Sample records for clearance

  1. Determination of glomerular function in advanced renal failure.

    PubMed Central

    Manz, F; Alatas, H; Kochen, W; Lutz, P; Rebien, W; Schärer, K

    1977-01-01

    In 15 children with advanced chronic renal failure, glomerular filtration rate was determined by different methods. Inulin clearance correlated well with the mean of creatinine and urea clearance, and also with 51-chromium edetic acid (EDTA) clearance measured over 24 hours. The absolute values of creatinine clearance and of 51Cr-EDTA clearance measured up to 8 hours were higher than inulin clearance. In advanced renal failure both the 51Cr-EDTA clearance measured over 24 hours, and the mean of creatinine and urea clearance, provide acceptable estimates of true glomerular filtration rate. PMID:411426

  2. Effect of Internal Clearance on Load Distribution and Life of Radially Loaded Ball and Roller Bearings

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.; Zaretsky, Erwin V.; Poplawski, Joseph V.

    2012-01-01

    The effect of internal clearance on radially loaded deepgroove ball and cylindrical roller bearing load distribution and fatigue life was determined for four clearance groups defined in the bearing standards. The analysis was extended to negative clearance (interference) conditions to produce a curve of life factor versus internal clearance. Rolling-element loads can be optimized and bearing life maximized for a small negative operating clearance. Life declines gradually with positive clearance and rapidly with increasing negative clearance. Relationships were found between bearing life and internal clearance as a function of ball or roller diameter, adjusted for load. Results are presented as life factors for radially loaded bearings independent of bearing size or applied load. In addition, a modified Stribeck Equation is presented that relates the maximum rolling-element load to internal bearing clearance.

  3. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    NASA Astrophysics Data System (ADS)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  4. Lactate clearance as a marker of mortality in pediatric intensive care unit.

    PubMed

    Munde, A; Kumar, N; Beri, R S; Puliyel, J M

    2014-07-01

    To correlate lactate clearance with Pediatric Intensive Care Unit (PICU) mortality. 45 (mean age 40.15 mo, 60% males) consecutive admissions in the PICU were enrolled between May 2012 to June 2013. Lactate clearance (Lactate level at admission - level 6 hr later x 100 / lactate level at admission) in first 6 hours of hospitalization was correlated to in-hospital mortality and PRISM score. Twelve out of 45 patients died. 90% died among those with delayed/poor clearance (clearance <30%) compared to 8.5% in those with good clearance (clearance >30%) (P<0.001). Lactate clearance <30% predicted mortality with sensitivity of 75%, specificity of 97%, positive predictive value of 90%, and negative predictive value of 91.42%. Predictability was comparable to PRISM score >30. Lactate clearance at six hours correlates with mortality in the PICU.

  5. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most adverse...

  6. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the most...

  7. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the most...

  8. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the most...

  9. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most adverse...

  10. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most adverse...

  11. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most adverse...

  12. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the most...

  13. 48 CFR 945.603-70 - Plant clearance function.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Plant clearance function... Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the contracting officer shall assume all responsibilities of the plant clearance officer...

  14. 48 CFR 945.603-70 - Plant clearance function.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Plant clearance function... Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the contracting officer shall assume all responsibilities of the plant clearance officer...

  15. Carbon Nanotubes in the Human Respiratory Tract-Clearance Modeling.

    PubMed

    Sturm, Robert

    2017-03-01

    Clearance of single-wall carbon nanotubes (SWCNT, diameter: 5 nm) and multi-wall carbon nanotubes (MWCNT, diameter: 50 nm) in the respiratory tract was predicted for various age groups (infants, children, adolescents, and adults). The model was founded on the assumption that lung clearance takes place in three distinct phases: (i) fast mucociliary clearance, (ii) slow bronchial clearance, and (iii) alveolar clearance. To each of these phases a specific fraction of deposited particles was attributed, the amount of which depended on particles' geometry and particles' deposition sites in the respiratory system. Clearance velocities were expressed by respective clearance half-times ranging from several hours in the case of fast clearance to tens of days in the case of slow clearance. Results of the simulations clearly demonstrate that for the specific deposition scenario (sitting, nasal breathing) considered here fast clearance fraction exhibits a slight decrease with increasing age, but total clearance times (i.e. time spans, within which 100% of the deposited particulate mass are removed) are rather constant among the age groups. Nanotubes deposited in the respiratory bronchioles and alveoli are usually subject to a long-term storage in these structures and, thus, may trigger malignant transformations in adjacent cells and tissues. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  16. Creatinine clearance test

    MedlinePlus

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... the body entirely by the kidneys. If kidney function is abnormal, creatinine level increases in the blood ...

  17. Toxicokinetics of PAHs in Hexagenia

    USGS Publications Warehouse

    Stehly, Guy R.; Landrum, Peter F.; Henry, Mary G.; Klemm, C.

    1990-01-01

    The clearance of oxygen from water is inversely and linearly related to the weight of the mayfly nymphs, but oxygen clearances were always much less than the uptake clearances of the PAHs. The high PAH uptake clearance compared to oxygen clearance implies a greater surface area or efficiency for PAH accumulation from water.

  18. 48 CFR 801.602-76 - Business clearance review.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Business clearance review... Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a... obtain a business clearance review prior to award of any contract, task or delivery order, or blanket...

  19. 48 CFR 801.602-76 - Business clearance review.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Business clearance review... Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a... obtain a business clearance review prior to award of any contract, task or delivery order, or blanket...

  20. Railway Tunnel Clearance Inspection Method Based on 3D Point Cloud from Mobile Laser Scanning

    PubMed Central

    Zhou, Yuhui; Wang, Shaohua; Mei, Xi; Yin, Wangling; Lin, Chunfeng; Mao, Qingzhou

    2017-01-01

    Railway tunnel clearance is directly related to the safe operation of trains and upgrading of freight capacity. As more and more railway are put into operation and the operation is continuously becoming faster, the railway tunnel clearance inspection should be more precise and efficient. In view of the problems existing in traditional tunnel clearance inspection methods, such as low density, slow speed and a lot of manual operations, this paper proposes a tunnel clearance inspection approach based on 3D point clouds obtained by a mobile laser scanning system (MLS). First, a dynamic coordinate system for railway tunnel clearance inspection has been proposed. A rail line extraction algorithm based on 3D linear fitting is implemented from the segmented point cloud to establish a dynamic clearance coordinate system. Second, a method to seamlessly connect all rail segments based on the railway clearance restrictions, and a seamless rail alignment is formed sequentially from the middle tunnel section to both ends. Finally, based on the rail alignment and the track clearance coordinate system, different types of clearance frames are introduced for intrusion operation with the tunnel section to realize the tunnel clearance inspection. By taking the Shuanghekou Tunnel of the Chengdu–Kunming Railway as an example, when the clearance inspection is carried out by the method mentioned herein, its precision can reach 0.03 m, and difference types of clearances can be effectively calculated. This method has a wide application prospects. PMID:28880232

  1. Evaluation of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Lattime, Scott B.; DeCastro, Jonathan A.; Oswald, Jay; Melcher, Kevin J.

    2005-01-01

    Reducing blade tip clearances through active tip clearance control in the high pressure turbine can lead to significant reductions in emissions and specific fuel consumption as well as dramatic improvements in operating efficiency and increased service life. Current engines employ scheduled cooling of the outer case flanges to reduce high pressure turbine tip clearances during cruise conditions. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, reburst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). In an effort to improve upon current thermal methods, a first generation mechanically-actuated active clearance control (ACC) system has been designed and fabricated. The system utilizes independent actuators, a segmented shroud structure, and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. Ambient temperature performance tests of this first generation ACC system assessed individual seal component leakage rates and both static and dynamic overall system leakage rates. The ability of the nine electric stepper motors to control the position of the seal carriers in both open- and closed-loop control modes for single and multiple cycles was investigated. The ability of the system to follow simulated engine clearance transients in closed-loop mode showed the system was able to track clearances to within a tight tolerance (0.001 in. error).

  2. Evaluation of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Lattime, Scott B.; Taylor, Shawn; DeCastro, Jonathan A.; Oswald, Jay; Melcher, Kevin J.

    2005-01-01

    Reducing blade tip clearances through active tip clearance control in the high pressure turbine can lead to significant reductions in emissions and specific fuel consumption as well as dramatic improvements in operating efficiency and increased service life. Current engines employ scheduled cooling of the outer case flanges to reduce high pressure turbine tip clearances during cruise conditions. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, reburst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). In an effort to improve upon current thermal methods, a first generation mechanically-actuated active clearance control (ACC) system has been designed and fabricated. The system utilizes independent actuators, a segmented shroud structure, and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. Ambient temperature performance tests of this first generation ACC system assessed individual seal component leakage rates and both static and dynamic overall system leakage rates. The ability of the nine electric stepper motors to control the position of the seal carriers in both open- and closed-loop control modes for single and multiple cycles was investigated. The ability of the system to follow simulated engine clearance transients in closed-loop mode showed the system was able to track clearances to within a tight tolerance ( 0.001 in. error).

  3. A parameters optimization method for planar joint clearance model and its application for dynamics simulation of reciprocating compressor

    NASA Astrophysics Data System (ADS)

    Hai-yang, Zhao; Min-qiang, Xu; Jin-dong, Wang; Yong-bo, Li

    2015-05-01

    In order to improve the accuracy of dynamics response simulation for mechanism with joint clearance, a parameter optimization method for planar joint clearance contact force model was presented in this paper, and the optimized parameters were applied to the dynamics response simulation for mechanism with oversized joint clearance fault. By studying the effect of increased clearance on the parameters of joint clearance contact force model, the relation of model parameters between different clearances was concluded. Then the dynamic equation of a two-stage reciprocating compressor with four joint clearances was developed using Lagrange method, and a multi-body dynamic model built in ADAMS software was used to solve this equation. To obtain a simulated dynamic response much closer to that of experimental tests, the parameters of joint clearance model, instead of using the designed values, were optimized by genetic algorithms approach. Finally, the optimized parameters were applied to simulate the dynamics response of model with oversized joint clearance fault according to the concluded parameter relation. The dynamics response of experimental test verified the effectiveness of this application.

  4. Clinical review: Drug metabolism and nonrenal clearance in acute kidney injury

    PubMed Central

    Vilay, A Mary; Churchwell, Mariann D; Mueller, Bruce A

    2008-01-01

    Decreased renal drug clearance is an obvious consequence of acute kidney injury (AKI). However, there is growing evidence to suggest that nonrenal drug clearance is also affected. Data derived from human and animal studies suggest that hepatic drug metabolism and transporter function are components of nonrenal clearance affected by AKI. Acute kidney injury may also impair the clearance of formed metabolites. The fact that AKI does not solely influence kidney function may have important implications for drug dosing, not only of renally eliminated drugs but also of those that are hepatically cleared. A review of the literature addressing the topic of drug metabolism and clearance alterations in AKI reveals that changes in nonrenal clearance are highly complicated and poorly studied, but they may be quite common. At present, our understanding of how AKI affects drug metabolism and nonrenal clearance is limited. However, based on the available evidence, clinicians should be cognizant that even hepatically eliminated drugs and formed drug metabolites may accumulate during AKI, and renal replacement therapy may affect nonrenal clearance as well as drug metabolite clearance. PMID:19040780

  5. A Matter of Millimeters: Defining the Processes for Critical Clearances on Curiosity

    NASA Technical Reports Server (NTRS)

    Florow, Brandon

    2013-01-01

    The Mars Science Laboratory (MSL) mission presents an immense packaging problem in that it takes a rover the size of a car with a sky crane landing system and packs it tightly into a spacecraft. This creates many areas of close and critical clearances. Critical Clearances are defined as hardware-to-hardware or hardware-to-envelope clearances which fall below a pre-established location dependent threshold and pose a risk of hardware to hardware contact during events such as launch, entry, landing, and operations. Close Clearances, on the other hand, are defined as any clearance value that is chosen to be tracked but is larger than the critical clearance threshold for its region. Close clearances may be tracked for various reasons including uncertainty in design, large expected dynamic motion, etc.

  6. N-linked glycan truncation causes enhanced clearance of plasma-derived von Willebrand factor.

    PubMed

    O'Sullivan, J M; Aguila, S; McRae, E; Ward, S E; Rawley, O; Fallon, P G; Brophy, T M; Preston, R J S; Brady, L; Sheils, O; Chion, A; O'Donnell, J S

    2016-12-01

    Essentials von Willebrands factor (VWF) glycosylation plays a key role in modulating in vivo clearance. VWF glycoforms were used to examine the role of specific glycan moieties in regulating clearance. Reduction in sialylation resulted in enhanced VWF clearance through asialoglycoprotein receptor. Progressive VWF N-linked glycan trimming resulted in increased macrophage-mediated clearance. Click to hear Dr Denis discuss clearance of von Willebrand factor in a free presentation from the ISTH Academy SUMMARY: Background Enhanced von Willebrand factor (VWF) clearance is important in the etiology of both type 1 and type 2 von Willebrand disease (VWD). In addition, previous studies have demonstrated that VWF glycans play a key role in regulating in vivo clearance. However, the molecular mechanisms underlying VWF clearance remain poorly understood. Objective To define the molecular mechanisms through which VWF N-linked glycan structures influence in vivo clearance. Methods By use of a series of exoglycosidases, different plasma-derived VWF (pd-VWF) glycoforms were generated. In vivo clearance of these glycoforms was then assessed in VWF -/- mice in the presence or absence of inhibitors of asialoglycoprotein receptor (ASGPR), or following clodronate-induced macrophage depletion. Results Reduced amounts of N-linked and O-linked sialylation resulted in enhanced pd-VWF clearance modulated via ASGPR. In addition to this role of terminal sialylation, we further observed that progressive N-linked glycan trimming also resulted in markedly enhanced VWF clearance. Furthermore, these additional N-linked glycan effects on clearance were ASGPR-independent, and instead involved enhanced macrophage clearance that was mediated, at least in part, through LDL receptor-related protein 1. Conclusion The carbohydrate determinants expressed on VWF regulate susceptibility to proteolysis by ADAMTS-13. In addition, our findings now further demonstrate that non-sialic acid carbohydrate determinants expressed on VWF also play an unexpectedly important role in modulating in vivo clearance through both hepatic ASGPR-dependent and macrophage-dependent pathways. In addition, these data further support the hypothesis that variation in VWF glycosylation may be important in the pathophysiology underlying type 1C VWD. © 2016 International Society on Thrombosis and Haemostasis.

  7. Chaos vibration of pinion and rack steering trapezoidal mechanism containing two clearances

    NASA Astrophysics Data System (ADS)

    Wei, Daogao; Wang, Yu; Jiang, Tong; Zheng, Sifa; Zhao, Wenjing; Pan, Zhijie

    2017-08-01

    The multi-clearances of breaking type steering trapezoidal mechanism joints influences vehicle steering stability. Hence, to ascertain the influence of clearance value on steering stability, this paper takes the steering mechanism of a certain vehicle type as a prototype that can be simplified into a planar six-bar linkage, then establishes the system dynamic differential equations after considering the two clearances of tie rods and the steering knuckle arms. The influence of the clearance parameters on the movement stability of the steering mechanism is studied using a numerical computation method. Results show that when the two clearances are equal, the planar movement of the tie rods changes from period-doubling to chaos as the clearances increase. When the two clearances are 0.25 mm and 1.5 mm respectively, the planar movements of the two side tie rods come into chaos, causing the steering stability to deteriorate. Moreover, with the increase of clearances, turning moment fluctuates more intensively and the peak value increases.

  8. Numerical investigation of tip clearance effects on the performance of ducted propeller

    NASA Astrophysics Data System (ADS)

    Ding, Yongle; Song, Baowei; Wang, Peng

    2015-09-01

    Tip clearance loss is a limitation of the improvement of turbomachine performance. Previous studies show the Tip clearance loss is generated by the leakage flow through the tip clearance, and is roughly linearly proportional to the gap size. This study investigates the tip clearance effects on the performance of ducted propeller. The investigation was carried out by solving the Navier-Stokes equations with the commercial Computational Fluid Dynamic (CFD) code CFX14.5. These simulations were carried out to determine the underlying mechanisms of the tip clearance effects. The calculations were performed at three different chosen advance ratios. Simulation results showed that the tip loss slope was not linearly at high advance due to the reversed pressure at the leading edge. Three type of vortical structures were observed in the tip clearance at different clearance size.

  9. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    NASA Technical Reports Server (NTRS)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  10. Design optimization of dual-axis driving mechanism for satellite antenna with two planar revolute clearance joints

    NASA Astrophysics Data System (ADS)

    Bai, Zheng Feng; Zhao, Ji Jun; Chen, Jun; Zhao, Yang

    2018-03-01

    In the dynamic analysis of satellite antenna dual-axis driving mechanism, it is usually assumed that the joints are ideal or perfect without clearances. However, in reality, clearances in joints are unavoidable due to assemblage, manufacturing errors and wear. When clearance is introduced to the mechanism, it will lead to poor dynamic performances and undesirable vibrations due to impact forces in clearance joint. In this paper, a design optimization method is presented to reduce the undesirable vibrations of satellite antenna considering clearance joints in dual-axis driving mechanism. The contact force model in clearance joint is established using a nonlinear spring-damper model and the friction effect is considered using a modified Coulomb friction model. Firstly, the effects of clearances on dynamic responses of satellite antenna are investigated. Then the optimization method for dynamic design of the dual-axis driving mechanism with clearance is presented. The objective of the optimization is to minimize the maximum absolute vibration peak of antenna acceleration by reducing the impact forces in clearance joint. The main consideration here is to optimize the contact parameters of the joint elements. The contact stiffness coefficient, damping coefficient and the dynamic friction coefficient for clearance joint elements are taken as the optimization variables. A Generalized Reduced Gradient (GRG) algorithm is used to solve this highly nonlinear optimization problem for dual-axis driving mechanism with clearance joints. The results show that the acceleration peaks of satellite antenna and contact forces in clearance joints are reduced obviously after design optimization, which contributes to a better performance of the satellite antenna. Also, the application and limitation of the proposed optimization method are discussed.

  11. Relationship between rhinosinusitis symptoms and mucociliary clearance time.

    PubMed

    Boatsman, Justin E; Calhoun, Karen H; Ryan, Matthew W

    2006-03-01

    To determine the correlation between rhinosinusitis symptoms as assessed by the Sino-Nasal Outcomes Test-20 (SNOT-20) and mucociliary clearance as assessed by the saccharin method. This was a cross-sectional study of 50 adult volunteers. Subjects completed the SNOT-20, and mucociliary clearance was determined with the saccharine method. Correlation coefficients (Spearman's Rho) were calculated for the global SNOT-20 score. The SNOT-20 scores varied from 20 to 54 (mean 30.28) with a possible range of 20 to 100. Clearance times varied from 418 to 2865 seconds (mean 999). There was no significant correlation between global SNOT-20 score and clearance time (r = 0.196). There is no significant correlation between rhinosinusitis symptoms as assessed by SNOT-20 scores and mucociliary clearance. Mucociliary clearance is important for the health of the sinonasal cavities, but clearance time does not appear to be associated with symptom severity in the population studied. A-1b.

  12. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case. ...

  13. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case. ...

  14. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case. ...

  15. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case. ...

  16. 78 FR 77027 - Overhead Clearance (Air-Draft) Accidents

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... No. USCG-2013-0466] Overhead Clearance (Air-Draft) Accidents AGENCY: Coast Guard, DHS. ACTION... clearance (air-draft) accidents. In its petition, which calls for vessel masters to be provided with accurate vertical air draft information, a maritime organization has described 16 overhead clearance...

  17. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor...

  18. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor...

  19. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor...

  20. Numerical investigation of hub clearance flow in a Kaplan turbine

    NASA Astrophysics Data System (ADS)

    Wu, H.; Feng, J. J.; Wu, G. K.; Luo, X. Q.

    2012-11-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  1. CF6 High Pressure Compressor and Turbine Clearance Evaluations

    NASA Technical Reports Server (NTRS)

    Radomski, M. A.; Cline, L. D.

    1981-01-01

    In the CF6 Jet Engine Diagnostics Program the causes of performance degradation were determined for each component of revenue service engines. It was found that a significant contribution to performance degradation was caused by increased airfoil tip radial clearances in the high pressure compressor and turbine areas. Since the influence of these clearances on engine performance and fuel consumption is significant, it is important to accurately establish these relatonships. It is equally important to understand the causes of clearance deterioration so that they can be reduced or eliminated. The results of factory engine tests run to enhance the understanding of the high pressure compressor and turbine clearance effects on performance are described. The causes of clearance deterioration are indicated and potential improvements in clearance control are discussed.

  2. Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.

    PubMed

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-09-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  3. The fate of sulfate in chronic heart failure

    PubMed Central

    Koning, Anne M.; Meijers, Wouter C.; Minović, Isidor; Post, Adrian; Feelisch, Martin; Pasch, Andreas; Leuvenink, Henri G. D.; de Boer, Rudolf A.; Bakker, Stephan J. L.

    2017-01-01

    New leads to advance our understanding of heart failure (HF) pathophysiology are urgently needed. Previous studies have linked urinary sulfate excretion to a favorable cardiovascular risk profile. Sulfate is not only the end product of hydrogen sulfide metabolism but is also directly involved in various (patho)physiological processes, provoking scientific interest in its renal handling. This study investigates sulfate clearance in chronic HF (CHF) patients and healthy individuals and considers its relationship with disease outcome. Parameters related to renal sulfate handling were determined in and compared between 96 previously characterized CHF patients and sex-matched healthy individuals. Among patients, sulfate clearance was analyzed for associations with clinical and outcome parameters. In CHF patients, plasma sulfate concentrations are significantly higher, whereas 24-h urinary excretion, fractional excretion, and clearance of sulfate are significantly lower, compared with healthy individuals. Among patients, sulfate clearance is independently associated with diuretics use, creatinine clearance and 24-h urinary sodium excretion. Sulfate clearance is associated with favorable disease outcome [hazard ratio per SD increase 0.38 (95% confidence interval 0.23–0.63), P < 0.001]. Although significance was lost after adjustment for creatinine clearance, the decrease of sulfate clearance in patients is independent of this parameter, indicating that sulfate clearance is not merely a reflection of renal function. This exploratory study reveals aberrant sulfate clearance as a potential contributor to CHF pathophysiology, with reduced levels in patients and a positive association with favorable disease outcome. Further research is needed to unravel the nature of its involvement and to determine its potential as a biomarker and target for therapy. NEW & NOTEWORTHY Sulfate clearance is decreased in chronic heart failure patients compared with healthy individuals. Among patients, sulfate clearance is positively associated with favorable disease outcome, i.e., a decreased rehospitalization rate and increased patient survival. Hence, decreased sulfate clearance may be involved in the pathophysiology of heart failure. PMID:27923792

  4. 76 FR 17182 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-28

    ... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service...: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. Abstract...

  5. 48 CFR 945.670-1 - Plant clearance function.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Plant clearance function... MANAGEMENT GOVERNMENT PROPERTY Reporting, Reutilization, and Disposal 945.670-1 Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the...

  6. 48 CFR 945.670-1 - Plant clearance function.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Plant clearance function... MANAGEMENT GOVERNMENT PROPERTY Reporting, Reutilization, and Disposal 945.670-1 Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the...

  7. Integrated Turbine Tip Clearance and Gas Turbine Engine Simulation

    NASA Technical Reports Server (NTRS)

    Chapman, Jeffryes W.; Kratz, Jonathan; Guo, Ten-Huei; Litt, Jonathan

    2016-01-01

    Gas turbine compressor and turbine blade tip clearance (i.e., the radial distance between the blade tip of an axial compressor or turbine and the containment structure) is a major contributing factor to gas path sealing, and can significantly affect engine efficiency and operational temperature. This paper details the creation of a generic but realistic high pressure turbine tip clearance model that may be used to facilitate active tip clearance control system research. This model uses a first principles approach to approximate thermal and mechanical deformations of the turbine system, taking into account the rotor, shroud, and blade tip components. Validation of the tip clearance model shows that the results are realistic and reflect values found in literature. In addition, this model has been integrated with a gas turbine engine simulation, creating a platform to explore engine performance as tip clearance is adjusted. Results from the integrated model explore the effects of tip clearance on engine operation and highlight advantages of tip clearance management.

  8. 76 FR 39893 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-07

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery.... SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  9. 76 FR 19359 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-07

    ... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. Abstract...

  10. 45 CFR 675.3 - Medical clearance criteria.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 3 2014-10-01 2014-10-01 false Medical clearance criteria. 675.3 Section 675.3 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION MEDICAL CLEARANCE PROCESS FOR DEPLOYMENT TO ANTARCTICA § 675.3 Medical clearance criteria. (a) The USAP shall...

  11. 45 CFR 675.3 - Medical clearance criteria.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 3 2013-10-01 2013-10-01 false Medical clearance criteria. 675.3 Section 675.3 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION MEDICAL CLEARANCE PROCESS FOR DEPLOYMENT TO ANTARCTICA § 675.3 Medical clearance criteria. (a) The USAP shall...

  12. 76 FR 59379 - Proposed Information Collection; Comment Request; Generic Clearance for Research in Development...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-26

    ...-XXXX. Type of Review: Generic Clearance Request. Title: Generic Clearance for Research in Development..., filing of petitions and applications and agency #0;statements of organization and functions are examples... Proposed Information Collection; Comment Request; Generic Clearance for Research in Development of...

  13. 45 CFR 675.3 - Medical clearance criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 3 2011-10-01 2011-10-01 false Medical clearance criteria. 675.3 Section 675.3 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION MEDICAL CLEARANCE PROCESS FOR DEPLOYMENT TO ANTARCTICA § 675.3 Medical clearance criteria. (a) The USAP shall...

  14. Long-term clearance from small airways in patients with cystic fibrosis.

    PubMed

    Lindström, M; Camner, P; Falk, R; Hjelte, L; Philipson, K; Svartengren, M

    2005-02-01

    Impaired mucociliary clearance is a hallmark of cystic fibrosis (CF). Early morphological changes first appear in the small airways. Lung clearance was investigated in 11 young CF adults with mild-to-moderate lung disease using a method depositing particles mainly in the small airways. Radiolabelled Teflon particles (6 microm) were inhaled with an extremely slow inhalation flow, 0.05 L x s(-1). Lung retention was measured immediately following inhalations and, on four occasions up to 21 days. The results were compared with data from healthy subjects. The lung retention at 24 h in % of deposition was 67% (95% confidence interval 58-76) in the CF patients, compared to 48% (42-53) in the healthy subjects. Clearance on days 1-7 was larger in the CF patients, 22% (15-29) compared to the healthy subjects, 14% (12-16). No difference was observed between the CF patients and the healthy subjects in the slow clearance phase at day 7 to day 21, representing small airway clearance. Impaired mucociliary clearance in CF patients results in increased 24-h retention and a prolonged rapid clearance phase. The results of the study do not support the current authors' hypothesis that clearance from small airways is slower in cystic fibrosis patients compared to healthy subjects. Furthermore, the data suggest that mucociliary transport is not the dominant clearance mechanism in small airways.

  15. The effects of selected air pollutants on clearance of titanic oxide particles from the lungs of rats.

    PubMed

    Ferin, J; Leach, L J

    1975-09-01

    A procedure utilizing the lung clearance kinetics of titanic oxide (TiO2) particles was used to determine the effects of inhaled sulphur dioxide (SO2) and nitrogen oxides (NO x) on particle clearance. The procedure is reproducible and mainly tests clearance mechanisms involving alveolar macrophages and the mucociliary transport system at the alveolobronchial clearance pathway. At low SO2 or NOx exposures enhanced particle clearance was observed. Lung clearance was depressed at 15 and 24 ppm of NO2 after 22 exposures as well as at 20 ppm of SO2 after 11 exposures, and also at 1 ppm of SO2 after 25 exposures. Dose-response curves for the SO2 and NOx exposures showed differences explainable by the routes by which these gases reach the alveolar macrophages.

  16. Study of blade clearance effects on centrifugal pumps

    NASA Technical Reports Server (NTRS)

    Hoshide, R. K.; Nielson, C. E.

    1972-01-01

    A program of analysis, design, fabrication, and testing has been conducted to develop and experimentally verify analytical models to predict the effects of impeller blade clearance on centrifugal pumps. The effect of tip clearance on pump efficiency, and the relationship between the head coefficient and torque loss with tip clearance was established. Analysis were performed to determine the cost variation in design, manufacture, and test that would occur between unshrouded and shrouded impellers. An impeller, representative of typical rocket engine impellers, was modified by removing its front shroud to permit variation of its blade clearances. It was tested in water with special instrumentation to provide measurements of blade surface pressures during operation. Pump performance data were obtained from tests at various impeller tip clearances. Blade pressure data were obtained at the nominal tip clearance. Comparisons of predicted and measured data are given.

  17. Modeling Immunization To Infliximab in Children With Crohn's Disease Using Population Pharmacokinetics: A Pilot Study.

    PubMed

    Petitcollin, Antoine; Leuret, Oriane; Tron, Camille; Lemaitre, Florian; Verdier, Marie-Clémence; Paintaud, Gilles; Bouguen, Guillaume; Willot, Stéphanie; Bellissant, Eric; Ternant, David

    2018-05-18

    Antidrug antibodies (ADAs) dramatically increase infliximab clearance and are responsible for underexposure to the drug, leading to treatment failure. This pilot study aimed at developing a population pharmacokinetic model to detect and describe an early increase in infliximab clearance due to ADA. Twenty children with Crohn's disease (CD) were followed for 1 year or until treatment failure. Infliximab trough concentration, ADA, C-reactive protein (CRP), and Paediatric Crohn's Disease Activity Index (PCDAI) were recorded at each visit. A time-varying clearance population pharmacokinetic model was built to detect and describe an increase in infliximab clearance, independent from ADA testing. Factors associated with clearance variation and the relationships between infliximab concentrations, clearance variation, and clinical response were investigated. The model detected important increases in clearance in 4 patients. These patients had suboptimal early response, with higher mean PCDAI (P = 0.0086) and CRP (P = 0.028) compared with other patients. Two of them had detectable ADA. Clearance increase as described by the model and lower infliximab trough concentration at week 2 were associated with poorer outcomes in a multivariate Cox model (P = 0.001 and P = 0.0048, respectively). Being able to detect an increase in infliximab clearance, this model could allow the early detection of immunization to infliximab and therefore could help with dose adjustment in patients with CD. Moreover, the results suggest that clearance variations could be used as a predictive marker of clinical response. These findings need to be confirmed in a larger cohort, however, and predictive factors of clearance increase have to be investigated.

  18. Application of a Physiologically Based Pharmacokinetic Model to Assess Propofol Hepatic and Renal Glucuronidation in Isolation: Utility of In Vitro and In Vivo Data

    PubMed Central

    Gill, Katherine L.; Gertz, Michael; Houston, J. Brian

    2013-01-01

    A physiologically based pharmacokinetic (PBPK) modeling approach was used to assess the prediction accuracy of propofol hepatic and extrahepatic metabolic clearance and to address previously reported underprediction of in vivo clearance based on static in vitro–in vivo extrapolation methods. The predictive capacity of propofol intrinsic clearance data (CLint) obtained in human hepatocytes and liver and kidney microsomes was assessed using the PBPK model developed in MATLAB software. Microsomal data obtained by both substrate depletion and metabolite formation methods and in the presence of 2% bovine serum albumin were considered in the analysis. Incorporation of hepatic and renal in vitro metabolic clearance in the PBPK model resulted in underprediction of propofol clearance regardless of the source of in vitro data; the predicted value did not exceed 35% of the observed clearance. Subsequently, propofol clinical data from three dose levels in intact patients and anhepatic subjects were used for the optimization of hepatic and renal CLint in a simultaneous fitting routine. Optimization process highlighted that renal glucuronidation clearance was underpredicted to a greater extent than liver clearance, requiring empirical scaling factors of 17 and 9, respectively. The use of optimized clearance parameters predicted hepatic and renal extraction ratios within 20% of the observed values, reported in an additional independent clinical study. This study highlights the complexity involved in assessing the contribution of extrahepatic clearance mechanisms and illustrates the application of PBPK modeling, in conjunction with clinical data, to assess prediction of clearance from in vitro data for each tissue individually. PMID:23303442

  19. 33 CFR 117.415 - Green River.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... vertical clearance beneath the draw. When vertical clearance is more than 40 feet, at least four hours... clearance. When the vertical clearance is more than 40 feet, at least four hours notice shall be given... vessel will return within four hours, the drawtender shall remain on duty until the vessel returns but is...

  20. 76 FR 55078 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-06

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for.... SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  1. 76 FR 10626 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-25

    ... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. Abstract...

  2. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  3. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  4. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  5. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  6. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  7. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a fair...

  8. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a fair...

  9. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a fair...

  10. 10 CFR 1016.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... authorizations or clearances will be defined. (1) “Q” access authorizations or clearances are based upon full... quantities as required in the performance of duties. (2) “Q(X)” access authorizations or clearances are based...” access authorizations or clearances are based upon National Agency Checks and Inquiries (NACI) for...

  11. 10 CFR 1016.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... authorizations or clearances will be defined. (1) “Q” access authorizations or clearances are based upon full... quantities as required in the performance of duties. (2) “Q(X)” access authorizations or clearances are based...” access authorizations or clearances are based upon National Agency Checks and Inquiries (NACI) for...

  12. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  13. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  14. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  15. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  16. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  17. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  18. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  19. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  20. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  1. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  2. 14 CFR 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 5 2011-01-01 2010-01-01 true Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  3. 14 CFR 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  4. 14 CFR 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 5 2013-01-01 2013-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  5. 14 CFR 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 5 2012-01-01 2012-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  6. 48 CFR 2452.237-75 - Clearance of contractor personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Clearance of contractor... Clauses 2452.237-75 Clearance of contractor personnel. As prescribed in 2437.110(e), insert the following clause in solicitations and contracts. Clearance of Contractor Personnel (OCT 1999) (a) General. This...

  7. 46 CFR 56.75-10 - Joint clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Joint clearance. 56.75-10 Section 56.75-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Brazing § 56.75-10 Joint clearance. (a) The clearance between surfaces to be joined shall be no...

  8. Fuel conservation through active control of rotor clearances

    NASA Technical Reports Server (NTRS)

    Beitler, R. S.; Saunders, A. A.; Wanger, R. P.

    1980-01-01

    Under the NASA-sponsored Energy Efficient Engine (EEE) Project, technology is being developed which will significantly reduce the fuel consumption of turbofan engines for subsonic transport aircraft. One technology concept being pursued is active control of rotor tip clearances. Attention is given to rotor tip clearance considerations and an overview of preliminary study results as well as the General Electric EEE clearance control approach is presented. Finally, potential fuel savings with active control of rotor clearances for a typical EEE mission are predicted.

  9. Effect of isolated hepatic ischemia on organic anion clearance and oxidative metabolism.

    PubMed

    Minard, G; Bynoe, R; Wood, G C; Fabian, T C; Croce, M; Kudsk, K A

    1992-04-01

    Hepatic failure is frequently seen following severe hemorrhagic shock, sepsis, and trauma. Clearance of various drugs has been used to evaluate hepatocellular dysfunction, including indocyanine green (ICG), an organic anionic dye that is transported similarly to bilirubin, and antipyrine (AP), a marker of oxidative phosphorylation. Previous investigators have noted a decrease in ICG excretion following systemic hemorrhage. The effect of isolated hepatic ischemia on the clearances of ICG and AP was studied in 16 pigs after 90 minutes of vascular occlusion to the liver. Antipyrine clearance decreased almost 50% from baseline values at 24 and 72 hours after the ischemia procedure, indicating a significant depression in the cytochrome P-450 system. On the other hand, ICG clearance did not change significantly. In conclusion, ICG clearance is not depressed after isolated hepatic ischemia in pigs. Changes in organic anion clearance after systemic hemorrhage may be because of release of toxic products from ischemic peripheral tissue.

  10. 48 CFR 245.7101-4 - DD Form 1640, Request for Plant Clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false DD Form 1640, Request for Plant Clearance. 245.7101-4 Section 245.7101-4 Federal Acquisition Regulations System DEFENSE... Forms 245.7101-4 DD Form 1640, Request for Plant Clearance. Use to request plant clearance assistance or...

  11. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  12. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  13. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  14. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  15. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  16. 14 CFR § 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 5 2014-01-01 2014-01-01 false Customs clearance and visas. § 1260.63... COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For grants or cooperative agreements with foreign organizations, this clause will be developed on...

  17. Analysis of foot clearance in firefighters during ascent and descent of stairs.

    PubMed

    Kesler, Richard M; Horn, Gavin P; Rosengren, Karl S; Hsiao-Wecksler, Elizabeth T

    2016-01-01

    Slips, trips, and falls are a leading cause of injury to firefighters with many injuries occurring while traversing stairs, possibly exaggerated by acute fatigue from firefighting activities and/or asymmetric load carriage. This study examined the effects that fatigue, induced by simulated firefighting activities, and hose load carriage have on foot clearance while traversing stairs. Landing and passing foot clearances for each stair during ascent and descent of a short staircase were investigated. Clearances decreased significantly (p < 0.05) post-exercise for nine of 12 ascent parameters and increased for two of eight descent parameters. Load carriage resulted in significantly decreased (p < 0.05) clearance over three ascent parameters, and one increase during descent. Decreased clearances during ascent caused by fatigue or load carriage may result in an increased trip risk. Increased clearances during descent may suggest use of a compensation strategy to ensure stair clearance or an increased risk of over-stepping during descent. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  18. Should we consider steps with variable height for a safer stair negotiation in older adults?

    PubMed

    Kunzler, Marcos R; da Rocha, Emmanuel S; Dos Santos, Christielen S; Ceccon, Fernando G; Priario, Liver A; Carpes, Felipe P

    2018-01-01

    Effects of exercise on foot clearances are important. In older adults variations in foot clearances during walking may lead to a fall, but there is a lack of information concerning stair negotiation in older adults. Whether a condition of post exercise changes foot clearances between steps of a staircase in older adults still unknown. To determine differences in clearances when older adults negotiate different steps of a staircase before and after a session of aerobic exercise. Kinematics data from 30 older adults were acquired and the toe and heel clearances were determined for each step. Clearances were compared between the steps. Smaller clearances were found at the highest step during ascending and descending, which was not changed by exercise. Smaller clearances suggest higher risk of tripping at the top of the staircase, regardless of exercise. A smaller step at the top of a short flight of stairs could reduce chances of tripping in older adults. It suggests that steps with variable height could make stair negotiation safer in older adults. This hypothesis should be tested in further studies.

  19. Radioaerosol lung clearance in patients with active pulmonary sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, M.P.; Baughman, R.P.; Hughes, J.

    1985-05-01

    Pulmonary radioaerosol clearance rate of /sup 99m/Tc diethylenetriamine pentacetate (DTPA) in 14 patients with untreated sarcoidosis was compared with /sup 67/Ga lung scan and increased lymphocytes in the bronchoalveolar lavage (BAL) fluid. Nine healthy nonsmoking subjects had a mean DTPA clearance rate of 1.18%/min (range, 0.54 to 1.60%/min). Eight of 14 patients with sarcoidosis had clearance rates greater than 1.60%/min. Of those 8 patients with abnormal DTPA clearance, 4 had positive gallium scans, 4 had more than 17% lymphocytes in the BAL fluid, and 3 had both tests positive. To study the cause of abnormal DTPA clearance, 23 subjects (includingmore » 3 normal controls, all 14 patients with sarcoidosis, and 6 patients with localized disease on chest roentgenogram) underwent both DTPA clearance studies and BAL for quantitation of the amount of albumin in lung fluid. There was a positive correlation between the rate of DTPA clearance and the albumin concentration in lung fluid (r = 0.87, p less than 0.01).« less

  20. Lactate clearance cut off for early mortality prediction in adult sepsis and septic shock patients

    NASA Astrophysics Data System (ADS)

    Sinto, R.; Widodo, D.; Pohan, H. T.

    2018-03-01

    Previous lactate clearance cut off for early mortality prediction in sepsis and septic shock patient was determined by consensus from small sample size-study. We investigated the best lactate clearance cut off and its ability to predict early mortality in sepsis and septic shock patients. This cohort study was conducted in Intensive Care Unit of CiptoMangunkusumo Hospital in 2013. Patients’ lactate clearance and eight other resuscitationendpoints were recorded, and theoutcome was observed during the first 120 hours. The clearance cut off was determined using receiver operating characteristic (ROC) analysis, and its ability was investigated with Cox’s proportional hazard regression analysis using other resuscitation endpoints as confounders. Total of 268 subjects was included, of whom 70 (26.11%) subjects died within the first 120 hours. The area under ROC of lactate clearance to predict early mortality was 0.78 (95% % confidence interval [CI] 0.71-0.84) with best cut off was <7.5% (sensitivity and specificity 88.99% and 81.4% respectively). Compared with group achieving lactate clearance target, group not achieving lactate clearance target had to increase early mortality risk (adjusted hazard ratio 13.42; 95%CI 7.19-25.07). In conclusion, the best lactate clearance cut off as anearly mortality predictor in sepsis and septic shock patients is 7.5%.

  1. Clearance systems in the brain-implications for Alzheimer disease.

    PubMed

    Tarasoff-Conway, Jenna M; Carare, Roxana O; Osorio, Ricardo S; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J

    2015-08-01

    Accumulation of toxic protein aggregates-amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles-is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood-brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ.

  2. Lack of effect of non-steroid antiinflammatory drugs on lithium clearance and on delivery of tubular fluid to the loop of Henle in rats.

    PubMed

    Lassen, E; Thomsen, K; Sørensen, S S; Pedersen, E B

    1986-11-01

    This paper examines a possible interaction between non-steroid antiinflammatory drugs (NSAI drugs) and renal lithium clearance in conscious, unoperated rats with diabetes insipidus (Brattleboro strain) and ordinary Wistar rats. The drugs were given with the food for 5 days before clearance determinations in the following daily doses per kg body weight: acetylsalicyclic acid 115 mg/kg, phenylbutazone 20 mg/kg, indomethacin 5 mg/kg, and penicillamine 65 mg/kg. None of the drugs affected the lithium clearance. Also urine flow, sodium clearance, potassium clearance, and prostaglandin E2 excretion remained unaffected by the treatments. The results suggest that a continued lowering of lithium clearance cannot be produced, at least not by administration of the drugs with the food. Since lithium clearance is a quantitative measure of the delivery of tubular fluid from the proximal tubules to the loop of Henle, the results also suggest that chronic administration of NSAI drugs does not influence delivery from the proximal tubules in rats. The lowering of lithium clearance observed by others after administration of the drugs by injection or by gastric tube may have been transient, lasting only for a short period after each administration.

  3. Clearance systems in the brain—implications for Alzheimer disease

    PubMed Central

    Tarasoff-Conway, Jenna M.; Carare, Roxana O.; Osorio, Ricardo S.; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V.; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J.

    2015-01-01

    Accumulation of toxic protein aggregates—amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles—is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood–brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ. PMID:26195256

  4. Estradiol and weight are covariates of paracetamol clearance in young women.

    PubMed

    Beleyn, B; Vermeersch, S; Kulo, A; Smits, A; Verbesselt, R; de Hoon, J N; Van Calsteren, K; Allegaert, K

    2014-01-01

    Paracetamol clearance differs between pregnant and non-pregnant women and between women with or without specific oral contraceptives (OCs). However, an association between female sex hormones and paracetamol clearance has never been explored. In total, 49 women at delivery, 8 female control subjects without OC use, historical data of 14 women taking OCs, and 15 postpartum observations with and without OCs were pooled to explore covariates of paracetamol clearance. All received a single intravenous 2-gram paracetamol dose, and blood samples were collected up to 6 h after dosing. High-performance liquid chromatography was used to quantify paracetamol. The area under the curve to time infinity (AUC0-∞) was determined and clearance (l/h·m(2)) was calculated by dose/ AUC0-∞. In addition, estradiol and progesterone were quantified by ELISA with electro-chemiluminescence. Median paracetamol clearance at delivery was significantly higher when compared to postpartum or non-pregnant women (11.9 vs. 6.42 and 8.4 l/h·m(2), at least p < 0.05), while an association between paracetamol clearance and estradiol was observed (R = 0.494, p < 0.0001). In non-pregnant subjects, there was no impact of OC exposure on paracetamol clearance. Multiple regression revealed a linear association (Radj = 0.41, p < 0.001) between paracetamol clearance and weight (p = 0.0462) and estradiol (p < 0.0001). Estradiol and weight in part explain the variation in paracetamol clearance in young women. © 2014 S. Karger AG, Basel.

  5. The Role of Radial Clearance on the Performance of Foil Air Bearings

    NASA Technical Reports Server (NTRS)

    Radil, Kevin; Howard, Samuel; Dykas, Brian

    2002-01-01

    Load capacity tests were conducted to determine how radial clearance variations affect the load capacity coefficient of foil air bearings. Two Generation III foil air bearings with the same design but possessing different initial radial clearances were tested at room temperature against an as-ground PS304 coated journal operating at 30,000 rpm. Increases in radial clearance were accomplished by reducing the journal's outside diameter via an in-place grinding system. From each load capacity test the bearing load capacity coefficient was calculated from the rule-of-thumb (ROT) model developed for foil air bearings. The test results indicate that, in terms of the load capacity coefficient, radial clearance has a direct impact on the performance of the foil air bearing. Each test bearing exhibited an optimum radial clearance that resulted in a maximum load capacity coefficient. Relative to this optimum value are two separate operating regimes that are governed by different modes of failure. Bearings operating with radial clearances less than the optimum exhibit load capacity coefficients that are a strong function of radial clearance and are prone to a thermal runaway failure mechanism and bearing seizure. Conversely, a bearing operating with a radial clearance twice the optimum suffered only a 20 percent decline in its maximum load capacity coefficient and did not experience any thermal management problems. However, it is unknown to what degree these changes in radial clearance had on other performance parameters, such as the stiffness and damping properties of the bearings.

  6. Age-Related Decline in Brain and Hepatic Clearance of Amyloid-Beta is Rectified by the Cholinesterase Inhibitors Donepezil and Rivastigmine in Rats.

    PubMed

    Mohamed, Loqman A; Qosa, Hisham; Kaddoumi, Amal

    2015-05-20

    In Alzheimer's disease (AD), accumulation of brain amyloid-β (Aβ) depends on imbalance between production and clearance of Aβ. Several pathways for Aβ clearance have been reported including transport across the blood-brain barrier (BBB) and hepatic clearance. The incidence of AD increases with age and failure of Aβ clearance correlates with AD. The cholinesterase inhibitors (ChEIs) donepezil and rivastigmine are used to ease the symptoms of dementia associated with AD. Besides, both drugs have been reported to provide neuroprotective and disease-modifying effects. Here, we investigated the effect of ChEIs on age-related reduced Aβ clearance. Findings from in vitro and in vivo studies demonstrated donepezil and rivastigmine to enhance (125)I-Aβ40 clearance. Also, the increase in brain and hepatic clearance of (125)I-Aβ40 was more pronounced in aged compared to young rats, and was associated with significant reduction in brain Aβ endogenous levels determined by ELISA. Furthermore, the enhanced clearance was concomitant with up-regulation in the expression of Aβ major transport proteins P-glycoprotein and LRP1. Collectively, our findings that donepezil and rivastigmine enhance Aβ clearance across the BBB and liver are novel and introduce an additional mechanism by which both drugs could affect AD pathology. Thus, optimizing their clinical use could help future drug development by providing new drug targets and possible mechanisms involved in AD pathology.

  7. Hepatobiliary Clearance Prediction: Species Scaling From Monkey, Dog, and Rat, and In Vitro-In Vivo Extrapolation of Sandwich-Cultured Human Hepatocytes Using 17 Drugs.

    PubMed

    Kimoto, Emi; Bi, Yi-An; Kosa, Rachel E; Tremaine, Larry M; Varma, Manthena V S

    2017-09-01

    Hepatobiliary elimination can be a major clearance pathway dictating the pharmacokinetics of drugs. Here, we first compared the dose eliminated in bile in preclinical species (monkey, dog, and rat) with that in human and further evaluated single-species scaling (SSS) to predict human hepatobiliary clearance. Six compounds dosed in bile duct-cannulated (BDC) monkeys showed biliary excretion comparable to human; and the SSS of hepatobiliary clearance with plasma fraction unbound correction yielded reasonable predictions (within 3-fold). Although dog SSS also showed reasonable predictions, rat overpredicted hepatobiliary clearance for 13 of 24 compounds. Second, we evaluated the translatability of in vitro sandwich-cultured human hepatocytes (SCHHs) to predict human hepatobiliary clearance for 17 drugs. For drugs with no significant active uptake in SCHH studies (i.e., with or without rifamycin SV), measured intrinsic biliary clearance was directly scalable with good predictability (absolute average fold error [AAFE] = 1.6). Drugs showing significant active uptake in SCHH, however, showed improved predictability when scaled based on extended clearance term (AAFE = 2.0), which incorporated sinusoidal uptake along with a global scaling factor for active uptake and the canalicular efflux clearance. In conclusion, SCHH is a useful tool to predict human hepatobiliary clearance, whereas BDC monkey model may provide further confidence in the prospective predictions. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  8. A model of clearance rate regulation in mussels

    NASA Astrophysics Data System (ADS)

    Fréchette, Marcel

    2012-10-01

    Clearance rate regulation has been modelled as an instantaneous response to food availability, independent of the internal state of the animals. This view is incompatible with latent effects during ontogeny and phenotypic flexibility in clearance rate. Internal-state regulation of clearance rate is required to account for these patterns. Here I develop a model of internal-state based regulation of clearance rate. External factors such as suspended sediments are included in the model. To assess the relative merits of instantaneous regulation and internal-state regulation, I modelled blue mussel clearance rate and growth using a DEB model. In the usual standard feeding module, feeding is governed by a Holling's Type II response to food concentration. In the internal-state feeding module, gill ciliary activity and thus clearance rate are driven by internal reserve level. Factors such as suspended sediments were not included in the simulations. The two feeding modules were compared on the basis of their ability to capture the impact of latent effects, of environmental heterogeneity in food abundance and of physiological flexibility on clearance rate and individual growth. The Holling feeding module was unable to capture the effect of any of these sources of variability. In contrast, the internal-state feeding module did so without any modification or ad hoc calibration. Latent effects, however, appeared transient. With simple annual variability in temperature and food concentration, the relationship between clearance rate and food availability predicted by the internal-state feeding module was quite similar to that observed in Norwegian fjords. I conclude that in contrast with the usual Holling feeding module, internal-state regulation of clearance rate is consistent with well-documented growth and clearance rate patterns.

  9. Lung clearance index is a repeatable and sensitive indicator of radiological changes in bronchiectasis.

    PubMed

    Rowan, Stephen A; Bradley, Judy M; Bradbury, Ian; Lawson, John; Lynch, Tom; Gustafsson, Per; Horsley, Alex; O'Neill, Katherine; Ennis, Madeleine; Elborn, J Stuart

    2014-03-01

    In bronchiectasis there is a need for improved markers of lung function to determine disease severity and response to therapy. To assess whether the lung clearance index is a repeatable and more sensitive indicator of computed tomography (CT) scan abnormalities than spirometry in bronchiectasis. Thirty patients with stable bronchiectasis were recruited and lung clearance index, spirometry, and health-related quality of life measures were assessed on two occasions, 2 weeks apart when stable (study 1). A separate group of 60 patients with stable bronchiectasis was studied on a single visit with the same measurements and a CT scan (study 2). In study 1, the intervisit intraclass correlation coefficient for the lung clearance index was 0.94 (95% confidence interval, 0.89 to 0.97; P < 0.001). In study 2, the mean age was 62 (10) years, FEV1 76.5% predicted (18.9), lung clearance index 9.1 (2.0), and total CT score 14.1 (10.2)%. The lung clearance index was abnormal in 53 of 60 patients (88%) and FEV1 was abnormal in 37 of 60 patients (62%). FEV1 negatively correlated with the lung clearance index (r = -0.51, P < 0.0001). Across CT scores, there was a relationship with the lung clearance index, with little evidence of an effect of FEV1. There were no significant associations between the lung clearance index or FEV1 and health-related quality of life. The lung clearance index is repeatable and a more sensitive measure than FEV1 in the detection of abnormalities demonstrated on CT scan. The lung clearance index has the potential to be a useful clinical and research tool in patients with bronchiectasis.

  10. Inert gas clearance from tissue by co-currently and counter-currently arranged microvessels

    PubMed Central

    Lu, Y.; Michel, C. C.

    2012-01-01

    To elucidate the clearance of dissolved inert gas from tissues, we have developed numerical models of gas transport in a cylindrical block of tissue supplied by one or two capillaries. With two capillaries, attention is given to the effects of co-current and counter-current flow on tissue gas clearance. Clearance by counter-current flow is compared with clearance by a single capillary or by two co-currently arranged capillaries. Effects of the blood velocity, solubility, and diffusivity of the gas in the tissue are investigated using parameters with physiological values. It is found that under the conditions investigated, almost identical clearances are achieved by a single capillary as by a co-current pair when the total flow per tissue volume in each unit is the same (i.e., flow velocity in the single capillary is twice that in each co-current vessel). For both co-current and counter-current arrangements, approximate linear relations exist between the tissue gas clearance rate and tissue blood perfusion rate. However, the counter-current arrangement of capillaries results in less-efficient clearance of the inert gas from tissues. Furthermore, this difference in efficiency increases at higher blood flow rates. At a given blood flow, the simple conduction-capacitance model, which has been used to estimate tissue blood perfusion rate from inert gas clearance, underestimates gas clearance rates predicted by the numerical models for single vessel or for two vessels with co-current flow. This difference is accounted for in discussion, which also considers the choice of parameters and possible effects of microvascular architecture on the interpretation of tissue inert gas clearance. PMID:22604885

  11. Factors effective on peritoneal phosphorus transport and clearance in peritoneal dialysis patients
.

    PubMed

    Cebeci, Egemen; Gursu, Meltem; Uzun, Sami; Karadag, Serhat; Kazancioglu, Rumeyza; Ozturk, Savas

    2017-02-01

    Transport characteristics of phosphorus are different from other small solutes that are evaluated in routine peritoneal equilibration test (PET) in peritoneal dialysis (PD) patients. We aimed to evaluate peritoneal phosphorus clearance and permeability, and their relationship with peritoneal membrane transport type and creatinine clearance as well as factors affecting peritoneal phosphorus clearance. 70 adult patients on a PD program were included in our study. Phosphorus transport status was classified according to dialysate/plasma (D/P) phosphorus at the 4th hour of PET as slow transporter (< 0.47), slow-average transporter (0.47 - 0.56), fast-average transporter (0.57 - 0.67), and fast transporter (> 0.67). We evaluated the relationship of peritoneal phosphorus clearance and transport type with PD regime, phosphorus level, and presence of residual renal function in addition to investigating factors that are effective on peritoneal phosphorus clearance. D/P phosphorus and peritoneal phosphorus clearance were positively correlated with D/P creatinine and peritoneal creatinine clearance, respectively. Automated PD and continuous ambulatory PD patients were similar regarding phosphorus and creatinine clearances and transport status based on D/P phosphorus. The major determinant of peritoneal phosphorus clearance was anuria status. Anuric patients had higher dialysate volume (11.6 ± 3.0 L vs. 8.4 ± 2.1 L, p < 0.001) and therefore higher peritoneal phosphorus clearance (61.7 ± 15.1 L/week/1.73 m2 vs. 48.4 ± 14.0 L/week/1.73 m2, p = 0.001). Hyperphosphatemia was present in 40% and 11% of anuric patients and those with residual renal function, respectively (p = 0.005). Peritoneal phosphorus transport characteristics are similar to that of creatinine. Although increased dialysis dose may increase peritoneal phosphorus clearance, it may be insufficient to prevent hyperphosphatemia in anuric patients.
.

  12. Shape memory alloy adaptive control of gas turbine engine compressor blade tip clearance

    NASA Astrophysics Data System (ADS)

    Schetky, Lawrence M.; Steinetz, Bruce M.

    1998-06-01

    The ambient air ingested through the inlet of a gas turbine is first compressed by an axial compressor followed by further compression in a centrifugal compressor and then fed into the combustion chamber where ignition and expansion take place to produce the engine thrust. The axial compressor typically has five or more stages which consist of revolving blades and stators and the overall performance of the turbine is strongly affected by the compressor efficiency. When the turbine is turned on, to accommodate the rapid initial increase in the compressor blade length due to centrifugal force, the cold turbine has a built in clearance between the turbine blade tip and the casing. As the turbine reached its operating temperature there is a further increase in the blade length due to thermal expansion and, at the same time, the diameter of the casing increases. The net result is that when these various components have reached their equilibrium temperatures, the initial cold build clearance is reduced, but there remains a residual clearance. The magnitude of this clearance has a direct effect on the compressor efficiency and can be stated as: Δη/Δ CLR equals 0.5 where η is efficiency and CLR is the tip clearance. The concept of adaptive tip clearance control is based on the ability of a shape memory alloy ring to shrink to a predetermined diameter when heated to the temperature of a particular stage, and thus reducing the tip clearance. The ring is fabricated from a CuAlNi shape memory alloy and is mounted in the casing so as to be coaxial with the rotating blades of the particular stage. When cold, the ring dimensions are such as to provide the required cold build clearance, but when at operating temperature the reduced diameter creates a very small tip clearance. The clearance provided by this concept is much smaller than the clearance normally obtained for a turbine of the size being studied.

  13. Simple sampling strategy for measuring inulin renal clearance.

    PubMed

    Horio, Masaru; Imai, Enyu; Yasuda, Yoshinari; Hishida, Akira; Matsuo, Seiichi

    2009-02-01

    In the standard method of inulin clearance (Cin), three sets of serum and urine samples are collected during a 2-hour clearance period. For a practical use of this method, sampling should be the minimal number allowable while still providing enough accuracy. The aim of this study was to evaluate the validity of inulin renal clearance with assumed single urine collection with a period such as 30, 60 or 90 minutes. Inulin clearance data collected by the standard method from 737 individuals were used. Changes of serum inulin concentrations between 45 and 105 minutes after the start of the infusion were analyzed. We used first urine collection to calculate the inulin clearance with single urine collection (Cin-30 min). We assumed single urine collection for 60 or 90 minutes by combining the urine data of the consecutive 30-minute periods. Inulin clearances (Cin-60 min, Cin-90 min) were calculated from the assumed single urine collections, respectively. Serum inulin concentration did not reach equilibrium during the clearance period. It increased in subjects with low glomerular filtration rate (GFR) and decreased in subjects with normal GFR. The amount of the change was small and -0.5 +/- 12.6% in subjects with GFR over 30 ml/min per 1.73 m(2). Cin-30 min, Cin-60 min and Cin-90 min showed high correlation coefficients against Cin-ST (0.962, 0.988 and 0.998, respectively). Systemic biases in these clearances were negligible (under 1 ml/min per 1.73 m(2)). Root mean square error (RMSE) were 10.4, 5.3 and 2.3 ml/min per 1.73 m(2) for Cin-30 min, Cin-60 min and Cin-90 min, respectively. These data indicated that accuracy of inulin clearance depends on the duration of the urine collection period. Inulin clearance with a single urine collection is a convenient method. We showed that single urine collection for 30 minutes or a longer period has reasonable accuracy in calculation of inulin clearance. We propose a method of inulin clearance with single urine collection for 60 minutes.

  14. Augmented renal clearance in the ICU: results of a multicenter observational study of renal function in critically ill patients with normal plasma creatinine concentrations*.

    PubMed

    Udy, Andrew A; Baptista, João P; Lim, Noelle L; Joynt, Gavin M; Jarrett, Paul; Wockner, Leesa; Boots, Robert J; Lipman, Jeffrey

    2014-03-01

    To describe the prevalence and natural history of augmented renal clearance in a cohort of recently admitted critically ill patients with normal plasma creatinine concentrations. Multicenter, prospective, observational study. Four, tertiary-level, university-affiliated, ICUs in Australia, Singapore, Hong Kong, and Portugal. Study participants had to have an expected ICU length of stay more than 24 hours, no evidence of absolute renal impairment (admission plasma creatinine < 120 µmol/L), and no history of prior renal replacement therapy or chronic kidney disease. Convenience sampling was used at each participating site. Eight-hour urinary creatinine clearances were collected daily, as the primary method of measuring renal function. Augmented renal clearance was defined by a creatinine clearance more than or equal to 130 mL/min/1.73 m. Additional demographic, physiological, therapeutic, and outcome data were recorded prospectively. Nine hundred thirty-two patients were admitted to the participating ICUs over the study period, and 281 of which were recruited into the study, contributing 1,660 individual creatinine clearance measures. The mean age (95% CI) was 54.4 years (52.5-56.4 yr), Acute Physiology and Chronic Health Evaluation II score was 16 (15.2-16.7), and ICU mortality was 8.5%. Overall, 65.1% manifested augmented renal clearance on at least one occasion during the first seven study days; the majority (74%) of whom did so on more than or equal to 50% of their creatinine clearance measures. Using a mixed-effects model, the presence of augmented renal clearance on study day 1 strongly predicted (p = 0.019) sustained elevation of creatinine clearance in these patients over the first week in ICU. Augmented renal clearance appears to be a common finding in this patient group, with sustained elevation of creatinine clearance throughout the first week in ICU. Future studies should focus on the implications for accurate dosing of renally eliminated pharmaceuticals in patients with augmented renal clearance, in addition to the potential impact on individual clinical outcomes.

  15. Effects of Double-Leakage Tip Clearance Flow on the Performance of a Compressor Stage with a Large Rotor Tip Gap

    NASA Technical Reports Server (NTRS)

    Hah, Chunill

    2016-01-01

    Effects of a large rotor tip gap on the performance of a one and half stage axial compressor are investigated in detail with a numerical simulation based on LES and available PIV data. The current paper studies the main flow physics, including why and how the loss generation is increased with the large rotor tip gap. The present study reveals that when the tip gap becomes large, tip clearance fluid goes over the tip clearance core vortex and enters into the next blade's tip gap, which is called double-leakage tip clearance flow. As the tip clearance flow enters into the adjacent blade's tip gap, a vortex rope with a lower pressure core is generated. This vortex rope breaks up the tip clearance core vortex of the adjacent blade, resulting in a large additional mixing. This double-leakage tip clearance flow occurs at all operating conditions, from design flow to near stall condition, with the large tip gap for the current compressor stage. The double-leakage tip clearance flow, its interaction with the tip clearance core vortex of the adjacent blade, and the resulting large mixing loss are the main flow mechanism of the large rotor tip gap in the compressor. When the tip clearance is smaller, flow near the end wall follows more closely with the main passage flow and this double-leakage tip clearance flow does not happen near the design flow condition for the current compressor stage. When the compressor with a large tip gap operates at near stall operation, a strong vortex rope is generated near the leading edge due to the double-leakage flow. Part of this vortex separates from the path of the tip clearance core vortex and travels from the suction side of the blade toward the pressure side of the blade. This vortex is generated periodically at near stall operation with a large tip gap. As the vortex travels from the suction side to the pressure side of the blade, a large fluctuation of local pressure forces blade vibration. Nonsynchronous blade vibration occurs due to this vortex as the frequency of this vortex generation is not the same as the rotor. The present investigation confirms that this vortex is a part of separated tip clearance vortex, which is caused by the double-leakage tip clearance flow.

  16. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor surfaces, or between uninsulated conductor surfaces and grounded metal surfaces, within the enclosure shall...

  17. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor surfaces, or between uninsulated conductor surfaces and grounded metal surfaces, within the enclosure shall...

  18. 7 CFR 1927.53 - Costs of title clearance and closing of transactions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Costs of title clearance and closing of transactions... and Loan Closing § 1927.53 Costs of title clearance and closing of transactions. The borrower or the... payment of all costs of title clearance and closing of the transaction and will arrange for payment before...

  19. Not All Children with Cystic Fibrosis Have Abnormal Esophageal Neutralization during Chemical Clearance of Acid Reflux.

    PubMed

    Woodley, Frederick W; Moore-Clingenpeel, Melissa; Machado, Rodrigo Strehl; Nemastil, Christopher J; Jadcherla, Sudarshan R; Hayes, Don; Kopp, Benjamin T; Kaul, Ajay; Di Lorenzo, Carlo; Mousa, Hayat

    2017-09-01

    Acid neutralization during chemical clearance is significantly prolonged in children with cystic fibrosis, compared to symptomatic children without cystic fibrosis. The absence of available reference values impeded identification of abnormal findings within individual patients with and without cystic fibrosis. The present study aimed to test the hypothesis that significantly more children with cystic fibrosis have acid neutralization durations during chemical clearance that fall outside the physiological range. Published reference value for acid neutralization duration during chemical clearance (determined using combined impedance/pH monitoring) was used to assess esophageal acid neutralization efficiency during chemical clearance in 16 children with cystic fibrosis (3 to <18 years) and 16 age-matched children without cystic fibrosis. Duration of acid neutralization during chemical clearance exceeded the upper end of the physiological range in 9 of 16 (56.3%) children with and in 3 of 16 (18.8%) children without cystic fibrosis ( p =0.0412). The likelihood ratio for duration indicated that children with cystic fibrosis are 2.1-times more likely to have abnormal acid neutralization during chemical clearance, and children with abnormal acid neutralization during chemical clearance are 1.5-times more likely to have cystic fibrosis. Significantly more (but not all) children with cystic fibrosis have abnormally prolonged esophageal clearance of acid. Children with cystic fibrosis are more likely to have abnormal acid neutralization during chemical clearance. Additional studies involving larger sample sizes are needed to address the importance of genotype, esophageal motility, composition and volume of saliva, and gastric acidity on acid neutralization efficiency in cystic fibrosis children.

  20. Esophageal Acid Clearance During Random Swallowing Is Faster in Patients with Barrett’s Esophagus Than in Healthy Controls

    PubMed Central

    Lottrup, Christian; Krarup, Anne L; Gregersen, Hans; Ejstrud, Per; Drewes, Asbjørn M

    2016-01-01

    Background/Aims Impaired esophageal acid clearance may be a contributing factor in the pathogenesis of Barrett’s esophagus. However, few studies have measured acid clearance as such in these patients. In this explorative, cross-sectional study, we aimed to compare esophageal acid clearance and swallowing rate in patients with Barrett’s esophagus to that in healthy controls. Methods A total of 26 patients with histology-confirmed Barrett’s esophagus and 12 healthy controls underwent (1) upper endoscopy, (2) an acid clearance test using a pH-impedance probe under controlled conditions including controlled and random swallowing, and (3) an ambulatory pH-impedance measurement. Results Compared with controls and when swallowing randomly, patients cleared acid 46% faster (P = 0.008). Furthermore, patients swallowed 60% more frequently (mean swallows/minute: 1.90 ± 0.74 vs 1.19 ± 0.58; P = 0.005), and acid clearance time decreased with greater random swallowing rate (P < 0.001). Swallowing rate increased with lower distal esophageal baseline impedance (P = 0.014). Ambulatory acid exposure was greater in patients (P = 0.033), but clearance times assessed from the ambulatory pH-measurement and acid clearance test were not correlated (all P > 0.3). Conclusions More frequent swallowing and thus faster acid clearance in Barrett’s esophagus may constitute a protective reflex due to impaired mucosal integrity and possibly acid hypersensitivity. Despite these reinforced mechanisms, acid clearance ability seems to be overthrown by repeated, retrograde acid reflux, thus resulting in increased esophageal acid exposure and consequently mucosal changes. PMID:27557545

  1. Interstitial fluid drainage is impaired in ischemic stroke and Alzheimer’s disease mouse models

    PubMed Central

    Arbel-Ornath, Michal; Hudry, Eloise; Eikermann-Haerter, Katharina; Hou, Steven; Gregory, Julia L.; Zhao, Lingzhi; Betensky, Rebecca A.; Frosch, Matthew P.; Greenberg, Steven M.; Bacskai, Brian J.

    2013-01-01

    The interstitial fluid (ISF) drainage pathway has been hypothesized to underlie the clearance of solutes and metabolites from the brain. Previous work has implicated the perivascular spaces along arteries as the likely route for ISF clearance, however it has never been demonstrated directly. The accumulation of amyloid β (Aβ) peptides in brain parenchyma is one of the pathological hallmarks of Alzheimer disease (AD), and it is likely related to an imbalance between production and clearance of the peptide. Aβ drainage along perivascular spaces has been postulated to be one of the mechanisms that mediates the peptide clearance from the brain. We therefore devised a novel method to visualize solute clearance in real time in the living mouse brain using laser guided bolus dye injections and multiphoton imaging. This methodology allows high spatial and temporal resolution and revealed the kinetics of ISF clearance. We found that the ISF drains along perivascular spaces of arteries and capillaries but not veins, and its clearance exhibits a bi-exponential profile. ISF drainage requires a functional vasculature, as solute clearance decreased when perfusion was impaired. In addition, reduced solute clearance was observed in transgenic mice with significant vascular amyloid deposition; we suggest the existence of a feed-forward mechanism, by which amyloid deposition promotes further amyloid deposition. This important finding provides a mechanistic link between cerebrovascular disease and Alzheimer disease and suggests that facilitation of Aβ clearance along the perivascular pathway should be considered as a new target for therapeutic approaches to AD and CAA. PMID:23818064

  2. Allometric scaling for predicting human clearance of bisphenol A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collet, Séverine H., E-mail: s.collet@envt.fr; Picard-Hagen, Nicole, E-mail: n.hagen-picard@envt.fr; Lacroix, Marlène Z., E-mail: m.lacroix@envt.fr

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady statemore » volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.« less

  3. Delayed clearance of triglyceride‐rich lipoproteins in young, healthy obese subjects†

    PubMed Central

    Goll, R.; Lekahl, S.; Moen, O. S.; Florholmen, J.

    2015-01-01

    Summary Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age‐ and sex‐matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA‐IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA‐IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. PMID:26469529

  4. Pharmacoepidemiologic investigation of clonazepam relative clearance by mixed-effect modeling using routine clinical pharmacokinetic data in Japanese patients.

    PubMed

    Yukawa, Eiji; Satou, Masayasu; Nonaka, Toshiharu; Yukawa, Miho; Ohdo, Shigehiro; Higuchi, Shun; Kuroda, Takeshi; Goto, Yoshinobu

    2002-01-01

    The effects of drug-drug interactions on clonazepam clearance were examined through a retrospective analysis of serum concentration data from pediatric and adult epileptic patients. Patients received clonazepam as monotherapy or in combination with other antiepileptic drugs. A total of 259 serum clonazepam concentrations gathered from 137 patients were used in a population analysis of drug-drug interactions on clonazepam clearance. Data were analyzed using a nonlinear mixed-effects modeling (NONMEM) technique. The final model describing clonazepam clearance was CL = 152 x TBW(-0.181) x DIF, where CL is clearance (ml/kg/h), TBWis total body weight (kg), and DIF (drug interaction factor) is a scaling factor for concomitant medication with a value of 1 for patients on clonazepam monotherapy, 1.18 for those patients receiving concomitant administration of clonazepam and one antiepileptic drug (carbamazepine or valproic acid), and 2.12 x TBW(-0.119) for those patients receiving concomitant administration of clonazepam and more than two antiepileptic drugs. Clonazepam clearance decreased in a weight-related fashion in children, with minimal changes observed in adults. Concomitant administration of clonazepam and carbamazepine resulted in a 22% increase in clonazepam clearance. Concomitant administration of clonazepam and valproic acid resulted in a 12% increase in clonazepam clearance. Concomitant administration of clonazepam with two or more antiepileptic drugs resulted in a 23% to 75% increase in clonazepam clearance.

  5. Foot clearance and variability in mono- and multifocal intraocular lens users during stair navigation.

    PubMed

    Renz, Erik; Hackney, Madeleine; Hall, Courtney

    2016-01-01

    Intraocular lenses (IOLs) provide distance and near refraction and are becoming the standard for cataract surgery. Multifocal glasses increase variability of toe clearance in older adults navigating stairs and increase fall risk; however, little is known about the biomechanics of stair navigation in individuals with multifocal IOLs. This study compared clearance while ascending and descending stairs in individuals with monofocal versus multifocal IOLs. Eight participants with multifocal IOLs (4 men, 4 women; mean age = 66.5 yr, standard deviation [SD] = 6.26) and fifteen male participants with monofocal IOLs (mean age = 69.9 yr, SD = 6.9) underwent vision and mobility testing. Motion analysis recorded kinematic and custom software-calculated clearances in three-dimensional space. No significant differences were found between groups on minimum clearance or variability. Clearance differed for ascending versus descending stairs: the first step onto the stair had the greatest toe clearance during ascent, whereas the final step to the floor had the greatest heel clearance during descent. This preliminary study indicates that multifocal IOLs have similar biomechanic characteristics to monofocal IOLs. Given that step characteristics are related to fall risk, we can tentatively speculate that multifocal IOLs may carry no additional fall risk.

  6. Effect of clearance on cartilage tribology in hip hemi-arthroplasty.

    PubMed

    Lizhang, Jia; Taylor, Simon D; Jin, Zhongmin; Fisher, John; Williams, Sophie

    2013-12-01

    Hemi-arthroplasty of the hip (an artificial femoral head articulating against the natural acetabulum) is used to treat fractured necks of femur; however, there is evidence that articulation causes erosion of the cartilage, resulting in pain for the patient. Parameters that may influence this cartilage erosion include head material and roughness, clearance between the head and acetabulum and activity levels of the patient. This study has assessed the effect of clearance of hemi-arthroplasty articulations on the contact stress, friction and cartilage deformation in an in vitro tribological simulation of the hemi-arthroplasty joint that applied dynamic loads and motion. It has been demonstrated that peak contact stress increased from 5.6 to 10.6 MPa as radial clearance increased from small (<0.6 mm) to extra-large (>1.8 mm). In all samples, friction factor increased with time and was significantly less with extra-large clearances compared to small (<0.6 mm), medium (0.6-1.2 mm) and large (1.2-1.8 mm) clearances. The cartilage deformation observed was significantly greater in acetabulum samples paired to give small or extra-large clearances compared to those with medium or large clearances.

  7. Dynamic modelling and experimental study of cantilever beam with clearance

    NASA Astrophysics Data System (ADS)

    Li, B.; Jin, W.; Han, L.; He, Z.

    2012-05-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  8. Acute Effects of Walking Exercise on Stair Negotiation in Sedentary and Physically Active Older Adults.

    PubMed

    Kunzler, Marcos R; da Rocha, Emmanuel S; Bobbert, Maarten F; Duysens, Jacques; Carpes, Felipe P

    2017-07-01

    In negotiating stairs, low foot clearance increases the risk of tripping and a fall. Foot clearance may be related to physical fitness, which differs between active and sedentary participants, and be acutely affected by exercise. Impaired stair negotiation could be an acute response to exercise. Here we determined acute changes in foot clearances during stair walking in sedentary (n = 15) and physically active older adults (n = 15) after prolonged exercise. Kinematic data were acquired during negotiation with a 3-steps staircase while participants walked at preferred speed, before and after 30 min walking at preferred speed and using a treadmill. Foot clearances were compared before and after exercise and between the groups. Sedentary older adults presented larger (0.5 cm for lead and 2 cm for trail leg) toe clearances in ascent, smaller (0.7 cm) heel clearance in the leading foot in descent, and larger (1 cm) heel clearance in the trailing foot in descent than physically active. Sedentary older adults negotiate stairs in a slightly different way than active older adults, and 30 min walking at preferred speed does not affect clearance in stair negotiation.

  9. Rotor tip clearance effects on overall and blade-element performance of axial-flow transonic fan stage

    NASA Technical Reports Server (NTRS)

    Moore, R. D.

    1982-01-01

    The effects of tip clearance on the overall and blade-element performance of an axial-flow transonic fan stage are presented. The 50-centimeter-diameter fan was tested at four tip clearances (nonrotating) from 0.061 to 0.178 centimeter. The calculated radial growth of the blades was 0.040 centimeter at design conditions. The decrease in overall stage performance with increasing clearance is attributed to the loss in rotor performance. For the rotor the effects of clearance on performance parameters extended to about 70 percent of blade span from the tip. The stage still margin based on an assumed operating line decreased from 15.3 to 0 percent as the clearance increased from 0.061 to 0.178 centimeter.

  10. Methods and apparatus for controlling rotary machines

    DOEpatents

    Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Barnes, Gary R [Delanson, NY; Fric, Thomas Frank [Greer, SC; Lyons, James Patrick Francis [Niskayuna, NY; Pierce, Kirk Gee [Simpsonville, SC; Holley, William Edwin [Greer, SC; Barbu, Corneliu [Guilderland, NY

    2009-09-01

    A control system for a rotary machine is provided. The rotary machine has at least one rotating member and at least one substantially stationary member positioned such that a clearance gap is defined between a portion of the rotating member and a portion of the substantially stationary member. The control system includes at least one clearance gap dimension measurement apparatus and at least one clearance gap adjustment assembly. The adjustment assembly is coupled in electronic data communication with the measurement apparatus. The control system is configured to process a clearance gap dimension signal and modulate the clearance gap dimension.

  11. Modified Augmented Renal Clearance Score Predicts Rapid Piperacillin and Tazobactam Clearance in Critically Ill Surgery and Trauma Patients

    DTIC Science & Technology

    2014-04-24

    intermittent dosing regimens. CONCLUSION: Given its ability to predict antimicrobial clearance above populationmedians, which could compromise therapy, the...campaign dedicated to improve out- comes.1,2 In the era ofmultiply drug- resistant pathogens and rising antimicrobial minimum inhibitory concentrations (MICs...urinary creatinine clearance significantly exceeds what is predicted by the serum creatinine concentration according to various mathematical

  12. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  13. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  14. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  15. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  16. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  17. Effect of amiloride and saline on nasal mucociliary clearance and potential difference in cystic fibrosis and normal subjects.

    PubMed Central

    Middleton, P. G.; Geddes, D. M.; Alton, E. W.

    1993-01-01

    BACKGROUND--Mucociliary clearance is an important component of pulmonary defence. Maximum clearance is thought to depend on an optimal depth of the sol layer, allowing the most efficient interaction between the cilia and the overlying mucus layer. Sodium absorption, the major ion transport in human airways, is thought to be important in the regulation of the depth of the sol layer. In the airways of patients with cystic fibrosis sodium absorption is increased and mucociliary clearance decreased. Amiloride, a sodium channel blocker, has been shown to improve pulmonary mucociliary clearance in patients with cystic fibrosis. However, its effects on nasal mucociliary clearance in either normal subjects or those with cystic fibrosis are unknown. A study was therefore performed to investigate whether nebulised amiloride improves nasal mucociliary clearance in normal or cystic fibrosis subjects. METHODS--Nasal mucociliary clearance was measured by the saccharin clearance technique in 12 normal subjects and 12 with cystic fibrosis. For the control study measurements were made on two consecutive days and the mean time for each subject averaged. For the drug study measurements were also made on two consecutive days, after administration of nasally nebulised amiloride or placebo (saline) in a double blind manner. Nasal potential difference was measured in eight patients with cystic fibrosis after the administration of amiloride or placebo to assess the efficacy of deposition and duration of action. RESULTS--Baseline values of mucociliary clearance were significantly faster in the normal subjects than in those with cystic fibrosis. In both groups mucociliary clearance was increased after both saline and amiloride, with no significant difference between either treatment. As previously reported, baseline nasal potential difference was significantly more negative in the subjects with cystic fibrosis. Amiloride significantly reduced the potential difference for at least 60 minutes in these subjects. CONCLUSIONS--Nebulised saline significantly improves nasal mucociliary clearance in both normal subjects and those with cystic fibrosis. Amiloride did not appear to exert any additional effects in either group of subjects, despite evidence of its efficacy of deposition. PMID:8211871

  18. Pregnancy Increases the Renal Secretion of N1-methylnicotinamide, an Endogenous Probe for Renal Cation Transporters, in Patients Prescribed Metformin.

    PubMed

    Bergagnini-Kolev, Mackenzie C; Hebert, Mary F; Easterling, Thomas R; Lin, Yvonne S

    2017-03-01

    N 1 -methylnicotinamide (1-NMN) has been investigated as an endogenous probe for the renal transporter activity of organic cation transporter 2 (OCT2) and multidrug and toxin extrusion proteins 1 and 2-K (MATE1 and MATE2-K). As pregnancy increased the renal secretion of metformin, a substrate for OCT2, MATE1, and MATE2-K, we hypothesized that the renal secretion of 1-NMN would be similarly affected. Blood and urine samples collected from women prescribed metformin for type 2 diabetes, gestational diabetes, and polycystic ovarian syndrome during early, mid, and late pregnancy ( n = 34 visits) and postpartum ( n = 14 visits) were analyzed for 1-NMN using liquid chromatography-mass spectrometry. The renal clearance and secretion clearance, using creatinine clearance to correct for glomerular filtration, were estimated for 1-NMN and correlated with metformin renal clearance. 1-NMN renal clearance was higher in both mid (504 ± 293 ml/min, P < 0.01) and late pregnancy (557 ± 305 ml/min, P < 0.01) compared with postpartum (240 ± 106 ml/min). The renal secretion of 1-NMN was 3.5-fold higher in mid pregnancy (269± 267, P < 0.05) and 4.5-fold higher in late pregnancy compared with postpartum (342 ± 283 versus 76 ± 92 ml/min, P < 0.01). Because creatinine is also a substrate of OCT2, MATE1, and MATE2-K, creatinine clearance likely overestimates filtration clearance, whereas the calculated 1-NMN secretion clearance is likely underestimated. Metformin renal clearance and 1-NMN renal clearance were positively correlated (r s = 0.68, P < 0.0001). 1-NMN renal clearance increases during pregnancy due to increased glomerular filtration and net secretion by renal transporters. Copyright © 2017 by The American Society for Pharmacology and Experimental Therapeutics.

  19. Impact of impaired renal function on the pharmacokinetics of the antiepileptic drug lacosamide.

    PubMed

    Cawello, Willi; Fuhr, Uwe; Hering, Ursula; Maatouk, Haidar; Halabi, Atef

    2013-10-01

    The antiepileptic drug lacosamide is eliminated predominantly via the kidneys. Therefore, an evaluation of the impact of renal impairment on its pharmacokinetic profile is an important component of its safety assessment. The objective of this study was to evaluate the pharmacokinetic profile of lacosamide among individuals with renal impairment (mild, moderate, or severe) and among patients with end-stage renal disease (ESRD), including those on hemodialysis. This was an open-label, Phase I trial. The pharmacokinetics of a single oral 100-mg lacosamide dose were evaluated in five groups of participants: healthy controls, patients with mild, moderate, or severe renal impairment, and patients with ESRD (with and without hemodialysis). Forty participants completed the trial, eight in each group. In healthy volunteers, renal clearance accounted for approximately 30 % of total body clearance [geometric mean 0.5897 l/h (coefficient of variation 37.9 %) vs 2.13 l/h (20.8 %)]. With severe renal impairment, renal clearance was approximately 11 % of total body clearance [0.1428 l/h (31.8 %) vs 1.34 l/h (26.9 %)]. Terminal half-life and systemic exposure were increased with renal impairment, while total body clearance, renal clearance, and urinary excretion were decreased. Strong positive correlations between creatinine clearance, renal clearance, and urinary excretion were observed. Among patients with ESRD, approximately 50 % of lacosamide was cleared from systemic circulation by 4-h hemodialysis. In patients with essentially no renal clearance, nonrenal clearance was still present (1.1 l/h). Lacosamide was well tolerated by healthy volunteers and patients. In patients with mild-to-moderate renal impairment, lacosamide dose adjustment is not necessary, because total body clearance decreased by only approximately 20 %. Dose adjustment, however, is required for patients with severe renal impairment. Hemodialysis removes approximately 50 % of lacosamide from plasma; therefore, dose supplementation following hemodialysis should be considered.

  20. Dimerization of glycoprotein Ibα is not sufficient to induce platelet clearance.

    PubMed

    Liang, X; Syed, A K; Russell, S R; Ware, J; Li, R

    2016-02-01

    ESSENTIALS: Many anti-glycoprotein (GP)Ibα antibodies induce platelet clearance in a dimer-dependent manner. Characterization of monoclonal antibodies that bind the mechanosensitive domain (MSD) of GPIbα. An anti-MSD antibody binds two copies of GPIbα in platelets but does not induce platelet clearance. The prevailing clustering model of GPIbα signaling is incorrect or needs revision. The mechanism of platelet clearance is not clear. Many antibodies binding the membrane-distal ligand-binding domain of glycoprotein (GP)Ibα induce rapid clearance of platelets and acute thrombocytopenia, which requires the bifurcated antibody structure. It was thought that binding of these antibodies induced lateral dimerization or clustering of GPIbα in the plasma membrane, which leads to downstream signaling and platelet clearance. However, many antibodies targeting GPIbβ and GPIX, which are associated with GPIbα in the GPIb-IX complex, do not induce platelet clearance, which is in contradiction to the clustering model. To test whether dimerization or clustering of GPIbα is sufficient to transmit the signal that leads to platelet clearance. We have recently raised several mAbs targeting the mechanosensitive domain (MSD) of GPIbα. Binding of these anti-MSD antibodies was characterized with biochemical methods. Their ability to stimulate platelets and induce platelet clearance in mice was assessed. Infusion of anti-MSD antibodies does not cause thrombocytopenia in mice. These antibodies show no detectable effects on platelet activation and aggregation in vitro. Further biochemical investigation showed that the anti-MSD antibody 3D1 binds two copies of GPIbα on the platelet surface. Therefore, lateral dimerization of GPIbα induced by antibody binding is not sufficient to initiate GPIb-IX signaling and induce platelet clearance. Our results suggest that a factor other than or in addition to clustering of GPIbα is required to induce platelet clearance. © 2015 International Society on Thrombosis and Haemostasis.

  1. 76 FR 34761 - Classified National Security Information

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-14

    ... Commission is a micro agency of 14 full time permanent employees. Three employees have current Secret clearances and one staff has a Top Secret clearance. These employees require clearances because they attend...

  2. Reliability of ⁵¹Cr-EDTA plasma and urinary clearance as a measure of residual renal function in dialysis patients.

    PubMed

    Kjaergaard, Krista D; Jensen, Jens D; Jespersen, Bente; Rehling, Michael

    2011-12-01

    In dialysis patients, longer survival is associated with a higher residual renal function. Randomized controlled trials are conducted to clarify how residual renal function can be preserved. However, existing methods for measuring residual renal function are uncertain and there is a need for establishing a standard for measurements of glomerular filtration rate (GFR) in dialysis patients. ⁵¹Cr-EDTA clearances in plasma, urine, and dialysate were evaluated in a sample of 12 hemodialysis and 12 peritoneal dialysis patients. The patients' condition was generally stable, and all patients were investigated twice within 4-10 days. Plasma clearances of ⁵¹Cr-EDTA for all patients ranged between 2.1 and 30.8 mL/min/1.73 m², whereas urinary ⁵¹Cr-EDTA clearances ranged from 0.7-20.0 mL/min/1.73 m². This difference was statistically significant (p < 0.001). Week-to-week reproducibility expressed as coefficients of variation were below or equal to 10% for plasma clearances and 13% for urinary clearances in hemodialysis patients and 14% in peritoneal dialysis patients. This study demonstrated a difference between ⁵¹Cr-EDTA plasma and urinary clearances in dialysis patients. Plasma clearance of ⁵¹Cr-EDTA had the best reproducibility. For repeated measurements as in clinical prospective trials, we recommend ⁵¹Cr-EDTA plasma clearance based on blood sampling at 5 + 24 hours with subtraction of ⁵¹Cr-EDTA dialysate clearance in peritoneal dialysis patients. Further studies are needed to corroborate our findings.

  3. Selectively increasing the clearance of protein-bound uremic solutes

    PubMed Central

    Luo, Frank J.-G.; Plummer, Natalie S.; Hostetter, Thomas H.; Meyer, Timothy W.

    2012-01-01

    Background. The toxicity of bound solutes could be better evaluated if we could adjust the clearance of such solutes independent of unbound solutes. This study assessed whether bound solute clearances can be increased while maintaining urea clearance constant during the extended hours of nocturnal dialysis. Methods. Nine patients on thrice-weekly nocturnal dialysis underwent two experimental dialysis treatments 1 week apart. The experimental treatments were designed to provide the same urea clearance while providing widely different bound solute clearance. One treatment employed a large dialyzer and high dialyzate flow rate (Qd) of 800 mL/min while blood flow (Qb) was 270 mL/min. The other treatment employed a smaller dialyzer and Qd of 300 mL/min while Qb was 350 mL/min. Results. Treatment with the large dialyzer and higher Qd greatly increased the clearances of the bound solutes p-cresol sulfate (PCS: 27 ± 9 versus 14 ± 6 mL/min) and indoxyl sulfate (IS: 26 ± 8 versus 14 ± 5 mL/min) without altering the clearance of urea (204 ± 20 versus 193 ± 16 mL/min). Increasing PCS and IS clearances increased the removal of these solutes (PCS: 375 ± 200 versus 207 ± 86 mg/session; IS: 201 ± 137 versus 153 ± 74 mg/session), while urea removal was not different. Conclusions. The removal of bound solutes can thus be increased by raising the dialyzate flow and dialyzer size above the low levels sufficient to achieve target Kt/Vurea during extended treatment. Selectively increasing the clearance of bound solutes provides a potential means to test their toxicity. PMID:22231033

  4. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    PubMed Central

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 hours and then daily in 484 patients. AKI was defined either as > 50% increase in plasma creatinine from baseline, or > 33.3% decrease in creatinine clearance. The diagnostic and predictive performance of the two AKI definitions were compared. Results Creatinine clearance decrease diagnosed AKI in 24% of those not diagnosed by plasma creatinine increase on entry. These patients entered the ICU sooner after insult than those diagnosed with AKI by plasma creatinine elevation (P = 0.0041). Mortality and dialysis requirement increased with the change in creatinine clearance-acute kidney injury severity class (P = 0.0021). Amongst patients with plasma creatinine < 1.24 mg/dl on entry, creatinine clearance improved the prediction of AKI considerably (Net Reclassification Improvement 83%, Integrated Discrimination Improvement 0.29). On-entry, creatinine clearance associated with AKI severity and duration (P < 0.0001) predicted dialysis need (area under the curve: 0.75) and death (0.61). A > 33.3% decrease in creatinine clearance over the first 12 hours was associated with a 2.0-fold increased relative risk of dialysis or death. Conclusions Repeated 4-hour creatinine clearance measurements in critically ill patients allow earlier detection of AKI, as well as progression and recovery compared to plasma creatinine. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN012606000032550. PMID:22713519

  5. Increased dependence of leucine in posttraumatic sepsis: leucine/tyrosine clearance ratio as an indicator of hepatic impairment in septic multiple organ failure syndrome.

    PubMed

    Pittiruti, M; Siegel, J H; Sganga, G; Coleman, B; Wiles, C E; Belzberg, H; Wedel, S; Placko, R

    1985-09-01

    The body clearance of 10 plasma amino acids (AA) was determined from the rate of compared muscle-released AA and AA administered by infusion of total parenteral nutrition (TPN) compared to their estimated extracellular (ECW) pool in patients with multiple trauma with (n = 10) or without (n = 16) sepsis at 8-hour intervals. In both nonseptic and septic trauma, increasing TPN increased the mean clearance rate of all infused AA. When the individual AA clearance rates were normalized by the total AA infusion rate, regression-covariance analysis revealed that patients with sepsis had relatively impaired clearances of alanine (p less than 0.01) and methionine, proline, phenylalanine, and tyrosine p less than 0.05 for all). In contrast, the clearances of branched-chain AA (BCAA) valine and isoleucine were maintained, and the clearance of leucine was higher (p less than 0.05) in trauma patients with sepsis than in those without. At any AA infusion rate, compared with surviving patients with sepsis (p less than 0.05), patients who developed fatal multiple organ failure syndrome (MOFS) showed increased clearances of all BCAA with further impaired clearance of tyrosine. The clearance ratio of leucine/tyrosine was increased in MOFS at any AA infusion rate (p less than 0.0001), was an indicator of severity, and, if persistent, was a manifestation of a fatal outcome. Because tyrosine metabolism occurs almost entirely in the liver while leucine can be utilized by viscera and muscle, these data suggest early and progressive septic impairment of the pattern of hepatic uptake and oxidation of AA with a greater body dependence on BCAA, especially leucine, as septic MOFS develops.

  6. Single-sample 99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach.

    PubMed

    Gref, Margareta C; Karp, Kjell H

    2009-03-01

    The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.

  7. Wear in ceramic on ceramic type lumbar total disc replacement: effect of radial clearance.

    PubMed

    Shankar, S; Kesavan, D

    2015-01-01

    The wear of the bearing surfaces of total disc replacement (TDR) is a key problem leads to reduction in the lifetime of the prosthesis and it mainly occurs due to the range of clearances of the articulating surface between the superior plate and core. The objective of this paper is to estimate the wear using finite element concepts considering the different radial clearances between the articulating surfaces of ceramic on ceramic type Lumbar Total Disc Replacement (LTDR). The finite element (FE) model was subjected to wear testing protocols according to loading profile of International Standards Organization (ISO) 18192 standards through 10 million cycles. The radial clearance value of 0.05 mm showed less volumetric wear when compared with other radial clearance values. Hence, low radial clearance values are suitable for LTDR to minimize the wear.

  8. Sealing in Turbomachinery

    NASA Technical Reports Server (NTRS)

    Chupp, Raymond E.; Hendricks, Robert C.; Lattime, Scott B.; Steinetz, Bruce M.

    2006-01-01

    Clearance control is of paramount importance to turbomachinery designers and is required to meet today's aggressive power output, efficiency, and operational life goals. Excessive clearances lead to losses in cycle efficiency, flow instabilities, and hot gas ingestion into disk cavities. Insufficient clearances limit coolant flows and cause interface rubbing, overheating downstream components and damaging interfaces, thus limiting component life. Designers have put renewed attention on clearance control, as it is often the most cost effective method to enhance system performance. Advanced concepts and proper material selection continue to play important roles in maintaining interface clearances to enable the system to meet design goals. This work presents an overview of turbomachinery sealing to control clearances. Areas covered include: characteristics of gas and steam turbine sealing applications and environments, benefits of sealing, types of standard static and dynamics seals, advanced seal designs, as well as life and limitations issues.

  9. Novel sensors to enable closed-loop active clearance control in gas turbine engines

    NASA Astrophysics Data System (ADS)

    Geisheimer, Jonathan; Holst, Tom

    2014-06-01

    Active clearance control within the turbine section of gas turbine engines presents and opportunity within aerospace and industrial applications to improve operating efficiencies and the life of downstream components. Open loop clearance control is currently employed during the development of all new large core aerospace engines; however, the ability to measure the gap between the blades and the case and close down the clearance further presents as opportunity to gain even greater efficiencies. The turbine area is one of the harshest environments for long term placement of a sensor in addition to the extreme accuracy requirements required to enable closed loop clearance control. This paper gives an overview of the challenges of clearance measurements within the turbine as well as discusses the latest developments of a microwave sensor designed for this application.

  10. A Parametric Study of Actuator Requirements for Active Turbine Tip Clearance Control of a Modern High Bypass Turbofan Engine

    NASA Technical Reports Server (NTRS)

    Kratz, Jonathan L.; Chapman, Jeffryes W.; Guo, Ten-Huei

    2017-01-01

    The efficiency of aircraft gas turbine engines is sensitive to the distance between the tips of its turbine blades and its shroud, which serves as its containment structure. Maintaining tighter clearance between these components has been shown to increase turbine efficiency, increase fuel efficiency, and reduce the turbine inlet temperature, and this correlates to a longer time-on-wing for the engine. Therefore, there is a desire to maintain a tight clearance in the turbine, which requires fast response active clearance control. Fast response active tip clearance control will require an actuator to modify the physical or effective tip clearance in the turbine. This paper evaluates the requirements of a generic active turbine tip clearance actuator for a modern commercial aircraft engine using the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software that has previously been integrated with a dynamic tip clearance model. A parametric study was performed in an attempt to evaluate requirements for control actuators in terms of bandwidth, rate limits, saturation limits, and deadband. Constraints on the weight of the actuation system and some considerations as to the force which the actuator must be capable of exerting and maintaining are also investigated. From the results, the relevant range of the evaluated actuator parameters can be extracted. Some additional discussion is provided on the challenges posed by the tip clearance control problem and the implications for future small core aircraft engines.

  11. Automation for "Direct-to" Clearances in Air-Traffic Control

    NASA Technical Reports Server (NTRS)

    Erzberger, Heinz; McNally, David

    2006-01-01

    A method of automation, and a system of computer hardware and software to implement the method, have been invented to assist en-route air-traffic controllers in the issuance of clearances to fly directly to specified waypoints or navigation fixes along straight paths that deviate from previously filed flight plans. Such clearances, called "direct-to" clearances, have been in use since before the invention of this method and system.

  12. Estimation of end point foot clearance points from inertial sensor data.

    PubMed

    Santhiranayagam, Braveena K; Lai, Daniel T H; Begg, Rezaul K; Palaniswami, Marimuthu

    2011-01-01

    Foot clearance parameters provide useful insight into tripping risks during walking. This paper proposes a technique for the estimate of key foot clearance parameters using inertial sensor (accelerometers and gyroscopes) data. Fifteen features were extracted from raw inertial sensor measurements, and a regression model was used to estimate two key foot clearance parameters: First maximum vertical clearance (m x 1) after toe-off and the Minimum Toe Clearance (MTC) of the swing foot. Comparisons are made against measurements obtained using an optoelectronic motion capture system (Optotrak), at 4 different walking speeds. General Regression Neural Networks (GRNN) were used to estimate the desired parameters from the sensor features. Eight subjects foot clearance data were examined and a Leave-one-subject-out (LOSO) method was used to select the best model. The best average Root Mean Square Errors (RMSE) across all subjects obtained using all sensor features at the maximum speed for m x 1 was 5.32 mm and for MTC was 4.04 mm. Further application of a hill-climbing feature selection technique resulted in 0.54-21.93% improvement in RMSE and required fewer input features. The results demonstrated that using raw inertial sensor data with regression models and feature selection could accurately estimate key foot clearance parameters.

  13. Cleaning up the mess: cell corpse clearance in Caenorhabditis elegans.

    PubMed

    Pinto, Sérgio Morgado; Hengartner, Michael Otmar

    2012-12-01

    Genetic and cell biology studies have led to the identification in Caenorhabditis elegans of a set of evolutionary conserved cellular mechanisms responsible for the clearance of apoptotic cells. Based on the phenotype of cell corpse clearance mutants, corpse clearance can be divided into three distinct, but linked steps: corpse recognition, corpse internalization, and corpse degradation. Work in recent years has led to a better understanding of the molecular pathways that mediate each of these steps. Here, we review recent developments in our understanding of in vivo cell corpse clearance in this simple but most elegant model organism. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. CF6 Jet Engine Diagnostics Program: High pressure compressor clearance investigation

    NASA Technical Reports Server (NTRS)

    Radomski, M. A.

    1982-01-01

    The effects of high pressure compressor clearance changes on engine performance were experimentally determined on a CF6 core engine. The results indicate that a one percent reduction in normalized average clearance, expressed as a fraction of airfoil length, improves compressor efficiency by one percent. Compressor clearances are reduced by the application of rotor bore cooling, insulation of the stator casing, and use of a low coefficient of expansion material in the aft stages. This improvement amounts to a reduction of normalized average clearance of 0.78 percent, relative to CF6-60 compressor, which is equivalent to an improvement in compressor efficiency of 0.78 percent.

  15. Effect of increased surface hydrophobicity via drug conjugation on the clearance of inhaled PEGylated polylysine dendrimers.

    PubMed

    Haque, Shadabul; McLeod, Victoria M; Jones, Seth; Fung, Sandy; Whittaker, Michael; McIntosh, Michelle; Pouton, Colin; Owen, David J; Porter, Christopher J H; Kaminskas, Lisa M

    2017-10-01

    PEGylated polylysine dendrimers are attractive and well tolerated inhalable drug delivery platforms that have the potential to control the release, absorption kinetics and lung retention time of conjugated drugs. The clinical application of these systems though, would likely require partial substitution of surface PEG groups with drug molecules that are anticipated to alter their lung clearance kinetics and clearance pathways. In the current study, we therefore evaluated the impact of increased surface hydrophobicity via substitution of 50% surface PEG groups with a model hydrophobic drug (α-carboxyl OtButylated methotrexate) on the lung clearance of a Generation 5 PEGylated polylysine dendrimer in rats. PEG substitution with OtBu-methotrexate accelerated lung clearance of the dendrimer by increasing polylysine scaffold catabolism, improving systemic absorption of the intact dendrimer and low molecular weight products of scaffold catabolism, and enhancing mucociliary clearance. These results suggest that the conjugation of hydrophobic drug on the surface of a PEGylated dendrimer is likely to accelerate lung clearance when compared to a fully PEGylated dendrimer. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  16. Effect of Turbine Axial Nozzle-Wheel Clearance on Performance of Mark 25 Torpedo Power Plant

    NASA Technical Reports Server (NTRS)

    Hoyt, Jack W.; Kottas, Harry

    1948-01-01

    Investigations were made of the turbine from a Mark 25 torpedo to determine the performance of the unit with three different turbine nozzles at various axial nozzle-wheel clearances. Turbine efficiency with a reamed nondivergent nozzle that uses the axial clearance space for gas expansion was little affected by increasing the axial running clearance from 0.030 to 0.150 inch. Turbine efficiency with cast nozzles that expanded the gas inside the nozzle passage was found to be sensitive to increased axial nozzle-wheel clearance. A cast nozzle giving a turbine brake efficiency of 0.525 at an axial running clearance of 0.035 inch gave a brake efficiency of 0.475 when the clearance was increased to 0.095 inch for the same inlet-gas conditions and blade-jet speed ratio. If the basis for computing the isentropic power available to the turbine is the temperature inside the nozzle rather then the temperature in the inlet-gas pipe, an increase in turbine efficiency of about 0.01 is indicated.

  17. Calculation of tip clearance effects in a transonic compressor rotor

    NASA Technical Reports Server (NTRS)

    Chima, R. V.

    1996-01-01

    The flow through the tip clearance region of a transonic compressor rotor (NASA rotor 37) was computed and compared to aerodynamic probe and laser anemometer data. Tip clearance effects were modeled both by gridding the clearance gap and by using a simple periodicity model across the ungridded gap. The simple model was run with both the full gap height, and with half the gap height to simulate a vena-contracta effect. Comparisons between computed and measured performance maps and downstream profiles were used to validate the models and to assess the effects of gap height on the simple clearance model. Recommendations were made concerning the use of the simple clearance model. Detailed comparisons were made between the gridded clearance gap solution and the laser anemometer data near the tip at two operating points. The computer results agreed fairly well with the data but overpredicted the extent of the casing separation and underpredicted the wake decay rate. The computations were then used to describe the interaction of the tip vortex, the passage shock, and the casing boundary layer.

  18. 77 FR 14770 - Notice of Proposed Information Collection Requests

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-13

    ... Collection Clearance Division, Privacy, Information and Records Management Services, Office of Management... Collection Clearance Division, Privacy, Information and Records Management Services, Office of Management..., Acting Director, Information Collection Clearance Division, Privacy, Information and Records Management...

  19. Traffic incident management quick clearance laws : a national review of best practices.

    DOT National Transportation Integrated Search

    2008-12-01

    Constituting Quick Clearance Laws, three types of general legislation Move Over, Driver Removal, and Authority Removal laws - support concurrent Quick Clearance operations intended to enhance motorist and responder safety, as well as reduce...

  20. Regional Myocardial Blood Flow*

    PubMed Central

    Sullivan, Jay M.; Taylor, Warren J.; Elliott, William C.; Gorlin, Richard

    1967-01-01

    A method is described which measures the local effectiveness of the myocardial circulation, expressed as a clearance constant. Uniform clearance constants have been demonstrated in the normal canine and human myocardium. A distinct difference in clearance constants has been demonstrated between the normal canine myocardium and areas of naturally occurring disease. Heterogeneous clearance constants have been found in a majority of human subjects with coronary artery disease—the lowest rates being noted in areas of fibrous aneurysm. PMID:6036537

  1. Participation of the hypophyseal-adrenal cortex system in thrombin clearance during immobilization stress

    NASA Technical Reports Server (NTRS)

    Kudryashov, B. A.; Uljanov, A. M.; Shapiro, F. B.; Bazazyan, G. G.

    1981-01-01

    Thrombin marked with I-131 resulted in a considerable increase of the thrombined clearance rate in healthy male rats during stress caused by an immobilization lasting 30 minutes, and in an increase of thrombin clearance occurred by a combination of immobilization and administration of adrenocorticotropin (ACTH). Contrary to ACTH, the thrombin clearance is not stimulated in healthy animals by hydrocortisone. The results of the examination are presented.

  2. Measurement of Rotating Blade Tip Clearance with Fibre-Optic Probe

    NASA Astrophysics Data System (ADS)

    Cao, S. Z.; Duan, F. J.; Zhang, Y. G.

    2006-10-01

    This paper described a tip clearance measuring system with fibre-optic probe. The system is based on a novel tip clearance sensor of optical fibre-bundle mounted on the casing, rotating speed synchronization sensor mounted on the rotating shaft, the tip clearance preamplification processing circuit followed by high speed data-acquisition unit. A novel tip clearance sensor of trifurcated optical fibre bundle was proposed and demonstrated. It is independent of material of measured surface but capacitive probe demands target conductive. Measurements can be taken under severe conditions such as ionization. Sensor circuitry and data acquisition circuit were successfully designed. With the help of Rotation synchronized sensor, all the blades can be detected in real-time. Because of fibre-optic sensor, the measuring system has commendably frequency response, which can work well in high rotating speed from 0-15000rpm.The measurement range of tip clearance is 0-3mm with 25um precision.

  3. Physiological stability and renal clearance of ultrasmall zwitterionic gold nanoparticles: Ligand length matters

    NASA Astrophysics Data System (ADS)

    Ning, Xuhui; Peng, Chuanqi; Li, Eric S.; Xu, Jing; Vinluan, Rodrigo D.; Yu, Mengxiao; Zheng, Jie

    2017-05-01

    Efficient renal clearance has been observed from ultrasmall zwitterionic glutathione-coated gold nanoparticles (GS-AuNPs), which have broad preclinical applications in cancer diagnosis and kidney functional imaging. However, origin of such efficient renal clearance is still not clear. Herein, we conducted head-to-head comparison on physiological stability and renal clearance of two zwitterionic luminescent AuNPs coated with cysteine and glycine-cysteine (Cys-AuNPs and Gly-Cys-AuNPs), respectively. While both of them exhibited similar surface charges and the same core sizes, additional glycine slightly increased the hydrodynamic diameter of the AuNPs by 0.4 nm but significantly enhanced physiological stability of the AuNPs as well as altered their clearance pathways. These studies indicate that the ligand length, in addition to surface charges and size, also plays a key role in the physiological stability and renal clearance of ultrasmall zwitterionic inorganic NPs.

  4. Indocyanine green. Its use as an early indicator of hepatic dysfunction following injury in man.

    PubMed

    Gottlieb, M E; Stratton, H H; Newell, J C; Shah, D M

    1984-03-01

    To evaluate hepatic function, the kinetics of indocyanine green clearance were studied in seven injured patients with hepatic venous catheters. Indocyanine green clearance after a bolus injection of 20 mg was relatively monoexponential on the first day after injury. Following this, a second slower compartment of indocyanine green clearance was uniformly evident, becoming most prominent around the fourth day after injury. Indocyanine green clearance again became more uniform as recovery continued. Fractional indocyanine green extraction ten minutes after injection decreased from 0.9 on the first day after injury to 0.2 three days later, and then returned to 0.7 on the seventh day after injury. These decreases in indocyanine green clearance preceded an increase in total serum bilirubin concentration to a mean value of 1.9 mg/dL. Indocyanine green clearance was thus found to be an early and sensitive indicator of impaired hepatic function.

  5. Comparing taxi clearance input layouts for advancements in flight deck automation for surface operations

    NASA Astrophysics Data System (ADS)

    Cheng, Lara W. S.

    Airport moving maps (AMMs) have been shown to decrease navigation errors, increase taxiing speed, and reduce workload when they depict airport layout, current aircraft position, and the cleared taxi route. However, current technologies are limited in their ability to depict the cleared taxi route due to the unavailability of datacomm or other means of electronically transmitting clearances from ATC to the flight deck. This study examined methods by which pilots can input ATC-issued taxi clearances to support taxi route depictions on the AMM. Sixteen general aviation (GA) pilots used a touchscreen monitor to input taxi clearances using two input layouts, softkeys and QWERTY, each with and without feedforward (graying out invalid inputs). QWERTY yielded more taxi route input errors than the softkeys layout. The presence of feedforward did not produce fewer taxi route input errors than in the non-feedforward condition. The QWERTY layout did reduce taxi clearance input times relative to the softkeys layout, but when feedforward was present this effect was observed only for the longer, 6-segment taxi clearances. It was observed that with the softkeys layout, feedforward reduced input times compared to non-feedforward but only for the 4-segment clearances. Feedforward did not support faster taxi clearance input times for the QWERTY layout. Based on the results and analyses of the present study, it is concluded that for taxi clearance inputs, (1) QWERTY remain the standard for alphanumeric inputs, and (2) feedforward be investigated further, with a focus on participant preference and performance of black-gray contrast of keys.

  6. Non-invasive Imaging of Sendai Virus Infection in Pharmacologically Immunocompromised Mice: NK and T Cells, but not Neutrophils, Promote Viral Clearance after Therapy with Cyclophosphamide and Dexamethasone

    PubMed Central

    Mostafa, Heba H.; Vogel, Peter; Srinivasan, Ashok; Russell, Charles J.

    2016-01-01

    In immunocompromised patients, parainfluenza virus (PIV) infections have an increased potential to spread to the lower respiratory tract (LRT), resulting in increased morbidity and mortality. Understanding the immunologic defects that facilitate viral spread to the LRT will help in developing better management protocols. In this study, we immunosuppressed mice with dexamethasone and/or cyclophosphamide then monitored the spread of viral infection into the LRT by using a noninvasive bioluminescence imaging system and a reporter Sendai virus (murine PIV type 1). Our results show that immunosuppression led to delayed viral clearance and increased viral loads in the lungs. After cessation of cyclophosphamide treatment, viral clearance occurred before the generation of Sendai-specific antibody responses and coincided with rebounds in neutrophils, T lymphocytes, and natural killer (NK) cells. Neutrophil suppression using anti-Ly6G antibody had no effect on infection clearance, NK-cell suppression using anti-NK antibody delayed clearance, and T-cell suppression using anti-CD3 antibody resulted in no clearance (chronic infection). Therapeutic use of hematopoietic growth factors G-CSF and GM-CSF had no effect on clearance of infection. In contrast, treatment with Sendai virus—specific polysera or a monoclonal antibody limited viral spread into the lungs and accelerated clearance. Overall, noninvasive bioluminescence was shown to be a useful tool to study respiratory viral progression, revealing roles for NK and T cells, but not neutrophils, in Sendai virus clearance after treatment with dexamethasone and cyclophosphamide. Virus-specific antibodies appear to have therapeutic potential. PMID:27589232

  7. Effect of neurotrauma on hepatic drug clearance.

    PubMed

    Boucher, B A; Kuhl, D A; Fabian, T C; Robertson, J T

    1991-11-01

    Lorazepam, antipyrine, and indocyanine green were administered to 10 patients with severe head injuries as marker substrates of hepatic glucuronidation, oxidation, and hepatic blood flow, respectively. Pharmacokinetic parameter estimates were determined at baseline (20 to 80 hours after injury) and up to three additional times thereafter (study days 4, 7, and 14). Antipyrine clearance was increased significantly from baseline (0.50 +/- 0.31 ml/min/kg) on study days 4, 7, and 14 (p less than 0.0001). Increases in antipyrine clearance from baseline to the last study day were observed in all study patients ranging from 14% to 207%. A significant increase was also observed in lorazepam clearance on study day 14 relative to baseline (1.39 +/- 0.56 ml/min/kg) (p less than 0.005). Increases in lorazepam clearance occurred in seven of nine patients over time ranging from 9% to 130%. The unbound fraction of lorazepam did not change significantly over the study period. Likewise, no significant change was observed in the clearance of indocyanine green over time. Antipyrine clearance and alpha 1-acid glycoprotein (r = 0.41), and lorazepam clearance and C-reactive protein (r = -0.38) were significantly correlated (p less than 0.05). Similarly, antipyrine and lorazepam clearances were significantly correlated with injury severity based on the Acute Physiologic and Chronic Health Evaluation (APACHE II) score (r = -0.43 and r = -0.37, respectively). These findings suggest that hepatic oxidative and conjugative metabolism increase significantly over time in patients after acute head injury. An awareness of the potential for pharmacokinetic alterations in similarly metabolized drugs used for patients with severe head injuries is recommended.

  8. Predicting Human Clearance of OATP substrates using Cynomolgus monkey: In vitro-in vivo scaling of hepatic uptake clearance.

    PubMed

    de Bruyn, Tom; Ufuk, Ayse; Cantrill, Carina; Kosa, Rachel E; Bi, Yi-An; Niosi, Mark; Modi, Sweta; Rodrigues, A David; Tremaine, Larry M; Varma, Manthena Vs; Galetin, Aleksandra; Houston, J Brian

    2018-05-02

    This work explores the utility of the cynomolgus monkey as a preclinical model to predict hepatic uptake clearance mediated by organic anion transporting polypeptide (OATP) transporters. Nine OATP substrates (rosuvastatin, pravastatin, repaglinide, fexofenadine, cerivastatin, telmisartan, pitavastatin, bosentan and valsartan) were investigated in plated cynomolgus monkey and human hepatocytes. Total uptake clearance and passive diffusion were measured in vitro from initial rates in the absence and presence of the OATP inhibitor rifamycin SV, respectively. Total uptake clearance values in plated hepatocytes ranged over three orders of magnitude in both species with a similar rank order and good agreement in the relative contribution of active transport to total uptake between cynomolgus monkey and human. In vivo hepatic clearance for these nine drugs was determined in cynomolgus monkey after intravenous dosing. Hepatic clearances showed a similar range to human parameters and good predictions from respective hepatocyte parameters (with 2.7 and 3.8-fold bias on average, respectively). The use of cross species empirical scaling factors (based on either dataset average or individual drug scaling factor from cynomolgus monkey data) improved prediction (less bias, better concordance) of human hepatic clearance from human hepatocyte data alone. In vitro intracellular binding in hepatocytes also correlated well between species. It is concluded that the minimal species differences observed for the current dataset between cynomolgus monkey and human hepatocyte uptake, both in vitro and in vivo, support future use of this preclinical model to delineate drug hepatic uptake and enable prediction of human in vivo intrinsic hepatic clearance. The American Society for Pharmacology and Experimental Therapeutics.

  9. Confusion in Using Pre-Departure Clearances

    DOT National Transportation Integrated Search

    1996-12-20

    In 1990, the FAA implemented the Pre-Departure Clearance (PDC) program at a : number of U.S. airports. This system allows pilots to obtain IFR clearances : through aircraft ACARS units prior to taxi-out, thus eliminating the need for : verbal communi...

  10. [Correlation index amylase-creatinine clearance to endogenous creatinine clearance in severe preeclampsia].

    PubMed

    Vázquez Rodríguez, Juan Gustavo; Cruz Cruz, Polita del Rocío; Márquez Hubert, Elizabeth

    2009-07-01

    Tubular lesion may cause acute renal insufficiency in pregnant patients with severe preeclampsia. To describe the correlation between the amylase/creatinine clearance ratio and endogenous creatinine depuration in pregnant patients with severe preeclampsia. Transversal study (pilot study) twenty eight women with pregnancies of 20 to 40 weeks complicated by severe preeclampsia were studied. Subjects had serum and urine creatinine and amylase determinations to calculate the amylase/creatinine clearance ratio (%). According to the results, two groups were formed: group A (> 3%) and group B (< or = 3%). The correlation between amylase/creatinine clearance ratio and endogenous creatinine depuration was evaluated. measures of central tendency and dispersion, Student's t-test, Pearson correlation coefficient (r) and linear regression were used. Group A included 23 cases (82%) and group B included 5 cases (18%). Amylase/creatinine clearance ratio (%) for group A was 5.22 +/- 1.6 and for group B was 2.41 +/- 0.41 (p = 0.001). The endogenous creatinine depuration (mL /min. /1.73 m2 SC) for group A was 105.6 +/- 9.71 and for group B was 132.10 +/- 7.95 (p = 0.54). The r between amylase/creatinine clearance ratio and endogenous creatinine depuration for group A was -0.43 and for group B was -0.25. A moderately significant negative correlation exists between amylase/creatinine clearance ratio and endogenous creatinine depuration.

  11. Dynamic clearance measure to evaluate locomotor and perceptuo-motor strategies used for obstacle circumvention in a virtual environment.

    PubMed

    Darekar, Anuja; Lamontagne, Anouk; Fung, Joyce

    2015-04-01

    Circumvention around an obstacle entails a dynamic interaction with the obstacle to maintain a safe clearance. We used a novel mathematical interpolation method based on the modified Shepard's method of Inverse Distance Weighting to compute dynamic clearance that reflected this interaction as well as minimal clearance. This proof-of-principle study included seven young healthy, four post-stroke and four healthy age-matched individuals. A virtual environment designed to assess obstacle circumvention was used to administer a locomotor (walking) and a perceptuo-motor (navigation with a joystick) task. In both tasks, participants were asked to navigate towards a target while avoiding collision with a moving obstacle that approached from either head-on, or 30° left or right. Among young individuals, dynamic clearance did not differ significantly between obstacle approach directions in both tasks. Post-stroke individuals maintained larger and smaller dynamic clearance during the locomotor and the perceptuo-motor task respectively as compared to age-matched controls. Dynamic clearance was larger than minimal distance from the obstacle irrespective of the group, task and obstacle approach direction. Also, in contrast to minimal distance, dynamic clearance can respond differently to different avoidance behaviors. Such a measure can be beneficial in contrasting obstacle avoidance behaviors in different populations with mobility problems. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Dynamic alteration in splenic function during acute falciparum malaria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Looareesuwan, S.; Ho, M.; Wattanagoon, Y.

    Plasmodium-infected erythrocytes lose their normal deformability and become susceptible to splenic filtration. In animal models, this is one mechanism of antimalarial defense. To assess the effect of acute falciparum malaria on splenic filtration, we measured the clearance of heated /sup 51/Cr-labeled autologous erythrocytes in 25 patients with acute falciparum malaria and in 10 uninfected controls. Two groups of patients could be distinguished. Sixteen patients had splenomegaly, markedly accelerated clearance of the labeled erythrocytes (clearance half-time, 8.4 +/- 4.4 minutes (mean +/- SD) vs. 62.5 +/- 36.5 minutes in controls; P less than 0.001), and a lower mean hematocrit than didmore » the patients without splenomegaly (P less than 0.001). In the nine patients without splenomegaly, clearance was normal. After institution of antimalarial chemotherapy, however, the clearance in this group accelerated to supernormal rates similar to those in the patients with splenomegaly, but without the development of detectable splenomegaly. Clearance was not significantly altered by treatment in the group with splenomegaly. Six weeks later, normal clearance rates were reestablished in most patients in both groups. We conclude that splenic clearance of labeled erythrocytes is enhanced in patients with malaria if splenomegaly is present and is enhanced only after treatment if splenomegaly is absent. Whether this enhanced splenic function applies to parasite-infected erythrocytes in patients with malaria and has any clinical benefit will require further studies.« less

  13. Secretion clearance strategies in Australian and New Zealand Intensive Care Units.

    PubMed

    Ntoumenopoulos, George; Hammond, Naomi; Watts, Nicola R; Thompson, Kelly; Hanlon, Gabrielle; Paratz, Jennifer D; Thomas, Peter

    2017-06-26

    To describe the processes of care for secretion clearance in adult, intubated and mechanically ventilated patients in Australian and New Zealand Intensive Care Units (ICUs). A prospective, cross-sectional study was conducted through the Australian and New Zealand Intensive Care Society Clinical Trials Group (ANZICS CTG) Point Prevalence Program. Forty-seven ICUs collected data from 230 patients intubated and ventilated on the study day. Secretion clearance techniques beyond standard suctioning were used in 84/230 (37%) of patients during the study period. Chest wall vibration 34/84 (40%), manual lung hyperinflation 24/84 (29%), chest wall percussion 20/84 (24%), postural drainage/patient positioning 17/84 (20%) and other techniques including mobilisation 15/84 (18%), were the most common secretion clearance techniques employed. On average (SD), patients received airway suctioning 8.8 (5.0) times during the 24-h study period. Mucus plugging events were infrequent (2.7%). The additional secretion clearance techniques were provided by physiotherapy staff in 24/47 (51%) ICUs and by both nursing and physiotherapy staff in the remaining 23/47 (49%) ICUs. One-third of intubated and ventilated patients received additional secretion clearance techniques. Mucus plugging events were infrequent with these additional secretion clearance approaches. Prospective studies must examine additional secretion clearance practices, prevalence of mucus plugging episodes and impact on patient outcomes. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  14. Differences in amyloid-β clearance across mouse and human blood-brain barrier models: kinetic analysis and mechanistic modeling.

    PubMed

    Qosa, Hisham; Abuasal, Bilal S; Romero, Ignacio A; Weksler, Babette; Couraud, Pierre-Oliver; Keller, Jeffrey N; Kaddoumi, Amal

    2014-04-01

    Alzheimer's disease (AD) has a characteristic hallmark of amyloid-β (Aβ) accumulation in the brain. This accumulation of Aβ has been related to its faulty cerebral clearance. Indeed, preclinical studies that used mice to investigate Aβ clearance showed that efflux across blood-brain barrier (BBB) and brain degradation mediate efficient Aβ clearance. However, the contribution of each process to Aβ clearance remains unclear. Moreover, it is still uncertain how species differences between mouse and human could affect Aβ clearance. Here, a modified form of the brain efflux index method was used to estimate the contribution of BBB and brain degradation to Aβ clearance from the brain of wild type mice. We estimated that 62% of intracerebrally injected (125)I-Aβ40 is cleared across BBB while 38% is cleared by brain degradation. Furthermore, in vitro and in silico studies were performed to compare Aβ clearance between mouse and human BBB models. Kinetic studies for Aβ40 disposition in bEnd3 and hCMEC/D3 cells, representative in vitro mouse and human BBB models, respectively, demonstrated 30-fold higher rate of (125)I-Aβ40 uptake and 15-fold higher rate of degradation by bEnd3 compared to hCMEC/D3 cells. Expression studies showed both cells to express different levels of P-glycoprotein and RAGE, while LRP1 levels were comparable. Finally, we established a mechanistic model, which could successfully predict cellular levels of (125)I-Aβ40 and the rate of each process. Established mechanistic model suggested significantly higher rates of Aβ uptake and degradation in bEnd3 cells as rationale for the observed differences in (125)I-Aβ40 disposition between mouse and human BBB models. In conclusion, current study demonstrates the important role of BBB in the clearance of Aβ from the brain. Moreover, it provides insight into the differences between mouse and human BBB with regards to Aβ clearance and offer, for the first time, a mathematical model that describes Aβ clearance across BBB. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Differences in amyloid-β clearance across mouse and human blood-brain barrier models: Kinetic analysis and mechanistic modeling

    PubMed Central

    Qosa, Hisham; Abuasal, Bilal S.; Romero, Ignacio A.; Weksler, Babette; Couraud, Pierre-Oliver; Keller, Jeffrey N.; Kaddoumi, Amal

    2014-01-01

    Alzheimer’s disease (AD) has a characteristic hallmark of amyloid-β (Aβ) accumulation in the brain. This accumulation of Aβ has been related to its faulty cerebral clearance. Indeed, preclinical studies that used mice to investigate Aβ clearance showed that efflux across blood-brain barrier (BBB) and brain degradation mediate efficient Aβ clearance. However, the contribution of each process to Aβ clearance remains unclear. Moreover, it is still uncertain how species differences between mouse and human could affect Aβ clearance. Here, a modified form of the brain efflux index method was used to estimate the contribution of BBB and brain degradation to Aβ clearance from the brain of wild type mice. We estimated that 62% of intracerebrally injected 125I-Aβ40 is cleared across BBB while 38% is cleared by brain degradation. Furthermore, in vitro and in silico studies were performed to compare Aβ clearance between mouse and human BBB models. Kinetic studies for Aβ40 disposition in bEnd3 and hCMEC/D3 cells, representative in vitro mouse and human BBB models, respectively, demonstrated 30-fold higher rate of 125I-Aβ40 uptake and 15-fold higher rate of degradation by bEnd3 compared to hCMEC/D3 cells. Expression studies showed both cells to express different levels of P-glycoprotein and RAGE, while LRP1 levels were comparable. Finally, we established a mechanistic model, which could successfully predict cellular levels of 125I-Aβ40 and the rate of each process. Established mechanistic model suggested significantly higher rates of Aβ uptake and degradation in bEnd3 cells as rationale for the observed differences in 125I-Aβ40 disposition between mouse and human BBB models. In conclusion, current study demonstrates the important role of BBB in the clearance of Aβ from the brain. Moreover, it provides insight into the differences between mouse and human BBB with regards to Aβ clearance and offer, for the first time, a mathematical model that describes Aβ clearance across BBB. PMID:24467845

  16. Axial compressor blade design for desensitization of aerodynamic performance and stability to tip clearance

    NASA Astrophysics Data System (ADS)

    Erler, Engin

    Tip clearance flow is the flow through the clearance between the rotor blade tip and the shroud of a turbomachine, such as compressors and turbines. This flow is driven by the pressure difference across the blade (aerodynamic loading) in the tip region and is a major source of loss in performance and aerodynamic stability in axial compressors of modern aircraft engines. An increase in tip clearance, either temporary due to differential radial expansion between the blade and the shroud during transient operation or permanent due to engine wear or manufacturing tolerances on small blades, increases tip clearance flow and results in higher fuel consumption and higher risk of engine surge. A compressor design that can reduce the sensitivity of its performance and aerodynamic stability to tip clearance increase would have a major impact on short and long-term engine performance and operating envelope. While much research has been carried out on improving nominal compressor performance, little had been done on desensitization to tip clearance increase beyond isolated observations that certain blade designs such as forward chordwise sweep, seem to be less sensitive to tip clearance size increase. The current project aims to identify through a computational study the flow features and associated mechanisms that reduces sensitivity of axial compressor rotors to tip clearance size and propose blade design strategies that can exploit these results. The methodology starts with the design of a reference conventional axial compressor rotor followed by a parametric study with variations of this reference design through modification of the camber line and of the stacking line of blade profiles along the span. It is noted that a simple desensitization method would be to reduce the aerodynamic loading of the blade tip which would reduce the tip clearance flow and its proportional contribution to performance loss. However, with the larger part of the work on the flow done in this region, this approach would entail a nominal performance penalty. Therefore, the chosen rotor design philosophy aims to keep the spanwise loading constant to avoid trading performance for desensitization. The rotor designs that resulted from this exercise are simulated in ANSYS CFX at different tip clearance sizes. The change in their performance with respect to tip clearance size (sensitivity) is compared both on an integral level in terms of pressure ratio and adiabatic efficiency, as well as on a detailed level in terms of aerodynamic losses and blockage associated with tip clearance flow. The sensitivity of aerodynamic stability is evaluated either directly through the simulations of the rotor characteristics up to the stall point (expensive in time and resources) for a few designs or indirectly through the position of the interface between the incoming and tip clearance flow with respect to the rotor leading edge plane. The latter approach is based on a generally observed stall criteria in modern axial compressors. The rotor designs are then assessed according to their sensitivity in comparison to that of the reference rotor design to detect features that can explain the trend in sensitivity to tip clearance size. These features can then be validated and the associated flow mechanisms explained through numerical simulations and modelling. Analysis of the database from the rotor parametric study shows that the observed trend in sensitivity cannot be explained by the shifting of the aerodynamic loading along the blade chord, as initially hypothesized based on the literature review. Instead, two flow features are found to reduce sensitivity of performance and stability to tip clearance, namely an increase in incoming meridional momentum in the tip region and a reduction/elimination of double leakage flow. Double leakage flow is the flow that exits the tip clearance of one blade and proceeds into the clearance of the adjacent blade rather than convecting downstream out of the local blade passage. These flow features are isolated and validated based on the reference rotor design through changes in the inlet total pressure condition to alter incoming flow momentum and blade number count to change double leakage rate. In terms of flow mechanism, double leakage is shown to be detrimental to performance and stability, and its proportional increase with tip clearance size explains the sensitivity increase in the presence of double leakage and, conversely, the desensitization effect of reducing or eliminating double leakage. The increase in incoming meridional momentum in the tip region reduces sensitivity to tip clearance through its reduction of double leakage as well as through improved mixing with tip clearance flow, as demonstrated by an analytical model without double leakage flow. The above results imply that any blade design strategy that exploits the two desensitizing flow features would reduce the performance and stability sensitivity to tip clearance size. The increase of the incoming meridional momentum can be achieved through forward chordwise sweep of the blade. The reduction of double leakage without changing blade pitch can be obtained by decreasing the blade stagger angle in the tip region. Examples of blade designs associated with these strategies are shown through CFX simulations to be successful in reducing sensitivity to tip clearance size.

  17. AHERA CLEARANCE AT TWENTY ABATEMENT SITES

    EPA Science Inventory

    A study was conducted during the summer of 1988 to document Asbestos Hazard Emergency Response Act (AHERA) clearance air-sampling practices and clearance concentrations of airborne asbestos at 20 asbestos-abatement sites in New Jersey. Each abatement took place in a school buildi...

  18. AHERA CLEARANCE AT TWENTY ABATEMENT SITES

    EPA Science Inventory

    A study was conducted during the summer of 1988 to document Asbestos Hazard Emergency Response Act (AHERA) clearance air sampling practices and clearance concentrations of airborne asbestos at 20 asbestos-abatement sites in New Jersey. ach abatement took place in a school buildin...

  19. The effects of topical agents of fluticasone propionate, oxymetazoline, and 3% and 0.9% sodium chloride solutions on mucociliary clearance in the therapy of acute bacterial rhinosinusitis in vivo.

    PubMed

    Inanli, Selçuk; Oztürk, Ozmen; Korkmaz, Mukadder; Tutkun, Alper; Batman, Cağlar

    2002-02-01

    The aims of the study were to determine: 1) how mucociliary activity in acute bacterial rhinosinusitis is affected; 2) how this activity is changed by therapy; 3) the effects of topical agents on mucociliary clearance, and 4) the most appropriate topical agent(s) to be used in the therapy of sinusitis. Five groups of patients with acute bacterial rhinosinusitis were studied prospectively. All patients had 500 mg oral amoxicillin and 125 mg oral clavulanic acid preparations given three times daily for 3 weeks. According to the topical agent applications, these groups included: group I (n = 12), no topical treatment was given; group II (n = 14), two puffs for each nostril once daily of 50 microg/100 mL fluticasone propionate was given; group III (n = 9), one puff for each nostril three times daily of 0.05% oxymetazoline was given; group IV (n =12), 3% sodium chloride (NaCl) (buffered to pH 6.5-7 at room temperature) was given; and group V (n =13), 10-mL solutions of 0.9% NaCl (buffered to pH 6.5--7 at room temperature) were given for nasal irrigations three times daily. All patients had medication for 3 weeks and were controlled each week. The saccharin method was used to measure nasal mucociliary clearance. To investigate the early effects of the topical agents for groups II to V, an additional test was repeated 20 minutes after the basal mucociliary clearance recordings. The test was repeated in the first, second, and third weeks of the treatment. The mucociliary clearance was significantly slower in the acute bacterial rhinosinusitis group than in the control group. There was no significant difference between the basal mucociliary clearance and the 20th minute mucociliary clearance of the fluticasone propionate and 0.9% NaCl solution groups. The mean values of the basal and the 20 minute's mucociliary clearance of the oxymetazoline group were 24.72 +/- 6.16 and 15.5 +/- 7.45 minutes, respectively, which were statistically significant. The mean values of the basal and the 20th minute mucociliary clearance of the 3% NaCl solution groups were 19.45 +/- 9.35 and 15.45 +/- 8.20 minutes, respectively, which were also statistically significant. In the first group (without topical treatment), the basal mucociliary clearance became significantly shorter after the second week of treatment. In the first and second weeks of the treatment of the oxymetazoline group, the mucociliary clearance did not change significantly, but after the third week the mucociliary clearance was significantly shorter. In the 3% NaCl solution group, significant improvement began from the first week and continued through the third week. Comparing the basal and the third weeks' mucociliary clearance values among the groups, the oxymetazoline and 3% NaCl solution groups revealed more significant improvement than the other groups, but this improvement was not different from the improvement of group I. There was still a statistically significant difference in the mucociliary clearance of the post-treatment sinusitis groups from the control group. The oxymetazoline and 3% NaCl solution groups seemed to be more effective in mucociliary clearance, but there was no significant difference in improvement among the groups. The improvement of acute bacterial rhinosinusitis takes more than 3 weeks, according to the mucociliary clearance values of the groups.

  20. Phosphate Removal by Peritoneal Dialysis: The Effect of Transporter Status and Peritoneal Dialysis Prescription.

    PubMed

    Courivaud, Cecile; Davenport, Andrew

    2016-01-01

    ♦ Interventional trials failed to demonstrate that increasing urea clearance improved peritoneal dialysis (PD) patient survival. Hyperphosphatemia is a well-recognized predictor of cardiovascular and all-cause mortality in PD patients. Simplification of PD small solute clearance targets focuses away from larger solutes, including phosphate. In the US and UK, increasing use of automated peritoneal dialysis (APD) cyclers with shorter dwell times could also potentially reduce peritoneal phosphate removal compared to continuous ambulatory peritoneal dialysis (CAPD). ♦ Total phosphate and peritoneal phosphate clearances were measured in a prospective observational cohort of 380 adult PD patients attending a tertiary university hospital between 1996 and 2013 for routine assessment of PD adequacy. ♦ Eighty-seven patients (22.9%) were hyperphosphatemic. Taking the mean 4-hour dialysate to plasma (D/P) ratio for phosphate, 193 (50.8%) were fast and fast-average transporters and 187 (49.2%) were slow and slow-average transporters (compared to 276 [72.6%] and 104 [27.4%], respectively, for peritoneal creatinine transporter status). Faster peritoneal phosphate transporter status was associated with over-hydration (odds ratio [OR] = 2.45 [1.43 - 4.20], p = 0.001). Whereas the 4-hour D/P creatinine and peritoneal weekly creatinine clearance did not differ between those who were hyperphosphatemic or not, the hyperphosphatemic patients had lower 4-hour D/P phosphate and lower peritoneal weekly phosphate clearance (p = 0.019, and p = 0.06 respectively). We found greater peritoneal phosphate clearance for patients choosing CAPD compared to APD, irrespective of the peritoneal phosphate transporter status. ♦ Peritoneal creatinine transporter status and creatinine clearance cannot be used as surrogate markers of peritoneal phosphate transport and clearance. Hyperphosphatemia was more common in PD patients with slower peritoneal transporter status and lower peritoneal phosphate clearance. Greater peritoneal phosphate clearance was achieved with CAPD prescriptions. Slower peritoneal transporters should be advised to choose CAPD to improve serum phosphate control. Copyright © 2016 International Society for Peritoneal Dialysis.

  1. Phosphate Removal by Peritoneal Dialysis: The Effect of Transporter Status and Peritoneal Dialysis Prescription

    PubMed Central

    Courivaud, Cecile; Davenport, Andrew

    2016-01-01

    ♦ Background: Interventional trials failed to demonstrate that increasing urea clearance improved peritoneal dialysis (PD) patient survival. Hyperphosphatemia is a well-recognized predictor of cardiovascular and all-cause mortality in PD patients. Simplification of PD small solute clearance targets focuses away from larger solutes, including phosphate. In the US and UK, increasing use of automated peritoneal dialysis (APD) cyclers with shorter dwell times could also potentially reduce peritoneal phosphate removal compared to continuous ambulatory peritoneal dialysis (CAPD). ♦ Methods: Total phosphate and peritoneal phosphate clearances were measured in a prospective observational cohort of 380 adult PD patients attending a tertiary university hospital between 1996 and 2013 for routine assessment of PD adequacy. ♦ Results: Eighty-seven patients (22.9%) were hyperphosphatemic. Taking the mean 4-hour dialysate to plasma (D/P) ratio for phosphate, 193 (50.8%) were fast and fast-average transporters and 187 (49.2%) were slow and slow-average transporters (compared to 276 [72.6%] and 104 [27.4%], respectively, for peritoneal creatinine transporter status). Faster peritoneal phosphate transporter status was associated with over-hydration (odds ratio [OR] = 2.45 [1.43 – 4.20], p = 0.001). Whereas the 4-hour D/P creatinine and peritoneal weekly creatinine clearance did not differ between those who were hyperphosphatemic or not, the hyperphosphatemic patients had lower 4-hour D/P phosphate and lower peritoneal weekly phosphate clearance (p = 0.019, and p = 0.06 respectively). We found greater peritoneal phosphate clearance for patients choosing CAPD compared to APD, irrespective of the peritoneal phosphate transporter status. ♦ Conclusion: Peritoneal creatinine transporter status and creatinine clearance cannot be used as surrogate markers of peritoneal phosphate transport and clearance. Hyperphosphatemia was more common in PD patients with slower peritoneal transporter status and lower peritoneal phosphate clearance. Greater peritoneal phosphate clearance was achieved with CAPD prescriptions. Slower peritoneal transporters should be advised to choose CAPD to improve serum phosphate control. PMID:26224788

  2. Assessment of kidney function in children by enzymatic determination of 2- or 24-h creatinine clearance: comparison with inulin clearance.

    PubMed

    Uemura, Osamu; Nagai, Takuhito; Yamakawa, Satoshi; Kaneko, Tetsuji; Hibi, Yoshiko; Yamasaki, Yasuhito; Yamamoto, Masaki; Nakano, Masaru; Iwata, Naoyuki; Hibino, Satoshi

    2016-06-01

    Although renal inulin clearance (Cin) is the gold standard for evaluation of kidney function, it cannot be measured easily. Therefore, creatinine clearance (Ccr) is often used clinically to evaluate kidney function. Enzymatically measured Ccr was recently found to be much higher than Cin because of the tubular secretion of creatinine (Cr). This study compared three measures of renal clearance, inulin, 2-h Ccr, and 24-h Ccr, in children. Kidney function was evaluated in 76 children (51 males and 25 females) aged 1 month to 18 years with chronic kidney disease (CKD) by three renal clearance methods at almost the same time. Correlations between each pair of three renal clearance measurements were determined. Approximate glomerular filtration rate (GFR) was equal to 62 % of 2-h Ccr or 76 % of 24-h Ccr. Cr secretion by renal tubules was approximately 50 % of the GFR. In this study, we indicate that the measurements of 2-h Ccr or 24-h Ccr do not show true GFR but we could infer approximate GFR from the values. The use of 2- or 24-h Ccr might contribute to the treatment of pediatric CKD patients.

  3. The tear turnover and tear clearance tests - a review.

    PubMed

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  4. Deformation Analysis of the Main Components in a Single Screw Compressor

    NASA Astrophysics Data System (ADS)

    Liu, Feilong; Liao, Xueli; Feng, Quanke; Van Den Broek, Martijn; De Paepe, Michel

    2015-08-01

    The single screw compressor is used in many fields such as air compression, chemical industry and refrigeration. During operation, different gas pressures and temperatures applied on the components can cause different degrees of deformation, which leads to a difference between the thermally induced clearance and the designed clearance. However, limited research about clearance design is reported. In this paper, a temperature measurement instrument and a convective heat transfer model were described and used to establish the temperature of a single screw air compressor's casing, screw rotor and star wheel. 3-D models of these three main components were built. The gas force deformation, thermal- structure deformation and thermal-force coupling deformation were carried out by using a finite element simulation method. Results show that the clearance between the bottom of the groove and the top of star wheel is reduced by 0.066 mm, the clearance between the side of groove and the star wheel is reduced by 0.015 mm, and the clearance between the cylinder and the rotor is reduced by 0.01 mm. It is suggested that these deformations should be taken into account during the design of these clearances.

  5. Agalsidase Benefits Renal Histology in Young Patients with Fabry Disease

    PubMed Central

    Bostad, Leif; Larsen, Kristin Kampevold; Hirth, Asle; Vikse, Bjørn Egil; Houge, Gunnar; Svarstad, Einar

    2012-01-01

    The effect of early-onset enzyme replacement therapy on renal morphologic features in Fabry disease is largely unknown. Here, we evaluated the effect of 5 years of treatment with agalsidase alfa or agalsidase beta in 12 consecutive patients age 7–33 years (median age, 16.5 years). We performed renal biopsies at baseline and after 5 years of enzyme replacement therapy; 7 patients had additional biopsies after 1 and 3 years. After a median of 65 months, biopsy findings from all patients showed total clearance of glomerular endothelial and mesangial cell inclusions, and findings from 2 patients showed complete clearance of inclusions from epithelial cells of the distal tubule. The 4 patients who received the highest dose of agalsidase exhibited substantial clearance of podocyte inclusions, and the youngest patient had nearly complete clearance of these inclusions. Linear regression analysis showed a highly significant correlation between podocyte globotriaocylceramide clearance and cumulative agalsidase dose (r=0.804; P=0.002). Microalbuminuria normalized in five patients. In summary, long-term enzyme replacement therapy in young patients can result in complete globotriaocylceramide clearance of mesangial and glomerular endothelial cells across all dosage regimens, and clearance of podocyte inclusions is dose-dependent. PMID:23274955

  6. UXO clearance operation in Laos

    NASA Astrophysics Data System (ADS)

    Sato, Motoyuki; Kadoya, Yoshihiko

    2018-04-01

    Laos is one of the most seriously contaminated countries by UXO. Most of the UXO are cluster bombs, used in 1960- 70's. There is historical political background about the UXO problems in Laos. Currently, The clearance of UXO is significantly important for future economic development for Laos. It affects not only local inhabitants, but it will affects national economy. For example, UXO clearance in mountainous area can promote construction of roads, and Laos has a good possibility to be the center of transportation in Indo-Chia region. We have started a research project for evaluation of impact of UXO clearance in Laos, "The economic impact and the technological development for the elimination of unexploded ordnance (UXO) elimination in Laos". Lao National Unexploded Ordnance Programme (UXO Lao) is working in the nine most impacted provinces nationwide and it clears land for agriculture and community purposes. We recently visited Laos and observed the UXO clearance procedure conducted by UXOLAO. The technical survey for UXO clearance site to determine for operation, UXO detection by using metal detectors are organized by UXO Lao. In this paper, we will report the technical aspects of the UXO clearance in Laos.

  7. Genome-wide study of methotrexate clearance replicates SLCO1B1

    PubMed Central

    Ramsey, Laura B.; Panetta, John C.; Smith, Colton; Yang, Wenjian; Fan, Yiping; Winick, Naomi J.; Martin, Paul L.; Cheng, Cheng; Devidas, Meenakshi; Pui, Ching-Hon; Evans, William E.; Hunger, Stephen P.; Loh, Mignon

    2013-01-01

    Methotrexate clearance can influence the cure of and toxicity in children with acute lymphoblastic leukemia (ALL). We estimated methotrexate plasma clearance for 1279 patients with ALL treated with methotrexate (24-hour infusion of a 1 g/m2 dose or 4-hour infusion of a 2 g/m2 dose) on the Children's Oncology Group P9904 and P9905 protocols. Methotrexate clearance was lower in older children (P = 7 × 10−7), girls (P = 2.7 × 10−4), and those who received a delayed-intensification phase (P = .0022). A genome-wide analysis showed that methotrexate clearance was associated with polymorphisms in the organic anion transporter gene SLCO1B1 (P = 2.1 × 10−11). This replicates findings using different schedules of high-dose methotrexate in St Jude ALL treatment protocols; a combined meta-analysis yields a P value of 5.7 × 10−19 for the association of methotrexate clearance with SLCO1B1 SNP rs4149056. Validation of this variant with 5 different treatment regimens of methotrexate solidifies the robustness of this pharmacogenomic determinant of methotrexate clearance. This study is registered at http://www.clinicaltrials.gov as NCT00005585 and NCT00005596. PMID:23233662

  8. Radial Clearance Found To Play a Key Role in the Performance of Compliant Foil Air Bearings

    NASA Technical Reports Server (NTRS)

    Radil, Kevin C.

    2003-01-01

    Compliant foil air bearings are at the forefront of the Oil-Free turbomachinery revolution, which supports gas turbine engines with hydrodynamic bearings that use air instead of oil as the working fluid. These types of bearings have been around for almost 50 years and have found a home in several commercial applications, such as in air cycle machines, turbocompressors, and microturbines, but are now being aggressively pursued for use in small and midrange aircraft gas turbine engines. Benefits include higher operating speeds and temperatures, lower maintenance costs, and greater reliability. The Oil-Free Turbomachinery team at the NASA Glenn Research Center is working to foster the transition of Oil-Free technology into gas turbine engines by performing in-house experiments on foil air bearings in order to gain a greater insight into their complex operating principles. A research program recently undertaken at Glenn focused on the concept of radial clearance and its influence on bearing performance. The tests were conducted on foil bearings with different radial clearances. As defined for a foil bearing, radial clearance is a measure of the small amount of shaft radial motion that is present from play that exists in the elastic support structure, such as between the top and bump foils and the bump foils and bearing shell (see the drawing). With an insufficient amount of radial clearance, the bearing imparts a high preload on the shaft, which when excessive, can reduce the loadcarrying capability of the bearing. On the other hand, systems using foil bearings with excessive radial clearance may experience rotordynamic instabilities because of low bearing preload. Therefore, without a more thorough understanding of radial clearance, it is difficult to accurately predict the performance of a given bearing design. The test program demonstrated that there is a direct correlation between radial clearance and the performance of foil air bearings. As shown in the graph, an optimum radial clearance exists that will maximize the amount of load that the bearing is capable of supporting. With respect to this optimum, two different performance regimes were observed that are a function of the amount of radial clearance. Tests showed that bearings with radial clearances below the optimum in regime I were susceptible to sudden seizure, a failure mode indicative of thermal runaway caused by high preload. The high preload is in response to an insufficient amount of radial clearance available to accommodate the thermal growth of the bearing and shaft. However, radial clearances greater than the optimum in regime II resulted in low bearing preloads that did not cause any heat-related problems, and the failure mode was due to fluid-film breakdown. In fact, bearings operating with radial clearances twice as much as the optimum suffered a decrease in the maximum load capacity of only about 20 percent. Therefore, special attention has to be given to the range of operating conditions expected in the bearing/shaft system since changes in temperature, centrifugal, and hydrodynamic effects can all affect radial clearance. This enhanced understanding of foil air bearing behavior will greatly aid our efforts to transition Oil-Free technology to future aircraft engines.

  9. 15 CFR 752.15 - Export clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Export clearance. 752.15 Section 752... OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE EXPORT ADMINISTRATION REGULATIONS SPECIAL COMPREHENSIVE LICENSE § 752.15 Export clearance. (a) Shipper's Export Declaration (SED) or Automated Export...

  10. 75 FR 57829 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-22

    ... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2010... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Commuter...

  11. 76 FR 28500 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2011... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Agricultural...

  12. 76 FR 45645 - 10-Day Notice of Proposed Information Collection: Technology Security/Clearance Plans, Screening...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ...: Technology Security/Clearance Plans, Screening Records, and Non-Disclosure Agreements ACTION: Notice of... Information Collection: Technology Security/ Clearance Plans, Screening Records, and Non-Disclosure Agreements...: None. Respondents: Business and Nonprofit Organizations, Foreign Governments. Estimated Number of...

  13. 32 CFR 154.77 - Reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... took the action, using the enclosed format: (1) Number of Top Secret, Secret, and Confidential clearances issued; (2) Number of Top Secret, Secret, and Confidential clearances denied; (3) Number of Top...) Total number of personnel holding a clearance for Top Secret, Secret, Confidential and Sensitive...

  14. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... transported in-bond, or when they have unentered foreign merchandise aboard. For the purposes of the vessel clearance requirements, merchandise transported in-bond does not include bonded ship's stores or supplies. While American vessels transporting unentered foreign merchandise must fully comply with usual clearance...

  15. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  16. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  17. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  18. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  19. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  20. Test Rig for Active Turbine Blade Tip Clearance Control Concepts: An Update

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn; Steinetz, Bruce; Oswald, Jay; DeCastro, Jonathan; Melcher, Kevin

    2006-01-01

    The objective is to develop and demonstrate a fast-acting active clearance control system to improve turbine engine performance, reduce emissions, and increase service life. System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA's Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.

  1. Adequacy of peritoneal dialysis: beyond small solute clearance.

    PubMed

    Goldberg, Ryan; Yalavarthy, Rajesh; Teitelbaum, Isaac

    2009-01-01

    Peritoneal dialysis adequacy is monitored primarily by indices of small solute clearance, Kt/V(urea) and creatinine clearance (C(cr)). Once a threshold of adequacy has been obtained, however, increasing small solute clearance does not result in improved long-term outcomes of PD patients. There are several other factors that may affect optimal dialysis outcomes. These include, but are not limited to: ultrafiltration, inflammation, malnutrition, and mineral metabolism. In this article, we will briefly review data regarding the relationships between these factors and survival on PD.

  2. Plasma interferon-gamma-inducible protein-10 (IP-10) levels during acute hepatitis C virus infection

    PubMed Central

    Grebely, Jason; Feld, Jordan J.; Applegate, Tanya; Matthews, Gail V.; Hellard, Margaret; Sherker, Alana; Petoumenos, Kathy; Zang, Geng; Shaw, Ineke; Yeung, Barbara; George, Jacob; Teutsch, Suzy; Kaldor, John M.; Cherepanov, Vera; Bruneau, Julie; Shoukry, Naglaa H.; Lloyd, Andrew R.; Dore, Gregory J.

    2013-01-01

    Systemic levels of interferon-gamma-inducible protein-10 (IP-10) are predictive of treatment-induced clearance in chronic HCV. In the present study, factors associated with plasma IP-10 levels at the time of acute HCV detection and the association between IP-10 levels and spontaneous clearance were assessed in three cohorts of acute HCV infection. Among 300 individuals, 245 (181 male, 47 HIV+) were HCV RNA+ at acute HCV detection. In adjusted analysis, factors independently associated with IP-10 levels ≥150 pg/mL (median level) included HCV RNA levels >6 log IU/mL, HIV co-infection and non-Aboriginal ethnicity. Among 245 HCV RNA+ at acute HCV detection, 214 were untreated (n=137) or had persistent infection (infection duration ≥26 weeks) at treatment initiation (n=77). Spontaneous clearance occurred in 14% (29 of 214). Individuals without spontaneous clearance had significantly higher mean plasma IP-10 levels at the time of acute HCV detection than those with clearance (248±32 vs. 142±22 pg/mL, P=0.008). The proportion of individuals with spontaneous clearance was 0% (0 of 22, P=0.048) and 16% (27 of 165) and in those in those with and without plasma IP-10 levels ≥380 pg/mL. In adjusted analyses, favourable IL28B genotype was associated with spontaneous clearance, while higher HCV RNA level was independently associated with lower odds of spontaneous clearance. Conclusion High IP-10 levels at acute HCV detection were associated with failure to spontaneously clear HCV. Patients with acute HCV and high baseline IP-10 levels, particularly >380 pg/mL, should be considered for early therapeutic intervention, and those with low levels should defer therapy for potential spontaneous clearance. PMID:23325615

  3. Duration and clearance of anal human papillomavirus (HPV) infection among women: the Hawaii HPV cohort study.

    PubMed

    Shvetsov, Yurii B; Hernandez, Brenda Y; McDuffie, Katharine; Wilkens, Lynne R; Zhu, Xuemei; Ning, Lily; Killeen, Jeffrey; Kamemoto, Lori; Goodman, Marc T

    2009-03-01

    The association of anal cancer with human papillomavirus (HPV) infection is well established; however, little is known about the epidemiology of anal HPV in healthy women. We investigated patterns of duration and clearance of anal HPV infection in a cohort of healthy women in Hawaii. Viral and nonviral determinants of anal HPV clearance were examined in a longitudinal cohort study of 431 sexually active women. At baseline and at 4-month intervals, interviews were conducted and cervical and anal cell specimens were obtained for detection of HPV DNA. Of the 431 women, 50% experienced a total of 414 incident anal HPV infections, reported at 1 clinic visits from baseline through a follow-up period of average duration of 1.2 years. Of these infections, 58% cleared during follow-up. The clearance rate for a high-risk anal infection was 9.2 per 100 woman-months (95% confidence interval [CI], 6.9-11.9 per 100 woman-months), with a median duration of 150 days (95% CI, 132-243 days). The slowest clearing high-risk HPV types were HPV-59 (median clearance time, 350 days) and HPV-58 (median clearance time, 252 days). The median clearance times for HPV-16 and HPV-18, the predominant types associated with anal cancer, were 132 days and 212 days, respectively. Nonviral factors that delayed clearance of anal HPV included douching, long-term tobacco smoking, and anal sex. The majority of anal HPV infections resolve in a relatively short time. Although anal HPV is commonly acquired in healthy women, its rapid clearance suggests limited efficacy of HPV testing as an anal cancer screening tool.

  4. Pharmacokinetics of paracetamol and its metabolites in women at delivery and post‐partum

    PubMed Central

    Kulo, Aida; Peeters, Mariska Y.; Allegaert, Karel; Smits, Anne; de Hoon, Jan; Verbesselt, Rene; Lewi, Liesbeth; van de Velde, Marc; Knibbe, Catherijne A. J.

    2013-01-01

    Aim A recent report on intravenous (i.v.) paracetamol pharmacokinetics (PK) showed a higher total clearance in women at delivery compared with non‐pregnant women. To describe the paracetamol metabolic and elimination routes involved in this increase in clearance, we performed a population PK analysis in women at delivery and post‐partum in which the different pathways were considered. Methods Population PK parameters using non‐linear mixed effect modelling were estimated in a two‐period PK study in women to whom i.v. paracetamol (2 g loading dose followed by 1 g every 6 h up to 24 h) was administered immediately following Caesarean delivery and in a subgroup of the same women to whom single 2 g i.v.loading dose was administered 10–15 weeks post‐partum. Results Population PK analysis was performed based on 255 plasma and 71 urine samples collected in 39 women at delivery and in eight of these 39 women 12 weeks post‐partum. Total clearance was higher in women at delivery compared with 12th post‐partum week (21.1 vs. 11.7 l h−1) due to higher clearances to paracetamol glucuronide (11.6 vs. 4.76 l h−1), to oxidative metabolites (4.95 vs. 2.77 l h−1) and of unchanged paracetamol (1.15 vs. 0.75 l h−1). In contrast, there was no difference in clearance to paracetamol sulphate. Conclusion The increased total paracetamol clearance at delivery is caused by a disproportional increase in glucuronidation clearance and a proportional increase in clearance of unchanged paracetamol and in oxidation clearance, of which the latter may potentially limit further dose increase in this patient group. PMID:22845052

  5. Evaluating the Use of Antibody Variable Region (Fv) Charge as a Risk Assessment Tool for Predicting Typical Cynomolgus Monkey Pharmacokinetics*

    PubMed Central

    Bumbaca Yadav, Daniela; Sharma, Vikas K.; Boswell, Charles Andrew; Hotzel, Isidro; Tesar, Devin; Shang, Yonglei; Ying, Yong; Fischer, Saloumeh K.; Grogan, Jane L.; Chiang, Eugene Y.; Urban, Konnie; Ulufatu, Sheila; Khawli, Leslie A.; Prabhu, Saileta; Joseph, Sean; Kelley, Robert F.

    2015-01-01

    The pharmacokinetic (PK) behavior of monoclonal antibodies in cynomolgus monkeys (cynos) is generally translatable to that in humans. Unfortunately, about 39% of the antibodies evaluated for PKs in cynos have fast nonspecific (or non-target-mediated) clearance (in-house data). An empirical model relating variable region (Fv) charge and hydrophobicity to cyno nonspecific clearance was developed to gauge the risk an antibody would have for fast nonspecific clearance in the monkey. The purpose of this study was to evaluate the predictability of this empirical model on cyno nonspecific clearance with antibodies specifically engineered to have either high or low Fv charge. These amino acid changes were made in the Fv region of two test antibodies, humAb4D5-8 and anti-lymphotoxin α. The humAb4D5-8 has a typical nonspecific clearance in cynos, and by making it more positively charged, the antibody acquires fast nonspecific clearance, and making it less positively charged did not impact its clearance. Anti-lymphotoxin α has fast nonspecific clearance in cynos, and making it more positively charged caused it to clear even faster, whereas making it less positively charged caused it to clear slower and within the typical range. These trends in clearance were also observed in two other preclinical species, mice and rats. The effect of modifying Fv charge on subcutaneous bioavailability was also examined, and in general bioavailability was inversely related to the direction of the Fv charge change. Thus, modifying Fv charge appears to impact antibody PKs, and the changes tended to correlate with those predicted by the empirical model. PMID:26491012

  6. Dexmedetomidine metabolic clearance is not affected by fat mass in obese patients.

    PubMed

    Rolle, A; Paredes, S; Cortínez, L I; Anderson, B J; Quezada, N; Solari, S; Allende, F; Torres, J; Cabrera, D; Contreras, V; Carmona, J; Ramírez, C; Oliveros, A M; Ibacache, M

    2018-05-01

    Obesity has been associated with reduced dexmedetomidine clearance, suggesting impaired hepatic function or reduced hepatic blood flow. The aim of this study was to clarify the effect of obesity in dexmedetomidine metabolic clearance. Forty patients, ASA I-III, 18-60 yr old, weighing 47-126 kg, scheduled for abdominal laparoscopic surgery, were enrolled. Anaesthetic agents (propofol, remifentanil, and dexmedetomidine) were dosed based on lean body weight measured by dual X-ray absorptiometry. Serial venous samples were drawn during and after dexmedetomidine infusion. A pharmacokinetic analysis was undertaken using non-linear mixed-effect models. In the modelling approach, the total body weight, lean body weight, and adjusted body weight were first tested as size descriptors for volumes and clearances. Hepatic blood flow, liver histopathology, liver enzymes, and gene expression of metabolic enzymes (UGT2B10 and UGT1A4) were tested as covariates of dexmedetomidine metabolic clearance. A decrease in NONMEM objective function value (ΔOFV) of 3.84 points, for an added parameter, was considered significant at the 0.05 level. A total of 637 dexmedetomidine serum samples were obtained. A two-compartmental model scaled to measured lean weight adequately described the dexmedetomidine pharmacokinetics. Liver blood flow was a covariate for dexmedetomidine clearance (ΔOFV=-5.878). Other factors, including fat mass, histopathological damage, and differential expression of enzymes, did not affect the dexmedetomidine clearance in the population studied (ΔOFV<3.84). We did not find a negative influence of obesity in dexmedetomidine clearance when doses were adjusted to lean body weight. Liver blood flow showed a significant effect on dexmedetomidine clearance. NCT02557867. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  7. Higher serum levels of uric acid are associated with a reduced insulin clearance in non-diabetic individuals.

    PubMed

    Fiorentino, Teresa Vanessa; Sesti, Franz; Succurro, Elena; Pedace, Elisabetta; Andreozzi, Francesco; Sciacqua, Angela; Hribal, Marta Letizia; Perticone, Francesco; Sesti, Giorgio

    2018-05-17

    Decreased insulin clearance has been reported to be associated with insulin resistance-related disorders and incident type 2 diabetes. The aim of this study was to evaluate whether higher levels of uric acid (UA), a known risk factor of type 2 diabetes, are associated with a reduced insulin clearance. 440 non-diabetic individuals were stratified in tertiles according to serum UA levels. Insulin clearance and skeletal muscle insulin sensitivity were assessed by euglycemic hyperinsulinemic clamp. Hepatic insulin resistance was estimated by the liver IR index. Subjects with higher levels of UA displayed an unfavorable metabolic phenotype with a worse lipid profile, increased levels of 2-h post-load glucose levels, fasting, and 2-h post-load insulin levels, hsCRP, liver IR index, and lower levels of eGFR and skeletal muscle insulin sensitivity, in comparison to individuals with lower UA levels. Moreover, subjects with higher UA concentrations exhibited decreased levels of insulin clearance even after adjustment for age, gender, BMI, eGFR, and skeletal muscle insulin sensitivity. In a multivariate regression analysis model including several confounding factors, UA concentration was an independent predictor of insulin clearance (β = - 0.145; P = 0.03). However, when liver IR index was included in the model, the independent association between UA levels and insulin clearance was not retained. Accordingly, in a mediation analysis, liver IR index was a mediator of the negative effects of UA levels on insulin clearance (t = - 2.55, P = 0.01). Higher serum levels of UA may affect insulin clearance by impairing hepatic insulin sensitivity.

  8. Compressor airfoil tip clearance optimization system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary.more » During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.« less

  9. 78 FR 74175 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-10

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  10. 76 FR 77835 - Agency Forms Undergoing Paperwork Reduction Act Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-14

    ... Project Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery--new... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... . SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  11. 78 FR 76849 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-19

    ... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Request (ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... proposed information collection activity provides a means to garner qualitative customer and stakeholder...

  12. 19 CFR 122.77 - Clearance certificate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Clearance certificate. 122.77 Section 122.77 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic...

  13. 76 FR 45573 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ... Technology Research Center survey. Abstract: The information collection activity will garner qualitative.... This type of generic clearance for qualitative information will not be used for quantitative... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  14. Reduced erythrocyte susceptibility and increased host clearance of young parasites slows Plasmodium growth in a murine model of severe malaria

    NASA Astrophysics Data System (ADS)

    Khoury, David S.; Cromer, Deborah; Best, Shannon E.; James, Kylie R.; Sebina, Ismail; Haque, Ashraful; Davenport, Miles P.

    2015-05-01

    The best correlate of malaria severity in human Plasmodium falciparum (Pf) infection is the total parasite load. Pf-infected humans could control parasite loads by two mechanisms, either decreasing parasite multiplication, or increasing parasite clearance. However, few studies have directly measured these two mechanisms in vivo. Here, we have directly quantified host clearance of parasites during Plasmodium infection in mice. We transferred labelled red blood cells (RBCs) from Plasmodium infected donors into uninfected and infected recipients, and tracked the fate of donor parasites by frequent blood sampling. We then applied age-based mathematical models to characterise parasite clearance in the recipient mice. Our analyses revealed an increased clearance of parasites in infected animals, particularly parasites of a younger developmental stage. However, the major decrease in parasite multiplication in infected mice was not mediated by increased clearance alone, but was accompanied by a significant reduction in the susceptibility of RBCs to parasitisation.

  15. Clearance Properties of Nano-sized Particles and Molecules as Imaging Agents: Considerations and Caveats

    PubMed Central

    Longmire, Michelle; Choyke, Peter L.; Kobayashi, Hisataka

    2009-01-01

    Summary Nanoparticles possess enormous potential as diagnostic imaging agents and hold promise for the development of multimodality agents with both imaging and therapeutic capabilities. Yet, some of the most promising nanoparticles demonstrate prolonged tissue retention and contain heavy metals. This presents serious concerns for toxicity. The creation of nanoparticles with optimal clearance characteristics will minimize toxicity risks by reducing the duration of exposure to these agents. Given that many nanoparticles possess easily modifiable surface and interior chemistry, if nanoparticle characteristics associated with optimal clearance from the body were well established, it would be feasible to design and create agents with more favorable clearance properties. This paper presents a thorough discussion of the physiologic aspects of nanoparticle clearance, focusing on renal mechanisms, as well as provides an overview of current research investigating clearance of specific types of nanoparticles and nano-sized macromolecules, including dendrimers, quantum dots, liposomes and carbon, gold, and silica-based nanoparticles. PMID:18817471

  16. Influence of blade tip rounding on tip leakage vortex cavitation of axial flow pump

    NASA Astrophysics Data System (ADS)

    Wu, S. Q.; Shi, W. D.; Zhang, D. S.; Yao, J.; Cheng, C.

    2013-12-01

    Tip leakage flow in axial flow pumps is mainly caused by the tip clearance, which is the main cause of tip leakage vortex cavitation and blade tip cavitation erosion. In order to improve tip clearance flow and reduce TLV cavitation, four schemes were adopted to the round blade tip. These are: no tip rounding, one time tip clearance tip rounding, two times tip clearance tip rounding, four times tip clearance tip rounding. Using SST k-ω turbulence model and Zwart cavitation model in CFX software, this simulation obtained four kinds of inner flow field results. The numerical results indicated that with the increase of r*, NPSHc gradually increased and the cavitation performance reduced. However, corner vortex was eliminated so that cavitation in gap was restrained. But TLV vorticity increased and cavitation's range here had a little expansion. Combined with the research of this paper and the different analyses of four schemes, we recommend adopting the two times of the tip clearance rounding.

  17. The role of lectins and glycans in platelet clearance

    PubMed Central

    Hoffmeister, Karin M.

    2015-01-01

    Summary In recent years, it has become increasingly apparent that the life span of transfused platelets in circulation is regulated, at least in part, by glycan-lectin mediated mechanisms. There is clear evidence that refrigerated platelets are cleared by glycan-lectin mediated clearance mechanisms. Acute platelet cooling clusters glycoprotein (GP) Ibα receptors bearing uncovered N-acetylglucosamine (GlcNAc), and αMβ2 integrins on hepatic macrophages recognise clustered GlcNAc to rapidly clear these platelets from circulation. With prolonged refrigeration GPIbα clustering bearing uncovered galactose increases, which mediates the removal of long-term refrigerated platelets via hepatic Ashwell-Morell receptors (AMR), originally named as asialoglycoprotein receptors. In contrast, little is known about the molecular mechanisms of transfused room temperature platelet clearance. This review examines the role of glycan-lectin mediated clearance of exogenous, i.e. transfused chilled platelet clearance and briefly addresses the current knowledge of stored platelet function, degradation and its relation to platelet clearance. PMID:21781240

  18. Oral sugar clearance and root caries prevalence in rheumatic patients with dry mouth symptoms.

    PubMed

    Risheim, H; Arneberg, P; Birkhed, D

    1992-01-01

    The relationship between root caries, oral sugar clearance, salivary flow rate, and salivary counts of mutans streptococci, lactobacilli and candida has been studied in a group of 22 rheumatic patients (age range 40-72 years). The study group comprised all subjects volunteering for a clinical trial on relief of dry mouth symptoms. The median salivary flow was 0.09 ml/min at rest and 0.9 ml/min during chewing stimulation. The median sugar clearance time was about 5 min in the sublingual area and 16 min in the lower buccal vestibule. For subjects with 0-2 root caries lesions the clearance time at both sites was shorter than for subjects with 3 or more lesions (p < 0.05). A long oral clearance time was significantly correlated with age, root caries (DS and DFS), low resting salivary flow, and high salivary counts of mutans streptococci. It is concluded that root caries in rheumatic patients with low salivary flow is significantly related to oral sugar clearance time.

  19. Schwann cells use TAM receptor-mediated phagocytosis in addition to autophagy to clear myelin in a mouse model of nerve injury.

    PubMed

    Brosius Lutz, Amanda; Chung, Won-Suk; Sloan, Steven A; Carson, Glenn A; Zhou, Lu; Lovelett, Emilie; Posada, Sean; Zuchero, J Bradley; Barres, Ben A

    2017-09-19

    Ineffective myelin debris clearance is a major factor contributing to the poor regenerative ability of the central nervous system. In stark contrast, rapid clearance of myelin debris from the injured peripheral nervous system (PNS) is one of the keys to this system's remarkable regenerative capacity, but the molecular mechanisms driving PNS myelin clearance are incompletely understood. We set out to discover new pathways of PNS myelin clearance to identify novel strategies for activating myelin clearance in the injured central nervous system, where myelin debris is not cleared efficiently. Here we show that Schwann cells, the myelinating glia of the PNS, collaborate with hematogenous macrophages to clear myelin debris using TAM (Tyro3, Axl, Mer) receptor-mediated phagocytosis as well as autophagy. In a mouse model of PNS nerve crush injury, Schwann cells up-regulate TAM phagocytic receptors Axl and Mertk following PNS injury, and Schwann cells lacking both of these phagocytic receptors exhibit significantly impaired myelin phagocytosis both in vitro and in vivo. Autophagy-deficient Schwann cells also display reductions in myelin clearance after mouse nerve crush injury, as has been recently shown following nerve transection. These findings add a mechanism, Axl/Mertk-mediated myelin clearance, to the repertoire of cellular machinery used to clear myelin in the injured PNS. Given recent evidence that astrocytes express Axl and Mertk and have previously unrecognized phagocytic potential, this pathway may be a promising avenue for activating myelin clearance after CNS injury.

  20. 76 FR 35069 - Agency Information Collection Activities; Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-15

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...; Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  1. 76 FR 13338 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-11

    ... Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Administrative Conference of the United... Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service.... SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  2. 76 FR 17861 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-31

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  3. 76 FR 20714 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-13

    ... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork...: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. Abstract...

  4. 76 FR 24920 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  5. 76 FR 40981 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-12

    ...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Qualitative Feedback on Agency Service Delivery '' to OMB for approval under the Paperwork Reduction Act (PRA... 20590. SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on...

  6. 76 FR 41280 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-13

    ... proposed sample size, the expected response rate, methods for assessing potential non-response bias, the... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  7. 77 FR 52708 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-30

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  8. 32 CFR 644.521 - Limitations on clearance cost.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Limitations on clearance cost. 644.521 Section 644.521 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed...

  9. 32 CFR 644.522 - Clearance of military scrap.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of military scrap. 644.522 Section 644.522 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed...

  10. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  11. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  12. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  13. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  14. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  15. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  16. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  17. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  18. 10 CFR 10.21 - Suspension of access authorization and/or employment clearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... ELIGIBILITY FOR ACCESS TO RESTRICTED DATA OR NATIONAL SECURITY INFORMATION OR AN EMPLOYMENT CLEARANCE... access authorization and/or an employment clearance, the Director, Division of Facilities and Security... Corporate Management and Chief Information Officer or other Deputy Executive Director, his or her...

  19. 10 CFR 10.21 - Suspension of access authorization and/or employment clearance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... ELIGIBILITY FOR ACCESS TO RESTRICTED DATA OR NATIONAL SECURITY INFORMATION OR AN EMPLOYMENT CLEARANCE... access authorization and/or an employment clearance, the Director, Division of Facilities and Security... Corporate Management and Chief Information Officer or other Deputy Executive Director, his or her...

  20. 77 FR 32144 - Agency Information Collection Activities: Comment Request; Generic Survey Clearance for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... Survey Clearance for the Directorate of Education and Human Resources (EHR) AGENCY: National Science.... The scope of the EHR Generic Clearance primarily covers descriptive information gathered from... evaluations of individual programs. The collections generally include three categories of descriptive data: (1...

  1. 49 CFR 230.110 - Pilots.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pilots. 230.110 Section 230.110 Transportation... and Equalizing System § 230.110 Pilots. (a) General provisions. Pilots shall be securely attached... clearance. The minimum clearance of pilot above the rail shall be 3 inches and the maximum clearance shall...

  2. 75 FR 38775 - Proposed Information Collection; Comment Request; Generic Clearance for Customer Satisfaction...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-06

    ...; Generic Clearance for Customer Satisfaction Research AGENCY: U.S. Census Bureau. ACTION: Notice. SUMMARY... Bureau is requesting an extension of the generic clearance to conduct customer satisfaction research... on feedback from its various customer satisfaction research efforts. Each research design is reviewed...

  3. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...

  4. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...

  5. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...

  6. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...

  7. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  8. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  9. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  10. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  11. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  12. 76 FR 22937 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-25

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for approval under the... INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  13. 76 FR 25693 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-05

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  14. 76 FR 37825 - Agency Information Collection Activities; Generic Clearance for the Collection of Qualitative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-28

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Activities; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  15. 76 FR 13020 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-09

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  16. 76 FR 14948 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork Reduction Act (PRA... the CPSC Docket No. CPSC [ ] and the title ``Generic Clearance for the Collection of Qualitative...

  17. 78 FR 26087 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-03

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for approval under the.... SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  18. 76 FR 15027 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... clustering), the precision requirements or power calculations that justify the proposed sample size, the...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  19. 76 FR 19826 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  20. 75 FR 80542 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-22

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  1. 76 FR 13019 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-09

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  2. 76 FR 20967 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-14

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  3. 76 FR 70460 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-14

    ... of Qualitative Feedback on Agency Service Delivery ACTION: 30-Day notice of submission of information... Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service... INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  4. 77 FR 2659 - Airworthiness Directives; Cessna Aircraft Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-19

    ...), and of the bearing cup for corrosion, turned cup, or clearance that exceeds limits, and repair as... cup for corrosion, turned cup, or clearance that exceeds limits, and repair if necessary; measuring... on the metal), and of the bearing cup for corrosion, turned cup, or clearance that exceeds limits...

  5. 32 CFR 644.517 - Clearance of Army lands.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of Army lands. 644.517 Section 644.517 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed Excess Land...

  6. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  7. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  8. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  9. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  10. 78 FR 22020 - Agency Information Collection Activities: Requests for Comments; Clearance of New Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-12

    ... Control Number: 2120-XXXX. Title: Safety Awareness, Feedback, and Evaluation (SAFE) Program. Form Numbers: No FAA forms are associated with this collection. Type of Review: Clearance of a new information... Activities: Requests for Comments; Clearance of New Approval of Information Collection: Safety Awareness...

  11. Benefits of Improved HP Turbine Active Clearance Control

    NASA Technical Reports Server (NTRS)

    Ruiz, Rafael; Albers, Bob; Sak, Wojciech; Seitzer, Ken; Steinetz, Bruce M.

    2007-01-01

    As part of the NASA Propulsion 21 program, GE Aircraft Engines was contracted to develop an improved high pressure turbine(HPT) active clearance control (ACC) system. The system is envisioned to minimize blade tip clearances to improve HPT efficiency throughout the engine operation range simultaneously reducing fuel consumption and emissions.

  12. 49 CFR 392.12 - Highway-rail crossings; safe clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Highway-rail crossings; safe clearance. 392.12... DRIVING OF COMMERCIAL MOTOR VEHICLES Driving of Commercial Motor Vehicles § 392.12 Highway-rail crossings; safe clearance. No driver of a commercial motor vehicle shall drive onto a highway-rail grade crossing...

  13. 49 CFR 392.12 - Highway-rail crossings; safe clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Highway-rail crossings; safe clearance. 392.12... DRIVING OF COMMERCIAL MOTOR VEHICLES Driving of Commercial Motor Vehicles § 392.12 Highway-rail crossings; safe clearance. No driver of a commercial motor vehicle shall drive onto a highway-rail grade crossing...

  14. 5 CFR 1320.11 - Clearance of collections of information in proposed rules.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Clearance of collections of information in proposed rules. 1320.11 Section 1320.11 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET OMB DIRECTIVES CONTROLLING PAPERWORK BURDENS ON THE PUBLIC § 1320.11 Clearance of collections of...

  15. 5 CFR 1320.12 - Clearance of collections of information in current rules.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Clearance of collections of information in current rules. 1320.12 Section 1320.12 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET OMB DIRECTIVES CONTROLLING PAPERWORK BURDENS ON THE PUBLIC § 1320.12 Clearance of collections of...

  16. 77 FR 56866 - Agency Information Collection Activities: Proposed Collection; Comment Request, Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-14

    ... Collection Activities: Proposed Collection; Comment Request, Generic Clearance for Cognitive, Pilot and Field... information collection clearance that will allow BJS to conduct a variety of cognitive, pilot, and field test... new or modified data collection, BJS will engage in cognitive, pilot and field test activities to...

  17. 77 FR 69658 - Agency Information Collection Activities; Proposed Collection; Comment Request: Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-20

    ... Activities; Proposed Collection; Comment Request: Generic Clearance for Cognitive, Pilot and Field Studies...) Title of the Form/Collection: BJS Generic Clearance for Cognitive, Pilot, and Field Test Studies. (3... respondents will be involved in exploratory, field test, pilot, cognitive, and focus group work conducted...

  18. 77 FR 56867 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-14

    ... Collection Activities: Proposed Collection; Comment Request; Generic Clearance for Cognitive, Pilot and Field... information collection clearance that will allow BJS to conduct a variety of cognitive, pilot, and field test... new or modified data collection, BJS will engage in cognitive, pilot and field test activities to...

  19. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress Payments Based on Costs 832.502-2 Contract finance office clearance. Contracting...

  20. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress Payments Based on Costs 32.502-2 Contract finance office clearance. The contracting...

  1. 76 FR 49838 - Proposed Collection; Comment Request for Generic Clearance for the Collection of Qualitative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-11

    ... Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Internal... of Qualitative Feedback on Agency Service Delivery. DATES: Written comments should be received on or... . SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  2. 78 FR 69643 - Proposed Information Collection; Comment Request; Generic Clearance for Customer Satisfaction...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-20

    ... Clearance for Customer Satisfaction Research AGENCY: U.S. Census Bureau, Commerce. ACTION: Notice. SUMMARY... requesting an extension of the generic clearance to conduct customer satisfaction research which may be in... feedback from its various customer satisfaction research efforts. Each research design is reviewed for...

  3. 76 FR 77244 - Renewal of Information Collection; OMB Control Number 1040-0001, DOI Programmatic Clearance for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-12

    ... Number 1040-0001, DOI Programmatic Clearance for Customer Satisfaction Surveys AGENCY: Department of [email protected] . Reference ``DOI Programmatic Clearance for Customer Satisfaction Surveys'' in your email... public accountability by promoting a new focus on results, service quality, and customer satisfaction...

  4. 14 CFR 135.361 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... distance from the point at which the obstruction clearance plane associated with the approach end of the... subpart, obstruction clearance plane means a plane sloping upward from the runway at a slope of 1:20 to... coincides with the centerline of the runway, beginning at the point where the obstruction clearance plane...

  5. 14 CFR 121.171 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... point at which the obstruction clearance plane associated with the approach end of the runway intersects... clearance plane means a plane sloping upward from the runway at a slope of 1:20 to the horizontal, and... centerline of the runway, beginning at the point where the obstruction clearance plane intersects the...

  6. Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance

    NASA Technical Reports Server (NTRS)

    Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.

    2002-01-01

    This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.

  7. Simple geometric algorithms to aid in clearance management for robotic mechanisms

    NASA Technical Reports Server (NTRS)

    Copeland, E. L.; Ray, L. D.; Peticolas, J. D.

    1981-01-01

    Global geometric shapes such as lines, planes, circles, spheres, cylinders, and the associated computational algorithms which provide relatively inexpensive estimates of minimum spatial clearance for safe operations were selected. The Space Shuttle, remote manipulator system, and the Power Extension Package are used as an example. Robotic mechanisms operate in quarters limited by external structures and the problem of clearance is often of considerable interest. Safe clearance management is simple and suited to real time calculation, whereas contact prediction requires more precision, sophistication, and computational overhead.

  8. Does sleep disturbance affect the amyloid clearance mechanisms in Alzheimer's disease?

    PubMed

    Yulug, Burak; Hanoglu, Lutfu; Kilic, Ertugrul

    2017-10-01

    Sleep is an important factor that plays a key role in Alzheimer's disease pathogenesis. However, it is still unclear whether poor-quality sleep may overlap with sleep disturbances in the underlying dysfunctional mechanisms of amyloid beta (Aβ) clearance metabolism. Here, we aimed to evaluate the current evidence on the role of sleep deprivation in Aβ clearance metabolism. To that end, we discuss possible mechanisms underlying the bidirectional interaction between the sleep deprivation and Aβ clearance pathways. © 2017 The Authors. Psychiatry and Clinical Neurosciences © 2017 Japanese Society of Psychiatry and Neurology.

  9. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan.

    PubMed

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-11-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) "Regulations on Clearance Level for Radioactive Waste Management". The testing results should conform to the deviation and traceability requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. JT9D-70/59 Improved High Pressure Turbine Active Clearance Control System. [for specific fuel consumption improvement

    NASA Technical Reports Server (NTRS)

    Gaffin, W. O.

    1979-01-01

    The JT9D-70/59 high pressure turbine active clearance control system was modified to provide reduction of blade tip clearance when the system is activated during cruise operation. The modification increased the flow capacity and air impingement effectiveness of the cooling air manifold to augment turbine case shrinkage capability, and increased responsiveness of the airseal clearance to case shrinkage. The simulated altitude engine testing indicated a significant improvement in specific fuel consumption with the modified system. A 1000 cycle engine endurance test showed no unusual wear or performance deterioration effects on the engine or the clearance control system. Rig tests indicated that the air impingement and seal support configurations used in the engine tests are near optimum.

  11. Output Error Analysis of Planar 2-DOF Five-bar Mechanism

    NASA Astrophysics Data System (ADS)

    Niu, Kejia; Wang, Jun; Ting, Kwun-Lon; Tao, Fen; Cheng, Qunchao; Wang, Quan; Zhang, Kaiyang

    2018-03-01

    Aiming at the mechanism error caused by clearance of planar 2-DOF Five-bar motion pair, the method of equivalent joint clearance of kinematic pair to virtual link is applied. The structural error model of revolute joint clearance is established based on the N-bar rotation laws and the concept of joint rotation space, The influence of the clearance of the moving pair is studied on the output error of the mechanis. and the calculation method and basis of the maximum error are given. The error rotation space of the mechanism under the influence of joint clearance is obtained. The results show that this method can accurately calculate the joint space error rotation space, which provides a new way to analyze the planar parallel mechanism error caused by joint space.

  12. Application of an in vitro OAT assay in drug design and optimization of renal clearance.

    PubMed

    Soars, Matthew G; Barton, Patrick; Elkin, Lisa L; Mosure, Kathleen W; Sproston, Joanne L; Riley, Robert J

    2014-07-01

    1. Optimization of renal clearance is a complex balance between passive and active processes mediated by renal transporters. This work aimed to characterize the interaction of a series of compounds with rat and human organic anion transporters (OATs) and develop quantitative structure-activity relationships (QSARs) to optimize renal clearance. 2. In vitro inhibition assays were established for human OAT1 and rat Oat3 and rat in vivo renal clearance was obtained. Statistically significant quantitative relationships were explored between the compounds' physical properties, their affinity for OAT1 and oat3 and the inter-relationship with unbound renal clearance (URC) in rat. 3. Many of the compounds were actively secreted and in vitro analysis demonstrated that these were ligands for rat and human OAT transporters (IC50 values ranging from <1 to >100 µM). Application of resultant QSAR models reduced renal clearance in the rat from 24 to <0.1 ml/min/kg. Data analysis indicated that the properties associated with increasing affinity at OATs are the same as those associated with reducing URC but orthogonal in nature. 4. This study has demonstrated that OAT inhibition data and QSAR models can be successfully used to optimize rat renal clearance in vivo and provide confidence of translation to humans.

  13. ADAPTIVE CLEARANCE CONTROL SYSTEMS FOR TURBINE ENGINES

    NASA Technical Reports Server (NTRS)

    Blackwell, Keith M.

    2004-01-01

    The Controls and Dynamics Technology Branch at NASA Glenn Research Center primarily deals in developing controls, dynamic models, and health management technologies for air and space propulsion systems. During the summer of 2004 I was granted the privilege of working alongside professionals who were developing an active clearance control system for commercial jet engines. Clearance, the gap between the turbine blade tip and the encompassing shroud, increases as a result of wear mechanisms and rubbing of the turbine blades on shroud. Increases in clearance cause larger specific fuel consumption (SFC) and loss of efficient air flow. This occurs because, as clearances increase, the engine must run hotter and bum more fuel to achieve the same thrust. In order to maintain efficiency, reduce fuel bum, and reduce exhaust gas temperature (EGT), the clearance must be accurately controlled to gap sizes no greater than a few hundredths of an inch. To address this problem, NASA Glenn researchers have developed a basic control system with actuators and sensors on each section of the shroud. Instead of having a large uniform metal casing, there would be sections of the shroud with individual sensors attached internally that would move slightly to reform and maintain clearance. The proposed method would ultimately save the airline industry millions of dollars.

  14. Use of specific radioimmunoassays to determine the renal clearance rates of estrone and 17. beta. -estradiol during the menstrual cycle. [Tritium tracer techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, K.; Collins, D.C.; Preedy, J.R.K.

    Specific RIAs requiring ether extraction only were established for estrone and 17..beta..-estradiol both in plasma and in urine from the nonpregnant female. These assays were used to measure the renal clearance rates of estrone and of 17..beta..-estradiol in eight ambulatory women in the follicular and in the luteal phases of the menstrual cycle. The mean (+-SE) for the renal clearance rate of estrone was 0.71 +- 0.058 ml/min in the follicular phase and 1.26 +- 0.35 ml/min in the luteal phase. The mean (+-SE) renal clearance rate of 17..beta..-estradiol was 0.44 +- 0.055 ml/min in the follicular phase and 0.29more » +- 0.043 ml/min in the luteal phase. There was no significant difference in the renal clearance rates of either estrone or of 17..beta..-estradiol between the follicular and luteal phases of the cycle. The renal clearances of estrone and 17..beta..-estradiol were highly correlated (r = 0.84; P < 0.01). The renal clearance rate of estrone was significantly greater than that of 17..beta..-estradiol in both phases of the cycle (P < 0.01).« less

  15. The tribological behaviour of different clearance MOM hip joints with lubricants of physiological viscosities.

    PubMed

    Hu, X Q; Wood, R J K; Taylor, A; Tuke, M A

    2011-11-01

    Clearance is one of the most influential parameters on the tribological performance of metal-on-metal (MOM) hip joints and its selection is a subject of considerable debate. The objective of this paper is to study the lubrication behaviour of different clearances for MOM hip joints within the range of human physiological and pathological fluid viscosities. The frictional torques developed by MOM hip joints with a 50 mm diameter were measured for both virgin surfaces and during a wear simulator test. Joints were manufactured with three different diametral clearances: 20, 100, and 200 microm. The fluid used for the friction measurements which contained different ratios of 25 percent newborn calf serum and carboxymethyl cellulose (CMC) with the obtained viscosities values ranging from 0.001 to 0.71 Pa s. The obtained results indicate that the frictional torque for the 20 microm clearance joint remains high over the whole range of the viscosity values. The frictional torque of the 100 microm clearance joint was low for the very low viscosity (0.001 Pa s) lubricant, but increased with increasing viscosity value. The frictional torque of the 200 microm clearance joint was high at very low viscosity levels, however, it reduced with increasing viscosity. It is concluded that a smaller clearance level can enhance the formation of an elastohydrodynamic lubrication (EHL) film, but this is at the cost of preventing fluid recovery between the bearing surfaces during the unloaded phase of walking. Larger clearance bearings allow a better recovery of lubricant during the unloaded phase, which is necessary for higher viscosity lubricants. The selection of the clearance value should therefore consider both the formation of the EHL film and the fluid recovery as a function of the physiological viscosity in order to get an optimal tribological performance for MOM hip joints. The application of either 25 per cent bovine serum or water in existing in vitro tribological study should also be revised to consider the relevance of clinic synovial fluid viscosities and to avoid possible misleading results.

  16. Transitional probability-based model for HPV clearance in HIV-1-positive adolescent females.

    PubMed

    Kravchenko, Julia; Akushevich, Igor; Sudenga, Staci L; Wilson, Craig M; Levitan, Emily B; Shrestha, Sadeep

    2012-01-01

    HIV-1-positive patients clear the human papillomavirus (HPV) infection less frequently than HIV-1-negative. Datasets for estimating HPV clearance probability often have irregular measurements of HPV status and risk factors. A new transitional probability-based model for estimation of probability of HPV clearance was developed to fully incorporate information on HIV-1-related clinical data, such as CD4 counts, HIV-1 viral load (VL), highly active antiretroviral therapy (HAART), and risk factors (measured quarterly), and HPV infection status (measured at 6-month intervals). Data from 266 HIV-1-positive and 134 at-risk HIV-1-negative adolescent females from the Reaching for Excellence in Adolescent Care and Health (REACH) cohort were used in this study. First, the associations were evaluated using the Cox proportional hazard model, and the variables that demonstrated significant effects on HPV clearance were included in transitional probability models. The new model established the efficacy of CD4 cell counts as a main clearance predictor for all type-specific HPV phylogenetic groups. The 3-month probability of HPV clearance in HIV-1-infected patients significantly increased with increasing CD4 counts for HPV16/16-like (p<0.001), HPV18/18-like (p<0.001), HPV56/56-like (p = 0.05), and low-risk HPV (p<0.001) phylogenetic groups, with the lowest probability found for HPV16/16-like infections (21.60±1.81% at CD4 level 200 cells/mm(3), p<0.05; and 28.03±1.47% at CD4 level 500 cells/mm(3)). HIV-1 VL was a significant predictor for clearance of low-risk HPV infections (p<0.05). HAART (with protease inhibitor) was significant predictor of probability of HPV16 clearance (p<0.05). HPV16/16-like and HPV18/18-like groups showed heterogeneity (p<0.05) in terms of how CD4 counts, HIV VL, and HAART affected probability of clearance of each HPV infection. This new model predicts the 3-month probability of HPV infection clearance based on CD4 cell counts and other HIV-1-related clinical measurements.

  17. Alcohol consumption decreases lactate clearance in acutely injured patients☆

    PubMed Central

    Dezman, Zachary D.W.; Comer, Angela C.; Narayan, Mayur; Scalea, Thomas M.; Hirshon, Jon Mark; Smith, Gordon S.

    2017-01-01

    Introduction Alcohol, a common risk factor for injury, has direct toxic effects on the liver. The use of lactate clearance has been well described as an indicator of the adequacy of resuscitation in injured patients. We investigated whether acutely injured patients with positive blood alcohol content (+BAC) had less lactate clearance than sober patients. Methods We conducted a retrospective cohort study of acutely injured patients treated at an urban Level 1 trauma centre between January 2010 and December 2012. Blood alcohol and venous lactate levels were measured on all patients at the time of arrival. Study subjects were patients transported directly from the scene of injury, who had an elevated lactate concentration on arrival (≥3.0 mmol/L) and at least one subsequent lactate measurement within 24 h after admission. Lactate clearance ([Lactate1 − Lactate2]/Lactate1) was calculated for all patients. Chi-squared tests were used to compare values from sober and intoxicated subjects. Lactate clearance was plotted against alcohol levels and stratified by age and Injury Severity Score (ISS). Results Serial lactate concentration measurements were obtained in 3910 patients; 1674 of them had +BAC. Patients with +BAC were younger (mean age: 36.6 [SD 14.7] vs 41.0 [SD 19.9] years [p = 0.0001]), were more often male (83.4% vs 75.9% [p = 0.0001]), had more minor injuries (ISS < 9) (33.8% vs 27.1% [p = 0.0001]), had a lower in-hospital mortality rate (1.4% vs 3.9% [p = 0.0001]), but also had lower average lactate clearance (37.8% vs 47.6% [p = 0.0001]). The lactate clearance of the sober patients (47.6 [SD 33.5]) was twice that of those with +BAC >400 (23.5 [SD 6.5]). Lactate clearance decreased with increasing BAC irrespective of age and ISS. Conclusions In a large group of acutely injured patients, a dose-dependent decrease in lactate clearance was seen in those with elevated BAC. This relationship will cause a falsely elevated lactate reading or prolong lactate clearance and should be taken into account when evaluating patients with +BAC. PMID:27025567

  18. High-dose methotrexate therapy of childhood acute lymphoblastic leukemia: lack of relation between serum methotrexate concentration and creatinine clearance.

    PubMed

    Joannon, Pilar; Oviedo, Iris; Campbell, Myriam; Tordecilla, Juan

    2004-07-01

    The objectives of this study were: (1) to analyze the relation of serum methotrexate (MTX) concentration with creatinine clearance, (2) to compare the leucovorin rescue dose administered to the patients based on creatinine clearance, with the one calculated according to serum MTX levels, and (3) to determine MTX-related toxicity. Thirty children with high-risk non-B acute lymphoblastic leukemia (ALL) treated according to the national protocol (PINDA 92) based on ALL BFM 90, were randomized to receive consolidation with four doses of either 1 or 2 g/m(2) MTX as a 24-hr infusion, at 2-week intervals (group M1 and M2, respectively). Serum MTX concentrations were measured at 24, 42, and 48 hr after beginning the infusion and were analyzed retrospectively. The creatinine clearance was calculated after 12-hr intravenous hydration prior to each MTX dose. Leucovorin dosage was adjusted according to creatinine clearance. Serum MTX concentrations at 24, 42, and 48 hr after starting the infusion were not related to creatinine clearance in both treatment groups. Leucovorin rescue administered according to creatinine clearance was excessive in 43% in group M1 and in 51% in group M2, as compared to the dose calculated according to serum MTX levels. No serious clinical complications were observed. These results suggest that creatinine clearance is not a good parameter to calculate leucovorin rescue. MTX-related toxicity in this group of patients receiving a dose of 1 or 2 g/m(2) and rescued with leucovorin without monitoring serum MTX levels was acceptable. Copyright 2004 Wiley-Liss, Inc.

  19. Interferon lambda 4 (IFNL4) gene polymorphism is associated with spontaneous clearance of HCV in HIV-1 positive patients.

    PubMed

    Alves, Camila Fernanda da Silveira; Grott, Camila Schultz; Lunge, Vagner Ricardo; Béria, Jorge Umberto; Tietzmann, Daniela Cardoso; Stein, Airton Tetelbom; Simon, Daniel

    2016-01-01

    Approximately one-third of the individuals infected with human immunodeficiency virus type 1 (HIV-1) are co-infected with hepatitis C virus (HCV). Co-infected patients have an increased risk for developing end-stage liver diseases. Variants upstream of the IFNL3 gene have been associated with spontaneous and treatment-induced clearance of HCV infection. Recently, a novel polymorphism was discovered, denoted IFNL4 ΔG > TT (rs368234815), which seems to be a better predictor of spontaneous clearance than the IFNL4 rs12979860 polymorphism. We aimed to determine the prevalence of the IFNL4 ΔG > TT variants and to evaluate the association with spontaneous clearance of HCV infection in Brazilian HIV-1 patients. The IFNL4 ΔG > TT genotypes were analyzed by polymerase chain reaction followed by restriction digestion in 138 HIV-1 positive patients who had an anti-HCV positive result. Spontaneous clearance of HCV was observed in 34 individuals (24.6%). IFNL4 genotype distribution was significantly different between individuals who had spontaneous clearance and chronic HCV patients (p=0.002). The probability of spontaneous clearance of HCV infection for patients with the IFNL4 TT/TT genotype was 3.6 times higher than for patients carrying the IFNL4 ΔG allele (OR=3.63, 95% CI:1.51-8.89, p=0.001). The IFNL4 ΔG > TT polymorphism seems to be better than IFNL4 rs12979860 to predict spontaneous clearance of the HCV in Brazilian HIV-1 positive patients.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, H.B.; Blaufox, M.D.

    Rats with one kidney clamped (2K1C), both kidneys clamped (2K2C), unilaterally nephrectomized with remaining kidney clamped (1K1C), and normals, were studied using /sup 99m/Tc mercaptoacetyltriglycine ((/sup 99m/Tc)MAG-3) and /sup 131/I orthoiodohippurate ((/sup 131/I)OIH). Clearances of (/sup 99m/Tc)MAG-3 and (/sup 131/I)OIH were performed after constricted rats became hypertensive. Clearances were repeated after i.v. Captopril. Clearances of (/sup 99m/Tc)MAG-3 and (/sup 131/I)OIH in normals didn't change significantly after Captopril. Clearances of (/sup 99m/Tc)MAG-3 and (/sup 131/I)OIH decreased insignificantly after Captopril in the 2K2C model. in the 2K1C group, normal kidney clearance increased ((/sup 99m/Tc)MAG-3 p less than 0.01 and (/sup 131/I)OIH pmore » less than 0.025) and clamped kidney clearance decreased after inhibition ((/sup 99m/Tc)MAG-3, p less than 0.01, (/sup 131/I)OIH p less than 0.02). Clearances increased in the 1K1C group after Captopril ((/sup 99m/Tc)MAG-3 p less than 0.0025 and (/sup 131/I)OIH, p less than 0.001). The ratio of (/sup 99m/Tc)MAG-3 to (/sup 131/I)OIH before Captopril was 0.81 and 0.84 after Captopril. Changes in renal function after Captopril depend on the model of renovascular hypertension and possibly the dose administered. Technetium-99m MAG-3 clearance parallels (/sup 131/I)orthoiodohippurate in renovascular hypertension.« less

  1. Semi-mechanistic autoinduction model of midazolam in critically ill patients: population pharmacokinetic analysis.

    PubMed

    Aoyama, T; Hirata, K; Yamamoto, Y; Yokota, H; Hayashi, H; Aoyama, Y; Matsumoto, Y

    2016-08-01

    Midazolam (MDZ) is commonly used for sedating critically ill patients. The daily dose required for adequate sedation increases in increments over 100 h after administration. The objectives of this study were to characterize the MDZ pharmacokinetics in critically ill patients and to describe the phenomenon of increasing daily dose by means of population pharmacokinetic analysis. Data were obtained from 30 patients treated in an intensive care unit. The patients received MDZ intravenously as a combination of bolus and continuous infusion. Serum MDZ concentration was assayed by high-performance liquid chromatography. Population pharmacokinetic analysis was performed using the NONMEM software package. The alteration of clearance unexplained by demographic factors and clinical laboratory data was described as an autoinduction of MDZ clearance using a semi-mechanistic pharmacokinetic-enzyme turnover model. The final population pharmacokinetic model was a one-compartment model estimated by incorporating a semi-mechanistic pharmacokinetic-enzyme turnover model for clearance, taking autoinduction into account. A significant covariate for MDZ clearance was total bilirubin. An increase in total bilirubin indicated a reduction in MDZ clearance. From simulation using the population pharmacokinetic parameters obtained in this study, MDZ clearance increased 2·3 times compared with pre-induced clearance 100 h after the start of 12·5 mg/h continuous infusion. Autoinduction and total bilirubin were significant predictors of the clearance of MDZ in this population. Step-by-step dosage adjustment using this population pharmacokinetic model may be useful for establishing a MDZ dosage regimen in critically ill patients. © 2016 John Wiley & Sons Ltd.

  2. Interferon lambda 4 (IFNL4) gene polymorphism is associated with spontaneous clearance of HCV in HIV-1 positive patients

    PubMed Central

    Alves, Camila Fernanda da Silveira; Grott, Camila Schultz; Lunge, Vagner Ricardo; Béria, Jorge Umberto; Tietzmann, Daniela Cardoso; Stein, Airton Tetelbom; Simon, Daniel

    2016-01-01

    Abstract Approximately one-third of the individuals infected with human immunodeficiency virus type 1 (HIV-1) are co-infected with hepatitis C virus (HCV). Co-infected patients have an increased risk for developing end-stage liver diseases. Variants upstream of the IFNL3 gene have been associated with spontaneous and treatment-induced clearance of HCV infection. Recently, a novel polymorphism was discovered, denoted IFNL4 ΔG > TT (rs368234815), which seems to be a better predictor of spontaneous clearance than the IFNL4 rs12979860 polymorphism. We aimed to determine the prevalence of the IFNL4 ΔG > TT variants and to evaluate the association with spontaneous clearance of HCV infection in Brazilian HIV-1 patients. The IFNL4 ΔG > TT genotypes were analyzed by polymerase chain reaction followed by restriction digestion in 138 HIV-1 positive patients who had an anti-HCV positive result. Spontaneous clearance of HCV was observed in 34 individuals (24.6%). IFNL4 genotype distribution was significantly different between individuals who had spontaneous clearance and chronic HCV patients (p=0.002). The probability of spontaneous clearance of HCV infection for patients with the IFNL4 TT/TT genotype was 3.6 times higher than for patients carrying the IFNL4 ΔG allele (OR=3.63, 95% CI:1.51-8.89, p=0.001). The IFNL4 ΔG > TT polymorphism seems to be better than IFNL4 rs12979860 to predict spontaneous clearance of the HCV in Brazilian HIV-1 positive patients. PMID:27560987

  3. Population Pharmacokinetics of Ceftizoxime Administered by Continuous Infusion in Clinically Ill Adult Patients

    PubMed Central

    Facca, Bryan; Frame, Bill; Triesenberg, Steve

    1998-01-01

    Ceftizoxime is a widely used beta-lactam antimicrobial agent, but pharmacokinetic data for use with clinically ill patients are lacking. We studied the population pharmacokinetics of ceftizoxime in 72 clinically ill patients at a community-based, university-affiliated hospital. A population pharmacokinetic model for ceftizoxime was created by using a prospective observational design. Ceftizoxime was administered by continuous infusion to treat patients with proven or suspected bacterial infections. While the patients were receiving infusions of ceftizoxime, serum samples were collected for pharmacokinetic analysis with the nonlinear mixed-effect modeling program NONMEM. In addition to clearance and volume of distribution, various comorbidities were examined for their influence on the kinetics. All 72 subjects completed the study, and 114 serum samples were collected. Several demographic and comorbidity variables, namely, age, weight, serum creatinine levels, congestive heart failure, and long-term ventilator dependency, had a significant impact on the estimate for ceftizoxime clearance. A mixture model, or two populations for estimation of ceftizoxime clearance, was discovered. One population presented with an additive clearance component of 1.6 liters per h. In addition, a maximizer function for serum creatinine levels was found. In summary, two models for ceftizoxime clearance, mixture and nonmixture, were found and are presented. Clearance for ceftizoxime can be estimated with commonly available clinical information and the models presented. From the clearance estimates, the dose of ceftizoxime to maintain the desired concentration in serum can be determined. Work is needed to validate the model for drug clearance and to evaluate its predictive performance. PMID:9661021

  4. 20 CFR 653.501 - Requirements for accepting and processing clearance orders.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF LABOR SERVICES OF THE EMPLOYMENT SERVICE SYSTEM Agricultural Clearance Order Activity § 653.501... function of the job service as a no-fee labor exchange, that is, as a forum for bringing together employers... referred through the clearance system shall be notified to contact a local job service office, preferably...

  5. 20 CFR 653.501 - Requirements for accepting and processing clearance orders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., DEPARTMENT OF LABOR SERVICES OF THE EMPLOYMENT SERVICE SYSTEM Agricultural Clearance Order Activity § 653.501... function of the job service as a no-fee labor exchange, that is, as a forum for bringing together employers... referred through the clearance system shall be notified to contact a local job service office, preferably...

  6. 75 FR 75189 - 30-Day Notice of Proposed Information Collection: Form DS-3057, Medical Clearance Update, OMB...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-02

    ... on whether a federal employee and family members will have sufficient medical resources at a...-3057, Medical Clearance Update, OMB 1405-0131 ACTION: Notice of request for public comments. SUMMARY... Reduction Act of 1995. Title of Information Collection: Medical Clearance Update. OMB Control Number: 1405...

  7. 75 FR 62444 - 60-Day Notice of Proposed Information Collection: Form DS-3057, Medical Clearance Update, OMB...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-08

    ... employee and family members will have sufficient medical resources at a diplomatic mission abroad to...-3057, Medical Clearance Update, OMB 1405-0131 ACTION: Notice of request for public comments. SUMMARY... the Paperwork Reduction Act of 1995. Title of Information Collection: Medical Clearance Update. OMB...

  8. 32 CFR 644.516 - Clearance of Air Force lands.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of Air Force lands. 644.516 Section 644... Excess Land and Improvements § 644.516 Clearance of Air Force lands. The Chief of Engineers has no responsibility for inspecting or clearing excess Air Force land of explosives or chemical/biological contaminants...

  9. Towards improved models for predicting bioconcentration of well-metabolized compounds by rainbow trout using measured rates of in vitro intrinsic clearance

    EPA Science Inventory

    Consensus models were developed to predict the bioconcentration of well-metabolized chemicals by rainbow trout. The models employ intrinsic clearance data from in vitro studies with liver S9 fractions or isolated hepatocytes to estimate a liver clearance rate which is extrapolat...

  10. Hepatic clearance of 6 polyaromatic aromatic hydrocarbons by isolated trout livers: Prediction from in vitro clearance by liver S9 fractions

    EPA Science Inventory

    An isolated perfused trout liver preparation was used to evaluate in vitro-to-in vivo metabolism extrapolation procedures for fish. Hepatic clearance (CLH) studies were conducted with six polyaromatic hydrocarbons (PAH) using an experimental design wherein each liver acted as it...

  11. 77 FR 47492 - Agency Information Collection Activities: Requests for Comments; Clearance of a New Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-08

    ... collection. This is a new generic clearance for the purpose of gathering customer satisfaction data directly from customers for a wide variety of services. DATES: Written comments should be submitted by October 9... Activities: Requests for Comments; Clearance of a New Approval of Information Collection: FAA Customer...

  12. 78 FR 5855 - Agency Information Collection Activities: Requests for Comments; Clearance of a New Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-28

    ... generic clearance for the purpose of gathering customer satisfaction data directly from customers for a... Activities: Requests for Comments; Clearance of a New Approval of Information Collection: FAA Customer... INFORMATION: OMB Control Number: 2120-XXXX Title: FAA Customer Service Surveys Form Numbers: There are no FAA...

  13. 49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Open-wire transmission line; clearance to other..., AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts or...

  14. 49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Open-wire transmission line; clearance to other..., AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts or...

  15. 14 CFR 103.23 - Flight visibility and cloud clearance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...

  16. 14 CFR 103.23 - Flight visibility and cloud clearance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...

  17. 14 CFR 103.23 - Flight visibility and cloud clearance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...

  18. 14 CFR 103.23 - Flight visibility and cloud clearance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...

  19. 14 CFR 103.23 - Flight visibility and cloud clearance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...

  20. 10 CFR 10.21 - Suspension of access authorization and/or employment clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Suspension of access authorization and/or employment clearance. 10.21 Section 10.21 Energy NUCLEAR REGULATORY COMMISSION CRITERIA AND PROCEDURES FOR DETERMINING... Procedures § 10.21 Suspension of access authorization and/or employment clearance. In those cases where...

  1. 10 CFR 10.21 - Suspension of access authorization and/or employment clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Suspension of access authorization and/or employment clearance. 10.21 Section 10.21 Energy NUCLEAR REGULATORY COMMISSION CRITERIA AND PROCEDURES FOR DETERMINING... Procedures § 10.21 Suspension of access authorization and/or employment clearance. In those cases where...

  2. 10 CFR 10.21 - Suspension of access authorization and/or employment clearance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Suspension of access authorization and/or employment clearance. 10.21 Section 10.21 Energy NUCLEAR REGULATORY COMMISSION CRITERIA AND PROCEDURES FOR DETERMINING... Procedures § 10.21 Suspension of access authorization and/or employment clearance. In those cases where...

  3. 76 FR 17615 - Highway-Rail Grade Crossing; Safe Clearance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ...-2006-25660] RIN 2137-AE69 & 2126-AB04 Highway-Rail Grade Crossing; Safe Clearance AGENCY: Pipeline and... PHMSA and FMCSA extend the comment period for the Highway-Rail Grade Crossing; Safe Clearance Notice of... Alliance (CVSA) requested that PHMSA and FMCSA extend the comment period for the Highway-Rail Grade...

  4. An Evaluation of the Venous Equilibrium Model for Hepatic Clearance using Isolated Perfused Rainbow Trout Livers

    EPA Science Inventory

    The venous equilibrium model is widely used to describe hepatic clearance (CLH) of chemicals metabolized by the liver. If chemical delivery to the tissue does not limit CLH, this model predicts that CLH will approximately equal the product of intrinsic metabolic clearance and a t...

  5. 77 FR 56865 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-14

    ... Collection Activities: Proposed Collection; Comment Request; Generic Clearance for Cognitive, Pilot and Field... information collection clearance that will allow BJS to conduct a variety of cognitive, pilot, and field test... each new or modified data collection, BJS will engage in cognitive, pilot and field test activities to...

  6. 14 CFR 99.17 - Deviation from flight plans and ATC clearances and instructions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Deviation from flight plans and ATC clearances and instructions. 99.17 Section 99.17 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... TRAFFIC General § 99.17 Deviation from flight plans and ATC clearances and instructions. (a) No pilot may...

  7. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress Payments Based on Costs 1432.502-2 Contract finance office clearance. The CO shall...

  8. Intelligent Engine Systems: HPT Clearance Control

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Advanced Thermally Actuated Clearance Control System underwent several studies. Improved flow path isolation quantified what can be gained by making the HPT case nearly adiabatic. The best method of heat transfer was established, and finally two different borrowed air cooling circuits were evaluated to be used for the HPT Active Clearance Control System.

  9. 14 CFR 29.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Ground clearance: tail rotor guard. 29.411 Section 29.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 29.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  10. 14 CFR 27.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Ground clearance: tail rotor guard. 27.411 Section 27.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 27.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  11. 14 CFR 27.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Ground clearance: tail rotor guard. 27.411 Section 27.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 27.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  12. 14 CFR 29.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Ground clearance: tail rotor guard. 29.411 Section 29.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 29.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  13. 31 CFR 205.20 - What is a clearance pattern?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., unless additional data is required to accurately represent the flow of Federal funds. (e) If a State uses... FEDERAL-STATE FUNDS TRANSFERS Rules Applicable to Federal Assistance Programs Included in a Treasury-State Agreement § 205.20 What is a clearance pattern? States use clearance patterns to project when funds are paid...

  14. Assessment of the operating characteristics of the SSME LOX turbopump pump-end bearing

    NASA Technical Reports Server (NTRS)

    New, L. S.; Tiller, B. K.

    1984-01-01

    A bearing/shaft model of the SSME LOX turbopump was developed using the SHABERTH bearing/shaft math modeling computer code. A previously developed bearing/shaft thermal model of the SSME LOX turbopump turbine and bearing was used in conjunction with SHABERTH to evaluate the thermomechanical operating characteristics of the LOX turbopump end bearings. Results show that for the two unmounted diametrical clearances evaluated (4.0 mils and 6.3 mils), the inboard pump end bearing supports about 81% of the isolator load for the small clearance and 77% of the isolator load for the larger clearance. Bearing clearance changes due to thermal effects were 40% for the 4.0 mil diametrical clearance case and 19% for the 6.3 mil clearance case evaluated. The thermal analysis included evaluation of bearing temperatures for a subcooled case and a saturated case. Results indicate that no drastic temperature change occurred between the two cases. Since the rolling element and race surfaces of the subcooled case were at temperatures sufficiently high enough to be vapor blanketed, exceeding saturation temperature at the bearing inlet did not increase surface temperatures greatly.

  15. Aerodynamic analysis of Audi A4 Sedan using CFD

    NASA Astrophysics Data System (ADS)

    Birwa, S. K.; Rathi, N.; Gupta, R.

    2013-04-01

    This paper presents the aerodynamic influence of velocity and ground clearance for Audi A4 Sedan. The topology of the test vehicle was modeled using CATIA P3 V5 R17. ANSYS FLUENT 12 was the CFD solver employed in this study. The distribution of pressure and velocity was obtained. The velocities were 30, 40, 50 and 60 m/s and ground clearances were 76.2 mm,101.6 mm,127 mm and 152.4 mm. The simulation results were compared with the available resources. It was found that the drag coefficient decreases with the velocity increasing from 30 to 60 m/s and increases with the ground clearance from 101.6 mm to 152.4 mm. Further decrease in ground clearance showed no effect on the value of coefficient of drag. The lift coefficient was found to decrease firstly with ground clearance from 152.4 mm to 101.6 mm, and then increase from 101.6 mm to 76.2 mm. Both the lift coefficient and drag coefficient was found to be minimum for the ground clearance of 101.6 mm as designed by the company.

  16. Dialyzer performance in the clinic: comparison of six low-flux membranes.

    PubMed

    Kerr, P G; Lo, A; Chin, M m; Atkins, R C

    1999-09-01

    The aim of this study is to assess the clinical performance of 6 different low-flux dialysis membranes under steady-state conditions in terms of urea and phosphate clearances. Ten stable hemodialysis patients were examined. The following dialyzers were studied, all in 1.5- to 1.6-m2 format: cuprammonium, cellulose acetate, cellulose diacetate, hemophane, polysulfone (low-flux), and polysynthane. The following parameters were examined: urea reduction ratio, phosphate reduction ratio, "instantaneous dialyzer clearance" for urea and phosphate, and total amount of urea and phosphate removed in the dialysate over a 1-week (three dialyses) period. Although there were differences between the membranes, all produced results within a narrow range. There was no one membrane that produced superior clearances in all categories. The cellulose acetate membrane was the least satisfactory membrane. Phosphate clearances were at best one third that of urea clearances. When choosing a low-flux dialysis membrane, urea and phosphate clearances are so similar amongst different membranes that other criteria are likely to have a greater influence on the choice of membrane.

  17. Nano-Advantage in Enhanced Drug Delivery with Biodegradable Nanoparticles: Contribution of Reduced Clearance

    PubMed Central

    Kadam, Rajendra S.; Bourne, David W. A.

    2012-01-01

    The aim of this study was to investigate the contribution of reduced apparent clearance to the enhanced exposure reported for biodegradable nanoparticles after extravascular and intravascular routes of administration. Plasma concentration profiles for drug and nanoparticle formulations after administration by intravenous, intraduodenal, and oral routes were extracted from the literature. Data were fit to pharmacokinetic models using BOOMER. The compartmental pharmacokinetic analysis of literature data for six drugs (camptothecin, 9-nitrocamptothecin, epirubicin, vinpocetine, clozapine, and cyclosporine) showed that the encapsulation of drug molecules in nanoparticles significantly reduced the apparent clearance and prolonged the apparent circulation half-life compared with those for the plain drug. Positively charged nanoparticles assessed in this study had lower apparent clearance, lower elimination rate constant values, and longer apparent circulation half-life than neutral and negatively charged nanoparticles. After oral administration, a reduction in apparent clearance contributed substantially to elevations in plasma drug exposure with nanoparticles. For the drugs and delivery systems examined, the nano-advantage in drug delivery enhancement can be explained, in part, by reduced clearance. PMID:22498894

  18. Experimental studies on the effect of automation on pilot situational awareness in the datalink ATC environment

    NASA Technical Reports Server (NTRS)

    Hahn, Edward C.; Hansman, R. J., Jr.

    1992-01-01

    An experiment to study how automation, when used in conjunction with datalink for the delivery of ATC clearance amendments, affects the situational awareness of aircrews was conducted. The study was focused on the relationship of situational awareness to automated Flight Management System (FMS) programming of datalinked clearances and the readback of ATC clearances. Situational awareness was tested by issuing nominally unacceptable ATC clearances and measuring whether the error was detected by the subject pilots. The experiment also varied the mode of clearance delivery: Verbal, Textual, and Graphical. The error detection performance and pilot preference results indicate that the automated programming of the FMS may be superior to manual programming. It is believed that automated FMS programming may relieve some of the cognitive load, allowing pilots to concentrate on the strategic implications of a clearance amendment. Also, readback appears to have value, but the small sample size precludes a definite conclusion. Furthermore, because textual and graphical modes of delivery offer different but complementary advantages for cognitive processing, a combination of these modes of delivery may be advantageous in a datalink presentation.

  19. Nanoparticle-macrophage interactions: A balance between clearance and cell-specific targeting

    PubMed Central

    Rattan, Rahul; Bhattacharjee, Somnath; Zong, Hong; Swain, Corban; Siddiqui, Muneeb A.; Visovatti, Scott H.; Kanthi, Yogendra; Desai, Sajani; Pinsky, David J.; Goonewardena, Sascha N.

    2017-01-01

    The surface properties of nanoparticles (NPs) are a major factor that influences how these nanomaterials interact with biological systems. Interactions between NPs and macrophages of the reticuloendothelial system (RES) can reduce the efficacy of NP diagnostics and therapeutics. Traditionally, to limit NP clearance by the RES system, the NP surface is neutralized with molecules like poly(ethylene glycol) (PEG) which are known to resist protein adsorption and RES clearance. Unfortunately, PEG modification is not without drawbacks including difficulties with the synthesis and associations with immune reactions. To overcome some of these obstacles, we neutralized the NP surface by acetylation and compared this modification to PEGylation for RES clearance and tumor-specific targeting. We found that acetylation was comparable to PEGylation in reducing RES clearance. Additionally, we found that dendrimer acetylation did not impact folic acid (FA)-mediated targeting of tumor cells whereas PEG surface modification reduced the targeting ability of the NP. These results clarify the impact of different NP surface modifications on RES clearance and cell-specific targeting and provide insights into the design of more effective NPs. PMID:28705434

  20. Use of scintigraphy for the determination of mucociliary clearance rates in normal, sedated, diseased and exercised horses.

    PubMed Central

    Willoughby, R A; Ecker, G L; McKee, S L; Riddolls, L J

    1991-01-01

    Mucociliary clearance rates from the trachea were determined in normal, sedated, diseased and exercised horses from scintigraphs obtained after an injection of technetium-99m sulphide colloid into the tracheal lumen. The group mean tracheal clearance rate of eight clinically normal horses during 42 trials was 2.06 +/- 0.38 cm/min. Significant between horse differences were found (p less than 0.05). When six and seven of these horses were given xylazine and detomidine hydrochloride, respectively, mean group tracheal clearance rates dropped significantly (p less than 0.05). The decreases from each normal horse's mean tracheal clearance rate ranged from 18 to 54%. There did not appear to be a difference between the tracheal clearance rates (TCRs) of the normal horses and those with chronic respiratory disease. Postexercise evaluations were not significantly different from the pre-exercise TCRs in three clinically normal horses and three horses with chronic obstructive pulmonary disease (p greater than 0.05). This minimally invasive scintigraphic technique for determining TCRs has proved to be useful and reliable. Images Fig. 1. PMID:1790485

  1. Lung clearance of /sup 99m/Tc-DTPA in patients with acute lung injury and pulmonary edema

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coates, G.; O'Brodovich, H.; Dolovich, M.

    1988-07-01

    Several acute and chronic conditions that alter the integrity of the pulmonary epithelium increased the rate of absorption or clearance into the circulation of small solutes deposited in the alveoli. Technetium 99m diethylenetriamine pentaacetic acid can be deposited in the lungs as a submicronic aerosol and its rate of clearance measured with a gamma camera or simple probe. This clearance technique is currently being used to evaluate patients who have developed pulmonary edema and also to detect those patients from a high risk group who are likely to develop adult respiratory distress syndrome (ARDS). Its role in the evaluation ofmore » patients with pulmonary edema is still under active investigation. It is clear that a single measurement in patients who smoke is not useful, but repeated measurements may provide important information. The lung clearance measurement is very sensitive to changes in epithelial integrity but is not specific for ARDS. It may be most useful in combination with other predictive tests or when the clearance rate is normal. 54 references.« less

  2. Automatic Rail Extraction and Celarance Check with a Point Cloud Captured by Mls in a Railway

    NASA Astrophysics Data System (ADS)

    Niina, Y.; Honma, R.; Honma, Y.; Kondo, K.; Tsuji, K.; Hiramatsu, T.; Oketani, E.

    2018-05-01

    Recently, MLS (Mobile Laser Scanning) has been successfully used in a road maintenance. In this paper, we present the application of MLS for the inspection of clearance along railway tracks of West Japan Railway Company. Point clouds around the track are captured by MLS mounted on a bogie and rail position can be determined by matching the shape of the ideal rail head with respect to the point cloud by ICP algorithm. A clearance check is executed automatically with virtual clearance model laid along the extracted rail. As a result of evaluation, the accuracy of extracting rail positions is less than 3 mm. With respect to the automatic clearance check, the objects inside the clearance and the ones related to a contact line is successfully detected by visual confirmation.

  3. Adaptive Development

    NASA Technical Reports Server (NTRS)

    2005-01-01

    The goal of this research is to develop and demonstrate innovative adaptive seal technologies that can lead to dramatic improvements in engine performance, life, range, and emissions, and enhance operability for next generation gas turbine engines. This work is concentrated on the development of self-adaptive clearance control systems for gas turbine engines. Researchers have targeted the high-pressure turbine (HPT) blade tip seal location for following reasons: Current active clearance control (ACC) systems (e.g., thermal case-cooling schemes) cannot respond to blade tip clearance changes due to mechanical, thermal, and aerodynamic loads. As such they are prone to wear due to the required tight running clearances during operation. Blade tip seal wear (increased clearances) reduces engine efficiency, performance, and service life. Adaptive sealing technology research has inherent impact on all envisioned 21st century propulsion systems (e.g. distributed vectored, hybrid and electric drive propulsion concepts).

  4. Further Characterization of an Active Clearance Control Concept

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn C.; Steinetz, Bruce M.; Oswald, Jay J.

    2007-01-01

    A new test chamber and precision hydraulic actuation system were incorporated into an active clearance control (ACC) test rig at NASA Glenn Research Center. Using the improved system, a fast-acting, mechanically-actuated, ACC concept was evaluated at engine simulated temperatures and pressure differentials up to 1140 F and 120 psig, on the basis of secondary seal leakage and kinematic controllability. During testing, the ACC concept tracked a simulated flight clearance transient profile at 1140 F, 120 psig, with a maximum error of only 0.0012 in. Comparison of average dynamic leakage of the system with average static leakage did not show significant differences between the two operating conditions. Calculated effective clearance values for the rig were approximately 0.0002 in. at 120 psig, well below the industry specified effective clearance threshold of 0.001 in.

  5. Shear joint capability versus bolt clearance

    NASA Technical Reports Server (NTRS)

    Lee, H. M.

    1992-01-01

    The results of a conservative analysis approach into the determination of shear joint strength capability for typical space-flight hardware as a function of the bolt-hole clearance specified in the design are presented. These joints are comprised of high-strength steel fasteners and abutments constructed of aluminum alloys familiar to the aerospace industry. A general analytical expression was first arrived at which relates bolt-hole clearance to the bolt shear load required to place all joint fasteners into a shear transferring position. Extension of this work allowed the analytical development of joint load capability as a function of the number of fasteners, shear strength of the bolt, bolt-hole clearance, and the desired factor of safety. Analysis results clearly indicate that a typical space-flight hardware joint can withstand significant loading when less than ideal bolt hole clearances are used in the design.

  6. Accuracy of indocyanine green pulse spectrophotometry clearance test for liver function prediction in transplanted patients

    PubMed Central

    Hsieh, Chung-Bao; Chen, Chung-Jueng; Chen, Teng-Wei; Yu, Jyh-Cherng; Shen, Kuo-Liang; Chang, Tzu-Ming; Liu, Yao-Chi

    2004-01-01

    AIM: To investigate whether the non-invasive real-time Indocynine green (ICG) clearance is a sensitive index of liver viability in patients before, during, and after liver transplantation. METHODS: Thirteen patients were studied, two before, three during, and eight following liver transplantation, with two patients suffering acute rejection. The conventional invasive ICG clearance test and ICG pulse spectrophotometry non-invasive real-time ICG clearance test were performed simultaneously. Using linear regression analysis we tested the correlation between these two methods. The transplantation condition of these patients and serum total bilirubin (T. Bil), alanine aminotransferase (ALT), and platelet count were also evaluated. RESULTS: The correlation between these two methods was excellent (r2 = 0.977). CONCLUSION: ICG pulse spectrophotometry clearance is a quick, non-invasive, and reliable liver function test in transplantation patients. PMID:15285026

  7. Solute clearance measurement in the assessment of dialysis adequacy among African continuous ambulatory peritoneal dialysis patients.

    PubMed

    Abdu, Aliyu; Naidoo, Sagren; Malgas, Shirin; Naicker, Jocelyn T; Paget, Graham; Naicker, Saraladevi

    2015-01-01

    Solute clearance measurement is an objective means of quantifying the dose of peritoneal dialysis (PD). Despite continued debate on the interpretation and precise prognostic value of small solute clearance in PD patients, guidelines based on solute clearance values are common in clinical practice. There is limited information on the solute clearance indices and PD adequacy parameters among this predominantly low socioeconomic status PD population. We investigated the solute clearance among continuous ambulatory peritoneal dialysis (CAPD) patients at the Charlotte Maxeke Johannesburg Academic Hospital and its relationship with other parameters of PD adequacy. Seventy patients on CAPD were studied in this cross-sectional study. Solute clearance was assessed using urea clearance (Kt/V). Linear regression analysis was used to determine factors associated with solute clearance, while analysis of variance was used to test the influence of weekly Kt/V on blood pressure (BP), hemoglobin (Hb) and other biochemical parameters. The mean age of the study population was 37.9 ± 12.4 years, 43% were females and 86% were black Africans. The mean duration on CAPD was 19.7 ± 20.8 months. Mean systolic and diastolic BP were 144 ± 28 and 92 ± 17 mm Hg, respectively. The mean Hb was 11.1 ± 2.2 g/dL and the mean weekly Kt/V was 1.7 ± 0.3. Factors like systolic BP, Hb level, serum levels of cholesterol, calcium, phosphate, parathyroid hormone and albumin were not significantly associated with the weekly Kt/V. We conclude that the dose of PD received by the majority of our patients in terms of the weekly Kt/V is within the recommended values and that this finding is significant considering the low socioeconomic background of our patients. There is no significant association between Kt/V and other indices of dialysis adequacy.

  8. Early lactate clearance is associated with biomarkers of inflammation, coagulation, apoptosis, organ dysfunction and mortality in severe sepsis and septic shock

    PubMed Central

    2010-01-01

    Background Lactate clearance, a surrogate for the magnitude and duration of global tissue hypoxia, is used diagnostically, therapeutically and prognostically. This study examined the association of early lactate clearance with selected inflammatory, coagulation, apoptosis response biomarkers and organ dysfunction scores in severe sepsis and septic shock. Methods Measurements of serum arterial lactate, biomarkers (interleukin-1 receptor antagonist, interleukin-6, interleukin-8, interleukin-10, tumor necrosis factor-alpha, intercellular adhesion molecule-1, high mobility group box-1, D-Dimer and caspase-3), and organ dysfunction scores (Acute Physiology and Chronic Health Evaluation II, Simplified Acute Physiology Score II, Multiple Organ Dysfunction Score, and Sequential Organ Failure Assessment) were obtained in conjunction with a prospective, randomized study examining early goal-directed therapy in severe sepsis and septic shock patients presenting to the emergency department (ED). Lactate clearance was defined as the percent change in lactate levels after six hours from a baseline measurement in the ED. Results Two-hundred and twenty patients, age 65.0 +/- 17.1 years, were examined, with an overall lactate clearance of 35.5 +/- 43.1% and in-hospital mortality rate of 35.0%. Patients were divided into four quartiles of lactate clearance, -24.3 +/- 42.3, 30.1 +/- 7.5, 53.4 +/- 6.6, and 75.1 +/- 7.1%, respectively (p < 0.01). The mean levels of all biomarkers and organ dysfunction scores over 72 hours were significantly lower with higher lactate clearance quartiles (p < 0.01). There was a significant decreased in-hospital, 28-day, and 60-day mortality in the higher lactate clearance quartiles (p < 0.01). Conclusions Early lactate clearance as a surrogate for the resolution of global tissue hypoxia is significantly associated with decreased levels of biomarkers, improvement in organ dysfunction and outcome in severe sepsis and septic shock. PMID:20181046

  9. pH modulation and salivary sugar clearance of different chocolates in children: A randomized clinical trial.

    PubMed

    Nirmala, Svsg; Quadar, Mohammed Akhil; Veluru, Sindhuri

    2016-01-01

    Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate), filled (wafer and fruit and nuts chocolate), and candy (hard milk and mango-flavored candy) groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P < 0.05). Dark chocolate had a high fall in pH and milk chocolate had low salivary sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.

  10. Environmental factors affecting antipyrine metabolism in London factory and office workers.

    PubMed Central

    Fraser, H S; Mucklow, J C; Bulpitt, C J; Kahn, C; Mould, G; Dollery, C T

    1979-01-01

    1 Measurements of antipyrine clearance in saliva have been made in 128 London factory and office workers. 2 Mean antipyrine clearance in 56 Asian immigrants was 40% slower than in 72 White subjects. 3 Although dietary differences existed between the two groups, analysis of their effect independently of race was impossible since all but one of the vegetarians were Asian and the non-vegetarians were nearly all White. 4 In the White subjects, use of the oral contraceptive reduced clearance by 38% in women, while cigarette smoking increase clearance by 38% in men. PMID:427001

  11. Tip clearance effects on loads and performances of semi-open impeller centrifugal pumps at different specific speeds

    NASA Astrophysics Data System (ADS)

    Boitel, G.; Fedala, D.; Myon, N.

    2016-11-01

    Relevant industrial standards or customer's specifications could strictly forbid any device adjusting the axial rotor/stator position, so that tip clearance between semi-open impeller and casing might become a result of the pump machining tolerances and assembling process, leading to big tip clearance variations compared to its nominal value. Consequently, large disparities of global performances (head, power, efficiency) and axial loads are observed with high risk of both specifications noncompliance and bearing damages. This work aims at quantifying these variations by taking into account tip clearance value and pump specific speed. Computational Fluid Dynamics is used to investigate this phenomenon by means of steady simulations led on a semi-open centrifugal pump numerical model including secondary flows, based on a k-omega SST turbulence model. Four different specific speed pump sizes are simulated (from 8 to 50, SI units), with three tip clearances for each size on a wide flow range (from 40% to 120% of the best efficiency point). The numerical results clearly show that head, power and efficiency increase as the tip clearance decreases for the whole flow range. This effect is more significant when the specific speed is low. Meanwhile, the resulting axial thrust on the impeller is very sensitive to the tip clearance and can even lead to direction inversion.

  12. Comparison of trout hepatocytes and liver S9 fractions as in ...

    EPA Pesticide Factsheets

    Isolated hepatocytes and liver S9 fractions have been used to collect in vitro biotransformation data for fish as a means of improving modeled estimates of chemical bioaccumulation. To date, however, there have been few direct comparisons of these two methods. In the present study, cryopreserved trout hepatocytes were used to measure in vitro intrinsic clearance rates for 6 polycyclic aromatic hydrocarbons (PAHs). These rates were extrapolated to estimates of in vivo intrinsic clearance and used as inputs to a well-stirred liver model to predict hepatic clearance. Predicted rates of hepatic clearance were then evaluated by comparison to measured rates determined previously using isolated perfused livers. Hepatic clearance rates predicted using hepatocytes were in good agreement with measured values (< 2.1 fold difference for 5 of 6 compounds) under two competing binding assumptions. These findings, which may be attributed in part to high rates of PAH metabolism, are similar to those obtained previously using data from liver S9 fractions. For one compound (benzo[a]pyrene), the in vivo intrinsic clearance rate calculated using S9 data was 10-fold higher than that determined using hepatocytes, possibly due to a diffusion limitation on cellular uptake. Generally, however, there was good agreement between calculated in vivo intrinsic clearance rates obtained using either in vitro test system. These results suggest that both systems can be used to improve

  13. Investigation of the flow in the impeller side clearances of a centrifugal pump with volute casing

    NASA Astrophysics Data System (ADS)

    Will, Björn-Christian; Benra, Friedrich-Karl; Dohmen, Hans-Josef

    2012-06-01

    The paper is concerned with the fluid flow in the impeller side clearances of a centrifugal pump with volute casing. The flow conditions in these small axial gaps are of significant importance for a number of effects such as disk friction, leakage losses or hydraulic axial thrust to name but a few. In the investigated single stage pump, the flow pattern in the volute turns out to be asymmetric even at design flow rate. To gain a detailed insight into the flow structure, numerical simulations of the complete pump including the impeller side clearances are accomplished. Additionally, the hydraulic head and the radial pressure distributions in the impeller side clearances are measured and compared with the numerical results. Two configurations of the impeller, either with or without balancing holes, are examined. Moreover, three different operating points, i.e.: design point, part load or overload conditions are considered. In addition, analytical calculations are accomplished to determine the pressure distributions in the impeller side clearances. If accurate boundary conditions are available, the 1D flow models used in this paper can provide reasonable results for the radial static pressure distribution in the impeller side clearances. Furthermore, a counter rotating wake region develops in the rear impeller side clearances in absence of balancing holes which severely affects the inflow and outflow conditions of the cavity in circumferential direction.

  14. Domiciliary humidification improves lung mucociliary clearance in patients with bronchiectasis.

    PubMed

    Hasani, A; Chapman, T H; McCool, D; Smith, R E; Dilworth, J P; Agnew, J E

    2008-01-01

    Inspired air humidification has been reported to show some benefit in bronchiectatic patients. We have investigated the possibility that one effect might be to enhance mucociliary clearance. Such enhancement might, if it occurs, help to lessen the risks of recurrent infective episodes. Using a radioaerosol technique, we measured lung mucociliary clearance before and after 7 days of domiciliary humidification. Patients inhaled high flow saturated air at 37 degrees C via a patient-operated humidification nasal inhalation system for 3 h per day. We assessed tracheobronchial mucociliary clearance from the retention of (99m)Tc-labelled polystyrene tracer particles monitored for 6 h, with a follow-up 24-h reading. Ten out of 14 initially recruited patients (age 37-75 years; seven females) completed the study (two withdrew after their initial screening and two prior to the initial clearance test). Seven patients studied were non-smokers; three were ex-smokers (1-9 pack-years). Initial tracer radioaerosol distribution was closely similar between pre- and post-treatment. Following humidification, lung mucociliary clearance significantly improved, the area under the tracheobronchial retention curve decreased from 319 +/- 50 to 271 +/- 46%h (p < 0.07). Warm air humidification treatment improved lung mucociliary clearance in our bronchiectatic patients. Given this finding plus increasing laboratory and clinical interest in humidification mechanisms and effects, we believe further clinical trials of humidification therapy are desirable, coupled with analysis of humidification effects on mucus properties and transport.

  15. Depressed reticuloendothelial clearance of platelets in rats after trauma.

    PubMed

    Kaplan, J E; Moon, D G; Minnear, F L; Saba, T M

    1984-02-01

    Platelet microembolization may contribute to microcirculatory and organ damage following trauma and shock. It is hypothesized that posttraumatic reticuloendothelial depression predisposes to such microembolization by failure to clear altered platelets from the circulation. The present study evaluated the short-term (1 h) clearance and organ localization of radiolabeled homologous damaged platelets in normal rats and in rats following sublethal Noble-Collip drum trauma. Platelets were collected in citrated platelet-rich plasma from normal rats and labeled with 51Cr in citrated saline. Platelets were altered by repeated centrifugation in protein-free medium. These platelets differed functionally and morphologically from normal platelets. Disappearance of iv injected damaged platelets conformed to a two-compartment exponential clearance. Velocity of clearance in the rapid compartment correlated with hepatic platelet localization, whereas velocity of clearance in the second compartment correlated with splenic platelet localization. Clearance rate of the rapid compartment was depressed at 1 h after trauma and elevated at 24 h. These changes were associated with a decrease in hepatic platelet localization at 1 h and an increase above normal at 24 h. Splenic platelet localization was decreased by 3 h following trauma. Pulmonary platelet localization was increased at all times following trauma. It is concluded that the posttrauma state is associated with a defect in the reticuloendothelial system clearance of altered platelets, which may augment embolization of platelets in the lung.

  16. Physiological and Microfluorometric Studies of Reduction and Clearance of Retinal in Bleached Rod Photoreceptors

    PubMed Central

    Tsina, Efthymia; Chen, Chunhe; Koutalos, Yiannis; Ala-Laurila, Petri; Tsacopoulos, Marco; Wiggert, Barbara; Crouch, Rosalie K.; Cornwall, M. Carter

    2004-01-01

    The visual cycle comprises a sequence of reactions that regenerate the visual pigment in photoreceptors during dark adaptation, starting with the reduction of all-trans retinal to all-trans retinol and its clearance from photoreceptors. We have followed the reduction of retinal and clearance of retinol within bleached outer segments of red rods isolated from salamander retina by measuring its intrinsic fluorescence. Following exposure to a bright light (bleach), increasing fluorescence intensity was observed to propagate along the outer segments in a direction from the proximal region adjacent to the inner segment toward the distal tip. Peak retinol fluorescence was achieved after ∼30 min, after which it declined very slowly. Clearance of retinol fluorescence is considerably accelerated by the presence of the exogenous lipophilic substances IRBP (interphotoreceptor retinoid binding protein) and serum albumin. We have used simultaneous fluorometric and electrophysiological measurements to compare the rate of reduction of all-trans retinal to all-trans retinol to the rate of recovery of flash response amplitude in these cells in the presence and absence of IRBP. We find that flash response recovery in rods is modestly accelerated in the presence of extracellular IRBP. These results suggest such substances may participate in the clearance of retinoids from rod photoreceptors, and that this clearance, at least in rods, may facilitate dark adaptation by accelerating the clearance of photoproducts of bleaching. PMID:15452202

  17. Methodological uncertainty in quantitative prediction of human hepatic clearance from in vitro experimental systems.

    PubMed

    Hallifax, D; Houston, J B

    2009-03-01

    Mechanistic prediction of unbound drug clearance from human hepatic microsomes and hepatocytes correlates with in vivo clearance but is both systematically low (10 - 20 % of in vivo clearance) and highly variable, based on detailed assessments of published studies. Metabolic capacity (Vmax) of commercially available human hepatic microsomes and cryopreserved hepatocytes is log-normally distributed within wide (30 - 150-fold) ranges; Km is also log-normally distributed and effectively independent of Vmax, implying considerable variability in intrinsic clearance. Despite wide overlap, average capacity is 2 - 20-fold (dependent on P450 enzyme) greater in microsomes than hepatocytes, when both are normalised (scaled to whole liver). The in vitro ranges contrast with relatively narrow ranges of clearance among clinical studies. The high in vitro variation probably reflects unresolved phenotypical variability among liver donors and practicalities in processing of human liver into in vitro systems. A significant contribution from the latter is supported by evidence of low reproducibility (several fold) of activity in cryopreserved hepatocytes and microsomes prepared from the same cells, between separate occasions of thawing of cells from the same liver. The large uncertainty which exists in human hepatic in vitro systems appears to dominate the overall uncertainty of in vitro-in vivo extrapolation, including uncertainties within scaling, modelling and drug dependent effects. As such, any notion of quantitative prediction of clearance appears severely challenged.

  18. Renal Clearance: Using an Interactive Activity to Visualize a Tricky Concept

    ERIC Educational Resources Information Center

    Hull, Kerry

    2016-01-01

    Renal clearance, the volume of blood cleared of a substance in a particular time period, is commonly recognized as one of the most difficult concepts in physiology. This difficulty may in part reflect the quantitative nature of renal clearance since many life sciences majors perceive that mathematics is irrelevant to their discipline. Students may…

  19. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  20. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 3 2013-04-01 2013-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  1. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  2. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 3 2012-04-01 2012-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  3. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 3 2014-04-01 2014-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  4. 31 CFR 205.12 - What funding techniques may be used?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... that the State pays out each day. The projected amount paid out each day is determined by applying a clearance pattern to the total amount the State will disburse. (3) Average clearance means that a Federal Program Agency, on the dollar-weighted average day of clearance of a disbursement, transfers to a State a...

  5. Aerial Refueling Clearance Initiation Request

    DTIC Science & Technology

    2016-07-14

    and receiver agencies. The AR Clearance Initiation Request document recognizes the requirement for definitive aerial refueling agreements between...and contractual tanker support requests from one organization or nation to another. The AR Clearance Initiation Request document is not intended to...proprietary, sensitive, classified or otherwise restricted information. ARSAG documents, as prepared, are not DOD, MOD or NATO standards, but provide

  6. 14 CFR 105.17 - Flight visibility and clearance from cloud requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...

  7. 14 CFR 105.17 - Flight visibility and clearance from cloud requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...

  8. 14 CFR 105.17 - Flight visibility and clearance from cloud requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...

  9. 14 CFR 105.17 - Flight visibility and clearance from cloud requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...

  10. 14 CFR 105.17 - Flight visibility and clearance from cloud requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...

  11. The effects of alcohol on spontaneous clearance of acute hepatitis C virus infection in females versus males.

    PubMed

    Tsui, Judith I; Mirzazadeh, Ali; Hahn, Judith A; Maher, Lisa; Bruneau, Julie; Grebely, Jason; Hellard, Margaret; Kim, Arthur Y; Shoukry, Naglaa H; Cox, Andrea L; Prins, Maria; Dore, Gregory J; Lauer, Georg; Lloyd, Andrew R; Page, Kimberly

    2016-12-01

    Approximately one quarter of persons exposed to hepatitis C virus (HCV) will spontaneously clear infection. We undertook this study to investigate the impact of alcohol on likelihood of HCV spontaneous viral clearance stratified by sex groups. Pooled data from an international collaboration of prospective observational studies of incident HIV and HCV infection in high-risk cohorts (the InC3 Study) was restricted to 411 persons (or 560.7 person-years of observation) with documented acute HCV infection and data regarding alcohol use. The predictor of interest was self-reported alcohol use at or after estimated date of incident HCV infection and the outcome was HCV spontaneous clearance. Sex stratified Cox proportional hazards models were used to evaluate the association between alcohol and spontaneous clearance, adjusting for age, race/ethnicity, and IFNL4 genotype. The median age was 28.5 years, 30.4% were women, 87.2% were white, and 71.8% reported alcohol use at or after incident infection. There were 89 (21.6%) cases of spontaneous clearance observed, 39 (31.2%) among women and 50 (17.5%) in men (p<0.01). Overall, spontaneous clearance occurred less frequently among participants who drank alcohol compared to those who did not drink (18.9% v. 28.5%, p=0.03). After adjustment for other covariates, alcohol was significantly and independently associated with lower relative hazards for spontaneous clearance of HCV in women (AHR=0.35; 95% CI: 0.19-0.66; p=0.001) but not in men (AHR=0.63; 95% CI: 0.36-1.09; p=0.10). Results indicate that abstaining from drinking alcohol may increase the likelihood of spontaneous clearance among women. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. The Effects of Alcohol on Spontaneous Clearance of Acute Hepatitis C Virus Infection in Females versus Males

    PubMed Central

    Tsui, Judith I.; Mirzazadeh, Ali; Hahn, Judith A.; Maher, Lisa; Bruneau, Julie; Grebely, Jason; Hellard, Margaret; Kim, Arthur Y.; Shoukry, Naglaa H.; Cox, Andrea L.; Prins, Maria; Dore, Gregory; Lauer, Georg; Lloyd, Andrew; Page, Kimberly

    2016-01-01

    Background Approximately one quarter of persons exposed to hepatitis C virus (HCV) will spontaneously clear infection. We undertook this study to investigate the impact of alcohol on likelihood of HCV spontaneous viral clearance stratified by sex groups. Methods Pooled data from an international collaboration of prospective observational studies of incident HIV and HCV infection in high-risk cohorts (the InC3 Study) was restricted to 411 persons (or 560.7 person-years of observation) with documented acute HCV infection and data regarding alcohol use. The predictor of interest was self-reported alcohol use at or after estimated date of incident HCV infection and the outcome was HCV spontaneous clearance. Sex stratified Cox proportional hazards models were used to evaluate the association between alcohol and spontaneous clearance, adjusting for age, race/ethnicity, and IFNL4 genotype. Results The median age was 28.5 years, 30.4% were women, 87.2% were white, and 71.8% reported alcohol use at or after incident infection. There were 89 (21.6%) cases of spontaneous clearance observed, 39 (31.2%) among women and 50 (17.5%) in men (p<0.01). Overall, spontaneous clearance occurred less frequently among participants who drank alcohol compared to those who did not drink (18.9% v. 28.5%, p=0.03). After adjustment for other covariates, alcohol was significantly and independently associated with lower relative hazards for spontaneous clearance of HCV in women (AHR=0.35; 95% CI: 0.19-0.66; p=0.001) but not in men (AHR=0.63; 95% CI: 0.36-1.09; p=0.10). Conclusion Results indicate that abstaining from drinking alcohol may increase the likelihood of spontaneous clearance among women. PMID:27816863

  13. Long-term clearance from small airways in subjects with ciliary dysfunction.

    PubMed

    Lindström, Maria; Falk, Rolf; Hjelte, Lena; Philipson, Klas; Svartengren, Magnus

    2006-05-20

    The objective of this study was to investigate if long-term clearance from small airways is dependent on normal ciliary function. Six young adults with primary ciliary dyskinesia (PCD) inhaled 111 Indium labelled Teflon particles of 4.2 microm geometric and 6.2 microm aerodynamic diameter with an extremely slow inhalation flow, 0.05 L/s. The inhalation method deposits particles mainly in the small conducting airways. Lung retention was measured immediately after inhalation and at four occasions up to 21 days after inhalation. Results were compared with data from ten healthy controls. For additional comparison three of the PCD subjects also inhaled the test particles with normal inhalation flow, 0.5 L/s, providing a more central deposition. The lung retention at 24 h in % of lung deposition (Ret24) was higher (p < 0.001) in the PCD subjects, 79 % (95% Confidence Interval, 67.6;90.6), compared to 49% (42.3;55.5) in the healthy controls. There was a significant clearance after 24 h both in the PCD subjects and in the healthy controls with equivalent clearance. The mean Ret24 with slow inhalation flow was 73.9 +/- 1.9% compared to 68.9 +/- 7.5% with normal inhalation flow in the three PCD subjects exposed twice. During day 7-21 the three PCD subjects exposed twice cleared 9% with normal flow, probably representing predominantly alveolar clearance, compared to 19% with slow inhalation flow, probably representing mainly small airway clearance. This study shows that despite ciliary dysfunction, clearance continues in the small airways beyond 24 h. There are apparently additional clearance mechanisms present in the small airways.

  14. Noncontact Capacitive Clearance Control System For Laser Cutting Machines

    NASA Astrophysics Data System (ADS)

    Topkaya, Ahmet; Schmall, Karl-Heinz; Majoli, Ralf

    1989-03-01

    For a continuous high quality laser cut, it is necessary among other things to position the focal point of the laser beam correctly. This means that a constant clearance between the cutting head and the workpiece with a tolerance of +/- 0.Imm must he ensured. When cutting corrugated automobile bodysheet for example, a good quality cut can only be achieved with automatic clearance control. In the following, a method of automatic clearance control is described using the assistance of a noncontact capacitive sensor system. The copper nozzle of the laser cutting head acts as the electrode of the clearance sensor. The nozzle electrode and the workpiece build a small variable capacitance depending on the clearance. A change of clearance also changes the capacitance, which in turn influences a high frequency oscillator circuit. This shift in frequency is then converted into an analogue DC signal, which can be used to operate a servo motor control for the positioning of the laser cutting head in a closed loop servo system. Laser cutting heads with clearance sensor nozzles of different shapes, suited fur most applications in the industry, with focal lengths from 2.5" to 5" have been developed. They are capable to cut metal sheet from 0.2 to 12 mm of thickness, using CO2-lasers with output power up to 2.5 kW. For special applications involving difficult workpiece topographies in automobile production applications special "trunk" nozzles have been developed. For 5-axis cutting machines and robots, new laser cutting heads with integrated nozzle sensors in combination with a high dynamic Z-axis motor drive are in a stage of development.

  15. Inhibition of cytochrome P450 enzymes by saturated and unsaturated fatty acids in human liver microsomes, characterization of enzyme kinetics in the presence of bovine serum albumin (0.1 and 1.0% w/v) and in vitro - in vivo extrapolation of hepatic clearance.

    PubMed

    Palacharla, Raghava Choudary; Uthukam, Venkatesham; Manoharan, Arunkumar; Ponnamaneni, Ranjith Kumar; Padala, Nagasurya Prakash; Boggavarapu, Rajesh Kumar; Bhyrapuneni, Gopinadh; Ajjala, Devender Reddy; Nirogi, Ramakrishna

    2017-04-01

    The objective of the study was to determine the effect of fatty acids on CYP enzymes and the effect of BSA on intrinsic clearance of probe substrates. The inhibitory effect of thirteen fatty acids including saturated, mono-unsaturated and polyunsaturated fatty acids on CYP enzymes, kinetic parameters and intrinsic clearance values of nine CYP marker probe substrate reactions in the absence and presence of BSA (0.1 and 1.0% w/v) were characterized in human liver microsomes. The results demonstrate that most of the unsaturated fatty acids showed marked inhibition towards CYP2C8 mediated amodiaquine N-deethylation followed by inhibition of CYP2C9 and CYP2B6 mediated activities. The addition of 0.1% BSA in the incubation markedly improved the unbound intrinsic clearance values of probe substrates by reducing the K m values with little or no effect on maximal velocity. The addition of BSA (0.1 and 1.0% w/v) did not influence the unbound intrinsic clearance of marker reactions for CYP2A6, and CYP3A4 enzymes. The addition of 0.1% w/v BSA is sufficient to determine the intrinsic clearance of marker probe reactions by metabolite formation approach. The predicted hepatic clearance values for the substrates using the well-stirred model, in the presence of BSA (0.1% BSA), are comparable to the in vivo hepatic clearance values. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. The effect of pregnancy on renal clearance of boron in rats given boric acid orally.

    PubMed

    Vaziri, N D; Oveisi, F; Culver, B D; Pahl, M V; Andersen, M E; Strong, P L; Murray, F J

    2001-04-01

    Boric acid (H(3)BO(3)) has been shown to cause developmental abnormalities in the offspring of pregnant rats. Comparative data on the renal clearance of boron (B) in rats and humans, both pregnant and nonpregnant, exposed to boric acid (BA) would reduce uncertainty in interspecies extrapolation from rats to humans. The purpose of this study was to evaluate the effect of pregnancy on the plasma half-life and renal clearance of boron in Sprague-Dawley rats given a single oral dose of boric acid. For the half-life study, nonpregnant and pregnant (gestation day 16) rats were given a single dose of 30 mg/kg of boric acid by gavage, and plasma samples were collected at 2-3 h intervals. The plasma half-life of boron was determined to be 2.9 +/- 0.2 and 3.2 +/- 0.3 h in nonpregnant and pregnant rats, respectively. In the clearance study, nonpregnant and pregnant (GD 16) rats were given a single gavage dose of 0.3, 3, or 30 mg/kg of boric acid. Boron clearance was slightly higher in pregnant rats (3.3 +/- 0.6, 3.2 +/- 0.5, and 3.4 +/- 0.5 ml/min/kg, respectively) compared to nonpregnant rats (3.1 +/- 0.8, 3.0 +/- 0.6, and 3.2 +/- 0.5 ml/min/kg, respectively), but the difference was not statistically significant and not dose-related. Boron clearance was less than creatinine clearance, suggesting tubular reabsorption in both groups. In conclusion, pregnancy did not appear to significantly alter the renal clearance or the plasma half-life of boron in Sprague-Dawley rats under the conditions of this study.

  17. Pre-Departure Clearance (PDC): An Analysis of Aviation Safety Reporting System Reports Concerning PDC Related Errors

    NASA Technical Reports Server (NTRS)

    Montalyo, Michael L.; Lebacqz, J. Victor (Technical Monitor)

    1994-01-01

    Airlines operating in the United States are required to operate under instrument flight rules (EFR). Typically, a clearance is issued via voice transmission from clearance delivery at the departing airport. In 1990, the Federal Aviation Administration (FAA) began deployment of the Pre-Departure Clearance (PDC) system at 30 U.S. airports. The PDC system utilizes aeronautical datalink and Aircraft Communication and Reporting System (ACARS) to transmit departure clearances directly to the pilot. An objective of the PDC system is to provide an immediate reduction in voice congestion over the clearance delivery frequency. Participating airports report that this objective has been met. However, preliminary analysis of 42 Aviation Safety Reporting System (ASRS) reports has revealed problems in PDC procedures and formatting which have caused errors in the proper execution of the clearance. It must be acknowledged that this technology, along with other advancements on the flightdeck, is adding more responsibility to the crew and increasing the opportunity for error. The present study uses these findings as a basis for further coding and analysis of an additional 82 reports obtained from an ASRS database search. These reports indicate that clearances are often amended or exceptions are added in order to accommodate local ATC facilities. However, the onboard ACARS is limited in its ability to emphasize or highlight these changes which has resulted in altitude and heading deviations along with increases in ATC workload. Furthermore, few participating airports require any type of PDC receipt confirmation. In fact, 35% of all ASRS reports dealing with PDC's include failure to acquire the PDC at all. Consequently, this study examines pilots' suggestions contained in ASRS reports in order to develop recommendations to airlines and ATC facilities to help reduce the amount of incidents that occur.

  18. Clinical evaluation of plasma insulin and C-peptide levels with 3 different high-flux dialyzers in diabetic patients on hemodialysis.

    PubMed

    Abe, M; Okada, K; Maruyama, T; Inoshita, A; Ikeda, K; Uto, E; Kikuchi, F; Matsumoto, K

    2008-10-01

    Changes in plasma immunoreactive insulin (IRI) and connecting-peptide immunoreactivity (CPR) concentrations during hemodialysis (HD) were evaluated in diabetic HD patients with 3 different high-flux membranes. The removal properties of the membranes were compared. In this prospective controlled study, 15 stable diabetic patients on HD were randomly selected for 6 HD sessions with 3 different membranes: polysulfone (PS), cellulose triacetate (CTA), and polymethylmethacrylate (PMMA). Blood samples were obtained from the blood tubing at the arterial (A) site at the beginning and end of the sixth HD session. At 60 minutes after dialysis initiation, blood samples were obtained from both the A and venous (V) sites of the dialyzer to investigate the clearance and removal properties of the membranes. The plasma IRI and CPR levels decreased significantly at each time point with all 3 membranes. IRI clearance with the PS membrane was significantly higher than that with the CTA and PMMA membranes. No difference was observed in the IRI reduction rate between the 3 membranes. CPR clearance and reduction rate with the PMMA membrane were lower than with the PS and CTA membranes. No significant difference was observed in serum creatinine clearance and reduction rates between the 3 membranes; however, serum urea nitrogen clearance was significantly lower with the PMMA membrane compared with the PS and CTA membranes. A significantly high beta2-microglobulin clearance and reduction rate was achieved in the order PS > CTA > PMMA. Plasma IRI and CPR are cleared by HD; their clearance rates differ with the dialyzer membranes. Plasma IRI clearance with the PS membrane is higher than that with the CTA and PMMA membranes.

  19. Depression of in vivo clearance function of hepatic macrophage complement receptors following thermal injury.

    PubMed

    Cuddy, B G; Loegering, D J; Blumenstock, F A

    1984-09-01

    Previous studies have implicated a role for impaired hepatic macrophage blood clearance function in the increased susceptibility to infection caused by experimental thermal injury. The present study evaluated in vivo hepatic macrophage complement receptor clearance function as a possible factor contributing to impaired hepatic clearance after thermal injury. Rat erythrocytes treated with anti-erythrocyte serum (EA) were used as the test particle in rats. EA were rapidly removed from the circulation primarily by the liver and hepatic uptake of EA was greatly depressed in animals rendered C3 deficient by treatment with cobra venom factor. Thermal injury caused a large depression in the hepatic uptake of EA. It was shown that the depression in the binding of EA to hepatic macrophages was not due to decreased hepatic blood flow, decreased serum complement levels, or increased fluid phase C3b. Also, the depression of the hepatic uptake of EA incubated with serum prior to injection (EAC) was not different from that of EA after thermal injury. On this basis it was concluded that the impairment in binding of EA to the macrophages was at the cellular level and represented a depression in complement receptor clearance function. Additional studies showed that the injection of erythrocyte stroma, as a model of intravascular hemolysis, also depressed in vivo hepatic macrophage complement receptor clearance function. This latter finding suggests that the intravascular hemolysis caused by thermal injury may contribute to the depression of macrophage receptor function. The depression of hepatic macrophage complement receptor clearance function may contribute to the impaired bacterial clearance and increased susceptibility to infection following experimental thermal injury.

  20. Pharmacokinetics of amoxycillin and clavulanic acid in haemodialysis patients following intravenous administration of Augmentin.

    PubMed Central

    Davies, B E; Boon, R; Horton, R; Reubi, F C; Descoeudres, C E

    1988-01-01

    1. Serum concentrations of amoxycillin and clavulanic acid were measured in patients with end-stage renal disease (ESRD) following intravenous administration of 1.2 g Augmentin. Augmentin was administered on a non-dialysis day and 2 h prior to a 4 h dialysis session. 2. The mean values of total serum clearance, mean residence time, volume of distribution at steady state, and terminal half-life for amoxycillin on the non-dialysis day were 14.4 ml min-1, 19.2 h, 14.9 l and 13.6 h, respectively. 3. The mean values of dialysis clearance, total serum clearance during dialysis, fractional drug removal during haemodialysis and half-life during dialysis for amoxycillin were 77.1 ml min-1, 91.5 ml min-1, 0.64 and 2.30 h, respectively. 4. The mean values of total serum clearance, mean residence time, volume of distribution at steady state, and terminal half-life for clavulanic acid on the non-dialysis day were 43.6 ml min-1, 4.4 h, 11.0 l and 3.05 h, respectively. 5. The mean values of dialysis clearance, total serum clearance during dialysis, fractional drug removal during haemodialysis and half-life during dialysis for clavulanic acid were 92.8 ml min-1, 136 ml min-1, 0.65 and 1.19 h, respectively. 6. The total serum clearance on the non-dialysis day, which represents non-renal clearance, was lower than that in normal subjects for both amoxycillin and clavulanic acid. These data would suggest some degree of hepatic impairment in patients with ESRD.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3190988

  1. Nasal high flow clears anatomical dead space in upper airway models

    PubMed Central

    Celik, Gülnaz; Feng, Sheng; Bartenstein, Peter; Meyer, Gabriele; Eickelberg, Oliver; Schmid, Otmar; Tatkov, Stanislav

    2015-01-01

    Recent studies showed that nasal high flow (NHF) with or without supplemental oxygen can assist ventilation of patients with chronic respiratory and sleep disorders. The hypothesis of this study was to test whether NHF can clear dead space in two different models of the upper nasal airways. The first was a simple tube model consisting of a nozzle to simulate the nasal valve area, connected to a cylindrical tube to simulate the nasal cavity. The second was a more complex anatomically representative upper airway model, constructed from segmented CT-scan images of a healthy volunteer. After filling the models with tracer gases, NHF was delivered at rates of 15, 30, and 45 l/min. The tracer gas clearance was determined using dynamic infrared CO2 spectroscopy and 81mKr-gas radioactive gamma camera imaging. There was a similar tracer-gas clearance characteristic in the tube model and the upper airway model: clearance half-times were below 1.0 s and decreased with increasing NHF rates. For both models, the anterior compartments demonstrated faster clearance levels (half-times < 0.5 s) and the posterior sections showed slower clearance (half-times < 1.0 s). Both imaging methods showed similar flow-dependent tracer-gas clearance in the models. For the anatomically based model, there was complete tracer-gas removal from the nasal cavities within 1.0 s. The level of clearance in the nasal cavities increased by 1.8 ml/s for every 1.0 l/min increase in the rate of NHF. The study has demonstrated the fast-occurring clearance of nasal cavities by NHF therapy, which is capable of reducing of dead space rebreathing. PMID:25882385

  2. Rare versus common variants in pharmacogenetics: SLCO1B1 variation and methotrexate disposition

    PubMed Central

    Ramsey, Laura B.; Bruun, Gitte H.; Yang, Wenjian; Treviño, Lisa R.; Vattathil, Selina; Scheet, Paul; Cheng, Cheng; Rosner, Gary L.; Giacomini, Kathleen M.; Fan, Yiping; Sparreboom, Alex; Mikkelsen, Torben S.; Corydon, Thomas J.; Pui, Ching-Hon; Evans, William E.; Relling, Mary V.

    2012-01-01

    Methotrexate is used to treat autoimmune diseases and malignancies, including acute lymphoblastic leukemia (ALL). Inter-individual variation in clearance of methotrexate results in heterogeneous systemic exposure, clinical efficacy, and toxicity. In a genome-wide association study of children with ALL, we identified SLCO1B1 as harboring multiple common polymorphisms associated with methotrexate clearance. The extent of influence of rare versus common variants on pharmacogenomic phenotypes remains largely unexplored. We tested the hypothesis that rare variants in SLCO1B1 could affect methotrexate clearance and compared the influence of common versus rare variants in addition to clinical covariates on clearance. From deep resequencing of SLCO1B1 exons in 699 children, we identified 93 SNPs, 15 of which were non-synonymous (NS). Three of these NS SNPs were common, with a minor allele frequency (MAF) >5%, one had low frequency (MAF 1%–5%), and 11 were rare (MAF <1%). NS SNPs (common or rare) predicted to be functionally damaging were more likely to be found among patients with the lowest methotrexate clearance than patients with high clearance. We verified lower function in vitro of four SLCO1B1 haplotypes that were associated with reduced methotrexate clearance. In a multivariate stepwise regression analysis adjusting for other genetic and non-genetic covariates, SLCO1B1 variants accounted for 10.7% of the population variability in clearance. Of that variability, common NS variants accounted for the majority, but rare damaging NS variants constituted 17.8% of SLCO1B1's effects (1.9% of total variation) and had larger effect sizes than common NS variants. Our results show that rare variants are likely to have an important effect on pharmacogenetic phenotypes. PMID:22147369

  3. Clearance detector and method for motion and distance

    DOEpatents

    Xavier, Patrick G [Albuquerque, NM

    2011-08-09

    A method for correct and efficient detection of clearances between three-dimensional bodies in computer-based simulations, where one or both of the volumes is subject to translation and/or rotations. The method conservatively determines of the size of such clearances and whether there is a collision between the bodies. Given two bodies, each of which is undergoing separate motions, the method utilizes bounding-volume hierarchy representations for the two bodies and, mappings and inverse mappings for the motions of the two bodies. The method uses the representations, mappings and direction vectors to determine the directionally furthest locations of points on the convex hulls of the volumes virtually swept by the bodies and hence the clearance between the bodies, without having to calculate the convex hulls of the bodies. The method includes clearance detection for bodies comprising convex geometrical primitives and more specific techniques for bodies comprising convex polyhedra.

  4. Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor

    NASA Astrophysics Data System (ADS)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2012-08-01

    Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.

  5. Dual roles for hepatic lectin receptors in the clearance of chilled platelets.

    PubMed

    Rumjantseva, Viktoria; Grewal, Prabhjit K; Wandall, Hans H; Josefsson, Emma C; Sørensen, Anne Louise; Larson, Göran; Marth, Jamey D; Hartwig, John H; Hoffmeister, Karin M

    2009-11-01

    Rapid chilling causes glycoprotein-Ib (GPIb) receptors to cluster on blood platelets. Hepatic macrophage beta(2) integrin binding to beta-N-acetylglucosamine (beta-GlcNAc) residues in the clusters leads to rapid clearance of acutely chilled platelets after transfusion. Although capping the beta-GlcNAc moieties by galactosylation prevents clearance of short-term-cooled platelets, this strategy is ineffective after prolonged refrigeration. We report here that prolonged refrigeration increased the density and concentration of exposed galactose residues on platelets such that hepatocytes, through Ashwell-Morell receptor binding, become increasingly involved in platelet removal. Macrophages rapidly removed a large fraction of transfused platelets independent of their storage conditions. With prolonged platelet chilling, hepatocyte-dependent clearance further diminishes platelet recovery and survival after transfusion. Inhibition of chilled platelet clearance by both beta(2) integrin and Ashwell-Morell receptors may afford a potentially simple method for storing platelets in the cold.

  6. Interspecies scaling and prediction of human clearance: comparison of small- and macro-molecule drugs

    PubMed Central

    Huh, Yeamin; Smith, David E.; Feng, Meihau Rose

    2014-01-01

    Human clearance prediction for small- and macro-molecule drugs was evaluated and compared using various scaling methods and statistical analysis.Human clearance is generally well predicted using single or multiple species simple allometry for macro- and small-molecule drugs excreted renally.The prediction error is higher for hepatically eliminated small-molecules using single or multiple species simple allometry scaling, and it appears that the prediction error is mainly associated with drugs with low hepatic extraction ratio (Eh). The error in human clearance prediction for hepatically eliminated small-molecules was reduced using scaling methods with a correction of maximum life span (MLP) or brain weight (BRW).Human clearance of both small- and macro-molecule drugs is well predicted using the monkey liver blood flow method. Predictions using liver blood flow from other species did not work as well, especially for the small-molecule drugs. PMID:21892879

  7. Control means for a gas turbine engine

    NASA Technical Reports Server (NTRS)

    Beitler, R. S.; Sellers, F. J.; Bennett, G. W. (Inventor)

    1982-01-01

    A means is provided for developing a signal representative of the actual compressor casing temperature, a second signal representative of compressor inlet gas temperature, and a third signal representative of compressor speed. Another means is provided for receiving the gas temperature and compressor speed signals and developing a schedule output signal which is a representative of a reference casing temperature at which a predetermined compressor blade stabilized clearance is provided. A means is also provided for comparing the actual compressor casing temperature signal and the reference casing temperature signal and developing a clearance control system representative of the difference. The clearance control signal is coupled to a control valve which controls a flow of air to the compressor casing to control the clearance between the compressor blades and the compressor casing. The clearance control signal can be modified to accommodate transient characteristics. Other embodiments are disclosed.

  8. Role of genetic variation in docetaxel-induced neutropenia and pharmacokinetics.

    PubMed

    Nieuweboer, A J M; Smid, M; de Graan, A-J M; Elbouazzaoui, S; de Bruijn, P; Eskens, F A L M; Hamberg, P; Martens, J W M; Sparreboom, A; de Wit, R; van Schaik, R H N; Mathijssen, R H J

    2016-11-01

    Docetaxel is used for treatment of several solid malignancies. In this study, we aimed for predicting docetaxel clearance and docetaxel-induced neutropenia by developing several genetic models. Therefore, pharmacokinetic data and absolute neutrophil counts (ANCs) of 213 docetaxel-treated cancer patients were collected. Next, patients were genotyped for 1936 single nucleotide polymorphisms (SNPs) in 225 genes using the drug-metabolizing enzymes and transporters platform and thereafter split into two cohorts. The combination of SNPs that best predicted severe neutropenia or low clearance was selected in one cohort and validated in the other. Patients with severe neutropenia had lower docetaxel clearance than patients with ANCs in the normal range (P=0.01). Severe neutropenia was predicted with 70% sensitivity. True low clearance (1 s.d.

  9. Ginsenoside compound K promotes β-amyloid peptide clearance in primary astrocytes via autophagy enhancement.

    PubMed

    Guo, Jinhui; Chang, Li; Zhang, Xin; Pei, Sujuan; Yu, Meishuang; Gao, Jianlian

    2014-10-01

    The aim of the present study was to investigate the effect of ginsenoside compound K on β-amyloid (Aβ) peptide clearance in primary astrocytes. Aβ degradation in primary astrocytes was determined using an intracellular Aβ clearance assay. Aggregated LC3 in astrocyte cells, which is a marker for the level of autophagy, was detected using laser scanning confocal microscope. The effect of compound K on the mammalian target of rapamycin (mTOR)/autophagy pathway was determined using western blot analysis, and an enzyme-linked immunosorbent assay was used for Aβ detection. The results demonstrated that compound K promoted the clearance of Aβ and enhanced autophagy in primary astrocytes. In addition, it was found that phosphorylation of mTOR was inhibited by compound K, which may have contributed to the enhanced autophagy. In conclusion, compound K promotes Aβ clearance by enhancing autophagy via the mTOR signaling pathway in primary astrocytes.

  10. The effect of ranitidine on the plasma clearance and hepatic extraction of indocyanine green in patients with chronic liver disease.

    PubMed Central

    Dunk, A A; Jenkins, W J; Burroughs, A K; Walt, R P; Osuafor, T O; Sherlock, S; Mackie, S; Dick, R

    1983-01-01

    Since hepatic clearance of ICG is reduced by H2-receptor antagonists in normal subjects, it has been suggested that they reduce liver blood flow. We have studied the effect of intravenous ranitidine on ICG clearance in twelve patients with chronic liver disease. Wedged and free hepatic venous pressure were measured before and after intravenous ranitidine in nine of the patients, and the hepatic extraction of ICG was determined in six patients. ICG clearance fell by 22 +/- 11% (s.e. mean) 60 min after ranitidine. In patients in whom ICG clearance fell after intravenous ranitidine the hepatic extraction of ICG was also reduced. There was no significant change in the gradient between wedged and free hepatic venous pressure after ranitidine. It is therefore unlikely that ranitidine lowers liver blood flow. PMID:6137230

  11. Cold-air performance of a 12.766-centimeter-tip-diameter axial-flow cooled turbine. 3: Effect of rotor tip clearance on overall performance of a solid blade configuration

    NASA Technical Reports Server (NTRS)

    Haas, J. E.; Kofskey, M. G.

    1977-01-01

    Two tip clearance configurations, one with a recess in the casing and the other with a reduced rotor blade height, were investigated at design equivalent speed over a range of tip clearance from about 2.0 to 5.0 percent of the stator blade height. The optimum configuration with a recess in the casing was the one where the rotor tip diameter was equal to the stator tip diameter (zero blade extension). For this configuration there was an approximate 1.5 percent decrease in total efficiency for an increase in tip clearance of 1 percent of stator blade height. For the reduced blade height configurations there was an approximate 2.0 percent decrease in total efficiency for an increase in tip clearance of 1 percent of stator blade height.

  12. High Temperature Investigations into an Active Turbine Blade Tip Clearance Control Concept

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn; Steinetz, Bruce M.; Oswald, Jay J.

    2007-01-01

    System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA s Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.

  13. High Temperature Investigations into an Active Turbine Blade Tip Clearance Control Concept

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn C.; Steinetz, Bruce; Oswald, Jay J.

    2008-01-01

    System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA s Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.

  14. 2015 Annual Report on Security Clearance Determinations

    DTIC Science & Technology

    2016-06-28

    completed or pending security clearance determinations for government employees and contractors during the preceding fiscal year that have taken longer...each level during the preceding fiscal year. Similar data pertaining to USG contractors is also required. Also, for each element of the Intelligence...for USG Employees and USG Contractors Security Clearance Determination Processing Metrics for the Seven IC Agencies The number of individuals

  15. Navier-Stokes analysis of radial turbine rotor performance

    NASA Technical Reports Server (NTRS)

    Larosiliere, L. M.

    1993-01-01

    An analysis of flow through a radial turbine rotor using the three-dimensional, thin-layer Navier-Stokes code RVC3D is described. The rotor is a solid version of an air-cooled metallic radial turbine having thick trailing edges, shroud clearance, and scalloped-backface clearance. Results are presented at the nominal operating condition using both a zero-clearance model and a model simulating the effects of the shroud and scalloped-backface clearance flows. A comparison with the available test data is made and details of the internal flow physics are discussed, allowing a better understanding of the complex flow distribution within the rotor.

  16. Time-of-Flight Tip-Clearance Measurements

    NASA Technical Reports Server (NTRS)

    Dhadwal, H. S.; Kurkov, A. P.; Janetzke, D. C.

    1999-01-01

    In this paper a time-of-flight probe system incorporating the two integrated fiber optic probes which are tilted equally relative to the probe holder centerline, is applied for the first time to measure the tip clearance of an advanced fan prototype. Tip clearance is largely independent of the signal amplitude and it relies on timing measurement. This work exposes optical effects associated with the fan blade stagger angle that were absent during the original spin-rig experiment on the zero stagger rotor. Individual blade tip clearances were measured with accuracy of +/- 127-mm (+/- 0.005-in). Probe features are discussed and improvements to the design are suggested.

  17. The influences of tip clearance on the performance of nozzle blades of radial turbines - Experiment and performance prediction at three nozzle angles

    NASA Astrophysics Data System (ADS)

    Hyun, Yong-Ik; Yamaguchi, Michiteru; Hayami, Hiroshi; Senoo, Yasutoshi

    1988-05-01

    In order to study the influence of tip clearance on the turning angle and pressure loss of turbine nozzles, experimental results were obtained for nozzle angles at which the throat area was 0.8 and 1.4 times the rated condition. Contour maps of the total pressure loss and of the spanwise distributions of the mean exit-flow angle have been obtained. Although the two-layer flow model of Senoo et al., (1987) is shown to accurately predict the effects of tip clearance, it underestimates the clearance effect for a lightly loaded condition.

  18. Advanced optical blade tip clearance measurement system

    NASA Technical Reports Server (NTRS)

    Ford, M. J.; Honeycutt, R. E.; Nordlund, R. E.; Robinson, W. W.

    1978-01-01

    An advanced electro-optical system was developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in an operating gas turbine engine. This system is applicable to fan, compressor, and turbine blade tip clearance measurement requirements, and the system probe is particularly suitable for operation in the extreme turbine environment. A study of optical properties of blade tips was conducted to establish measurement system application limitations. A series of laboratory tests was conducted to determine the measurement system's operational performance characteristics and to demonstrate system capability under simulated operating gas turbine environmental conditions. Operational and environmental performance test data are presented.

  19. Emergency Department Medical Clearance of Patients with Psychiatric or Behavioral Emergencies, Part 1.

    PubMed

    Tucci, Veronica Theresa; Moukaddam, Nidal; Alam, Al; Rachal, James

    2017-09-01

    Patients presenting to the emergency department with mental illness or behavioral complaints merit workup for underlying physical conditions that can trigger, mimic, or worsen psychiatric symptoms. However, interdisciplinary consensus on medical clearance is lacking, leading to wide variations in quality of care and, quite often, poor medical care. Psychiatry and emergency medicine specialty guidelines support a tailored, customized approach. This article summarizes best-practice approaches to the medical clearance of patients with psychiatric illness, tips on history taking, system reviews, clinical or physical examination, and common pitfalls in the medical clearance process. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Toward a Fast-Response Active Turbine Tip Clearance Control

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.; Kypuros, Javier A.

    2003-01-01

    This paper describes active tip clearance control research being conducted by NASA to improve turbine engine systems. The target application for this effort is commercial aircraft engines. However, technologies developed for clearance control can benefit a broad spectrum of current and future turbomachinery. The first portion of the paper addresses the research from a programmatic viewpoint. Recent studies that provide motivation for the work, identification of key technologies, and NASA's plan for addressing deficiencies in the technologies are discussed. The later portion of the paper drills down into one of the key technologies by presenting equations and results for a preliminary dynamic model of the tip clearance phenomena.

  1. Accuracy and reproducibility of a new contrast clearance method for the determination of glomerular filtration rate.

    PubMed Central

    O'Reilly, P H; Brooman, P J; Martin, P J; Pollard, A J; Farah, N B; Mason, G C

    1986-01-01

    A new method for determining the glomerular filtration rate was analysed prospectively. The method uses an x ray fluorescence technique to measure disappearance from the plasma of injected non-ionic iodinated contrast media. Eighty seven patients were studied. Fifty four had an intravenous dose of 100 ml iohexol (Omnipaque) and 33 had 50 ml iohexol. Clearances of chromium-51 labelled edetic acid (51Cr-EDTA) were measured simultaneously. In the patients given 100 ml iohexol there was excellent correlation with 51Cr-EDTA clearance (r = 0.90). The correlation using 50 ml iohexol was also good (r = 0.85). Correlation between creatinine clearance and clearance of 51Cr-EDTA in 33 patients was less satisfactory (r = 0.69). There were no adverse reactions to the contrast media. The equipment used for measuring contrast clearance was robust and simple to operate. Freezing plasma samples in 10 studies and re-examining them weekly for six weeks showed no significant variation in results; hence reproducibility was good. This new and accurate method for determining the glomerular filtration rate merits further study and might find a useful place in routine clinical practice. Images FIG 1 PMID:3089467

  2. Turbo machine tip clearance and vibration measurements using a fibre optic laser Doppler position sensor

    NASA Astrophysics Data System (ADS)

    Pfister, T.; Büttner, L.; Czarske, J.; Krain, H.; Schodl, R.

    2006-07-01

    This paper presents a novel fibre optic laser Doppler position sensor for single blade tip clearance and vibration measurements at turbo machines, which offers high temporal resolution and high position resolution simultaneously. The sensor principle is based on the generation of a measurement volume consisting of two superposed fan-like interference fringe systems with contrary fringe spacing gradients using wavelength division multiplexing. A flexible and robust measurement system with an all-passive fibre coupled measurement head has been realized employing diffractive and refractive optics. Measurements of tip clearance and rotor vibrations at a transonic centrifugal compressor performed during operation at up to 50 000 rpm (833 Hz) corresponding to 21.7 kHz blade frequency and 586 m s-1 blade tip velocity are presented. The results are in excellent agreement with those of capacitive probes. The mean uncertainty of the position measurement was around 20 µm and, thus, considerably better than for conventional tip clearance probes. Consequently, this sensor is capable of fulfilling the requirements for future active clearance control systems and has great potential for in situ and online tip clearance and vibration measurements at metallic and non-metallic turbine blades with high precision.

  3. Supine lung clearance of Tc-99m DTPA and HMPAO aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chia-Hung Kao; Hui-Tzu Lin; Shu-Ling Yu

    1995-07-01

    The speed of Tc-99m DTPA/HMPAO radioaerosol clearance from the lungs that is represented as a slope from lungs to blood was measured in 23 male normal controls using commercial lung radioaerosol delivery units in the supine position in order to avoid the influences of gravity. The right lung was selected and three regions of interest were created for equal subdivisions of the upper, middle, and lower third. The results show that the clearance of Tc-99m DTPA/HMPAO aerosols in the upper lung is lowest. The difference between upper and lower lungs for Tc-99m DTPA/HMPAO aerosol clearances are significant. The clearance ofmore » Tc-99m DTPA aerosols was significantly faster than those of Tc-99m HMPAO in any region. The authors conclude that, although the effect of gravity disappears in the supine position in our study, the differences of aerosol clearance in different regions are still significant. Lipophilic Tc-99m HMPAO aerosols were slower than those of hydrophilic Tc-99m DTPA, which suggests there are at least two different mechanisms. 22 refs., 2 figs., 1 tab.« less

  4. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method.

    PubMed

    Jiang, Zhinong; Mao, Zhiwei; Wang, Zijia; Zhang, Jinjie

    2017-12-15

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.

  5. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry

    PubMed Central

    Black, A.; Evans, J. C.; Hadfield, Esme H.; Macbeth, R. G.; Morgan, A.; Walsh, M.

    1974-01-01

    Black, A., Evans, J. C., Hadfield, Esme H., Macbeth, R. G., Morgan, A., and Walsh, M. (1974).British Journal of Industrial Medicine,31, 10-17. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry. Measurements of mucociliary clearance from the anterior end of the middle turbinate were made using technetium-99m-labelled particles in nine woodworkers from the furniture industry and in 12 controls, none of whom had been occupationally exposed to wood dust. Clearance rates in the controls ranged from 1·9 to 18·5 mm min-1 with a mean of 6·8. These values are in good agreement with measurements reported elsewhere for normal subjects. Only one of the woodworkers had a clearance rate which fell within the normal range and he had been occupationally exposed for the shortest period (6 years). In four woodworkers clearance was very slow (< 1 mm min-1) and in three there was almost complete stasis. The results of this preliminary investigation suggest that nasal mucociliary function is significantly impaired in workers who have been exposed to wood dust in the furniture industry for more than 10 years. PMID:4821406

  6. Pharmacoepidemiologic investigation of a clonazepam-valproic acid interaction by mixed effect modeling using routine clinical pharmacokinetic data in Japanese patients.

    PubMed

    Yukawa, E; Nonaka, T; Yukawa, M; Higuchi, S; Kuroda, T; Goto, Y

    2003-12-01

    Non-linear Mixed Effects Modeling (NONMEM) was used to estimate the effects of clonazepam-valproic acid interaction on clearance values using 576 serum levels collected from 317 pediatric and adult epileptic patients (age range, 0.3-32.6 years) during their clinical routine care. Patients received the administration of clonazepam and/or valproic acid. The final model describing clonazepam clearance was CL = 144.0 TBW-0.172 1.14VPA, where CL is total body clearance (mL/kg/h); TBW is total body weight (kg); VPA = 1 for concomitant administration of valproic acid and VPA = zero otherwise. The final model describing valproic acid clearance was CL (mL/kg/h) = 17.2 TBW-0.264 DOSE0.159 0.821CZP 0.896GEN, where DOSE is the daily dose of valproic acid (mg/kg/day); CZP = 1 for concomitant administration of clonazepam and CZP = zero otherwise; GEN = 1 for female and GEN = zero otherwise. Concomitant administration of clonazepam and valproic acid resulted in a 14% increase in clonazepam clearance, and a 17.9% decrease in valproic acid clearance.

  7. The Effect of Clearance Distribution on the Performance of a Compression-ignition Engine with a Precombustion Chamber

    NASA Technical Reports Server (NTRS)

    Moore, C. S.; Collins, J. H. Jr

    1932-01-01

    The clearance distribution in a precombustion chamber cylinder head was varied so that for a constant compression ratio of 13.5 the spherical auxiliary chambers contained 20, 35, 50, and 70 per cent of the total clearance volume. Each chamber was connected to the cylinder by a single circular passage, flared at both ends, and of a cross-sectional area proportional to the chamber volume, thereby giving the same calculated air-flow velocity through each passage. Results of engine-performance tests are presented with variations of power, fuel consumption, explosion pressure, rate of pressure rise, ignition lag, heat loss to the cooling water, and motoring characteristics. For good performance the minimum auxiliary chamber volume, with the cylinder head design used, was 35 per cent of the total clearance volume; for larger volumes the performance improves but slightly. With the auxiliary chamber that contained 35 percent of the clearance volume there were obtained the lowest explosion pressures, medium rates of pressure rise, and slightly less than the maximum power. For all clearance distributions an increase in engine speed decreased the ignition lag in seconds and increased the rate of pressure rise.

  8. Update on meat irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olson, D.G.

    1997-12-01

    The irradiation of meat and poultry in the United States is intended to eliminate pathogenic bacteria from raw product, preferably after packaging to prevent recontamination. Irradiation will also increase the shelf life of raw meat and poultry products approximately two to three times the normal shelf life. Current clearances in the United States are for poultry (fresh or frozen) at doses from 1.5 to 3.0 kGy and for fresh pork at doses from 0.3 to 1.0 kGy. A petition for the clearance of all red meat was submitted to the Food and Drug Administration (FDA) in July 1994. The petitionmore » is for clearances of fresh meat at doses from 1.5 to 4.5 kGy and for frozen meat at {approximately}2.5 to 7.5 kGy. Clearance for red meat is expected before the end of 1997. There are 28 countries that have food irradiation clearances, of which 18 countries have clearances for meat or poultry. However, there are no uniform categories or approved doses for meat and poultry among the countries that could hamper international trade of irradiated meat and poultry.« less

  9. Controls Considerations for Turbine Active Clearance Control

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.

    2004-01-01

    This presentation discusses active control of turbine tip clearance from a control systems perspective. It is a subset of charts that were presented at the 2003 meeting of the International Society of Air Breathing Engines which was held August 31 through September 5 in Cleveland, Ohio. The associated reference paper is cited at the end of the presentation. The presentation describes active tip clearance control research being conducted by NASA to improve turbine engine systems. The target application for this effort is commercial aircraft engines. However, it is believed that the technologies developed as part of this research will benefit a broad spectrum of current and future turbomachinery. The first part of the presentation discusses the concept of tip clearance, problems associated with it, and the benefits of controlling it. It lays out a framework for implementing tip clearance controls that enables the implementation to progress from purely analytical to hardware-in-the-loop to fully experimental. And it briefly discusses how the technologies developed will be married to the previously described ACC Test Rig for hardware-in-the-loop demonstrations. The final portion of the presentation, describes one of the key technologies in some detail by presenting equations and results for a functional dynamic model of the tip clearance phenomena. As shown, the model exhibits many of the clearance dynamics found in commercial gas turbine engines. However, initial attempts to validate the model identified limitations that are being addressed to make the model more realistic.

  10. The measurement of skin lymph flow by isotope clearance--reliability, reproducibility, injection dynamics, and the effect of massage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mortimer, P.S.; Simmonds, R.; Rezvani, M.

    1990-12-01

    The measurement of skin lymph flow was investigated using an isotope clearance technique (ICT). Multiple lymph flow determinations were undertaken in the skin of anaesthetized large white pigs to test for reproducibility, ascertain the most suitable tracer, study the influence of injection dynamics, and observe the effect of massage as a stimulus to lymph flow. Blood clearance of tracer was also investigated. Results demonstrated that lymphatic clearance is a monoexponential function with good reproducibility under controlled laboratory conditions. 99mTc-colloid (TCK17 Cis) compared favorably with 131I-human serum albumin as a tracer and both performed better than colloid gold (198Au). Lymph flowmore » was significantly faster in one pig than in the other. No difference existed between left and right sides or between caudal and rostral sites on each flank, but clearance was significantly slower in thigh than flank skin. Sub-epidermal injections cleared faster and more consistently than either deep or subcutaneous injections. Neither injection volume nor needle tract backflow of tracer influenced results, but local massage significantly enhanced clearance. Escape of 99mTc-colloid by the blood was negligible. These results indicate that skin lymph flow can be reliably measured when conditions are controlled. Extrinsic factors such as massage strongly influence lymph flow. Greater sensitivity in detecting degrees of lymphatic insufficiency may be achieved if a standardized stimulus to lymph flow is administered during isotope clearance measurement.« less

  11. Effects of semi-floating ring bearing outer clearance on the subsynchronous oscillation of turbocharger rotor

    NASA Astrophysics Data System (ADS)

    Liang, Feng; Zhou, Ming; Xu, Quanyong

    2016-09-01

    Semi-floating ring bearing(SFRB) is developed to control the vibration of turbocharger rotor. The outer clearance of SFRB affects the magnitude and frequency of nonlinear whirl motion, which is significant for the design of turbocharger. In order to explore the effects of outer clearance, a transient finite element analysis program for rotor and oil film bearing is built and validated by a published experimental case. The nonlinear dynamic behaviors of rotor-SFRB system are simulated. According to the simulation results, two representative subsynchronous oscillations excited by the two bearings respectively are discovered. As the outer clearance of SFRB increases from 24 μm to 60 μm, the low-frequency subsynchronous oscillation experiences three steps, including a strong start, a gradual recession and a combination with the other one. At the same time, the high-frequency subsynchronous oscillation starts to appear gradually, then strengthens, and finally combines. If gravity and unbalance are neglected, the combination will start starts from high rotor speed and extents to low rotor speed, just like a "zipper". It is found from the quantitative analysis that when the outer clearance increases, the vibration amplitude experiences large value firstly, then reduction, and suddenly increasing after combination. A useful design principle of SFRB outer clearance for minimum vibration amplitude is proposed: the outer clearance value should be chosen to keep the frequency of two subsynchronous oscillations clearly separated and their amplitudes close.

  12. Impact of food on hepatic clearance of patients after endoscopic sphincterotomy.

    PubMed

    Chan, Hoi-Hung; Lai, Kwok-Hung; Lin, Chiun-Ku; Tsai, Wei-Lun; Peng, Nan-Jing; Hsu, Ping-I; Lo, Gin-Ho; Wei, Min-Ching; Wang, E-Ming; Chang, Hsueh-Wen

    2009-01-01

    The recurrence rate of common bile duct stones (CBDS) is around 3-21% after treatment by endoscopic sphincterotomy (ES). Fatty meal has been shown to improve hepatic clearance in both patients with intact gallbladder and post-cholecystectomy after ES. This study tested the effects of different kinds of food on hepatic clearance by using quantitative cholescintigraphy (QC) in patients after ES. Forty-seven patients after ES with abnormal QC were enrolled in our study. Complete ablation of sphincter function was confirmed by sphincter of Oddi manometry. Fasting QC was done in every patient shortly after normalization of liver function, and then followed with low-fat and fatty-meal QC. Each of the 47 subjects was observed for the effect on hepatic clearance at 3 different levels of treatments (diets and fasting). Additionally, possible factors responsible for recurrent CBDS were investigated by means of logistic regression. Both fatty and low-fat meals could significantly improve hepatic clearance compared with fasting in most patients after ES. But the response to food types was individualized. All patients tolerated the meals well. There was no significant relationship between the recurrence of CBDS and sex, age, intact gallbladder and presence of juxtapapillary diverticulum, CBD size, and improvement in hepatic clearance (> or = 5%) by food. Both fatty and low-fat meals improved hepatic clearance in most of the patients with CBDS after ES, but the response to meals was individualized. Therefore, there is no need to restrict the amount of fat intake for patients who have undergone ES.

  13. Estimating residual kidney function in dialysis patients without urine collection

    PubMed Central

    Shafi, Tariq; Michels, Wieneke M.; Levey, Andrew S.; Inker, Lesley A.; Dekker, Friedo W.; Krediet, Raymond T.; Hoekstra, Tiny; Schwartz, George J.; Eckfeldt, John H.; Coresh, Josef

    2016-01-01

    Residual kidney function contributes substantially to solute clearance in dialysis patients but cannot be assessed without urine collection. We used serum filtration markers to develop dialysis-specific equations to estimate urinary urea clearance without the need for urine collection. In our development cohort, we measured 24-hour urine clearances under close supervision in 44 patients and validated these equations in 826 patients from the Netherlands Cooperative Study on the Adequacy of Dialysis. For the development and validation cohorts, median urinary urea clearance was 2.6 and 2.4 mL/min, respectively. During the 24-hour visit in the development cohort, serum β-trace protein concentrations remained in steady state but concentrations of all other markers increased. In the validation cohort, bias (median measured minus estimated clearance) was low for all equations. Precision was significantly better for β-trace protein and β2-microglobulin equations and the accuracy was significantly greater for β-trace protein, β2-microglobulin and cystatin C equations, compared with the urea plus creatinine equation. Area under the receiver operator characteristic curve for detecting measured urinary urea clearance by equation-estimated urinary urea clearance (both 2 mL/min or more) were 0.821, 0.850 and 0.796 for β-trace protein, β2-microglobulin and cystatin C equations, respectively; significantly greater than the 0.663 for the urea plus creatinine equation. Thus, residual renal function can be estimated in dialysis patients without urine collections. PMID:26924062

  14. Estimating residual kidney function in dialysis patients without urine collection.

    PubMed

    Shafi, Tariq; Michels, Wieneke M; Levey, Andrew S; Inker, Lesley A; Dekker, Friedo W; Krediet, Raymond T; Hoekstra, Tiny; Schwartz, George J; Eckfeldt, John H; Coresh, Josef

    2016-05-01

    Residual kidney function contributes substantially to solute clearance in dialysis patients but cannot be assessed without urine collection. We used serum filtration markers to develop dialysis-specific equations to estimate urinary urea clearance without the need for urine collection. In our development cohort, we measured 24-hour urine clearances under close supervision in 44 patients and validated these equations in 826 patients from the Netherlands Cooperative Study on the Adequacy of Dialysis. For the development and validation cohorts, median urinary urea clearance was 2.6 and 2.4 ml/min, respectively. During the 24-hour visit in the development cohort, serum β-trace protein concentrations remained in steady state but concentrations of all other markers increased. In the validation cohort, bias (median measured minus estimated clearance) was low for all equations. Precision was significantly better for β-trace protein and β2-microglobulin equations and the accuracy was significantly greater for β-trace protein, β2-microglobulin, and cystatin C equations, compared with the urea plus creatinine equation. Area under the receiver operator characteristic curve for detecting measured urinary urea clearance by equation-estimated urinary urea clearance (both 2 ml/min or more) were 0.821, 0.850, and 0.796 for β-trace protein, β2-microglobulin, and cystatin C equations, respectively; significantly greater than the 0.663 for the urea plus creatinine equation. Thus, residual renal function can be estimated in dialysis patients without urine collections. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  15. Comparison of lung vascular and epithelial permeability indices in the adult respiratory distress syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braude, S.; Nolop, K.B.; Hughes, J.M.

    1986-06-01

    Measurements of pulmonary clearance of inhaled /sup 99m/Tc-DTPA and transvascular 113mIn-transferrin flux were made in 12 patients with established ARDS and 14 volunteer control subjects (7 smokers and 7 nonsmokers). Smokers had significantly increased /sup 99m/Tc-DTPA clearance (clearance rate constant, 3.6 +/- 0.8; mean +/- SEM) compared with nonsmokers (1.2 +/- 0.1). All patients with ARDS had increased clearance of /sup 99m/Tc-DTPA (5.2 +/- 0.9), but the finding was nonspecific in that increased clearance overlapped with the findings in normal smokers. Protein flux in smokers (protein flux units, 0.0 +/- 0.2) was similar to that in nonsmokers (0.3 +/- 0.2).more » In 9 of the 12 patients with ARDS, protein flux was increased, and as a group (3.2 +/- 1.0) they differed significantly (p less than 0.01) from the combined smoking and nonsmoking control subjects (0.2 +/- 0.1, n = 14). The parameters of DTPA clearance and transvascular protein flux correlated well in the patients with ARDS (Spearman's rank correlation = 0.71, p less than 0.01). Although /sup 99m/Tc-DTPA clearance is a sensitive technique in ARDS, a single study in this context does not allow a diagnostic conclusion because of its non-specificity. Abnormal protein flux appears to be more specific for ARDS but was not a universal finding in the patients studied.« less

  16. 19 CFR 101.4 - Entry and clearance of vessels at Customs stations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Entry and clearance of vessels at Customs stations. 101.4 Section 101.4 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY GENERAL PROVISIONS § 101.4 Entry and clearance of vessels at Customs stations. (a) Entry at Customs station. A vesse...

  17. Computers in the Cop Car: Impact of the Mobile Digital Terminal Technology on Motor Vehicle Theft Clearance and Recovery Rates in a Texas City.

    ERIC Educational Resources Information Center

    Nunn, Samuel

    1993-01-01

    Assessed the impact of the Mobile Digital Terminal technology (computers used to communicate with remote crime databases) on motor vehicle theft clearance (arresting a perpetrator) and recovery rates in Fort Worth (Texas), using a time series analysis. Impact has been ambiguous, with little evidence of improved clearance or recovery. (SLD)

  18. Effect of tip clearance on performance of small axial hydraulic turbine

    NASA Technical Reports Server (NTRS)

    Boynton, J. L.; Rohlik, H. E.

    1976-01-01

    The first two stages of a six stage liquid oxygen turbine were tested in water. One and two stage performance was determined for one shrouded and two unshrouded blade end configurations over ranges of clearance and blade-jet speed ratio. First stage, two stage, and second stage efficiencies are included as well as the effect of clearance on mass flow for two stage operation.

  19. Retrospective Evaluation of Milrinone Pharmacokinetics in Children With Kidney Injury.

    PubMed

    Gist, Katja M; Mizuno, Tomoyuki; Goldstein, Stuart L; Vinks, Alexander

    2015-12-01

    Milrinone is an inotropic agent with vasodilating properties used in the treatment of ventricular dysfunction. Milrinone is predominantly eliminated by the kidneys and accumulates in the setting of acute kidney injury (AKI). The purpose of this study was to evaluate milrinone pharmacokinetics in children with AKI with or without continuous renal replacement therapy (CRRT). Retrospective collection of milrinone therapeutic drug monitoring data in patients with AKI, including those requiring CRRT, through chart review from January 2008 to March 2014. Pharmacokinetic (PK) data were analyzed by Bayesian estimation using a pediatric population PK model (MW/Pharm). Clearance estimates were allometrically scaled to body weight. Data on 11 patients were available for analysis. Three patients required CRRT. Milrinone concentrations during continuous infusion varied 30-fold and ranged from 44 to 1343 ng/mL. Of the 33 samples obtained in 11 patients, 24 were outside the target range (72.7%), with 16 (48.5%) above and 8 (24.2%) below. Patients with AKI had significantly lower milrinone clearance (4.72 ± 2.26 L/h per 70 kg) compared with published data in patients without AKI. There was large between-patient variability in milrinone clearance (range: 2.91-13.6 L/h per 70 kg). Clearance in patients on CRRT ranged from 2.8 to 7.19 L/h per 70 kg. A significant correlation between milrinone clearance and estimated creatinine clearance was observed (r = 0.70, P = 0.0097). Allometrically scaled milrinone clearance was lower in the youngest patients (younger than 2 years), suggestive of ongoing renal maturation and existing AKI. Pediatric patients with AKI have significantly lower milrinone clearance compared with published data in patients without AKI. Large variability was noted in milrinone concentrations, and they were frequently outside the target range. The large between-patient variability in milrinone concentrations suggests that dosing regimens should be individualized in this population of critically ill patients. Evaluation of PK model-based milrinone dose optimization and the use of biomarkers as predictors of changes in clearance warrant further study.

  20. FcRn Rescues Recombinant Factor VIII Fc Fusion Protein from a VWF Independent FVIII Clearance Pathway in Mouse Hepatocytes

    PubMed Central

    van der Flier, Arjan; Liu, Zhan; Tan, Siyuan; Chen, Kai; Drager, Douglas; Liu, Tongyao; Patarroyo-White, Susannah; Jiang, Haiyan; Light, David R.

    2015-01-01

    We recently developed a longer lasting recombinant factor VIII-Fc fusion protein, rFVIIIFc, to extend the half-life of replacement FVIII for the treatment of people with hemophilia A. In order to elucidate the biological mechanism for the elongated half-life of rFVIIIFc at a cellular level we delineated the roles of VWF and the tissue-specific expression of the neonatal Fc receptor (FcRn) in the biodistribution, clearance and cycling of rFVIIIFc. We find the tissue biodistribution is similar for rFVIIIFc and rFVIII and that liver is the major clearance organ for both molecules. VWF reduces the clearance and the initial liver uptake of rFVIIIFc. Pharmacokinetic studies in FcRn chimeric mice show that FcRn expressed in somatic cells (hepatocytes or liver sinusoidal endothelial cells) mediates the decreased clearance of rFVIIIFc, but FcRn in hematopoietic cells (Kupffer cells) does not affect clearance. Immunohistochemical studies show that when rFVIII or rFVIIIFc is in dynamic equilibrium binding with VWF, they mostly co localize with VWF in Kupffer cells and macrophages, confirming a major role for liver macrophages in the internalization and clearance of the VWF-FVIII complex. In the absence of VWF a clear difference in cellular localization of VWF-free rFVIII and rFVIIIFc is observed and neither molecule is detected in Kupffer cells. Instead, rFVIII is observed in hepatocytes, indicating that free rFVIII is cleared by hepatocytes, while rFVIIIFc is observed as a diffuse liver sinusoidal staining, suggesting recycling of free-rFVIIIFc out of hepatocytes. These studies reveal two parallel linked clearance pathways, with a dominant pathway in which both rFVIIIFc and rFVIII complexed with VWF are cleared mainly by Kupffer cells without FcRn cycling. In contrast, the free fraction of rFVIII or rFVIIIFc unbound by VWF enters hepatocytes, where FcRn reduces the degradation and clearance of rFVIIIFc relative to rFVIII by cycling rFVIIIFc back to the liver sinusoid and into circulation, enabling the elongated half-life of rFVIIIFc. PMID:25905473

  1. The Handling of Immunoreactive Vasopressin by the Isolated Perfused Rat Kidney

    PubMed Central

    Rabkin, Ralph; Share, Leonard; Payne, Paul A.; Young, Judy; Crofton, Joan

    1979-01-01

    Using the isolated rat kidney perfused with an artificial medium containing glucose as the sole fuel, we studied the renal handling of immunoreactive arginine vasopressin (AVP) and determined the effect of various factors on the ability of the kidney to remove AVP. In control kidneys perfused with AVP at concentrations below 116 μU/ml, the organ clearance of AVP (OCAVP) was 1,145±47 (SE) μl/min, whereas glomerular filtration rate (GFR) averaged 515±37 μl/min. Filtration could thus account for up to 45% of the OCAVP, the balance presumably being cleared from the peritubular circulation. Of the AVP filtered, only 38% could be recovered in the urine (urinary clearance AVP averaged 205±12 μl/min) suggesting that the balance was taken up by the tubular epithelium and degraded. Fractional excretion of filtered AVP rose significantly in the presence of anoxia and cold (10°C) to 49 and 59%, respectively, but was not affected by ouabain or high levels of AVP (458±58 μU/ml). The OCAVP was not significantly altered by the absence of glucose in the perfusate, anoxia, or ureteral ligation, maneuvers that were associated with significant reductions in GFR. In these and the control experiments, there was a significant inverse correlation between GFR and peritubular clearance emphasizing the importance of the latter (r = −0.749; P < 0.001). Cold, ouabain, and high concentrations of AVP reduced the clearance of AVP by the kidneys. On the basis of these studies we conclude that the kidney clears AVP from the circulation via two pathways, glomerular clearance and peritubular clearance. This exposes both the luminal and contraluminal surfaces of the tubular cells to the hormone, allowing these cells to remove AVP from the filtrate and the peritubular compartment. Noteworthy is the observation that under several conditions when GFR falls reducing the glomerular clearance of AVP, peritubular clearance increases and the total clearance of AVP by the kidney remains constant. PMID:762248

  2. Dual roles for hepatic lectin receptors in the clearance of chilled platelets

    PubMed Central

    Rumjantseva, Viktoria; Grewal, Prabhjit K.; Wandall, Hans H.; Josefsson, Emma C.; Sørensen, Anne Louise; Larson, Göran; Marth, Jamey D.; Hartwig, John H.; Hoffmeister, Karin M.

    2015-01-01

    Chilling rapidly (<4 h) clusters Glycoprotein - (GP)Ib receptors on blood platelets, and ß2-integrins of hepatic macrophages bind ßGlcNAc residues in the clusters leading to rapid clearance of acutely chilled platelets following transfusion. Although capping the ßGlcNAc moieties by galactosylation prevents clearance, this strategy is ineffective after prolonged (>24 h) refrigeration. We report here that prolonged refrigeration increases the density/concentration of exposed galactose residues such that hepatocytes become increasingly involved in the removal of platelets using their Ashwell-Morell receptors. Macrophages always rapidly remove a large fraction of transfused platelets (~40%). With platelet cooling, hepatocyte-dependent clearance further diminishes their recoveries following transfusion. PMID:19783995

  3. A Reduced Model for Prediction of Thermal and Rotational Effects on Turbine Tip Clearance

    NASA Technical Reports Server (NTRS)

    Kypuros, Javier A.; Melcher, Kevin J.

    2003-01-01

    This paper describes a dynamic model that was developed to predict changes in turbine tip clearance the radial distance between the end of a turbine blade and the abradable tip seal. The clearance is estimated by using a first principles approach to model the thermal and mechanical effects of engine operating conditions on the turbine sub-components. These effects are summed to determine the resulting clearance. The model is demonstrated via a ground idle to maximum power transient and a lapse-rate takeoff transient. Results show the model demonstrates the expected pinch point behavior. The paper concludes by identifying knowledge gaps and suggesting additional research to improve the model.

  4. Emergency Department Medical Clearance of Patients with Psychiatric or Behavioral Emergencies, Part 2: Special Psychiatric Populations and Considerations.

    PubMed

    Alam, Al; Rachal, James; Tucci, Veronica Theresa; Moukaddam, Nidal

    2017-09-01

    Patients who present to the emergency department (ED) with mental illness or behavioral complaints merit workup for underlying physical conditions that can trigger, mimic, or worsen psychiatric symptoms. However, there are wide variations in quality of care for these individuals. Psychiatry and emergency medicine specialty guidelines support a tailored, customized approach to patients. Our group has long advocated a dynamic comanagement approach for medical clearance in the ED, and this article summarizes best-practice approaches to the medical clearance of patients with psychiatric illness, tips on history taking, system reviews, clinical/physical examination, and common pitfalls in the medical clearance process. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Investigation of Unsteady Tip Clearance Flow in a Low-Speed One and Half Stage Axial Compressor with LES And PIV

    NASA Technical Reports Server (NTRS)

    Hah, Chunill; Hathaway, Michael; Katz, Joseph; Tan, David

    2015-01-01

    The primary focus of this paper is to investigate how a rotor's unsteady tip clearance flow structure changes in a low speed one and half stage axial compressor when the rotor tip gap size is increased from 0.5 mm (0.49% of rotor tip blade chord, 2% of blade span) to 2.4 mm (2.34% chord, 4% span) at the design condition are investigated. The changes in unsteady tip clearance flow with the 0.62 % tip gap as the flow rate is reduced to near stall condition are also investigated. A Large Eddy Simulation (LES) is applied to calculate the unsteady flow field at these three flow conditions. Detailed Stereoscopic PIV (SPIV) measurements of the current flow fields were also performed at the Johns Hopkins University in a refractive index-matched test facility which renders the compressor blades and casing optically transparent. With this setup, the unsteady velocity field in the entire flow domain, including the flow inside the tip gap, can be measured. Unsteady tip clearance flow fields from LES are compared with the PIV measurements and both LES and PIV results are used to study changes in tip clearance flow structures. The current study shows that the tip clearance vortex is not a single structure as traditionally perceived. The tip clearance vortex is formed by multiple interlaced vorticities. Therefore, the tip clearance vortex is inherently unsteady. The multiple interlaced vortices never roll up to form a single structure. When phased-averaged, the tip clearance vortex appears as a single structure. When flow rate is reduced with the same tip gap, the tip clearance vortex rolls further upstream and the tip clearance vortex moves further radially inward and away from the suction side of the blade. When the tip gap size is increased at the design flow condition, the overall tip clearance vortex becomes stronger and it stays closer to the blade suction side and the vortex core extends all the way to the exit of the blade passage. Measured and calculated unsteady flow fields inside the tip gap agree fairly well. Instantaneous velocity vectors inside the tip gap from both the PIV and LES do show flow separation and reattachment at the entrance of tip gap as some earlier studies suggested. This area at the entrance of tip gap flow (the pressure side of the blade) is confined very close to the rotor tip section. With a small tip gap (0.5mm), the gap flow looks like a simple two-dimensional channel flow with larger velocity near the casing for both flow rates. A small area with a sharp velocity gradient is observed just above the rotor tip. This strong shear layer is turned radially inward when it collides with the incoming flow and forms the core structure of the tip clearance vortex. When tip gap size is increased to 2.4 mm at the design operation, the radial profile of the tip gap flow changes drastically. With the large tip gap, the gap flow looks like a two-dimensional channel flow only near the casing. Near the rotor top section, a bigger region with very large shear and reversed flow is observed.

  6. CF6 jet engine diagnostics program. High pressure turbine roundness/clearance investigation

    NASA Technical Reports Server (NTRS)

    Howard, W. D.; Fasching, W. A.

    1982-01-01

    The effects of high pressure turbine clearance changes on engine and module performance was evaluated in addition to the measurement of CF6-50C high pressure turbine Stage 1 tip clearance and stator out-of-roundness during steady-state and transient operation. The results indicated a good correlation of the analytical model of round engine clearance response with measured data. The stator out-of-roundness measurements verified that the analytical technique for predicting the distortion effects of mechanical loads is accurate, whereas the technique for calculating the effects of certain circumferential thermal gradients requires some modifications. A potential for improvement in roundness was established in the order of 0.38 mm (0.015 in.), equivalent to 0.86 percent turbine efficiency which translates to a cruise SFC improvement of 0.36 percent. The HP turbine Stage 1 tip clearance performance derivative was established as 0.44 mm (17 mils) per percent of turbine efficiency at take-off power, somewhat smaller, therefore, more sensitive than predicted from previous investigations.

  7. [Improvement in nuclear medicine diagnosis of kidney function using 99m technetium mercaptoacetyltriglycine (MAG3)].

    PubMed

    Erpenbach, K; Ebert, A; Wieler, H

    1991-03-01

    Renal scintigraphy and clearance measurement are indispensable in nephro-urologic disorders. A continuous series of 103 sequential scintigraphies and clearance measurements were performed with the new technetium-labelled agent MAG3 (Gamma-kamera, Phillips Tomo Diagnost) and 131I-orthohippuric acid (OIH) using the Oberhausen method (Nucleopan, Siemens). The time-activity curves obtained with the two radionuclides agreed exactly. Reaching a tubular excretion rate of nearly 90%, the clearance of MAG3 differed by no more than 6% from the OIH clearance in 95% of the cases. The factor between clearances of the two radionuclides was determined by means of a commercially available software according to the Oberhausen method and amounted to 0.59 +/- 0.09. The favorable physical properties and high activity of MAG3 permit exact examination of tubular function and better assessment of renal morphology than hippuran-labelled radionuclides. The low radiation dose combined with a better spatial resolution, especially, the constant availability in a nuclear medicine department should give the preference to MAG3.

  8. Non-Invasive Assessment of Liver Function

    PubMed Central

    Helmke, Steve; Colmenero, Jordi; Everson, Gregory T.

    2015-01-01

    Purpose of review It is our opinion that there is an unmet need in Hepatology for a minimally- or noninvasive test of liver function and physiology. Quantitative liver function tests (QLFTs) define the severity and prognosis of liver disease by measuring the clearance of substrates whose uptake or metabolism is dependent upon liver perfusion or hepatocyte function. Substrates with high affinity hepatic transporters exhibit high “first-pass” hepatic extraction and their clearance measures hepatic perfusion. In contrast, substrates metabolized by the liver have low first-pass extraction and their clearance measures specific drug metabolizing pathways. Recent Findings We highlight one QLFT, the dual cholate test, and introduce the concept of a disease severity index (DSI) linked to clinical outcome that quantifies the simultaneous processes of hepatocyte uptake, clearance from the systemic circulation, clearance from the portal circulation, and portal-systemic shunting. Summary It is our opinion that dual cholate is a relevant test for defining disease severity, monitoring the natural course of disease progression, and quantifying the response to therapy. PMID:25714706

  9. Potential impact of mangrove clearance on biomass and biomass size spectra of nematode along the Sudanese Red Sea coast.

    PubMed

    Sabeel, Rasha Adam Osman; Vanreusel, Ann

    2015-02-01

    The potential effect of mangrove clearance on nematode assemblage biomass, biomass size spectra (NBSS) and abundance/biomass curves (ABC) was investigated in three sites representing a varying degree of mangrove clearance as well as in three stations established at each sites representing high-, mid- and low-water levels. Results revealed significant differences in sediment and nematode characteristics between the three sites. Although both the cleared and the intact mangrove had comparable biomass values, clear differences in biomass size spectra and abundance biomass curves were observed. The results suggested that the variation in the silt fraction and the food quality positively affected the total biomass. Mangrove clearance has caused a shift from a unimodal to a bimodal biomass size spectrum at all water levels, owing to an increase in smaller-bodied opportunistic non-selective deposit feeding nematodes. The ABC further confirmed the effect of clearance by classifying the cleared mangrove as moderately to grossly disturbed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Environmental Assessment: 2005 Base Realignment and Closure Seymour Johnson Air Force Base Goldsboro, North Carolina

    DTIC Science & Technology

    2007-07-01

    clearance criteria is being prepared. Expected completion date: __ _ A temporary waiver for construction activity in the airfield vacinity was approved on...space clearance criteria is being prepared. Expected completion date: __ _ A temporary waiver for construction activity in the airfield vacinity was...construction activity in the airfield vacinity was approved on ____ (date). A permanent waiver of airfield/airspace clearance criteria was obtained on

  11. Stable isotope labeling tandem mass spectrometry (SILT) to quantify protein production and clearance rates

    PubMed Central

    Bateman, Randall J.; Munsell, Ling Y.; Chen, Xianghong; Holtzman, David M.; Yarasheski, Kevin E.

    2007-01-01

    In all biological systems, protein amount is a function of the rate of production and clearance. The speed of a response to a disturbance in protein homeostasis is determined by turnover rate. Quantifying alterations in protein synthesis and clearance rates is vital to understanding disease pathogenesis (e.g., aging, inflammation). No methods exist for quantifying production and clearance rates of low abundance (femtomole) proteins in vivo. We describe a novel, mass spectrometry-based method for quantitating low abundance protein synthesis and clearance rates in vitro and in vivo in animals and humans. The utility of this method is demonstrated with amyloid-beta (Aß), an important low abundance protein involved in Alzheimer's disease pathogenesis. We used in vivo stable isotope labeling, immunoprecipitation of Aß from cerebrospinal fluid, and quantitative liquid chromatography electrospray-ionization tandem mass spectrometry (LC-ESI-tandem MS) to quantify human Aß protein production and clearance rates. The method is sensitive and specific for stable isotope labeled amino acid incorporation into CNS (± 1% accuracy). This in vivo method can be used to identify pathophysiologic changes in protein metabolism; and may serve as a biomarker for monitoring disease risk, progression, or response to novel therapeutic agents. The technique is adaptable to other macromolecules, such as carbohydrates or lipids. PMID:17383190

  12. Limited value of the urinary phenytoin metabolic ratio for the assessment of cytochrome P4502C9 activity in vivo

    PubMed Central

    TASSANEEYAKUL, WICHITTRA; BIRKETT, DONALD J.; PASS, MICHAEL C.; MINERS, JOHN O.

    1996-01-01

    Relationships between the ratio of p-hydroxyphenytoin (p-HPPH), the major metabolite of phenytoin, to unchanged phenytoin excreted in urine (the urinary metabolic ratio or MR) were compared with a number of indices of the metabolic clearances of phenytoin and tolbutamide published previously for seventeen subjects separately administered these known cytochrome P4502C9 (CYP2C9) substrates. Significant correlations (rs=0.50–0.60, P<0.05) were observed between the phenytoin MR, derived from either 0–24 or 24–48 h urine collections, and inverse areas under the plasma unbound concentration-time curves (measured over various time intervals) of phenytoin and with plasma unbound tolbutamide clearance. Significant correlations (rs =0.59–0.74) were also observed between the phenytoin MRs and metabolic unbound clearances for p-hydroxyphenytoin formation. Despite the significant correlations, variability in tolbutamide and phenytoin metabolic clearance parameters tended to account for <50% of the variability in phenytoin MR. Correlations between the renal clearance of phenytoin and the phenytoin MRs suggest that variability in the renal clearance of unchanged drug limits the usefulness of the phenytoin MR for the investigation of factors influencing CYP2C9 activity in vivo. PMID:8971435

  13. Turbine blade tip clearance measurements using skewed dual optical beams of tip timing

    NASA Astrophysics Data System (ADS)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2011-12-01

    Optimization and active control of the clearance between turbine blades and case of the engine is identified, especially in aerospace community, as a key technology to increase engine efficiency, reduce fuel consumption and emissions and increase service life .However, the tip clearance varies during different operating conditions. Thus a reliable non-contact and online detection system is essential and ultimately used to close the tip clearance control loop. This paper described a fiber optical clearance measuring system applying skewed dual optical beams to detect the traverse time of passing blades. Two beams were specially designed with an outward angle of 18 degree and the beam spot diameters are less than 100μm within 0-4mm working range to achieve high signal-to-noise and high sensitivity. It could be theoretically analyzed that the measuring accuracy is not compromised by degradation of signal intensity caused by any number of environmental conditions such as light source instability, contamination and blade tip imperfection. Experimental tests were undertaken to achieve a high resolution of 10µm in the rotational speed range 2000-18000RPM and a measurement accuracy of 15μm, indicating that the system is capable of providing accurate and reliable data for active clearance control (ACC).

  14. Planar rigid-flexible coupling spacecraft modeling and control considering solar array deployment and joint clearance

    NASA Astrophysics Data System (ADS)

    Li, Yuanyuan; Wang, Zilu; Wang, Cong; Huang, Wenhu

    2018-01-01

    Based on Nodal Coordinate Formulation (NCF) and Absolute Nodal Coordinate Formulation (ANCF), this paper establishes rigid-flexible coupling dynamic model of the spacecraft with large deployable solar arrays and multiple clearance joints to analyze and control the satellite attitude under deployment disturbance. Considering torque spring, close cable loop (CCL) configuration and latch mechanisms, a typical spacecraft composed of a rigid main-body described by NCF and two flexible panels described by ANCF is used as a demonstration case. Nonlinear contact force model and modified Coulomb friction model are selected to establish normal contact force and tangential friction model, respectively. Generalized elastic force are derived and all generalized forces are defined in the NCF-ANCF frame. The Newmark-β method is used to solve system equations of motion. The availability and superiority of the proposed model is verified through comparing with numerical co-simulations of Patran and ADAMS software. The numerical results reveal the effects of panel flexibility, joint clearance and their coupling on satellite attitude. The effects of clearance number, clearance size and clearance stiffness on satellite attitude are investigated. Furthermore, a proportional-differential (PD) attitude controller of spacecraft is designed to discuss the effect of attitude control on the dynamic responses of the whole system.

  15. WINCLR: a Computer Code for Heat Transfer and Clearance Calculation in a Compressor

    NASA Technical Reports Server (NTRS)

    Bose, T. K.; Murthy, S. N. B.

    1994-01-01

    One of the concerns during inclement weather operation of aircraft in rain and hail storm conditions is the nature and extent of changes in compressor casing clearance. An increase in clearance affects efficiency while a decrease may cause blade rubbing with the casing. The change in clearance is the result of geometrical dimensional changes in the blades, the casing and the rotor due to heat transfer between those parts and the two-phase working fluid. The heat transfer interacts nonlinearly with the performance of the compressor, and, therefore, the determination of clearance changes necessitates a simultaneous determination of change in performance of the compressor. A computer code the WINCLR has been designed for the determination of casing clearance, that is operated interactively with the PURDU-WINCOF I code designed previously for determining the performance of a compressor. A detailed description of the WINCLR code is provided in a companion report. The current report provides details of the code with an illustrative example of application to the case of a multistage compressor. It is found in the example case that under given ingestion and operational conditions, it is possible for a compressor to undergo changes in performance in the front stages and rubbing in the back stages.

  16. Renal Function Descriptors in Neonates: Which Creatinine-Based Formula Best Describes Vancomycin Clearance?

    PubMed

    Bhongsatiern, Jiraganya; Stockmann, Chris; Yu, Tian; Constance, Jonathan E; Moorthy, Ganesh; Spigarelli, Michael G; Desai, Pankaj B; Sherwin, Catherine M T

    2016-05-01

    Growth and maturational changes have been identified as significant covariates in describing variability in clearance of renally excreted drugs such as vancomycin. Because of immaturity of clearance mechanisms, quantification of renal function in neonates is of importance. Several serum creatinine (SCr)-based renal function descriptors have been developed in adults and children, but none are selectively derived for neonates. This review summarizes development of the neonatal kidney and discusses assessment of the renal function regarding estimation of glomerular filtration rate using renal function descriptors. Furthermore, identification of the renal function descriptors that best describe the variability of vancomycin clearance was performed in a sample study of a septic neonatal cohort. Population pharmacokinetic models were developed applying a combination of age-weight, renal function descriptors, or SCr alone. In addition to age and weight, SCr or renal function descriptors significantly reduced variability of vancomycin clearance. The population pharmacokinetic models with Léger and modified Schwartz formulas were selected as the optimal final models, although the other renal function descriptors and SCr provided reasonably good fit to the data, suggesting further evaluation of the final models using external data sets and cross validation. The present study supports incorporation of renal function descriptors in the estimation of vancomycin clearance in neonates. © 2015, The American College of Clinical Pharmacology.

  17. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method

    PubMed Central

    Jiang, Zhinong; Wang, Zijia; Zhang, Jinjie

    2017-01-01

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable. PMID:29244722

  18. Augmented renal clearance is not a risk factor for mortality in Enterobacteriaceae bloodstream infections treated with appropriate empiric antimicrobials.

    PubMed

    Burnham, Jason P; Micek, Scott T; Kollef, Marin H

    2017-01-01

    The main objective of the study was to assess whether augmented renal clearance was a risk factor for mortality in a cohort of patients with Enterobacteriaceae sepsis, severe sepsis, or septic shock that all received appropriate antimicrobial therapy within 12 hours. Using a retrospective cohort from Barnes-Jewish Hospital, a 1,250-bed teaching hospital, we collected data on individuals with Enterobacteriaceae sepsis, severe sepsis, and septic shock who received appropriate initial antimicrobial therapy between June 2009 and December 2013. Clinical outcomes were compared according to renal clearance, as assessed by Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formulas, sepsis classification, demographics, severity of illness, and comorbidities. We identified 510 patients with Enterobacteriaceae bacteremia and sepsis, severe sepsis, or septic shock. Sixty-seven patients (13.1%) were nonsurvivors. Augmented renal clearance was uncommon (5.1% of patients by MDRD and 3.0% by CKD-EPI) and was not associated with increased mortality. Our results are limited by the absence of prospective determination of augmented renal clearance. However, in this small cohort, augmented renal clearance as assessed by MDRD and CKD-EPI does not seem to be a risk factor for mortality in patients with Enterobacteriaceae sepsis. Future studies should assess this finding prospectively.

  19. Effects of Tip Clearance and Casing Recess on Heat Transfer and Stage Efficiency in Axial Turbines

    NASA Technical Reports Server (NTRS)

    Ameri, A. A.; Steinthorsson, E.; Rigby, David L.

    1998-01-01

    Calculations were performed to assess the effect of the tip leakage flow on the rate of heat transfer to blade, blade tip and casing. The effect on exit angle and efficiency was also examined. Passage geometries with and without casing recess were considered. The geometry and the flow conditions of the GE-E 3 first stage turbine, which represents a modem gas turbine blade were used for the analysis. Clearance heights of 0%, 1%, 1.5% and 3% of the passage height were considered. For the two largest clearance heights considered, different recess depths were studied. There was an increase in the thermal load on all the heat transfer surfaces considered due to enlargement of the clearance gap. Introduction of recessed casing resulted in a drop in the rate of heat transfer on the pressure side but the picture on the suction side was found to be more complex for the smaller tip clearance height considered. For the larger tip clearance height the effect of casing recess was an orderly reduction in the suction side heat transfer as the casing recess height was increased. There was a marked reduction of heat load and peak values on the blade tip upon introduction of casing recess, however only a small reduction was observed on the casing itself. It was reconfirmed that there is a linear relationship between the efficiency and the tip gap height. It was also observed that the recess casing has a small effect on the efficiency but can have a moderating effect on the flow underturning at smaller tip clearances.

  20. Hawaii cohort study of serum micronutrient concentrations and clearance of incident oncogenic human papillomavirus infection of the cervix.

    PubMed

    Goodman, Marc T; Shvetsov, Yurii B; McDuffie, Katharine; Wilkens, Lynne R; Zhu, Xuemei; Franke, Adrian A; Bertram, Cathy Cramer; Kessel, Bruce; Bernice, Marge; Sunoo, Christian; Ning, Lily; Easa, David; Killeen, Jeffrey; Kamemoto, Lori; Hernandez, Brenda Y

    2007-06-15

    The degree to which the resolution of human papillomavirus (HPV) infection parallels exposure to other factors, particularly those related to nutritional status, is a relatively unexplored area of research. We established a cohort of women for long-term follow-up to examine the association of serum retinol, carotenoid, and tocopherol concentrations with the clearance of incident cervical HPV infection. Interviews and biological specimens were obtained at baseline and at 4-month intervals. At each visit, a cervical cell specimen for HPV DNA analysis and cytology and a fasting blood sample to measure micronutrient levels were collected. A Cox proportional hazards model was used to study the relationship between clearance of 189 incident (type-specific) oncogenic HPV infections and the levels of 20 serum micronutrients among 122 women. Higher circulating levels of trans-zeaxanthin, total trans-lutein/zeaxanthin, cryptoxanthin (total and beta), total trans-lycopene and cis-lycopene, carotene (alpha, beta, and total), and total carotenoids were associated with a significant decrease in the clearance time of type-specific HPV infection, particularly during the early stages of infection (120 days) was not significantly associated with circulating levels of carotenoids or tocopherols. Results from this investigation support an association of micronutrients with the rapid clearance of incident oncogenic HPV infection of the uterine cervix.

  1. R-warfarin clearances from plasma associated with polymorphic cytochrome P450 2C19 and simulated by individual physiologically based pharmacokinetic models for 11 cynomolgus monkeys.

    PubMed

    Utoh, Masahiro; Kusama, Takashi; Miura, Tomonori; Mitsui, Marina; Kawano, Mirai; Hirano, Takahiro; Shimizu, Makiko; Uno, Yasuhiro; Yamazaki, Hiroshi

    2018-02-01

    1. Cynomolgus monkey cytochrome P450 2C19 (formerly known as P450 2C75), homologous to human P450 2C19, has been identified as R-warfarin 7-hydroxylase. In this study, simulations of R-warfarin clearance in individual cynomolgus monkeys genotyped for P450 2C19 p.[(Phe100Asn; Ala103Val; Ile112Leu)] were performed using individual simplified physiologically based pharmacokinetic (PBPK) modeling. 2. Pharmacokinetic parameters and absorption rate constants, volumes of the systemic circulation, and hepatic intrinsic clearances for individual PBPK models were estimated for eleven cynomolgus monkeys. 3. One-way ANOVA revealed significant effects of the genotype (p < 0.01) on the observed elimination half-lives and areas under the curves of R-warfarin among the homozygous mutant, heterozygous mutant, and wild-type groups. R-Warfarin clearances in individual cynomolgus monkeys genotyped for P450 2C19 were simulated by simplified PBPK modeling. The modeled hepatic intrinsic clearances were significantly associated with the P450 2C19 genotypes. The liver microsomal elimination rates of R-warfarin for individual animals after in vivo administration showed significant reductions associated with the genotype (p < 0.01). 4. This study provides important information to help simulate clearances of R-warfarin and related medicines associated with polymorphic P450 2C19 in individual cynomolgus monkeys, thereby facilitating calculation of the fraction of hepatic clearance.

  2. Paracetamol pharmacokinetics and metabolism in young women.

    PubMed

    Allegaert, Karel; Peeters, Mariska Y; Beleyn, Bjorn; Smits, Anne; Kulo, Aida; van Calsteren, Kristel; Deprest, Jan; de Hoon, Jan; Knibbe, Catherijne A J

    2015-11-13

    There is relevant between individual variability in paracetamol clearance in young women. In this pooled study, we focused on the population pharmacokinetic profile of intravenous paracetamol metabolism and its covariates in young women. Population PK parameters using non-linear mixed effect modelling were estimated in a pooled dataset of plasma and urine PK studies in 69 young women [47 at delivery, 8/47 again 10-15 weeks after delivery (early postpartum), and 7/8 again 1 year after delivery (late postpartum), 22 healthy female volunteers with or without oral contraceptives]. Population PK parameters were estimated based on 815 plasma samples and 101 urine collections. Compared to healthy female volunteers (reference group) not on oral contraceptives, being at delivery was the most significant covariate for clearance to paracetamol glucuronide (Factor = 2.03), while women in early postpartum had decreased paracetamol glucuronidation clearance (Factor = 0.55). Women on contraceptives showed increased paracetamol glucuronidation clearance (Factor = 1.46). The oestradiol level did not further affect this model. Being at delivery did not prove significant for clearance to paracetamol sulphate, but was higher in pregnant women who delivered preterm (<37 weeks, Factor = 1.34) compared to term delivery and non-pregnant women. Finally, clearance of unchanged paracetamol was dependent on urine flow rate. Compared to healthy female volunteers not on oral contraceptives, urine paracetamol glucuronidation elimination in young women is affected by pregnancy (higher), early postpartum (lower) or exposure to oral contraceptives (higher), resulting in at least a two fold variability in paracetamol clearance in young women.

  3. A Single Mutation in K13 Predominates in Southern China and Is Associated With Delayed Clearance of Plasmodium falciparum Following Artemisinin Treatment.

    PubMed

    Huang, Fang; Takala-Harrison, Shannon; Jacob, Christopher G; Liu, Hui; Sun, Xiaodong; Yang, Henglin; Nyunt, Myaing M; Adams, Matthew; Zhou, Shuisen; Xia, Zhigui; Ringwald, Pascal; Bustos, Maria Dorina; Tang, Linhua; Plowe, Christopher V

    2015-11-15

    Artemisinin resistance in Plasmodium falciparum has emerged in Southeast Asia and poses a threat to malaria control and elimination. Mutations in a P. falciparum gene encoding a kelch protein on chromosome 13 have been associated with delayed parasite clearance following artemisinin treatment elsewhere in the region, but not yet in China. Therapeutic efficacy studies of artesunate and dihydroartemisinin-piperaquine were conducted from 2009 to 2012 in the Yunnan Province of China near the border with Myanmar. K13 mutations were genotyped by capillary sequencing of DNA extracted from dried blood spots collected in these clinical trials and in routine surveillance. Associations between K13 mutations and delayed parasite clearance were tested using regression models. Parasite clearance half-lives were prolonged after artemisinin treatment, with 44% of infections having half-lives >5 hours (n = 109). Fourteen mutations in K13 were observed, with an overall prevalence of 47.7% (n = 329). A single mutation, F446I, predominated, with a prevalence of 36.5%. Infections with F446I were significantly associated with parasitemia on day 3 following artemisinin treatment and with longer clearance half-lives. Plasmodium falciparum infections in southern China displayed markedly delayed clearance following artemisinin treatment. F446I was the predominant K13 mutation and was associated with delayed parasite clearance. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  4. Is there a rationale to use a dual mobility poly insert for failed Birmingham metal-on-metal hip replacements? A retrieval analysis.

    PubMed

    Renner, Lisa; Faschingbauer, Martin; Boettner, Friedrich

    2015-08-01

    Previous studies showed poor outcomes for patients undergoing revision of failed metal-on-metal total hip arthroplasty (MoM-THA) and resurfacing (RS) with an increased risk of dislocation. Dual mobility inserts are an option to retain the acetabular component and change the metal-on-metal bearing to plastic-on-metal. The current study analyzes the rationale for the off-label use of a dual mobility poly insert (MDM X3, Stryker, Mahwah, NJ) in a Birmingham metal shell (Smith & Nephew, Memphis, TN). Based on retrievals from the implant database the study compared the clearance between 20 BHR shells, 31 MDM poly inserts and 24 ADM acetabular components of different sizes. The radial clearance was calculated for each possible combination of implants [n = 81 (MDM/BHR) and n = 119 (MDM/ADM)]. An MDM mobile bearing poly insert in an ADM shell has an average clearance of 0.314 mm (SD 0.031) compared to 0.234 mm (SD 0.030) in a BHR shell (p < 0.01). The minimal clearance is 0.246 and 0.163 mm, respectively. 30.9 % of the MDM/BHR clearances were within the range of the MDM/ADM bearing and 88.9 % had a clearance of more than 0.2 mm. Clearances of the MDM poly insert in a BHR shell are reduced, and although the majority of combinations appear safe, the indication needs to be made on an individual base carefully considering alternative treatment options.

  5. Development of a Novel System to Measure a Clearance of a Passenger Platform

    NASA Astrophysics Data System (ADS)

    Shimizu, M.; Oizumi, J.; Matsuoka, R.; Takeda, H.; Okukura, H.; Ooya, A.; Koike, A.

    2016-06-01

    Clearances of a passenger platform at a railway station should be appropriately maintained for safety of both trains and passengers. In most Japanese railways clearances between a platform and a train car is measured precisely once or twice a year. Because current measurement systems operate on a track, the closure of the track is unavoidable. Since the procedure of the closure of a track is time-consuming and bothersome, we decided to develop a new system to measure clearances without the closure of a track. A new system is required to work on a platform and the required measurement accuracy is less than several millimetres. We have adopted a 3D laser scanner and stop-and-go operation for a new system. The current systems on a track measure clearances continuously at walking speed, while our system on a platform measures clearances at approximately ten metres intervals. The scanner controlled by a PC acquires a set of point data at each measuring station. Edge points of the platform, top and side points of two rails are detected from the acquired point data. Finally clearances of the platform are calculated by using the detected feature points of the platform and the rails. The results of an experiment using a prototype of our system show that the measurement accuracy by our system would be satisfactory, but our system would take more time than the current systems. Since our system requires no closure of a track, we conclude that our system would be convenient and effective.

  6. Interplay of drug metabolism and transport: a real phenomenon or an artifact of the site of measurement?

    PubMed

    Endres, Christopher J; Endres, Michael G; Unadkat, Jashvant D

    2009-01-01

    The interdependence of both transport and metabolism on the disposition of drugs has recently gained heightened attention in the literature, and has been termed the "interplay of transport and metabolism". Such "interplay" is observed when inhibition of biliary clearance of a drug results in an "apparent" increase in the metabolic clearance of the drug or vice versa. In this manuscript, we derived and explored through simulations a physiological-based pharmacokinetic model that integrates both transport and metabolism and explains the "apparent" dependence of hepatic clearance on both these processes. In addition, we show that the phenomenon of hepatic "transport-metabolism interplay" is a result of using the plasma concentration as a point of reference when calculating metabolic or biliary clearance, and this interplay is maximal when the drug is actively transported into the hepatocytes (i.e., hepatocyte sinusoidal influx clearance is greater than the sinusoidal efflux clearance). When the hepatic drug concentration is used as a reference point to calculate metabolic or biliary clearance, this interplay ceases to exist. A mechanistic understanding of this interplay phenomenon can be used to explain the somewhat paradoxical results that may be observed in drug-drug interaction studies when a drug is cleared by both metabolism and biliary excretion. That is, when one of these two pathways is inhibited, the other pathway appears to be induced or activated. This interplay results in an increase in hepatic drug concentrations and therefore has implications for the hepatic efficacy and toxicity of a drug.

  7. Population pharmacokinetic and pharmacogenetic analysis of tacrolimus in paediatric liver transplant patients

    PubMed Central

    Abdel Jalil, Mariam H; Hawwa, Ahmed F; McKiernan, Patrick J; Shields, Michael D; McElnay, James C

    2014-01-01

    Aims To build a population pharmacokinetic model that describes the apparent clearance of tacrolimus and the potential demographic, clinical and genetically controlled factors that could lead to inter-patient pharmacokinetic variability within children following liver transplantation. Methods The present study retrospectively examined tacrolimus whole blood pre-dose concentrations (n = 628) of 43 children during their first year post-liver transplantation. Population pharmacokinetic analysis was performed using the non-linear mixed effects modelling program (nonmem) to determine the population mean parameter estimate of clearance and influential covariates. Results The final model identified time post-transplantation and CYP3A5*1 allele as influential covariates on tacrolimus apparent clearance according to the following equation: where TVCL is the typical value for apparent clearance, TPT is time post-transplantation in days and the CYP3A5 is 1 where *1 allele is present and 0 otherwise. The population estimate and inter-individual variability (%CV) of tacrolimus apparent clearance were found to be 0.977 l h−1 kg−1 (95% CI 0.958, 0.996) and 40.0%, respectively, while the residual variability between the observed and predicted concentrations was 35.4%. Conclusion Tacrolimus apparent clearance was influenced by time post-transplantation and CYP3A5 genotypes. The results of this study, once confirmed by a large scale prospective study, can be used in conjunction with therapeutic drug monitoring to recommend tacrolimus dose adjustments that take into account not only body weight but also genetic and time-related changes in tacrolimus clearance. PMID:23738951

  8. Clearance of the cervical spine in clinically unevaluable trauma patients.

    PubMed

    Halpern, Casey H; Milby, Andrew H; Guo, Wensheng; Schuster, James M; Gracias, Vicente H; Stein, Sherman C

    2010-08-15

    Meta-analytic costeffectiveness analysis. Our goal was to compare the results of different management strategies for trauma patients in whom the cervical spine was not clinically evaluable due to impaired consciousness, endotracheal intubation, or painful distracting injuries. We performed a structured literature review related to cervical spine trauma, radiographic clearance techniques (plain radiography, flexion/extension, CT, and MRI), and complications associated with semirigid collar use. Meta-analytic techniques were used to pool data from multiple sources to calculate pooled mean estimates of sensitivities and specificities of imaging techniques for cervical spinal clearance, rates of complications from various clearance strategies and from empirical use of semirigid collars. A decision analysis model was used to compare outcomes and costs among these strategies. Slightly more than 7.5% of patients who are clinically unevaluable have cervical spine injuries, and 42% of these injuries are associated with spinal instability. Sensitivity of plain radiography or fluoroscopy for spinal clearance was 57% (95% CI: 57%-60%). Sensitivities for CT and MRI alone were 83% (82%-84%) and 87% (84%-89%), respectively. Complications associated with collar use ranged from 1.3% (2 days) to 7.1% (10 days) but were usually minor and short-lived. Quadriplegia resulting from spinal instability missed by a clearance test had enormous impacts on longevity, quality of life, and costs. These impacts overshadowed the effects of prolonged collar application, even when the incidence of quadriplegia was extremely low. As currently used, neuroimaging studies for cervical spinal clearance in clinically unevaluable patients are not cost-effective compared with empirical immobilization in a semirigid collar.

  9. Impaired bolus clearance in combined high-resolution esophageal manometry and impedance measurement helps to differentiate between esophagogastric junction outflow obstruction and achalasia.

    PubMed

    Zizer, Eugen; Seufferlein, Thomas; Hänle, Mark Martin

    2017-02-01

    Introduction and aims  High-resolution esophageal manometry (HRM) has improved the diagnostic work-up of esophageal motility disorders. Simultaneous evaluation of bolus clearance delivers useful information about the function of tubular esophagus. We assessed bolus clearance in a combined HRM-impedance examination for esophagogastric junction outflow obstruction (EGJOO) in comparison to achalasia patients. The collected data were assessed in a retrospective analysis. Patients and methods  After gastroscopy excluded a mechanical esophageal or gastric obstruction, 142 consecutive patients underwent combined HRM-impedance examination. The assessment and interpretation of the manometry results were done according to the Chicago Classification of esophageal motility disorders v3.0. After classifying the motility disorder, the evaluation of bolus clearance was done according to published studies. Results  All patients with achalasia (n = 24) showed a significantly impaired bolus clearance (< 80 %). Patients with unaffected peristalsis (n = 56) or patients with EGJOO (n = 14) each showed impaired clearance in 7 %, respectively. The evidence of axial hernia was not associated with impaired clearance. Conclusion  Our results demonstrate a significant difference in impedance measurements between EGJOO and achalasia cases. This might be helpful as an additional tool to differentiate between achalasia and EGJOO patients. Furthermore, the role of the combined impedance-HRM investigation for early diagnosis of achalasia in "pre-achalasia" condition or in evaluation of potential progress of EGJOO to achalasia should be evaluated in a prospective study. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Prognostic significance of blood lactate and lactate clearance in trauma patients.

    PubMed

    Régnier, Marie-Alix; Raux, Mathieu; Le Manach, Yannick; Asencio, Yves; Gaillard, Johann; Devilliers, Catherine; Langeron, Olivier; Riou, Bruno

    2012-12-01

    Lactate has been shown to be a prognostic biomarker in trauma. Although lactate clearance has already been proposed as an intermediate endpoint in randomized trials, its precise role in trauma patients remains to be determined. Blood lactate levels and lactate clearance (LC) were calculated at admission and 2 and 4 h later in trauma patients. The association of initial blood lactate level and lactate clearance with mortality was tested using receiver-operating characteristics curve, logistic regression using triage scores, Trauma Related Injury Severity Score as a reference standard, and reclassification method. The authors evaluated 586 trauma patients (mean age 38±16 yr, 84% blunt and 16% penetrating, mortality 13%). Blood lactate levels at admission were elevated in 327 (56%) patients. The lactate clearance should be calculated within the first 2 h after admission as LC0-2 h was correlated with LC0-4 h (R=0.55, P<0.001) but not with LC2-4 h (R=0.04, not significant). The lactate clearance provides additional predictive information to initial blood lactate levels and triage scores and the reference score. This additional information may be summarized using a categorical approach (i.e., less than or equal to -20 %/h) in contrast to initial blood lactate. The results were comparable in patients with high (5 mM/l or more) initial blood lactate. Early (0-2 h) lactate clearance is an important and independent prognostic variable that should probably be incorporated in future decision schemes for the resuscitation of trauma patients.

  11. Effects of shoe sole geometry on toe clearance and walking stability in older adults.

    PubMed

    Thies, S B; Price, C; Kenney, L P J; Baker, R

    2015-07-01

    Thirty-five percent of people above age 65 fall each year, and half of their falls are associated with tripping: tripping, an apparently 'mundane' everyday problem, therefore, significantly impacts on older people's health and associated medical costs. To avoid tripping and subsequent falling, sufficient toe clearance during the swing phase is crucial. We previously found that a rocker-shaped shoe sole enhances toe clearance in young adults, thereby decreasing their trip-risk. This study investigates whether such sole design also enhances older adults' toe clearance, without inadvertently affecting their walking stability. Toe clearance and its variability are reported together with measures of walking stability for twelve older adults, walking in shoes with rocker angles of 10°, 15°, and 20°. Surface inclinations (flat, incline, decline) were chosen to reflect a potential real-world environment. Toe clearance increased substantially from the 10° to the 15° rocker angle (p=0.003) without compromising measures of walking stability (p>0.05). A further increase in rocker angle to 20° resulted in less substantial enhancement of toe clearance and came at the cost of a decrease in gait speed on the decline. The novelty of this investigation lies in the exploration of the trade-off between reduction of trip-risk through footwear design and adverse effects on walking stability on real-life relevant surfaces. Our two studies suggest that the current focus on slip-resistance in footwear design may need to be generalised to include other factors that affect trip-risk. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Histaminergic regulation of natural killer cell-mediated clearance of tumour cells in mice.

    PubMed

    Asea, A; Hermodsson, S; Hellstrand, K

    1996-01-01

    Treatment of Swiss albino mice with histamine enhanced the clearance of natural killer (NK)-cell sensitive YAC-1 lymphoma and B16/F10 melanoma cells from lung tissue in vivo, but did not affect the elimination of NK-cell-insensitive P815 mastocytoma cells. The effect of histamine was apparently mediated by H2-type histamine receptors (H2R) since it was blocked by ranitidine, and H2R antagonist. Histamine did not affect clearance of tumour cells in animals depleted of NK cells in vivo by treatment with antibodies to asialo-GM1 or NK1.1. The effect of histamine was time-dependent: pretreatment with histamine for 3 h significantly augmented the clearance of YAC-1 cells, whereas, pretreatment with histamine for 5 min was ineffective. Histamine potentiated the anti-tumour properties of NK-cell activators such as interleukin-2 (IL-2) or interferon-alpha (IFN-alpha) in vivo. None of these lymphokines significantly affected the clearance of YAC-1 cells unless animals were concomitantly treated with histamine. Treatment with ranitidine alone reduced the in vivo clearance of YAC-1 cells from lungs but did not affect the clearance of NK-cell-insensitive P815 cells. Effects of ranitidine on NK-cell function in vivo were not shared by a chemical control to ranitidine, AH20239AA, thus indicating that the inhibition of NK-cells results from H2R antagonism rather than non-specific toxicity. It is concluded that histaminergic mechanisms may be involved in the regulation of NK cell function in vivo.

  13. Influence of road network and population demand assumptions in evacuation modeling for distant tsunamis

    USGS Publications Warehouse

    Henry, Kevin; Wood, Nathan J.; Frazier, Tim G.

    2017-01-01

    Tsunami evacuation planning in coastal communities is typically focused on local events where at-risk individuals must move on foot in a matter of minutes to safety. Less attention has been placed on distant tsunamis, where evacuations unfold over several hours, are often dominated by vehicle use and are managed by public safety officials. Traditional traffic simulation models focus on estimating clearance times but often overlook the influence of varying population demand, alternative modes, background traffic, shadow evacuation, and traffic management alternatives. These factors are especially important for island communities with limited egress options to safety. We use the coastal community of Balboa Island, California (USA), as a case study to explore the range of potential clearance times prior to wave arrival for a distant tsunami scenario. We use a first-in–first-out queuing simulation environment to estimate variations in clearance times, given varying assumptions of the evacuating population (demand) and the road network over which they evacuate (supply). Results suggest clearance times are less than wave arrival times for a distant tsunami, except when we assume maximum vehicle usage for residents, employees, and tourists for a weekend scenario. A two-lane bridge to the mainland was the primary traffic bottleneck, thereby minimizing the effect of departure times, shadow evacuations, background traffic, boat-based evacuations, and traffic light timing on overall community clearance time. Reducing vehicular demand generally reduced clearance time, whereas improvements to road capacity had mixed results. Finally, failure to recognize non-residential employee and tourist populations in the vehicle demand substantially underestimated clearance time.

  14. Mechanisms of failed apoptotic cell clearance by phagocyte subsets in cardiovascular disease

    PubMed Central

    2013-01-01

    Recent evidence in humans indicate that defective phagocytic clearance of dying cells is linked to progression of advanced atherosclerotic lesions, the precursor to atherothrombosis, ischemic heart disease, and leading cause of death in the industrialized world. During atherogenesis, apoptotic cell turnover in the vascular wall is counterbalanced by neighboring phagocytes with high clearance efficiency, thereby limiting cellularity and maintaining lesion integrity. However, as lesions mature, phagocytic removal of apoptotic cells (efferocytosis) becomes defective, leading to secondary necrosis, expansion of plaque necrotic cores, and susceptibility to rupture. Recent genetic causation studies in experimental rodents have implicated key molecular regulators of efferocytosis in atherosclerotic progression. These include MER tyrosine kinase (MERTK), milk fat globule-EGF factor 8 (MFGE8), and complement C1q. At the cellular level, atheromata are infiltrated by a heterogenous population of professional phagocytes, comprised of monocytes, differentiated macrophages, and CD11c+ dendritic-like cells. Each cell type is characterized by disparate clearance efficiencies and varying activities of key phagocytic signaling molecules. It is in this context that we outline a working model whereby plaque necrosis and destabilization is jointly promoted by (1) direct inhibition of core phagocytic signaling pathways and (2) expansion of phagocyte subsets with poor clearance capacity. Towards identifying targets for promoting efficient apoptotic cell clearance and resolving inflammation in atherosclerosis and during ischemic heart disease and post myocardial infarction, this review will discuss potential in vivo suppressors of efferocytosis at each stage of clearance and how these putative interventional targets may differentially affect uptake at the level of vascular phagocyte subsets. PMID:20552278

  15. A polymorphism near IL28B is associated with spontaneous clearance of acute hepatitis C virus and jaundice.

    PubMed

    Tillmann, Hans L; Thompson, Alex J; Patel, Keyur; Wiese, Manfred; Tenckhoff, Hannelore; Nischalke, Hans D; Lokhnygina, Yuliya; Kullig, Ulrike; Göbel, Uwe; Capka, Emanuela; Wiegand, Johannes; Schiefke, Ingolf; Güthoff, Wolfgang; Grüngreiff, Kurt; König, Ingrid; Spengler, Ulrich; McCarthy, Jeanette; Shianna, Kevin V; Goldstein, David B; McHutchison, John G; Timm, Jörg; Nattermann, Jacob

    2010-11-01

    A single nucleotide polymorphism (SNP) upstream of the IL28B gene has been associated with response of patients with chronic hepatitis C to therapy with pegylated interferon and ribavirin and also with spontaneous clearance of acute hepatitis C in a heterogeneous population. We analyzed the association between IL28B and the clinical presentation of acute hepatitis C virus (HCV) infection in a homogeneous population. We analyzed the SNP rs12979860 in 190 women from the German anti-D cohort (infected with HCV genotype 1b via contaminated rhesus prophylaxis) and its association with spontaneous clearance. Clinical data were available in 136 women with acute infection who were also evaluated for IL28B genotype. Based on results of a TaqMan polymerase chain reaction assay, the rs12979860 SNP genotypes studied were C/C, C/T, or T/T. Spontaneous clearance was more common in patients with the C/C genotype (43/67; 64%) compared with C/T (22/90; 24%) or T/T (2/33; 6%) (P < .001). Jaundice during acute infection was more common among patients with C/C genotype (32.7%) than non-C/C patients (with C/T or T/T) (16.1%; P = .032). In C/C patients, jaundice during acute infection was not associated with an increased chance of spontaneous clearance (56.3%) compared with those without jaundice (60.6%). In contrast, in non-C/C patients, jaundice was associated with a higher likelihood of spontaneous clearance (42.9%) compared with those without jaundice (13.7%). The SNP rs12979860 upstream of IL28B is associated with spontaneous clearance of HCV. Women with the C/T or T/T genotype who did not develop jaundice had a lower chance of spontaneous clearance of HCV infection. Copyright © 2010 AGA Institute. Published by Elsevier Inc. All rights reserved.

  16. Population pharmacokinetics and pharmacodynamics of enoxaparin in unstable angina and non-ST-segment elevation myocardial infarction

    PubMed Central

    Bruno, René; Baille, Pascale; Retout, Sylvie; Vivier, Nicole; Veyrat-Follet, Christine; Sanderink, Ger-Jan; Becker, Richard; Antman, Elliott M

    2003-01-01

    Aims A major concern with any antithrombotic therapy is an increase in the risk of haemorrhage. The aim of this study was to analyse population pharmacokinetics and pharmacokinetic/pharmacodynamic (PK/PD) relationships for enoxaparin in patients with unstable angina (UA) and non-ST-segment elevation myocardial infarction (NSTEMI), which may help predict risk of haemorrhage. Methods Anti-factor Xa (anti-Xa) activity was measured as marker of enoxaparin concentration in 448 patients receiving the drug as a single 30-mg intravenous bolus followed by 1.0 or 1.25 mg kg−1 subcutaneously twice a day. A population pharmacokinetic analysis was conducted and individual estimates of enoxaparin clearance and area under the curve were tested as prognostic factors for the occurrence of haemorrhagic episodes. Results Basic population PK parameters were an enoxaparin clearance of 0.733 l h−1[95% confidence interval (CI) 0.698, 0.738], a distribution volume of 5.24 l (95% CI 4.20, 6.28) and an elimination half-life of 5.0 h. Enoxaparin clearance was significantly related to patient weight and creatinine clearance, and was the only independent predictor of experiencing both all (10.7%, P = 0.0013) and major (2.2%, P = 0.0004) haemorrhagic events. A creatinine clearance of 30 ml min−1 was associated with a decrease in enoxaparin clearance of 27% compared with that in a patient with a median creatinine clearance of 88 ml min−1, and was related to a 1.5- and 3.8-fold increase in the risk of ‘all’ and ‘major’ haemorrhagic episodes, respectively. Conclusions Enoxaparin clearance depends on body weight, and, therefore, weight-adjusted dosing is recommended to minimize interpatient variability in drug exposure and the risk of haemorrhage. The importance of an increased risk of haemorrhage with decreasing renal function must be weighed against the benefit of treatment with enoxaparin in patients with UA and NSTEMI. PMID:12968985

  17. Effects of nitrogen dioxide on respiratory tract clearance in the ferret

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rasmussen, R.E.; Mannix, R.C.; Oldham, M.J.

    1994-01-01

    During growth and development, young children are periodically exposed to relatively high concentrations of various air contaminants, including tobacco smoke and environmental pollutants generated by fossil fuel use. The effects of these exposures on respiratory function and lung development are difficult to determine because of interindividual variation and lack of accurate dosimetry. To provide information on the effects of chronic exposure to a common indoor and outdoor pollutant during lung development, a study was performed to assess the effects of exposure to two concentrations of nitrogen dioxide (NO[sub 2]; 0.5 or 10 ppm) on tracer particle clearance from the airwaysmore » of ferrets exposed during postnatal respiratory tract development. Separate groups of ferrets were exposed nose-only to the test atmospheres or clean air 4 h/d, 5 d/wk, for either 8 or 15 wk. Those animals exposed for 8 wk were subsequently housed in a filtered air environment until the particle clearance measurements commenced at 3 wk prior to the end of the 15-wk exposure protocol. Radiolabeled ([sup 51]Cr) tracer particles were deposited in the respiratory tract of all animals by inhalation, and the clearance rates from the head and thoracic regions were separately monitored for 18 d. No significant effects of the NO[sub 2] exposure on head airways clearance were seen. In contrast, the rates of particle clearance from the thorax of both the 8- and 15-wk groups exposed to 10 ppm NO[sub 2] were significantly reduced, and did not differ from each other. Thoracic clearance was also reduced in animals exposed to 0.5 ppm, but the rate was not significantly different from that of the clean air exposed controls. These results show that NO[sub 2] at moderate concentrations caused highly significant changes in the deep lung of the juvenile ferret, and suggest that impairment of the clearance function may be only slowly recovered after chronic exposure. 35 refs., 1 fig., 1 tab.« less

  18. Cervical Spine Clearance in Pediatric Trauma Centers: The Need for Standardization and an Evidence-based Protocol.

    PubMed

    Pannu, Gurpal S; Shah, Mitesh P; Herman, Marty J

    Cervical spine clearance in the pediatric trauma patient represents a particularly challenging task. Unfortunately, standardized clearance protocols for pediatric cervical clearance are poorly reported in the literature and imaging recommendations demonstrate considerable variability. With the use of a web-based survey, this study aims to define the methods utilized by pediatric trauma centers throughout North America. Specific attention was given to the identification of personnel responsible for cervical spine care, diagnostic imaging modalities used, and the presence or absence of a written pediatric cervical spine clearance protocol. A 10-question electronic survey was given to members of the newly formed Pediatric Cervical Spine Study Group, all of whom are active POSNA members. The survey was submitted via the online service SurveyMonkey (https://www.surveymonkey.com/r/7NVVQZR). The survey assessed the respondent's institution demographics, such as trauma level and services primarily responsible for consultation and operative management of cervical spine injuries. In addition, respondents were asked to identify the protocols and primary imaging modality used for cervical spine clearance. Finally, respondents were asked if their institution had a documented cervical spine clearance protocol. Of the 25 separate institutions evaluated, 21 were designated as level 1 trauma centers. Considerable variation was reported with regards to the primary service responsible for cervical spine clearance. General Surgery/Trauma (44%) is most commonly the primary service, followed by a rotating schedule (33%), Neurosugery (11%), and Orthopaedic Surgery (8%). Spine consults tend to be seen most commonly by a rotating schedule of Orthopaedic Surgery and Neurosurgery. The majority of responding institutions utilize computed tomographic imaging (46%) as the primary imaging modality, whereas 42% of hospitals used x-ray primarily. The remaining institutions reported using a combination of x-ray and computed tomographic imaging. Only 46% of institutions utilize a written, standardized pediatric cervical spine clearance protocol. This study demonstrates a striking variability in the use of personnel, imaging modalities and, most importantly, standardized protocol in the evaluation of the pediatric trauma patient with a potential cervical spine injury. Cervical spine clearance protocols have been shown to decrease the incidence of missed injuries, minimize excessive radiation exposure, decrease the time to collar removal, and lower overall associated costs. It is our opinion that development of a task force or multicenter research protocol that incorporates existing evidence-based literature is the next best step in improving the care of children with cervical spine injuries. Level 4-economic and decision analyses.

  19. Longitudinal Associations among Renal Urea Clearance-Corrected Normalized Protein Catabolic Rate, Serum Albumin, and Mortality in Patients on Hemodialysis.

    PubMed

    Eriguchi, Rieko; Obi, Yoshitsugu; Streja, Elani; Tortorici, Amanda R; Rhee, Connie M; Soohoo, Melissa; Kim, Taehee; Kovesdy, Csaba P; Kalantar-Zadeh, Kamyar

    2017-07-07

    There are inconsistent reports on the association of dietary protein intake with serum albumin and outcomes among patients on hemodialysis. Using a new normalized protein catabolic rate (nPCR) variable accounting for residual renal urea clearance, we hypothesized that higher baseline nPCR and rise in nPCR would be associated with higher serum albumin and better survival among incident hemodialysis patients. Among 36,757 incident hemodialysis patients in a large United States dialysis organization, we examined baseline and change in renal urea clearance-corrected nPCR as a protein intake surrogate and modeled their associations with serum albumin and mortality over 5 years (1/2007-12/2011). Median nPCRs with and without accounting for renal urea clearance at baseline were 0.94 and 0.78 g/kg per day, respectively (median within-patient difference, 0.14 [interquartile range, 0.07-0.23] g/kg per day). During a median follow-up period of 1.4 years, 8481 deaths were observed. Baseline renal urea clearance-corrected nPCR was associated with higher serum albumin and lower mortality in the fully adjusted model ( P trend <0.001). Among 13,895 patients with available data, greater rise in renal urea clearance-corrected nPCR during the first 6 months was also associated with attaining high serum albumin (≥3.8 g/dl) and lower mortality ( P trend <0.001); compared with the reference group (a change of 0.1-0.2 g/kg per day), odds and hazard ratios were 0.53 (95% confidence interval, 0.44 to 0.63) and 1.32 (95% confidence interval, 1.14 to 1.54), respectively, among patients with a change of <-0.2 g/kg per day and 1.62 (95% confidence interval, 1.35 to 1.96) and 0.76 (95% confidence interval, 0.64 to 0.90), respectively, among those with a change of ≥0.5 g/kg per day. Within a given category of nPCR without accounting for renal urea clearance, higher levels of renal urea clearance-corrected nPCR consistently showed lower mortality risk. Among incident hemodialysis patients, higher dietary protein intake represented by nPCR and its changes over time appear to be associated with increased serum albumin levels and greater survival. nPCR may be underestimated when not accounting for renal urea clearance. Compared with the conventional nPCR, renal urea clearance-corrected nPCR may be a better marker of mortality. Copyright © 2017 by the American Society of Nephrology.

  20. Dual clearance squeeze film damper

    NASA Technical Reports Server (NTRS)

    Fleming, D. P. (Inventor)

    1985-01-01

    A dual clearance hydrodynamic liquid squeeze film damper for a gas turbine engine is described. Under normal operating conditions, the device functions as a conventional squeeze film damper, using only one of its oil films. When an unbalance reaches abusive levels, as may occur with a blade loss or foreign object damage, a second, larger clearance film becomes active, controlling vibration amplitudes in a near optimum manner until the engine can be safely shut down and repaired.

  1. Initial, Cockpit Anthropometric Assessment of U.S. Navy T-6 Life Support Equipment

    DTIC Science & Technology

    2007-11-05

    DEP was not specified. Zone 1, 2, and 3 reach conditions to controls and pedals and clearances were in accordance with military standard...functional leg reach as operation of pedals ; cockpit volume clearances, including ejection clearances not striking objects unintention-ally; and overhead...was measured from knee to any obstruction. Reach to pedals was measured from a position where full control was achieved. Arm reach was measured for

  2. Nuclear core positioning system

    DOEpatents

    Garkisch, Hans D.; Yant, Howard W.; Patterson, John F.

    1979-01-01

    A structural support system for the core of a nuclear reactor which achieves relatively restricted clearances at operating conditions and yet allows sufficient clearance between fuel assemblies at refueling temperatures. Axially displaced spacer pads having variable between pad spacing and a temperature compensated radial restraint system are utilized to maintain clearances between the fuel elements. The core support plates are constructed of metals specially chosen such that differential thermal expansion produces positive restraint at operating temperatures.

  3. Receptor for advanced glycation end products binds to phosphatidylserine and assists in the clearance of apoptotic cells

    PubMed Central

    He, Mei; Kubo, Hiroshi; Morimoto, Konosuke; Fujino, Naoya; Suzuki, Takaya; Takahasi, Toru; Yamada, Mitsuhiro; Yamaya, Mutsuo; Maekawa, Tomoyuki; Yamamoto, Yasuhiko; Yamamoto, Hiroshi

    2011-01-01

    Clearance of apoptotic cells is necessary for tissue development, homeostasis and resolution of inflammation. The uptake of apoptotic cells is initiated by an ‘eat-me' signal, such as phosphatidylserine, on the cell surface and phagocytes recognize the signal by using specific receptors. In this study, we show that the soluble form of the receptor for advanced glycation end products (RAGE) binds to phosphatidylserine as well as to the apoptotic thymocytes. RAGE-deficient (Rage−/−) alveolar macrophages showed impaired phagocytosis of apoptotic thymocytes and defective clearance of apoptotic neutrophils in Rage−/− mice. Our results indicate that RAGE functions as a phosphatidylserine receptor and assists in the clearance of apoptotic cells. PMID:21399623

  4. Exosomes as Carriers of Alzheimer's Amyloid-ß

    PubMed Central

    Yuyama, Kohei; Igarashi, Yasuyuki

    2017-01-01

    The intracerebral level of the aggregation-prone peptide, amyloid-ß (Aß), is constantly maintained by multiple clearance mechanisms, including several degradation enzymes, and brain efflux. Disruption of the clearance machinery and the resultant Aß accumulation gives rise to neurotoxic assemblies, leading to the pathogenesis of Alzheimer's disease (AD). In addition to the classic mechanisms of Aß clearance, the protein may be processed by secreted vesicles, although this possibility has not been extensively investigated. We showed that neuronal exosomes, a subtype of extracellular nanovesicles, enwrap, or trap Aß and transport it into microglia for degradation. Here, we review Aß sequestration and elimination by exosomes, and discuss how this clearance machinery might contribute to AD pathogenesis and how it might be exploited for effective AD therapy. PMID:28487629

  5. DOE DISS/ET pilot system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strait, R.S.; Wagner, E.E.

    1994-07-01

    The US Department of Energy (DOE) Office of Safeguards and Security initiated the DOE Integrated Security System / Electronic Transfer (DISS/ET) for the purpose of reducing the time required to process security clearance requests. DISS/ET will be an integrated system using electronic commerce technologies for the collection and processing of personnel security clearance data, and its transfer between DOE local security clearance offices, DOE Operations Offices, and the Office of Personnel Management. The system will use electronic forms to collect clearance applicant data. The forms data will be combined with electronic fingerprint images and packaged in a secure encrypted electronicmore » mail envelope for transmission across the Internet. Information provided by the applicant will be authenticated using digital signatures. All processing will be done electronically.« less

  6. Experimental study on the sealing clearance between the labyrinth sealing displacer and cylinder in the 10 K G-M refrigerator

    NASA Astrophysics Data System (ADS)

    Hao, X. H.; Ju, Y. L.; Lu, Y. J.

    2011-05-01

    The labyrinth sealing displacer has been optimal designed to improve the operating stability and life-time of 10 K G-M refrigerator. The displacer was made of stainless steel 304 or inconel 718, coated with PTFE on its outer surface. Compared to the traditional piston-ring sealing displacer, the sealing clearance between the ridge of the labyrinth sealing displacer and cylinder is critical to the cooling performance of the G-M refrigerator. The displacers with different sealing clearances were experimentally studied, and the optimal clearance was given. The effects of the materials of the displacers and the system charge pressures on the performance of the labyrinth sealing were also tested and analyzed.

  7. Clearing the Dead: Apoptotic Cell Sensing, Recognition, Engulfment, and Digestion

    PubMed Central

    Hochreiter-Hufford, Amelia; Ravichandran, Kodi S.

    2013-01-01

    Clearance of apoptotic cells is the final stage of programmed cell death. Uncleared corpses can become secondarily necrotic, promoting inflammation and autoimmunity. Remarkably, even in tissues with high cellular turnover, apoptotic cells are rarely seen because of efficient clearance mechanisms in healthy individuals. Recently, significant progress has been made in understanding the steps involved in prompt cell clearance in vivo. These include the sensing of corpses via “find me” signals, the recognition of corpses via “eat me” signals and their cognate receptors, the signaling pathways that regulate cytoskeletal rearrangement necessary for engulfment, and the responses of the phagocyte that keep cell clearance events “immunologically silent.” This study focuses on our understanding of these steps. PMID:23284042

  8. 77 FR 7567 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... authoritative source for clearance information resulting in accesses determinations to sensitive/classified... Personnel Security System and is the authoritative source for clearance information resulting in accesses...

  9. Creatinine generation from kinetic modeling with or without postdialysis serum creatinine measurement: results from the HEMO study.

    PubMed

    Daugirdas, John T; Depner, Thomas A

    2017-11-01

    A convenient method to estimate the creatinine generation rate and measures of creatinine clearance in hemodialysis patients using formal kinetic modeling and standard pre- and postdialysis blood samples has not been described. We used data from 366 dialysis sessions characterized during follow-up month 4 of the HEMO study, during which cross-dialyzer clearances for both urea and creatinine were available. Blood samples taken at 1 h into dialysis and 30 min and 60 min after dialysis were used to determine how well a two-pool kinetic model could predict creatinine concentrations and other kinetic parameters, including the creatinine generation rate. An extrarenal creatinine clearance of 0.038 l/kg/24 h was included in the model. Diffusive cross-dialyzer clearances of urea [230 (SD 37 mL/min] correlated well (R2 = 0.78) with creatinine clearances [164 (SD 30) mL/min]. When the effective diffusion volume flow rate was set at 0.791 times the blood flow rate for the cross-dialyzer clearance measurements at 1 h into dialysis, the mean calculated volume of creatinine distribution averaged 29.6 (SD 7.2) L], compared with 31.6 (SD 7.0) L for urea (P < 0.01). The modeled creatinine generation rate [1183 (SD 463) mg/day] averaged 100.1 % (SD 29; median 99.3) of that predicted in nondialysis patients by an anthropometric equation. A simplified method for modeling the creatinine generation rate using the urea distribution volume and urea dialyzer clearance without use of the postdialysis serum creatinine measurement gave results for creatinine generation rate [1187 (SD 475) mg/day; that closely matched the value calculated using the formally modeled value, R2 = 0.971]. Our analysis confirms previous findings of similar distribution volumes for creatinine and urea. After taking extra-renal clearance into consideration, the creatinine generation rate in dialysis patients is similar to that in nondialysis patients. A simplified method based on urea clearance and urea distribution volume not requiring a postdialysis serum creatinine measurement can be used to yield creatinine generation rates that closely match those determined from standard modeling. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  10. Impact of mechanism vibration characteristics by joint clearance and optimization design of its multi-objective robustness

    NASA Astrophysics Data System (ADS)

    Zeng, Baoping; Wang, Chao; Zhang, Yu; Gong, Yajun; Hu, Sanbao

    2017-12-01

    Joint clearances and friction characteristics significantly influence the mechanism vibration characteristics; for example: as for joint clearances, the shaft and bearing of its clearance joint collide to bring about the dynamic normal contact force and tangential coulomb friction force while the mechanism works; thus, the whole system may vibrate; moreover, the mechanism is under contact-impact with impact force constraint from free movement under action of the above dynamic forces; in addition, the mechanism topology structure also changes. The constraint relationship between joints may be established by a repeated complex nonlinear dynamic process (idle stroke - contact-impact - elastic compression - rebound - impact relief - idle stroke movement - contact-impact). Analysis of vibration characteristics of joint parts is still a challenging open task by far. The dynamic equations for any mechanism with clearance is often a set of strong coupling, high-dimensional and complex time-varying nonlinear differential equations which are solved very difficultly. Moreover, complicated chaotic motions very sensitive to initial values in impact and vibration due to clearance let high-precision simulation and prediction of their dynamic behaviors be more difficult; on the other hand, their subsequent wearing necessarily leads to some certain fluctuation of structure clearance parameters, which acts as one primary factor for vibration of the mechanical system. A dynamic model was established to the device for opening the deepwater robot cabin door with joint clearance by utilizing the finite element method and analysis was carried out to its vibration characteristics in this study. Moreover, its response model was carried out by utilizing the DOE method and then the robust optimization design was performed to sizes of the joint clearance and the friction coefficient change range so that the optimization design results may be regarded as reference data for selecting bearings and controlling manufacturing process parameters for the opening mechanism. Several optimization objectives such as x/y/z accelerations for various measuring points and dynamic reaction forces of mounting brackets, and a few constraints including manufacturing process were taken into account in the optimization models, which were solved by utilizing the multi-objective genetic algorithm (NSGA-II). The vibration characteristics of the optimized opening mechanism are superior to those of the original design. In addition, the numerical forecast results are in good agreement with the test results of the prototype.

  11. Axial compressor gas path design for desensitization of aerodynamic performance and stability to tip clearance

    NASA Astrophysics Data System (ADS)

    Cevik, Mert

    Tip clearance is the necessary small gap left between the moving rotor tip and stationary shroud of a turbomachine. In a compressor, the pressure driven flow through this gap, called tip clearance flow, has a major and generally detrimental impact on compressor performance (pressure ratio and efficiency) and aerodynamic stability (stall margin). The increase in tip clearance, either temporary during transient engine operations or permanent from wear, leads to a drop in compressor performance and aerodynamic stability which results in a fuel consumption increase and a reduced operating envelope for a gas turbine engine. While much research has looked into increasing compressor performance and stall margin at the design (minimum or nominal) tip clearance, very little attention has been paid for reducing the sensitivity of these parameters to tip clearance size increase. The development of technologies that address this issue will lead to aircraft engines whose performance and operating envelope are more robust to operational demands and wear. The current research is the second phase of a research programme to develop design strategies to reduce the sensitivity of axial compressor performance and aerodynamic stability to tip clearance. The first phase had focused on blade design strategies and had led to the discovery and explanation of two flow features that reduces tip sensitivity, namely increased incoming meridional momentum in the rotor tip region and reduction/elimination of double leakage. Double leakage is the flow that exits one tip clearance and enters the tip clearance of the adjacent blade instead of convecting downstream out of the rotor passage. This flow was shown to be very detrimental to compressor performance and stall margin. Two rotor design strategies involving sweep and tip stagger reduction were proposed and shown by CFD simulations to exploit these features to reduce sensitivity. As the second phase, the objectives of the current research project are to develop gas path design strategies for axial compressors to achieve the same goal, to assess their ability to be combined with desensitizing axial compressor blade design strategies and to be applied to non-axial compressors. The search for gas path design strategies was based on the exploitation of the two flow desensitizing features listed above. Two gas path design strategies were proposed and analyzed. The first was gas path contouring in the form of a concave gas path to increase incoming tip meridional momentum.

  12. Total plasma clearance versus urinary plasma clearance of (51)Cr-EDTA in patients with cirrhosis with and without fluid retention.

    PubMed

    Henriksen, Ulrik L; Hansen, Hanne B; Ring-Larsen, Helmer; Bendtsen, Flemming; Henriksen, Jens H

    2015-01-01

    In patients with fluid retention, the total plasma clearance of (51)Cr-EDTA (ClP) may overestimate the glomerular filtration rate (GFR). The present study was therefore undertaken in order to compare ClP with the urinary plasma clearance of (51)Cr-EDTA (ClU) in patients with cirrhosis with and without fluid retention. A total of 136 patients with cirrhosis (24 without fluid retention, 112 with ascites) received a quantitative intravenous injection of (51)Cr-EDTA followed by plasma and quantitative urinary samples for 5 hours. ClP was determined from the injected dose relative to the plasma concentration-time area, extrapolated to infinity. ClU was determined as urinary excretion relative to the plasma concentration-time area up to voiding. In patients without fluid retention, the difference between ClP and ClU (ClP - ClU = ClΔ) was mean 4.5 mL/min/1.73 m(2). In patients with ascites, ClΔ was significantly higher (17.6 mL/min/1.73 m(2), p < 0.0001). ClΔ increased with lower values of GFR (r = - 0.458, p < 0.001). Repeated measurements of ClU in a subgroup of patients with fluid retention (n = 25) gave almost identical values. Different types of corrections of one-pool clearance were almost identical with ClP, except for higher clearance values, which were somewhat underestimated by the former. In patients with fluid retention and ascites ClP and corrected one-pool clearance overestimates GFR substantially. Although ClU may underestimate GFR slightly, patients with ascites should collect urine quantitatively in order to obtain a reliable measurement of GFR.

  13. Enhanced Brain Amyloid-β Clearance by Rifampicin and Caffeine as a Possible Protective Mechanism Against Alzheimer’s Disease

    PubMed Central

    Qosa, Hisham; Abuznait, Alaa H.; Hill, Ronald A.; Kaddoumi, Amal

    2014-01-01

    Rifampicin and caffeine are widely used drugs with reported protective effect against Alzheimer’s disease (AD). However, the mechanism underlying this effect is incompletely understood. In this study, we have hypothesized that enhanced amyloid-β (Aβ) clearance from the brain across the blood-brain barrier (BBB) of wild-type mice treated with rifampicin or caffeine is caused by both drugs potential to upregulate low-density lipoprotein receptor related protein-1 (LRP1) and/or P-glycoprotein (P-gp) at the BBB. Expression studies of LRP1 and P-gp in brain endothelial cells and isolated mice brain microvessels following treatment with rifampicin or caffeine demonstrated both drugs as P-gp inducers, and only rifampicin as an LRP1 inducer. Also, brain efflux index (BEI%) studies conducted on C57BL/6 mice treated with either drug to study alterations in Aβ clearance demonstrated the BEI% of Aβ in rifampicin (82.4 ± 4.3%) and caffeine (80.4 ± 4.8%) treated mice were significantly higher than those of control mice (62.4 ±6.1%, p <0.01). LRP1 and P-gp inhibition studies confirmed the importance of both proteins to the clearance of Aβ, and that enhanced clearance following drugs treatment was caused by LRP1 and/or P-gp upregulation at the mouse BBB. Furthermore, our results provided evidence for the presence of a yet to be identified transporter/receptor that plays significant role in Aβ clearance and is upregulated by caffeine and rifampicin. In conclusion, our results demonstrated the upregulation of LRP1 and P-gp at the BBB by rifampicin and caffeine enhanced brain Aβ clearance, and this effect could explain, at least in part, the protective effect of rifampicin and caffeine against AD. PMID:22504320

  14. Tear clearance and ocular symptoms in patients treated with preservative-free prostaglandins.

    PubMed

    Giménez-Gómez, R; García-Catalán, M R; Gallardo-Galera, J M

    2013-03-01

    To assess the effects on dry eye symptoms and tear dynamics of switching from a prostaglandin with a preservative to a preservative-free prostaglandin. Fourteen patients (N=28 eyes) with open-angle glaucoma and dry eye symptons, treated with preserved latanoprost, travoprost or bimatoprost were included in this uncontrolled prospective study. Ocular symptoms were analysed using a validated ocular surface disease questionnaire and ocular signs were assessed with tear clearance, Schirmer and tear function index test (TFI=Schirmer/clearance). Patients were assigned to preservative-free tafluprost treatment, and measurements were repeated 4 weeks after change of medication. Wilcoxon test and Spearman correlation coefficient were used in the statistical analysis. No statistically significant difference in intraocular pressure (IOP) was observed after switching to tafluprost. Mean IOP at baseline was 20.4 mmHg (SD2.2) and after 4 weeks 19.9 mmHg (SD2.6), (P>.05). The mean questionnaire score significantly decreased from 9.7 (SD3.7) at baseline to 5.4 (SD2.7) after one month (P<.001). No significant differences in tear clearance, Schirmer or TFI were found (P>.05). At baseline, tear clearance=0.13 (SD0.07), Schirmer=10.7 mm (SD6) and TFI=80 (48-156). After 4 weeks, tear clearance=0.1(SD0.07), Schirmer=9.5 mm (3.9) and TFI=104 (48-216). A significant association between questionnaire score and tear clearance after 4 weeks was observed (Spearman coefficient=0.62; P=.014). Switching from preservative prostaglandin with a preservative to preservative-free tafluprost treatment improves dry eye symptoms and suggests an improvement in TFI. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  15. Demographics, socio-behavioral factors, and drug use patterns: what matters in spontaneous HCV clearance?

    PubMed

    Shah, Dimpy P; Grimes, Carolyn Z; Brown, Eric; Hwang, Lu-Yu

    2012-02-01

    Hepatitis C virus (HCV), an emerging bloodborne pathogen, causes chronic liver disease frequently except in about 10-20% of infections which undergo spontaneous resolution. Investigating factors that influence viral clearance is essential to understand the natural history of this infection and establishing novel strategies for prevention and treatment. HCV clearance was estimated in a unique cohort of 1,260 HIV and HBV negative current drug users enrolled for a hepatitis B vaccination study. It was defined as the inability to detect viral RNA using a PCR method in presence of serum anti-HCV antibody EIA. Associated demographic and socio-behavioral factors including drug use patterns were identified from the enrolled subjects using multivariate regression analysis. 33.3% (420/1260) of drug users were found positive for anti-HCV antibodies and 14.8% (62/420) of these individuals achieved viral clearance (negative PCR test). Race or ethnicity of the participants was the only significant factor associated with HCV clearance. Hispanics (OR = 3.4, 95% CI: 1.3-8.5, P = 0.01) and Caucasians (OR = 3.1, 95% CI: 1.5-6.6, P = 0.003) had significantly higher odds of clearing the virus compared to African Americans when adjusted for age and gender. None of the socio-behavioral factors including alcohol intake and drug use patterns were significant determinants of HCV clearance. Racial or ethnic differences in HCV clearance were observed in this study suggesting an important role of host genetic susceptibility factors in determining the clinical course of this disease. Further research is needed to examine these genetic associations of host-virus relationships. Copyright © 2011 Wiley Periodicals, Inc.

  16. Lactate clearance in septic shock is not a surrogate for improved microcirculatory flow

    PubMed Central

    Puskarich, Michael A.; Shapiro, Nathan I.; Massey, Michael J.; Kline, Jeffrey A.; Jones, Alan E.

    2016-01-01

    Introduction Failure to normalize lactate is associated with poor outcomes in septic shock. It has been suggested that persistently elevated lactate may result from regional ischemia due to disturbed and/or heterogenous microcirculatory blood flow. Objectives The goal of this study was to determine if lactate clearance may serve as a surrogate marker for changes in microcirculatory blood flow in patients with septic shock. Methods This was a prospective observational study performed within a previously published clinical trial of L-carnitine for the treatment of vasopressor-dependent septic shock. Intravital video microscopy was performed at enrollment and 12 hours later, and microcirculatory flow index (MFI) was assessed. Associations between enrollment MFI, lactate, and SOFA score were determined, in addition to associations between ΔMFI, lactate clearance, and ΔSOFA. A preplanned subgroup analysis of only patients with an elevated initial lactate was performed. Results We enrolled a total of 31 patients, 23 with survival to and sufficient quality videos both at enrollment and 12 hours. ΔMFI, lactate clearance, and ΔSOFA were 0.1 (IQR 0, 0.3), 18% (IQR −10%, 46%), and −2 (IQR −4, 0). Both ΔMFI and lactate clearance were associated with ΔSOFA (β = −5.3, p = 0.01 and β = −3.5, 0.047), but not with each other, even in the subgroup of patients with an initially elevated lactate. Conclusion We observed no association between degree of lactate clearance and change in microcirculatory blood flow in patients with septic shock. These data suggest against the hypothesis that lactate clearance may be used as a surrogate marker of microcirculatory blood flow. PMID:26825368

  17. Apparently-Different Clearance Rates from Cohort Studies of Mycoplasma genitalium Are Consistent after Accounting for Incidence of Infection, Recurrent Infection, and Study Design.

    PubMed

    Smieszek, Timo; White, Peter J

    2016-01-01

    Mycoplasma genitalium is a potentially major cause of urethritis, cervicitis, pelvic inflammatory disease, infertility, and increased HIV risk. A better understanding of its natural history is crucial to informing control policy. Two extensive cohort studies (students in London, UK; Ugandan sex workers) suggest very different clearance rates; we aimed to understand the reasons and obtain improved estimates by making maximal use of the data from the studies. As M. genitalium is a sexually-transmitted infectious disease, we developed a model for time-to-event analysis that incorporates the processes of (re)infection and clearance, and fitted to data from the two cohort studies to estimate incidence and clearance rates under different scenarios of sexual partnership dynamics and study design (including sample handling and associated test sensitivity). In the London students, the estimated clearance rate is 0.80 p.a. (mean duration 15 months), with incidence 1.31%-3.93% p.a. Without adjusting for study design, corresponding estimates from the Ugandan data are 3.44 p.a. (mean duration 3.5 months) and 58% p.a. Apparent differences in clearance rates are probably mostly due to lower testing sensitivity in the Uganda study due to differences in sample handling, with 'true' clearance rates being similar, and adjusted incidence in Uganda being 28% p.a. Some differences are perhaps due to the sex workers having more-frequent antibiotic treatment, whilst reinfection within ongoing sexual partnerships might have caused some of the apparently-persistent infection in the London students. More information on partnership dynamics would inform more accurate estimates of natural-history parameters. Detailed studies in men are also required.

  18. Hepatitis B and C coinfection in a real-life setting: viral interactions and treatment issues.

    PubMed

    Papadopoulos, Nikolaos; Papavdi, Maria; Pavlidou, Anna; Konstantinou, Dimitris; Kranidioti, Hariklia; Kontos, George; Koskinas, John; Papatheodoridis, George V; Manolakopoulos, Spilios; Deutsch, Melanie

    2018-01-01

    Only limited data concerning hepatitis B (HBV) and C viruses (HCV) coinfection are available. Direct-acting antivirals (DAAs) may be more effective for HCV clearance than interferon (IFN)-based regimens with a risk of HBV reactivation. We retrospectively enrolled 40 HBV/HCV-coinfected patients to evaluate their clinical profile and treatment outcomes. Chronic dual infection was present in 25/40 (62.5%) patients, acute HCV superinfection in 5/40 (12.5%) patients and acute HBV superinfection in 10/40 (25%). Twenty-five patients (62.5%) were treated: 16/25 (64%) with IFN, 4/25 (16%) with nucleot(s)ide analogs (NUCs) and 5/25 (20%) with DAAs. Of the 16 patients treated with IFN-based therapy, 6 (37.5%) achieved both sustained virological response (SVR) and HBsAg clearance. Of the 4 patients treated with NUCs, one (25%) achieved both SVR and HBsAg clearance. All five patients treated with DAAs (100%) achieved SVR, while one case of HBV reactivation was recorded. Fifteen of the 40 patients (37.5%) did not receive any treatment. Eight of them (53.5%) presented with acute HBV superinfection: spontaneous HCV clearance was recorded in 5/8 (62.5%), while HBsAg clearance occurred in 6/8 (75%). Three of them (20%) presented with acute HCV superinfection; spontaneous HCV clearance was recorded in one of the three (33.5%). The other four patients (26.5%) presented with dual HBV/HCV infection. A significant proportion of patients presented with active HBV replication. Treatment with DAAs seems to be efficacious for HCV eradication. However, clinicians should be aware of HBV reactivation. HBV superinfection may lead to both HBsAg and HCV clearance.

  19. Voluntary Exercise Promotes Glymphatic Clearance of Amyloid Beta and Reduces the Activation of Astrocytes and Microglia in Aged Mice

    PubMed Central

    He, Xiao-fei; Liu, Dong-xu; Zhang, Qun; Liang, Feng-ying; Dai, Guang-yan; Zeng, Jin-sheng; Pei, Zhong; Xu, Guang-qing; Lan, Yue

    2017-01-01

    Age is characterized by chronic inflammation, leading to synaptic dysfunction and dementia because the clearance of protein waste is reduced. The clearance of proteins depends partly on the permeation of the blood–brain barrier (BBB) or on the exchange of water and soluble contents between the cerebrospinal fluid (CSF) and the interstitial fluid (ISF). A wealth of evidence indicates that physical exercise improves memory and cognition in neurodegenerative diseases during aging, such as Alzheimer’s disease (AD), but the influence of physical training on glymphatic clearance, BBB permeability and neuroinflammation remains unclear. In this study, glymphatic clearance and BBB permeability were evaluated in aged mice using in vivo two-photon imaging. The mice performed voluntary wheel running exercise and their water-maze cognition was assessed; the expression of the astrocytic water channel aquaporin 4 (AQP4), astrocyte and microglial activation, and the accumulation of amyloid beta (Aβ) were evaluated with immunofluorescence or an enzyme-linked immunosorbent assay (ELISA); synaptic function was investigated with Thy1–green fluorescent protein (GFP) transgenic mice and immunofluorescent staining. Voluntary wheel running significantly improved water-maze cognition in the aged mice, accelerated the efficiency of glymphatic clearance, but which did not affect BBB permeability. The numbers of activated astrocytes and microglia decreased, AQP4 expression increased, and the distribution of astrocytic AQP4 was rearranged. Aβ accumulation decreased, whereas dendrites, dendritic spines and postsynaptic density protein (PSD95) increased. Our study suggests that voluntary wheel running accelerated glymphatic clearance but not BBB permeation, improved astrocytic AQP4 expression and polarization, attenuated the accumulation of amyloid plaques and neuroinflammation, and ultimately protected mice against synaptic dysfunction and a decline in spatial cognition. These data suggest possible mechanisms for exercise-induced neuroprotection in the aging brain. PMID:28579942

  20. Acute Mucociliary Clearance Response to Aerobic Exercise in Smokers.

    PubMed

    Ramos, Ercy M C; Vanderlei, Luiz Carlos M; Ito, Juliana T; Lima, Fabiano F; Rodrigues, Fernanda M M; Manzano, Beatriz M; Fernandes, Rômulo A; Cecílio, Michel J; Toledo-Arruda, Alessandra C; Ramos, Dionei

    2015-11-01

    Mucociliary clearance is the main defense mechanism of the respiratory system, and it is influenced by several stimuli, including aerobic exercise and cigarette smoking. We evaluated the acute response of mucociliary clearance to aerobic exercise in smokers and nonsmokers compared with that found after acute smoking and smoking combined with exercise. Also, we investigated whether there was a correlation between mucociliary clearance and the autonomic nervous system under these conditions. Twenty-one smokers were evaluated for mucociliary clearance by saccharin transit time (STT), and the response of the autonomic nervous system was evaluated by heart rate variability after aerobic exercise, after exercise followed by smoking, after acute smoking, and after rest. For comparison, 17 nonsmokers were also assessed during exercise. Repeated-measures analysis of variance with the Tukey test or the Friedman test followed by the Dunn test was used to evaluate the STT, autonomic response, and other variables to exercise and/or smoking in smokers. A paired t test or Wilcoxon test was used to analyze responses to exercise in nonsmokers. Correlations were evaluated using Pearson or Spearman coefficients. The STT was reduced after exercise in both groups, with similar responses between them. Other stimuli also reduced the STT. The STT showed a negative correlation with sympathetic activity in smokers and a positive correlation with the parasympathetic system in nonsmokers. Although impaired in smokers, mucociliary clearance responded to the stimulus of exercise, as demonstrated by similar STTs compared with nonsmokers. This response was correlated with the autonomic nervous system in both groups. In smokers, mucociliary clearance also responded to the stimuli of smoking and exercise followed by smoking. Copyright © 2015 by Daedalus Enterprises.

  1. Natural cellular resistance of beige mice against Cryptococcus neoformans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hidore, M.R.; Murphy, J.W.

    Previous reports have demonstrated that natural killer (NK) cells are capable of inhibiting the growth of Cryptococcus neoformans in vitro, and recent studies indicate that adoptively transferred NK cell-enriched spleen cell populations enhance clearance of cryptococci from the tissues of cyclophosphamide-pretreated recipients. The primary objective of these studies was to confirm that NK cells participate in early clearance of C. neoformans in vivo. Secondarily, the anti-cryptococcal activities of polymorphonuclear leukocytes and macrophages were examined. Seven-week-old C57BL/6 bg/+ mice, which have normal levels of NK cell activity, were compared with their bg/bg littermates, which have impaired NK cell function. One andmore » 3 days after injecting both groups of mice i.v. with 2 x 10/sup 4/ cryptococci, the authors assessed the NK cell activities in spleens, lungs, and livers and clearance of the organism from corresponding tissues as determined by the mean log/sub 1//sup 0/ numbers of cryptococcal colony-forming units (CFU) per organ. Although the data indicated a correlation between early clearance of cryptococci from tissues and levels of NK cell activities in the corresponding tissues, it was also possible that differences in phagocytic cell function between the bg/+ and bg/bg animals could account for the observed differences in clearance of cryptococci from the tissues. These data indicate that NK cells were the effector cells responsible for enhanced early clearance of cryptococci from the tissues of bg/+ animals when compared with clearance from the tissues of the bg/bg littermates. Furthermore, they confirm the hypothesis that NK cells can affect C. neoformans under in vivo conditions.« less

  2. Population pharmacokinetics of telapristone (CDB-4124) and its active monodemethylated metabolite CDB-4453, with a mixture model for total clearance.

    PubMed

    Morris, Denise; Podolski, Joseph; Kirsch, Alan; Wiehle, Ronald; Fleckenstein, Lawrence

    2011-12-01

    Telapristone is a selective progesterone antagonist that is being developed for the long-term treatment of symptoms associated with endometriosis and uterine fibroids. The population pharmacokinetics of telapristone (CDB-4124) and CDB-4453 was investigated using nonlinear mixed-effects modeling. Data from two clinical studies (n = 32) were included in the analysis. A two-compartment (parent) one compartment (metabolite) mixture model (with two populations for apparent clearance) with first-order absorption and elimination adequately described the pharmacokinetics of telapristone and CDB-4453. Telapristone was rapidly absorbed with an absorption rate constant (Ka) of 1.26 h(-1). Moderate renal impairment resulted in a 74% decrease in Ka. The population estimates for oral clearance (CL/F) for the two populations were 11.6 and 3.34 L/h, respectively, with 25% of the subjects being allocated to the high-clearance group. Apparent volume of distribution for the central compartment (V2/F) was 37.4 L, apparent inter-compartmental clearance (Q/F) was 21.9 L/h, and apparent peripheral volume of distribution for the parent (V4/F) was 120 L. The ratio of the fraction of telapristone converted to CDB-4453 to the distribution volume of CDB-4453 (Fmet(est)) was 0.20/L. Apparent volume of distribution of the metabolite compartment (V3/F) was fixed to 1 L and apparent clearance of the metabolite (CLM/F) was 2.43 L/h. A two-compartment parent-metabolite model adequately described the pharmacokinetics of telapristone and CDB-4453. The clearance of telapristone was separated into two populations and could be the result of metabolism via polymorphic CYP3A5.

  3. MO-F-16A-08: Have An Impact On More Patients From Your Ideas And Inventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morton, R

    Purpose: To inform physicists how to obtain an FDA 510(k) clearance for the innovations they use in their facility and to make those ideas widely available to patients throughout the U.S. Methods: Give advice from 20 years experience of assisting in well over 100 successful 510(k) clearances. Results: Learn how to develop a 510(k) submission. Conclusion: Many physicists, physicians and radiation therapists have developed innovations that that are helpful to the patients in their institution. But, many of these innovations deserve to be made available to patients throughout the United States. The author, a Certified Radiological Physicist and former FDAmore » employee, has consulted for over twenty years for inventors, start-ups and established medical device manufacturers to bring new devices to market in the U.S. and to assist them to established FDA compliant quality systems for manufacturing. In this presentation the audience will learn the important points for deciding to go forward with obtaining a Premarket Notification clearance [also known as a 510(k) clearance] to legally market a medical device in the United States. The FDA has published guidelines for submitting a 510(k) application. However, the methods used to efficiently develop the documentation for submission and to obtain clearance in the shortest possible time comes from the author's experience in assisting well over one hundred successful 510(k) clearances.Whether you want to start your own company or to market your idea to an established medical device manufacturer, the value of your innovation increases with a documented 510(k) clearance from FDA.« less

  4. Triglyceride enrichment of HDL enhances in vivo metabolic clearance of HDL apo A-I in healthy men

    PubMed Central

    Lamarche, Benoît; Uffelman, Kristine D.; Carpentier, André; Cohn, Jeffrey S.; Steiner, George; Barrett, P. Hugh; Lewis, Gary F.

    1999-01-01

    Triglyceride (TG) enrichment of HDL resulting from cholesteryl ester transfer protein–mediated exchange with TG-rich lipoproteins may enhance the lipolytic transformation and subsequent metabolic clearance of HDL particles in hypertriglyceridemic states. The present study investigates the effect of TG enrichment of HDL on the clearance of HDL-associated apo A-I in humans. HDL was isolated from plasma of six normolipidemic men (mean age: 29.7 ± 2.7 years) in the fasting state and after a five-hour intravenous infusion with a synthetic TG emulsion, Intralipid. Intralipid infusion resulted in a 2.1-fold increase in the TG content of HDL. Each tracer was then whole-labeled with 125I or 131I and injected intravenously into the subject. Apo A-I in TG-enriched HDL was cleared 26% more rapidly than apo A-I in fasting HDL. A strong correlation between the Intralipid-induced increase in the TG content of HDL and the increase in HDL apo A-I fractional catabolic rate reinforced the importance of TG enrichment of HDL in enhancing its metabolic clearance. HDL was separated further into lipoproteins containing apo A-II (LpAI:AII) and those without apo A-II (LpAI). Results revealed that the enhanced clearance of apo A-I from TG-enriched HDL could be largely attributed to differences in the clearance of LpAI but not LpAI:AII. This is, to our knowledge, the first direct demonstration in humans that TG enrichment of HDL enhances the clearance of HDL apo A-I from the circulation. This phenomenon could provide an important mechanism explaining how HDL apo A-I and HDL cholesterol are lowered in hypertriglyceridemic states. PMID:10207171

  5. Interactions Among Drinking and Ground Water Contaminants on Renal and Hepatic Function

    DTIC Science & Technology

    1988-07-25

    inulin . The change was more pronounced in the saline group, because the MCA + oil group had a somewhat diminished GFR. There were no significant effects...flow rate were not affected by MCA, VDC or the combined treatment. ftEMALES VDC decreased GFR, assessed as clearance of inulin , in both saline and MCA...apparently disparate, they are in agreement with the known relationship between renal function assessed by inulin clearance and lack of clearance of

  6. High-Speed, capacitance-based tip clearance sensing

    NASA Astrophysics Data System (ADS)

    Haase, W. C.; Haase, Z. S.

    This paper discusses recent advances in tip clearance measurement systems for turbine engines using capacitive probes. Real time measurements of individual blade pulses are generated using wideband signal processing providing 3 dB bandwidths of typically 5 MHz. Subsequent mixed-signal processing circuitry provide real-time measurements of maximum, minimum, and average clearance with latencies of one blade-to-blade time interval. Both guarded and unguarded probe configurations are possible with the system. Calibration techniques provide high accuracy measurements.

  7. [The respiratory system--its self-cleaning system. General mechanisms of clearance].

    PubMed

    Mustajbegović, J; Zuskin, E

    1998-01-01

    The behaviour of particles and deposition in different parts of respiratory system are described. Listed are factors which contribute to the deposition of particles in the lungs and upper areas of the respiratory system. The general mechanisms of lung clearance and their action such as cough, mucociliary transport, alveolar clearance and immunological system are reported. Particularly is stressed the necessity of coordination of all defense mechanisms in order to maintain normal respiratory function.

  8. B747/JT9D flight loads and their effect on engine running clearances and performance deterioration; BCAC NAIL/P and WA JT9D engine diagnostics programs

    NASA Technical Reports Server (NTRS)

    Olsson, W. J.; Martin, R. L.

    1982-01-01

    Flight loads on the 747 propulsion system and resulting JT9D blade to outer airseal running clearances during representative acceptance flight and revenue flight sequences were measured. The resulting rub induced clearance changes, and engine performance changes were then analyzed to validate and refine the JT9D-7A short term performance deterioration model.

  9. Hepatic and muscle clearance of physostigmine in the rat after i. v. administration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Somani, S.M.; Unni, L.K.

    1986-03-01

    This study presents a method to calculate the extraction ratio (ER) from in vivo time course of liver metabolism using the physiological and pharmacokinetic parameters such as plasma flow rate, partition coefficient of drug between tissue and plasma and the elimination rate constant from tissues. Rats were administered /sup 3/H-physostigmine (Phy), 100 ..mu..g/kg i.v.; and were sacrificed at various times. Tissues were removed and Phy and its metabolites were determined by HPLC. Half-life of Phy in liver and muscle was 24 and 20 min, respectively. ER of Phy in liver was .71 which showed a slight decrease at 10 min.more » Muscle ER was found to be .347 up to 5 min. Hepatic clearance was calculated to be 23.08 ml/min/kg (34.9% of systemic clearance) and the intrinsic clearance was 83.73 ml/min/kg which indicates that the changes in blood flow to the liver can cause a variation in the systematic clearance. Percentage dose of Phy retained in muscle was maximum and the clearance was 5.2 ml/min/kg suggesting that muscle might be acting as a storage depot for Phy prolonging the pharmacological effects. About 30-40% of radioactivity in the liver could not be washed off by 10% TCA or organic solvents indicating the irreversible binding of drug or metabolite to liver macromolecule.« less

  10. Use of CFD Analyses to Predict Disk Friction Loss of Centrifugal Compressor Impellers

    NASA Astrophysics Data System (ADS)

    Cho, Leesang; Lee, Seawook; Cho, Jinsoo

    To improve the total efficiency of centrifugal compressors, it is necessary to reduce disk friction loss, which is expressed as the power loss. In this study, to reduce the disk friction loss due to the effect of axial clearance and surface roughness is analyzed and methods to reduce disk friction loss are proposed. The rotating reference frame technique using a commercial CFD tool (FLUENT) is used for steady-state analysis of the centrifugal compressor. Numerical results of the CFD analysis are compared with theoretical results using established experimental empirical equations. The disk friction loss of the impeller is decreased in line with increments in axial clearance until the axial clearance between the impeller disk and the casing is smaller than the boundary layer thickness. In addition, the disk friction loss of the impeller is increased in line with the increments in surface roughness in a similar pattern as that of existing experimental empirical formulas. The disk friction loss of the impeller is more affected by the surface roughness than the change of the axial clearance. To minimize disk friction loss on the centrifugal compressor impeller, the axial clearance and the theoretical boundary layer thickness should be designed to be the same. The design of the impeller requires careful consideration in order to optimize axial clearance and minimize surface roughness.

  11. An enhanced flexible dynamic model and experimental verification for a valve train with clearance and multi-directional deformations

    NASA Astrophysics Data System (ADS)

    Zhou, Changjiang; Hu, Bo; Chen, Siyu; He, Liping

    2017-12-01

    An enhanced flexible dynamic model for a valve train with clearance and multi-directional deformations is proposed based on finite element method (FEM), and verified by experiment. According to the measured cam profile, the available internal excitations in numerical solution to the model are achieved by using piecewise cubic Hermite interpolating polynomial. The comparative analysis demonstrates that the bending deformation of the rocker arm is much larger than the radial deformation, signifying the necessities of multi-directional deformations in dynamic analysis for the valve train. The effects of valve clearance and cam rotation speed on contact force, acceleration and dynamic transmission error (DTE) are investigated. Both theoretical predictions and experimental measurements show that the amplitudes and fluctuations of contact force, acceleration and DTE become larger, when the valve clearance or cam speed increases. It is found that including the elasticity and the damping will weaken the impact between the rocker arm and the valve on the components (not adjacent to the valve) at either unseating or seating scenario. Additionally, as valve clearance or cam rotation speed becomes larger, the valve lift and the working phase decrease, which eventually leads to inlet air reduction. Furthermore, our study shows that the combustion rate improvement, input torque, and components durability can be improved by tuning valve clearance or adjustment the cam profile.

  12. Proposal of a pharmacokinetically optimized dosage regimen of antibiotics in patients receiving continuous hemodiafiltration.

    PubMed

    Yamamoto, Takehito; Yasuno, Nobuhiro; Katada, Shoichi; Hisaka, Akihiro; Hanafusa, Norio; Noiri, Eisei; Yahagi, Naoki; Fujita, Toshiro; Suzuki, Hiroshi

    2011-12-01

    The aim of the study was to quantitatively predict the clearance of three antibiotics, amikacin, vancomycin, and teicoplanin, during continuous hemodiafiltration (CHDF) and to propose their optimal dosage in patients receiving CHDF. For this goal, in vitro CHDF experiments with a polyacrylonitrile (PAN) membrane were first performed using these antibiotics, and then the clearances were compared with in vivo CHDF situations determined in 16 critically ill patients. The in vitro CHDF clearances were described as the product of the outflow rate of a drain (Q(outflow)) and the drug unbound fraction in artificial plasma, indicating that drug adsorption to the PAN membrane has minor effect on drug clearance in our settings. The observed in vivo clearances also agreed very well with the predicted values, with a product of Q(outflow) and plasma unbound fraction, when residual creatinine clearance (CL(CR)) was taken into account (within a range of 0.67- to 1.5-fold for 15 of 16 patients). Based on these results, a nomogram of the optimized dosages of amikacin, vancomycin, and teicoplanin was proposed, and it was evident that Q(outflow) and residual CL(CR) are major determinants of the dosage and dosing interval for these antibiotics. Although the applicability needs to be confirmed with another type of membrane or higher Q(outflow), our nomogram can help determine the dosage setting in critically ill patients receiving CHDF.

  13. Limitations of the hCMEC/D3 cell line as a model for Aβ clearance by the human blood-brain barrier.

    PubMed

    Biemans, Elisanne A L M; Jäkel, Lieke; de Waal, Robert M W; Kuiperij, H Bea; Verbeek, Marcel M

    2017-07-01

    Alzheimer's disease and cerebral amyloid angiopathy are characterized by accumulation of amyloid-β (Aβ) at the cerebrovasculature due to decreased clearance at the blood-brain barrier (BBB). However, the exact mechanism of Aβ clearance across this barrier has not been fully elucidated. The hCMEC/D3 cell line has been characterized as a valid model for the BBB. In this study we evaluated the use of this model to study Aβ clearance across the BBB, with an emphasis on brain-to-blood directional permeability. Barrier integrity of hCMEC/D3 monolayers was confirmed for large molecules in both the apical to basolateral and the reverse direction. However, permeability for smaller molecules was substantially higher, especially in basolateral to apical direction, and barrier formation for Aβ was completely absent in this direction. In addition, hCMEC/D3 cells failed to develop a high TEER, possibly caused by incomplete formation of tight junctions. We conclude that the hCMEC/D3 model has several limitations to study the cerebral clearance of Aβ. Therefore, the model needs further characterization before this cell system can be generally applied as a model to study cerebral Aβ clearance. © 2016 The Authors Journal of Neuroscience Research Published by Wiley Periodicals, Inc. © 2016 The Authors Journal of Neuroscience Research Published by Wiley Periodicals, Inc.

  14. Stainless steel manual metal arc welding fumes in rats.

    PubMed Central

    Kalliomäki, P L; Lakomaa, E; Kalliomäki, K; Kiilunen, M; Kivelä, R; Vaaranen, V

    1983-01-01

    Forty two male Wistar rats were exposed to manual metal arc (MMA) stainless steel (SS) welding fumes generated by an automatic welding device for "nose-only" exposure. The exposure simulated an actual MMA/SS welding environment as closely as possible. For the retention study, the duration of exposure was one hour per workday for one, two, three, of four weeks and for the clearance study four weeks. The retention and clearance of the chromium, nickel, and iron found in MMA/SS welding fumes in the rats' lungs were studied as was the distribution of the metals to other organs. Instrumental neutron activation analysis (INAA) was used for the multi-element chemical activation analyses. The concentrations of chromium and nickel in the blood and the urine were determined by atomic absorption method (AAS). The retention of exogenous iron was determined by a magnetic measuring method. The results indicated that the lungs were the target organs of soluble hexavalent chromates. The half times of lung clearance for Cr, Ni, and Fe were 40 +/- 4 d, 20 +/- d, and 50 +/- 10 d. When the lung clearance curves are compared, the half times of Cr and Fe lung clearance are similar but nickel disappears faster. The distribution and clearance patterns of chromium to other organs differ from those obtained after single intravenous or intratracheal injections of alkaline chromates. PMID:6830723

  15. Circadian Clearance of a Fungal Pathogen from the Lung Is Not Based on Cell-intrinsic Macrophage Rhythms.

    PubMed

    Chen, Shan; Fuller, Kevin K; Dunlap, Jay C; Loros, Jennifer J

    2018-02-01

    Circadian rhythms govern immune cell function, giving rise to time-of-day variation in the recognition and clearance of bacterial or viral pathogens; to date, however, no such regulation of the host-fungal interaction has been described. In this report, we use murine models to explore circadian control of either fungal-macrophage interactions in vitro or pathogen clearance from the lung in vivo. First, we show that expression of the important fungal pattern recognition receptor Dectin-1 ( clec7a), from either bone marrow-derived or peritoneum-derived macrophages, is not under circadian regulation at either the level of transcript or cell surface protein expression. Consistent with this finding, the phagocytic activity of macrophages in culture against spores of the pathogen Aspergillus fumigatus also did not vary over time. To account for the multiple cell types and processes that may be coordinated in a circadian fashion in vivo, we examined the clearance of A. fumigatus from the lungs of immunocompetent mice. Interestingly, animals inoculated at night demonstrated a 2-fold enhancement in clearance compared with animals inoculated in the morning. Taken together, our data suggest that while molecular recognition of fungi by immune cells may not be circadian, other processes in vivo may still allow for time-of-day differences in fungal clearance from the lung.

  16. Omega-3 polyunsaturated fatty acids promote amyloid-β clearance from the brain through mediating the function of the glymphatic system.

    PubMed

    Ren, Huixia; Luo, Chuanming; Feng, Yanqing; Yao, Xiaoli; Shi, Zhe; Liang, Fengyin; Kang, Jing X; Wan, Jian-Bo; Pei, Zhong; Su, Huanxing

    2017-01-01

    Impairment of amyloid-β (Aβ) clearance leads to Aβ accumulation in the brain during the development of Alzheimer's disease (AD). Strategies that can restore or improve the clearance function hold great promise in delaying or preventing the onset of AD. Here, we show that n-3 polyunsaturated fatty acids (PUFAs), by use of fat-1 transgenic mice and oral administration of fish oil, significantly promote interstitial Aβ clearance from the brain and resist Aβ injury. Such beneficial effects were abolished in Aqp4-knockout mice, suggesting that the AQP4-dependent glymphatic system is actively involved in the promoting the effects of n-3 PUFAs on the clearance of extracellular Aβ. Imaging on clarified brain tissues clearly displayed that n-3 PUFAs markedly inhibit the activation of astrocytes and protect the AQP4 polarization in the affected brain region after Aβ injection. The results of the present study prove a novel mechanism by which n-3 PUFAs exert protective roles in reducing Aβ accumulation via mediating the glymphatic system function.-Ren, H., Luo, C., Feng, Y., Yao, X., Shi, Z., Liang, F., Kang, J. X., Wan, J.-B., Pei, Z., Su, H. Omega-3 polyunsaturated fatty acids promote amyloid-β clearance from the brain through mediating the function of the glymphatic system. © FASEB.

  17. Effects of lighting illuminance levels on stair negotiation performance in individuals with visual impairment.

    PubMed

    Shaheen, Aliah F; Sourlas, Alexandros; Horton, Khim; McLean, Christopher; Ewins, David; Gould, David; Ghoussayni, Salim

    2018-04-01

    Stair-related falls of older people cause a substantial financial and social burden. Deterioration of the visual system amongst other factors put older people at a high risk of falling. Improved lighting is often recommended. The aim of this study was to investigate the effect of lighting illuminance on stair negotiation performance in older individuals with visual impairment. Eleven participants aged 60 or over with a vision of 6/18 or worse ascended and descended a staircase under: 50 lx, 100 lx, 200 lx, 300 lx and distributed 200 lx lighting. A motion capture system was used to measure movements of the lower limb. Clearance, clearance variability, temporal and spatial parameters and joint/segment kinematics were computed. There was no effect on clearance or clearance variability. Participants had lower speed, cadence, increased cycle time and stance time in the 50 lx compared to 300 lx and distributed 200 lx lighting in descent. The minimum hip angle in ascent was increased in the 200 lx lighting. Clearance was found to be moderately correlated with balance scores. Individuals with visual impairment adopt precautionary gait in dim lighting conditions. This does not always result in improvements in the parameters associated with risk of falling (e.g. clearance). Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. An Investigation of Flight Deck Data Link in the Terminal Area

    NASA Technical Reports Server (NTRS)

    Martin, Lynne; Lozito, Sandra; Kaneshige, John; Dulchinos, Vicki; Sharma, Shivanjli

    2013-01-01

    The Next Generation Air Transportation System (NextGen) and Europe's Single European Sky ATM Research (SESAR) concepts require an increased use of trajectory-based operations, including extensive strategic air traffic control clearances. The clearances are lengthy and complex, which necessitate data link communications to allow for message permanence and integration into the autoflight systems (i.e., autoload capability). This paper examines the use of flight deck data link communications for strategic and tactical clearance usage in the terminal area. A human-in-the-loop simulation was conducted using a high-fidelity flight deck simulator, with ten commercial flight crews as participants. Data were collected from six flight scenarios in the San Francisco terminal airspace. The variables of interest were ATC message modality (voice v. data link), temporal quality of the message (tactical v. strategic) and message length. Dependent variables were message response times, communication clarifications, communication-related errors, and pilot workload. Response time results were longer in data link compared to voice, a finding that has been consistently revealed in a number of other simulations [1]. In addition, strategic clearances and longer messages resulted in a greater number of clarifications and errors, suggesting an increase in uncertainty of message interpretation for the flight crews when compared to tactical clearances. The implications for strategic and compound clearance usage in NextGen and SESAR are discussed

  19. SIGN-R1 and complement factors are involved in the systemic clearance of radiation-induced apoptotic cells in whole-body irradiated mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Jin-Yeon; Loh, SoHee; Cho, Eun-hee

    Although SIGN-R1-mediated complement activation pathway has been shown to enhance the systemic clearance of apoptotic cells, the role of SIGN-R1 in the clearance of radiation-induced apoptotic cells has not been characterized and was investigated in this study. Our data indicated that whole-body γ-irradiation of mice increased caspase-3{sup +} apoptotic lymphocyte numbers in secondary lymphoid organs. Following γ-irradiation, SIGN-R1 and complements (C4 and C3) were simultaneously increased only in the mice spleen tissue among the assessed tissues. In particular, C3 was exclusively activated in the spleen. The delayed clearance of apoptotic cells was markedly prevalent in the spleen and liver ofmore » SIGN-R1 KO mice, followed by a significant increase of CD11b{sup +} cells. These results indicate that SIGN-R1 and complement factors play an important role in the systemic clearance of radiation-induced apoptotic innate immune cells to maintain tissue homeostasis after γ-irradiation. - Highlights: • Splenic SIGN-R1{sup +} macrophages are activated after γ-irradiation. • C3 and C4 levels increased and C3 was activated in the spleen after γ-irradiation. • SIGN-R1 mediated the systemic clearance of radiation-induced apoptotic cells in spleen and liver.« less

  20. Blood lactate clearance after maximal exercise depends on active recovery intensity.

    PubMed

    Devlin, J; Paton, B; Poole, L; Sun, W; Ferguson, C; Wilson, J; Kemi, O J

    2014-06-01

    High-intensity exercise is time-limited by onset of fatigue, marked by accumulation of blood lactate. This is accentuated at maximal, all-out exercise that rapidly accumulates high blood lactate. The optimal active recovery intensity for clearing lactate after such maximal, all-out exercise remains unknown. Thus, we studied the intensity-dependence of lactate clearance during active recovery after maximal exercise. We constructed a standardized maximal, all-out treadmill exercise protocol that predictably lead to voluntary exhaustion and blood lactate concentration>10 mM. Next, subjects ran series of all-out bouts that increased blood lactate concentration to 11.5±0.2 mM, followed by recovery exercises ranging 0% (passive)-100% of the lactate threshold. Repeated measurements showed faster lactate clearance during active versus passive recovery (P<0.01), and that active recovery at 60-100% of lactate threshold was more efficient for lactate clearance than lower intensity recovery (P<0.05). Active recovery at 80% of lactate threshold had the highest rate of and shortest time constant for lactate clearance (P<0.05), whereas the response during the other intensities was graded (100%=60%>40%>passive recovery, P<0.05). Active recovery after maximal all-out exercise clears accumulated blood lactate faster than passive recovery in an intensity-dependent manner, with maximum clearance occurring at active recovery of 80% of lactate threshold.

Top