy mice for 16 pathogens including Staphylococcus aureus, Pseudomonas aeruginosa, and Helicobacter bilis failed to detect any of the target agents. The current study demonstrates the feasibility of the compact facility for breeding SPF mice in the academic environment. PMID:24351759

  18. Efficiency of light curing units in a government dental school.

    PubMed

    Nassar, Hani M; Ajaj, Reem; Hasanain, Fatin

    2018-01-01

    The light intensity of a light-curing unit is a crucial factor that affects the clinical longevity of resin composites. This study aimed to investigate the efficiency of light-curing units in use at a local governmental dental school for curing conventional and bulk-fill resin materials. A total of 166 light-curing units at three locations were examined, and the brand, type, clinic location, diameter of curing tip, tip cleanliness (using a visual score), and the output (in mW/cm 2 using a digital radiometer) were recorded. Only 23.5% of the units examined had clean tips, with the graduate student clinical area containing the highest percentage of clean tips. Further, tips with poor cleanliness score values were associated with significantly lower output intensities. A small percentage (9.4%) of units was capable of producing intensities higher than 1,200 mW/cm 2 and lower than 600 mW/cm 2 (7.6%). The majority of the low intensity units were located in the undergraduate student area, which also contained the highest number of units with intensities between 900 and 1,200 mW/cm 2 . The output of all the units in service was satisfactory for curing conventional resin composites, and most units were capable of curing bulk-fill resin materials.

  19. Assessment of hospital daily cleaning practices using ATP bioluminescence in a developing country.

    PubMed

    Zambrano, Alejandra A; Jones, Alex; Otero, Paula; Ajenjo, Maria Cristina; Labarca, Jaime A

    2014-01-01

    Visual assessment of surfaces may not be enough to document the level of cleanliness in the hospital setting. It is necessary to introduce quantitative methods to document the results of this practice. To evaluate the efficacy of hospital terminal cleaning procedures, using an adenosine triphosphate (ATP) bioluminescence method in a teaching hospital. During 2008 we conducted an evaluation using ATP bioluminescence LIGHTNING MVP™ (Arquimed) of external and internal housekeeping service. After conducting an initial evaluation we implemented education of cleaning practices and finally we did a post intervention evaluation. Using chi-square method we compared prior versus after cleaning, quality of cleaning performed by external versus internal personnel, single versus double terminal cleaning procedures and prior versus after intervention. A finding of three RLU or less was considered a clean surface. We performed 198 evaluations in 33 patient units and nine OR. Internal personnel accomplished 25.37% of clean surfaces before and 80% after the education intervention (p=0.01). In contrast, external personnel obtained 68.8% before and 73.33% after intervention (p=0.3). This study suggests that visual assessment is not enough to ensure quality of the process and it is necessary to document the level of cleanliness by quantitative methods. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  20. Assessing the impact of a school-based latrine cleaning and handwashing program on pupil absence in Nyanza Province, Kenya: a cluster-randomized trial.

    PubMed

    Caruso, Bethany A; Freeman, Matthew C; Garn, Joshua V; Dreibelbis, Robert; Saboori, Shadi; Muga, Richard; Rheingans, Richard

    2014-10-01

    Improving school water, sanitation and hygiene (WASH) conditions reduces pupil absence and illness. However, these benefits may depend on the conditions of the latrines and availability of consumables. We sought to determine whether a low-cost, policy-relevant, environmental-level latrine cleaning intervention could improve latrine cleanliness, increase its use and reduce absenteeism. In a three-arm, cluster-randomized trial we assessed absence via periodical roll-call among 17 564 pupils in 60 schools that had previously received WASH improvements as part of the SWASH+ project. Latrine conditions and use were also assessed using structured observation. Latrine cleanliness increased significantly during the post-intervention period among schools receiving the latrine cleaning package compared to controls, as did handwashing with soap. We found no difference in latrine use and absence across arms. The additive impact of cleaning may not have been strong enough to impact absence above and beyond reductions attributable to the original WASH infrastructure improvements and basic hygiene education the schools previously received. Improving latrine conditions is important for the dignity and well-being of pupils, and investments and strategies are necessary to ensure that school toilets are clean and pupil-friendly. © 2014 John Wiley & Sons Ltd.

  1. Aluminum work function: Effect of oxidation, mechanical scraping and ion bombardment

    NASA Technical Reports Server (NTRS)

    Vinet, P.; Lemogne, T.; Montes, H.

    1985-01-01

    Surface studies have been performed on aluminum polycrystalline surfaces which have been mechanically scraped. Such studies were initiated in order to understand surface effects occurring in tribological processes which involve rubbing surfaces and the effects of adsorption of oxygen. To characterize the surfaces, the following three different experimental approaches have been used: (1) X.P.S. (X-ray photoelectron spectroscopy), in order to check the cleanliness of the surfaces and follow the adsorption and oxidation kinetics; (2) Analysis of the work function changes by following the energy spectra of secondary electrons emitted under low energy electron bombardment; and (3) Analysis of photoemission intensities under U.V. excitation. The reference state being chosen to be the surface cleaned by ion bombardment and exposures to oxygen atmospheres have been shown to lower the work function of clean polycrystalline aluminum by 1.2 eV. The oxygen pressure is found to affect only the kinetics of these experiments. Mechanical scraping has been shown to induce a decrease ( 0.3 eV) in the work function, which could sharply modify the kinetics of adsorption on the surface.

  2. Efficacy of sodium hypochlorite, ethylenediaminetetraacetic acid, citric acid and phosphoric acid in calcium hydroxide removal from the root canal: a microscopic cleanliness evaluation.

    PubMed

    da Silva, Juliana Melo; Silveira, Amanda; Santos, Elizandra; Prado, Laiìs; Pessoa, Oscar F

    2011-12-01

    Rooted molars were subjected to standardized canal instrumentation to a master apical file (MAF). The samples were dressed with Ca(OH)(2), and after 7 days, teeth were reopened and Ca(OH)(2) medication was removed by 1 of 4 different experimental procedures: 2.5% sodium hypochlorite (NaOCl) (n = 10); 17% EDTA-T (n = 10); 10% citric acid (n = 10); or 37% phosphoric acid (n = 10). This was followed by reinstrumentation with MAF plus 15 mL saline solution. The roots were prepared for scanning electron microscopic analysis of the cervical, middle, and apical thirds. Statistical analysis was performed with the Kruskal-Wallis test. EDTA-T and phosphoric acid gave the best results in the apical third, with significant statistical differences compared with other groups. NaOCl gave the worst results. Irrigation with 17% EDTA-T and 37% phosphoric acid is more effective than sodium hypochlorite and citric acid in the removal of calcium hydroxide from the apical third. Copyright © 2011 Mosby, Inc. All rights reserved.

  3. Satisfaction of patients suffering from type 2 diabetes and/or hypertension with care offered in family medicine clinics in Mexico.

    PubMed

    Doubova, Svetlana Vladislavovna; Pérez-Cuevas, Ricardo; Zepeda-Arias, Maribel; Flores-Hernández, Sergio

    2009-01-01

    To evaluate the satisfaction and the factors related to dissatisfaction in patients suffering from type 2 diabetes and/or hypertension with care offered in family medicine clinics. A secondary data analysis was conducted. Main outcome measures were two indices of satisfaction: family doctor-patient relationship (FDPR) and clinic organizational arrangements (OA). Approximately half of patients (n=1 323) were satisfied with care. In the FDPR index the items 'kindness of the family doctor' (FD) scored high, while the lowest score was for the items: 'the FD allows the patient to give an opinion about his/her treatment,' 'the patient understands the information' and 'the FD spends enough time on the consultation.' As for satisfaction with OA, the items 'cleanliness of the clinic' and 'ease of administrative procedures' obtained the lowest scores. In the logistic regression analysis the covariate 'negative self-rated health' and 'type of institution' were associated with dissatisfaction. There are aspects of the FDPR and OA that reveal dissatisfaction of patients with chronic conditions.

  4. Evaluation of Dermatology Practice Online Reviews: Lessons From Qualitative Analysis.

    PubMed

    Smith, Robert J; Lipoff, Jules B

    2016-02-01

    Patient satisfaction is an increasingly important component of health care quality measures. Online reviews of physicians represent a promising platform for capturing patient perspectives of care. To identify qualitative themes associated with patient reviews of dermatologic care on consumer reporting websites. A qualitative analysis was conducted of patient-generated reviews of dermatology practices on 2 consumer review platforms. Yelp is an online consumer portal for users to review their experience with local businesses; ZocDoc is an online patient-scheduling portal that provides opportunity for patients to write reviews of physician practices. A total of 518 reviews from 45 dermatology practices on Yelp and 4921 reviews from 45 dermatology providers on ZocDoc were collected from 3 geographically diverse cities: Philadelphia, Pennsylvania; Houston, Texas; and Seattle, Washington. The study was conducted from January 15 to July 15, 2015. Reviews were separated into high-scoring and low-scoring groups. An inductive qualitative method was used to code and identify key themes associated with positive and negative patient experiences. Analysis was completed upon reaching thematic saturation. Reported as mean (95% CI), the overall Yelp score for the 45 selected practices was 3.46 of 5 stars (3.17-3.75) and overall ZocDoc score for the 45 selected practices was 4.72 of 5 stars (4.47-4.80). The proportion of individual reviews giving a score of 5.0 was significantly higher on ZocDoc (3986 [81.0%]) than on Yelp (229 [44.2%]) (P < .001). Qualitative themes centered on characteristics of the physician and the practice. Themes that emerged from the high-scoring and low-scoring reviews were similar in content but opposite in valence. Physician-specific themes included temperament, knowledge and competency, physical examination, communication abilities, and mindfulness of cost. Practice-specific themes included scheduling, staff temperament, office cleanliness, waiting room, and insurance. Patients appreciated physicians who are kind, respectful, and thorough with the physical examination; empathetic about the emotional difficulty of skin disease; and cognizant of cost. Negative experiences were frequently affected by considerations outside of the physician-patient interaction, such as curt interactions with staff, difficulty with scheduling, practice cleanliness, and insurance problems. Patients reported relying on consumer websites to identify dermatology providers. Online consumer review websites are designed to facilitate instantaneous and public communication among patients. These platforms provide elaborate and timely data for dermatologists to garner insight into their patients' experiences. The themes identified in this study are consistent with past satisfaction studies and may aid dermatologists in optimizing the patient care experience.

  5. TOP 08-2-111B Chemical, Biological, and Radiological (CBR) Contamination Survivability, Small Items of Equipment

    DTIC Science & Technology

    2016-03-16

    e.g., mud, grease, and other). j. Pretest (baseline) and posttest (30 days after the first contamination and/or other defined long-term time...item surface condition (pretest and posttest ), materials of construction, paint type, and surface cleanliness (e.g., mud, grease, decontamination...penetrate. h. Pretest and posttest ME functional performance characteristics used as the measure of the test item’s mission performance before

  6. Polyester Resin Hazards

    PubMed Central

    Bourne, L. B.; Milner, F. J. M.

    1963-01-01

    Polyester resins are being increasingly used in industry. These resins require the addition of catalysts and accelerators. The handling of polyester resin system materials may give rise to skin irritations, allergic reactions, and burns. The burns are probably due to styrene and organic peroxides. Atmospheric pollution from styrene and explosion and fire risks from organic peroxides must be prevented. Where dimethylaniline is used scrupulous cleanliness and no-touch technique must be enforced. Handling precautions are suggested. Images PMID:14014495

  7. In orbit sun calibration performance of Landsat-2

    NASA Technical Reports Server (NTRS)

    Horan, J. J.; Schwartz, D. S.; Love, J. D.

    1975-01-01

    Sun calibration data from Landsat-2 are presented and compared with those from Landsat-1 (ERTS-1). The data support the hypothesis that organic contamination caused the poor performance of the Landsat-1 sun calibration mirror, since extra cleanliness precautions were taken with the Landsat-2 mirror. These precautions are described; of particular importance was the aluminum foil covering kept close to the reflective surfaces of the second mirror during the prelaunch period.

  8. NASA Workmanship Hot Topics: Water Soluble Flux and ESD Charge Device Model

    NASA Technical Reports Server (NTRS)

    Plante, Jeannette F.

    2009-01-01

    This slide presentation reviews two topics of interest to NASA Workmanship: (1) Water Soluble Flux (WSF) and Electrostatic Discharge (ESD) safety. In the first topic, WSF, the presentation reviews voiding and the importance of cleanliness in using WSF for welding and soldering operations. The second topic reviews the NASA-HDBK-8739.21 for Human Body Model, and Machine Model safety methods, and challenges associated with the Charged Device Model (CDM)

  9. Grazing-Angle Fourier Transform Infrared Spectroscopy for Surface Cleanliness Verification

    DTIC Science & Technology

    2003-03-01

    coating. 34 North Island personnel were also interested in using the portable FTIR instrument to detect a trivalent chromium conversion coating on... trivalent chromium coating on aluminum panels. 35 Following the successful field-test at NADEP North Island in December 2000, a second demonstration of...contaminated, the panels were allowed to dry under a fume hood to evaporate the solvent. They were then placed in a desiccator for final drying. This

  10. Field Evaluation of Particle Counter Technology for Aviation Fuel Contamination Detection - Fort Rucker

    DTIC Science & Technology

    2013-06-20

    Automatic Particle Counter, cleanliness, free water, Diesel 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT none 18. NUMBER OF PAGES...Governmental transfer receipts and 1.0 mg/L on issue to aircraft, or up to 10 mg/L for product used as a diesel product for ground use (1). Free...industry. The International Organization for Standardization (ISO) has published several methods and test procedures for the calibration and use of

  11. PubMed Central

    Ceriale, E.; Messina, G.; Lenzi, D.; Manzi, P.

    2017-01-01

    Summary Introduction. Contamination of hospital surfaces plays an important role in the transmission of several healthcare-associated microorganisms, therefore methods for evaluating hospital surfaces' cleaning gain particular importance. Among these, there are visual inspection, quantitative microbiology, fluorescent markers and adenosine triphosphate (ATP) bioluminescence. The latter seems to provide interesting features, detecting the presence of ATP on surface (as Relative Light Units, RLU), a proxy of organic matter and microbial contamination. Several studies have investigated the effectiveness of this technology; with this research, we aim to summarize the most significant results. Methods. A systematic review was conducted. The keywords (namely, "ATP", "bioluminescence", "hospital" and "surfaces") were searched in PubMed/MEDLINE and Scopus databases, in order to find relevant data, from January 2000 to October 2014. After the selection, we globally considered 27 articles. Results. Most of the studies were conducted in United Kingdom and in USA. Different threshold RLU benchmark values were identified by analyzed studies. Fourteen of these researches compared the ATP bioluminescence with microbiological methods, 11 identified a significant correlation between the two methods, although poor or not complete for 5. Discussion. ATP bioluminescence is not a standardized methodology: each tool has different benchmark values, not always clearly defined. At the moment, we can say that the technique could be used to assess, in real time, hospital surfaces where cleanliness is required, but not sterility. PMID:28900359

  12. Implementation of 5S Method for Ergonomic Laboratory

    NASA Astrophysics Data System (ADS)

    Dila Sari, Amarria; Ilma Rahmillah, Fety; Prabowo Aji, Bagus

    2017-06-01

    This article discusses 5S implementation in Work System Design and Ergonomic Laboratory, Department of Industrial Engineering, Islamic University of Indonesia. There are some problems related to equipment settings for activity involving students such as files which is accumulated over the previous year practicum, as well as the movement of waste in the form of time due to the placement of goods that do not fit. Therefore, this study aims to apply the 5S method in DSK & E laboratory to facilitate the work processes and reduce waste. The project is performed by laboratory management using 5S methods in response to continuous improvement (Kaizen). Moreover, some strategy and suggestions are promoted to impose 5S system within the laboratory. As a result, the tidiness and cleanliness can be achieved that lead to the great performance of laboratory users. Score assessment before implementing 5S DSKE laboratory is at 64 (2.56) while the score after implementation is 32 (1.28) and shows an improvement of 50%. This has implications for better use in the laboratory area, save time when looking for tools and materials due to its location and good visual control, as well as improving the culture and spirit of ‘5S’ on staff regarding better working environment

  13. Electrosurgical Smoke: Ultrafine Particle Measurements and Work Environment Quality in Different Operating Theatres

    PubMed Central

    Romano, Francesco; Gustén, Jan; De Antonellis, Stefano; Joppolo, Cesare M.

    2017-01-01

    Air cleanliness in operating theatres (OTs) is an important factor for preserving the health of both the patient and the medical staff. Particle contamination in OTs depends mainly on the surgery process, ventilation principle, personnel clothing systems and working routines. In many open surgical operations, electrosurgical tools (ESTs) are used for tissue cauterization. ESTs generate a significant airborne contamination, as surgical smoke. Surgical smoke is a work environment quality problem. Ordinary surgical masks and OT ventilation systems are inadequate to control this problem. This research work is based on numerous monitoring campaigns of ultrafine particle concentrations in OTs, equipped with upward displacement ventilation or with a downward unidirectional airflow system. Measurements performed during ten real surgeries highlight that the use of ESTs generates a quite sharp and relevant increase of particle concentration in the surgical area as well within the entire OT area. The measured contamination level in the OTs are linked to surgical operation, ventilation principle, and ESTs used. A better knowledge of airborne contamination is crucial for limiting the personnel’s exposure to surgical smoke. Research results highlight that downward unidirectional OTs can give better conditions for adequate ventilation and contaminant removal performances than OTs equipped with upward displacement ventilation systems. PMID:28146089

  14. Optimizing surface finishing processes through the use of novel solvents and systems

    NASA Astrophysics Data System (ADS)

    Quillen, M.; Holbrook, P.; Moore, J.

    2007-03-01

    As the semiconductor industry continues to implement the ITRS (International Technology Roadmap for Semiconductors) node targets that go beyond 45nm [1], the need for improved cleanliness between repeated process steps continues to grow. Wafer cleaning challenges cover many applications such as Cu/low-K integration, where trade-offs must be made between dielectric damage and residue by plasma etching and CMP or moisture uptake by aqueous cleaning products. [2-5] Some surface sensitive processes use the Marangoni tool design [6] where a conventional solvent such as IPA (isopropanol), combines with water to provide improved physical properties such as reduced contact angle and surface tension. This paper introduces the use of alternative solvents and their mixtures compared to pure IPA in removing ionics, moisture, and particles using immersion bench-chemistry models of various processes. A novel Eastman proprietary solvent, Eastman methyl acetate is observed to provide improvement in ionic, moisture capture, and particle removal, as compared to conventional IPA. [7] These benefits may be improved relative to pure IPA, simply by the addition of various additives. Some physical properties of the mixtures were found to be relatively unchanged even as measured performance improved. This report presents our attempts to cite and optimize these benefits through the use of laboratory models.

  15. Inclusion evolution in molten and solidifying steel

    NASA Astrophysics Data System (ADS)

    Wang, Yan

    Cleanliness, with respect to impurities and nonmetallic inclusions in the melt, is an important issue in steel production. The commercial interest in controlling steel cleanliness has been growing rapidly, because clean steel exhibits a highly attractive combination of corrosion resistance, good formability, pleasing appearance, and a wide range of strength levels. In order to satisfy the requirements for the degree of cleanliness in steel, controlling the size distribution, chemistry and shape of inclusions are of great importance in the steelmaking process. A knowledge of the formation of nonmetallic inclusions and their chemical and morphological evolution during the steelmaking and casting process is necessary in order to minimize the inclusion size and also try to promote potentially beneficial properties of inclusions, such as grain-refining. In this research, the evolution of inclusions in molten and solidifying steels was investigated through in-situ observations using a high temperature Confocal Scanning Laser Microscope (CSLM). The study focused on solid Al2O3 and liquid Al 2O3-CaO inclusions on low carbon steel melt surfaces. Firstly, the agglomeration and clustering of inclusions on steel surfaces were quantified and compared to predictions according to capillary depression driven attraction forces. A strong agglomeration was observed between the solid Al2O33 particle pairs. However, the liquid Al 2O3-CaO inclusions were not prone to agglomeration due to their lens-like morphology, which causes the absence of capillary force. Secondly, the pushing vs. engulfment and entrapment of both liquid Al 2O3-CaO and solid Al2O3 inclusions by advancing planar and cellular delta-ferrite solidification fronts was studied and compared to model predictions based on the force balances acting on the inclusions at the solid/melt interface. The critical velocity, above which the inclusions get engulfed, was observed to be slower at the cellular front than at the planar interface for liquid Al2O3-CaO inclusions. This indicates that these inclusions tend to more easily get engulfed at inter-cellular boundaries. However, there was no appreciable difference observed about the critical velocity for the large solid Al2O 3 inclusion clusters at the cellular boundary with that at the planar interface. The pushed liquid Al2O3-CaO inclusions were subject to a chemical and morphological change during solidification. (Abstract shortened by UMI.)

  16. Assessment of antiretroviral treatment (ART) care service provision in Tigray Region health centers, North Ethiopia.

    PubMed

    Tessema, Shewaye Belay; Adane, Mesafint Molla

    2015-09-10

    Client satisfaction is a vital component and main concern intertwined with strategic decisions in service provisions. To improve efficiency of services, eliciting the opinion of users about the available services and identifying factors associated with dissatisfaction is very critical. Thus, the main objective of this study was to assess the perceived levels of clients' satisfaction with health services at ART clinic level in health centres of Tigray Region in Ethiopia. Cross sectional study was conducted from May to June 2013 in Tigray Region ART clinics. A total of 714 ART care user were included in the study using both purposive and probability sampling technique. Data was collected by using structured questionnaire and the collected data was analysed using Statistical Package for the Social Sciences (SPSS) version 16.0. Crude and Adjusted logistic regression analyses were carried out to identify the associated factors underlying perceived levels of clients' overall satisfaction. Finally, the results were presented with table as well as odds ratio (OR) and 95% confidence interval (CI). A total of 714 study participants were enrolled in this study. An overall satisfaction level of 89.6% was reported by ART care service users. Higher scores of satisfaction of services provisions were reported for courtesy and respect (95.80%) followed by privacy (93.28%). On the other hand, respondents' dissatisfaction was rated 35.32% for toilet cleanliness followed by 26.19% for availability of additional drugs. As for overall satisfaction and associated factors, adjusted logistic regression analyses showed that marital status [AOR = 2.01 (95% CI: 1.11, 3.60)], educational status [AOR = 3.13 (95% CI: 1.15, 8.53)], travel distance to reach health centre [AOR = 3.59 (95% CI: 1.23, 10.50)], toilet cleanliness [AOR = 2.22 (95% CI :1.62, 6.32)], and ART drug availability [AOR = 2.60 (95% CI :1.18, 6.52)] were found to have influence on overall ART service satisfaction status. This study revealed high level of client satisfaction rate and were associated with preventable and modifiable factors such as marital status, educational status, travel distance to reach health centre, toilet cleanliness and ART drug availability. Therefore, countermeasures such as increasing access to ART service, availing clean toilet and ART drugs may further increase client satisfaction level in the region.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooke, Steven J.; Nguyen, Vivian M.; Murchie, Karen J.

    The advent and widespread adoption of electronic tags (including biotelemetry and biologging devices) for tracking animals has provided unprecedented information on the biology, management, and conservation of fish in the world’s oceans and inland waters. However, use of these tools is not without controversy. Even when scientific and management objectives may best be achieved using electronic tags, it is increasingly important to further consider other factors such as the welfare of tagged animals (i.e., the role of training and science-based surgical guidelines, anesthetic use, inability to maintain sterile conditions in field environments), the ethics of tagging threatened species vs. usingmore » surrogates, stakeholder perspectives on tagging (including aboriginals), as well as use of data emanating from such studies (e.g., by fishers to facilitate exploitation). Failure to do so will have the potential to create conflict and undermine scientific, management and public confidence in the use of this powerful tool. Indeed, there are already a number of examples of where tracking studies using electronic tags have been halted based on concerns raised by researchers, authorities, or stakeholders. Here we present a candid evaluation of several factors that should be considered when determining when to tag or not to tag fish with electronic devices. It is not our objective to judge the merit of previous studies. Rather, we hope to stimulate debate and discussion regarding the use of electronic tags to study fish. Relatedly, there is a need for more research to address these questions (e.g., what level of cleanliness is needed when conducting surgeries, what type of training should be required for fish surgery) including human dimensions studies to understand perspectives of different actors including society as a whole with respect to tagging and tracking studies.« less

  18. Field Evaluation of Particle Counter Technology for Aviation Fuel Contamination Detection - Fort Campbell

    DTIC Science & Technology

    2013-06-06

    Counter, cleanliness, free water, Diesel 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT none 18. NUMBER OF PAGES 31 19a. NAME OF...L for Intra-Governmental transfer receipts and 1.0 mg/L on issue to aircraft, or up to 10 mg/L for product used as a diesel product for ground use...hydraulic fluid industry. The International Organization for Standardization (ISO) has published several methods and test procedures for the calibration and

  19. Vestibular Function Measurement Devices

    PubMed Central

    Miles, Richard D.; Zapala, David A.

    2015-01-01

    Vestibular function laboratories utilize a multitude of diagnostic instruments to evaluate a dizzy patient. Caloric irrigators, oculomotor stimuli, and rotational chairs produce a stimulus whose accuracy is required for the patient response to be accurate. Careful attention to everything from cleanliness of equipment to threshold adjustments determine on a daily basis if patient data are going to be correct and useful. Instrumentation specifications that change with time such as speed and temperature must periodically be checked using calibrated instruments. PMID:27516710

  20. The Effects of Steel Profile and Cleanliness on Coating Performance

    DTIC Science & Technology

    1986-01-01

    describes the results of this extensive 5-year study. •-0 BACKGROUND Abrasive blasting of steel is generally the preferred method of preparing steel...environment (SSPC used procedure 6061 of Federal Test Method Standard No. 141), and two specimens after 15 and 57 months of exposure at Kwajalein. In the...UNIVERSITY OF XASHI.%GTON Dept of Crsil Engr (Dr Mattock). Seattle WA. Librars. Seattle. WA UNIVERSITY OF WISCONSIN Great Lakes Studtes Citr. Mtis~ wacee

  1. Cleaning Hospital Room Surfaces to Prevent Health Care-Associated Infections: A Technical Brief.

    PubMed

    Han, Jennifer H; Sullivan, Nancy; Leas, Brian F; Pegues, David A; Kaczmarek, Janice L; Umscheid, Craig A

    2015-10-20

    The cleaning of hard surfaces in hospital rooms is critical for reducing health care-associated infections. This review describes the evidence examining current methods of cleaning, disinfecting, and monitoring cleanliness of patient rooms, as well as contextual factors that may affect implementation and effectiveness. Key informants were interviewed, and a systematic search for publications since 1990 was done with the use of several bibliographic and gray literature resources. Studies examining surface contamination, colonization, or infection with Clostridium difficile, methicillin-resistant Staphylococcus aureus, or vancomycin-resistant enterococci were included. Eighty studies were identified-76 primary studies and 4 systematic reviews. Forty-nine studies examined cleaning methods, 14 evaluated monitoring strategies, and 17 addressed challenges or facilitators to implementation. Only 5 studies were randomized, controlled trials, and surface contamination was the most commonly assessed outcome. Comparative effectiveness studies of disinfecting methods and monitoring strategies were uncommon. Future research should evaluate and compare newly emerging strategies, such as self-disinfecting coatings for disinfecting and adenosine triphosphate and ultraviolet/fluorescent surface markers for monitoring. Studies should also assess patient-centered outcomes, such as infection, when possible. Other challenges include identifying high-touch surfaces that confer the greatest risk for pathogen transmission; developing standard thresholds for defining cleanliness; and using methods to adjust for confounders, such as hand hygiene, when examining the effect of disinfecting methods.

  2. The impact of gender and physical environment on the handwashing behaviour of university students in Ghana.

    PubMed

    Mariwah, Simon; Hampshire, Kate; Kasim, Adetayo

    2012-04-01

    To establish levels of handwashing after defecation among students at the University of Cape Coast in Ghana, and to test hypotheses that gender and washroom environment affect handwashing behaviour. Data on students' handwashing behaviour after defecation were collected by structured observations in washrooms. Eight hundred and six observations were made (360 female students and 446 males) in 56 washrooms over 496 observation periods. Observers recorded gender, duration of handwashing, use of soap, and physical characteristics of the washroom (cleanliness, availability of soap, tap flow and presence of handwashing posters). Fewer than half the students observed washed their hands or bathed after defecation. Of these, only two-thirds washed both hands and a minority (20%) used soap; only 16 students (all men) washed their hands for the recommended 15 s or longer. Female students were more likely to wash their hands at all, and were more likely to wash both hands, than males. Cleanliness of the washroom was strongly associated with improved handwashing behaviour for both women and men, as was tap flow quality for female students. Handwashing behaviour is generally poor among UCC students, mirroring results from North American Universities. The findings underline the plasticity of handwashing behaviour among this population, and highlight the need for ensuring that the physical environment in washrooms on university campuses is conducive to handwashing. © 2012 Blackwell Publishing Ltd.

  3. Implementing planetary protection on the Atlas V fairing and ground systems used to launch the Mars Science Laboratory.

    PubMed

    Benardini, James N; La Duc, Myron T; Ballou, David; Koukol, Robert

    2014-01-01

    On November 26, 2011, the Mars Science Laboratory (MSL) launched from Florida's Cape Canaveral Air Force Station aboard an Atlas V 541 rocket, taking its first step toward exploring the past habitability of Mars' Gale Crater. Because microbial contamination could profoundly impact the integrity of the mission, and compliance with international treaty was a necessity, planetary protection measures were implemented on all MSL hardware to verify that bioburden levels complied with NASA regulations. The cleanliness of the Atlas V payload fairing (PLF) and associated ground support systems used to launch MSL were also evaluated. By applying proper recontamination countermeasures early and often in the encapsulation process, the PLF was kept extremely clean and was shown to pose little threat of recontaminating the enclosed MSL flight system upon launch. Contrary to prelaunch estimates that assumed that the interior PLF spore burden ranged from 500 to 1000 spores/m², the interior surfaces of the Atlas V PLF were extremely clean, housing a mere 4.65 spores/m². Reported here are the practices and results of the campaign to implement and verify planetary protection measures on the Atlas V launch vehicle and associated ground support systems used to launch MSL. All these facilities and systems were very well kept and exceeded the levels of cleanliness and rigor required in launching the MSL payload.

  4. Properties Data for Adhesion and Surface Chemistry of Aluminum: Sapphire-Aluminum, Single-Crystal Couple

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa; Pohlchuck, Bobby; Whitle, Neville C.; Hector, Louis G., Jr.; Adams, Jim

    1998-01-01

    An investigation was conducted to examine the adhesion and surface chemistry of single-crystal aluminum in contact with single-crystal sapphire (alumina). Pull-off force (adhesion) measurements were conducted under loads of 0. I to I mN in a vacuum of 10(exp -1) to 10(exp -9) Pa (approx. 10(exp -10) to 10(exp -11) torr) at room temperature. An Auger electron spectroscopy analyzer incorporated directly into an adhesion-measuring vacuum system was primarily used to define the chemical nature of the surfaces before and after adhesion measurements. The surfaces were cleaned by argon ion sputtering. With a clean aluminum-clean -sapphire couple the mean value and standard deviation of pull-off forces required to separate the surfaces were 3015 and 298 micro-N, respectively. With a contaminated aluminum-clean sapphire couple these values were 231 and 241 micro-N. The presence of a contaminant film on the aluminum surface reduced adhesion by a factor of 13. Therefore, surfaces cleanliness, particularly aluminum cleanliness, played an important role in the adhesion of the aluminum-sapphire couples. Pressures on the order of 10(exp -8) to 10(exp -9) Pa (approx. 10(exp -10) to 10(exp -11) torr) maintained a clean aluminum surface for only a short time (less then 1 hr) but maintained a clean sapphire surface, once it was achieved, for a much longer time.

  5. Cleaning Hospital Room Surfaces to Prevent Health Care–Associated Infections

    PubMed Central

    Han, Jennifer H.; Sullivan, Nancy; Leas, Brian F.; Pegues, David A.; Kaczmarek, Janice L.; Umscheid, Craig A.

    2015-01-01

    The cleaning of hard surfaces in hospital rooms is critical for reducing health care–associated infections. This review describes the evidence examining current methods of cleaning, disinfecting, and monitoring cleanliness of patient rooms, as well as contextual factors that may affect implementation and effectiveness. Key informants were interviewed, and a systematic search for publications since 1990 was done with the use of several bibliographic and gray literature resources. Studies examining surface contamination, colonization, or infection with Clostridium difficile, methicillin-resistant Staphylococcus aureus, or vancomycinresistant enterococci were included. Eighty studies were identified—76 primary studies and 4 systematic reviews. Forty-nine studies examined cleaning methods, 14 evaluated monitoring strategies, and 17 addressed challenges or facilitators to implementation. Only 5 studies were randomized, controlled trials, and surface contamination was the most commonly assessed outcome. Comparative effectiveness studies of disinfecting methods and monitoring strategies were uncommon. Future research should evaluate and compare newly emerging strategies, such as self-disinfecting coatings for disinfecting and adenosine triphosphate and ultraviolet/fluorescent surface markers for monitoring. Studies should also assess patient-centered outcomes, such as infection, when possible. Other challenges include identifying high-touch surfaces that confer the greatest risk for pathogen transmission; developing standard thresholds for defining cleanliness; and using methods to adjust for confounders, such as hand hygiene, when examining the effect of disinfecting methods. PMID:26258903

  6. Contamination control engineering design guidelines for the aerospace community

    NASA Technical Reports Server (NTRS)

    Tribble, A. C. (Principal Investigator); Boyadjian, B.; Davis, J.; Haffner, J.; McCullough, E.

    1996-01-01

    Thermal control surfaces, solar arrays, and optical devices may be adversely affected by a small quantity of molecular and/or particulate contamination. What is rarely discussed is how one: (1) quantifies the level of contamination that must be maintained in order for the system to function properly, and (2) enforces contamination control to ensure compliance with requirements. This document is designed to address these specific issues and is intended to serve as a handbook on contamination control for the reader, illustrating process and methodology while providing direction to more detailed references when needed. The effects of molecular contamination on reflecting and transmitting surfaces are examined and quantified in accordance with MIL STD 1246C. The generation, transportation, and deposition of molecular contamination is reviewed and specific examples are worked to illustrate the process a design engineer can use to estimate end of life cleanliness levels required by solar arrays, thermal control surfaces, and optical surfaces. A similar process is used to describe the effect of particulate contamination as related to percent area coverage (PAC) and bi-directional reflectance distribution function (BRDF). Relationships between PAC and surface cleanliness, which include the effects of submicron sized particles, are developed and BRDF is related to specific sensor design parameters such as Point Source Transmittance (PST). The pros and cons of various methods of preventing, monitoring, and cleaning surfaces are examined and discussed.

  7. A "clean cigarette" for a clean nation: a case study of Salem Pianissimo in Japan

    PubMed Central

    Assunta, M; Chapman, S

    2004-01-01

    Objective: To illustrate, through internal industry documents, how RJ Reynolds exploited the concerns of the Japanese society about cleanliness to market the concept of cleaner, implicitly healthier cigarettes in Japan. Design: Systematic keyword and opportunistic website searches of formerly private internal industry documents. Results: Industry documents show that RJ Reynolds developed marketing plans based upon their cultural assumptions of Japanese people as fastidious about hygiene and manners, and with relatively high penchants to try new products. RJ Reynolds found there was also a growing concern for health, the environment, and smokers were conscious about annoying others. Deodorised consumer products were one of Japan's biggest trends. These characteristics presented RJ Reynolds with a profitable formula for marketing Salem Pianissimo, a clean cigarette with less smell and smoke. Salem Pianissimo, a 100 mm cigarette claiming to contain 1 mg tar and 0.1 mg nicotine, targeted women since menthol cigarettes were popular among 18–24 year old female smokers, although Japan's law prohibited those below 20 years to smoke and the tobacco industry had a voluntary code disallowing advertising to women and youth. Conclusion: RJ Reynolds successfully launched its clean cigarette, Salem Pianissimo, in Japan aiming to exploit perceived cultural characteristics such as a penchant for cleanliness, an eagerness to try new products, and social harmony. PMID:15564222

  8. Assessing the impact of a school-based latrine cleaning and handwashing program on pupil absence in Nyanza Province, Kenya: A cluster-randomized trial

    PubMed Central

    Caruso, Bethany A.; Freeman, Matthew C.; Garn, Joshua V.; Dreibelbis, Robert; Saboori, Shadi; Muga, Richard; Rheingans, Richard

    2016-01-01

    Improving school water, sanitation and hygiene (WASH) conditions has been shown to be effective in reducing pupil absence and illness. However, the benefit of sanitation and hygiene promotion improvements at school may depend on the conditions of the latrines and availability of consumables. We employed a three-arm, cluster-randomized trial to determine if a low-cost, policy-relevant, environmental-level latrine cleaning intervention could a) improve latrine cleanliness, b) increase latrine use, and c) reduce absenteeism. We assessed absence via periodical roll-call among 17,564 pupils in 60 schools that previously received WASH Improvements as part of the SWASH+ project. Latrine conditions and use were also assessed using structured observation. Latrine cleanliness increased significantly during the post-intervention period among schools receiving the latrine-cleaning package compared to controls. Handwashing with soap increased as well in intervention schools relative to controls. We found no difference in latrine use and absence across arms. The additive impact of cleaning may not have been strong enough to impact absence above and beyond reductions attributable to the original WASH infrastructure improvements and basic hygiene education the schools previously received. Improving latrine conditions is important for the dignity and well being of pupils, and investments and strategies are necessary to ensure school sanitation environments are clean and pupil-friendly. PMID:25055716

  9. Perception of color emotions for single colors in red-green defective observers.

    PubMed

    Sato, Keiko; Inoue, Takaaki

    2016-01-01

    It is estimated that inherited red-green color deficiency, which involves both the protan and deutan deficiency types, is common in men. For red-green defective observers, some reddish colors appear desaturated and brownish, unlike those seen by normal observers. Despite its prevalence, few studies have investigated the effects that red-green color deficiency has on the psychological properties of colors (color emotions). The current study investigated the influence of red-green color deficiency on the following six color emotions: cleanliness, freshness, hardness, preference, warmth, and weight. Specifically, this study aimed to: (1) reveal differences between normal and red-green defective observers in rating patterns of six color emotions; (2) examine differences in color emotions related to the three cardinal channels in human color vision; and (3) explore relationships between color emotions and color naming behavior. Thirteen men and 10 women with normal vision and 13 men who were red-green defective performed both a color naming task and an emotion rating task with 32 colors from the Berkeley Color Project (BCP). Results revealed noticeable differences in the cleanliness and hardness ratings between the normal vision observers, particularly in women, and red-green defective observers, which appeared mainly for colors in the orange to cyan range, and in the preference and warmth ratings for colors with cyan and purple hues. Similarly, naming errors also mainly occurred in the cyan colors. A regression analysis that included the three cone-contrasts (i.e., red-green, blue-yellow, and luminance) as predictors significantly accounted for variability in color emotion ratings for the red-green defective observers as much as the normal individuals. Expressly, for warmth ratings, the weight of the red-green opponent channel was significantly lower in color defective observers than in normal participants. In addition, the analyses for individual warmth ratings in the red-green defective group revealed that luminance cone-contrast was a significant predictor in most red-green-defective individuals. Together, these results suggest that red-green defective observers tend to rely on the blue-yellow channel and luminance to compensate for the weak sensitivity of long- and medium-wavelength (L-M) cone-contrasts, when rating color warmth.

  10. Perception of color emotions for single colors in red-green defective observers

    PubMed Central

    Inoue, Takaaki

    2016-01-01

    It is estimated that inherited red-green color deficiency, which involves both the protan and deutan deficiency types, is common in men. For red-green defective observers, some reddish colors appear desaturated and brownish, unlike those seen by normal observers. Despite its prevalence, few studies have investigated the effects that red-green color deficiency has on the psychological properties of colors (color emotions). The current study investigated the influence of red-green color deficiency on the following six color emotions: cleanliness, freshness, hardness, preference, warmth, and weight. Specifically, this study aimed to: (1) reveal differences between normal and red-green defective observers in rating patterns of six color emotions; (2) examine differences in color emotions related to the three cardinal channels in human color vision; and (3) explore relationships between color emotions and color naming behavior. Thirteen men and 10 women with normal vision and 13 men who were red-green defective performed both a color naming task and an emotion rating task with 32 colors from the Berkeley Color Project (BCP). Results revealed noticeable differences in the cleanliness and hardness ratings between the normal vision observers, particularly in women, and red-green defective observers, which appeared mainly for colors in the orange to cyan range, and in the preference and warmth ratings for colors with cyan and purple hues. Similarly, naming errors also mainly occurred in the cyan colors. A regression analysis that included the three cone-contrasts (i.e., red-green, blue-yellow, and luminance) as predictors significantly accounted for variability in color emotion ratings for the red-green defective observers as much as the normal individuals. Expressly, for warmth ratings, the weight of the red-green opponent channel was significantly lower in color defective observers than in normal participants. In addition, the analyses for individual warmth ratings in the red-green defective group revealed that luminance cone-contrast was a significant predictor in most red-green-defective individuals. Together, these results suggest that red-green defective observers tend to rely on the blue-yellow channel and luminance to compensate for the weak sensitivity of long- and medium-wavelength (L-M) cone-contrasts, when rating color warmth. PMID:27957394

  11. Applications of Laser-Induced Breakdown Spectroscopy (LIBS) in Molten Metal Processing

    NASA Astrophysics Data System (ADS)

    Hudson, Shaymus W.; Craparo, Joseph; De Saro, Robert; Apelian, Diran

    2017-10-01

    In order for metals to meet the demand for critical applications in the automotive, aerospace, and defense industries, tight control over the composition and cleanliness of the metal must be achieved. The use of laser-induced breakdown spectroscopy (LIBS) for applications in metal processing has generated significant interest for its ability to perform quick analyses in situ. The fundamentals of LIBS, current techniques for deployment on molten metal, demonstrated capabilities, and possible avenues for development are reviewed and discussed.

  12. Wafer-to-wafer bonding of nonplanarized MEMS surfaces using solder

    NASA Astrophysics Data System (ADS)

    Sparks, D.; Queen, G.; Weston, R.; Woodward, G.; Putty, M.; Jordan, L.; Zarabadi, S.; Jayakar, K.

    2001-11-01

    The fabrication and reliability of a solder wafer-to-wafer bonding process is discussed. Using a solder reflow process allows vacuum packaging to be accomplished with unplanarized complementary metal-oxide semiconductor (CMOS) surface topography. This capability enables standard CMOS processes, and integrated microelectromechanical systems devices to be packaged at the chip-level. Alloy variations give this process the ability to bond at lower temperatures than most alternatives. Factors affecting hermeticity, shorts, Q values, shifting cavity pressure, wafer saw cleanliness and corrosion resistance will be covered.

  13. GSFC Space Simulation Laboratory Contamination Philosophy: Efficient Space Simulation Chamber Cleaning Techniques

    NASA Technical Reports Server (NTRS)

    Roman, Juan A.; Stitt, George F.; Roman, Felix R.

    1997-01-01

    This paper will provide a general overview of the molecular contamination philosophy of the Space Simulation Test Engineering Section and how the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) space simulation laboratory controls and maintains the cleanliness of all its facilities, thereby, minimizing down time between tests. It will also briefly cover the proper selection and safety precautions needed when using some chemical solvents for wiping, washing, or spraying thermal shrouds when molecular contaminants increase to unacceptable background levels.

  14. Optimizing Health Care Environmental Hygiene.

    PubMed

    Carling, Philip C

    2016-09-01

    This article presents a review and perspectives on aspects of optimizing health care environmental hygiene. The topics covered include the epidemiology of environmental surface contamination, a discussion of cleaning health care patient area surfaces, an overview of disinfecting health care surfaces, an overview of challenges in monitoring cleaning versus cleanliness, a description of an integrated approach to environmental hygiene and hand hygiene as interrelated disciplines, and an overview of the research opportunities and challenges related to health care environmental hygiene. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Evaluation of Bauer K-20 Diesel Drive High Pressure Breathing Air Compressor

    DTIC Science & Technology

    1993-12-01

    was to: A. Determine if the compressor and Purification System provides compressed air at the required pressures, flow rates, quality and cleanliness... compressed air return from the air storage flasks to the compressor during unit shut down. All four stages of the compressor are protected by safety...1993. 6. Naval Ships Technical Manual, S9086-SY-STM-0O0, Chapeter 551 1st Rev. I November 1987. Compressed Air Plants and Systems, para 551-4.2.21. 7

  16. Cleaning process for EUV optical substrates

    DOEpatents

    Weber, Frank J.; Spiller, Eberhard A.

    1999-01-01

    A cleaning process for surfaces with very demanding cleanliness requirements, such as extreme-ultraviolet (EUV) optical substrates. Proper cleaning of optical substrates prior to applying reflective coatings thereon is very critical in the fabrication of the reflective optics used in EUV lithographic systems, for example. The cleaning process involves ultrasonic cleaning in acetone, methanol, and a pH neutral soap, such as FL-70, followed by rinsing in de-ionized water and drying with dry filtered nitrogen in conjunction with a spin-rinse.

  17. Evaluation of Particle Counter Technology for Detection of Fuel Contamination Detection Utilizing Advanced Aviation Forward Area Refueling System

    DTIC Science & Technology

    2014-01-24

    8, Automatic Particle Counter, cleanliness, free water, Diesel 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT none 18. NUMBER OF...aircraft, or up to 10 mg/L for product used as a diesel product for ground use (1). Free water contamination (droplets) may appear as fine droplets or...published several methods and test procedures for the calibration and use of automatic particle counters. The transition of this technology to the fuel

  18. Particle Count Limits Recommendation for Aviation Fuel

    DTIC Science & Technology

    2015-10-05

    Particle Counter Methodology • Particle counts are taken utilizing calibration methodologies and standardized cleanliness code ratings – ISO 11171 – ISO...Limits Receipt Vehicle Fuel Tank Fuel Injector Aviation Fuel DEF (AUST) 5695B 18/16/13 Parker 18/16/13 14/10/7 Pamas / Parker / Particle Solutions 19/17...12 U.S. DOD 19/17/14/13* Diesel Fuel World Wide Fuel Charter 5th 18/16/13 DEF (AUST) 5695B 18/16/13 Caterpillar 18/16/13 Detroit Diesel 18/16/13 MTU

  19. Innovative Contamination Certification of Multi-Mission Flight Hardware

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.; Hughes, David W.; Montt, Kristina M.; Triolo, Jack J.

    1998-01-01

    Maintaining contamination certification of multi-mission flight hardware is an innovative approach to controlling mission costs. Methods for assessing ground induced degradation between missions have been employed by the Hubble Space Telescope (HST) Project for the multi-mission (servicing) hardware. By maintaining the cleanliness of the hardware between missions, and by controlling the materials added to the hardware during modification and refurbishment both project funding for contamination recertification and schedule have been significantly reduced. These methods will be discussed and HST hardware data will be presented.

  20. Innovative Contamination Certification of Multi-Mission Flight Hardware

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.; Hughes, David W.; Montt, Kristina M.; Triolo, Jack J.

    1999-01-01

    Maintaining contamination certification of multi-mission flight hardware is an innovative approach to controlling mission costs. Methods for assessing ground induced degradation between missions have been employed by the Hubble Space Telescope (HST) Project for the multi-mission (servicing) hardware. By maintaining the cleanliness of the hardware between missions, and by controlling the materials added to the hardware during modification and refurbishment both project funding for contamination recertification and schedule have been significantly reduced. These methods will be discussed and HST hardware data will be presented.

  1. ASRDI Oxygen Technology Survey. Volume 2: Cleaning Requirements, Procedures, and Verification Techniques

    NASA Technical Reports Server (NTRS)

    Bankaitis, H.; Schueller, C. F.

    1972-01-01

    The oxygen system cleaning specifications drawn from 23 industrial and government sources are presented along with cleaning processes employed for meeting these specifications, and recommended postcleaning inspection procedures for establishing the cleanliness achieved. Areas of agreement and difference in the specifications, procedures, and inspection are examined. Also, the lack of clarity or specificity will be discussed. This absence of clarity represents potential safety hazards due to misinterpretation. It can result in exorbitant expenditures of time and money in satisfying unnecessary requirements.

  2. Florence Nightingale and healthcare reform.

    PubMed

    Kudzma, Elizabeth Connelly

    2006-01-01

    The purpose of this article was to examine the work of Florence Nightingale in light of her collaboration with William Farr, the eminent medical statistician. Nightingale's epidemiological investigations supported by Farr illustrated that attention to environmental cleanliness was an important factor in preventing spread of disease. Nightingale channeled her investigations to support hospital reforms and the need for an educated nurse who could provide better management of the hospital environment. Statistical support and solicited criticism allowed Nightingale to argue more forcefully for her reforms.

  3. Implementation of the TOMS contamination control requirements in the former USSR

    NASA Technical Reports Server (NTRS)

    Abrams, Eve M.

    1992-01-01

    The American Total Ozone Mapping Spectrometer (TOMS) was integrated with the Russian Meteor-3 spacecraft and launched on August 15, 1991. Although the TOMS instrument was sensitive to both particulate and molecular contamination, the program for Meteor-3 had not formerly addressed contamination control in ground operations. In order to accommodate the TOMS cleanliness requirements, a contamination control program was successfully established from inception at both the Meteor-3 spacecraft plant near Moscow and at the launch site in Plesetsk.

  4. Analysis of Patient’s Satisfaction with Phlebotomy Services in NABH Accredited Neuropsychiatric Hospital: An Effective Tool for Improvement

    PubMed Central

    Dwivedi, Tanima; Sadhana; Chaudhary, Raju

    2017-01-01

    Introduction Patient’s satisfaction is the need of the hour and one of the most important quality indicators in the laboratory medicine. Aim To assess the patient’s satisfaction with phlebotomy services in a neuropsychiatric hospital by a structured questionnaire with grading scale. Also, identify the problems causing dissatisfactions and to undertake necessary Corrective and Preventative Action (CAPA). Materials and Methods Total 1200 patients were randomly selected over a period of two months (June and July 2016). A structured self designed questionnaire (feedback form) was devised in both Hindi and English languages containing ten questions with a grading scale for each question. It also included suggestions from the users. All the selected patients or their attendants filled up this questionnaire. At the same time, they were also interviewed by phlebotomy staff. A statistical analysis was conducted using SPSS version 16.0 software and Likert scale. Results A total of 94% of the patients were satisfied with the phlebotomy services. Almost 30.0% patients found the phlebotomy services to be very good, but the majority of them (40.5%) found it to be good and another 23.5% found it to be satisfactory while, 4% found the services to be poor and 2% found it to be very poor. The highest rate of satisfaction (4.21) was noted in case of parameter-ease to find collection sample room and lowest rate of satisfaction (3.92) was scored by the parameter-staff’s wearing proper uniform. Depending upon the deficient areas some corrective actions were suggested such as strict compliance of personal protective equipments, regular training to improve technical skill, knowledge and behaviour with emphasis on cleanliness of work area. Conclusion Even though the overall patient’s satisfaction was high, there were areas which needed our attention such as waiting time for phlebotomy procedure, lack of proper sitting arrangement, techniques of sample collection, knowledge of universal precautions etc. Appropriate corrective and preventive actions were taken to solve the problems. Thereby, feedback proved effective in maintenance and improvement of phlebotomy services. PMID:29207713

  5. Analysis of Patient's Satisfaction with Phlebotomy Services in NABH Accredited Neuropsychiatric Hospital: An Effective Tool for Improvement.

    PubMed

    Gupta, Anshu; Dwivedi, Tanima; Sadhana; Chaudhary, Raju

    2017-09-01

    Patient's satisfaction is the need of the hour and one of the most important quality indicators in the laboratory medicine. To assess the patient's satisfaction with phlebotomy services in a neuropsychiatric hospital by a structured questionnaire with grading scale. Also, identify the problems causing dissatisfactions and to undertake necessary Corrective and Preventative Action (CAPA). Total 1200 patients were randomly selected over a period of two months (June and July 2016). A structured self designed questionnaire (feedback form) was devised in both Hindi and English languages containing ten questions with a grading scale for each question. It also included suggestions from the users. All the selected patients or their attendants filled up this questionnaire. At the same time, they were also interviewed by phlebotomy staff. A statistical analysis was conducted using SPSS version 16.0 software and Likert scale. A total of 94% of the patients were satisfied with the phlebotomy services. Almost 30.0% patients found the phlebotomy services to be very good, but the majority of them (40.5%) found it to be good and another 23.5% found it to be satisfactory while, 4% found the services to be poor and 2% found it to be very poor. The highest rate of satisfaction (4.21) was noted in case of parameter-ease to find collection sample room and lowest rate of satisfaction (3.92) was scored by the parameter-staff's wearing proper uniform. Depending upon the deficient areas some corrective actions were suggested such as strict compliance of personal protective equipments, regular training to improve technical skill, knowledge and behaviour with emphasis on cleanliness of work area. Even though the overall patient's satisfaction was high, there were areas which needed our attention such as waiting time for phlebotomy procedure, lack of proper sitting arrangement, techniques of sample collection, knowledge of universal precautions etc. Appropriate corrective and preventive actions were taken to solve the problems. Thereby, feedback proved effective in maintenance and improvement of phlebotomy services.

  6. Willingness to Pay for Improving the Residential Waste Disposal System in Korea: A Choice Experiment Study

    NASA Astrophysics Data System (ADS)

    Ku, Se-Ju; Yoo, Seung-Hoon; Kwak, Seung-Jun

    2009-08-01

    This study attempts to apply choice experiments with regard to the residential waste disposal system (RWDS) in Korea by considering various attributes that are related to RWDS. Using data from a survey conducted on 492 households, the empirical analysis yields estimates of the willingness to pay for a clean food-waste collection facility, the collection of small items (such as obsolete mobile phones and add-ons for personal computers), and a more convenient large waste disposal system. The estimation results of multinomial logit models are quite similar to those of nested logit models. The results reveal that residents have preferences for the cleanliness of facilities and the collection of small items. In Korea, residents are required to purchase and attach stickers for the disposal of large items; they want to be able to obtain stickers at not only village offices but also supermarkets. On the other hand, the frequency of waste collection is not a significant factor in the choice of the improved waste management program.

  7. A study of trends and techniques for space base electronics

    NASA Technical Reports Server (NTRS)

    Trotter, J. D.; Wade, T. E.; Gassaway, J. D.; Mahmood, Q.

    1978-01-01

    A sputtering system was developed to deposit aluminum and aluminum alloys by the dc sputtering technique. This system is designed for a high level of cleanliness and for monitoring the deposition parameters during film preparation. This system is now ready for studying the deposition and annealing parameters upon double-level metal preparation. A technique recently applied for semiconductor analysis, the finite element method, was studied for use in the computer modeling of two dimensional MOS transistor structures. It was concluded that the method has not been sufficiently well developed for confident use at this time. An algorithm was developed for confident use at this time. An algorithm was developed for implementing a computer study which is based upon the finite difference method. The program which was developed was modified and used to calculate redistribution data for boron and phosphorous which had been predeposited by ion implantation with range and straggle conditions. Data were generated for 111 oriented SOS films with redistribution in N2, dry O2 and steam ambients.

  8. SSME Main Combustion Chamber (MCC) hot oil dewaxing

    NASA Technical Reports Server (NTRS)

    Akpati, Anthony U.

    1995-01-01

    In an attempt to comply with the changing environmental regulations, a process was developed for the replacement of perchloroethylene in the dewaxing of the Space Shuttle Main Engine (SSME) Main Combustion Chamber (MCC) and other associated hardware filled with the Rigidax (R) casting compound. Rigidax (R) is a hard blue-dyed, calcium carbonate filled thermoplastic casting compound (melting point 77 C) that is melted and poured into hardware cavities to prevent contamination during material removal processes, i.e. machining, grinding, drilling, and deburring. Additionally, it serves as a maskant for designated areas during electroforming processes. Laboratory testing was conducted to evaluate seven alternate fluids for the replacement of perchloroethylene in the dewaxing process. Based upon successful laboratory results, a mineral oil was selected for testing on actual hardware. The final process developed involves simultaneous immersion and flushing of the MCC channels using a distinct eight stage process. A nonvolatile hydrocarbon analysis of a solvent flush sample is performed to determine the hardware cleanliness for comparison to the previous perchloroethylene dewaxing process.

  9. Willingness to pay for improving the residential waste disposal system in Korea: a choice experiment study.

    PubMed

    Ku, Se-Ju; Yoo, Seung-Hoon; Kwak, Seung-Jun

    2009-08-01

    This study attempts to apply choice experiments with regard to the residential waste disposal system (RWDS) in Korea by considering various attributes that are related to RWDS. Using data from a survey conducted on 492 households, the empirical analysis yields estimates of the willingness to pay for a clean food-waste collection facility, the collection of small items (such as obsolete mobile phones and add-ons for personal computers), and a more convenient large waste disposal system. The estimation results of multinomial logit models are quite similar to those of nested logit models. The results reveal that residents have preferences for the cleanliness of facilities and the collection of small items. In Korea, residents are required to purchase and attach stickers for the disposal of large items; they want to be able to obtain stickers at not only village offices but also supermarkets. On the other hand, the frequency of waste collection is not a significant factor in the choice of the improved waste management program.

  10. Replacement of seam welded hot reheat pipe using narrow groove GTA machine welding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, R.R.; Yanes, J.; Bryant, R.

    1995-12-31

    Southern California Edison, recognizing a potential safety concern, scrutinized its existing seam welded hot reheat pipe manufactured by the same supplier as that which failed. Alternatives were narrowed to two in dealing with the installed seam welded pipe. The overriding consideration, however, was one of safety. With this in mind, the utility company evaluated replacement of the seam welded hot reheat pipe with seamless pipe or increasing the frequency of its inspection program. Although increased inspection was much costly, pipe replacement was chosen due to potential safety concerns with seam welded pipe even with more frequent inspection. The utility companymore » then proceeded to determine the most effective method to complete this work. Analysis showed machine-made (automatic) gas tungsten arc welds (GTAW) as the method of choice due to cleanliness and superior mechanical properties. In conjunction with this method, the narrow groove (3{degree} bevel) weld joint as opposed to the traditional groove (37 1/2{degree} bevel) was shown to provide significant technical advantages.« less

  11. SSME Main Combustion Chamber (MCC) 'Hot Oil' Dewaxing

    NASA Technical Reports Server (NTRS)

    Akpati, Anthony U.

    1994-01-01

    In an attempt to comply with the changing environmental regulations, a process was developed for the replacement of perchloroethylene in the dewaxing of the Space Shuttle Main Engine (SSME) Main Combustion Chamber (MCC) and other associated hardware filled with the Rigidax(registered mark) casting compound. Rigidax(registered mark) is a hard blue-dyed, calcium carbonate filled thermoplastic casting compound (melting point 77 C) that is melted and poured into hardware cavities to prevent contamination during material removal processes, i.e. machining, grinding, drilling, and deburring. Additionally, it serves as a maskant for designated areas during electroforming processes. Laboratory testing was conducted to evaluate seven alternate fluids for the replacement of perchloroethylene in the dewaxing process. Based upon successful laboratory results, a mineral oil was selected for testing on actual hardware. The final process developed involves simultaneous immersion and flushing of the MCC channels using a distinct eight stage process. A nonvolatile hydrocarbon analysis of a solvent flush sample is performed to determine the hardware cleanliness for comparison to the previous perchloroethylene dewaxing process.

  12. Direct Measurement of Trace Elemental Mercury in Hydrocarbon Matrices by Gas Chromatography with Ultraviolet Photometric Detection.

    PubMed

    Gras, Ronda; Luong, Jim; Shellie, Robert A

    2015-11-17

    We introduce a technique for the direct measurement of elemental mercury in light hydrocarbons such as natural gas. We determined elemental mercury at the parts-per-trillion level with high precision [<3% RSD (n = 20 manual injection)] using gas chromatography with ultraviolet photometric detection (GC-UV) at 254 nm. Our approach requires a small sample volume (1 mL) and does not rely on any form of sample preconcentration. The GC-UV separation employs an inert divinylbenzene porous layer open tubular column set to separate mercury from other components in the sample matrix. We incorporated a 10-port gas-sampling valve in the GC-UV system, which enables automated sampling, as well as back flushing capability to enhance system cleanliness and sample throughput. Total analysis time is <2 min, and the procedure is linear over a range of 2-83 μg/m(3) [correlation coefficient of R(2) = 0.998] with a measured recovery of >98% over this range.

  13. Web-Enabled Optoelectronic Particle-Fallout Monitor

    NASA Technical Reports Server (NTRS)

    Lineberger, Lewis P.

    2008-01-01

    A Web-enabled optoelectronic particle- fallout monitor has been developed as a prototype of future such instruments that (l) would be installed in multiple locations for which assurance of cleanliness is required and (2) could be interrogated and controlled in nearly real time by multiple remote users. Like prior particle-fallout monitors, this instrument provides a measure of particles that accumulate on a surface as an indication of the quantity of airborne particulate contaminants. The design of this instrument reflects requirements to: Reduce the cost and complexity of its optoelectronic sensory subsystem relative to those of prior optoelectronic particle fallout monitors while maintaining or improving capabilities; Use existing network and office computers for distributed display and control; Derive electric power for the instrument from a computer network, a wall outlet, or a battery; Provide for Web-based retrieval and analysis of measurement data and of a file containing such ancillary data as a log of command attempts at remote units; and Use the User Datagram Protocol (UDP) for maximum performance and minimal network overhead.

  14. Pattern of Cleanliness with Technology Intervention for Innovation Life

    NASA Astrophysics Data System (ADS)

    Hutari Mulyani, Sitti; Hendrik, Billy; Andhika Putra, Rio; Masril, Mardhiah

    2017-12-01

    Environmental solutions around the world today are making people dependent on technological developments. However, the technology cannot be separated from the community either in the form or its influence, therefore the pattern of behavior of society must also get arrangements for technology to occur as an acceleration of life done properly. This study aims to obtain patterns of community behavior on non-organic waste by using technology intervention. Gap exploration is essential for theoretical and experimental analysis of humans who dispose of unorganic and organic waste out of place. But the field of behavior analysis is uniquely tailored to contribute to this body of work. Sustainable development depends on changing technology to achieve its goals. We report on data collected form an on-line survey, which possible solutions for trash problems. In this paper we present an integrated waste management system with IT that we called I-BSC (Indonesia Bersih (Clean), Sehat (Healty) and Cerdas (Smart)). This I-BSC is not only for deposit bottles and systems but the system aims also to create awareness of waste production and management, which serves as an educational platform in urban environments for further life innovation.

  15. Cleaning at the Edge of Science: NASA's Genesis Mission

    NASA Technical Reports Server (NTRS)

    Stansbery, Eileen K.; Biesinger, Paul H.

    2000-01-01

    As part of NASA's continuing exploration of the origins of our solar system, the California Institute of Technology, Jet Propulsion Laboratory, Lockheed Martin Astronautics, Los Alamos National Laboratory, and the Johnson Space Center are working together to develop the Genesis mission to return solar matter for analysis in terrestrial laboratories. These samples will be used to define a baseline for the chemical and isotopic composition of the solar nebula. Deviations from the baseline resulted as the solar system evolved; thus, providing a tracer for materials incorporated into meteorites, comets and planetary bodies. These differences represent "fossil residues" that provide invaluable insight into how the solar nebula evolved to form the planets. We cannot collect a sample of the Sun as we would for a planet; fortunately, solar material comes to us in the form of the solar wind. Ultrapure materials will be exposed at the Earth-Sun L1, outside the Earth's magnetic influence, where solar wind nuclei will be captured for 2 years before returning to Earth in January 2001. The key challenge to obtaining a good sample of solar wind, uncontaminated by terrestrial atoms, is a clean collection surface in a clean sample canister and clean facilities with which to handle the samples for allocation and future reference. The Johnson Space Center QSQ is responsible for contamination control for the mission, for ensuring the cleanliness of collection surfaces and providing a clean environment for their subsequent handling. The level of cleanliness required is high; at the time of analysis (after sample return), the surface contamination by C, N, O must each be less than 10(exp 15) atoms per centimeter squared and for elements other than C, N, O, the number of atoms per centimeter squared of each surface contaminant shall not exceed the estimated solar wind fluence of the species (varies by element between U at approx. 10 (exp 4) atoms per centimeter squared to Fe, Si, Mg, and Ne at approx. 10(exp 12), atoms per centimeter squared). Typical spacecraft assembly is done in class 10,000 cleanrooms. The final cleaning and reintegration of the Genesis payload canister as well as all sample material handling will be done within a class 10 cleanroom using Dryden suits to protect the collector materials from any human debris. Each component is unique, no standard size, shape, material, or precleaning history. We are developing new final cleaning techniques utilizing ultra-pure water to minimize molecular residues on the hardware components.

  16. Rudimentary Cleaning Compared to Level 300A

    NASA Technical Reports Server (NTRS)

    Arpin, Christina Y. Pina; Stoltzfus, Joel

    2012-01-01

    A study was done to characterize the cleanliness level achievable when using a rudimentary cleaning process, and results were compared to JPR 5322.1G Level 300A. While it is not ideal to clean in a shop environment, some situations (e.g., field combat operations) require oxygen system hardware to be maintained and cleaned to prevent a fire hazard, even though it cannot be sent back to a precision cleaning facility. This study measured the effectiveness of basic shop cleaning. Initially, three items representing parts of an oxygen system were contaminated: a metal plate, valve body, and metal oxygen bottle. The contaminants chosen were those most likely to be introduced to the system during normal use: oil, lubricant, metal shavings/powder, sand, fingerprints, tape, lip balm, and hand lotion. The cleaning process used hot water, soap, various brushes, gaseous nitrogen, water nozzle, plastic trays, scouring pads, and a controlled shop environment. Test subjects were classified into three groups: technical professionals having an appreciation for oxygen hazards; professional precision cleaners; and a group with no previous professional knowledge of oxygen or precision cleaning. Three test subjects were in each group, and each was provided with standard cleaning equipment, a cleaning procedure, and one of each of the three test items to clean. The results indicated that the achievable cleanliness level was independent of the technical knowledge or proficiency of the personnel cleaning the items. Results also showed that achieving a Level 300 particle count was more difficult than achieving a Level A nonvolatile residue amount.

  17. Study of performance loss of Lyman alpha filters due to chemical contamination

    NASA Astrophysics Data System (ADS)

    Faye, Delphine; Zhang, Xueyan; Etcheto, Pierre; Auchère, Frédéric

    2017-05-01

    Observations in the UV and EUV allow many diagnostics of the outer layers of the stars and the Sun so that more and more space telescopes are developed to operate in this fundamental spectral range. However, absorption by residual contaminants coming from polymers outgassing causes critical effects such as loss of signal, spectral shifts, stray light… Thus, a cleanliness and contamination control plan has to be defined to mitigate the risk of damage of sensitive surfaces. In order to specify acceptable cleanliness levels, it is paramount to improve our knowledge and understanding of contamination effects, especially in the UV/EUV range. Therefore, an experimental study has been carried out in collaboration between CNES and IAS, in the frame of the development of the Extreme UV Imager suite for the ESA Solar Orbiter mission; this instrument consists of two High Resolution Imagers and one Full Sun Imager designed for narrow pass-band EUV imaging of the solar corona, and thus very sensitive to contamination. Here, we describe recent results of performance loss measured on representative optical samples. Six narrow pass-band filters, with a multilayer coating designed to select the solar Lyman Alpha emission ray, were contaminated with different amounts of typical chemical species. The transmittance spectra were measured between 100 and 200 nm under high vacuum on the SOLEIL synchrotron beam line. They were compared before and after contamination, and also after a long exposure of the contaminated area to EUV-visible radiations.

  18. Evaluation of food storage racks available on the Polish market in the hygienic context

    PubMed

    Grzesińska, Wiesława; Tomaszewska, Marzena; Bilska, Beata; Trafiałek, Joanna; Dziadek, Michał

    Providing safe food products to the consumer depends on the material and technology used and adherence to hygienic practices, throughout the production process. The degree of microbial contamination of a surface is an important indicator of equipment cleanliness and effectiveness of cleaning and disinfection. Used material, construction solutions and quality of the applied devices also have an effect on hygienic status. The objective of the present study was to evaluate the influence of the design and construction material of selected food storage racks, available on the Polish market, on their hygienic status. The study was based on determination of the capability of microbial growth on the surface of the racks and the effectiveness of their cleaning. Microbiological cleanliness on the surface of the racks was monitored by the contact plates which are able to estimate the total number of icroorganisms. Examination of effectiveness of cleaning was conducted by the use of ATP bioluminescence method. This experiment has proven a significant influence of adopted construction solutions on the hygienic status of the examined racks. Presence of antibacterial layer and a choice of the appropriate construction material characterized by a low surface roughness impedes the microbial growth and increases the effectiveness of cleaning. Design solutions have significant impact on the hygienic status of shelves. Selection of a suitable material for the construction of racks can greatly reduce the possibility of the development of microorganism, despite the low efficiency of the cleaning. The application of antimicrobial coatings inhibits microbial growth.

  19. Replacement of HCFC-225 Solvent for Cleaning NASA Propulsion Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Mitchell, Mark A.; Lowrey, Nikki M.

    2015-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon-225 (HCFC-225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC-225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both the NASA Rocket Propulsion Test Program and the Defense Logistics Agency - Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC-225 that is both an effective cleaner and safe for use with oxygen systems. Candidate solvents were selected and a test plan was developed following the guidelines of ASTM G127, Standard Guide for the Selection of Cleaning Agents for Oxygen Systems. Solvents were evaluated for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Two solvents were determined to be acceptable for cleaning oxygen systems and one was chosen for implementation at NASA's rocket propulsion test facilities. The test program and results are summarized. This project also demonstrated the benefits of cross-agency collaboration in a time of limited resources.

  20. Oral Health Status of Disabled Individuals Attending Special Schools

    PubMed Central

    Altun, Ceyhan; Guven, Gunseli; Akgun, Ozlem Marti; Akkurt, Meltem Derya; Basak, Feridun; Akbulut, Erman

    2010-01-01

    Objectives: The purpose of this study was to determine the prevalence of the dmft-DMFT indexes and the oral hygiene status of 136 individuals attending a special school for the disabled. Methods: Participants were grouped according to disability [Mental Retardation (MR), Cerebral Palsy (CP), Autistic Disorder (AD), Down Syndrome (DS), Other (OTH)] and age [2–6 years (n=24), 7–12 years (50 children) and 13+ years (62 children]. Caries examinations were carried out in accordance with WHO criteria and oral cleanliness was evaluated by visually assessing the presence of plaque on teeth. Results: The age range of patients was 2–26 years (mean age: 11.89±5.19 years). Mean dmft and DMFT scores by age group were as follows: 2–6 years: dmft=2.04±2.24; 7–12 years: dmft=2.24±2.60, DMFT=0.98±2.58; 13+years: DMFT=2.68±2.91. Overall, 15.4% of children had no caries or fillings. While dmft and DMFT levels (P>.05) did not vary significantly by type of disability, oral cleanliness did. Children with autism were observed to maintain the best oral hygiene and those with mental retardation (MR), the poorest. Conclusions: It is important for the dentist to concentrate on a preventive approach and provide proper dental education to parents of disabled individuals. Among the children with disabilities, more attention should be paid to the oral hygiene of MR group. PMID:20922154

  1. Randomized Controlled Trial of Cholestyramine and Hydrotalcite to Eliminate Bile for Capsule Endoscopy

    PubMed Central

    Hong-Bin, Chen; Yue, Huang; Chun, Huang; Shu-Ping, Xiao; Yue, Zhang; Xiao-Lin, Li

    2016-01-01

    Background/Aims: Bile is the main cause of poor bowel preparation for capsule endoscopy (CE). We aimed to determine whether cholestyramine and hydrotalcite can eliminate bile in the bowel. Patients and Methods: Patients undergoing CE were randomized into two groups. Group A patients (n = 75) recieved 250 mL 20% mannitol and 1 L 0.9% saline orally at 20:00 hours on the day before and at 05:00 hours on the day of CE and 20 mL simethicone 30 min before CE. Group B patients (n = 73) were treated identically, except for taking oral cholestyramine and hydrotalcite, starting 3 days before CE. Greenish luminal contents were assessed by four tissue color bar segments using Color Area Statistics software. Bowel cleanliness was evaluated by visualized area percentage assessment of cleansing (AAC) score. Result: Bowel cleanliness (82.7% [62/75] vs 46.6% [34/73]; χ2 = 14.596, P = 0.000). and detected greenish luminal contents (20.0% [15/75] vs 8.2% [6/73]; χ2 = 4.217, P = 0.040) were significantly greater in Group A than in Group B. Greenish luminal contents in the two groups differed significantly in the captured small-bowel (t = −13.74, P = 0.000) segments and proximal small-bowel (t = −0.7365, P = 0.000) segments, but not for the distal small-bowel (t = −0.552, P = 0.581) segments. Conclusions: Cholestyramine and hydrotalcite were ineffective in eliminating bile and improving small-bowel preparation. PMID:26997218

  2. Replacement of Hydrochlorofluorocarbon (HCFC) -225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems

    NASA Technical Reports Server (NTRS)

    Mitchell, Mark A.; Lowrey, Nikki M.

    2015-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon-225 (HCFC-225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC-225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both the NASA Rocket Propulsion Test Program and the Defense Logistics Agency - Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC-225 that is both an effective cleaner and safe for use with oxygen systems. Candidate solvents were selected and a test plan was developed following the guidelines of ASTM G127, Standard Guide for the Selection of Cleaning Agents for Oxygen Systems. Solvents were evaluated for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Two solvents were determined to be acceptable for cleaning oxygen systems and one was chosen for implementation at NASA's rocket propulsion test facilities. The test program and results are summarized. This project also demonstrated the benefits of cross-agency collaboration in a time of limited resources.

  3. Alverine citrate plus simethicone reduces cecal intubation time in colonoscopy - a randomized study.

    PubMed

    Altintaş, Engin; Uçbilek, Enver; Sezgin, Orhan; Sayici, Yasin

    2008-09-01

    Successful colonoscopy depends on the insertion of the instrument to the cecum, a detailed examination, and minimal discomfort to the patient during the procedure. The aim of this study was to determine the effects of alverine citrate plus simethicone on the cecal intubation time, colonic spasm and bowel cleanliness. A prospective, randomized, controlled trial in a consecutive series of patients was conducted to compare alverine citrate as an antispasmodic agent for relaxation of spasm with elective colonoscopy. The drug used consisted of 60 mg alverine citrate plus 300 mg simethicone. Sodium phosphate soda and enema were recommended for bowel cleansing. During colonoscopy, spasticity, difficulty of the procedure, pain, and cleanliness of the colon were scored between 0-4. The time required to reach the cecum was recorded as minutes. Of 165 total patients, 83 and 82 patients were randomized as the drug group (mean age: 51.85+/-13.47 years) and control group (mean age: 51.68+/-16.28 years), respectively. There was a statistically significant difference between the groups in the mean time to reach the cecum in favor of the drug group (7.48+/-3.45 minutes vs. 6.20+/-3.24 minutes; p=0.02). The time to reach the cecum prolonged with an increase in pain score and difficulty score (p=0.0001 and p=0.001, respectively). Alverine citrate plus simethicone reduced the intubation time significantly by 19%, from 7.48 minutes to 6.20 minutes.

  4. Zero-tolerance for faecal contamination of carcasses as a tool in the control of O157 VTEC infections.

    PubMed

    Heuvelink, A E; Roessink, G L; Bosboom, K; de Boer, E

    2001-05-21

    The Dutch government, the meat producers organisation and the meat industry have recognised O157 VTEC as an important public health hazard, and agreed on the necessity to improve the hygiene in Dutch cattle- and calf-slaughtering establishments. This paper reports activities within a national action programme to achieve this objective, "Zero-tolerance for faecal contamination during slaughter of cattle and calves". The study included inspection of hygienic performances in slaughterhouses, and visual and microbiological (aerobic plate counts, Enterobacteriaceae counts and O157 VTEC presence/absence on visually clean cattle and calf carcasses) assessment of carcass cleanliness. Initial studies concluded that the hygienic performances in the Dutch cattle and calf slaughterhouses should be immediately improved. In 52% of the slaughterhouses inspected, carcasses were observed to be contaminated with hide, hair or faeces. Around 45% of the slaughterhouses had constructural deficiencies likely to lead to structural cross-contamination of carcasses, by direct carcass-carcass contact, or by indirect contacts with floors, walls or steps. In 39% of the slaughterhouses, cleaning and disinfection procedures were inadequate. Visual inspection of chilled carcasses found that in 11 of the 27 slaughterhouses visited, more than 10% of the carcasses were visibly contaminated. In 6 of the 27 slaughterhouses visited, more than 50% of the carcasses inspected were visibly contaminated. Microbiological analysis of visually clean carcasses noted contamination levels similar to those reported from other countries. O157 VTEC were not isolated during this study. Circulation of these findings lead to increased efforts by all parties to fulfil the requirements of the statutory "Zero-tolerance" programme. A follow-up study noted a significant decrease in the proportions of faecally contaminated carcasses, i.e., 7% of chilled carcasses were visibly contaminated with faeces, as opposed to 22% contamination during the initial study. The follow-up study also noted a greater awareness of the importance of good hygienic practices among slaughterhouse personnel and government meat inspectors.

  5. Inclusion Behavior During the Electron Beam Button Melting Test

    NASA Astrophysics Data System (ADS)

    Bellot, J. P.; Defay, B.; Jourdan, J.; Chapelle, P.; Jardy, A.

    2012-10-01

    The high mechanical performance of alloys developed for the manufacture of turbine disks depend upon the size and the number density of the inclusions. The electron beam button method has been practiced since the 1980s as a technique to quantify the cleanliness of the superalloys as well as to identify the nature and the size of the inclusions. The technique involves melting the sample into a hemispherical water-cooled crucible and the low density inclusions (mainly oxides) are concentrated by a combination of Marangoni and buoyancy forces into an area at the top surface of the button referred to as the raft. We have experimentally studied the behavior of oxide inclusions in special steels using both high definition video and infrared cameras. We have observed the inversion of the Marangoni effect due to the presence of sulfur, which leads to a positive temperature coefficient of the surface tension. A mathematical modeling has been carried out to simulate the turbulent fluid flow associated with the temperature field in the metallic pool of the button. The surface temperature profile has been successfully compared with the measured data. A post-processor numerical tool calculates the inclusion trajectories taking into account the turbulent fluctuation velocity by a stochastic approach. Hence, the behavior of a population of inclusions has been statistically studied, and the dependence of the capture efficiency on the inclusion size has been analyzed.

  6. ADDRESSING EMERGING ISSUES IN WATER QUALITY ...

    EPA Pesticide Factsheets

    Public concern over cleanliness and safety of source and recreational waters has prompted researchers to look for indicators of water quality. Giving public water authorities multiple tools to measure and monitor levels of chemical contaminants, as well as chemical markers of contamination, simply and rapidly would enhance public protection. The goals of water quality are outlined in the Water Quality Multi-year Plan [http://intranet.epa.gov/ospintra/Planning/wq.pdf] and the research in this task falls under GPRA Goal 2, 2.3.2, Long Term Goals 1, 2, and 4. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and ORD in the area of Water Quality. Located In the subtasks are the various research projects being performed in support of this Task and more in-depth coverage of each project. Briefly, each project's objective is stated below.Subtask 1: To integrate state-of-the-art technologies (polar organic chemical integrative samplers, advanced solid-phase extraction methodologies with liquid chromatography/electrospray/mass spectrometry) and apply them to studying the sources and fate of a select list of PPCPs. Application and improvement of analytical methodologies that can detect non-volatile, polar, water-soluble pharmaceuticals in source waters at levels that could be environmentally significant (at concentrations less than parts per billion, ppb). IAG

  7. Effect of Water, Sanitation, and Hygiene on the Prevention of Trachoma: A Systematic Review and Meta-Analysis

    PubMed Central

    Stocks, Meredith E.; Ogden, Stephanie; Haddad, Danny; Addiss, David G.; McGuire, Courtney; Freeman, Matthew C.

    2014-01-01

    Background Trachoma is the world's leading cause of infectious blindness. The World Health Organization (WHO) has endorsed the SAFE strategy in order to eliminate blindness due to trachoma by 2020 through “surgery,” “antibiotics,” “facial cleanliness,” and “environmental improvement.” While the S and A components have been widely implemented, evidence and specific targets are lacking for the F and E components, of which water, sanitation, and hygiene (WASH) are critical elements. Data on the impact of WASH on trachoma are needed to support policy and program recommendations. Our objective was to systematically review the literature and conduct meta-analyses where possible to report the effects of WASH conditions on trachoma and identify research gaps. Methods and Findings We systematically searched PubMed, Embase, ISI Web of Knowledge, MedCarib, Lilacs, REPIDISCA, DESASTRES, and African Index Medicus databases through October 27, 2013 with no restrictions on language or year of publication. Studies were eligible for inclusion if they reported a measure of the effect of WASH on trachoma, either active disease indicated by observed signs of trachomatous inflammation or Chlamydia trachomatis infection diagnosed using PCR. We identified 86 studies that reported a measure of the effect of WASH on trachoma. To evaluate study quality, we developed a set of criteria derived from the GRADE methodology. Publication bias was assessed using funnel plots. If three or more studies reported measures of effect for a comparable WASH exposure and trachoma outcome, we conducted a random-effects meta-analysis. We conducted 15 meta-analyses for specific exposure-outcome pairs. Access to sanitation was associated with lower trachoma as measured by the presence of trachomatous inflammation-follicular or trachomatous inflammation-intense (TF/TI) (odds ratio [OR] 0.85, 95% CI 0.75–0.95) and C. trachomatis infection (OR 0.67, 95% CI 0.55–0.78). Having a clean face was significantly associated with reduced odds of TF/TI (OR 0.42, 95% CI 0.32–0.52), as were facial cleanliness indicators lack of ocular discharge (OR 0.42, 95% CI 0.23–0.61) and lack of nasal discharge (OR 0.62, 95% CI 0.52–0.72). Facial cleanliness indicators were also associated with reduced odds of C. trachomatis infection: lack of ocular discharge (OR 0.40, 95% CI 0.31–0.49) and lack of nasal discharge (OR 0.56, 95% CI 0.37–0.76). Other hygiene factors found to be significantly associated with reduced TF/TI included face washing at least once daily (OR 0.76, 95% CI 0.57–0.96), face washing at least twice daily (OR 0.85, 95% CI 0.80–0.90), soap use (OR 0.76, 95% CI 0.59–0.93), towel use (OR 0.65, 95% CI 0.53–0.78), and daily bathing practices (OR 0.76, 95% CI 0.53–0.99). Living within 1 km of a water source was not found to be significantly associated with TF/TI or C. trachomatis infection, and the use of sanitation facilities was not found to be significantly associated with TF/TI. Conclusions We found strong evidence to support F and E components of the SAFE strategy. Though limitations included moderate to high heterogenity, low study quality, and the lack of standard definitions, these findings support the importance of WASH in trachoma elimination strategies and the need for the development of standardized approaches to measuring WASH in trachoma control programs. Please see later in the article for the Editors' Summary PMID:24586120

  8. Overcoming the barriers to patient-centred care: time, tools and training.

    PubMed

    West, Elizabeth; Barron, David N; Reeves, Rachel

    2005-04-01

    To investigate whether nurses experience barriers to delivering high quality care in areas that are of particular concern to patients and to describe which aspects of care are most affected when nurses lack the required resources, such as time, tools and training to do their job. Patient surveys conducted in the National Health Service of the United Kingdom tend to show there is variation in the extent to which they are satisfied with care in a number of important areas, such as physical comfort, emotional support and the coordination of care. A sample of nurses working in 20 acute London hospitals was asked to complete a postal questionnaire based on a prototype employee survey developed in the United States and adapted by the authors for use in the United Kingdom. Staff in the human resources departments of participating hospitals mailed the questionnaires to nurses' home addresses. After two reminders, 2880 (out of 6160) useable responses were returned, giving a response rate of 47%. Nurses are aware that there are deficits in standards of care in areas that are particularly important to patients. The majority feel overworked (64%) and report that they do not have enough time to perform essential nursing tasks, such as addressing patients' anxieties, fears and concerns and giving patients and relatives information. Their work is often made more difficult by the lack of staff, space, equipment and cleanliness. They are often unable to control noise and temperature in clinical areas. Nurses in acute London hospitals are subject to high levels of aggressive behaviour, mainly from patients and their relatives, but also from other members of staff. More positively, high proportions of the nurses in our survey expressed the desire for further training, particularly in social and interpersonal aspects of care. This paper goes beyond reporting problems with the quality and safety of care to try to understand why patients do not always receive optimum care in areas that are important to them. In many cases nurses lack the time, tools and training to deliver high quality care in acute London hospitals. We suggest a number of low-cost interventions that might remove some of the barriers to patient-centred care. The questionnaire we have developed could be a useful tool for improving quality locally.

  9. Rapid Biochemical Analysis on the International Space Station (ISS): Preparing for Human Exploration of the Moon and Mars

    NASA Technical Reports Server (NTRS)

    Maule, J.; Morris, Heather; Monaco, L.; Steele, A.; Wainwright, N.

    2008-01-01

    The Lab-on-a-Chip Application Development - Portable Test System, known as LOCAD-PTS, was launched to the International Space Station (ISS) aboard Space Shuttle Discovery (STS-116) on December 9th,2006. Since that time, it has remained onboard ISS and has been operated by the crew on 10 separate occasions LOCAD-PTS is a handheld device for rapid biochemical analysis; it consists of a spectrophotometer, a series of interchangeable cartridges, a pipette and several clean/sterilized swabbing kits to obtain samples from ISS surfaces. Sampling, quantitative analysis and data retrieval is performed onboard, therefore reducing the need to return samples to Earth. Less than 20 minutes are required from sampling to data, significantly faster than existing culture-based methods on ISS, which require 3-5 days. Different cartridges are available for the detection of different target molecules (simply by changing the formulation within each cartridge), thereby maximizing the benefit and applications addressed by a single instrument. Initial tests on ISS have focused on the detection of the bact.erial macromolecule endotoxin, a component of bacterial cell walls. LOCAD-PTS detects endotoxin with a cartridge that contains a formulation known as Limulus Amebocyte Lysate (LAL) assay. LAL is derived from blood of the horseshoe crab, Limulus polyphemus, and detects enodotoxin with an enzyme cascade that triggers generation Of a yellow colored dye, p-nitroanaline. The more p-nitroanaline product, the more endotoxin is in the original sample. To enable quantitative analysis, the absorbance of this color is measured by LOCAD-PTS through a 395 nm filter and compared with an internal calibration curve, to provide a reading on the LED display that ranges from 0.05 Endotoxin Units (EU)/ml to 5 EU/ml. Several surface sites were analyzed within ISS between March 2007 and February 2008, including multiple locations in the US Laboratory Destiny, Node 1 Unity, AMock, and Service Module Zvezda. The goals of this initial study were to i) test the cleanliness of reagents/supplies on orbit, ii) test the crew's ability to collect and process a sample in microgravity without contamination, iii) demonstrate nominal function of the LOCAD-PTS, and iv) provide a general survey of endotoxin within the ISS. The surface sites varied greatly in terms of their frequency-of-use and material texture/composition; from relatively smooth aluminum, to fabric, to the room temperature vulcanizing (RTV) rubber of a Extravehicular Mobility Unit (EMU) spacesuit. Results showed that: i) the swabbing kits and reagents remained clean on orbit, ii) the crew could collect and process a sample without contamination, and iii) the LOCAD-PTS functioned nominally in > 99% of the 55 tests completed. We will present detailed results of the survey of endotoxin on ISS surfaces. These results and technology are important in the near-term - by providing an extra tool in the toolbox for ISS microbial monitoring. They are also important in the longer term as valuable preparation for human exploration of the Moon and Mars. One of the proposed science goals for the human exploration of Mars will be to detect and characterize any indigenous biological molecules that may exist on the Martian surface. To achieve that goal, the crew must have the technology available onboard to differentiate indigenous biology from any terrestrial biological material brought to Mars by the spacecraft and crew (termed 'forward contamination'). The LAL assay is already one of the official methods used by NASA's planetary protection program to certify cleanliness of interplanetary robotic spacecraft prior to launch; and therefore endotoxin is a good marker of forward contamination (as well as other microbial molecules detectable with LOCAD-PTS e.g. box-1, 3-glucan and lipoteichoic acid). Furthermore, the distribution and abundance of these molecules on the ISS provides a good indicator of what to expect on the Crew Exploratioehicle Orion, the lunar lander Antares, and future crewed spacecraft destined for Mars. In addition, technology such as LOCAD-PTS has been proposed to help evaluate forward contamination during lunar surface operations by the crew, as preparation for the human exploration of Mars.

  10. Endotoxins in cotton: washing effects and size distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olenchock, S.A.; Mull, J.C.; Jones, W.G.

    1983-01-01

    Endotoxin contamination was measured in washed and unwashed cottons from three distinct growing areas, California, Mississippi, and Texas. The data show differences in endotoxin contamination based upon the geographic source of the cotton. It is also shown that washing bulk cotton before the carding process results in lower endotoxin in the cotton dust. Washing conditions can affect the endotoxin levels, and all size fractions of the airborne dust contain quantifiable endotoxin contamination. Endotoxin analyses provide a simple and reliable method for monitoring the cleanliness of cotton or airborne cotton dusts.

  11. Welding wire selection critical to jet engine repair work

    NASA Astrophysics Data System (ADS)

    1992-11-01

    A review is provided of issues related to the selection of welding wire for aircraft gas-turbine engines emphasizing the importance of cleanliness in the welding wire product. A three-step metallurgical control process is described for the production of welding wire that is clean and suitable for turbine repair. The process is based on: (1) vacuum induction melting; (2) contamination-free processing of the wire; and (3) environmentally controlled packaging. Weld work on aerospace casting is shown to be useful and suitable for many alloy and superalloy materials with various filler materials.

  12. Army Experience and Requirements for Stability and Cleanliness of Diesel Fuels.

    DTIC Science & Technology

    1980-07-01

    following: Iron Oxide 30 g/1000 gal Quartz Dust 4 g/1 0 0 0 gal Arizona Road Dust = 8 g/1000 gal Cotton Liners 0.1 g/1 0 0 0 gal Naphthenic Acid = 0.03...are then removed , dried, and weighed on a 9 torsion balance. Sediment content is determined by comparing the increase in weight of the test membrane...and thermal instability on the particular diesel fuels would Corrosion in Vehicle create (I) acidic impurities leading to corrosion and water Fuel Tanks

  13. Flight Test Techniques. Proceedings of the Flight Mechanics Panel Symposium Held in Lisbon, Portugal on 2-5 April 1984

    DTIC Science & Technology

    1984-07-01

    results are caused only by the individual aerodynamic cleanliness. A table in thr lower part of this figure gives a, frst impression of the surface quality ...for the Tornado which will be the firso, iarc-iaft in operational service in t•• .. , SGersany and Italy to be so equipped. -nen considering the...and must be tested to the limits of their capability before being released to Service . The. final lesson is that when a high risk trial is undertaken

  14. More on duel purpose solar-electric power plants

    NASA Astrophysics Data System (ADS)

    Hall, F. F.

    Rationale for such plants is reviewed and plant elements are listed. Dual purpose solar-electric plants would generate both electricity and hydrogen gas for conversion to ammonia or methanol or direct use as a fuel of unsurpassed specific power and cleanliness. By-product oxygen would also be sold to owners of hydrogen age equipment. Evolved gasses at high pressure could be fired in compressorless gas turbines, boilerless steam-turbines or fuel-cell-inverter hydrogen-electric power drives of high thermal efficiency as well as in conventional internal combustion engines.

  15. Contamination control program for the Extreme Ultraviolet Explorer instruments

    NASA Technical Reports Server (NTRS)

    Ray, David C.; Malina, Roger F.; Welsh, Barry Y.; Austin, James D.; Teti, Bonnie Gray

    1989-01-01

    A contamination-control program has been instituted for the optical components of the EUV Explorer satellite, whose 80-900 A range performance is easily degraded by particulate and molecular contamination. Cleanliness requirements have been formulated for the design, fabrication, and test phases of these instruments; in addition, contamination-control steps have been taken which prominently include the isolation of sensitive components in a sealed optics cavity. Prelaunch monitoring systems encompass the use of quartz crystal microbalances, particle witness plates, direct flight hardware sampling, and optical witness sampling of EUV scattering and reflectivity.

  16. Wind Turbine Gearbox Oil Filtration and Condition Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Shuangwen

    This is an invited presentation for a pre-conference workshop, titled advances and opportunities in lubrication: wind turbine, at the 2015 Society of Tribologists and Lubrication Engineers (STLE) Tribology Frontiers Conference held in Denver, CO. It gives a brief overview of wind turbine gearbox oil filtration and condition monitoring by highlighting typical industry practices and challenges. The presentation starts with an introduction by covering recent growth of global wind industry, reliability challenges, benefits of oil filtration and condition monitoring, and financial incentives to conduct wind operation and maintenance research, which includes gearbox oil filtration and condition monitoring work presented herein. Then,more » the presentation moves on to oil filtration by stressing the benefits of filtration, discussing typical main- and offline-loop practices, highlighting important factors considered when specifying a filtration system, and illustrating real-world application challenges through a cold-start example. In the next section on oil condition monitoring, a discussion on oil sample analysis, oil debris monitoring, oil cleanliness measurements and filter analysis is given based on testing results mostly obtained by and at NREL, and by pointing out a few challenges with oil sample analysis. The presentation concludes with a brief touch on future research and development (R and D) opportunities. It is hoping that the information presented can inform the STLE community to start or redirect their R and D work to help the wind industry advance.« less

  17. An investigation of radiographers' mobile phone use and the success of an awareness campaign at reducing the nosocomial infection risks.

    PubMed

    Crofton, C C; Foley, S J

    2018-02-01

    Mobile phone use by healthcare workers (HCWs) is widespread. Studies have shown that HCW's mobile phones can harbour pathogens associated with nosocomial infections. This study investigated whether an awareness campaign will result in an improvement in radiographers' phone and hand hygiene practices. Radiographers working in the general department of two university hospitals were invited to participate. One hospital was assigned as the experiment hospital and the other as a control. In the experiment hospital, adenosine triphosphate (ATP) testing of each participant's mobile phone determined the cleanliness of its surface. A corresponding survey was completed to determine their current practices and level of awareness. Subsequently, an infection control poster campaign took place for a one-month period, followed by re-testing. In the control hospital, the ATP testing and survey were also completed before and after a one-month period, but without a poster campaign. Radiographers were generally unaware of the infection risks associated with mobile phone use with 44% of all participants never cleaning their phone. The campaign successfully improved phone hygiene frequency and method in the experiment hospital. However, it did not improve hand hygiene practices and actual phone cleanliness (mean ATP count reductions of 10% (experiment hospital) and 20% (control)). The ATP testing as a less direct form of intervention showed similar levels of success in comparison to the poster campaign. A multifaceted educational approach is likely to be most effective in raising awareness and changing radiographers' phone and hand hygiene practices. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  18. Working relationships of infection prevention and control programs and environmental services and associations with antibiotic-resistant organisms in Canadian acute care hospitals.

    PubMed

    Zoutman, Dick E; Ford, B Douglas; Sopha, Keith

    2014-04-01

    Environmental contamination in hospitals with antibiotic-resistant organisms (AROs) is associated with patient contraction of AROs. This study examined the working relationship of Infection Prevention and Control (IPAC) and Environmental Services and the impact of that relationship on ARO rates. Lead infection control professionals completed an online survey that assessed the IPAC and Environmental Services working relationship in their acute care hospital in 2011. The survey assessed cleaning collaborations, staff training, hospital cleanliness, and nosocomial methicillin-resistant Staphylococcus aureus (MRSA) infection, vancomycin-resistant Enterococcus (VRE) infection, and Clostridium difficile infection (CDI). The survey was completed by 58.3% of hospitals (119 of 204). Two-thirds (65.8%; 77 of 117) of the respondents reported that their cleaners were adequately trained, and 62.4% (73 of 117) reported that their hospital was sufficiently clean. Greater cooperation between IPAC and Environmental Services was associated with lower rates of MRSA infection (r = -0.22; P = .02), and frequent collaboration regarding cleaning protocols was associated with lower rates of VRE infection (r = -0.20; P = .03) and CDI (r = -0.31; P < .001). Canadian IPAC programs generally had collaborative working relationships with Environmental Services, and this was associated with lower rates of ARO. Deficits in the adequacy of cleaning staff training and hospital cleanliness were identified. The promotion of collaborative working relationships and additional training for Environmental Services workers would be expected to lower ARO rates. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  19. Effect of erythromycin on image quality and transit time of capsule endoscopy: A two-center study

    PubMed Central

    Niv, Eva; Bogner, Ido; Barkay, Olga; Halpern, Zamir; Mahajna, Elisabeth; Depsames, Roman; Kopelman, Yael; Fireman, Zvi

    2008-01-01

    AIM: To compare the effect of oral erythromycin vs no preparation with prokinetics on the transit time and the image quality of capsule endoscopy (CE) in evaluating small bowel (SB) pathology. METHODS: We conducted a retrospective, blinded (to the type of preparation) review of 100 CE studies, 50 with no preparation with prokinetics from one medical center (Group A) and 50 from another center with administration of a single dose of 200 mg oral erythromycin 1 h prior to CE (Group B). Gastric, SB and total transit times were calculated, the presence of bile in the duodenum was scored, as was cleanliness within the proximal, middle and distal intestine. RESULTS: The erythromycin group had a slightly shorter gastric transit time (21 min vs 28 min, with no statistical significance). SB transit time was similar for both groups (all P > 0.05). Total transit time was almost identical in both groups. The rate of incomplete examination was 16% for Group A and 10% for Group B (P = 0.37). Bile and cleanliness scores in different parts of the intestine were similar for the two groups (P > 0.05). CONCLUSION: Preparation for capsule endoscopy with erythromycin does not affect SB or total transit time. It tends to reduce gastric transit time, but it does not increase the cecum-reaching rate. Erythromycin does not adversely affect image quality. We consider the routine use of oral erythromycin preparation as being unjustified, although it might be considered in patients with known prolonged gastric emptying time. PMID:18442206

  20. [Blind alleys and misconceptions in public health].

    PubMed

    Müller, H E

    1995-07-01

    The concept of hygiene was created in the 19th century although Hippocrates had already conceived an influence of atmosphere, soil and water on human health. The concept of a public health organisation, however, is a fairly recent one. Environmental and social hygiene were the two poles of the new discipline that focussed on public health. However, the ideologies of capitalism, communism and socialism as well as of social darwinism and "survival of the elite" discredited social hygiene. The decline of totalitarianism was associated with a "loss of face" of state-controlled medicine, including social hygiene. Both the post-World War II German constitution and the previous German statutory health insurance ordinance had blocked it, and hence, no Federal bill on public health was carried. The consequences of this disregard of public health are poor protection by vaccination, a gap in compulsory notification and in epidemics control and high rates of nosocomial infections. Absolutely no development of the science of epidemiology was possible whereas that of medical microbiology is choked by the system now in existence. There is a great misconception within individual hygiene by identifying it merely with cleanliness. Hygiene became a synonym for cleanliness, although that had evolved during a long cultural sociological process centuries before hygiene was established. The modern evolution of the science of hygiene shows the danger that emphasis on healthy lifestyles or on environmental protection may result in regulations and finally in a tyranny that may threaten the liberty of human rights. The so-called "principle of concern" is an example of such irrationality because there is no sensible proportion between risk and expense.

  1. Interventions to maximize facial cleanliness and achieve environmental improvement for trachoma elimination: A review of the grey literature.

    PubMed

    Delea, Maryann G; Solomon, Hiwote; Solomon, Anthony W; Freeman, Matthew C

    2018-01-01

    Efforts are underway to scale-up the facial cleanliness and environmental improvement (F&E) components of the World Health Organization's SAFE strategy for elimination of trachoma as a public health problem. Improving understanding of the F&E intervention landscape could inform advancements prior to scale-up, and lead to more effective and sustained behavior change. We systematically searched for relevant grey literature published from January 1965 through August 2016. Publications were eligible for review if they described interventions addressing F&E in the context of trachoma elimination programs. Subsequent to screening, we mapped attributes of F&E interventions. We then employed three behavior change frameworks to synthesize mapped data and identify potential intervention gaps. We identified 27 documents meeting inclusion criteria. With the exception of some recent programming, F&E interventions have largely focused on intermediate and distal antecedents of behavior change. Evidence from our analyses suggests many interventions are not designed to address documented determinants of improved F&E practices. No reviewed documents endorsed inclusion of intervention components related to behavioral maintenance or resilience-factors critical for sustaining improved behaviors. If left unaddressed, identified gaps in intervention content may continue to challenge uptake and sustainability of improved F&E behaviors. Stakeholders designing and implementing trachoma elimination programs should review their F&E intervention content and delivery approaches with an eye toward improvement, including better alignment with established behavior change theories and empirical evidence. Implementation should move beyond information dissemination, and appropriately employ a variety of behavior change techniques to address more proximal influencers of change.

  2. Reducing health care-associated infections by implementing separated environmental cleaning management measures by using disposable wipes of four colors.

    PubMed

    Wong, Swee Siang; Huang, Cheng Hua; Yang, Chiu Chu; Hsieh, Yi Pei; Kuo, Chen Ni; Chen, Yi Ru; Chen, Li Ching

    2018-01-01

    Environmental cleaning is a fundamental principle of infection control in health care settings. We determined whether implementing separated environmental cleaning management measures in MICU reduced the density of HAI. We performed a 4-month prospective cohort intervention study between August and December 2013, at the MICU of Cathay General hospital. We arranged a training program for all the cleaning staff regarding separated environmental cleaning management measures by using disposable wipes of four colors to clean the patients' bedside areas, areas at a high risk of contamination, paperwork areas, and public areas. Fifteen high-touch surfaces were selected for cleanliness evaluation by using the adenosine triphosphate (ATP) bioluminescence test. Then data regarding HAI densities in the MICU were collected during the baseline, intervention, and late periods. A total of 120 ATP readings were obtained. The total number of clean high-touch surfaces increased from 13% to 53%, whereas that of unclean high-touch surface decreased from 47% to 20%. The densities of HAI were 14.32‰ and 14.90‰ during the baseline and intervention periods, respectively. The HAI density did not decrease after the intervention period, but it decreased to 9.07‰ during the late period. Implementing separated environmental cleaning management measures by using disposable wipes of four colors effectively improves cleanliness in MICU environments. However, no decrease in HAI density was observed within the study period. Considering that achieving high levels of hand-hygiene adherence is difficult, improving environmental cleaning is a crucial adjunctive measure for reducing the incidence of HAIs.

  3. Body mass index, safety hazards, and neighborhood attractiveness.

    PubMed

    Lovasi, Gina S; Bader, Michael D M; Quinn, James; Neckerman, Kathryn; Weiss, Christopher; Rundle, Andrew

    2012-10-01

    Neighborhood attractiveness and safety may encourage physical activity and help individuals maintain a healthy weight. However, these neighborhood characteristics may not be equally relevant to health across all settings and population subgroups. To evaluate whether potentially attractive neighborhood features are associated with lower BMI, whether safety hazards are associated with higher BMI, and whether environment-environment interactions are present such that associations for a particular characteristic are stronger in an otherwise supportive environment. Survey data and measured height and weight were collected from a convenience sample of 13,102 adult New York City (NYC) residents in 2000-2002; data analyses were completed 2008-2012. Built-environment measures based on municipal GIS data sources were constructed within 1-km network buffers to assess walkable urban form (density, land-use mix, transit access); attractiveness (sidewalk cafés, landmark buildings, street trees, street cleanliness); and safety (homicide rate, pedestrian-auto collision and fatality rate). Generalized linear models with cluster-robust SEs controlled for individual and area-based sociodemographic characteristics. The presence of sidewalk cafés, density of landmark buildings, and density of street trees were associated with lower BMI, whereas the proportion of streets rated as clean was associated with higher BMI. Interactions were observed for sidewalk cafés with neighborhood poverty, for street-tree density with walkability, and for street cleanliness with safety. Safety hazard indicators were not independently associated with BMI. Potentially attractive community and natural features were associated with lower BMI among adults in NYC, and there was some evidence of effect modification. Copyright © 2012 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  4. Chemistry and quality of Hibiscus (Hibiscus sabdariffa) for developing the natural-product industry in Senegal.

    PubMed

    Juliani, H R; Welch, C R; Wu, Q; Diouf, B; Malainy, D; Simon, J E

    2009-03-01

    The objectives of this study were to assess and improve the quality of the hibiscus calyces from Senegal over 2 production seasons (2004 to 2005), to develop and adapt new procedures for the determination of hibiscus anthocyanins and analysis of the 2 major ones, delphinidin-3-sambubioside and cyanidin-3-sambubioside. The foreign matter, total ashes, and acid insoluble ashes showed that the calyces harvested in 2005 were produced following hygienic practices, while the color assessment of the calyces and analysis of hibiscus active principles also showed higher amounts of anthocyanins in 2005. A protocol to measure anthocyanins by pH-differential UV-Vis spectrophotometry was adapted to measure the hibiscus anthocyanins from a water extract. The spectrophotometric method for quantitation of total anthocyanins showed a close correlation (r(2)= 0.82) when compared with the HPLC method, suggesting the use of the colorimetric method in quality control programs as an affordable alternative method to assess anthocyanin content in hibiscus. New and raised standards for the cleanliness and active principle content in hibiscus are also proposed. This study demonstrated that the implementation of a quality control program and the application of agricultural good practices in the production and processing of hibiscus calyces can lead to higher quality natural plant products.

  5. Improving student satisfaction of Andalas University Dormitory through Service Quality and Importance Performance Analysis

    NASA Astrophysics Data System (ADS)

    Putri, Nilda Tri; Anggraini, Larisa

    2018-03-01

    Residential satisfaction of university dormitories serve as one of the significant aspects in the framework of sustainability in higher education. This research investigated the quality of dormitory services in Andalas University Dormitory based on student’s satisfaction. According to management residential, the enrollment of residential student has increased gradually in Andalas University. In 2016, capacity of residential student is 1686, but only 1081 students can stay at dormitory because some rooms in bad condition. There are a lot of problems and complaints regarding dormitory’s service quality i.e water problems, leaky rooms and bathrooms, cleanliness and inadequate facilities in residential college. In addition, there are 20% of last year student’s residential check out before the time of contract runs out. The aim of this research are understanding the level of GAP exists between expectation and perception students’ residential in the content of service quality and evaluating the improvement priority services using Importance Performance Analysis. This study is measuring service quality by using Responsiveness, Assurance, Empathy, Reliability and Tangible dimension. A negative GAP indicates that the actual services are than what was expected and the GAP is highlighted area for improvement. Based on IPA, management should improve this following dimension services : responsiveness, tangible and assurance dimension.

  6. Setting a standard: the limulus amebocyte lysate assay and the assessment of microbial contamination on spacecraft surfaces.

    PubMed

    Morris, Heather C; Monaco, Lisa A; Steele, Andrew; Wainwright, Norm

    2010-10-01

    Historically, colony-forming units as determined by plate cultures have been the standard unit for microbiological analysis of environmental samples, medical diagnostics, and products for human use. However, the time and materials required make plate cultures expensive and potentially hazardous in the closed environments of future NASA missions aboard the International Space Station and missions to other Solar System targets. The Limulus Amebocyte Lysate (LAL) assay is an established method for ensuring the sterility and cleanliness of samples in the meat-packing and pharmaceutical industries. Each of these industries has verified numerical requirements for the correct interpretation of results from this assay. The LAL assay is a rapid, point-of-use, verified assay that has already been approved by NASA Planetary Protection as an alternate, molecular method for the examination of outbound spacecraft. We hypothesize that standards for molecular techniques, similar to those used by the pharmaceutical and meat-packing industries, need to be set by space agencies to ensure accurate data interpretation and subsequent decision making. In support of this idea, we present research that has been conducted to relate the LAL assay to plate cultures, and we recommend values obtained from these investigations that could assist in interpretation and analysis of data obtained from the LAL assay.

  7. Profit is a dirty word: the development of the public baths and wash-houses in Britain 1847-1915.

    PubMed

    Sheard, S

    2000-04-01

    Researh on sanitary reform in nineteenth-century Britain has focused mainly on the introduction of large-sanitary infrastructure, especially waterworks and sewage systems. Other sanitary measures such as the provision of public baths and wash-houses have been ignored, or discussed in the limited context of working-class responses to middle-class sanitarianism. Yet by 1915 public baths and wash-houses were to be found in nearly every British town and city. A detailed analysis of these 'enterprises' can provide a useful way of understanding the changing priorities of public health professionals and urban authorities as well as the changing attitudes of the working classes. Connections between personal cleanliness and disease evolved during the century, particularly after the formation of germ theory in the 1880s. This paper demonstrates how the introduction of public baths and wash-houses in Liverpool, Belfast, and Glasgow was initially a direct response to sanitary reform campaigns. It also shows that the explicit public health ideology of these developments was constantly compromised by implicit concerns about municipal finance and the potential profit that such enterprises could generate. This city-based analysis shows that this conflict hindered the full sanitary benefit which these schemes potentially offered.

  8. Qualitative study of influences on food store choice

    PubMed Central

    Krukowski, Rebecca A.; McSweeney, Jean; Sparks, Carla; West, Delia Smith

    2012-01-01

    Previous research indicates food store choice influences dietary intake and may contribute to health disparities. However, there is limited knowledge about the reasons which prompt the choice of a primary food store, particularly among populations vulnerable to obesity and chronic diseases (e.g., individuals living in rural locations and African-Americans). Purposive sampling was used to select rural and urban communities (3 African-American and 2 Caucasian focus groups; n=48) in Arkansas from June to November 2010, allowing examination of potential racial or rurality differences. Primary household food shoppers (n=48) (96% female, 63% African-American, mean age=48.1±13.9 years old, mean BMI=30.5±7.8) discussed reasons for choosing their primary store. Qualitative analysis techniques—content analysis and constant comparison—were used to identify themes. Four themes emerged: proximity to home or work, financial considerations and strategies, availability/quality of fruits, vegetables, and meat, and store characteristics (e.g., safety, cleanliness/smell, customer service, nonfood merchandise availability, and brand availability). While there were persistent rurality differences, the relevant factors were similar between African-American and Caucasian participants. These findings have important implications for future policies and programs promoting environmental changes related to dietary intake and obesity, particularly in rural areas that appear to have significant challenges in food store choice. PMID:22771756

  9. Advanced Curation: Solving Current and Future Sample Return Problems

    NASA Technical Reports Server (NTRS)

    Fries, M.; Calaway, M.; Evans, C.; McCubbin, F.

    2015-01-01

    Advanced Curation is a wide-ranging and comprehensive research and development effort at NASA Johnson Space Center that identifies and remediates sample related issues. For current collections, Advanced Curation investigates new cleaning, verification, and analytical techniques to assess their suitability for improving curation processes. Specific needs are also assessed for future sample return missions. For each need, a written plan is drawn up to achieve the requirement. The plan draws while upon current Curation practices, input from Curators, the analytical expertise of the Astromaterials Research and Exploration Science (ARES) team, and suitable standards maintained by ISO, IEST, NIST and other institutions. Additionally, new technologies are adopted on the bases of need and availability. Implementation plans are tested using customized trial programs with statistically robust courses of measurement, and are iterated if necessary until an implementable protocol is established. Upcoming and potential NASA missions such as OSIRIS-REx, the Asteroid Retrieval Mission (ARM), sample return missions in the New Frontiers program, and Mars sample return (MSR) all feature new difficulties and specialized sample handling requirements. The Mars 2020 mission in particular poses a suite of challenges since the mission will cache martian samples for possible return to Earth. In anticipation of future MSR, the following problems are among those under investigation: What is the most efficient means to achieve the less than 1.0 ng/sq cm total organic carbon (TOC) cleanliness required for all sample handling hardware? How do we maintain and verify cleanliness at this level? The Mars 2020 Organic Contamination Panel (OCP) predicts that organic carbon, if present, will be present at the "one to tens" of ppb level in martian near-surface samples. The same samples will likely contain wt% perchlorate salts, or approximately 1,000,000x as much perchlorate oxidizer as organic carbon. The chemical kinetics of this reaction are poorly understood at present under the conditions of cached or curated martian samples. Among other parameters, what is the maximum temperature allowed during storage in order to preserve native martian organic compounds for analysis? What is the best means to collect headspace gases from cached martian (and other) samples? This gas will contain not only martian atmosphere but also off-gassed volatiles from the cached solids.

  10. [Hygienic Inspections of Ventilation Systems Under Resting Conditions (According to DIN 1946-4:1999-03) - A Retrospective Assessment].

    PubMed

    Friedrich, Lena; Boeckelmann, Irina

    2018-01-11

    Hygienic and microbiologically sterile air quality is essential for successful guideline-based work in operating theatres. To ensure clean air and to reduce contamination during surgery, ventilation systems are indispensable. Ventilation systems should be especially designed to keep the number of particles and germs under statutory limits. Therefore, they must be operated to recognised standards of good practice and be periodically inspected and maintained. The objective of this study was to prove, through the analysis of observation outside surgery time (rest condition), the effects of ventilation systems on air quality in a medical facility. Measurements were taken in 34 operating theatres annually over a period of ten years outside surgery time (resting condition) but with the air ventilation system operating under full load. 29 operating theatres were provided with laminar air flow and five theatres with turbulent air flow systems. In each operating theatre, air cleanliness was analysed by measuring the amount of airborne particles and airborne germs. Measuring points were determined 10 mm beneath the supply-air ceiling in the centre of the operating theatre and at one position outside the supply-air ceiling. The number of airborne particles at the supply-air ceiling was between 0/m³ and 4,441/m³ of air and, as such, the limiting factor was never exceeded. However, airborne germ measurements of between 0 CFU/m³ and 200 CFU/m³ (CFU: colony forming units) demonstrated that the limiting factor for this criterion was exceeded in 10.9% of occasions. In general, the values in the middle of the room were higher than at the supply-air ceiling. There were significant differences (p < 0.001) between the values at the supply-air ceiling, the surgery table and the values outside the supply-air ceiling. The results show the positive impact of ventilation systems on the air cleanliness in operating theatres. However, laminar airflow systems seem to create cleaner air than conventional ventilation systems. The size of the supply-air ceiling plays an important role in the prevention of the contamination of the staff, the surgical field, the instrument table and the patient. However, the effect on surgical site infections has not been verified. Improved measuring methods should be considered. Georg Thieme Verlag KG Stuttgart · New York.

  11. Organic cleanliness of the Mars Science Laboratory sample transfer chain.

    PubMed

    Blakkolb, B; Logan, C; Jandura, L; Okon, A; Anderson, M; Katz, I; Aveni, G; Brown, K; Chung, S; Ferraro, N; Limonadi, D; Melko, J; Mennella, J; Yavrouian, A

    2014-07-01

    One of the primary science goals of the Mars Science Laboratory (MSL) Rover, Curiosity, is the detection of organics in Mars rock and regolith. To achieve this, the Curiosity rover includes a robotic sampling system that acquires rock and regolith samples and delivers it to the Sample Analysis at Mars (SAM) instrument on board the rover. In order to provide confidence that any significant organics detection result was Martian and not terrestrial in origin, a requirement was levied on the flight system (i.e., all sources minus the SAM instrument) to impart no more than 36 parts per billion (ppb by weight) of total reduced carbon terrestrial contamination to any sample transferred to the SAM instrument. This very clean level was achieved by a combination of a rigorous contamination control program on the project, and then using the first collected samples for a "dilution cleaning" campaign of the sample chain prior to delivering a sample to the SAM instrument. Direct cleanliness assays of the sample-contacting and other Flight System surfaces during pre-launch processing were used as inputs to determine the number of dilution cleaning samples needed once on Mars, to enable delivery of suitably clean samples to the SAM experiment. Taking into account contaminant redistribution during launch thorough landing of the MSL on Mars, the amount of residue present on the sampling hardware prior to the time of first dilution cleaning sample acquisition was estimated to be 60 ng/cm(2) on exposed outer surfaces of the sampling hardware and 20 ng/cm(2) on internal sample contacting surfaces; residues consisting mainly of aliphatic hydrocarbons and esters. After three dilution cleaning samples, estimated in-sample contamination level for the first regolith sample delivered to the SAM instrument at the Gale Crater "Rocknest" site was bounded at ≤10 ppb total organic carbon. A Project decision to forego ejecting the dilution cleaning sample and instead transfer the first drill-acquired sample at the "John Klein" site to SAM resulted in an estimated level of terrestrial contamination of ≤430 ppb. The estimated terrestrial contamination for portions from the second drill-acquired sample, at Cumberland, was ≤69 ppb; the estimate for a future, third, drilled sample is ≤38 ppb. These levels are comparable in magnitude to the SAM instrument blanks at the nanomole level (as chlorohydrocarbon).

  12. NCW 2002: Chemistry Keeps Us Clean. Chemists Clean Up: A History and Exploration of the Craft of Soapmaking How Soap Came to be Common in America

    NASA Astrophysics Data System (ADS)

    Kostka, Kim; McKay, David D.

    2002-10-01

    Soap is an article whose commonplace presence and obvious necessity we take for granted at the dawn of the twenty-first century. For most of American history bath soap, however, was a luxury product. This paper explores the confluence of the cultural and technological changes that led to its transformation into the ubiquitous and well-used object it is today. We pick up the timeline for the development of soap in the early American republic when soapmaking was a householder's task and soap use was generally limited to laundering clothes. We then trace the rise of the American cleanliness movement and correlate this rise to the increased manufacturing capabilities of the nation's large soapmakers. This technological forward movement included improvements in producing alkalis as well as the inception and growth of the oleochemicals industry. Additional growth agents were the development of market analysis, advertising campaigns, and factory-scale hydrolysis of fatty acids from their parent fats.

    See Featured Molecules.

  13. Children's understanding of and motivations for toothbrushing: a qualitative study.

    PubMed

    Gill, P; Stewart, K; Chetcuti, D; Chestnutt, I G

    2011-02-01

    To explore children's understanding of why they do or do not brush their teeth and their motivations for toothbrushing. Individual semi-structured interviews were conducted with 66 children aged 6-7 years and 10-11 years in four purposively selected primary schools in Cardiff, UK. Data were analysed using a constructive process of Thematic Content Analysis and techniques of open and selective coding. While a routine activity, toothbrushing was prompted rather than monitored by parents and easily fell by the wayside because of tiredness, excitement or distraction. Rationalizations for toothbrushing were poorly formed in the children's accounts and related to 'doom scenarios' such as teeth falling out, or to issues of personal grooming and cleanliness rather than caries prevention. Electric (powered) toothbrushes were popular and had engaged the children's interest. Social and domestic circumstances, such as when children stayed with different parents at different times, impacted on toothbrushing routines. This study has revealed information that is of value in directing oral health education messages, oral health promotion programmes and has identified issues that potentially affect compliance with toothbrushing that merit further investigation. © 2010 John Wiley & Sons A/S.

  14. Latest developments on EUV reticle and pellicle research and technology at TNO

    NASA Astrophysics Data System (ADS)

    Verberk, Rogier; Koster, Norbert; te Sligte, Edwin; Staring, Wilbert

    2017-06-01

    At TNO an extensive EUV optics life time program has been running for over 15 years together with our partners ASML and Carl Zeiss. This has contributed to the upcoming introduction of EUV High Volume Manufacturing (HVM). To further help the industry with the introduction of EUV, TNO has worked on extending their facilities with a number of reticle and pellicle research infrastructure facilities. In this paper we will show some of the facilities that are available at TNO and shortly introduce their capabilities. Recently we have opened our EBL2 facility, which is an EUV Beam Line (EBL2) meant for studying the effects of high power EUV illumination on optics, reticles and pellicles up to the power roadmap of 500 W at intermediate Focus (IF). This facility is open to users from all over the world and is beneficial for the industry in helping developing alternative capping layers and contamination control strategies for optics lifetime, new absorber materials, pellicles and resists. The EBL2 system has seen first light in December 2016 and is now in the final stage of acceptance testing and qualification. It is expected that the system will be fully operational in the third quarter of 2017, and available for users. It is possible to transfer reticles to and from the EBL2 by means of the reticle handler using the dual pod interface. This secures backside cleanliness to NXE standards and thus enables wafer printing on a NXE tool in a later stage after the exposures and inspection at EBL2. Besides EBL2, a high performance and ultra-clean reticle handler is available at TNO. This handler incorporates our particle scanner Rapid Nano 4 for front side inspection of reticle blanks with a detection limit down to 20 nm particles. Attached to the handler is also an Optical Coherence Tomography (OCT) inspection tool for back-side reticle or pellicle inspection with a resolution down to 1 micron.

  15. Development of an on-line aqueous particle sensor to study the performance of inclusions in a 12 tonne, delta shaped full scale water model tundish

    NASA Astrophysics Data System (ADS)

    Chakraborty, Abhishek

    Detection of particulate matter thinly dispersed in a fluid medium with the aid of the difference in electrical conductivity between the pure fluid and the particles has been practiced at least since the last 50 to 60 years. The first such instruments were employed to measure cell counts in samples of biological fluid. Following a detailed study of the physics and principles operating within the device, called the Electric Sensing Zone (ESZ) principle, a new device called the Liquid Metal Cleanliness Analyzer (LiMCA) was invented which could measure and count particles of inclusions in molten metal. It provided a fast and fairly accurate tool to make online measurement of the quality of steel during refining and casting operations. On similar lines of development as the LiMCA, a water analogue of the device called, the Aqueous Particle Sensor (APS) was developed for physical modeling experiments of metal refining operations involving water models. The APS can detect and measure simulated particles of inclusions added to the working fluid (water). The present study involves the designing, building and final application of a new and improved APS in water modeling experiments to study inclusion behavior in a tundish operation. The custom built instrument shows superior performance and applicability in experiments involving physical modeling of metal refining operations, compared to its commercial counterparts. In addition to higher accuracy and range of operating parameters, its capability to take real-time experimental data for extended periods of time helps to reduce the total number of experiments required to reach a result, and makes it suitable for analyzing temporal changes occurring in unsteady systems. With the modern impetus on the quality of the final product of metallurgical operations, the new APS can prove to be an indispensable research tool to study and put forward innovative design and parametric changes in industrially practised metallurgical operations.

  16. Minimization of nanosatellite low frequency magnetic fields.

    PubMed

    Belyayev, S M; Dudkin, F L

    2016-03-01

    Small weight and dimensions of the micro- and nanosatellites constrain researchers to place electromagnetic sensors on short booms or on the satellite body. Therefore the electromagnetic cleanliness of such satellites becomes a central question. This paper describes the theoretical base and practical techniques for determining the parameters of DC and very low frequency magnetic interference sources. One of such sources is satellite magnetization, the reduction of which improves the accuracy and stability of the attitude control system. We present design solutions for magnetically clean spacecraft, testing equipment, and technology for magnetic moment measurements, which are more convenient, efficient, and accurate than the conventional ones.

  17. Measurement of single crystal surface parameters

    NASA Technical Reports Server (NTRS)

    Swanson, L. W.; Bell, A. E.; Strayer, R. W.

    1972-01-01

    The sticking coefficient and thermal desorption spectra of Cs from the (110) plane of W was investigated. A sticking coefficient of unity for the monolayer region was measured for T 250 K. Several distinct binding states were observed in the thermal desorption spectrum. Work function and electron reflection measurements were made on the (110) and (100) crystal faces of Mo. Both LEED and Auger were used to determine the orientation and cleanliness of the crystal surfaces. The work function values obtained for the (110) and (100) planes of Mo were 4.92 and 4.18 eV respectively.

  18. Using Ozone To Clean and Passivate Oxygen-Handling Hardware

    NASA Technical Reports Server (NTRS)

    Torrance, Paul; Biesinger, Paul

    2009-01-01

    A proposed method of cleaning, passivating, and verifying the cleanliness of oxygen-handling hardware would extend the established art of cleaning by use of ozone. As used here, "cleaning" signifies ridding all exposed surfaces of combustible (in particular, carbon-based) contaminants. The method calls for exposing the surfaces of the hardware to ozone while monitoring the ozone effluent for carbon dioxide. The ozone would passivate the hardware while oxidizing carbon-based residues, converting the carbon in them to carbon dioxide. The exposure to ozone would be continued until no more carbon dioxide was detected, signifying that cleaning and passivation were complete.

  19. The SAFE strategy for the elimination of trachoma by 2020: will it work?

    PubMed Central

    Bailey, R.; Lietman, T.

    2001-01-01

    WHO has recently launched a programme (GET 2020) for the elimination of trachoma, the leading cause of preventable blindness. GET 2020 has adopted the SAFE strategy, a comprehensive set of control measures (Surgery for entropion/trichiasis; Antibiotics for infectious trachoma; Facial cleanliness to reduce transmission; Environmental improvements such as control of disease-spreading flies and access to clean water). The present article reviews the strengths and weaknesses of each component of the strategy. Although significant hurdles remain to be overcome there is every reason to hope that GET 2020 will be successful. PMID:11285668

  20. Note: Work function change measurement via improved Anderson method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sabik, A., E-mail: sabik@ifd.uni.wroc.pl; Gołek, F.; Antczak, G.

    We propose the modification to the Anderson method of work function change (Δϕ) measurements. In this technique, the kinetic energy of the probing electrons is already low enough for non-destructive investigation of delicate molecular systems. However, in our implementation, all electrodes including filament of the electron gun are polarized positively. As a consequence, electron bombardment of any elements of experimental system is eliminated. Our modification improves cleanliness of the ultra-high vacuum system. As an illustration of the solution capabilities, we present Δϕ of the Ag(100) surface induced by cobalt phthalocyanine layers.

  1. Sterilization, high-level disinfection, and environmental cleaning.

    PubMed

    Rutala, William A; Weber, David J

    2011-03-01

    Failure to perform proper disinfection and sterilization of medical devices may lead to introduction of pathogens, resulting in infection. New techniques have been developed for achieving high-level disinfection and adequate environmental cleanliness. This article examines new technologies for sterilization and high-level disinfection of critical and semicritical items, respectively, and because semicritical items carry the greatest risk of infection, the authors discuss reprocessing semicritical items such as endoscopes and automated endoscope reprocessors, endocavitary probes, prostate biopsy probes, tonometers, laryngoscopes, and infrared coagulation devices. In addition, current issues and practices associated with environmental cleaning are reviewed. Copyright © 2011. Published by Elsevier Inc.

  2. The effect of environmental initiatives on NASA specifications and standards activities

    NASA Technical Reports Server (NTRS)

    Griffin, Dennis; Webb, David; Cook, Beth

    1995-01-01

    The NASA Operational Environment Team (NOET) has conducted a survey of NASA centers specifications and standards that require the use of Ozone Depleting Substances (ODS's) (Chlorofluorocarbons (CFCs), Halons, and chlorinated solvents). The results of this survey are presented here, along with a pathfinder approach utilized at Marshall Space Flight Center (MSFC) to eliminate the use of ODS's in targeted specifications and standards. Presented here are the lessons learned from a pathfinder effort to replace CFC-113 in a significant MSFC specification for cleaning and cleanliness verification methods for oxygen, fuel and pneumatic service, including Shuttle propulsion elements.

  3. The GOES In-Situ Geomagnetism Experiment Reimagined

    NASA Technical Reports Server (NTRS)

    Abraham, Bereket; Chu, Donald; Comeyne, Gustave J.; Concha, Marco; Fellows, David W.; Heacock, Matthew G.; Tadikonda, Sivakumara K.

    2017-01-01

    The Geostationary Operational Environmental Satellites (GOES) carry several instruments each with its own requirements. Because accommodating all of them is difficult, there is interest in putting some on their own smaller platforms. The simplest instruments are the magnetometers. These are small and have low communication, attitude control and cleanliness requirements. Getting on-station and operating in close proximity with another satellite, however, requires significant propulsion capabilities. This paper describes a CubeSat mission that goes from geo-transfer to geostationary orbit and operates next to a GOES spacecraft. Requirements, a notional design and performance predictions are provided.

  4. Effects of alternative deep bedding options on dairy cow preference, lying behavior, cleanliness, and teat end contamination.

    PubMed

    Wolfe, T; Vasseur, E; DeVries, T J; Bergeron, R

    2018-01-01

    Cows spend more time lying down when stalls are soft and dry, and bedding plays a key role in the comfort of the lying surface. The first objective of this study (experiment 1) was to compare cow preference for 2 types of alternative deep-bedding materials, switchgrass and switchgrass-lime, using wheat straw on a rubber mat as a control. Nine Holstein lactating cows were submitted in trios to a 3-choice preference test over 14 d (2 d of adaptation, 3 d of restriction to each stall, and 3 d of free access to all 3 stalls). Cows were housed individually in pens containing 3 stalls with different lying surfaces: (1) rubber mat with chopped wheat straw (WS); (2) deep-bedded switchgrass (SG); and (3) deep-bedded switchgrass, water, and lime mixture (SGL). The second objective (experiment 2) was to test, in freestall housing, the effects of these 3 types of bedding on lying behavior, cow cleanliness, and teat end bacterial contamination. Bedding treatments were compared in a 3 × 3 Latin square design using 24 cows split into groups of 8, with bedding materials being switched every 4 wk. Lying behavior was measured with data loggers in both studies. During experiment 1, cows chose to spend more time lying and had more frequent lying bouts on SG (9.4 h/d; 8.2 bouts/d) than on SGL (1.0 h/d; 0.9 bouts/d). They also spent more time standing and stood more frequently in stalls with SG (2.0 h/d; 10.1 bouts/d) than in those with SGL (0.6 h/d; 2.6 bouts/d), and stood longer in stalls with SG than with WS (0.6 h/d). In experiment 2, the total lying time, frequency of lying bouts, and mean lying bout duration were, on average, 9.7 ± 1.03 h/d, 8.2 ± 0.93 bouts/d, and 1.2 ± 0.06 h/bout, respectively, and did not differ between treatments. No treatment effects were found for cow cleanliness scores. Bedding dry matter was highest for SG (74.1%), lowest for SGL (63.5%), and intermediate for WS (68.6%) [standard error of the mean (SEM) = 1.57%]. This may explain the higher teat end count of coliforms for cows on SGL (0.92 log 10 cfu/g) compared with WS (0.13 log 10 cfu/g) (SEM = 0.144 log 10 cfu/g). In conclusion, cows preferred the deep-bedded switchgrass surface over the other 2 surfaces, and deep-bedded switchgrass appears to be a suitable bedding alternative for dairy cows. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. In-situ protein determination to monitor contamination in a centrifugal partition chromatograph.

    PubMed

    Bouiche, Feriel; Faure, Karine

    2017-05-15

    Centrifugal partition chromatography (CPC) works with biphasic liquid systems including aqueous two-phase systems. Metallic rotors are able to retain an aqueous stationary phase able to purify proteins. But the adhesion of proteins to solid surface may pose a cross-contamination risk during downstream processes. So it is of utmost importance to ensure the cleanliness of the equipment and detect possible protein contamination in a timely manner. Thereby, a direct method that allows the determination of the effective presence of proteins and the extent of contamination in the metallic CPC rotors was developed. This in-situ method is derived from the Amino Density Estimation by Colorimetric Assay (ADECA) which is based on the affinity of a dye, Coomassie Brillant Blue (CBB), with protonated N + groups of the proteins. In this paper, the ADECA method was developed dynamically, on a 25 mL stainless-steel rotor with various extents of protein contaminations using bovine serum albumin (BSA) as a fouling model. The eluted CBB dye was quantified and found to respond linearly to BSA contamination up to 70 mg injected. Limits of detection and quantification were recorded as 0.9 mg and 3.1 mg, respectively. While the non-specific interactions between the dye and the rotor cannot currently be neglected, this method allows for in situ determination of proteins contamination and should contribute to the development of CPC as a separation tool in protein purification processes. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Assessing obstetric patient experience: a SERVQUAL questionnaire.

    PubMed

    Garrard, Francesca; Narayan, Harini

    2013-01-01

    Across health services, there is a drive to respond to patient feedback and to incorporate their views into service improvement. The SERVQUAL method has been used in several clinical settings to quantify whether services meet patient expectations. However, work has been limited in the obstetric population. This paper seeks to address these issues. This study used an adapted SERVQUAL questionnaire to assess a reconfigured antenatal clinic service. The most important care aspects, as rated by patients, were used to construct the SERVQUAL questions. The questionnaire was administered to eligible women in two parts. The first was completed before their first hospital antenatal appointment and the second either at home (a postal-chasing exercise) or while waiting for their next appointment. Only fully completed questionnaires (both parts) were analysed. Service strengths included staff politeness, patient respect and privacy. Areas for improvement included hand cleanliness, women's involvement in decision making and communicating risk. However, the low variability in patient responses makes concrete conclusions difficult and methodological issues complicate evaluating hand cleanliness. The new antenatal clinic service received low negative weighted and un-weighted overall scores. The SERVQUAL measure was developed from patient feedback and used to further improve services. The SERVQUAL-based measure allowed an internal evaluation of patient experience and highlighted areas for improvement. However, without validation, the questionnaire cannot be used as an outcome measure and variation between published SERVQUAL questionnaires makes comparisons difficult. This highlights an important balance in patient evaluation measures--between locally responsive and externally comparable. The SERVQUAL approach allows healthcare teams to evaluate patient experience, while accounting for variation in their expectations and priorities. The study highlights several areas that are important to obstetric patients, where expectation scores are high. However, the similar means and small samples left little difference between excellence and room for improvement.

  7. Nonwoven Fabric Uses and Prospects in Human Space Flight

    NASA Technical Reports Server (NTRS)

    Bacon, Jack

    2001-01-01

    The US space shuttle fleet has been flying for over 20 years. Although the shuttle operates in a unique exterior environment, the interior is intentionally made to be as close to the "normal" human environment as possible. The filtration needs of the shuttle are not substantially different from those of a large mobile home or camper, supporting the needs of a family of seven for up to two weeks. Therefore, most of the materials that are used to filter the air, water, and other fluids on the Shuttle are similar or identical to those employed in other sectors of the transportation industry. The only significantly different feature of the space environment is the unique "three-phase" nature of the air (with suspended liquids and solids ranging in size from aerosol droplets to binoculars). Such suspended debris contributes to the air filtration and waste management problem. Careful flow management and cleanliness practices help to mitigate the effect of debris, and liquid spills are rare, seldom making it to the filters. (It has been common on all spacecraft to look first for lost items on the air intake filters, since all objects ultimately migrate there in the flow. Liquids tend to seep rather than "spill", and so tend to aggregate in a ball near the source.) In addition to the basic fluids of the interior environment (water and water wastes, air, and its constituent supply gasses) the shuttle also has unfiltered fluid systems for Freon, hydrogen, helium, ammonia, hydraulic fluid, and propellants. Only the propellant system, owing to its uncommon chemistry, represents a fluid system that is not typical of household or medical applications. Careful external filtration prior to flight assures the cleanliness in these closed systems.

  8. Interventions to maximize facial cleanliness and achieve environmental improvement for trachoma elimination: A review of the grey literature

    PubMed Central

    Solomon, Hiwote; Solomon, Anthony W.; Freeman, Matthew C.

    2018-01-01

    Background Efforts are underway to scale-up the facial cleanliness and environmental improvement (F&E) components of the World Health Organization’s SAFE strategy for elimination of trachoma as a public health problem. Improving understanding of the F&E intervention landscape could inform advancements prior to scale-up, and lead to more effective and sustained behavior change. Methods/findings We systematically searched for relevant grey literature published from January 1965 through August 2016. Publications were eligible for review if they described interventions addressing F&E in the context of trachoma elimination programs. Subsequent to screening, we mapped attributes of F&E interventions. We then employed three behavior change frameworks to synthesize mapped data and identify potential intervention gaps. We identified 27 documents meeting inclusion criteria. With the exception of some recent programming, F&E interventions have largely focused on intermediate and distal antecedents of behavior change. Evidence from our analyses suggests many interventions are not designed to address documented determinants of improved F&E practices. No reviewed documents endorsed inclusion of intervention components related to behavioral maintenance or resilience–factors critical for sustaining improved behaviors. Conclusions If left unaddressed, identified gaps in intervention content may continue to challenge uptake and sustainability of improved F&E behaviors. Stakeholders designing and implementing trachoma elimination programs should review their F&E intervention content and delivery approaches with an eye toward improvement, including better alignment with established behavior change theories and empirical evidence. Implementation should move beyond information dissemination, and appropriately employ a variety of behavior change techniques to address more proximal influencers of change. PMID:29370169

  9. Factors associated with different hygiene practices in the homes of 15 month old infants

    PubMed Central

    Sherriff, A; Golding, J; The, A

    2002-01-01

    Background: Improved hygiene in Westernised regions of the world may be partly responsible for the increased prevalence of diseases of the immune system, such as asthma and atopy. There is a paucity of data on cleanliness norms in young children in the UK and there has been no attempt to identify factors that influence the adoption of particular hygiene practices in the home. Aims: To examine levels of hygiene in a contemporary cohort of children and identify social and lifestyle factors influencing hygiene practices in the home. Methods: The sample under study are participants in the Avon Longitudinal Study of Parents and Children (ALSPAC). Parental self completion questionnaires provided data on hygiene levels in children at 15 months of age, and a hygiene score was derived from these responses. Multivariable logistic regression models investigated associations between high hygiene scores (top quintile) and a number of perinatal, maternal, social, and environmental factors. Results: Maternal smoking during pregnancy, low maternal educational achievement, and living in local authority housing were factors independently associated with high hygiene scores, as was increased use of chemical household products. High hygiene scores were inversely related to living in damp housing and attendance at day care. There were no gender or ethnic differences in hygiene score. Conclusion: Important data on cleanliness norms for infants have been presented. The adoption of hygiene practices is influenced to some degree by social, lifestyle, and environmental factors—with higher hygiene scores occurring in more socially disadvantaged groups. Increased use of chemical household products in the more socially disadvantaged groups within ALSPAC has emerged as an important confounder in any study of hygiene and ill health. PMID:12089118

  10. Effect of hand hygiene and glove use on cleanliness of reusable surgical instruments.

    PubMed

    Costa, D M; Lopes, L K O; Tipple, A F V; Castillo, R B; Hu, H; Deva, A K; Vickery, K

    2017-12-01

    During functionality testing and packaging of reusable surgical instruments (RSI) for sterilization, instruments are frequently touched. There is a lack of standards relating to hand hygiene frequency and use of gloves in the sterilizing service unit packing area. To determine the effect of hand hygiene and glove use on maintenance of RSI cleanliness. Following manual and automated cleaning, Halsted-mosquito forceps were assessed for adenosine triphosphate (ATP), protein and microbial contamination after handling with gloved and ungloved but washed hands using an ATP surface swab test, bicinchoninic acid assay, and standard culture plate/broth, respectively. Gram's stain was used to classify the isolates. RSI contamination was assessed immediately following and 1, 2, and 4 h after washing hands. Packing instruments with hands that had been unwashed for 2 or 4 h resulted in a significant increase in contaminating ATP when compared with all other treatment groups (P < 0.05). There was a significant correlation between the time since washing hands, the amount of ATP (r = 0.93; P ≤ 0.001), and the microbial load (r = 0.83; P ≤ 0.001) contaminating the forceps, where the longer the time the hands remained unwashed the higher the contamination. Significantly more contaminating protein was found on forceps handled with ungloved hands that had not been washed for 2 or 4 h (P < 0.001). Critical RSI inspection, assembling, lubricating and packing should be performed using either gloves or within 1 h of washing hands. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Cleanliness audit of clinical surfaces and equipment: who cleans what?

    PubMed

    Anderson, R E; Young, V; Stewart, M; Robertson, C; Dancer, S J

    2011-07-01

    Current guidelines recommend regular cleaning of clinical equipment. We monitored items on a surgical ward for predominant user, hand-touch frequency, cleaning responsibilities and measurement of organic soil. Equipment was assessed in triplicate against a cleanliness benchmark of 100 relative light units (RLU) using the Hygiena® ATP system. There were 44 items, of which 21 were cleaned by clinical support workers (CSWs), five by domestic staff; three by nurses, three by doctors, and 12 with no designated cleaning responsibility. Geometric mean RLUs ranged from 60 to 550/100 cm² for small items such as hand-gel containers, bed control, blood pressure cuff and clinical notes; with similar values of 80-540/100 cm² RLU for larger items such as electrocardiogram machine, defibrillator, trolleys and tables. Overall geometric mean was 249/100 cm² RLU for all surfaces, with 84% (37 of 44) items exceeding the 100RLU benchmark. Of 27 items cleaned by clinical staff, 24 (89%) failed the benchmark. Of 12 sites with no cleaning specification, 11 (92%) failed the benchmark. Three of seven 'clean' sites (<100/100 cm² RLU) were cleaned by domestic staff. Average log(10) RLU of surfaces cleaned by domestics were 64% lower compared with surfaces cleaned by CSWs (95% confidence interval: 35%, 80%; P=0.019). In conclusion, clinical equipment frequently demonstrates high levels of organic soil, whether or not items have assigned cleaning responsibility. These findings suggest that cleaning practices for clinical equipment may require review, along with education of staff with specific cleaning responsibilities. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. Effects of different sonic activation protocols on debridement efficacy in teeth with single-rooted canals

    PubMed Central

    Niu, Li-na; Luo, Xiao-juan; Li, Guo-hua; Bortoluzzi, Eduardo A.; Mao, Jing; Chen, Ji-hua; Gutmann, James L.; Pashley, David H.; Tay, Franklin R.

    2014-01-01

    Objectives The effects of different EndoActivator® (EA) sonic activation protocols on root canal debridement efficacy were examined. Methods Root canals in 48 single-rooted teeth were instrumented, irrigated initially with NaOCl and divided into 6 groups (N=8) based on the application time of QMix (antimicrobial calcium-chelating irrigant), and the time and sequence of EA irrigant activation - Positive Control: 90 sec QMix; Negative Control: 90 sec saline; Group 1A: 15 sec QMix + 15 sec QMix with EA-activation; Group 1B: 30 sec QMix + 30 sec of QMix with EA-activation; Group 2A: 15 sec QMix with EA-activation + 15 sec QMix; Group 2B: 30 sec QMix with EA-activation + 30 sec QMix. Split roots were examined with scanning electron microscopy for assignment of smear and debris scores in locations along the coronal, middle and apical thirds of the canals. The overall cleanliness of pooled canal locations in the Positive Control and the 4 experimental groups were compared with chi-square tests. Results Significant differences were detected among the 5 groups (p<0.001). Post-hoc pairwise comparisons indicated that the overall canal cleanliness was in the order (from best to worst): 1B = 2B > 2A > 1A > Positive Control. Completely clean canals could not be achieved due to the absence of continuous irrigant flow for EA to clear intraradicular debris. Conclusions Irrespective of the sonic activation sequence, irrigant activation for 30 seconds during a 60-second period of QMix application appears to maximize the smear layer and debris removal potential of the EndoActivator® system. PMID:24878251

  13. Predictors of Women's Satisfaction with Hospital-Based Intrapartum Care in Asmara Public Hospitals, Eritrea.

    PubMed

    Kifle, Meron Mehari; Ghirmai, Filmon Abraham; Berhe, Soliana Amanuel; Tesfay, Winta Sium; Weldegebriel, Yodit Teklemariam; Gebrehiwet, Zebib Tesfamariam

    2017-01-01

    Exploring patient satisfaction contributes to provide quality maternity care, but there is paucity of epidemiologic data in Eritrea. To determine the predictors of women's satisfaction with intrapartum care in Asmara public maternity hospitals in Eritrea. A cross-sectional study among 771 mothers who gave birth in three public Hospitals. Chi-square tests were done to analyze the difference in proportion and logistic regression to assess the predictors of satisfaction with intrapartum care. Overall, only 20.8% of the participants were satisfied with intrapartum service. The key predictors of satisfaction with intrapartum care were provision of clean bed and beddings (AOR = 18.87, 2.33-15.75), privacy during examinations (AOR = 10.22, 4.86-21.48), using understandable language (AOR = 8.72, 3.57-21.27), showing how to summon for help (AOR = 8.16, 4.30-15.48), showing baby immediately after birth (AOR = 8.14, 2.87-23.07), control of the delivery room (AOR = 6.86, 2.65-17.75), receiving back massage (AOR = 6.43, 3.23-12.81), toilet access and cleanliness (AOR = 6.09, 3.25-11.42), availability of chairs for relatives (AOR = 5.96, 3.14-11.30), allowing parents to stay during labour (AOR = 3.52, 1.299-9.56), and request for permission before any procedure (AOR = 2.39, 1.28-4.46). To increase satisfaction with intrapartum care, maternity service providers need to address the general maternity ward cleanliness, improve the quality of physical facilities, and sensitize health providers for better communication with clients. Policy makers need to adopt strategies that ensure more women involvement in decision making and consideration of privacy and reassurance needs during the whole delivery process.

  14. Application of simplified bioclean apparatuses for treatment of acute leukemia.

    PubMed

    Hasegawa, H; Horiuchi, A

    1983-01-01

    We used a portable horizontal laminar-air-flow clean bed and an open horizontal laminar-air-flow fan (clean wall unit) for treating patients with acute leukemia. The level of cleanliness as shown in the nonviable and viable particle counts was class 100 and class 1,000 at the head and foot, respectively, of the bed in the clean-bed rooms, while it was class 100 and class 10,000 respectively, in the clean-wall-unit rooms. The level of cleanliness in the open wards, on the other hand, was class 1,000,000. The incidence of infectious complications in the clean-bed rooms was 3.1/100 days when the granulocyte count was 1,000/mm3 or less, 3.9/100 days when the count was 500/mm3 or less and 6.1/100 days when it was 100/mm3 or less. In the clean-wall-unit rooms, these values were 3.1, 3.7 and 7.1, respectively, while in the open wards they were 4.6, 6.1 and 15.0. Thus, it was ascertained that, as the granulocyte count decreased, the incidence of infectious complications became significantly higher in the open wards than in the clean-bed rooms or the clean-wall-unit rooms. No complication of pneumonia was found in 37 patients with acute leukemia in the clean-bed rooms or in 40 in the clean-wall-unit rooms. Among 36 patients treated in the open wards, on the other hand, the complication of pneumonia was found in four. From the above results, it is believed that the use of clean-bed rooms or clean-wall-unit rooms is an extremely effective supplementary treatment method for preventing respiratory tract infection complications in patients with acute leukemia.

  15. Cleanliness in the Root Canal System: An Scanning Electron Microscopic Evaluation of Manual and Automated Instrumentation using 4% Sodium Hypochlorite and EDTA (Glyde File Prep)―An in vitro Study

    PubMed Central

    Meshram, GK

    2010-01-01

    ABSTRACT Aim : To assess the cleaning efficacy of manual and automated instrumentation using 4% sodium hypochlorite singly and in combination with Glyde file Prep as root canal irrigant. Methodology : The study utilized 40 extracted human permanent premolars with single, straight and fully formed root. The teeth were then divided into four groups of ten each, Group I and II were prepared by manual instruments with 4% sodium hypochlorite used as irrigant singly [Group I] or in combination with Glyde file prep. Group III and IV were prepared by automated instruments at 250 rpm with 4% sodium hypochlorite as irrigant singly [Group III] and in combination with glyde file prep [Group IV] automated instrumentation. After completion of the root canal preparation the canal, teeth were prepared for SEM examination. These photomicrographs were qualitatively evaluated using criteria. Overall cleanliness, presence or absence of the smear layer, presence or absence of the debris, patency of the opening of dentinal tubules. Results : When comparing the cleansing efficacy of manual and automated instrumentation using 4% sodium hypochlorite better cleansing was there with manual instrumentation. When comparing the cleansing efficacy of manual and automated instrumentation using combination regime cleansing is better with automated instrumentation. When comparing the cleansing efficacy of manual instrumentation using 4% sodium hypochlorite singly and in combination with EDTA, the combination regime led to better cleansing. When comparing the cleansing efficacy of automated instrumentation using 4% sodium hypochlorite singly and in combination regime lead to better cleansing. Conclusion : Neither of instrumentation technique, nor irrigating regimes were capable of providing a completely clean canal. Automated instrumentation with a combination of sodium hypochlorite & EDTA resulted the best cleansing efficacy. PMID:27616839

  16. SEM Model Medical Solid Waste Hospital Management In Medan City

    NASA Astrophysics Data System (ADS)

    Simarmata, Verawaty; Pandia, Setiaty; Mawengkang, Herman

    2018-01-01

    In daily activities, hospitals, as one of the important health care unit, generate both medical solid waste and non-medical solid waste. The occurrence of medical solid waste could be from the results of treatment activities, such as, in the treatment room for a hospital inpatient, general clinic, a dental clinic, a mother and child clinic, laboratories and pharmacies. Most of the medical solid waste contains infectious and hazardous materials. Therefore it should be managed properly, otherwise it could be a source of new infectious for the community around the hospital as well as for health workers themselves. Efforts surveillance of various environmental factors need to be applied in accordance with the principles of sanitation focuses on environmental cleanliness. One of the efforts that need to be done in improving the quality of the environment is to undertake waste management activities, because with proper waste management is the most important in order to achieve an optimal degree of human health. Health development in Indonesian aims to achieve a future in which the Indonesian people live in a healthy environment, its people behave clean and healthy, able to reach quality health services, fair and equitable, so as to have optimal health status, health development paradigm anchored to the healthy. The healthy condition of the individual and society can be influenced by the environment. Poor environmental quality is a cause of various health problems. Efforts surveillance of various environmental factors need to be applied in accordance with the principles of sanitation focuses on environmental cleanliness. This paper proposes a model for managing the medical solid waste in hospitals in Medan city, in order to create healthy environment around hospitals.

  17. Characterization of TiN, TiC and Ti(C,N) in titanium-alloyed ferritic chromium steels focusing on the significance of different particle morphologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michelic, S.K., E-mail: susanne.michelic@unileoben.ac.at; Loder, D.; Reip, T.

    2015-02-15

    Titanium-alloyed ferritic chromium steels are a competitive option to classical austenitic stainless steels owing to their similar corrosion resistance. The addition of titanium significantly influences their final steel cleanliness. The present contribution focuses on the detailed metallographic characterization of titanium nitrides, titanium carbides and titanium carbonitrides with regard to their size, morphology and composition. The methods used are manual and automated Scanning Electron Microscopy with Energy Dispersive X-ray Spectroscopy as well as optical microscopy. Additional thermodynamic calculations are performed to explain the precipitation procedure of the analyzed titanium nitrides. The analyses showed that homogeneous nucleation is decisive at an earlymore » process stage after the addition of titanium. Heterogeneous nucleation gets crucial with ongoing process time and essentially influences the final inclusion size of titanium nitrides. A detailed investigation of the nuclei for heterogeneous nucleation with automated Scanning Electron Microscopy proved to be difficult due to their small size. Manual Scanning Electron Microscopy and optical microscopy have to be applied. Furthermore, it was found that during solidification an additional layer around an existing titanium nitride can be formed which changes the final inclusion morphology significantly. These layers are also characterized in detail. Based on these different inclusion morphologies, in combination with thermodynamic results, tendencies regarding the formation and modification time of titanium containing inclusions in ferritic chromium steels are derived. - Graphical abstract: Display Omitted - Highlights: • The formation and modification of TiN in the steel 1.4520 was examined. • Heterogeneous nucleation essentially influences the final steel cleanliness. • In most cases heterogeneous nuclei in TiN inclusions are magnesium based. • Particle morphology provides important information on inclusion formation.« less

  18. MOPITT Mechanisms 16 Years In-Orbit Operation on TERRA

    NASA Technical Reports Server (NTRS)

    Gibson, Andrew S.; Nichitiu, Florian; Caldwell, Dwight

    2016-01-01

    The 16th anniversary of the launch of NASA's Terra Spacecraft was marked on December 18, 2015, with the Measurements of Pollution in the Troposphere (MOPITT) instrument being a successful contributor to the NASA EOS flagship. MOPITT has been enabled by a large suite of mechanisms, allowing the instrument to perform long-duration monitoring of atmospheric carbon monoxide, providing global measurements of this important greenhouse gas for 16 years. Mechanisms have been successfully employed for scanning, cooling of detectors, and to optically modulate the gas path length within the instrument by means of pressure and gas cell length variation. The instrument utilizes these devices to perform correlation spectroscopy, enabling measurements with vertical resolution from the nadir view, and has thereby furthered understanding of source and global transport effects of carbon monoxide. Given the design requirement for a 5.25-year lifetime, the stability and performance of the majority of mechanisms have far surpassed design goals. With 16 continuously operating mechanisms in service on MOPITT, including 12 rotating mechanisms and 4 with linear drive elements, the instrument was an ambitious undertaking. The long life requirements combined with demands for cleanliness and optical stability made for difficult design choices including that of the selection of new lubrication processes. Observations and lessons learned with regards to many aspects of the mechanisms and associated monitoring devices are discussed here. Mechanism behaviors are described, including anomalies, long-term drive current/power, fill pressure, vibration and cold-tip temperature trends. The effectiveness of particular lubrication formulations and the screening method implemented is discussed in relation to continuous rotating mechanisms and stepper motors, which have exceeded 15 billon rotations and 2.5 billion steps respectively. Aspects of gas cell hermeticity, optical cleanliness, heater problems and SEU effects on accelerometers are also discussed.

  19. Precision Determination of Adsorption Layers on Stainless Steel Mass Standards by Mass Comparison and Ellipsometry: Part I: Adsorption Isotherms in Air

    NASA Astrophysics Data System (ADS)

    Schwartz, R.

    1994-01-01

    Adsorption layers on stainless steel mass standards (OIML classes E1 and E2) have been determined directly and precisely by the optical method of ellipsometry as a function of relative humidity in the range 0,03 <= h <= 0,77, the relevant influencing factors being surface cleanliness, roughness, steel composition and ambient temperature. Under the same environmental conditions, two pairs of 1 kg artefacts, having geometrical surfaces differing in area by about δ A = 390 cm2, but the same material properties and surface finish as the mass standards, have been compared on a 1 kg mass comparator. The two independent measuring techniques yield strongly correlated results, the standard uncertainties of the measured surface coverings being = 0,7 μg cm-2 show sorption-induced mass variations which are greater by about a factor of 2,5 relative to the clean surfaces.

  20. Effect of Minerals on Intestinal IgA Production Using Deep Sea Water Drinks.

    PubMed

    Shiraishi, Hisashi; Fujino, Maho; Shirakawa, Naoki; Ishida, Nanao; Funato, Hiroki; Hirata, Ayumu; Abe, Noriaki; Iizuka, Michiro; Jobu, Kohei; Yokota, Junko; Miyamura, Mitsuhiko

    2017-01-01

    Minerals are essential for life, as they are a vital part of protein constituents, enzyme cofactors, and other components in living organisms. Deep sea water is characterized by its cleanliness and stable low temperature, and its possible health- and medical benefits are being studied. However, no study has yet evaluated the physical properties of the numerous commercially available deep sea water products, which have varying water sources and production methods. We analyzed these products' mineral content and investigated their effect on living organism, focusing on immune functions, and investigated the relation between physiological immunoactivities and mineral intake. We qualitatively analyzed the mineral compositions of the deep sea water drinks and evaluated the drinks' physical properties using principal component analysis, a type of multivariate analysis, of their mineral content. We create an iron and copper-deficient rat model and administered deep sea water drinks for 8 weeks. We then measured their fecal immunoglobulin A (IgA) to evaluate immune function. Principal component analysis suggested that physical properties of deep sea water drinks could be determined by their sources. Administration of deep sea water drinks increased fecal IgA, thus tending to stimulate immune function, but the extent of this effect varied by drink. Of the minerals contained in deep sea water, iron showed positive correlations with the fecal IgA. The principal component analysis used in this study is suitable for evaluating deep sea water containing many minerals, and our results form a useful basis for comparative evaluations of deep sea water's bioactivity.

  1. Data and Tools | Energy Analysis | NREL

    Science.gov Websites

    and Tools Energy Analysis Data and Tools NREL develops energy analysis data and tools to assess collections. Data Products Technology and Performance Analysis Tools Energy Systems Analysis Tools Economic and Financial Analysis Tools

  2. Minimization of nanosatellite low frequency magnetic fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belyayev, S. M., E-mail: belyayev@isr.lviv.ua; Royal Institute of Technology, Stockholm 11428; Dudkin, F. L.

    2016-03-15

    Small weight and dimensions of the micro- and nanosatellites constrain researchers to place electromagnetic sensors on short booms or on the satellite body. Therefore the electromagnetic cleanliness of such satellites becomes a central question. This paper describes the theoretical base and practical techniques for determining the parameters of DC and very low frequency magnetic interference sources. One of such sources is satellite magnetization, the reduction of which improves the accuracy and stability of the attitude control system. We present design solutions for magnetically clean spacecraft, testing equipment, and technology for magnetic moment measurements, which are more convenient, efficient, and accuratemore » than the conventional ones.« less

  3. Role of environmental cleanliness and decontamination in care homes.

    PubMed

    Cousins, Gary

    2016-01-06

    While it is widely accepted that the environment has an important role in transmission of healthcare-associated infections, there has been a paucity of empirical investigation in this area to date, and the majority of published literature relates to acute settings. People living in care homes come into contact with a communally used environment and communally used equipment daily. Equipment may include hoists, hoist slings, clinical monitoring equipment, commodes and shower chairs. In care homes, primary responsibility for decontamination lies with the healthcare team, most of whom are not nurses. The challenge for nurses working in care homes is their accountability for the provision of safe and effective care.

  4. A polytetrafluorethylene insulated cable for high temperature oxygen aerospace applications

    NASA Technical Reports Server (NTRS)

    Sheppard, A. T.; Webber, R. G.

    1983-01-01

    For electrical cables to function and survive in the severe high temperature oxygen environment that will be experienced in the external tanks of the space shuttle, extreme cleanliness and material purity is required. A flexible light weight cable has been developed for use in pure oxygen at worst case temperatures of -190 to +260 degrees Centigrade and pressures as high as 44 pounds per square inch absolute. A comprehensive series of tests were performed on cables manufactured to the best commercial practices in order to establish the basic guidelines for control of build configuration as well as each material used in construction of the cable.

  5. Anomalously high potentials observed on ISEE

    NASA Technical Reports Server (NTRS)

    Whipple, E. C.; Krinsky, I. S.; Torbert, R. B.; Olsen, R. C.

    1985-01-01

    Data from two electric field experiments and from the plasma composition experiment on ISEE-1 are used to show that the spacecraft charged to close to -70 V in sunlight at 0700 UT on March 17, 1978. Data from the electron spectrometer experiment show that there was a potential barrier of -10 to -20 V about the spacecraft during this event. The potential barrier was effective in turning back emitted photoelectrons to the spacecraft. The stringent electrostatic cleanliness specifications imposed on ISEE make the presence of differential charging unlikely. Modeling of this event is required to determine if the barrier was produced by the presence of space charge.

  6. Psychiatric disorders related to menstrual bleeding among an ultra-orthodox population: case series and literature review.

    PubMed

    Vishne, Tali; Misgav, Sagit; Bunzel, Michael E

    2008-05-01

    The relationship between menstrual cycle and obsessive-compulsive disorder (OCD) has been documented in the past and is related to sexual hormone changes. In the ultra-orthodox Jewish population menstrual bleeding is associated both with meticulous rituals of cleanliness and with stressful meanings related to sin, impurity and punishment. Those aspects of the menstrual cycle can be related to specific OCD symptoms among ultra-orthodox women. The current study presents three cases related to the development of obsessive-compulsive symptoms in relation to the menstrual cycle among ultra-orthodox women, and discusses the biological and social-cultural basis of the disorder.

  7. THE INTERNATIONAL IMPLICATIONS OF QUALITY-OF-LIFE POLICING AS PRACTICED IN NEW YORK CITY

    PubMed Central

    Johnson, Bruce D.; Golub, Andrew; McCabe, James

    2008-01-01

    The New York City Police Department (NYPD) has made enforcement of laws against disorder and quality-of-life offenses a central part of their policing strategy. Concomitantly, New York City (NYC) experienced a renaissance in orderliness, cleanliness, tourism, real estate value, and crime reduction, although other problems such as poverty, unemployment, drug abuse, racial tensions and homelessness persist. This paper examines quality-of-life policing practices in NYC, describes the philosophical underpinnings, explores the critical response to the program and presents lessons of potential relevance to other policing organizations in the U.S. and around the world. PMID:20368765

  8. Organic Contamination Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

    NASA Technical Reports Server (NTRS)

    Calaway, Michael J.; Allton, J. H.; Allen, C. C.; Burkett, P. J.

    2013-01-01

    Future planned sample return missions to carbon-rich asteroids and Mars in the next two decades will require strict handling and curation protocols as well as new procedures for reducing organic contamination. After the Apollo program, astromaterial collections have mainly been concerned with inorganic contamination [1-4]. However, future isolation containment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs.

  9. Cavity Preparation/assembly Techniques and Impact on Q, Realistic Q - Factors in a Module, Review of Modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peter Kneisel

    2005-03-19

    This contribution summarizes the surface preparation procedures for niobium cavities presently used both in laboratory experiments and for modules, such as buffered chemical polishing (BCP), electropolishing (EP), high pressure ultrapure water rinsing (HPR), CO{sub 2} snow cleaning and high temperature heat treatments for hydrogen degassing or postpurification. The impact of surface treatments and the degree of cleanliness during assembly procedures on cavity performance (Q - value and accelerating gradient E{sub acc}) will be discussed. In addition, an attempt will be made to summarize the experiences made in module assemblies in different labs/projects such as DESY(TTF), Jlab (Upgrade) and SNS.

  10. Visual Inspection of Surfaces

    NASA Technical Reports Server (NTRS)

    Hughes, David; Perez, Xavier

    2007-01-01

    This presentation evaluates the parameters that affect visual inspection of cleanliness. Factors tested include surface reflectance, surface roughness, size of the largest particle, exposure time, inspector and distance from sample surface. It is concluded that distance predictions were not great, particularly because the distance at which contamination is seen may depend on more variables than those tested. Most parameters estimates had confidence of 95% or better, except for exposure and reflectance. Additionally, the distance at which surface is visibly contaminated decreases with increasing reflectance, roughness, and exposure. The distance at which the surface is visually contaminated increased with the largest particle size. These variables were only slightly affected the observer.

  11. A polytetrafluorethylene insulated cable for high temperature oxygen aerospace applications

    NASA Astrophysics Data System (ADS)

    Sheppard, A. T.; Webber, R. G.

    For electrical cables to function and survive in the severe high temperature oxygen environment that will be experienced in the external tanks of the space shuttle, extreme cleanliness and material purity is required. A flexible light weight cable has been developed for use in pure oxygen at worst case temperatures of -190 to +260 degrees Centigrade and pressures as high as 44 pounds per square inch absolute. A comprehensive series of tests were performed on cables manufactured to the best commercial practices in order to establish the basic guidelines for control of build configuration as well as each material used in construction of the cable.

  12. Superacid Passivation of Crystalline Silicon Surfaces.

    PubMed

    Bullock, James; Kiriya, Daisuke; Grant, Nicholas; Azcatl, Angelica; Hettick, Mark; Kho, Teng; Phang, Pheng; Sio, Hang C; Yan, Di; Macdonald, Daniel; Quevedo-Lopez, Manuel A; Wallace, Robert M; Cuevas, Andres; Javey, Ali

    2016-09-14

    The reduction of parasitic recombination processes commonly occurring within the silicon crystal and at its surfaces is of primary importance in crystalline silicon devices, particularly in photovoltaics. Here we explore a simple, room temperature treatment, involving a nonaqueous solution of the superacid bis(trifluoromethane)sulfonimide, to temporarily deactivate recombination centers at the surface. We show that this treatment leads to a significant enhancement in optoelectronic properties of the silicon wafer, attaining a level of surface passivation in line with state-of-the-art dielectric passivation films. Finally, we demonstrate its advantage as a bulk lifetime and process cleanliness monitor, establishing its compatibility with large area photoluminescence imaging in the process.

  13. Characterization of Inclusion Populations in Mn-Si Deoxidized Steel

    NASA Astrophysics Data System (ADS)

    García-Carbajal, Alfonso; Herrera-Trejo, Martín; Castro-Cedeño, Edgar-Ivan; Castro-Román, Manuel; Martinez-Enriquez, Arturo-Isaias

    2017-12-01

    Four plant heats of Mn-Si deoxidized steel were conducted to follow the evolution of the inclusion population through ladle furnace (LF) treatment and subsequent vacuum treatment (VT). The liquid steel was sampled, and the chemical composition and size distribution of the inclusion populations were characterized. The Gumbel generalized extreme-value (GEV) and generalized Pareto (GP) distributions were used for the statistical analysis of the inclusion size distributions. The inclusions found at the beginning of the LF treatment were mostly fully liquid SiO2-Al2O3-MnO inclusions, which then evolved into fully liquid SiO2-Al2O3-CaO-MgO and partly liquid SiO2-CaO-MgO-(Al2O3-MgO) inclusions detected at the end of the VT. The final fully liquid inclusions had a desirable chemical composition for plastic behavior in subsequent metallurgical operations. The GP distribution was found to be undesirable for statistical analysis. The GEV distribution approach led to shape parameter values different from the zero value hypothesized from the Gumbel distribution. According to the GEV approach, some of the final inclusion size distributions had statistically significant differences, whereas the Gumbel approach predicted no statistically significant differences. The heats were organized according to indicators of inclusion cleanliness and a statistical comparison of the size distributions.

  14. Biomass Briquette Investigation from Pterocarpus Indicus Leaves Waste as an Alternative Renewable Energy

    NASA Astrophysics Data System (ADS)

    Anggono, Willyanto; Sutrisno; Suprianto, Fandi D.; Evander, Jovian

    2017-10-01

    Indonesia is a tropical country located in Southeast Asia. Indonesia has a lot of variety of plant species which are very useful for life. Pterocarpus indicus are commonly used as greening and easily found everywhere in Surabaya city because of its characteristics that they have dense leaves and rapid growth. Pterocarpus indicus leaves waste would be a problem for residents of Surabaya and disturbing the cleanliness of the Surabaya city. Therefore, the Pterocarpus indicus leaves waste would be used as biomass briquettes. This research investigated the calorific value of biomass briquettes from the Pterocarpus indicus leaves waste, the effect of tapioca as an adhesive material to the calorific value of biomass briquettes from the Pterocarpus indicus leaves waste, the optimum composition for Pterocarpus indicus leaves waste biomass briquette as an alternative renewable fuel and the property of the optimum resulted biomass briquette using ultimate analysis and proximate analysis based on the ASTM standard. The calorific value biomass briquettes from the Pterocarpus indicus leaves waste were performed using an oxygen bomb calorimeter at various composition of Pterocarpus indicus from 50% to 90% rising by 10% for each experiment. The experimental results showed that the 90% raw materials (Pterocarpus indicus leaves waste)-10% adhesive materials (tapioca) mixtures is the optimum composition for biomass briquette Pterocarpus indicus leaves waste. The lower the percentage of the mass of tapioca in the biomass briquettes, the higher calorific value generated.

  15. Batch and Continuous Ultrasound Assisted Extraction of Boldo Leaves (Peumus boldus Mol.).

    PubMed

    Petigny, Loïc; Périno-Issartier, Sandrine; Wajsman, Joël; Chemat, Farid

    2013-03-12

    Vegetal extracts are widely used as primary ingredients for various products from creams to perfumes in the pharmaceutical, nutraceutic and cosmetic industries. Having concentrated and active extract is essential, as the process must extract as much soluble material as possible in a minimum time, using the least possible volume of solvent. The boldo leaves extract is of great interest for the industry as it holds a great anti-oxidant activity due to high levels of flavonoids and alkaloids such as boldine. Ultrasound Assisted Extraction (UAE) has been used to improve the efficiency of the plant extraction, reducing extraction time, increasing the concentration of the extract with the same amount of solvent and plant material. After a preliminary study, a response surface method has been used to optimize the extraction of soluble material from the plant. The results provided by the statistical analysis revealed that the optimized conditions were: sonication power 23 W/cm2 for 40 min and a temperature of 36 °C. The optimized parameters of the UAE provide a better extraction compared to a conventional maceration in terms of process time (30 min instead of 120 min), higher yield, more energy saving, cleanliness, safety and product quality.

  16. Batch and Continuous Ultrasound Assisted Extraction of Boldo Leaves (Peumus boldus Mol.)

    PubMed Central

    Petigny, Loïc; Périno-Issartier, Sandrine; Wajsman, Joël; Chemat, Farid

    2013-01-01

    Vegetal extracts are widely used as primary ingredients for various products from creams to perfumes in the pharmaceutical, nutraceutic and cosmetic industries. Having concentrated and active extract is essential, as the process must extract as much soluble material as possible in a minimum time, using the least possible volume of solvent. The boldo leaves extract is of great interest for the industry as it holds a great anti-oxidant activity due to high levels of flavonoids and alkaloids such as boldine. Ultrasound Assisted Extraction (UAE) has been used to improve the efficiency of the plant extraction, reducing extraction time, increasing the concentration of the extract with the same amount of solvent and plant material. After a preliminary study, a response surface method has been used to optimize the extraction of soluble material from the plant. The results provided by the statistical analysis revealed that the optimized conditions were: sonication power 23 W/cm2 for 40 min and a temperature of 36 °C. The optimized parameters of the UAE provide a better extraction compared to a conventional maceration in terms of process time (30 min instead of 120 min), higher yield, more energy saving, cleanliness, safety and product quality. PMID:23481637

  17. Vaginal douching practice: Frequency, associated factors and relationship with vulvovaginal symptoms.

    PubMed

    Yanikkerem, Emre; Yasayan, Aysegul

    2016-04-01

    To determine the frequency, associated factors and relationship with vulvovaginal symptoms and vaginal douching among Turkish women. The cross-sectional, analytical study was conducted at Merkez Efendi Hospital, Manisa, Turkey, from January to June 2014 using a questionnaire. Statistical analysis was carried out using SPSS 17. Of the total 343 women in the study, 91(26.5%) had reported vaginal douching in the preceding year. Statistically significant relationship was determined between the vaginal douching behaviour and couples who had low educationand low income levels, having unplanned pregnancy and had someone in their neighbourhood who douched (p< 0.05 each). The most common reason for using vaginal douching was reported to be cleanliness by 85(93.4%) women, prevention of genital infections 75(82.4%), cleaning after/before sexual intercourse 72(79%), during menstruation 49(54%), prevention of vaginal discharge 69(76%), decreasing of unpleasant odours 65(71.4%) and religious beliefs 46(50.5%). Self-reported history of vaginal infection was significantly more common for women who douched compared those who did not (p< 0.05). Healthcare providers should determine the reason and risky groups of women and educate the women to stop the vaginal douching behaviour and harmful effects of vaginal douching.

  18. What Orthopaedic Operating Room Surfaces Are Contaminated With Bioburden? A Study Using the ATP Bioluminescence Assay.

    PubMed

    Richard, Raveesh Daniel; Bowen, Thomas R

    2017-07-01

    Contaminated operating room surfaces can increase the risk of orthopaedic infections, particularly after procedures in which hardware implantation and instrumentation are used. The question arises as to how surgeons can measure surface cleanliness to detect increased levels of bioburden. This study aims to highlight the utility of adenosine triphosphate (ATP) bioluminescence technology as a novel technique in detecting the degree of contamination within the sterile operating room environment. What orthopaedic operating room surfaces are contaminated with bioburden? When energy is required for cellular work, ATP breaks down into adenosine biphosphate (ADP) and phosphate (P) and in that process releases energy. This process is inherent to all living things and can be detected as light emission with the use of bioluminescence assays. On a given day, six different orthopaedic surgery operating rooms (two adult reconstruction, two trauma, two spine) were tested before surgery with an ATP bioluminescence assay kit. All of the cases were considered clean surgery without infection, and this included the previously performed cases in each sampled room. These rooms had been cleaned and prepped for surgery but the patients had not been physically brought into the room. A total of 13 different surfaces were sampled once in each room: the operating room (OR) preparation table (both pre- and postdraping), OR light handles, Bovie machine buttons, supply closet countertops, the inside of the Bair Hugger™ hose, Bair Hugger™ buttons, right side of the OR table headboard, tourniquet machine buttons, the Clark-socket attachment, and patient positioners used for total hip and spine positioning. The relative light units (RLUs) obtained from each sample were recorded and data were compiled and averaged for analysis. These values were compared with previously published ATP benchmark values of 250 to 500 RLUs to define cleanliness in both the hospital and restaurant industries. All surfaces had bioburden. The ATP RLUs (mean ± SD) are reported for each surface in ascending order: the OR preparation table (postdraping; 8.3 ± 3.4), inside the sterilized pan (9.2 ± 5.5), the inside of the Bair Hugger™ hose (212.5 ± 155.7), supply closet countertops (281.7 ± 236.7), OR light handles (647.8 ± 903.7), the OR preparation table (predraping; 1054 ± 387.5), the Clark-socket attachment (1135.7 ± 705.3), patient positioners used for total hip and spine positioning (1201.7 ± 1144.9), Bovie machine buttons (1264.5 ± 638.8), Bair Hugger™ buttons (1340.8 ± 1064.1), tourniquet machine buttons (1666.5 ± 2144.9), computer keyboard (1810.8 ± 929.6), and the right side of the OR table headboard (2539 ± 5635.8). ATP bioluminescence is a novel method to measure cleanliness within the orthopaedic OR and can help identify environmental trouble spots that can potentially lead to increased infection rates. Future studies correlating ATP bioluminescence findings with microbiology cultures could add to the clinical utility of this technology. Surfaces such as the undersurface of the OR table headboard, Bair Hugger™ buttons, and tourniquet machine buttons should be routinely cleansed as part of an institutional protocol. Although correlation between ATP bioluminescence and clinical infection was not evaluated in this study, it is the subject of future research. Specifically, evaluating microbiology samples taken from these environmental surfaces and correlating them with increased bioburden found with ATP bioluminescence technology can help promote improved surgical cleaning practices.

  19. Surgical instrument biocontaminant fluorescence detection in ambient lighting conditions for hospital reprocessing and sterilization department (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Baribeau, François; Bubel, Annie; Dumont, Guillaume; Vachon, Carl; Lépine, André; Rochefort, Stéphane; Massicotte, Martin; Buteau-Vaillancourt, Louis; Gallant, Pascal; Mermut, Ozzy

    2017-03-01

    Hospitals currently rely on simple human visual inspection for assessing cleanliness of surgical instruments. Studies showed that surgical site infections are in part attributed to inadequate cleaning of medical devices. Standards groups recognize the need to objectively quantify the amount of residues on surgical instruments and establish guidelines. We developed a portable technology for the detection of contaminants on surgical instruments through fluorescence following cleaning. Weak fluorescence signals are usually detected in the obscurity only with the lighting of the excitation source. The key element of this system is that it works in ambient lighting conditions, a requirement to not disturb the normal workflow of hospital reprocessing facilities. A biocompatible fluorescent dye is added to the detergent and labels the proteins of organic residues. It is resistant to the harsh environment in a washer-disinfector. Two inspection devices have been developed with a 488nm laser as the excitation source: a handheld scanner and a tabletop station using spectral-domain and time-domain ambient light cancellation schemes. The systems are eye safe and equipped with image processing and interfacing software to provide visual or audible warnings to the operator based on a set of adjustable signal thresholds. Micron-scale residues are detected by the system which can also evaluate soil size and mass. Unlike swabbing, it can inspect whole tools in real-time. The technology has been validated in an independent hospital decontamination research laboratory. It also has potential applications in the forensics, agro-food, and space fields. Technical aspects and results will be presented and discussed.

  20. Can Hospital Cultural Competency Reduce Disparities in Patient Experiences with Care?

    PubMed Central

    Weech-Maldonado, Robert; Elliott, Marc N.; Pradhan, Rohit; Schiller, Cameron; Hall, Allyson; Hays, Ron D.

    2013-01-01

    Background Cultural competency has been espoused as an organizational strategy to reduce health disparities in care. Objective To examine the relationship between hospital cultural competency and inpatient experiences with care. Research Design The first model predicted Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) scores from hospital random effects, plus fixed effects for hospital cultural competency, individual race/ethnicity/language, and case-mix variables. The second model tested if the association between a hospital’s cultural competency and HCAHPS scores differed for minority and non-Hispanic white patients. Subjects The National CAHPS® Benchmarking Database’s (NCBD) HCAHPS Surveys and the Cultural Competency Assessment Tool of Hospitals (CCATH) Surveys for California hospitals were merged, resulting in 66 hospitals and 19,583 HCAHPS respondents in 2006. Measures Dependent variables include ten HCAHPS measures: six composites (communication with doctors, communication with nurses, staff responsiveness, pain control, communication about medications, and discharge information), two individual items (cleanliness, and quietness of patient rooms), and two global items (overall hospital rating, and whether patient would recommend hospital). Results Hospitals with greater cultural competency have better HCAHPS scores for doctor communication, hospital rating, and hospital recommendation. Furthermore, HCAHPS scores for minorities were higher at hospitals with greater cultural competency on four other dimensions: nurse communication, staff responsiveness, quiet room, and pain control. Conclusions Greater hospital cultural competency may improve overall patient experiences, but may particularly benefit minorities in their interactions with nurses and hospital staff. Such effort may not only serve longstanding goals of reducing racial/ethnic disparities in inpatient experience, but may also contribute to general quality improvement. PMID:23064277

Top