Food and Food-Odor Preferences in Dogs: A Pilot Study
Péron, Franck; Cambou, Stéphanie; Callejon, Laurence; Wynne, Clive D.L.
2017-01-01
Abstract Evaluation of food palatability and preference is of great importance to the pet food industry. One common technique for evaluating palatability is a 2-bowl test in which 2 products are offered simultaneously and food consumption is measured. This yields clear results with dogs trained to routinely conduct such comparisons, but it is less clear how this extends to untrained pet dogs. In addition, prior research indicates that olfaction is important in food preference, but methods for evaluating odor preference in canines are currently lacking. In this study, we developed a modified 2-bowl test for evaluation of food preferences in pet dogs with minimal training, and an olfactometer technique for the evaluation of odor preferences. In our 2-bowl procedure, we observed clear preferences among 4 commercial food products in 6 pet dogs. Across repeated testing, preferences strengthened, but the first evaluation accurately estimated the direction and significance of preference. In addition, dogs typically (89% of the time) consumed more of the food they chose first, suggesting they did not need to taste each food to choose. Our odor preference olfactometer assessment, however, did not reveal odor preferences other than that dogs preferred to sniff a food odor over clean air. Further work will be needed to identify methods of measuring odor preferences amongst food odors for dogs, but the modified 2-bowl test shows promise for further testing in pet dogs.
NEMA NU 4-2008 comparison of preclinical PET imaging systems.
Goertzen, Andrew L; Bao, Qinan; Bergeron, Mélanie; Blankemeyer, Eric; Blinder, Stephan; Cañadas, Mario; Chatziioannou, Arion F; Dinelle, Katherine; Elhami, Esmat; Jans, Hans-Sonke; Lage, Eduardo; Lecomte, Roger; Sossi, Vesna; Surti, Suleman; Tai, Yuan-Chuan; Vaquero, Juan José; Vicente, Esther; Williams, Darin A; Laforest, Richard
2012-08-01
The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: microPET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand.
NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems
Goertzen, Andrew L.; Bao, Qinan; Bergeron, Mélanie; Blankemeyer, Eric; Blinder, Stephan; Cañadas, Mario; Chatziioannou, Arion F.; Dinelle, Katherine; Elhami, Esmat; Jans, Hans-Sonke; Lage, Eduardo; Lecomte, Roger; Sossi, Vesna; Surti, Suleman; Tai, Yuan-Chuan; Vaquero, Juan José; Vicente, Esther; Williams, Darin A.; Laforest, Richard
2014-01-01
The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. Methods We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: micro- PET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. Results The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. Conclusion Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand. PMID:22699999
NASA Astrophysics Data System (ADS)
Canadas, Mario; Embid, Miguel; Lage, Eduardo; Desco, Manuel; Vaquero, Juan José; Perez, José Manuel
2011-02-01
In this work, we compare two commercial positron emission tomography (PET) scanners installed at CIEMAT (Madrid, Spain): the ClearPET and the rPET-1. These systems have significant geometrical differences, such as the axial field of view (110 mm on ClearPET versus 45.6 mm on rPET-1), the configuration of the detectors (whole ring on ClearPET versus one pair of planar blocks on rPET-1) and the use of an axial shift between ClearPET detector modules. We used an assessment procedure that fulfilled the recommendations of the National Electrical Manufacturers Association (NEMA) NU 4-2008 standard. The methodology includes studies of spatial resolution, sensitivity, scatter fraction, count losses and image quality. Our experiments showed a central spatial resolution of 1.5 mm (transaxial), 3.2 mm (axial) for the ClearPET and 1.5 mm (transaxial), 1.6 mm (axial) for the rPET-1, with a small variation across the transverse axis on both scanners ( 1 mm). The absolute sensitivity at the centre of the field of view was 4.7% for the ClearPET and 1.0% for the rPET-1. The peak noise equivalent counting rate for the mouse-sized phantom was 73.4 kcps reached at 0.51 MBq/mL on the ClearPET and 29.2 kcps at 1.35 MBq/mL on the rPET-1. The recovery coefficients measured using the image quality phantom ranged from 0.11 to 0.89 on the ClearPET and from 0.14 to 0.81 on the rPET-1. The overall performance shows that both the ClearPET and the rPET-1 systems are very suitable for preclinical research and imaging of small animals.
NASA Astrophysics Data System (ADS)
Yang, Zhao-Ping; Xin, Chun-Ling; Guo, Ya-Feng; Luo, Yi-Wei; He, Ya-Dong
2016-05-01
Improving the melt viscoelasticity of poly(ethylene terephthalate) (PET) is a well-known method to obtain foamable PET. The aim of this study is to prepare high melt strength PET and evaluate the influence of rheological properties of PET on the foaming behavior. For this purpose, pyromelliticdianhydride was used as the chain extender to modify a linear PET through melt reactive processing. The rheological properties of the unmodified and modified PETs were measured by a dynamic rheometer. Results showed that the modified PET had higher complex viscosity than the unmodified one. Furthermore, the batch foaming by using supercritical CO2 as a blowing agent was carried to evaluate the foamability of modified PETs. It was found that an enlarged foaming temperature window was obtained for modified PETs compared to unmodified PET. Moreover, the modified PETs foams exhibited higher expansion ratio, smaller cell size and higher cell density at high temperatures than the neat PET.
Preparation and dyeing of super hydrophilic polyethylene terephthalate fabric
NASA Astrophysics Data System (ADS)
Zheng, D. D.; Zhou, J. F.; Xu, F.; Zhang, F. X.; Zhang, G. X.
2016-07-01
In this study, the dyeing properties of PET fabrics modified with sulfuric acid was investigated using disperse red E-4B and disperse blue 2BLNG-L at high temperature and high pressure. The results revealed that the sulfuric acid modification improved the K/S value of dyeing PET fabrics, and the modified PET fabric could be dyed uniformly. The a, b, C, L and H of modified PET fabric were almost the same as that of original PET fabric. The water contact angles were still 0o after 10s, indicating that the hydrophilic property of modified PET fabrics still kept excellent. The wash fastness of dyed PET fabrics after modification was generally good.
NASA Astrophysics Data System (ADS)
Irena, Gancarz; Jolanta, Bryjak; Karolina, Zynek
2009-07-01
Poly(ethylene terephthalate) (PET) film was modified by reaction with hydrazine (HD), ethylenediamine (EDA), 1,2-diaminopropane (1,2-DAP) and 1,3-diaminopropane (1,3-DAP). The maximal amount of amine functionalities introduced in the chosen conditions on the surface was found as 0.07, 3.35, 0.76 and 1.99 nmol cm -2 for HD, EDA, 1,2-DAP and 1,3-DAP respectively. During the modification process etching of the sample and an increase of stiffness takes place. FTIR-ATR spectra prove that the surface chemistry after modification in amine solution is very complex. The lack of clear correlation between the surface tension and surface concentration of amine functionalities seems to confirm that. For immobilization purpose invertase, laccase and tyrosinase were used. The amount of covalently attached proteins at first increases with the increase of surface concentration of amine groups but after reaching a certain level of amine groups, decrease of the immobilization level was observed. All enzymes tested showed highest activity for a moderate level of aminolysis and this activity had the highest values for EDA-modified PET.
NASA Astrophysics Data System (ADS)
Jalali Dil, Ebrahim; Kim, Samuel C.; Saffar, Amir; Ajji, Abdellah; Zare, Richard N.; Sattayapiwat, Annie; Esguerra, Vanessa; Bowen, Raffick A. R.
2018-06-01
The surface chemistry and surface energy of chemically modified polyethylene terephthalate (PET) blood collection tubes (BCTs) were studied and the results showed a significant increase in hydrophilicity and polarity of modified PET surface. The surface modification created nanometer-sized, needle-like asperities through molecular segregation at the surface. The surface dynamics of the modified PET was examined by tracking its surface properties over a 280-day period. The results showed surface rearrangement toward a surface with lower surface energy and fewer nanometer-sized asperities. Thromboelastography (TEG) was used to evaluate and compare the thrombogenicity of the inner walls of various types of BCTs. The TEG tracings and data from various types of BCTs demonstrated differences in the reactionand coagulation times but not in clot strength. The performance of the modified tubes in free triiodothyronine (FT3) and free thyroxine (FT4) hormone tests was examined, and it was found that the interference of modified PET tubes was negligible compared to that of commercially available PET BCTs.
NASA Astrophysics Data System (ADS)
Yang, J.; Kim, K. B.; Choi, Y.; Kang, J.
2018-04-01
A depth-encoding positron emission tomography (PET) detector inserting a horizontal-striped glass between pixilated scintillation crystal layers was developed and experimentally evaluated. The detector consists of 2-layers of 4×4 LYSO array arranged with a 3.37 mm pitch. Horizontal-striped glasses with 1×4 array with different thickness of 3, 4 and 5 mm were inserted between top- and bottom-crystal layers. Bottom surface of bottom-layer was optically coupled to a 4×4 GAPD array. Sixteen output signals from DOI-PET detector were multiplexed by modified resistive charge division (RCD) networks and multiplexed signals were fed into custom-made charge-sensitive preamplifiers. The four amplified signals were digitized and recorded by the custom-made DAQ system based on FPGA. The four digitized outputs were post-processed and converted to flood histograms for each interaction event. Experimental results revealed that all crystal pixels were clearly identified on the 2D flood histogram without overlapping. Patterns of the 2D flood histogram were constituted with arrangements of [bottom–top–bottom–top–\\ldots–top–bottom–top–bottom] crystal responses in X-direction. These could be achieved by employing horizontal-striped glass that controlled the extent of light dispersion towards the X-direction in crystal layers for generation of a different position mapping for each layer and the modified RCD network that controls degree of charge sharing in readout electronics for reduction of identification error. This study demonstrated the proposed DOI-PET detector can extract the 3D γ-ray interaction position without considerable performance degradation of PET detector from the 2D flood histogram.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kipritidis, John, E-mail: john.kipritidis@sydney.edu.au; Keall, Paul J.; Siva, Shankar
Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metricsmore » model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant improvements in r{sup ¯} and d{sup ¯}{sub 20} (p < 0.05), with density scaled metrics also showing higher r{sup ¯} than for unscaled versions (p < 0.02). r{sup ¯} and d{sup ¯}{sub 20} were also sensitive to image quality, with statistically significant improvements using standard (as opposed to gated) PET images and with application of median filtering. Conclusions: The use of modified CT ventilation metrics, in conjunction with PET-Galligas and careful application of image filtering has resulted in improved correlation compared to earlier studies using nuclear medicine ventilation. However, CT ventilation and PET-Galligas do not always provide the same functional information. The authors have demonstrated that the agreement can improve for CT ventilation metrics incorporating a tissue density scaling, and also with increasing PET image quality. CT ventilation imaging has clear potential for imaging regional air volume change in the lung, and further development is warranted.« less
Huang, Jianming; Chen, Fengrong; Jian, Guojian; Ye, Zhiyang; Wang, Zimin; Liu, Haoyuan; Kang, Yifan
2015-01-01
Ligament reconstruction is an effective therapy for anterior cruciate ligament (ACL) rupture. Polyethylene terephthalate (PET) artificial ligaments have recently gained popularity in clinical ACL reconstruction for its advantage in the improvement of keen function. However, the application of PET in clinical treatment is limited by its poor bioactivity and biocompatibility. Recently, bone marrow-derived mesenchymal stem cells (BMSCs) have been widely studied in regenerative medical therapy due to their multi-lineage differentiation. Previous study also indicated that BMSCs may promote the healing of tendon-bone interface of injured ligament. We speculate that BMSCs may enhance the curative effect of PET artificial ligament on the tendon-bone-healing in ligament reconstruction. In this study, the PET materials were first modified with sodium hydroxide hydrolysis and GRGDSPC peptide which was able to improve its bioactivity and biocompatibility. Then, the effects of modified PET materials on the adhesion, proliferation and differentiation of BMSCs were examined. The in vitro co-culture of BMSCs and modified PET showed the modified PET promoted the adhesion, proliferation and differentiation of BMSCs. Further, the effect of culture complex of BMSCs and modified PET artificial ligament co-culture system on the injured ligament reconstruction was investigated in vivo. Results showed not only better growth and differentiation of BMSCs but also satisfactory healing of the injured ligament was observed after implantation of this culture complex into the injured ligament of rabbits. Our study provides a brand-new solution for ACL reconstruction. PMID:26221227
Zeglis, Brian M.; Brand, Christian; Abdel-Atti, Dalya; Carnazza, Kathryn E.; Cook, Brendon E.; Carlin, Sean; Reiner, Thomas; Lewis, Jason S.
2015-01-01
Pretargeted PET imaging has emerged as an effective strategy for merging the exquisite selectivity of antibody-based targeting vectors with the rapid pharmacokinetics of radiolabeled small molecules. We previously reported the development of a strategy for the pretargeted PET imaging of colorectal cancer based on the bioorthogonal inverse electron demand Diels–Alder reaction between a tetrazine-bearing radioligand and a transcyclooctene-modified huA33 immunoconjugate. Although this method effectively delineated tumor tissue, its clinical potential was limited by the somewhat sluggish clearance of the radioligand through the gastrointestinal tract. Herein, we report the development and in vivo validation of a pretargeted strategy for the PET imaging of colorectal carcinoma with dramatically improved pharmacokinetics. Two novel tetrazine constructs, Tz-PEG7-NOTA and Tz-SarAr, were synthesized, characterized, and radiolabeled with 64Cu in high yield (>90%) and radiochemical purity (>99%). PET imaging and biodistribution experiments in healthy mice revealed that although 64Cu-Tz-PEG7-NOTA is cleared via both the gastrointestinal and urinary tracts, 64Cu-Tz-SarAr is rapidly excreted by the renal system alone. On this basis, 64Cu-Tz-SarAr was selected for further in vivo evaluation. To this end, mice bearing A33 antigen-expressing SW1222 human colorectal carcinoma xenografts were administered huA33-TCO, and the immunoconjugate was given 24 h to accumulate at the tumor and clear from the blood, after which 64Cu-Tz-SarAr was administered via intravenous tail vein injection. PET imaging and biodistribution experiments revealed specific uptake of the radiotracer in the tumor at early time points (5.6 ± 0.7 %ID/g at 1 h p.i.), high tumor-to-background activity ratios, and rapid elimination of unclicked radioligand. Importantly, experiments with longer antibody accumulation intervals (48 and 120 h) yielded slight decreases in tumoral uptake but also concomitant increases in tumor-to-blood activity concentration ratios. This new strategy offers dosimetric benefits as well, yielding a total effective dose of 0.041 rem/mCi, far below the doses produced by directly labeled 64Cu-NOTA-huA33 (0.133 rem/mCi) and 89Zr-DFO-huA33 (1.54 rem/mCi). Ultimately, this pretargeted PET imaging strategy boasts a dramatically improved pharmacokinetic profile compared to our first generation system and is capable of clearly delineating tumor tissue with high image contrast at only a fraction of the radiation dose created by directly labeled radioimmunoconjugates. PMID:26287993
Zeglis, Brian M; Brand, Christian; Abdel-Atti, Dalya; Carnazza, Kathryn E; Cook, Brendon E; Carlin, Sean; Reiner, Thomas; Lewis, Jason S
2015-10-05
Pretargeted PET imaging has emerged as an effective strategy for merging the exquisite selectivity of antibody-based targeting vectors with the rapid pharmacokinetics of radiolabeled small molecules. We previously reported the development of a strategy for the pretargeted PET imaging of colorectal cancer based on the bioorthogonal inverse electron demand Diels-Alder reaction between a tetrazine-bearing radioligand and a transcyclooctene-modified huA33 immunoconjugate. Although this method effectively delineated tumor tissue, its clinical potential was limited by the somewhat sluggish clearance of the radioligand through the gastrointestinal tract. Herein, we report the development and in vivo validation of a pretargeted strategy for the PET imaging of colorectal carcinoma with dramatically improved pharmacokinetics. Two novel tetrazine constructs, Tz-PEG7-NOTA and Tz-SarAr, were synthesized, characterized, and radiolabeled with (64)Cu in high yield (>90%) and radiochemical purity (>99%). PET imaging and biodistribution experiments in healthy mice revealed that although (64)Cu-Tz-PEG7-NOTA is cleared via both the gastrointestinal and urinary tracts, (64)Cu-Tz-SarAr is rapidly excreted by the renal system alone. On this basis, (64)Cu-Tz-SarAr was selected for further in vivo evaluation. To this end, mice bearing A33 antigen-expressing SW1222 human colorectal carcinoma xenografts were administered huA33-TCO, and the immunoconjugate was given 24 h to accumulate at the tumor and clear from the blood, after which (64)Cu-Tz-SarAr was administered via intravenous tail vein injection. PET imaging and biodistribution experiments revealed specific uptake of the radiotracer in the tumor at early time points (5.6 ± 0.7 %ID/g at 1 h p.i.), high tumor-to-background activity ratios, and rapid elimination of unclicked radioligand. Importantly, experiments with longer antibody accumulation intervals (48 and 120 h) yielded slight decreases in tumoral uptake but also concomitant increases in tumor-to-blood activity concentration ratios. This new strategy offers dosimetric benefits as well, yielding a total effective dose of 0.041 rem/mCi, far below the doses produced by directly labeled (64)Cu-NOTA-huA33 (0.133 rem/mCi) and (89)Zr-DFO-huA33 (1.54 rem/mCi). Ultimately, this pretargeted PET imaging strategy boasts a dramatically improved pharmacokinetic profile compared to our first generation system and is capable of clearly delineating tumor tissue with high image contrast at only a fraction of the radiation dose created by directly labeled radioimmunoconjugates.
NASA Astrophysics Data System (ADS)
Ahmad, A. F.; Razali, A. R.; Razelan, I. S. M.; Jalil, S. S. A.; Noh, M. S. M.; Idris, A. A.
2017-05-01
Plastic bottle for recycling can be found from the household waste stream, and most of them are made from Polyethylene Terephthalate. In this research, PET is utilized to explore the potential prospects to upgrade asphalt mixture properties. The objectives include deciding the best measure of PET to be used. For experimental, Marshall mix design was utilized to determine the ideal bitumen binder content and to test the modified mixture properties. The samples were created per the requirement for aggregate course wearing (ACW14) using the Standard Specification of Road Work (SSRW) in Malaysia. 20 samples were utilized to determine the binder content, and 30 samples were used to research the impact of modifying asphalt mixtures. 2%, 5%, 10%, 15% and 20% of PET by weight of the optimum binder content (4.8%) were tested. Optimum PET content is 10%, and the result shows a good stability with 16.824kN, 2.32g/cm3 bulk density, void filled with bitumen (VFB) with 71.35%, flow with 3.2248mm, air void (AV) with 4.53%, and void of mineral aggregate (VMA) with 15.15%. The outcomes showed that PET modifier gives better engineering properties. Therefore, 10% of PET by the weight of binder content was suggested as the best amount of the modifier.
Scarfone, Christopher; Lavely, William C; Cmelak, Anthony J; Delbeke, Dominique; Martin, William H; Billheimer, Dean; Hallahan, Dennis E
2004-04-01
The aim of this investigation was to evaluate the influence and accuracy of (18)F-FDG PET in target volume definition as a complementary modality to CT for patients with head and neck cancer (HNC) using dedicated PET and CT scanners. Six HNC patients were custom fitted with head and neck and upper body immobilization devices, and conventional radiotherapy CT simulation was performed together with (18)F-FDG PET imaging. Gross target volume (GTV) and pathologic nodal volumes were first defined in the conventional manner based on CT. A segmentation and surface-rendering registration technique was then used to coregister the (18)F-FDG PET and CT planning image datasets. (18)F-FDG PET GTVs were determined and displayed simultaneously with the CT contours. CT GTVs were then modified based on the PET data to form final PET/CT treatment volumes. Five-field intensity-modulated radiation therapy (IMRT) was then used to demonstrate dose targeting to the CT GTV or the PET/CT GTV. One patient was PET-negative after induction chemotherapy. The CT GTV was modified in all remaining patients based on (18)F-FDG PET data. The resulting PET/CT GTV was larger than the original CT volume by an average of 15%. In 5 cases, (18)F-FDG PET identified active lymph nodes that corresponded to lymph nodes contoured on CT. The pathologically enlarged CT lymph nodes were modified to create final lymph node volumes in 3 of 5 cases. In 1 of 6 patients, (18)F-FDG-avid lymph nodes were not identified as pathologic on CT. In 2 of 6 patients, registration of the independently acquired PET and CT data using segmentation and surface rendering resulted in a suboptimal alignment and, therefore, had to be repeated. Radiotherapy planning using IMRT demonstrated the capability of this technique to target anatomic or anatomic/physiologic target volumes. In this manner, metabolically active sites can be intensified to greater daily doses. Inclusion of (18)F-FDG PET data resulted in modified target volumes in radiotherapy planning for HNC. PET and CT data acquired on separate, dedicated scanners may be coregistered for therapy planning; however, dual-acquisition PET/CT systems may be considered to reduce the need for reregistrations. It is possible to use IMRT to target dose to metabolically active sites based on coregistered PET/CT data.
Pretargeted PET Imaging Using a Site-Specifically Labeled Immunoconjugate.
Cook, Brendon E; Adumeau, Pierre; Membreno, Rosemery; Carnazza, Kathryn E; Brand, Christian; Reiner, Thomas; Agnew, Brian J; Lewis, Jason S; Zeglis, Brian M
2016-08-17
In recent years, both site-specific bioconjugation techniques and bioorthogonal pretargeting strategies have emerged as exciting technologies with the potential to improve the safety and efficacy of antibody-based nuclear imaging. In the work at hand, we have combined these two approaches to create a pretargeted PET imaging strategy based on the rapid and bioorthogonal inverse electron demand Diels-Alder reaction between a (64)Cu-labeled tetrazine radioligand ((64)Cu-Tz-SarAr) and a site-specifically modified huA33-trans-cyclooctene immunoconjugate ((ss)huA33-PEG12-TCO). A bioconjugation strategy that harnesses enzymatic transformations and strain-promoted azide-alkyne click chemistry was used to site-specifically append PEGylated TCO moieties to the heavy chain glycans of the colorectal cancer-targeting huA33 antibody. Preclinical in vivo validation studies were performed in athymic nude mice bearing A33 antigen-expressing SW1222 human colorectal carcinoma xenografts. To this end, mice were administered (ss)huA33-PEG12-TCO via tail vein injection and-following accumulation intervals of 24 or 48 h-(64)Cu-Tz-SarAr. PET imaging and biodistribution studies reveal that this strategy clearly delineates tumor tissue as early as 1 h post-injection (6.7 ± 1.7%ID/g at 1 h p.i.), producing images with excellent contrast and high tumor-to-background activity concentration ratios (tumor:muscle = 21.5 ± 5.6 at 24 h p.i.). Furthermore, dosimetric calculations illustrate that this pretargeting approach produces only a fraction of the overall effective dose (0.0214 mSv/MBq; 0.079 rem/mCi) of directly labeled radioimmunoconjugates. Ultimately, this method effectively facilitates the high contrast pretargeted PET imaging of colorectal carcinoma using a site-specifically modified immunoconjugate.
NASA Astrophysics Data System (ADS)
Lin, Tzu-Ping; Yang, Shing-Ru; Chen, Yung-Chang; Matzarakis, Andreas
2018-02-01
Physiologically equivalent temperature (PET) is a thermal index that is widely used in the field of human biometeorology and urban bioclimate. However, it has several limitations, including its poor ability to predict thermo-physiological parameters and its weak response to both clothing insulation and humid conditions. A modified PET (mPET) was therefore developed to address these shortcomings. To determine whether the application of mPET in hot-humid regions is more appropriate than the PET, an analysis of a thermal comfort survey database, containing 2071 questionnaires collected from participants in hot-humid Taiwan, was conducted. The results indicate that the thermal comfort range is similar (26-30 °C) when the mPET and PET are applied as thermal indices to the database. The sensitivity test for vapor pressure and clothing insulation also show that the mPET responds well to the behavior and perceptions of local people in a subtropical climate.
Reiman, Eric M
2011-12-01
Alzheimer's disease (AD) is associated with characteristic and progressive reductions in flourodeoxyglucose positron emission tomography (FDG PET) measurements of the regional cerebral metabolic rate for glucose. These reductions begin years before the onset of symptoms, are correlated with clinical severity, and may help predict an affected patient's clinical course and neuropathological diagnosis. Like several other AD biomarkers, FDG PET has the potential to accelerate the evaluation of AD-modifying treatments, particularly in the earliest clinical and preclinical stages. This article considers FDG PET's role in the detection and tracking of AD, its emerging roles in the evaluation of disease-slowing treatments, some of the issues involved in the acquisition, analysis, and interpretation of FDG PET data, and the evidence needed to help qualify FDG PET and other biomarkers for use in the accelerated approval of AD-slowing treatments. It recommends scientific strategies and public policies to further establish the role of FDG PET and other AD biomarkers in therapeutic trials and find demonstrably effective disease-modifying and presymptomatic AD treatments as quickly as possible. Copyright © 2011 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, C. M., E-mail: christopher.thomas@gstt.nhs.uk; Convery, D. J.; Greener, A. G.
2014-04-15
Purpose: To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. Methods: A PET-CT system was modified with hard-top couch, external lasers and radiotherapy immobilization and indexing devices and was subject to a commissioning and quality assurance program. PET-CT imaging protocols were developed specifically for radiotherapy planning and the image quality and pathway tested using phantoms and five patients recruited into an in-house study. Security and accuracy of data transfer was testedmore » throughout the whole data pathway. The patient pathway was fully established and tested ready for implementation in a PET-guided dose-escalation trial for head and neck cancer patients. Results: Couch deflection was greater than for departmental CT simulator machines. An area of high attenuation in the couch generated image artifacts and adjustments were made accordingly. Using newly developed protocols CT image quality was suitable to maintain delineation and treatment accuracy. Upon transfer of data to the treatment planning system a half pixel offset between PET and CT was observed and corrected. By taking this into account, PET to CT alignment accuracy was maintained below 1 mm in all systems in the data pathway. Transfer of structures delineated in the PET fusion software to the radiotherapy treatment planning system was validated. Conclusions: A method to perform direct PET-guided radiotherapy planning was successfully validated and specific recommendations were developed to assist other centers. Of major concern is ensuring that the quality of PET and CT data is appropriate for radiotherapy treatment planning and on-treatment verification. Couch movements can be compromised, bore-size can be a limitation for certain immobilization techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway.« less
Lethality of Rendang packaged in multilayer retortable pouch with sterilization process
NASA Astrophysics Data System (ADS)
Praharasti, A. S.; Kusumaningrum, A.; Frediansyah, A.; Nurhikmat, A.; Khasanah, Y.; Suprapedi
2017-01-01
Retort Pouch had become a choice to preserve foods nowadays, besides the used of the can. Both had their own advantages, and Retort Pouch became more popular for the reason of cheaper and easier to recycle. General Method usually used to estimate the lethality of commercial heat sterilization process. Lethality value wa s used for evaluating the efficacy of the thermal process. This study aimed to find whether different layers of pouch materials affect the lethality value and to find differences lethality in two types of multilayer retort pouch, PET/Aluminum Foil/Nylon/RCPP and PET/Nylon/Modified Aluminum/CPP. The result showed that the different layer arrangement was resulted different Sterilization Value (SV). PET/Nylon/Modified Aluminum/CPP had better heat penetration, implied by the higher value of lethality. PET/Nylon/Modified Aluminum/CPP had the lethality value of 6,24 minutes, whereas the lethality value of PET/Aluminum Foil/Nylon/RCPP was 3,54 minutes.
Safety assessment of modified terephthalate polymers as used in cosmetics.
Becker, Lillian C; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan
2014-01-01
The safety of 6 modified terephthalate polymers as cosmetic ingredients was assessed. These ingredients mostly function as exfoliants, bulking agents, hair fixatives, and viscosity-increasing agents-nonaqueous. Polyethylene terephthalate (PET) is used in leave-on products up to 100% and in rinse-off products up to 2%. The Cosmetic Ingredient Review Expert Panel (Panel) considered that the PET used in cosmetics is chemically equivalent to that used in medical devices. The Panel determined that the Food and Drug Administration's determination of safety of PET in several medical devices, which included human and animal safety data, can be used as the basis for the determination of safety of PET and related polymers used in cosmetics. Use studies of cosmetic eye products that contain PET demonstrated no ocular irritation or dermal sensitization. The Panel concluded that modified terephthalate polymers were safe as cosmetic ingredients in the practices of use and concentration described in this safety assessment. © The Author(s) 2014.
Halliday, Sue; Thrall, James H
2005-05-01
This chapter discusses how to market to and educate the referral community and third party payers about the benefits of the emerging PET/CT technology. Clearly, the fusion of PET and CT into one piece of equipment will present challenges for years to come. It is important for providers to be involved with all of the administrators, managers, referring and interpreting physicians, and the payer communities in their market to clearly understand individual payer business practices and to identify opportunities to educate and influence changes in payment and coverage policies.
Does pet-keeping modify the association of delivery mode with offspring body size?
Cassidy-Bushrow, Andrea E; Wegienka, Ganesa; Havstad, Suzanne; Levin, Albert M; Lynch, Susan V; Ownby, Dennis R; Rundle, Andrew G; Woodcroft, Kimberley J; Zoratti, Edward M; Johnson, Christine Cole
2015-06-01
Caesarean-section (CS) delivery increases risk of childhood obesity, and is associated with a distinct early-life gut microbiome, which may contribute to obesity. Household pets may alter human gut microbiome composition. We examined if pet-keeping modified the association of CS with obesity at age 2 years in 639 Wayne County Health, Environment, Allergy and Asthma Longitudinal Study birth cohort participants. Pet-keeping was defined as having a dog or cat (indoors ≥1 h/day) at child age 2 years. We used logistic regression to test for an interaction between CS and pet-keeping with obesity (BMI ≥ 95th percentile) at age 2 years, adjusted for maternal obesity. A total of 328 (51.3 %) children were male; 367 (57.4 %) were African American; 228 (35.7 %) were born by CS; and 55 (8.6 %) were obese. After adjusting for maternal obesity, CS-born children had a non-significant (P = 0.25) but elevated 1.4 (95 % CI 0.8, 2.5) higher odds of obesity compared to those born vaginally. There was evidence of effect modification between current pet-keeping and delivery mode with obesity at age 2 years (interaction P = 0.054). Compared to children born vaginally without a pet currently in the home, children born via CS without a pet currently in the home had a statistically significant (P = 0.043) higher odds (odds ratio 2.00; 95 % CI 1.02, 3.93) of being obese at age 2 years. Pets modified the CS-BMI relationship; whether the underlying mechanism is through effects on environmental or gut microbiome requires specific investigation.
NASA Astrophysics Data System (ADS)
Dang, Jun; Frisch, Benjamin; Lasaygues, Philippe; Zhang, Dachun; Tavernier, Stefaan; Felix, Nicolas; Lecoq, Paul; Auffray, Etiennette; Varela, Joao; Mensah, Serge; Wan, Mingxi
2011-06-01
Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Sonic is a project of the Crystal Clear Collaboration and the European Centre for Research on Medical Imaging (CERIMED).
Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh
2016-10-01
A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Hydrophilic-impermeable modified polyethylene terephthalate for selective endothelialization
NASA Astrophysics Data System (ADS)
Chetouane, D.; Fafet, J. F.; Barbet, R.; Dieval, F.
2017-10-01
The aim of this study was to create a modified polyethylene terephthalate (PET) responding to vascular implants’ requirements, mainly with a surface promoting selective endothelialization. The surface alteration was carried out by hydrophilic functionalization in an alkaline solution with the presence of specific surfactant (TA). The carboxylic groups resulting from this reaction were quantified by colorimetric titration using bleu toluidine O dye (TBO). A single-sided coating process was then optimized to cover the PET surface by micro spherical structures’ polymeric layer. This coating provided to the PET surface high impermeability to the water under a pressure of 120 mmHg and enhanced its hydrophilic property. This spherical topography reduced the adhesion of Mesenchymal Stem Cells (MSC) by 37% and inhibited their proliferation after 3 days by 50%. The hydrophilic functionalized PET (PET-TA) surface decreased the MSC adhesion by 50% and promoted HUVEC attachment with a number twice more important than the number of HUVEC adhered onto non treated-PET.
Modified physiologically equivalent temperature—basics and applications for western European climate
NASA Astrophysics Data System (ADS)
Chen, Yung-Chang; Matzarakis, Andreas
2018-05-01
A new thermal index, the modified physiologically equivalent temperature (mPET) has been developed for universal application in different climate zones. The mPET has been improved against the weaknesses of the original physiologically equivalent temperature (PET) by enhancing evaluation of the humidity and clothing variability. The principles of mPET and differences between original PET and mPET are introduced and discussed in this study. Furthermore, this study has also evidenced the usability of mPET with climatic data in Freiburg, which is located in Western Europe. Comparisons of PET, mPET, and Universal Thermal Climate Index (UTCI) have shown that mPET gives a more realistic estimation of human thermal sensation than the other two thermal indices (PET, UTCI) for the thermal conditions in Freiburg. Additionally, a comparison of physiological parameters between mPET model and PET model (Munich Energy Balance Model for Individual, namely MEMI) is proposed. The core temperatures and skin temperatures of PET model vary more violently to a low temperature during cold stress than the mPET model. It can be regarded as that the mPET model gives a more realistic core temperature and mean skin temperature than the PET model. Statistical regression analysis of mPET based on the air temperature, mean radiant temperature, vapor pressure, and wind speed has been carried out. The R square (0.995) has shown a well co-relationship between human biometeorological factors and mPET. The regression coefficient of each factor represents the influence of the each factor on changing mPET (i.e., ±1 °C of T a = ± 0.54 °C of mPET). The first-order regression has been considered predicting a more realistic estimation of mPET at Freiburg during 2003 than the other higher order regression model, because the predicted mPET from the first-order regression has less difference from mPET calculated from measurement data. Statistic tests recognize that mPET can effectively evaluate the influences of all human biometeorological factors on thermal environments. Moreover, a first-order regression function can also predict the thermal evaluations of the mPET by using human biometeorological factors in Freiburg.
High-performance polymer/layered silicate nanocomposites
NASA Astrophysics Data System (ADS)
Heidecker, Matthew J.
High-performance layered-silicate nanocomposites of Polycarbonate (PC), poly(ethylene terephthalate) (PET), and their blends were produced via conventional melt-blending techniques. The focus of this thesis was on the fundamentals of dispersion, control of thermal stability, maintenance of melt-blending processing conditions, and on optimization of the composites' mechanical properties via the design of controlled and thermodynamically favorable nano-filler dispersions within the polymer matrices. PET and PC require high temperatures for melt-processing, rendering impractical the use of conventional/commercial organically-modified layered-silicates, since the thermal degradation temperatures of their ammonium surfactants lies below the typical processing temperatures. Thus, different surfactant chemistries must be employed in order to develop melt-processable nanocomposites, also accounting for polymer matrix degradation due to water (PET) or amine compounds (PC). Novel high thermal-stability surfactants were developed and employed in montmorillonite nanocomposites of PET, PC, and PC/PET blends, and were compared to the respective nanocomposites based on conventional quaternary-ammonium modified montmorillonites. Favorable dispersion was achieved in all cases, however, the overall material behavior -- i.e., the combination of crystallization, mechanical properties, and thermal degradation -- was better for the nanocomposites based on the thermally-stable surfactant fillers. Studies were also done to trace, and ultimately limit, the matrix degradation of Polycarbonate/montmorillonite nanocomposites, through varying the montmorillonite surfactant chemistry, processing conditions, and processing additives. Molecular weight degradation was, maybe surprisingly, better controlled in the conventional quaternary ammonium based nanocomposites -- even though the thermal stability of the organically modified montmorillonites was in most cases the lowest. Dependence of the resultant nanocomposites' mechanical properties on the preferential alignment of the montmorillonite nano-platelet was also evaluated. Highly aligned filler platelets did not result in an additional enhancement in mechanical properties. PC/PET blends and their respective PC/PET/montmorillonite nanocomposites were synthesized and compared. The dispersion of the organically modified nano-fillers in the PC/PET blends was controlled via thermodynamic considerations, realized through proper surfactant choice: Nanocomposites in which the layered silicate was preferentially sequestered in the PET phase were designed and synthesized. This preferential dispersion of the nano-filler in the PET phase of the PC/PET blend was insensitive to processing conditions, including approaches employing a master-batch (filler concentrate); regardless of the master-batch matrix, both PC and PET were employed, thermodynamics drove the layered silicate to preferentially migrate to the PET phase of the PC/PET blend. In a second approach, the development of a nanocomposite with controlled PC/PET compatibilization near the montmorillonite platelets, in absence of appreciable transesterification reactions, led to the formation of very high performance nanocomposites. These latter systems, point to an exciting new avenue of future considerations for nanocomposite blends with selective nano-filler dispersions, where performance can be tailored via the controlled preferential dispersion of nano-fillers in one phase, or by filler-induced polymer compatibilization.
Improvement of PET surface hydrophilicity and roughness through blending
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolahchi, Ahmad Rezaei; Ajji, Abdellah; Carreau, Pierre J.
Controlling the adhesion of the polymer surface is a key issue in surface science, since polymers have been a commonly used material for many years. The surface modification in this study includes two different aspects. One is to enhance the hydrophilicity and the other is to create the roughness on the PET film surface. In this study we developed a novel and simple approach to modify polyethylene terephthalate (PET) film surface through polymer blending in twin-screw extruder. One example described in the study uses polyethylene glycol (PEG) in polyethylene terephthalate (PET) host to modify a PET film surface. Low contentmore » of polystyrene (PS) as a third component was used in the system to increase the rate of migration of PEG to the surface of the film. Surface enrichment of PEG was observed at the polymer/air interface of the polymer film containing PET-PEG-PS whereas for the PET-PEG binary blend more PEG was distributed within the bulk of the sample. Furthermore, a novel method to create roughness at the PET film surface was proposed. In order to roughen the surface of PET film, a small amount of PKHH phenoxy resin to change PS/PET interfacial tension was used. The compatibility effect of PKHH causes the formation of smaller PS droplets, which were able to migrate more easily through PET matrix. Consequently, resulting in a locally elevated concentration of PS near the surface of the film. The local concentration of PS eventually reached a level where a co-continuous morphology occurred, resulting in theinstabilities on the surface of the film.« less
Thin transparent titania (TiO2) films were coated on the surface of flexible poly (ethylene terephthalate) (PET) surface using standard sol gel techniques. The TiO2/PET thin film surfaces were further modified by exposing the films to a RF glow discharge oxygen plasma. The exposu...
Orunmuyi, Akintunde; Modiselle, Moshe; Lengana, Thabo; Ebenhan, Thomas; Vorster, Mariza; Sathekge, Mike
2017-09-01
We report the case of a 32 year-old male with Chondroblastic Osteosarcoma of the skull, which was imaged with both 18 [F]fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) and 68 Gallium-arginine-glycine-aspartic acid ( 68 Ga-RGD) PET/CT. The 18 F-FDG PET/CT did not demonstrate the tumour, whereas the 68 Ga-RGD PET/CT clearly depicted a left-sided frontal tumour. 68 Ga-RGD PET/CT may be a clinically useful imaging modality for early detection of recurrent osteosarcoma, considering the limitations of 18 F-FDG PET in a setting of low glycolytic activity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaonkar, Amita, E-mail: ami.gaonkar@gmail.com; Murudkar, Vrishali, E-mail: vru0077@gmail.com; Deshpande, V. D., E-mail: vindesh2@rediffmail.com
2016-05-06
Polyethylene terephthalate (PET) and Nucleated PET/ multi-walled carbon nanotubes (MWCNTs) nanocomposites with different MWCNTs loadings were prepared by melt compounding. The influence of the addition of MWCNTs and precipitated PET (p-PET) on the morphology and thermal properties of the nanocomposites was investigated. From Transmission Electronic Microscopy (TEM) and Wide angle X-Ray diffraction (WAXD) study, it can be clearly seen that nanocomposites with low MWCNTs contents (0.1 wt. %) get better MWCNTs dispersion than higher MWCNT loading. Comparing with PET, nucleated PET nanocomposite with 0.1% MWCNT loading shows higher value of Lauritzen-Hoffman parameters U* and Kg evaluated using the differential isoconversionalmore » method. Crystallization regime transition temperature range shifts to higher temperature (208°C - 215°C) for nanocomposites. The presence of p-PET in addition of MWCNT, which act as good nucleating agent, enhanced the crystallization of PET through heterogeneous nucleation.« less
NASA Astrophysics Data System (ADS)
Gaonkar, Amita; Murudkar, Vrishali; Deshpande, V. D.
2016-05-01
Polyethylene terephthalate (PET) and Nucleated PET/ multi-walled carbon nanotubes (MWCNTs) nanocomposites with different MWCNTs loadings were prepared by melt compounding. The influence of the addition of MWCNTs and precipitated PET (p-PET) on the morphology and thermal properties of the nanocomposites was investigated. From Transmission Electronic Microscopy (TEM) and Wide angle X-Ray diffraction (WAXD) study, it can be clearly seen that nanocomposites with low MWCNTs contents (0.1 wt. %) get better MWCNTs dispersion than higher MWCNT loading. Comparing with PET, nucleated PET nanocomposite with 0.1% MWCNT loading shows higher value of Lauritzen-Hoffman parameters U* and Kg evaluated using the differential isoconversional method. Crystallization regime transition temperature range shifts to higher temperature (208°C - 215°C) for nanocomposites. The presence of p-PET in addition of MWCNT, which act as good nucleating agent, enhanced the crystallization of PET through heterogeneous nucleation.
Reiman, Eric M.
2012-01-01
Alzheimer’s disease (AD) is associated with characteristic and progressive reductions in flourodeoxyglucose positron emission tomography (FDG PET) measurements of the regional cerebral metabolic rate for glucose. These reductions begin years before the onset of symptoms, are correlated with clinical severity, and may help predict an affected patient’s clinical course and neuropathological diagnosis. Like several other AD biomarkers, FDG PET has the potential to accelerate the evaluation of these treatments, particularly in the earliest clinical and preclinical stages. This article considers FDG PET’s role in the detection and tracking of AD, its emerging roles in the evaluation of disease-slowing treatments, some of the issues involved in the acquisition, analysis, and interpretation of FDG PET data, and the evidence needed to help qualify FDG PET and other biomarkers for use in the accelerated approval of AD-slowing treatments. It recommends scientific strategies and public policies to further establish the role of FDG PET and other AD biomarkers in therapeutic trials and find demonstrably effective disease-modifying and presymptomatic AD treatments as quickly as possible. PMID:21983241
PET fiber fabrics modified with bioactive titanium oxide for bone substitutes.
Kokubo, Tadashi; Ueda, Takahiro; Kawashita, Masakazu; Ikuhara, Yuichi; Takaoka, Gikan H; Nakamura, Takashi
2008-02-01
A rectangular specimen of polyethylene terephthalate (PET) was soaked in a titania solution composed of titanium isopropoxide, water, ethanol and nitric acid at 25 degrees C for 1 h. An amorphous titanium oxide was formed uniformly on the surface of PET specimen, but did not form an apatite on its surface in a simulated body fluid (SBF) within 3 d. The PET plate formed with the amorphous titanium oxide was subsequently soaked in water or HCl solutions with different concentrations at 80 degrees C for different periods of time. The titanium oxide on PET was transformed into nano-sized anatase by the water treatment and into nano-sized brookite by 0.10 M HCl treatment at 80 degrees C for 8 d. The former did not form the apatite on its surface in SBF within 3 d, whereas the latter formed the apatite uniformly on its surface. Adhesive strength of the titanium oxide and apatite layers to PET plate was increased by pre-treatment of PET with 2 wt% NaOH solution at 40 degrees C for 2 h. A two-dimensional fabric of PET fibers 24 microm in diameter was subjected to the NaOH pre-treatment at 40 degrees C, titania solution treatment at 25 degrees C and subsequent 0.10 M HCl treatment at 80 degrees C. Thus treated PET fabric formed the apatite uniformly on surfaces of individual fibers constituting the fabric in SBF within 3 d. Two or three dimensional PET fabrics modified with the nano-sized brookite on surfaces of the individual fibers constituting the fabric by the present method are believed to be useful as flexible bone substitutes, since they could be integrated with living bone through the apatite formed on their constituent fibers.
Asiimwe, J K; Quilty, B; Muyanja, C K; McGuigan, K G
2013-12-01
Concerns about photodegradation products leaching from plastic bottle material into water during solar water disinfection (SODIS) are a major psychological barrier to increased uptake of SODIS. In this study, a comparison of SODIS efficacy using glass and plastic polyethylene terephalate (PET) bottles was carried out under strong real sunlight and overcast weather conditions at Makerere University in central Uganda. Both clear and turbid natural water samples from shallow wells and open dug wells, respectively, were used. Efficacy was determined from the inactivation of a wild strain of Escherichia coli in solar-exposed contaminated water in both glass and PET bottles. The studies reveal no significant difference in SODIS inactivation between glass and PET bottles (95% CI, p > 0.05), for all water samples under the different weather conditions except for clear water under overcast conditions where there was a small but significant difference (95% CI, p = 0.047) with less viable bacterial counts in PET bottles at two intermediate time points but not at the end of the exposure. The results demonstrate that SODIS efficacy in glass under tropical field conditions is comparable to PET plastic. SODIS users in these regions can choose either of reactors depending on availability and preference of the user.
Dong, Baiyan; Jiang, Hongquan; Manolache, Sorin; Wong, Amy C Lee; Denes, Ferencz S
2007-06-19
A simple cold plasma technique was developed to functionalize the surfaces of polyamide (PA) and polyester (PET) for the grafting of polyethylene glycol (PEG) with the aim of reducing biofilm formation. The surfaces of PA and PET were treated with silicon tetrachloride (SiCl4) plasma, and PEG was grafted onto plasma-functionalized substrates (PA-PEG, PET-PEG). Different molecular weights of PEG and grafting times were tested to obtain optimal surface coverage by PEG as monitored by electron spectroscopy for chemical analysis (ESCA). The presence of a predominant C-O peak on the PEG-modified substrates indicated that the grafting was successful. Data from hydroxyl group derivatization and water contact angle measurement also indicated the presence of PEG after grafting. The PEG-grafted PA and PET under optimal conditions had similar chemical composition and hydrophilicity; however, different morphology changes were observed after grafting. Both PA-PEG and PET-PEG surfaces developed under optimal plasma conditions showed about 96% reduction in biofilm formation by Listeria monocytogenes compared with that of the corresponding unmodified substrates. This plasma functionalization method provided an efficient way to graft PEG onto PA and PET surfaces. Because of the high reactivity of Si-Cl species, this method could potentially be applied to other polymeric materials.
Performance evaluation of a LYSO-based PET scanner for monitoring of dose delivery in hadrontherapy
NASA Astrophysics Data System (ADS)
Fabbiani, E.; Belcari, N.; Camarlinghi, N.; Del Guerra, A.; Ferretti, S.; Kraan, A.; Panetta, D.; Sportelli, G.; Rosso, V.
2015-12-01
The DoPET scanner is a compact positron emission tomography (PET) device. It has been developed for monitoring the range of charged particles during therapy with hadron beams. Previous works have focused on the development and upgrade of the device and on data analysis. In this paper, a full performance characterization of the DoPET system in terms of the energy resolution, spatial resolution, sensitivity, uniformity, and noise equivalent count rate is reported. All measurements refer to an adapted version of the National Electrical Manufacturers Association (NEMA) NU 4 - 2008 protocol, which was written originally for small animal PET systems. Since DoPET is a dual head planar system, it requires a modified characterisation procedure with respect to those described for ring geometries as in the NEMA NU 4 - 2008 protocol. The presented procedure may be of interest for any other PET system with a similar geometry as DoPET.
Deng, Huaifu; Wang, Hui; Wang, Mengzhe; Li, Zibo; Wu, Zhanhong
2015-08-03
Overexpression of neurotensin receptors (NTRs) has been suggested to play important roles in the growth and survival of a variety of tumor types. The aim of this study is to develop a dual-modality probe (64Cu -DOTA-NT-Cy5.5) for imaging NTR1 expression in vivo with both positron emission tomography (PET) and fluorescence. In this approach, the thiol group and N terminal amino group of neurotensin analogue (Cys-NT) were chemically modified with Cy5.5 dye and DOTA chelator, respectively. After radiolabeling with 64Cu, the resulting probe (64Cu-DOTA-NT-Cy5.5) was evaluated in NTR1 positive HT-29 tumor model. Small animal PET quantification analysis demonstrated that the tumor uptake was 1.91±0.22 and 1.79±0.16%ID/g at 1 and 4 h postinjection (p.i.), respectively. The tumor-to-muscle ratio was 17.44±3.25 at 4 h p.i. based on biodistribution. Receptor specificity was confirmed by the successful blocking experiment at 4 h p.i. (0.42±0.05%ID/g). In parallel with PET experiment, fluorescence imaging was also performed, which demonstrated prominent tumor uptake in HT-29 model. As a proof of concept, an imaging guided surgery was performed to the fluorescent moiety of this probe and could provide potential surgery guidance for NTR positive patients. In summary, our results clearly indicated that the dual-modality probe, 64Cu-DOTA-NT-Cy5.5, could serve as a promising agent to image NTR positive tumors in vivo.
Development of ClearPEM-Sonic, a multimodal mammography system for PET and Ultrasound
NASA Astrophysics Data System (ADS)
Cucciati, G.; Auffray, E.; Bugalho, R.; Cao, L.; Di Vara, N.; Farina, F.; Felix, N.; Frisch, B.; Ghezzi, A.; Juhan, V.; Jun, D.; Lasaygues, P.; Lecoq, P.; Mensah, S.; Mundler, O.; Neves, J.; Paganoni, M.; Peter, J.; Pizzichemi, M.; Siles, P.; Silva, J. C.; Silva, R.; Tavernier, S.; Tessonnier, L.; Varela, J.
2014-03-01
ClearPEM-Sonic is an innovative imaging device specifically developed for breast cancer. The possibility to work in PEM-Ultrasound multimodality allows to obtain metabolic and morphological information increasing the specificity of the exam. The ClearPEM detector is developed to maximize the sensitivity and the spatial resolution as compared to Whole-Body PET scanners. It is coupled with a 3D ultrasound system, the SuperSonic Imagine Aixplorer that improves the specificity of the exam by providing a tissue elasticity map. This work describes the ClearPEM-Sonic project focusing on the technological developments it has required, the technical merits (and limits) and the first multimodal images acquired on a dedicated phantom. It finally presents selected clinical case studies that confirm the value of PEM information.
NASA Astrophysics Data System (ADS)
Zakhnini, Abdelhamid; Kulenkampff, Johannes; Sauerzapf, Sophie; Pietrzyk, Uwe; Lippmann-Pipke, Johanna
2013-08-01
Understanding conservative fluid flow and reactive tracer transport in soils and rock formations requires quantitative transport visualization methods in 3D+t. After a decade of research and development we established the GeoPET as a non-destructive method with unrivalled sensitivity and selectivity, with due spatial and temporal resolution by applying Positron Emission Tomography (PET), a nuclear medicine imaging method, to dense rock material. Requirements for reaching the physical limit of image resolution of nearly 1 mm are (a) a high-resolution PET-camera, like our ClearPET scanner (Raytest), and (b) appropriate correction methods for scatter and attenuation of 511 keV—photons in the dense geological material. The latter are by far more significant in dense geological material than in human and small animal body tissue (water). Here we present data from Monte Carlo simulations (MCS) reflecting selected GeoPET experiments. The MCS consider all involved nuclear physical processes of the measurement with the ClearPET-system and allow us to quantify the sensitivity of the method and the scatter fractions in geological media as function of material (quartz, Opalinus clay and anhydrite compared to water), PET isotope (18F, 58Co and 124I), and geometric system parameters. The synthetic data sets obtained by MCS are the basis for detailed performance assessment studies allowing for image quality improvements. A scatter correction method is applied exemplarily by subtracting projections of simulated scattered coincidences from experimental data sets prior to image reconstruction with an iterative reconstruction process.
Katoh, Chietsugu; Yoshinaga, Keiichiro; Klein, Ran; Kasai, Katsuhiko; Tomiyama, Yuuki; Manabe, Osamu; Naya, Masanao; Sakakibara, Mamoru; Tsutsui, Hiroyuki; deKemp, Robert A; Tamaki, Nagara
2012-08-01
Myocardial blood flow (MBF) estimation with (82)Rubidium ((82)Rb) positron emission tomography (PET) is technically difficult because of the high spillover between regions of interest, especially due to the long positron range. We sought to develop a new algorithm to reduce the spillover in image-derived blood activity curves, using non-uniform weighted least-squares fitting. Fourteen volunteers underwent imaging with both 3-dimensional (3D) (82)Rb and (15)O-water PET at rest and during pharmacological stress. Whole left ventricular (LV) (82)Rb MBF was estimated using a one-compartment model, including a myocardium-to-blood spillover correction to estimate the corresponding blood input function Ca(t)(whole). Regional K1 values were calculated using this uniform global input function, which simplifies equations and enables robust estimation of MBF. To assess the robustness of the modified algorithm, inter-operator repeatability of 3D (82)Rb MBF was compared with a previously established method. Whole LV correlation of (82)Rb MBF with (15)O-water MBF was better (P < .01) with the modified spillover correction method (r = 0.92 vs r = 0.60). The modified method also yielded significantly improved inter-operator repeatability of regional MBF quantification (r = 0.89) versus the established method (r = 0.82) (P < .01). A uniform global input function can suppress LV spillover into the image-derived blood input function, resulting in improved precision for MBF quantification with 3D (82)Rb PET.
Effect of {sup 18}F-FDG PET/CT Imaging in Patients With Clinical Stage II and III Breast Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groheux, David; Moretti, Jean-Luc; EAD Imagerie Moleculaire Diagnostique et Ciblage Therapeutique, IUH, University of Paris VII, Paris
2008-07-01
Purpose: To investigate the potential effect of using {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) in the initial assessment of patients with clinical Stage II or III breast cancer. Methods and Materials: During 14 consecutive months, 39 patients (40 tumors) who presented with Stage II or III breast cancer on the basis of a routine extension assessment were prospectively included in this study. PET/CT was performed in addition to the initial assessment. Results: In 3 cases, PET/CT showed extra-axillary lymph node involvement that had not been demonstrated with conventional techniques. Two of these patients had hypermetabolic lymph nodes in themore » subpectoral and infraclavicular regions, and the third had a hypermetabolic internal mammary node. PET/CT showed distant uptake in 4 women. Of these 4 women, 1 had pleural involvement and 3 had bone metastasis. Overall, of the 39 women, the PET/CT results modified the initial stage in 7 (18%). The modified staging altered the treatment plan for 5 patients (13%). It led to radiotherapy in 4 patients (bone metastasis, pleural lesion, subpectoral lymph nodes, and internal mammary nodes) and excision of, and radiotherapy to, the infraclavicular lymph nodes in 1 patient. Conclusions: PET/CT can provide information on extra-axillary lymph node involvement and can uncover occult distant metastases in a significant percentage of patients. Therefore, initial PET/CT could enable better treatment planning for patients with Stage II and III breast cancer.« less
Characterization of surface modified polyester fabric.
Joseph, Roy; Shelma, R; Rajeev, A; Muraleedharan, C V
2009-12-01
Woven polyethylene terephthalate (PET) fabric has been used in the construction of vascular grafts and sewing ring of prosthetic heart valves. In an effort to improve haemocompatibility and tissue response to PET fabric, a fluoropolymer, polyvinylidine fluoride (PVDF), was coated on PET fabric by dip coating technique. The coating was found to be uniform and no significant changes occurred on physical properties such as water permeability and burst strength. Cell culture cytotoxicity studies showed that coated PET was non-cytotoxic to L929 fibroblast cell lines. In vitro studies revealed that coating improved haemocompatibility of PET fabric material. Coating reduced platelet consumption of PET fabric by 50%. Upon surface modification leukocyte consumption of PET was reduced by 24%. About 60% reduction in partial thromboplastin time (PTT) observed when PET was coated with PVDF. Results of endothelial cell proliferation studies showed that surface coating did not have any substantial impact on cell proliferation. Overall results indicate that coating has potential to improve haemocompatibility of PET fabric without affecting its mechanical performance.
Hybrid registration of PET/CT in thoracic region with pre-filtering PET sinogram
NASA Astrophysics Data System (ADS)
Mokri, S. S.; Saripan, M. I.; Marhaban, M. H.; Nordin, A. J.; Hashim, S.
2015-11-01
The integration of physiological (PET) and anatomical (CT) images in cancer delineation requires an accurate spatial registration technique. Although hybrid PET/CT scanner is used to co-register these images, significant misregistrations exist due to patient and respiratory/cardiac motions. This paper proposes a hybrid feature-intensity based registration technique for hybrid PET/CT scanner. First, simulated PET sinogram was filtered with a 3D hybrid mean-median before reconstructing the image. The features were then derived from the segmented structures (lung, heart and tumor) from both images. The registration was performed based on modified multi-modality demon registration with multiresolution scheme. Apart from visual observations improvements, the proposed registration technique increased the normalized mutual information index (NMI) between the PET/CT images after registration. All nine tested datasets show marked improvements in mutual information (MI) index than free form deformation (FFD) registration technique with the highest MI increase is 25%.
Tijink, Bernard M; Perk, Lars R; Budde, Marianne; Stigter-van Walsum, Marijke; Visser, Gerard W M; Kloet, Reina W; Dinkelborg, Ludger M; Leemans, C René; Neri, Dario; van Dongen, Guus A M S
2009-08-01
The human monoclonal antibody (MAb) fragment L19-SIP is directed against extra domain B (ED-B) of fibronectin, a marker of tumour angiogenesis. A clinical radioimmunotherapy (RIT) trial with (131)I-L19-SIP was recently started. In the present study, after GMP production of (124)I and efficient production of (124)I-L19-SIP, we aimed to demonstrate the suitability of (124)I-L19-SIP immuno-PET for imaging of angiogenesis at early-stage tumour development and as a scouting procedure prior to clinical (131)I-L19-SIP RIT. (124)I was produced in a GMP compliant way via (124)Te(p,n)(124)I reaction and using a TERIMO module for radioiodine separation. L19-SIP was radioiodinated by using a modified version of the IODO-GEN method. The biodistribution of coinjected (124)I- and (131)I-L19-SIP was compared in FaDu xenograft-bearing nude mice, while (124)I PET images were obtained from mice with tumours of <50 to approximately 700 mm(3). (124)I was produced highly pure with an average yield of 15.4 +/- 0.5 MBq/microAh, while separation yield was approximately 90% efficient with <0.5% loss of TeO(2). Overall labelling efficiency, radiochemical purity and immunoreactive fraction were for (124)I-L19-SIP: approximately 80 , 99.9 and >90%, respectively. Tumour uptake was 7.3 +/- 2.1, 10.8 +/- 1.5, 7.8 +/- 1.4, 5.3 +/- 0.6 and 3.1 +/- 0.4%ID/g at 3, 6, 24, 48 and 72 h p.i., resulting in increased tumour to blood ratios ranging from 6.0 at 24 h to 45.9 at 72 h p.i.. Fully concordant labelling and biodistribution results were obtained with (124)I- and (131)I-L19-SIP. Immuno-PET with (124)I-L19-SIP using a high-resolution research tomograph PET scanner revealed clear delineation of the tumours as small as 50 mm(3) and no adverse uptake in other organs. (124)I-MAb conjugates for clinical immuno-PET can be efficiently produced. Immuno-PET with (124)I-L19-SIP appeared qualified for sensitive imaging of tumour neovasculature and for predicting (131)I-L19-SIP biodistribution.
Pizzi, María N; Dos-Subirà, L; Roque, Albert; Fernández-Hidalgo, Nuria; Cuéllar-Calabria, Hug; Pijuan Domènech, Antonia; Gonzàlez-Alujas, María T; Subirana-Domènech, M T; Miranda-Barrio, B; Ferreira-González, Ignacio; González-López, Juan J; Igual, Albert; Maisterra-Santos, Olga; García-Dorado, David; Castell-Conesa, Joan; Almirante, Benito; Escobar Amores, Manuel; Tornos, Pilar; Aguadé-Bruix, Santiago
2017-12-01
Infective endocarditis (IE) and cardiac device infection (CDI) are a major complication in the growing number of patients with congenital heart disease (CHD) reaching adulthood. We aimed to evaluate the added value of 18 F-FDG-PET/CT angiography (PET/CTA) in the diagnosis of IE-CDI in adults with CHD and intravascular or intracardiac prosthetic material, in whom echocardiography (ECHO) and modified Duke Criteria (DC) have limitations because of the patients' complex anatomy. A prospective study was conducted in a referral center with multidisciplinary IE and CHD Units. PET/CTA and ECHO findings were compared in consecutive adult (≥18years) patients with CHD who have prosthetic material and suspected IE-CDI. The initial diagnosis using the DC and the diagnosis with the additional PET/CTA data (DC+PET/CTA) were compared with the final diagnostic consensus established by an expert team at three months. Between November-2012 and April-2017, 25 patients (15 men; median age 40years) were included. Cases were initially classified as definite in 8 (32%), possible in 14 (56%) and rejected in 3 (12%). DC+PET/CTA allowed reclassification of 12/14 (86%) cases initially identified as possible IE. The sensitivity, specificity, PPV, NPV, and accuracy of DC at IE suspicion were 39.1%/83.3%/90.4%/25.5%/61.2%, respectively. The diagnostic performance increased significantly with addition of PET/CTA data: 87%/83.3%/95.4%/61.5%/85.1%, respectively. PET/CTA also provided an alternative diagnosis in 3 patients with rejected IE, and detected pulmonary embolisms in 3 patients. PET/CTA was a useful diagnostic tool in the complex group of adult patients with CHD who have cardiac or intravascular prosthetic material and suspected IE or CDI, providing added diagnostic value to the modified DC (increased sensitivity) and improving case classification. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Effect of compatibilizer on impact and morphological analysis of recycled HDPE/PET blends
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salleh, Mohd Nazry; Ahmad, Sahrim; Ghani, Mohd Hafizuddin Ab
Blends based on recycled high density polyethylene (rHDPE) and recycled polyethylene terephthalate (rPET) were prepared using a corotating twin screw extruder. PET and HDPE are incompatible polymers and their blends showed poor properties. Compatibilization is a step to obtain blends with good mechanical properties and in this work, ethylene glycidyl methacrylate copolymer (E-GMA) was used as a compatibilizing agent. The effect of blends based on rHDPE and rPET with and without a compatibilizer, E-GMA were examined. From the studies clearly showed that the addition of 5% E-GMA increased the impact strength. SEM analysis of rHDPE/rPET blends confirmed the morphological interactionmore » and improved interfacial bonding between two phases.« less
Antibody-based PET imaging of amyloid beta in mouse models of Alzheimer's disease
Sehlin, Dag; Fang, Xiaotian T.; Cato, Linda; Antoni, Gunnar; Lannfelt, Lars; Syvänen, Stina
2016-01-01
Owing to their specificity and high-affinity binding, monoclonal antibodies have potential as positron emission tomography (PET) radioligands and are currently used to image various targets in peripheral organs. However, in the central nervous system, antibody uptake is limited by the blood–brain barrier (BBB). Here we present a PET ligand to be used for diagnosis and evaluation of treatment effects in Alzheimer's disease. The amyloid β (Aβ) antibody mAb158 is radiolabelled and conjugated to a transferrin receptor antibody to enable receptor-mediated transcytosis across the BBB. PET imaging of two different mouse models with Aβ pathology clearly visualize Aβ in the brain. The PET signal increases with age and correlates closely with brain Aβ levels. Thus, we demonstrate that antibody-based PET ligands can be successfully used for brain imaging. PMID:26892305
Clinical role of early dynamic FDG-PET/CT for the evaluation of renal cell carcinoma.
Nakajima, Reiko; Abe, Koichiro; Kondo, Tsunenori; Tanabe, Kazunari; Sakai, Shuji
2016-06-01
We studied the usefulness of early dynamic (ED) and whole-body (WB) FDG-PET/CT for the evaluation of renal cell carcinoma (RCC). One hundred patients with 107 tumours underwent kidney ED and WB FDG-PET/CT. We visually and semiquantitatively evaluated the FDG accumulation in RCCs in the ED and WB phases, and compared the accumulation values with regard to histological type (clear cell carcinoma [CCC] vs. non-clear cell carcinoma [N-CCC]), the TNM stage (high stage [3-4] vs. low stage [1-2]), the Fuhrman grade (high grade [3-4] vs. low grade [1-2]) and presence versus absence of venous (V) and lymphatic (Ly) invasion. In the ED phase, visual evaluation revealed no significant differences in FDG accumulation in terms of each item. However, the maximum standardized uptake value and tumour-to-normal tissue ratios were significantly higher in the CCCs compared to the N-CCCs (p < 0.001). In the WB phase, in contrast, significantly higher FDG accumulation (p < 0.001) was found in RCCs with a higher TNM stage, higher Furman grade, and the presence of V and Ly invasion in both the visual and the semiquantitative evaluations. ED and WB FDG-PET/CT is a useful tool for the evaluation of RCCs. • ED and WB FDG-PET/ CT helps to assess patients with RCC • ED FDG-PET/CT enabled differentiation between CCC and N-CCC • FDG accumulation in the WB phase reflects tumour aggressiveness • Management of RCC is improved by ED and WB FDG-PET/CT.
Wisdom, Jennifer P; Saedi, Goal Auzeen; Green, Carla A
2009-07-01
This study elucidates the role of pets in recovery processes among adults with serious mental illness. Data derive from interviews with 177 HMO members with serious mental illness (52.2% women, average age 48.8 years) in the Study of Transitions and Recovery Strategies (STARS). Interviews and questionnaires addressed factors affecting recovery processes and included questions about pet ownership. Data were analyzed using a modified grounded theory method to identify the roles pets play in the recovery process. Primary themes indicate pets assist individuals in recovery from serious mental illness by (a) providing empathy and "therapy"; (b) providing connections that can assist in redeveloping social avenues; (c) serving as "family" in the absence of or in addition to human family members; and (d) supporting self-efficacy and strengthening a sense of empowerment. Pets appear to provide more benefits than merely companionship. Participants' reports of pet-related contributions to their well-being provide impetus to conduct more formal research on the mechanisms by which pets contribute to recovery and to develop pet-based interventions.
Wisdom, Jennifer P.; Saedi, Goal Auzeen; Green, Carla A.
2010-01-01
This study elucidates the role of pets in recovery processes among adults with serious mental illness. Data derive from interviews with 177 HMO members with serious mental illness (52.2% women, average age 48.8). Interviews and questionnaires addressed factors affecting recovery processes and included questions about pet ownership. Data were analyzed using a modified grounded theory method to identify the roles pets play in the recovery process. Primary themes indicate pets assist individuals in recovery from serious mental illness by (a) providing empathy and “therapy”; (b) providing connections that can assist in redeveloping social avenues; (c) serving as “family” in the absence of or in addition to human family members; and (d) supporting self-efficacy and strengthening a sense of empowerment. Pets appear to provide more benefits than merely companionship. Participants’ reports of pet-related contributions to their well-being provide impetus to conduct more formal research on the mechanisms by which pets contribute to recovery and to develop pet-based interventions. PMID:19839680
The Heritage of Radiotracers for PET
DOE R&D Accomplishments Database
Fowler, J. S.; Wolf, A. P.
1988-05-01
The history of PET research clearly demonstrates that it is advances in chemistry coupled with a detailed examination of the biochemistry of new radiotracers which has allowed the PET method to be applied to new areas of biology and medicine. Radiotracers whose regional distribution reflects glucose metabolism, neutrotransmitter activity and enzyme activity have all required the development of rapid synthetic methods for the radiotracers themselves and the characterization of their biochemical behavior. This article traces some of the advances in the production of labeled precursors and in radiotracer synthesis and evaluation which have shaped the rapidly expanding application of PET to problems in the neurosciences, in cardiology and in oncology.
Soil-release behaviour of polyester fabrics after chemical modification with polyethylene glycol
NASA Astrophysics Data System (ADS)
Miranda, T. M. R.; Santos, J.; Soares, G. M. B.
2017-10-01
The fibres cleanability depends, among other characteristics, on their hydrophilicity. Hydrophilic fibres are easy-wash materials but hydrophobic fibres are difficult to clean due to their higher water-repellent surfaces. This type of surfaces, like polyester (PET), produce an accumulation of electrostatic charges, which favors adsorption and retention of dirt. Thus, the polyester soil-release properties can be increased by finishing processes that improve fiber hydrophilicity. In present study, PET fabric modification was described by using poly(ethylene glycol) (PEG) and N,N´-dimethylol-4,5-dihydroxyethylene urea (DMDHEU) chemically modified resin. Briefly, the modification process was carried out in two steps, one to hydrolyse the polyester and create hydroxyl and carboxylic acid groups on the surface and other to crosslink the PEG chains. The resulting materials were characterized by contact angle, DSC and FTIR-ATR methods. Additionally, the soil release behavior and the mechanical properties of modified PET were evaluated. For the best process conditions, the treated PET presented 0° contact angle, grade 5 stain release and acceptable mechanical performance.
64Cu-Labeled multifunctional dendrimers for targeted tumor PET imaging.
Ma, Wenhui; Fu, Fanfan; Zhu, Jingyi; Huang, Rui; Zhu, Yizhou; Liu, Zhenwei; Wang, Jing; Conti, Peter S; Shi, Xiangyang; Chen, Kai
2018-03-29
We report the use of multifunctional folic acid (FA)-modified dendrimers as a platform to radiolabel with 64Cu for PET imaging of folate receptor (FR)-expressing tumors. In this study, amine-terminated generation 5 (G5) poly(amidoamine) dendrimers were sequentially modified with fluorescein isothiocyanate (FI), FA, and 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), followed by acetylation of the remaining dendrimer terminal amines. The as-formed multifunctional DOTA-FA-FI-G5·NHAc dendrimers were then radiolabeled with 64Cu via the DOTA chelation. We show that the FA modification renders the dendrimers with targeting specificity to cancer cells overexpressing FR in vitro. Importantly, the radiolabeled 64Cu-DOTA-FA-FI-G5·NHAc dendrimers can be used as a nanoprobe for specific targeting of FR-overexpressing cancer cells in vitro and targeted microPET imaging of the FR-expressing xenografted tumor model in vivo. The developed 64Cu-labeled multifunctional dendrimeric nanoprobe may hold great promise to be used for targeted PET imaging of different types of FR-expressing cancer.
Evaluation of GMI and PMI diffeomorphic‐based demons algorithms for aligning PET and CT Images
Yang, Juan; Zhang, You; Yin, Yong
2015-01-01
Fusion of anatomic information in computed tomography (CT) and functional information in F18‐FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined F18‐FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole‐body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)‐based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point‐wise mutual information (PMI) diffeomorphic‐based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB‐approved study. Whole‐body PET and CT images were acquired from a combined F18‐FDG PET/CT scanner for each patient. The modified Hausdorff distance (dMH) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of dMH were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI‐based demons and the PMI diffeomorphic‐based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined F18‐FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic‐based demons algorithm was more accurate than the GMI‐based demons algorithm in registering PET/CT esophageal images. PACS numbers: 87.57.nj, 87.57. Q‐, 87.57.uk PMID:26218993
Evaluation of GMI and PMI diffeomorphic-based demons algorithms for aligning PET and CT Images.
Yang, Juan; Wang, Hongjun; Zhang, You; Yin, Yong
2015-07-08
Fusion of anatomic information in computed tomography (CT) and functional information in 18F-FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined 18F-FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole-body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)-based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point-wise mutual information (PMI) diffeomorphic-based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB-approved study. Whole-body PET and CT images were acquired from a combined 18F-FDG PET/CT scanner for each patient. The modified Hausdorff distance (d(MH)) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of d(MH) were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI-based demons and the PMI diffeomorphic-based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined 18F-FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic-based demons algorithm was more accurate than the GMI-based demons algorithm in registering PET/CT esophageal images.
Chalaye, Julia; Costentin, Charlotte E; Luciani, Alain; Amaddeo, Giuliana; Ganne-Carrié, Nathalie; Baranes, Laurence; Allaire, Manon; Calderaro, Julien; Azoulay, Daniel; Nahon, Pierre; Seror, Olivier; Mallat, Ariane; Soussan, Michael; Duvoux, Christophe; Itti, Emmanuel; Nault, Jean Charles
2018-03-06
Hepatocellular carcinoma (HCC) staging according to the Barcelona Clinical Liver Cancer (BCLC) classification is based on conventional imaging. The aim of our study was to assess the impact of dual-tracer 18F-fluorocholine and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) on tumor staging and treatment allocation. A total of 192 dual-tracer PET/CT scans (18F-fluorocholine and 18F-fluorodeoxyglucose PET/CT) were performed in 177 patients with HCC. BCLC staging and treatment proposal were retrospectively collected based on conventional imaging, along with any new lesions detected, and changes in BCLC classification or treatment allocation based on dual-tracer PET/CT. Patients were primarily men (87.5%) with cirrhosis (71%) due to alcohol ± non-alcoholic steatohepatitis (26%), viral infection (62%) or unknown causes (12%). Among 122 patients with PET/CT performed for staging, BCLC stage based on conventional imaging was 0/A in 61 patients (50%), B in 32 patients (26%) and C in 29 patients (24%). Dual-tracer PET/CT detected new lesions in 26 patients (21%), upgraded BCLC staging in 14 (11%) and modified treatment strategy in 17 (14%). In addition, dual-tracer PET/CT modified the final treatment in 4/9 (44%) patients with unexplained elevation of alpha-fetoprotein (AFP), 10/25 patients (40%) with doubtful lesions on conventional imaging and 3/36 patients (8%) waiting for liver transplantation without active HCC after tumor response following bridging therapy. When used for HCC staging, dual-tracer PET/CT enabled BCLC upgrading and treatment modification in 11% and 14% of patients, respectively. Dual-tracer PET/CT might also be useful in specific situations (an unexplained rise in AFP, doubtful lesions or pre-transplant evaluation of patients without active HCC). Using a combination of tracers 18F-fluorocholine and 18F-fluorodeoxyglucose when performing positron emission tomography/computed tomography (PET/CT), often called a PET scan, helps to identify new tumor lesions in patients with hepatocellular carcinoma. This technique enabled staging modification of patients' tumors and led to changes in treatment allocation in certain patients. Copyright © 2018. Published by Elsevier B.V.
Reiman, Eric M.; Chen, Kewei; Caselli, Richard J.; Alexander, Gene E.; Bandy, Daniel; Adamson, Jennifer L.; Lee, Wendy; Cannon, Ashley; Stephan, Elizabeth A.; Stephan, Dietrich A.; Papassotiropoulos, Andreas
2008-01-01
We recently implicated a cluster of nine single nucleotide polymorphisms from seven cholesterol-related genes in the risk of Alzheimer’s disease (AD) in a European cohort, and we proposed calculating an aggregate cholesterol-related genetic score (CREGS) to characterize a person’s risk. In a separate study, we found that apolipoprotein E (APOE) ε4 gene dose, an established AD risk factor, was correlated with fluorodeoxyglucose (FDG) positron emission tomography (PET) measurements of hypometabolism in AD-affected brain regions in a cognitively normal American cohort, and we proposed using PET as a presymptomatic endophenotype to help assess putative modifiers of AD risk. Thus, the objective in the present study is to determine whether CREGS is related to PET measurements of hypometabolism in AD-affected brain regions. DNA and PET data from 141 cognitively normal late middle-aged APOE ε4 homozygotes, heterozygotes and non-carriers were analyzed to evaluate the relationship between CREGS and regional PET measurements. Cholesterol-related genetic risk scores were associated with hypometabolism in AD-affected brain regions, even when controlling for the effects of APOE ε4 gene dose. The results support the role of cholesterol-related genes in the predisposition to AD, and support the value of neuroimaging in the presymptomatic assessment of putative modifiers of AD risk. PMID:18280754
Rubí, Sebastià; Costes, Nicolas; Heckemann, Rolf A; Bouvard, Sandrine; Hammers, Alexander; Martí Fuster, Berta; Ostrowsky, Karine; Montavont, Alexandra; Jung, Julien; Setoain, Xavier; Catenoix, Hélène; Hino, Keiko; Liger, François; Le Bars, Didier; Ryvlin, Philippe
2013-12-01
Tuberous sclerosis complex (TSC) is often associated with cerebral tubers and medically intractable epilepsy. We reevaluated whether increased uptake of α-[(11) C]methyl-l-tryptophan (AMT) in cerebral tubers is associated with tuber epileptogenicity. We included 12 patients (six male, 4-53 years old) with TSC and refractory seizures who were evaluated for epilepsy surgery in our center, including video-electroencephalographic (EEG) monitoring, fluid-attenuated inversion recovery magnetic resonance imaging (FLAIR MRI), and positron emission tomography (PET) with α-[(11) C]methyl-l-tryptophan (AMT-PET). Nine of these 12 patients also underwent intracerebral EEG recording. AMT uptake in each tuber was visually evaluated on PET coregistered with MRI. An AMT uptake index based on lesional/healthy cortex ratio was also calculated. Sensitivity and specificity values of AMT-PET in the detection of epileptogenic lesions were obtained, using the available electroclinical and neuroimaging evidence as the gold standard for epileptogenicity. A total of 126 tubers were identified. Two of 12 patients demonstrated a tuber with clearly increased AMT uptake, one of whom also showed a subtle increased AMT uptake in another contralateral tuber. Four other patients showed only subtle increased AMT uptake. The only two tubers with clearly increased AMT uptake proved to be epileptogenic based on intracerebral EEG data, whereas none of the tubers associated with subtle increased AMT uptake were involved at ictal onset. In a per-patient approach, this yielded a sensitivity of clearly increased AMT uptake in detecting tuber epileptogenicity of 17% (2/12 patients), whereas the per-lesion sensitivity and specificity were 12% (95% confidence interval [CI]: 3-34%) and 100% (95% CI: 97-100%), respectively. AMT-PET is a specific neuroimaging technique in the identification of epileptogenic tubers in TSC. Despite its low sensitivity, the clinical usefulness of AMT-PET still deserves to be considered according to the challenging complexity of epilepsy surgery in tuberous sclerosis. Wiley Periodicals, Inc. © 2013 International League Against Epilepsy.
Divgi, Chaitanya R.; Uzzo, Robert G.; Gatsonis, Constantine; Bartz, Roman; Treutner, Silke; Yu, Jian Qin; Chen, David; Carrasquillo, Jorge A.; Larson, Steven; Bevan, Paul; Russo, Paul
2013-01-01
Purpose A clinical study to characterize renal masses with positron emission tomography/computed tomography (PET/CT) was undertaken. Patients and Methods This was an open-label multicenter study of iodine-124 (124I) -girentuximab PET/CT in patients with renal masses who were scheduled for resection. PET/CT and contrast-enhanced CT (CECT) of the abdomen were performed 2 to 6 days after intravenous 124I-girentuximab administration and before resection of the renal mass(es). Images were interpreted centrally by three blinded readers for each imaging modality. Tumor histology was determined by a blinded central pathologist. The primary end points—average sensitivity and specificity for clear cell renal cell carcinoma (ccRCC)—were compared between the two modalities. Agreement between and within readers was assessed. Results 124I-girentuximab was well tolerated. In all, 195 patients had complete data sets (histopathologic diagnosis and PET/CT and CECT results) available. The average sensitivity was 86.2% (95% CI, 75.3% to 97.1%) for PET/CT and 75.5% (95% CI, 62.6% to 88.4%) for CECT (P = .023). The average specificity was 85.9% (95% CI, 69.4% to 99.9%) for PET/CT and 46.8% (95% CI, 18.8% to 74.7%) for CECT (P = .005). Inter-reader agreement was high (κ range, 0.87 to 0.92 for PET/CT; 0.67 to 0.76 for CECT), as was intrareader agreement (range, 87% to 100% for PET/CT; 73.7% to 91.3% for CECT). Conclusion This study represents (to the best of our knowledge) the first clinical validation of a molecular imaging biomarker for malignancy. 124I-girentuximab PET/CT can accurately and noninvasively identify ccRCC, with potential utility for designing best management approaches for patients with renal masses. PMID:23213092
NASA Astrophysics Data System (ADS)
Razavizadeh, Mahmoud; Jamshidi, Masoud
2016-08-01
Fiber to rubber adhesion is an important subject in rubber industry. It is well known that surface treatment (i.e. physical, mechanical and chemical) is an effective method to improve interfacial bonding of fibers and/or fabrics to rubbers. UV irradiation is an effective method which has been used to increase fabric-rubber interfacial interactions. In this research UV assisted chemical modification of PET fabrics was used to increase PET to nitrile rubber (NBR) adhesion. Nitrile rubber is a perfect selection as fuel and oil resistant rubber. However it has weak bonding to PET fabric. For this purpose PET fabric was carboxylated under UV irradiation and then methylenediphenyl diisocyanate (MDI) was grafted on carboxylated PET. The chemical composition of the fabric before and after surface treatment was investigated by X-ray photoelectron spectroscopy (XPS). The sectional morphology of the experimental PET fibers and the interface between rubber compound and PET fabric was studied using scanning electron microscope (SEM). The morphology and structure of the product were analyzed by an energy dispersive X-ray spectrometer (EDX). FTIR-ATR and H NMR analysis were used to assess surface modifications on the PET irradiated fabrics.
Okizaki, Atsutaka; Nakayama, Michihiro; Nakajima, Kaori; Takahashi, Koji
2017-12-01
Positron emission tomography (PET) has become a useful and important technique in oncology. However, spatial resolution of PET is not high; therefore, small abnormalities can sometimes be overlooked with PET. To address this problem, we devised a novel algorithm, iterative modified bicubic interpolation method (IMBIM). IMBIM generates high resolution and -contrast image. The purpose of this study was to investigate the utility of IMBIM for clinical FDG positron emission tomography/X-ray computed tomography (PET/CT) imaging.We evaluated PET images from 1435 patients with malignant tumor and compared the contrast (uptake ratio of abnormal lesions to background) in high resolution image with the standard bicubic interpolation method (SBIM) and IMBIM. In addition to the contrast analysis, 340 out of 1435 patients were selected for visual evaluation by nuclear medicine physicians to investigate lesion detectability. Abnormal uptakes on the images were categorized as either absolutely abnormal or equivocal finding.The average of contrast with IMBIM was significantly higher than that with SBIM (P < .001). The improvements were prominent with large matrix sizes and small lesions. SBIM images showed abnormalities in 198 of 340 lesions (58.2%), while IMBIM indicated abnormalities in 312 (91.8%). There was statistically significant improvement in lesion detectability with IMBIM (P < .001).In conclusion, IMBIM generates high-resolution images with improved contrast and, therefore, may facilitate more accurate diagnoses in clinical practice. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Rashid, Ahmed Nafis; Tsuru, Kanji; Ishikawa, Kunio
2015-05-01
Ozone (O3 ) treatment of polyethylene terephthalate (PET) in distilled water was performed in the presence and absence of calcium (Ca(2+) ). PET was oxidized and thus carboxylic and hydroxyl functional groups were introduced on its surface after O3 treatment, regardless of the presence or absence of Ca(2+) . In the case of O3 treatment with Ca(2+) , PET surface was modified with Ca(2+) . Ca(2+) immobilization was confirmed by X-ray photoelectron spectrometric analysis. Hydrophilicity was investigated by measuring contact angles (CA). CA of PET decreased significantly after ozonation. Surface topography of PET before and after ozone treatment was observed by scanning electron microscopy, and showed no morphological changes. In vitro studies showed enhanced rat bone marrow cell responses on the O3 -treated PET surface. Ca(2+) -O3 oxidation at 37°C for 6 h is expected to be an effective method to fabricate PET with good biocompatibility. © 2014 Wiley Periodicals, Inc.
Multi-modality imaging of tumor phenotype and response to therapy
NASA Astrophysics Data System (ADS)
Nyflot, Matthew J.
2011-12-01
Imaging and radiation oncology have historically been closely linked. However, the vast majority of techniques used in the clinic involve anatomical imaging. Biological imaging offers the potential for innovation in the areas of cancer diagnosis and staging, radiotherapy target definition, and treatment response assessment. Some relevant imaging techniques are FDG PET (for imaging cellular metabolism), FLT PET (proliferation), CuATSM PET (hypoxia), and contrast-enhanced CT (vasculature and perfusion). Here, a technique for quantitative spatial correlation of tumor phenotype is presented for FDG PET, FLT PET, and CuATSM PET images. Additionally, multimodality imaging of treatment response with FLT PET, CuATSM, and dynamic contrast-enhanced CT is presented, in a trial of patients receiving an antiangiogenic agent (Avastin) combined with cisplatin and radiotherapy. Results are also presented for translational applications in animal models, including quantitative assessment of proliferative response to cetuximab with FLT PET and quantification of vascular volume with a blood-pool contrast agent (Fenestra). These techniques have clear applications to radiobiological research and optimized treatment strategies, and may eventually be used for personalized therapy for patients.
Pet ownership and adolescent health: cross-sectional population study.
Mathers, Megan; Canterford, Louise; Olds, Tim; Waters, Elizabeth; Wake, Melissa
2010-12-01
To determine whether adolescent health and well-being are associated with having a pet in the household (any pet, or specifically dogs, cats or horses/ponies) or average daily time spent caring for/playing with pet(s). Design, setting and participants--Cross-sectional data from the third wave of the Health of Young Victorians Study (HOYVS), a school-based population study in Victoria, Australia. Predictors--Adolescent-reported pet ownership and average daily time spent caring for/playing with pet(s). Outcomes--Self-reported quality of life (KIDSCREEN); average 4-day daily physical activity level from a computerised diary; parent-proxy and self-reported physical and psychosocial health status (PedsQL); measured BMI status (not overweight, overweight, obese) and blood pressure. Statistical Analysis--Regression methods, adjusted for socio-demographic factors, and non-parametric methods. Household pet data were available for 928 adolescents (466 boys; mean age of 15.9 (SD 1.2) years). Most adolescents (88.7%) reported having a pet in their household. Of these, 75.1% reported no activity involving pets over the surveyed days. It appeared that neither owning a pet nor time spent caring for/playing with a pet was related, positively or negatively, to adolescent health or well-being. Despite high rates of pet ownership, adolescents had little interaction with pets. It appears that owning a pet and time spent caring for/playing with a pet was not clearly associated with adolescents' health or well-being. © 2010 The Authors. Journal of Paediatrics and Child Health © 2010 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Toledo, Jon B; Bjerke, Maria; Da, Xiao; Landau, Susan M; Foster, Norman L; Jagust, William; Jack, Clifford; Weiner, Michael; Davatzikos, Christos; Shaw, Leslie M; Trojanowski, John Q
2015-05-01
Cerebrospinal fluid (CSF) and positron emission tomographic (PET) amyloid biomarkers have been proposed for the detection of Alzheimer disease (AD) pathology in living patients and for the tracking of longitudinal changes, but the relation between biomarkers needs further study. To determine the association between CSF and PET amyloid biomarkers (cross-sectional and longitudinal measures) and compare the cutoffs for these measures. Longitudinal clinical cohort study from 2005 to 2014 including 820 participants with at least 1 florbetapir F-18 (hereafter referred to as simply florbetapir)-PET scan and at least 1 CSF β-amyloid 1-42 (Aβ1-42) sample obtained within 30 days of each other (501 participants had a second PET scan after 2 years, including 150 participants with CSF Aβ1-42 measurements). Data were obtained from the Alzheimer's Disease Neuroimaging Initiative database. Four different PET scans processing pipelines from 2 different laboratories were compared. The PET cutoff values were established using a mixture-modeling approach, and different mathematical models were applied to define the association between CSF and PET amyloid measures. The values of the CSF Aβ1-42 samples and florbetapir-PET scans showed a nonlinear association (R2 = 0.48-0.66), with the strongest association for values in the middle range. The presence of a larger dynamic range of florbetapir-PET scan values in the higher range compared with the CSF Aβ1-42 plateau explained the differences in correlation with cognition (R2 = 0.36 and R2 = 0.25, respectively). The APOE genotype significantly modified the association between both biomarkers. The PET cutoff values derived from an unsupervised classifier converged with previous PET cutoff values and the established CSF Aβ1-42 cutoff levels. There was no association between longitudinal Aβ1-42 levels and standardized uptake value ratios during follow-up. The association between both biomarkers is limited to a middle range of values, is modified by the APOE genotype, and is absent for longitudinal changes; 4 different approaches in 2 different platforms converge on similar pathological Aβ cutoff levels; and different pipelines to process PET scans showed correlated but not identical results. Our findings suggest that both biomarkers measure different aspects of AD Aβ pathology.
NUT Midline Carcinoma in Elderly Patients: Usefulness of 18F-FDG PET/CT for Treatment Assessment.
Kawase, Takatsugu; Naka, Go; Kubota, Kazuo; Sakashita, Baku; Takeda, Yuichiro
2015-09-01
Nuclear protein in testis (NUT) midline carcinoma is a rare disease that generally arises in adolescents and young adults. However, we encountered a rare NUT midline carcinoma case in an elderly patient. F-2-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT) studies were performed before and during the treatment course. In this case, the initial PET/CT study revealed locoregional hypermetabolism in the mediastinal lesion. After then, the interim PET/CT study indicated a clear diminishing response to the initial treatment, whereas the residual masses were morphologically observable. Nuclear imaging may allow visualization of the therapeutic effect of antineoplastic therapies in both young and elderly patients.
Imaging Alzheimer's disease pathophysiology with PET
Schilling, Lucas Porcello; Zimmer, Eduardo R.; Shin, Monica; Leuzy, Antoine; Pascoal, Tharick A.; Benedet, Andréa L.; Borelli, Wyllians Vendramini; Palmini, André; Gauthier, Serge; Rosa-Neto, Pedro
2016-01-01
ABSTRACT Alzheimer's disease (AD) has been reconceptualised as a dynamic pathophysiological process characterized by preclinical, mild cognitive impairment (MCI), and dementia stages. Positron emission tomography (PET) associated with various molecular imaging agents reveals numerous aspects of dementia pathophysiology, such as brain amyloidosis, tau accumulation, neuroreceptor changes, metabolism abnormalities and neuroinflammation in dementia patients. In the context of a growing shift toward presymptomatic early diagnosis and disease-modifying interventions, PET molecular imaging agents provide an unprecedented means of quantifying the AD pathophysiological process, monitoring disease progression, ascertaining whether therapies engage their respective brain molecular targets, as well as quantifying pharmacological responses. In the present study, we highlight the most important contributions of PET in describing brain molecular abnormalities in AD. PMID:29213438
NASA Astrophysics Data System (ADS)
Davis, Paul B.; Abidi, Mongi A.
1989-05-01
PET is the only imaging modality that provides doctors with early analytic and quantitative biochemical assessment and precise localization of pathology. In PET images, boundary information as well as local pixel intensity are both crucial for manual and/or automated feature tracing, extraction, and identification. Unfortunately, the present PET technology does not provide the necessary image quality from which such precise analytic and quantitative measurements can be made. PET images suffer from significantly high levels of radial noise present in the form of streaks caused by the inexactness of the models used in image reconstruction. In this paper, our objective is to model PET noise and remove it without altering dominant features in the image. The ultimate goal here is to enhance these dominant features to allow for automatic computer interpretation and classification of PET images by developing techniques that take into consideration PET signal characteristics, data collection, and data reconstruction. We have modeled the noise steaks in PET images in both rectangular and polar representations and have shown both analytically and through computer simulation that it exhibits consistent mapping patterns. A class of filters was designed and applied successfully. Visual inspection of the filtered images show clear enhancement over the original images.
Jimenez-Jimenez, E; Mateos, P; Aymar, N; Roncero, R; Ortiz, I; Gimenez, M; Pardo, J; Salinas, J; Sabater, S
2018-05-02
Evidence supporting the use of 18F-FDG-PET/CT in the segmentation process of oesophageal cancer for radiotherapy planning is limited. Our aim was to compare the volumes and tumour lengths defined by fused PET/CT vs. CT simulation. Twenty-nine patients were analyzed. All patients underwent a single PET/CT simulation scan. Two separate GTVs were defined: one based on CT data alone and another based on fused PET/CT data. Volume sizes for both data sets were compared and the spatial overlap was assessed by the Dice similarity coefficient (DSC). The gross tumour volume (GTVtumour) and maximum tumour diameter were greater by PET/CT, and length of primary tumour was greater by CT, but differences were not statistically significant. However, the gross node volume (GTVnode) was significantly greater by PET/CT. The DSC analysis showed excellent agreement for GTVtumour, 0.72, but was very low for GTVnode, 0.25. Our study shows that the volume definition by PET/CT and CT data differs. CT simulation, without taking into account PET/CT information, might leave cancer-involved nodes out of the radiotherapy-delineated volumes.
NASA Astrophysics Data System (ADS)
Dávila, H. Olaya; Sevilla, A. C.; Castro, H. F.; Martínez, S. A.
2016-07-01
Using the Geant4 based simulation framework SciFW1, a detailed simulation was performed for a detector array in the hybrid tomography prototype for small animals called ClearPET / XPAD, which was built in the Centre de Physique des Particules de Marseille. The detector system consists of an array of phoswich scintillation detectors: LSO (Lutetium Oxy-ortosilicate doped with cerium Lu2SiO5:Ce) and LuYAP (Lutetium Ortoaluminate of Yttrium doped with cerium Lu0.7Y0.3AlO3:Ce) for Positron Emission Tomography (PET) and hybrid pixel detector XPAD for Computed Tomography (CT). Simultaneous acquisition of deposited energy and the corresponding time - position for each recorded event were analyzed, independently, for both detectors. interference between detection modules for PET and CT. Information about amount of radiation reaching each phoswich crystal and XPAD detector using a phantom in order to study the effectiveness by radiation attenuation and influence the positioning of the radioactive source 22Na was obtained. The simulation proposed will improve distribution of detectors rings and interference values will be taken into account in the new versions of detectors.
Multimodality PET/MRI agents targeted to activated macrophages.
Tu, Chuqiao; Ng, Thomas S C; Jacobs, Russell E; Louie, Angelique Y
2014-02-01
The recent emergence of multimodality imaging, particularly the combination of PET and MRI, has led to excitement over the prospect of improving detection of disease. Iron oxide nanoparticles have become a popular platform for the fabrication of PET/MRI probes owing to their advantages of high MRI detection sensitivity, biocompatibility, and biodegradability. In this article, we report the synthesis of dextran-coated iron oxide nanoparticles (DIO) labeled with the positron emitter (64)Cu to generate a PET/MRI probe, and modified with maleic anhydride to increase the negative surface charge. The modified nanoparticulate PET/MRI probe (MDIO-(64)Cu-DOTA) bears repetitive anionic charges on the surface that facilitate recognition by scavenger receptor type A (SR-A), a ligand receptor found on activated macrophages but not on normal vessel walls. MDIO-(64)Cu-DOTA has an average iron oxide core size of 7-8 nm, an average hydrodynamic diameter of 62.7 nm, an r1 relaxivity of 16.8 mM(-1) s(-1), and an r 2 relaxivity of 83.9 mM(-1) s(-1) (37 °C, 1.4 T). Cell studies confirmed that the probe was nontoxic and was specifically taken up by macrophages via SR-A. In comparison with the nonmodified analog, the accumulation of MDIO in macrophages was substantially improved. These characteristics demonstrate the promise of MDIO-(64)Cu-DOTA for identification of vulnerable atherosclerotic plaques via the targeting of macrophages.
Shi, Kuangyu; Bayer, Christine; Gaertner, Florian C; Astner, Sabrina T; Wilkens, Jan J; Nüsslin, Fridtjof; Vaupel, Peter; Ziegler, Sibylle I
2017-02-01
Positron-emission tomography (PET) with hypoxia specific tracers provides a noninvasive method to assess the tumor oxygenation status. Reaction-diffusion models have advantages in revealing the quantitative relation between in vivo imaging and the tumor microenvironment. However, there is no quantitative comparison of the simulation results with the real PET measurements yet. The lack of experimental support hampers further applications of computational simulation models. This study aims to compare the simulation results with a preclinical [ 18 F]FMISO PET study and to optimize the reaction-diffusion model accordingly. Nude mice with xenografted human squamous cell carcinomas (CAL33) were investigated with a 2 h dynamic [ 18 F]FMISO PET followed by immunofluorescence staining using the hypoxia marker pimonidazole and the endothelium marker CD 31. A large data pool of tumor time-activity curves (TAC) was simulated for each mouse by feeding the arterial input function (AIF) extracted from experiments into the model with different configurations of the tumor microenvironment. A measured TAC was considered to match a simulated TAC when the difference metric was below a certain, noise-dependent threshold. As an extension to the well-established Kelly model, a flow-limited oxygen-dependent (FLOD) model was developed to improve the matching between measurements and simulations. The matching rate between the simulated TACs of the Kelly model and the mouse PET data ranged from 0 to 28.1% (on average 9.8%). By modifying the Kelly model to an FLOD model, the matching rate between the simulation and the PET measurements could be improved to 41.2-84.8% (on average 64.4%). Using a simulation data pool and a matching strategy, we were able to compare the simulated temporal course of dynamic PET with in vivo measurements. By modifying the Kelly model to a FLOD model, the computational simulation was able to approach the dynamic [ 18 F]FMISO measurements in the investigated tumors.
Yottha Srithep; Alireza Javadi; Srikanth Pilla; Lih-Sheng Turng; Shaoqin Gong; Craig Clemons; Jun Peng
2011-01-01
Poly(ethylene terephthalate) (PET) resin is one of the most widely used thermoplastics, especially in packaging. Because thermal and hydrolytic degradations, recycled PET (RPET) exhibits poor mechanical properties and lacks moldability. The effects of adding elastomeric modifiers, chain extenders (CE), and poly(butylenes adipate-co-terephthalate), PBAT, as a toughener...
NASA Astrophysics Data System (ADS)
Liu, Wendong; Liu, Xueyao; Fangteng, Jiaozi; Wang, Shuli; Fang, Liping; Shen, Huaizhong; Xiang, Siyuan; Sun, Hongchen; Yang, Bai
2014-10-01
This paper presents a facile method to fabricate bioinspired polyethylene terephthalate (PET) nanocone arrays via colloidal lithography. The aspect ratio (AR) of the nanocones can be finely modulated ranging from 1 to 6 by regulating the etching time. The samples with the AR value of 6 can present underwater superoleophobicity with the underwater oil contact angle (OCA) of 171.8°. The as-prepared PET nanocone arrays perform anti-bioadhesion behavior, which inhibits the formation of the actin cytoskeleton when it used as the substrate for cell culture. Moreover, the oil wettability is temperature controlled after modifying the PET nanocone arrays with PNIPAAm film, and the oil wettability of the functionalized nanocone arrays can be transformed from the superoleophobic state with OCA about 151° to the oleophilic state with OCA about 25° reversibly. Due to the high-throughput, parallel fabrication and cost-efficiency of this method, it will be favourable for researchers to introduce oleophobic properties to various substrate and device surfaces. Due to the superoleophobicity and simple functionalizing properties, the PET nanocone arrays are very promising surfaces for anti-adhesion, self-cleaning and have potential applications in material, medical, and biological fields.This paper presents a facile method to fabricate bioinspired polyethylene terephthalate (PET) nanocone arrays via colloidal lithography. The aspect ratio (AR) of the nanocones can be finely modulated ranging from 1 to 6 by regulating the etching time. The samples with the AR value of 6 can present underwater superoleophobicity with the underwater oil contact angle (OCA) of 171.8°. The as-prepared PET nanocone arrays perform anti-bioadhesion behavior, which inhibits the formation of the actin cytoskeleton when it used as the substrate for cell culture. Moreover, the oil wettability is temperature controlled after modifying the PET nanocone arrays with PNIPAAm film, and the oil wettability of the functionalized nanocone arrays can be transformed from the superoleophobic state with OCA about 151° to the oleophilic state with OCA about 25° reversibly. Due to the high-throughput, parallel fabrication and cost-efficiency of this method, it will be favourable for researchers to introduce oleophobic properties to various substrate and device surfaces. Due to the superoleophobicity and simple functionalizing properties, the PET nanocone arrays are very promising surfaces for anti-adhesion, self-cleaning and have potential applications in material, medical, and biological fields. Electronic supplementary information (ESI) available: The optical microscopy image of the self-assembled 2D PS microspheres over a large area, the diameter of the PS microsphere is 580 nm; The top-view SEM image of the PET nanocone arrays over a large area, the AR of the nanocone is 6; The SEM image of the PET nanocone arrays obtained after 30 min etching; The optical image of the water droplet on the PET nanocone arrays with an AR of 6; The schematic illustration of the nanocone arrays modification with PNIPAAm; High resolution XPS spectra of the PNIPAAm modified PET nanocone arrays. See DOI: 10.1039/c4nr04471a
Supercritical methanol for polyethylene terephthalate depolymerization: Observation using simulator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Genta, Minoru; Iwaya, Tomoko; Sasaki, Mitsuru
2007-07-01
To apply PET depolymerization in supercritical methanol to commercial recycling, the benefits of supercritical methanol usage in PET depolymerization was investigated from the viewpoint of the reaction rate and energy demands. PET was depolymerized in a batch reactor at 573 K in supercritical methanol under 14.7 MPa and in vapor methanol under 0.98 MPa in our previous work. The main products of both reactions were the PET monomers of dimethyl terephthalate (DMT) and ethylene glycol (EG). The rate of PET depolymerization in supercritical methanol was faster than that of PET depolymerization in vapor methanol. This indicates supercritical fluid is beneficialmore » in reducing reaction time without the use of a catalyst. We depicted the simple process flow of PET depolymerization in supercritical methanol and in vapor methanol, and by simulation evaluated the total heat demand of each process. In this simulation, bis-hydroxyethyl terephthalate (BHET) was used as a model component of PET. The total heat demand of PET depolymerization in supercritical methanol was 2.35 x 10{sup 6} kJ/kmol Produced-DMT. That of PET depolymerization in vapor methanol was 2.84 x 10{sup 6} kJ/kmol Produced-DMT. The smaller total heat demand of PET depolymerization in supercritical methanol clearly reveals the advantage of using supercritical fluid in terms of energy savings.« less
Siddique, Musib; Frost, Michelle L; Moore, Amelia E B; Fogelman, Ignac; Blake, Glen M
2014-03-01
The aim of the study was to examine whether (18)F-fluoride PET ((18)F-PET) static scan measurements of bone plasma clearance (Ki) can be corrected for tracer efflux from bone from the time of injection. The efflux of tracer from bone mineral to plasma was described by a first-order rate constant kloss. A modified Patlak analysis was applied to 60-min dynamic (18)F-PET scans of the spine and hip acquired during trials on the bone anabolic agent teriparatide to find the best-fit values of kloss at the lumbar spine, total hip and femoral shaft. The resulting values of kloss were used to extrapolate the modified Patlak plots to 120 min after injection and derive a sequence of static scan estimates of Ki at 4-min intervals that were compared with the Patlak Ki values from the 60-min dynamic scans. A comparison was made with the results of the standard static scan analysis, which assumes kloss=0. The best-fit values of kloss for the spine and hip regions of interest averaged 0.006/min and did not change when patients were treated with teriparatide. Static scan values of Ki calculated using the modified analysis with kloss=0.006/min were independent of time between 10 and 120 min after injection and were in close agreement with findings from the dynamic scans. In contrast, by 2 h after injection the static scan Ki values calculated using the standard analysis underestimated the dynamic scan results by 20%. Using a modified analysis that corrects for F efflux from bone, estimates of Ki from static PET scans can be corrected for time up to 2 h after injection. This simplified approach may obviate the need to perform dynamic scans and hence shorten the scanning procedure for the patient and reduce the cost of studies. It also enables reliable estimates of Ki to be obtained from multiple skeletal sites with a single injection of tracer.
Ictal 18F-FDG PET/MRI in a Patient With Cortical Heterotopia and Focal Epilepsy.
Calabria, Ferdinando F; Cascini, Giuseppe Lucio; Gambardella, Antonio; Labate, Angelo; Cherubini, Andrea; Gullà, Domenico; Tafuri, Benedetta; Sabatini, Umberto; Vescio, Virginia; Quattrone, Aldo
2017-10-01
A 19-year-old man with epilepsy underwent ictal F-FDG PET/MRI, showing a 5 mm heterotopic nodule in the periventricular white matter, adjacent to the frontal horn of the left lateral ventricle (SUVmax, 5.5; glucidic cerebral metabolic rate, 0.317 μmol/mL). A repeated F-FDG PET/MRI, during seizure freedom, showed, at visual analysis, subtle decrease of the nodule metabolism. SUVmax and glucidic cerebral metabolic rate were clearly reduced to 3.7 and 0.226, respectively. Ictal F-FDG PET/MRI could be useful in epilepsy because of the added value of SUVmax and cerebral metabolic rate of glucose analysis to understand the relationship between heterotopy and epilepsy.
Freebody, John; Wegner, Eva A; Rossleigh, Monica A
2014-01-01
Positron emission tomography (PET) is a minimally invasive technique which has been well validated for the diagnosis, staging, monitoring of response to therapy, and disease surveillance of adult oncology patients. Traditionally the value of PET and PET/computed tomography (CT) hybrid imaging has been less clearly defined for paediatric oncology. However recent evidence has emerged regarding the diagnostic utility of these modalities, and they are becoming increasingly important tools in the evaluation and monitoring of children with known or suspected malignant disease. Important indications for 2-deoxy-2-(18F)fluoro-D-glucose (FDG) PET in paediatric oncology include lymphoma, brain tumours, sarcoma, neuroblastoma, Langerhans cell histiocytosis, urogenital tumours and neurofibromatosis type I. This article aims to review current evidence for the use of FDG PET and PET/CT in these indications. Attention will also be given to technical and logistical issues, the description of common imaging pitfalls, and dosimetric concerns as they relate to paediatric oncology. PMID:25349660
Potential of PET-MRI for imaging of non-oncologic musculoskeletal disease.
Kogan, Feliks; Fan, Audrey P; Gold, Garry E
2016-12-01
Early detection of musculoskeletal disease leads to improved therapies and patient outcomes, and would benefit greatly from imaging at the cellular and molecular level. As it becomes clear that assessment of multiple tissues and functional processes are often necessary to study the complex pathogenesis of musculoskeletal disorders, the role of multi-modality molecular imaging becomes increasingly important. New positron emission tomography-magnetic resonance imaging (PET-MRI) systems offer to combine high-resolution MRI with simultaneous molecular information from PET to study the multifaceted processes involved in numerous musculoskeletal disorders. In this article, we aim to outline the potential clinical utility of hybrid PET-MRI to these non-oncologic musculoskeletal diseases. We summarize current applications of PET molecular imaging in osteoarthritis (OA), rheumatoid arthritis (RA), metabolic bone diseases and neuropathic peripheral pain. Advanced MRI approaches that reveal biochemical and functional information offer complementary assessment in soft tissues. Additionally, we discuss technical considerations for hybrid PET-MR imaging including MR attenuation correction, workflow, radiation dose, and quantification.
Competitive Advantage of PET/MRI
Jadvar, Hossein; Colletti, Patrick M.
2013-01-01
Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. PMID:23791129
Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI
NASA Astrophysics Data System (ADS)
Harsha Maramraju, Sri; Smith, S. David; Junnarkar, Sachin S.; Schulz, Daniela; Stoll, Sean; Ravindranath, Bosky; Purschke, Martin L.; Rescia, Sergio; Southekal, Sudeepti; Pratte, Jean-François; Vaska, Paul; Woody, Craig L.; Schlyer, David J.
2011-04-01
We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 × 8 array of lutetium oxyorthosilicate crystals (2.22 × 2.22 × 5 mm3) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [11C]raclopride and 2-deoxy-2-[18F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.
Competitive advantage of PET/MRI.
Jadvar, Hossein; Colletti, Patrick M
2014-01-01
Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Utilization of polyethylene terephthalate (PET) in asphalt pavement: A review
NASA Astrophysics Data System (ADS)
Ahmad, A. F.; Razali, A. R.; Razelan, I. S. M.
2017-05-01
The quantity of plastics used throughout the world is increasing every year. Municipal solid wastes (MSW), manufacturing processes and service industries produce a lot of waste plastic materials. The increasing awareness among consumers about the environment has contributed to the concerns over disposal of generated wastes. The growing number of plastic materials every year and limited landfill conditions causes many alternatives exist for the disposal of plastic waste. This paper provides a summary of the study on the utilization of polyethylene terephthalate (PET) in road construction. Data from researcher show that PET can improve some properties of modified asphalt mixture. Having considered the economic and environmental prudent angles, utilization of PET as an additive to asphalt mixture is suitable to be used for road pavement.
Xia, Chenjie; Dickerson, Bradford C
2017-07-01
Biomarkers of the molecular pathology underpinning dementia syndromes are increasingly recognized as crucial for diagnosis and development of disease-modifying treatments. Amyloid PET imaging is an integral part of the diagnostic assessment of Alzheimer disease. Its use has also deepened understanding of the role of amyloid pathology in Lewy body disorders and aging. Tau PET imaging is an imaging biomarker that will likely play an important role in the diagnosis, monitoring, and treatment in dementias. Using tau PET imaging to examine how tau pathology relates to amyloid and other markers of neurodegeneration will serve to better understand the pathophysiologic cascade that leads to dementia. Copyright © 2017 Elsevier Inc. All rights reserved.
Glassner, Mathias; Palmieri, Luca; Monnery, Bryn D; Verbrugghen, Thomas; Deleye, Steven; Stroobants, Sigrid; Staelens, Steven; Wyffels, Leonie; Hoogenboom, Richard
2017-01-09
Poly(2-alkyl-2-oxazoline)s (PAOx) have received increasing interest for biomedical applications. Therefore, it is of fundamental importance to gain an in-depth understanding of the biodistribution profile of PAOx. We report the biodistribution of poly(2-ethyl-2-oxazoline) (PEtOx) with a molar mass of 5 kDa radiolabeled with PET isotopes 89 Zr and 18 F. 18 F-labeled PEtOx is prepared by the strain-promoted azide-alkyne cycloaddition (SPAAC) of [ 18 F]fluoroethylazide to bicyclo[6.1.0]non-4-yne (BCN)-functionalized PEtOx as many common labeling strategies were found to be unsuccessful for PEtOx. 89 Zr-labeled PEtOx is prepared using desferrioxamine end-groups as a chelator. Five kDa PEtOx shows a significantly faster blood clearance compared to PEtOx of higher molar mass while uptake in the liver is lower, indicating a minor contribution of the liver in excretion of the 5 kDa PEtOx. While [ 18 F]-PEtOx displays a rapid and efficient clearance from the kidneys, 5 kDa [ 89 Zr]-Df-PEtOx is not efficiently cleared over the time course of the study, which is most likely caused by trapping of 89 Zr-labeled metabolites in the renal tubules and not the polymer itself, demonstrating the importance of selecting the appropriate label for biodistribution studies.
NASA Astrophysics Data System (ADS)
Park, Jungwoo; Yoo, Ji Wang; Seo, Hee Won; Lee, Youngkwan; Suhr, Jonghwan; Moon, Hyungpil; Koo, Ja Choon; Ryeol Choi, Hyouk; Hunt, Robert; Kim, Kwang Jin; Kim, Soo Hyun; Nam, Jae-Do
2017-03-01
As a new class of thermally activated actuators based on polymeric fibers, we investigated polyethylene terephthalate (PET) yarns for the development of a twisted-coiled polymer fiber actuator (TCA). The PET yarn TCA exhibited the maximum linear actuation up to 8.9% by external heating at above the glass transition temperature, 160 °C-180 °C. The payload of the actuator was successfully correlated with the preload and training-load conditions by an empirical equation. Furthermore, the PET-based TCA was electrically driven by Joule heating after the PET surface was metallization with silver. For the fast and precise control of PET yarn TCA, electroless silver plating was conducted to form electrical conductive layers on the PET fiber surface. The silver plated PET-based TCA was tested by Joule heating and the tensile actuation was increased up to 12.1% (6 V) due to the enhanced surface hardness and slippage of PET fibers. Overall, silver plating of the polymeric yarn provided a fast actuation speed and enhanced actuation performance of the TCA actuator by Joule heating, providing a great potential for being used in artificial muscle for biomimetic machines including robots, industrial actuators and powered exoskeletons.
Ahmadzadehfar, Hojjat; Schlenkhoff, Carl Diedrich; Rogenhofer, Sebastian; Yordanova, Anna; Essler, Markus
2016-09-01
A 64-year-old man with prostate cancer and an increasing prostate-specific antigen (PSA) level under therapy with abiraterone acetate underwent a therapy with Ra. Before the first therapy and 4 weeks after the last cycle, the patient underwent Ga-PSMA PET, which showed a clear response of bone metastases.
Glaudemans, Andor W. J. M.; de Vries, Erik F. J.; Dierckx, Rudi A. J. O.; Slart, Riemer H. J. A.; Signore, Alberto
2013-01-01
FDG-PET, combined with CT, is nowadays getting more and more relevant for the diagnosis of several infectious and inflammatory diseases and particularly for therapy monitoring. Thus, this paper gives special attention to the role of FDG-PET/CT in the diagnosis and therapy monitoring of infectious and inflammatory diseases. Enough evidence in the literature already exists about the usefulness of FDG-PET/CT in the diagnosis, management, and followup of patients with sarcoidosis, spondylodiscitis, and vasculitis. For other diseases, such as inflammatory bowel diseases, rheumatoid arthritis, autoimmune pancreatitis, and fungal infections, hard evidence is lacking, but studies also point out that FDG-PET/CT could be useful. It is of invaluable importance to have large prospective multicenter studies in this field to provide clear answers, not only for the status of nuclear medicine in general but also to reduce high costs of treatment. PMID:24027590
Positron emission tomography to assess hypoxia and perfusion in lung cancer
Verwer, Eline E; Boellaard, Ronald; van der Veldt, Astrid AM
2014-01-01
In lung cancer, tumor hypoxia is a characteristic feature, which is associated with a poor prognosis and resistance to both radiation therapy and chemotherapy. As the development of tumor hypoxia is associated with decreased perfusion, perfusion measurements provide more insight into the relation between hypoxia and perfusion in malignant tumors. Positron emission tomography (PET) is a highly sensitive nuclear imaging technique that is suited for non-invasive in vivo monitoring of dynamic processes including hypoxia and its associated parameter perfusion. The PET technique enables quantitative assessment of hypoxia and perfusion in tumors. To this end, consecutive PET scans can be performed in one scan session. Using different hypoxia tracers, PET imaging may provide insight into the prognostic significance of hypoxia and perfusion in lung cancer. In addition, PET studies may play an important role in various stages of personalized medicine, as these may help to select patients for specific treatments including radiation therapy, hypoxia modifying therapies, and antiangiogenic strategies. In addition, specific PET tracers can be applied for monitoring therapy. The present review provides an overview of the clinical applications of PET to measure hypoxia and perfusion in lung cancer. Available PET tracers and their characteristics as well as the applications of combined hypoxia and perfusion PET imaging are discussed. PMID:25493221
Toledo, Jon B.; Bjerke, Maria; Da, Xiao; Landau, Susan M.; Foster, Norman L; Jagust, William; Jack, Clifford; Weiner, Michael; Davatzikos, Christos; Shaw, Leslie M.; Trojanowski, John Q.
2017-01-01
IMPORTANCE Cerebrospinal fluid (CSF) and positron emission tomographic (PET) amyloid biomarkers have been proposed for the detection of Alzheimer disease (AD) pathology in living patients and for the tracking of longitudinal changes, but the relation between biomarkers needs further study. OBJECTIVE To determine the association between CSF and PET amyloid biomarkers (cross-sectional and longitudinal measures) and compare the cutoffs for these measures. DESIGN, SETTING, AND PARTICIPANTS Longitudinal clinical cohort study from 2005 to 2014 including 820 participants with at least 1 florbetapir F-18 (hereafter referred to as simply florbetapir)–PET scan and at least 1 CSF β-amyloid 1–42 (Aβ1–42) sample obtained within 30 days of each other (501 participants had a second PET scan after 2 years, including 150 participants with CSF Aβ1–42 measurements). Data were obtained from the Alzheimer’s Disease Neuroimaging Initiative database. MAIN OUTCOMES AND MEASURES Four different PET scans processing pipelines from 2 different laboratories were compared. The PET cutoff values were established using a mixture-modeling approach, and different mathematical models were applied to define the association between CSF and PET amyloid measures. RESULTS The values of the CSF Aβ1–42 samples and florbetapir-PET scans showed a nonlinear association (R2 = 0.48–0.66), with the strongest association for values in the middle range. The presence of a larger dynamic range of florbetapir-PET scan values in the higher range compared with the CSF Aβ1–42 plateau explained the differences in correlation with cognition (R2 = 0.36 and R2 = 0.25, respectively). The APOE genotype significantly modified the association between both biomarkers. The PET cutoff values derived from an unsupervised classifier converged with previous PET cutoff values and the established CSF Aβ1–42 cutoff levels. There was no association between longitudinal Aβ1–42 levels and standardized uptake value ratios during follow-up. CONCLUSIONS AND RELEVANCE The association between both biomarkers is limited to a middle range of values, is modified by the APOE genotype, and is absent for longitudinal changes; 4 different approaches in 2 different platforms converge on similar pathological Aβ cutoff levels; and different pipelines to process PET scans showed correlated but not identical results. Our findings suggest that both biomarkers measure different aspects of AD Aβ pathology. PMID:25822737
Salem, A; Salem, A F; Al-Ibraheem, A; Lataifeh, I; Almousa, A; Jaradat, I
2011-01-01
In recent years, the role of positron emission tomography (PET) in the staging and management of gynecological cancers has been increasing. The aim of this study was to systematically review the role of PET in radiotherapy planning and brachytherapy treatment optimization in patients with cervical cancer. Systematic literature review. Systematic review of relevant literature addressing the utilization of PET and/or PET-computed tomography (CT) in external-beam radiotherapy planning and brachytherapy treatment optimization. We performed an extensive PubMed database search on 20 April 2011. Nineteen studies, including 759 patients, formed the basis of this systematic review. PET/ PET-CT is the most sensitive imaging modality for detecting nodal metastases in patients with cervical cancer and has been shown to impact external-beam radiotherapy planning by modifying the treatment field and customizing the radiation dose. This particularly applies to detection of previously uncovered para-aortic and inguinal nodal metastases. Furthermore, PET/ PET-CT guided intensity-modulated radiation therapy (IMRT) allows delivery of higher doses of radiation to the primary tumor, if brachytherapy is unsuitable, and to grossly involved nodal disease while minimizing treatment-related toxicity. PET/ PET-CT based brachytherapy optimization allows improved tumor-volume dose distribution and detailed 3D dosimetric evaluation of risk organs. Sequential PET/ PET-CT imaging performed during the course of brachytherapy form the basis of âadaptiveâ brachytherapy in cervical cancer. This review demonstrates the effectiveness of pretreatment PET/ PET-CT in cervical cancer patients treated by radiotherapy. Further prospective studies are required to define the group of patients who would benefit the most from this procedure.
Ryan, Sara; Ziebland, Sue
2015-01-01
There is mounting evidence that pets are associated with physiological, psychological and social benefits for humans. Much of this research has come from western countries, where there have been consistent calls for greater engagement with pet ownership and health. Drawing on a secondary analysis of 61 in-depth interviews with people, or carers of people, with long-term conditions, we explore how pets feature in people's narrative accounts of their experiences. Our findings demonstrate the multifaceted nature of people's relationships with pets, and the embedded and embodied ways in which human-nonhuman interactions are played out in narratives of chronic illness. Our study differs from other work on pets and health in that, by returning to the interview video recordings, we were able to explore the sometimes three-way interactions, the co(a)gency, between participants, pets and researchers. Pets were often presented as important family members, yet the researchers' responses to the presence or talk about pets was often markedly different from their reactions to other household members. We conclude with cautioning against the downgrading of pets in narrative health research. Narrative approaches may invite participants to talk about what is important to them, yet they clearly have limitations in practice. © 2015 The Authors. Sociology of Health & Illness © 2015 Foundation for the Sociology of Health & Illness/John Wiley & Sons Ltd.
Jiang, Jia; Ai, Chengchong; Zhan, Zufeng; Zhang, Peng; Wan, Fang; Chen, Jun; Hao, Wei; Wang, Yaxian; Yao, Jinrong; Shao, Zhengzhong; Chen, Tianwu; Zhou, Liang; Chen, Shiyi
2016-04-01
Artificial ligaments utilized in reconstruction of anterior cruciate ligament (ACL) are usually made of polyethylene terepthalate (PET) because of its good mechanical properties in vivo. However, it was found that the deficiencies in hydrophilicity and biocompatibility of PET hindered the process of ligamentization. Therefore, surface modification of the PET is deemed as a solution in resolving such problem. Silk fibroin (SF), which is characterized by good biocompatibility and low immunogenicity in clinical applications, was utilized to prepare a coating on the PET ligament (PET+SF) in this work. At first, decrease of hydrophobicity and appearance of amino groups were found on the surface of artificial PET ligament after coating with SF. Second, mouse fibroblasts were cultured on the two different kinds of ligament in order to clarify the possible effect of SF coating. It was proved that mouse fibroblasts display better adhesion and proliferation on PET+SF than PET ligament according to the results of several technical methods including SEM observation, cell adhesive force and spread area test, and mRNA analysis. Meanwhile, methylthiazolyldiphenyl-tetrazolium bromide and DNA content tests showed that biocompatibility of PET+SF is better than PET ligament. In addition, collagen deposition tests also indicated that the quantity of collagen in PET+SF is higher than PET ligament. Based on these results, it can be concluded that SF coating is suggested to be an effective approach to modify the surface of PET ligament and enhance the "ligamentization" process in vivo accordingly. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Brom, Maarten; Joosten, Lieke; Laverman, Peter; Oyen, Wim J G; Béhé, Martin; Gotthardt, Martin; Boerman, Otto C
2011-04-01
In comparison to somatostatin receptor scintigraphy, gastrin receptor scintigraphy using 111In-DTPA-minigastrin (MG0) showed added value in diagnosing neuroendocrine tumors. We investigated whether the 68Ga-labeled gastrin analogue DOTA-MG0 is suited for positron emission tomography (PET), which could improve image quality. Targeting of cholecystokinin-2 (CCK2)/gastrin receptor-positive tumor cells with DOTA-MG0 labeled with either 111In or 68Ga in vitro was investigated using the AR42J rat tumor cell line. Biodistribution was examined in BALB/c nude mice with a subcutaneous AR42J tumor. In vivo PET imaging was performed using a preclinical PET-computed tomographic scanner. DOTA-MG0 showed high receptor affinity in vitro. Biodistribution studies revealed high tumor uptake of 68Ga-DOTA-MG0: 4.4 ± 1.3 %ID/g at 1 hour postinjection. Coadministration of an excess unlabeled peptide blocked the tumor uptake (0.7 ± 0.1 %ID/g), indicating CCK2/gastrin receptor-mediated uptake (p = .0005). The biodistribution of 68Ga-DOTA-MG0 was similar to that of 111In-DOTA-MG0. Subcutaneous and intraperitoneal tumors were clearly visualized by small-animal PET imaging with 5 MBq 68Ga-DOTA-MG0. 111In- and 68Ga-labeled DOTA-MG0 specifically accumulate in CCK2/gastrin receptor-positive AR42J tumors with similar biodistribution apart from the kidneys. AR42J tumors were clearly visualized by microPET. Therefore, 68Ga-DOTA-MG0 is a promising tracer for PET imaging of CCK2/gastrin receptor-positive tumors in humans.
Raina, P; Waltner-Toews, D; Bonnett, B; Woodward, C; Abernathy, T
1999-03-01
To examine whether companion animals or attachment to a companion animal was associated with changes in physical and psychological health in older people and whether the relationships between physical and psychological health and human social networks were modified by the presence or absence of a companion animal. A 1-year longitudinal study with standardized telephone interview data collected at baseline and repeated at 1-year Wellington County, Ontario, Canada An age- and sex stratified random sample (baseline n = 1054; follow-up n = 995) of noninstitutionalized adults aged 65 and older (mean age = 73, SD +/- 6.3) Social Network Activity was measured using a family and non-family social support scale, participation in an organized social group, involvement in the affairs of the social group, the practice of confiding in others, feelings of loneliness, and the perceived presence of support in a crisis situation. Chronic conditions were measured as the current number of selected health problems. Pet ownership was assessed by the report of owning a dog or a cat and the Lexington Attachment to Pets Scale score. Physical health was assessed as the ability to perform Activities of Daily Living (ADLs). Psychological health was measured as a summed score comprising the level of satisfaction regarding one's health, family and friend relationships, job, finances, life in general, overall happiness, and perceived mental health. Sociodemographic variables assessed include subject age, sex, marital status, living arrangements, education, household income, and major life events. Pet owners were younger, currently married or living with someone, and more physically active than non-pet owners. The ADL level of respondents who did not currently own pets deteriorated more on average (beta = -.270, P = .040) than that of respondents who currently owned pets after adjusting for other variables during the 1-year period. No statistically significant direct association was observed between pet ownership and change in psychological well-being (P > .100). However, pet ownership significantly modified the relationship between social support and the change in psychological well-being (P = .001) over a 1-year period. The results demonstrate the benefits of pet ownership in maintaining or slightly enhancing ADL levels of older people. However, a more complex relationship was observed between pet ownership and an older person's well-being.
A small animal PET based on GAPDs and charge signal transmission approach for hybrid PET-MR imaging
NASA Astrophysics Data System (ADS)
Kang, Jihoon; Choi, Yong; Hong, Key Jo; Hu, Wei; Jung, Jin Ho; Huh, Yoonsuk; Kim, Byung-Tae
2011-08-01
Positron emission tomography (PET) employing Geiger-mode avalanche photodiodes (GAPDs) and charge signal transmission approach was developed for small animal imaging. Animal PET contained 16 LYSO and GAPD detector modules that were arranged in a 70 mm diameter ring with an axial field of view of 13 mm. The GAPDs charge output signals were transmitted to a preamplifier located remotely using 300 cm flexible flat cables. The position decoder circuits (PDCs) were used to multiplex the PET signals from 256 to 4 channels. The outputs of the PDCs were digitized and further-processed in the data acquisition unit. The cross-compatibilities of the PET detectors and MRI were assessed outside and inside the MRI. Experimental studies of the developed full ring PET were performed to examine the spatial resolution and sensitivity. Phantom and mouse images were acquired to examine the imaging performance. The mean energy and time resolution of the PET detector were 17.6% and 1.5 ns, respectively. No obvious degradation on PET and MRI was observed during simultaneous PET-MRI data acquisition. The measured spatial resolution and sensitivity at the CFOV were 2.8 mm and 0.7%, respectively. In addition, a 3 mm diameter line source was clearly resolved in the hot-sphere phantom images. The reconstructed transaxial PET images of the mouse brain and tumor displaying the glucose metabolism patterns were imaged well. These results demonstrate GAPD and the charge signal transmission approach can allow the development of high performance small animal PET with improved MR compatibility.
Bacteriophages safely reduce Salmonella contamination in pet food and raw pet food ingredients.
Soffer, Nitzan; Abuladze, Tamar; Woolston, Joelle; Li, Manrong; Hanna, Leigh Farris; Heyse, Serena; Charbonneau, Duane; Sulakvelidze, Alexander
2016-01-01
Contamination of pet food with Salmonella is a serious public health concern, and several disease outbreaks have recently occurred due to human exposure to Salmonella tainted pet food. The problem is especially challenging for raw pet foods (which include raw meats, seafood, fruits, and vegetables). These foods are becoming increasingly popular because of their nutritional qualities, but they are also more difficult to maintain Salmonella -free because they lack heat-treatment. Among various methods examined to improve the safety of pet foods (including raw pet food), one intriguing approach is to use bacteriophages to specifically kill Salmonella serotypes. At least 2 phage preparations (SalmoFresh® and Salmonelex™) targeting Salmonella are already FDA cleared for commercial applications to improve the safety of human foods. However, similar preparations are not yet available for pet food applications. Here, we report the results of evaluating one such preparation (SalmoLyse®) in reducing Salmonella levels in various raw pet food ingredients (chicken, tuna, turkey, cantaloupe, and lettuce). Application of SalmoLyse® in low (ca. 2-4×10 6 PFU/g) and standard (ca. 9×10 6 PFU/g) concentrations significantly ( P < 0.01) reduced (by 60-92%) Salmonella contamination in all raw foods examined compared to control treatments. When SalmoLyse®-treated (ca. 2×10 7 PFU/g) dry pet food was fed to cats and dogs, it did not trigger any deleterious side effects in the pets. Our data suggest that the bacteriophage cocktail lytic for Salmonella can significantly and safely reduce Salmonella contamination in various raw pet food ingredients.
Bacteriophages safely reduce Salmonella contamination in pet food and raw pet food ingredients
Soffer, Nitzan; Abuladze, Tamar; Woolston, Joelle; Li, Manrong; Hanna, Leigh Farris; Heyse, Serena; Charbonneau, Duane; Sulakvelidze, Alexander
2016-01-01
ABSTRACT Contamination of pet food with Salmonella is a serious public health concern, and several disease outbreaks have recently occurred due to human exposure to Salmonella tainted pet food. The problem is especially challenging for raw pet foods (which include raw meats, seafood, fruits, and vegetables). These foods are becoming increasingly popular because of their nutritional qualities, but they are also more difficult to maintain Salmonella-free because they lack heat-treatment. Among various methods examined to improve the safety of pet foods (including raw pet food), one intriguing approach is to use bacteriophages to specifically kill Salmonella serotypes. At least 2 phage preparations (SalmoFresh® and Salmonelex™) targeting Salmonella are already FDA cleared for commercial applications to improve the safety of human foods. However, similar preparations are not yet available for pet food applications. Here, we report the results of evaluating one such preparation (SalmoLyse®) in reducing Salmonella levels in various raw pet food ingredients (chicken, tuna, turkey, cantaloupe, and lettuce). Application of SalmoLyse® in low (ca. 2–4×106 PFU/g) and standard (ca. 9×106 PFU/g) concentrations significantly (P < 0.01) reduced (by 60–92%) Salmonella contamination in all raw foods examined compared to control treatments. When SalmoLyse®-treated (ca. 2×107 PFU/g) dry pet food was fed to cats and dogs, it did not trigger any deleterious side effects in the pets. Our data suggest that the bacteriophage cocktail lytic for Salmonella can significantly and safely reduce Salmonella contamination in various raw pet food ingredients. PMID:27738557
Merrill, David A.; Siddarth, Prabha; Raji, Cyrus A.; Emerson, Natacha D.; Rueda, Florangel; Ercoli, Linda M.; Miller, Karen J.; Lavretsky, Helen; Harris, Laurel M.; Burggren, Alison C.; Bookheimer, Susan Y.; Barrio, Jorge R.; Small, Gary W.
2016-01-01
Objective Exercise and diet impact body composition, but their age-related brain effects are unclear at the molecular imaging level. To address these issues, we determined whether body mass index (BMI), physical activity, and diet relate to brain positron emission tomography (PET) of amyloid plaques and tau tangles using 2-(1-(6-[(2-[F-18]fluoroethyl)(methyl)amino]-2-naphthyl)ethylidene)malononitrile (FDDNP). Methods Volunteers (n = 44, mean age = 62.6 ± 10.7 years) with subjective memory impairment (n = 24) or mild cognitive impairment (MCI; n = 20) were recruited by soliciting for memory complaints. Levels of physical activity and extent of following a Mediterranean-type diet were self-reported. FDDNP-PET scans assessed plaque/tangle binding in Alzheimer’s disease (AD)-associated regions (frontal, parietal, medial and lateral temporal, posterior cingulate). Mixed models controlling for known covariates examined BMI, physical activity, and diet in relation to FDDNP-PET. Results MCI subjects with above normal BMI (>25) had higher FDDNP-PET binding compared to those with normal BMI (1.11(.03) vs 1.08(.03), ES=1.04, t(35)=3.3, p=.002). Greater physical activity was associated with lower FDDNP-PET binding in MCI subjects (1.07(.03) vs 1.11(.03), ES=1.13, t(35) =−3.1, p=.004) but not in subjects with subjective memory impairment (1.07 (.03) vs 1.07(.03), ES=.02, t(35)=−0.1, p=.9). Healthier diet related to lower FDDNP-PET binding, regardless of cognitive status (1.07(.03) vs 1.09(.02), ES=0.72, t(35)=−2.1, p = .04). Conclusion and Relevance These preliminary findings are consistent with a relationship between risk modifiers and brain plaque/tangle deposition in non-demented individuals and supports maintenance of normal body weight, regular physical activity, and healthy diet adherence to protect the brain during aging. PMID:27421618
A Survey of FDG- and Amyloid-PET Imaging in Dementia and GRADE Analysis
Daniela, Perani; Orazio, Schillaci; Alessandro, Padovani; Mariano, Nobili Flavio; Leonardo, Iaccarino; Pasquale Anthony, Della Rosa; Giovanni, Frisoni; Carlo, Caltagirone
2014-01-01
PET based tools can improve the early diagnosis of Alzheimer's disease (AD) and differential diagnosis of dementia. The importance of identifying individuals at risk of developing dementia among people with subjective cognitive complaints or mild cognitive impairment has clinical, social, and therapeutic implications. Within the two major classes of AD biomarkers currently identified, that is, markers of pathology and neurodegeneration, amyloid- and FDG-PET imaging represent decisive tools for their measurement. As a consequence, the PET tools have been recognized to be of crucial value in the recent guidelines for the early diagnosis of AD and other dementia conditions. The references based recommendations, however, include large PET imaging literature based on visual methods that greatly reduces sensitivity and specificity and lacks a clear cut-off between normal and pathological findings. PET imaging can be assessed using parametric or voxel-wise analyses by comparing the subject's scan with a normative data set, significantly increasing the diagnostic accuracy. This paper is a survey of the relevant literature on FDG and amyloid-PET imaging aimed at providing the value of quantification for the early and differential diagnosis of AD. This allowed a meta-analysis and GRADE analysis revealing high values for PET imaging that might be useful in considering recommendations. PMID:24772437
Avramovic, Nemanja; Weckesser, Matthias; Velasco, Aglaé; Stenner, Markus; Noto, Benjamin
2017-02-01
A 60-year-old woman was referred to contrast-enhanced CT for evaluation of jugular vein thrombosis incidentally detected by ultrasound. Contrast-enhanced CT showed an enhanced tumor of the right skull base highly suspicious of jugulotympanic paraganglioma. However, the jugular veins showed a nearly symmetric contrast enhancement without clear evidence of thrombosis. Consecutive Ga-DOTATATE PET/CT depicted high tumor uptake, which comprised the entire internal jugular vein. Endovascular growth of paraganglioma might be missed on contrast-enhanced CT because of high vascularization of the lesion. Ga-DOTATATE PET is suited for accurate determination of tumor extent.
Contribution of positron emission tomography in pleural disease.
Duysinx, B; Corhay, J-L; Larock, M-P; Withofs, N; Bury, T; Hustinx, R; Louis, R
2010-10-01
Positron emission tomography (PET) now plays a clear role in oncology, especially in chest tumours. We discuss the value of metabolic imaging in characterising pleural pathology in the light of our own experience and review the literature. PET is particularly useful in characterising malignant pleural pathologies and is a factor of prognosis in mesothelioma. Metabolic imaging also provides clinical information for staging lung cancer, in researching the primary tumour in metastatic pleurisy and in monitoring chronic or recurrent pleural pathologies. PET should therefore be considered as a useful tool in the diagnosis of liquid or solid pleural pathologies. Copyright © 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.
Gong, Kuang; Yang, Jaewon; Kim, Kyungsang; El Fakhri, Georges; Seo, Youngho; Li, Quanzheng
2018-05-23
Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR hybrid systems, PET attenuation is challenging as Magnetic Resonance (MR) images do not reflect attenuation coefficients directly. To address this issue, we present deep neural network methods to derive the continuous attenuation coefficients for brain PET imaging from MR images. With only Dixon MR images as the network input, the existing U-net structure was adopted and analysis using forty patient data sets shows it is superior than other Dixon based methods. When both Dixon and zero echo time (ZTE) images are available, we have proposed a modified U-net structure, named GroupU-net, to efficiently make use of both Dixon and ZTE information through group convolution modules when the network goes deeper. Quantitative analysis based on fourteen real patient data sets demonstrates that both network approaches can perform better than the standard methods, and the proposed network structure can further reduce the PET quantification error compared to the U-net structure. © 2018 Institute of Physics and Engineering in Medicine.
NASA Astrophysics Data System (ADS)
Gisario, Annamaria; Veniali, Francesco; Barletta, Massimiliano; Tagliaferri, Vincenzo; Vesco, Silvia
2017-03-01
Joining of Poly(Ethylene Terephthalate) PET and its biodegradable derivatives is of high relevance to ensure good productive rate, low cost and operational safety for fabrication of medical and electronic devices, sport equipments as well as for manufacturing of food and drug packaging solutions. In the present investigation, granules of PET and PETs modified by organic additives, which promote biodegradation of the polymeric chains, were prepared by extrusion compounding. The achieved granules were subsequently re-extruded to shape thin (330 μm) flat sheets. Substrates cut from these sheets were joined by Laser Transmission Welding (LTW) with a continuous wave High Power Diode Laser (cw-HPDL). First, based on a qualitative evaluation of the welded joints, the most suitable operational windows for PETs laser joining were identified. Second, characterization of the mechanical properties of the welded joints was performed by tensile tests. Accordingly, Young's modulus of PET and biodegradable PET blends was studied by Takayanagi's model and, based on the experimental results, a novel predicting analytical model derived from the mixture rule was developed. Lastly, material degradation of the polymeric joints was evaluated by FT-IR analysis, thus allowing to identify the main routes to thermal degradation of PET and, especially, of biodegradable PET blends during laser processing.
Marin, Clara; Vega, Santiago; Marco-Jiménez, Francisco
2016-07-01
Turtles may be considered unsafe pets, particularly in households with children. This study aimed to assess Salmonella carriage by turtles in pet stores and in private ownership to inform the public of the potential health risk, enabling informed choices around pet selection. During the period between September and October 2013, 24 pet stores and 96 private owners were sampled in the Valencian Region (Eastern Spain). Salmonella identification procedure was based on ISO 6579: 2002 recommendations (Annex D). Salmonella strains were serotyped in accordance with Kauffman-White-Le-Minor technique. The rate of isolation of Salmonella was very high from pet store samples (75.0% ± 8.8%) and moderate for private owners (29.0% ± 4.6%). Serotyping revealed 18 different serotypes among two Salmonella enterica subspecies: S. enterica subsp. enterica and S. enterica subsp. diarizonae. Most frequently isolated serotypes were Salmonella Typhimurium (39.5%, 17/43) and Salmonella Pomona (9.3%, 4/43). Serotypes identified have previously been reported in turtles, and child Salmonella infections associate with pet turtle exposure. The present study clearly demonstrates that turtles in pet stores, as well as in private owners, could be a direct or indirect source of a high risk of human Salmonella infections. In addition, pet stores should advise their customers of the potential risks associated with reptile ownership.
Lin, Xiuyi; Yu, Jing; Li, Hedong; Lam, Jeffery Y K; Shih, Kaimin; Sham, Ivan M L; Leung, Christopher K Y
2018-05-26
As an important portion of the total plastic waste bulk but lack of reuse and recycling, the enormous amounts of polyethylene terephthalate (PET) solid wastes have led to serious environmental issues. This study explores the feasibility of recycling PET solid wastes as short fibers in Strain-Hardening Cementitious Composites (SHCCs), which exhibit strain-hardening and multiple cracking under tension, and therefore have clear advantages over conventional concrete for many construction applications. Based on micromechanical modeling, fiber dispersion and alkali resistance, the size of recycled PET fibers was first determined. Then the hydrophobic PET surface was treated with NaOH solution followed by a silane coupling agent to achieve the dual purpose of improving the fiber/matrix interfacial frictional bond (from 0.64 MPa to 0.80 MPa) and enhancing the alkali resistance for applications in alkaline cementitious environment. With surface treatment, recycling PET wastes as fibers in SHCCs is a promising approach to significantly reduce the material cost of SHCCs while disposing hazardous PET wastes in construction industry. Copyright © 2018 Elsevier B.V. All rights reserved.
PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation
NASA Astrophysics Data System (ADS)
España, S; Herraiz, J L; Vicente, E; Vaquero, J J; Desco, M; Udias, J M
2009-03-01
Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.
Photophysical and photochemical effects of UV and VUV photo-oxidation and photolysis on PET and PEN
NASA Astrophysics Data System (ADS)
Morgan, Andrew
Polyethylene Terephthalate (PET) is a widely used polymer in the bottling, packaging, and clothing industry. In recent years an increasing global demand for PET has taken place due to the Solar Disinfection (SODIS) process. SODIS is a method of sterilizing fresh water into drinkable water. The PET bottles are used in the process to contain the water during solar irradiation due to its highly transparent optical property. Alongside PET, polyethylene 2,6-napthalate (PEN) is used in bottling and flexible electronic applications. The surface of PEN would need to be modified to control the hydrophilicity and the interaction it exudes as a substrate. The UV light absorption properties of PET and PEN are of great importance for many applications, and thus needs to be studied along with its photochemical resistance. The optical and chemical nature of PET was studied as it was treated by UV photo-oxidation, photo-ozonation, and photolysis under atmospheric pressure. Another investigation was also used to study PEN and PET as they are treated by vacuum UV (VUV) photo-oxidation, VUV photolysis, and remote oxygen reactions. The extent of the photoreactions' effect into the depth of the polymers is examined as treatment conditions are changed. The different experimental methods established the rate of several competing photoreactions on PET and PEN during irradiance, and their effect on the optical quality of the polymers.
18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.
Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S
2017-02-01
This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.
Use of Fc-Engineered Antibodies as Clearing Agents to Increase Contrast During PET
Swiercz, Rafal; Chiguru, Srinivas; Tahmasbi, Amir; Ramezani, Saleh M.; Hao, Guiyang; Challa, Dilip K.; Lewis, Matthew A.; Kulkarni, Padmakar V.; Sun, Xiankai; Ober, Raimund J.; Mason, Ralph P.; Ward, E. Sally
2015-01-01
Despite promise for the use of antibodies as molecular imaging agents in PET, their long in vivo half-lives result in poor contrast and radiation damage to normal tissue. This study describes an approach to overcome these limitations. Methods Mice bearing human epidermal growth factor receptor type 2 (HER2)–overexpressing tumors were injected with radiolabeled (124I, 125I) HER2-specific antibody (pertuzumab). Pertuzumab injection was followed 8 h later by the delivery of an engineered, antibody-based inhibitor of the receptor, FcRn. Biodistribution analyses and PET were performed at 24 and 48 h after pertuzumab injection. Results The delivery of the engineered, antibody-based FcRn inhibitor (or Abdeg, for antibody that enhances IgG degradation) results in improved tumor-to-blood ratios, reduced systemic exposure to radiolabel, and increased contrast during PET. Conclusion Abdegs have considerable potential as agents to stringently regulate antibody dynamics in vivo, resulting in increased contrast during molecular imaging with PET. PMID:24868106
Flexible inverted polymer solar cells fabricated in air at low temperatures
NASA Astrophysics Data System (ADS)
Kuwabara, Takayuki; Wang, Xiaofan; Kusumi, Takuji; Yamaguchi, Takahiro; Taima, Tetsuya; Takahashi, Kohshin
2016-08-01
A series of modified indium tin oxide (ITO) materials, including sol-gel zinc-oxide-coated ITO (ITO/ZnO), ZnO nanoparticle-coated ITO (ITO/ZnO-NP), 1,4-bis(3-aminopropyl)piperazine (BAP)-modified ITO, and polyethylenimine ethoxylated (PEIE)-modified ITO, were used for electron-collection electrodes in inverted polymer solar cells (PSCs). The modified ITO electrodes were prepared in air at temperatures below 100 °C, using various ITO films on flexible poly(ethylene terephthalate) substrates (PET-ITO) with sheet resistances ranging from 12 to 60 Ω sq-1. The PET-ITO (12 Ω sq-1)/ZnO-NP PSC exhibited an improved power conversion efficiency (PCE) (2.93%), and this PCE was ˜90% of that observed for a cell using glass-ITO/ZnO-NP (sheet resistance = 10 Ω sq-1 PCE = 3.28%). Additionally, we fabricated a flexible inverted ZnO-NP PSC using an indene-C60 bisadduct (ICBA) as the acceptor material in place of [6,6]-phenyl-C61-butyric acid methyl ester (PCBM) and obtained a PCE of 4.18%.
Changes in effective moisture on the Tibetan Plateau during the period 1981-2010
NASA Astrophysics Data System (ADS)
Yin, Y.; Wu, S.; Zhao, D.
2013-12-01
Observed evaporative demand has decreased worldwide during the past several decades. This trend is also noted on the Tibetan Plateau, a region that is particularly sensitive to climate change. However, actual evapotranspiration trends and their relationship to drought stress on the Tibetan Plateau are poorly understood. We analyzed the spatiotemporal changes in potential evapotranspiration(PET), actual evapotranspiration(AET) and effective moisture (defined as AET/PET) during 1981-2010. Climate data from 80 meteorological stations on the Tibetan Plateau were compiled for the period 1981-2010. New plant functional types were defined for the Tibetan Plateau and evapotranspiration is simulated by the modified Lund-Potsdam-Jena Dynamic Global Vegetation Model (LPJ). The results show regional trends towards decreasing PET and statistically significant increases in AET (p < 0.05) and effective moisture (p < 0.001) during the period 1981-2010. A transition from significant negative to positive PET occurred in 1997. Additionally, a pronounced increase in effective moisture occurred during the period 1981-1997 because of significant decreased PET before 1997.
Very low-dose adult whole-body tumor imaging with F-18 FDG PET/CT
NASA Astrophysics Data System (ADS)
Krol, Andrzej; Naveed, Muhammad; McGrath, Mary; Lisi, Michele; Lavalley, Cathy; Feiglin, David
2015-03-01
The aim of this study was to evaluate if effective radiation dose due to PET component in adult whole-body tumor imaging with time-of-flight F-18 FDG PET/CT could be significantly reduced. We retrospectively analyzed data for 10 patients with the body mass index ranging from 25 to 50. We simulated F-18 FDG dose reduction to 25% of the ACR recommended dose via reconstruction of simulated shorter acquisition time per bed position scans from the acquired list data. F-18 FDG whole-body scans were reconstructed using time-of-flight OSEM algorithm and advanced system modeling. Two groups of images were obtained: group A with a standard dose of F-18 FDG and standard reconstruction parameters and group B with simulated 25% dose and modified reconstruction parameters, respectively. Three nuclear medicine physicians blinded to the simulated activity independently reviewed the images and compared diagnostic quality of images. Based on the input from the physicians, we selected optimal modified reconstruction parameters for group B. In so obtained images, all the lesions observed in the group A were visible in the group B. The tumor SUV values were different in the group A, as compared to group B, respectively. However, no significant differences were reported in the final interpretation of the images from A and B groups. In conclusion, for a small number of patients, we have demonstrated that F-18 FDG dose reduction to 25% of the ACR recommended dose, accompanied by appropriate modification of the reconstruction parameters provided adequate diagnostic quality of PET images acquired on time-of-flight PET/CT.
2017-08-30
Surgically Staged Endometrial and Cervical Carcinoma; Cervical Cancer: Invasive Disease, FIGO Stage 1B1 or Higher; Endometrial Cancer; Stage 1A With Myometrial Invasion or Any Higher Stage and Grade 3; Stage 1A With Myometrial Invasion or Any Other Higher Stage and Serous Papillary or Clear Cell Sub-types; Stage II Disease or Above and Any Histology Grade
[64Cu]XYIMSR-06: A dual-motif CAIX ligand for PET imaging of clear cell renal cell carcinoma.
Minn, Il; Koo, Soo Min; Lee, Hye Soo; Brummet, Mary; Rowe, Steven P; Gorin, Michael A; Sysa-Shah, Polina; Lewis, William D; Ahn, Hye-Hyun; Wang, Yuchuan; Banerjee, Sangeeta Ray; Mease, Ronnie C; Nimmagadda, Sridhar; Allaf, Mohamad E; Pomper, Martin G; Yang, Xing
2016-08-30
Carbonic anhydrase IX (CAIX) is a cell surface enzyme that is over-expressed in approximately 95% of cases of clear cell renal cell carcinoma (ccRCC), the most common renal cancer. We synthesized and performed in vitro and in vivo evaluation of a dual-motif ligand, [64Cu]XYIMSR-06, for imaging CAIX expression on ccRCC tumors using positron emission tomography (PET). [64Cu]XYIMSR-06 was generated in yields of 51.0 ± 4.5% (n=5) and specific activities of 4.1 - 8.9 GBq/μmol (110-240 Ci/mmol). Tumor was visualized on PET images by 1 h post-injection with high tumor-to-background levels (>100 tumor-to-blood and -muscle) achieved within 24 h. Biodistribution studies demonstrated a maximum tumor uptake of 19.3% injected dose per gram of radioactivity at 4 h. Tumor-to-blood, -muscle and -kidney ratios were 129.6 ± 18.8, 84.3 ± 21.0 and 2.1 ± 0.3, respectively, at 8 h post-injection. At 24 h a tumor-to-kidney ratio of 7.1 ± 2.5 was achieved. These results indicate pharmacokinetics superior to those of previously reported imaging agents binding to CAIX. [64Cu]XYIMSR-06 is a new low-molecular-weight PET ligand targeting CAIX, which can image localized and metastatic ccRCC.
The heritage of radiotracers for PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, J.S.; Wolf, A.P.
The history of PET research clearly demonstrates that it is advances in chemistry coupled with a detailed examination of the biochemistry of new radiotracers which has allowed the PET method to be applied to new areas of biology and medicine. Radiotracers whose regional distribution reflects glucose metabolism, neutrotransmitter activity and enzyme activity have all required the development of rapid synthetic methods for the radiotracers themselves and the characterization of their biochemical behavior. This article traces some of the advances in the production of labeled precursors and in radiotracer synthesis and evaluation which have shaped the rapidly expanding application of PETmore » to problems in the neurosciences, in cardiology and in oncology. 54 refs.« less
Graham, Taryn M; Milaney, Katrina J; Adams, Cindy L; Rock, Melanie J
2018-02-27
Previous research has shown that housing insecurity contributes to animal relinquishment and that tenants with dogs face disadvantages in the rental market. Still, little is known about how dog owners navigate rental markets, nor how landlords and property managers perceive dogs and other pets. This case study reports on in-depth interviews with younger tenants with dogs and on open-ended survey responses from landlords and property managers. In their housing searches, tenants with dogs reported feeling powerless in negotiations and feeling discriminated against. They described settling for substandard properties, often located in less desirable neighborhoods. Also, some said they felt obliged to stay put in these rentals, given how difficult it had been to find a place that would accommodate their dogs. Meanwhile, landlords and property managers indicated that listings advertised as "pet-friendly" tend to receive more applicants than listings in which pets are prohibited. Suggestions for improvement included meeting pets prior to signing the lease; getting everything in writing; steering clear from furnished units; charging utilities to tenants; and speeding up the pet approval process when dealing with condominium boards. These suggestions offer implications for future research, partnerships, and policy options to improve the prospects of pets and their people in rental housing.
Kunze, Karl P; Nekolla, Stephan G; Rischpler, Christoph; Zhang, Shelley HuaLei; Hayes, Carmel; Langwieser, Nicolas; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Schwaiger, Markus
2018-04-19
Systematic differences with respect to myocardial perfusion quantification exist between DCE-MRI and PET. Using the potential of integrated PET/MRI, this study was conceived to compare perfusion quantification on the basis of simultaneously acquired 13 NH 3 -ammonia PET and DCE-MRI data in patients at rest and stress. Twenty-nine patients were examined on a 3T PET/MRI scanner. DCE-MRI was implemented in dual-sequence design and additional T 1 mapping for signal normalization. Four different deconvolution methods including a modified version of the Fermi technique were compared against 13 NH 3 -ammonia results. Cohort-average flow comparison yielded higher resting flows for DCE-MRI than for PET and, therefore, significantly lower DCE-MRI perfusion ratios under the common assumption of equal arterial and tissue hematocrit. Absolute flow values were strongly correlated in both slice-average (R 2 = 0.82) and regional (R 2 = 0.7) evaluations. Different DCE-MRI deconvolution methods yielded similar flow result with exception of an unconstrained Fermi method exhibiting outliers at high flows when compared with PET. Thresholds for Ischemia classification may not be directly tradable between PET and MRI flow values. Differences in perfusion ratios between PET and DCE-MRI may be lifted by using stress/rest-specific hematocrit conversion. Proper physiological constraints are advised in model-constrained deconvolution. © 2018 International Society for Magnetic Resonance in Medicine.
Xu, Huan; Zhang, Wei; Li, Yan; Ye, Fei F; Yin, Peng P; Yu, Xiu; Hu, Mei N; Fu, Yuan S; Wang, Che; Shang, De J
2014-11-01
A novel bifunctional liposome with long-circulating and pH-sensitive properties was constructed using poly(2-ethyl-oxazoline)-cholesteryl methyl carbonate (PEtOz-CHMC) in this study. PEtOz-CHMC was synthesized and characterized by TLC, IR and (1)H-NMR. The obtained PEtOz lipid was inserted into liposomes by the post-insertion method. Through a series of experiments, such as drug release, tumor cell uptake, cytotoxicity, calcium-induced aggregation, pharmacokinetic experiments, etc., the pH-sensitive and long-circulating properties of PEtOzylated liposomes was identified. PEtOz-CHMC modified liposomes (PEtOz-L) showed increased calcein release at low pH. Flow cytometric analysis results showed that the fusion and cellular uptake of PEtOz-L could be promoted significantly at pH 6.4 compared with those at pH 7.4. Confocal laser scanning microscope observations revealed that PEtOz-L could respond to low endosomal pH and directly released the fluorescent tracer into the cytoplasm. MTT assays in HeLa cells demonstrated that doxorubicin hydrochloride (DOX) loaded PEtOz-L exhibited stronger anti-tumor activity in a medium at pH 6.4 than in a medium pH 7.4. PEtOz-L remained stable when these liposomes were incubated in calcium chloride solution. The cumulative calcein release rate of PEtOz-L was significantly lower than that of CL when the liposomes were dialysed in PBS. The pharmacokinetic experiments of liposomes in rats showed that t 1/2 and AUC of PEtOz-L were 4.13 times and 4.71 times higher than those of CL. PEtOzylated liposomes exhibits excellent long-circulating and pH-sensitive properties. Our results suggest that PEtOz is a promising biomaterial for the modification of liposome in drug delivery.
Pet Ownership and Cancer Risk in the Women's Health Initiative.
Garcia, David O; Lander, Eric M; Wertheim, Betsy C; Manson, JoAnn E; Volpe, Stella L; Chlebowski, Rowan T; Stefanick, Marcia L; Lessin, Lawrence S; Kuller, Lewis H; Thomson, Cynthia A
2016-09-01
Pet ownership and cancer are both highly prevalent in the United States. Evidence suggests that associations may exist between this potentially modifiable factor and cancer prevention, though studies are sparse. The present report examined whether pet ownership (dog, cat, or bird) is associated with lower risk for total cancer and site-specific obesity-related cancers. This was a prospective analysis of 123,560 participants (20,981 dog owners; 19,288 cat owners; 1,338 bird owners; and 81,953 non-pet owners) enrolled in the Women's Health Initiative observational study and clinical trials. Cox proportional hazards models were used to estimate HR and 95% confidence intervals for the association between pet ownership and cancer, adjusted for potential confounders. There were no significant relationships between ownership of a dog, cat, or bird and incidence of cancer overall. When site-specific cancers were examined, no associations were observed after adjustment for multiple comparisons. Pet ownership had no association with overall cancer incidence. This is the first large epidemiologic study to date to explore relationships between pet ownership and cancer risk, as well as associated risks for individual cancer types. This study requires replication in other sizable, diverse cohorts. Cancer Epidemiol Biomarkers Prev; 25(9); 1311-6. ©2016 AACR. ©2016 American Association for Cancer Research.
Mainenti, Pier Paolo; Iodice, Delfina; Segreto, Sabrina; Storto, Giovanni; Magliulo, Mario; Palma, Giovanni Domenico De; Salvatore, Marco; Pace, Leonardo
2011-01-01
AIM: To evaluate whether FDG-positron emission tomography (PET)/computed tomography (CT) may be an accurate technique in the assessment of the T stage in patients with colorectal cancer. METHODS: Thirty four consecutive patients (20 men and 14 women; mean age: 63 years) with a histologically proven diagnosis of colorectal adenocarcinoma and scheduled for surgery in our hospital were enrolled in this study. All patients underwent FDG-PET/CT preoperatively. The primary tumor site and extent were evaluated on PET/CT images. Colorectal wall invasion was analysed according to a modified T classification that considers only three stages (≤ T2, T3, T4). Assessment of accuracy was carried out using 95% confidence intervals for T. RESULTS: Thirty five/37 (94.6%) adenocarcinomas were identified and correctly located on PET/CT images. PET/CT correctly staged the T of 33/35 lesions identified showing an accuracy of 94.3% (95% CI: 87%-100%). All T1, T3 and T4 lesions were correctly staged, while two T2 neoplasms were overstated as T3. CONCLUSION: Our data suggest that FDG-PET/CT may be an accurate modality for identifying primary tumor and defining its local extent in patients with colorectal cancer. PMID:21472100
Pet Ownership and Cancer Risk in the Women’s Health Initiative
Garcia, David O.; Lander, Eric M.; Wertheim, Betsy C.; Manson, JoAnn E.; Volpe, Stella L.; Chlebowski, Rowan T.; Stefanick, Marcia L.; Lessin, Lawrence S.; Kuller, Lewis H.; Thomson, Cynthia A.
2016-01-01
Background Pet ownership and cancer are both highly prevalent in the U.S. Evidence suggest associations may exist between this potentially modifiable factor and cancer prevention, though studies are sparse. The present report examined whether pet ownership (dog, cat, or bird) is associated with lower risk for total cancer and site-specific obesity-related cancers. Methods A prospective analysis of 123,560 participants (20,981 dog owners; 19,288 cat owners; 1,338 bird owners; and 81,953 non-pet owners) enrolled in the Women’s Health Initiative (WHI) observational study and clinical trials. Cox proportional hazards models were used to estimate hazard ratios (HR) and 95% confidence intervals (CI) for the association between pet ownership and cancer, adjusted for potential confounders. Results There were no significant relationships between ownership of a dog, cat, or bird and incidence of cancer overall. When site-specific cancers were examined, no associations were observed after adjustment for multiple comparisons. Conclusion Pet ownership had no association with overall cancer incidence. Impact This is the first large epidemiological study to date to explore relationships between pet ownership and cancer risk, as well as associated risks for individual cancer types. This study requires replication in other sizable, diverse cohorts. PMID:27365150
Predictors of owner response to companion animal death in 177 clients from 14 practices in Ontario.
Adams, C L; Bonnett, B N; Meek, A H
2000-11-01
To identify predictors of grief and client desires and needs as they relate to pet death. Cross-sectional mail survey. 177 clients, from 14 randomly selected veterinary practices, whose cat or dog died between 6 and 43 days prior to returning the completed questionnaire. Veterinary practices were contacted weekly to obtain the names of clients whose pets had died until approximately 200 clients were identified. Clients were contacted by telephone, and a questionnaire designed to measure grief associated with pet death was mailed to those willing to participate within 1 to 14 days of their pet's death. The questionnaire measured potential correlates and modifiers of grief and included three outcome measures: social/emotional and physical consequences, thought processes, and despair. Demographic data were also collected. Approximately 30% of participants experienced severe grief. The most prominent risk factors for grief included level of attachment, euthanasia, societal attitudes toward pet death, and professional support from the veterinary team. Bivariate and multivariate analyses highlighted the impact owners' attitudes about euthanasia and professional intervention by the veterinary team had on reactions to pet death. Owners' perceptions of societal attitudes, also a predictor of grief, indicate that grief for pets is different than grief associated with other losses.
Three-phase 18F-fluorocholine PET/CT in the evaluation of prostate cancer recurrence.
Steiner, Ch; Vees, H; Zaidi, H; Wissmeyer, M; Berrebi, O; Kossovsky, M P; Khan, H G; Miralbell, R; Ratib, O; Buchegger, F
2009-01-01
Contribution of 3-phase 18F-fluorocholine PET/CT in suspected prostate cancer recurrence at early rise of PSA. Retrospective analysis was performed in 47 patients after initial treatment with radiotherapy (n=30) or surgery (n=17). Following CT, 10 minutes list-mode PET acquisition was done over the prostate bed after injection of 300 MBq of 18F-fluorocholine. Three timeframes of 3 minutes each were reconstructed for analysis. All patients underwent subsequent whole body PET/CT. Delayed pelvic PET/CT was obtained in 36 patients. PET/CT was interpreted visually by two observers and SUVmax determined for suspicious lesions. Biopsies were obtained from 13 patients. Biopsies confirmed the presence of cancer in 11 of 13 patients with positive PET for a total of 15 local recurrences in which average SUVmax increased during 14 minutes post injection and marginally decreased in delayed scanning. Conversely inguinal lymph nodes with mild to moderate metabolic activity on PET showed a clearly different pattern with decreasing SUVmax on dynamic images. Three-phase PET/CT contributed to the diagnostic assessment of 10 of 47 patients with biological evidence of recurrence of cancer. It notably allowed the discrimination of confounding blood pool or urinary activity from suspicious hyperactivities. PET/CT was positive in all patients with PSA>or=2 ng/ml (n=34) and in 4/13 patients presenting PSA values<2 ng/ml. 18F-fluorocholine 3-phase PET/CT showed a progressively increasing SUVmax in biopsy confirmed cancer lesions up to 14 minutes post injection while decreasing in inguinal lymph nodes interpreted as benign. Furthermore, it was very useful in differentiating local recurrences from confounding blood pool and urinary activity.
Massardo, Teresa; Jofré, María Josefina; Sierralta, María Paulina; Canessa, José; Castro, Gabriel; Berrocal, Isabel; Gallegos, Iván
2012-09-01
The usefulness of positron emission tomography (PET) with fluorine-deoxyglucose (FDG) in sarcomas and non-sarcoma non-epithelial (NSNE) tumors is not clearly defined. To report a Chilean experience with NSNE tumors evaluated using PET with FDG. Retrospective review of the database of a PET laboratory. Demographic data, indications and metabolic findings were compared with conventional imaging in 88 adults and children with diverse bone and soft tissue sarcomas as well as 24 gastrointestinal stromal tumors (GIST), 6 pleural malignant mesotheliomas in adults, and 9 medulloblastomas in children. FDG showed good concordance with conventional imaging in NSNE tumors. It was helpful for staging, restaging, follow-up after treatment and for the detection of new not previously suspected lesions. PET with FDG could have a prognostic role and help in patient management, mainly in musculoskeletal and high grade or less differentiated sarcomas. In GIST, it was a good tool for immunotherapy control.
The Value of 18F-FDG PET/CT in Diagnosis and During Follow-up in 273 Patients with Chronic Q Fever.
Kouijzer, Ilse J E; Kampschreur, Linda M; Wever, Peter C; Hoekstra, Corneline; van Kasteren, Marjo E E; de Jager-Leclercq, Monique G L; Nabuurs-Franssen, Marrigje H; Wegdam-Blans, Marjolijn C A; Ammerlaan, Heidi S M; Buijs, Jacqueline; Geus-Oei, Lioe-Fee de; Oyen, Wim J G; Bleeker-Rovers, Chantal P
2018-01-01
In 1%-5% of all acute Q fever infections, chronic Q fever develops, mostly manifesting as endocarditis, infected aneurysms, or infected vascular prostheses. In this study, we investigated the diagnostic value of 18 F-FDG PET/CT in chronic Q fever at diagnosis and during follow-up. Methods: All adult Dutch patients suspected of chronic Q fever who were diagnosed since 2007 were retrospectively included until March 2015, when at least one 18 F-FDG PET/CT scan was obtained. Clinical data and results from 18 F-FDG PET/CT at diagnosis and during follow-up were collected. 18 F-FDG PET/CT scans were prospectively reevaluated by 3 nuclear medicine physicians using a structured scoring system. Results: In total, 273 patients with possible, probable, or proven chronic Q fever were included. Of all 18 F-FDG PET/CT scans performed at diagnosis, 13.5% led to a change in diagnosis. Q fever-related mortality rate in patients with and without vascular infection based on 18 F-FDG PET/CT was 23.8% and 2.1%, respectively ( P = 0.001). When 18 F-FDG PET/CT was added as a major criterion to the modified Duke criteria, 17 patients (1.9-fold increase) had definite endocarditis. At diagnosis, 19.6% of 18 F-FDG PET/CT scans led to treatment modification. During follow-up, 57.3% of 18 F-FDG PET/CT scans resulted in treatment modification. Conclusion: 18 F-FDG PET/CT is a valuable technique in diagnosis of chronic Q fever and during follow-up, often leading to a change in diagnosis or treatment modification and providing important prognostic information on patient survival. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
NASA Astrophysics Data System (ADS)
Mahmud, M. H.; Nordin, A. J.; Saad, F. F. Ahmad; Fattah Azman, A. Z.
2014-11-01
This study aims to estimate the radiation effective dose resulting from whole body fluorine-18 flourodeoxyglucose Positron Emission Tomography (18F-FDG PET) scanning as compared to conservative Computed Tomography (CT) techniques in evaluating oncology patients. We reviewed 19 oncology patients who underwent 18F-FDG PET/CT at our centre for cancer staging. Internal and external doses were estimated using radioactivity of injected FDG and volume CT Dose Index (CTDIvol), respectively with employment of the published and modified dose coefficients. The median differences of dose among the conservative CT and PET protocols were determined using Kruskal Wallis test with p < 0.05 considered as significant. The median (interquartile range, IQR) effective doses of non-contrasted CT, contrasted CT and PET scanning protocols were 7.50 (9.35) mSv, 9.76 (3.67) mSv and 6.30 (1.20) mSv, respectively, resulting in the total dose of 21.46 (8.58) mSv. Statistically significant difference was observed in the median effective dose between the three protocols (p < 0.01). The effective doses of whole body 18F-FDG PET technique may be effective the lowest amongst the conventional CT imaging techniques.
Steinbrecher, A
2010-01-01
Rabies treatises of the 18th and 19th century are being researched in regard to their significance of the keeping of pets, which started to establish itself at the beginning of the 17th century. In doing so it is clearly recognizable that this keeping of pets had become a constant element of the civil urban life. The treatises also show that the physicians declined the keeping of dogs out of pure pleasure.
Cerpa, V; Gonzalez, A; Richerson, G B
2014-10-24
In genetically-modified Lmx1b(f/f/p) mice, selective deletion of LMX1B in Pet-1 expressing cells leads to failure of embryonic development of serotonin (5-HT) neurons. As adults, these mice have a decreased hypercapnic ventilatory response and abnormal thermoregulation. This mouse model has been valuable in defining the normal role of 5-HT neurons, but it is possible that developmental compensation reduces the severity of observed deficits. Here we studied mice genetically modified to express diphtheria toxin receptors (DTR) on Pet-1 expressing neurons (Pet-1-Cre/floxed DTR or Pet1/DTR mice). These mice developed with a normal complement of 5-HT neurons. As adults, systemic treatment with 2-35μg of diphtheria toxin (DT) reduced the number of tryptophan hydroxylase-immunoreactive (TpOH-ir) neurons in the raphe nuclei and ventrolateral medulla by 80%. There were no effects of DT on minute ventilation (VE) or the ventilatory response to hypercapnia or hypoxia. At an ambient temperature (TA) of 24°C, all Pet1/DTR mice dropped their body temperature (TB) below 35°C after DT treatment, but the latency was shorter in males than females (3.0±0.37 vs. 4.57±0.29days, respectively; p<0.001). One week after DT treatment, mice were challenged by dropping TA from 37°C to 24°C, which caused TB to decrease more in males than in females (29.7±0.31°C vs. 33.0±1.3°C, p<0.01). We conclude that the 20% of 5-HT neurons that remain after DT treatment in Pet1/DTR mice are sufficient to maintain normal baseline breathing and a normal response to CO2, while those affected include some essential for thermoregulation, in males more than females. In comparison to models with deficient embryonic development of 5-HT neurons, acute deletion of 5-HT neurons in adults leads to a greater defect in thermoregulation, suggesting that significant developmental compensation can occur. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.
Advancements to the planogram frequency–distance rebinning algorithm
Champley, Kyle M; Raylman, Raymond R; Kinahan, Paul E
2010-01-01
In this paper we consider the task of image reconstruction in positron emission tomography (PET) with the planogram frequency–distance rebinning (PFDR) algorithm. The PFDR algorithm is a rebinning algorithm for PET systems with panel detectors. The algorithm is derived in the planogram coordinate system which is a native data format for PET systems with panel detectors. A rebinning algorithm averages over the redundant four-dimensional set of PET data to produce a three-dimensional set of data. Images can be reconstructed from this rebinned three-dimensional set of data. This process enables one to reconstruct PET images more quickly than reconstructing directly from the four-dimensional PET data. The PFDR algorithm is an approximate rebinning algorithm. We show that implementing the PFDR algorithm followed by the (ramp) filtered backprojection (FBP) algorithm in linogram coordinates from multiple views reconstructs a filtered version of our image. We develop an explicit formula for this filter which can be used to achieve exact reconstruction by means of a modified FBP algorithm applied to the stack of rebinned linograms and can also be used to quantify the errors introduced by the PFDR algorithm. This filter is similar to the filter in the planogram filtered backprojection algorithm derived by Brasse et al. The planogram filtered backprojection and exact reconstruction with the PFDR algorithm require complete projections which can be completed with a reprojection algorithm. The PFDR algorithm is similar to the rebinning algorithm developed by Kao et al. By expressing the PFDR algorithm in detector coordinates, we provide a comparative analysis between the two algorithms. Numerical experiments using both simulated data and measured data from a positron emission mammography/tomography (PEM/PET) system are performed. Images are reconstructed by PFDR+FBP (PFDR followed by 2D FBP reconstruction), PFDRX (PFDR followed by the modified FBP algorithm for exact reconstruction) and planogram filtered backprojection image reconstruction algorithms. We show that the PFDRX algorithm produces images that are nearly as accurate as images reconstructed with the planogram filtered backprojection algorithm and more accurate than images reconstructed with the PFDR+FBP algorithm. Both the PFDR+FBP and PFDRX algorithms provide a dramatic improvement in computation time over the planogram filtered backprojection algorithm. PMID:20436790
Brom, Maarten; Joosten, Lieke; Laverman, Peter; Oyen, Wim J.G.; Béhé, Martin; Gotthardt, Martin; Boerman, Otto C.
2011-01-01
In comparison to somatostatin receptor scintigraphy, gastrin receptor scintigraphy using 111In-DTPA-minigastrin (MG0) showed added value in diagnosing neuroendocrine tumors. We investigated whether the 68Ga-labeled gastrin analogue DOTA-MG0 is suited for positron emission tomography (PET), which could improve image quality. Targeting of cholecystokinin-2 (CCK2)/gastrin receptor–positive tumor cells with DOTA-MG0 labeled with either 111In or 68Ga in vitro was investigated using the AR42J rat tumor cell line. Biodistribution was examined in BALB/c nude mice with a subcutaneous AR42J tumor. In vivo PET imaging was performed using a preclinical PET–computed tomographic scanner. DOTA-MG0 showed high receptor affinity in vitro. Biodistribution studies revealed high tumor uptake of 68Ga-DOTA-MG0: 4.4 ± 1.3 %ID/g at 1 hour postinjection. Coadministration of an excess unlabeled peptide blocked the tumor uptake (0.7 ± 0.1 %ID/g), indicating CCK2/gastrin receptor–mediated uptake (p = .0005). The biodistribution of 68Ga-DOTA-MG0 was similar to that of 111In-DOTA-MG0. Subcutaneous and intraperitoneal tumors were clearly visualized by small-animal PET imaging with 5 MBq 68Ga-DOTA-MG0. 111In- and 68Ga-labeled DOTA-MG0 specifically accumulate in CCK2/gastrin receptor–positive AR42J tumors with similar biodistribution apart from the kidneys. AR42J tumors were clearly visualized by microPET. Therefore, 68Ga-DOTA-MG0 is a promising tracer for PET imaging of CCK2/gastrin receptor–positive tumors in humans. PMID:21439259
SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Y; Bowsher, J; Yan, S
2014-06-01
Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medicalmore » Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.« less
Sensitivity of Rainfall-runoff Model Parametrization and Performance to Potential Evaporation Inputs
NASA Astrophysics Data System (ADS)
Jayathilake, D. I.; Smith, T. J.
2017-12-01
Many watersheds of interest are confronted with insufficient data and poor process understanding. Therefore, understanding the relative importance of input data types and the impact of different qualities on model performance, parameterization, and fidelity is critically important to improving hydrologic models. In this paper, the change in model parameterization and performance are explored with respect to four different potential evapotranspiration (PET) products of varying quality. For each PET product, two widely used, conceptual rainfall-runoff models are calibrated with multiple objective functions to a sample of 20 basins included in the MOPEX data set and analyzed to understand how model behavior varied. Model results are further analyzed by classifying catchments as energy- or water-limited using the Budyko framework. The results demonstrated that model fit was largely unaffected by the quality of the PET inputs. However, model parameterizations were clearly sensitive to PET inputs, as their production parameters adjusted to counterbalance input errors. Despite this, changes in model robustness were not observed for either model across the four PET products, although robustness was affected by model structure.
68Ga-NODAGA-RGDyK PET/CT Imaging in Esophageal Cancer: First-in-Human Imaging.
Van Der Gucht, Axel; Pomoni, Anastasia; Jreige, Mario; Allemann, Pierre; Prior, John O
2016-11-01
Ga-NODAGA-RGDyK(cyclic) and FDG PET/CT were performed in a 39-year-old man for the work-up of a moderately differentiated carcinoma of the gastro-esophageal junction within a clinical study protocol. Although FDG PET images showed intense, diffuse hypermetabolic lesion activity, NODAGA-RGDyK illustrated the neo-angiogenesis process with tracer uptake clearly localized in non-FDG-avid perilesional structures. Neo-angiogenesis is characterized by ανβ3 integrin expression at the lesion surface of newly formed vessels. This case supports evidence that angiogenesis imaging might therefore be a crucial step in early disease identification and localization, metastatization potential, and in monitoring the efficacy of antiangiogenic therapies.
Oturai, Peter S; Mortensen, Jann; Enevoldsen, Henriette; Eigtved, Annika; Backer, Vibeke; Olesen, Knud P; Nielsen, Henrik W; Hansen, Hanne; Stentoft, Poul; Friberg, Lars
2004-08-01
It is not clear whether high-quality coincidence gamma-PET (gPET) cameras can provide clinical data comparable with data obtained with dedicated PET (dPET) cameras in the primary diagnostic work-up of patients with suspected lung cancer. This study focuses on 2 main issues: direct comparison between foci resolved with the 2 different PET scanners and the diagnostic accuracy compared with final diagnosis determined by the combined information from all other investigations and clinical follow-up. Eighty-six patients were recruited to this study through a routine diagnostic program. They all had changes on their chest radiographs, suggesting malignant lung tumor. In addition to the standard diagnostic program, each patient had 2 PET scans that were performed on the same day. After administration of 419 MBq (range = 305-547 MBq) (18)F-FDG, patients were scanned in a dedicated PET scanner about 1 h after FDG administration and in a dual-head coincidence gamma-camera about 3 h after tracer injection. Images from the 2 scans were evaluated in a blinded set-up and compared with the final outcome. Malignant intrathoracic disease was found in 52 patients, and 47 patients had primary lung cancers. dPET detected all patients as having malignancies (sensitivity, 100%; specificity, 50%), whereas gPET missed one patient (sensitivity, 98%; specificity, 56%). For evaluating regional lymph node involvement, sensitivity and specificity rates were 78% and 84% for dPET and 61% and 90% for gPET, respectively. When comparing the 2 PET techniques with clinical tumor stage (TNM), full agreement was obtained in 64% of the patients (Cohen's kappa = 0.56). Comparing categorization of the patients into clinical relevant stages (no malignancy/malignancy suitable for treatment with curative intent/nontreatable malignancy), resulted in full agreement in 81% (Cohen's kappa = 0.71) of patients. Comparing results from a recent generation of gPET cameras obtained about 2 h later than those of dPET, there was a fairly good agreement with regard to detecting primary lung tumors but slightly reduced sensitivity in detecting smaller malignant lesions such as lymph nodes. Depending on the population to be investigated, and if dPET is not available, gPET might provide significant diagnostic information in patients in whom lung cancer is suspected.
Silverman, Daniel H S
2004-04-01
The clinical identification and differential diagnosis of dementias is especially challenging in the early stages, but the need for early, accurate diagnosis has become more important, now that several medications for the treatment of mild to moderate Alzheimer's disease (AD) are available. Many neurodegenerative diseases produce significant brain-function alterations detectable with PET or SPECT even when structural images with CT or MRI reveal no specific abnormalities. (18)F-FDG PET images of AD demonstrate focally decreased cerebral metabolism involving especially the posterior cingulate and neocortical association cortices, while largely sparing the basal ganglia, thalamus, cerebellum, and cortex mediating primary sensory and motor functions. Assessment of the precise diagnostic accuracy of PET had until recently been hindered by the paucity of data on diagnoses made using PET and confirmed by definitive histopathologic examination. In the past few years, however, studies comparing neuropathologic examination with PET have established reliable and consistent accuracy for diagnostic evaluations using PET-accuracies substantially exceeding those of comparable studies of the diagnostic value of SPECT or of both modalities assessed side by side, or of clinical evaluations done without nuclear imaging. Similar data are emerging concerning the prognostic value of (18)F-FDG PET. Improvements in the ability of PET to identify very early changes associated with AD and other neurodegenerative dementias are currently outpacing improvements in therapeutic options, but with advances in potential preventive and disease-modifying treatments appearing imminent, early detection and diagnosis will play an increasing role in the management of dementing illness.
Body-wide anatomy recognition in PET/CT images
NASA Astrophysics Data System (ADS)
Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Zhao, Liming; Torigian, Drew A.
2015-03-01
With the rapid growth of positron emission tomography/computed tomography (PET/CT)-based medical applications, body-wide anatomy recognition on whole-body PET/CT images becomes crucial for quantifying body-wide disease burden. This, however, is a challenging problem and seldom studied due to unclear anatomy reference frame and low spatial resolution of PET images as well as low contrast and spatial resolution of the associated low-dose CT images. We previously developed an automatic anatomy recognition (AAR) system [15] whose applicability was demonstrated on diagnostic computed tomography (CT) and magnetic resonance (MR) images in different body regions on 35 objects. The aim of the present work is to investigate strategies for adapting the previous AAR system to low-dose CT and PET images toward automated body-wide disease quantification. Our adaptation of the previous AAR methodology to PET/CT images in this paper focuses on 16 objects in three body regions - thorax, abdomen, and pelvis - and consists of the following steps: collecting whole-body PET/CT images from existing patient image databases, delineating all objects in these images, modifying the previous hierarchical models built from diagnostic CT images to account for differences in appearance in low-dose CT and PET images, automatically locating objects in these images following object hierarchy, and evaluating performance. Our preliminary evaluations indicate that the performance of the AAR approach on low-dose CT images achieves object localization accuracy within about 2 voxels, which is comparable to the accuracies achieved on diagnostic contrast-enhanced CT images. Object recognition on low-dose CT images from PET/CT examinations without requiring diagnostic contrast-enhanced CT seems feasible.
Kalantari, Faraz; Li, Tianfang; Jin, Mingwu; Wang, Jing
2016-01-01
In conventional 4D positron emission tomography (4D-PET), images from different frames are reconstructed individually and aligned by registration methods. Two issues that arise with this approach are as follows: 1) the reconstruction algorithms do not make full use of projection statistics; and 2) the registration between noisy images can result in poor alignment. In this study, we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) methods for motion estimation/correction in 4D-PET. A modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM-TV) was used to obtain a primary motion-compensated PET (pmc-PET) from all projection data, using Demons derived deformation vector fields (DVFs) as initial motion vectors. A motion model update was performed to obtain an optimal set of DVFs in the pmc-PET and other phases, by matching the forward projection of the deformed pmc-PET with measured projections from other phases. The OSEM-TV image reconstruction was repeated using updated DVFs, and new DVFs were estimated based on updated images. A 4D-XCAT phantom with typical FDG biodistribution was generated to evaluate the performance of the SMEIR algorithm in lung and liver tumors with different contrasts and different diameters (10 to 40 mm). The image quality of the 4D-PET was greatly improved by the SMEIR algorithm. When all projections were used to reconstruct 3D-PET without motion compensation, motion blurring artifacts were present, leading up to 150% tumor size overestimation and significant quantitative errors, including 50% underestimation of tumor contrast and 59% underestimation of tumor uptake. Errors were reduced to less than 10% in most images by using the SMEIR algorithm, showing its potential in motion estimation/correction in 4D-PET. PMID:27385378
NASA Astrophysics Data System (ADS)
Kalantari, Faraz; Li, Tianfang; Jin, Mingwu; Wang, Jing
2016-08-01
In conventional 4D positron emission tomography (4D-PET), images from different frames are reconstructed individually and aligned by registration methods. Two issues that arise with this approach are as follows: (1) the reconstruction algorithms do not make full use of projection statistics; and (2) the registration between noisy images can result in poor alignment. In this study, we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) methods for motion estimation/correction in 4D-PET. A modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM-TV) was used to obtain a primary motion-compensated PET (pmc-PET) from all projection data, using Demons derived deformation vector fields (DVFs) as initial motion vectors. A motion model update was performed to obtain an optimal set of DVFs in the pmc-PET and other phases, by matching the forward projection of the deformed pmc-PET with measured projections from other phases. The OSEM-TV image reconstruction was repeated using updated DVFs, and new DVFs were estimated based on updated images. A 4D-XCAT phantom with typical FDG biodistribution was generated to evaluate the performance of the SMEIR algorithm in lung and liver tumors with different contrasts and different diameters (10-40 mm). The image quality of the 4D-PET was greatly improved by the SMEIR algorithm. When all projections were used to reconstruct 3D-PET without motion compensation, motion blurring artifacts were present, leading up to 150% tumor size overestimation and significant quantitative errors, including 50% underestimation of tumor contrast and 59% underestimation of tumor uptake. Errors were reduced to less than 10% in most images by using the SMEIR algorithm, showing its potential in motion estimation/correction in 4D-PET.
Niedermoser, Sabrina; Chin, Joshua; Wängler, Carmen; Kostikov, Alexey; Bernard-Gauthier, Vadim; Vogler, Nils; Soucy, Jean-Paul; McEwan, Alexander J; Schirrmacher, Ralf; Wängler, Björn
2015-07-01
Radiolabeled peptides for tumor imaging with PET that can be produced with kits are currently in the spotlight of radiopharmacy and nuclear medicine. The diagnosis of neuroendocrine tumors in particular has been a prime example for the usefulness of peptides labeled with a variety of different radionuclides. Among those, (68)Ga and (18)F stand out because of the ease of radionuclide introduction (e.g., (68)Ga isotope) or optimal nuclide properties for PET imaging (slightly favoring the (18)F isotope). The in vivo properties of good manufacturing practice-compliant, newly developed kitlike-producible (18)F-SiFA- and (18)F-SiFAlin- (SiFA = silicon-fluoride acceptor) modified TATE derivatives were compared with the current clinical gold standard (68)Ga-DOTATATE for high-quality imaging of somatostatin receptor-bearing tumors. SiFA- and SiFAlin-derivatized somatostatin analogs were synthesized and radiolabeled using cartridge-based dried (18)F and purified via a C18 cartridge (radiochemical yield 49.8% ± 5.9% within 20-25 min) without high-performance liquid chromatography purification. Tracer lipophilicity and stability in human serum were tested in vitro. Competitive receptor binding affinity studies were performed using AR42J cells. The most promising tracers were evaluated in vivo in an AR42J xenograft mouse model by ex vivo biodistribution and in vivo PET/CT imaging studies for evaluation of their pharmacokinetic profiles, and the results were compared with those of the current clinical gold standard (68)Ga-DOTATATE. Synthetically easily accessible (18)F-labeled silicon-fluoride acceptor-modified somatostatin analogs were developed. They exhibited high binding affinities to somatostatin receptor-positive tumor cells (1.88-14.82 nM). The most potent compound demonstrated comparable pharmacokinetics and an even slightly higher absolute tumor accumulation level in ex vivo biodistribution studies as well as higher tumor standardized uptake values in PET/CT imaging than (68)Ga-DOTATATE in vivo. The radioactivity uptake in nontumor tissue was higher than for (68)Ga-DOTATATE. The introduction of the novel SiFA building block SiFAlin and of hydrophilic auxiliaries enables a favorable in vivo biodistribution profile of the modified TATE peptides, resulting in high tumor-to-background ratios although lower than those observed with (68)Ga-DOTATATE. As further advantage, the SiFA methodology enables a kitlike labeling procedure for (18)F-labeled peptides advantageous for routine clinical application. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Hastings, John; Adams, Elizabeth J
2006-01-01
The International Network of Agencies for Health Technology Assessment (INAHTA) has been tracking activities associated with the clinical use of positron emission tomography (PET) in its members' healthcare systems since 1997 and published its first Joint Project report on PET in 1999. Part 1 of this Joint Project report presents survey results on diffusion, assessment activities, and policy for clinical use related to PET among INAHTA members since 1999. INAHTA members were surveyed in 2003-2004. Twenty-seven INAHTA agencies (69 percent response rate) from nineteen countries responded to the survey. Dedicated PET systems are the most universally installed systems to date. Mobile scanners and modified gamma cameras are used occasionally as lower cost alternatives, and interest in PET-computed tomography hybrid models is rising despite limited assessment of impact on service planning. PET was used and assessed most commonly for managing patients with cancer. All respondents reported having some form of public funding for clinical PET frequently linked to data collection for the purpose of gathering evidence to refine clinical use and guide resource allocation toward indications that maximize clinical and cost-effectiveness. The use of HTA within a continuous quality improvement framework can help optimize scarce resources for evaluation and use of high cost diagnostic technologies such as PET, particularly where potential clinical or cost-effectiveness is considerable but conclusive evidence is lacking.
Stefano, A; Gallivanone, F; Messa, C; Gilardi, M C; Gastiglioni, I
2014-12-01
The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated for each lesion, with and without PVC. The accuracy, reproducibility, clinical feasibility and the metabolic impact on treatment response of the considered PVC method was evaluated. The PVC method was found clinically feasible in bone lesions, with an accuracy of 93% for lesion sphere-equivalent diameter >1 cm. Applying PVC, average SUV values increased, from 7% up to 154% considering both PET-I and PET-II studies, proving the need of the correction. As main finding, PVC modified the therapy response classification in 6 cases according to EORTC 1999 classification and in 5 cases according to PERCIST 1.0 classification. PVC has an important metabolic impact on the assessment of tumor response to treatment by [18F]FDG PET-CT oncological studies.
Zanzani, Sergio Aurelio; Gazzonis, Alessia Libera; Scarpa, Paola; Berrilli, Federica; Manfredi, Maria Teresa
2014-01-01
Intestinal parasites of dogs and cats are cosmopolitan pathogens with zoonotic potential for humans. Our investigation considered their diffusion in dogs and cats from northern Italy areas, specifically the metropolitan area of Milan and two micropolitan areas of neighboring provinces. It included the study of the level of awareness in pet owners of the zoonotic potential from these parasites. A total of 409 fresh fecal samples were collected from household dogs and cats for copromicroscopic analysis and detection of Giardia duodenalis coproantigens. The assemblages of Giardia were also identified. A questionnaire about intestinal parasites biology and zoonotic potential was submitted to 185 pet owners. The overall prevalence of intestinal parasites resulted higher in cats (47.37%-60.42%) and dogs (57.41%-43.02%) from micropolitan areas than that from the metropolis of Milan (dogs: P = 28.16%; cats: P = 32.58 %). The zoonotic parasites infecting pets under investigation were T. canis and T. cati, T. vulpis, Ancylostomatidae, and G. duodenalis assemblage A. Only 49.19% of pet owners showed to be aware of the risks for human health from canine and feline intestinal parasites. Parasitological results in pets and awareness determination in their owners clearly highlight how the role of veterinarians is important in indicating correct and widespread behaviors to reduce risks of infection for pets and humans in urban areas.
NASA Astrophysics Data System (ADS)
Chen, Zao; Liu, Xiaojiang; Wang, Yan; Li, Jun; Guan, Zisheng
2015-12-01
Optical transparency, mechanical flexibility, and fast regeneration are important factors to expand the application of superhydrophobic surfaces. Herein, we fabricated highly transparent, stable, and superhydrophobic coatings through a novel gradient structure design by versatile dip-coating of silica colloid particles (SCPs) and diethoxydimethysiliane cross-linked silica nanoparticles (DDS-SNPs) on polyethylene terephthalate (PET) film and glass, followed by the modification of octadecyltrichlorosiliane (OTCS). When the DDS concentration reached 5 wt%, the modified SCPs/DDS-SNPs coating exhibited a water contact angle (WCA) of 153° and a sliding angle (SA) <5°. Besides, the average transmittance of this superhydrophobic coating on PET film and glass was increased by 2.7% and 1% in the visible wavelength, respectively. This superhydrophobic coating also showed good robustness and stability against water dropping impact, ultrasonic damage, and acid solution. Moreover, the superhydrophobic PET film after physical damage can quickly regain the superhydrophobicity by one-step spray regenerative solution of dodecyltrichlorosilane (DTCS) modified silica nanoparticles at room temperature. The demonstrated method for the preparation and regeneration of superhydrophobic coating is available for different substrates and large-scale production at room temperature.
Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Aarsvold, John N.; Raghunath, Nivedita; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.; Votaw, John R.
2012-01-01
Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [11C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET. PMID:23039679
An investigation on the use of shredded waste PET bottles as aggregate in lightweight concrete.
Akçaözoğlu, Semiha; Atiş, Cengiz Duran; Akçaözoğlu, Kubilay
2010-02-01
In this work, the utilization of shredded waste Poly-ethylene Terephthalate (PET) bottle granules as a lightweight aggregate in mortar was investigated. Investigation was carried out on two groups of mortar samples, one made with only PET aggregates and, second made with PET and sand aggregates together. Additionally, blast-furnace slag was also used as the replacement of cement on mass basis at the replacement ratio of 50% to reduce the amount of cement used and provide savings. The water-binder (w/b) ratio and PET-binder (PET/b) ratio used in the mixtures were 0.45 and 0.50, respectively. The size of shredded PET granules used in the preparation of mortar mixtures were between 0 and 4 mm. The results of the laboratory study and testing carried out showed that mortar containing only PET aggregate, mortar containing PET and sand aggregate, and mortars modified with slag as cement replacement can be drop into structural lightweight concrete category in terms of unit weight and strength properties. Therefore, it was concluded that there is a potential for the use of shredded waste PET granules as aggregate in the production of structural lightweight concrete. The use of shredded waste PET granules due to its low unit weight reduces the unit weight of concrete which results in a reduction in the death weight of a structural concrete member of a building. Reduction in the death weight of a building will help to reduce the seismic risk of the building since the earthquake forces linearly dependent on the dead-weight. Furthermore, it was also concluded that the use of industrial wastes such as PET granules and blast-furnace slag in concrete provides some advantages, i.e., reduction in the use of natural resources, disposal of wastes, prevention of environmental pollution, and energy saving.
An investigation on the use of shredded waste PET bottles as aggregate in lightweight concrete
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akcaoezoglu, Semiha, E-mail: sakcaozoglu@nigde.edu.t; Atis, Cengiz Duran; Akcaoezoglu, Kubilay
2010-02-15
In this work, the utilization of shredded waste Poly-ethylene Terephthalate (PET) bottle granules as a lightweight aggregate in mortar was investigated. Investigation was carried out on two groups of mortar samples, one made with only PET aggregates and, second made with PET and sand aggregates together. Additionally, blast-furnace slag was also used as the replacement of cement on mass basis at the replacement ratio of 50% to reduce the amount of cement used and provide savings. The water-binder (w/b) ratio and PET-binder (PET/b) ratio used in the mixtures were 0.45 and 0.50, respectively. The size of shredded PET granules usedmore » in the preparation of mortar mixtures were between 0 and 4 mm. The results of the laboratory study and testing carried out showed that mortar containing only PET aggregate, mortar containing PET and sand aggregate, and mortars modified with slag as cement replacement can be drop into structural lightweight concrete category in terms of unit weight and strength properties. Therefore, it was concluded that there is a potential for the use of shredded waste PET granules as aggregate in the production of structural lightweight concrete. The use of shredded waste PET granules due to its low unit weight reduces the unit weight of concrete which results in a reduction in the death weight of a structural concrete member of a building. Reduction in the death weight of a building will help to reduce the seismic risk of the building since the earthquake forces linearly dependant on the dead-weight. Furthermore, it was also concluded that the use of industrial wastes such as PET granules and blast-furnace slag in concrete provides some advantages, i.e., reduction in the use of natural resources, disposal of wastes, prevention of environmental pollution, and energy saving.« less
Image Reconstruction for a Partially Collimated Whole Body PET Scanner
Alessio, Adam M.; Schmitz, Ruth E.; MacDonald, Lawrence R.; Wollenweber, Scott D.; Stearns, Charles W.; Ross, Steven G.; Ganin, Alex; Lewellen, Thomas K.; Kinahan, Paul E.
2008-01-01
Partially collimated PET systems have less collimation than conventional 2-D systems and have been shown to offer count rate improvements over 2-D and 3-D systems. Despite this potential, previous efforts have not established image-based improvements with partial collimation and have not customized the reconstruction method for partially collimated data. This work presents an image reconstruction method tailored for partially collimated data. Simulated and measured sensitivity patterns are presented and provide a basis for modification of a fully 3-D reconstruction technique. The proposed method uses a measured normalization correction term to account for the unique sensitivity to true events. This work also proposes a modified scatter correction based on simulated data. Measured image quality data supports the use of the normalization correction term for true events, and suggests that the modified scatter correction is unnecessary. PMID:19096731
Image Reconstruction for a Partially Collimated Whole Body PET Scanner.
Alessio, Adam M; Schmitz, Ruth E; Macdonald, Lawrence R; Wollenweber, Scott D; Stearns, Charles W; Ross, Steven G; Ganin, Alex; Lewellen, Thomas K; Kinahan, Paul E
2008-06-01
Partially collimated PET systems have less collimation than conventional 2-D systems and have been shown to offer count rate improvements over 2-D and 3-D systems. Despite this potential, previous efforts have not established image-based improvements with partial collimation and have not customized the reconstruction method for partially collimated data. This work presents an image reconstruction method tailored for partially collimated data. Simulated and measured sensitivity patterns are presented and provide a basis for modification of a fully 3-D reconstruction technique. The proposed method uses a measured normalization correction term to account for the unique sensitivity to true events. This work also proposes a modified scatter correction based on simulated data. Measured image quality data supports the use of the normalization correction term for true events, and suggests that the modified scatter correction is unnecessary.
FPGA-based RF interference reduction techniques for simultaneous PET-MRI.
Gebhardt, P; Wehner, J; Weissler, B; Botnar, R; Marsden, P K; Schulz, V
2016-05-07
The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) as a multi-modal imaging technique is considered very promising and powerful with regard to in vivo disease progression examination, therapy response monitoring and drug development. However, PET-MRI system design enabling simultaneous operation with unaffected intrinsic performance of both modalities is challenging. As one of the major issues, both the PET detectors and the MRI radio-frequency (RF) subsystem are exposed to electromagnetic (EM) interference, which may lead to PET and MRI signal-to-noise ratio (SNR) deteriorations. Early digitization of electronic PET signals within the MRI bore helps to preserve PET SNR, but occurs at the expense of increased amount of PET electronics inside the MRI and associated RF field emissions. This raises the likelihood of PET-related MRI interference by coupling into the MRI RF coil unwanted spurious signals considered as RF noise, as it degrades MRI SNR and results in MR image artefacts. RF shielding of PET detectors is a commonly used technique to reduce PET-related RF interferences, but can introduce eddy-current-related MRI disturbances and hinder the highest system integration. In this paper, we present RF interference reduction methods which rely on EM field coupling-decoupling principles of RF receive coils rather than suppressing emitted fields. By modifying clock frequencies and changing clock phase relations of digital circuits, the resulting RF field emission is optimised with regard to a lower field coupling into the MRI RF coil, thereby increasing the RF silence of PET detectors. Our methods are demonstrated by performing FPGA-based clock frequency and phase shifting of digital silicon photo-multipliers (dSiPMs) used in the PET modules of our MR-compatible Hyperion II (D) PET insert. We present simulations and magnetic-field map scans visualising the impact of altered clock phase pattern on the spatial RF field distribution, followed by MRI noise and SNR scans performed with an operating PET module using different clock frequencies and phase patterns. The methods were implemented via firmware design changes without any hardware modifications. This introduces new means of flexibility by enabling adaptive RF interference reduction optimisations in the field, e.g. when using a PET insert with different MRI systems or when different MRI RF coil types are to be operated with the same PET detector.
FPGA-based RF interference reduction techniques for simultaneous PET-MRI
NASA Astrophysics Data System (ADS)
Gebhardt, P.; Wehner, J.; Weissler, B.; Botnar, R.; Marsden, P. K.; Schulz, V.
2016-05-01
The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) as a multi-modal imaging technique is considered very promising and powerful with regard to in vivo disease progression examination, therapy response monitoring and drug development. However, PET-MRI system design enabling simultaneous operation with unaffected intrinsic performance of both modalities is challenging. As one of the major issues, both the PET detectors and the MRI radio-frequency (RF) subsystem are exposed to electromagnetic (EM) interference, which may lead to PET and MRI signal-to-noise ratio (SNR) deteriorations. Early digitization of electronic PET signals within the MRI bore helps to preserve PET SNR, but occurs at the expense of increased amount of PET electronics inside the MRI and associated RF field emissions. This raises the likelihood of PET-related MRI interference by coupling into the MRI RF coil unwanted spurious signals considered as RF noise, as it degrades MRI SNR and results in MR image artefacts. RF shielding of PET detectors is a commonly used technique to reduce PET-related RF interferences, but can introduce eddy-current-related MRI disturbances and hinder the highest system integration. In this paper, we present RF interference reduction methods which rely on EM field coupling-decoupling principles of RF receive coils rather than suppressing emitted fields. By modifying clock frequencies and changing clock phase relations of digital circuits, the resulting RF field emission is optimised with regard to a lower field coupling into the MRI RF coil, thereby increasing the RF silence of PET detectors. Our methods are demonstrated by performing FPGA-based clock frequency and phase shifting of digital silicon photo-multipliers (dSiPMs) used in the PET modules of our MR-compatible Hyperion II D PET insert. We present simulations and magnetic-field map scans visualising the impact of altered clock phase pattern on the spatial RF field distribution, followed by MRI noise and SNR scans performed with an operating PET module using different clock frequencies and phase patterns. The methods were implemented via firmware design changes without any hardware modifications. This introduces new means of flexibility by enabling adaptive RF interference reduction optimisations in the field, e.g. when using a PET insert with different MRI systems or when different MRI RF coil types are to be operated with the same PET detector.
NASA Astrophysics Data System (ADS)
Aklan, B.; Jakoby, B. W.; Watson, C. C.; Braun, H.; Ritt, P.; Quick, H. H.
2015-06-01
A simulation toolkit, GATE (Geant4 Application for Tomographic Emission), was used to develop an accurate Monte Carlo (MC) simulation of a fully integrated 3T PET/MR hybrid imaging system (Siemens Biograph mMR). The PET/MR components of the Biograph mMR were simulated in order to allow a detailed study of variations of the system design on the PET performance, which are not easy to access and measure on a real PET/MR system. The 3T static magnetic field of the MR system was taken into account in all Monte Carlo simulations. The validation of the MC model was carried out against actual measurements performed on the PET/MR system by following the NEMA (National Electrical Manufacturers Association) NU 2-2007 standard. The comparison of simulated and experimental performance measurements included spatial resolution, sensitivity, scatter fraction, and count rate capability. The validated system model was then used for two different applications. The first application focused on investigating the effect of an extension of the PET field-of-view on the PET performance of the PET/MR system. The second application deals with simulating a modified system timing resolution and coincidence time window of the PET detector electronics in order to simulate time-of-flight (TOF) PET detection. A dedicated phantom was modeled to investigate the impact of TOF on overall PET image quality. Simulation results showed that the overall divergence between simulated and measured data was found to be less than 10%. Varying the detector geometry showed that the system sensitivity and noise equivalent count rate of the PET/MR system increased progressively with an increasing number of axial detector block rings, as to be expected. TOF-based PET reconstructions of the modeled phantom showed an improvement in signal-to-noise ratio and image contrast to the conventional non-TOF PET reconstructions. In conclusion, the validated MC simulation model of an integrated PET/MR system with an overall accuracy error of less than 10% can now be used for further MC simulation applications such as development of hardware components as well as for testing of new PET/MR software algorithms, such as assessment of point-spread function-based reconstruction algorithms.
NASA Astrophysics Data System (ADS)
Hofmann, Michael; Weitzel, Thilo; Krause, Thomas
2006-12-01
As radio peptide tracers have been developed in recent years for the high sensitive detection of neuroendocrine tumors, still the broad application of other peptides to breast and prostate cancer is missing. A rapid screening of new peptides can, in theory, be based on in vivo screening in animals by PET/CT. To test this hypothesis and to asses the minimum screening time needed per animal, we used the application of Ga-68-DOTATOC PET/CT in rats as test system. The Ga-68-DOTATOC yields in a hot spot imaging with minimal background. To delineate liver and spleen, we performed PET/CT of 10 animals on a SIEMENS Biograph 16 LSO HIGHREZ after intravenous injection of 1.5 MBq Ga-68-DOTATOC per animal. Animals were mounted in an '18 slot' holding device and scanned for a single-bed position. The emission times for the PET scan was varied from 1 to 20 min. The images were assessed first for "PET only" and afterwards in PET/CT fusion mode. The detection of the two organs was good at emission times down to 1 min in PET/CT fusion mode. In the "PET only" scans, the liver was clearly to be identified down to 1 min emission in all animals. But the spleen could only be delineated only by 1 min of emission in the PET/CT-fusion mode. In conclusion the screening of "hot spot" enriching peptides is feasible. "PET only" is in terms of delineation of small organs by far inferior to PET/CT fusion. If animal tumors are above a diameter of 10 mm small, animal PET/CT using clinical high resolution scanners will enable rapid screening. Even the determination of bio-distributions becomes feasible by using list mode tools. The time for the whole survey of 18 animals including anesthesia, preparation and mounting was approximately 20 min. By use of several holding devices mounted simultaneously, a survey time of less than 1 h for 180 animals can be expected.
Yamaguchi, Shotaro; Wagatsuma, Kei; Miwa, Kenta; Ishii, Kenji; Inoue, Kazumasa; Fukushi, Masahiro
2018-03-01
The Bayesian penalized-likelihood reconstruction algorithm (BPL), Q.Clear, uses relative difference penalty as a regularization function to control image noise and the degree of edge-preservation in PET images. The present study aimed to determine the effects of suppression on edge artifacts due to point-spread-function (PSF) correction using a Q.Clear. Spheres of a cylindrical phantom contained a background of 5.3 kBq/mL of [ 18 F]FDG and sphere-to-background ratios (SBR) of 16, 8, 4 and 2. The background also contained water and spheres containing 21.2 kBq/mL of [ 18 F]FDG as non-background. All data were acquired using a Discovery PET/CT 710 and were reconstructed using three-dimensional ordered-subset expectation maximization with time-of-flight (TOF) and PSF correction (3D-OSEM), and Q.Clear with TOF (BPL). We investigated β-values of 200-800 using BPL. The PET images were analyzed using visual assessment and profile curves, edge variability and contrast recovery coefficients were measured. The 38- and 27-mm spheres were surrounded by higher radioactivity concentration when reconstructed with 3D-OSEM as opposed to BPL, which suppressed edge artifacts. Images of 10-mm spheres had sharper overshoot at high SBR and non-background when reconstructed with BPL. Although contrast recovery coefficients of 10-mm spheres in BPL decreased as a function of increasing β, higher penalty parameter decreased the overshoot. BPL is a feasible method for the suppression of edge artifacts of PSF correction, although this depends on SBR and sphere size. Overshoot associated with BPL caused overestimation in small spheres at high SBR. Higher penalty parameter in BPL can suppress overshoot more effectively. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
An approach to the usage of polyethylene terephthalate (PET) waste as roadway pavement material.
Gürü, Metin; Çubuk, M Kürşat; Arslan, Deniz; Farzanian, S Ali; Bilici, İbrahim
2014-08-30
This study investigates an application area for Polyethylene Terephthalate (PET) bottle waste which has become an environmental problem in recent decades as being a considerable part of the total plastic waste bulk. Two novel additive materials, namely Thin Liquid Polyol PET (TLPP) and Viscous Polyol PET (VPP), were chemically derived from waste PET bottles and used to modify the base asphalt separately for this aim. The effects of TLPP and VPP on the asphalt and hot mix asphalt (HMA) mixture properties were detected through conventional tests (Penetration, Softening Point, Ductility, Marshall Stability, Nicholson Stripping) and Superpave methods (Rotational Viscosity, Dynamic Shear Rheometer (DSR), Bending Beam Rheometer (BBR)). Also, chemical structures were described by Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectrometer (EDS) and Fourier Transform Infrared (FTIR) techniques. Since TLPP and VPP were determined to improve the low temperature performance and fatigue resistance of the asphalt as well as the Marshall Stability and stripping resistance of the HMA mixtures based on the results of the applied tests, the usage of PET waste as an asphalt roadway pavement material offers an alternative and a beneficial way of disposal of this ecologically hazardous material. Copyright © 2014 Elsevier B.V. All rights reserved.
Raynor, William; Houshmand, Sina; Gholami, Saeid; Emamzadehfard, Sahra; Rajapakse, Chamith S; Blomberg, Björn Alexander; Werner, Thomas J; Høilund-Carlsen, Poul F; Baker, Joshua F; Alavi, Abass
2016-08-01
(18)F-sodium fluoride (NaF) as an imaging tracer portrays calcium metabolic activity either in the osseous structures or in soft tissue. Currently, clinical use of NaF-PET is confined to detecting metastasis to the bone, but this approach reveals indirect evidence for disease activity and will have limited use in the future in favor of more direct approaches that visualize cancer cells in the read marrow where they reside. This has proven to be the case with FDG-PET imaging in most cancers. However, a variety of studies support the application of NaF-PET to assess benign osseous diseases. In particular, bone turnover can be measured from NaF uptake to diagnose osteoporosis. Several studies have evaluated the efficacy of bisphosphonates and their lasting effects as treatment for osteoporosis using bone turnover measured by NaF-PET. Additionally, NaF uptake in vessels tracks calcification in the plaques at the molecular level, which is relevant to coronary artery disease. Also, NaF-PET imaging of diseased joints is able to project disease progression in osteoarthritis, rheumatoid arthritis, and ankylosing spondylitis. Further studies suggest potential use of NaF-PET in domains such as back pain, osteosarcoma, stress-related fracture, and bisphosphonate-induced osteonecrosis of the jaw. The critical role of NaF-PET in disease detection and characterization of many musculoskeletal disorders has been clearly demonstrated in the literature, and these methods will become more widespread in the future. The data from PET imaging are quantitative in nature, and as such, it adds a major dimension to assessing disease activity.
Positron emission tomography imaging of braintumors with Cobalt-55 and L-[1-C11]-tyrosine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jansen, H.M.L.; Pruim J.; Willemsen, A.T.M.
1994-05-01
The applicability of positron emission tomography (PET) with [C-11] tyrosine (TYR) and Cobalt-55 (Co) in patients with known primary brain tumors is reported. We used Co as a Calcium (Ca) marker to study Ca influx in degenerating neural tissue and TYR to indicate incorporation of amino acids into protein. Four patients showing a primary brain tumor with central necrosis on CT/MRI were studied with Co-PET. Additionally, 2 of these patients were consecutively studied with TYR-PET. Diagnostic confirmation was obtained by means of histology and/or cytology shortly after PET. Thirty-seven MBq Co was administered iv. approximately 24 hours before acquisition. Themore » Co-scan was acquired for I hour. Immediately following Co-PET, 2 patients received 370 MBq TYR iv. TYR-PET acquisition was done dynamically for 55 minutes starting from the time of injection. The necrotic center of the tumor revealed no uptake of either Co or TYR. Vital tumor tissue showed intense uptake of TYR, indicating a high protein synthesis rate (PSR). The circumferent zone between necrotic and tumor tissue showed evident uptake of Co, suggesting cell-decay. In conclusion, TYR and Co are both suitable tracers for visualization of different aspects of brain malignancies, ie. PSR and cell-decay. Combining Co and TYR enables differentiation of necrosis vs. tumor growth with clear marking of the border zone. We think these complementary PET-techniques in conjunction with CT and/or MRI allow the visualization of different aspects of tumor tissue: central necrosis (CT/MRI), cell-decay (Co-PET) and vital tumor tissue (TYR-PET).« less
Näslund, Olivia; Smits, Anja; Förander, Petter; Laesser, Mats; Bartek, Jiri; Gempt, Jens; Liljegren, Ann; Daxberg, Eva-Lotte; Jakola, Asgeir Store
2018-05-24
Positron emission tomography (PET) imaging using amino acid tracers has in recent years become widely used in the diagnosis and prediction of disease course in diffuse low-grade gliomas (LGG). However, implications of preoperative PET for treatment and prognosis in this patient group have not been systematically studied. The aim of this systematic review was to evaluate the preoperative diagnostic and prognostic value of amino acid PET in suspected diffuse LGG. Medline, Cochrane Library, and Embase databases were systematically searched using keywords "PET," "low-grade glioma," and "amino acids tracers" with their respective synonyms. Out of 2137 eligible studies, 28 met the inclusion criteria. Increased amino acid uptake (lesion/brain) was consistently reported among included studies; in 25-92% of subsequently histopathology-verified LGG, in 83-100% of histopathology-verified HGG, and also in some non-neoplastic lesions. No consistent results were found in studies reporting hot spot areas on PET in MRI-suspected LGG. Thus, the diagnostic value of amino acid PET imaging in suspected LGG has proven difficult to interpret, showing clear overlap and inconsistencies among reported results. Similarly, the results regarding the prognostic value of PET in suspected LGG and the correlation between uptake ratios and the molecular tumor status of LGG were conflicting. This systematic review illustrates the difficulties with prognostic studies presenting data on group-level without adjustment for established clinical prognostic factors, leading to a loss of additional prognostic information. We conclude that the prognostic value of PET is limited to analysis of histological subgroups of LGG and is probably strongest when using kinetic analysis of dynamic FET uptake parameters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalantari, F; Wang, J; Li, T
2015-06-15
Purpose: In conventional 4D-PET, images from different frames are reconstructed individually and aligned by registration methods. Two issues with these approaches are: 1) Reconstruction algorithms do not make full use of all projections statistics; and 2) Image registration between noisy images can Result in poor alignment. In this study we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) method for cone beam CT for motion estimation/correction in 4D-PET. Methods: Modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM- TV) is used to obtain a primary motion-compensated PET (pmc-PET) from all projection data using Demons derivedmore » deformation vector fields (DVFs) as initial. Motion model update is done to obtain an optimal set of DVFs between the pmc-PET and other phases by matching the forward projection of the deformed pmc-PET and measured projections of other phases. Using updated DVFs, OSEM- TV image reconstruction is repeated and new DVFs are estimated based on updated images. 4D XCAT phantom with typical FDG biodistribution and a 10mm diameter tumor was used to evaluate the performance of the SMEIR algorithm. Results: Image quality of 4D-PET is greatly improved by the SMEIR algorithm. When all projections are used to reconstruct a 3D-PET, motion blurring artifacts are present, leading to a more than 5 times overestimation of the tumor size and 54% tumor to lung contrast ratio underestimation. This error reduced to 37% and 20% for post reconstruction registration methods and SMEIR respectively. Conclusion: SMEIR method can be used for motion estimation/correction in 4D-PET. The statistics is greatly improved since all projection data are combined together to update the image. The performance of the SMEIR algorithm for 4D-PET is sensitive to smoothness control parameters in the DVF estimation step.« less
Noninvasive imaging of islet grafts using positron-emission tomography
NASA Astrophysics Data System (ADS)
Lu, Yuxin; Dang, Hoa; Middleton, Blake; Zhang, Zesong; Washburn, Lorraine; Stout, David B.; Campbell-Thompson, Martha; Atkinson, Mark A.; Phelps, Michael; Gambhir, Sanjiv Sam; Tian, Jide; Kaufman, Daniel L.
2006-07-01
Islet transplantation offers a potential therapy to restore glucose homeostasis in type 1 diabetes patients. However, islet transplantation is not routinely successful because most islet recipients gradually lose graft function. Furthermore, serological markers of islet function are insensitive to islet loss until the latter stages of islet graft rejection. A noninvasive method of monitoring islet grafts would aid in the assessment of islet graft survival and the evaluation of interventions designed to prolong graft survival. Here, we show that recombinant adenovirus can engineer isolated islets to express a positron-emission tomography (PET) reporter gene and that these islets can be repeatedly imaged by using microPET after transplantation into mice. The magnitude of signal from engineered islets implanted into the axillary cavity was directly related to the implanted islet mass. PET signals attenuated over the following weeks because of the transient nature of adenovirus-mediated gene expression. Because the liver is the preferred site for islet implantation in humans, we also tested whether islets could be imaged after transfusion into the mouse liver. Control studies revealed that both intrahepatic islet transplantation and hyperglycemia altered the biodistribution kinetics of the PET probe systemically. Although transplanted islets were dispersed throughout the liver, clear signals from the liver region of mice receiving PET reporter-expressing islets were detectable for several weeks. Viral transduction, PET reporter expression, and repeated microPET imaging had no apparent deleterious effects on islet function after implantation. These studies lay a foundation for noninvasive quantitative assessments of islet graft survival using PET. diabetes | transplantation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higgins, K; Wu, Q; Perez, B
2014-06-15
Purpose: Local failure occurs in a large proportion of esophageal cancer patients treated with chemoradiation. The treatment strategy for non-responders could potentially be modified if they are identified during therapy. This work investigates the utility of an interim 18FDG-PET scan acquired during the course of therapy as a predictor of pathological response post-therapy. Methods: Fifteen patients underwent 18FDG-PET scanning prior to radiation therapy (RT) and once during RT, after delivery of ∼32 Gy. The physician-contoured GTV on the planning CT scan was used to automatically segment a PET-based GTV on the pre-RT PET (GTV-pre-PET) as the volume with >40% ofmore » the maximum GTV PET SUV value. The pre- and intra-RT CTs were deformably registered to each other to transfer the GTV-pre-PET to the intra-RT PET (GTV-intra-PET). The fractional decrease in the maximum SUV, mean SUV and the SUV to the highest intensity 10% – 90% volumes from GTV-pre-PET to GTV-intra-PET were compared to pathological response assessed at the time of post-RT surgery. Results: Based on post-treatment pathology of 15 patients, 7 were classified as achieving favorable response (treatment effect grade ≤ 1) and 8 as unfavorable response (treatment effect grade > 1). Neither fractional decrease in maximum SUV nor mean SUV were significant between the favorable and unfavorable groups. However, the fractional decrease in SUV20% (SUV to the highest 20% volume) was significant (p = 0.02), with an area under the Receiver Operating Characteristics (ROC) curve of 0.84. An optimal cutoff value of 0.46 for this metric was able to distinguish between the two groups with 71% sensitivity (favorable) and 88% specificity (unfavorable). Conclusion: The fractional decrease in SUV to the volume with highest 20% intensity from pre- to intra-RT 18FDG-PET imaging may be used to distinguish between favorable and unfavorable responders with high sensitivity and specificity.« less
National surveillance for human and pet contact with oral rabies vaccine baits, 2001-2009.
Roess, Amira A; Rea, Nancy; Lederman, Edith; Dato, Virginia; Chipman, Richard; Slate, Dennis; Reynolds, Mary G; Damon, Inger K; Rupprecht, Charles E
2012-01-15
To determine the rate and absolute number of human and pet exposures to oral rabies vaccine (ORV) bait containing liquid vaccinia rabies glycoprotein recombinant vaccine and to evaluate factors that might affect human contact with bait to modify the program and reduce human exposure to the vaccine. Retrospective analysis of surveillance data (2001 to 2009). Reports on human and pet contact with ORV baits in states with ORV surveillance programs. Data were collected from passive, multistate ORV surveillance systems in Alabama, Arizona, Florida, Georgia, Maine, Maryland, Massachusetts, New Hampshire, New Jersey, New York, North Carolina, Ohio, Pennsylvania, Tennessee, Texas, Vermont, Virginia, and West Virginia. Data collected included the nature of human or pet contact with bait and vaccine, the caller's knowledge of the ORV bait program, local human population density, and other relevant demographic data. All 18 states participated in the surveillance program for at least 1 year, for a combined 68 years of observation. One thousand four hundred thirty-six calls were reported, representing 3,076 found baits (6.89/100,000 baits dropped); 296 (20%) calls were related to human contact with ruptured bait, and 550 (38%) involved pet contact with the bait. Six adverse events in humans were reported, one of which required hospitalization. Fifty-nine adverse events in pets were noted, all of which were nonserious. Findings from surveillance activities have been used to improve baiting strategies and minimize human and pet contact with ORV baits. Overall, human and pet contact with ORV baits was infrequent. Surveillance has led to early identification of persons exposed to ORV and rapid intervention.
NASA Astrophysics Data System (ADS)
Xue, Baoxia; Niu, Mei; Yang, Yongzhen; Bai, Jie; Song, Yinghao; Peng, Yun; Liu, Xuguang
2017-08-01
In this account, magnesium hydroxide (MH) employed as a capsule wall was firstly coated on the surface of carbon microspheres (CMSs) to obtain MH@CMSs using liquid phase deposition, then was modified by 3-Aminopropyltriethoxysilane (APTS) to form FMH@CMSs. To investigate the interface binding forces, a series of PET composites was prepared by melt compounding with MH@CMSs or FMH@CMSs. Field-emission scanning electron microscopy (FESEM), Transmission electron microscopy (TEM), Fourier-transform Infrared spectrometry (FTIR) and X-ray photoelectron spectroscopy (XPS) were used to characterize the morphology, chemical structure, and effect of functionalization of CMSs. The coating degree and thermal stability were investigated by thermogravimetry analysis. The results showed that CMSs were coated by an inorganic shell layer of MH as a capsule wall. On the other hand, MH@CMSs were coated with an organic layer of APTS. When compared to MH@CMSs, the interface binding forces between FMH@CMSs and PET matrix were significantly improved, and the tensile strength of FMH@CMSs/PET was higher than that of MH@CMSs/PET. At 1 wt% mass fraction of FMH@CMSs, the limiting oxygen index (LOI) value of PET composites increased from 21% to 27.6% following a V-0 rating. The tensile strength of FMH@CMSs/PET increased by 66.2% to reach 47.20 MPa, a value nearly similar to that of PET. Overall, the formed two layers provided the FMH@CMSs/PET with good mechanical and flame-retardant properties, which would broaden their scope of application.
Janelidze, Shorena; Pannee, Josef; Mikulskis, Alvydas; Chiao, Ping; Zetterberg, Henrik; Blennow, Kaj; Hansson, Oskar
2017-12-01
Visual assessment of amyloid positron emission tomographic (PET) images has been approved by regulatory authorities for clinical use. Several immunoassays have been developed to measure β-amyloid (Aβ) 42 in cerebrospinal fluid (CSF). The agreement between CSF Aβ42 measures from different immunoassays and visual PET readings may influence the use of CSF biomarkers and/or amyloid PET assessment in clinical practice and trials. To determine the concordance between CSF Aβ42 levels measured using 5 different immunoassays and visual amyloid PET analysis. The study included 262 patients with mild cognitive impairment or subjective cognitive decline from the Swedish BioFINDER (Biomarkers for Identifying Neurodegenerative Disorders Early and Reliably) cohort (recruited from September 1, 2010, through December 31, 2014) who had undergone flutemetamol F 18 ([18F]flutemetamol)-labeled PET. Levels of CSF Aβ42 were analyzed using the classic INNOTEST and the newer modified INNOTEST, fully automated Lumipulse (FL), EUROIMMUN (EI), and Meso Scale Discovery (MSD) assays. Concentrations of CSF Aβ were assessed using an antibody-independent mass spectrometry-based reference measurement procedure. The concordance of CSF Aβ42 levels and Aβ42:Aβ40 and Aβ42:tau ratios with visual [18F]flutemetamol PET status. Of 262 participants (mean [SD] age, 70.9 [5.5] years), 108 were women (41.2%) and 154 were men (58.8%). The mass spectrometry-derived Aβ42 values showed higher correlations with the modified Aβ42-INNOTEST (r = 0.97), Aβ42-FL (r = 0.93), Aβ42-EI (r = 0.93), and Aβ42-MSD (r = 0.95) assays compared with the classic Aβ42-INNOTEST assay (r = 0.88; P ≤ .01). The signal in the classic Aβ42-INNOTEST assay was partly quenched by recombinant Aβ1-40 peptide. However, the classic Aβ42-INNOTEST assay showed better concordance with visual [18F]flutemetamol PET status (area under the receiver operating characteristic curve [AUC], 0.92) compared with the newer assays (AUCs, 0.87-0.89; P ≤ .01). The accuracies of the newer assays improved significantly when Aβ42:Aβ40 (AUCs, 0.93-0.95; P ≤ .01), Aβ42 to total tau (T-tau) (AUCs, 0.94; P ≤ .05), or Aβ42 to phosphorylated tau (P-tau) (AUCs, 0.94-0.95; P ≤ .001) ratios were used. A combination of the Aβ42:Aβ40 ratio and T-tau or P-tau level did not improve the accuracy compared with the ratio alone. Concentrations of CSF Aβ42 derived from the new immunoassays (modified INNOTEST, FL, EI, and MSD) may correlate better with the antibody-independent mass spectrometry-based reference measurement procedure and may show improved agreement with visual [18F]flutemetamol PET assessment when using the Aβ42:Aβ40 or Aβ42:tau ratios. These findings suggest the benefit of implementing the CSF Aβ42:Aβ40 or Aβ42:tau ratios as a biomarker of amyloid deposition in clinical practice and trials.
Tumor Lysing Genetically Engineered T Cells Loaded with Multi-Modal Imaging Agents
NASA Astrophysics Data System (ADS)
Bhatnagar, Parijat; Alauddin, Mian; Bankson, James A.; Kirui, Dickson; Seifi, Payam; Huls, Helen; Lee, Dean A.; Babakhani, Aydin; Ferrari, Mauro; Li, King C.; Cooper, Laurence J. N.
2014-03-01
Genetically-modified T cells expressing chimeric antigen receptors (CAR) exert anti-tumor effect by identifying tumor-associated antigen (TAA), independent of major histocompatibility complex. For maximal efficacy and safety of adoptively transferred cells, imaging their biodistribution is critical. This will determine if cells home to the tumor and assist in moderating cell dose. Here, T cells are modified to express CAR. An efficient, non-toxic process with potential for cGMP compliance is developed for loading high cell number with multi-modal (PET-MRI) contrast agents (Super Paramagnetic Iron Oxide Nanoparticles - Copper-64; SPION-64Cu). This can now be potentially used for 64Cu-based whole-body PET to detect T cell accumulation region with high-sensitivity, followed by SPION-based MRI of these regions for high-resolution anatomically correlated images of T cells. CD19-specific-CAR+SPIONpos T cells effectively target in vitro CD19+ lymphoma.
Bartholomä, Mark D; He, Huamei; Pacak, Christina A; Dunning, Patricia; Fahey, Frederic H; McGowan, Francis X; Cowan, Douglas B; Treves, S Ted; Packard, Alan B
2013-11-01
Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an (18)F-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on (18)F-labeled rhodamine B. The goal of this study was to more completely define the biological properties of (18)F-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake (18)F-labeled rhodamine B by cardiomyocytes. A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100-150 μCi of (18)F-labeled rhodamine B diethylene glycol ester ([(18)F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [(18)F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Small-animal PET showed intense and uniform uptake of [(18)F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [(18)F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ~40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [(18)F]RhoBDEGF in the mitochondria of rat cardiomyocytes. Fluorine-18-labeled rhodamine B diethylene glycol ester ([(18)F]RhoBDEGF) provides excellent image quality and clear delineation of myocardial infarcts in a rat infarct model. In vitro studies demonstrate localization of the tracer in the mitochondria of cardiac myocytes. In combination, these results support the continued evaluation of this tracer for the PET assessment of myocardial perfusion. © 2013.
Bartholomä, Mark D.; He, Huamei; Pacak, Christina; Dunning, Patricia; Fahey, Frederic H.; McGowan, Francis; Cowan, Douglas; Treves, S. Ted; Packard, Alan B.
2013-01-01
Introduction Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an F-18-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on F-18-labeled rhodamine B. The goal of this study was to more completely define the biological properties of F-18-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake F-18-labeled rhodamine B by cardiomyocytes. Methods A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100–150 µCi of F-18-labeled rhodamine B diethylene glycol ester ([18F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1 mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [18F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Results Small-animal PET showed intense and uniform uptake of [18F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [18F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ~40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [18F]RhoBDEGF in the mitochondria of rat cardiomyocytes. Conclusion Fluorine-18-labeled rhodamine B diethylene glycol ester ([18F]RhoBDEGF) provides excellent image quality and clear delineation of myocardial infarcts in a rat infarct model. In vitro studies demonstrate localization of the tracer in the mitochondria of cardiac myocytes. In combination, these results support the continued evaluation of this tracer for the PET assessment of myocardial perfusion. PMID:24011396
Łukaszewicz-Moszyńska, Zuzanna; Lachowska, Magdalena; Niemczyk, Kazimierz
2014-01-01
The purpose of this study was to evaluate possible relationships between duration of cochlear implant use and results of positron emission tomography (PET) measurements in the temporal lobes performed while subjects listened to speech stimuli. Other aspects investigated were whether implantation side impacts significantly on cortical representations of functions related to understanding speech (ipsi- or contralateral to the implanted side) and whether any correlation exists between cortical activation and speech therapy results. Objective cortical responses to acoustic stimulation were measured, using PET, in nine cochlear implant patients (age range: 15 to 50 years). All the patients suffered from bilateral deafness, were right-handed, and had no additional neurological deficits. They underwent PET imaging three times: immediately after the first fitting of the speech processor (activation of the cochlear implant), and one and two years later. A tendency towards increasing levels of activation in areas of the primary and secondary auditory cortex on the left side of the brain was observed. There was no clear effect of the side of implantation (left or right) on the degree of cortical activation in the temporal lobe. However, the PET results showed a correlation between degree of cortical activation and speech therapy results.
Łukaszewicz-Moszyńska, Zuzanna; Lachowska, Magdalena; Niemczyk, Kazimierz
2014-01-01
Summary The purpose of this study was to evaluate possible relationships between duration of cochlear implant use and results of positron emission tomography (PET) measurements in the temporal lobes performed while subjects listened to speech stimuli. Other aspects investigated were whether implantation side impacts significantly on cortical representations of functions related to understanding speech (ipsi- or contralateral to the implanted side) and whether any correlation exists between cortical activation and speech therapy results. Objective cortical responses to acoustic stimulation were measured, using PET, in nine cochlear implant patients (age range: 15 to 50 years). All the patients suffered from bilateral deafness, were right-handed, and had no additional neurological deficits. They underwent PET imaging three times: immediately after the first fitting of the speech processor (activation of the cochlear implant), and one and two years later. A tendency towards increasing levels of activation in areas of the primary and secondary auditory cortex on the left side of the brain was observed. There was no clear effect of the side of implantation (left or right) on the degree of cortical activation in the temporal lobe. However, the PET results showed a correlation between degree of cortical activation and speech therapy results. PMID:25306122
Development of a small prototype for a proof-of-concept of OpenPET imaging
NASA Astrophysics Data System (ADS)
Yamaya, Taiga; Yoshida, Eiji; Inaniwa, Taku; Sato, Shinji; Nakajima, Yasunori; Wakizaka, Hidekatsu; Kokuryo, Daisuke; Tsuji, Atsushi; Mitsuhashi, Takayuki; Kawai, Hideyuki; Tashima, Hideaki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Haneishi, Hideaki; Suga, Mikio; Kinouchi, Shoko
2011-02-01
The OpenPET geometry is our new idea to visualize a physically opened space between two detector rings. In this paper, we developed the first small prototype to show a proof-of-concept of OpenPET imaging. Two detector rings of 110 mm diameter and 42 mm axial length were placed with a gap of 42 mm. The basic imaging performance was confirmed through phantom studies; the open imaging was realized at the cost of slight loss of axial resolution and 24% loss of sensitivity. For a proof-of-concept of PET image-guided radiation therapy, we carried out the in-beam tests with 11C radioactive beam irradiation in the heavy ion medical accelerator in Chiba to visualize in situ distribution of primary particles stopped in a phantom. We showed that PET images corresponding to dose distribution were obtained. For an initial proof-of-concept of real-time multimodal imaging, we measured a tumor-inoculated mouse with 18F-FDG, and an optical image of the mouse body surface was taken during the PET measurement by inserting a digital camera in the ring gap. We confirmed that the tumor in the gap was clearly visualized. The result also showed the extension effect of an axial field-of-view (FOV); a large axial FOV of 126 mm was obtained with the detectors that originally covered only an 84 mm axial FOV. In conclusion, our initial imaging studies showed promising performance of the OpenPET.
NASA Astrophysics Data System (ADS)
Hussein, Amal A.; Alzuhairi, Mohammed; Aljanabi, Noor H.
2018-05-01
Accumulation of plastics, especially Polyethylene terephthalate (PET), is an ever increasing ecological threat due to its excessive usage in everyday human life. Nowadays, there are many methods to get rid of plastic wastes including burning, recycling and burying. However, these methods are not very active since their long period, anaerobic conditions that increase the rate of toxic materials released into the environment. This work aims to study the biological degradation of PET microorganism isolated from soil sample. Thirty eight (38) bacterial isolates were isolated from ten soil and plastic waste sample collected from four different waste disposal sites in Baghdad city during different periods between December 2016 and March 2017. Isolation was performed using enrichment culture method (flasks method) by culturing the soil samples in flasks with MSM medium where there is no carbon source only PET. Results showed that Al-Za'farania sample gave a higher number of isolates (13 isolates), while other samples gave less number of isolates. Screening was performed depending on their ability to grow in liquid MSM which contains PET powder and pieces and change the color of the PET-emulsified liquid medium as well as their ability to form the clear zone on PET-MSM agar. The results showed that NH-D-1 isolate has the higher ability to degrade DPET and PET pieces. According to morphological, biochemical characterization and Vitek-2 technique, the most active isolate was identified as Acinetobacter baumannii.
FPGA-based RF interference reduction techniques for simultaneous PET–MRI
Gebhardt, P; Wehner, J; Weissler, B; Botnar, R; Marsden, P K; Schulz, V
2016-01-01
Abstract The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) as a multi-modal imaging technique is considered very promising and powerful with regard to in vivo disease progression examination, therapy response monitoring and drug development. However, PET–MRI system design enabling simultaneous operation with unaffected intrinsic performance of both modalities is challenging. As one of the major issues, both the PET detectors and the MRI radio-frequency (RF) subsystem are exposed to electromagnetic (EM) interference, which may lead to PET and MRI signal-to-noise ratio (SNR) deteriorations. Early digitization of electronic PET signals within the MRI bore helps to preserve PET SNR, but occurs at the expense of increased amount of PET electronics inside the MRI and associated RF field emissions. This raises the likelihood of PET-related MRI interference by coupling into the MRI RF coil unwanted spurious signals considered as RF noise, as it degrades MRI SNR and results in MR image artefacts. RF shielding of PET detectors is a commonly used technique to reduce PET-related RF interferences, but can introduce eddy-current-related MRI disturbances and hinder the highest system integration. In this paper, we present RF interference reduction methods which rely on EM field coupling–decoupling principles of RF receive coils rather than suppressing emitted fields. By modifying clock frequencies and changing clock phase relations of digital circuits, the resulting RF field emission is optimised with regard to a lower field coupling into the MRI RF coil, thereby increasing the RF silence of PET detectors. Our methods are demonstrated by performing FPGA-based clock frequency and phase shifting of digital silicon photo-multipliers (dSiPMs) used in the PET modules of our MR-compatible Hyperion IID PET insert. We present simulations and magnetic-field map scans visualising the impact of altered clock phase pattern on the spatial RF field distribution, followed by MRI noise and SNR scans performed with an operating PET module using different clock frequencies and phase patterns. The methods were implemented via firmware design changes without any hardware modifications. This introduces new means of flexibility by enabling adaptive RF interference reduction optimisations in the field, e.g. when using a PET insert with different MRI systems or when different MRI RF coil types are to be operated with the same PET detector. PMID:27049898
Silicon oxide permeation barrier coating of PET bottles and foils
NASA Astrophysics Data System (ADS)
Steves, Simon; Deilmann, Michael; Awakowicz, Peter
2009-10-01
Modern packaging materials such as polyethylene terephthalate (PET) have displaced established materials in many areas of food and beverage packaging. Plastic packing materials offer are various advantages concerning production and handling. PET bottles for instance are non-breakable and lightweight compared to glass and metal containers. However, PET offers poor barrier properties against gas permeation. Therefore, the shelf live of packaged food is reduced. Permeation of gases can be reduced by depositing transparent plasma polymerized silicon oxide (SiOx) barrier coatings. A microwave (2.45 GHz) driven low pressure plasma reactor is developed based on a modified Plasmaline antenna to treat PET foils or bottles. To increase the barrier properties of the coatings furthermore a RF substrate bias (13.56 MHz) is applied. The composition of the coatings is analyzed by means of Fourier transform infrared (FTIR) spectroscopy regarding carbon and hydrogen content. Influence of gas phase composition and substrate bias on chemical composition of the coatings is discussed. A strong relation between barrier properties and film composition is found: good oxygen barriers are observed as carbon content is reduced and films become quartz-like. Regarding oxygen permeation a barrier improvement factor (BIF) of 70 is achieved.
Development of a Widely Usable Amino Acid Tracer: ⁷⁶Br-α-Methyl-Phenylalanine for Tumor PET Imaging.
Hanaoka, Hirofumi; Ohshima, Yasuhiro; Suzuki, Yurika; Yamaguchi, Aiko; Watanabe, Shigeki; Uehara, Tomoya; Nagamori, Shushi; Kanai, Yoshikatsu; Ishioka, Noriko S; Tsushima, Yoshito; Endo, Keigo; Arano, Yasushi
2015-05-01
Radiolabeled amino acids are superior PET tracers for the imaging of malignant tumors, and amino acids labeled with (76)Br, an attractive positron emitter because of its relatively long half-life (16.2 h), could potentially be a widely usable tumor imaging tracer. In this study, in consideration of its stability and tumor specificity, we designed two (76)Br-labeled amino acid derivatives, 2-(76)Br-bromo-α-methyl-l-phenylalanine (2-(76)Br-BAMP) and 4-(76)Br-bromo-α-methyl-l-phenylalanine (4-(76)Br-BAMP), and investigated their potential as tumor imaging agents. Both (76)Br- and (77)Br-labeled amino acid derivatives were prepared. We performed in vitro and in vivo stability studies and cellular uptake studies using the LS180 colon adenocarcinoma cell line. Biodistribution studies in normal mice and in LS180 tumor-bearing mice were performed, and the tumors were imaged with a small-animal PET scanner. Both (77)Br-BAMPs were stable in the plasma and in the murine body. Although both (77)Br-BAMPs were taken up by LS180 cells and the uptake was inhibited by L-type amino acid transporter 1 inhibitors, 2-(77)Br-BAMP exhibited higher uptake than 4-(77)Br-BAMP. In the biodistribution studies, 2-(77)Br-BAMP showed more rapid blood clearance and lower renal accumulation than 4-(77)Br-BAMP. More than 90% of the injected radioactivity was excreted in the urine by 6 h after the injection of 2-(77)Br-BAMP. High tumor accumulation of 2-(77)Br-BAMP was observed in tumor-bearing mice, and PET imaging with 2-(76)Br-BAMP enabled clear visualization of the tumors. 2-(77)Br-BAMP exhibited preferred pharmacokinetics and high LS180 tumor accumulation, and 2-(76)Br-BAMP enabled clear visualization of the tumors by PET imaging. These findings suggest that 2-(76)Br-BAMP could constitute a potential new PET tracer for tumor imaging and may eventually enable the wider use of amino acid tracers. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Retail lighting and packaging influence consumer acceptance of fluid milk.
Potts, H L; Amin, K N; Duncan, S E
2017-01-01
Little is known about the effect of retail light-emitting diode (LED) exposure on consumer acceptance of milk. The study objective was to determine effects of fluorescent and LED lighting under retail storage conditions on consumer acceptance of milk. Consumer acceptance of milk stored under retail conditions was determined through sensory evaluation (2 studies; n=150+ each) and analytical measures (dissolved oxygen, secondary oxidation products, riboflavin retention). Study 1 evaluated milk stored in high-density polyethylene (HDPE) packages for 4h under LED light (960 lx). Commercially available HDPE package treatments included translucent HDPE (most commonly used), white HDPE [low concentration (1.3%) TiO 2 ], and yellow HDPE; in addition, HDPE with a higher TiO 2 concentration (high white; 4.9% TiO 2 ) and a foil-wrapped translucent HDPE (control) were tested. Translucent and control packages also were tested under fluorescent light. Study 2 evaluated polyethylene terephthalate (PET) packages for 4h under fluorescent and LED light (1,460 lx). The PET packaging included 2 treatments (medium, 4.0% TiO 2 ; high, 6.6% TiO 2 ) as well as translucent HDPE (exposed to fluorescent), clear PET (fluorescent and LED), and light-protected control. Overall mean acceptability of milk ranged from "like slightly" to "like moderately" with significantly lower acceptability for milk exposed to fluorescent light. Milk in HDPE and PET packages had comparable overall acceptability scores when exposed to LED light. Only the fluorescent light condition (both PET and HDPE) diminished overall acceptability. Fluorescent light exposure negatively influenced flavor with significant penalty (2.0-2.5 integers) to overall acceptability of milk in translucent HDPE and clear PET. The LED also diminished aftertaste of milk packaged in translucent HDPE. Changes in dissolved oxygen content, as an indication of oxidation, supported the observed differences in consumer acceptance of milk stored under fluorescent and LED light. Consumers like the flavor of fresh milk, which can be protected by selecting appropriate packaging that blocks detrimental light wavelengths. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, L.; Lai, C.; Marchewka, R.; Berry, R. M.; Tam, K. C.
2016-07-01
Structural colors and photoluminescence have been widely used for anti-counterfeiting and security applications. We report for the first time the use of CdS quantum dot (QD)-functionalized cellulose nanocrystals (CNCs) as building blocks to fabricate nanothin films via layer-by-layer (LBL) self-assembly for anti-counterfeiting applications. Both negatively- and positively-charged CNC/QD nanohybrids with a high colloidal stability and a narrow particle size distribution were prepared. The controllable LBL coating process was characterized by scanning electron microscopy and ellipsometry. The rigid structure of CNCs leads to nanoporous structured films on poly(ethylene terephthalate) (PET) substrates with high transmittance (above 70%) over the entire range of visible light and also resulted in increased hydrophilicity (contact angles of ~40 degrees). Nanothin films on PET substrates showed good flexibility and enhanced stability in both water and ethanol. The modified PET films with structural colors from thin-film interference and photoluminescence from QDs can be used in anti-counterfeiting applications.Structural colors and photoluminescence have been widely used for anti-counterfeiting and security applications. We report for the first time the use of CdS quantum dot (QD)-functionalized cellulose nanocrystals (CNCs) as building blocks to fabricate nanothin films via layer-by-layer (LBL) self-assembly for anti-counterfeiting applications. Both negatively- and positively-charged CNC/QD nanohybrids with a high colloidal stability and a narrow particle size distribution were prepared. The controllable LBL coating process was characterized by scanning electron microscopy and ellipsometry. The rigid structure of CNCs leads to nanoporous structured films on poly(ethylene terephthalate) (PET) substrates with high transmittance (above 70%) over the entire range of visible light and also resulted in increased hydrophilicity (contact angles of ~40 degrees). Nanothin films on PET substrates showed good flexibility and enhanced stability in both water and ethanol. The modified PET films with structural colors from thin-film interference and photoluminescence from QDs can be used in anti-counterfeiting applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr03039d
NASA Astrophysics Data System (ADS)
Bergmann, Helmar; Dobrozemsky, Georg; Minear, Gregory; Nicoletti, Rudolf; Samal, Martin
2005-05-01
An inter-laboratory comparison study was conducted to assess the image quality of PET scanners in Austria. The survey included both dedicated PET scanners (D-PET, n = 8) and coincidence cameras (GC-PET, n = 7). Measurement of image quality was based on the NEMA (National Electrical Manufacturers Association) NU 2-2001 protocol and the IEC (International Electrotechnical Commission) body phantom. The latter contains six fillable spheres ranging in diameter from 37 mm down to 10 mm and a 'lung' insert. The two largest lesions L1-2 simulate cold lesions, the four smaller ones (L3-6) are filled with 18F and activity concentration ratios relative to background of 8:1 and 4:1, respectively. Acquisition and reconstruction in the study employed the participating institutes' standard oncological processing protocol. Calculation of contrast of the spheres was performed with a fully automated procedure. Contrast quality indices (CQIs) reflecting global performance were obtained by summing individual contrast values. Other image quality parameters calculated according to the NEMA protocol were background variability and relative error for correction of attenuation and scatter. Contrast values obtained were 61 ± 16 and 37 ± 14 for L1 (per cent contrast ± SD for D-PET and GC-PET, respectively), 57 ± 16 and 29 ± 16 for L2, 46 ± 10 and 26 ± 6.3 for L3, 37 ± 10 and 15 ± 4.3 for L4, 26 ± 11.5 and 6.1 ± 2.5 for L5, 14 ± 7.1 and 2.6 ± 2.6 for L6, with D-PET systems consistently being superior to GC-PET systems. CQIs permitted ranking of the scanners, also demonstrating a clear distinction between D-PET and GC-PET systems. Background variability was largest for GC-PET systems; the relative error of attenuation and scatter correction was significantly correlated with image quality for D-PET systems only. The study demonstrated considerable differences in image quality not only between GC-PET and D-PET systems but also between individual D-PET systems with possible consequences for clinical interpretation of images and measurement of quantitative indices such as the standardized uptake value. The study provided valuable feedback to the participants as well as baseline data for improving interchangeability of PET images and of quantitative indices between different laboratories.
Huisingh, Carrie; Levitan, Emily B; Irvin, Marguerite R; Owsley, Cynthia; McGwin, Gerald
2016-03-01
Distracted driving is a major cause of motor vehicle collision (MVC) involvement. Pets have been identified as potential distraction to drivers, particularly in the front. This type of distraction could be worse for those with impairment in the cognitive aspects of visual processing. The purpose of this study is to evaluate the association between driving with pets and rates of motor vehicle collision involvement in a cohort of older drivers. A three-year prospective study was conducted in a population-based sample of 2000 licensed drivers aged 70 years and older. At the baseline visit, a trained interviewer asked participants about pet ownership, whether they drive with pets, how frequently, and where the pet sits in the vehicle. Motor vehicle collision (MVC) involvement during the three-year study period was obtained from the Alabama Department of Public Safety. At-fault status was determined by the police officer who arrived on the scene. Participants were followed until the earliest of death, driving cessation, or end of the study period. Poisson regression was used to calculate crude and adjusted rate ratios (RR) examining the association between pet ownership, presence of a pet in a vehicle, frequency of driving with a pet, and location of the pet inside with vehicle with any and at-fault MVC involvement. We examined whether the associations differed by higher order visual processing impairment status, as measured by Useful Field of View, Trails B, and Motor-free Visual Perception Test. Rates of crash involvement were similar for older adults who have ever driven with a pet compared to those who never drove with their pet (RR=1.15, 95% CI 0.76-1.75). Drivers who reported always or sometimes driving with their pet had higher MVC rates compared to pet owners who never drive with a pet, but this association was not statistically significant (RR=1.39, 95% CI 0.86-2.24). In terms of location, those reporting having a pet frequently ride in the front of the vehicle had similar rates of MVC involvement compared to those who did not drive with a pet in the front. A similar pattern of results was observed for at-fault MVCs. This association was not modified by visual processing impairment status. The current study demonstrates a positive but non-significant association between frequently driving with pets and MVC involvement. More research is needed, particularly on restraint use and whether the pet was in the car at the time of the crash, to help characterize the public safety benefit of regulations on driving with pets. Copyright © 2015 Elsevier Ltd. All rights reserved.
Perk, Lars R; Stigter-van Walsum, Marijke; Visser, Gerard W M; Kloet, Reina W; Vosjan, Maria J W D; Leemans, C René; Giaccone, Giuseppe; Albano, Raffaella; Comoglio, Paolo M; van Dongen, Guus A M S
2008-10-01
Targeting the c-Met receptor with monoclonal antibodies (MAbs) is an appealing approach for cancer diagnosis and treatment because this receptor plays a prominent role in tumour invasion and metastasis. Positron emission tomography (PET) might be a powerful tool for guidance of therapy with anti-Met MAbs like the recently described MAb DN30 because it allows accurate quantitative imaging of tumour targeting (immuno-PET). We considered the potential of PET with either (89)Zr-labelled (residualising radionuclide) or (124)I-labelled (non-residualising radionuclide) DN30 for imaging of Met-expressing tumours. The biodistribution of co-injected (89)Zr-DN30 and iodine-labelled DN30 was compared in nude mice bearing either the human gastric cancer line GLT-16 (high Met expression) or the head-and-neck cancer line FaDu (low Met expression). PET images were acquired in both xenograft models up to 4 days post-injection (p.i.) and used for quantification of tumour uptake. Biodistribution studies in GTL-16-tumour-bearing mice revealed that (89)Zr-DN30 achieved much higher tumour uptake levels than iodine-labelled DN30 (e.g. 19.6%ID/g vs 5.3%ID/g, 5 days p.i.), while blood levels were similar, indicating internalisation of DN30. Therefore, (89)Zr-DN30 was selected for PET imaging of GLT-16-bearing mice. Tumours as small as 11 mg were readily visualised with immuno-PET. A distinctive lower (89)Zr uptake was observed in FaDu compared to GTL-16 xenografts (e.g. 7.8%ID/g vs 18.1%ID/g, 3 days p.i.). Nevertheless, FaDu xenografts were also clearly visualised with (89)Zr-DN30 immuno-PET. An excellent correlation was found between PET-image-derived (89)Zr tumour uptake and ex-vivo-assessed (89)Zr tumour uptake (R(2)=0.98). The long-lived positron emitter (89)Zr seems attractive for PET-guided development of therapeutic anti-c-Met MAbs.
The influence of CT based attenuation correction on PET/CT registration: an evaluation study
NASA Astrophysics Data System (ADS)
Yaniv, Ziv; Wong, Kenneth H.; Banovac, Filip; Levy, Elliot; Cleary, Kevin
2007-03-01
We are currently developing a PET/CT based navigation system for guidance of biopsies and radiofrequency ablation (RFA) of early stage hepatic tumors. For these procedures, combined PET/CT data can potentially improve current interventions. The diagnostic efficacy of biopsies can potentially be improved by accurately targeting the region within the tumor that exhibits the highest metabolic activity. For RFA procedures the system can potentially enable treatment of early stage tumors, targeting tumors before structural abnormalities are clearly visible on CT. In both cases target definition is based on the metabolic data (PET), and navigation is based on the spatial data (CT), making the system highly dependent upon accurate spatial alignment between these data sets. In our institute all clinical data sets include three image volumes: one CT, and two PET volumes, with and without CT-based attenuation correction. This paper studies the effect of the CT-based attenuation correction on the registration process. From comparing the pairs of registrations from five data sets we observe that the point motion magnitude difference between registrations is on the same scale as the point motion magnitude in each one of the registrations, and that visual inspection cannot identify this discrepancy. We conclude that using non-rigid registration to align the PET and CT data sets is too variable, and most likely does not provide sufficient accuracy for interventional procedures.
PET scanning in head and neck oncology: a review.
McGuirt, W F; Greven, K; Williams, D; Keyes, J W; Watson, N; Cappellari, J O; Geisinger, K R
1998-05-01
The objective of this study was to review and describe the usage of fluorine-labeled deoxyglucose (FDG) and positron emission tomography (PET) in the diagnosis and management of head and neck cancer. Several prospective series,-including 159 newly diagnosed and previously untreated and 23 previously irradiated head and neck squamous cell carcinoma patients initially seen at the Wake Forest University Medical Center and evaluated by clinical examination, conventional computed tomography/ magnetic resonance imaging (CT/MRI) scans, PET scans, and histopathologic studies,-were reviewed and the findings summarized for comparison of the correct differentiation of primary and metastatic cancers and for postirradiation tumor clearance in a subsegment of those cases. Positron emission tomography scanning using a fluorine-labeled deoxyglucose (FDG) radiotracer proved as reliable as conventional scanning for primary and metastatic tumor identification. Compared with clinical examination, PET was better for identification of nodal metastatic tumors but poorer for small primary tumors. For previously irradiated patients treated at least 4 months before the test, PET scanning was clearly superior to clinical examination and conventional imaging in differentiating tumor recurrence from soft-tissue irradiation effects. Fluorine-labeled deoxyglucose-PET scanning is comparable to conventional imaging of head and neck cancers in detecting primary and metastatic carcinoma. Lack of anatomic detail remains its major drawback. Currently, its greatest role is in the evaluation of the postradiotherapy patient.
Detection of muscarinic receptors in the human lung using PET.
Visser, T J; van Waarde, A; van der Mark, T W; Kraan, J; Ensing, K; Willemsen, A T; Elsinga, P H; Vaalburg, W
1999-08-01
The characterization of pulmonary muscarinic receptors with PET is still in its infancy. Because approximately 70% of the lungs consists of air and pulmonary muscarinic receptor densities are low, ligands with high receptor affinity are required to obtain reasonable signal-to-noise ratios on PET images. Therefore, the potent 11C-labeled muscarinic antagonist N-methyl-piperidin-4-yl 2-cyclohexyl-2-hydroxy-2-phenylacetate methiodide ([R]-VC-002) was developed. We administered this radioligand to four healthy human volunteers to examine its suitability for studying pulmonary muscarinic receptors in vivo. [11C]VC-002 (185 MBq, specific activity > 7.4 TBq/mmol) was intravenously injected on 2 separate days, with an interval of at least 1 wk. On the first day the volunteers were not pretreated, but on the second day they received the anticholinergic glycopyrronium bromide (Robinul; 2 x 0.1 mg intravenous) 25 and 30 min before the injection of the radiopharmaceutical. C[15O]O scans (approximately 740 MBq [20 mCi] by inhalation) were acquired before the receptor scan to calculate pulmonary blood volume. On PET images of the thorax, the lungs were clearly visible. After the volunteer was pretreated with glycopyrronium bromide, pulmonary uptake of the radioligand was reduced to 32%+/-12% of the control value at 60 min postinjection and the lungs could no longer be seen. (R)-[11C]-VC-002 was rapidly cleared from plasma and was slowly metabolized during the time course (60 min) of the PET scan. The fraction of radioligand representing parent compound decreased from 99.9% at the time of injection to 82% at 40-60 min postinjection, both in the presence and absence of Robinul. Pulmonary tissue-to-plasma ratios, calculated on a count-per-minute-per-gram basis, reached a plateau value of 17.8+/-1.2 at 40-50 min postinjection. [11C]VC-002 appears to be suitable for in vivo studies of pulmonary cholinoceptors.
18F-FDG PET radiomics approaches: comparing and clustering features in cervical cancer.
Tsujikawa, Tetsuya; Rahman, Tasmiah; Yamamoto, Makoto; Yamada, Shizuka; Tsuyoshi, Hideaki; Kiyono, Yasushi; Kimura, Hirohiko; Yoshida, Yoshio; Okazawa, Hidehiko
2017-11-01
The aims of our study were to find the textural features on 18 F-FDG PET/CT which reflect the different histological architectures between cervical cancer subtypes and to make a visual assessment of the association between 18 F-FDG PET textural features in cervical cancer. Eighty-three cervical cancer patients [62 squamous cell carcinomas (SCCs) and 21 non-SCCs (NSCCs)] who had undergone pretreatment 18 F-FDG PET/CT were enrolled. A texture analysis was performed on PET/CT images, from which 18 PET radiomics features were extracted including first-order features such as standardized uptake value (SUV), metabolic tumor volume (MTV) and total lesion glycolysis (TLG), second- and high-order textural features using SUV histogram, normalized gray-level co-occurrence matrix (NGLCM), and neighborhood gray-tone difference matrix, respectively. These features were compared between SCC and NSCC using a Bonferroni adjusted P value threshold of 0.0028 (0.05/18). To assess the association between PET features, a heat map analysis with hierarchical clustering, one of the radiomics approaches, was performed. Among 18 PET features, correlation, a second-order textural feature derived from NGLCM, was a stable parameter and it was the only feature which showed a robust trend toward significant difference between SCC and NSCC. Cervical SCC showed a higher correlation (0.70 ± 0.07) than NSCC (0.64 ± 0.07, P = 0.0030). The other PET features did not show any significant differences between SCC and NSCC. A higher correlation in SCC might reflect higher structural integrity and stronger spatial/linear relationship of cancer cells compared with NSCC. A heat map with a PET feature dendrogram clearly showed 5 distinct clusters, where correlation belonged to a cluster including MTV and TLG. However, the association between correlation and MTV/TLG was not strong. Correlation was a relatively independent PET feature in cervical cancer. 18 F-FDG PET textural features might reflect the differences in histological architecture between cervical cancer subtypes. PET radiomics approaches reveal the association between PET features and will be useful for finding a single feature or a combination of features leading to precise diagnoses, potential prognostic models, and effective therapeutic strategies.
Public health implications of animals in retail food outlets.
Dyjack, David T; Ho, Jessica; Lynes, Rahel; Lynes, Rachel; Bliss, Jesse C
2013-12-01
Growing societal interest to permit animals into retail food outlets presents both risks and benefits to the dining public and consumers. This article summarizes a literature review that evaluated the associated potential public health issues related to this subject. Using the EBSCOhost research protocol and Google search engines between March 2010 and June 2011, the authors have compiled and synthesized scientific research articles, empirical scientific literature, and publicly available news media. While pets are known carriers of bacteria and parasites, among others, the relative risk associated with specific pet-human interactions in the dining public has yet to be established in a clear and consistent manner. Much of the available health-risk-factor evidence reflects pets in domestic conditions and interaction with farm animals. Special consideration is recommended for vulnerable populations such as children, asthmatics, the elderly, pregnant women, and the immunocompromised.
What approach to brain partial volume correction is best for PET/MRI?
NASA Astrophysics Data System (ADS)
Hutton, B. F.; Thomas, B. A.; Erlandsson, K.; Bousse, A.; Reilhac-Laborde, A.; Kazantsev, D.; Pedemonte, S.; Vunckx, K.; Arridge, S. R.; Ourselin, S.
2013-02-01
Many partial volume correction approaches make use of anatomical information, readily available in PET/MRI systems but it is not clear what approach is best. Seven novel approaches to partial volume correction were evaluated, including several post-reconstruction methods and several reconstruction methods that incorporate anatomical information. These were compared with an MRI-independent approach (reblurred van Cittert ) and uncorrected data. Monte Carlo PET data were generated for activity distributions representing both 18F FDG and amyloid tracer uptake. Post-reconstruction methods provided the best recovery with ideal segmentation but were particularly sensitive to mis-registration. Alternative approaches performed better in maintaining lesion contrast (unseen in MRI) with good noise control. These were also relatively insensitive to mis-registration errors. The choice of method will depend on the specific application and reliability of segmentation and registration algorithms.
Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik
2015-01-01
Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson's disease (PD). We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P < 0.0001). Putaminal SUVR values were highly effective for discriminating PD patients from controls. However, the PET-guided method excessively overestimated striatal SUVR values in the PD patients by more than 30% in caudate and putamen, and thereby spoiled the linearity between the striatal SUVR values in all subjects and showed lower disease discrimination ability. Two CT-guided methods showed comparable capability with the MR-guided methods in separating PD patients from controls and showed better correlation between putaminal SUVR values and the parkinsonian motor severity than the PET-guided method. CT-guided spatial normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable.
Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik
2015-01-01
Background Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson’s disease (PD). Methods We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. Results The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P < 0.0001). Putaminal SUVR values were highly effective for discriminating PD patients from controls. However, the PET-guided method excessively overestimated striatal SUVR values in the PD patients by more than 30% in caudate and putamen, and thereby spoiled the linearity between the striatal SUVR values in all subjects and showed lower disease discrimination ability. Two CT-guided methods showed comparable capability with the MR-guided methods in separating PD patients from controls and showed better correlation between putaminal SUVR values and the parkinsonian motor severity than the PET-guided method. Conclusion CT-guided spatial normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable. PMID:26147749
Exposure and Sensitization to Pets Modify Endotoxin Association with Asthma and Wheeze.
Mendy, Angelico; Wilkerson, Jesse; Salo, Päivi M; Cohn, Richard D; Zeldin, Darryl C; Thorne, Peter S
2018-04-21
Pets are major contributors of endotoxin in homes, but whether they influence endotoxin association with respiratory outcomes is unclear. To examine whether exposure and sensitization to dog and cat modify the relationship between endotoxin exposure and asthma and wheeze. We analyzed data from 6051 participants in the 2005-2006 cycle of the National Health and Nutrition Examination Survey (NHANES). House dust from bedroom floor and bedding was evaluated for endotoxin and for dog (Canis familiaris 1) and cat (Feline domesticus 1) allergens. The NHANES also collected data on respiratory outcomes and measured IgE specific to allergens. Associations of log-endotoxin and pet exposure with respiratory outcomes were examined, adjusting for covariates including pet avoidance. Dog and cat ownership among participants was 48.3% and 37.5%, respectively. Endotoxin geometric mean (SE) was 15.49 (0.50) EU/mg. Endotoxin and pet allergen levels were significantly higher in households with a dog or cat. Overall, endotoxin was positively associated with wheeze (odds ratio [OR], 1.30; 95% CI, 1.04-1.62), but not with asthma. However, in participants nonsensitized to dog, the odds of endotoxin association with wheeze were higher with exposure to dog allergen (OR, 1.80; 95% CI, 1.27-2.53; P interaction = .048). In participants sensitized to cat and exposed to cat allergen, endotoxin became positively associated with asthma (OR, 1.92; 95% CI, 1.21-3.0; P interaction = .040). With coexposure to dog and cat allergens, endotoxin association with asthma and wheeze was exacerbated (OR, 2.00; 95% CI, 1.04-3.83; P interaction = .012 and OR, 1.88; 95% CI, 1.32-2.66; P interaction = .016, respectively). Exposure to dog and cat allergens enhances the association of endotoxin with asthma and wheeze. Copyright © 2018 American Academy of Allergy, Asthma & Immunology. All rights reserved.
Huisingh, Carrie; Levitan, Emily B.; Irvin, Marguerite R.; Owsley, Cynthia; McGwin, Gerald
2016-01-01
Objective Distracted driving is a major cause of motor vehicle collision (MVC) involvement. Pets have been identified as potential distraction to drivers, particularly in the front. This type of distraction could be worse for those with impairment in the cognitive aspects of visual processing. The purpose of this study is to evaluate the association between driving with pets and rates of motor vehicle collision involvementin a cohort of older drivers. Methods A three-year prospective was conducted in a population-based sample of 2000 licensed drivers aged 70 years and older. At the baseline visit, a trained interviewer asked participants about pet ownership, whether they drive with pets, how frequently, and where the pet sits in the vehicle. Motor vehicle collision (MVC) involvement during the three-year study period was obtained from the Alabama Department of Public Safety. At-fault status was determined by the police officer who arrived on the scene. Participants were followed until the earliest of death, driving cessation, or end of the study period. Poisson regression was used to calculate crude and adjusted rate ratios (RR) examining the association between pet ownership, presence of a pet in a vehicle, frequency of driving with a pet, and location of the pet inside with vehicle with any and at-fault MVC involvement. We examined whether the associations differed by higher order visual processing impairment status, as measured by Useful Field Of View, Trails B, and Motor-free Visual Perception Test. Results Rates of crash involvement were similar for older adults who have ever driven with a pet compared to those who never drove with their pet (RR=1.15, 95% CI 0.76-1.75). Drivers who reported always or sometimes driving with their pet had higherMVC rates compared topet owners who never drive with a pet, but this association was not statistically significant (RR=1.39, 95% CI 0.86-2.24). In terms of location, those reporting having a pet frequently ride in the front of the vehicle had similar rates of MVC involvement compared to those who did not drive with a pet in the front. A similar pattern of results was observed for at-fault MVCs. This association was not modified by visual processing impairment status. Conclusion The current study demonstrates a positive but non-significant association between frequently driving with pets and MVC involvement. More research is needed, particularly on restraint use and whether the pet was in the car at the time of the crash, to help characterize the public safety benefit of regulations on driving with pets. PMID:26774042
Afshar-Oromieh, Ali; Holland-Letz, Tim; Giesel, Frederik L; Kratochwil, Clemens; Mier, Walter; Haufe, Sabine; Debus, Nils; Eder, Matthias; Eisenhut, Michael; Schäfer, Martin; Neels, Oliver; Hohenfellner, Markus; Kopka, Klaus; Kauczor, Hans-Ulrich; Debus, Jürgen; Haberkorn, Uwe
2017-08-01
Since the clinical introduction of 68 Ga-PSMA-11 PET/CT, this imaging method has rapidly spread and is now regarded as a significant step forward in the diagnosis of recurrent prostate cancer (PCa). The aim of this study was to analyse the influence of several variables with possible influence on PSMA ligand uptake in a large cohort. We performed a retrospective analysis of 1007 consecutive patients who were scanned with 68 Ga-PSMA-11 PET/CT (1 h after injection) from January 2014 to January 2017 to detect recurrent disease. Patients with untreated primary PCa or patients referred for PSMA radioligand therapy were excluded. The possible effects of different variables including PSA level and PSA doubling time (PSA DT ), PSA velocity (PSA Vel ), Gleason score (GSC, including separate analysis of GSC 7a and 7b), ongoing androgen deprivation therapy (ADT), patient age and amount of injected activity were evaluated. In 79.5% of patients at least one lesion with characteristics suggestive of recurrent PCa was detected. A pathological (positive) PET/CT scan was associated with PSA level and ADT. GSC, amount of injected activity, patient age, PSA DT and PSA Vel were not associated with a positive PET/CT scan in multivariate analysis. 68 Ga-PSMA-11 PET/CT detects tumour lesions in a high percentage of patients with recurrent PCa. Tumour detection is clearly associated with PSA level and ADT. Only a tendency for an association without statistical significance was found between higher GSC and a higher probability of a pathological PET/CT scan. No associations were found between a pathological 68 Ga-PSMA-11 PET/CT scan and patient age, amount of injected activity, PSA DT or PSA Vel.
Non-local means denoising of dynamic PET images.
Dutta, Joyita; Leahy, Richard M; Li, Quanzheng
2013-01-01
Dynamic positron emission tomography (PET), which reveals information about both the spatial distribution and temporal kinetics of a radiotracer, enables quantitative interpretation of PET data. Model-based interpretation of dynamic PET images by means of parametric fitting, however, is often a challenging task due to high levels of noise, thus necessitating a denoising step. The objective of this paper is to develop and characterize a denoising framework for dynamic PET based on non-local means (NLM). NLM denoising computes weighted averages of voxel intensities assigning larger weights to voxels that are similar to a given voxel in terms of their local neighborhoods or patches. We introduce three key modifications to tailor the original NLM framework to dynamic PET. Firstly, we derive similarities from less noisy later time points in a typical PET acquisition to denoise the entire time series. Secondly, we use spatiotemporal patches for robust similarity computation. Finally, we use a spatially varying smoothing parameter based on a local variance approximation over each spatiotemporal patch. To assess the performance of our denoising technique, we performed a realistic simulation on a dynamic digital phantom based on the Digimouse atlas. For experimental validation, we denoised [Formula: see text] PET images from a mouse study and a hepatocellular carcinoma patient study. We compared the performance of NLM denoising with four other denoising approaches - Gaussian filtering, PCA, HYPR, and conventional NLM based on spatial patches. The simulation study revealed significant improvement in bias-variance performance achieved using our NLM technique relative to all the other methods. The experimental data analysis revealed that our technique leads to clear improvement in contrast-to-noise ratio in Patlak parametric images generated from denoised preclinical and clinical dynamic images, indicating its ability to preserve image contrast and high intensity details while lowering the background noise variance.
... gas company right away. Furnace: Keep the air supply vent clear of obstructions. Replace the furnace filter at least every 3 months when in use. Change it every month if you have allergies or pets. Water heater: Set the temperature no higher than 120 ...
Use of Robotic Pets in Providing Stimulation for Nursing Home Residents with Dementia.
Naganuma, M; Ohkubo, E; Kato, N
2015-01-01
Trial experiments utilized robotic pets to facilitate self-reliance in nursing home residents. A remote-control robot modeled clear and meaningful behaviors to elderly residents. Special attention was paid to its effects on mental and social domains. Employing the robot as a gaze target and center of attention created a cue to initiate a communication channel between residents who normally show no interest in each other. The Sony AIBO robot in this study uses commercially available wireless equipment, and all its components are easily accessible to any medical or welfare institution interested in additional practice of these activities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Girinsky, Théodore; Aupérin, Anne; Ribrag, Vincent
2014-08-01
Purpose: This study examines the role of {sup 18}F-labeled fluorodeoxyglucose positron emission tomography (FDG-PET) in the implementation of involved-node radiation therapy (INRT) in patients treated for clinical stages (CS) I/II supradiaphragmatic Hodgkin lymphoma (HL). Methods and Material: Patients with untreated CS I/II HL enrolled in the randomized EORTC/LYSA/FIL Intergroup H10 trial and participating in a real-time prospective quality assurance program were prospectively included in this study. Data were electronically obtained from 18 French cancer centers. All patients underwent APET-computed tomography (PET-CT) and a post-chemotherapy planning CT scanning. The pre-chemotherapy gross tumor volume (GTV) and the postchemotherapy clinical target volume (CTV) weremore » first delineated on CT only by the radiation oncologist. The planning PET was then co-registered, and the delineated volumes were jointly analyzed by the radiation oncologist and the nuclear medicine physician. Lymph nodes undetected on CT but FDG-avid were recorded, and the previously determined GTV and CTV were modified according to FDG-PET results. Results: From March 2007 to February 2010, 135 patients were included in the study. PET-CT identified at least 1 additional FDG-avid lymph node in 95 of 135 patients (70.4%; 95% confidence interval [CI]: 61.9%-77.9%) and 1 additional lymph node area in 55 of 135 patients (40.7%; 95% CI: 32.4%-49.5%). The mean increases in the GTV and CTV were 8.8% and 7.1%, respectively. The systematic addition of PET to CT led to a CTV increase in 60% of the patients. Conclusions: Pre-chemotherapy FDG-PET leads to significantly better INRT delineation without necessarily increasing radiation volumes.« less
Fat-constrained 18F-FDG PET reconstruction using Dixon MR imaging and the origin ensemble algorithm
NASA Astrophysics Data System (ADS)
Wülker, Christian; Heinzer, Susanne; Börnert, Peter; Renisch, Steffen; Prevrhal, Sven
2015-03-01
Combined PET/MR imaging allows to incorporate the high-resolution anatomical information delivered by MRI into the PET reconstruction algorithm for improvement of PET accuracy beyond standard corrections. We used the working hypothesis that glucose uptake in adipose tissue is low. Thus, our aim was to shift 18F-FDG PET signal into image regions with a low fat content. Dixon MR imaging can be used to generate fat-only images via the water/fat chemical shift difference. On the other hand, the Origin Ensemble (OE) algorithm, a novel Markov chain Monte Carlo method, allows to reconstruct PET data without the use of forward- and back projection operations. By adequate modifications to the Markov chain transition kernel, it is possible to include anatomical a priori knowledge into the OE algorithm. In this work, we used the OE algorithm to reconstruct PET data of a modified IEC/NEMA Body Phantom simulating body water/fat composition. Reconstruction was performed 1) natively, 2) informed with the Dixon MR fat image to down-weight 18F-FDG signal in fatty tissue compartments in favor of adjacent regions, and 3) informed with the fat image to up-weight 18F-FDG signal in fatty tissue compartments, for control purposes. Image intensity profiles confirmed the visibly improved contrast and reduced partial volume effect at water/fat interfaces. We observed a 17+/-2% increased SNR of hot lesions surrounded by fat, while image quality was almost completely retained in fat-free image regions. An additional in vivo experiment proved the applicability of the presented technique in practice, and again verified the beneficial impact of fat-constrained OE reconstruction on PET image quality.
Chen, Kewei; Roontiva, Auttawut; Thiyyagura, Pradeep; Lee, Wendy; Liu, Xiaofen; Ayutyanont, Napatkamon; Protas, Hillary; Luo, Ji Luo; Bauer, Robert; Reschke, Cole; Bandy, Daniel; Koeppe, Robert A; Fleisher, Adam S; Caselli, Richard J; Landau, Susan; Jagust, William J; Weiner, Michael W; Reiman, Eric M
2015-04-01
In this article, we describe an image analysis strategy with improved power for tracking longitudinal amyloid-β (Aβ) PET changes and evaluating Aβ-modifying treatments. Our aims were to compare the power of template-based cerebellar, pontine, and cerebral white matter reference regions to track 24-mo florbetapir standardized uptake value (SUV) ratio (SUVR) changes; to relate those changes to 24-mo clinical declines; and to evaluate Aβ-modifying treatments in Aβ-positive (Aβ+) and Aβ-negative (Aβ-) patients with probable Alzheimer dementia (pAD), in patients with mild cognitive impairment (MCI), in cognitively normal controls (NCs), and in cognitively normal apolipoprotein E4 (APOE4) carriers and noncarriers. We used baseline and follow-up (∼24 mo) florbetapir PET scans from 332 Aβ+ and Aβ- subjects participating in the multicenter Alzheimer's Disease Neuroimaging Initiative. Each of the proposed analyses included 31 pAD patients, 187 MCI patients, and 114 NCs. Cerebral-to-white matter, cerebellar, and pontine SUVRs were characterized in terms of their longitudinal variability; their power to track longitudinal fibrillar Aβ increases in Aβ+ and Aβ- subgroups and cognitively normal APOE4 carriers and noncarriers; the sample sizes needed to detect attenuated accumulation of or clearance of fibrillar Aβ accumulation in randomized clinical trials; and their ability to relate 24-mo fibrillar Aβ increases to clinical declines. As predicted, cerebral-to-white matter SUVR changes were significantly less variable and had significantly greater power to detect 24-mo fibrillar Aβ increases and evaluate Aβ-modifying treatment effects in Aβ+ pAD, MCI, and NC subjects and cognitively normal APOE4 carriers. They were also distinguished by the ability to detect significant associations between 24-mo Aβ increases and clinical declines. A cerebral white matter reference region may improve the power to track longitudinal fibrillar Aβ increases, to characterize their relationship to longitudinal clinical declines, and to evaluate Aβ-modifying treatments in randomized clinical trials. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
18F-FDG PET/CT delayed images with forced diuresis for revaluating abdominopelvic malignancies.
Wang, Hui-Chun; Wang, Zhi-Min; Wang, Yu-Bin; Chen, Xiao-Hong; Cui, Lan-Lan
2017-05-01
The aim of this retrospective study was to evaluate the role of delayed images after forced diuresis coupled with oral hydration in abdominopelvic 18 F-FDG PET/CT. Forty-six patients consisting of 17 urological diseases, 9 gynecological tumors, 18 colorectal malignancies, and 2 cancers of unknown primary site were retrospectively analyzed. All patients who presented with indeterminate or equivocal abdominopelvic foci on standard 18 F-FDG PET/CT underwent a delayed abdominopelvic imaging after administration of 20 mg furosemide intravenously and extra water intake of 500 mL. PET/CT images before and after furosemide were compared with each other and their findings correlated with pathology or clinical follow-up (>6 months). On initial PET/CT, the glucose metabolism characters of lesions were disguised by radioactive urine, or some undetermined 18 F-FDG accumulating foci near the urinary tract appeared. While postdiuretic PET/CT demonstrated an excellent urinary tracer washout, and hypermetabolic lesions could be clearly detected and precisely localized in all cases. On the other hand, the suspected active foci caused by potential stagnation of excreted 18 F-FDG in urinary tract were eliminated. The sensitivity, specificity, and accuracy were 94.4% (34/36), 8/10, 91.3% (42/46), respectively. Furthermore, the additional lesions with surrounding invasion or locoregional metastasis were discovered in 8 of 46 (17.4%) patients only by the delayed images, including 2 gynecological and 6 rectal malignancies. Detection of abdominopelvic malignancies can be improved using delayed 18 F-FDG PET/CT images after a diuretic and oral hydration.
Sciagrà, Roberto; Passeri, Alessandro; Bucerius, Jan; Verberne, Hein J; Slart, Riemer H J A; Lindner, Oliver; Gimelli, Alessia; Hyafil, Fabien; Agostini, Denis; Übleis, Christopher; Hacker, Marcus
2016-07-01
Until recently, PET was regarded as a luxurious way of performing myocardial perfusion scintigraphy, with excellent image quality and diagnostic capabilities that hardly justified the additional cost and procedural effort. Quantitative perfusion PET was considered a major improvement over standard qualitative imaging, because it allows the measurement of parameters not otherwise available, but for many years its use was confined to academic and research settings. In recent years, however, several factors have contributed to the renewal of interest in quantitative perfusion PET, which has become a much more readily accessible technique due to progress in hardware and the availability of dedicated and user-friendly platforms and programs. In spite of this evolution and of the growing evidence that quantitative perfusion PET can play a role in the clinical setting, there are not yet clear indications for its clinical use. Therefore, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, decided to examine the current literature on quantitative perfusion PET to (1) evaluate the rationale for its clinical use, (2) identify the main methodological requirements, (3) identify the remaining technical difficulties, (4) define the most reliable interpretation criteria, and finally (5) tentatively delineate currently acceptable and possibly appropriate clinical indications. The present position paper must be considered as a starting point aiming to promote a wider use of quantitative perfusion PET and to encourage the conception and execution of the studies needed to definitely establish its role in clinical practice.
Rubini, G; Altini, C; Notaristefano, A; Merenda, N; Rubini, D; Ianora, A A Stabile; Asabella, A Niccoli
2014-01-01
To investigate the role of whole-body fluorine-18-2-deoxy-2-fluoro-d-glucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in the identification of peritoneal carcinomatosis in patients with ovarian cancer (OC). Seventy-nine patients with histologically proven stages III-IV OC who underwent (18)F-FDG PET/CT were studied retrospectively. We considered group A as 51 patients who also underwent computed-tomography with contrast-enhancement (CECT), and group B as 35 patients who had also been tested for biomarker Ca-125. Sensitivity, specificity, accuracy, positive predictive values (PPV) and negative predictive values (NPV) of (18)F-FDG PET/CT as compared to CECT and to Ca-125 were evaluated. (18)F-FDG PET/CT' sensitivity, specificity, accuracy, PPV and NPV for all 79 patients were: 85%, 92.31%, 88.61%, 91.89% and 85.71%, respectively. (18)F-FDG PET/CT sensitivity in group A was 78.6%, while it was 53.6% for CECT. (18)F-FDG PET/CT specificity, calculated in the same group, was 91.3%, while that of CECT was 60.9% (statistically significant difference, McNemar 4, P=0.039). Accuracy was 84.3% and 56.9%, respectively. (18)F-FDG PET/CT' sensitivity in group B was 86.4%, while that of Ca-125 was 81.8% (no statistical difference, McNemar 0, P=1). (18)F-FDG PET/CT specificity in group B was 84.6% while that of Ca-125 was 38.5% (clear but not statistically significant difference, McNemar 3.12, P=0.070). Accuracy calculated in the same group was 85.7% for (18)F-FDG PET/CT and 65.7% for Ca-125. (18)F-FDG PET/CT is a useful diagnostic tool when peritoneal biopsy cannot be performed and it can better select those who are candidates for adjuvant chemotherapy. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.
Pre and post PET-CT impact on oesophageal cancer management: a retrospective analysis.
NASA Astrophysics Data System (ADS)
Azmi, NA; Razak, HRA; Vinjamuri, S.
2017-05-01
Assessment of the retrospective cancer incidence, prevalence and crude survival rates of oesophageal cancer to allow comparison between pre and post PET-CT introduction are part of 4 phase cost effectiveness research. It will provide baseline data for to assess PET or PET-CT cost effective potential for staging. A total of 849 patient’s data received from NWCIS databases with various stages of oesophageal cancer between 2001 and 2008. The fundamental activities are retrospective analysis of patient data. In most cases where appropriate, results are presented with 95 percent confidence intervals (CI). Variances between patient groups and variables are assessed using chi-square test. In cases where it deems vital, multiple logistic regression are used to modify for potential confounder such as age and sex. All p-values are two-sided and any value lower than 0.05 were considered to suggest a statistically significant result. Retrospective analysis were categorised into two categories, patients from 2001-2003 considered as pre PET and post PET for 2004-2008. This categorisation allows better comparison of patients’ survival trend to be made between both groups. Rates are presented in percentages and being grouped by tumour characteristics and other variables associated with demographic profile, diagnosis, staging and treatment. Results allowed comparison of oesophageal cancer trends between the pre and post PET-CT introduction such as changes in incidence rate or changes in survival. These data were used to normalise the decision tree model so that cost-effectiveness analysis can be performed across the whole population.
TandemPET-A High Resolution, Small Animal, Virtual Pinhole-Based PET Scanner: Initial Design Study
NASA Astrophysics Data System (ADS)
Raylman, Raymond R.; Stolin, Alexander V.; Martone, Peter F.; Smith, Mark F.
2016-02-01
Mice are the perhaps the most common species of rodents used in biomedical research, but many of the current generation of small animal PET scanners are non-optimal for imaging these small rodents due to their relatively low resolution. Consequently, a number of researchers have investigated the development of high-resolution scanners to address this need. In this investigation, the design of a novel, high-resolution system based on the dual-detector, virtual-pinhole PET concept was explored via Monte Carlo simulations. Specifically, this system, called TandemPET, consists of a 5 cm × 5 cm high-resolution detector made-up of a 90 × 90 array of 0.5 mm × 0.5 × 10 mm (pitch = 0.55 mm) LYSO detector elements in coincidence with a lower resolution detector consisting of a 68 × 68 array of 1.5 mm × 1.5 mm × 10 mm LYSO detector elements (total size = 10.5 cm × 10.5 cm). Analyses indicated that TandemPET's optimal geometry is to position the high-resolution detector 3 cm from the center-of-rotation, with the lower resolution detector positioned 9 cm from center. Measurements using modified NEMA NU4-2008-based protocols revealed that the spatial resolution of the system is 0.5 mm FWHM, after correction of positron range effects. Peak sensitivity is 2.1%, which is comparable to current small animal PET scanners. Images from a digital mouse brain phantom demonstrated the potential of the system for identifying important neurological structures.
Xu, Huan; Hu, Meina; Yu, Xiu; Li, Yan; Fu, Yuanshan; Zhou, Xiaoxia; Zhang, Di; Li, Jianying
2015-04-01
In this study, a novel material, poly(2-ethyl-2-oxazoline)-cholesterol hemisuccinate (PEtOz-CHEMS), was synthesized to construct pH-sensitive liposomes. The structure of PEtOz-CHEMS was confirmed by thin-layer chromatography, Fourier transform infrared spectroscopy, and (1)H NMR. Anticancer fluorescent drug doxorubicin (DOX) was encapsulated into the liposomes. Compared with conventional liposomes (CL), CHEMS modified liposomes (CH-L) and PEGylated liposomes (PEG-L), the PEtOzylated liposomes (PEtOz-L) showed an acidic pH-induced increase in particle size. At pH 6.4, the heme release of PEtOz-L group was close to that of the positive control group, whereas that of CL, CH-L and PEG-L was close to that of the negative control group. In vitro drug release studies demonstrated that DOX was released from PEtOz-L in a pH-dependent manner, and the release of DOX from conventional DOX liposomes (CL-DOX), DOX loaded CH-L (CH-DOX-L) and PEGylated DOX liposomes (PEG-DOX-L) had no pronounced differences under each pH medium. In vitro cellular uptake assays showed that PEtOz-DOX-L indicated a significant fluorescence intensity at pH 6.4 compared with at pH 7.4. CL-DOX, CH-DOX-L and PEG-DOX-L did not achieve any obvious diversity at different pH conditions. Confocal laser scanning microscopy images showed that PEtOz-DOX-L can fuse with the endosomal membrane under acidic conditions of endosome, release DOX into the cytoplasm, then gather into the nucleus. Therefore, PEtOz can help liposomes achieve "endosomal escape". The in vitro cytotoxicity experiment results on A375 cells showed that PEtOz-DOX-L resulted in lower cell viability than CL-DOX, CH-DOX-L and PEG-DOX-L under low pH conditions. These results confirm that the pH-responsive PEtOz was a promising material for intracellular targeted delivery system and might be used for overcoming the "PEG dilemma". Copyright © 2015 Elsevier B.V. All rights reserved.
Ceresoli, Giovanni Luca; Cattaneo, Giovanni Mauro; Castellone, Pietro; Rizzos, Giovanna; Landoni, Claudio; Gregorc, Vanesa; Calandrino, Riccardo; Villa, Eugenio; Messa, Cristina; Santoro, Armando; Fazio, Ferruccio
2007-01-01
Mediastinal elective node irradiation (ENI) in patients with non-small cell lung cancer candidate to radical radiotherapy is controversial. In this study, the impact of co-registered [18F]fluorodeoxyglucose-positron emission tomography (PET) and standard computed tomography (CT) on definition of target volumes and toxicity parameters was evaluated, by comparison with standard CT-based simulation with and without ENI. CT-based gross tumor volume (GTVCT) was first contoured by a single observer without knowledge of PET results. Subsequently, the integrated GTV based on PET/CT coregistered images (GTVPET/CT) was defined. Each patient was planned according to three different treatment techniques: 1) radiotherapy with ENI using the CT data set alone (ENI plan); 2) radiotherapy without ENI using the CT data set alone (no ENI plan); 3) radiotherapy without ENI using PET/CT fusion data set (PET plan). Rival plans were compared for each patient with respect to dose to the normal tissues (spinal cord, healthy lungs, heart and esophagus). The addition of PET-modified TNM staging in 10/21 enrolled patients (48%); 3/21 were shifted to palliative treatment due to detection of metastatic disease or large tumor not amenable to high-dose radiotherapy. In 7/18 (39%) patients treated with radical radiotherapy, a significant (> or =25%) change in volume between GTVCT and GTVPET/CT was observed. For all the organs at risk, ENI plans had dose values significantly greater than no-ENI and PET plans. Comparing no ENI and PET plans, no statistically significant difference was observed, except for maximum point dose to the spinal cord Dmax, which was significantly lower in PET plans. Notably, even in patients in whom PET/CT planning resulted in an increased GTV, toxicity parameters were fairly acceptable, and always more favorable than with ENI plans. Our study suggests that [18F]-fluorodeoxyglucose-PET should be integrated in no-ENI techniques, as it improves target volume delineation without a major increase in predicted toxicity.
NASA Astrophysics Data System (ADS)
Fawzy, Y. H. A.; Abdel-Hamid, H. M.; El-Okr, M. M.; Atta, A.
Polyethylene terephthalate (PET) films with thickness 40μm are irradiated with 3keV argon ion beams with different fluence ranging from 0.5×1018ions.cm-2 to 2×1018ions.cm-2 using locally designed broad ion source. The changes in the PET structure are characterized using X-ray diffraction (XRD), Fourier transform infrared (FTIR) and scanning electron microscope (SEM) techniques. The XRD patterns show that the peak intensity decreases with irradiation and the particle size decreases from 65.75 Å for the un-irradiated to 52.80 Å after irradiation. The FTIR indicates partial decrease and reduction in the intensity of the bands due to the degradation of the polymer after ion irradiation. The optical energy band gap decreases from 3.14eV to 3.05eV and the number of carbon cluster increases from 119 to 126 after ion irradiation. The results show a slight increase in the electrical conductivities and the dielectric constant (ɛ). The results indicate the effectiveness of using PET films as capacitors and resistors in industrial applications.
PET image reconstruction using multi-parametric anato-functional priors
NASA Astrophysics Data System (ADS)
Mehranian, Abolfazl; Belzunce, Martin A.; Niccolini, Flavia; Politis, Marios; Prieto, Claudia; Turkheimer, Federico; Hammers, Alexander; Reader, Andrew J.
2017-08-01
In this study, we investigate the application of multi-parametric anato-functional (MR-PET) priors for the maximum a posteriori (MAP) reconstruction of brain PET data in order to address the limitations of the conventional anatomical priors in the presence of PET-MR mismatches. In addition to partial volume correction benefits, the suitability of these priors for reconstruction of low-count PET data is also introduced and demonstrated, comparing to standard maximum-likelihood (ML) reconstruction of high-count data. The conventional local Tikhonov and total variation (TV) priors and current state-of-the-art anatomical priors including the Kaipio, non-local Tikhonov prior with Bowsher and Gaussian similarity kernels are investigated and presented in a unified framework. The Gaussian kernels are calculated using both voxel- and patch-based feature vectors. To cope with PET and MR mismatches, the Bowsher and Gaussian priors are extended to multi-parametric priors. In addition, we propose a modified joint Burg entropy prior that by definition exploits all parametric information in the MAP reconstruction of PET data. The performance of the priors was extensively evaluated using 3D simulations and two clinical brain datasets of [18F]florbetaben and [18F]FDG radiotracers. For simulations, several anato-functional mismatches were intentionally introduced between the PET and MR images, and furthermore, for the FDG clinical dataset, two PET-unique active tumours were embedded in the PET data. Our simulation results showed that the joint Burg entropy prior far outperformed the conventional anatomical priors in terms of preserving PET unique lesions, while still reconstructing functional boundaries with corresponding MR boundaries. In addition, the multi-parametric extension of the Gaussian and Bowsher priors led to enhanced preservation of edge and PET unique features and also an improved bias-variance performance. In agreement with the simulation results, the clinical results also showed that the Gaussian prior with voxel-based feature vectors, the Bowsher and the joint Burg entropy priors were the best performing priors. However, for the FDG dataset with simulated tumours, the TV and proposed priors were capable of preserving the PET-unique tumours. Finally, an important outcome was the demonstration that the MAP reconstruction of a low-count FDG PET dataset using the proposed joint entropy prior can lead to comparable image quality to a conventional ML reconstruction with up to 5 times more counts. In conclusion, multi-parametric anato-functional priors provide a solution to address the pitfalls of the conventional priors and are therefore likely to increase the diagnostic confidence in MR-guided PET image reconstructions.
Alvarez Moreno, Elena; Jimenez de la Peña, Mar; Cano Alonso, Raquel
2012-01-01
Recent developments in diagnostic imaging techniques have magnified the role and potential of both MRI and PET-CT in female pelvic imaging. This article reviews the techniques and clinical applications of new functional MRI (fMRI) including diffusion-weighted MRI (DWI), dynamic contrast-enhanced (DCE)-MRI, comparing with PET-CT. These new emerging provide not only anatomic but also functional imaging, allowing detection of small volumes of active tumor at diagnosis and early disease relapse, which may not result in detectable morphological changes at conventional imaging. This information is useful in distinguishing between recurrent/residual tumor and post-treatment changes and assessing treatment response, with a clear impact on patient management. Both PET-CT and now fMRI have proved to be very valuable tools for evaluation of gynecologic tumors. Most papers try to compare these techniques, but in our experience both are complementary in management of these patients. Meanwhile PET-CT is superior in diagnosis of ganglionar disease; fMRI presents higher accuracy in local preoperative staging. Both techniques can be used as biomarkers of tumor response and present high accuracy in diagnosis of local recurrence and peritoneal dissemination, with complementary roles depending on histological type, anatomic location and tumoral volume. PMID:22315683
Macis, Giuseppe; Di Giovanni, Silvia; Di Franco, Davide; Bonomo, Lorenzo
2013-01-01
The future approach of diagnostic imaging in urology follows the technological progress, which made the visualization of in vivo molecular processes possible. From anatomo-morphological diagnostic imaging and through functional imaging molecular radiology is reached. Based on molecular probes, imaging is aimed at assessing the in vivo molecular processes, their physiology and function at cellular level. The future imaging will investigate the complex tumor functioning as metabolism, aerobic glycolysis in particular, angiogenesis, cell proliferation, metastatic potential, hypoxia, apoptosis and receptors expressed by neoplastic cells. Methods for performing molecular radiology are CT, MRI, PET-CT, PET-MRI, SPECT and optical imaging. Molecular ultrasound combines technological advancement with targeted contrast media based on microbubbles, this allowing the selective registration of microbubble signal while that of stationary tissues is suppressed. An experimental study was carried out where the ultrasound molecular probe BR55 strictly bound to prostate tumor results in strong enhancement in the early phase after contrast, this contrast being maintained in the late phase. This late enhancement is markedly significant for the detection of prostatic cancer foci and to guide the biopsy sampling. The 124I-cG250 molecular antibody which is strictly linked to cellular carbonic anhydrase IX of clear cell renal carcinoma, allows the acquisition of diagnostic PET images of clear cell renal carcinoma without biopsy. This WG-250 (RENCAREX) antibody was used as a therapy in metastatic clear cell renal carcinoma. Future advancements and applications will result in early cancer diagnosis, personalized therapy that will be specific according to the molecular features of cancer and leading to the development of catheter-based multichannel molecular imaging devices for cystoscopy-based molecular imaging diagnosis and intervention.
Validation of the mean radiant temperature simulated by the RayMan software in urban environments.
Lee, Hyunjung; Mayer, Helmut
2016-11-01
The RayMan software is worldwide applied in investigations on different issues in human-biometeorology. However, only the simulated mean radiant temperature (T mrt ) has been validated so far in a few case studies. They are based on T mrt values, which were experimentally determined in urban environments by use of a globe thermometer or applying the six-directional method. This study analyses previous T mrt validations in a comparative manner. Their results are extended by a recent validation of T mrt in an urban micro-environment in Freiburg (southwest Germany), which can be regarded as relatively heterogeneous due to different shading intensities by tree crowns. In addition, a validation of the physiologically equivalent temperature (PET) simulated by RayMan is conducted for the first time. The validations are based on experimentally determined T mrt and PET values, which were calculated from measured meteorological variables in the daytime of a clear-sky summer day. In total, the validation results show that RayMan is capable of simulating T mrt satisfactorily under relatively homogeneous site conditions. However, the inaccuracy of simulated T mrt is increasing with lower sun elevation and growing heterogeneity of the simulation site. As T mrt represents the meteorological variable that mostly governs PET in the daytime of clear-sky summer days, the accuracy of simulated T mrt is mainly responsible for the accuracy of simulated PET. The T mrt validations result in some recommendations, which concern an update of physical principles applied in the RayMan software to simulate the short- and long-wave radiant flux densities, especially from vertical building walls and tree crowns.
Yang, Meng; Cheng, Kai; Qi, Shibo; Liu, Hongguang; Jiang, Yuxin; Jiang, Han; Li, Jinbo; Chen, Kai; Zhang, Huimao; Cheng, Zhen
2013-01-01
A highly monodispersed hetero-nanostructure with two different functional nanomaterials (gold (Au) and iron oxide (Fe3O4, IO)) within one structure was successfully developed as Affibody based trimodality nanoprobe (positron emission tomography, PET; optical imaging; and magnetic resonance imaging, MRI) for imaging of epidermal growth factor receptor (EGFR) positive tumors. Unlike other regular nanostructures with a single component, the Au-IO hetero-nanostructures (Au-IONPs) with unique chemical and physical properties have capability to combine several imaging modalities together to provide complementary information. The IO component within hetero-nanostructures serve as a T2 reporter for MRI; and gold component serve as both optical and PET reporters. Moreover, such hetero-nanoprobes could provide a robust nano-platform for surface-specific modification with both targeting molecules (anti-EGFR Affibody protein) and PET imaging reporters (radiometal 64Cu chelators) in highly efficient and reliable manner. In vitro and in vivo study showed that the resultant nanoprobe provided high specificity, sensitivity, and excellent tumor contrast for both PET and MRI imaging in the human EGFR-expressing cells and tumors. Our study data also highlighted the EGFR targeting efficiency of hetero-nanoparticles and the feasibility for their further theranostic applications. PMID:23343632
PET Scans Obtained for Evaluation of Cognitive Dysfunction
Silverman, Daniel H. S.; Mosconi, Lisa; Ercoli, Linda; Chen, W; Small, Gary W.
2015-01-01
The degree of intactness of human cognitive functioning for a given individual spans a wide spectrum, ranging from normal to severely demented. The differential diagnosis for the causes of impairment along that spectrum is also wide, and often difficult to distinguish clinically, which has led to an increasing role for neuroimaging tools in that evaluation. The most frequent causes of dementia are neurodegenerative disorders, Alzheimer's disease being the most prevalent among them, and they produce significant alterations in brain metabolism with devastating neuropathologic, economic, social and clinical consequences. These alterations are detectable through positron emission tomography (PET), even in their earliest stages. The most commonly performed PET studies of the brain are carried out with [18F]fluorodeoxyglucose (FDG) as the imaged radiopharmaceutical. Such scans have demonstrated diagnostic and prognostic utility in evaluating patients with cognitive impairment, and in distinguishing among primary neurodegenerative disorders and other etiologies for cognitive decline. In addition to focusing upon the effects on cerebral metabolism examined with FDG PET, some other changes occurring in the brains of cognitively impaired patients assessable with other radiotracers will be considered. As preventive and disease-modifying treatments are developed, early detection of accurately diagnosed disease processes facilitated by the use of PET has the potential to substantially impact upon the enormous human toll exacted by these diseases. PMID:18514081
Vallabhajosula, Shankar
2007-11-01
Molecular imaging is the visualization, characterization, and measurement of biological processes at the molecular and cellular levels in a living system. At present, positron emission tomography/computed tomography (PET/CT) is one the most rapidly growing areas of medical imaging, with many applications in the clinical management of patients with cancer. Although [(18)F]fluorodeoxyglucose (FDG)-PET/CT imaging provides high specificity and sensitivity in several kinds of cancer and has many applications, it is important to recognize that FDG is not a "specific" radiotracer for imaging malignant disease. Highly "tumor-specific" and "tumor cell signal-specific" PET radiopharmaceuticals are essential to meet the growing demand of radioisotope-based molecular imaging technology. In the last 15 years, many alternative PET tracers have been proposed and evaluated in preclinical and clinical studies to characterize the tumor biology more appropriately. The potential clinical utility of several (18)F-labeled radiotracers (eg, fluoride, FDOPA, FLT, FMISO, FES, and FCH) is being reviewed by several investigators in this issue. An overview of design and development of (18)F-labeled PET radiopharmaceuticals, radiochemistry, and mechanism(s) of tumor cell uptake and localization of radiotracers are presented here. The approval of clinical indications for FDG-PET in the year 2000 by the Food and Drug Administration, based on a review of literature, was a major breakthrough to the rapid incorporation of PET into nuclear medicine practice, particularly in oncology. Approval of a radiopharmaceutical typically involves submission of a "New Drug Application" by a manufacturer or a company clearly documenting 2 major aspects of the drug: (1) manufacturing of PET drug using current good manufacturing practices and (2) the safety and effectiveness of a drug with specific indications. The potential routine clinical utility of (18)F-labeled PET radiopharmaceuticals depends also on regulatory compliance in addition to documentation of potential safety and efficacy by various investigators.
Gil, Tae Young; Lee, Do Kyung; Lee, Jung Min; Yoo, Eun Sun; Ryu, Kyung-Ha
2014-06-01
To evaluate the potential utility of (123)I-metaiodobenzylguanine ((123)I-MIBG) scintigraphy and (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) for the detection of primary and metastatic lesions in pediatric neuroblastoma (NBL) patients, and to determine whether (18)F-FDG PET is as beneficial as (123)I-MIBG imaging. We selected 8 NBL patients with significant residual mass after operation and who had paired (123)I-MIBG and (18)F-FDG PET images that were obtained during the follow-up. We retrospectively reviewed the clinical charts and the findings of 45 paired scans. Both scans correlated relatively well with the disease status as determined by standard imaging modalities during follow-up; the overall concordance rates were 32/45 (71.1%) for primary tumor sites and 33/45 (73.3%) for bone-bone marrow (BM) metastatic sites. In detecting primary tumor sites, (123)I-MIBG might be superior to (18)F-FDG PET. The sensitivity of (123)I-MIBG and (18)F-FDG PET were 96.7% and 70.9%, respectively, and their specificity were 85.7% and 92.8%, respectively. (18)F-FDG PET failed to detect 9 true NBL lesions in 45 follow-up scans (false negative rate, 29%) with positive (123)I-MIBG. For bone-BM metastatic sites, the sensitivity of (123)I-MIBG and (18)F-FDG PET were 72.7% and 81.8%, respectively, and the specificity were 79.1% and 100%, respectively. (123)I-MIBG scan showed higher false positivity (20.8%) than (18)F-FDG PET (0%). (123)I-MIBG is superior for delineating primary tumor sites, and (18)F-FDG PET could aid in discriminating inconclusive findings on bony metastatic NBL. Both scans can be complementarily used to clearly determine discrepancies or inconclusive findings on primary or bone-BM metastatic NBL during follow-up.
Development of capacitive multiplexing circuit for SiPM-based time-of-flight (TOF) PET detector
NASA Astrophysics Data System (ADS)
Choe, Hyeok-Jun; Choi, Yong; Hu, Wei; Yan, Jianhua; Jung, Jin Ho
2017-04-01
There has been great interest in developing a time-of-flight (TOF) PET to improve the signal-to-noise ratio of PET image relative to that of non-TOF PET. Silicon photomultiplier (SiPM) arrays have attracted attention for use as a fast TOF PET photosensor. Since numerous SiPM arrays are needed to construct a modern human PET, a multiplexing method providing both good timing performance and high channel reduction capability is required to develop a SiPM-based TOF PET. The purpose of this study was to develop a capacitive multiplexing circuit for the SiPM-based TOF PET. The proposed multiplexing circuit was evaluated by measuring the coincidence resolving time (CRT) and the energy resolution as a function of the overvoltage using three different capacitor values of 15, 30, and 51 pF. A flood histogram was also obtained and quantitatively assessed. Experiments were performed using a 4× 4 array of 3× 3 mm2 SiPMs. Regarding the capacitor values, the multiplexing circuit using a smaller capacitor value showed the best timing performance. On the other hand, the energy resolution and flood histogram quality of the multiplexing circuit deteriorated as the capacitor value became smaller. The proposed circuit was able to achieve a CRT of 260+/- 4 ps FWHM and an energy resolution of 17.1 % with a pair of 2× 2× 20 mm3 LYSO crystals using a capacitor value of 30 pF at an overvoltage of 3.0 V. It was also possible to clearly resolve a 6× 6 array of LYSO crystals in the flood histogram using the multiplexing circuit. The experiment results indicate that the proposed capacitive multiplexing circuit is useful to obtain an excellent timing performance and a crystal-resolving capability in the flood histogram with a minimal degradation of the energy resolution, as well as to reduce the number of the readout channels of the SiPM-based TOF PET detector.
PET/MRI of metabolic activity in osteoarthritis: A feasibility study.
Kogan, Feliks; Fan, Audrey P; McWalter, Emily J; Oei, Edwin H G; Quon, Andrew; Gold, Garry E
2017-06-01
To evaluate positron emission tomography / magnetic resonance imaging (PET/MRI) knee imaging to detect and characterize osseous metabolic abnormalities and correlate PET radiotracer uptake with osseous abnormalities and cartilage degeneration observed on MRI. Both knees of 22 subjects with knee pain or injury were scanned at one timepoint, without gadolinium, on a hybrid 3.0T PET-MRI system following injection of 18 F-fluoride or 18 F-fluorodeoxyglucose (FDG). A musculoskeletal radiologist identified volumes of interest (VOIs) around bone abnormalities on MR images and scored bone marrow lesions (BMLs) and osteophytes using a MOAKS scoring system. Cartilage appearance adjacent to bone abnormalities was graded with MRI-modified Outerbridge classifications. On PET standardized uptake values (SUV) maps, VOIs with SUV greater than 5 times the SUV in normal-appearing bone were identified as high-uptake VOI (VOI High ). Differences in 18 F-fluoride uptake between bone abnormalities, BML, and osteophyte grades and adjacent cartilage grades on MRI were identified using Mann-Whitney U-tests. SUV max in all subchondral bone lesions (BML, osteophytes, sclerosis) was significantly higher than that of normal-appearing bone on MRI (P < 0.001 for all). Of the 172 high-uptake regions on 18 F-fluoride PET, 63 (37%) corresponded to normal-appearing subchondral bone on MRI. Furthermore, many small grade 1 osteophytes (40 of 82 [49%]), often described as the earliest signs of osteoarthritis (OA), did not show high uptake. Lastly, PET SUV max in subchondral bone adjacent to grade 0 cartilage was significantly lower compared to that of grades 1-2 (P < 0.05) and grades 3-4 cartilage (P < 0.001). PET/MRI can simultaneously assess multiple early metabolic and morphologic markers of knee OA across multiple tissues in the joint. Our findings suggest that PET/MR may detect metabolic abnormalities in subchondral bone, which appear normal on MRI. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;45:1736-1745. © 2016 International Society for Magnetic Resonance in Medicine.
Recyclability assessment of nano-reinforced plastic packaging.
Sánchez, C; Hortal, M; Aliaga, C; Devis, A; Cloquell-Ballester, V A
2014-12-01
Packaging is expected to become the leading application for nano-composites by 2020 due to the great advantages on mechanical and active properties achieved with these substances. As novel materials, and although there are some current applications in the market, there is still unknown areas under development. One key issue to be addressed is to know more about the implications of the nano-composite packaging materials once they become waste. The present study evaluates the extrusion process of four nanomaterials (Layered silicate modified nanoclay (Nanoclay1), Calcium Carbonate (CaCO3), Silver (Ag) and Zinc Oxide (ZnO) as part of different virgin polymer matrices of polyethylene (PE), Polypropylene (PP) and Polyethyleneterephtalate (PET). Thus, the following film plastic materials: (PE-Nanoclay1, PE-CaCO3, PP-Ag, PET-ZnO, PET-Ag, PET-Nanoclay1) have been processed considering different recycling scenarios. Results on recyclability show that for PE and PP, in general terms and except for some minor variations in yellowness index, tensile modulus, tensile strength and tear strength (PE with Nanoclay1, PP with Ag), the introduction of nanomaterial in the recycling streams for plastic films does not affect the final recycled plastic material in terms of mechanical properties and material quality compared to conventional recycled plastic. Regarding PET, results show that the increasing addition of nanomaterial into the recycled PET matrix (especially PET-Ag) could influence important properties of the recycled material, due to a slight degradation of the polymer, such as increasing pinholes, degradation fumes and elongation at break. Moreover, it should be noted that colour deviations were visible in most of the samples (PE, PP and PET) in levels higher than 0.3 units (limit perceivable by the human eye). The acceptance of these changes in the properties of recycled PE, PP and PET will depend on the specific applications considered (e.g. packaging applications are more strict in material quality that urban furniture or construction products). Copyright © 2014 Elsevier Ltd. All rights reserved.
Optimization in expression and purification of modified apoptin as selective anti-cancer therapy
NASA Astrophysics Data System (ADS)
Sahlan, Muhamad; Wiseso, Anggoro; Hermansyah, Heri; Yohda, Masafumi
2017-02-01
Cancer is a disease caused by abnormal growth of tissue cells of the body that turn into cancer cells. Apoptin from Chicken Anemia Virus is known to have the ability to trigger apoptosis in cancer cells in vitro and in vivo, but not in normal cells. The production of Apoptin was done on Escherichia coli via plasmid pET9a and modified to improve the efficiency and ease of purification using IMAC nickel, by adding a few tags and cleavage site. The expected result is modified Apoptin and evidence of proteins expressed through SDS-PAGE analysis.
Biocompatible inorganic nanoparticles for [18F]-fluoride binding with applications in PET imaging
Jauregui-Osoro, Maite; Williamson, Peter A.; Glaria, Arnaud; Sunassee, Kavitha; Charoenphun, Putthiporn; Green, Mark A.; Mullen, Gregory E. D.; Blower, Philip J.
2014-01-01
A wide selection of insoluble nanoparticulate metal salts was screened for avid binding of [18F]-fluoride. Hydroxyapatite and aluminium hydroxide nanoparticles showed particularly avid and stable binding of [18F]-fluoride in various biological media. The in vivo behaviour of the [18F]-labelled hydroxyapatite and aluminium hydroxide particles was determined by PET-CT imaging in mice. [18F]-labelled hydroxyapatite was stable in circulation and when trapped in various tissues (lung embolisation, subcutaneous and intramuscular), but accumulation in liver via reticuloendothelial clearance was followed by gradual degradation and release of [18F]-fluoride (over a period of 4 h) which accumulated in bone. [18F]-labelled aluminium hydroxide was also cleared to liver and spleen but degraded slightly even without liver uptake (subcutanenous and intramuscular). Both materials have properties that are an attractive basis for the design of molecular targeted PET imaging agents labelled with 18F. PMID:21394352
Similar clinical and neuroimaging features in monozygotic twin pair with mutation in progranulin
McDade, E.; Burrus, T.M.; Boot, B.P.; Kantarci, K.; Fields, J.; Lowe, V.J.; Peller, P.; Knopman, D.; Baker, M.; Finch, N.; Rademakers, R.; Petersen, R.
2012-01-01
Objective: To report the phenotypic characterization of monozygotic twins with mutations encoding progranulin (PGRN). Methods: We studied a twin pair with an exon 4 gene deletion in the PGRN gene. Both twins had clinical and neuropsychological examinations as well as structural MRI and fluorodeoxyglucose PET (FDG-PET) scans. PGRN gene sequencing was performed followed by progranulin ELISA in plasma. Results: Both twins manifested symptoms within 3 years of each other, with early behavioral, language, dysexecutive, and memory problems. MRI and FDG-PET imaging demonstrated a strikingly similar topography of findings with clear left hemisphere predominance. Serum progranulin levels in both were well below those from a normal population sample. Conclusions: Compared with the heterogeneity seen in many families with PGRN mutations, these monozygotic twins demonstrated strong clinical, neuroimaging, and serum progranulin level similarities, demonstrating the importance of shared genetic profiles beyond environmental influences in the symptomatic expression of the disease. PMID:22491866
Teaching Air Pollution in an Authentic Context
NASA Astrophysics Data System (ADS)
Mandrikas, Achilleas; Stavrou, Dimitrios; Skordoulis, Constantine
2017-04-01
This paper describes a teaching-learning sequence (TLS) about air pollution and the findings resulting from its implementation by pre-service elementary teachers (PET) currently undergraduate students of the Department of Primary Education in the National and Kapodistrian University of Athens, Greece. The TLS focused on the relation of air pollution with wind and topography in local conditions. An authentic context was provided to the students based on daily up-to-date meteorological data via the Internet in order to estimate air pollution. The results are encouraging given that PET can correlate wind and concentration of air pollutants through reading specialized angular diagrams and weather maps, can recognize the correlation of topography in the concentration of air pollutants, and can describe temperature inversion. However, the PET demonstrated clear difficulties in ability of orientation, in wind naming, and in interpretation of symbols on weather map. Finally, the implications on teaching air pollution are discussed.
Living with the animals: animal or robotic companions for the elderly in smart homes?
Preuß, Dirk; Legal, Friederike
2017-06-01
Although the use of pet robots in senior living facilities and day-care centres, particularly for individuals suffering from dementia, has been intensively researched, the question of introducing pet robots into domestic settings has been relatively neglected. Ambient assisted living (AAL) offers many interface opportunities for integrating motorised companions. There are diverse medical reasons, as well as arguments from animal ethics, that support the use of pet robots in contrast to living with live animals. However, as this paper makes clear, we should not lose sight of the option of living with animals at home for as long as possible and in conformity with the welfare of the animal assisted by AAL technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Studies of a Next-Generation Silicon-Photomultiplier-Based Time-of-Flight PET/CT System.
Hsu, David F C; Ilan, Ezgi; Peterson, William T; Uribe, Jorge; Lubberink, Mark; Levin, Craig S
2017-09-01
This article presents system performance studies for the Discovery MI PET/CT system, a new time-of-flight system based on silicon photomultipliers. System performance and clinical imaging were compared between this next-generation system and other commercially available PET/CT and PET/MR systems, as well as between different reconstruction algorithms. Methods: Spatial resolution, sensitivity, noise-equivalent counting rate, scatter fraction, counting rate accuracy, and image quality were characterized with the National Electrical Manufacturers Association NU-2 2012 standards. Energy resolution and coincidence time resolution were measured. Tests were conducted independently on two Discovery MI scanners installed at Stanford University and Uppsala University, and the results were averaged. Back-to-back patient scans were also performed between the Discovery MI, Discovery 690 PET/CT, and SIGNA PET/MR systems. Clinical images were reconstructed using both ordered-subset expectation maximization and Q.Clear (block-sequential regularized expectation maximization with point-spread function modeling) and were examined qualitatively. Results: The averaged full widths at half maximum (FWHMs) of the radial/tangential/axial spatial resolution reconstructed with filtered backprojection at 1, 10, and 20 cm from the system center were, respectively, 4.10/4.19/4.48 mm, 5.47/4.49/6.01 mm, and 7.53/4.90/6.10 mm. The averaged sensitivity was 13.7 cps/kBq at the center of the field of view. The averaged peak noise-equivalent counting rate was 193.4 kcps at 21.9 kBq/mL, with a scatter fraction of 40.6%. The averaged contrast recovery coefficients for the image-quality phantom were 53.7, 64.0, 73.1, 82.7, 86.8, and 90.7 for the 10-, 13-, 17-, 22-, 28-, and 37-mm-diameter spheres, respectively. The average photopeak energy resolution was 9.40% FWHM, and the average coincidence time resolution was 375.4 ps FWHM. Clinical image comparisons between the PET/CT systems demonstrated the high quality of the Discovery MI. Comparisons between the Discovery MI and SIGNA showed a similar spatial resolution and overall imaging performance. Lastly, the results indicated significantly enhanced image quality and contrast-to-noise performance for Q.Clear, compared with ordered-subset expectation maximization. Conclusion: Excellent performance was achieved with the Discovery MI, including 375 ps FWHM coincidence time resolution and sensitivity of 14 cps/kBq. Comparisons between reconstruction algorithms and other multimodal silicon photomultiplier and non-silicon photomultiplier PET detector system designs indicated that performance can be substantially enhanced with this next-generation system. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
PET-modified red mud as catalysts for oxidative desulfurization reactions.
do Prado, Nayara T; Heitmann, Ana P; Mansur, Herman S; Mansur, Alexandra A; Oliveira, Luiz C A; de Castro, Cinthia S
2017-07-01
This work describes the synthesis of catalysts based on red mud/polyethylene terephthalate (PET) composites and their subsequent heat treatment under N 2 atmosphere. The materials were characterized by scanning electron microscopy (SEM), temperature programmed reduction (TPR), Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), thermogravimetric (TG) analysis and N 2 adsorption/desorption. The catalysts were evaluated in the oxidative desulfurization reaction of dibenzothiophene (DBT) in a biphasic system. The results indicated that the PET impregnation on red mud increased the affinity of the catalyst with the nonpolar phase (fuel), in which the contaminant was dissolved, allowing a higher conversion (up to 80%) and selectivity to the corresponding dibenzothiophene sulfone. The sulfone compound is more polar than DBT and diffused into the polar solvent as indicated by the data obtained via gas chromatography-mass spectrometry (GC-MS). Copyright © 2017. Published by Elsevier B.V.
Measuring the significance of pearlescence in real-time bottle forming
NASA Astrophysics Data System (ADS)
Nixon, J.; Menary, G.; Yan, S.
2018-05-01
This work examines the optical properties of polyethylene terephthalate (PET) bottles during the stretch-blow-moulding (SBM) process. PET has a relatively large process window with regards to process parameters, however if the boundaries are pushed, the resultant bottle can become insufficient for consumer requirements. One aspect of this process is the onset of pearlescence in the bottle material, where the bottle becomes opaque due to elevated stress whitening. Experimental trials were carried out using a modified free-stretch-blow machine where the deforming bottle was examined in free air. The strain values of the deformation were measured using digital image correlation (DIC) and the optical properties were measured relative to the initial amorphous PET preform. The results reveal that process parameters can significantly affect pearlescence. The detrimental level of pearlescence may be predicted therefore reducing the probability of poorly formed bottles.
Stickel, Jennifer R; Qi, Jinyi; Cherry, Simon R
2007-01-01
With the increasing use of in vivo imaging in mouse models of disease, there are many interesting applications that demand imaging of organs and tissues with submillimeter resolution. Though there are other contributing factors, the spatial resolution in small-animal PET is still largely determined by the detector pixel dimensions. In this work, a pair of lutetium oxyorthosilicate (LSO) arrays with 0.5-mm pixels was coupled to multichannel photomultiplier tubes and evaluated for use as high-resolution PET detectors. Flood histograms demonstrated that most crystals were clearly identifiable. Energy resolution varied from 22% to 38%. The coincidence timing resolution was 1.42-ns full width at half maximum (FWHM). The intrinsic spatial resolution was 0.68-mm FWHM as measured with a 30-gauge needle filled with (18)F. The improvement in spatial resolution in a tomographic setting is demonstrated using images of a line source phantom reconstructed with filtered backprojection and compared with images obtained from 2 dedicated small-animal PET scanners. Finally, a projection image of the mouse foot is shown to demonstrate the application of these 0.5-mm LSO detectors to a biologic task. A pair of highly pixelated LSO detections has been constructed and characterized for use as high-spatial-resolution PET detectors. It appears that small-animal PET systems capable of a FWHM spatial resolution of 600 microm or less are feasible and should be pursued.
3D multiplayer virtual pets game using Google Card Board
NASA Astrophysics Data System (ADS)
Herumurti, Darlis; Riskahadi, Dimas; Kuswardayan, Imam
2017-08-01
Virtual Reality (VR) is a technology which allows user to interact with the virtual environment. This virtual environment is generated and simulated by computer. This technology can make user feel the sensation when they are in the virtual environment. The VR technology provides real virtual environment view for user and it is not viewed from screen. But it needs another additional device to show the view of virtual environment. This device is known as Head Mounted Device (HMD). Oculust Rift and Microsoft Hololens are the most famous HMD devices used in VR. And in 2014, Google Card Board was introduced at Google I/O developers conference. Google Card Board is VR platform which allows user to enjoy the VR with simple and cheap way. In this research, we explore Google Card Board to develop simulation game of raising pet. The Google Card Board is used to create view for the VR environment. The view and control in VR environment is built using Unity game engine. And the simulation process is designed using Finite State Machine (FSM). This FSM can help to design the process clearly. So the simulation process can describe the simulation of raising pet well. Raising pet is fun activity. But sometimes, there are many conditions which cause raising pet become difficult to do, i.e. environment condition, disease, high cost, etc. this research aims to explore and implement Google Card Board in simulation of raising pet.
Powell, R F; Palmer, S M; Palmer, C H; Smith, E B
1977-10-01
A mild dermatitis probably due to Cheyletiella yasguri was observed in 2 persons whose pet dog was infested with this parasite. Cheyletiella mites differ morphologically from sarcoptic mites, which cause canine and human scabies. Treatment of man and dog with 1% gamma benzene hexachloride is usually successful in clearing this condition.
Graham, Taryn M.; Milaney, Katrina J.; Adams, Cindy L.
2018-01-01
Simple Summary In rental housing policy, pets are rarely considered as valued household members. Instead, landlords and property managers are often permitted to ban pets outright, or to advertise them as merely negotiable in their listings for rental housing. In fact, previous research has shown that moving and renting are key reasons for animal relinquishment. To reduce the number of animals that are given up each year due to housing issues, we surveyed landlords and property managers about their perspectives towards pets. Also, because younger adults are disproportionately tenants and because dogs are often banned from rental housing, we interviewed younger tenants with dogs about their recent experiences in the rental market. Our results confirm that dog owners face difficulties in finding rental housing. To keep their pets, tenants made compromises on where and how they lived, which held consequences for their health and that of their pets. Suggestions for improvement are provided, as are implications for research, policy, and practice. Abstract Previous research has shown that housing insecurity contributes to animal relinquishment and that tenants with dogs face disadvantages in the rental market. Still, little is known about how dog owners navigate rental markets, nor how landlords and property managers perceive dogs and other pets. This case study reports on in-depth interviews with younger tenants with dogs and on open-ended survey responses from landlords and property managers. In their housing searches, tenants with dogs reported feeling powerless in negotiations and feeling discriminated against. They described settling for substandard properties, often located in less desirable neighborhoods. Also, some said they felt obliged to stay put in these rentals, given how difficult it had been to find a place that would accommodate their dogs. Meanwhile, landlords and property managers indicated that listings advertised as “pet-friendly” tend to receive more applicants than listings in which pets are prohibited. Suggestions for improvement included meeting pets prior to signing the lease; getting everything in writing; steering clear from furnished units; charging utilities to tenants; and speeding up the pet approval process when dealing with condominium boards. These suggestions offer implications for future research, partnerships, and policy options to improve the prospects of pets and their people in rental housing. PMID:29495477
Human (13)N-ammonia PET studies: the importance of measuring (13)N-ammonia metabolites in blood.
Keiding, Susanne; Sørensen, Michael; Munk, Ole Lajord; Bender, Dirk
2010-03-01
Dynamic (13)N-ammonia PET is used to assess ammonia metabolism in brain, liver and muscle based on kinetic modeling of metabolic pathways, using arterial blood (13)N-ammonia as input function. Rosenspire et al. (1990) introduced a solid phase extraction procedure for fractionation of (13)N-content in blood into (13)N-ammonia, (13)N-urea, (13)N-glutamine and (13)N-glutamate. Due to a radioactive half-life for (13)N of 10 min, the procedure is not suitable for blood samples taken beyond 5-7 min after tracer injection. By modifying Rosenspire's method, we established a method enabling analysis of up to 10 blood samples in the course of 30 min. The modified procedure was validated by HPLC and by 30-min reproducibility studies in humans examined by duplicate (13)N-ammonia injections with a 60-min interval. Blood data from a (13)N-ammonia brain PET study (from Keiding et al. 2006) showed: (1) time courses of (13)N-ammonia fractions could be described adequately by double exponential functions; (2) metabolic conversion of (13)N-ammonia to (13)N-metabolites were in the order: healthy subjects > cirrhotic patients without HE > cirrhotic patients with HE; (3) kinetics of initial tracer distribution in tissue can be assessed by using total (13)N-concentration in blood as input function, whereas assessment of metabolic processes requires (13)N-ammonia measurements.
Li, Hong; Li, Jinyan; Jiang, Jia; Lv, Fang; Chang, Jiang; Chen, Shiyi; Wu, Chengtie
2017-05-01
To solve the poor healing of polyethylene terephthalate (PET) artificial ligament in bone tunnel, copper-containing bioactive glass (Cu-BG) nanocoatings on PET artificial ligaments were successfully prepared by pulsed laser deposition (PLD). It was hypothesized that Cu-BG coated PET (Cu-BG/PET) grafts could enhance the in vitro osteogenic and angiogenic differentiation of rat bone marrow mesenchymal stem cells (rBMSCs) and in vivo graft-bone healing after anterior cruciate ligament (ACL) reconstruction in a goat model. Scanning electron microscope and EDS mapping analysis revealed that the prepared nanocoatings had uniform element distribution (Cu, Ca, Si and P) and nanostructure. The surface hydrophilicity of PET grafts was significantly improved after depositing Cu-BG nanocoatings. The in vitro study displayed that the Cu-BG/PET grafts supported the attachment and proliferation of rBMSCs, and significantly promoted the expression of HIF-1α gene, which up-regulated the osteogenesis-related genes (S100A10, BMP2, OCN) and angiogenesis-related genes (VEGF) in comparison with PET or BG coated PET (BG/PET) grafts which do not contain Cu element. Meanwhile, Cu-BG/PET grafts promoted the bone regeneration at the graft-host bone interface and decreased graft-bone interface width, thus enhancing the bonding strength as well as angiogenesis (as indicated by CD31 expression) in the goat model as compared with BG/PET and pure PET grafts. The study demonstrates that the Cu-containing biomaterials significantly promote osteogenesis and angiogenesis in the repair of bone defects of large animals and thus offering a promising method for ACL reconstruction by using Cu-containing nanobioglass modified PET grafts. It remains a significant challenge to develop an artificial graft with distinct osteogenetic/angiogenetic activity to enhance graft-bone healing for ligament reconstruction. To solve these problems, copper-containing bioactive glass (Cu-BG) nanocoatings on PET artificial ligaments were successfully prepared by pulsed laser deposition (PLD). It was found that the prepared Cu-BG/PET grafts significantly stimulated the proliferation and osteogenic/angiogenic differentiation of bone marrow stromal cells (BMSCs) through activating HIF-1α/S100A10/Ca 2+ signal pathway. The most important is that the in vivo bone-forming ability of Cu-containing biomaterials was, for the first time, elucidated in a large animal model, revealing the enhanced capacity of osteogenesis and angiogenesis with incorporation of bioactive Cu element. It is suggested that the copper-containing biomaterials significantly promote osteogenesis and angiogenesis in large animal defects and thus offering a promising method for ACL reconstruction by using Cu-containing nanobioglass modification of PET grafts, paving the way to apply Cu-containing biomaterials for tissue engineering and regenerative medicine. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Hanaoka, Hirofumi; Tominaga, Hideyuki; Yamada, Keiich; Paudyal, Pramila; Iida, Yasuhiko; Watanabe, Shigeki; Paudyal, Bishnuhari; Higuchi, Tetsuya; Oriuchi, Noboru; Endo, Keigo
2009-08-01
In-111 ((111)In)-labeled octreotide has been clinically used for imaging somatostatin receptor-positive tumors, and radiolabeled octreotide analogs for positron emission tomography (PET) have been developed. Cu-64 ((64)Cu; half-life, 12.7 h) is an attractive radionuclide for PET imaging and is produced with high specific activity using a small biomedical cyclotron. The aim of this study is to produce and fundamentally examine a (64)Cu-labeled octreotide analog, (64)Cu-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-D: -Phe(1)-Tyr(3)-octreotide ((64)Cu-DOTA-TOC). (64)Cu produced using a biomedical cyclotron was reacted with DOTA-TOC for 30 min at 45 degrees C. The stability of (64)Cu-DOTA-TOC was evaluated in vitro (incubated with serum) and in vivo (blood collected after administration) by HPLC analysis. Biodistribution studies were performed in normal mice by administration of mixed solution of (64)Cu-DOTA-TOC and (111)In-DOTA-TOC and somatostatin receptor-positive U87MG tumor-bearing mice by administration of (64)Cu-DOTA-TOC or (64)Cu-1,4,8,11-tetraazacyclotetradecane-1,4,8,11-tetraacetic acid-octreotide ((64)Cu-TETA-OC). The tumor was imaged using (64)Cu-DOTA-TOC, (64)Cu-TETA-OC, and FDG with an animal PET scanner. (64)Cu-DOTA-TOC can be produced in amounts sufficient for clinical study with high radiochemical yield. (64)Cu-DOTA-TOC was stable in vitro, but time-dependent transchelation to protein was observed after injection into mice. In biodistribution studies, the radioactivity of (64)Cu was higher than that of (111)In in all organs except kidney. In tumor-bearing mice, (64)Cu-DOTA-TOC showed a high accumulation in the tumor, and the tumor-to-blood ratio reached as high as 8.81 +/- 1.17 at 6 h after administration. (64)Cu-DOTA-TOC showed significantly higher accumulation in the tumor than (64)Cu-TETA-OC. (64)Cu-DOTA-TOC PET showed a very clear image of the tumor, which was comparable to that of (18)F-FDG PET and very similar to that of (64)Cu-TETA-OC. (64)Cu-DOTA-TOC clearly imaged a somatostatin receptor-positive tumor and seemed to be a potential PET tracer in the clinical phase.
Wong, Wai-Hoi; Li, Hongdi; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio A; Liu, Shitao; Wang, Chao; An, Shaohui
2012-11-01
The dedicated murine PET (MuPET) scanner is a high-resolution, high-sensitivity, and low-cost preclinical PET camera designed and manufactured at our laboratory. In this article, we report its performance according to the NU 4-2008 standards of the National Electrical Manufacturers Association (NEMA). We also report the results of additional phantom and mouse studies. The MuPET scanner, which is integrated with a CT camera, is based on the photomultiplier-quadrant-sharing concept and comprises 180 blocks of 13 × 13 lutetium yttrium oxyorthosilicate crystals (1.24 × 1.4 × 9.5 mm(3)) and 210 low-cost 19-mm photomultipliers. The camera has 78 detector rings, with an 11.6-cm axial field of view and a ring diameter of 16.6 cm. We measured the energy resolution, scatter fraction, sensitivity, spatial resolution, and counting rate performance of the scanner. In addition, we scanned the NEMA image-quality phantom, Micro Deluxe and Ultra-Micro Hot Spot phantoms, and 2 healthy mice. The system average energy resolution was 14% at 511 keV. The average spatial resolution at the center of the field of view was about 1.2 mm, improving to 0.8 mm and remaining below 1.2 mm in the central 6-cm field of view when a resolution-recovery method was used. The absolute sensitivity of the camera was 6.38% for an energy window of 350-650 keV and a coincidence timing window of 3.4 ns. The system scatter fraction was 11.9% for the NEMA mouselike phantom and 28% for the ratlike phantom. The maximum noise-equivalent counting rate was 1,100 at 57 MBq for the mouselike phantom and 352 kcps at 65 MBq for the ratlike phantom. The 1-mm fillable rod was clearly observable using the NEMA image-quality phantom. The images of the Ultra-Micro Hot Spot phantom also showed the 1-mm hot rods. In the mouse studies, both the left and right ventricle walls were clearly observable, as were the Harderian glands. The MuPET camera has excellent resolution, sensitivity, counting rate, and imaging performance. The data show it is a powerful scanner for preclinical animal study and pharmaceutical development.
Cheal, Sarah M.; Yoo, Barney; Boughdad, Sarah; Punzalan, Blesida; Yang, Guangbin; Dilhas, Anna; Torchon, Geralda; Pu, Jun; Axworthy, Don B.; Zanzonico, Pat; Ouerfelli, Ouathek; Larson, Steven M.
2014-01-01
A series of N-acetylgalactosamine-dendrons (NAG-dendrons) and dextrans bearing biotin moieties were compared for their ability to complex with and sequester circulating bispecific anti-tumor antibody (scFv4) streptavidin (SA) fusion protein (scFv4-SA) in vivo, to improve tumor to normal tissue concentration ratios for targeted radioimmunotherapy and diagnosis. Specifically, a total of five NAG-dendrons employing a common synthetic scaffold structure containing 4, 8, 16, or 32 carbohydrate residues and a single biotin moiety were prepared (NAGB), and for comparative purposes, a biotinylated-dextran with average molecular weight (MW) of 500 kD was synthesized from amino-dextran (DEXB). One of the NAGB compounds, CA16, has been investigated in humans; our aim was to determine if other NAGB analogs (e.g. CA8 or CA4) were bioequivalent to CA16 and/or better suited as MST reagents. In vivo studies included dynamic positron-emission tomography (PET) imaging of 124I-labelled-scFv4-SA clearance and dual-label biodistribution studies following multi-step targeting (MST) directed at subcutaneous (s.c.) human colon adenocarcinoma xenografts in mice. The MST protocol consists of three injections: first, a bispecific antibody specific for an anti-tumor associated glycoprotein (TAG-72) single chain genetically-fused with SA (scFv4-SA); second, CA16 or other clearing agent; and third, radiolabeled biotin. We observed using PET imaging of 124I-labelled-scFv4-SA clearance that the spatial arrangement of ligands conjugated to NAG (i.e. biotin) can impact the binding to antibody in circulation and subsequent liver uptake of the NAG-antibody complex. Also, NAGB CA32-LC or CA16-LC can be utilized during MST to achieve comparable tumor- to-blood ratios and absolute tumor uptake seen previously with CA16. Finally, DEXB was equally effective as NAGB CA32-LC at lowering scFv4-SA in circulation, but at the expense of reducing absolute tumor uptake of radiolabeled biotin. PMID:24219178
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Kristina; Lemon, Jennifer A.; Phan, Nghi
There is considerable interest in the health effects associated with low-level radiation exposure from medical imaging procedures. Concerns in the medical community that increased radiation exposure from imaging procedures may increase cancer risk among patients are confounded by research showing that low-dose radiation exposure can extend lifespan by increasing the latency period of some types of cancer. The most commonly used radiopharmaceutical for positron emission tomography (PET) scans is 2-[ 18F] fluoro-2-deoxy-d-glucose ( 18F-FDG), which exposes tissue to a low-dose, mixed radiation quality: 634 keV β+ and 511 keV γ-rays. The goal of this research was to investigate how modificationmore » of cancer risk associated with exposure to low-dose ionising radiation in cancer-prone Trp53+/- mice is influenced by radiation quality from PET. At 7-8 weeks of age, Trp53+/- female mice were exposed to one of five treatments: 0 Gy, 10 mGy γ-rays, 10 mGy 18F-FDG, 4 Gy γ-rays, 10 mGy 18F-FDG + 4 Gy γ-rays (n > 185 per group). The large 4-Gy radiation dose significantly reduced the lifespan by shortening the latency period of cancer and significantly increasing the number of mice with malignancies, compared with unirradiated controls. The 10 mGy γ-rays and 10 mGy PET doses did not significantly modify the frequency or latency period of cancer relative to unirradiated mice. Similarly, the PET scan administered prior to a large 4-Gy dose did not significantly modify the latency or frequency of cancer relative to mice receiving a dose of only 4 Gy. The relative biological effectiveness of radiation quality from 18F-FDG, with respect to malignancy, is approximately 1. Furthermore, when non-cancer endpoints were studied, it was found that the 10-mGy PET group had a significant reduction in kidney lesions (P < 0.021), indicating that a higher absorbed dose (20 ± 0.13 mGy), relative to the whole-body average, which occurs in specific tissues, may not be detrimental.« less
Taylor, Kristina; Lemon, Jennifer A.; Phan, Nghi; ...
2014-05-28
There is considerable interest in the health effects associated with low-level radiation exposure from medical imaging procedures. Concerns in the medical community that increased radiation exposure from imaging procedures may increase cancer risk among patients are confounded by research showing that low-dose radiation exposure can extend lifespan by increasing the latency period of some types of cancer. The most commonly used radiopharmaceutical for positron emission tomography (PET) scans is 2-[ 18F] fluoro-2-deoxy-d-glucose ( 18F-FDG), which exposes tissue to a low-dose, mixed radiation quality: 634 keV β+ and 511 keV γ-rays. The goal of this research was to investigate how modificationmore » of cancer risk associated with exposure to low-dose ionising radiation in cancer-prone Trp53+/- mice is influenced by radiation quality from PET. At 7-8 weeks of age, Trp53+/- female mice were exposed to one of five treatments: 0 Gy, 10 mGy γ-rays, 10 mGy 18F-FDG, 4 Gy γ-rays, 10 mGy 18F-FDG + 4 Gy γ-rays (n > 185 per group). The large 4-Gy radiation dose significantly reduced the lifespan by shortening the latency period of cancer and significantly increasing the number of mice with malignancies, compared with unirradiated controls. The 10 mGy γ-rays and 10 mGy PET doses did not significantly modify the frequency or latency period of cancer relative to unirradiated mice. Similarly, the PET scan administered prior to a large 4-Gy dose did not significantly modify the latency or frequency of cancer relative to mice receiving a dose of only 4 Gy. The relative biological effectiveness of radiation quality from 18F-FDG, with respect to malignancy, is approximately 1. Furthermore, when non-cancer endpoints were studied, it was found that the 10-mGy PET group had a significant reduction in kidney lesions (P < 0.021), indicating that a higher absorbed dose (20 ± 0.13 mGy), relative to the whole-body average, which occurs in specific tissues, may not be detrimental.« less
Jia, Fang; Balaji, Baghavathy S; Gallazzi, Fabio; Lewis, Michael R
2015-11-01
The bcl-2 gene is overexpressed in non-Hodgkin's lymphoma (NHL). We have reported micro-SPECT/CT imaging of Mec-1 human lymphoma xenografts in SCID mice, using [(111)In]DOTA-anti-bcl-2-PNA-Tyr(3)-octreotate. In order to reduce normal organ accumulation and improve imaging contrast, modified monomers with neutral hydrophilic (serine, TS) or negatively charged (aspartic acid, TD) residues were synthesized as substitutes for glycine at T(14) in the PNA sequence. The parent and modified PNA-peptide conjugates were labeled with (64)Cu and evaluated in biodistribution studies and high resolution PET/CT imaging of SCID mice bearing bcl-2-positive Mec-1 xenografts as well as bcl-2-negative Ramos xenografts. Mice were administered the (64)Cu-labeled conjugates for biodistribution and imaging studies. Biodistributions were obtained from 1 to 48 h post-injection. Mice were imaged from 1 to 48 h post-injection. The parent glycine conjugate and two modified conjugates all showed selective tumor uptake in Mec-1 xenografts. The liver uptake of the serine conjugate was significantly reduced compared to the two other PNA conjugates. Its kidney uptake was highest of the three at 47.1% ID/g at 1h and dropped to 20.6% ID/g at 24h. [Copper-64]DOTA-anti-bcl-2-TS-PNA-Tyr(3)-octreotate showed tumor uptake of 1.38% ID/g at 1h and 1.06% ID/g at 24h. The tumor-to-blood ratio was increased by factor of 2 from 1h to 24h. This compound detected Mec-1 tumors by micro-PET/CT as early as 1h post-injection and at time points out to 48 h. However, the negative control Ramos tumor could not be detected. These (64)Cu-labeled, amino acid-modified PNA conjugates showed selective tumor targeting in vivo, and tumor xenografts were detected by micro-PET/CT as early as 1h post-injection, suggesting that bcl-2 expression at the mRNA level can detected by PET in mouse models of NHL. Advances in knowledge and implications for patient care Down-regulating bcl-2, an anti-apoptotic proto-oncogene, is a mechanism to reverse chemotherapy resistance in humans with NHL. Thus, bcl-2 overexpression might be considered a new independent prognostic parameter in NHL, aiding in the identification of patients at risk for treatment failure. We have developed [(64)Cu]DOTA-anti-bcl-2-PNA-Tyr(3)-octreotate conjugates for targeted antisense PET imaging. Our preclinical studies identified an effective combination of antisense and radionuclide imaging, with the goal of future clinical trials in patients. This imaging modality may improve clinical care by identifying patients who might respond better to conventional chemotherapy. Copyright © 2015. Published by Elsevier Inc.
Abualhaj, Bedor; Weng, Guoyang; Ong, Melissa; Attarwala, Ali Asgar; Molina, Flavia; Büsing, Karen; Glatting, Gerhard
2017-01-01
Dynamic [ 18 F]fluoro-ethyl-L-tyrosine positron emission tomography ([ 18 F]FET-PET) is used to identify tumor lesions for radiotherapy treatment planning, to differentiate glioma recurrence from radiation necrosis and to classify gliomas grading. To segment different regions in the brain k-means cluster analysis can be used. The main disadvantage of k-means is that the number of clusters must be pre-defined. In this study, we therefore compared different cluster validity indices for automated and reproducible determination of the optimal number of clusters based on the dynamic PET data. The k-means algorithm was applied to dynamic [ 18 F]FET-PET images of 8 patients. Akaike information criterion (AIC), WB, I, modified Dunn's and Silhouette indices were compared on their ability to determine the optimal number of clusters based on requirements for an adequate cluster validity index. To check the reproducibility of k-means, the coefficients of variation CVs of the objective function values OFVs (sum of squared Euclidean distances within each cluster) were calculated using 100 random centroid initialization replications RCI 100 for 2 to 50 clusters. k-means was performed independently on three neighboring slices containing tumor for each patient to investigate the stability of the optimal number of clusters within them. To check the independence of the validity indices on the number of voxels, cluster analysis was applied after duplication of a slice selected from each patient. CVs of index values were calculated at the optimal number of clusters using RCI 100 to investigate the reproducibility of the validity indices. To check if the indices have a single extremum, visual inspection was performed on the replication with minimum OFV from RCI 100 . The maximum CV of OFVs was 2.7 × 10 -2 from all patients. The optimal number of clusters given by modified Dunn's and Silhouette indices was 2 or 3 leading to a very poor segmentation. WB and I indices suggested in median 5, [range 4-6] and 4, [range 3-6] clusters, respectively. For WB, I, modified Dunn's and Silhouette validity indices the suggested optimal number of clusters was not affected by the number of the voxels. The maximum coefficient of variation of WB, I, modified Dunn's, and Silhouette validity indices were 3 × 10 -2 , 1, 2 × 10 -1 and 3 × 10 -3 , respectively. WB-index showed a single global maximum, whereas the other indices showed also local extrema. From the investigated cluster validity indices, the WB-index is best suited for automated determination of the optimal number of clusters for [ 18 F]FET-PET brain images for the investigated image reconstruction algorithm and the used scanner: it yields meaningful results allowing better differentiation of tissues with higher number of clusters, it is simple, reproducible and has an unique global minimum. © 2016 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Li, Mengmeng; Wang, Shiwen; Jiang, Jia; Sun, Jiashu; Li, Yuzhuo; Huang, Deyong; Long, Yun-Ze; Zheng, Wenfu; Chen, Shiyi; Jiang, Xingyu
2015-04-01
The Ligament Advanced Reinforcement System (LARS) has been considered as a promising graft for ligament reconstruction. To improve its biocompatibility and effectiveness on new bone formation, we modified the surface of a polyethylene terephthalate (PET) ligament with nanoscale silica using atom transfer radical polymerization (ATRP) and silica polymerization. The modified ligament is tested by both in vitro and in vivo experiments. Human osteoblast testing in vitro exhibits an ~21% higher value in cell viability for silica-modified grafts compared with original grafts. Animal testing in vivo shows that there is new formed bone in the case of a nanoscale silica-coated ligament. These results demonstrate that our approach for nanoscale silica surface modification on LARS could be potentially applied for ligament reconstruction.The Ligament Advanced Reinforcement System (LARS) has been considered as a promising graft for ligament reconstruction. To improve its biocompatibility and effectiveness on new bone formation, we modified the surface of a polyethylene terephthalate (PET) ligament with nanoscale silica using atom transfer radical polymerization (ATRP) and silica polymerization. The modified ligament is tested by both in vitro and in vivo experiments. Human osteoblast testing in vitro exhibits an ~21% higher value in cell viability for silica-modified grafts compared with original grafts. Animal testing in vivo shows that there is new formed bone in the case of a nanoscale silica-coated ligament. These results demonstrate that our approach for nanoscale silica surface modification on LARS could be potentially applied for ligament reconstruction. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr01439e
The effect of respiratory induced density variations on non-TOF PET quantitation in the lung.
Holman, Beverley F; Cuplov, Vesna; Hutton, Brian F; Groves, Ashley M; Thielemans, Kris
2016-04-21
Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant (18)F-FDG and (18)F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung.
The effect of respiratory induced density variations on non-TOF PET quantitation in the lung
NASA Astrophysics Data System (ADS)
Holman, Beverley F.; Cuplov, Vesna; Hutton, Brian F.; Groves, Ashley M.; Thielemans, Kris
2016-04-01
Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant 18F-FDG and 18F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung.
Cortés Romera, M; Gámez Cenzano, C; Caresia Aróztegui, A P; Martín-Comín, J; González-Barca, E; Ricart Brulles, Y; Palacios Abufón, A; Robles Barba, J; Rodríguez-Bel, L; Rossi Seoane, S; Fernández de Sevilla, A
2012-01-01
To assess the role of FDG-PET/CT performed after the first cycles of chemotherapy in the prediction of response to treatment in patients with diffuse large B-cell lymphoma. Twenty patients (mean age: 48 years) were included, 16 initial staging and 4 relapse. All patients underwent PET/CT at 3 times: 1) Baseline, 2) After 1-3 cycles of chemotherapy (early response assessment), and 3) End of treatment (evaluation of final response). Early PET/CT findings were correlated to the end-treatment PET/CT and follow-up. The evaluation of the response was established according to the decrease in uptake of the lesions (SUVmax). In the early assessment, a good response indicator (GRI) was obtained when the lesion disappeared or had more than 50% reduction in SUVmax. At the end of the treatment, a complete metabolic response (CMR) was determined in negative PET scans. Follow-up was superior to 19 months and final outcome was established as progression/relapse or no evidence of disease (NED). At the early treatment evaluation, 16/16 patients of initial staging (100%) and 2/4 of relapse (50%) achieved GRI. At the end of treatment evaluation, 14/16 patients of initial staging with GRI achieved CMR and 1/16 PMR: 14 were alive with NED in the follow-up while 1 relapsed. In the second group, 2/2 patients with GRI achieved CMR (100%): 1 continued with NED in the follow-up and another relapsed. FDG-PET/CT after the first cycles of chemotherapy is useful to monitor treatment due to its high negative predictive value (87.5%), using it to modify treatment early in the non-responders. Copyright © 2011 Elsevier España, S.L. y SEMNIM. All rights reserved.
NASA Astrophysics Data System (ADS)
Qian, Zhengmin (Min); Dong, Guang-Hui; Ren, Wan-Hui; Simckes, Maayan; Wang, Jing; Zelicoff, Alan; Trevathan, Edwin
2014-04-01
Previous studies examining pet ownership as a risk factor for respiratory conditions have yielded inconsistent results. Little is known about whether or not pet ownership modifies the relationship between air pollutants and respiratory symptoms and asthma in children. In order to evaluate the interaction between pet and air pollution on respiratory health in children, we recruited 30,149 children, aged 2-12 years, from 25 districts of seven cities in northeast China. Parents of the children completed questionnaires that characterized the children's histories of respiratory symptoms and illnesses and associated risk factors. Average ambient annual exposures to particulate matter with an aerodynamic diameter ≤10 μm (PM10), sulfur dioxide (SO2), nitrogen dioxide (NO2), and ozone (O3) were estimated from monitoring stations in each of the 25 study districts. The results showed that among children without pets at home, there were statistically significant associations between both recent exacerbations of asthma among physician-diagnosed asthmatics and respiratory symptoms and all pollutants examined. Odds ratios (ORs) ranged from 1.12 [95% confidence interval (CI), 1.00-1.26] to 1.41 (95% CI, 1.24-1.61) per 31 μg m-3 for PM10, whereas, among children with pets at home, there were no effects or small effects for either asthma or the symptoms. The interactions between dog ownership and PM10, SO2, NO2, and O3 were statistically significant, such that children with a dog at home had lower reporting of both current asthma and current wheeze. In conclusion, this study suggests that pet ownership decreased the effects of air pollution on respiratory symptoms and asthma among Chinese children.
Biases in Multicenter Longitudinal PET Standardized Uptake Value Measurements1
Doot, Robert K; Pierce, Larry A; Byrd, Darrin; Elston, Brian; Allberg, Keith C; Kinahan, Paul E
2014-01-01
This study investigates measurement biases in longitudinal positron-emission tomography/computed tomography (PET/CT) studies that are due to instrumentation variability including human error. Improved estimation of variability between patient scans is of particular importance for assessing response to therapy and multicenter trials. We used National Institute of Standards and Technology-traceable calibration methodology for solid germanium-68/gallium-68 (68Ge/68Ga) sources used as surrogates for fluorine-18 (18F) in radionuclide activity calibrators. One cross-calibration kit was constructed for both dose calibrators and PET scanners using the same 9-month half-life batch of 68Ge/68Ga in epoxy. Repeat measurements occurred in a local network of PET imaging sites to assess standardized uptake value (SUV) errors over time for six dose calibrators from two major manufacturers and for six PET/CT scanners from three major manufacturers. Bias in activity measures by dose calibrators ranged from -50% to 9% and was relatively stable over time except at one site that modified settings between measurements. Bias in activity concentration measures by PET scanners ranged from -27% to 13% with a median of 174 days between the six repeat scans (range, 29 to 226 days). Corresponding errors in SUV measurements ranged from -20% to 47%. SUV biases were not stable over time with longitudinal differences for individual scanners ranging from -11% to 59%. Bias in SUV measurements varied over time and between scanner sites. These results suggest that attention should be paid to PET scanner calibration for longitudinal studies and use of dose calibrator and scanner cross-calibration kits could be helpful for quality assurance and control. PMID:24772207
Rakheja, Rajan; Chandarana, Hersh; DeMello, Linda; Jackson, Kimberly; Geppert, Christian; Faul, David; Glielmi, Christopher; Friedman, Kent P
2013-11-01
The purpose of this study was to assess the correlation between standardized uptake value (SUV) and apparent diffusion coefficient (ADC) of neoplastic lesions in the use of a simultaneous PET/MRI hybrid system. Twenty-four patients with known primary malignancies underwent FDG PET/CT. They then underwent whole-body PET/MRI. Diffusion-weighted imaging was performed with free breathing and a single-shot spin-echo echo-planar imaging sequence with b values of 0, 350, and 750 s/mm(2). Regions of interest were manually drawn along the contours of neoplastic lesions larger than 1 cm, which were clearly identified on PET and diffusion-weighted images. Maximum SUV (SUVmax) on PET/MRI and PET/CT images, mean SUV (SUVmean), minimum ADC (ADCmin), and mean ADC (ADCmean) were recorded on PET/MR images for each FDG-avid neoplastic soft-tissue lesion with a maximum of three lesions per patient. Pearson correlation coefficient was used to asses the following relations: SUVmax versus ADCmin on PET/MR and PET/CT images, SUVmean versus ADCmean, and ratio of SUVmax to mean liver SUV (SUV ratio) versus ADCmin. A subanalysis of patients with progressive disease versus partial treatment response was performed with the ratio of SUVmax to ADCmin for the most metabolically active lesion. Sixty-nine neoplastic lesions (52 nonosseous lesions, 17 bone metastatic lesions) were evaluated. The mean SUVmax from PET/MRI was 7.0 ± 6.0; SUVmean, 5.6 ± 4.6; mean ADCmin, 1.10 ± 0.58; and mean ADCmean, 1.48 ± 0.72. A significant inverse Pearson correlation coefficient was found between PET/MRI SUVmax and ADCmin (r = -0.21, p = 0.04), between SUVmean and ADCmean (r = -0.18, p = 0.07), and between SUV ratio and ADCmin (r = -0.27, p = 0.01). A similar inverse Pearson correlation coefficient was found between the PET/CT SUVmax and ADCmin. Twenty of 24 patients had previously undergone PET/CT; five patients had a partial treatment response, and six had progressive disease according to Response Evaluation Criteria in Solid Tumors 1.1. The ratio between SUVmax and ADCmin was higher among patients with progressive disease than those with a partial treatment response. Simultaneous PET/MRI is a promising technology for the detection of neoplastic disease. There are inverse correlations between SUVmax and ADCmin and between SUV ratio and ADCmin. Correlation coefficients between SUVmax and ADCmin from PET/MRI were similar to values obtained with SUVmax from the same-day PET/CT. Given that both SUV and ADC are related to malignancy and that the correlation between the two biomarkers is relatively weak, SUV and ADC values may offer complementary information to aid in determination of prognosis and treatment response. The combined tumoral biomarker, ratio between SUVmax and ADCmin, may be useful for assessing progressive disease versus partial treatment response.
Significance of the impact of motion compensation on the variability of PET image features
NASA Astrophysics Data System (ADS)
Carles, M.; Bach, T.; Torres-Espallardo, I.; Baltas, D.; Nestle, U.; Martí-Bonmatí, L.
2018-03-01
In lung cancer, quantification by positron emission tomography/computed tomography (PET/CT) imaging presents challenges due to respiratory movement. Our primary aim was to study the impact of motion compensation implied by retrospectively gated (4D)-PET/CT on the variability of PET quantitative parameters. Its significance was evaluated by comparison with the variability due to (i) the voxel size in image reconstruction and (ii) the voxel size in image post-resampling. The method employed for feature extraction was chosen based on the analysis of (i) the effect of discretization of the standardized uptake value (SUV) on complementarity between texture features (TF) and conventional indices, (ii) the impact of the segmentation method on the variability of image features, and (iii) the variability of image features across the time-frame of 4D-PET. Thirty-one PET-features were involved. Three SUV discretization methods were applied: a constant width (SUV resolution) of the resampling bin (method RW), a constant number of bins (method RN) and RN on the image obtained after histogram equalization (method EqRN). The segmentation approaches evaluated were 40% of SUVmax and the contrast oriented algorithm (COA). Parameters derived from 4D-PET images were compared with values derived from the PET image obtained for (i) the static protocol used in our clinical routine (3D) and (ii) the 3D image post-resampled to the voxel size of the 4D image and PET image derived after modifying the reconstruction of the 3D image to comprise the voxel size of the 4D image. Results showed that TF complementarity with conventional indices was sensitive to the SUV discretization method. In the comparison of COA and 40% contours, despite the values not being interchangeable, all image features showed strong linear correlations (r > 0.91, p\\ll 0.001 ). Across the time-frames of 4D-PET, all image features followed a normal distribution in most patients. For our patient cohort, the compensation of tumor motion did not have a significant impact on the quantitative PET parameters. The variability of PET parameters due to voxel size in image reconstruction was more significant than variability due to voxel size in image post-resampling. In conclusion, most of the parameters (apart from the contrast of neighborhood matrix) were robust to the motion compensation implied by 4D-PET/CT. The impact on parameter variability due to the voxel size in image reconstruction and in image post-resampling could not be assumed to be equivalent.
16 CFR 260.10 - Non-toxic claims.
Code of Federal Regulations, 2013 CFR
2013-01-01
... pose any risk to humans or the environment, including household pets. If the cleaning product poses no... implication, that a product, package, or service is non-toxic. Non-toxic claims should be clearly and... product, package, or service is non-toxic both for humans and for the environment generally. Therefore...
16 CFR 260.10 - Non-toxic claims.
Code of Federal Regulations, 2014 CFR
2014-01-01
... pose any risk to humans or the environment, including household pets. If the cleaning product poses no... implication, that a product, package, or service is non-toxic. Non-toxic claims should be clearly and... product, package, or service is non-toxic both for humans and for the environment generally. Therefore...
Knowledge and Technology: Sharing With Society
NASA Astrophysics Data System (ADS)
Benvenuti, Cristoforo; Sutton, Christine; Wenninger, Horst
The following sections are included: * A Core Mission of CERN * Medical Accelerators: A Tool for Tumour Therapy * Medipix: The Image is the Message * Crystal Clear: From Higgs to PET * Solar Collectors: When Nothing is Better * The TARC Experiment at CERN: Modern Alchemy * A CLOUD Chamber with a Silvery Lining * References
Evaluation of positron-emission-tomography for visualisation of migration processes in geomaterials
NASA Astrophysics Data System (ADS)
Kulenkampff, J.; Gründig, M.; Richter, M.; Enzmann, F.
Positron-emission-tomography (PET) was applied for direct visualisation of solute transport in order to overcome the limitations of conventional methods for measuring advection and diffusion properties. At intervals from minutes to days the 3D-spatial distribution of the PET-tracer is determined. This spatiotemporal evolution of the tracer concentration can be used as experimental basis for clarification of the relevant transport processes, derivation of transport parameters, and model calibration. Here, 18F and 124I in 0.01 M carrier solution of KF and KI, respectively, have been chosen out of the limited number of available PET-tracers, primarily on account of their decay time and the time span of the experiments. The sample is a granite core from the Äspö Hard Rock Laboratory which carries an axial fracture with an aperture of ∼0.5 mm. Therefore, its permeability is high: high injection rates of 0.1 ml/min caused a pressure drop below 100 kPa. The experiments showed that the transport path through the fracture is modulated by the flow rate. The comparison of the experiments with different flow rates indicates diffusion into the matrix material at localized sites. However, the derived diffusion length falls below the resolution limits of the medical PET-scanner. With recently available dedicated high-resolution PET-scanners, which are usually applied in biomedical research, diffusion effects will be clearly resolvable.
Development of 89Zr-Ontuxizumab for in vivo TEM-1/endosialin PET applications
Lange, Sara E.S.; Zheleznyak, Alex; Studer, Matthew; O'Shannessy, Daniel J.; Lapi, Suzanne E.; Van Tine, Brian A.
2016-01-01
Purpose The complexity of sarcoma has led to the need for patient selection via in vivo biomarkers. Tumor endothelial marker-1 (TEM-1) is a cell surface marker expressed by the tumor microenvironment. Currently MORAb-004 (Ontuxizumab), an anti-TEM-1 humanized monoclonal antibody, is in sarcoma clinical trials. Development of positron emission tomography (PET) for in vivo TEM-1 expression may allow for stratification of patients, potentially enhancing clinical outcomes seen with Ontuxizumab. Results Characterization of cell lines revealed clear differences in TEM-1 expression. One high expressing (RD-ES) and one low expressing (LUPI) cell line were xenografted, and mice were injected with 89Zr-Ontuxizumab. PET imaging post-injection revealed that TEM-1 was highly expressed and readily detectable in vivo only in RD-ES. In vivo biodistribution studies confirmed high radiopharmaceutical uptake in tumor relative to normal organs. Experimental Design Sarcoma cell lines were characterized for TEM-1 expression. Ontuxizumab was labeled with 89Zr and evaluated for immunoreactivity preservation. 89Zr-Ontuxizumab was injected into mice with high or null expressing TEM-1 xenografts. In vivo PET imaging experiments were performed. Conclusion 89Zr-Ontuxizumab can be used in vivo to determine high versus low TEM-1 expression. Reliable PET imaging of TEM-1 in sarcoma patients may allow for identification of patients that will attain the greatest benefit from anti-TEM-1 therapy. PMID:26909615
Guinchard, A-C; Ghazaleh, Naghmeh; Saenz, M; Fornari, E; Prior, J O; Maeder, P; Adib, S; Maire, R
2016-11-01
We studied possible brain changes with functional MRI (fMRI) and fluorodeoxyglucose positron emission tomography (FDG-PET) in a patient with a rare, high-intensity "objective tinnitus" (high-level SOAEs) in the left ear of 10 years duration, with no associated hearing loss. This is the first case of objective cochlear tinnitus to be investigated with functional neuroimaging. The objective cochlear tinnitus was measured by Spontaneous Otoacoustic Emissions (SOAE) equipment (frequency 9689 Hz, intensity 57 dB SPL) and is clearly audible to anyone standing near the patient. Functional modifications in primary auditory areas and other brain regions were evaluated using 3T and 7T fMRI and FDG-PET. In the fMRI evaluations, a saturation of the auditory cortex at the tinnitus frequency was observed, but the global cortical tonotopic organization remained intact when compared to the results of fMRI of healthy subjects. The FDG-PET showed no evidence of an increase or decrease of activity in the auditory cortices or in the limbic system as compared to normal subjects. In this patient with high-intensity objective cochlear tinnitus, fMRI and FDG-PET showed no significant brain reorganization in auditory areas and/or in the limbic system, as reported in the literature in patients with chronic subjective tinnitus. Copyright © 2016 Elsevier B.V. All rights reserved.
Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.
2014-01-01
Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections. 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) scanning has been suggested as an alternative for the diagnosis and assessment of infectious processes. Hybrid 18F-FDG PET/CT has established the role of 18F-FDG PET for the assessment of suspected VPGI, providing accurate anatomic localization of the site of infection. However, there are no clear guidelines for the interpretation of the uptake patterns of 18F-FDG as clinical tool for VPGI. Based on the available literature it is suggested that a linear, diffuse, and homogeneous uptake should not be regarded as an infection whereas focal or heterogeneous uptake with a projection over the vessel on CT is highly suggestive of infection. Nevertheless, 18F-FDG PET and 18F-FDG PET/CT can play an important role in the detection of VPGI and monitoring response to treatment. However an accurate uptake and pattern recognition is warranted and cut-off uptake values and patterns need to be standardized before considering the technique to be the new standard. PMID:25210712
Warnock, Geoff; Turtoi, Andrei; Blomme, Arnaud; Bretin, Florian; Bahri, Mohamed Ali; Lemaire, Christian; Libert, Lionel Cyrille; Seret, Alain E J J; Luxen, André; Castronovo, Vincenzo; Plenevaux, Alain R E G
2013-10-01
For many years the laboratory mouse has been used as the standard model for in vivo oncology research, particularly in the development of novel PET tracers, but the growth of tumors on chicken chorioallantoic membrane (CAM) provides a more rapid, low cost, and ethically sustainable alternative. For the first time, to our knowledge, we demonstrate the feasibility of in vivo PET and CT imaging in a U87 glioblastoma tumor model on chicken CAM, with the aim of applying this model for screening of novel PET tracers. U87 glioblastoma cells were implanted on the CAM at day 11 after fertilization and imaged at day 18. A small-animal imaging cell was used to maintain incubation and allow anesthesia using isoflurane. Radiotracers were injected directly into the exposed CAM vasculature. Sodium (18)F-fluoride was used to validate the imaging protocol, demonstrating that image-degrading motion can be removed with anesthesia. Tumor glucose metabolism was imaged using (18)F-FDG, and tumor protein synthesis was imaged using 2-(18)F-fluoro-l-tyrosine. Anatomic images were obtained by contrast-enhanced CT, facilitating clear delineation of the tumor, delineation of tracer uptake in tumor versus embryo, and accurate volume measurements. PET imaging of tumor glucose metabolism and protein synthesis was successfully demonstrated in the CAM U87 glioblastoma model. Catheterization of CAM blood vessels facilitated dynamic imaging of glucose metabolism with (18)F-FDG and demonstrated the ability to study PET tracer uptake over time in individual tumors, and CT imaging improved the accuracy of tumor volume measurements. We describe the novel application of PET/CT in the CAM tumor model, with optimization of typical imaging protocols. PET imaging in this valuable tumor model could prove particularly useful for rapid, high-throughput screening of novel radiotracers.
Real-time iterative monitoring of radiofrequency ablation tumor therapy with 15O-water PET imaging.
Bao, Ande; Goins, Beth; Dodd, Gerald D; Soundararajan, Anuradha; Santoyo, Cristina; Otto, Randal A; Davis, Michael D; Phillips, William T
2008-10-01
A method that provides real-time image-based monitoring of solid tumor therapy to ensure complete tumor eradication during image-guided interventional therapy would be a valuable tool. The short, 2-min half-life of (15)O makes it possible to perform repeated PET imaging at 20-min intervals at multiple time points before and after image-guided therapy. In this study, (15)O-water PET was evaluated as a tool to provide real-time feedback and iterative image guidance to rapidly monitor the intratumoral coverage of radiofrequency (RF) ablation therapy. Tumor RF ablation therapy was performed on head and neck squamous cell carcinoma (SCC) xenograft tumors (length, approximately 23 mm) in 6 nude rats. The tumor in each animal was ablated with RF (1-cm active size ablation catheter, 70 degrees C for 5 min) twice in 2 separate tumor regions with a 20-min separation. The (15)O-water PET images were acquired before RF ablation and after the first RF and second RF ablations using a small-animal PET scanner. In each PET session, approximately 100 MBq of (15)O-water in 1.0 mL of saline were injected intravenously into each animal. List-mode PET images were acquired for 7 min starting 20 s before injection. PET images were reconstructed by 2-dimensional ordered-subset expectation maximization into single-frame images and dynamic images at 10 s/frame. PET images were displayed and analyzed with software. Pre-RF ablation images demonstrate that (15)O-water accumulates in tumors with (15)O activity reaching peak levels immediately after administration. After RF ablation, the ablated region had almost zero activity, whereas the unablated tumor tissue continued to have a high (15)O-water accumulation. Using image feedback, the RF probe was repositioned to a tumor region with residual (15)O-water uptake and then ablated. The second RF ablation in this new region of the tumor resulted in additional ablation of the solid tumor, with a corresponding decrease in activity on the (15)O-water PET image. (15)O-water PET clearly demonstrated the ablated tumor region, whereas the unablated tumor continued to show high (15)O-water accumulation. (15)O-water imaging shows promise as a tool for on-site, real-time monitoring of image-guided interventional cancer therapy.
Clinical applications with the HIDAC positron camera
NASA Astrophysics Data System (ADS)
Frey, P.; Schaller, G.; Christin, A.; Townsend, D.; Tochon-Danguy, H.; Wensveen, M.; Donath, A.
1988-06-01
A high density avalanche chamber (HIDAC) positron camera has been used for positron emission tomographic (PET) imaging in three different human studies, including patients presenting with: (I) thyroid diseases (124 cases); (II) clinically suspected malignant tumours of the pharynx or larynx (ENT) region (23 cases); and (III) clinically suspected primary malignant and metastatic tumours of the liver (9 cases, 19 PET scans). The positron emitting radiopharmaceuticals used for the three studies were Na 124I (4.2 d half-life) for the thyroid, 55Co-bleomycin (17.5 h half-life) for the ENT-region and 68Ga-colloid (68 min half-life) for the liver. Tomographic imaging was performed: (I) 24 h after oral Na 124I administration to the thyroid patients, (II) 18 h after intraveneous administration of 55Co-bleomycin to the ENT patients and (III) 20 min following the intraveneous injection of 68Ga-colloid to the liver tumour patients. Three different imaging protocols were used with the HIDAC positron camera to perform appropriate tomographic imaging in each patient study. Promising results were obtained in all three studies, particularly in tomographic thyroid imaging, where a significant clinical contribution is made possible for diagnosis and therapy planning by the PET technique. In the other two PET studies encouraging results were obtained for the detection and precise localisation of malignant tumour disease including an estimate of the functional liver volume based on the reticulo-endothelial-system (RES) of the liver, obtained in vivo, and the three-dimensional display of liver PET data using shaded graphics techniques. The clinical significance of the overall results obtained in both the ENT and the liver PET study, however, is still uncertain and the respective role of PET as a new imaging modality in these applications is not yet clearly established. To appreciate the clinical impact made by PET in liver and ENT malignant tumour staging needs further investigation, and more detailed data on a larger number of clinical and experimental PET scans will be necessary for definitive evaluation. Nevertheless, the HIDAC positron camera may be used for clinical PET imaging in well-defined patient cases, particularly in situations where both high spatial resolution is desired in the reconstructed image of the examined pathological condition and at the same time "static" PET imaging may be adequate, as is the case in thyroid-, ENT- and liver tomographic imaging using the HIDAC positron camera.
MEG Frequency Analysis Depicts the Impaired Neurophysiological Condition of Ischemic Brain
Ikeda, Hidetoshi; Tsuyuguchi, Naohiro; Uda, Takehiro; Okumura, Eiichi; Asakawa, Takashi; Haruta, Yasuhiro; Nishiyama, Hideki; Okada, Toyoji; Kamada, Hajime; Ohata, Kenji; Miki, Yukio
2016-01-01
Purpose Quantitative imaging of neuromagnetic fields based on automated region of interest (ROI) setting was analyzed to determine the characteristics of cerebral neural activity in ischemic areas. Methods Magnetoencephalography (MEG) was used to evaluate spontaneous neuromagnetic fields in the ischemic areas of 37 patients with unilateral internal carotid artery (ICA) occlusive disease. Voxel-based time-averaged intensity of slow waves was obtained in two frequency bands (0.3–4 Hz and 4–8 Hz) using standardized low-resolution brain electromagnetic tomography (sLORETA) modified for a quantifiable method (sLORETA-qm). ROIs were automatically applied to the anterior cerebral artery (ACA), anterior middle cerebral artery (MCAa), posterior middle cerebral artery (MCAp), and posterior cerebral artery (PCA) using statistical parametric mapping (SPM). Positron emission tomography with 15O-gas inhalation (15O-PET) was also performed to evaluate cerebral blood flow (CBF) and oxygen extraction fraction (OEF). Statistical analyses were performed using laterality index of MEG and 15O-PET in each ROI with respect to distribution and intensity. Results MEG revealed statistically significant laterality in affected MCA regions, including 4–8 Hz waves in MCAa, and 0.3–4 Hz and 4–8 Hz waves in MCAp (95% confidence interval: 0.020–0.190, 0.030–0.207, and 0.034–0.213), respectively. We found that 0.3–4 Hz waves in MCAp were highly correlated with CBF in MCAa and MCAp (r = 0.74, r = 0.68, respectively), whereas 4–8 Hz waves were moderately correlated with CBF in both the MCAa and MCAp (r = 0.60, r = 0.63, respectively). We also found that 4–8 Hz waves in MCAp were statistically significant for misery perfusion identified on 15O-PET (p<0.05). Conclusions Quantitatively imaged spontaneous neuromagnetic fields using the automated ROI setting enabled clear depiction of cerebral ischemic areas. Frequency analysis may reveal unique neural activity that is distributed in the impaired vascular metabolic territory, in which the cerebral infarction has not yet been completed. PMID:27992543
Associations of pet ownership with biomarkers of ageing: population based cohort study.
Batty, G David; Zaninotto, Paola; Watt, Richard G; Bell, Steven
2017-12-13
To examine the prospective relation between animal companionship and biomarkers of ageing in older people. Analyses of data from the English Longitudinal Study of Ageing, an ongoing, open, prospective cohort study initiated in 2002-03. Nationally representative study from England. 8785 adults (55% women) with a mean age of 67 years (SD 9) at pet ownership assessment in 2010-11 (wave 5). Established biomarkers of ageing in the domains of physical, immunological, and psychological function, as assessed in 2012-13 (wave 6). One third of study members reported pet ownership: 1619 (18%) owned a dog, 1077 (12%) a cat, and 274 (3%) another animal. After adjustment for a range of covariates, there was no evidence of a clear association of any type of pet ownership with walking speed, lung function, chair rise time, grip strength, leg raises, balance, three markers of systemic inflammation, memory, or depressive symptoms. In this population of older adults, the companionship of creatures great and small seems to essentially confer no relation with standard ageing phenotypes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
2018-01-01
The combination of early diagnosis and complete surgical resection offers the greatest prospect of curative cancer treatment. An iodine-124/fluorescein-based dual-modality labeling reagent, 124I-Green, constitutes a generic tool for one-step installation of a positron emission tomography (PET) and a fluorescent reporter to any cancer-specific antibody. The resulting antibody conjugate would allow both cancer PET imaging and intraoperative fluorescence-guided surgery. 124I-Green was synthesized in excellent radiochemical yields of 92 ± 5% (n = 4) determined by HPLC with an improved one-pot three-component radioiodination reaction. The A5B7 carcinoembryonic antigen (CEA)-specific antibody was conjugated to 124I-Green. High tumor uptake of the dual-labeled A5B7 of 20.21 ± 2.70, 13.31 ± 0.73, and 10.64 ± 1.86%ID/g was observed in CEA-expressing SW1222 xenograft mouse model (n = 3) at 24, 48, and 72 h post intravenous injection, respectively. The xenografts were clearly visualized by both PET/CT and ex vivo fluorescence imaging. These encouraging results warrant the further translational development of 124I-Green for cancer PET imaging and fluorescence-guided surgery. PMID:29388770
Association between exposure to farm animals and pets and risk of Multiple Sclerosis.
Siejka, Dylan; Taylor, Bruce; Ponsonby, Anne-Louise; Dwyer, Terence; van der Mei, Ingrid
2016-11-01
There exists inconsistent evidence regarding animals including pets as risk factors for the development of Multiple Sclerosis (MS). We investigated the association between farm animals and pets as possible environmental factors in MS development. Population based case-control study with 136 clinically definite MS cases and 272 controls randomly chosen from the community matched on sex and age. Data was collected from both questionnaire and a lifetime calendar detailing residence, occupation and pet/animal exposure over the course of participant's lives. Exposure to farming, livestock, specific farm animals and remoteness of residence showed no significant association with MS risk. Exposure to cats prior to disease onset was associated with a greater risk of MS (Adjusted Odds Ratio 2.46 (1.17-5.18)) but without a clear dose-response (test for trend, p=0.76). In contrast to other literature, farming and exposure to farm animals were not associated with MS. While we identified an association between cat exposure and MS, there was no dose-response relationship, and previous studies showed inconsistent results, leaving us to conclude that there is no strong evidence that exposure to cats is associated with MS. Copyright © 2016 Elsevier B.V. All rights reserved.
Hayasaka, Daisuke; Nishi, Kodai; Fuchigami, Takeshi; Shiogama, Kazuya; Onouchi, Takanori; Shimada, Satoshi; Tsutsumi, Yutaka; Morita, Kouichi
2016-01-05
Severe fever with thrombocytopenia syndrome (SFTS) is an emerging disease that causes fever, enteritis, thrombocytopenia, and leucopenia and can be fatal in up to 30% of cases. However, the mechanism of severe disease is not fully understood. Molecular imaging approaches, such as positron-emission tomography (PET), are functional in vivo imaging techniques that provide real-time dynamics of disease progression, assessments of pharmacokinetics, and diagnoses for disease progression. Molecular imaging also potentially provides useful approaches to explore the pathogenesis of viral infections. Thus, the purpose of this study was to image the pathological features of SFTSV infection in vivo by PET imaging. In a mouse model, we showed that 18F-FDG accumulations clearly identified the intestinal tract site as a pathological site. We also demonstrated that 18F-FDG PET imaging can assess disease progression and response to antiserum therapy within the same individual. This is the first report demonstrating a molecular imaging strategy for SFTSV infection. Our results provide potentially useful information for preclinical studies such as the elucidation of the mechanism of SFTSV infection in vivo and the assessment of drugs for SFTS treatment.
Wang, Guobao; Corwin, Michael T; Olson, Kristin A; Badawi, Ramsey D; Sarkar, Souvik
2018-05-30
The hallmark of nonalcoholic steatohepatitis is hepatocellular inflammation and injury in the setting of hepatic steatosis. Recent work has indicated that dynamic 18F-FDG PET with kinetic modeling has the potential to assess hepatic inflammation noninvasively, while static FDG-PET did not show a promise. Because the liver has dual blood supplies, kinetic modeling of dynamic liver PET data is challenging in human studies. The objective of this study is to evaluate and identify a dual-input kinetic modeling approach for dynamic FDG-PET of human liver inflammation. Fourteen human patients with nonalcoholic fatty liver disease were included in the study. Each patient underwent one-hour dynamic FDG-PET/CT scan and had liver biopsy within six weeks. Three models were tested for kinetic analysis: traditional two-tissue compartmental model with an image-derived single-blood input function (SBIF), model with population-based dual-blood input function (DBIF), and modified model with optimization-derived DBIF through a joint estimation framework. The three models were compared using Akaike information criterion (AIC), F test and histopathologic inflammation reference. The results showed that the optimization-derived DBIF model improved the fitting of liver time activity curves and achieved lower AIC values and higher F values than the SBIF and population-based DBIF models in all patients. The optimization-derived model significantly increased FDG K1 estimates by 101% and 27% as compared with traditional SBIF and population-based DBIF. K1 by the optimization-derived model was significantly associated with histopathologic grades of liver inflammation while the other two models did not provide a statistical significance. In conclusion, modeling of DBIF is critical for kinetic analysis of dynamic liver FDG-PET data in human studies. The optimization-derived DBIF model is more appropriate than SBIF and population-based DBIF for dynamic FDG-PET of liver inflammation. © 2018 Institute of Physics and Engineering in Medicine.
Gómez-de la Fuente, F J; Martínez-Rodríguez, I; de Arcocha-Torres, M; Quirce, R; Jiménez-Bonilla, J; Martínez-Amador, N; Banzo, I
11 C-choline PET/CT has demonstrated good results in the restaging of prostate cancer (PCa) with high serum prostate specific antigen (PSA), but its use in patients with low serum PSA is controversial. Our aim was to evaluate the contribution of 11 C-choline PET/CT in patients with PCa, biochemical relapse and PSA <1 ng/ml. Fifty consecutive patients (mean age: 65.9±5.6 years) with biochemical relapse of PCa and serum PSA <1ng/ml were evaluated retrospectively. PET/CT was performed 20min after intravenous administration of 555-740 MBq of 11 C-choline. Minimum follow up time was 30 months. Twenty-one out of 50 patients (42%) had an abnormal 11 C-choline PET/CT. In 7 out of 21 patients (14%) tumor was confirmed (4 in prostatic bed, 4 in pelvic lymph nodes, 2 in mediastinal lymph nodes and one synchronous sigmoid carcinoma), and in all cases the initial therapeutic planning was modified. In 2 patients (4%) subsequent tests diagnosed a benign disease (one sarcoidosis, one tuberculosis sequelae) and in 3 patients (6%) they ruled out pathology. The other 9 patients (18%) had no further assessment (7 mediastinal and 4 pelvic lymph nodes). Twenty-nine out of 50 patients (58%) had a normal PET/CT. At 30 months, follow up recurrence was confirmed only in 2 of these patients. 11 C-choline PET/CT proved its usefulness in demonstrating tumor in 14% of patients with BR of PCa and serum PSA <1ng/ml, with therapeutic implications. In 4% of patients a benign condition was detected. A normal 11 C-choline PET/CT was associated with a very low rate of recurrence at 30 months. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
Win, Thida; Screaton, Nicholas J; Porter, Joanna C; Ganeshan, Balaji; Maher, Toby M; Fraioli, Francesco; Endozo, Raymondo; Shortman, Robert I; Hurrell, Lynn; Holman, Beverley F; Thielemans, Kris; Rashidnasab, Alaleh; Hutton, Brian F; Lukey, Pauline T; Flynn, Aiden; Ell, Peter J; Groves, Ashley M
2018-05-01
There is a lack of prognostic biomarkers in idiopathic pulmonary fibrosis (IPF) patients. The objective of this study is to investigate the potential of 18 F-FDG-PET/ CT to predict mortality in IPF. A total of 113 IPF patients (93 males, 20 females, mean age ± SD: 70 ± 9 years) were prospectively recruited for 18 F-FDG-PET/CT. The overall maximum pulmonary uptake of 18 F-FDG (SUV max ), the minimum pulmonary uptake or background lung activity (SUV min ), and target-to-background (SUV max / SUV min ) ratio (TBR) were quantified using routine region-of-interest analysis. Kaplan-Meier analysis was used to identify associations of PET measurements with mortality. We also compared PET associations with IPF mortality with the established GAP (gender age and physiology) scoring system. Cox analysis assessed the independence of the significant PET measurement(s) from GAP score. We investigated synergisms between pulmonary 18 F-FDG-PET measurements and GAP score for risk stratification in IPF patients. During a mean follow-up of 29 months, there were 54 deaths. The mean TBR ± SD was 5.6 ± 2.7. Mortality was associated with high pulmonary TBR (p = 0.009), low forced vital capacity (FVC; p = 0.001), low transfer factor (TLCO; p < 0.001), high GAP index (p = 0.003), and high GAP stage (p = 0.003). Stepwise forward-Wald-Cox analysis revealed that the pulmonary TBR was independent of GAP classification (p = 0.010). The median survival in IPF patients with a TBR < 4.9 was 71 months, whilst in those with TBR > 4.9 was 24 months. Combining PET data with GAP data ("PET modified GAP score") refined the ability to predict mortality. A high pulmonary TBR is independently associated with increased risk of mortality in IPF patients.
18F-FDG positron emission tomography/computed tomography in infective endocarditis.
Salomäki, Soile Pauliina; Saraste, Antti; Kemppainen, Jukka; Bax, Jeroen J; Knuuti, Juhani; Nuutila, Pirjo; Seppänen, Marko; Roivainen, Anne; Airaksinen, Juhani; Pirilä, Laura; Oksi, Jarmo; Hohenthal, Ulla
2017-02-01
The diagnosis of infective endocarditis (IE), especially the diagnosis of prosthetic valve endocarditis (PVE) is challenging since echocardiographic findings are often scarce in the early phase of the disease. We studied the use of 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in IE. Sixteen patients with suspected PVE and 7 patients with NVE underwent visual evaluation of 18 F-FDG-PET/CT. 18 F-FDG uptake was measured also semiquantitatively as maximum standardized uptake value (SUV max ) and target-to-background ratio (TBR). The modified Duke criteria were used as a reference. There was strong, focal 18 F-FDG uptake in the area of the affected valve in all 6 cases of definite PVE, in 3 of 5 possible PVE cases, and in 2 of 5 rejected cases. In all patients with definite PVE, SUV max of the affected valve was higher than 4 and TBR higher than 1.8. In contrast to PVE, only 1 of 7 patients with NVE had uptake of 18 F-FDG by PET/CT in the valve area. Embolic infectious foci were detected in 58% of the patients with definite IE. 18 F-FDG-PET/CT appears to be a sensitive method for the detection of paravalvular infection associated with PVE. Instead, the sensitivity of PET/CT is limited in NVE.
The use of radiation-induced graft polymerization for modification of polymer track membranes
NASA Astrophysics Data System (ADS)
Shtanko, N. I.; Kabanov, V. Ya.; Apel, P. Yu.; Yoshida, M.
1999-05-01
Track membranes (TM) made of poly(ethylene terephtalate) (PET) and polypropylene (PP) films have a number of peculiarities as compared with other ones. They have high mechanical strength at a low thickness, narrow pore size distribution, low content of extractables. However, TM have some disadvantages such as low chemical resistance in alkaline media (PET TM), the low water flow rate due to the hydrophobic nature of their surface. The use of radiation-induced graft polymerization makes it possible to improve the basic characteristics of TM. In this communication our results on the modification of PET and PP TM are presented. The modified membranes were prepared by radiation-induced graft polymerization from the liquid phase. Three methods of grafting were used: (a) the direct method in argon atmosphere; (b) the pre-irradiation of TM in air followed by grafting in argon atmosphere; (c) pre-irradiation in vacuum followed by grafting in vacuum without contacting oxygen. The aim of the work was to investigate some properties of TM modified by grafted poly(methylvinyl pyridine) (PMVP) and poly(N-isopropylacrylamide) (PNIPAAM). It was shown that the modification of TM with hydrophilic polymer results in the growth of the water flow rate. In the past few years many works have been devoted to the synthesis of new polymers - the so-called "intelligent" materials - such as PNIPAAM. However, it is very difficult to make thin membranes of this polymer. Recently, it has been proposed to manufacture composite membranes by grafting stimulus-responsive polymers onto TM. Following this principle, we prepared thermosensitive membranes by the radiation-induced graft polymerization of N-isopropylacrylamide (NIPAAM) onto PET TM. PET TM with the pore size of about 1 μm and pore density of 10 6 cm -2 were first inserted into a solution of NIPAAM containing inhibitor of homopolymerization (CuCl 2) and then exposed to the γ-rays from a 60Co source. The transport properties of the grafted TM were investigated. The permeation of water through the TM was controlled by temperature. The grafted TM exhibited almost the same transition temperature (about 33°C) as that of PNIPAAM.
Comparison of Monte Carlo simulated and measured performance parameters of miniPET scanner
NASA Astrophysics Data System (ADS)
Kis, S. A.; Emri, M.; Opposits, G.; Bükki, T.; Valastyán, I.; Hegyesi, Gy.; Imrek, J.; Kalinka, G.; Molnár, J.; Novák, D.; Végh, J.; Kerek, A.; Trón, L.; Balkay, L.
2007-02-01
In vivo imaging of small laboratory animals is a valuable tool in the development of new drugs. For this purpose, miniPET, an easy to scale modular small animal PET camera has been developed at our institutes. The system has four modules, which makes it possible to rotate the whole detector system around the axis of the field of view. Data collection and image reconstruction are performed using a data acquisition (DAQ) module with Ethernet communication facility and a computer cluster of commercial PCs. Performance tests were carried out to determine system parameters, such as energy resolution, sensitivity and noise equivalent count rate. A modified GEANT4-based GATE Monte Carlo software package was used to simulate PET data analogous to those of the performance measurements. GATE was run on a Linux cluster of 10 processors (64 bit, Xeon with 3.0 GHz) and controlled by a SUN grid engine. The application of this special computer cluster reduced the time necessary for the simulations by an order of magnitude. The simulated energy spectra, maximum rate of true coincidences and sensitivity of the camera were in good agreement with the measured parameters.
NIRF Optical/PET Dual-Modal Imaging of Hepatocellular Carcinoma Using Heptamethine Carbocyanine Dye
Zhang, Caiqin; Zhao, Yong; Zhao, Ningning; Tan, Dengxu; Zhang, He; Chen, Xue; Zhang, Hai; An, Jiaze
2018-01-01
Combining near-infrared fluorescence (NIRF) and nuclear imaging techniques provides a novel approach for hepatocellular carcinoma (HCC) diagnosis. Here, we report the synthesis and characteristics of a dual-modality NIRF optical/positron emission tomography (PET) imaging probe using heptamethine carbocyanine dye and verify its feasibility in both nude mice and rabbits with orthotopic xenograft liver cancer. This dye, MHI-148, is an effective cancer-specific NIRF imaging agent and shows preferential uptake and retention in liver cancer. The corresponding NIRF imaging intensity reaches 109/cm2 tumor area at 24 h after injection in mice with HCC subcutaneous tumors. The dye can be further conjugated with radionuclide 68Ga (68Ga-MHI-148) for PET tracing. We applied the dual-modality methodology toward the detection of HCC in both patient-derived orthotopic xenograft (PDX) models and rabbit orthotopic transplantation models. NIRF/PET images showed clear tumor delineation after probe injection (MHI-148 and 68Ga-MHI-148). The tumor-to-muscle (T/M) standardized uptake value (SUV) ratios were obtained from PET at 1 h after injection of 68Ga-MHI-148, which was helpful for effectively capturing small tumors in mice (0.5 cm × 0.3 cm) and rabbits (1.2 cm × 1.8 cm). This cancer-targeting NIRF/PET dual-modality imaging probe provides a proof of principle for noninvasive detection of deep-tissue tumors in mouse and rabbit and is a promising technique for more accurate and early detection of HCC. PMID:29706843
Peterson, Lanell M; O'Sullivan, Janet; Wu, Qian Vicky; Novakova-Jiresova, Alena; Jenkins, Isaac; Lee, Jean H; Shields, Andrew; Montgomery, Susan; Linden, Hannah M; Gralow, Julie R; Gadi, Vijayakrishna K; Muzi, Mark; Kinahan, Paul E; Mankoff, David A; Specht, Jennifer M
2018-05-10
Assessing therapy response of breast cancer bone metastases is challenging. In retrospective studies, serial 18 F-FDG PET was predictive of time to skeletal related events (tSRE) and time-to-progression (TTP). 18 F-NaF PET improves bone metastasis detection compared to bone scans. We prospectively tested 18 F-FDG PET and 18 F-NaF PET to predict tSRE, TTP, and overall survival (OS) in patients with bone-dominant metastatic breast cancer (BD MBC). Methods: Patients with BD MBC were imaged with 18 F-FDG PET and 18 F-NaF PET prior to starting new therapy (scan1) and again at a range of times centered around approximately 4 months later (scan2). SUV max and SULpeak were recorded for a single index lesion and up to 5 most dominant lesions for each scan. tSRE, TTP, and OS were assessed exclusive of the PET images. Univariate Cox regression was performed to test the association between clinical endpoints and 18 F-FDG PET and 18 F-NaF PET measures. mPERCIST (Modified PET Response Criteria in Solid Tumors) criteria were also applied. Survival curves for mPERCIST compared response categories of Complete Response+Partial Response+Stable Disease versus Progressive Disease (CR+PR+SD vs PD) for tSRE, TTP, and OS. Results: Twenty-eight patients were evaluated. Higher FDG SULpeak at scan2 predicted shorter time to tSRE ( P = <0.001) and TTP ( P = 0.044). Higher FDG SUV max at scan2 predicted a shorter time to tSRE ( P = <0.001). A multivariable model using FDG SUV max of the index lesion at scan1 plus the difference in SUV max of up to 5 lesions between scans was predictive for tSRE and TTP. Among 24 patients evaluable by 18 F-FDG PET mPERCIST, tSRE and TTP were longer in responders (CR, PR, or stable) compared to non-responders (PD) ( P = 0.007, 0.028 respectively), with a trend toward improved survival ( P = 0.1). An increase in the uptake between scans of up to 5 lesions by 18 F-NaF PET was associated with longer OS ( P = 0.027). Conclusion: Changes in 18 F-FDG PET parameters during therapy are predictive of tSRE and TTP, but not OS. mPERCIST evaluation in bone lesions may be useful in assessing response to therapy and is worthy of evaluation in multicenter, prospective trials. Serial 18 F-NaF PET was associated with OS, but was not useful for predicting TTP or tSRE in BD MBC. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Beyond clay - using selective extractions to improve predictions of soil carbon content
NASA Astrophysics Data System (ADS)
Rasmussen, C.; Berhe, A. A.; Blankinship, J. C.; Crow, S. E.; Druhan, J. L.; Heckman, K. A.; Keiluweit, M.; Lawrence, C. R.; Marin-Spiotta, E.; Plante, A. F.; Schaedel, C.; Schimel, J.; Sierra, C. A.; Thompson, A.; Wagai, R.; Wieder, W. R.
2016-12-01
A central component of modern soil carbon (C) models is the use of clay content to scale the relative partitioning of decomposing plant material to respiration and mineral stabilized soil C. However, numerous pedon to plot scale studies indicate that other soil mineral parameters, such as Fe- or Al-oxyhydroxide content and specific surface area, may be more effective than clay alone for predicting soil C content and stabilization. Here we directly address the following question: Are there soil physicochemical parameters that represent mineral C association and soil C content that can replace or be used in conjunction with clay content as scalars in soil C models. We explored the relationship of soil C content to a number of soil physicochemical and physiographic parameters using the National Cooperative Soil Survey database that contains horizon level data for > 62,000 pedons spanning global ecoregions and geographic areas. The data indicated significant variation in the degree of correlation among soil C, clay and Fe-/Al-oxyhydroxides with increasing moisture variability. Specifically, dry, water-limited systems (PET/MAP > 1) presented strong positive correlations between clay and soil C, that decreased significantly to little or no correlation in wet, energy-limited systems (PET/MAP < 1). In contrast, the correlation of soil C to oxalate extractable Al+Fe increased significantly with increasing moisture availability. This pattern was particularly well expressed for subsurface B horizons. Multivariate analyses indicated similar patterns, with clear climate and ecosystem level variation in the degree of correlation among soil C and soil physicochemical properties. The results indicate a need to modify current soil C models to incorporate additional C partitioning parameters that better account for climate and ecoregion variability in C stabilization mechanisms.
Sachpekidis, Christos; Thieke, Christian; Askoxylakis, Vasileios; Nicolay, Nils H; Huber, Peter E; Thomas, Michael; Dimitrakopoulou, Georgia; Debus, Juergen; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia
2015-01-01
Aim of this study was to evaluate and compare, by means of dynamic and static PET/CT, the distribution patterns and pharmacokinetics of fluorine-18 fluorodeoxyglucose ((18)F-FDG) and of fluorine-18-fluoromisonidazole ((18)F-FMISO) in non-small cell lung cancer (NSCLC) patients scheduled for intensity modulated radiation therapy (IMRT). Thirteen patients suffering from inoperable stage III NSCLC underwent PET/CTs with (18)F-FDG and (18)F-FMISO for tumor metabolism and hypoxia assessment accordingly. Evaluation of PET/CT studies was based on visual analysis, semi-quantitative (SUV) calculations and absolute quantitative estimations, after application of a two-tissue compartment model and a non-compartmental approach. (18)F-FDG PET/CT revealed all thirteen primary lung tumors as sites of increased (18)F-FDG uptake. Six patients demonstrated also in total 43 (18)F-FDG avid metastases; these patients were excluded from radiotherapy. (18)F-MISO PET/CT demonstrated 12/13 primary lung tumors with faint tracer uptake. Only one tumor was clearly (18)F-FMISO avid, (SUVaverage = 3.4, SUVmax = 5.0). Mean values for (18)F-FDG, as derived from dPET/CT data, were SUVaverage = 8.9, SUVmax = 15.1, K1 = 0.23, k2 = 0.53, k3 = 0.17, k4 = 0.02, influx = 0.05 and fractal dimension (FD) = 1.25 for the primary tumors. The respective values for (18)F-FMISO were SUVaverage = 1.4, SUVmax = 2.2, K1 = 0.26, k2 = 0.56, k3 = 0.06, k4 = 0.06, influx = 0.02 and FD = 1.14. No statistically significant correlation was observed between the two tracers. (18)F-FDG PET/CT changed therapy management in six patients, by excluding them from planned IMRT. (18)F-FMISO PET/CT revealed absence of significant tracer uptake in the majority of the (18)F-FDG avid NSCLCs. Lack of correlation between the two tracers' kinetics indicates that they reflect different molecular mechanisms and implies the discordance between increased glycolysis and hypoxia in the malignancy.
Sachpekidis, Christos; Thieke, Christian; Askoxylakis, Vasileios; Nicolay, Nils H; Huber, Peter E; Thomas, Michael; Dimitrakopoulou, Georgia; Debus, Juergen; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia
2015-01-01
Aim of this study was to evaluate and compare, by means of dynamic and static PET/CT, the distribution patterns and pharmacokinetics of fluorine-18 fluorodeoxyglucose (18F-FDG) and of fluorine-18-fluoromisonidazole (18F-FMISO) in non-small cell lung cancer (NSCLC) patients scheduled for intensity modulated radiation therapy (IMRT). Thirteen patients suffering from inoperable stage III NSCLC underwent PET/CTs with 18F-FDG and 18F-FMISO for tumor metabolism and hypoxia assessment accordingly. Evaluation of PET/CT studies was based on visual analysis, semi-quantitative (SUV) calculations and absolute quantitative estimations, after application of a two-tissue compartment model and a non-compartmental approach. 18F-FDG PET/CT revealed all thirteen primary lung tumors as sites of increased 18F-FDG uptake. Six patients demonstrated also in total 43 18F-FDG avid metastases; these patients were excluded from radiotherapy. 18F-MISO PET/CT demonstrated 12/13 primary lung tumors with faint tracer uptake. Only one tumor was clearly 18F-FMISO avid, (SUVaverage = 3.4, SUVmax = 5.0). Mean values for 18F-FDG, as derived from dPET/CT data, were SUVaverage = 8.9, SUVmax = 15.1, K1 = 0.23, k2 = 0.53, k3 = 0.17, k4 = 0.02, influx = 0.05 and fractal dimension (FD) = 1.25 for the primary tumors. The respective values for 18F-FMISO were SUVaverage = 1.4, SUVmax = 2.2, K1 = 0.26, k2 = 0.56, k3 = 0.06, k4 = 0.06, influx = 0.02 and FD = 1.14. No statistically significant correlation was observed between the two tracers. 18F-FDG PET/CT changed therapy management in six patients, by excluding them from planned IMRT. 18F-FMISO PET/CT revealed absence of significant tracer uptake in the majority of the 18F-FDG avid NSCLCs. Lack of correlation between the two tracers’ kinetics indicates that they reflect different molecular mechanisms and implies the discordance between increased glycolysis and hypoxia in the malignancy. PMID:25973334
Gamie, Sherief; El-Maghraby, Tarek
2008-01-01
Bone scintigraphy including Single Photon Emission Computed Tomography (SPECT) is known for its role in the diagnosis of low back pain disorders. Positron Emission Tomography (PET) with (18)F (Flouride-18) as a tracer can be used to carry out bone scans with improved image quality. With the addition of CT, simultaneous PET/CT fused images provide more accurate anatomical details. The objectives of this work are to assess the use of (18)F-PET/CT in patients with back pain and suspected facetogenic pain, and to find the frequency of facet arthropathy versus disc disease abnormalities. 67 patients who presented with back pain underwent routine X-ray, CT and/or MRI, which failed to identify a clear cause, were referred to (18)F-PET/CT. Among the main group, a subset of 25 patients had previous spine surgery consisting of laminectomy or discectomy (17 patients) and lumbar fusion (8 patients). The PET/CT scan was acquired on a GE VCT 64-Slice combined scanner. Imaging started 45-60 minutes after administration of 12-15 mCi (444-555 MBq) of (18)F-Fluoride. The PET scan was acquired from the skull base through the inguinal region in 3D mode at 2 minutes/bed. A lowresolution, non-contrast CT scan was also acquired for anatomic localization and attenuation correction. The (18)F-PET/CT showed abnormal uptake in the spine in 56 patients, with an overall detection ability of 84%. Facet joints as a cause of back pain was much more frequent (25 with abnormal scans). One-third (36%) of the patients showed multiple positive uptake in both facet joints and disc areas (20/56). The patients were further divided into two groups. Group A consisted of 42 patients (63%) with back pain and no previous operative procedures, and the (18)F-PET/CT showed a high sensitivity (88%) in identifying the source of pain in 37/42 patients. Group B included 25 patients (37%) with prior lumbar fusion or laminectomy, in which the PET/CT showed positive uptake in 76% (19/25 patients). (18)F-PET/CT showed positive uptake in all patients (100%) with a history of pain after lumbar fusion, while in the laminectomy subgroup only 11 cases (65%) showed positive focal uptake. (18)F-PET/CT has a potential use in evaluating adult patients with back pain. It has a promising role in identifying causes of persistent back pain following vertebral surgical interventions.
Zheleznyak, Alexander; Garbow, Joel R; Neeman, Michal; Lapi, Suzanne E
2015-01-01
The goal of this work was to study the efficacy of the positron emission tomography (PET) tracers 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) and 64Cu-diacetyl-bis(N4-methylthiosemicarbazone) ([64Cu]ATSM) and in monitoring placental and fetal functional response to acute hyperoxia in late-term pregnant mice subjected to experimentally induced chronic hypoxia. E15 mice were maintained at 12% inspired oxygen for 72 hours and then imaged during oxygen inhalation with either [18F]FDG to monitor nutrient transport or 64Cu-ATSM to establish the presence of hypoxia. Computed tomography (CT) with contrast allowed clear visualization of both placentas and fetuses. The average ratio of fetal to placental [18F]FDG uptake was 0.45 ± 0.1 for the hypoxic animals and 0.55 ± 0.1 for the normoxic animals, demonstrating a significant decrease (p = .0002) in placental function in dams exposed to chronic hypoxic conditions. Hypoxic placentas and fetuses retained more 64Cu-ATSM compared to normoxic placentas and fetuses. Herein we report first-in-mouse PET imaging of fetuses employing both tracers [18F]FDG (metabolism) and 64Cu-ATSM (hypoxia). [18F]FDG PET/CT imaging allowed clear visualization of placental-fetal structures and supported quantification of tracer uptake, making this a sensitive tool for monitoring placental function in preclinical rodent models. These measurements illustrate the potentially irreversible damage generated by chronic exposure to hypoxia, which cannot be corrected by acute exposure to hyperoxia.
Cardiorespiratory Fitness Attenuates the Influence of Amyloid on Cognition.
Schultz, Stephanie A; Boots, Elizabeth A; Almeida, Rodrigo P; Oh, Jennifer M; Einerson, Jean; Korcarz, Claudia E; Edwards, Dorothy F; Koscik, Rebecca L; Dowling, Maritza N; Gallagher, Catherine L; Bendlin, Barbara B; Christian, Bradley T; Zetterberg, Henrik; Blennow, Kaj; Carlsson, Cynthia M; Asthana, Sanjay; Hermann, Bruce P; Sager, Mark A; Johnson, Sterling C; Stein, James H; Okonkwo, Ozioma C
2015-11-01
The aim of this study was to examine cross-sectionally whether higher cardiorespiratory fitness (CRF) might favorably modify amyloid-β (Aβ)-related decrements in cognition in a cohort of late-middle-aged adults at risk for Alzheimer's disease (AD). Sixty-nine enrollees in the Wisconsin Registry for Alzheimer's Prevention participated in this study. They completed a comprehensive neuropsychological exam, underwent 11C Pittsburgh Compound B (PiB)-PET imaging, and performed a graded treadmill exercise test to volitional exhaustion. Peak oxygen consumption (VO2peak) during the exercise test was used as the index of CRF. Forty-five participants also underwent lumbar puncture for collection of cerebrospinal fluid (CSF) samples, from which Aβ42 was immunoassayed. Covariate-adjusted regression analyses were used to test whether the association between Aβ and cognition was modified by CRF. There were significant VO2peak*PiB-PET interactions for Immediate Memory (p=.041) and Verbal Learning & Memory (p=.025). There were also significant VO2peak*CSF Aβ42 interactions for Immediate Memory (p<.001) and Verbal Learning & Memory (p<.001). Specifically, in the context of high Aβ burden, that is, increased PiB-PET binding or reduced CSF Aβ42, individuals with higher CRF exhibited significantly better cognition compared with individuals with lower CRF. In a late-middle-aged, at-risk cohort, higher CRF is associated with a diminution of Aβ-related effects on cognition. These findings suggest that exercise might play an important role in the prevention of AD.
Cardiorespiratory fitness attenuates the influence of amyloid on cognition
Schultz, Stephanie A.; Boots, Elizabeth A.; Almeida, Rodrigo P.; Oh, Jennifer M.; Einerson, Jean; Korcarz, Claudia E.; Edwards, Dorothy F.; Koscik, Rebecca L.; Dowling, Maritza N.; Gallagher, Catherine L.; Bendlin, Barbara B.; Christian, Bradley T.; Zetterberg, Henrik; Blennow, Kaj; Carlsson, Cynthia M.; Asthana, Sanjay; Hermann, Bruce P.; Sager, Mark A.; Johnson, Sterling C.; Stein, James H.; Okonkwo, Ozioma C.
2015-01-01
Objective To examine cross-sectionally whether higher cardiorespiratory fitness (CRF) might favorably modify amyloid-β (Aβ)-related decrements in cognition in a cohort of late-middle-aged adults at risk for Alzheimer's disease (AD). Methods Sixty-nine enrollees in the Wisconsin Registry for Alzheimer's Prevention participated in this study. They completed a comprehensive neuropsychological exam, underwent 11C Pittsburgh Compound B (PiB)-PET imaging, and performed a graded treadmill exercise test to volitional exhaustion. Peak oxygen consumption (VO2peak) during the exercise test was used as the index of CRF. Forty-five participants also underwent lumbar puncture for collection of cerebrospinal fluid (CSF) samples, from which Aβ42 was immunoassayed. Covariate-adjusted regression analyses were used to test whether the association between Aβ and cognition was modified by CRF. Results There were significant VO2peak*PiB-PET interactions for Immediate Memory (p= .041) and Verbal Learning & Memory (p= .025). There were also significant VO2peak*CSF Aβ42 interactions for Immediate Memory (p<.001) and Verbal Learning & Memory (p <.001). Specifically, in the context of high Aβ burden—i.e., increased PiB-PET binding or reduced CSF Aβ42—individuals with higher CRF exhibited significantly better cognition compared with individuals with lower CRF. Conclusion In a late-middle-aged, at-risk cohort, higher CRF is associated with a diminution of Aβ-related effects on cognition. These findings suggest that exercise might play an important role in the prevention of AD. PMID:26581795
Abou-Yousef, Hussein; Khattab, Tawfik A; Youssef, Yehia A; Al-Balakocy, Naser; Kamel, Samir
2017-08-01
A simple, portable and highly sensitive naked-eye test strip is successfully prepared for optical detection of gaseous and aqueous alkaline analytes. Novel pH-sensory tricyanofuran-hydrazone (TCFH) disperse colorant containing a hydrazone recognition functional moiety is successfully synthesized via azo-coupling reaction between active methyl-containing tricyanofuran (TCF) heterocycle and diazonium salt of 4-aminobenzaldehyde followed by Knoevenagel condensation with malononitrile. UV-vis absorption spectra display solvatochromism and reversible color changes of the TCFH solution in dimethyl sulfoxide in response to pH variations. We investigate the preparation of hydrophobic cellulose/polyethylene terephthalate composites characterized by their high affinity for disperse dyes. Composite films made from CA, Cell/CA, PET/CA, and Cell/PET-CA are produced via solvent-casting procedure using 10-30% modified cellulose or modified polyethylene terephthalate. The mechanical properties and morphologies of these composite films are investigated. The prepared pH-sensory hydrazone-based disperse dye is then applied to dye the produced cellulose-based composite films employing the high temperature pressure dyeing procedure. The produced halochromic PET-CA-TCFH test strip provide an instant visible signal from orange to purple upon exposure to alkaline conditions as proved by the coloration measurements. The sensor strip exhibits high sensitivity and quick detection toward ammonia in both of aqueous and vapor phases by naked-eye observations at room temperature and atmospheric pressure. Copyright © 2017 Elsevier B.V. All rights reserved.
Baum, Richard P.; Kulkarni, Harshad R.
2012-01-01
The acronym THERANOSTICS epitomizes the inseparability of diagnosis and therapy, the pillars of medicine and takes into account personalized management of disease for a specific patient. Molecular phenotypes of neoplasms can be determined by molecular imaging with specific probes using positron emission tomography (PET), single photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), or optical methods, so that the treatment is specifically targeted against the tumor and its environment. To meet these demands, we need to define the targets, ligands, coupling and labeling chemistry, the most appropriate radionuclides, biodistribution modifiers, and finally select the right patients for the personalized treatment. THERANOSTICS of neuroendocrine tumors (NETs) using Ga-68 labeled tracers for diagnostics with positron emission tomography/ computed tomography (PET/CT), and using Lu-177 or other metallic radionuclides for radionuclide therapy by applying the same peptide proves that personalized radionuclide therapy today is already a fact and not a fiction. PMID:22768024
Baum, Richard P; Kulkarni, Harshad R
2012-01-01
The acronym THERANOSTICS epitomizes the inseparability of diagnosis and therapy, the pillars of medicine and takes into account personalized management of disease for a specific patient. Molecular phenotypes of neoplasms can be determined by molecular imaging with specific probes using positron emission tomography (PET), single photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), or optical methods, so that the treatment is specifically targeted against the tumor and its environment. To meet these demands, we need to define the targets, ligands, coupling and labeling chemistry, the most appropriate radionuclides, biodistribution modifiers, and finally select the right patients for the personalized treatment. THERANOSTICS of neuroendocrine tumors (NETs) using Ga-68 labeled tracers for diagnostics with positron emission tomography/ computed tomography (PET/CT), and using Lu-177 or other metallic radionuclides for radionuclide therapy by applying the same peptide proves that personalized radionuclide therapy today is already a fact and not a fiction.
Chen, L; Lai, C; Marchewka, R; Berry, R M; Tam, K C
2016-07-21
Structural colors and photoluminescence have been widely used for anti-counterfeiting and security applications. We report for the first time the use of CdS quantum dot (QD)-functionalized cellulose nanocrystals (CNCs) as building blocks to fabricate nanothin films via layer-by-layer (LBL) self-assembly for anti-counterfeiting applications. Both negatively- and positively-charged CNC/QD nanohybrids with a high colloidal stability and a narrow particle size distribution were prepared. The controllable LBL coating process was characterized by scanning electron microscopy and ellipsometry. The rigid structure of CNCs leads to nanoporous structured films on poly(ethylene terephthalate) (PET) substrates with high transmittance (above 70%) over the entire range of visible light and also resulted in increased hydrophilicity (contact angles of ∼40 degrees). Nanothin films on PET substrates showed good flexibility and enhanced stability in both water and ethanol. The modified PET films with structural colors from thin-film interference and photoluminescence from QDs can be used in anti-counterfeiting applications.
Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer.
Bradley, Jeffrey; Thorstad, Wade L; Mutic, Sasa; Miller, Tom R; Dehdashti, Farrokh; Siegel, Barry A; Bosch, Walter; Bertrand, Rudi J
2004-05-01
Locoregional failure remains a significant problem for patients receiving definitive radiation therapy alone or combined with chemotherapy for non-small-cell lung cancer (NSCLC). Positron emission tomography (PET) with [(18)F]fluoro-2-deoxy-d-glucose (FDG) has proven to be a valuable diagnostic and staging tool for NSCLC. This prospective study was performed to determine the impact of treatment simulation with FDG-PET and CT on radiation therapy target volume definition and toxicity profiles by comparison to simulation with computed tomography (CT) scanning alone. Twenty-six patients with Stages I-III NSCLC were studied. Each patient underwent sequential CT and FDG-PET simulation on the same day. Immobilization devices used for both simulations included an alpha cradle, a flat tabletop, 6 external fiducial markers, and a laser positioning system. A radiation therapist participated in both simulations to reproduce the treatment setup. Both the CT and fused PET/CT image data sets were transferred to the radiation treatment planning workstation for contouring. Each FDG-PET study was reviewed with the interpreting nuclear radiologist before tumor volumes were contoured. The fused PET/CT images were used to develop the three-dimensional conformal radiation therapy (3DCRT) plan. A second physician, blinded to the results of PET, contoured the gross tumor volumes (GTV) and planning target volumes (PTV) from the CT data sets, and these volumes were used to generate mock 3DCRT plans. The PTV was defined by a 10-mm margin around the GTV. The two 3DCRT plans for each patient were compared with respect to the GTV, PTV, mean lung dose, volume of normal lung receiving > or =20 Gy (V20), and mean esophageal dose. The FDG-PET findings altered the AJCC TNM stage in 8 of 26 (31%) patients; 2 patients were diagnosed with metastatic disease based on FDG-PET and received palliative radiation therapy. Of the 24 patients who were planned with 3DCRT, PET clearly altered the radiation therapy volume in 14 (58%), as follows. PET helped to distinguish tumor from atelectasis in all 3 patients with atelectasis. Unsuspected nodal disease was detected by PET in 10 patients, and 1 patient had a separate tumor focus detected within the same lobe of the lung. Increases in the target volumes led to increases in the mean lung dose, V20, and mean esophageal dose. Decreases in the target volumes in the patients with atelectasis led to decreases in these normal-tissue toxicity parameters. Radiation targeting with fused FDG-PET and CT images resulted in alterations in radiation therapy planning in over 50% of patients by comparison with CT targeting. The increasing availability of integrated PET/CT units will facilitate the use of this technology for radiation treatment planning. A confirmatory multicenter, cooperative group trial is planned within the Radiation Therapy Oncology Group.
Ladefoged, Claes N; Hansen, Adam E; Keller, Sune H; Fischer, Barbara M; Rasmussen, Jacob H; Law, Ian; Kjær, Andreas; Højgaard, Liselotte; Lauze, Francois; Beyer, Thomas; Andersen, Flemming L
2015-12-01
In the absence of CT or traditional transmission sources in combined clinical positron emission tomography/magnetic resonance (PET/MR) systems, MR images are used for MR-based attenuation correction (MR-AC). The susceptibility effects due to metal implants challenge MR-AC in the neck region of patients with dental implants. The purpose of this study was to assess the frequency and magnitude of subsequent PET image distortions following MR-AC. A total of 148 PET/MR patients with clear visual signal voids on the attenuation map in the dental region were included in this study. Patients were injected with [(18)F]-FDG, [(11)C]-PiB, [(18)F]-FET, or [(64)Cu]-DOTATATE. The PET/MR data were acquired over a single-bed position of 25.8 cm covering the head and neck. MR-AC was based on either standard MR-ACDIXON or MR-ACINPAINTED where the susceptibility-induced signal voids were substituted with soft tissue information. Our inpainting algorithm delineates the outer contour of signal voids breaching the anatomical volume using the non-attenuation-corrected PET image and classifies the inner air regions based on an aligned template of likely dental artifact areas. The reconstructed PET images were evaluated visually and quantitatively using regions of interests in reference regions. The volume of the artifacts and the computed relative differences in mean and max standardized uptake value (SUV) between the two PET images are reported. The MR-based volume of the susceptibility-induced signal voids on the MR-AC attenuation maps was between 1.6 and 520.8 mL. The corresponding/resulting bias of the reconstructed tracer distribution was localized mainly in the area of the signal void. The mean and maximum SUVs averaged across all patients increased after inpainting by 52% (± 11%) and 28% (± 11%), respectively, in the corrected region. SUV underestimation decreased with the distance to the signal void and correlated with the volume of the susceptibility artifact on the MR-AC attenuation map. Metallic dental work may cause severe MR signal voids. The resulting PET/MR artifacts may exceed the actual volume of the dental fillings. The subsequent bias in PET is severe in regions in and near the signal voids and may affect the conspicuity of lesions in the mandibular region.
Apoptosis imaging studies in various animal models using radio-iodinated peptide.
Kwak, Wonjung; Ha, Yeong Su; Soni, Nisarg; Lee, Woonghee; Park, Se-Il; Ahn, Heesu; An, Gwang Il; Kim, In-San; Lee, Byung-Heon; Yoo, Jeongsoo
2015-01-01
Apoptosis has a role in many medical disorders and treatments; hence, its non-invasive evaluation is one of the most riveting research topics. Currently annexin V is used as gold standard for imaging apoptosis. However, several drawbacks, including high background, slow body clearance, make it a suboptimum marker for apoptosis imaging. In this study, we radiolabeled the recently identified histone H1 targeting peptide (ApoPep-1) and evaluated its potential as a new apoptosis imaging agent in various animal models. ApoPep-1 (CQRPPR) was synthesized, and an extra tyrosine residue was added to its N-terminal end for radiolabeling. This peptide was radiolabeled with (124)I and (131)I and was tested for its serum stability. Surgery- and drug-induced apoptotic rat models were prepared for apoptosis evaluation, and PET imaging was performed. Doxorubicin was used for xenograft tumor treatment in mice, and the induced apoptosis was studied. Tumor metabolism and proliferation were assessed by [(18)F]FDG and [(18)F]FLT PET imaging and compared with ApoPep-1 after doxorubicin treatment. The peptide was radiolabeled at high purity, and it showed reasonably good stability in serum. Cell death was easily imaged by radiolabeled ApoPep-1 in an ischemia surgery model. And, liver apoptosis was more clearly identified by ApoPep-1 rather than [(124)I]annexin V in cycloheximide-treated models. Three doxorubicin doses inhibited tumor growth, which was evaluated by 30-40% decreases of [(18)F]FDG and [(18)F]FLT PET uptake in the tumor area. However, ApoPep-1 demonstrated more than 200% increase in tumor uptake after chemotherapy, while annexin V did not show any meaningful uptake in the tumor compared with the background. Biodistribution data were also in good agreement with the microPET imaging results. All of the experimental data clearly demonstrated high potential of the radiolabeled ApoPep-1 for in vivo apoptosis imaging.
Validation of a small-animal PET simulation using GAMOS: a GEANT4-based framework
NASA Astrophysics Data System (ADS)
Cañadas, M.; Arce, P.; Rato Mendes, P.
2011-01-01
Monte Carlo-based modelling is a powerful tool to help in the design and optimization of positron emission tomography (PET) systems. The performance of these systems depends on several parameters, such as detector physical characteristics, shielding or electronics, whose effects can be studied on the basis of realistic simulated data. The aim of this paper is to validate a comprehensive study of the Raytest ClearPET small-animal PET scanner using a new Monte Carlo simulation platform which has been developed at CIEMAT (Madrid, Spain), called GAMOS (GEANT4-based Architecture for Medicine-Oriented Simulations). This toolkit, based on the GEANT4 code, was originally designed to cover multiple applications in the field of medical physics from radiotherapy to nuclear medicine, but has since been applied by some of its users in other fields of physics, such as neutron shielding, space physics, high energy physics, etc. Our simulation model includes the relevant characteristics of the ClearPET system, namely, the double layer of scintillator crystals in phoswich configuration, the rotating gantry, the presence of intrinsic radioactivity in the crystals or the storage of single events for an off-line coincidence sorting. Simulated results are contrasted with experimental acquisitions including studies of spatial resolution, sensitivity, scatter fraction and count rates in accordance with the National Electrical Manufacturers Association (NEMA) NU 4-2008 protocol. Spatial resolution results showed a discrepancy between simulated and measured values equal to 8.4% (with a maximum FWHM difference over all measurement directions of 0.5 mm). Sensitivity results differ less than 1% for a 250-750 keV energy window. Simulated and measured count rates agree well within a wide range of activities, including under electronic saturation of the system (the measured peak of total coincidences, for the mouse-sized phantom, was 250.8 kcps reached at 0.95 MBq mL-1 and the simulated peak was 247.1 kcps at 0.87 MBq mL-1). Agreement better than 3% was obtained in the scatter fraction comparison study. We also measured and simulated a mini-Derenzo phantom obtaining images with similar quality using iterative reconstruction methods. We concluded that the overall performance of the simulation showed good agreement with the measured results and validates the GAMOS package for PET applications. Furthermore, its ease of use and flexibility recommends it as an excellent tool to optimize design features or image reconstruction techniques.
TPS(PET)-A TPS-based approach for in vivo dose verification with PET in proton therapy.
Frey, K; Bauer, J; Unholtz, D; Kurz, C; Krämer, M; Bortfeld, T; Parodi, K
2014-01-06
Since the interest in ion-irradiation for tumour therapy has significantly increased over the last few decades, intensive investigations are performed to improve the accuracy of this form of patient treatment. One major goal is the development of methods for in vivo dose verification. In proton therapy, a PET (positron emission tomography)-based approach measuring the irradiation-induced tissue activation inside the patient has been already clinically implemented. The acquired PET images can be compared to an expectation, derived under the assumption of a correct treatment application, to validate the particle range and the lateral field position in vivo. In the context of this work, TPSPET is introduced as a new approach to predict proton-irradiation induced three-dimensional positron emitter distributions by means of the same algorithms of the clinical treatment planning system (TPS). In order to perform additional activity calculations, reaction-channel-dependent input positron emitter depth distributions are necessary, which are determined from the application of a modified filtering approach to the TPS reference depth dose profiles in water. This paper presents the implementation of TPSPET on the basis of the research treatment planning software treatment planning for particles. The results are validated in phantom and patient studies against Monte Carlo simulations, and compared to β(+)-emitter distributions obtained from a slightly modified version of the originally proposed one-dimensional filtering approach applied to three-dimensional dose distributions. In contrast to previously introduced methods, TPSPET provides a faster implementation, the results show no sensitivity to lateral field extension and the predicted β(+)-emitter densities are fully consistent to the planned treatment dose as they are calculated by the same pencil beam algorithms. These findings suggest a large potential of the application of TPSPET for in vivo dose verification in the daily clinical routine.
NASA Astrophysics Data System (ADS)
Pierre, Cynthia
Numerous approaches can be used to modify polymer properties. In this thesis, it is demonstrated that an innovative, continuous, industrially scalable process called solid-state shear pulverization (SSSP) can be used to enhance polymer properties with and without the addition of nanofillers. The SSSP process employs a modified twin-screw extruder in which the barrel is cooled rather than heated, resulting in the polymer being processed at a temperature below its glass transition temperature, if the polymer is amorphous, or its melt transition temperature, if the polymer is semi-crystalline. The material processed via SSSP experiences high levels of shear and compressive stresses, resulting in many repeated fragmentation and fusion steps during pulverization, which can lead to mechanochemistry. This research provides the first in-depth study on the effect of SSSP processing on the molecular structure as well as physical properties of homopolymers. Rheological characterization has demonstrated an increase in the melt viscosity of pulverized poly(ethylene terephthalate) (PET), which can be ascribed to the in situ formation of lightly branched PET. Further evidence of branched PET is provided via a dramatic increase in the rate of crystallization of the pulverized samples. These results suggest that SSSP processing can enhance the reuse and recyclability of PET. While SSSP processing has dramatic effects on the structure of polyesters and consequently their properties, a mild effect is observed for polyolefins. This thesis also demonstrates via a combination of methods that the well-exfoliated state can be achieved via SSSP processing of various polymer nanocomposites, using as-received, unmodified fillers. For example, extensive comparisons are made concerning the thermal stability in air or nitrogen atmosphere of polypropylene (PP)/clay, PP/graphite, and PP/carbon nanotube (CNT) nanocomposites made by SSSP. These comparisons suggest that the mechanism by which CNTs enhance the thermal stability of PP differs from the mechanism associated with clay and graphite.
Cha, Ji Hyeon; Lee, Sheen-Woo; Park, Kyeongsoon; Moon, Dae Hyuk; Kim, Kwangmeyung; Biswal, Sandip
2012-01-01
Objective To evaluate the potential and correlation between near-infrared fluorescence (NIRF) imaging using cyanine 5.5 conjugated with hydrophobically modified glycol chitosan nanoparticles (HGC-Cy5.5) and 18F-fluorodeoxyglucose-positron emission tomography (18F-FDG-PET) imaging of collagen-induced arthritis (CIA). Materials and Methods We used 10 CIA and 3 normal mice. Nine days after the injecting collagen twice, microPET imaging was performed 40 minutes after the intravenous injection of 9.3 MBq 18F-FDG in 200 µL PBS. One day later, NIRF imaging was performed two hours after the intravenous injection of HGC-cy5.5 (5 mg/kg). We assessed the correlation between these two modalities in the knees and ankles of CIA mice. Results The mean standardized uptake values of 18F-FDG for knees and ankles were 1.68 ± 0.76 and 0.79 ± 0.71, respectively, for CIA mice; and 0.57 ± 0.17 and 0.54 ± 0.20 respectively for control mice. From the NIRF images, the total photon counts per 30 mm2 for knees and ankles were 2.32 ± 1.54 × 105 and 2.75 ± 1.51 × 105, respectively, for CIA mice, and 1.22 ± 0.27 × 105 and 0.88 ± 0.24 × 105, respectively, for control mice. These two modalities showed a moderate correlation for knees (r = 0.604, p = 0.005) and ankles (r = 0.464, p = 0.039). Moreover, both HGC-Cy5.5 (p = 0.002) and 18F-FDG-PET (p = 0.005) imaging also showed statistically significant differences between CIA and normal mice. Conclusion NIRF imaging using HGC-Cy5.5 was moderately correlated with 18F-FDG-PET imaging in the CIA model. As such, HGC-Cy5.5 imaging can be used for the early detection of rheumatoid arthritis. PMID:22778567
NASA Astrophysics Data System (ADS)
Hee, Allan George
Part I. The work presented herein describes efforts to develop general techniques for the synthesis of transition metal clusters and the manipulation of their properties. In Chapter 2, it is demonstrated that a modified metal atom reactor allows for the vaporization, passivation, and isolation of metal-chalcogenide clusters from their parent binary solids. Among the clusters produced by this method were Cr6S8(PEt3)6, Fe4S 4(PEt3)4, Co6S8(PEt 3)6, Cu6S4(PEt3)6, Cu12S6(PEt3)8, and Cu26Se 13(PEt3)14. To create single-molecule magnets with higher demagnetization barriers, we are developing metal-cyanide systems which exhibit highly adjustable magnetic behavior. Chapter 3 reports an attempt to introduce magnetic anisotropy into a MnCr6 cluster. Replacement of CrIII with Mo III resulted in the assembly of K[(Me3tacn)6MnMo 6(CN)18](ClO4)3 (Me3tacn = N,N',N″ -trimethyl-1,4,7-triazacyclononane)---the first well-documented example of a cyano-bridged single-molecule magnet. Recently, it was demonstrated that replacing Me3tacn with the less sterically hindering tach (tach = cis,cis-1,3,5-triaminocyclohexane) in the face-centered cubic cluster [(tach)8Cr8Ni 6(CN)24]Br12 provides greater access to the cluster cavity. Chapter 4 describes my efforts to probe the selectivity of this cluster toward inclusion of various guests. Part II. Successful implementation of student-centered curricula reforms requires the creation of a measurement instrument for monitoring whether the curricula are being used as intended. The creation and development of an observation instrument would greatly contribute to this effort. To develop a theoretically sound construct map, it is necessary to review the literature and conduct our own investigations of approaches to science teaching. Chapter 2 presents the findings of these investigations and their contributions to our understanding of the construct. Using these findings, the Science Teaching Observation Protocol (STOP) was created and designed to measure two subconstructs: intentions and strategies. Chapter 3 details the first pilot test of STOP and analysis of the collected data. In Chapter 4, the theoretical shortcomings of the instrument are analyzed and discussed. Modified versions of the intention and strategy subconstruct maps are presented.
Rødal, Jan; Rusten, Espen; Søvik, Åste; Skogmo, Hege Kippenes; Malinen, Eirik
2013-10-01
Radiotherapy causes alterations in tumor biology, and non-invasive early assessment of such alterations may become useful for identifying treatment resistant disease. The purpose of the current work is to assess changes in vascular and metabolic features derived from functional imaging of canine head and neck tumors during fractionated radiotherapy. Material and methods. Three dogs with spontaneous head and neck tumors received intensity-modulated radiotherapy (IMRT). Contrast-enhanced cone beam computed tomography (CE-CBCT) at the treatment unit was performed at five treatment fractions. Dynamic (18)FDG-PET (D-PET) was performed prior to the start of radiotherapy, at mid-treatment and at 3-12 weeks after the completion of treatment. Tumor contrast enhancement in the CE-CBCT images was used as a surrogate for tumor vasculature. Vascular and metabolic tumor parameters were further obtained from the D-PET images. Changes in these tumor parameters were assessed, with emphasis on intra-tumoral distributions. Results. For all three patients, metabolic imaging parameters obtained from D-PET decreased from the pre- to the inter-therapy session. Correspondingly, for two of three patients, vascular imaging parameters obtained from both CE-CBCT and D-PET increased. Only one of the tumors showed a clear metabolic response after therapy. No systematic changes in the intra-tumor heterogeneity in the imaging parameters were found. Conclusion. Changes in vascular and metabolic parameters could be detected by the current functional imaging methods. Vascular tumor features from CE-CBCT and D-PET corresponded well. CE-CBCT is a potential method for easy response assessment when the patient is at the treatment unit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lecomte, Roger; Arpin, Louis; Beaudoin, Jean-Franç
Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time andmore » energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathias, C.J.; Welch, M.J.; Raichle, M.E.
1990-03-01
Copper(II) pyruvaldehyde bis(N4-methylthiosemicarbazone) (Cu-PTSM), copper(II) pyruvaldehyde bis(N4-dimethylthiosemicarbazone) (Cu-PTSM2), and copper(II) ethylglyoxal bis(N4-methylthiosemicarbazone) (Cu-ETSM), have been proposed as PET tracers for cerebral blood flow (CBF) when labeled with generator-produced 62Cu (t1/2 = 9.7 min). To evaluate the potential of Cu-PTSM for CBF PET studies, baboon single-pass cerebral extraction measurements and PET imaging were carried out with the use of 67Cu (t1/2 = 2.6 days) and 64Cu (t1/2 = 12.7 hr), respectively. All three chelates were extracted into the brain with high efficiency. There was some clearance of all chelates in the 10-50-sec time frame and Cu-PTSM2 continued to clear. Cu-PTSM andmore » Cu-ETSM have high residual brain activity. PET imaging of baboon brain was carried out with the use of (64Cu)-Cu-PTSM. For comparison with the 64Cu brain image, a CBF (15O-labeled water) image (40 sec) was first obtained. Qualitatively, the H2(15)O and (64Cu)-Cu-PTSM images were very similar; for example, a comparison of gray to white matter uptake resulted in ratios of 2.42 for H2(15)O and 2.67 for Cu-PTSM. No redistribution of 64Cu was observed in 2 hr of imaging, as was predicted from the single-pass study results. Quantitative determination of blood flow using Cu-PTSM showed good agreement with blood flow determined with H2(15)O. This data suggests that (62Cu)-Cu-PTSM may be a useful generator-produced radiopharmaceutical for blood flow studies with PET.« less
Assessment of thermal comfort level at pedestrian level in high-density urban area of Hong Kong
NASA Astrophysics Data System (ADS)
Ma, J.; Ng, E.; Yuan, C.; Lai, A.
2015-12-01
Hong Kong is a subtropical city which is very hot and humid in the summer. Pedestrians commonly experience thermal discomfort. Various studies have shown that the tall bulky buildings intensify the urban heat island effect and reduce urban air ventilation. However, relatively few studies have focused on modeling the thermal load at pedestrian level (~ 2 m). This study assesses the thermal comfort level, quantified by PET (Physiological Equivalent Temperature), using a GIS - based simulation approach. A thermal comfort level map shows the PET value of a typical summer afternoon in the high building density area. For example, the averaged PET in Sheung Wan is about 41 degree Celsius in a clear day and 38 degree Celsius in a cloudy day. This map shows where the walkways, colonnades, and greening is most needed. In addition, given a start point, a end point, and weather data, we generate the most comfort walking routes weighted by the PET. In the simulation, shortwave irradiance is calculated using the topographic radiation model (Fu and Rich, 1999) under various cloud cover scenarios; longwave irradiance is calculated based the radiative transfer equation (Swinbank, 1963). Combining these two factors, Tmrt (mean radiant temperature) is solved. And in some cases, the Tmrt differ more than 40 degree Celsius between areas under the sun and under the shades. Considering thermal load and wind information, we found that shading from buildings has stronger effect on PET than poor air ventilation resulted from dense buildings. We predict that pedestrians would feel more comfortable (lower PET) in a hot summer afternoon when walking in the higher building density area.
Reactive modification of polyesters and their blends
NASA Astrophysics Data System (ADS)
Wan, Chen
2004-12-01
As part of a broader research effort to investigate the chemical modification of polyesters by reactive processing a low molecular weight (MW) unsaturated polyester (UP) and a higher MW saturated polyester, polyethylene terephthalate (PET), alone or blended with polypropylene (PP) were melt processed in a batch mixer and continuous twin screw extruders. Modification was monitored by on-line rheology and the products were characterized primarily by off-line rheology, morphology and thermal analysis. Efforts were made to establish processing/property relationships and provide an insight of the accompanying structural changes. The overall response of the reactively modified systems was found to be strongly dependent on the component characteristics, blend composition, type and concentrations of reactive additives and processing conditions. The work concluded that UP can be effectively modified through reactive melt processing. Its melt viscosity and MW can be increased through chemical reactions between organic peroxides (POX) and chain unsaturation or between MgO and carboxyl/hydroxyl end groups. Reactive blending of PP/UP blends through peroxide modification gave finer and more uniform morphology than unreacted blends and at a given PP/UP weight ratio more thermoplastic elastomers-like rheological behavior. This is due to the continuously decreasing viscosity ratio of PP/UP towards unity by the competing reactions between POX and the blend components and formation of PP-UP copolymers which serve as in-situ compatibilizers to promote better interfacial adhesion. Kinetics of the competing reactions were analyzed through a developed model. In addition to POX concentration and mixing efficiency, rheology and morphology of UP/PP bends were significantly affected by the addition of inorganic and organic coagents. Addition of coagents such as a difunctional maleimide, MgO and/or an anhydride functionalized PP during reactive blending offers effective means for tailoring the desired rheological and structural characteristics of the final products for potential applications such as low density extrusion foaming or compatibilization of immiscible polymer blends. Important modification conditions through coagents are identified and reaction mechanisms are proposed. A high MW saturated polyester, PET, can also be rheologically modified in extruders through low MW multifunctional anhydride and epoxy compounds by chain extension/branching. Several such modifiers were successfully screened in terms of their reactivity towards PET under controlled reactive extrusion conditions. A dianhydride with medium reactivity was then successfully used in a one-step reactive modification/extrusion foaming process to produce low density foams. A similar process was successfully used to produce small cell size foams from a four component system containing PET, PP and lesser amounts of a low molecular weight multifunctional epoxy compound and an acid functionalized polyolefin, the latter acting as compatibilizers.
Evaluating the purity of a {sup 57}Co flood source by PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
DiFilippo, Frank P., E-mail: difilif@ccf.org
2014-11-01
Purpose: Flood sources of {sup 57}Co are commonly used for quality control of gamma cameras. Flood uniformity may be affected by the contaminants {sup 56}Co and {sup 58}Co, which emit higher energy photons. Although vendors specify a maximum combined {sup 56}Co and {sup 58}Co activity, a convenient test for flood source purity that is feasible in a clinical environment would be desirable. Methods: Both {sup 56}Co and {sup 58}Co emit positrons with branching 19.6% and 14.9%, respectively. As is known from {sup 90}Y imaging, a positron emission tomography (PET) scanner is capable of quantitatively imaging very weak positron emission inmore » a high single-photon background. To evaluate this approach, two {sup 57}Co flood sources were scanned with a clinical PET/CT multiple times over a period of months. The {sup 56}Co and {sup 58}Co activity was clearly visible in the reconstructed PET images. Total impurity activity was quantified from the PET images after background subtraction of prompt gamma coincidences. Results: Time-of-flight PET reconstruction was highly beneficial for accurate image quantification. Repeated measurements of the positron-emitting impurities showed excellent agreement with an exponential decay model. For both flood sources studied, the fit parameters indicated a zero intercept and a decay half-life consistent with a mixture of {sup 56}Co and {sup 58}Co. The total impurity activity at the reference date was estimated to be 0.06% and 0.07% for the two sources, which was consistent with the vendor’s specification of <0.12%. Conclusions: The robustness of the repeated measurements and a thorough analysis of the detector corrections and physics suggest that the accuracy is acceptable and that the technique is feasible. Further work is needed to validate the accuracy of this technique with a calibrated high resolution gamma spectrometer as a gold standard, which was not available for this study, and for other PET detector models.« less
Liu, Ren-Shyan; Chou, Ta-Kai; Chang, Chih-Hsien; Wu, Chun-Yi; Chang, Chi-Wei; Chang, Tsui-Jung; Wang, Shih-Jen; Lin, Wuu-Jyh; Wang, Hsin-Ell
2009-04-01
2-Deoxy-2-[(18)F]fluoro-d-glucose ([(18)F]FDG), [(18)F]fluoroacetate ([(18)F]FAc) and [(18)F]fluoromisonidazole ([(18)F]FMISO) were all considered to be positron emission tomography (PET) probes for tumor diagnosis, though based on different rationale of tissue uptake. This study compared the biodistribution, pharmacokinetics and imaging of these three tracers in a sarcoma- and inflammation-bearing mouse model. C3H mice were inoculated with 2x10(5) KHT sarcoma cells in the right thigh on Day 0. Turpentine oil (0.1 ml) was injected in the left thigh on Day 11 to induce inflammatory lesion. Biodistribution, pharmacokinetics and microPET imaging of [(18)F]FMISO, [(18)F]FDG and [(18)F]FAc were performed on Day 14 after tumor inoculation. The inflammatory lesions were clearly visualized by [(18)F]FDG/microPET and autoradiography at 3 days after turpentine oil injection. The tumor-to-muscle and inflammatory lesion-to-muscle ratios derived from microPET imaging were 6.79 and 1.48 for [(18)F]FMISO, 8.12 and 4.69 for [(18)F]FDG and 3.72 and 3.19 for [(18)F]FAc at 4 h post injection, respectively. Among these, the tumor-to-inflammation ratio was the highest (4.57) for [(18)F]FMISO compared with that of [(18)F]FDG (1.73) and [(18)F]FAc (1.17), whereas [(18)F]FAc has the highest bioavailability (area under concentration of radiotracer vs. time curve, 116.2 hxpercentage of injected dose per gram of tissue). MicroPET images and biodistribution studies showed that the accumulation of [(18)F]FMISO in the tumor is significantly higher than that in inflammatory lesion at 4 h post injection. [(18)F]FDG and [(18)F]FAc delineated both tumor and inflammatory lesions. Our results demonstrated the potential of [(18)F]FMISO/PET in distinguishing tumor from inflammatory lesion.
Value of ¹⁸F-FDG PET/CT in the diagnosis of primary gastric cancer via stomach distension.
Ma, Quanmei; Xin, Jun; Zhao, Zhoushe; Guo, Qiyong; Yu, Shupeng; Xu, Weina; Liu, Changping; Zhai, Wei
2013-06-01
To clarify the usefulness of (18)F-FDG PET/CT for detecting primary gastric cancer via gastric distention using a mixture of milk and Diatrizoate Meglumine. A total of 68 patients (male: 47, female: 21; age: 41-87 years) suspected of gastric carcinoma underwent (18)F-FDG PET/CT imaging. After whole-body PET/CT imaging in a fasting state, the patients drank a measured amount of milk with Diatrizoate Meglumine. Local gastric district PET/CT imaging was performed 30 min later. The imaging was analyzed by semi-quantitative analysis, standardized uptake value (SUV) of the primary tumor was measured in a region of interest. The diagnosis results were confirmed by gastroscopy, pathology, and follow-up results. Of the 68 patients, 56 malignant gastric neoplasm patients (male: 37, female: 19) were conformed. The sensitivity, specificity, positive predictive value and negative predictive value of fasting whole-body PET/CT imaging for a primary malignant tumor were 92.9%, 75.0%, 94.5%, and 69.0%, respectively. The values for distension with a mixture of milk and Diatrizoate Meglumine were 91.1%, 91.7%, 98.1%, and 68.8%, respectively. The area under the curve was 0.919 ± 0.033 and 0.883 ± 0.066 for the diagnosis of gastric cancer with SUVmax in a fasting state and after intake of mixture respectively, the differences were not statistically significant (P=0.359). Using gastric distension with a mixture of milk and Diatrizoate Meglumine, the mean ratio of the lesion's SUVmax to the adjacent gastric wall SUVmax increased significantly from 3.30 ± 3.05 to 13.50 ± 15.05, which was statistically significant (P<0.001). (18)F-FDG PET/CT imaging is highly accurate for the diagnosis of primary gastric carcinoma. Gastric distention can display the lesions more clearly, however, it cannot significantly improve diagnostic accuracy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Zhang, Zhengxing; Lau, Joseph; Kuo, Hsiou-Ting; Zhang, Chengcheng; Colpo, Nadine; Bénard, François; Lin, Kuo-Shyan
2017-05-15
The potent and selective prostanoid EP4 receptor antagonist CJ-042794 was radiolabeled with 18 F, and evaluated for imaging EP4 receptor expression in cancer with positron emission tomography (PET). The fluorination precursor, arylboronic acid pinacol ester 4, was prepared in 4 steps with 42% overall yield. 18 F-CJ-042794 was synthesized via a copper-mediated 18 F-fluorination reaction followed by base hydrolysis, and was obtained in 1.5±1.1% (n=2) decay-corrected radiochemical yield. PET/CT imaging and biodistribution studies in mice showed that 18 F-CJ-042794 was excreted through both renal and hepatobiliary pathways with significant retention in blood. The EP4-receptor-expressing LNCaP prostate cancer xenografts were clearly visualized in PET images with 1.12±0.08%ID/g (n=5) uptake value and moderate tumour-to-muscle contrast ratio (2.73±0.22) at 1h post-injection. However, the tumour uptake was nonspecific as it could not be blocked by co-injection of cold standard, precluding the application of 18 F-CJ-042794 for PET imaging of EP4 receptor expression in cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pyrhönen, K; Kulmala, P; Näyhä, S
2018-03-01
Children whose 11th fetal week falls in pollen season (spring) reportedly have an increased risk of sensitization to food allergens. No such finding has been reported for pet allergens. The aim of the study was to (i) evaluate the incidence of pet (dog and cat) sensitization according to the season of the 11th fetal week and (ii) whether the association between pet exposure and respective sensitization is modified by the coincidence of the 11th fetal week with pollen season. The study population comprised all children (born between 2001 and 2006) in the province of South Karelia, Finland (N = 5920). Their data of immunoglobulin E antibodies and skin prick tests to pet allergens (N = 538) were collected from patient records and linked with questionnaire data on pet exposure. The seasonal incidence peak of cat sensitization was observed in children whose 11th fetal week occurred in June (7.4%) and that of dog sensitization in April (3.8%) and June (4.7%). The relative rate (RR) for cat sensitization was 2.92 (95% CI 1.40-6.08) in children with cat exposure alone, 8.53 (4.07-17.86) in children with cat and fetal pollen exposures and 0.61 (0.20-1.83) in children exposed to pollen alone, compared with children without these exposures. The respective RRs for dog sensitization were 2.17 (1.13-4.19), 4.40 (2.19-8.83) and 1.65 (0.77-3.53). Coincidence of the first fetal trimester with pollen season strengthens the association between pet exposure and respective sensitization. Pollen exposure at early pregnancy may deviate immune system towards Th2-type reactivity promoting development of specific allergy in case allergen exposure occurred. Therefore, primary prevention of allergic diseases may need to begin during early pregnancy. © 2017 John Wiley & Sons Ltd.
Hostetler, Eric D; Walji, Abbas M; Zeng, Zhizhen; Miller, Patricia; Bennacef, Idriss; Salinas, Cristian; Connolly, Brett; Gantert, Liza; Haley, Hyking; Holahan, Marie; Purcell, Mona; Riffel, Kerry; Lohith, Talakad G; Coleman, Paul; Soriano, Aileen; Ogawa, Aimie; Xu, Serena; Zhang, Xiaoping; Joshi, Elizabeth; Della Rocca, Joseph; Hesk, David; Schenk, David J; Evelhoch, Jeffrey L
2016-10-01
A PET tracer is desired to help guide the discovery and development of disease-modifying therapeutics for neurodegenerative diseases characterized by neurofibrillary tangles (NFTs), the predominant tau pathology in Alzheimer disease (AD). We describe the preclinical characterization of the NFT PET tracer 18 F-MK-6240. In vitro binding studies were conducted with 3 H-MK-6240 in tissue slices and homogenates from cognitively normal and AD human brain donors to evaluate tracer affinity and selectivity for NFTs. Immunohistochemistry for phosphorylated tau was performed on human brain slices for comparison with 3 H-MK-6240 binding patterns on adjacent brain slices. PET studies were performed with 18 F-MK-6240 in monkeys to evaluate tracer kinetics and distribution in the brain. 18 F-MK-6240 monkey PET studies were conducted after dosing with unlabeled MK-6240 to evaluate tracer binding selectivity in vivo. The 3 H-MK-6240 binding pattern was consistent with the distribution of phosphorylated tau in human AD brain slices. 3 H-MK-6240 bound with high affinity to human AD brain cortex homogenates containing abundant NFTs but bound poorly to amyloid plaque-rich, NFT-poor AD brain homogenates. 3 H-MK-6240 showed no displaceable binding in the subcortical regions of human AD brain slices and in the hippocampus/entorhinal cortex of non-AD human brain homogenates. In monkey PET studies, 18 F-MK-6240 displayed rapid and homogeneous distribution in the brain. The 18 F-MK-6240 volume of distribution stabilized rapidly, indicating favorable tracer kinetics. No displaceable binding was observed in self-block studies in rhesus monkeys, which do not natively express NFTs. Moderate defluorination was observed as skull uptake. 18 F-MK-6240 is a promising PET tracer for the in vivo quantification of NFTs in AD patients. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Patel, Daksha; Kell, Arnold; Simard, Benoit; Xiang, Bo; Lin, Hung Yu; Tian, Ganghong
2011-02-01
A new class of nanoparticle-based dual-modality positron emission tomography/magnetic resonance imaging (PET/MRI) contrast agents has been developed. The probe consists of a superparamagnetic iron oxide (SPIO) or manganese oxide core coated with 3,4-dihydroxy-D,L-phenylalanine (DL-DOPA). The chelator 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) was conjugated to DOPA termini. The DOTA modified nanoparticles allow chelation of copper for PET imaging. These surface functionalized nanoparticle-based probes have been characterized by various analytical techniques. The cell-labeling efficacy, cytotoxicity and relaxivity of these nanoparticles have been evaluated and compared with the same properties of one of the most commonly utilized MRI contrast agents, Feridex(®). Evidently, this new nanoparticle has a great potential for use in cell tracking with MRI and PET in the absence of transfecting agent. It is noteworthy that there is a sharp increase in r(2) relaxivity of these nanoparticles on coordination with Cu(2+) ions. Thus these iron oxide nanoparticles can also be explored as the smart magnetic resonance (MR) sensor for the detection of micromolar changes in copper concentration for neurodegenerative diseases such as Alzheimer's disease, Menkes and Wilson's diseases, amyotrophic lateral sclerosis and prion diseases. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.
Positron emission tomography scans obtained for the evaluation of cognitive dysfunction.
Silverman, Daniel H S; Mosconi, Lisa; Ercoli, Linda; Chen, Wei; Small, Gary W
2008-07-01
The degree of intactness of human cognitive functioning for a given individual spans a wide spectrum, ranging from normal to severely demented. The differential diagnosis for the causes of impairment along that spectrum is also wide, and often difficult to distinguish clinically, which has led to an increasing role for neuroimaging tools in that evaluation. The most frequent causes of dementia are neurodegenerative disorders, Alzheimer's disease being the most prevalent among them, and they produce significant alterations in brain metabolism, with devastating neuropathologic, clinical, social, and economic consequences. These alterations are detectable through positron emission tomography (PET), even in their earliest stages. The most commonly performed PET studies of the brain are performed with (18)F-fluorodeoxyglucose as the imaged radiopharmaceutical. Such scans have demonstrated diagnostic and prognostic utility for clinicians evaluating patients with cognitive impairment and in distinguishing among primary neurodegenerative disorders and other etiologies contributing to cognitive decline. In addition to focusing on the effects on cerebral metabolism examined with (18)F-fluorodeoxyglucose PET, some other changes occurring in the brains of cognitively impaired patients assessable with other radiotracers will be considered. As preventive and disease-modifying treatments are developed, early detection of accurately diagnosed disease processes facilitated by the use of PET has the potential to substantially impact on the enormous human toll exacted by these diseases.
NASA Astrophysics Data System (ADS)
Moroizumi, T.; Yamamoto, M.; Miura, T.
2008-12-01
It is important to estimate accurately a water balance in watershed for proposing a reuse of water resources and a proper settlement of water utilization. Evapotranspiration (ET) is an important factor of water balance. Therefore, it is needed to estimate accurately the actual ET. The objective of this study is to estimate accurately monthly actual ET in Yoshii, Asahi, and Takahashi River watersheds in Okayama prefecture from 1999 to 2000. The monthly actual ET was calculated by a Morton and a modified Brutsaert and Stricker (B&S) method, using Automated Meteorological Data Acquisition Systems (AMeDAS) in the basin. The actual ET was estimated using land covers which were classified in 11 categories. The land covers includes the effects of albedo. The actual ET was related to the elevation at each AMeDAS station. Using this relationship, the actual ET at the 1 or 5 km grid-interval mesh in the basin was calculated, and finally, the distribution of actual ET was mapped. The monthly ET estimated by the modified B&S method were smaller than that by Morton method which showed a same tendency as the Penman potential ET (PET). The annual values of Morton"fs ET, modified B&S"fs ET, and PET were estimated as 796, 645, and 800 mm, respectively. The ET by the modified B&S was larger in hilly and mountainous areas than in settlement or city. In general, it was a reasonable result because city or settlement areas were covered with concrete and asphalt and the ET was controlled.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tewari, Sanjit O., E-mail: tewaris@mskcc.org; Petre, Elena N., E-mail: petree@mskcc.org; Osborne, Joseph, E-mail: osbornej@mskcc.org
2013-12-15
A 68-year-old female with colorectal cancer developed a metachronous isolated fluorodeoxyglucose-avid (FDG-avid) segment 5/6 gallbladder fossa hepatic lesion and was referred for percutaneous ablation. Pre-procedure computed tomography (CT) images demonstrated a distended gallbladder abutting the segment 5/6 hepatic metastasis. In order to perform ablation with clear margins and avoid direct puncture and aspiration of the gallbladder, cholecystokinin was administered intravenously to stimulate gallbladder contraction before hydrodissection. Subsequently, the lesion was ablated successfully with sufficient margins, of greater than 1.0 cm, using microwave with ultrasound and FDG PET/CT guidance. The patient tolerated the procedure very well and was discharged home themore » next day.« less
Ibaraki, Masanobu; Sato, Kaoru; Mizuta, Tetsuro; Kitamura, Keishi; Miura, Shuichi; Sugawara, Shigeki; Shinohara, Yuki; Kinoshita, Toshibumi
2009-09-01
A modified version of row-action maximum likelihood algorithm (RAMLA) using a 'subset-dependent' relaxation parameter for noise suppression, or dynamic RAMLA (DRAMA), has been proposed. The aim of this study was to assess the capability of DRAMA reconstruction for quantitative (15)O brain positron emission tomography (PET). Seventeen healthy volunteers were studied using a 3D PET scanner. The PET study included 3 sequential PET scans for C(15)O, (15)O(2) and H (2) (15) O. First, the number of main iterations (N (it)) in DRAMA was optimized in relation to image convergence and statistical image noise. To estimate the statistical variance of reconstructed images on a pixel-by-pixel basis, a sinogram bootstrap method was applied using list-mode PET data. Once the optimal N (it) was determined, statistical image noise and quantitative parameters, i.e., cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral metabolic rate of oxygen (CMRO(2)) and oxygen extraction fraction (OEF) were compared between DRAMA and conventional FBP. DRAMA images were post-filtered so that their spatial resolutions were matched with FBP images with a 6-mm FWHM Gaussian filter. Based on the count recovery data, N (it) = 3 was determined as an optimal parameter for (15)O PET data. The sinogram bootstrap analysis revealed that DRAMA reconstruction resulted in less statistical noise, especially in a low-activity region compared to FBP. Agreement of quantitative values between FBP and DRAMA was excellent. For DRAMA images, average gray matter values of CBF, CBV, CMRO(2) and OEF were 46.1 +/- 4.5 (mL/100 mL/min), 3.35 +/- 0.40 (mL/100 mL), 3.42 +/- 0.35 (mL/100 mL/min) and 42.1 +/- 3.8 (%), respectively. These values were comparable to corresponding values with FBP images: 46.6 +/- 4.6 (mL/100 mL/min), 3.34 +/- 0.39 (mL/100 mL), 3.48 +/- 0.34 (mL/100 mL/min) and 42.4 +/- 3.8 (%), respectively. DRAMA reconstruction is applicable to quantitative (15)O PET study and is superior to conventional FBP in terms of image quality.
Wangerin, Kristen A; Baratto, Lucia; Khalighi, Mohammad Mehdi; Hope, Thomas A; Gulaka, Praveen K; Deller, Timothy W; Iagaru, Andrei H
2018-06-06
Gallium-68-labeled radiopharmaceuticals pose a challenge for scatter estimation because their targeted nature can produce high contrast in these regions of the kidneys and bladder. Even small errors in the scatter estimate can result in washout artifacts. Administration of diuretics can reduce these artifacts, but they may result in adverse events. Here, we investigated the ability of algorithmic modifications to mitigate washout artifacts and eliminate the need for diuretics or other interventions. The model-based scatter algorithm was modified to account for PET/MRI scanner geometry and challenges of non-FDG tracers. Fifty-three clinical 68 Ga-RM2 and 68 Ga-PSMA-11 whole-body images were reconstructed using the baseline scatter algorithm. For comparison, reconstruction was also processed with modified sampling in the single-scatter estimation and with an offset in the scatter tail-scaling process. None of the patients received furosemide to attempt to decrease the accumulation of radiopharmaceuticals in the bladder. The images were scored independently by three blinded reviewers using the 5-point Likert scale. The scatter algorithm improvements significantly decreased or completely eliminated the washout artifacts. When comparing the baseline and most improved algorithm, the image quality increased and image artifacts were reduced for both 68 Ga-RM2 and for 68 Ga-PSMA-11 in the kidneys and bladder regions. Image reconstruction with the improved scatter correction algorithm mitigated washout artifacts and recovered diagnostic image quality in 68 Ga PET, indicating that the use of diuretics may be avoided.
Experimental evaluation of the resolution improvement provided by a silicon PET probe.
Brzeziński, K; Oliver, J F; Gillam, J; Rafecas, M; Studen, A; Grkovski, M; Kagan, H; Smith, S; Llosá, G; Lacasta, C; Clinthorne, N H
2016-09-01
A high-resolution PET system, which incorporates a silicon detector probe into a conventional PET scanner, has been proposed to obtain increased image quality in a limited region of interest. Detailed simulation studies have previously shown that the additional probe information improves the spatial resolution of the reconstructed image and increases lesion detectability, with no cost to other image quality measures. The current study expands on the previous work by using a laboratory prototype of the silicon PET-probe system to examine the resolution improvement in an experimental setting. Two different versions of the probe prototype were assessed, both consisting of a back-to-back pair of 1-mm thick silicon pad detectors, one arranged in 32 × 16 arrays of 1.4 mm × 1.4 mm pixels and the other in 40 × 26 arrays of 1.0 mm × 1.0 mm pixels. Each detector was read out by a set of VATAGP7 ASICs and a custom-designed data acquisition board which allowed trigger and data interfacing with the PET scanner, itself consisting of BGO block detectors segmented into 8 × 6 arrays of 6 mm × 12 mm × 30 mm crystals. Limited-angle probe data was acquired from a group of Na-22 point-like sources in order to observe the maximum resolution achievable using the probe system. Data from a Derenzo-like resolution phantom was acquired, then scaled to obtain similar statistical quality as that of previous simulation studies. In this case, images were reconstructed using measurements of the PET ring alone and with the inclusion of the probe data. Images of the Na-22 source demonstrated a resolution of 1.5 mm FWHM in the probe data, the PET ring resolution being approximately 6 mm. Profiles taken through the image of the Derenzo-like phantom showed a clear increase in spatial resolution. Improvements in peak-to-valley ratios of 50% and 38%, in the 4.8 mm and 4.0 mm phantom features respectively, were observed, while previously unresolvable 3.2 mm features were brought to light by the addition of the probe. These results support the possibility of improving the image resolution of a clinical PET scanner using the silicon PET-probe.
van Rossum, Peter S N; Fried, David V; Zhang, Lifei; Hofstetter, Wayne L; van Vulpen, Marco; Meijer, Gert J; Court, Laurence E; Lin, Steven H
2016-05-01
A reliable prediction of a pathologic complete response (pathCR) to chemoradiotherapy before surgery for esophageal cancer would enable investigators to study the feasibility and outcome of an organ-preserving strategy after chemoradiotherapy. So far no clinical parameters or diagnostic studies are able to accurately predict which patients will achieve a pathCR. The aim of this study was to determine whether subjective and quantitative assessment of baseline and postchemoradiation (18)F-FDG PET can improve the accuracy of predicting pathCR to preoperative chemoradiotherapy in esophageal cancer beyond clinical predictors. This retrospective study was approved by the institutional review board, and the need for written informed consent was waived. Clinical parameters along with subjective and quantitative parameters from baseline and postchemoradiation (18)F-FDG PET were derived from 217 esophageal adenocarcinoma patients who underwent chemoradiotherapy followed by surgery. The associations between these parameters and pathCR were studied in univariable and multivariable logistic regression analysis. Four prediction models were constructed and internally validated using bootstrapping to study the incremental predictive values of subjective assessment of (18)F-FDG PET, conventional quantitative metabolic features, and comprehensive (18)F-FDG PET texture/geometry features, respectively. The clinical benefit of (18)F-FDG PET was determined using decision-curve analysis. A pathCR was found in 59 (27%) patients. A clinical prediction model (corrected c-index, 0.67) was improved by adding (18)F-FDG PET-based subjective assessment of response (corrected c-index, 0.72). This latter model was slightly improved by the addition of 1 conventional quantitative metabolic feature only (i.e., postchemoradiation total lesion glycolysis; corrected c-index, 0.73), and even more by subsequently adding 4 comprehensive (18)F-FDG PET texture/geometry features (corrected c-index, 0.77). However, at a decision threshold of 0.9 or higher, representing a clinically relevant predictive value for pathCR at which one may be willing to omit surgery, there was no clear incremental value. Subjective and quantitative assessment of (18)F-FDG PET provides statistical incremental value for predicting pathCR after preoperative chemoradiotherapy in esophageal cancer. However, the discriminatory improvement beyond clinical predictors does not translate into a clinically relevant benefit that could change decision making. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
How Accurate is Land/Ocean Moisture Transport Variability in Reanalyses?
NASA Technical Reports Server (NTRS)
Robertson, F. R.; Bosilovich, M. G.
2014-01-01
Quantifying the global hydrological cycle and its variability across various time scales remains a challenge to the climate community. Direct measurements of evaporation (E), evapotranspiration (ET), and precipitation (P) are not feasible on a global scale, nor is the transport of water vapor over the global oceans and sparsely populated land areas. Expanding satellite data streams have enabled development of various water (and energy) flux products, complementing reanalyses and facilitating observationally constrained modeling. But the evolution of the global observing system has produced additional complications--improvements in satellite sensor resolution and accuracy have resulted in "epochs" of observational quasi-uniformity that can adversely affect reanalysis trends. In this work we focus on vertically integrated moisture flux convergence (VMFC) variations within the period 1979 - present integrated over global land. We show that VMFC in recent reanalyses (e.g. ERA-I, NASA MERRA, NOAA CFSR and JRA55) suffers from observing system changes, though differently in each product. Land Surface Models (LSMs) forced with observations-based precipitation, radiation and near-surface meteorology share closely the interannual P-ET variations of the reanalyses associated with ENSO events. (VMFC over land and P-ET estimates are equivalent quantities since atmospheric storage changes are small on these scales.) But the long-term LSM trend over the period since 1979 is approximately one-fourth that of the reanalyses. Additional reduced observation reanalyses assimilating only surface pressure and /or specifying seasurface temperature also have a much smaller trend in P-ET like the LSMs. We explore the regional manifestation of the reanalysis P-ET / VMFC problems, particularly over land. Both principal component analysis and a simple time series changepoint analysis highlight problems associated with data poor regions such as Equatorial Africa and, for one reanalysis, the Equatorial Andes region. Onset of the availability of passive microwave Special Sensor Microwave Imager (SSMI) moisture data in July 1987 and the transition from the Microwave Sounder Unit (MSU) to an advanced version (AMSU) have significant impacts on VMFC variability. Simple accounting for these errors of leading importance results in modified reanalysis VMFC estimates that agree much better with the LSM results. Regional details of the modified reanalysis VMFC and LSM P-ET are related to changes in Pacific Decadal Variability as manifest in SST changes after the late 1990s.
Courtois, Audrey; Nusgens, Betty V; Hustinx, Roland; Namur, Gauthier; Gomez, Pierre; Somja, Joan; Defraigne, Jean-Olivier; Delvenne, Philippe; Michel, Jean-Baptiste; Colige, Alain C; Sakalihasan, Natzi
2013-10-01
Rupture of abdominal aortic aneurysms (AAAs) leads to a significant morbidity and mortality in aging populations, and its prediction would be most beneficial to public health. Spots positive for uptake of (18)F-FDG detected by PET are found in 12% of AAA patients (PET+), who are most often symptomatic and at high rupture risk. Comparing the (18)F-FDG-positive site with a negative site from the same aneurysm and with samples collected from AAA patients with no (18)F-FDG uptake should allow the discrimination of biologic alterations that would help in identifying markers predictive of rupture. Biopsies of the AAA wall were obtained from patients with no (18)F-FDG uptake (PET0, n = 10) and from PET+ patients (n = 8), both at the site positive for uptake and at a distant negative site of the aneurysmal wall. Samples were analyzed by immunohistochemistry, quantitative real-time polymerase chain reaction, and zymography. The sites of the aneurysmal wall with a positive (18)F-FDG uptake were characterized by a strikingly increased number of adventitial inflammatory cells, highly proliferative, and by a drastic reduction of smooth muscle cells (SMCs) in the media as compared with their negative counterpart and with the PET0 wall. The expression of a series of genes involved in the maintenance and remodeling of the wall was significantly modified in the negative sites of PET+, compared with the PET0 wall, suggesting a systemic alteration of the aneurysmal wall. Furthermore, a striking increase of several matrix metalloproteinases (MMPs), notably the MMP1 and MMP13 collagenases, was observed in the positive sites, mainly in the adventitia. Moreover, PET+ patients were characterized by a higher circulating C-reactive protein. Positive (18)F-FDG uptake in the aneurysmal wall is associated with an active inflammatory process characterized by a dense infiltrate of proliferating leukocytes in the adventitia and an increased circulating C-reactive protein. Moreover, a loss of SMC in the media and alterations of the expression of genes involved in the remodeling of adventitia and collagen degradation potentially participate in the weakening of the aneurysmal wall preceding rupture.
Sabbagh, Marwan N.; Fleisher, Adam; Chen, Kewei; Rogers, Joseph; Berk, Camryn; Reiman, Eric; Pontecorvo, Michael; Mintun, Mark; Skovronsky, Daniel; Jacobson, Sandra A.; Sue, Lucia I.; Liebsack, Carolyn; Charney, Albert S.; Cole, Lauren; Belden, Christine; Beach, Thomas G.
2012-01-01
Background Down syndrome appears to be associated with a virtually certain risk of fibrillar amyloid-β (Aβ) pathology by the age of 40 and a very high risk of dementia at older ages. The positron emission tomography (PET) ligand florbetapir F18 has been shown to characterize fibrillar Aβ in the living human brain and to provide a close correlation with subsequent Aβ neuropathology in individuals proximate to and after the end of life. The extent to which the most frequently used PET ligands can be used to detect fibrillar Aβ in patients with Down syndrome remains to be determined. Objectives To characterize PET estimates of fibrillar Aβ burden in a Down syndrome patient very close to the end of life and to compare them with neuropathologic assessment made after his death. Design/Methods With the family’s informed consent, florbetapir PET was used to study a 55-year-old Down syndrome patient with Alzheimer disease near the end of life; his brain was donated for neuropathologic assessment when he died 14 days later. Visual ratings of cerebral florbetapir uptake were performed by trained readers who were masked to the patient’s diagnosis as part of a larger study, and an automated algorithm was used to characterize regional-to-cerebellar standard uptake value ratios in 6 cerebral regions of interest. Neuropathologic assessments were performed masked to the patient’s diagnosis or PET measurements. Results Visual ratings and automated analyses of the PET image revealed a heavy fibrillar Aβ burden in cortical, striatal, and thalamic regions, similar to that reported for patients with late-onset Alzheimer disease. This matched neuropathologic findings of frequent neuritic and diffuse plaques, as well as frequent amyloid angiopathy, except for neuropathologically demonstrated frequent cerebellar diffuse plaques and amyloid angiopathy that were not detected by the PET scan. Conclusions Florbetapir PET can be used to detect increased cerebral-to-cerebellar fibrillar Aβ burden in a Down syndrome patient with Alzheimer disease, even in the presence of frequent amyloid angiopathy and diffuse plaques in the cerebellum. Additional studies are needed to determine the extent to which PET could be used to detect and to track fibrillar Aβ and to evaluate investigational Aβ-modifying treatments in the presymptomatic and symptomatic stages of Alzheimer disease. PMID:22084131
Rundo, Leonardo; Stefano, Alessandro; Militello, Carmelo; Russo, Giorgio; Sabini, Maria Gabriella; D'Arrigo, Corrado; Marletta, Francesco; Ippolito, Massimo; Mauri, Giancarlo; Vitabile, Salvatore; Gilardi, Maria Carla
2017-06-01
Nowadays, clinical practice in Gamma Knife treatments is generally based on MRI anatomical information alone. However, the joint use of MRI and PET images can be useful for considering both anatomical and metabolic information about the lesion to be treated. In this paper we present a co-segmentation method to integrate the segmented Biological Target Volume (BTV), using [ 11 C]-Methionine-PET (MET-PET) images, and the segmented Gross Target Volume (GTV), on the respective co-registered MR images. The resulting volume gives enhanced brain tumor information to be used in stereotactic neuro-radiosurgery treatment planning. GTV often does not match entirely with BTV, which provides metabolic information about brain lesions. For this reason, PET imaging is valuable and it could be used to provide complementary information useful for treatment planning. In this way, BTV can be used to modify GTV, enhancing Clinical Target Volume (CTV) delineation. A novel fully automatic multimodal PET/MRI segmentation method for Leksell Gamma Knife ® treatments is proposed. This approach improves and combines two computer-assisted and operator-independent single modality methods, previously developed and validated, to segment BTV and GTV from PET and MR images, respectively. In addition, the GTV is utilized to combine the superior contrast of PET images with the higher spatial resolution of MRI, obtaining a new BTV, called BTV MRI . A total of 19 brain metastatic tumors, undergone stereotactic neuro-radiosurgery, were retrospectively analyzed. A framework for the evaluation of multimodal PET/MRI segmentation is also presented. Overlap-based and spatial distance-based metrics were considered to quantify similarity concerning PET and MRI segmentation approaches. Statistics was also included to measure correlation among the different segmentation processes. Since it is not possible to define a gold-standard CTV according to both MRI and PET images without treatment response assessment, the feasibility and the clinical value of BTV integration in Gamma Knife treatment planning were considered. Therefore, a qualitative evaluation was carried out by three experienced clinicians. The achieved experimental results showed that GTV and BTV segmentations are statistically correlated (Spearman's rank correlation coefficient: 0.898) but they have low similarity degree (average Dice Similarity Coefficient: 61.87 ± 14.64). Therefore, volume measurements as well as evaluation metrics values demonstrated that MRI and PET convey different but complementary imaging information. GTV and BTV could be combined to enhance treatment planning. In more than 50% of cases the CTV was strongly or moderately conditioned by metabolic imaging. Especially, BTV MRI enhanced the CTV more accurately than BTV in 25% of cases. The proposed fully automatic multimodal PET/MRI segmentation method is a valid operator-independent methodology helping the clinicians to define a CTV that includes both metabolic and morphologic information. BTV MRI and GTV should be considered for a comprehensive treatment planning. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Matsumura, H.; Toyoda, A.; Masumoto, K.; Yoshida, G.; Yagishita, T.; Nakabayashi, T.; Sasaki, H.; Matsumura, K.; Yamaya, Y.; Miyazaki, Y.
2018-06-01
In the decommissioning work for concrete walls of PET-cyclotron rooms, an in-situ measurement is expected to be useful for obtaining a contour map of the specific activity on the walls without destroying the structure. In this study, specific activities of γ-ray-emitting radionuclides in concrete walls were determined by using an in-situ measurement method employing a portable Ge semiconductor detector, and compared with the specific activity obtained using the sampling measurement method, at the Medical and Pharmacological Research Center Foundation in Hakui, Ishikawa, Japan. Accordingly, the specific activity could be determined by the in-situ determination method. Since there is a clear correlation between the total specific activity of γ-ray-emitting radionuclides and contact dose rate, the specific activity can be determined approximately by contact dose-rate measurement using a NaI scintillation survey meter. The specific activity of each γ-ray-emitting radionuclide can also be estimated from the contact dose rate using a NaI scintillation survey meter. The in-situ measurement method is a powerful tool for the decommissioning of the PET cyclotron room.
Elmaleh, D R; Fischman, A J; Tawakol, A; Zhu, A; Shoup, T M; Hoffmann, U; Brownell, A-L; Zamecnik, P C
2006-10-24
Diadenosine-5',5'''-P(1),P(4)-tetraphosphate (Ap(4)A) and its analog P(2),P(3)-monochloromethylene diadenosine-5',5'''-P(1),P(4)-tetraphosphate (AppCHClppA) are competitive inhibitors of adenosine diphosphate-induced platelet aggregation, which plays a central role in arterial thrombosis and plaque formation. In this study, we evaluate the imaging capabilities of positron-emission tomography (PET) with P(2),P(3)-[(18)F]monofluoromethylene diadenosine-5',5'''-P(1),P(4)-tetraphosphate ([(18)F]AppCHFppA) to detect atherosclerotic lesions in male New Zealand White rabbits. Three to six months after balloon injury to the aorta, the rabbits were injected with [(18)F]AppCHFppA, and microPET imaging showed rapid accumulation of this radiopharmaceutical in the atherosclerotic abdominal aorta, with lesions clearly visible 30 min after injection. Computed tomographic images were coregistered with PET images to improve delineation of aortoiliac tracer activity. Plaque macrophage density, quantified by immunostaining with RAM11 against rabbit macrophages, correlated with PET measurements of [(18)F]AppCHFppA uptake (r = 0.87, P < 0.0001), whereas smooth-muscle cell density, quantified by immunostaining with 1A4 against smooth muscle actin, did not. Biodistribution studies of [(18)F]AppCHFppA in normal rats indicated typical adenosine dinucleotide behavior with insignificant myocardial uptake and fast kidney clearance. The accumulation of [(18)F]AppCHFppA in macrophage-rich atherosclerotic plaques can be quantified noninvasively with PET. Hence, [(18)F]AppCHFppA holds promise for the noninvasive characterization of vascular inflammation.
The amyloid cascade-inflammatory hypothesis of Alzheimer disease: implications for therapy.
McGeer, Patrick L; McGeer, Edith G
2013-10-01
The amyloid cascade hypothesis is widely accepted as the centerpiece of Alzheimer disease (AD) pathogenesis. It proposes that abnormal production of beta amyloid protein (Abeta) is the cause of AD and that the neurotoxicity is due to Abeta itself or its oligomeric forms. We suggest that this, in itself, cannot be the cause of AD because demonstrating such toxicity requires micromolar concentrations of these Abeta forms, while their levels in brain are a million times lower in the picomolar range. AD probably results from the inflammatory response induced by extracellular Abeta deposits, which later become enhanced by aggregates of tau. The inflammatory response, which is driven by activated microglia, increases over time as the disease progresses. Disease-modifying therapeutic attempts to date have failed and may continue to do so as long as the central role of inflammation is not taken into account. Multiple epidemiological and animal model studies show that NSAIDs, the most widely used antiinflammatory agents, have a substantial sparing effect on AD. These studies provide a proof of concept regarding the anti-inflammatory approach to disease modification. Biomarker studies have indicated that early intervention may be necessary. They have established that disease onset occurs more than a decade before it becomes clinically evident. By combining biomarker and pathological data, it is possible to define six phases of disease development, each separated by about 5 years. Phase one can be identified by decreases in Abeta in the CSF, phase 2 by increases of tau in the CSF plus clear evidence of Abeta brain deposits by PET scanning, phase 3 by slight decreases in brain metabolic rate by PET-FDG scanning, phase 4 by slight decreases in brain volume by MRI scanning plus minimal cognitive impairment, phase 5 by increased scanning abnormalities plus clinical diagnosis of AD, and phase 6 by advanced AD requiring institutional care. Utilization of antiinflammatory agents early in the disease process remains an overlooked therapeutic opportunity. Such agents, while not preventative, have the advantage of being able to inhibit the consequences of both Abeta and tau aggregation. Since there is more than a decade between disease onset and cognitive decline, a window of opportunity exists to introduce truly effective disease-modifying regimens. Taking advantage of this opportunity is the challenge for the future.
NASA Astrophysics Data System (ADS)
Lim, Hongki; Dewaraja, Yuni K.; Fessler, Jeffrey A.
2018-02-01
Most existing PET image reconstruction methods impose a nonnegativity constraint in the image domain that is natural physically, but can lead to biased reconstructions. This bias is particularly problematic for Y-90 PET because of the low probability positron production and high random coincidence fraction. This paper investigates a new PET reconstruction formulation that enforces nonnegativity of the projections instead of the voxel values. This formulation allows some negative voxel values, thereby potentially reducing bias. Unlike the previously reported NEG-ML approach that modifies the Poisson log-likelihood to allow negative values, the new formulation retains the classical Poisson statistical model. To relax the non-negativity constraint embedded in the standard methods for PET reconstruction, we used an alternating direction method of multipliers (ADMM). Because choice of ADMM parameters can greatly influence convergence rate, we applied an automatic parameter selection method to improve the convergence speed. We investigated the methods using lung to liver slices of XCAT phantom. We simulated low true coincidence count-rates with high random fractions corresponding to the typical values from patient imaging in Y-90 microsphere radioembolization. We compared our new methods with standard reconstruction algorithms and NEG-ML and a regularized version thereof. Both our new method and NEG-ML allow more accurate quantification in all volumes of interest while yielding lower noise than the standard method. The performance of NEG-ML can degrade when its user-defined parameter is tuned poorly, while the proposed algorithm is robust to any count level without requiring parameter tuning.
2015-01-01
Using positron emission tomography (PET) imaging to monitor and quantitatively analyze the delivery and localization of Au nanomaterials (NMs), a widely used photothermal agent, is essential to optimize therapeutic protocols to achieve individualized medicine and avoid side effects. Coupling radiometals to Au NMs via a chelator faces the challenges of possible detachment of the radiometals as well as surface property changes of the NMs. In this study, we reported a simple and general chelator-free 64Cu radiolabeling method by chemically reducing 64Cu on the surface of polyethylene glycol (PEG)-stabilized Au NMs regardless of their shape and size. Our 64Cu-integrated NMs are proved to be radiochemically stable and can provide an accurate and sensitive localization of NMs through noninvasive PET imaging. We further integrated 64Cu onto arginine-glycine-aspartic acid (RGD) peptide modified Au nanorods (NRs) for tumor theranostic application. These NRs showed high tumor targeting ability in a U87MG glioblastoma xenograft model and were successfully used for PET image-guided photothermal therapy. PMID:25019252
NASA Astrophysics Data System (ADS)
Niu, Xiaofeng; Ye, Hongwei; Xia, Ting; Asma, Evren; Winkler, Mark; Gagnon, Daniel; Wang, Wenli
2015-07-01
Quantitative PET imaging is widely used in clinical diagnosis in oncology and neuroimaging. Accurate normalization correction for the efficiency of each line-of- response is essential for accurate quantitative PET image reconstruction. In this paper, we propose a normalization calibration method by using the delayed-window coincidence events from the scanning phantom or patient. The proposed method could dramatically reduce the ‘ring’ artifacts caused by mismatched system count-rates between the calibration and phantom/patient datasets. Moreover, a modified algorithm for mean detector efficiency estimation is proposed, which could generate crystal efficiency maps with more uniform variance. Both phantom and real patient datasets are used for evaluation. The results show that the proposed method could lead to better uniformity in reconstructed images by removing ring artifacts, and more uniform axial variance profiles, especially around the axial edge slices of the scanner. The proposed method also has the potential benefit to simplify the normalization calibration procedure, since the calibration can be performed using the on-the-fly acquired delayed-window dataset.
The National Asthma Campaign Manchester Asthma and Allergy Study.
Custovic, Adnan; Simpson, Bridget M; Murray, Clare S; Lowe, Lesley; Woodcock, Ashley
2002-01-01
The NACManchester Asthma and Allergy Study is a prospective study of the development of asthma and allergies in childhood. The subjects (995 children at age 3 years) were recruited in utero by screening parents in the antenatal clinic using skin prick testing and a questionnaire regarding allergic diseases. Children were assigned to risk groups according to parental atopic status (high risk, both parents atopic; medium risk, one parent atopic; low risk, neither parent atopic). A subgroup of those at high risk (with no pets in the home) was randomized to stringent environmental control (allergen impermeable covers for the parental and infant bed, hot washing of bedding weekly, HEPA vacuum cleaner, hard floor for the nursery), and the remainder followed a normal regime. The children have been followed prospectively. The environmental influences are very clearly defined. Measurements of environmental exposures include levels of house dust mite; cat and dog allergens during pregnancy and early life; pet ownership and exposure; childcare arrangements; number of siblings; vaccination uptake; thorough dietary questionnaire; and endotoxin exposure. Further unique objective outcome in the cohort is the assessment of lung function in preschool children using specific airways resistance, which at age 3 years clearly reflects both genetic and environmental influences.
Effect of Cognitive Reserve Markers on Alzheimer Pathological Progression
Lo, Raymond Y.; Jagust, William J.
2013-01-01
Education, occupation, premorbid intelligence and brain size are surrogate markers for cognitive reserve. Whether these markers have biological influence on Alzheimer disease (AD) pathology is not known. We thus aimed to investigate the effect of cognitive reserve proxies on longitudinal change of AD biomarkers. A total of 819 participants with normal cognition (NC), mild cognitive impairment (MCI) and mild AD were enrolled in the Alzheimer’s Disease Neuroimaging Initiative and followed up with repeated measures of CSF, PET and MRI biomarkers. Generalized estimating equations were employed to assess whether biomarker rates of change were modified by reserve proxies. CSF Aβ42 decline was slower in NC participants with higher cognitive reserve indexed by education, occupation and American National Adult Reading Test (ANART). The decline of [18F] fluorodeoxyglucose PET uptake was slower in AD participants with better performance on the ANART. Education, occupation and ANART did not modify the rates of MRI hippocampal atrophy in any group. These findings remained unchanged after accounting for APOE 4, longitudinal missing data and baseline cognitive performance. Higher levels of reserve markers may slow the rate of amyloid deposition before cognitive impairment and preserve glucose metabolism at the dementia stage over the course of AD pathological progression. PMID:23552443
Molecular Identification of Cryptosporidium Species from Pet Snakes in Thailand.
Yimming, Benjarat; Pattanatanang, Khampee; Sanyathitiseree, Pornchai; Inpankaew, Tawin; Kamyingkird, Ketsarin; Pinyopanuwat, Nongnuch; Chimnoi, Wissanuwat; Phasuk, Jumnongjit
2016-08-01
Cryptosporidium is an important pathogen causing gastrointestinal disease in snakes and is distributed worldwide. The main objectives of this study were to detect and identify Cryptosporidium species in captive snakes from exotic pet shops and snake farms in Thailand. In total, 165 fecal samples were examined from 8 snake species, boa constrictor (Boa constrictor constrictor), corn snake (Elaphe guttata), ball python (Python regius), milk snake (Lampropeltis triangulum), king snake (Lampropeltis getula), rock python (Python sebae), rainbow boa (Epicrates cenchria), and carpet python (Morelia spilota). Cryptosporidium oocysts were examined using the dimethyl sulfoxide (DMSO)-modified acid-fast staining and a molecular method based on nested-PCR, PCR-RFLP analysis, and sequencing amplification of the SSU rRNA gene. DMSO-modified acid-fast staining revealed the presence of Cryptosporidium oocysts in 12 out of 165 (7.3%) samples, whereas PCR produced positive results in 40 (24.2%) samples. Molecular characterization indicated the presence of Cryptosporidium parvum (mouse genotype) as the most common species in 24 samples (60%) from 5 species of snake followed by Cryptosporidium serpentis in 9 samples (22.5%) from 2 species of snake and Cryptosporidium muris in 3 samples (7.5%) from P. regius.
Molecular Identification of Cryptosporidium Species from Pet Snakes in Thailand
Yimming, Benjarat; Pattanatanang, Khampee; Sanyathitiseree, Pornchai; Inpankaew, Tawin; Kamyingkird, Ketsarin; Pinyopanuwat, Nongnuch; Chimnoi, Wissanuwat; Phasuk, Jumnongjit
2016-01-01
Cryptosporidium is an important pathogen causing gastrointestinal disease in snakes and is distributed worldwide. The main objectives of this study were to detect and identify Cryptosporidium species in captive snakes from exotic pet shops and snake farms in Thailand. In total, 165 fecal samples were examined from 8 snake species, boa constrictor (Boa constrictor constrictor), corn snake (Elaphe guttata), ball python (Python regius), milk snake (Lampropeltis triangulum), king snake (Lampropeltis getula), rock python (Python sebae), rainbow boa (Epicrates cenchria), and carpet python (Morelia spilota). Cryptosporidium oocysts were examined using the dimethyl sulfoxide (DMSO)-modified acid-fast staining and a molecular method based on nested-PCR, PCR-RFLP analysis, and sequencing amplification of the SSU rRNA gene. DMSO-modified acid-fast staining revealed the presence of Cryptosporidium oocysts in 12 out of 165 (7.3%) samples, whereas PCR produced positive results in 40 (24.2%) samples. Molecular characterization indicated the presence of Cryptosporidium parvum (mouse genotype) as the most common species in 24 samples (60%) from 5 species of snake followed by Cryptosporidium serpentis in 9 samples (22.5%) from 2 species of snake and Cryptosporidium muris in 3 samples (7.5%) from P. regius. PMID:27658593
Physical and clinical performance of the mCT time-of-flight PET/CT scanner.
Jakoby, B W; Bercier, Y; Conti, M; Casey, M E; Bendriem, B; Townsend, D W
2011-04-21
Time-of-flight (TOF) measurement capability promises to improve PET image quality. We characterized the physical and clinical PET performance of the first Biograph mCT TOF PET/CT scanner (Siemens Medical Solutions USA, Inc.) in comparison with its predecessor, the Biograph TruePoint TrueV. In particular, we defined the improvements with TOF. The physical performance was evaluated according to the National Electrical Manufacturers Association (NEMA) NU 2-2007 standard with additional measurements to specifically address the TOF capability. Patient data were analyzed to obtain the clinical performance of the scanner. As expected for the same size crystal detectors, a similar spatial resolution was measured on the mCT as on the TruePoint TrueV. The mCT demonstrated modestly higher sensitivity (increase by 19.7 ± 2.8%) and peak noise equivalent count rate (NECR) (increase by 15.5 ± 5.7%) with similar scatter fractions. The energy, time and spatial resolutions for a varying single count rate of up to 55 Mcps resulted in 11.5 ± 0.2% (FWHM), 527.5 ± 4.9 ps (FWHM) and 4.1 ± 0.0 mm (FWHM), respectively. With the addition of TOF, the mCT also produced substantially higher image contrast recovery and signal-to-noise ratios in a clinically-relevant phantom geometry. The benefits of TOF were clearly demonstrated in representative patient images.
NASA Astrophysics Data System (ADS)
Preziosi, E.; Sánchez, S.; González, A. J.; Pani, R.; Borrazzo, C.; Bettiol, M.; Rodriguez-Alvarez, M. J.; González-Montoro, A.; Moliner, L.; Benlloch, J. M.
2016-12-01
One of the technical objectives of the MindView project is developing a brain-dedicated PET insert based on monolithic scintillation crystals. It will be inserted in MRI systems with the purpose to obtain simultaneous PET and MRI brain images. High sensitivity, high image quality performance and accurate detection of the Depth-of-Interaction (DoI) of the 511keV photons are required. We have developed a DoI estimation method, dedicated to monolithic scintillators, allowing continuous DoI estimation and a DoI-dependent algorithm for the estimation of the photon planar impact position, able to improve the single module imaging capabilities. In this work, through experimental measurements, the proposed methods have been used for the estimation of the impact positions within the monolithic crystal block. We have evaluated the PET system performance following the NEMA NU 4-2008 protocol by reconstructing the images using the STIR 3D platform. The results obtained with two different methods, providing discrete and continuous DoI information, are compared with those obtained from an algorithm without DoI capabilities and with the ideal response of the detector. The proposed DoI-dependent imaging methods show clear improvements in the spatial resolution (FWHM) of reconstructed images, allowing to obtain values from 2mm (at the center FoV) to 3mm (at the FoV edges).
Comparison Study of Two Differently Clicked 18F-Folates—Lipophilicity Plays a Key Role
Kettenbach, Kathrin; Reffert, Laura M.; Schieferstein, Hanno; Pektor, Stefanie; Eckert, Raphael; Miederer, Matthias; Rösch, Frank
2018-01-01
Within the last decade, several folate-based radiopharmaceuticals for Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) have been evaluated; however, there is still a lack of suitable 18F-folates for clinical PET imaging. Herein, we report the synthesis and evaluation of two novel 18F-folates employing strain-promoted and copper-catalyzed click chemistry. Furthermore, the influence of both click-methods on lipophilicity and pharmacokinetics of the 18F-folates was investigated. 18F-Ala-folate and 18F-DBCO-folate were both stable in human serum albumin. In vitro studies proved their high affinity to the folate receptor (FR). The lipophilic character of the strain-promoted clicked 18F-DBCO-folate (logD = 0.6) contributed to a higher non-specific binding in cell internalization studies. In the following in vivo PET imaging studies, FR-positive tumors could not be visualized in a maximum intensity projection images. Compared with 18F-DBCO-folate, 18F-Ala-folate (logD = −1.4), synthesized by the copper-catalyzed click reaction, exhibited reduced lipophilicity, and as a result an improved in vivo performance and a clear-cut visualization of FR-positive tumors. In view of high radiochemical yield, radiochemical purity and favorable pharmacokinetics, 18F-Ala-folate is expected to be a promising candidate for FR-PET imaging. PMID:29562610
Physical and clinical performance of the mCT time-of-flight PET/CT scanner
NASA Astrophysics Data System (ADS)
Jakoby, B. W.; Bercier, Y.; Conti, M.; Casey, M. E.; Bendriem, B.; Townsend, D. W.
2011-04-01
Time-of-flight (TOF) measurement capability promises to improve PET image quality. We characterized the physical and clinical PET performance of the first Biograph mCT TOF PET/CT scanner (Siemens Medical Solutions USA, Inc.) in comparison with its predecessor, the Biograph TruePoint TrueV. In particular, we defined the improvements with TOF. The physical performance was evaluated according to the National Electrical Manufacturers Association (NEMA) NU 2-2007 standard with additional measurements to specifically address the TOF capability. Patient data were analyzed to obtain the clinical performance of the scanner. As expected for the same size crystal detectors, a similar spatial resolution was measured on the mCT as on the TruePoint TrueV. The mCT demonstrated modestly higher sensitivity (increase by 19.7 ± 2.8%) and peak noise equivalent count rate (NECR) (increase by 15.5 ± 5.7%) with similar scatter fractions. The energy, time and spatial resolutions for a varying single count rate of up to 55 Mcps resulted in 11.5 ± 0.2% (FWHM), 527.5 ± 4.9 ps (FWHM) and 4.1 ± 0.0 mm (FWHM), respectively. With the addition of TOF, the mCT also produced substantially higher image contrast recovery and signal-to-noise ratios in a clinically-relevant phantom geometry. The benefits of TOF were clearly demonstrated in representative patient images.
Electrical properties of double layer dielectric structures for space technology
NASA Astrophysics Data System (ADS)
Lian, Anqing
1993-04-01
Polymeric films such as polyimide (PI) and polyethylene terephthalate (PET) are used in space technology as thermal blankets. Thin SiO2 and SiN coatings plasma deposited onto PI and PET surfaces were proposed to protect the blanket materials against the space environment. The electrical properties of this kind of dual layer dielectric structure were investigated to understand the mechanisms for suppressing charge accumulation and flashover. Bulk and surface electrical conductivities of thin single-layer PI and PET samples and of the dual layer SiO2 and SiN combinations with PI and PET were measured in a range of applied electrical fields. The capacitance voltage (CV) technique was used for analyzing charge transport and distribution in the structures. The electric current in the bulk of the SiO2/PI and SiN/PI samples was found to depend on the polarity of the electric field. Other samples did not exhibit any such polarity effect. The polarity dependence is attributed to charge trapping at the PI/plasma deposit interface. The CV characteristics of the Al-PI-SiO2-Si structure confirm that charges which can modify the local electric field can be trapped near the interface. A model is proposed to interpret the properties of the currents in dual layer structures. This model can semi-quantitatively explain all the observed results.
Tauzin, Tibor; Csík, Andor; Lovas, Kata; Gergely, György; Topál, József
2017-02-01
Both human infants and nonhuman primates can recognize unfamiliar entities as instrumental agents ascribing to them goals and efficiency of goal-pursuit. This competence relies on movement cues indicating distal sensitivity to the environment and choice of efficient goal-approach. Although dogs' evolved sensitivity to social cues allow them to recognize humans as communicative agents, it remains unclear whether they have also evolved a basic concept of instrumental agency. We used a preferential object-choice procedure to test whether adult pet dogs and human toddlers can identify unfamiliar entities as agents based on different types of movement cues that specify different levels of agency. In the navigational agency condition, dogs preferentially chose an object that modified its pathway to avoid collision with obstacles over another object showing no evidence of distal sensitivity (regularly bumping into obstacles). However, in the goal-efficiency condition where neither object collided with obstacles as it navigated toward a distal target, but only 1 of them exhibited efficient goal-approach as well, toddlers, but not dogs, showed a preference toward the efficient goal-directed agent. These findings indicate that dogs possess a limited concept of environmentally sensitive navigational agency that they attribute to self-propelled entities capable of modifying their movement to avoid colliding with obstacles. Toddlers, in contrast, demonstrated clear sensitivity to cues of efficient variability of goal-approach as the basis for differentiating, attributing, and showing preference for goal-directed instrumental agency. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Farolfi, Andrea; Ceci, Francesco; Castellucci, Paolo; Graziani, Tiziano; Siepe, Giambattista; Lambertini, Alessandro; Schiavina, Riccardo; Lodi, Filippo; Morganti, Alessio G; Fanti, Stefano
2018-06-15
The primary aim of this retrospective, single-centre analysis was to assess the performance of 68 Ga-PSMA-11 PET/CT in prostate cancer (PCa) patients in early PSA failure after radical prostatectomy (RP). The secondary aim was to assess the potential impact of 68 Ga-PSMA-11 PET/CT on treatment strategy. 68 Ga-PSMA-11 PET/CT is performed in our institution within an investigational new drug (IND) trial in PCa patients with biochemical recurrence (BCR). The records of all patients enrolled between March 2016 and July 2017 were evaluated. These records were retrospectively analysed according to the following inclusion criteria: (a) RP as primary therapy, (b) proven BCR, ©) PSA levels in the range 0.2-0.5 ng/ml at the time of the 68 Ga-PSMA-11 PET/CT investigation, and (d) no salvage radiotherapy (S-RT) performed after recurrence. The performance of 68 Ga-PSMA-11 PET/CT was evaluated in terms of detection rate on a per-patient and a per-region basis (local vs. distant lesions). We further performed an intention-to-treat (ITT) analysis. The patient cohort was grouped into three subpopulations, blinded to the 68 Ga-PSMA-11 PET/CT results, according to the patients' characteristics and different patterns of treatment: (1) S-RT (with or without systemic treatment), (2) stereotactic body radiotherapy (SBRT) (with or without systemic treatment), and (3) systemic treatment. The treatment strategy was re-evaluated for each patient taking into consideration the 68 Ga-PSMA-11 PET/CT images. We enrolled 119 PCa patients (mean age 66 years, range 44-78 years) with a mean PSA level at the time of 68 Ga-PSMA-11 PET/CT of 0.34 ng/ml (median 0.32 ng/ml, SD ±0.09, range 0.20-0.50 ng/ml). 68 Ga-PSMA-1 1 PET/CT was positive in 41 of the 119 patients, resulting in an overall detection rate of 34.4%. 68 Ga-PSMA-11 uptake was observed in the prostate bed (3 patients, 2.5%), in the pelvic lymph nodes (21, 17.6%), in the retroperitoneal lymph nodes (4, 3.4%) and in the skeleton (21, 17.6%). Regarding ITT, 81 patients (68.1%) were considered possible candidates for S-RT only in the prostate bed and none of the patients (0%) for SBRT. According to the 68 Ga-PSMA-11 PET/CT results, the intended treatment was changed in 36 patients (30.2%). According to the PET/CT results, S-RT was recommended in 70 patients (58.8%), only to the prostate bed in 58 (48.7%) and SBRT in 29 (24.4%). The intended RT planning was modified in 36 (87.8%) of 41 patients with a positive 68 Ga-PSMA-11 PET/CT result. In our patient series with PSA levels <0.5 ng/ml, 68 Ga-PSMA-11 PET/CT had a detection rate of 34.4%. In the ITT analysis, 30.2% of patients had a change in the intended treatment. These data support the hypothesis that 68 Ga-PSMA-11 PET/CT is a useful procedure in the management of PCa patients showing early recurrence after RP, and should be implemented in routine clinical practice.
Anatomy assisted PET image reconstruction incorporating multi-resolution joint entropy
NASA Astrophysics Data System (ADS)
Tang, Jing; Rahmim, Arman
2015-01-01
A promising approach in PET image reconstruction is to incorporate high resolution anatomical information (measured from MR or CT) taking the anato-functional similarity measures such as mutual information or joint entropy (JE) as the prior. These similarity measures only classify voxels based on intensity values, while neglecting structural spatial information. In this work, we developed an anatomy-assisted maximum a posteriori (MAP) reconstruction algorithm wherein the JE measure is supplied by spatial information generated using wavelet multi-resolution analysis. The proposed wavelet-based JE (WJE) MAP algorithm involves calculation of derivatives of the subband JE measures with respect to individual PET image voxel intensities, which we have shown can be computed very similarly to how the inverse wavelet transform is implemented. We performed a simulation study with the BrainWeb phantom creating PET data corresponding to different noise levels. Realistically simulated T1-weighted MR images provided by BrainWeb modeling were applied in the anatomy-assisted reconstruction with the WJE-MAP algorithm and the intensity-only JE-MAP algorithm. Quantitative analysis showed that the WJE-MAP algorithm performed similarly to the JE-MAP algorithm at low noise level in the gray matter (GM) and white matter (WM) regions in terms of noise versus bias tradeoff. When noise increased to medium level in the simulated data, the WJE-MAP algorithm started to surpass the JE-MAP algorithm in the GM region, which is less uniform with smaller isolated structures compared to the WM region. In the high noise level simulation, the WJE-MAP algorithm presented clear improvement over the JE-MAP algorithm in both the GM and WM regions. In addition to the simulation study, we applied the reconstruction algorithms to real patient studies involving DPA-173 PET data and Florbetapir PET data with corresponding T1-MPRAGE MRI images. Compared to the intensity-only JE-MAP algorithm, the WJE-MAP algorithm resulted in comparable regional mean values to those from the maximum likelihood algorithm while reducing noise. Achieving robust performance in various noise-level simulation and patient studies, the WJE-MAP algorithm demonstrates its potential in clinical quantitative PET imaging.
HIGH-RESOLUTION L(Y)SO DETECTORS USING PMT-QUADRANT-SHARING FOR HUMAN & ANIMAL PET CAMERAS
Ramirez, Rocio A.; Liu, Shitao; Liu, Jiguo; Zhang, Yuxuan; Kim, Soonseok; Baghaei, Hossain; Li, Hongdi; Wang, Yu; Wong, Wai-Hoi
2009-01-01
We developed high resolution L(Y)SO detectors for human and animal PET applications using Photomultiplier-quadrant-sharing (PQS) technology. The crystal sizes were 1.27 × 1.27 × 10 mm3 for the animal PQS-blocks and 3.25 × 3.25 × 20 mm3 for human ones. Polymer mirror film patterns (PMR) were placed between crystals as reflector. The blocks were assembled together using optical grease and wrapped by Teflon tape. The blocks were coupled to regular round PMT’s of 19/51 mm in PQS configuration. List-mode data of Ga-68 source (511 KeV) were acquired with our high yield pileup-event recovery (HYPER) electronics and data acquisition software. The high voltage bias was 1100V. Crystal decoding maps and individual crystal energy resolutions were extracted from the data. To investigate the potential imaging resolution of the PET cameras with these blocks, we used GATE (Geant4 Application for Tomographic Emission) simulation package. GATE is a GEANT4 based software toolkit for realistic simulation of PET and SPECT systems. The packing fractions of these blocks were found to be 95.6% and 98.2%. From the decoding maps, all 196 and 225 crystals were clearly identified. The average energy resolutions were 14.0% and 15.6%. For small animal PET systems, the detector ring diameter was 16.5 cm with an axial field of view (AFOV) of 11.8 cm. The simulation data suggests that a reconstructed radial (tangential) spatial resolution of 1.24 (1.25) mm near the center is potentially achievable. For the wholebody human PET systems, the detector ring diameter was 86 cm. The simulation data suggests that a reconstructed radial (tangential) spatial resolution of 3.09(3.38) mm near the center is potentially achievable. From this study we can conclude that PQS design could achieve high spatial resolutions and excellent energy resolutions on human and animal PET systems with substantially lower production costs and inexpensive readout devices. PMID:19946463
TH-EF-207A-02: Imaging Pancreatic Î{sup 2}-Cell Function with 51/52Mn-PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graves, S; Hernandez, R; England, C
Purpose: To image β-cells noninvasively using radio-manganese PET and to develop efficient small cyclotron production of {sup 51}Mn (t1/2=46m, β{sup +}=97%) and {sup 52}Mn (t1/2=5.6d, β{sup +}=29%). Methods: {sup 51}Mn and {sup 52}Mn were produced by 16 MeV proton irradiation (GE PETtrace) of electrodeposited {sup 54}Fe on silver and Cr metal pressed into a silver disc, respectively. {sup 51}Mn was radiochemically isolated from target material by anion exchange chromatography and {sup 52}Mn was isolated by ethanolic anion exchange trap-and-release. A final injectable product of {sup 51}Mn{sup 2+} or {sup 52}Mn{sup 2+} was obtained in 0.01M pH 6.0 NaOAc. To assessmore » pancreatic uptake, fasted ICR mice were administered and intravenous bolus or infusion of {sup 52}Mn{sup 2+}. Additionally, to demonstrate the correlation between β-cell function and {sup 52}Mn{sup 2+} pancreatic uptake, prior to tracer administration groups of ICR mice were administered glibenclamide (5mg/kg) and diazoxide (20 mg/kg) as an insulin release stimulator and blocker, respectively. To validate PET ROI quantification, ex vivo biodistribtution studies were conducted on each subject after the final imaging time-point. Results: Dynamic PET data using a left atrium ROI revealed that {sup 52}Mn{sup 2+} cleared from the blood with a 10 second half-life. Significant uptake was seen in the pancreas (approximately 20% ID/g, SUVmean= 5.5), liver, kidneys, intestine, heart, and thyroid. Pancreatic uptake was found to be highly sensitive to volatile anesthesia administration (p=0.0002), insulin release stimulation by glibenclamide (p=0.017), and by insulin release inhibition by diazoxide (p=0.046). Excellent agreement was found between in vivo PET ROI quantification and ex vivo biodistribution measurements. Conclusion: This work demonstrates the feasibility of using radiomanganese-PET for measuring functional β-cell mass in vivo. The decay characteristics and dosimetric properties of {sup 51}Mn are well suited for clinical PET, which will allow for rapid translation and application.« less
Yu, Yao; Zhang, Wen-Bo; Liu, Xiao-Jing; Guo, Chuan-Bin; Yu, Guang-Yan; Peng, Xin
2017-06-01
The purpose of this study was to describe new technology assisted by 3-dimensional (3D) image fusion of 18 F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced CT (CECT) for computer planning of a maxillectomy of recurrent maxillary squamous cell carcinoma and defect reconstruction. Treatment of recurrent maxillary squamous cell carcinoma usually includes tumor resection and free flap reconstruction. FDG-PET/CT provided images of regions of abnormal glucose uptake and thus showed metabolic tumor volume to guide tumor resection. CECT data were used to create 3D reconstructed images of vessels to show the vascular diameters and locations, so that the most suitable vein and artery could be selected during anastomosis of the free flap. The data from preoperative maxillofacial CECT scans and FDG-PET/CT imaging were imported into the navigation system (iPlan 3.0; Brainlab, Feldkirchen, Germany). Three-dimensional image fusion between FDG-PET/CT and CECT was accomplished using Brainlab software according to the position of the 2 skulls simulated in the CECT image and PET/CT image, respectively. After verification of the image fusion accuracy, the 3D reconstruction images of the metabolic tumor, vessels, and other critical structures could be visualized within the same coordinate system. These sagittal, coronal, axial, and 3D reconstruction images were used to determine the virtual osteotomy sites and reconstruction plan, which was provided to the surgeon and used for surgical navigation. The average shift of the 3D image fusion between FDG-PET/CT and CECT was less than 1 mm. This technique, by clearly showing the metabolic tumor volume and the most suitable vessels for anastomosis, facilitated resection and reconstruction of recurrent maxillary squamous cell carcinoma. We used 3D image fusion of FDG-PET/CT and CECT to successfully accomplish resection and reconstruction of recurrent maxillary squamous cell carcinoma. This method has the potential to improve the clinical outcomes of these challenging procedures. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
PET imaging of tumor angiogenesis in mice with VEGF-A targeted 86Y-CHX-A″-DTPA-bevacizumab
Nayak, Tapan K.; Garmestani, Kayhan; Baidoo, Kwamena E.; Milenic, Diane E.; Brechbiel, Martin W.
2010-01-01
Bevacizumab is a humanized monoclonal antibody that binds to tumor-secreted VEGF-A and inhibits tumor angiogenesis. In 2004, the antibody was approved by the United States FDA for the treatment of metastatic colorectal carcinoma in combination with chemotherapy. This report describes the preclinical evaluation of a radioimmunoconjugate, 86Y-CHX-A″-DTPA-bevacizumab, for potential use in PET imaging of VEGF-A tumor angiogenesis and as a surrogate marker for 90Y based radioimmunotherapy. Bevacizumab was conjugated to CHX-A″-DTPA and radiolabeled with 86Y. In vivo biodistribution and PET imaging studies were performed on mice bearing VEGF-A secreting human colorectal (LS-174T), human ovarian (SKOV-3) and VEGF-A negative human mesothelioma (MSTO-211H) xenografts. Biodistribution and PET imaging studies demonstrated high specific tumor uptake of the radioimmunoconjugate. In mice bearing VEGF-A secreting LS-174T, SKOV-3 and VEGF-A negative MSTO-211H tumors, the tumor uptake at 3 d post-injection (p.i) was 13.6 ± 1.5, 17.4 ± 1.7 and 6.8 ± 0.7 % ID/g, respectively. The corresponding tumor uptake in mice co-injected with 0.05 mg cold bevacizumab were 5.8 ± 1.3, 8.9 ± 1.9 and 7.4 ± 1.0 % ID/g, respectively at the same time point, demonstrating specific blockage of the target in VEGF-A secreting tumors. The LS-174T and SKOV3 tumors were clearly visualized by PET imaging after injecting 1.8–2.0 MBq 86Y-CHX-A″-DTPA-bevacizumab. Organ uptake quantified by PET closely correlated (r2=0.87, p=0.64, n=18) to values determined by biodistribution studies. This preclinical study demonstrates the potential of the radioimmunoconjugate, 86Y-CHX-A″-DTPA-bevacizumab, for non-invasive assessment of the VEGF-A tumor angiogenesis status and as a surrogate marker for 90Y-CHX-A″-DTPA-bevacizumab radioimmunotherapy. PMID:20473899
NASA Astrophysics Data System (ADS)
Jochimsen, Thies H.; Schulz, Jessica; Busse, Harald; Werner, Peter; Schaudinn, Alexander; Zeisig, Vilia; Kurch, Lars; Seese, Anita; Barthel, Henryk; Sattler, Bernhard; Sabri, Osama
2015-06-01
This study explores the possibility of using simultaneous positron emission tomography—magnetic resonance imaging (PET-MRI) to estimate the lean body mass (LBM) in order to obtain a standardized uptake value (SUV) which is less dependent on the patients' adiposity. This approach is compared to (1) the commonly-used method based on a predictive equation for LBM, and (2) to using an LBM derived from PET-CT data. It is hypothesized that an MRI-based correction of SUV provides a robust method due to the high soft-tissue contrast of MRI. A straightforward approach to calculate an MRI-derived LBM is presented. It is based on the fat and water images computed from the two-point Dixon MRI primarily used for attenuation correction in PET-MRI. From these images, a water fraction was obtained for each voxel. Averaging over the whole body yielded the weight-normalized LBM. Performance of the new approach in terms of reducing variations of 18F-Fludeoxyglucose SUVs in brain and liver across 19 subjects was compared with results using predictive methods and PET-CT data to estimate the LBM. The MRI-based method reduced the coefficient of variation of SUVs in the brain by 41 ± 10% which is comparable to the reduction by the PET-CT method (35 ± 10%). The reduction of the predictive LBM method was 29 ± 8%. In the liver, the reduction was less clear, presumably due to other sources of variation. In conclusion, employing the Dixon data in simultaneous PET-MRI for calculation of lean body mass provides a brain SUV which is less dependent on patient adiposity. The reduced dependency is comparable to that obtained by CT and predictive equations. Therefore, it is more comparable across patients. The technique does not impose an overhead in measurement time and is straightforward to implement.
Jochimsen, Thies H; Schulz, Jessica; Busse, Harald; Werner, Peter; Schaudinn, Alexander; Zeisig, Vilia; Kurch, Lars; Seese, Anita; Barthel, Henryk; Sattler, Bernhard; Sabri, Osama
2015-06-21
This study explores the possibility of using simultaneous positron emission tomography--magnetic resonance imaging (PET-MRI) to estimate the lean body mass (LBM) in order to obtain a standardized uptake value (SUV) which is less dependent on the patients' adiposity. This approach is compared to (1) the commonly-used method based on a predictive equation for LBM, and (2) to using an LBM derived from PET-CT data. It is hypothesized that an MRI-based correction of SUV provides a robust method due to the high soft-tissue contrast of MRI. A straightforward approach to calculate an MRI-derived LBM is presented. It is based on the fat and water images computed from the two-point Dixon MRI primarily used for attenuation correction in PET-MRI. From these images, a water fraction was obtained for each voxel. Averaging over the whole body yielded the weight-normalized LBM. Performance of the new approach in terms of reducing variations of (18)F-Fludeoxyglucose SUVs in brain and liver across 19 subjects was compared with results using predictive methods and PET-CT data to estimate the LBM. The MRI-based method reduced the coefficient of variation of SUVs in the brain by 41 ± 10% which is comparable to the reduction by the PET-CT method (35 ± 10%). The reduction of the predictive LBM method was 29 ± 8%. In the liver, the reduction was less clear, presumably due to other sources of variation. In conclusion, employing the Dixon data in simultaneous PET-MRI for calculation of lean body mass provides a brain SUV which is less dependent on patient adiposity. The reduced dependency is comparable to that obtained by CT and predictive equations. Therefore, it is more comparable across patients. The technique does not impose an overhead in measurement time and is straightforward to implement.
Recent Trends in Soft Tissue Infection Imaging
Petruzzi, Nicholas; Shanthly, Nylla; Thakur, Mathew
2009-01-01
This article discusses the current techniques and future directions of infection imaging with particular attention to respiratory, CNS, abdominal, and postoperative infections. The agents currently in use localize to areas of infection and inflammation. An infection specific imaging agent would greatly improve the utility of scintigraphy in imaging occult infections. The superior spatial resolution of 18F-FDG PET and its lack of reliance on a functional immune system, gives this agent certain advantages over the other radiopharmaceuticals. In respiratory infection imaging, an important advancement would be the ability to quantitatively delineate lung inflammation, allowing one to monitor the therapeutic response in a variety of conditions. Current studies suggest PET should be considered the most accurate quantitative method. Scintigraphy has much to offer in localizing abdominal infection as well as inflammation. We may begin to see a gradual increase in the usage of FDG PET in detecting occult abdominal infections. Commonly used modalities for imaging inflammatory bowel disease are scintigraphy with 111In-oxine/99mTc-HMPAO labeled autologous white blood cells. The literature on CNS infection imaging is relatively scarce. Few clinical studies have been performed and numerous new agents have been developed for this use with varying results. Further studies are needed to more clearly delineate the future direction of this field. In evaluating the post-operative spine, 99mTc-ciprofloxacin SPECT was reported to be >80% sensitive in patients more than 6 months post-surgery. FDG PET has also been suggested for this purpose and may play a larger role than originally thought. It appears PET/CT is gaining support, especially in imaging those with fever of unknown origin or nonfunctional immune systems. While an infection specific agent is lacking, the development of one would greatly advance our ability to detect, localize, and quantify infections. Overall, imaging such an agent via SPECT/CT or PET/CT will pave the way for greater clinical reliability in the localization of infection. PMID:19187804
Cerenkov Luminescence Imaging as a Modality to Evaluate Antibody-Based PET Radiotracers
D’Souza, Jimson W.; Hensley, Harvey; Doss, Mohan; Beigarten, Charles; Torgov, Michael; Olafsen, Tove; Yu, Jian Q.
2017-01-01
Antibodies, and engineered antibody fragments, labeled with radioisotopes are being developed as radiotracers for the detection and phenotyping of diseases such as cancer. The development of antibody-based radiotracers requires extensive characterization of their in vitro and in vivo properties, including their ability to target tumors in an antigen-selective manner. In this study, we investigated the use of Cerenkov luminescence imaging (CLI) as compared with PET as a modality for evaluating the in vivo behavior of antibody-based radiotracers. Methods: The anti–prostate-specific membrane antigen (PSMA) huJ591 antibody (IgG; 150 kDa) and its minibody (Mb; 80 kDa) format were functionalized with the chelator 1,4,7-triazacyclononane-1-glutaric acid-4,7-diacetic acid (NODAGA) and radiolabeled with the positron-emitting radionuclide 64Cu (half-life, 12.7 h). Immunoreactive preparations of the radiolabeled antibodies were injected into NCr nu/nu mice harboring PSMA-positive CWR22Rv1 and PSMA-negative PC-3 tumor xenografts. Tumor targeting was evaluated by both PET and CLI. Results: 64Cu-NODAGA-PSMA-IgG and 64Cu-NODAGA-PSMA-Mb retained the ability to bind cell surface PSMA, and both radiotracers exhibited selective uptake into PSMA-positive tumors. Under the experimental conditions used, PSMA-selective uptake of 64Cu-NODAGA-PSMA-IgG and 64Cu-NODAGA-PSMA-Mb was observed by CLI as early as 3 h after injection, with tumor-to-background ratios peaking at 24 (IgG) and 16 (Mb) h after injection. Targeting data generated by CLI correlated with that generated by PET and necropsy. Conclusion: CLI provided a rapid and simple assessment of the targeting specificity and pharmacokinetics of the antibody-based PET radiotracers that correlated well with the behavior observed by standard PET imaging. Moreover, CLI provided clear discrimination between uptake kinetics of an intact IgG and its small-molecular-weight derivative Mb. These data support the use of CLI for the evaluation of radiotracer performance. PMID:27539844
NASA Astrophysics Data System (ADS)
Kutterolf, S.; Schindlbeck, J. C.; Anselmetti, F. S.; Ariztegui, D.; Brenner, M.; Curtis, J.; Schmid, D.; Hodell, D. A.; Mueller, A.; Pérez, L.; Pérez, W.; Schwalb, A.; Frische, M.; Wang, K.-L.
2016-10-01
Lake Petén Itzá, northern Guatemala, lies within a hydrologically closed basin in the south-central area of the Yucatán Peninsula, and was drilled under the auspices of the International Continental Scientific Drilling Program (ICDP) in 2006. At 16°55‧N latitude, the lake is ideally located for study of past climate and environmental conditions in the Neotropical lowlands. Because of its great depth (>160 m), Lake Petén Itzá has a record of continuous sediment accumulation that extends well into the late Pleistocene. A key obstacle to obtaining long climate records from the region is the difficulty of establishing a robust chronology beyond ∼40 ka, the limit of 14C dating. Tephra layers within the Lake Petén Itzá sediments, however, enable development of age/depth relations beyond 40 ka. Ash beds from large-magnitude, Pleistocene-to-Holocene silicic eruptions of caldera volcanoes along the Central American Volcanic Arc (CAVA) were found throughout drill cores collected from Lake Petén Itzá. These ash beds were used to establish a robust chronology extending back 400 ka. We used major- and trace-element glass composition to establish 12 well-constrained correlations between the lacustrine tephra layers in Lake Petén Itzá sediments and dated deposits at the CAVA source volcanoes, and with their marine equivalents in eastern Pacific Ocean sediments. The data also enabled revision of eight previous determinations of erupted volumes and masses, and initial estimates for another four eruptions, as well as the designation of source areas for 14 previously unknown eruptions. The new and revised sedimentation rates for the older sediment successions identify the interglacial of MIS5a between 84 and 72 ka, followed by a stadial between 72 and 59 ka that corresponds to MIS4. We modified the age models for the Lake Petén Itzá sediment sequences, extended the paleoclimate and paleoecological record for this Neotropical region to ∼400 ka, and determined the magnitude and timing of CAVA eruptions.
(18)F-FDG and (18)F-FLT PET/CT imaging in the characterization of mediastinal lymph nodes.
Rayamajhi, Sampanna Jung; Mittal, Bhagwant Rai; Maturu, Venkata Nagarjuna; Agarwal, Ritesh; Bal, Amanjit; Dey, Pranab; Shukla, Jaya; Gupta, Dheeraj
2016-04-01
There is currently no single modality for accurate characterization of enlarged mediastinal lymph nodes into benign or malignant. Recently (18)F-fluorothymidine (FLT) has been used as a proliferation marker. In this prospective study, we examined the role of (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography/computed tomography (PET/CT) and (18)F-FLT PET/CT in categorizing mediastinal lymph nodes as benign or malignant. A total of 70 consecutive patients with mediastinal lymphadenopathy detected on computed tomography (CT) or chest radiograph underwent whole body (18)F-FLT PET/CT and (18)F-FDG PET/CT (within 1 week of each other). Lymph nodal tracer uptake was determined by calculation of standardized uptake value (SUV) with both the tracers. Results of PET/CT were compared with histopathology of the lymph nodes. Histopathology results showed thirty-seven patients with sarcoidosis, seven patients with tuberculosis, nine patients with non-small cell lung cancer, five patients with Hodgkin's lymphoma and twelve patients with non-Hodgkin's lymphoma. The mean FDG SUVmax of sarcoidosis, tuberculosis, Hodgkin's and non-Hodgkin's lymphoma was 12.7, 13.4, 8.2, and 8.8, respectively, and the mean FLT SUVmax was 6.0, 5.4, 4.4, and 3.8, respectively. It was not possible to characterize mediastinal lymphadenopathy as benign or malignant solely based on FDG SUVmax values (p > 0.05) or FLT SUVmax values (p > 0.05). There was no significant difference in FDG uptake (p > 0.9) or FLT uptake (p > 0.9) between sarcoidosis and tuberculosis. In lung cancer patients, the FDG SUVmax and FLT SUVmax of those lymph nodes with tumor infiltration on biopsy was 6.7 and 3.9, respectively, and those without nodal infiltration was 6.4 and 3.7, respectively, and both the tracers were not able to characterize the nodal status as malignant or benign (p > 0.05). Though (18)F-FLT PET/CT and (18)F-FDG PET/CT reflect different aspects of biology, i.e., proliferation and metabolism, respectively, neither tracer could provide satisfactory categorization of benign and malignant lymph nodes. The results of this study clearly suggest that differentiation of mediastinal nodes into benign and malignant solely based on SUVmax values cannot be relied upon, especially in settings where tuberculosis and sarcoidosis are common.
Szanda, Istvan; Mackewn, Jane; Patay, Gergely; Major, Peter; Sunassee, Kavitha; Mullen, Gregory E; Nemeth, Gabor; Haemisch, York; Blower, Philip J; Marsden, Paul K
2011-11-01
The NanoPET/CT represents the latest generation of commercial preclinical PET/CT systems. This article presents a performance evaluation of the PET component of the system according to the National Electrical Manufacturers Association (NEMA) NU-4 2008 standard. The NanoPET/CT consists of 12 lutetium yttrium orthosilicate:cerium modular detectors forming 1 ring, with 9.5-cm axial coverage and a 16-cm animal port. Each detector crystal is 1.12 × 1.12 × 13 mm, and 1 module contains 81 × 39 of these crystals. An optical light guide transmits the scintillation light to the flat-panel multianode position-sensitive photomultiplier tubes. Analog-to-digital converter cards and a field-programmable gate array-based data-collecting card provide the readout. Spatial resolution, sensitivity, counting rate capabilities, and image quality were evaluated in accordance with the NEMA NU-4 standard. Energy and temporal resolution measurements and a mouse imaging study were performed in addition to the standard. Energy resolution was 19% at 511 keV. The spatial resolution, measured as full width at half maximum on single-slice rebinning/filtered backprojection-reconstructed images, approached 1 mm on the axis and remained below 2.5 mm in the central 5-cm transaxial region both in the axial center and at one-quarter field of view. The maximum absolute sensitivity for a point source at the center of the field of view was 7.7%. The maximum noise equivalent counting rates were 430 kcps at 36 MBq and 130 kcps at 27 MBq for the mouse- and rat-sized phantoms, respectively. The uniformity and recovery coefficients were measured with the image-quality phantom, giving good-quality images. In a mouse study with an (18)F-labeled thyroid-specific tracer, the 2 lobes of the thyroid were clearly distinguishable, despite the small size of this organ. The flexible readout system allowed experiments to be performed in an efficient manner, and the system remained stable throughout. The large number of detector crystals, arranged with a fine pitch, results in excellent spatial resolution, which is the best reported for currently available commercial systems. The absolute sensitivity is high over the field of view. Combined with the excellent image quality, these features make the NanoPET/CT a powerful tool for preclinical research.
Decreased occipital lobe metabolism by FDG-PET/CT
Solnes, Lilja; Nalluri, Abhinav; Cohen, Jesse; Jones, Krystyna M.; Zan, Elcin; Javadi, Mehrbod S.; Venkatesan, Arun
2017-01-01
Objective: To compare brain metabolism patterns on fluorodeoxyglucose (FDG)-PET/CT in anti–NMDA receptor and other definite autoimmune encephalitis (AE) and to assess how these patterns differ between anti–NMDA receptor neurologic disability groups. Methods: Retrospective review of clinical data and initial dedicated brain FDG-PET/CT studies for neurology inpatients with definite AE, per published consensus criteria, treated at a single academic medical center over a 10-year period. Z-score maps of FDG-PET/CT were made using 3-dimensional stereotactic surface projections in comparison to age group–matched controls. Brain region mean Z scores with magnitudes ≥2.00 were interpreted as significant. Comparisons were made between anti–NMDA receptor and other definite AE patients as well as among patients with anti–NMDA receptor based on modified Rankin Scale (mRS) scores at the time of FDG-PET/CT. Results: The medial occipital lobes were markedly hypometabolic in 6 of 8 patients with anti–NMDA receptor encephalitis and as a group (Z = −4.02, interquartile range [IQR] 2.14) relative to those with definite AE (Z = −2.32, 1.46; p = 0.004). Among patients with anti–NMDA receptor encephalitis, the lateral and medial occipital lobes were markedly hypometabolic for patients with mRS 4–5 (lateral occipital lobe Z = −3.69, IQR 1; medial occipital lobe Z = −4.08, 1) compared with those with mRS 0–3 (lateral occipital lobe Z = −0.83, 2; p < 0.0005; medial occipital lobe Z = −1.07, 2; p = 0.001). Conclusions: Marked medial occipital lobe hypometabolism by dedicated brain FDG-PET/CT may serve as an early biomarker for discriminating anti–NMDA receptor encephalitis from other AE. Resolution of lateral and medial occipital hypometabolism may correlate with improved neurologic status in anti–NMDA receptor encephalitis. PMID:29159205
NASA Astrophysics Data System (ADS)
Yoon, Hyun Jin; Jeong, Young Jin; Son, Hye Joo; Kang, Do-Young; Hyun, Kyung-Yae; Lee, Min-Kyung
2015-01-01
The spatial resolution in positron emission tomography (PET) is fundamentally limited by the geometry of the detector element, the positron's recombination range with electrons, the acollinearity of the positron, the crystal decoding error, the penetration into the detector ring, and the reconstruction algorithms. In this paper, optimized parameters are suggested to produce high-resolution PET images by using an iterative reconstruction algorithm. A phantom with three point sources structured with three capillary tubes was prepared with an axial extension of less than 1 mm and was filled with 18F-fluorodeoxyglucose (18F-FDG) with concentrations above 200 MBq/cc. The performance measures of all the PET images were acquired according to the National Electrical Manufacturers Association (NEMA) NU 2-2007 standards procedures. The parameters for the iterative reconstruction were adjusted around the values recommended by General Electric GE, and the optimized values of the spatial resolution and the full width at half maximum (FWHM) or the full width at tenth of maximum (FWTM) values were found for the best PET resolution. The axial and the transverse spatial resolutions, according to the filtered back-projection (FBP) at 1 cm off-axis, were 4.81 and 4.48 mm, respectively. The axial and the transaxial spatial resolutions at 10 cm off-axis were 5.63 mm and 5.08 mm, respectively, and the trans-axial resolution at 10 cm was evaluated as the average of the radial and the tangential measurements. The recommended optimized parameters of the spatial resolution according to the NEMA phantom for the number of subsets, the number of iterations, and the Gaussian post-filter are 12, 3, and 3 mm for the iterative reconstruction VUE Point HD without the SharpIR algorithm (HD), and 12, 12, and 5.2 mm with SharpIR (HD.S), respectively, according to the Advantage Workstation Volume Share 5 (AW4.6). The performance measurements for the GE Discovery PET/CT 710 using the NEMA NU 2-2007 standards from our results will be helpful in the quantitative analysis of PET scanner images. The spatial resolution was modified more by using an improved algorithm such as HD.S, than by using HD and FBP. The use of the optimized parameters for iterative reconstructions is strongly recommended for qualitative images from the GE Discovery PET/CT 710 scanner.
Hindié, Elif
2017-01-01
Neuroendocrine tumors (NET) are often metastatic at the time of diagnosis. Metastatic well-differentiated (G1/G2) NET may display a wide range of behaviors, ranging from indolent to aggressive, even within apparently homogeneous categories. Thus, selecting the optimal treatment strategy is a challenging task. Somatostatin receptor imaging (SRI) is the standard molecular imaging technique for well-differentiated NET. When performed with 68 Ga-labeled somatostatin analogs (SRI-PET), it offers exquisite sensitivity for disease staging. SRI is also a prerequisite for using targeted radionuclide therapy (e.g. 177 Lu-DOTATATE). 18F-FDG imaging has traditionally been reserved for staging poorly-differentiated G3 neuroendocrine carcinomas. However, recent data showed that FDG imaging has prognostic value in patients with well-differentiated NET: high uptake was associated with an increased risk of early progression while low uptake suggested an indolent tumor. In this issue of the Journal, Chan and colleagues propose a grading system where the results from the combined reading of SRI-PET and FDG-PET are reported as a single parameter, the "NETPET" score. While the scoring system still needs validation, it is clear that time has come to think about FDG and SRI in metastatic NET not as competitors but as complementary imaging modalities. Dual-tracer imaging can be viewed as a way to characterize disease phenotype in the whole-body. Moving from the prognostic value of dual-tracer imaging to a tool that allows for individualized management would require prospective trials. This editorial will argue that dual-tracer FDG-PET and SRI-PET might influence management of patients with well-differentiated metastatic NET and help selecting between different therapy options.
Elmaleh, D. R.; Fischman, A. J.; Tawakol, A.; Zhu, A.; Shoup, T. M.; Hoffmann, U.; Brownell, A.-L.; Zamecnik, P. C.
2006-01-01
Diadenosine-5′,5‴-P1,P4-tetraphosphate (Ap4A) and its analog P2,P3-monochloromethylene diadenosine-5′,5‴-P1,P4-tetraphosphate (AppCHClppA) are competitive inhibitors of adenosine diphosphate-induced platelet aggregation, which plays a central role in arterial thrombosis and plaque formation. In this study, we evaluate the imaging capabilities of positron-emission tomography (PET) with P2,P3-[18F]monofluoromethylene diadenosine-5′,5‴-P1,P4-tetraphosphate ([18F]AppCHFppA) to detect atherosclerotic lesions in male New Zealand White rabbits. Three to six months after balloon injury to the aorta, the rabbits were injected with [18F]AppCHFppA, and microPET imaging showed rapid accumulation of this radiopharmaceutical in the atherosclerotic abdominal aorta, with lesions clearly visible 30 min after injection. Computed tomographic images were coregistered with PET images to improve delineation of aortoiliac tracer activity. Plaque macrophage density, quantified by immunostaining with RAM11 against rabbit macrophages, correlated with PET measurements of [18F]AppCHFppA uptake (r = 0.87, P < 0.0001), whereas smooth-muscle cell density, quantified by immunostaining with 1A4 against smooth muscle actin, did not. Biodistribution studies of [18F]AppCHFppA in normal rats indicated typical adenosine dinucleotide behavior with insignificant myocardial uptake and fast kidney clearance. The accumulation of [18F]AppCHFppA in macrophage-rich atherosclerotic plaques can be quantified noninvasively with PET. Hence, [18F]AppCHFppA holds promise for the noninvasive characterization of vascular inflammation. PMID:17038498
68Ga-DOTA-Siglec-9--a new imaging tool to detect synovitis.
Virtanen, Helena; Autio, Anu; Siitonen, Riikka; Liljenbäck, Heidi; Saanijoki, Tiina; Lankinen, Petteri; Mäkilä, Jussi; Käkelä, Meeri; Teuho, Jarmo; Savisto, Nina; Jaakkola, Kimmo; Jalkanen, Sirpa; Roivainen, Anne
2015-11-03
Vascular adhesion protein-1 (VAP-1) is an adhesion molecule, which upon inflammation is rapidly translocated from intracellular sources to the endothelial cell surface. We have recently discovered that sialic acid- binding immunoglobulin-like lectin 9 (Siglec-9) is a leukocyte ligand of VAP-1 and that 68Ga-labeled Siglec-9 motif peptide facilitates in vivo imaging of inflammation. This study evaluated the feasibility of 68Ga-DOTA-Siglec-9 positron emission tomography (PET) for the assessment of synovitis. Rabbits with synovial inflammation were injected with 18F-FDG or 68Ga-DOTA-Siglec-9 and studied by gamma counting and autoradiography. Certain rabbits were also examined with magnetic resonance imaging (MRI). After PET imaging, rabbits were intravenously administered with anti-VAP-1 antibody to evaluate luminal expression of VAP-1 by immunohistochemistry. Finally, binding of Siglec-9 peptide and VAP-1 positive vessels were evaluated by double staining of rheumatoid arthritis synovium. Intra-articular injection of hemagglutinin induced mild synovial inflammation in rabbit knee with luminal expression of VAP-1. Synovitis was clearly visualized by 68Ga-DOTA-Siglec-9 PET in addition to 18F-FDG-PET and MRI. Compared with the 18F-FDG, the ex vivo inflamed-to-control synovium ratio of 68Ga-DOTA-Siglec-9 was similar (1.7 ± 0.4 vs. 1.5 ± 0.2, P = 0.32). Double staining revealed that Siglec-9 peptide binds to VAP-1 positive vessels in human rheumatoid synovium. Ga-DOTA-Siglec-9 PET tracer detected VAP-1 positive vasculature in the mild synovitis of rabbits comparable with 18F-FDG, suggesting its potential for in vivo imaging of synovial inflammation in patients with rheumatic diseases.
Park, Ju Hui; Kim, Kwang Il; Lee, Kyo Chul; Lee, Yong Jin; Lee, Tae Sup; Chung, Wee Sup; Lim, Sang Moo; Kang, Joo Hyun
2015-02-01
Tumor-specific enhancer/promoter is applicable for targeting gene expression in tumors and helpful for tumor-targeting imaging and therapy. We aimed to acquire α-fetoprotein (AFP)-producing hepatocellular carcinoma (HCC) specific images using adenovirus containing HSV1-tk gene controlled by AFP enhancer/promoter and evaluate in vivo ganciclovir (GCV)-medicated therapeutic effects on AFP-targeted HSV1-tk expression with (18)F-FDG positron emission tomography (PET). Recombinant adenovirus expressing HSV1-tk under AFP enhancer/promoter was produced (AdAFP-TK) and the expression levels were evaluated by RT-PCR and (125)I-IVDU uptake. GCV-mediated HSV1-tk cytotoxicity was determined by MTT assay. After the mixture of AdAFP-fLuc and AdAFP-TK was administrated, bioluminescent images (BLIs) and (18)F-FHBG PET images were obtained in tumor-bearing mice. In vivo therapeutic effects of AdAFP-TK and GCV in the HuH-7 xenograft model were monitored by (18)F-FDG PET. When infected with AdAFP-TK, cell viability in HuH-7 was reduced, but those in HT-29 and SK-Hep-1 were not significantly decreased at any GCV concentration less than 100 μM. AFP-targeted fLuc and HSV1-tk expression were clearly visualized by BLI and (18)F-FHBG PET images in AFP-producing HCC, respectively. In vivo GCV-mediated tumor growth inhibition by AFP-targeted HSV1-tk expression was monitored by (18)F-FDG PET. Recombinant AdAFP-TK could be applied for AFP-targeted HCC gene therapy and imaging in AFP-producing HCC.
Study on the leaching of phthalates from polyethylene terephthalate bottles into mineral water.
Keresztes, Szilvia; Tatár, Enikő; Czégény, Zsuzsanna; Záray, Gyula; Mihucz, Victor G
2013-08-01
Carbonated and non-carbonated mineral water samples bottled in 0.5-L, 1.5-L and 2.0-L polyethylene terephthalate (PET) containers belonging to three different water brands commercialized in Hungary were studied in order to determine their phthalate content by gas chromatography-mass spectrometry. Among the six investigated phthalates, diisobutyl phthalate, di-n-butyl-phthalate, benzyl-butyl phthalate and di(2-ethyl-hexyl) phthalate (DEHP) were determined in non-carbonated samples as follows: <3.0 ng L(-1)-0.2 μg L(-1), <6.6 ng L(-1)-0.8 μg L(-1), <6.0 ng L(-1)-0.1 μg L(-1) and <16.0 ng L(-1)-1.7 μg L(-1), respectively. Any of the above-mentioned phthalate esters could be detected in carbonated mineral water samples. DEHP was the most abundant phthalate in the investigated samples. It could be detected after 44 days of storage at 22 °C and its leaching was the most pronounced when samples were stored over 1200 days. Mineral water purchased in PET bottles of 0.5L had the highest phthalate concentrations compared to those obtained for waters of the identical brand bottled in 1.5-L or 2.0-L PET containers due to the higher surface/volume ratio. No clear trend could be established for phthalate leaching when water samples were kept at higher temperatures (max. 60 °C) showing improper storage conditions. Phthalate determination by pyrolysis-gas chromatography/mass spectrometric measurements in the plastic material as well as in the aqueous phase proved the importance of the quality of PET raw material used for the production of the pre-form (virgin vs. polymer containing recycled PET). Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wong, Wai-Hoi; Li, Hongdi; Zhang, Yuxuan; Ramirez, Rocio; An, Shaohui; Wang, Chao; Liu, Shitao; Dong, Yun; Baghaei, Hossain
2015-10-01
We developed a high-resolution Photomultiplier-Quadrant-Sharing (PQS) PET system for human imaging. This system is made up of 24 detector panels. Each panel (bank) consists of 3 ×7 detector blocks, and each block has 16 ×16 LYSO crystals of 2.35 ×2.35 ×15.2 mm3. We used a novel detector-grinding scheme that is compatible with the PQS detector-pixel-decoding requirements to make a gapless cylindrical detector ring for maximizing detection efficiency while delivering an ultrahigh spatial-resolution for a whole-body PET camera with a ring diameter of 87 cm and axial field of view of 27.6 cm. This grinding scheme enables two adjacent gapless panels to share one row of the PMTs to extend the PQS configuration beyond one panel and thus maximize the economic benefit (in PMT usage) of the PQS design. The entire detector ring has 129,024 crystals, all of which are clearly decoded using only 576 PMTs (38-mm diameter). Thus, each PMT on average decodes 224 crystals to achieve a high crystal-pitch resolution of 2.44 mm ×2.44 mm. The detector blocks were mass-produced with our slab-sandwich-slice technique using a set of optimized mirror-film patterns (between crystals) to maximize light output and achieve high spatial and timing resolution. This detection system with time-of-flight capability was placed in a human PET/CT gantry. The reconstructed image resolution of the system was about 2.87 mm using 2D-filtered back-projection. The time-of-flight resolution was 473 ps. The preliminary images of phantoms and clinical studies presented in this work demonstrate the capability of this new PET/CT system to produce high-quality images.
Palko, Heather A; Fung, Jennifer Y; Louie, Angelique Y
2010-07-01
Particulate matter (PM) has been associated with serious health effects within but also outside of the pulmonary system. Therefore, there is great interest in studying the biodistribution of PM after delivery to the lung to correlate sites of extrapulmonary particle accumulation and abnormal conditions known to be associated with PM exposure. Traditional PM tracking studies have introduced nanoparticles to animal models or humans and have determined the biodistribution with gamma counting, gamma camera, and inductively coupled plasma mass spectrometry (ICP-MS). The authors here demonstrate that positron emission tomography (PET) is a powerful tool that can be employed to visualize the deposition and track the fate of nanoparticles in the mouse model. In these studies, approximately 100-nm polystyrene nanoparticles were labeled with the positron emitter 64Cu bound by the chelator (S)-2-(4-isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane-tetraacetic acid (p-SCN-Bn-DOTA). The labeled nanoparticles were instilled intratracheally into C57BL/6 mice; the initial deposition and biodistribution through 48 h was determined by PET imaging. In addition to static imaging, dynamic imaging was performed in the Sprague-Dawley rat model to demonstrate that PET can capture particle movement in pseudo-time-lapse videos. Particle deposition and clearance was clearly identified by PET, and the same animals could be imaged repeatedly without any adverse effects from anesthesia. PET has the potential to require many fewer animals than traditional methods while still providing quantitative results. In addition, the initial deposition pattern in each animal can be accurately determined and the same animal monitored over time so that data interpretation is not clouded by variations in initial deposition profiles.
Optimized MLAA for quantitative non-TOF PET/MR of the brain
NASA Astrophysics Data System (ADS)
Benoit, Didier; Ladefoged, Claes N.; Rezaei, Ahmadreza; Keller, Sune H.; Andersen, Flemming L.; Højgaard, Liselotte; Hansen, Adam E.; Holm, Søren; Nuyts, Johan
2016-12-01
For quantitative tracer distribution in positron emission tomography, attenuation correction is essential. In a hybrid PET/CT system the CT images serve as a basis for generation of the attenuation map, but in PET/MR, the MR images do not have a similarly simple relationship with the attenuation map. Hence attenuation correction in PET/MR systems is more challenging. Typically either of two MR sequences are used: the Dixon or the ultra-short time echo (UTE) techniques. However these sequences have some well-known limitations. In this study, a reconstruction technique based on a modified and optimized non-TOF MLAA is proposed for PET/MR brain imaging. The idea is to tune the parameters of the MLTR applying some information from an attenuation image computed from the UTE sequences and a T1w MR image. In this MLTR algorithm, an {αj} parameter is introduced and optimized in order to drive the algorithm to a final attenuation map most consistent with the emission data. Because the non-TOF MLAA is used, a technique to reduce the cross-talk effect is proposed. In this study, the proposed algorithm is compared to the common reconstruction methods such as OSEM using a CT attenuation map, considered as the reference, and OSEM using the Dixon and UTE attenuation maps. To show the robustness and the reproducibility of the proposed algorithm, a set of 204 [18F]FDG patients, 35 [11C]PiB patients and 1 [18F]FET patient are used. The results show that by choosing an optimized value of {αj} in MLTR, the proposed algorithm improves the results compared to the standard MR-based attenuation correction methods (i.e. OSEM using the Dixon or the UTE attenuation maps), and the cross-talk and the scale problem are limited.
High-performance electronics for time-of-flight PET systems
NASA Astrophysics Data System (ADS)
Choong, W.-S.; Peng, Q.; Vu, C. Q.; Turko, B. T.; Moses, W. W.
2013-01-01
We have designed and built a high-performance readout electronics system for time-of-flight positron emission tomography (TOF PET) cameras. The electronics architecture is based on the electronics for a commercial whole-body PET camera (Siemens/CPS Cardinal electronics), modified to improve the timing performance. The fundamental contributions in the electronics that can limit the timing resolution include the constant fraction discriminator (CFD), which converts the analog electrical signal from the photo-detector to a digital signal whose leading edge is time-correlated with the input signal, and the time-to-digital converter (TDC), which provides a time stamp for the CFD output. Coincident events are identified by digitally comparing the values of the time stamps. In the Cardinal electronics, the front-end processing electronics are performed by an Analog subsection board, which has two application-specific integrated circuits (ASICs), each servicing a PET block detector module. The ASIC has a built-in CFD and TDC. We found that a significant degradation in the timing resolution comes from the ASIC's CFD and TDC. Therefore, we have designed and built an improved Analog subsection board that replaces the ASIC's CFD and TDC with a high-performance CFD (made with discrete components) and TDC (using the CERN high-performance TDC ASIC). The improved Analog subsection board is used in a custom single-ring LSO-based TOF PET camera. The electronics system achieves a timing resolution of 60 ps FWHM. Prototype TOF detector modules are read out with the electronics system and give coincidence timing resolutions of 259 ps FWHM and 156 ps FWHM for detector modules coupled to LSO and LaBr3 crystals respectively.
Lymph node detection in IASLC-defined zones on PET/CT images
NASA Astrophysics Data System (ADS)
Song, Yihua; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.
2016-03-01
Lymph node detection is challenging due to the low contrast between lymph nodes as well as surrounding soft tissues and the variation in nodal size and shape. In this paper, we propose several novel ideas which are combined into a system to operate on positron emission tomography/ computed tomography (PET/CT) images to detect abnormal thoracic nodes. First, our previous Automatic Anatomy Recognition (AAR) approach is modified where lymph node zones predominantly following International Association for the Study of Lung Cancer (IASLC) specifications are modeled as objects arranged in a hierarchy along with key anatomic anchor objects. This fuzzy anatomy model built from diagnostic CT images is then deployed on PET/CT images for automatically recognizing the zones. A novel globular filter (g-filter) to detect blob-like objects over a specified range of sizes is designed to detect the most likely locations and sizes of diseased nodes. Abnormal nodes within each automatically localized zone are subsequently detected via combined use of different items of information at various scales: lymph node zone model poses found at recognition indicating the geographic layout at the global level of node clusters, g-filter response which hones in on and carefully selects node-like globular objects at the node level, and CT and PET gray value but within only the most plausible nodal regions for node presence at the voxel level. The models are built from 25 diagnostic CT scans and refined for an object hierarchy based on a separate set of 20 diagnostic CT scans. Node detection is tested on an additional set of 20 PET/CT scans. Our preliminary results indicate node detection sensitivity and specificity at around 90% and 85%, respectively.
Smith, Eric E; Muzikansky, Alona; McCreary, Cheryl R; Batool, Saima; Viswanathan, Anand; Dickerson, Bradford C; Johnson, Keith; Greenberg, Steven M; Blacker, Deborah
2018-01-01
Hypertension is the strongest modifiable risk factor for subcortical ischemic changes and is also a risk factor for Alzheimer's dementia. We used neuroimaging to investigate the pathological basis of early cognitive symptoms in patients with hypertension. In this cross-sectional cohort study 67 patients age >60 years with hypertension and Clinical Dementia Rating scale score of 0.5 without dementia, and without history of symptomatic stroke, underwent MRI for measurement of subcortical vascular changes and positron emission tomography (PET) scan with Pittsburgh Compound B (PiB-PET) to detect beta-amyloid deposition. These imaging measures were related to neuropsychological tests of memory, executive function and processing speed. Mean age was 75.0 (standard deviation, SD, 7.3). Mean neuropsychological Z scores were: episodic memory -0.63 (SD 1.23), executive function -0.40 (SD 1.10), processing speed -0.24 (SD 0.88); 22 of the 67 subjects met criteria for mild cognitive impairment (MCI) and the remaining 45 subjects had subjective cognitive concerns only. In multivariable models adjusting for age and years of education, each 0.1 unit increase in mean cortical PiB-PET binding was associated with 0.14 lower mean Z score for episodic memory (95% CI -0.28 to -0.01). This means that for every 0.1 unit increase in mean cortical PiB-PET, episodic memory was 0.14 standard deviations lower. White matter hyperintensity volume, silent brain infarcts and microbleeds were not associated with neuropsychological test scores. Episodic memory was prominently affected in hypertensive participants with MCI or subjective cognitive concerns, and was associated with PiB-PET binding. This suggests a prominent role for Alzheimer pathology in cognitive impairment even in hypertensive participants at elevated risk for vascular cognitive impairment.
Park, Hae-Jeong; Park, Bumhee; Kim, Hae Yu; Oh, Maeng-Keun; Kim, Joong Il; Yoon, Misun; Lee, Jong Doo; Chang, Jin Woo
2015-05-01
As Parkinson's disease (PD) can be considered a network abnormality, the effects of deep brain stimulation (DBS) need to be investigated in the aspect of networks. This study aimed to examine how DBS of the bilateral subthalamic nucleus (STN) affects the motor networks of patients with idiopathic PD during motor performance and to show the feasibility of the network analysis using cross-sectional positron emission tomography (PET) images in DBS studies. We obtained [¹⁵O]H₂O PET images from ten patients with PD during a sequential finger-to-thumb opposition task and during the resting state, with DBS-On and DBS-Off at STN. To identify the alteration of motor networks in PD and their changes due to STN-DBS, we applied independent component analysis (ICA) to all the cross-sectional PET images. We analysed the strength of each component according to DBS effects, task effects and interaction effects. ICA blindly decomposed components of functionally associated distributed clusters, which were comparable to the results of univariate statistical parametric mapping. ICA further revealed that STN-DBS modifies usage-strengths of components corresponding to the basal ganglia-thalamo-cortical circuits in PD patients by increasing the hypoactive basal ganglia and by suppressing the hyperactive cortical motor areas, ventrolateral thalamus and cerebellum. Our results suggest that STN-DBS may affect not only the abnormal local activity, but also alter brain networks in patients with PD. This study also demonstrated the usefulness of ICA for cross-sectional PET data to reveal network modifications due to DBS, which was not observable using the subtraction method.
Mallik, Atul; Drzezga, Alex; Minoshima, Satoshi
2017-01-01
Amyloid plaques, along with neurofibrillary tangles, are a neuropathologic hallmark of Alzheimer disease (AD). Recently, amyloid PET radiotracers have been developed and approved for clinical use in the evaluation of suspected neurodegenerative disorders. In both research and clinical settings, amyloid PET imaging has provided important diagnostic and prognostic information for the management of patients with possible AD, mild cognitive impairment (MCI), and other challenging diagnostic presentations. Although the overall impact of amyloid imaging is still being evaluated, the Society of Nuclear Medicine and Molecular Imaging and Alzheimer's Association Amyloid Imaging Task Force have created appropriate use criteria for the standard clinical use of amyloid PET imaging. By the appropriate use criteria, amyloid imaging is appropriate for patients with (1) persistent or unexplained MCI, (2) AD as a possible but still uncertain diagnosis after expert evaluation and (3) atypically early-age-onset progressive dementia. To better understand the clinical and economic effect of amyloid imaging, the Imaging Dementia-Evidence for Amyloid Scanning (IDEAS) study is an ongoing large multicenter study in the United States, which is evaluating how amyloid imaging affects diagnosis, management, and outcomes for cognitively impaired patients who cannot be completely evaluated by clinical assessment alone. Multiple other large-scale studies are evaluating the prognostic role of amyloid PET imaging for predicting MCI progression to AD in general and high-risk populations. At the same time, amyloid imaging is an important tool for evaluating potential disease-modifying therapies for AD. Overall, the increased use of amyloid PET imaging has led to a better understanding of the strengths and limitations of this imaging modality and how it may best be used with other clinical, molecular, and imaging assessment techniques for the diagnosis and management of neurodegenerative disorders. Copyright © 2017 Elsevier Inc. All rights reserved.
Ganguly, Tanushree; Dannoon, Shorouk; Hopkins, Mark R.; ...
2015-06-09
Here in this study, a structurally modified phosphoramidate scaffold, with improved prostate-specific membrane antigen (PSMA) avidity, stability and in vivo characteristics, as a PET imaging agent for prostate cancer (PCa), was prepared and evaluated. p-Fluorobenzoyl-aminohexanoate and 2-(3-hydroxypropyl)glycine were introduced into the PSMA-targeting scaffold yielding phosphoramidate 5. X-ray crystallography was performed on the PSMA/5 complex. [ 18F]5 was synthesized, and cell uptake and internalization studies were conducted in PSMA(+) LNCaP and CWR22Rv1 cells and PSMA(-) PC-3 cells. In vivo PET imaging and biodistribution studies were performed at 1 and 4 h post injection in mice bearing CWR22Rv1 tumor, with or withoutmore » blocking agent. The crystallographic data showed interaction of the p-fluorobenzoyl group with an arene-binding cleft on the PSMA surface. In vitro studies revealed elevated uptake of [ 18F]5 in PSMA(+) cells (2.2% in CWR22Rv1 and 12.1% in LNCaP) compared to PSMA(-) cells (0.08%) at 4 h. In vivo tumor uptake of 2.33% ID/g and tumor-to-blood ratio of 265:1 was observed at 4 h. In conclusion, we have successfully synthesized, radiolabeled and evaluated a new PSMA-targeted PET agent. The crystal structure of the PSMA/5 complex highlighted the interactions within the arene-binding cleft contributing to the overall complex stability. The high target uptake and rapid non-target clearance exhibited by [ 18F]5 in PSMA(+) xenografts substantiates its potential use for PET imaging of PCa.« less
High-performance electronics for time-of-flight PET systems.
Choong, W-S; Peng, Q; Vu, C Q; Turko, B T; Moses, W W
2013-01-01
We have designed and built a high-performance readout electronics system for time-of-flight positron emission tomography (TOF PET) cameras. The electronics architecture is based on the electronics for a commercial whole-body PET camera (Siemens/CPS Cardinal electronics), modified to improve the timing performance. The fundamental contributions in the electronics that can limit the timing resolution include the constant fraction discriminator (CFD), which converts the analog electrical signal from the photo-detector to a digital signal whose leading edge is time-correlated with the input signal, and the time-to-digital converter (TDC), which provides a time stamp for the CFD output. Coincident events are identified by digitally comparing the values of the time stamps. In the Cardinal electronics, the front-end processing electronics are performed by an Analog subsection board, which has two application-specific integrated circuits (ASICs), each servicing a PET block detector module. The ASIC has a built-in CFD and TDC. We found that a significant degradation in the timing resolution comes from the ASIC's CFD and TDC. Therefore, we have designed and built an improved Analog subsection board that replaces the ASIC's CFD and TDC with a high-performance CFD (made with discrete components) and TDC (using the CERN high-performance TDC ASIC). The improved Analog subsection board is used in a custom single-ring LSO-based TOF PET camera. The electronics system achieves a timing resolution of 60 ps FWHM. Prototype TOF detector modules are read out with the electronics system and give coincidence timing resolutions of 259 ps FWHM and 156 ps FWHM for detector modules coupled to LSO and LaBr 3 crystals respectively.
Kelly-Morland, Christian; Rudman, Sarah; Nathan, Paul; Mallett, Susan; Montana, Giovanni; Cook, Gary; Goh, Vicky
2017-06-02
Tyrosine kinase inhibitors are the first line standard of care for treatment of metastatic renal cell carcinoma (RCC). Accurate response assessment in the setting of antiangiogenic therapies remains suboptimal as standard size-related response criteria do not necessarily accurately reflect clinical benefit, as they may be less pronounced or occur later in therapy than devascularisation. The challenge for imaging is providing timely assessment of disease status allowing therapies to be tailored to ensure ongoing clinical benefit. We propose that combined assessment of morphological, physiological and metabolic imaging parameters using 18F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging ( 18 F-FDG PET/MRI) will better reflect disease behaviour, improving assessment of response/non-response/relapse. The REMAP study is a single-centre prospective observational study. Eligible patients with metastatic renal cell carcinoma, planned for systemic therapy, with at least 2 lesions will undergo an integrated 18 F-FDG PET and MRI whole body imaging with diffusion weighted and contrast-enhanced multiphasic as well as standard anatomical MRI sequences at baseline, 12 weeks and 24 weeks of systemic therapy allowing 18 F-FDG standardised uptake value (SUV), apparent diffusion co-efficient (ADC) and normalised signal intensity (SI) parameters to be obtained. Standard of care contrast-enhanced computed tomography CT scans will be performed at equivalent time-points. CT response categorisation will be performed using RECIST 1.1 and alternative (modified)Choi and MASS criteria. The reference standard for disease status will be by consensus panel taking into account clinical, biochemical and conventional imaging parameters. Intra- and inter-tumoural heterogeneity in vascular, diffusion and metabolic response/non-response will be assessed by image texture analysis. Imaging will also inform the development of computational methods for automated disease status categorisation. The REMAP study will demonstrate the ability of integrated 18 F-FDG PET-MRI to provide a more personalised approach to therapy. We suggest that 18 F-FDG PET/MRI will provide superior sensitivity and specificity in early response/non-response categorisation when compared to standard CT (using RECIST 1.1 and alternative (modified)Choi or MASS criteria) thus facilitating more timely and better informed treatment decisions. The trial is approved by the Southeast London Research Ethics Committee reference 16/LO/1499 and registered on the NIHR clinical research network portfolio ISRCTN12114913 .
NASA Astrophysics Data System (ADS)
Knowles, J. F.; Lestak, L.; Molotch, N. P.
2016-12-01
We evaluated the long term (1989-2012) relationship between the satellite-observed Normalized Difference Vegetation Index (NDVI), snowpack accumulation, and atmospheric demand throughout the Southern Rocky Mountain Ecoregion, USA. Deviations from this relationship were further explored during pre- and post-disturbance conditions associated with bark beetles and drought. Over the entire study area, both the snow water equivalent (SWE) and a snow aridity index (SAI), which used the SWE to normalize potential evapotranspiration (PET), were significant predictors of the long-term AVHRR NDVI, but the SAI was a better predictor of NDVI relative to SWE regardless of disturbance. Since these relationships were weaker in disturbed areas, we also introduced a metric of tree mortality, and subsequent multiple linear regression of SAI and cumulative mortality best predicted the NDVI from a pair of heavily impacted focus areas within the larger study area. The post-disturbance NDVI was systematically reduced per unit SAI in these areas, and the difference between the observed and predicted (from pre-disturbance regressions) post-disturbance NDVI was significantly correlated with the cumulative forest mortality. At the Ecoregion scale, these disturbance effects were not clearly evident, and we attribute this to spatial variability of both SAI and NDVI throughout the large study area as evidenced by spatial analysis of Moderate Resolution Imaging Spectroradiometer (MODIS)-derived data. These results constrain the expected reduction in forest productivity due to disturbance and demonstrate that this reduction can be particularly evident during drought conditions resultant from low snow accumulation during the winter. Hence, terrestrial carbon uptake may decrease non-linearly post disturbance. This work has implications for predicting the ecohydrological response to climate change in the southern Rocky Mountains, as reductions in SWE and increases in PET are predicted for this area in the future, and therefore changes in the terrestrial carbon, water, and energy cycles should be expected.
Hideghéty, Katalin; Cserháti, Adrienne; Besenyi, Zsuzsanna; Zag, Levente; Gaál, Szilvia; Együd, Zsófia; Mózes, Petra; Szántó, Erika; Csenki, Melinda; Rusz, Orsolya; Varga, Zoltán; Dobi, Ágnes; Maráz, Anikó; Pávics, László; Lengyel, Zsolt
2015-06-01
The purpose of our work is evaluation of the impact of 18FDG-PET/CT on the complex management of locoregionally advanced (T3-4N1-3) head and neck squamous cell cancer (LAHNSC), and on the target definition for 3D conformal (3DCRT) and intensity-modulated radiotherapy (IMRT). 18FDG-PET/CT were performed on 185 patients with LAHNSC prior to radiotherapy/chemoradiation in the treatment position between 2006 and 2011. Prior to it 91 patients received induction chemotherapy (in 20 cases of these, baseline PET/CT was also available). The independently delineated CT-based gross tumor volume (GTVct) and PET/CT based ones (GTVpet) were compared. Impact of PET/CT on the treatment strategy, on tumor response evaluation to ICT, on GTV definition furthermore on overall and disease-specific survival (OS, DSS) was analysed. PET/CT revealed 10 head and neck, 2 lung cancers for 15 patients with carcinoma of unknown primary (CUP) while 3 remained unknown. Second tumors were detected in 8 (4.4%), distant metastasis in 15 (8.2%) cases. The difference between GTVct and GTVpet was significant (p=0.001). In 16 patients (14%) the GTVpet were larger than GTVct due to multifocal manifestations in the laryngo-pharyngeal regions (4 cases) or lymph node metastases (12 cases). In the majority of the cases (82 pts, 72%) PET/CT-based conturing resulted in remarkable decrease in the volume (15-20%: 4 cases, 20-50%: 46 cases, >50%: 32 cases). On the basis of the initial and post-ICT PET/CT comparison in 15/20 patients more than 50% volume reduction and in 6/20 cases complete response were achieved. After an average of 6.4 years of follow-up the OS (median: 18.3±2.6 months) and DSS (median: 25.0±4.0 months) exhibited close correlation (p=0.0001) to the GTVpet. In cases with GTVpet <10 cm3 prior to RT, DSS did not reach the median, the mean is 82.1±6.1 months, while in cases with GTVpet 10-40 cm3 the median of the DSS was 28.8±4.9 months (HR = 3.57; 95% CI: 1.5-8.3), and in those with GTVpet >40 cm3 the median DSS was 8.4±0.96 months (HR= 11.48; 95% CI: 5.3-24.9). Our results suggest that 18FDG-PET/CT plays an important role for patient with LAHNSC, by modifying the treatment concept and improving the target definition for selective RT modalities. Volumetric PET/CT-based assessment of the tumor response after ICT gives valuable contribution to further therapy planning.
2015-01-01
Zirconium-89 is an effective radionuclide for antibody-based positron emission tomography (PET) imaging because its physical half-life (78.41 h) matches the biological half-life of IgG antibodies. Desferrioxamine (DFO) is currently the preferred chelator for 89Zr4+; however, accumulation of 89Zr in the bones of mice suggests that 89Zr4+ is released from DFO in vivo. An improved chelator for 89Zr4+ could eliminate the release of osteophilic 89Zr4+ and lead to a safer PET tracer with reduced background radiation dose. Herein, we present an octadentate chelator 3,4,3-(LI-1,2-HOPO) (or HOPO) as a potentially superior alternative to DFO. The HOPO ligand formed a 1:1 Zr-HOPO complex that was evaluated experimentally and theoretically. The stability of 89Zr-HOPO matched or surpassed that of 89Zr-DFO in every experiment. In healthy mice, 89Zr-HOPO cleared the body rapidly with no signs of demetalation. Ultimately, HOPO has the potential to replace DFO as the chelator of choice for 89Zr-based PET imaging agents. PMID:24814511
The Business Of Urban Animals Survey: the facts and statistics on companion animals in Canada.
Perrin, Terri
2009-01-01
At the first Banff Summit for Urban Animal Strategies (BSUAS) in 2006, delegates clearly indicated that a lack of reliable Canadian statistics hampers municipal leaders and legislators in their efforts to develop urban animal strategies that create and sustain a healthy community for pets and people. To gain a better understanding of the situation, BSUAS municipal delegates and other industry stakeholders partnered with Ipsos Reid, one of the world's leading polling firms, to conduct a national survey on the "Business of Urban Animals." The results of the survey, summarized in this article, were presented at the BSUAS meeting in October 2008. In addition, each participating community will receive a comprehensive written analysis, as well as a customized report. The online survey was conducted from September 22 to October 1, 2008. There were 7208 participants, including 3973 pet and 3235 non-pet owners from the Ipsos-Reid's proprietary Canadian online panel. The national results were weighted to reflect the true population distribution across Canada and the panel was balanced on all major demographics to mirror Statistics Canada census information. The margin for error for the national results is 1/- 1.15%.
Laser-assisted immobilization of colloid silver nanoparticles on polyethyleneterephthalate
NASA Astrophysics Data System (ADS)
Siegel, Jakub; Lyutakov, Oleksiy; Polívková, Markéta; Staszek, Marek; Hubáček, Tomáš; Švorčík, Václav
2017-10-01
Immobilization of nanoobjects on the surface of underlying material belongs to current issues of material science. Such altered materials exhibits completely exceptional properties exploitable in a broad spectrum of industrially important applications ranging from catalysts up to health-care industry. Here we present unique approach for immobilization of electrochemically synthesized silver nanoparticles on polyethyleneterephthalate (PET) foil whose essence lies in physical incorporation of particles into thin polymer surface layer induced by polarized excimer laser light. Changes in chemical composition and surface structure of polymer after particle immobilization were recorded by wide range of analytical techniques such as ARXPS, EDX, RBS, AAS, Raman, ICP-MS, DLS, UV-vis, SEM, TEM, and AFM. Thorough analysis of both nanoparticles entering the immobilization step as well as modified PET surface allowed revealing the mechanism of immobilization process itself. Silver nanoparticles were physically embedded into a thin surface layer of polymer reaching several nanometers beneath the surface rather than chemically bonded to PET macromolecules. Laser-implanted nanoparticles open up new possibilities especially in the development of the next generation cell-conform antimicrobial coatings of polymeric materials, namely due to the considerable immobilization strength which is strong enough to prevent particle release into the surrounding environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dai, Guohong; Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Material Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201; School of Science, Nanchang University, Nanchang 330031
2013-11-07
We propose a convenient method to induce a uniaxial anisotropy in magnetostrictive Fe{sub 81}Ga{sub 19} films grown on flexible polyethylene terephthalate (PET) substrates by bending the substrate prior to deposition. A tensile/compressive stress is induced in the Fe{sub 81}Ga{sub 19} films when PET substrates are shaped from concave/convex to flat after deposition. The stressed Fe{sub 81}Ga{sub 19} films exhibit a significant uniaxial magnetic anisotropy due to the internal stress arising from changes in shape of PET substrates. The easy axis is along the tensile stress direction and the coercive field along easy axis is increased with increasing the internal tensilemore » stress. The remanence of hard axis is decreased with increasing the compressive stress, while the coercive field is almost unchanged. A modified Stoner-Wohlfarth model with considering the distribution of easy axes in polycrystalline films is used to account for the magnetic properties tuned by the strain-controlled magnetoelastic anisotropy in flexible Fe{sub 81}Ga{sub 19} films. Our investigations provide a convenient way to induce uniaxial magnetic anisotropy, which is particularly important for fabricating flexible magnetoelectronic devices.« less
Maximum likelihood positioning and energy correction for scintillation detectors
NASA Astrophysics Data System (ADS)
Lerche, Christoph W.; Salomon, André; Goldschmidt, Benjamin; Lodomez, Sarah; Weissler, Björn; Solf, Torsten
2016-02-01
An algorithm for determining the crystal pixel and the gamma ray energy with scintillation detectors for PET is presented. The algorithm uses Likelihood Maximisation (ML) and therefore is inherently robust to missing data caused by defect or paralysed photo detector pixels. We tested the algorithm on a highly integrated MRI compatible small animal PET insert. The scintillation detector blocks of the PET gantry were built with the newly developed digital Silicon Photomultiplier (SiPM) technology from Philips Digital Photon Counting and LYSO pixel arrays with a pitch of 1 mm and length of 12 mm. Light sharing was used to readout the scintillation light from the 30× 30 scintillator pixel array with an 8× 8 SiPM array. For the performance evaluation of the proposed algorithm, we measured the scanner’s spatial resolution, energy resolution, singles and prompt count rate performance, and image noise. These values were compared to corresponding values obtained with Center of Gravity (CoG) based positioning methods for different scintillation light trigger thresholds and also for different energy windows. While all positioning algorithms showed similar spatial resolution, a clear advantage for the ML method was observed when comparing the PET scanner’s overall single and prompt detection efficiency, image noise, and energy resolution to the CoG based methods. Further, ML positioning reduces the dependence of image quality on scanner configuration parameters and was the only method that allowed achieving highest energy resolution, count rate performance and spatial resolution at the same time.
Scharko, A M; Perlman, S B; Hinds PW2nd; Hanson, J M; Uno, H; Pauza, C D
1996-01-01
Pathogenesis of simian immunodeficiency virus (SIV) infection in rhesus macaques begins with acute viremia and then progresses to a distributed infection in the solid lymphoid tissues, which is followed by a process of cellular destruction leading to terminal disease and death. Blood and tissue specimens show the progress of infection at the cellular level but do not reveal the pattern of infection and host responses occurring throughout the body. The purpose of this investigation was to determine whether positron emission tomography (PET) imaging with intravenous 2-18F-2-deoxyglucose (FDG) could identify activated lymphoid tissues in a living animal and whether this pattern would reflect the extent of SIV infection. PET images from SIV-infected animals were distinguishable from uninfected controls and revealed a pattern consistent with widespread lymphoid tissue activation. Significant FDG accumulation in colon along with mesenteric and ileocaecal lymph nodes was found in SIV infection, especially during terminal disease stages. Areas of elevated FDG uptake in the PET images were correlated with productive SIV infection using in situ hybridization as a test for virus replication. PET-FDG images of SIV-infected animals correlated sites of virus replication with high FDG accumulation. These data show that the method can be used to evaluate the distribution and activity of infected tissues in a living animal without biopsy. Fewer tissues had high FDG uptake in terminal animals than midstage animals, and both were clearly distinguishable from uninfected animal scans. Images Fig. 1 Fig. 2 Fig. 3 PMID:8692831
Observation of fast scintillation of cryogenic PbI/sub 2/ with VLPCs
NASA Astrophysics Data System (ADS)
Moses, W. W.; Choong, W.-S.; Derenzo, S. E.; Bross, A. D.; Dysert, R.; Rykalin, V. V.; Shah, K. S.; Klugerman, M.
2004-10-01
At cryogenic temperatures (/spl sim/10 K), undoped lead iodide (PbI/sub 2/) has material and scintillation properties that are very attractive for positron emission tomography (PET). However, the PbI/sub 2/ emissions are quenched at temperatures >40 K, so close optical coupling between the scintillator and photodetector requires a photodetector that also operates at cryogenic temperatures. This suggests the visible light photon counter (VLPC), which operates at similar temperatures and combines high gain and high quantum efficiency. We proximity couple (0.001 in air gap) PbI/sub 2/ crystals with 1.0-2.5 mm dimensions to a 1 mm diameter VLPC and cool the system to 8.5 K. Signals with short (<10 ns) duration are observed. When excited with 511 keV photons, a coincidence timing resolution of 1.3 ns full-width at half-maximum is measured. While a clear photopeak is observed for 122 keV excitation, no clear photopeak is seen under 511 keV excitation (possibly due to the poor optical quality of the PbI/sub 2/ crystals). While the present configuration must be scaled-up considerably, a cryogenic PbI/sub 2//VLPC combination may eventually become the basis for a practical time-of-flight PET camera.
Holstila, Milja; Pesola, Marko; Saari, Teemu; Koskensalo, Kalle; Raiko, Juho; Borra, Ronald J H; Nuutila, Pirjo; Parkkola, Riitta; Virtanen, Kirsi A
2017-05-01
Brown adipose tissue (BAT) is compositionally distinct from white adipose tissue (WAT) in terms of triglyceride and water content. In adult humans, the most significant BAT depot is localized in the supraclavicular area. Our aim is to differentiate brown adipose tissue from white adipose tissue using fat T2* relaxation time mapping and signal-fat-fraction (SFF) analysis based on a commercially available modified 2-point-Dixon (mDixon) water-fat separation method. We hypothesize that magnetic resonance (MR) imaging can reliably measure BAT regardless of the cold-induced metabolic activation, with BAT having a significantly higher water and iron content compared to WAT. The supraclavicular area of 13 volunteers was studied on 3T PET-MRI scanner using T2* relaxation time and SFF mapping both during cold exposure and at ambient temperature; and 18 F-FDG PET during cold exposure. Volumes of interest (VOIs) were defined semiautomatically in the supraclavicular fat depot, subcutaneous WAT and muscle. The supraclavicular fat depot (assumed to contain BAT) had a significantly lower SFF and fat T2* relaxation time compared to subcutaneous WAT. Cold exposure did not significantly affect MR-based measurements. SFF and T2* values measured during cold exposure and at ambient temperature correlated inversely with the glucose uptake measured by 18 F-FDG PET. Human BAT can be reliably and safely assessed using MRI without cold activation and PET-related radiation exposure. Copyright © 2017 Elsevier Inc. All rights reserved.
Nakamura, Akihiro; Tanizaki, Yasuo; Takeuchi, Miho; Ito, Shigeru; Sano, Yoshitaka; Sato, Mayumi; Kanno, Toshihiko; Okada, Hiroyuki; Torizuka, Tatsuo; Nishizawa, Sadahiko
2014-06-01
While point spread function (PSF)-based positron emission tomography (PET) reconstruction effectively improves the spatial resolution and image quality of PET, it may damage its quantitative properties by producing edge artifacts, or Gibbs artifacts, which appear to cause overestimation of regional radioactivity concentration. In this report, we investigated how edge artifacts produce negative effects on the quantitative properties of PET. Experiments with a National Electrical Manufacturers Association (NEMA) phantom, containing radioactive spheres of a variety of sizes and background filled with cold air or water, or radioactive solutions, showed that profiles modified by edge artifacts were reproducible regardless of background μ values, and the effects of edge artifacts increased with increasing sphere-to-background radioactivity concentration ratio (S/B ratio). Profiles were also affected by edge artifacts in complex fashion in response to variable combinations of sphere sizes and S/B ratios; and central single-peak overestimation up to 50% was occasionally noted in relatively small spheres with high S/B ratios. Effects of edge artifacts were obscured in spheres with low S/B ratios. In patient images with a variety of focal lesions, areas of higher radioactivity accumulation were generally more enhanced by edge artifacts, but the effects were variable depending on the size of and accumulation in the lesion. PET images generated using PSF-based reconstruction are therefore not appropriate for the evaluation of SUV.
NASA Astrophysics Data System (ADS)
Faybishenko, B.; Flach, G. P.
2012-12-01
The objectives of this presentation are: (a) to illustrate the application of Monte Carlo and fuzzy-probabilistic approaches for uncertainty quantification (UQ) in predictions of potential evapotranspiration (PET), actual evapotranspiration (ET), and infiltration (I), using uncertain hydrological or meteorological time series data, and (b) to compare the results of these calculations with those from field measurements at the U.S. Department of Energy Savannah River Site (SRS), near Aiken, South Carolina, USA. The UQ calculations include the evaluation of aleatory (parameter uncertainty) and epistemic (model) uncertainties. The effect of aleatory uncertainty is expressed by assigning the probability distributions of input parameters, using historical monthly averaged data from the meteorological station at the SRS. The combined effect of aleatory and epistemic uncertainties on the UQ of PET, ET, and Iis then expressed by aggregating the results of calculations from multiple models using a p-box and fuzzy numbers. The uncertainty in PETis calculated using the Bair-Robertson, Blaney-Criddle, Caprio, Hargreaves-Samani, Hamon, Jensen-Haise, Linacre, Makkink, Priestly-Taylor, Penman, Penman-Monteith, Thornthwaite, and Turc models. Then, ET is calculated from the modified Budyko model, followed by calculations of I from the water balance equation. We show that probabilistic and fuzzy-probabilistic calculations using multiple models generate the PET, ET, and Idistributions, which are well within the range of field measurements. We also show that a selection of a subset of models can be used to constrain the uncertainty quantification of PET, ET, and I.
Polymeric nanoparticle PET/MR imaging allows macrophage detection in atherosclerotic plaques
Majmudar, Maulik D.; Yoo, Jeongsoo; Keliher, Edmund J.; Truelove, Jessica; Iwamoto, Yoshiko; Sena, Brena; Dutta, Partha; Borodovsky, Anna; Fitzgerald, Kevin; Di Carli, Marcelo; Libby, Peter; Anderson, Daniel G.; Swirski, Filip K.; Weissleder, Ralph; Nahrendorf, Matthias
2013-01-01
Rationale Myeloid cell content in atherosclerotic plaques associates with rupture and thrombosis. Thus, imaging of lesional monocyte and macrophages (Mo/Mϕ) could serve as a biomarker of disease progression and therapeutic intervention. Objective To noninvasively assess plaque inflammation with dextran nanoparticle-facilitated hybrid PET/MR imaging. Methods and Results Using clinically approved building blocks, we systematically developed 13nm polymeric nanoparticles consisting of crosslinked short chain dextrans which were modified with desferoxamine for zirconium-89 radiolabeling (89Zr-DNP) and a near infrared fluorochrome (VT680) for microscopic and cellular validation. Flow cytometry of cells isolated from excised aortas showed DNP uptake predominantly in Mo/Mϕ (76.7%) and lower signal originating from other leukocytes such as neutrophils and lymphocytes (11.8% and 0.7%, p<0.05 versus Mo/Mϕ). DNP colocalized with the myeloid cell marker CD11b on immunohistochemistry. PET/MRI revealed high uptake of 89Zr-DNP in the aortic root of ApoE−/− mice (standard uptake value, ApoE−/− mice versus wild type controls, 1.9±0.28 versus 1.3±0.03, p<0.05), corroborated by ex vivo scintillation counting and autoradiography. Therapeutic silencing of the monocyte-recruiting receptor CCR2 with siRNA decreased 89Zr-DNP plaque signal (p<0.05) and inflammatory gene expression (p<0.05). Conclusions Hybrid PET/MR imaging with a 13nm DNP enables noninvasive assessment of inflammation in experimental atherosclerotic plaques and reports on therapeutic efficacy of anti-inflammatory therapy. PMID:23300273
Polyurethane foams obtained from residues of PET manufacturing and modified with carbon nanotubes
NASA Astrophysics Data System (ADS)
Stiebra, L.; Cabulis, U.; Knite, M.
2016-04-01
In this work we report the preparation of rigid microcellular polyurethane/carbon nanotube nanocomposites with different CNT loadings (0.09-0.46%) and various isocyanate indexes (110-260). Water was used as a blowing agent for samples. Density of all obtained samples - 200 ± 10 kg/m3. Electrical properties, as well as heat conductivity, cellular structure and mechanical properties of these nanocomposites were investigated.
NASA Astrophysics Data System (ADS)
Tóth, A.; Veres, M.; Kereszturi, K.; Mohai, M.; Bertóti, I.; Szépvölgyi, J.
2011-10-01
The surfaces of untreated and helium plasma-based ion implantation (He PBII) treated poly(ethylene terephthalate) (PET) samples were characterised by reflectance colorimetry, contact angle studies and measurements of surface electrical resistance. The results were related to the structural and compositional data obtained by the authors earlier on parallel samples by XPS and Raman spectroscopy. Inverse correlations between lightness and ID/ IG ratio and between chroma and ID/ IG ratio were obtained, suggesting that the PBII-treated PET samples darken and their colourfulness decreases with the increase of the portion of aromatic sp 2 carbon rings in the chemical structure of the modified layer. Direct correlation between water contact angle and the ID/ IG ratio and inverse correlations between surface energy and ID/ IG ratio and between dispersive component of surface energy and ID/ IG ratio were found, reflecting that surface wettability, surface energy and its dispersive component decrease with the formation of surface structure, characterised again by enhanced portion of aromatic sp 2 carbon rings. The surface electrical resistance decreased with the increase of the surface C-content determined by XPS and also with the increase of the surface concentration of conjugated double bonds, reflected by the increase of the π → π* shake-up satellite of the C 1s peak.
Vladimir Kovalev; Cyle Wold; Alexander Petkov; Wei Min Hao
2011-01-01
We present a modified technique for processing multiangle lidar data that is applicable for relatively clear atmospheres, where the utilization of the conventional Kano-Hamilton method meets significant issues. Our retrieval algorithm allows computing the two-way transmission and the corresponding extinction-coefficient profile in any slope direction searched during...
Li, Mengmeng; Wang, Shiwen; Jiang, Jia; Sun, Jiashu; Li, Yuzhuo; Huang, Deyong; Long, Yun-Ze; Zheng, Wenfu; Chen, Shiyi; Jiang, Xingyu
2015-05-07
The Ligament Advanced Reinforcement System (LARS) has been considered as a promising graft for ligament reconstruction. To improve its biocompatibility and effectiveness on new bone formation, we modified the surface of a polyethylene terephthalate (PET) ligament with nanoscale silica using atom transfer radical polymerization (ATRP) and silica polymerization. The modified ligament is tested by both in vitro and in vivo experiments. Human osteoblast testing in vitro exhibits an ∼21% higher value in cell viability for silica-modified grafts compared with original grafts. Animal testing in vivo shows that there is new formed bone in the case of a nanoscale silica-coated ligament. These results demonstrate that our approach for nanoscale silica surface modification on LARS could be potentially applied for ligament reconstruction.
Blázquez, Ana B.; Berin, M. Cecilia
2016-01-01
Food allergy is a common disease affecting approximately 8% of children and 5% of adults. The prevalence has increased over the last two decades, suggesting an important environmental contribution to susceptibility. Studies have identified mode of birth, pet exposure, and having older siblings as being significant risk modifying factors in the development of food allergy. With the discovery that these factors significantly impact the composition of the intestinal microbiome, which is known to play a critical role in shaping the immune system, recent studies have begun to address the role of the intestinal microbiota in the development of food allergy. Studies in human cohorts support a dysbiosis in food allergy, and limited data suggest that this dysbiosis occurs early in life, preceding the onset of sensitization. Studies from animal models have clearly shown that the composition of the intestinal microbiota confers susceptibility to food allergy, and that there are organisms such as Clostridia species that are protective in the development of food allergy. Our understanding of microbial regulation of food allergy is in its nascency, but the state of the field supports an important contribution of intestinal microbes to susceptibility. Challenges going forward are to identify commensal-derived microorganisms that could be used therapeutically to prevent or perhaps treat food allergy. PMID:27686718
PET/CT imaging of clear cell renal cell carcinoma with 124I labeled chimeric antibody
Bahnson, Eamonn E.; Murrey, Douglas A.; Mojzisik, Cathy M.; Hall, Nathan C.; Martinez-Suarez, Humberto J.; Knopp, Michael V.; Martin, Edward W.; Povoski, Stephen P.; Bahnson, Robert R.
2009-01-01
Clear cell renal cell carcinoma (ccRCC) presents problems for urologists in diagnosis, treatment selection, intraoperative surgical margin analysis, and long term monitoring. In this paper we describe the development of a radiolabeled antibody specific to ccRCC (124I-cG250) and its potential to help urologists manage each of these problems. We believe 124I-cG250, in conjunction with perioperative Positron emission tomography/computed tomography imaging and intraoperative handheld gamma probe use, has the potential to diagnose ccRCC, aid in determining a proper course of treatment (operative or otherwise), confirm complete resection of malignant tissue in real time, and monitor patients post-operatively. PMID:21789055
A Lower-Cost High-Resolution LYSO Detector Development for Positron Emission Mammography (PEM)
Ramirez, Rocio A.; Zhang, Yuxuan; Liu, Shitao; Li, Hongdi; Baghaei, Hossain; An, Shaohui; Wang, Chao; Jan, Meei-Ling; Wong, Wai-Hoi
2010-01-01
In photomultiplier-quadrant-sharing (PQS) geometry for positron emission tomography applications, each PMT is shared by four blocks and each detector block is optically coupled to four round PMTs. Although this design reduces the cost of high-resolution PET systems, when the camera consists of detector panels that are made up of square blocks, half of the PMT’s sensitive window remains unused at the detector panel edge. Our goal was to develop a LYSO detector panel which minimizes the unused portion of the PMTs for a low-cost, high-resolution, and high-sensitivity positron emission mammography (PEM) camera. We modified the PQS design by using elongated blocks at panel edges and square blocks in the inner area. For elongated blocks, symmetric and asymmetrical reflector patterns were developed and PQS and PMT-half-sharing (PHS) arrangements were implemented in order to obtain a suitable decoding. The packing fraction was 96.3% for asymmetric block and 95.5% for symmetric block. Both of the blocks have excellent decoding capability with all crystals clearly identified, 156 for asymmetric and 144 for symmetric and peak-to-valley ratio of 3.0 and 2.3 respectively. The average energy resolution was 14.2% for the asymmetric block and 13.1% for the symmetric block. Using a modified PQS geometry and asymmetric block design, we reduced the unused PMT region at detector panel edges, thereby increased the field-of-view and the overall detection sensitivity and minimized the undetected breast region near the chest wall. This detector design and using regular round PMT allowed building a lower-cost, high-resolution and high-sensitivity PEM camera. PMID:20485510
From bench to pet shop to bedside? The environment and immune function in mice.
Kitching, A Richard; Ooi, Joshua D
2016-12-01
The generation of inbred mouse strains in the late 19th and early 20th centuries, coupled with the later establishment of specific pathogen-free animal research facilities created a powerful biological platform for exploration of the immune system in health and disease. Studies in this setting have been responsible for huge advances in our understanding of immunobiology and disease, including immune-mediated kidney disease. However, whereas this reductionist and relatively standardized approach allows us to make sense of complex disease biology, it takes place in controlled environments that clearly differ from those that we humans encounter in everyday life. Recent studies comparing the immune systems of wild mice, pet shop mice, and laboratory mice suggest ways in which the murine immune system can be influenced to behave more like the human immune system. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.
Kang, Jihoon; Choi, Yong
2016-07-01
Light sharing PET detector configuration coupled with thick light guide and Geiger-mode avalanche photodiode (GAPD) with large-area microcells was proposed to overcome the energy non-linearity problem and to obtain high light collection efficiency (LCE). A Monte-Carlo simulation was conducted for the three types of LSO block, 4 × 4 array of 3 × 3 × 20 mm(3) discrete crystals, 6 × 6 array of 2 × 2 × 20 mm(3) discrete crystals, and 12 × 12 array of 1 × 1 × 20 mm(3) discrete crystals, to investigate the scintillation light distribution after conversion of the γ-rays in LSO. The incident photons were read out by three types of 4 × 4 array photosensors, which were PSPMT of 25% quantum efficiency (QE), GAPD1 with 50 × 50 µm(2) microcells of 30% photon detection efficiency (PDE) and GAPD2 with 100 × 100 µm(2) of 45% PDE. The number of counted photons in each photosensor was analytically calculated. The LCE, linearity and flood histogram were examined for each PET detector module having 99 different configurations as a function of light guide thickness ranging from 0 to 10 mm. The performance of PET detector modules based on GAPDs was considerably improved by using the thick light guide. The LCE was increased from 24 to 30% and from 14 to 41%, and the linearity was also improved from 0.97 to 0.99 and from 0.75 to 0.99, for GAPD1 and GAPD2, respectively. As expected, the performance of PSPMT based detector did not change. The flood histogram of 12 × 12 array PET detector modules using 3 mm light guide coupled with GAPDs was obtained by simulation, and all crystals of 1 × 1 × 20 mm(3) size were clearly identified. PET detector module coupled with thick light guide and GAPD array with large-area microcells was proposed to obtain high QE and high spatial resolution, and its feasibility was verified. This study demonstrated that the overall PET performance of the proposed design was considerably improved, and this approach will provide opportunities to develop GAPD based PET detector with a high LCE. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Recovery and normalization of triple coincidences in PET.
Lage, Eduardo; Parot, Vicente; Moore, Stephen C; Sitek, Arkadiusz; Udías, Jose M; Dave, Shivang R; Park, Mi-Ae; Vaquero, Juan J; Herraiz, Joaquin L
2015-03-01
Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. To recover triple coincidences, the authors' method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. The addition of triple-coincidence events with the authors' method increased peak NEC rates of the scanner by 26.6% and 32% for mouse- and rat-sized objects, respectively. This increase in NEC-rate performance was also reflected in the image-quality metrics. Images reconstructed using double and triple coincidences recovered using their method had better signal-to-noise ratio than those obtained using only double coincidences, while preserving spatial resolution and contrast. Distribution of triple coincidences using an equal-weighting scheme increased apparent system sensitivity but degraded image quality. The performance boost provided by the inclusion of triple coincidences using their method allowed to reduce the acquisition time of standard imaging procedures by up to ∼25%. Recovering triple coincidences with the proposed method can effectively increase the sensitivity of current clinical and preclinical PET systems without compromising other parameters like spatial resolution or contrast.
System Performance Simulations of the RatCAP Awake Rat Brain Scanner
NASA Astrophysics Data System (ADS)
Shokouhi, S.; Vaska, P.; Schlyer, D. J.; Stoll, S. P.; Villanueva, A.; Kriplani, A.; Woody, C. L.
2005-10-01
The capability to create high quality images from data acquired by the Rat Conscious Animal PET tomograph (RatCAP) has been evaluated using modified versions of the PET Monte Carlo code Simulation System for Emission Tomography (SimSET). The proposed tomograph consists of lutetium oxyorthosilicate (LSO) crystals arranged in 12 4 /spl times/ 8 blocks. The effects of the RatCAPs small ring diameter (/spl sim/40 mm) and its block detector geometry on image quality for small animal studies have been investigated. Since the field of view will be almost as large as the ring diameter, radial elongation artifacts due to parallax error are expected to degrade the spatial resolution and thus the image quality at the edge of the field of view. In addition to Monte Carlo simulations, some preliminary results of experimentally acquired images in both two-dimensional (2-D) and 3-D modes are presented.
Exposure to cats: update on risks for sensitization and allergic diseases.
Dharmage, Shyamali C; Lodge, Caroline L; Matheson, Melanie C; Campbell, Brittany; Lowe, Adrian J
2012-10-01
Cats are the pets most commonly implicated in the etiology of asthma and allergic disease. However, systematic reviews have concluded that there is a lack of evidence to support the idea that cat exposure in early life increases the risk of allergic disease. Indeed, it appears most likely that cat exposure is protective against allergic diseases. Recent large prospective studies have shown that living with a cat during childhood, especially during the first year of a child's life, could be protective. However, any advice given to the parents should also incorporate how new acquisition of cats can affect other family members, especially those who are already sensitized. Research is urgently needed to determine whether the suggested impact of acquisition of cats in adult life is modified by the person's childhood pet ownership, to help parents who seek advice on whether or not to get a cat.
Longitudinal tau PET in ageing and Alzheimer’s disease
Jack, Clifford R; Wiste, Heather J; Schwarz, Christopher G; Lowe, Val J; Senjem, Matthew L; Vemuri, Prashanthi; Weigand, Stephen D; Therneau, Terry M; Knopman, Dave S; Gunter, Jeffrey L; Jones, David T; Graff-Radford, Jonathan; Kantarci, Kejal; Roberts, Rosebud O; Mielke, Michelle M; Machulda, Mary M; Petersen, Ronald C
2018-01-01
Abstract See Hansson and Mormino (doi:10.1093/brain/awy065) for a scientific commentary on this article. Our objective was to compare different whole-brain and region-specific measurements of within-person change on serial tau PET and evaluate its utility for clinical trials. We studied 126 individuals: 59 cognitively unimpaired with normal amyloid, 37 cognitively unimpaired with abnormal amyloid, and 30 cognitively impaired with an amnestic phenotype and abnormal amyloid. All had baseline amyloid PET and two tau PET, MRI, and clinical assessments. We compared the topography across all cortical regions of interest of tau PET accumulation rates and the rates of four different whole-brain or region-specific meta-regions of interest among the three clinical groups. We computed sample size estimates for change in tau PET, cortical volume, and memory/mental status indices for use as outcome measures in clinical trials. The cognitively unimpaired normal amyloid group had no observable tau accumulation throughout the brain. Tau accumulation rates in cognitively unimpaired abnormal amyloid were low [0.006 standardized uptake value ratio (SUVR), 0.5%, per year] but greater than rates in the cognitively unimpaired normal amyloid group in the basal and mid-temporal, retrosplenial, posterior cingulate, and entorhinal regions of interest. Thus, the earliest elevation in accumulation rates was widespread and not confined to the entorhinal cortex. Tau accumulation rates in the cognitively impaired abnormal amyloid group were 0.053 SUVR (3%) per year and greater than rates in cognitively unimpaired abnormal amyloid in all cortical areas except medial temporal. Rates of accumulation in the four meta-regions of interest differed but only slightly from one another. Among all tau PET meta-regions of interest, sample size estimates were smallest for a temporal lobe composite within cognitively unimpaired abnormal amyloid and for the late Alzheimer’s disease meta-region of interest within cognitively impaired abnormal amyloid. The ordering of the sample size estimates by outcome measure was MRI < tau PET < cognitive measures. At a group-wise level, observable rates of short-term serial tau accumulation were only seen in the presence of abnormal amyloid. As disease progressed to clinically symptomatic stages (cognitively impaired abnormal amyloid), observable rates of tau accumulation were seen uniformly throughout the brain providing evidence that tau does not accumulate in one area at a time or in start-stop, stepwise sequence. The information captured by rate measures in different meta-regions of interest, even those with little topographic overlap, was similar. The implication is that rate measurements from simple meta-regions of interest, without the need for Braak-like staging, may be sufficient to capture progressive within-person accumulation of pathologic tau. Tau PET SUVR measures should be an efficient outcome measure in disease-modifying clinical trials. PMID:29538647
Antimony leaching from polyethylene terephthalate (PET) plastic used for bottled drinking water.
Westerhoff, Paul; Prapaipong, Panjai; Shock, Everett; Hillaireau, Alice
2008-02-01
Antimony is a regulated contaminant that poses both acute and chronic health effects in drinking water. Previous reports suggest that polyethylene terephthalate (PET) plastics used for water bottles in Europe and Canada leach antimony, but no studies on bottled water in the United States have previously been conducted. Nine commercially available bottled waters in the southwestern US (Arizona) were purchased and tested for antimony concentrations as well as for potential antimony release by the plastics that compose the bottles. The southwestern US was chosen for the study because of its high consumption of bottled water and elevated temperatures, which could increase antimony leaching from PET plastics. Antimony concentrations in the bottled waters ranged from 0.095 to 0.521 ppb, well below the US Environmental Protection Agency (USEPA) maximum contaminant level (MCL) of 6 ppb. The average concentration was 0.195+/-0.116 ppb at the beginning of the study and 0.226+/-0.160 ppb 3 months later, with no statistical differences; samples were stored at 22 degrees C. However, storage at higher temperatures had a significant effect on the time-dependent release of antimony. The rate of antimony (Sb) release could be fit by a power function model (Sb(t)=Sb 0 x[Time, h]k; k=8.7 x 10(-6)x[Temperature ( degrees C)](2.55); Sb 0 is the initial antimony concentration). For exposure temperatures of 60, 65, 70, 75, 80, and 85 degrees C, the exposure durations necessary to exceed the 6 ppb MCL are 176, 38, 12, 4.7, 2.3, and 1.3 days, respectively. Summertime temperatures inside of cars, garages, and enclosed storage areas can exceed 65 degrees C in Arizona, and thus could promote antimony leaching from PET bottled waters. Microwave digestion revealed that the PET plastic used by one brand contained 213+/-35 mgSb/kg plastic; leaching of all the antimony from this plastic into 0.5L of water in a bottle could result in an antimony concentration of 376 ppb. Clearly, only a small fraction of the antimony in PET plastic bottles is released into the water. Still, the use of alternative types of plastics that do not leach antimony should be considered, especially for climates where exposure to extreme conditions can promote antimony release from PET plastics.
Blocker, Stephanie J; Douglas, Kirk A; Polin, Lisa Anne; Lee, Helen; Hendriks, Bart S; Lalo, Enxhi; Chen, Wei; Shields, Anthony F
2017-01-01
Liposomes (LP) deliver drug to tumors due to enhanced permeability and retention (EPR). LP were labeled with 64 Cu for positron emission tomography (PET) to image tumor localization. Bevacizumab (bev), a VEGF targeted antibody, may modify LP delivery by altering tumor EPR and this change can also be imaged. Objective : Assess the utility of 64 Cu-labeled LP for PET in measuring altered LP delivery early after treatment with bev. Methods: HT-29 human colorectal adenocarcinoma tumors were grown subcutaneously in SCID mice. Empty LP MM-DX-929 (Merrimack Pharmaceuticals, Inc. Cambridge, MA) were labeled with 64 CuCl 2 chelated with 4-DEAP-ATSC. Tumor-bearing mice received ~200-300 μCi of 64 Cu-MM-DX-929 and imaged with microPET. All mice were scanned before and after the treatment period, in which half of the mice received bev for one week. Scans were compared for changes in LP accumulation during this time. Initially, tissues were collected after the second PET for biodistribution measurements and histological analysis. Subsequent groups were divided for further treatment. Tumor growth following bev treatment, with or without LP-I, was assessed compared to untreated controls. Results : PET scans of untreated mice showed increased uptake of 64 Cu-MM-DX-929, with a mean change in tumor SUV max of 43.9%±6.6% (n=10) after 7 days. Conversely, images of treated mice showed that liposome delivery did not increase, with changes in SUV max of 7.6%±4.8% (n=12). Changes in tumor SUV max were significantly different between both groups (p=0.0003). Histology of tumor tissues indicated that short-term bev was able to alter vessel size. Therapeutically, while bev monotherapy, LP-I monotherapy, and treatment with bev followed by LP-I all slowed HT-29 tumor growth compared to controls, combination provided no therapeutic benefit. Conclusions: PET with tracer LP 64 Cu-MM-DX-929 can detect significant differences in LP delivery to colon tumors treated with bev when compared to untreated controls. Imaging with 64 Cu-MM-DX-929 is sensitive enough to measure drug-induced changes in LP localization which can have an effect on outcomes of treatment with LP.
64Cu-Labeled LyP-1-Dendrimer for PET-CT Imaging of Atherosclerotic Plaque
2015-01-01
The ability to detect and quantify macrophage accumulation can provide important diagnostic and prognostic information for atherosclerotic plaque. We have previously shown that LyP-1, a cyclic 9-amino acid peptide, binds to p32 proteins on activated macrophages, facilitating the visualization of atherosclerotic plaque with PET. Yet, the in vivo plaque accumulation of monomeric [18F]FBA-LyP-1 was low (0.31 ± 0.05%ID/g). To increase the avidity of LyP-1 constructs to p32, we synthesized a dendritic form of LyP-1 on solid phase using lysine as the core structural element. Imaging probes (FAM or 6-BAT) were conjugated to a lysine or cysteine on the dendrimer for optical and PET studies. The N-terminus of the dendrimer was further modified with an aminooxy group in order to conjugate LyP-1 and ARAL peptides bearing a ketone. Oxime ligation of peptides to both dendrimers resulted in (LyP-1)4- and (ARAL)4-dendrimers with optical (FAM) and PET probes (6-BAT). For PET-CT studies, (LyP-1)4- and (ARAL)4-dendrimer-6-BAT were labeled with 64Cu (t1/2 = 12.7 h) and intravenously injected into the atherosclerotic (ApoE–/–) mice. After two hours of circulation, PET-CT coregistered images demonstrated greater uptake of the (LyP-1)4-dendrimer-64Cu than the (ARAL)4-dendrimer-64Cu in the aortic root and descending aorta. Ex vivo images and the biodistribution acquired at three hours after injection also demonstrated a significantly higher uptake of the (LyP-1)4-dendrimer-64Cu (1.1 ± 0.26%ID/g) than the (ARAL)4-dendrimer-64Cu (0.22 ± 0.05%ID/g) in the aorta. Similarly, subcutaneous injection of the LyP-1-dendrimeric carriers resulted in preferential accumulation in plaque-containing regions over 24 h. In the same model system, ex vivo fluorescence images within aortic plaque depict an increased accumulation and penetration of the (LyP-1)4-dendrimer-FAM as compared to the (ARAL)4-dendrimer-FAM. Taken together, the results suggest that the (LyP-1)4-dendrimer can be applied for in vivo PET imaging of plaque and that LyP-1 could be further exploited for the delivery of therapeutics with multivalent carriers or nanoparticles. PMID:24433095
Recyclability assessment of nano-reinforced plastic packaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sánchez, C., E-mail: csanchez@itene.com; Hortal, M., E-mail: mhortal@itene.com; Aliaga, C., E-mail: caliaga@itene.com
2014-12-15
Highlights: • The study compares the recyclability of polymers with and without nanoparticles. • Visual appearance, material quality and mechanical properties are evaluated. • Minor variations in mechanical properties in R-PE and R-PP with nanoparticles. • Slight degradation of R-PET which affect mechanical properties. • Colour deviations in recycled PE, PP and PET in ranges higher that 0.3 units. - Abstract: Packaging is expected to become the leading application for nano-composites by 2020 due to the great advantages on mechanical and active properties achieved with these substances. As novel materials, and although there are some current applications in the market,more » there is still unknown areas under development. One key issue to be addressed is to know more about the implications of the nano-composite packaging materials once they become waste. The present study evaluates the extrusion process of four nanomaterials (Layered silicate modified nanoclay (Nanoclay1), Calcium Carbonate (CaCO{sub 3}), Silver (Ag) and Zinc Oxide (ZnO) as part of different virgin polymer matrices of polyethylene (PE), Polypropylene (PP) and Polyethyleneterephtalate (PET). Thus, the following film plastic materials: (PE–Nanoclay1, PE–CaCO{sub 3}, PP–Ag, PET–ZnO, PET–Ag, PET–Nanoclay1) have been processed considering different recycling scenarios. Results on recyclability show that for PE and PP, in general terms and except for some minor variations in yellowness index, tensile modulus, tensile strength and tear strength (PE with Nanoclay1, PP with Ag), the introduction of nanomaterial in the recycling streams for plastic films does not affect the final recycled plastic material in terms of mechanical properties and material quality compared to conventional recycled plastic. Regarding PET, results show that the increasing addition of nanomaterial into the recycled PET matrix (especially PET–Ag) could influence important properties of the recycled material, due to a slight degradation of the polymer, such as increasing pinholes, degradation fumes and elongation at break. Moreover, it should be noted that colour deviations were visible in most of the samples (PE, PP and PET) in levels higher than 0.3 units (limit perceivable by the human eye). The acceptance of these changes in the properties of recycled PE, PP and PET will depend on the specific applications considered (e.g. packaging applications are more strict in material quality that urban furniture or construction products)« less
The Evaluation of Jet Injection for use in Veterinary Medicine,
1976-05-01
therapeutic drugs. As the demand for food animal protein increases and as pet aninal populations increase, technical advances into more advantageous methods of...general areas at the present time. 1) As society’s demand for meat protein increases, mass production methods will become increasingly necessary in...vaccine, modified live virus, bovine t.nsue culture ’rigin, Leptospira pomona bacterin, Anciv- :;.erum Co., Division of Phillips Roxane, St. Toseph, Mo
Fluid and Electrolyte Therapy During Vomiting and Diarrhea.
Tello, Luis; Perez-Freytes, Rossana
2017-03-01
Fluid therapy is generally the most life saving and important therapeutic measure in a critical pet suffering from dehydration due to gastrointestinal losses (vomiting and/or diarrhea). Fluid therapy should be personalized to the patient's history, complaint, physical examination and laboratory findings. It is directed to the patients needs and modified based of the physical and laboratory findings until fluid therapy resuscitation end points are achieved. Copyright © 2016 Elsevier Inc. All rights reserved.
Thoen, Hendrik; Keereman, Vincent; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan
2013-09-21
The optimization of a whole-body PET system remains a challenging task, as the imaging performance is influenced by a complex interaction of different design parameters. However, it is not always clear which parameters have the largest impact on image quality and are most eligible for optimization. To determine this, we need to be able to assess their influence on image quality. We performed Monte-Carlo simulations of a whole-body PET scanner to predict the influence on image quality of three detector parameters: the TOF resolution, the transverse pixel size and depth-of-interaction (DOI)-correction. The inner diameter of the PET scanner was 65 cm, small enough to allow physical integration into a simultaneous PET-MR system. Point sources were used to evaluate the influence of transverse pixel size and DOI-correction on spatial resolution as function of radial distance. To evaluate the influence on contrast recovery and pixel noise a cylindrical phantom of 35 cm diameter was used, representing a large patient. The phantom contained multiple hot lesions with 5 mm diameter. These lesions were placed at radial distances of 50, 100 and 150 mm from the center of the field-of-view, to be able to study the effects at different radial positions. The non-prewhitening (NPW) observer was used for objective analysis of the detectability of the hot lesions in the cylindrical phantom. Based on this analysis the NPW-SNR was used to quantify the relative improvements in image quality due to changes of the variable detector parameters. The image quality of a whole-body PET scanner can be improved significantly by reducing the transverse pixel size from 4 to 2.6 mm and improving the TOF resolution from 600 to 400 ps and further from 400 to 200 ps. Compared to pixel size, the TOF resolution has the larger potential to increase image quality for the simulated phantom. The introduction of two layer DOI-correction only leads to a modest improvement for the spheres at radial distance of 150 mm from the center of the transaxial FOV.
Jin, Zhao-Hui; Furukawa, Takako; Claron, Michael; Boturyn, Didier; Coll, Jean-Luc; Fukumura, Toshimitsu; Fujibayashi, Yasuhisa; Dumy, Pascal; Saga, Tsuneo
2012-12-01
64Cu-cyclam-RAFT-c(-RGDfK-)4 is a novel multimeric positron emission tomography (PET) probe for αVβ3 integrin imaging. Its uptake and αVβ3 expression in tumors showed a linear correlation. Since αVβ3 integrin is strongly expressed on activated endothelial cells during angiogenesis, we aimed to determine whether 64Cu-cyclam-RAFT-c(-RGDfK-)4 PET can be used to image tumor angiogenesis and monitor the antiangiogenic effect of a novel multi-targeted tyrosine kinase inhibitor, TSU-68. Athymic nude mice bearing human hepatocellular carcinoma HuH-7 xenografts, which expressed negligible αVβ3 levels on the tumor cells, received intraperitoneal injections of TSU-68 or the vehicle for 14 days. Antiangiogenic effects were determined at the end of therapy in terms of 64Cu-cyclam-RAFT-c(-RGDfK-)4 uptake evaluated using PET, biodistribution assay, and autoradiography, and they were compared with microvessel density (MVD) determined by CD31 immunostaining. 64Cu-cyclam-RAFT-c(-RGDfK-)4 PET enabled clear tumor visualization by targeting the vasculature, and the biodistribution assay indicated high tumor-to-blood and tumor-to-muscle ratios of 31.6 ± 6.3 and 6.7 ± 1.1, respectively, 3 h after probe injection. TSU-68 significantly slowed tumor growth and reduced MVD; these findings were consistent with a significant reduction in the tumor 64Cu-cyclam-RAFT-c(-RGDfK-)4 uptake. Moreover, a linear correlation was observed between tumor MVD and the corresponding standardized uptake value (SUV) (r = 0.829, P = 0.011 for SUV(mean); r = 0.776, P = 0.024 for SUV(max)) determined by quantitative PET. Autoradiography and immunostaining showed that the distribution of intratumoral radioactivity and tumor vasculature corresponded. We concluded that 64Cu-cyclam-RAFT-c(-RGDfK-)4 PET can be used for in vivo angiogenesis imaging and monitoring of tumor response to antiangiogenic therapy.
A microvascular compartment model validated using 11C-methylglucose liver PET in pigs
NASA Astrophysics Data System (ADS)
Munk, Ole L.; Keiding, Susanne; Baker, Charles; Bass, Ludvik
2018-01-01
The standard compartment model (CM) is widely used to analyse dynamic PET data. The CM is fitted to time-activity curves to estimate rate constants that describe the transport of a tracer between well-mixed compartments. The aim of this study was to develop and validate a more realistic microvascular compartment model (MCM) that includes capillary tracer concentration gradients, backflux from cells into the perfused capillaries and multiple re-uptakes during the passage through a capillary. The MCM incorporates only parameters with clear physiological meaning, it is easy to implement, and it does not require numerical solution. We compared the MCM and CM for the analysis of 3 min dynamic PET data of pig livers (N = 5) following injection of 11C-methylglucose. During PET scans, the tracer concentrations in blood were measured in the abdominal aorta, portal vein and liver vein by manual sampling. We found that the MCM outperformed the CM and that dynamic PET data include information which cannot be extracted using standard CM. The MCM fitted dynamic PET data better than the CM (Akaike values were 46 ± 4 for best MCM fits, and 82 ± 8 for best CM fits; mean ± standard deviation) and extracted physiologically reasonable parameter estimates such as blood perfusion that were in agreement with independent measurements. The difference between model-independent perfusion estimates and the best MCM perfusion estimates was -0.01 ± 0.05 ml/ml/min, whereas the difference was 0.30 ± 0.13 ml/ml/min using the CM. In addition, the MCM predicted the time course of concentrations in the liver vein, a prediction fundamentally unobtainable using the CM as it does not return tracer backflux from cells to capillary blood. The results demonstrate the benefit of using models that include more physiology and that models including concentration gradients should be preferred when analysing the blood-cell exchange of any tracer in any capillary bed.
Kidera, Daisuke; Kihara, Ken; Akamatsu, Go; Mikasa, Shohei; Taniguchi, Takafumi; Tsutsui, Yuji; Takeshita, Toshiki; Maebatake, Akira; Miwa, Kenta; Sasaki, Masayuki
2016-02-01
The aim of this study was to quantitatively evaluate the edge artifacts in PET images reconstructed using the point-spread function (PSF) algorithm at different sphere-to-background ratios of radioactivity (SBRs). We used a NEMA IEC body phantom consisting of six spheres with 37, 28, 22, 17, 13 and 10 mm in inner diameter. The background was filled with (18)F solution with a radioactivity concentration of 2.65 kBq/mL. We prepared three sets of phantoms with SBRs of 16, 8, 4 and 2. The PET data were acquired for 20 min using a Biograph mCT scanner. The images were reconstructed with the baseline ordered subsets expectation maximization (OSEM) algorithm, and with the OSEM + PSF correction model (PSF). For the image reconstruction, the number of iterations ranged from one to 10. The phantom PET image analyses were performed by a visual assessment of the PET images and profiles, a contrast recovery coefficient (CRC), which is the ratio of SBR in the images to the true SBR, and the percent change in the maximum count between the OSEM and PSF images (Δ % counts). In the PSF images, the spheres with a diameter of 17 mm or larger were surrounded by a dense edge in comparison with the OSEM images. In the spheres with a diameter of 22 mm or smaller, an overshoot appeared in the center of the spheres as a sharp peak in the PSF images in low SBR. These edge artifacts were clearly observed in relation to the increase of the SBR. The overestimation of the CRC was observed in 13 mm spheres in the PSF images. In the spheres with a diameter of 17 mm or smaller, the Δ % counts increased with an increasing SBR. The Δ % counts increased to 91 % in the 10-mm sphere at the SBR of 16. The edge artifacts in the PET images reconstructed using the PSF algorithm increased with an increasing SBR. In the small spheres, the edge artifact was observed as a sharp peak at the center of spheres and could result in overestimation.
Recent trends in soft-tissue infection imaging.
Petruzzi, Nicholas; Shanthly, Nylla; Thakur, Mathew
2009-03-01
This article discusses the current techniques and future directions of infection imaging with particular attention to respiratory, central nervous system, abdominal, and postoperative infections. The agents currently in use localize to areas of infection and inflammation. An infection-specific imaging agent would greatly improve the utility of scintigraphy in imaging occult infections. The superior spatial resolution of (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG-PET) and its lack of reliance on a functional immune system, gives this agent certain advantages over the other radiopharmaceuticals. In respiratory tract infection imaging, an important advancement would be the ability to quantitatively delineate lung inflammation, allowing one to monitor the therapeutic response in a variety of conditions. Current studies suggest PET should be considered the most accurate quantitative method. Scintigraphy has much to offer in localizing abdominal infection as well as inflammation. We may begin to see a gradual increase in the usage of (18)F-FDG-PET in detecting occult abdominal infections. Commonly used modalities for imaging inflammatory bowel disease are scintigraphy with (111)In-oxine/(99m)Tc-HMPAO labeled autologous white blood cells. The literature on central nervous system infection imaging is relatively scarce. Few clinical studies have been performed and numerous new agents have been developed for this use with varying results. Further studies are needed to more clearly delineate the future direction of this field. In evaluating the postoperative spine, (99m)Tc-ciprofloxacin single-photon emission computed tomography (SPECT) was reported to be >80% sensitive in patients more than 6 months after surgery. FDG-PET has also been suggested for this purpose and may play a larger role than originally thought. It appears PET/computed tomography (CT) is gaining support, especially in imaging those with fever of unknown origin or nonfunctional immune systems. Although an infection-specific agent is lacking, the development of one would greatly advance our ability to detect, localize, and quantify infections. Overall, imaging such an agent via SPECT/CT or PET/CT will pave the way for greater clinical reliability in the localization of infection.
18F-FDG PET/CT in gastric MALT lymphoma: a bicentric experience.
Albano, Domenico; Bertoli, Mattia; Ferro, Paola; Fallanca, Federico; Gianolli, Luigi; Picchio, Maria; Giubbini, Raffaele; Bertagna, Francesco
2017-04-01
The role of 18F-FDG-PET/CT in evaluating gastric MALT lymphoma is still controversial. In the literature the detection rate of 18F-FDG-PET/CT in patients with gastric MALT lymphoma is variable, and the reason for this heterogeneity is not still clear. Our aim was to investigate the particular metabolic behavior of these lymphoma. Sixty-nine patients (26 female, 43 male) with histologically confirmed gastric MALT lymphoma who underwent a 18F-FDG-PET/CT for initial staging from two centers were included. The PET images were analyzed visually and semi-quantitatively by measuring the maximum standardized uptake value (SUVmax), lesion-to-liver SUVmax ratio, and lesion-to-blood pool SUVmax ratio and compared with Ann Arbor stage, epidemiological (age, sex), histological (presence of gastritis, ulcer, H. pylori infection, plasmacytic differentiation, Ki-67 index), and morphological (tumor size, superficial lesions or mass-forming) characteristics. Thirty-six patients (52 %) had positive PET/CT (average SUVmax was 9±6.7; lesion-to-liver SUVmax ratio 3.7±2.6, lesion-to-blood pool SUVmax ratio 4.8±3.3) at the corresponding gastric lesion; the remaining 33 were not 18F-FDG-avid. In the univariate analysis, 18F-FDG avidity was significantly associated with morphological features (mass forming p<0.001 and high maximum diameter p<0.001), Ann Arbor stage (p=0.010), and Ki67 index (p<0.001) and not correlated with age, sex, presence of gastritis, ulcer, Helicobacter pylori infection, and plasmacytic differentiation. In the multivariate analysis, the correlations with gross morphological appearance, Ann Arbor stage, and Ki-67 score were confirmed. SUVmax, lesion-to-liver SUVmax ratio, and lesion-to-blood pool SUVmax ratio correlated significantly only with Ki67 index (p=0.047; p=0.012; p=0.042). 18F-FDG avidity was noted in 52 % of gastric MALT lymphoma and this avidity is correlated with gross morphological characteristics, tumor stage, and Ki-67 index. SUVmax, lesion-to-liver SUVmax ratio, and lesion-to-blood pool SUVmax ratio are correlated only with Ki-67 index, and only lesion-to-liver SUVmax ratio was independently associated with Ki-67 score.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kanoun, Salim, E-mail: Salim.kanoun@gmail.com; LE2I UMR6306, Centre national de la recherche scientifique, Arts et Métiers, Université Bourgogne Franche-Comté, Dijon; MRI Unit, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon
Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence.more » Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.« less
Behavioral and Self-report Measures Influencing Children’s Reported Attachment to Their Dog
Hall, Nathaniel J.; Liu, Jingwen; Kertes, Darlene A.; Wynne, Clive D.L.
2016-01-01
Despite the prevalence of dogs as family pets and increased scientific interest in canine behavior, few studies have investigated characteristics of the child or dog that influence the child-dog relationship. In the present study, we explored how behavioral and self-report measures influence a child’s reported feelings of attachment to their dog, as assessed by the Lexington Attachment to Pets Scale (LAPS). We tested specifically whether children (N= 99; Age: M= 10.25 years, SD= 1.31 years) reported stronger attachment to dogs that were perceived as being more supportive (measured by a modified version of the Network of Relationships Inventory), to dogs that are more successful in following the child’s pointing gesture in a standard two-object choice test, or to dogs that solicited more petting in a sociability assessment. In addition, we assessed whether children’s attachment security to their parent, and whether being responsible for the care of their dog, influenced reported feelings of attachment to the dog. Overall, perceived support provided by the dog was highly predictive of all subscales of the LAPS. The dog’s success in following the child’s pointing gesture and lower rates of petting during the sociability assessment were associated with higher ratings on the general attachment subscale of the LAPS, but not of other subscales of the LAPS. Caring for the dog did not predict the child’s reported attachment to dog, but did predict the dog’s behavior on the point following task and petting during the sociability task. If the child cared for the dog, the dog was more likely to be successful on the pointing task and more likely to be petted. These results indicate a dyadic relationship in which the child’s care for the dog is associated with the dog’s behavior on the behavioral tasks, which in turn is related to the child’s reported feelings of attachment. The direction of influence and nature of this dyad will be a fruitful area for future research. PMID:28066130
Merrill, David A; Siddarth, Prabha; Raji, Cyrus A; Emerson, Natacha D; Rueda, Florangel; Ercoli, Linda M; Miller, Karen J; Lavretsky, Helen; Harris, Laurel M; Burggren, Alison C; Bookheimer, Susan Y; Barrio, Jorge R; Small, Gary W
2016-09-01
Exercise and diet impact body composition, but their age-related brain effects are unclear at the molecular imaging level. To address these issues, the authors determined whether body mass index (BMI), physical activity, and diet relate to brain positron emission tomography (PET) of amyloid plaques and tau tangles using 2-(1-(6-[(2-[F-18]fluoroethyl)(methyl)amino]-2-naphthyl)ethylidene)malononitrile (FDDNP). Volunteers (N = 44; mean age: 62.6 ± 10.7 years) with subjective memory impairment (N = 24) or mild cognitive impairment (MCI; N = 20) were recruited by soliciting for memory complaints. Levels of physical activity and extent of following a Mediterranean-type diet were self-reported. FDDNP-PET scans assessed plaque/tangle binding in Alzheimer disease-associated regions (frontal, parietal, medial and lateral temporal, posterior cingulate). Mixed models controlling for known covariates examined BMI, physical activity, and diet in relation to FDDNP-PET. MCI subjects with above normal BMI (>25) had higher FDDNP-PET binding compared with those with normal BMI (1.11(0.03) versus 1.08(0.03), ES = 1.04, t(35) = 3.3, p = 0.002). Greater physical activity was associated with lower FDDNP-PET binding in MCI subjects (1.07(0.03) versus 1.11(0.03), ES = 1.13, t(35) = -3.1, p = 0.004) but not in subjects with subjective memory impairment (1.07(0.03) versus 1.07(0.03), ES = 0.02, t(35) = -0.1, p = 0.9). Healthier diet related to lower FDDNP-PET binding, regardless of cognitive status (1.07(0.03) versus 1.09(0.02), ES = 0.72, t(35) = -2.1, p = 0.04). These preliminary findings are consistent with a relationship between risk modifiersand brain plaque/tangle deposition in nondemented individuals and supports maintenance of normal body weight, regular physical activity, and healthy diet to protect the brain during aging. (clinicaltrials.gov; NCT00355498). Copyright © 2016 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.
Ma, Yan; Shao, Xiaonan
2017-12-01
Uterine fibroids are the most common pelvic solid tumors and common to 25% of women. F-fluorodexyglucose (F-FDG) is an energy metabolism tracer. Although FDG is generally concentrated in malignant lesions with high glucose metabolism, it can also accumulate in normal tissues, benign lesions, and inflammatory sites. The exact mechanism of FDG uptake by uterine fibroids is not clear. Here, we report a case of uterine fibroids with positive F-FDG positron emission tomography/computed tomography (PET/CT) imaging and significantly increased CA19-9. The patient was a 43-year-old woman and admitted to our hospital because of "1-year-extended menstrual periods." At admission, she had normal CA125, AFP, and CEA level and CA19-9>1000.00 U/mL. Gynecological transvaginal ultrasound found enlarged uterus with an anterior hypoechoic area of 3.9 × 4.2 cm. CT and contrast-enhanced CT showed significantly enhanced mass shadow on the left anterior wall of uterus. F-FDG PET/CT showed increased FDG metabolism of tumor in the anterior wall of the uterus. Laparoscopic hysterectomy was performed. Pathological examination demonstrated subserosal leiomyoma. Her CA19-9 level dropped to 91.50 U/mL 1 day after surgery. Significantly elevated CA19-9 was positioned in the uterus by PET/CT imaging, which not only avoided unnecessary gastrointestinal endoscopy and reduced the suffering of patients, but also strengthened the operation confidence in gynecologists. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Čepa, Adam; Ráliš, Jan; Král, Vlastimil; Paurová, Monika; Kučka, Jan; Humajová, Jana; Lázníček, Milan; Lebeda, Ondřej
2018-03-01
Specific oncology diagnostics requires new types of the selective radiopharmaceuticals, particularly those suitable for the molecular PET imaging. The aim of this work is to present a new, specific PET-immunodiagnostic radiopharmaceutical based on the monoclonal antibody IgG M75 targeting human carbonic anhydrase IX labelled with 64 Cu (T ½ = 12.70h) and its in vitro and in vivo evaluation. The antibody IgG M75 was conjugated with a non-commercial copper-specific chelator "phosphinate" and then labelled with the positron emitter 64 Cu. Stability of the labelled conjugated was tested in human serum. The immunoreactivity of the labelled conjugate was evaluated in vitro on a suitable cell cultures of the colorectal carcinoma (HT-29) and its imaging properties were estimated in vivo on a mouse model with inoculated colorectal carcinoma HT-29 imaged on a µPET/CT. The tested radioimmunoconjugate was obtained in a specific activity of 0.25-0.5 MBq/µg. In vitro uptake experiments revealed specific binding to the HT-29 cells (45 ± 2.8% of the total added activity) and the measured K D value was found to be 9.2nM. Imaging clearly demonstrated significant uptake of the labelled monoclonal antibody in the tumour at 18h post administration. The radioimmunoconjugate 64 Cu-PS-IgG M75 seems to be a suitable candidate for PET diagnostics of hypoxic tumours expressing human carbonic anhydrase IX. Copyright © 2017 Elsevier Ltd. All rights reserved.
Weiss, Ido D; Huff, Lyn M; Evbuomwan, Moses O; Xu, Xin; Dang, Hong Duc; Velez, Daniel S; Singh, Satya P; Zhang, Hongwei H; Gardina, Paul J; Lee, Jae-Ho; Lindenberg, Liza; Myers, Timothy G; Paik, Chang H; Schrump, David S; Pittaluga, Stefania; Choyke, Peter L; Fojo, Tito; Farber, Joshua M
2017-09-26
Expression of the chemokine receptor CXCR4 by many cancers correlates with aggressive clinical behavior. As part of the initial studies in a project whose goal was to quantify CXCR4 expression on cancers non-invasively, we examined CXCR4 expression in cancer samples by immunohistochemistry using a validated anti-CXCR4 antibody. Among solid tumors, we found expression of CXCR4 on significant percentages of major types of kidney, lung, and pancreatic adenocarcinomas, and, notably, on metastases of clear cell renal cell carcinoma and squamous cell carcinoma of the lung. We found particularly high expression of CXCR4 on adrenocortical cancer (ACC) metastases. Microarrays of ACC metastases revealed correlations between expression of CXCR4 and other chemokine system genes, particularly CXCR7/ACKR3 , which encodes an atypical chemokine receptor that shares a ligand, CXCL12, with CXCR4. A first-in-human study using 64 Cu-plerixafor for PET in an ACC patient prior to resection of metastases showed heterogeneity among metastatic nodules and good correlations among PET SUVs, CXCR4 staining, and CXCR4 mRNA. Additionally, we were able to show that CXCR4 expression correlated with the rates of growth of the pulmonary lesions in this patient. Further studies are needed to understand better the role of CXCR4 in ACC and whether targeting it may be beneficial. In this regard, non-invasive methods for assessing CXCR4 expression, such as PET using 64 Cu-plerixafor, should be important investigative tools.
Mokaleng, Botshelo B.; Ebenhan, Thomas; Ramesh, Suhas; Govender, Thavendran; Kruger, Hendrik G.; Hazari, Puja P.; Mishra, Anil K.; Marjanovic-Painter, Biljana; Zeevaart, Jan R.; Sathekge, Mike M.
2015-01-01
Noninvasive imaging is a powerful tool for early diagnosis and monitoring of various disease processes, such as infections. An alarming shortage of infection-selective radiopharmaceuticals exists for overcoming the diagnostic limitations with unspecific tracers such as 67/68Ga-citrate or 18F-FDG. We report here TBIA101, an antimicrobial peptide derivative that was conjugated to DOTA and radiolabeled with 68Ga for a subsequent in vitro assessment and in vivo infection imaging using Escherichia coli-bearing mice by targeting bacterial lipopolysaccharides with PET/CT. Following DOTA-conjugation, the compound was verified for its cytotoxic and bacterial binding behaviour and compound stability, followed by 68Gallium-radiolabeling. µPET/CT using 68Ga-DOTA-TBIA101 was employed to detect muscular E. coli-infection in BALB/c mice, as warranted by the in vitro results. 68Ga-DOTA-TBIA101-PET detected E. coli-infected muscle tissue (SUV = 1.3–2.4) > noninfected thighs (P = 0.322) > forearm muscles (P = 0.092) > background (P = 0.021) in the same animal. Normalization of the infected thigh muscle to reference tissue showed a ratio of 3.0 ± 0.8 and a ratio of 2.3 ± 0.6 compared to the identical healthy tissue. The majority of the activity was cleared by renal excretion. The latter findings warrant further preclinical imaging studies of greater depth, as the DOTA-conjugation did not compromise the TBIA101's capacity as targeting vector. PMID:25699267
Daumar, Pierre; Zeglis, Brian M.; Ramos, Nicholas; Divilov, Vadim; Sevak, Kuntal Kumar; Pillarsetty, NagaVaraKishore; Lewis, Jason S.
2015-01-01
Type II topoisomerase (Topo-II) is an ATP-dependent enzyme that is essential in the transcription, replication, and chromosome segregation processes and, as such, represents an attractive target for cancer therapy. Numerous studies indicate that the response to treatment with Topo-II inhibitors is highly dependent on both the levels and the activity of the enzyme. Consequently, a non-invasive assay to measure tumoral Topo-II levels has the potential to differentiate responders from non-responders. With the ultimate goal of developing a radiofluorinated tracer for positron emission tomography (PET) imaging, we have designed, synthesized, and evaluated a set of fluorinated compounds based on the structure of the ATP-competitive Topo-II inhibitor QAP1. Compounds 18 and 19b showed inhibition of Topo-II in in vitro assays and exhibited moderate, Topo-II level dependent cytotoxicity in SK-BR-3 and MCF-7 cell lines. Based on these results, 18F-labeled analogs of these two compounds were synthesized and evaluated as PET probes for imaging Topo-II overexpression in mice bearing SK-BR-3 xenografts. [18F]-18 and [18F]-19b were synthesized from their corresponding protected tosylated derivatives by fluorination and subsequent deprotection. Small animal PET imaging studies indicated that both compounds do not accumulate in tumors and exhibit poor pharmacokinetics, clearing from the blood pool very rapidly and getting metabolized over. The insights gained from the current study will surely aid in the design and construction of future generations of PET agents for the non-invasive delineation of Topo-II expression. PMID:25240701
Development of an MRI-compatible digital SiPM detector stack for simultaneous PET/MRI.
Düppenbecker, Peter M; Weissler, Bjoern; Gebhardt, Pierre; Schug, David; Wehner, Jakob; Marsden, Paul K; Schulz, Volkmar
2016-02-01
Advances in solid-state photon detectors paved the way to combine positron emission tomography (PET) and magnetic resonance imaging (MRI) into highly integrated, truly simultaneous, hybrid imaging systems. Based on the most recent digital SiPM technology, we developed an MRI-compatible PET detector stack, intended as a building block for next generation simultaneous PET/MRI systems. Our detector stack comprises an array of 8 × 8 digital SiPM channels with 4 mm pitch using Philips Digital Photon Counting DPC 3200-22 devices, an FPGA for data acquisition, a supply voltage control system and a cooling infrastructure. This is the first detector design that allows the operation of digital SiPMs simultaneously inside an MRI system. We tested and optimized the MRI-compatibility of our detector stack on a laboratory test bench as well as in combination with a Philips Achieva 3 T MRI system. Our design clearly reduces distortions of the static magnetic field compared to a conventional design. The MRI static magnetic field causes weak and directional drift effects on voltage regulators, but has no direct impact on detector performance. MRI gradient switching initially degraded energy and timing resolution. Both distortions could be ascribed to voltage variations induced on the bias and the FPGA core voltage supply respectively. Based on these findings, we improved our detector design and our final design shows virtually no energy or timing degradations, even during heavy and continuous MRI gradient switching. In particular, we found no evidence that the performance of the DPC 3200-22 digital SiPM itself is degraded by the MRI system.
Non-input analysis for incomplete trapping irreversible tracer with PET.
Ohya, Tomoyuki; Kikuchi, Tatsuya; Fukumura, Toshimitsu; Zhang, Ming-Rong; Irie, Toshiaki
2013-07-01
When using metabolic trapping type tracers, the tracers are not always trapped in the target tissue; i.e., some are completely trapped in the target, but others can be eliminated from the target tissue at a measurable rate. The tracers that can be eliminated are termed 'incomplete trapping irreversible tracers'. These incomplete trapping irreversible tracers may be clinically useful when the tracer β-value, the ratio of the tracer (metabolite) elimination rate to the tracer efflux rate, is under approximately 0.1. In this study, we propose a non-input analysis for incomplete trapping irreversible tracers based on the shape analysis (Shape), a non-input analysis used for irreversible tracers. A Monte Carlo simulation study based on experimental monkey data with two actual PET tracers (a complete trapping irreversible tracer [(11)C]MP4A and an incomplete trapping irreversible tracer [(18)F]FEP-4MA) was performed to examine the effects of the environmental error and the tracer elimination rate on the estimation of the k3-parameter (corresponds to metabolic rate) using Shape (original) and modified Shape (M-Shape) analysis. The simulation results were also compared with the experimental results obtained with the two PET tracers. When the tracer β-value was over 0.03, the M-Shape method was superior to the Shape method for the estimation of the k3-parameter. The simulation results were also in reasonable agreement with the experimental ones. M-Shape can be used as the non-input analysis of incomplete trapping irreversible tracers for PET study. Copyright © 2013 Elsevier Inc. All rights reserved.
Mild traumatic brain injury results in depressed cerebral glucose uptake: An (18)FDG PET study.
Selwyn, Reed; Hockenbury, Nicole; Jaiswal, Shalini; Mathur, Sanjeev; Armstrong, Regina C; Byrnes, Kimberly R
2013-12-01
Moderate to severe traumatic brain injury (TBI) in humans and rats induces measurable metabolic changes, including a sustained depression in cerebral glucose uptake. However, the effect of a mild TBI on brain glucose uptake is unclear, particularly in rodent models. This study aimed to determine the glucose uptake pattern in the brain after a mild lateral fluid percussion (LFP) TBI. Briefly, adult male rats were subjected to a mild LFP and positron emission tomography (PET) imaging with (18)F-fluorodeoxyglucose ((18)FDG), which was performed prior to injury and at 3 and 24 h and 5, 9, and 16 days post-injury. Locomotor function was assessed prior to injury and at 1, 3, 7, 14, and 21 days after injury using modified beam walk tasks to confirm injury severity. Histology was performed at either 10 or 21 days post-injury. Analysis of function revealed a transient impairment in locomotor ability, which corresponds to a mild TBI. Using reference region normalization, PET imaging revealed that mild LFP-induced TBI depresses glucose uptake in both the ipsilateral and contralateral hemispheres in comparison with sham-injured and naïve controls from 3 h to 5 days post-injury. Further, areas of depressed glucose uptake were associated with regions of glial activation and axonal damage, but no measurable change in neuronal loss or gross tissue damage was observed. In conclusion, we show that mild TBI, which is characterized by transient impairments in function, axonal damage, and glial activation, results in an observable depression in overall brain glucose uptake using (18)FDG-PET.
Modeling Commercial Freshwater Turtle Production on US Farms for Pet and Meat Markets
Mali, Ivana; Wang, Hsiao-Hsuan; Grant, William E.; Feldman, Mark; Forstner, Michael R. J.
2015-01-01
Freshwater turtles are being exploited for meat, eggs, traditional medicine, and pet trade. As a response, turtle farming became a booming aquaculture industry in the past two decades, specifically in the southeastern states of the United States of America (US) and across Southeast Asia. However, US turtle farms are currently producing turtles only for the pet trade while commercial trappers remain focused on catching the largest individuals from the wild. In our analyses we have created a biological and economic model that describes farming operations on a representative turtle farm in Louisiana. We first modeled current production of hatchling and yearling red-eared slider turtles (Trachemys scripta elegans) (i.e., traditional farming) for foreign and domestic pet markets, respectively. We tested the possibility of harvesting adult turtles from the breeding stock for sale to meat markets to enable alternative markets for the farmers, while decreasing the continued pressures on wild populations (i.e., non-traditional farming). Our economic model required current profit requirements of ~$13/turtle or ~$20.31/kg of meat from non-traditional farming in order to acquire the same profit as traditional farming, a value which currently exceeds market values of red-eared sliders. However, increasing competition with Asian turtle farms and decreasing hatchling prices may force the shift in the US toward producing turtles for meat markets. In addition, our model can be modified and applied to more desirable species on the meat market once more knowledge is acquired about species life histories and space requirements under farmed conditions. PMID:26407157
Human thermal comfort conditions and urban planning in hot-humid climates—The case of Cuba
NASA Astrophysics Data System (ADS)
Rodríguez Algeciras, José Abel; Coch, Helena; De la Paz Pérez, Guillermo; Chaos Yeras, Mabel; Matzarakis, Andreas
2016-08-01
Climate regional characteristics, urban environmental conditions, and outdoors thermal comfort requirements of residents are important for urban planning. Basic studies of urban microclimate can provide information and useful resources to predict and improve thermal conditions in hot-humid climatic regions. The paper analyzes the thermal bioclimate and its influence as urban design factor in Cuba, using Physiologically Equivalent Temperature (PET). Simulations of wind speed variations and shade conditions were performed to quantify changes in thermal bioclimate due to possible modifications in urban morphology. Climate data from Havana, Camagüey, and Santiago of Cuba for the period 2001 to 2012 were used to calculate PET with the RayMan model. The results show that changes in meteorological parameters influence the urban microclimate, and consequently modify the thermal conditions in outdoors spaces. Shade is the predominant strategy to improve urban microclimate with more significant benefits in terms of PET higher than 30 °C. For climatic regions such as the analyzed ones, human thermal comfort can be improved by a wind speed modification for thresholds of PET above 30 °C, and by a wind speed decreases in conditions below 26 °C. The improvement of human thermal conditions is crucial for urban sustainability. On this regards, our study is a contribution for urban designers, due to the possibility of taking advantage of results for improving microclimatic conditions based on urban forms. The results may enable urban planners to create spaces that people prefer to visit, and also are usable in the reconfiguration of cities.
Modeling Commercial Freshwater Turtle Production on US Farms for Pet and Meat Markets.
Mali, Ivana; Wang, Hsiao-Hsuan; Grant, William E; Feldman, Mark; Forstner, Michael R J
2015-01-01
Freshwater turtles are being exploited for meat, eggs, traditional medicine, and pet trade. As a response, turtle farming became a booming aquaculture industry in the past two decades, specifically in the southeastern states of the United States of America (US) and across Southeast Asia. However, US turtle farms are currently producing turtles only for the pet trade while commercial trappers remain focused on catching the largest individuals from the wild. In our analyses we have created a biological and economic model that describes farming operations on a representative turtle farm in Louisiana. We first modeled current production of hatchling and yearling red-eared slider turtles (Trachemys scripta elegans) (i.e., traditional farming) for foreign and domestic pet markets, respectively. We tested the possibility of harvesting adult turtles from the breeding stock for sale to meat markets to enable alternative markets for the farmers, while decreasing the continued pressures on wild populations (i.e., non-traditional farming). Our economic model required current profit requirements of ~$13/turtle or ~$20.31/kg of meat from non-traditional farming in order to acquire the same profit as traditional farming, a value which currently exceeds market values of red-eared sliders. However, increasing competition with Asian turtle farms and decreasing hatchling prices may force the shift in the US toward producing turtles for meat markets. In addition, our model can be modified and applied to more desirable species on the meat market once more knowledge is acquired about species life histories and space requirements under farmed conditions.
Human thermal comfort conditions and urban planning in hot-humid climates-The case of Cuba.
Rodríguez Algeciras, José Abel; Coch, Helena; De la Paz Pérez, Guillermo; Chaos Yeras, Mabel; Matzarakis, Andreas
2016-08-01
Climate regional characteristics, urban environmental conditions, and outdoors thermal comfort requirements of residents are important for urban planning. Basic studies of urban microclimate can provide information and useful resources to predict and improve thermal conditions in hot-humid climatic regions. The paper analyzes the thermal bioclimate and its influence as urban design factor in Cuba, using Physiologically Equivalent Temperature (PET). Simulations of wind speed variations and shade conditions were performed to quantify changes in thermal bioclimate due to possible modifications in urban morphology. Climate data from Havana, Camagüey, and Santiago of Cuba for the period 2001 to 2012 were used to calculate PET with the RayMan model. The results show that changes in meteorological parameters influence the urban microclimate, and consequently modify the thermal conditions in outdoors spaces. Shade is the predominant strategy to improve urban microclimate with more significant benefits in terms of PET higher than 30 °C. For climatic regions such as the analyzed ones, human thermal comfort can be improved by a wind speed modification for thresholds of PET above 30 °C, and by a wind speed decreases in conditions below 26 °C. The improvement of human thermal conditions is crucial for urban sustainability. On this regards, our study is a contribution for urban designers, due to the possibility of taking advantage of results for improving microclimatic conditions based on urban forms. The results may enable urban planners to create spaces that people prefer to visit, and also are usable in the reconfiguration of cities.
Distribution of monoamine oxidase proteins in human brain: implications for brain imaging studies
Tong, Junchao; Meyer, Jeffrey H; Furukawa, Yoshiaki; Boileau, Isabelle; Chang, Li-Jan; Wilson, Alan A; Houle, Sylvain; Kish, Stephen J
2013-01-01
Positron emission tomography (PET) imaging of monoamine oxidases (MAO-A: [11C]harmine, [11C]clorgyline, and [11C]befloxatone; MAO-B: [11C]deprenyl-D2) has been actively pursued given clinical importance of MAOs in human neuropsychiatric disorders. However, it is unknown how well PET outcome measures for the different radiotracers are quantitatively related to actual MAO protein levels. We measured regional distribution (n=38) and developmental/aging changes (21 hours to 99 years) of both MAOs by quantitative immunoblotting in autopsied normal human brain. MAO-A was more abundant than MAO-B in infants, which was reversed as MAO-B levels increased faster before 1 year and, unlike MAO-A, kept increasing steadily to senescence. In adults, regional protein levels of both MAOs were positively and proportionally correlated with literature postmortem data of MAO activities and binding densities. With the exception of [11C]befloxatone (binding potential (BP), r=0.61, P=0.15), correlations between regional PET outcome measures of binding in the literature and MAO protein levels were good (P<0.01) for [11C]harmine (distribution volume, r=0.86), [11C]clorgyline (λk3, r=0.82), and [11C]deprenyl-D2 (λk3 or modified Patlak slope, r=0.78 to 0.87), supporting validity of the latter imaging measures. However, compared with in vitro data, the latter PET measures underestimated regional contrast by ∼2-fold. Further studies are needed to address cause of the in vivo vs. in vitro nonproportionality. PMID:23403377
Matsumura, Kazushi; Zouda, Maki; Wada, Yasuhiro; Yamashita, Fumiyoshi; Hashida, Mitsuru; Watanabe, Yasuyoshi; Mukai, Hidefumi
2018-05-07
Radiolabeled antibodies, polyethylene glycol-conjugated (PEGylated) peptides, liposomes, and other materials were investigated as positron-emission tomography (PET) probes. These substances accumulate in tumors but often remain too long in circulation. We investigated the combination of intravenous urokinase injection and its substrate linker as a triggered radioisotope clearance enhancement system to improve imaging contrast. To this end, we synthesized a four-arm PEGylated 64 Cu-bombesin analog tetramer with a urokinase substrate linker. In mouse blood, it was almost perfectly cleaved and degraded into smaller radioactive fragments in vitro with urokinase (≥20,000 IU/mL). In mouse blood circulation, ∼50-65% of the probe was rapidly degraded after the urokinase injection and the radioactive fragments were eliminated mainly from the kidney. In contrast, tumor radioactivity levels did not change, and therefore, the tumors were clearly visualized. The tumor/blood ratio, an indicator of imaging contrast, increased 2.5 times, while elimination of the radioisotope from the blood was enhanced. This approach has the potential to improve imaging contrast using various PET probes. It could also shorten the time required to obtain sufficient contrast and decrease patient radiation exposure. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hooker, J.M.; Hooker, J.M.; Kim, S.W.
2009-10-01
MS-275 (entinostat) is a histone deacetylase (HDAC) inhibitor currently in clinical trials for the treatment of several types of cancer. Recent reports have noted that MS-275 can cross the blood-brain barrier (BBB) and cause region-specific changes in rodent brain histone acetylation. To characterize the pharmacokinetics and distribution of MS-275 in the brain using positron emission tomography (PET), we labeled the carbamate carbon of MS-275 with carbon-11. Using PET, we determined that [{sup 11}C]MS-275 has low uptake in brain tissue when administered intravenously to nonhuman primates. In rodent studies, we observed that pharmacokinetics and brain accumulation of [{sup 11}C]MS-275 were notmore » changed by the coadministration of large doses of unlabeled MS-275. These results, which both highlight the poor brain penetration of MS-275, clearly suggest its limitation as a therapeutic agent for the central nervous system (CNS). Moreover, our study demonstrates the effectiveness of PET at providing brain pharmacokinetic data for HDAC inhibitors. These data are important not only for the development of new compounds for peripheral cancer treatment (where CNS exclusion is often advantageous) but also for the treatment of neurological disorders (where CNS penetration is critical).« less
Venanzi, Mariano; Gatto, Emanuela; Caruso, Mario; Porchetta, Alessandro; Formaggio, Fernando; Toniolo, Claudio
2014-08-21
Photoinduced electron transfer (PET) experiments have been carried out on peptide self-assembled monolayers (SAM) chemisorbed on a gold substrate. The oligopeptide building block was exclusively formed by C(α)-tetrasubstituted α-aminoisobutyric residues to attain a helical conformation despite the shortness of the peptide chain. Furthermore, it was functionalized at the C-terminus by a pyrene choromophore to enhance the UV photon capture cross-section of the compound and by a lipoic group at the N-terminus for linking to gold substrates. Electron transfer across the peptide SAM has been studied by photocurrent generation experiments in an electrochemical cell employing a gold substrate modified by chemisorption of a peptide SAM as a working electrode and by steady-state and time-resolved fluorescence experiments in solution and on a gold-coated glass. The results show that the electronic flow through the peptide bridge is strongly asymmetric; i.e., PET from the C-terminus to gold is highly favored with respect to PET in the opposite direction. This effect arises from the polarity of the Au-S linkage (Au(δ+)-S(δ-), junction effect) and from the electrostatic field generated by the peptide helix.
A Pretargeted Approach for the Multimodal PET/NIRF Imaging of Colorectal Cancer.
Adumeau, Pierre; Carnazza, Kathryn E; Brand, Christian; Carlin, Sean D; Reiner, Thomas; Agnew, Brian J; Lewis, Jason S; Zeglis, Brian M
2016-01-01
The complementary nature of positron emission tomography (PET) and near-infrared fluorescence (NIRF) imaging makes the development of strategies for the multimodal PET/NIRF imaging of cancer a very enticing prospect. Indeed, in the context of colorectal cancer, a single multimodal PET/NIRF imaging agent could be used to stage the disease, identify candidates for surgical intervention, and facilitate the image-guided resection of the disease. While antibodies have proven to be highly effective vectors for the delivery of radioisotopes and fluorophores to malignant tissues, the use of radioimmunoconjugates labeled with long-lived nuclides such as 89 Zr poses two important clinical complications: high radiation doses to the patient and the need for significant lag time between imaging and surgery. In vivo pretargeting strategies that decouple the targeting vector from the radioactivity at the time of injection have the potential to circumvent these issues by facilitating the use of positron-emitting radioisotopes with far shorter half-lives. Here, we report the synthesis, characterization, and in vivo validation of a pretargeted strategy for the multimodal PET and NIRF imaging of colorectal carcinoma. This approach is based on the rapid and bioorthogonal ligation between a trans -cyclooctene- and fluorophore-bearing immunoconjugate of the huA33 antibody (huA33-Dye800-TCO) and a 64 Cu-labeled tetrazine radioligand ( 64 Cu-Tz-SarAr). In vivo imaging experiments in mice bearing A33 antigen-expressing SW1222 colorectal cancer xenografts clearly demonstrate that this approach enables the non-invasive visualization of tumors and the image-guided resection of malignant tissue, all at only a fraction of the radiation dose created by a directly labeled radioimmunoconjugate. Additional in vivo experiments in peritoneal and patient-derived xenograft models of colorectal carcinoma reinforce the efficacy of this methodology and underscore its potential as an innovative and useful clinical tool.
Wang, Qiang; Wen, Jie; Ravindranath, Bosky; O'Sullivan, Andrew W; Catherall, David; Li, Ke; Wei, Shouyi; Komarov, Sergey; Tai, Yuan-Chuan
2015-09-11
Compact high-resolution panel detectors using virtual pinhole (VP) PET geometry can be inserted into existing clinical or pre-clinical PET systems to improve regional spatial resolution and sensitivity. Here we describe a compact panel PET detector built using the new Though Silicon Via (TSV) multi-pixel photon counters (MPPC) detector. This insert provides high spatial resolution and good timing performance for multiple bio-medical applications. Because the TSV MPPC design eliminates wire bonding and has a package dimension which is very close to the MPPC's active area, it is 4-side buttable. The custom designed MPPC array (based on Hamamatsu S12641-PA-50(x)) used in the prototype is composed of 4 × 4 TSV-MPPC cells with a 4.46 mm pitch in both directions. The detector module has 16 × 16 lutetium yttrium oxyorthosilicate (LYSO) crystal array, with each crystal measuring 0.92 × 0.92 × 3 mm 3 with 1.0 mm pitch. The outer diameter of the detector block is 16.8 × 16.8 mm 2 . Thirty-two such blocks will be arranged in a 4 × 8 array with 1 mm gaps to form a panel detector with detection area around 7 cm × 14 cm in the full-size detector. The flood histogram acquired with Ge-68 source showed excellent crystal separation capability with all 256 crystals clearly resolved. The detector module's mean, standard deviation, minimum (best) and maximum (worst) energy resolution were 10.19%, +/-0.68%, 8.36% and 13.45% FWHM, respectively. The measured coincidence time resolution between the block detector and a fast reference detector (around 200 ps single photon timing resolution) was 0.95 ns. When tested with Siemens Cardinal electronics the performance of the detector blocks remain consistent. These results demonstrate that the TSV-MPPC is a promising photon sensor for use in a flat panel PET insert composed of many high resolution compact detector modules.
Eustache, F; Desgranges, B; Petit-Taboué, M C; de la Sayette, V; Piot, V; Sablé, C; Marchal, G; Baron, J C
1997-09-01
To assess explicit memory and two components of implicit memory--that is, perceptual-verbal skill learning and lexical-semantic priming effects--as well as resting cerebral blood flow (CBF) and oxygen metabolism (CMRO2) during the acute phase of transient global amnesia. In a 59 year old woman, whose amnestic episode fulfilled all current criteria for transient global amnesia, a neuropsychological protocol was administered, including word learning, story recall, categorical fluency, mirror reading, and word stem completion tasks. PET was performed using the (15)O steady state inhalation method, while the patient still exhibited severe anterograde amnesia and was interleaved with the cognitive tests. There was a clear cut dissociation between impaired long term episodic memory and preserved implicit memory for its two components. Categorical fluency was significantly altered, suggesting word retrieval strategy--rather than semantic memory--impairment. The PET study disclosed a reduced CMRO2 with relatively or fully preserved CBF in the left prefrontotemporal cortex and lentiform nucleus, and the reverse pattern over the left occipital cortex. The PET alterations with patchy CBF-CMRO2 uncoupling would be compatible with a migraine-like phenomenon and indicate that the isolated assessment of perfusion in transient global amnesia may be misleading. The pattern of metabolic depression, with sparing of the hippocampal area, is one among the distinct patterns of brain dysfunction that underlie the (apparently) uniform clinical presentation of transient global amnesia. The finding of a left prefrontal hypometabolism in the face of impaired episodic memory and altered verbal fluency would fit present day concepts from PET activation studies about the role of this area in episodic and semantic memory encoding/retrieval. Likewise, the changes affecting the lenticular nucleus but sparing the caudate would be consistent with the normal performance in perceptual-verbal skill learning. Finally, unaltered lexical-semantic priming effects, despite left temporal cortex hypometabolism, suggest that these processes are subserved by a more distributed neocortical network.
NASA Astrophysics Data System (ADS)
Kersemans, Ken; Bauwens, Matthias; Lahoutte, Tony; Bossuyt, Axel; Mertens, John
2007-02-01
The Na +-independent L-type LAT1 amino acid transport system for large and neutral amino acids has been shown to be expressed higher in tumour tissue relative to normal tissue and has been regarded as a key point for the development of new amino acid based tumour tracers for molecular imaging. We developed a new fluorinated phenylalanine analogue, 2-[ 18F]fluoromethyl- L-phenylalanine, considering that the spatial volume of FCH 3 is comparable with that of the iodine atom in 2-I- L-phenylalanine, of which we have proven that it is taken up excellently in tumours by the LAT1 system. The substrate molecule for radiolabeling, Boc-2-bromomethyl- L-phenylalanine- tButylester, was prepared by radical bromination of Boc-2-methyl- L-phenylalanine- tButylester. [ 18F -] for bromine exchange is performed within 3 min in conditions comparable to the [ 18F]FDG synthesis with a radiochemical yield of at least 85%. After deprotection and semi-preparative HPLC purification, the 2-[ 18F]fluoromethyl- L-phenylalanine is recovered n.c.a. (57%) with a high purity and 3.7 MBq were injected into R1M rhabdomyosarcoma tumour-bearing rats. Imaging was performed with a human PET camera from 5 to 45 min p.i. The tumour/background and tumour/blood ratios obtained from PET acquisition were at least 2.5. DUR values for the tumours were at least about 5. Furthermore, a small tumour implanted near a kidney could be well visualized completely separated from this kidney. Moreover in all tumours the "active" tumour tissue can clearly be differentiated from less active tumour tissue. This proves that 2-[ 18F]fluoromethyl- L-phenylalanine has a great potential as a new tracer for specific tumour diagnosis with PET.
Sinusas, Albert J; Lazewatsky, Joel; Brunetti, Jacqueline; Heller, Gary; Srivastava, Ajay; Liu, Yi-Hwa; Sparks, Richard; Puretskiy, Andrey; Lin, Shu-fei; Crane, Paul; Carson, Richard E; Lee, L Veronica
2014-09-01
A novel (18)F-labeled ligand for the norepinephrine transporter (N-[3-bromo-4-(3-(18)F-fluoro-propoxy)-benzyl]-guanidine [LMI1195]) is in clinical development for mapping cardiac nerve terminals in vivo using PET. Human safety, whole-organ biodistribution, and radiation dosimetry of LMI1195 were evaluated in a phase 1 clinical trial. Twelve healthy subjects at 3 clinical sites were injected intravenously with 150-250 MBq of LMI1195. Dynamic PET images were obtained over the heart for 10 min, followed by sequential whole-body images for approximately 5 h. Blood samples were obtained, and heart rate, electrocardiogram, and blood pressure were monitored before and during imaging. Residence times were determined from multiexponential regression of organ region-of-interest data normalized by administered activity (AA). Radiation dose estimates were calculated using OLINDA/EXM. Myocardial, lung, liver, and blood-pool standardized uptake values were determined at different time intervals. No adverse events due to LMI1195 were seen. Blood radioactivity cleared quickly, whereas myocardial uptake remained stable and uniform throughout the heart over 4 h. Liver and lung activity cleared relatively rapidly, providing favorable target-to-background ratios for cardiac imaging. The urinary bladder demonstrated the largest peak uptake (18.3% AA), followed by the liver (15.5% AA). The mean effective dose was 0.026 ± 0.0012 mSv/MBq. Approximately 1.6% AA was seen in the myocardium initially, remaining above 1.5% AA (decay-corrected) through 4 h after injection. The myocardium-to-liver ratio was approximately unity initially, increasing to more than 2 at 4 h. These preliminary data suggest that LMI1195 is well tolerated and yields a radiation dose comparable to that of other commonly used PET radiopharmaceuticals. The kinetics of myocardial and adjacent organ activity suggest that cardiac imaging should be possible with acceptable patient radiation dose. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Foss, Catherine A; Plyku, Donika; Ordonez, Alvaro A; Sanchez-Bautista, Julian; Rosenthal, Hailey B; Minn, I L; Lodge, Martin A; Pomper, Martin G; Sgouros, George; Jain, Sanjay K
2018-04-26
Whole body PET/CT imaging was performed using 124 I-iodo-DPA-713, a radioligand for the 18-kDa translocator protein (TSPO), to determine biodistribution and radiation dosimetry. Healthy subjects ages 18-65 years underwent whole body PET/CT imaging at either 4, 24 and 48 hours or 24, 48 and 72 hours after intravenous injection with 124 I-iodo-DPA-713. Time-activity curves were generated and used to calculate organ time-integrated activity coefficients for each subject. The resulting time-integrated activity coefficients provided input data for calculation of organ absorbed doses and effective dose for each subject using OLINDA. Subjects were genotyped for the TSPO polymorphism, rs6971, and plasma protein binding of 124 I-iodo-DPA-713 was measured. Three male and three female adults with mean age of 40 ± 19 years were imaged. The mean administered activity and mass were 70.5 ± 5.1 (range, 62.4-78.1) MBq and 469 ± 34 (range, 416-520) ng respectively. There were no adverse or clinically detectable pharmacologic effects in any of the six subjects. No changes in vital signs, laboratory values or electrocardiograms were observed. 124 I-Iodo-DPA-713 cleared rapidly (4 hours post-injection) from the lungs with hepatic elimination and localization to the gastrointestinal tract. The mean effective dose over six subjects was 0.459 ± 0.127 mSv/MBq with the liver being the dose-limiting organ (0.924 ± 0.501 mGy/MBq). The percentage of free radiotracer in blood was ~30% at 30 and 60 minutes post-injection. Iodo-DPA-713 is cleared rapidly from the lungs with predominant hepatic elimination. It is safe and well-tolerated in healthy adult subjects. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Modifying the Balanced Scorecard for a Network Industry The Case of the Clearing Industry
NASA Astrophysics Data System (ADS)
Chlistalla, Michael; Schaper, Torsten
The Balanced Scorecard (BSC) is a well-established framework for the management of a company as it integrates financial and non-financial perspectives. Little attention has been given to its theoretical and conceptual valuation. We illustrate how the stakeholder value theory corresponds with the concept of the BSC and show the importance of underlying cause-and-effect relationships between its perspectives. For the case of clearing in Europe which is currently facing profound changes, we present our three-phased approach how to adjust and to extend Kaplan and Norton’s original concept. We modify the generic BSC by adding risk management as a separate perspective and by integrating competition and IT. Based on multiple case studies, we then validate whether the modified BSC is suited to meet the specifics of the clearing industry.
Ettrup, Anders; Hansen, Martin; Santini, Martin A; Paine, James; Gillings, Nic; Palner, Mikael; Lehel, Szabolcs; Herth, Matthias M; Madsen, Jacob; Kristensen, Jesper; Begtrup, Mikael; Knudsen, Gitte M
2011-04-01
Positron emission tomography (PET) imaging of serotonin 2A (5-HT(2A)) receptors with agonist tracers holds promise for the selective labelling of 5-HT(2A) receptors in their high-affinity state. We have previously validated [(11)C]Cimbi-5 and found that it is a 5-HT(2A) receptor agonist PET tracer. In an attempt to further optimize the target-to-background binding ratio, we modified the chemical structure of the phenethylamine backbone and carbon-11 labelling site of [(11)C]Cimbi-5 in different ways. Here, we present the in vivo validation of nine novel 5-HT(2A) receptor agonist PET tracers in the pig brain. Each radiotracer was injected intravenously into anaesthetized Danish Landrace pigs, and the pigs were subsequently scanned for 90 min in a high-resolution research tomography scanner. To evaluate 5-HT(2A) receptor binding, cortical nondisplaceable binding potentials (BP(ND)) were calculated using the simplified reference tissue model with the cerebellum as a reference region. After intravenous injection, all compounds entered the brain and distributed preferentially into the cortical areas, in accordance with the known 5-HT(2A) receptor distribution. The largest target-to-background binding ratio was found for [(11)C]Cimbi-36 which also had a high brain uptake compared to its analogues. The cortical binding of [(11)C]Cimbi-36 was decreased by pretreatment with ketanserin, supporting 5-HT(2A) receptor selectivity in vivo. [(11)C]Cimbi-82 and [(11)C]Cimbi-21 showed lower cortical BP(ND), while [(11)C]Cimbi-27, [(11)C]Cimbi-29, [(11)C]Cimbi-31 and [(11)C]Cimbi-88 gave rise to cortical BP(ND) similar to that of [(11)C]Cimbi-5. [(11)C]Cimbi-36 is currently the most promising candidate for investigation of 5-HT(2A) receptor agonist binding in the living human brain with PET.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... Proposed Rule Change, as Previously Modified by Amendment Nos. 1 and 2, To Institute Supplemental Liquidity Deposits to Its Clearing Fund Designed To Increase Liquidity Resources To Meet Its Liquidity Needs October...'') to provide for supplemental liquidity deposits to its Clearing Fund (the ``NSCC Clearing Fund'') to...
Characterization of an atmospheric pressure air plasma source for polymer surface modification
NASA Astrophysics Data System (ADS)
Yang, Shujun; Tang, Jiansheng
2013-10-01
An atmospheric pressure air plasma source was generated through dielectric barrier discharge (DBD). It was used to modify polyethyleneterephthalate (PET) surfaces with very high throughput. An equivalent circuit model was used to calculate the peak average electron density. The emission spectrum from the plasma was taken and the main peaks in the spectrum were identified. The ozone density in the down plasma region was estimated by Absorption Spectroscopy. NSF and ARC-ODU
Brush, J; Boyd, K; Chappell, F; Crawford, F; Dozier, M; Fenwick, E; Glanville, J; McIntosh, H; Renehan, A; Weller, D; Dunlop, M
2011-09-01
In the UK, colorectal cancer (CRC) is the third most common malignancy (behind lung and breast cancer) with 37,514 cases registered in 2006: around two-thirds (23,384) in the colon and one-third (14,130) in the rectum. Treatment of cancers of the colon can vary considerably, but surgical resection is the mainstay of treatment for curative intent. Following surgical resection, there is a comprehensive assessment of the tumour, it's invasion characteristics and spread (tumour staging). A number of imaging modalities are used in the pre-operative staging of CRCs including; computerised tomography (CT), magnetic resonance imaging, ultrasound imaging and positron emission tomography (PET). This report examines the role of CT in combination with PET scanning (PET/CT 'hybrid' scan). The research objectives are: to evaluate the diagnostic accuracy and therapeutic impact of fluorine-18-deoxyglucose (FDG) PET/CT for the pre-operative staging of primary, recurrent and metastatic cancer using systematic review methods; undertake probabilistic decision-analytic modelling (using Monte Carlo simulation); and conduct a value of information analysis to help inform whether or not there is potential worth in undertaking further research. For each aspect of the research - the systematic review, the handsearch study and the economic evaluation - a database was assembled from a comprehensive search for published and unpublished studies, which included database searches, reference lists search and contact with experts. In the systematic review prospective and retrospective patient series (diagnostic cohort) and randomised controlled trials (RCTs) were eligible for inclusion. Both consecutive series and series that are not explicitly reported as consecutive were included. Two reviewers extracted all data and applied the criteria independently and resolved disagreements by discussion. Data to populate 2 × 2 contingency tables consisting of the number of true positives, true negatives, false positives and false negatives using the studies' own definitions were extracted, as were data relating to changes in management. Fourteen items from the Quality Assessment of Diagnostic Accuracy Studies checklist were used to assess the methodological quality of the included studies. Patient-level data were used to calculate sensitivity and specificity with confidence intervals (CIs). Data were plotted graphically in forest plots. For the economic evaluation, economic models were designed for each of the disease states: primary, recurrent and metastatic. These were developed and populated based on a variety of information sources (in particular from published data sources) and literature, and in consultation with clinical experts. The review found 30 studies that met the eligibility criteria. Only two small studies evaluated the use of FDG PET/CT in primary CRC, and there is insufficient evidence to support its routine use at this time. The use of FDG PET/CT for the detection of recurrent disease identified data from five retrospective studies from which a pooled sensitivity of 91% (95% CI 0.87% to 0.95%) and specificity of 91% (95% CI 0.85% to 0.95%) were observed. Pooled accuracy data from patients undergoing staging for suspected metastatic disease showed FDG PET/CT to have a pooled sensitivity of 91% (95% CI 87% to 94%) and a specificity of 76% (95% CI 58% to 88%), but the poor quality of the studies means the validity of the data may be compromised by several biases. The separate handsearch study did not yield any additional unique studies relevant to FDG PET/CT. Models for recurrent disease demonstrated an incremental cost-effectiveness ratio of £ 21,409 per quality-adjusted life-year (QALY) for rectal cancer, £ 6189 per QALY for colon cancer and £ 21,434 per QALY for metastatic disease. The value of handsearching to identify studies of less clearly defined or reported diagnostic tests is still to be investigated. The systematic review found insufficient evidence to support the routine use of FDG PET/CT in primary CRC and only a small amount of evidence supporting its use in the pre-operative staging of recurrent and metastatic CRC, and, although FDG PET/CT was shown to change patient management, the data are divergent and the quality of research is generally poor. The handsearch to identify studies of less clearly defined or reported diagnostic tests did not find additional studies. The primary limitations in the economic evaluations were due to uncertainty and lack of available evidence from the systematic reviews for key parameters in each of the five models. In order to address this, a conservative approach was adopted in choosing DTA estimates for the model parameters. Probabilistic analyses were undertaken for each of the models, incorporating wide levels of uncertainty particularly for the DTA estimates. None of the economic models reported cost-savings, but the approach adopted was conservative in order to determine more reliable results given the lack of current information. The economic evaluations conclude that FDG PET/CT as an add-on imaging device is cost-effective in the pre-operative staging of recurrent colon, recurrent rectal and metastatic disease but not in primary colon or rectal cancers. There would be value in undertaking an RCT with a concurrent economic evaluation to evaluate the therapeutic impact and cost-effectiveness of FDG PET/CT compared with conventional imaging (without PET) for the pre-operative staging of recurrent and metastatic CRC.
PT2385 for the Treatment of Von Hippel-Lindau Disease-Associated Clear Cell Renal Cell Carcinoma
2017-08-23
VHL Gene Mutation; VHL; VHL Syndrome; VHL Gene Inactivation; Von Hippel; Von Hippel-Lindau Disease; Von Hippel's Disease; Von Hippel-Lindau Syndrome, Modifiers of; Clear Cell Renal Cell Carcinoma; Clear Cell RCC; ccRCC
Breeding bird responses to three silvicultural treatments in the Oregon Coast Range
Chambers, C.L.; McComb, W.C.; Tappeiner, J. C.
1999-01-01
Silvicultural alternatives to clear-cutting have been suggested to promote development, retention, or creation of late-successional features such as large trees, multilayered canopies, snags, and logs. We assessed bird response to three silvicultural alternatives to clear-cutting that retained structural features found in old Douglas-fir (Pseudotsuga menziesii) forests and that imitated natural disturbance regimes more closely than did traditional clear-cutting: (1) small-patch group selection treatment representing a low-intensity disturbance; (2) two-story treatment, representing a moderate to high-intensity disturbance; and (3) modified clear-cut treatment, representing a high-intensity disturbance. We counted diurnal breeding birds 1 yr prior to and 2 yr after harvest to estimate effects of the silvicultural treatments on bird communities compared with uncut controls. The small-patch group selection treatment was most similar in species composition to control stands. The two-story treatment was more similar to the modified clear-cut treatment. Ten bird species remained abundant following the small-patch group selection treatment. They declined in abundance in modified clearcuts and two-story stands. These species included four neotropical migratory species and five species with restricted geographic ranges and habitat associations. Nine species increased in response to moderate and/or high-intensity disturbances. This group included a larger proportion of species that were habitat generalists. Silvicultural treatments imitating low-intensity disturbances were most effective in retaining bird communities associated with mature forest; high-intensity disturbances such as the two-story and modified clear-cut treatments greatly altered bird community composition. Bird responses to the silvicultural treatments that we studied indicate that a variety of stand types is needed to meet needs of all species.
NASA Astrophysics Data System (ADS)
Böning, Guido; Todica, Andrei; Vai, Alessandro; Lehner, Sebastian; Xiong, Guoming; Mille, Erik; Ilhan, Harun; la Fougère, Christian; Bartenstein, Peter; Hacker, Marcus
2013-11-01
The assessment of left ventricular function, wall motion and myocardial viability using electrocardiogram (ECG)-gated [18F]-FDG positron emission tomography (PET) is widely accepted in human and in preclinical small animal studies. The nonterminal and noninvasive approach permits repeated in vivo evaluations of the same animal, facilitating the assessment of temporal changes in disease or therapy response. Although well established, gated small animal PET studies can contain erroneous gating information, which may yield to blurred images and false estimation of functional parameters. In this work, we present quantitative and visual quality control (QC) methods to evaluate the accuracy of trigger events in PET list-mode and physiological data. Left ventricular functional analysis is performed to quantify the effect of gating errors on the end-systolic and end-diastolic volumes, and on the ejection fraction (EF). We aim to recover the cardiac functional parameters by the application of the commonly established heart rate filter approach using fixed ranges based on a standardized population. In addition, we propose a fully reprocessing approach which retrospectively replaces the gating information of the PET list-mode file with appropriate list-mode decoding and encoding software. The signal of a simultaneously acquired ECG is processed using standard MATLAB vector functions, which can be individually adapted to reliably detect the R-peaks. Finally, the new trigger events are inserted into the PET list-mode file. A population of 30 mice with various health statuses was analyzed and standard cardiac parameters such as mean heart rate (119 ms ± 11.8 ms) and mean heart rate variability (1.7 ms ± 3.4 ms) derived. These standard parameter ranges were taken into account in the QC methods to select a group of nine optimal gated and a group of eight sub-optimal gated [18F]-FDG PET scans of mice from our archive. From the list-mode files of the optimal gated group, we randomly deleted various fractions (5% to 60%) of contained trigger events to generate a corrupted group. The filter approach was capable to correct the corrupted group and yield functional parameters with no significant difference to the optimal gated group. We successfully demonstrated the potential of the fully reprocessing approach by applying it to the sub-optimal group, where the functional parameters were significantly improved after reprocessing (mean EF from 41% ± 16% to 60% ± 13%). When applied to the optimal gated group the fully reprocessing approach did not alter the functional parameters significantly (mean EF from 64% ± 8% to 64 ± 7%). This work presents methods to determine and quantify erroneous gating in small animal gated [18F]-FDG PET scans. We demonstrate the importance of a quality check for cardiac triggering contained in PET list-mode data and the benefit of optionally reprocessing the fully recorded physiological information to retrospectively modify or fully replace the cardiac triggering in PET list-mode data. We aim to provide a preliminary guideline of how to proceed in the presence of errors and demonstrate that offline reprocessing by filtering erroneous trigger events and retrospective gating by ECG processing is feasible. Future work will focus on the extension by additional QC methods, which may exploit the amplitude of trigger events and ECG signal by means of pattern recognition. Furthermore, we aim to transfer the proposed QC methods and the fully reprocessing approach to human myocardial PET/CT.
Recovery and normalization of triple coincidences in PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lage, Eduardo, E-mail: elage@mit.edu; Parot, Vicente; Dave, Shivang R.
2015-03-15
Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose amore » simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with the authors’ method increased peak NEC rates of the scanner by 26.6% and 32% for mouse- and rat-sized objects, respectively. This increase in NEC-rate performance was also reflected in the image-quality metrics. Images reconstructed using double and triple coincidences recovered using their method had better signal-to-noise ratio than those obtained using only double coincidences, while preserving spatial resolution and contrast. Distribution of triple coincidences using an equal-weighting scheme increased apparent system sensitivity but degraded image quality. The performance boost provided by the inclusion of triple coincidences using their method allowed to reduce the acquisition time of standard imaging procedures by up to ∼25%. Conclusions: Recovering triple coincidences with the proposed method can effectively increase the sensitivity of current clinical and preclinical PET systems without compromising other parameters like spatial resolution or contrast.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-09
... Organizations; ICE Clear Credit LLC; Order Approving Proposed Rule Change To Reduce the Current Level of Risk Mutualization Among Clearing Participants and To Modify the Initial Margin Risk Model So That It Is Easier for... modifications to its risk model for clearing credit default swaps (``CDS'') contracts. For the first...
A modified method of 3D-SSP analysis for amyloid PET imaging using [¹¹C]BF-227.
Kaneta, Tomohiro; Okamura, Nobuyuki; Minoshima, Satoshi; Furukawa, Katsutoshi; Tashiro, Manabu; Furumoto, Shozo; Iwata, Ren; Fukuda, Hiroshi; Takahashi, Shoki; Yanai, Kazuhiko; Kudo, Yukitsuka; Arai, Hiroyuki
2011-12-01
Three-dimensional stereotactic surface projection (3D-SSP) analyses have been widely used in dementia imaging studies. However, 3D-SSP sometimes shows paradoxical results on amyloid positron emission tomography (PET) analyses. This is thought to be caused by errors in anatomical standardization (AS) based on an (18)F-fluorodeoxyglucose (FDG) template. We developed a new method of 3D-SSP analysis for amyloid PET imaging, and used it to analyze (11)C-labeled 2-(2-[2-dimethylaminothiazol-5-yl]ethenyl)-6-(2-[fluoro]ethoxy)benzoxazole (BF-227) PET images of subjects with mild cognitive impairment (MCI) and Alzheimer's disease (AD). The subjects were 20 with MCI, 19 patients with AD, and 17 healthy controls. Twelve subjects with MCI were followed up for 3 years or more, and conversion to AD was seen in 6 cases. All subjects underwent PET with both FDG and BF-227. For AS and 3D-SSP analyses of PET data, Neurostat (University of Washington, WA, USA) was used. Method 1 involves AS for BF-227 images using an FDG template. In this study, we developed a new method (Method 2) for AS: First, an FDG image was subjected to AS using an FDG template. Then, the BF-227 image of the same patient was registered to the FDG image, and AS was performed using the transformation parameters calculated for AS of the corresponding FDG images. Regional values were normalized by the average value obtained at the cerebellum and values were calculated for the frontal, parietal, temporal, and occipital lobes. For statistical comparison of the 3 groups, we applied one-way analysis of variance followed by the Bonferroni post hoc test. For statistical comparison between converters and non-converters, the t test was applied. Statistical significance was defined as p < 0.05. Among the 56 cases we studied, Method 1 demonstrated slight distortions after AS of the image in 16 cases and heavy distortions in 4 cases in which the distortions were not observed with Method 2. Both methods demonstrated that the values in AD and MCI patients were significantly higher than those in the controls, in the parietal, temporal, and occipital lobes. However, only Method 2 showed significant differences in the frontal lobes. In addition, Method 2 could demonstrate a significantly higher value in MCI-to-AD converters in the parietal and frontal lobes. Method 2 corrects AS errors that often occur when using Method 1, and has made appropriate 3D-SSP analysis of amyloid PET imaging possible. This new method of 3D-SSP analysis for BF-227 PET could prove useful for detecting differences between normal groups and AD and MCI groups, and between converters and non-converters.
2016-11-14
Cervical Adenocarcinoma; Cervical Adenosquamous Cell Carcinoma; Cervical Small Cell Carcinoma; Cervical Squamous Cell Carcinoma; Endometrial Clear Cell Carcinoma; Endometrial Papillary Serous Carcinoma; Stage I Endometrial Carcinoma; Stage IB Cervical Cancer; Stage II Endometrial Carcinoma; Stage IIA Cervical Cancer; Stage IIB Cervical Cancer; Stage III Cervical Cancer; Stage III Endometrial Carcinoma; Stage IVA Cervical Cancer
Holzgreve, Adrien; Brendel, Matthias; Gu, Song; Carlsen, Janette; Mille, Erik; Böning, Guido; Mastrella, Giorgia; Unterrainer, Marcus; Gildehaus, Franz J; Rominger, Axel; Bartenstein, Peter; Kälin, Roland E; Glass, Rainer; Albert, Nathalie L
2016-01-01
Noninvasive tumor growth monitoring is of particular interest for the evaluation of experimental glioma therapies. This study investigates the potential of positron emission tomography (PET) using O-(2-(18)F-fluoroethyl)-L-tyrosine ([(18)F]-FET) to determine tumor growth in a murine glioblastoma (GBM) model-including estimation of the biological tumor volume (BTV), which has hitherto not been investigated in the pre-clinical context. Fifteen GBM-bearing mice (GL261) and six control mice (shams) were investigated during 5 weeks by PET followed by autoradiographic and histological assessments. [(18)F]-FET PET was quantitated by calculation of maximum and mean standardized uptake values within a universal volume-of-interest (VOI) corrected for healthy background (SUVmax/BG, SUVmean/BG). A partial volume effect correction (PVEC) was applied in comparison to ex vivo autoradiography. BTVs obtained by predefined thresholds for VOI definition (SUV/BG: ≥1.4; ≥1.6; ≥1.8; ≥2.0) were compared to the histologically assessed tumor volume (n = 8). Finally, individual "optimal" thresholds for BTV definition best reflecting the histology were determined. In GBM mice SUVmax/BG and SUVmean/BG clearly increased with time, however at high inter-animal variability. No relevant [(18)F]-FET uptake was observed in shams. PVEC recovered signal loss of SUVmean/BG assessment in relation to autoradiography. BTV as estimated by predefined thresholds strongly differed from the histology volume. Strikingly, the individual "optimal" thresholds for BTV assessment correlated highly with SUVmax/BG (ρ = 0.97, p < 0.001), allowing SUVmax/BG-based calculation of individual thresholds. The method was verified by a subsequent validation study (n = 15, ρ = 0.88, p < 0.01) leading to extensively higher agreement of BTV estimations when compared to histology in contrast to predefined thresholds. [(18)F]-FET PET with standard SUV measurements is feasible for glioma imaging in the GBM mouse model. PVEC is beneficial to improve accuracy of [(18)F]-FET PET SUV quantification. Although SUVmax/BG and SUVmean/BG increase during the disease course, these parameters do not correlate with the respective tumor size. For the first time, we propose a histology-verified method allowing appropriate individual BTV estimation for volumetric in vivo monitoring of tumor growth with [(18)F]-FET PET and show that standardized thresholds from routine clinical practice seem to be inappropriate for BTV estimation in the GBM mouse model.
Nielsen, Carsten H; Jeppesen, Troels E; Kristensen, Lotte K; Jensen, Mette M; El Ali, Henrik H; Madsen, Jacob; Wiinberg, Bo; Petersen, Lars C; Kjaer, Andreas
2016-07-01
Tissue factor (TF) is the main initiator of the extrinsic coagulation cascade. However, TF also plays an important role in cancer. TF expression has been reported in 53%-89% of all pancreatic adenocarcinomas, and the expression level of TF has in clinical studies correlated with advanced stage, increased microvessel density, metastasis, and poor overall survival. Imaging of TF expression is of clinical relevance as a prognostic biomarker and as a companion diagnostic for TF-directed therapies currently under clinical development. Factor VII (FVII) is the natural ligand to TF. The purpose of this study was to investigate the possibility of using active site-inhibited FVII (FVIIai) labeled with (64)Cu for PET imaging of TF expression. FVIIai was conjugated to 2-S-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid (p-SCN-Bn-NOTA) and labeled with (64)Cu ((64)Cu-NOTA-FVIIai). Longitudinal in vivo PET imaging was performed at 1, 4, 15, and 36 h after injection of (64)Cu-NOTA-FVIIai in mice with pancreatic adenocarcinomas (BxPC-3). The specificity of TF imaging with (64)Cu-NOTA-FVIIai was investigated in subcutaneous pancreatic tumor models with different levels of TF expression and in a competition experiment. In addition, imaging of orthotopic pancreatic tumors was performed using (64)Cu-NOTA-FVIIai and PET/MRI. In vivo imaging data were supported by ex vivo biodistribution, flow cytometry, and immunohistochemistry. Longitudinal PET imaging with (64)Cu-NOTA-FVIIai showed a tumor uptake of 2.3 ± 0.2, 3.7 ± 0.3, 3.4 ± 0.3, and 2.4 ± 0.3 percentage injected dose per gram at 1, 4, 15, and 36 h after injection, respectively. An increase in tumor-to-normal-tissue contrast was observed over the imaging time course. Competition with unlabeled FVIIai significantly (P < 0.001) reduced the tumor uptake. The tumor uptake observed in models with different TF expression levels was significantly different from each other (P < 0.001) and was in agreement with the TF level evaluated by TF immunohistochemistry staining. Orthotopic tumors were clearly visible on the PET/MR images, and the uptake of (64)Cu-NOTA-FVIIai was colocalized with viable tumor tissue. (64)Cu-NOTA-FVIIai is well suited for PET imaging of tumor TF expression, and imaging is capable of distinguishing the TF expression level of various pancreatic tumor models. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
A new assessment model for tumor heterogeneity analysis with [18]F-FDG PET images.
Wang, Ping; Xu, Wengui; Sun, Jian; Yang, Chengwen; Wang, Gang; Sa, Yu; Hu, Xin-Hua; Feng, Yuanming
2016-01-01
It has been shown that the intratumor heterogeneity can be characterized with quantitative analysis of the [18]F-FDG PET image data. The existing models employ multiple parameters for feature extraction which makes it difficult to implement in clinical settings for the quantitative characterization. This article reports an easy-to-use and differential SUV based model for quantitative assessment of the intratumor heterogeneity from 3D [18]F-FDG PET image data. An H index is defined to assess tumor heterogeneity by summing voxel-wise distribution of differential SUV from the [18]F-FDG PET image data. The summation is weighted by the distance of SUV difference among neighboring voxels from the center of the tumor and can thus yield increased values for tumors with peripheral sub-regions of high SUV that often serves as an indicator of augmented malignancy. Furthermore, the sign of H index is used to differentiate the rate of change for volume averaged SUV from its center to periphery. The new model with the H index has been compared with a widely-used model of gray level co-occurrence matrix (GLCM) for image texture characterization with phantoms of different configurations and the [18]F-FDG PET image data of 6 lung cancer patients to evaluate its effectiveness and feasibility for clinical uses. The comparison of the H index and GLCM parameters with the phantoms demonstrate that the H index can characterize the SUV heterogeneity in all of 6 2D phantoms while only 1 GLCM parameter can do for 1 and fail to differentiate for other 2D phantoms. For the 8 3D phantoms, the H index can clearly differentiate all of them while the 4 GLCM parameters provide complicated patterns in the characterization. Feasibility study with the PET image data from 6 lung cancer patients show that the H index provides an effective single-parameter metric to characterize tumor heterogeneity in terms of the local SUV variation, and it has higher correlation with tumor volume change after radiotherapy (R(2) = 0.83) than the 4 GLCM parameters (R(2) = 0.63, 0.73, 0.59 and 0.75 for Energy, Contrast, Local Homogeneity and Entropy respectively). The new model of the H index has the capacity to characterize the intratumor heterogeneity feature from 3D [18]F-FDG PET image data. As a single parameter with an intuitive definition, the H index offers potential for clinical applications.
Xia, Chenjie; Makaretz, Sara J; Caso, Christina; McGinnis, Scott; Gomperts, Stephen N; Sepulcre, Jorge; Gomez-Isla, Teresa; Hyman, Bradley T; Schultz, Aaron; Vasdev, Neil; Johnson, Keith A; Dickerson, Bradford C
2017-04-01
Previous postmortem studies have long demonstrated that neurofibrillary tangles made of hyperphosphorylated tau proteins are closely associated with Alzheimer disease clinical phenotype and neurodegeneration pattern. Validating these associations in vivo will lead to new diagnostic tools for Alzheimer disease and better understanding of its neurobiology. To examine whether topographical distribution and severity of hyperphosphorylated tau pathologic findings measured by fluorine 18-labeled AV-1451 ([18F]AV-1451) positron emission tomographic (PET) imaging are linked with clinical phenotype and cortical atrophy in patients with Alzheimer disease. This observational case series, conducted from July 1, 2012, to July 30, 2015, in an outpatient referral center for patients with neurodegenerative diseases, included 6 patients: 3 with typical amnesic Alzheimer disease and 3 with atypical variants (posterior cortical atrophy, logopenic variant primary progressive aphasia, and corticobasal syndrome). Patients underwent [18F]AV-1451 PET imaging to measure tau burden, carbon 11-labeled Pittsburgh Compound B ([11C]PiB) PET imaging to measure amyloid burden, and structural magnetic resonance imaging to measure cortical thickness. Seventy-seven age-matched controls with normal cognitive function also underwent structural magnetic resonance imaging but not tau or amyloid PET imaging. Tau burden, amyloid burden, and cortical thickness. In all 6 patients (3 women and 3 men; mean age 61.8 years), the underlying clinical phenotype was associated with the regional distribution of the [18F]AV-1451 signal. Furthermore, within 68 cortical regions of interest measured from each patient, the magnitude of cortical atrophy was strongly correlated with the magnitude of [18F]AV-1451 binding (3 patients with amnesic Alzheimer disease, r = -0.82; P < .001; r = -0.70; P < .001; r = -0.58; P < .001; and 3 patients with nonamnesic Alzheimer disease, r = -0.51; P < .001; r = -0.63; P < .001; r = -0.70; P < .001), but not of [11C]PiB binding. These findings provide further in vivo evidence that distribution of the [18F]AV-1451 signal as seen on results of PET imaging is a valid marker of clinical symptoms and neurodegeneration. By localizing and quantifying hyperphosphorylated tau in vivo, results of tau PET imaging will likely serve as a key biomarker that links a specific type of molecular Alzheimer disease neuropathologic condition with clinically significant neurodegeneration, which will likely catalyze additional efforts to develop disease-modifying therapeutics.
Kamei, Noriyasu; Morishita, Mariko; Kanayama, Yousuke; Hasegawa, Koki; Nishimura, Mie; Hayashinaka, Emi; Wada, Yasuhiro; Watanabe, Yasuyoshi; Takayama, Kozo
2010-08-17
Molecular imaging technique by use of positron emission tomography (PET) is a noninvasive tool that allows one to quantitatively analyze the function of endogenous molecules and the pharmacokinetics of therapeutic agents in vivo. This technique is expected to be useful for evaluating the effectiveness of diverse drug delivery systems. We demonstrated previously that intestinal insulin absorption is increased significantly by coadministration of cell-penetrating peptides (CPPs), which are taken up effectively by several cells. However, the distribution behavior of insulin whose absorption is increased by CPPs is not clear. We used PET imaging and quantitatively analyzed the intestinal absorption and subsequent distribution of insulin and the effect of CPPs on its absorption and distribution. An unlabeled insulin solution containing tracer insulin, (68)Ga-DOTA-insulin, was administered with or without CPPs into a rat ileal closed loop. PET imaging showed that the CPPs, particularly D-R8 and L-penetratin, significantly increased the (68)Ga-DOTA-insulin level in the liver, kidney, and circulation. After absorption from the intestine, the (68)Ga-DOTA-insulin passed rapidly through the liver and accumulated in the kidney. The increase in the hepatic and renal distribution of (68)Ga-DOTA-insulin by each CPP coadministration was similar manner as that in intestinal absorption, suggesting that the increased accumulation of insulin in the liver and kidney induced by coadministration of CPPs was associated with the increased intestinal absorption of insulin. This is the first study to show that PET imaging enables one to quantitatively analyze the distribution behavior of intestinally absorbed insulin in several organs. This imaging methodology is likely to be useful for developing effective drug delivery systems targeted to specific organs. Copyright 2010 Elsevier B.V. All rights reserved.
Zullo, Letizia; Buschiazzo, Ambra; Massollo, Michela; Riondato, Mattia; Democrito, Alessia; Marini, Cecilia; Benfenati, Fabio; Sambuceti, Gianmario
2018-03-09
This study aimed at developing a method for administration of 18 F-Fludeoxyglucose ( 18 F-FDG) in the common octopus and micro-positron emission tomography (micro-PET) bio-distribution assay for the characterization of glucose metabolism in body organs and regenerating tissues. Methods: Seven animals (two with one regenerating arm) were anesthetized with 3.7% MgCl 2 in artificial seawater. Each octopus was injected with 18-30 MBq of isosmotic 18 F-FDG by accessing the branchial heart or the anterior vena cava. After an uptake time of ~50 minutes, the animal was sacrificed, placed on a bed of a micro-PET scanner and submitted to 10 min static 3-4 bed acquisitions to visualize the entire body. To confirm the interpretation of images, internal organs of interest were collected. The level of radioactivity of each organ was counted with a γ-counter. Results: Micro-PET scanning documented a good 18 F-FDG full body distribution following vena cava administration. A high mantle mass radioactivity facing a relatively low tracer uptake in the arms was revealed. In particular, the following organs were clearly identified and measured for their uptake: brain (standardized uptake value, SUV max of 6.57±1.86), optic lobes (SUV max of 7.59±1.66) and arms (SUV max of 1.12±0.06). Interestingly, 18 F-FDG uptake was up to threefold higher in the regenerating arm stumps at the level of highly proliferating areas. Conclusion: This study represents a stepping-stone over the use of non-invasive functional techniques to address questions relevant to invertebrate neuroscience and regenerative medicine. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Yang, Zhi; Xiong, Chiyi; Zhang, Rui; Zhu, Hua; Li, Chun
2012-01-01
The purposes of this study were to develop an efficient method of labeling D-glucosamine hydrochloride with gallium 68 (68Ga) and investigate the imaging properties of the resulting radiotracer in a human tumor xenograft model using micro-positron emission tomography (μPET). The precursor compound 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-2-deoxy-D-glucosamine (DOTA-DG) was synthesized from D-glucosamine hydrochloride and 2-(4-isothiocyanatobenzyl)-DOTA. Radiolabeling of DOTA-DG with 68Ga was achieved in 10 minutes using microwave heating. The labeling efficiency a nd radiochemical purity after purification of 68Ga-DOTA-DG were ~85% and greater than 98%, respectively. In A431 cells, the percentages of 68Ga-DOTA-DG and 18F-FDG uptakes after 60 min incubation were 15.7% and 16.2%, respectively. In vivo, the mean ± standard deviation of 68Ga-DOTADG uptake values in A431 tumors were 2.38±0.30, 0.75±0.13, and 0.39±0.04 percent of the injected dose per gram of tissue at 10, 30, and 60 minutes after intravenous injection, respectively. μPET imaging of A431-bearing mice clearly delineated tumors at 60 minutes after injection of 68Ga-DOTA-DG at a dose of 3.7 MBq. 68Ga-DOTA-DG displayed significantly higher tumor-to-heart, tumor-to-brain, and tumor-to-muscle ratios than 18F-FDG did. Further studies are needed to identify the mechanism of tumor uptake of this new glucosamine-based PET imaging tracer. PMID:23145365
Yang, Zhi; Xiong, Chiyi; Zhang, Rui; Zhu, Hua; Li, Chun
2012-01-01
The purposes of this study were to develop an efficient method of labeling D-glucosamine hydrochloride with gallium 68 ((68)Ga) and investigate the imaging properties of the resulting radiotracer in a human tumor xenograft model using micro-positron emission tomography (μPET). The precursor compound 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-2-deoxy-D-glucosamine (DOTA-DG) was synthesized from D-glucosamine hydrochloride and 2-(4-isothiocyanatobenzyl)-DOTA. Radiolabeling of DOTA-DG with (68)Ga was achieved in 10 minutes using microwave heating. The labeling efficiency a nd radiochemical purity after purification of (68)Ga-DOTA-DG were ~85% and greater than 98%, respectively. In A431 cells, the percentages of (68)Ga-DOTA-DG and (18)F-FDG uptakes after 60 min incubation were 15.7% and 16.2%, respectively. In vivo, the mean ± standard deviation of (68)Ga-DOTADG uptake values in A431 tumors were 2.38±0.30, 0.75±0.13, and 0.39±0.04 percent of the injected dose per gram of tissue at 10, 30, and 60 minutes after intravenous injection, respectively. μPET imaging of A431-bearing mice clearly delineated tumors at 60 minutes after injection of (68)Ga-DOTA-DG at a dose of 3.7 MBq. (68)Ga-DOTA-DG displayed significantly higher tumor-to-heart, tumor-to-brain, and tumor-to-muscle ratios than (18)F-FDG did. Further studies are needed to identify the mechanism of tumor uptake of this new glucosamine-based PET imaging tracer.
MIRBOLOOKI, M. REZA; CONSTANTINESCU, CRISTIAN C.; PAN, MIN-LIANG; MUKHERJEE, JOGESHWAR
2013-01-01
Brown adipose tissue (BAT) plays a significant role in metabolism. In this study, we report the use of atomoxetine (a clinically applicable norepinephrine reuptake inhibitor) for 18F-FDG PET imaging of BAT and its effects on heat production and blood glucose concentration. Fasted-male Sprague-Dawley rats were administered with intravenous 18F-FDG. The same rats were treated with atomoxetine (0.1 mg/kg, i.v.) 30 min before 18F-FDG administration. To confirm the β-adrenergic effects, propranolol (β-adrenergic inhibitor) 5 mg/kg was given intraperitoneally 30 min prior to atomoxetine administration. The effect of atomoxetine on BAT metabolism was assessed in fasted and non-fasted rats and on BAT temperature and blood glucose in fasted rats. In 18F-FDG PET/CT images, interscapular BAT (IBAT) and other areas of BAT were clearly visualized. When rats were fasted, atomoxetine (0.1 mg/kg) increased the 18F-FDG uptake of IBAT by factor of 24 within 30 min. Propranolol reduced the average 18F-FDG uptake of IBAT significantly. Autoradiography of IBAT and white adipose tissue confirmed the data obtained by PET. When rats were not fasted, atomoxetine-induced increase of 18F-FDG uptake in IBAT was delayed and occurred in 120 min. For comparison, direct stimulation of β3-adrenreceptors in non-fasted rats with CL-316, 243 occurred within 30 min. Atomoxetine-induced IBAT activation was associated with higher IBAT temperature and lower blood glucose. This was mediated by inhibition of norepinephrine reuptake transporters in IBAT leading to increased norepinephrine concentration in the synapse. Increased synaptic norepinephrine activates β3-adrenreceptors resulting in BAT hypermetabolism that is visible and quantifiable by 18F-FDG PET/CT. PMID:23080264
Synthesis and preclinical characterization of [18F]FPBZA: a novel PET probe for melanoma.
Wu, Shih-Yen; Huang, Shih-Pin; Lo, Yen-Chen; Liu, Ren-Shyan; Wang, Shyh-Jen; Lin, Wuu-Jyh; Shen, Chih-Chieh; Wang, Hsin-Ell
2014-01-01
Benzamide can specifically bind to melanoma cells. A 18F-labeled benzamide derivative, [18F]N-(2-diethylaminoethyl)-4-[2-(2-(2-fluoroethoxy) ethoxy)ethoxy]benzamide ([18F]FPBZA), was developed as a promising PET probe for primary and metastatic melanoma. [18F]FPBZA was synthesized via a one-step radiofluorination in this study. The specific uptake of [18F]FPBZA was studied in B16F0 melanoma cells, A375 amelanotic melanoma cells, and NB-DNJ-pretreated B16F0 melanoma cells. The biological characterization of [18F]FPBZA was performed on mice bearing B16F0 melanoma, A375 amelanotic melanoma, or inflammation lesion. [18F]FPBZA can be prepared efficiently with a yield of 40-50%. The uptake of [18F]FPBZA by B16F0 melanoma cells was significantly higher than those by A375 tumor cells and NB-DNJ-pretreated B16F0 melanoma cells. B16F0 melanoma displayed prominent uptake of [18F]FPBZA at 2 h (7.81±0.82%ID/g), compared with A375 tumor and inflammation lesion (3.00±0.71 and 1.67±0.56%ID/g, resp.). [18F]FPBZA microPET scan clearly delineated B16F0 melanoma but not A375 tumor and inflammation lesion. In mice bearing pulmonary metastases, the lung radioactivity reached 4.77±0.36%ID/g at 2 h (versus 1.16±0.23%ID/g in normal mice). Our results suggested that [18F]FPBZA PET would provide a promising and specific approach for the detection of primary and metastatic melanoma lesions.
Development of an MRI-compatible digital SiPM detector stack for simultaneous PET/MRI
Düppenbecker, Peter M; Weissler, Bjoern; Gebhardt, Pierre; Schug, David; Wehner, Jakob; Marsden, Paul K; Schulz, Volkmar
2016-01-01
Abstract Advances in solid-state photon detectors paved the way to combine positron emission tomography (PET) and magnetic resonance imaging (MRI) into highly integrated, truly simultaneous, hybrid imaging systems. Based on the most recent digital SiPM technology, we developed an MRI-compatible PET detector stack, intended as a building block for next generation simultaneous PET/MRI systems. Our detector stack comprises an array of 8 × 8 digital SiPM channels with 4 mm pitch using Philips Digital Photon Counting DPC 3200-22 devices, an FPGA for data acquisition, a supply voltage control system and a cooling infrastructure. This is the first detector design that allows the operation of digital SiPMs simultaneously inside an MRI system. We tested and optimized the MRI-compatibility of our detector stack on a laboratory test bench as well as in combination with a Philips Achieva 3 T MRI system. Our design clearly reduces distortions of the static magnetic field compared to a conventional design. The MRI static magnetic field causes weak and directional drift effects on voltage regulators, but has no direct impact on detector performance. MRI gradient switching initially degraded energy and timing resolution. Both distortions could be ascribed to voltage variations induced on the bias and the FPGA core voltage supply respectively. Based on these findings, we improved our detector design and our final design shows virtually no energy or timing degradations, even during heavy and continuous MRI gradient switching. In particular, we found no evidence that the performance of the DPC 3200-22 digital SiPM itself is degraded by the MRI system. PMID:28458919
Synthesis and Preclinical Characterization of [18F]FPBZA: A Novel PET Probe for Melanoma
Huang, Shih-Pin; Lo, Yen-Chen; Liu, Ren-Shyan; Shen, Chih-Chieh
2014-01-01
Introduction. Benzamide can specifically bind to melanoma cells. A 18F-labeled benzamide derivative, [18F]N-(2-diethylaminoethyl)-4-[2-(2-(2-fluoroethoxy) ethoxy)ethoxy]benzamide ([18F]FPBZA), was developed as a promising PET probe for primary and metastatic melanoma. Methods. [18F]FPBZA was synthesized via a one-step radiofluorination in this study. The specific uptake of [18F]FPBZA was studied in B16F0 melanoma cells, A375 amelanotic melanoma cells, and NB-DNJ-pretreated B16F0 melanoma cells. The biological characterization of [18F]FPBZA was performed on mice bearing B16F0 melanoma, A375 amelanotic melanoma, or inflammation lesion. Results. [18F]FPBZA can be prepared efficiently with a yield of 40–50%. The uptake of [18F]FPBZA by B16F0 melanoma cells was significantly higher than those by A375 tumor cells and NB-DNJ-pretreated B16F0 melanoma cells. B16F0 melanoma displayed prominent uptake of [18F]FPBZA at 2 h (7.81 ± 0.82 %ID/g), compared with A375 tumor and inflammation lesion (3.00 ± 0.71 and 1.67 ± 0.56 %ID/g, resp.). [18F]FPBZA microPET scan clearly delineated B16F0 melanoma but not A375 tumor and inflammation lesion. In mice bearing pulmonary metastases, the lung radioactivity reached 4.77 ± 0.36 %ID/g at 2 h (versus 1.16 ± 0.23 %ID/g in normal mice). Conclusions. Our results suggested that [18F]FPBZA PET would provide a promising and specific approach for the detection of primary and metastatic melanoma lesions. PMID:25254219
Usuda, Katsuo; Funasaki, Aika; Sekimura, Atsushi; Motono, Nozomu; Matoba, Munetaka; Doai, Mariko; Yamada, Sohsuke; Ueda, Yoshimichi; Uramoto, Hidetaka
2018-04-09
Diffusion-weighted magnetic resonance imaging (DWI) is useful for detecting malignant tumors and the assessment of lymph nodes, as FDG-PET/CT is. But it is not clear how DWI influences the prognosis of lung cancer patients. The focus of this study is to evaluate the correlations between maximum standardized uptake value (SUVmax) of FDG-PET/CT and apparent diffusion coefficient (ADC) value of DWI with known prognostic factors in resected lung cancer. A total of 227 patients with resected lung cancers were enrolled in this study. FEG-PET/CT and DWI were performed in each patient before surgery. There were 168 patients with adenocarcinoma, 44 patients with squamous cell carcinoma, and 15 patients with other cell types. SUVmax was a factor that was correlated to T factor, N factor, or cell differentiation. ADC of lung cancer was a factor that was not correlated to T factor, or N factor. There was a significantly weak inverse relationship between SUVmax and ADC (Correlation coefficient r = - 0.227). In analysis of survival, there were significant differences between the categories of sex, age, pT factor, pN factor, cell differentiation, cell type, and SUVmax. Univariate analysis revealed that SUVmax, pN factor, age, cell differentiation, cell type, sex, and pT factor were significant factors. Multivariate analysis revealed that SUVmax and pN factor were independent significant prognostic factors. SUVmax was a significant prognostic factor that is correlated to T factor, N factor, or cell differentiation, but ADC was not. SUVmax may be more useful for predicting the prognosis of lung cancer than ADC values.
Yusufi, Nahid; Mall, Sabine; Bianchi, Henrique de Oliveira; Steiger, Katja; Reder, Sybille; Klar, Richard; Audehm, Stefan; Mustafa, Mona; Nekolla, Stephan; Peschel, Christian; Schwaiger, Markus; Krackhardt, Angela M; D'Alessandria, Calogero
2017-01-01
A number of different technologies have been developed to monitor in vivo the distribution of gene-modified T cells used in immunotherapy. Nevertheless, in-depth characterization of novel approaches with respect to sensitivity and clinical applicability are so far missing. We have previously described a novel method to track engineered human T cells in tumors using 89 Zr-Df-aTCRmu-F(ab') 2 targeting the murinized part of the TCR beta domain (TCRmu) of a transgenic TCR. Here, we performed an in-depth in vitro characterization of the tracer in terms of antigen affinity, immunoreactivity, influence on T-cell functionality and stability in vitro and in vivo . Of particular interest, we have developed diverse experimental settings to quantify TCR-transgenic T cells in vivo . Local application of 89 Zr-Df-aTCRmu-F(ab') 2 -labeled T cells in a spot-assay revealed signal detection down to approximately 1.8x10 4 cells. In a more clinically relevant model, NSG mice were intravenously injected with different numbers of transgenic T cells, followed by injection of the 89 Zr-Df-aTCRmu-F(ab') 2 tracer, PET/CT imaging and subsequent ex vivo T-cell quantification in the tumor. Using this setting, we defined a comparable detection limit of 1.0x10 4 T cells. PET signals correlated well to total numbers of transgenic T cells detected ex vivo independently of the engraftment rates observed in different individual experiments. Thus, these findings confirm the high sensitivity of our novel PET/CT T-cell tracking method and provide critical information about the quantity of transgenic T cells in the tumor environment suggesting our technology being highly suitable for further clinical translation.
NASA Astrophysics Data System (ADS)
Kovács, Attila; Unger, János; Gál, Csilla V.; Kántor, Noémi
2016-07-01
This study introduces new methodological concepts for integrating seasonal subjective thermal assessment patterns of people into the thermal components of two tourism climatological evaluation tools: the Tourism Climatic Index (TCI) and the Climate-Tourism/Transfer-Information-Scheme (CTIS). In the case of the TCI, we replaced the air temperature and relative humidity as the basis of the initial rating system with the physiologically equivalent temperature (PET)—a complex human biometeorological index. This modification improves the TCI's potential to evaluate the thermal aspects of climate. The major accomplishments of this study are (a) the development of a new, PET-based rating system and its integration into the thermal sub-indices of the TCI and (b) the regionalization of the thermal components of CTIS to reflect both the thermal sensation and preference patterns of people. A 2-year-long (2011-2012) thermal comfort survey conducted in Szeged, Hungary, from spring to autumn was utilized to demonstrate the implementation of the introduced concepts. We found considerable differences between the thermal perception and preference patterns of Hungarians, with additional variations across the evaluated seasons. This paper describes the proposed methodology for the integration of the new seasonal, perception-based, and preference-based PET rating systems into the TCI, and presents the incorporation of new PET thresholds into the CTIS. In order to demonstrate the utility of the modified evaluation tools, we performed case study climate analyses for three Hungarian tourist destinations. The additional adjustments introduced during the course of those analyses include the reduction of TCI's temporal resolution to 10-day intervals and the exclusion of nocturnal and winter periods from the investigation.
Reiman, Eric M.; Chen, Kewei; Langbaum, Jessica B.S.; Lee, Wendy; Reschke, Cole; Bandy, Daniel; Alexander, Gene E.; Caselli, Richard J.
2010-01-01
Epidemiological studies suggest that higher midlife serum total cholesterol levels are associated with an increased risk of Alzheimer’s disease (AD). Using fluorodeoxyglucose positron emission tomography (PET) in the study of cognitively normal late-middle-aged people, we demonstrated an association between apolipoprotein E (APOE) ε4 gene dose, the major genetic risk factor for late-onset AD, and lower measurements of the cerebral metabolic rate for glucose (CMRgl) in AD-affected brain regions, we proposed using PET as a presymptomatic endophenotype to evaluate other putative AD risk modifiers, and we then used it to support an aggregate cholesterol-related genetic risk score in the risk of AD. In the present study, we used PET to investigate the association between serum total cholesterol levels and cerebral metabolic rate for glucose metabolism (CMRgl) in 117 cognitively normal late middle-aged APOE ε4 homozygotes, heterozygotes and noncarriers. Higher serum total cholesterol levels were associated with lower CMRgl bilaterally in precuneus, parietotemporal and prefrontal regions previously found to be preferentially affected by AD, and in additional frontal regions previously found to be preferentially affected by normal aging. The associations were greater in APOE ε4 carriers than non-carriers in some of the AD-affected brain regions. We postulate the higher midlife serum total cholesterol levels accelerate brain processes associated with normal aging and conspire with other risk factors in the predisposition to AD. We propose using PET in proof-of-concept randomized controlled trials to rapidly evaluate the effects of midlife cholesterol-lowering treatments on the brain changes associated with normal aging and AD. PMID:19631758
Cho, Kyu-Hyang; Do, Jun-Young; Park, Jong-Won; Yoon, Kyung-Woo; Kim, Yong-Lim
2013-01-01
Several studies have reported benefits for human peritoneal mesothelial cell function of a neutral-pH dialysate low in glucose degradation products (GDPs). However, the effects of low-GDP solution on ultrafiltration (UF), transport of solutes, and control of body water remain elusive. We therefore investigated the effect of low-GDP solution on UF, solute transport, and control of body water. Among 79 new continuous ambulatory peritoneal dialysis (CAPD) patients, 60 completed a 12-month protocol (28 in a lactate-based high-GDP solution group, 32 in a lactate-based low-GDP solution group). Clinical indices--including 24-hour UF volume (UFV), 24-hour urine volume (UV), residual renal function, and dialysis adequacy--were measured at months 1, 6, and 12. At months 1, 6, and 12, UFV, glucose absorption, 4-hour dialysate-to-plasma (D/P) creatinine, and 1-hour D/P Na(+) were assessed during a modified 4.25% peritoneal equilibration test (PET). Body composition by bioelectric impedance analysis was measured at months 1 and 12 in 26 CAPD patients. Daily UFV was lower in the low-GDP group. Despite similar solute transport and aquaporin function, the low-GDP group also showed lower UFV and higher glucose absorption during the PET. Factors associated with UFV during the PET were lactate-based high-GDP solution and 1-hour D/P Na(+). No differences in volume status and obesity at month 12 were observed, and improvements in hypervolemia were equal in both groups. Compared with the high-GDP group, the low-GDP group had a lower UFV during a PET and a lower daily UFV during the first year after peritoneal dialysis initiation. Although the low-GDP group had a lower daily UFV, no difficulties in controlling edema were encountered.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-02
... Organizations; ICE Clear Credit LLC; Order Approving Proposed Rule Change, as Modified by Amendments No. 1 and 2 Thereto, To Update Chapter 26 and Remove Schedule 502 of the ICE Clear Credit Rules March 27, 2013. I. Introduction On January 31, 2013, ICE Clear Credit LLC (``ICC'') filed with the Securities and Exchange...
Achieving a new controllable male contraception by the photothermal effect of gold nanorods.
Li, Wen-qing; Sun, Chun-yang; Wang, Feng; Wang, Yu-cai; Zhai, Yi-wen; Liang, Meng; Liu, Wen-jing; Liu, Zhi-min; Wang, Jun; Sun, Fei
2013-06-12
During the process of human civilization, owning household pets has become increasingly popular. However, dogs and cats may be reservoirs or vectors of transmissible diseases to humans. Confronted with the overpopulation of pets, traditional contraception methods, surgical methods of sterilization, for animals are used, namely, ovariohysterectomy and orchidectomy. Therefore, a simple, nonsurgical, controllable, more effective and less expensive contraception method is highly desirable. In this study, we show that in situ testicular injection of methoxy poly(ethylene glycol)-modified gold nanorods with near-infrared irradiation in male mice can achieve short-lived or permanent male infertility. In a lower hyperthermia treatment, the morphology of testes and seminiferous tubules is only partly injured, and fertility indices are decreased to 10% at day 7, then recovered to 50% at day 60. In a higher hyperthermia treatment, the morphology of testes and seminiferous tubules are totally destroyed, and fertility indices are decreased to 0 at day 7. Overall, our results indicate a potential application of plasmonic nanomaterials for male contraception.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-05
... Organizations; Options Clearing Corporation; Order Approving Proposed Rule Change, as Modified by Amendments No... September 21, 2011, the Options Clearing Corporation (``OCC'') filed with the Securities and Exchange... OMX PHLX has proposed to trade options on indexes (``Alpha Index Options'') that measure the relative...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-08
... Organizations; The Options Clearing Corporation; Order Approving Proposed Rule Change, as Modified by Amendment No. 1 Thereto, Relating to the Margining of Segregated Futures Customer Accounts on a Gross Basis November 2, 2012. I. Introduction On September 14, 2012, The Options Clearing Corporation (``OCC'') filed...
Besemer, Abigail E; Titz, Benjamin; Grudzinski, Joseph J; Weichert, Jamey P; Kuo, John S; Robins, H Ian; Hall, Lance T; Bednarz, Bryan P
2017-07-06
Variations in tumor volume segmentation methods in targeted radionuclide therapy (TRT) may lead to dosimetric uncertainties. This work investigates the impact of PET and MRI threshold-based tumor segmentation on TRT dosimetry in patients with primary and metastatic brain tumors. In this study, PET/CT images of five brain cancer patients were acquired at 6, 24, and 48 h post-injection of 124 I-CLR1404. The tumor volume was segmented using two standardized uptake value (SUV) threshold levels, two tumor-to-background ratio (TBR) threshold levels, and a T1 Gadolinium-enhanced MRI threshold. The dice similarity coefficient (DSC), jaccard similarity coefficient (JSC), and overlap volume (OV) metrics were calculated to compare differences in the MRI and PET contours. The therapeutic 131 I-CLR1404 voxel-level dose distribution was calculated from the 124 I-CLR1404 activity distribution using RAPID, a Geant4 Monte Carlo internal dosimetry platform. The TBR, SUV, and MRI tumor volumes ranged from 2.3-63.9 cc, 0.1-34.7 cc, and 0.4-11.8 cc, respectively. The average ± standard deviation (range) was 0.19 ± 0.13 (0.01-0.51), 0.30 ± 0.17 (0.03-0.67), and 0.75 ± 0.29 (0.05-1.00) for the JSC, DSC, and OV, respectively. The DSC and JSC values were small and the OV values were large for both the MRI-SUV and MRI-TBR combinations because the regions of PET uptake were generally larger than the MRI enhancement. Notable differences in the tumor dose volume histograms were observed for each patient. The mean (standard deviation) 131 I-CLR1404 tumor doses ranged from 0.28-1.75 Gy GBq -1 (0.07-0.37 Gy GBq -1 ). The ratio of maximum-to-minimum mean doses for each patient ranged from 1.4-2.0. The tumor volume and the interpretation of the tumor dose is highly sensitive to the imaging modality, PET enhancement metric, and threshold level used for tumor volume segmentation. The large variations in tumor doses clearly demonstrate the need for standard protocols for multimodality tumor segmentation in TRT dosimetry.
NASA Astrophysics Data System (ADS)
Besemer, Abigail E.; Titz, Benjamin; Grudzinski, Joseph J.; Weichert, Jamey P.; Kuo, John S.; Robins, H. Ian; Hall, Lance T.; Bednarz, Bryan P.
2017-08-01
Variations in tumor volume segmentation methods in targeted radionuclide therapy (TRT) may lead to dosimetric uncertainties. This work investigates the impact of PET and MRI threshold-based tumor segmentation on TRT dosimetry in patients with primary and metastatic brain tumors. In this study, PET/CT images of five brain cancer patients were acquired at 6, 24, and 48 h post-injection of 124I-CLR1404. The tumor volume was segmented using two standardized uptake value (SUV) threshold levels, two tumor-to-background ratio (TBR) threshold levels, and a T1 Gadolinium-enhanced MRI threshold. The dice similarity coefficient (DSC), jaccard similarity coefficient (JSC), and overlap volume (OV) metrics were calculated to compare differences in the MRI and PET contours. The therapeutic 131I-CLR1404 voxel-level dose distribution was calculated from the 124I-CLR1404 activity distribution using RAPID, a Geant4 Monte Carlo internal dosimetry platform. The TBR, SUV, and MRI tumor volumes ranged from 2.3-63.9 cc, 0.1-34.7 cc, and 0.4-11.8 cc, respectively. The average ± standard deviation (range) was 0.19 ± 0.13 (0.01-0.51), 0.30 ± 0.17 (0.03-0.67), and 0.75 ± 0.29 (0.05-1.00) for the JSC, DSC, and OV, respectively. The DSC and JSC values were small and the OV values were large for both the MRI-SUV and MRI-TBR combinations because the regions of PET uptake were generally larger than the MRI enhancement. Notable differences in the tumor dose volume histograms were observed for each patient. The mean (standard deviation) 131I-CLR1404 tumor doses ranged from 0.28-1.75 Gy GBq-1 (0.07-0.37 Gy GBq-1). The ratio of maximum-to-minimum mean doses for each patient ranged from 1.4-2.0. The tumor volume and the interpretation of the tumor dose is highly sensitive to the imaging modality, PET enhancement metric, and threshold level used for tumor volume segmentation. The large variations in tumor doses clearly demonstrate the need for standard protocols for multimodality tumor segmentation in TRT dosimetry.
Ethno-ornithology and conservation of wild birds in the semi-arid Caatinga of northeastern Brazil.
Alves, Rômulo Romeu Nóbrega; Leite, Railson Cidennys Lourenço; Souto, Wedson Medeiros Silva; Bezerra, Dandara M M; Loures-Ribeiro, Alan
2013-02-27
The utilization of birds as pets has been recognized as one of the principal threats to global avifauna. Most of the information about the use and sale of birds as pets has been limited to areas of high biodiversity and whose impacts of anthropic actions have been widely broadcast internationally, for example for the Amazon Forest and forest remnants of Southeast Asia. The Caatinga predominates in the semi-arid region of Brazil, and is one of the semi-arid biomes with the greatest biological diversity in the world, where 511 species of birds exist. Many of these birds are used as pets, a common practice in the region, which has important conservationist implications but has been little studied. Therefore, the aim of the present study was to detail aspects of the use of birds as pets in a locality in the semi-arid region of Northeast Brazil. Information on the use of avifauna was obtained through interviews and visits to the homes of 78 wild bird keepers. A total of 41 species of birds were recorded, mostly of the families Emberizidae (n = 9 species), Columbidae (n = 7 species), Icteridae (n = 6 species) and Psittacidae (n = 3 species). The birds that were most often recorded were Paroaria dominicana (n = 79 especimens), Sporophila albogularis (n = 67), Aratinga cactorum (n = 49), Sporophila lineola (n = 36), Sicalis flaveola (n = 29) and Sporophila nigricollis (n = 27). The use of wild birds in the area studied, as an example of what occurs in other places in the semi-arid Northeast, demonstrates that such activities persist in the region, in spite of being illegal, and have been happening in clandestine or semi-clandestine manner. No statistically significant correlation were found between socioeconomic factors and keeping birds as pets reflects the cultural importance of this practice of rearing wild birds for pets in the region, which is widespread among the local population, independent of socioeconomic factors. Obviously, human pressure on the avifauna exploited has ecological implications and makes it clear that conservationist measures should consider the cultural, economic and social aspects of these practices. These measures should be carried out by both directly combating the illegal traffic of animals and promoting educational campaigns aimed at all the players involved, from the collectors up to the consumer and wild bird keepers.
Optimizing modelling in iterative image reconstruction for preclinical pinhole PET
NASA Astrophysics Data System (ADS)
Goorden, Marlies C.; van Roosmalen, Jarno; van der Have, Frans; Beekman, Freek J.
2016-05-01
The recently developed versatile emission computed tomography (VECTor) technology enables high-energy SPECT and simultaneous SPECT and PET of small animals at sub-mm resolutions. VECTor uses dedicated clustered pinhole collimators mounted in a scanner with three stationary large-area NaI(Tl) gamma detectors. Here, we develop and validate dedicated image reconstruction methods that compensate for image degradation by incorporating accurate models for the transport of high-energy annihilation gamma photons. Ray tracing software was used to calculate photon transport through the collimator structures and into the gamma detector. Input to this code are several geometric parameters estimated from system calibration with a scanning 99mTc point source. Effects on reconstructed images of (i) modelling variable depth-of-interaction (DOI) in the detector, (ii) incorporating photon paths that go through multiple pinholes (‘multiple-pinhole paths’ (MPP)), and (iii) including various amounts of point spread function (PSF) tail were evaluated. Imaging 18F in resolution and uniformity phantoms showed that including large parts of PSFs is essential to obtain good contrast-noise characteristics and that DOI modelling is highly effective in removing deformations of small structures, together leading to 0.75 mm resolution PET images of a hot-rod Derenzo phantom. Moreover, MPP modelling reduced the level of background noise. These improvements were also clearly visible in mouse images. Performance of VECTor can thus be significantly improved by accurately modelling annihilation gamma photon transport.
Li, Junfeng; Zhang, Xiang; Jin, Hongjun; Fan, Jinda; Flores, Hubert; Perlmutter, Joel S.; Tu, Zhude
2015-01-01
A series of fluorine-containing PDE10A inhibitors were designed and synthesized to improve the metabolic stability of [11C]MP-10. Twenty of the 22 new analogues had high potency and selectivity for PDE10A: 18a–j, 19d–j, 20a–b, and 21b had IC50 values <5 nM for PDE10A. Seven F-18 labeled compounds [18F]18a–e, [18F]18g, and [18F]20a were radiosynthesized by 18F-introduction onto the quinoline rather than the pyrazole moiety of the MP-10 pharmacophore and performed in vivo evaluation. Biodistribution studies in rats showed ~2-fold higher activity in the PDE10A-enriched striatum than nontarget brain regions; this ratio increased from 5 to 30 min postinjection, particularly for [18F]18a–d and [18F]20a. Micro-PET studies of [18F]18d and [18F]20a in nonhuman primates provided clear visualization of striatum with suitable equilibrium kinetics and favorable metabolic stability. These results suggest this strategy may identify a 18F-labeled PET tracer for quantifying the levels of PDE10A in patients with CNS disorders including Huntington’s disease and schizophrenia. PMID:26430878
Wieser, Gesche; Mansi, Rosalba; Grosu, Anca L; Schultze-Seemann, Wolfgang; Dumont-Walter, Rebecca A; Meyer, Philipp T; Maecke, Helmut R; Reubi, Jean Claude; Weber, Wolfgang A
2014-01-01
Ex vivo studies have shown that the gastrin releasing peptide receptor (GRPr) is overexpressed on almost all primary prostate cancers, making it a promising target for prostate cancer imaging and targeted radiotherapy. Biodistribution, dosimetry and tumor uptake of the GRPr antagonist ⁶⁴Cu-CB-TE2A-AR06 [(⁶⁴Cu-4,11-bis(carboxymethyl)-1,4,8,11-tetraazabicyclo(6.6.2)hexadecane)-PEG₄-D-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-LeuNH₂] were studied by PET/CT in four patients with newly diagnosed prostate cancer (T1c-T2b, Gleason 6-7). No adverse events were observed after injection of ⁶⁴Cu-CB-TE2A-AR06. Three of four tumors were visualized with high contrast [tumor-to-prostate ratio > 4 at 4 hours (h) post injection (p.i.)], one small tumor (T1c, < 5% tumor on biopsy specimens) showed moderate contrast (tumor-to-prostate ratio at 4 h: 1.9). Radioactivity was cleared by the kidneys and only the pancreas demonstrated significant accumulation of radioactivity, which rapidly decreased over time. ⁶⁴Cu-CB-TE2A-AR06 shows very favorable characteristics for imaging prostate cancer. Future studies evaluating ⁶⁴Cu-CB-TE2A-AR06 PET/CT for prostate cancer detection, staging, active surveillance, and radiation treatment planning are necessary.
Design and performance of a high spatial resolution, time-of-flight PET detector
Krishnamoorthy, Srilalan; LeGeyt, Benjamin; Werner, Matthew E.; Kaul, Madhuri; Newcomer, F. M.; Karp, Joel S.; Surti, Suleman
2014-01-01
This paper describes the design and performance of a high spatial resolution PET detector with time-of-flight capabilities. With an emphasis on high spatial resolution and sensitivity, we initially evaluated the performance of several 1.5 × 1.5 and 2.0 × 2.0 mm2 and 12–15 mm long LYSO crystals read out by several appropriately sized PMTs. Experiments to evaluate the impact of reflector on detector performance were performed and the final detector consisted of a 32 × 32 array of 1.5 × 1.5 × 15 mm3 LYSO crystals packed with a diffuse reflector and read out by a single Hamamatsu 64 channel multi-anode PMT. Such a design made it compact, modular and offered a cost-effective solution to obtaining excellent energy and timing resolution. To minimize the number of readout signals, a compact front-end readout electronics that summed anode signals along each of the orthogonal directions was also developed. Experimental evaluation of detector performance demonstrates clear discrimination of the crystals within the detector. An average energy resolution (FWHM) of 12.7 ± 2.6% and average coincidence timing resolution (FWHM) of 348 ps was measured, demonstrating suitability for use in the development of a high spatial resolution time-of-flight scanner for dedicated breast PET imaging. PMID:25246711
Duraisamy, Navaneethan; Ponniah, Ganeshthangaraj; Jo, Jeongdai; Choi, Kyung-Hyun
2013-08-01
This paper is focused on printed techniques for the fabrication of hybrid structure of silver (Ag) grid/poly(3,4-ethylenedioxythiophene): Poly(styrenesulfonate) (PEDOT:PSS) on polyethylene terepthalate (PET) as a flexible substrate. Ag grid has been printed on PET substrate by using gravure offset printing process, followed by PEDOT:PSS thin film deposition on Ag grid through electrohydrodynamic atomization (EHDA) technique. The important parameters for achieving uniform hybrid structure of Ag grid/PEDOT:PSS through printed techniques have been clearly discussed. Field emission scanning electron microscope studies revealed the uniformity of printed Ag grid with homogeneous deposition of PEDOT:PSS on Ag grid. The optical properties of Ag grid/PEDOT:PSS were measured by UV-visible spectroscopy, which showed nearly 80-82% of transparency in the visible region and it was nearly same as PEDOT:PSS thin film on PET substrate. Current-voltage (I-V) analysis of fabricated hybrid device by using printed Ag grid/PEDOT:PSS as a bottom electrode showed good rectifying behavior with possible interfacial mechanisms. Capacitance-voltage (C-V) analysis was carried over different frequencies. These results suggest that fabrication of hybrid structure through printed techniques will play a significant role in mass production of printed electronic devices for commercial application by using flexible substrate.
Günther, Fritz; Marelli, Marco
2016-01-01
Noun compounds, consisting of two nouns (the head and the modifier) that are combined into a single concept, differ in terms of their plausibility: school bus is a more plausible compound than saddle olive. The present study investigates which factors influence the plausibility of attested and novel noun compounds. Distributional Semantic Models (DSMs) are used to obtain formal (vector) representations of word meanings, and compositional methods in DSMs are employed to obtain such representations for noun compounds. From these representations, different plausibility measures are computed. Three of those measures contribute in predicting the plausibility of noun compounds: The relatedness between the meaning of the head noun and the compound (Head Proximity), the relatedness between the meaning of modifier noun and the compound (Modifier Proximity), and the similarity between the head noun and the modifier noun (Constituent Similarity). We find non-linear interactions between Head Proximity and Modifier Proximity, as well as between Modifier Proximity and Constituent Similarity. Furthermore, Constituent Similarity interacts non-linearly with the familiarity with the compound. These results suggest that a compound is perceived as more plausible if it can be categorized as an instance of the category denoted by the head noun, if the contribution of the modifier to the compound meaning is clear but not redundant, and if the constituents are sufficiently similar in cases where this contribution is not clear. Furthermore, compounds are perceived to be more plausible if they are more familiar, but mostly for cases where the relation between the constituents is less clear. PMID:27732599
Lee, Jong Jin; Chung, Jin Hwa; Kim, Seog-Young
2016-10-01
The present study aimed to investigate the effect of (18)F-fluorodeoxyglucose (FDG) extravasation on the time taken for tumoral uptake to reach a plateau. For the animal experiment, FDG extravasation was conducted in the tails of HCT116 tumor-bearing xenograft mice models in three groups (no extravasation, 40 % extravasation, and 80 % extravasation; n = 5, each). Dynamic positron emission tomography (PET) images were acquired over a period of 2 h following injection. Time-activity curves for FDG in the tails and tumors were calculated. For the clinical experiment, 22 patients (male:female, 14:8; age range, 70.8 ± 9.2 years) were subjected to PET/computed tomography (PET/CT) 1 h after the injection of FDG. The inclusion criteria were as follows: (1) submitted to both whole-body and subsequent regional scanning; (2) entire extravasation activity visualized in the whole-body images; (3) tumor visualized on both whole-body and additional regional images; and (4) status of tumor either confirmed by biopsy or clinically suspected for malignancy. The standardized uptake values (SUVs) of the tumors (on the whole-body and additional PET images) and extravasation sites were recorded. There were no significant differences in the time taken for tumoral uptake to reach a plateau and that to reach minimum activity at the extravasation site among the three groups of mice. However, the mean tumoral activity and activity at the extravasation site were negatively correlated at 1 h post-injection. According to the clinical PET findings, the differences in SUV between the whole-body and regional images were not significantly correlated with the interval between injection of FDG and start of whole-body scanning, interval between the start of whole-body scanning and start of regional scanning, extravasation volume, maximum SUV of the extravasation site, or total activity at the extravasation site. The time taken for tumoral uptake to reach a plateau is not affected by extravasation, even at extensive degrees. Thus, in routine practice, the imaging time of approximately 60 min post-injection need not be modified even if extravasation is identified. However, tumor SUV may be underestimated in cases of extravasation.
Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE
NASA Astrophysics Data System (ADS)
Lamare, F.; Turzo, A.; Bizais, Y.; Cheze LeRest, C.; Visvikis, D.
2006-02-01
A newly developed simulation toolkit, GATE (Geant4 Application for Tomographic Emission), was used to develop a Monte Carlo simulation of a fully three-dimensional (3D) clinical PET scanner. The Philips Allegro/GEMINI PET systems were simulated in order to (a) allow a detailed study of the parameters affecting the system's performance under various imaging conditions, (b) study the optimization and quantitative accuracy of emission acquisition protocols for dynamic and static imaging, and (c) further validate the potential of GATE for the simulation of clinical PET systems. A model of the detection system and its geometry was developed. The accuracy of the developed detection model was tested through the comparison of simulated and measured results obtained with the Allegro/GEMINI systems for a number of NEMA NU2-2001 performance protocols including spatial resolution, sensitivity and scatter fraction. In addition, an approximate model of the system's dead time at the level of detected single events and coincidences was developed in an attempt to simulate the count rate related performance characteristics of the scanner. The developed dead-time model was assessed under different imaging conditions using the count rate loss and noise equivalent count rates performance protocols of standard and modified NEMA NU2-2001 (whole body imaging conditions) and NEMA NU2-1994 (brain imaging conditions) comparing simulated with experimental measurements obtained with the Allegro/GEMINI PET systems. Finally, a reconstructed image quality protocol was used to assess the overall performance of the developed model. An agreement of <3% was obtained in scatter fraction, with a difference between 4% and 10% in the true and random coincidence count rates respectively, throughout a range of activity concentrations and under various imaging conditions, resulting in <8% differences between simulated and measured noise equivalent count rates performance. Finally, the image quality validation study revealed a good agreement in signal-to-noise ratio and contrast recovery coefficients for a number of different volume spheres and two different (clinical level based) tumour-to-background ratios. In conclusion, these results support the accurate modelling of the Philips Allegro/GEMINI PET systems using GATE in combination with a dead-time model for the signal flow description, which leads to an agreement of <10% in coincidence count rates under different imaging conditions and clinically relevant activity concentration levels.
Liu, Xiaonan; Chen, Kewei; Wu, Teresa; Weidman, David; Lure, Fleming; Li, Jing
2018-04-01
Alzheimer's disease (AD) is a major neurodegenerative disease and the most common cause of dementia. Currently, no treatment exists to slow down or stop the progression of AD. There is converging belief that disease-modifying treatments should focus on early stages of the disease, that is, the mild cognitive impairment (MCI) and preclinical stages. Making a diagnosis of AD and offering a prognosis (likelihood of converting to AD) at these early stages are challenging tasks but possible with the help of multimodality imaging, such as magnetic resonance imaging (MRI), fluorodeoxyglucose (FDG)-positron emission topography (PET), amyloid-PET, and recently introduced tau-PET, which provides different but complementary information. This article is a focused review of existing research in the recent decade that used statistical machine learning and artificial intelligence methods to perform quantitative analysis of multimodality image data for diagnosis and prognosis of AD at the MCI or preclinical stages. We review the existing work in 3 subareas: diagnosis, prognosis, and methods for handling modality-wise missing data-a commonly encountered problem when using multimodality imaging for prediction or classification. Factors contributing to missing data include lack of imaging equipment, cost, difficulty of obtaining patient consent, and patient drop-off (in longitudinal studies). Finally, we summarize our major findings and provide some recommendations for potential future research directions. Copyright © 2018 Elsevier Inc. All rights reserved.
Morgan, Jenna L; Richards, Paul; Zaman, Osama; Ward, Sue; Collins, Karen; Robinson, Thompson; Cheung, Kwok-Leung; Audisio, Riccardo A; Reed, Malcolm W; Wyld, Lynda
2015-12-01
Up to 40% of women over 70 years with primary operable breast cancer in the UK are treated with primary endocrine therapy (PET) as an alternative to surgery. A variety of factors are important in determining treatment for older breast cancer patients. This study aimed to identify the patient and tumor factors associated with treatment allocation in this population. Prospectively collected data on treatment received (surgery vs. PET) were analysed with multivariable logistic regression using the variables age, modified Charlson Comorbidity Index (CCI), activities of daily living (ADL) score, Mini-Mental State Examination (MMSE) score, HER2 status, tumour size, grade and nodal status. Data were available for 1,122 cancers in 1,098 patients recruited between February 2013 and June 2015 from 51 UK hospitals. About 78% of the population were treated surgically, with the remainder being treated with PET. Increasing patient age at diagnosis, increasing CCI score, large tumor size (5 cm or more) and dependence in one or more ADL categories were all strongly associated with non-surgical treatment (P<0.05). Increasing comorbidity, large tumor size and reduced functional ability are associated with reduced likelihood of surgical treatment of breast cancer in older patients. However, age itself remains a significant factor for non-surgical treatment; reinforcing the need for evidence-based guidelines.
Doss, Mohan; Kolb, Hartmuth C; Walsh, Joseph C; Mocharla, Vani; Fan, Hong; Chaudhary, Ashok; Zhu, Zhihong; Alpaugh, R Katherine; Lango, Miriam N; Yu, Jian Q
2013-12-01
(18)F-CP-18, or (18S,21S,24S,27S,30S)-27-(2-carboxyethyl)-21-(carboxymethyl)-30-((2S,3R,4R,5R,6S)-6-((2-(4-(3-F18-fluoropropyl)-1H-1,2,3-triazol-1-yl)acetamido)methyl)-3,4,5-trihydroxytetrahydro-2H-pyran-2-carboxamido)-24-isopropyl-18-methyl-17,20,23,26,29-pentaoxo-4,7,10,13-tetraoxa-16,19,22,25,28-pentaazadotriacontane-1,32-dioic acid, is being evaluated as a tissue apoptosis marker for PET imaging. The purpose of this study was to determine the biodistribution and estimate the normal-organ radiation-absorbed doses and effective dose from (18)F-CP-18. Successive whole-body PET/CT scans were obtained at approximately 7, 45, 90, 130, and 170 min after intravenous injection of (18)F-CP-18 in 7 healthy human volunteers. Blood samples and urine were collected between the PET/CT scans, and the biostability of (18)F-CP-18 was assessed using high-performance liquid chromatography. The PET scans were analyzed to determine the radiotracer uptake in different organs. OLINDA/EXM software was used to calculate human radiation doses based on the biodistribution of the tracer. (18)F-CP-18 was 54% intact in human blood at 135 min after injection. The tracer cleared rapidly from the blood pool with a half-life of approximately 30 min. Relatively high (18)F-CP-18 uptake was observed in the kidneys and bladder, with diffuse uptake in the liver and heart. The mean standardized uptake values (SUVs) in the bladder, kidneys, heart, and liver at around 50 min after injection were approximately 65, 6, 1.5, and 1.5, respectively. The calculated effective dose was 38 ± 4 μSv/MBq, with the urinary bladder wall having the highest absorbed dose at 536 ± 61 μGy/MBq using a 4.8-h bladder-voiding interval for the male phantom. For a 1-h voiding interval, these doses were reduced to 15 ± 2 μSv/MBq and 142 ± 15 μGy/MBq, respectively. For a typical injected activity of 555 MBq, the effective dose would be 21.1 ± 2.2 mSv for the 4.8-h interval, reduced to 8.3 ± 1.1 mSv for the 1-h interval. (18)F-CP-18 cleared rapidly through the renal system. The urinary bladder wall received the highest radiation dose and was deemed the critical organ. Both the effective dose and the bladder dose can be reduced by frequent voiding. From the radiation dosimetry perspective, the apoptosis imaging agent (18)F-CP-18 is suitable for human use.
Murray, Louis C.
2009-01-01
Water-use data collected between 1992 and 2006 at eight municipal water-supply utilities in east-central and northeast Florida were analyzed to identify seasonal trends in use and to quantify monthly variations. Regression analyses were applied to identify significant correlations between water use and selected meteorological parameters and drought indices. Selected parameters and indices include precipitation (P), air temperature (T), potential evapotranspiration (PET), available water (P-PET), monthly changes in these parameters (Delta P, Delta T, Delta PET, Delta(P-PET), the Palmer Drought Severity Index (PDSI), and the Standardized Precipitation Index (SPI). Selected utilities include the City of Daytona Beach (Daytona), the City of Eustis (Eustis), Gainesville Regional Utilities (GRU), Jacksonville Electric Authority (JEA), Orange County Utilities (OCU), Orlando Utilities Commission (OUC), Seminole County Utilities (SCU), and the City of St. Augustine (St. Augustine). Water-use rates at these utilities in 2006 ranged from about 3.2 million gallons per day at Eustis to about 131 million gallons per day at JEA. Total water-use rates increased at all utilities throughout the 15-year period of record, ranging from about 4 percent at Daytona to greater than 200 percent at OCU and SCU. Metered rates, however, decreased at six of the eight utilities, ranging from about 2 percent at OCU and OUC to about 17 percent at Eustis. Decreases in metered rates occurred because the number of metered connections increased at a greater rate than did total water use, suggesting that factors other than just population growth may play important roles in water-use dynamics. Given the absence of a concurrent trend in precipitation, these decreases can likely be attributed to changes in non-climatic factors such as water-use type, usage of reclaimed water, water-use restrictions, demographics, and so forth. When averaged for the eight utilities, metered water-use rates depict a clear seasonal pattern in which rates were lowest in the winter and greatest in the late spring. Averaged water-use rates ranged from about 9 percent below the 15-year daily mean in January to about 11 percent above the daily mean in May. Water-use rates were found to be statistically correlated to meteorological parameters and drought indices, and to be influenced by system memory. Metered rates (in gallons per day per active metered connection) were consistently found to be influenced by P, T, PET, and P-PET and changes in these parameters that occurred in prior months. In the single-variant analyses, best correlations were obtained by fitting polynomial functions to plots of metered rates versus moving-averaged values of selected parameters (R2 values greater than 0.50 at three of eight sites). Overall, metered water-use rates were best correlated with the 3- to 4-month moving average of Delta T or Delta PET (R2 values up to 0.66), whereas the full suite of meteorological parameters was best correlated with metered rates at Daytona and least correlated with rates at St. Augustine. Similarly, metered rates were substantially better correlated with moving-averaged values of precipitation (significant at all eight sites) than with single (current) monthly values (significant at only three sites). Total and metered water-use rates were positively correlated with T, PET, Delta P, Delta T, and Delta PET, and negatively correlated with P, P-PET, Delta (P-PET), PDSI, and SPI. The drought indices were better correlated with total water-use rates than with metered rates, whereas metered rates were better correlated with meteorological parameters. Multivariant analyses produced fits of the data that explained a greater degree of the variance in metered rates than did the single-variant analyses. Adjusted R2 values for the 'best' models ranged from 0.79 at JEA to 0.29 at St. Augustine and exceeded 0.60 at five of eight sites. The amount of available water (P-PET) was the si
Liang, Winnie S.; Chen, Kewei; Lee, Wendy; Sidhar, Kunal; Corneveaux, Jason J.; Allen, April N.; Myers, Amanda; Villa, Stephen; Meechoovet, Bessie; Pruzin, Jeremy; Bandy, Daniel; Fleisher, Adam S.; Langbaum, Jessica B.S.; Huentelman, Matthew J.; Jensen, Kendall; Dunckley, Travis; Caselli, Richard J.; Kaib, Susan; Reiman, Eric M.
2010-01-01
In a genome-wide association study (GWAS) of late-onset Alzheimer's disease (AD), we found an association between common haplotypes of the GAB2 gene and AD risk in carriers of the apolipoprotein E (APOE) ε4 allele, the major late-onset AD susceptibility gene. We previously proposed the use of fluorodeoxyglucose positron emission tomography (FDG-PET) measurements as a quantitative presymptomatic endophenotype, more closely related to disease risk than the clinical syndrome itself, to help evaluate putative genetic and non-genetic modifiers of AD risk. In this study, we examined the relationship between the presence or absence of the relatively protective GAB2 haplotype and PET measurements of regional-to-whole brain FDG uptake in several AD-affected brain regions in 158 cognitively normal late-middle-aged APOEε4 homozygotes, heterozygotes, and non-carriers. GAB2 haplotypes were characterized using Affymetrix Genome-Wide Human SNP 6.0 Array data from each of these subjects. As predicted, the possibly protective GAB2 haplotype was associated with higher regional-to-whole brain FDG uptake in AD-affected brain regions in APOEε4 carriers. While additional studies are needed, this study supports the association between the possibly protective GAB2 haplotype and the risk of late-onset AD in APOEε4 carriers. It also supports the use of brain-imaging endophenotypes to help assess possible modifiers of AD risk. PMID:20888920
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-29
... those positions. Under Eurex customer clearing, the clearing relationship and Eurex's guarantee extends... member default. The customer relationship would be governed by an agreement between the customer and the...' customers (in addition to clearing CDS transactions of members and their affiliates, as permitted by the...
Selected PET radiomic features remain the same.
Tsujikawa, Tetsuya; Tsuyoshi, Hideaki; Kanno, Masafumi; Yamada, Shizuka; Kobayashi, Masato; Narita, Norihiko; Kimura, Hirohiko; Fujieda, Shigeharu; Yoshida, Yoshio; Okazawa, Hidehiko
2018-04-17
We investigated whether PET radiomic features are affected by differences in the scanner, scan protocol, and lesion location using 18 F-FDG PET/CT and PET/MR scans. SUV, TMR, skewness, kurtosis, entropy, and homogeneity strongly correlated between PET/CT and PET/MR images. SUVs were significantly higher on PET/MR 0-2 min and PET/MR 0-10 min than on PET/CT in gynecological cancer ( p = 0.008 and 0.008, respectively), whereas no significant difference was observed between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images in oral cavity/oropharyngeal cancer. TMRs on PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min increased in this order in gynecological cancer and oral cavity/oropharyngeal cancer. In contrast to conventional and histogram indices, 4 textural features (entropy, homogeneity, SRE, and LRE) were not significantly different between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images. 18 F-FDG PET radiomic features strongly correlated between PET/CT and PET/MR images. Dixon-based attenuation correction on PET/MR images underestimated tumor tracer uptake more significantly in oral cavity/oropharyngeal cancer than in gynecological cancer. 18 F-FDG PET textural features were affected less by differences in the scanner and scan protocol than conventional and histogram features, possibly due to the resampling process using a medium bin width. Eight patients with gynecological cancer and 7 with oral cavity/oropharyngeal cancer underwent a whole-body 18 F-FDG PET/CT scan and regional PET/MR scan in one day. PET/MR scans were performed for 10 minutes in the list mode, and PET/CT and 0-2 min and 0-10 min PET/MR images were reconstructed. The standardized uptake value (SUV), tumor-to-muscle SUV ratio (TMR), skewness, kurtosis, entropy, homogeneity, short-run emphasis (SRE), and long-run emphasis (LRE) were compared between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images.
Yao, Rutao; Ramachandra, Ranjith M.; Mahajan, Neeraj; Rathod, Vinay; Gunasekar, Noel; Panse, Ashish; Ma, Tianyu; Jian, Yiqiang; Yan, Jianhua; Carson, Richard E.
2012-01-01
To achieve optimal PET image reconstruction through better system modeling, we developed a system matrix that is based on the probability density function for each line of response (LOR-PDF). The LOR-PDFs are grouped by LOR-to-detector incident angles to form a highly compact system matrix. The system matrix was implemented in the MOLAR list mode reconstruction algorithm for a small animal PET scanner. The impact of LOR-PDF on reconstructed image quality was assessed qualitatively as well as quantitatively in terms of contrast recovery coefficient (CRC) and coefficient of variance (COV), and its performance was compared with a fixed Gaussian (iso-Gaussian) line spread function. The LOR-PDFs of 3 coincidence signal emitting sources, 1) ideal positron emitter that emits perfect back-to-back γ rays (γγ) in air; 2) fluorine-18 (18F) nuclide in water; and 3) oxygen-15 (15O) nuclide in water, were derived, and assessed with simulated and experimental phantom data. The derived LOR-PDFs showed anisotropic and asymmetric characteristics dependent on LOR-detector angle, coincidence emitting source, and the medium, consistent with common PET physical principles. The comparison of the iso-Gaussian function and LOR-PDF showed that: 1) without positron range and acolinearity effects, the LOR-PDF achieved better or similar trade-offs of contrast recovery and noise for objects of 4-mm radius or larger, and this advantage extended to smaller objects (e.g. 2-mm radius sphere, 0.6-mm radius hot-rods) at higher iteration numbers; and 2) with positron range and acolinearity effects, the iso-Gaussian achieved similar or better resolution recovery depending on the significance of positron range effect. We conclude that the 3-D LOR-PDF approach is an effective method to generate an accurate and compact system matrix. However, when used directly in expectation-maximization based list-mode iterative reconstruction algorithms such as MOLAR, its superiority is not clear. For this application, using an iso-Gaussian function in MOLAR is a simple but effective technique for PET reconstruction. PMID:23032702
Wang, Qiang; Wen, Jie; Ravindranath, Bosky; O’Sullivan, Andrew W.; Catherall, David; Li, Ke; Wei, Shouyi; Komarov, Sergey; Tai, Yuan-Chuan
2015-01-01
Compact high-resolution panel detectors using virtual pinhole (VP) PET geometry can be inserted into existing clinical or pre-clinical PET systems to improve regional spatial resolution and sensitivity. Here we describe a compact panel PET detector built using the new Though Silicon Via (TSV) multi-pixel photon counters (MPPC) detector. This insert provides high spatial resolution and good timing performance for multiple bio-medical applications. Because the TSV MPPC design eliminates wire bonding and has a package dimension which is very close to the MPPC’s active area, it is 4-side buttable. The custom designed MPPC array (based on Hamamatsu S12641-PA-50(x)) used in the prototype is composed of 4 × 4 TSV-MPPC cells with a 4.46 mm pitch in both directions. The detector module has 16 × 16 lutetium yttrium oxyorthosilicate (LYSO) crystal array, with each crystal measuring 0.92 × 0.92 × 3 mm3 with 1.0 mm pitch. The outer diameter of the detector block is 16.8 × 16.8 mm2. Thirty-two such blocks will be arranged in a 4 × 8 array with 1 mm gaps to form a panel detector with detection area around 7 cm × 14 cm in the full-size detector. The flood histogram acquired with Ge-68 source showed excellent crystal separation capability with all 256 crystals clearly resolved. The detector module’s mean, standard deviation, minimum (best) and maximum (worst) energy resolution were 10.19%, +/−0.68%, 8.36% and 13.45% FWHM, respectively. The measured coincidence time resolution between the block detector and a fast reference detector (around 200 ps single photon timing resolution) was 0.95 ns. When tested with Siemens Cardinal electronics the performance of the detector blocks remain consistent. These results demonstrate that the TSV-MPPC is a promising photon sensor for use in a flat panel PET insert composed of many high resolution compact detector modules. PMID:26085702
Breer, Stefan; Brunkhorst, Thomas; Beil, F Timo; Peldschus, Kersten; Heiland, Max; Klutmann, Susanne; Barvencik, Florian; Zustin, Jozef; Gratz, Klaus-Friedrich; Amling, Michael
2014-07-01
Tumor-induced osteomalacia (TIO) is a paraneoplastic syndrome characterized by renal phosphate wasting, hypophosphatemia and low calcitriol levels as well as clinical symptoms like diffuse bone and muscle pain, fatigue fractures or increased fracture risk. Conventional imaging methods, however, often fail to detect the small tumors. Lately, tumor localization clearly improved by somatostatin-receptor (SSTR) imaging, such as octreotide scintigraphy or octreotide SPECT/CT. However, recent studies revealed that still a large number of tumors remained undetected by octreotide imaging. Hence, studies focused on different SSTR imaging methods such as 68Ga DOTA-NOC, 68Ga DOTA-TOC and 68Ga DOTA-TATE PET/CT with promising first results. Studies comparing different SSTR imaging methods for tumor localization in TIO are rare and thus little is known about diagnostic alternatives once a particular method failed to detect a tumor in patients with TIO. Here, we report the data of 5 consecutive patients suffering from TIO, who underwent both 111Indium-octreotide scintigraphy (111In-OCT) SPECT/CT as well as 68Ga DOTA-TATE PET/CT for tumor detection. While 111In-OCT SPECT/CT allowed tumor detection in only 1 of 5 patients, 68Ga DOTA-TATE PET/CT was able to localize the tumor in all patients. Afterwards, anatomical imaging of the region of interest was performed with CT and MRI. Thus, successful surgical resection of the tumor was achieved in all patients. Serum phosphate levels returned to normal and all patients reported relief of symptoms within weeks. Moreover, an iliac crest biopsy was obtained from every patient and revealed marked osteomalacia in all cases. Follow-up DXA revealed an increase in BMD of up to 34.5% 1-year postoperative, indicating remineralization. No recurrence was observed. In conclusion our data indicates that 68Ga DOTA-TATE PET/CT is an effective and promising diagnostic tool in the diagnosis of TIO, even in patients in whom 111In-OCT prior failed to detect a tumor. Copyright © 2014 Elsevier Inc. All rights reserved.
[18F]FP-(+)-DTBZ PET study in a lactacystin-treated rat model of Parkinson disease.
Weng, Chi-Chang; Huang, Siao-Lan; Chen, Zi-An; Lin, Kun-Ju; Hsiao, Ing-Tsung; Yen, Tzu-Chen; Kung, Mei-Ping; Wey, Shiaw-Pyng; Hsu, Ching-Han
2017-08-01
Lactacystin has been used to establish rodent models of Parkinson disease (PD), with cerebral α-synuclein inclusions. This study evaluated the uptake of [ 18 F]9-fluoropropyl-(+)-dihydrotetrabenazine ([ 18 F]FP-(+)-DTBZ), a vesicular monoamine transporter type 2 (VMAT2)-targeting radiotracer, through positron emission tomography (PET) in lactacystin-treated rat brains. Adult male Sprague-Dawley rats were randomly treated with a single intracranial dose of lactacystin (2 or 5 μg) or saline (served as the sham control) into the left medial forebrain bundle. A 30-min static [ 18 F]FP-(+)-DTBZ brain PET scan was performed following an intravenous [ 18 F]FP-(+)-DTBZ dose (approximately 22 MBq) in each animal at 2 and 3 weeks after lactacystin treatment. Upon completing the last PET scans, the animals were killed, and their brains were dissected for ex vivo autoradiography (ARG) and immunohistochemical (IHC) staining of tyrosine hydroxylase (TH) as well as VMAT2. Both the 2- and 5-μg lactacystin-treated groups exhibited significantly decreased specific [ 18 F]FP-(+)-DTBZ uptake in the ipsilateral striata (I-ST) at 2 weeks (1.51 and 1.16, respectively) and 3 weeks (1.36 and 1.00, respectively) after lactacystin treatment, compared with the uptake in the corresponding contralateral striata (C-ST) (3.48 and 3.08 for the 2- and 5-μg lactacystin-treated groups, respectively, at 2 weeks; 3.36 and 3.11 for the 2- and 5-μg lactacystin-treated groups, respectively, at 3 weeks) and the sham controls (3.34-3.53). Lactacystin-induced decline in I-ST [ 18 F]FP-(+)-DTBZ uptake was also demonstrated through ex vivo ARG, and the corresponding dopaminergic neuron damage was confirmed by the results of TH- and VMAT2-IHC studies. In this PD model, lactacystin-induced dopaminergic terminal damage in the ipsilateral striatum could be clearly visualized through in vivo [ 18 F]FP-(+)-DTBZ PET imaging. This may serve as a useful approach for evaluating the effectiveness of new treatments for PD.
PET Imaging of Abdominal Aortic Aneurysm with 64Cu-Labeled Anti-CD105 Antibody Fab Fragment.
Shi, Sixiang; Orbay, Hakan; Yang, Yunan; Graves, Stephen A; Nayak, Tapas R; Hong, Hao; Hernandez, Reinier; Luo, Haiming; Goel, Shreya; Theuer, Charles P; Nickles, Robert J; Cai, Weibo
2015-06-01
The critical challenge in abdominal aortic aneurysm (AAA) research is the accurate diagnosis and assessment of AAA progression. Angiogenesis is a pathologic hallmark of AAA, and CD105 is highly expressed on newly formed vessels. Our goal was to use (64)Cu-labeled anti-CD105 antibody Fab fragment for noninvasive assessment of angiogenesis in the aortic wall in a murine model of AAA. Fab fragment of TRC105, a mAb that specifically binds to CD105, was generated by enzymatic papain digestion and conjugated to NOTA (1,4,7-triazacyclononane-1,4,7-triacetic acid) for (64)Cu labeling. The binding affinity/specificity of NOTA-TRC105-Fab was evaluated by flow cytometry and various ex vivo studies. BALB/c mice were anesthetized and treated with calcium phosphate to induce AAA and underwent weekly PET scans using (64)Cu-NOTA-TRC105-Fab. Biodistribution and autoradiography studies were also performed to confirm the accuracy of PET results. NOTA-TRC105-Fab exhibited high purity and specifically bound to CD105 in vitro. Uptake of (64)Cu-NOTA-TRC105-Fab increased from a control level of 3.4 ± 0.1 to 9.5 ± 0.4 percentage injected dose per gram (%ID/g) at 6 h after injection on day 5 and decreased to 7.2 ± 1.4 %ID/g on day 12, which correlated well with biodistribution and autoradiography studies (i.e., much higher tracer uptake in AAA than normal aorta). Of note, enhanced AAA contrast was achieved, due to the minimal background in the abdominal area of mice. Degradation of elastic fibers and highly expressed CD105 were observed in ex vivo studies. (64)Cu-NOTA-TRC105-Fab cleared rapidly through the kidneys, which enabled noninvasive PET imaging of the aorta with enhanced contrast and showed increased angiogenesis (CD105 expression) during AAA. (64)Cu-NOTA-TRC105-Fab PET may potentially be used for future diagnosis and prognosis of AAA. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Lam, Karen; Chan, Conrad; Reilly, Raymond M.
2017-01-01
ABSTRACT We previously reported that microSPECT/CT imaging with 111In-labeled pertuzumab detected decreased HER2 expression in human breast cancer (BC) xenografts in athymic mice associated with response to treatment with trastuzumab (Herceptin). Our aim was to extend these results to PET/CT by constructing F(ab′)2 of pertuzumab modified with NOTA chelators for complexing 64Cu. The effect of the administered mass (5–200 µg) of 64Cu-NOTA-pertuzumab F(ab′)2 was studied in NOD/SCID mice engrafted with HER2-positive SK-OV-3 human ovarian cancer xenografts. Biodistribution studies were performed in non-tumor bearing Balb/c mice to predict radiation doses to normal organs in humans. Serial PET/CT imaging was conducted on mice engrafted with HER2-positive and trastuzumab-sensitive BT-474 or trastuzumab-insensitive SK-OV-3 xenografted mice treated with weekly doses of trastuzumab. There were no significant effects of the administered mass of 64Cu-NOTA-pertuzumab F(ab′)2 on tumor or normal tissue uptake. The predicted total body dose in humans was 0.015 mSv/MBq, a 3.3-fold reduction compared to 111In-labeled pertuzumab. MicroPET/CT images revealed specific tumor uptake of 64Cu-NOTA-pertuzumab F(ab′)2 at 24 or 48 h post-injection in mice with SK-OV-3 tumors. Image analysis of mice treated with trastuzumab showed 2-fold reduced uptake of 64Cu-NOTA-pertuzumab F(ab′)2 in BT-474 tumors after 1 week of trastuzumab normalized to baseline, and 1.9-fold increased uptake in SK-OV-3 tumors after 3 weeks of trastuzumab, consistent with tumor response and resistance, respectively. We conclude that PET/CT imaging with 64Cu-NOTA-pertuzumab F(ab′)2 detected changes in HER2 expression in response to trastuzumab while delivering a lower total body radiation dose compared to 111In-labeled pertuzumab. PMID:27813707
Blanc-Durand, Paul; Van Der Gucht, Axel; Schaefer, Niklaus; Itti, Emmanuel; Prior, John O
2018-01-01
Amino-acids positron emission tomography (PET) is increasingly used in the diagnostic workup of patients with gliomas, including differential diagnosis, evaluation of tumor extension, treatment planning and follow-up. Recently, progresses of computer vision and machine learning have been translated for medical imaging. Aim was to demonstrate the feasibility of an automated 18F-fluoro-ethyl-tyrosine (18F-FET) PET lesion detection and segmentation relying on a full 3D U-Net Convolutional Neural Network (CNN). All dynamic 18F-FET PET brain image volumes were temporally realigned to the first dynamic acquisition, coregistered and spatially normalized onto the Montreal Neurological Institute template. Ground truth segmentations were obtained using manual delineation and thresholding (1.3 x background). The volumetric CNN was implemented based on a modified Keras implementation of a U-Net library with 3 layers for the encoding and decoding paths. Dice similarity coefficient (DSC) was used as an accuracy measure of segmentation. Thirty-seven patients were included (26 [70%] in the training set and 11 [30%] in the validation set). All 11 lesions were accurately detected with no false positive, resulting in a sensitivity and a specificity for the detection at the tumor level of 100%. After 150 epochs, DSC reached 0.7924 in the training set and 0.7911 in the validation set. After morphological dilatation and fixed thresholding of the predicted U-Net mask a substantial improvement of the DSC to 0.8231 (+ 4.1%) was noted. At the voxel level, this segmentation led to a 0.88 sensitivity [95% CI, 87.1 to, 88.2%] a 0.99 specificity [99.9 to 99.9%], a 0.78 positive predictive value: [76.9 to 78.3%], and a 0.99 negative predictive value [99.9 to 99.9%]. With relatively high performance, it was proposed the first full 3D automated procedure for segmentation of 18F-FET PET brain images of patients with different gliomas using a U-Net CNN architecture.
Comparison of 18F-FDG PET/CT and PET/MRI in patients with multiple myeloma
Sachpekidis, Christos; Hillengass, Jens; Goldschmidt, Hartmut; Mosebach, Jennifer; Pan, Leyun; Schlemmer, Heinz-Peter; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia
2015-01-01
PET/MRI represents a promising hybrid imaging modality with several potential clinical applications. Although PET/MRI seems highly attractive in the diagnostic approach of multiple myeloma (MM), its role has not yet been evaluated. The aims of this prospective study are to evaluate the feasibility of 18F-FDG PET/MRI in detection of MM lesions, and to investigate the reproducibility of bone marrow lesions detection and quantitative data of 18F-FDG uptake between the functional (PET) component of PET/CT and PET/MRI in MM patients. The study includes 30 MM patients. All patients initially underwent 18F-FDG PET/CT (60 min p.i.), followed by PET/MRI (120 min p.i.). PET/CT and PET/MRI data were assessed and compared based on qualitative (lesion detection) and quantitative (SUV) evaluation. The hybrid PET/MRI system provided good image quality in all cases without artefacts. PET/MRI identified 65 of the 69 lesions, which were detectable with PET/CT (94.2%). Quantitative PET evaluations showed the following mean values in MM lesions: SUVaverage=5.5 and SUVmax=7.9 for PET/CT; SUVaverage=3.9 and SUVmax=5.8 for PET/MRI. Both SUVaverage and SUVmax were significantly higher on PET/CT than on PET/MRI. Spearman correlation analysis demonstrated a strong correlation between both lesional SUVaverage (r=0.744) and lesional SUVmax (r=0.855) values derived from PET/CT and PET/MRI. Regarding detection of myeloma skeletal lesions, PET/MRI exhibited equivalent performance to PET/CT. In terms of tracer uptake quantitation, a significant correlation between the two techniques was demonstrated, despite the statistically significant differences in lesional SUVs between PET/CT and PET/MRI. PMID:26550538
Wiesmüller, Marco; Quick, Harald H; Navalpakkam, Bharath; Lell, Michael M; Uder, Michael; Ritt, Philipp; Schmidt, Daniela; Beck, Michael; Kuwert, Torsten; von Gall, Carl C
2013-01-01
PET/MR hybrid scanners have recently been introduced, but not yet validated. The aim of this study was to compare the PET components of a PET/CT hybrid system and of a simultaneous whole-body PET/MR hybrid system with regard to reproducibility of lesion detection and quantitation of tracer uptake. A total of 46 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 88 min later a second scan using a hybrid PET/MR system. The radioactive tracers used were (18)F-deoxyglucose (FDG), (18)F-ethylcholine (FEC) and (68)Ga-DOTATATE (Ga-DOTATATE). The PET images from PET/CT (PET(CT)) and from PET/MR (PET(MR)) were analysed for tracer-positive lesions. Regional tracer uptake in these foci was quantified using volumes of interest, and maximal and average standardized uptake values (SUV(max) and SUV(avg), respectively) were calculated. Of the 46 patients, 43 were eligible for comparison and statistical analysis. All lesions except one identified by PET(CT) were identified by PET(MR) (99.2 %). In 38 patients (88.4 %), the same number of foci were identified by PET(CT) and by PET(MR). In four patients, more lesions were identified by PET(MR) than by PET(CT), in one patient PET(CT) revealed an additional focus compared to PET(MR). The mean SUV(max) and SUV(avg) of all lesions determined by PET(MR) were by 21 % and 11 % lower, respectively, than the values determined by PET(CT) (p < 0.05), and a strong correlation between these variables was identified (Spearman rho 0.835; p < 0.01). PET/MR showed equivalent performance in terms of qualitative lesion detection to PET/CT. The differences demonstrated in quantitation of tracer uptake between PET(CT) and PET(MR) were minor, but statistically significant. Nevertheless, a more detailed study of the quantitative accuracy of PET(MR) and the factors governing it is needed to ultimately assess its accuracy in measuring tissue tracer concentrations.
Pinilla, I; Gómez-León, N; Del Campo-Del Val, L; Hernandez-Maraver, D; Rodríguez-Vigil, B; Jover-Díaz, R; Coya, J
2011-10-01
The aim of this paper was to compare the accuracy of contrast-enhanced computed tomography (CT), positron emission tomography (PET), unenhanced low-dose PET/CT (LD-PET/CT) and full-dose enhanced PET/CT (FD-PET/CT) for the initial staging of lymphoma. One hundred and one lymphoma patients were examined by [18F]FDG-PET/CT including unenhanced low-dose CT and enhanced full-dose CT. Each modality of PET/CT was evaluated by a nuclear medicine physician and a radiologist unaware of the other modality, while the CT and PET images were interpreted separately by another independent radiologist and nuclear medicine physician respectively. The nodal and extranodal lesions detected by each technique were compared with a reference standard. For nodal assessment, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative LR (LR-) of LD-PET/CT were 97%, 96%, 98%, 95%, 26 and 0.02 respectively, and those of FD-PET/CT were 97%, 97%, 98%, 95%, 36 and 0.02. These results were significantly better than those of PET (sensitivity 82%, specificity 81%, PPV 88%, NPV 72%, LR+ 4.3, LR- 0.21). Likewise, both PET/CT displayed a higher sensitivity, NPV and LR- than CT (91%, 84%, 0.1 respectively). For organ evaluation, both modalities of PET/CT also had significantly better sensitivity and NPV than that of PET (LD-PET/CT: sensitivity 92%, NPV 90%; FD-PET/CT sensitivity 94%, NPV 92%; PET: sensitivity 70%, NPV 69%). The sensitivity, specificity, PPV and NPV for bone marrow involvement were 29%, 84%, 45% and 72% respectively for PET, and 29%, 90%, 56%, and 74% for both, LD-PET/CT, and FD-PET/CT. No significant differences were found between LD-PET/CT and FD-PET/CT, but FD-PET/CT detected important incidental findings in 5.9% of patients. PET/CT is an accurate technique for the initial staging of lymphomas without significant differences between LD-PET/CT and FD-PET/CT. FD-PET/CT detects relevant incidental findings that are missed on LD-PET/CT.
The role of the early-life environment in the development of allergic disease.
Wegienka, Ganesa; Zoratti, Edward; Johnson, Christine Cole
2015-02-01
A consensus has been reached that the development of allergic disorders is strongly influenced by early life exposures. An overview of several prenatal and early life factors that have been investigated for their associations with development of childhood allergy is presented. Delivery mode, the gut microbiome, vitamin D, folate, breastfeeding, pets, antibiotics, environmental tobacco smoke, and airborne traffic pollutants are discussed. Although many studies suggest an effect, overall, no risk factors clearly increase or reduce the risk of allergic outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.
The Petit Rat (pet/pet), a New Semilethal Mutant Dwarf Rat with Thymic and Testicular Anomalies
Chiba, Junko; Suzuki, Katsushi; Suzuki, Hiroetsu
2008-01-01
The petit rat (pet/pet) is a recently discovered semilethal mutant dwarf. The neonatal pet/pet rats had a low body weight and small thymus and testis. During the first 3 d after birth, 50% of the male and 80% of the female pet/pet pups were lost or found dead. Surviving pet/pet rats showed marked retardation of postnatal growth, and their body weights were 41% (female rats) and 32% (male rats) of those of normal rats at the adult stage. The pet/pet rats exhibited proportional dwarfism, and their longitudinal bones were shorter than those of controls without skeletal malformations. Most organs of male pet/pet rats, especially the thymus, testis, adipose tissue surrounding the kidney, and accessory sex organs, weighed markedly less at 140 d of age than did those of their normal counterparts. The thymus of pet/pet rats was small with abnormal thymic follicles. Testes from pet/pet rats exhibited 2 patterns of abnormal histology. Spermatogenesis was present in testes that were only slightly anomalous, but the seminiferous tubules were reduced in diameter. In severely affected testes, most of the seminiferous tubules showed degeneration, and interstitial tissue was increased. Plasma growth hormone concentrations did not differ between pet/pet and normal male rats. The dwarf phenotype of pet/pet rats was inherited as an autosomal recessive trait. These results indicate that the pet/pet rat has a semilethal growth-hormone-independent dwarf phenotype that is accompanied by thymic and testicular anomalies and low birth weight. PMID:19149412
Downes, Martin J; Devitt, Catherine; Downes, Marie T; More, Simon J
2017-01-01
Pet cat and dog obesity contributes to increased risk of several diseases, including cancer and diabetes mellitus as well as a worsening of orthopaedic problems, and a reduction in survival rate. This study aims to develop a better understanding of cat and dog owners' self-reported beliefs and factors that influence owner behaviour around feeding and exercising their pet cat or dog, as there is a lack of in-depth understanding in this area. Seven focus group discussions, with 43 pet owners in total, were conducted. Pet owners often reported a perceived a low level of control over feeding; often undermined by other people feeding of their pet, their pets begging for food, and their pets attitude towards food. Treats were used in the absence of owner control over pet begging and emotional attachment, and to influence pet behaviour. The majority of participants had positive attitudes to pet exercise, which could be related to pet specific requirements, especially differences in cats and dogs. There were some negative experiences of stress associated with dog walking and fears over aggressive confrontations with other dogs. Feeding one's pet is influenced by beliefs about pet specific needs, pet food and pet health, pet owners' perceived control over feeding, and the implications for the pet owner. Pet exercise is influenced by beliefs about pet specific exercise needs, and the implications of exercising one's pet for the pet owner. Understanding owner behaviours on feeding and exercise allows for a more targeted approach to preventing and treating pet obesity.
Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.
Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim
2018-02-01
The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.
The petit rat (pet/pet), a new semilethal mutant dwarf rat with thymic and testicular anomalies.
Chiba, Junko; Suzuki, Katsushi; Suzuki, Hiroetsu
2008-12-01
The petit rat (pet/pet) is a recently discovered semilethal mutant dwarf. The neonatal pet/pet rats had a low body weight and small thymus and testis. During the first 3 d after birth, 50% of the male and 80% of the female pet/pet pups were lost or found dead. Surviving pet/pet rats showed marked retardation of postnatal growth, and their body weights were 41% (female rats) and 32% (male rats) of those of normal rats at the adult stage. The pet/pet rats exhibited proportional dwarfism, and their longitudinal bones were shorter than those of controls without skeletal malformations. Most organs of male pet/pet rats, especially the thymus, testis, adipose tissue surrounding the kidney, and accessory sex organs, weighed markedly less at 140 d of age than did those of their normal counterparts. The thymus of pet/pet rats was small with abnormal thymic follicles. Testes from pet/pet rats exhibited 2 patterns of abnormal histology. Spermatogenesis was present in testes that were only slightly anomalous, but the seminiferous tubules were reduced in diameter. In severely affected testes, most of the seminiferous tubules showed degeneration, and interstitial tissue was increased. Plasma growth hormone concentrations did not differ between pet/pet and normal male rats. The dwarf phenotype of pet/pet rats was inherited as an autosomal recessive trait. These results indicate that the pet/pet rat has a semilethal growth-hormone-independent dwarf phenotype that is accompanied by thymic and testicular anomalies and low birth weight.
Pet Problems at Home: Pet Problems in the Community.
ERIC Educational Resources Information Center
Soltow, Willow
1984-01-01
Discusses problems of pets in the community, examining the community's role related to disruptive pets and pet overpopulation. Also discusses pet problems at home, offering advice on selecting a pet, meeting a pet's needs, and disciplining pets. Includes a list of books, films/filmstrips, teaching materials, and various instructional strategies.…
Lee, Soo Jin; Paeng, Jin Chul; Goo, Jin Mo; Lee, Jeong Min; Cheon, Gi Jeong; Lee, Dong Soo; Chung, June-Key; Kang, Keon Wook
2017-04-01
The purpose of this study was to compare quantitative indexes for fluorine-18 fluorodeoxyglucose uptake and metabolic volume between PET/MRI and PET/CT. Sixty-six patients with solid tumors (32 with lung cancer and 34 with pancreatic cancer) who underwent sequential fluorine-18 fluorodeoxyglucose PET/MRI and PET/CT were retrospectively enrolled. On PET images, maximum and peak standardized uptake values (SUVmax and SUVpeak, respectively), and maximum tumor-to-liver ratio (TLRmax) were measured. Metabolic tumor volume (MTV) and total-lesion glycolysis (TLG) with margin thresholds of 50% SUVmax and SUV 2.5 (MTV50%, MTV2.5; TLG50%, TLG2.5, respectively) were compared between PET/MRI and PET/CT, with patients classified into two groups using imaging protocol (the PET/MRI-first and PET/CT-first groups). There were significant correlations of all tested indexes between PET/MRI and PET/CT (r=0.867-0.987, P<0.001). SUVmax and SUVpeak were lower on PET/MRI regardless of imaging protocol (P<0.001 in the PET/MRI-first group). In contrast, TLRmax exhibited reverse results between the PET/MRI-first and PET/CT-first groups. MTV50% and TLG values varied between PET/MRI and PET/CT, as well as between the PET/MRI-first and PET/CT-first groups. However, MTV2.5 was relatively robust against imaging protocol and modality. There are significant correlations of the quantitative indexes between PET/MRI and PET/CT. However, uptake indexes of SUVmax and SUVpeak are lower on PET/MRI than on PET/CT, and volumetric indexes of MTV50% and TLG values also exhibited significant differences. It may be suggested that TLRmax and MTV2.5 are relatively more appropriate indexes than others when PET/MRI and PET/CT are used interchangeably.
... PET - chest; PET - lung; PET - tumor imaging; PET/CT - lung; Solitary pulmonary nodule - PET ... minutes. PET scans are performed along with a CT scan. This is because the combined information from ...
Positron Emission Tomography (PET)
DOE R&D Accomplishments Database
Welch, M. J.
1990-01-01
Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.
Xia, Chenjie; Makaretz, Sara J.; Caso, Christina; McGinnis, Scott; Gomperts, Stephen N.; Sepulcre, Jorge; Gomez-Isla, Teresa; Hyman, Bradley T.; Schultz, Aaron; Vasdev, Neil; Johnson, Keith A.
2017-01-01
Importance Previous postmortem studies have long demonstrated that neurofibrillary tangles made of hyperphosphorylated tau proteins are closely associated with Alzheimer disease clinical phenotype and neurodegeneration pattern. Validating these associations in vivo will lead to new diagnostic tools for Alzheimer disease and better understanding of its neurobiology. Objective To examine whether topographical distribution and severity of hyperphosphorylated tau pathologic findings measured by fluorine 18–labeled AV-1451 ([18F]AV-1451) positron emission tomographic (PET) imaging are linked with clinical phenotype and cortical atrophy in patients with Alzheimer disease. Design, Setting, and Participants This observational case series, conducted from July 1, 2012, to July 30, 2015, in an outpatient referral center for patients with neurodegenerative diseases, included 6 patients: 3 with typical amnesic Alzheimer disease and 3 with atypical variants (posterior cortical atrophy, logopenic variant primary progressive aphasia, and corticobasal syndrome). Patients underwent [18F]AV-1451 PET imaging to measure tau burden, carbon 11–labeled Pittsburgh Compound B ([11C]PiB) PET imaging to measure amyloid burden, and structural magnetic resonance imaging to measure cortical thickness. Seventy-seven age-matched controls with normal cognitive function also underwent structural magnetic resonance imaging but not tau or amyloid PET imaging. Main Outcomes and Measures Tau burden, amyloid burden, and cortical thickness. Results In all 6 patients (3 women and 3 men; mean age 61.8 years), the underlying clinical phenotype was associated with the regional distribution of the [18F]AV-1451 signal. Furthermore, within 68 cortical regions of interest measured from each patient, the magnitude of cortical atrophy was strongly correlated with the magnitude of [18F]AV-1451 binding (3 patients with amnesic Alzheimer disease, r = –0.82; P < .001; r = –0.70; P < .001; r = –0.58; P < .001; and 3 patients with nonamnesic Alzheimer disease, r = –0.51; P < .001; r = –0.63; P < .001; r = –0.70; P < .001), but not of [11C]PiB binding. Conclusions and Relevance These findings provide further in vivo evidence that distribution of the [18F]AV-1451 signal as seen on results of PET imaging is a valid marker of clinical symptoms and neurodegeneration. By localizing and quantifying hyperphosphorylated tau in vivo, results of tau PET imaging will likely serve as a key biomarker that links a specific type of molecular Alzheimer disease neuropathologic condition with clinically significant neurodegeneration, which will likely catalyze additional efforts to develop disease-modifying therapeutics. PMID:28241163
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-24
... Advance Notice, as Modified by Amendment No. 1, To Institute Supplemental Liquidity Deposits to Its Clearing Fund Designed to Increase Liquidity Resources To Meet Its Liquidity Needs May 20, 2013. On March...
ChIA-PET2: a versatile and flexible pipeline for ChIA-PET data analysis
Li, Guipeng; Chen, Yang; Snyder, Michael P.; Zhang, Michael Q.
2017-01-01
ChIA-PET2 is a versatile and flexible pipeline for analyzing different types of ChIA-PET data from raw sequencing reads to chromatin loops. ChIA-PET2 integrates all steps required for ChIA-PET data analysis, including linker trimming, read alignment, duplicate removal, peak calling and chromatin loop calling. It supports different kinds of ChIA-PET data generated from different ChIA-PET protocols and also provides quality controls for different steps of ChIA-PET analysis. In addition, ChIA-PET2 can use phased genotype data to call allele-specific chromatin interactions. We applied ChIA-PET2 to different ChIA-PET datasets, demonstrating its significantly improved performance as well as its ability to easily process ChIA-PET raw data. ChIA-PET2 is available at https://github.com/GuipengLi/ChIA-PET2. PMID:27625391
18F-FDG PET/MRI fusion in characterizing pancreatic tumors: comparison to PET/CT.
Tatsumi, Mitsuaki; Isohashi, Kayako; Onishi, Hiromitsu; Hori, Masatoshi; Kim, Tonsok; Higuchi, Ichiro; Inoue, Atsuo; Shimosegawa, Eku; Takeda, Yutaka; Hatazawa, Jun
2011-08-01
To demonstrate that positron emission tomography (PET)/magnetic resonance imaging (MRI) fusion was feasible in characterizing pancreatic tumors (PTs), comparing MRI and computed tomography (CT) as mapping images for fusion with PET as well as fused PET/MRI and PET/CT. We retrospectively reviewed 47 sets of (18)F-fluorodeoxyglucose ((18)F -FDG) PET/CT and MRI examinations to evaluate suspected or known pancreatic cancer. To assess the ability of mapping images for fusion with PET, CT (of PET/CT), T1- and T2-weighted (w) MR images (all non-contrast) were graded regarding the visibility of PT (5-point confidence scale). Fused PET/CT, PET/T1-w or T2-w MR images of the upper abdomen were evaluated to determine whether mapping images provided additional diagnostic information to PET alone (3-point scale). The overall quality of PET/CT or PET/MRI sets in diagnosis was also assessed (3-point scale). These PET/MRI-related scores were compared to PET/CT-related scores and the accuracy in characterizing PTs was compared. Forty-three PTs were visualized on CT or MRI, including 30 with abnormal FDG uptake and 13 without. The confidence score for the visibility of PT was significantly higher on T1-w MRI than CT. The scores for additional diagnostic information to PET and overall quality of each image set in diagnosis were significantly higher on the PET/T1-w MRI set than the PET/CT set. The diagnostic accuracy was higher on PET/T1-w or PET/T2-w MRI (93.0 and 90.7%, respectively) than PET/CT (88.4%), but statistical significance was not obtained. PET/MRI fusion, especially PET with T1-w MRI, was demonstrated to be superior to PET/CT in characterizing PTs, offering better mapping and fusion image quality.
2015-01-01
Multimodal nanoparticulate materials are described, offering magnetic, radionuclide, and fluorescent imaging capabilities to exploit the complementary advantages of magnetic resonance imaging (MRI), positron emission tomography/single-photon emission commuted tomography (PET/SPECT), and optical imaging. They comprise Fe3O4@NaYF4 core/shell nanoparticles (NPs) with different cation dopants in the shell or core, including Co0.16Fe2.84O4@NaYF4(Yb, Er) and Fe3O4@NaYF4(Yb, Tm). These NPs are stabilized by bisphosphonate polyethylene glycol conjugates (BP-PEG), and then show a high transverse relaxivity (r2) up to 326 mM–1 s–1 at 3T, a high affinity to [18F]-fluoride or radiometal-bisphosphonate conjugates (e.g., 64Cu and 99mTc), and fluorescent emissions from 500 to 800 nm under excitation at 980 nm. The biodistribution of intravenously administered particles determined by PET/MR imaging suggests that negatively charged Co0.16Fe2.84O4@NaYF4(Yb, Er)-BP-PEG (10K) NPs cleared from the blood pool more slowly than positively charged NPs Fe3O4@NaYF4(Yb, Tm)-BP-PEG (2K). Preliminary results in sentinel lymph node imaging in mice indicate the advantages of multimodal imaging. PMID:26172432
Van Laere, Koen; Ahmad, Rawaha U; Hudyana, Hendra; Celen, Sofie; Dubois, Kristof; Schmidt, Mark E; Bormans, Guy; Koole, Michel
2013-01-01
Phosphodiesterase 10A (PDE10A) is a cAMP/cGMP-hydrolysing enzyme with a central role in striatal signalling and implicated in neuropsychiatric disorders such as Huntington's disease, Parkinson's disease, schizophrenia and addiction. We have developed a novel PDE10A PET ligand, (18)F-JNJ42259152, and describe here its human dynamic biodistribution, safety and dosimetry. Six male subjects (age range 23-67 years) underwent ten dynamic whole-body PET/CT scans over 6 h after bolus injection of 175.5 ± 9.4 MBq (18)F-JNJ42259152. Source organs were delineated on PET/CT and individual organ doses and effective dose were determined using the OLINDA software. F-JNJ42259152 was readily taken up by the brain and showed exclusive retention in the brain, especially in the striatum with good washout starting after 20 min. The tracer was cleared through both the hepatobiliary and the urinary routes. No defluorination was observed. Organ absorbed doses were largest for the gallbladder (239 μSv/MBq) and upper large intestine (138 μSv/MBq). The mean effective dose was 24.9 ± 4.1 μSv/MBq. No adverse events were encountered. In humans, (18)F-JNJ42259152 has an appropriate distribution, brain kinetics and safety. The estimated effective dose was within WHO class IIb with low interindividual variability. Therefore, the tracer is suitable for further kinetic evaluation in humans.
Outdoor thermal comfort in public space in warm-humid Guayaquil, Ecuador
NASA Astrophysics Data System (ADS)
Johansson, Erik; Yahia, Moohammed Wasim; Arroyo, Ivette; Bengs, Christer
2018-03-01
The thermal environment outdoors affects human comfort and health. Mental and physical performance is reduced at high levels of air temperature being a problem especially in tropical climates. This paper deals with human comfort in the warm-humid city of Guayaquil, Ecuador. The main aim was to examine the influence of urban micrometeorological conditions on people's subjective thermal perception and to compare it with two thermal comfort indices: the physiologically equivalent temperature (PET) and the standard effective temperature (SET*). The outdoor thermal comfort was assessed through micrometeorological measurements of air temperature, humidity, mean radiant temperature and wind speed together with a questionnaire survey consisting of 544 interviews conducted in five public places of the city during both the dry and rainy seasons. The neutral and preferred values as well as the upper comfort limits of PET and SET* were determined. For both indices, the neutral values and upper thermal comfort limits were lower during the rainy season, whereas the preferred values were higher during the rainy season. Regardless of season, the neutral values of PET and SET* are above the theoretical neutral value of each index. The results show that local people accept thermal conditions which are above acceptable comfort limits in temperate climates and that the subjective thermal perception varies within a wide range. It is clear, however, that the majority of the people in Guayaquil experience the outdoor thermal environment during daytime as too warm, and therefore, it is important to promote an urban design which creates shade and ventilation.
Outdoor thermal comfort in public space in warm-humid Guayaquil, Ecuador.
Johansson, Erik; Yahia, Moohammed Wasim; Arroyo, Ivette; Bengs, Christer
2018-03-01
The thermal environment outdoors affects human comfort and health. Mental and physical performance is reduced at high levels of air temperature being a problem especially in tropical climates. This paper deals with human comfort in the warm-humid city of Guayaquil, Ecuador. The main aim was to examine the influence of urban micrometeorological conditions on people's subjective thermal perception and to compare it with two thermal comfort indices: the physiologically equivalent temperature (PET) and the standard effective temperature (SET*). The outdoor thermal comfort was assessed through micrometeorological measurements of air temperature, humidity, mean radiant temperature and wind speed together with a questionnaire survey consisting of 544 interviews conducted in five public places of the city during both the dry and rainy seasons. The neutral and preferred values as well as the upper comfort limits of PET and SET* were determined. For both indices, the neutral values and upper thermal comfort limits were lower during the rainy season, whereas the preferred values were higher during the rainy season. Regardless of season, the neutral values of PET and SET* are above the theoretical neutral value of each index. The results show that local people accept thermal conditions which are above acceptable comfort limits in temperate climates and that the subjective thermal perception varies within a wide range. It is clear, however, that the majority of the people in Guayaquil experience the outdoor thermal environment during daytime as too warm, and therefore, it is important to promote an urban design which creates shade and ventilation.
Vitale Shreve, Kristyn R; Mehrkam, Lindsay R; Udell, Monique A R
2017-08-01
Domestic cats (Felis silvestris catus) engage in a variety of relationships with humans and can be conditioned to engage in numerous behaviors using Pavlovian and operant methods Increasingly cat cognition research is providing evidence of their complex socio-cognitive and problem solving abilities. Nonetheless, it is still common belief that cats are not especially sociable or trainable. This disconnect may be due, in part, to a lack of knowledge of what stimuli cats prefer, and thus may be most motivated to work for. The current study investigated domestic cat preferences at the individual and population level using a free operant preference assessment. Adult cats from two populations (pet and shelter) were presented with three stimuli within each of the following four categories: human social interaction, food, toy, and scent. Proportion of time interacting with each stimulus was recorded. The single most-preferred stimulus from each of the four categories were simultaneously presented in a final session to determine each cat's most-preferred stimulus overall. Although there was clear individual variability in cat preference, social interaction with humans was the most-preferred stimulus category for the majority of cats, followed by food. This was true for cats in both the pet and shelter population. Future research can examine the use of preferred stimuli as enrichment in applied settings and assess individual cats' motivation to work for their most-preferred stimulus as a measure of reinforcer efficacy. Copyright © 2017 Elsevier B.V. All rights reserved.