Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan.
Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng
2013-11-01
To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) "Regulations on Clearance Level for Radioactive Waste Management". The testing results should conform to the deviation and traceability requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-05
... settlement of litigation over certain post- renovation cleaning requirements of the 2008 Lead Renovation... work practice standards for persons performing renovations for compensation in most pre-1978 housing... it to a recognized laboratory for analysis in lieu of using a lead test kit, minor changes to the...
30 CFR 27.36 - Test for adequacy of electrical insulation and clearances.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Test for adequacy of electrical insulation and clearances. 27.36 Section 27.36 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test Requirements § 27.36...
30 CFR 27.36 - Test for adequacy of electrical insulation and clearances.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Test for adequacy of electrical insulation and clearances. 27.36 Section 27.36 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test Requirements § 27.36...
Qiu, Jinshu; Li, Kim; Miller, Karen; Raghani, Anil
2015-01-01
The purpose of this article is to recommend a risk-based strategy for determining clearance testing requirements of the process reagents used in manufacturing biopharmaceutical products. The strategy takes account of four risk factors. Firstly, the process reagents are classified into two categories according to their safety profile and history of use: generally recognized as safe (GRAS) and potential safety concern (PSC) reagents. The clearance testing of GRAS reagents can be eliminated because of their safe use historically and process capability to remove these reagents. An estimated safety margin (Se) value, a ratio of the exposure limit to the estimated maximum reagent amount, is then used to evaluate the necessity for testing the PSC reagents at an early development stage. The Se value is calculated from two risk factors, the starting PSC reagent amount per maximum product dose (Me), and the exposure limit (Le). A worst-case scenario is assumed to estimate the Me value, that is common. The PSC reagent of interest is co-purified with the product and no clearance occurs throughout the entire purification process. No clearance testing is required for this PSC reagent if its Se value is ≥1; otherwise clearance testing is needed. Finally, the point of the process reagent introduction to the process is also considered in determining the necessity of the clearance testing for process reagents. How to use the measured safety margin as a criterion for determining PSC reagent testing at process characterization, process validation, and commercial production stages are also described. A large number of process reagents are used in the biopharmaceutical manufacturing to control the process performance. Clearance testing for all of the process reagents will be an enormous analytical task. In this article, a risk-based strategy is described to eliminate unnecessary clearance testing for majority of the process reagents using four risk factors. The risk factors included in the strategy are (i) safety profile of the reagents, (ii) the starting amount of the process reagents used in the manufacturing process, (iii) the maximum dose of the product, and (iv) the point of introduction of the process reagents in the process. The implementation of the risk-based strategy can eliminate clearance testing for approximately 90% of the process reagents used in the manufacturing processes. This science-based strategy allows us to ensure patient safety and meet regulatory agency expectations throughout the product development life cycle. © PDA, Inc. 2015.
Code of Federal Regulations, 2011 CFR
2011-07-01
... at the flame-arresting portion might require such machining. (4) Ball and roller bearings and oil... clearance(s) shall conform to the requirements of § 18.31. (6) Oil seals shall be removed from motors prior to submission for explosion tests. Note: Oil seals will be removed from motors prior to explosion...
Code of Federal Regulations, 2012 CFR
2012-07-01
... at the flame-arresting portion might require such machining. (4) Ball and roller bearings and oil... clearance(s) shall conform to the requirements of § 18.31. (6) Oil seals shall be removed from motors prior to submission for explosion tests. Note: Oil seals will be removed from motors prior to explosion...
Code of Federal Regulations, 2013 CFR
2013-07-01
... at the flame-arresting portion might require such machining. (4) Ball and roller bearings and oil... clearance(s) shall conform to the requirements of § 18.31. (6) Oil seals shall be removed from motors prior to submission for explosion tests. Note: Oil seals will be removed from motors prior to explosion...
Code of Federal Regulations, 2014 CFR
2014-07-01
... at the flame-arresting portion might require such machining. (4) Ball and roller bearings and oil... clearance(s) shall conform to the requirements of § 18.31. (6) Oil seals shall be removed from motors prior to submission for explosion tests. Note: Oil seals will be removed from motors prior to explosion...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-07
... Program Chemicals Division, Office of Pollution Prevention and Toxics, Environmental Protection Agency.... Owens, Assistant Administrator, Office of Chemical Safety and Pollution Prevention. [FR Doc. 2010-16657...
Advanced optical blade tip clearance measurement system
NASA Technical Reports Server (NTRS)
Ford, M. J.; Honeycutt, R. E.; Nordlund, R. E.; Robinson, W. W.
1978-01-01
An advanced electro-optical system was developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in an operating gas turbine engine. This system is applicable to fan, compressor, and turbine blade tip clearance measurement requirements, and the system probe is particularly suitable for operation in the extreme turbine environment. A study of optical properties of blade tips was conducted to establish measurement system application limitations. A series of laboratory tests was conducted to determine the measurement system's operational performance characteristics and to demonstrate system capability under simulated operating gas turbine environmental conditions. Operational and environmental performance test data are presented.
DataComm in Flight Deck Surface Trajectory-Based Operations
NASA Technical Reports Server (NTRS)
Bakowski, Deborah L.; Foyle, David C.; Hooey, Becky L.; Meyer, Glenn R.; Wolter, Cynthia A.
2012-01-01
The purpose of this pilot-in-the-loop aircraft taxi simulation was to evaluate a NextGen concept for surface trajectory-based operations (STBO) in which air traffic control (ATC) issued taxi clearances with a required time of arrival (RTA) by Data Communications (DataComm). Flight deck avionics, driven by an error-nulling algorithm, displayed the speed needed to meet the RTA. To ensure robustness of the algorithm, the ability of 10 two-pilot crews to meet the RTA was tested in nine experimental trials representing a range of realistic conditions including a taxi route change, an RTA change, a departure clearance change, and a crossing traffic hold scenario. In some trials, these DataComm taxi clearances or clearance modifications were accompanied by 'preview' information, in which the airport map display showed a preview of the proposed route changes, including the necessary speed to meet the RTA. Overall, the results of this study show that with the aid of the RTA speed algorithm, pilots were able to meet their RTAs with very little time error in all of the robustness-testing scenarios. Results indicated that when taxi clearance changes were issued by DataComm only, pilots required longer notification distances than with voice communication. However, when the DataComm was accompanied by graphical preview, the notification distance required by pilots was equivalent to that for voice.
DataComm in Flight Deck Surface Trajectory-Based Operations. Chapter 20
NASA Technical Reports Server (NTRS)
Bakowski, Deborah L.; Foyle, David C.; Hooey, Becky L.; Meyer, Glenn R.; Wolter, Cynthia A.
2012-01-01
The purpose of this pilot-in-the-loop aircraft taxi simulation was to evaluate a NextGen concept for surface trajectory-based operations (STBO) in which air traffic control (ATC) issued taxi clearances with a required time of arrival (RTA) by Data Communications (DataComm). Flight deck avionics, driven by an error-nulling algorithm, displayed the speed needed to meet the RTA. To ensure robustness of the algorithm, the ability of 10 two-pilot crews to meet the RTA was tested in nine experimental trials representing a range of realistic conditions including a taxi route change, an RTA change, a departure clearance change, and a crossing traffic hold scenario. In some trials, these DataComm taxi clearances or clearance modifications were accompanied by preview information, in which the airport map display showed a preview of the proposed route changes, including the necessary speed to meet the RTA. Overall, the results of this study show that with the aid of the RTA speed algorithm, pilots were able to meet their RTAs with very little time error in all of the robustness-testing scenarios. Results indicated that when taxi clearance changes were issued by DataComm only, pilots required longer notification distances than with voice communication. However, when the DataComm was accompanied by graphical preview, the notification distance required by pilots was equivalent to that for voice.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-06
.... Other technical and trade schools (NAICS code 611519), e.g., training providers. Engineering services... Renovation, Repair, and Painting Program (RRP) rule that established accreditation, training, certification... operate a training program for individuals who perform any of these activities. ``Target housing'' is...
Immune Mediators of Rotavirus Antigenemia Clearance in Mice ▿
Marcelin, Glendie; Miller, Amber D.; Blutt, Sarah E.; Conner, Margaret E.
2011-01-01
The immunological mediators that clear rotavirus antigenemia or viremia remain undefined. Immunodeficient mice and antibody transfer were used to test whether lymphocytes or rotavirus-specific serum antibodies are essential for resolving antigenemia. Clearance of antigenemia required lymphocytes, but neither T nor B lymphocytes were absolutely required. Transfer of convalescent-phase or nonneutralizing rotavirus-specific serum antibodies to the systemic compartment of severe-combined-immunodeficient (SCID) mice temporarily suppressed the onset or level of chronic rotavirus antigenemia. Our findings provide the first report demonstrating that clearance of rotavirus antigenemia and possibly viremia are mediated by multiple effector lymphocyte subsets and serum antibodies. PMID:21593155
Mikrut, Sławomir; Kohut, Piotr; Pyka, Krystian; Tokarczyk, Regina; Barszcz, Tomasz; Uhl, Tadeusz
2016-01-01
The paper contains a survey of mobile scanning systems for measuring the railway clearance gauge. The research was completed as part of the project carried out for the PKP (PKP Polish Railway Lines S.A., Warsaw, Poland) in 2011–2013. The authors conducted experiments, including a search for the latest solutions relating to mobile measurement systems that meet the basic requirement. At the very least, these solutions needed to be accurate and have the ability for quick retrieval of data. In the paper, specifications and the characteristics of the component devices of the scanning systems are described. Based on experiments, the authors did some examination of the selected mobile systems to be applied for measuring the clearance gauge. The Riegl (VMX-250) and Z+F (Zoller + Fröhlich) Solution were tested. Additional test measurements were carried out within a 30-kilometer section of the Warsaw-Kraków route. These measurements were designed so as to provide various elements of the railway infrastructure, the track geometry and the installed geodetic control network. This ultimately made it possible to reduce the time for the preparation of geodetic reference measurements for the testing of the accuracy of the selected systems. Reference measurements included the use of the polar method to select profiles perpendicular to the axis of the track. In addition, the coordinates selected were well defined as measuring points of the objects of the infrastructure of the clearance gauge. All of the tested systems meet the accuracy requirements initially established (within the range of 2 cm as required by the PKP). The tested systems have shown their advantages and disadvantages. PMID:27187400
Seal Investigations of an Active Clearance Control System Concept
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M.; Taylor, Shawn; Oswald, Jay; DeCastro, Jonathan A.
2006-01-01
In an effort to improve upon current thermal active clearance control methods, a first generation, fast-acting mechanically actuated, active clearance control system has been designed and installed into a non-rotating test rig. In order to harvest the benefit of tighter blade tip clearances, low-leakage seals are required for the actuated carrier segments of the seal shroud to prevent excessive leakage of compressor discharge (P3) cooling air. The test rig was designed and fabricated to facilitate the evaluation of these types of seals, identify seal leakage sources, and test other active clearance control system concepts. The objective of this paper is to present both experimental and analytical investigations into the nature of the face-seal to seal-carrier interface. Finite element analyses were used to examine face seal contact pressures and edge-loading under multiple loading conditions, varied E-seal positions and two new face seal heights. The analyses indicated that moving the E-seal inward radially and reducing face seal height would lead to more uniform contact conditions between the face seal and the carriers. Lab testing confirmed that moving the balance diameter inward radially caused a decrease in overall system leakage.
Energy Efficient Engine: Control system preliminary definition report
NASA Technical Reports Server (NTRS)
Howe, David C.
1986-01-01
The object of the Control Preliminary Definition Program was to define a preliminary control system concept as a part of the Energy Efficient Engine program. The program was limited to a conceptual definition of a full authority digital electronic control system. System requirements were determined and a control system was conceptually defined to these requirements. Areas requiring technological development were identified and a plan was established for implementing the identified technological features, including a control technology demonstration. A significant element of this program was a study of the potential benefits of closed-loop active clearance control, along with laboratory tests of candidate clearance sensor elements for a closed loop system.
Dimerization of glycoprotein Ibα is not sufficient to induce platelet clearance.
Liang, X; Syed, A K; Russell, S R; Ware, J; Li, R
2016-02-01
ESSENTIALS: Many anti-glycoprotein (GP)Ibα antibodies induce platelet clearance in a dimer-dependent manner. Characterization of monoclonal antibodies that bind the mechanosensitive domain (MSD) of GPIbα. An anti-MSD antibody binds two copies of GPIbα in platelets but does not induce platelet clearance. The prevailing clustering model of GPIbα signaling is incorrect or needs revision. The mechanism of platelet clearance is not clear. Many antibodies binding the membrane-distal ligand-binding domain of glycoprotein (GP)Ibα induce rapid clearance of platelets and acute thrombocytopenia, which requires the bifurcated antibody structure. It was thought that binding of these antibodies induced lateral dimerization or clustering of GPIbα in the plasma membrane, which leads to downstream signaling and platelet clearance. However, many antibodies targeting GPIbβ and GPIX, which are associated with GPIbα in the GPIb-IX complex, do not induce platelet clearance, which is in contradiction to the clustering model. To test whether dimerization or clustering of GPIbα is sufficient to transmit the signal that leads to platelet clearance. We have recently raised several mAbs targeting the mechanosensitive domain (MSD) of GPIbα. Binding of these anti-MSD antibodies was characterized with biochemical methods. Their ability to stimulate platelets and induce platelet clearance in mice was assessed. Infusion of anti-MSD antibodies does not cause thrombocytopenia in mice. These antibodies show no detectable effects on platelet activation and aggregation in vitro. Further biochemical investigation showed that the anti-MSD antibody 3D1 binds two copies of GPIbα on the platelet surface. Therefore, lateral dimerization of GPIbα induced by antibody binding is not sufficient to initiate GPIb-IX signaling and induce platelet clearance. Our results suggest that a factor other than or in addition to clustering of GPIbα is required to induce platelet clearance. © 2015 International Society on Thrombosis and Haemostasis.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-06
... titled, ``Company-Run Annual Stress Test Reporting Template and Documentation for Covered Institutions... review and clearance. Company-Run Annual Stress Test Reporting Template and Documentation for Covered... savings associations, to conduct annual stress tests \\2\\ and requires the primary financial regulatory...
Application of chromatic confocal displacement sensor in measurement of tip clearance
NASA Astrophysics Data System (ADS)
Bi, Chao; Li, Di; Fang, Jianguo; Zhang, Bin
2016-10-01
In the field of aeronautics, the tip clearance of rotor exerts a crucial influence on the performance of the aero engine. As defined as the radial distance between the top of the blade and the inner wall of the casing, the tip clearance of too large or small size will adversely affect the normal running of the engine. In order to realize accurate measurement of the tip clearance in a simple way, a non-contact measuring method by the chromatic confocal displacement sensor is proposed in the paper. The sensor possesses the advantages such as small volume, good signal-to-noise ratio, high accuracy and response frequency etc., which make it be widely used in engineering and industry. For testing the performance and potential application of the sensor, a simulation testing platform is established. In the platform, a simulation blisk is installed on the air bearing spindle and a chromatic confocal displacement sensor is fixed on the platform to measure the displacement variation of the blade tip, which can be used to characterize the variation of the tip clearance. In the simulation experiments, both of single and continuous measurement of the tip clearance of the 36 blades on the blisk is executed. As the results of experiments show, the chromatic confocal displacement sensor can meet the requirements of measuring task, in which both of high measuring efficiency and accuracy could be achieved. Therefore, the measuring method proposed in the paper can be utilized in the actual assembling sites of the aero engine.
NASA Technical Reports Server (NTRS)
Kratz, Jonathan L.; Chapman, Jeffryes W.; Guo, Ten-Huei
2017-01-01
The efficiency of aircraft gas turbine engines is sensitive to the distance between the tips of its turbine blades and its shroud, which serves as its containment structure. Maintaining tighter clearance between these components has been shown to increase turbine efficiency, increase fuel efficiency, and reduce the turbine inlet temperature, and this correlates to a longer time-on-wing for the engine. Therefore, there is a desire to maintain a tight clearance in the turbine, which requires fast response active clearance control. Fast response active tip clearance control will require an actuator to modify the physical or effective tip clearance in the turbine. This paper evaluates the requirements of a generic active turbine tip clearance actuator for a modern commercial aircraft engine using the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software that has previously been integrated with a dynamic tip clearance model. A parametric study was performed in an attempt to evaluate requirements for control actuators in terms of bandwidth, rate limits, saturation limits, and deadband. Constraints on the weight of the actuation system and some considerations as to the force which the actuator must be capable of exerting and maintaining are also investigated. From the results, the relevant range of the evaluated actuator parameters can be extracted. Some additional discussion is provided on the challenges posed by the tip clearance control problem and the implications for future small core aircraft engines.
Study of blade clearance effects on centrifugal pumps
NASA Technical Reports Server (NTRS)
Hoshide, R. K.; Nielson, C. E.
1972-01-01
A program of analysis, design, fabrication, and testing has been conducted to develop and experimentally verify analytical models to predict the effects of impeller blade clearance on centrifugal pumps. The effect of tip clearance on pump efficiency, and the relationship between the head coefficient and torque loss with tip clearance was established. Analysis were performed to determine the cost variation in design, manufacture, and test that would occur between unshrouded and shrouded impellers. An impeller, representative of typical rocket engine impellers, was modified by removing its front shroud to permit variation of its blade clearances. It was tested in water with special instrumentation to provide measurements of blade surface pressures during operation. Pump performance data were obtained from tests at various impeller tip clearances. Blade pressure data were obtained at the nominal tip clearance. Comparisons of predicted and measured data are given.
Smieszek, Timo; White, Peter J
2016-01-01
Mycoplasma genitalium is a potentially major cause of urethritis, cervicitis, pelvic inflammatory disease, infertility, and increased HIV risk. A better understanding of its natural history is crucial to informing control policy. Two extensive cohort studies (students in London, UK; Ugandan sex workers) suggest very different clearance rates; we aimed to understand the reasons and obtain improved estimates by making maximal use of the data from the studies. As M. genitalium is a sexually-transmitted infectious disease, we developed a model for time-to-event analysis that incorporates the processes of (re)infection and clearance, and fitted to data from the two cohort studies to estimate incidence and clearance rates under different scenarios of sexual partnership dynamics and study design (including sample handling and associated test sensitivity). In the London students, the estimated clearance rate is 0.80 p.a. (mean duration 15 months), with incidence 1.31%-3.93% p.a. Without adjusting for study design, corresponding estimates from the Ugandan data are 3.44 p.a. (mean duration 3.5 months) and 58% p.a. Apparent differences in clearance rates are probably mostly due to lower testing sensitivity in the Uganda study due to differences in sample handling, with 'true' clearance rates being similar, and adjusted incidence in Uganda being 28% p.a. Some differences are perhaps due to the sex workers having more-frequent antibiotic treatment, whilst reinfection within ongoing sexual partnerships might have caused some of the apparently-persistent infection in the London students. More information on partnership dynamics would inform more accurate estimates of natural-history parameters. Detailed studies in men are also required.
19 CFR 4.61 - Requirements for clearance.
Code of Federal Regulations, 2010 CFR
2010-04-01
... transported in-bond, or when they have unentered foreign merchandise aboard. For the purposes of the vessel clearance requirements, merchandise transported in-bond does not include bonded ship's stores or supplies. While American vessels transporting unentered foreign merchandise must fully comply with usual clearance...
Folmsbee, Martha; Lentine, Kerry Roche; Wright, Christine; Haake, Gerhard; Mcburnie, Leesa; Ashtekar, Dilip; Beck, Brian; Hutchison, Nick; Okhio-Seaman, Laura; Potts, Barbara; Pawar, Vinayak; Windsor, Helena
2014-01-01
Mycoplasma are bacteria that can penetrate 0.2 and 0.22 μm rated sterilizing-grade filters and even some 0.1 μm rated filters. Primary applications for mycoplasma filtration include large scale mammalian and bacterial cell culture media and serum filtration. The Parenteral Drug Association recognized the absence of standard industry test parameters for testing and classifying 0.1 μm rated filters for mycoplasma clearance and formed a task force to formulate consensus test parameters. The task force established some test parameters by common agreement, based upon general industry practices, without the need for additional testing. However, the culture medium and incubation conditions, for generating test mycoplasma cells, varied from filter company to filter company and was recognized as a serious gap by the task force. Standardization of the culture medium and incubation conditions required collaborative testing in both commercial filter company laboratories and in an Independent laboratory (Table I). The use of consensus test parameters will facilitate the ultimate cross-industry goal of standardization of 0.1 μm filter claims for mycoplasma clearance. However, it is still important to recognize filter performance will depend on the actual conditions of use. Therefore end users should consider, using a risk-based approach, whether process-specific evaluation of filter performance may be warranted for their application. Mycoplasma are small bacteria that have the ability to penetrate sterilizing-grade filters. Filtration of large-scale mammalian and bacterial cell culture media is an example of an industry process where effective filtration of mycoplasma is required. The Parenteral Drug Association recognized the absence of industry standard test parameters for evaluating mycoplasma clearance filters by filter manufacturers and formed a task force to formulate such a consensus among manufacturers. The use of standardized test parameters by filter manufacturers, including the preparation of the culture broth, will facilitate the end user's evaluation of the mycoplasma clearance claims provided by filter vendors. However, it is still important to recognize filter performance will depend on the actual conditions of use; therefore end users should consider, using a risk-based approach, whether process-specific evaluation of filter performance may be warranted for their application. © PDA, Inc. 2014.
19 CFR 4.61 - Requirements for clearance.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 1 2014-04-01 2014-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...
19 CFR 4.61 - Requirements for clearance.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 1 2013-04-01 2013-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...
19 CFR 4.61 - Requirements for clearance.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 1 2012-04-01 2012-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...
19 CFR 4.61 - Requirements for clearance.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 1 2011-04-01 2011-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...
Foong, Rachel E.; Harper, Alana J.; King, Louise; Turkovic, Lidija; Davis, Miriam; Clem, Charles C.; Davis, Stephanie D.; Ranganathan, Sarath; Hall, Graham L.
2018-01-01
The lung clearance index (LCI) from the multiple-breath washout (MBW) test is a promising surveillance tool for pre-school children with cystic fibrosis (CF). Current guidelines for MBW testing recommend that three acceptable trials are required. However, success rates to achieve these criteria are low in children aged <7 years and feasibility may improve with modified pre-school criteria that accepts tests with two acceptable trials. This study aimed to determine if relationships between LCI and clinical outcomes of CF lung disease differ when only two acceptable MBW trials are assessed. Healthy children and children with CF aged 3–6 years were recruited for MBW testing. Children with CF also underwent bronchoalveolar lavage fluid collection and a chest computed tomography scan. MBW feasibility increased from 46% to 75% when tests with two trials were deemed acceptable compared with tests where three acceptable trials were required. Relationships between MBW outcomes and markers of pulmonary inflammation, infection and structural lung disease were not different between tests with three acceptable trials compared with tests with two acceptable trials. This study indicates that pre-school MBW data from two acceptable trials may provide sufficient information on ventilation distribution if three acceptable trials are not possible. PMID:29707562
The Role of Radial Clearance on the Performance of Foil Air Bearings
NASA Technical Reports Server (NTRS)
Radil, Kevin; Howard, Samuel; Dykas, Brian
2002-01-01
Load capacity tests were conducted to determine how radial clearance variations affect the load capacity coefficient of foil air bearings. Two Generation III foil air bearings with the same design but possessing different initial radial clearances were tested at room temperature against an as-ground PS304 coated journal operating at 30,000 rpm. Increases in radial clearance were accomplished by reducing the journal's outside diameter via an in-place grinding system. From each load capacity test the bearing load capacity coefficient was calculated from the rule-of-thumb (ROT) model developed for foil air bearings. The test results indicate that, in terms of the load capacity coefficient, radial clearance has a direct impact on the performance of the foil air bearing. Each test bearing exhibited an optimum radial clearance that resulted in a maximum load capacity coefficient. Relative to this optimum value are two separate operating regimes that are governed by different modes of failure. Bearings operating with radial clearances less than the optimum exhibit load capacity coefficients that are a strong function of radial clearance and are prone to a thermal runaway failure mechanism and bearing seizure. Conversely, a bearing operating with a radial clearance twice the optimum suffered only a 20 percent decline in its maximum load capacity coefficient and did not experience any thermal management problems. However, it is unknown to what degree these changes in radial clearance had on other performance parameters, such as the stiffness and damping properties of the bearings.
Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... the body entirely by the kidneys. If kidney function is abnormal, creatinine level increases in the blood ...
14 CFR 103.23 - Flight visibility and cloud clearance requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...
14 CFR 103.23 - Flight visibility and cloud clearance requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...
14 CFR 103.23 - Flight visibility and cloud clearance requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...
14 CFR 103.23 - Flight visibility and cloud clearance requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...
14 CFR 103.23 - Flight visibility and cloud clearance requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...
Advanced turbine blade tip seal system
NASA Technical Reports Server (NTRS)
Zelahy, J. W.
1981-01-01
An advanced blade/shroud system designed to maintain close clearance between blade tips and turbine shrouds and at the same time, be resistant to environmental effects including high temperature oxidation, hot corrosion, and thermal cycling is described. Increased efficiency and increased blade life are attained by using the advanced blade tip seal system. Features of the system include improved clearance control when blade tips preferentially wear the shrouds and a superior single crystal superalloy tip. The tip design, joint location, characterization of the single crystal tip alloy, the abrasive tip treatment, and the component and engine test are among the factors addressed. Results of wear testing, quality control plans, and the total manufacturing cycle required to fully process the blades are also discussed.
30 CFR 18.24 - Electrical clearances.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor surfaces, or between uninsulated conductor surfaces and grounded metal surfaces, within the enclosure shall...
30 CFR 18.24 - Electrical clearances.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor surfaces, or between uninsulated conductor surfaces and grounded metal surfaces, within the enclosure shall...
30 CFR 18.24 - Electrical clearances.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor...
30 CFR 18.24 - Electrical clearances.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor...
30 CFR 18.24 - Electrical clearances.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor...
14 CFR 105.17 - Flight visibility and clearance from cloud requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...
14 CFR 105.17 - Flight visibility and clearance from cloud requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...
14 CFR 105.17 - Flight visibility and clearance from cloud requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...
14 CFR 105.17 - Flight visibility and clearance from cloud requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...
14 CFR 105.17 - Flight visibility and clearance from cloud requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Flight visibility and clearance from cloud... Flight visibility and clearance from cloud requirements. No person may conduct a parachute operation, and...— (a) Into or through a cloud, or (b) When the flight visibility or the distance from any cloud is less...
Monsanto may bypass NIH in microbe test.
Sun, Marjorie
1985-01-11
The Monsanto Company is planning to ask the Environmental Protection Agency for clearance to field test a genetically engineered microbial pesticide, bypassing the traditional approval process of the National Institutes of Health. Although only federally funded institutions are required to obtain NIH approval for genetic engineering tests, Monsanto is the first company to bypass the NIH regulatory process, which has become mired in a lawsuit brought by Jeremy Rifkin.
76 FR 55726 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-08
... for clearance by OMB as required under the PRA: Title: Occupational Noise Exposure for Railroad... to ensure that railroads covered by this rule establish and implement--by specified dates--noise monitoring, hearing conservation, and audiometric testing programs, as well as hearing conservation training...
Hsieh, Chung-Bao; Chen, Chung-Jueng; Chen, Teng-Wei; Yu, Jyh-Cherng; Shen, Kuo-Liang; Chang, Tzu-Ming; Liu, Yao-Chi
2004-01-01
AIM: To investigate whether the non-invasive real-time Indocynine green (ICG) clearance is a sensitive index of liver viability in patients before, during, and after liver transplantation. METHODS: Thirteen patients were studied, two before, three during, and eight following liver transplantation, with two patients suffering acute rejection. The conventional invasive ICG clearance test and ICG pulse spectrophotometry non-invasive real-time ICG clearance test were performed simultaneously. Using linear regression analysis we tested the correlation between these two methods. The transplantation condition of these patients and serum total bilirubin (T. Bil), alanine aminotransferase (ALT), and platelet count were also evaluated. RESULTS: The correlation between these two methods was excellent (r2 = 0.977). CONCLUSION: ICG pulse spectrophotometry clearance is a quick, non-invasive, and reliable liver function test in transplantation patients. PMID:15285026
Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts
NASA Technical Reports Server (NTRS)
Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.
2003-01-01
Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.
NASA Technical Reports Server (NTRS)
Gaffin, W. O.
1979-01-01
The JT9D-70/59 high pressure turbine active clearance control system was modified to provide reduction of blade tip clearance when the system is activated during cruise operation. The modification increased the flow capacity and air impingement effectiveness of the cooling air manifold to augment turbine case shrinkage capability, and increased responsiveness of the airseal clearance to case shrinkage. The simulated altitude engine testing indicated a significant improvement in specific fuel consumption with the modified system. A 1000 cycle engine endurance test showed no unusual wear or performance deterioration effects on the engine or the clearance control system. Rig tests indicated that the air impingement and seal support configurations used in the engine tests are near optimum.
Code of Federal Regulations, 2014 CFR
2014-01-01
... authorizations or clearances will be defined. (1) “Q” access authorizations or clearances are based upon full... quantities as required in the performance of duties. (2) “Q(X)” access authorizations or clearances are based...” access authorizations or clearances are based upon National Agency Checks and Inquiries (NACI) for...
Code of Federal Regulations, 2012 CFR
2012-01-01
... authorizations or clearances will be defined. (1) “Q” access authorizations or clearances are based upon full... quantities as required in the performance of duties. (2) “Q(X)” access authorizations or clearances are based...” access authorizations or clearances are based upon National Agency Checks and Inquiries (NACI) for...
Adapting viral safety assurance strategies to continuous processing of biological products.
Johnson, Sarah A; Brown, Matthew R; Lute, Scott C; Brorson, Kurt A
2017-01-01
There has been a recent drive in commercial large-scale production of biotechnology products to convert current batch mode processing to continuous processing manufacturing. There have been reports of model systems capable of adapting and linking upstream and downstream technologies into a continuous manufacturing pipeline. However, in many of these proposed continuous processing model systems, viral safety has not been comprehensively addressed. Viral safety and detection is a highly important and often expensive regulatory requirement for any new biological product. To ensure success in the adaption of continuous processing to large-scale production, there is a need to consider the development of approaches that allow for seamless incorporation of viral testing and clearance/inactivation methods. In this review, we outline potential strategies to apply current viral testing and clearance/inactivation technologies to continuous processing, as well as modifications of existing unit operations to ensure the successful integration of viral clearance into the continuous processing of biological products. Biotechnol. Bioeng. 2017;114: 21-32. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Jacob, G.; Shannon, J. R.; Costa, F.; Furlan, R.; Biaggioni, I.; Mosqueda-Garcia, R.; Robertson, R. M.; Robertson, D.
1999-01-01
BACKGROUND: Chronic orthostatic intolerance (OI) is characterized by symptoms of inadequate cerebral perfusion with standing, in the absence of significant orthostatic hypotension. A heart rate increase of >/=30 bpm is typical. Possible underlying pathophysiologies include hypovolemia, partial dysautonomia, or a primary hyperadrenergic state. We tested the hypothesis that patients with OI have functional abnormalities in autonomic neurons regulating cardiovascular responses. METHODS AND RESULTS: Thirteen patients with chronic OI and 10 control subjects underwent a battery of autonomic tests. Systemic norepinephrine (NE) kinetics were determined with the patients supine and standing before and after tyramine administration. In addition, baroreflex sensitivity, hemodynamic responses to bolus injections of adrenergic agonists, and intrinsic heart rate were determined. Resting supine NE spillover and clearance were similar in both groups. With standing, patients had a greater decrease in NE clearance than control subjects (55+/-5% versus 30+/-7%, P<0.02). After tyramine, NE spillover did not change significantly in patients but increased 50+/-10% in control subjects (P<0.001). The dose of isoproterenol required to increase heart rate 25 bpm was lower in patients than in control subjects (0.5+/-0.05 versus 1.0+/-0.1 microg, P<0.005), and the dose of phenylephrine required to increase systolic blood pressure 25 mm Hg was lower in patients than control subjects (105+/-11 versus 210+/-12 microg, P<0.001). Baroreflex sensitivity was lower in patients (12+/-1 versus 18+/-2 ms/mm Hg, P<0.02), but the intrinsic heart rate was similar in both groups. CONCLUSIONS: The decreased NE clearance with standing, resistance to the NE-releasing effect of tyramine, and increased sensitivity to adrenergic agonists demonstrate dramatically disordered sympathetic cardiovascular regulation in patients with chronic OI.
29 CFR 9.12 - Contractor requirements and prerogatives.
Code of Federal Regulations, 2014 CFR
2014-07-01
... utilize employment screening processes (i.e., drug tests, background checks, security clearance checks, and similar pre-employment screening mechanisms) only when such processes are provided for by the... example, if the contractor holds a meeting for a group of employees on the predecessor contract in order...
29 CFR 9.12 - Contractor requirements and prerogatives.
Code of Federal Regulations, 2012 CFR
2012-07-01
... utilize employment screening processes (i.e., drug tests, background checks, security clearance checks, and similar pre-employment screening mechanisms) only when such processes are provided for by the... example, if the contractor holds a meeting for a group of employees on the predecessor contract in order...
29 CFR 9.12 - Contractor requirements and prerogatives.
Code of Federal Regulations, 2013 CFR
2013-07-01
... utilize employment screening processes (i.e., drug tests, background checks, security clearance checks, and similar pre-employment screening mechanisms) only when such processes are provided for by the... example, if the contractor holds a meeting for a group of employees on the predecessor contract in order...
76 FR 34761 - Classified National Security Information
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-14
... Commission is a micro agency of 14 full time permanent employees. Three employees have current Secret clearances and one staff has a Top Secret clearance. These employees require clearances because they attend...
Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance
NASA Technical Reports Server (NTRS)
Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.
2002-01-01
This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.
Predicting Operator Execution Times Using CogTool
NASA Technical Reports Server (NTRS)
Santiago-Espada, Yamira; Latorella, Kara A.
2013-01-01
Researchers and developers of NextGen systems can use predictive human performance modeling tools as an initial approach to obtain skilled user performance times analytically, before system testing with users. This paper describes the CogTool models for a two pilot crew executing two different types of a datalink clearance acceptance tasks, and on two different simulation platforms. The CogTool time estimates for accepting and executing Required Time of Arrival and Interval Management clearances were compared to empirical data observed in video tapes and registered in simulation files. Results indicate no statistically significant difference between empirical data and the CogTool predictions. A population comparison test found no significant differences between the CogTool estimates and the empirical execution times for any of the four test conditions. We discuss modeling caveats and considerations for applying CogTool to crew performance modeling in advanced cockpit environments.
Novel sensors to enable closed-loop active clearance control in gas turbine engines
NASA Astrophysics Data System (ADS)
Geisheimer, Jonathan; Holst, Tom
2014-06-01
Active clearance control within the turbine section of gas turbine engines presents and opportunity within aerospace and industrial applications to improve operating efficiencies and the life of downstream components. Open loop clearance control is currently employed during the development of all new large core aerospace engines; however, the ability to measure the gap between the blades and the case and close down the clearance further presents as opportunity to gain even greater efficiencies. The turbine area is one of the harshest environments for long term placement of a sensor in addition to the extreme accuracy requirements required to enable closed loop clearance control. This paper gives an overview of the challenges of clearance measurements within the turbine as well as discusses the latest developments of a microwave sensor designed for this application.
NASA Astrophysics Data System (ADS)
Hai-yang, Zhao; Min-qiang, Xu; Jin-dong, Wang; Yong-bo, Li
2015-05-01
In order to improve the accuracy of dynamics response simulation for mechanism with joint clearance, a parameter optimization method for planar joint clearance contact force model was presented in this paper, and the optimized parameters were applied to the dynamics response simulation for mechanism with oversized joint clearance fault. By studying the effect of increased clearance on the parameters of joint clearance contact force model, the relation of model parameters between different clearances was concluded. Then the dynamic equation of a two-stage reciprocating compressor with four joint clearances was developed using Lagrange method, and a multi-body dynamic model built in ADAMS software was used to solve this equation. To obtain a simulated dynamic response much closer to that of experimental tests, the parameters of joint clearance model, instead of using the designed values, were optimized by genetic algorithms approach. Finally, the optimized parameters were applied to simulate the dynamics response of model with oversized joint clearance fault according to the concluded parameter relation. The dynamics response of experimental test verified the effectiveness of this application.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-14
... Collection Activities: Proposed Collection; Comment Request, Generic Clearance for Cognitive, Pilot and Field... information collection clearance that will allow BJS to conduct a variety of cognitive, pilot, and field test... new or modified data collection, BJS will engage in cognitive, pilot and field test activities to...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-20
... Activities; Proposed Collection; Comment Request: Generic Clearance for Cognitive, Pilot and Field Studies...) Title of the Form/Collection: BJS Generic Clearance for Cognitive, Pilot, and Field Test Studies. (3... respondents will be involved in exploratory, field test, pilot, cognitive, and focus group work conducted...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-14
... Collection Activities: Proposed Collection; Comment Request; Generic Clearance for Cognitive, Pilot and Field... information collection clearance that will allow BJS to conduct a variety of cognitive, pilot, and field test... new or modified data collection, BJS will engage in cognitive, pilot and field test activities to...
Qualitative Maintenance Experience Handbook. P-3C/S-3A Supplement.
1977-06-15
axle which automatically assists in disc alignment, a positive feature, in easing maintenance and preventing casual damage. Brake assemblies should...Reverse Of Removal Use brake tool to align brake discs . After Installation Actions: _ Bleed _ Rig _ Adjust X Service Lubricate - Boresight. _ Other...Hydraulic I Access Required: Test Equipment Required: Actions: 1. Check clearance of discs after brakes are put on. 2. Apply brakes . 8 ANALYST’S COMMENTS
Ståhl, K; Lindberg, A; Rivera, H; Ortiz, C; Moreno-López, J
2008-03-17
In this cross-sectional study, a stratified two-stage random sampling procedure was employed to select 221 dairy herds for bulk tank milk (BTM) sampling, and a subset of 55 dairy herds for individual blood sampling of a number of young animals (spot test), to predict presence or absence of current BVDV infection, and for data collection. The prediction was based on the high probability of seropositivity in groups of animals where PI animals are present because of the efficient spread of virus from PI animals to the surrounding group. BTM samples were collected in August 2003 (n=192) and February 2004 (n=195), and the 55 herds selected for spot testing and data collection were visited in December 2003. All samples were tested for presence of BVDV specific antibodies using a commercial indirect ELISA (SVANOVA Biotech AB, Uppsala, Sweden). The results demonstrated a very high level of exposure to BVDV in the region, and the proportion of herds with high antibody levels in the BTM was above 95% on both occasions. Despite this, almost two thirds of the herds had spot test results indicating absence of current infection, suggesting a high probability of self-clearance. A logistic regression model with the results from the spot tests as dependent variable was used to investigate possible herd and management factors associated with self-clearance, and suggested that this may occur regardless of herd size. Even though it is well established that the process of identification and elimination of PI animals is required within a systematic BVDV eradication programme, the present study strongly suggests that many herds may be cleared without intervention even in regions with high cattle density and high BVDV prevalence. Consequently, in any BVDV infected population (regardless of the herd-level BVDV seroprevalence), and at any given point of time, a large proportion of the herds will be free from infection due to self-clearance. Self-clearance is therefore a process that works in favour of any effort to control BVDV, which should be taken into account when planning and assessing the cost-effectiveness of a systematic control programme.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-14
... Collection Activities: Proposed Collection; Comment Request; Generic Clearance for Cognitive, Pilot and Field... information collection clearance that will allow BJS to conduct a variety of cognitive, pilot, and field test... each new or modified data collection, BJS will engage in cognitive, pilot and field test activities to...
19 CFR 122.157 - Documents required for clearance.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Documents required for clearance. 122.157 Section 122.157 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Flights to and From Cuba § 122.157 Documents required for...
7 CFR 1927.54 - Requirements for closing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 12 2010-01-01 2010-01-01 false Requirements for closing agents. 1927.54 Section 1927... PROGRAM REGULATIONS TITLE CLEARANCE AND LOAN CLOSING Real Estate Title Clearance and Loan Closing § 1927.54 Requirements for closing agents. (a) Form of title certification. State Offices are directed to...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Negrete, Oscar A.; Branda, Catherine; Hardesty, Jasper O. E.
In the response to and recovery from a critical homeland security event involving deliberate or accidental release of biological agents, initial decontamination efforts are necessarily followed by tests for the presence of residual live virus or bacteria. Such 'clearance sampling' should be rapid and accurate, to inform decision makers as they take appropriate action to ensure the safety of the public and of operational personnel. However, the current protocol for clearance sampling is extremely time-intensive and costly, and requires significant amounts of laboratory space and capacity. Detection of residual live virus is particularly problematic and time-consuming, as it requires evaluationmore » of replication potential within a eukaryotic host such as chicken embryos. The intention of this project was to develop a new method for clearance sampling, by leveraging Sandia's expertise in the biological and material sciences in order to create a C. elegans-based foam that could be applied directly to the entire contaminated area for quick and accurate detection of any and all residual live virus by means of a fluorescent signal. Such a novel technology for rapid, on-site detection of live virus would greatly interest the DHS, DoD, and EPA, and hold broad commercial potential, especially with regard to the transportation industry.« less
78 FR 21162 - Notice of Intent to Establish an Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-09
... Programs. NCSES, under generic clearance (OMB 3145-0174), has conducted a methodological study to test a.... Estimate of Burden: In the methodological study, HAs required 1 hour on average to complete these tasks...,206 hours. Most ECs were able to complete this task in less than 30 minutes in the methodological...
78 FR 49323 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-13
... Information Collection Request (ICR) abstracted below will be forwarded to the Office of Management and Budget... for clearance by OMB as required by the PRA. Title: Electronic Device Distraction: Test of Peer to... consoles, personal computers, etc.) is known to be a factor in some accidents and suspected of being the...
Rocket Fuel R and D at AFRL: Recent Activities and Future Direction
2017-04-12
Clearance Number 17163 Rocket Cycles and Environments SpaceX Merlin 1D 190 klbf Russian RD-180 860 klbf Gas Generator Cycle Ox-Rich Staged Combustion...affordability & reusability • Modeling & Simulation • Key to development • Requires accurate models “CFD simulations… shorten the test-fail-fix loop” SpaceX
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-12
...The Department of Transportation (DOT) invites public comments about our intention to request the Office of Management and Budget (OMB) approval to renew an information collection. The collection involves Transportation Drug and Alcohol Testing. The information to be collected will be used to document tests conducted and actions taken to ensure safety in the workplace and/or is necessary because under the Omnibus Transportation Employee Testing Act of 1991, DOT is required to implement a drug and alcohol testing program in various transportation- related industries. DOT is required to publish this notice in the Federal Register in accordance with the Paperwork Reduction Act of 1995, Public Law 104-13.
32 CFR 154.77 - Reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... took the action, using the enclosed format: (1) Number of Top Secret, Secret, and Confidential clearances issued; (2) Number of Top Secret, Secret, and Confidential clearances denied; (3) Number of Top...) Total number of personnel holding a clearance for Top Secret, Secret, Confidential and Sensitive...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-16
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare and Medicaid Services [Document Identifier: CMS-10371] Emergency Clearance: Public Information Collection Requirements Submitted to the Office of Management and Budget (OMB) AGENCY: Center for Medicare and Medicaid Services, HHS. In compliance with the requirement of section 3506(c)(2)...
Further Characterization of an Active Clearance Control Concept
NASA Technical Reports Server (NTRS)
Taylor, Shawn C.; Steinetz, Bruce M.; Oswald, Jay J.
2007-01-01
A new test chamber and precision hydraulic actuation system were incorporated into an active clearance control (ACC) test rig at NASA Glenn Research Center. Using the improved system, a fast-acting, mechanically-actuated, ACC concept was evaluated at engine simulated temperatures and pressure differentials up to 1140 F and 120 psig, on the basis of secondary seal leakage and kinematic controllability. During testing, the ACC concept tracked a simulated flight clearance transient profile at 1140 F, 120 psig, with a maximum error of only 0.0012 in. Comparison of average dynamic leakage of the system with average static leakage did not show significant differences between the two operating conditions. Calculated effective clearance values for the rig were approximately 0.0002 in. at 120 psig, well below the industry specified effective clearance threshold of 0.001 in.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-10
... precision requirements or power calculations that justify the proposed sample size, the expected response...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...
19 CFR 122.77 - Clearance certificate.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Clearance certificate. 122.77 Section 122.77 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic...
Non-Invasive Assessment of Liver Function
Helmke, Steve; Colmenero, Jordi; Everson, Gregory T.
2015-01-01
Purpose of review It is our opinion that there is an unmet need in Hepatology for a minimally- or noninvasive test of liver function and physiology. Quantitative liver function tests (QLFTs) define the severity and prognosis of liver disease by measuring the clearance of substrates whose uptake or metabolism is dependent upon liver perfusion or hepatocyte function. Substrates with high affinity hepatic transporters exhibit high “first-pass” hepatic extraction and their clearance measures hepatic perfusion. In contrast, substrates metabolized by the liver have low first-pass extraction and their clearance measures specific drug metabolizing pathways. Recent Findings We highlight one QLFT, the dual cholate test, and introduce the concept of a disease severity index (DSI) linked to clinical outcome that quantifies the simultaneous processes of hepatocyte uptake, clearance from the systemic circulation, clearance from the portal circulation, and portal-systemic shunting. Summary It is our opinion that dual cholate is a relevant test for defining disease severity, monitoring the natural course of disease progression, and quantifying the response to therapy. PMID:25714706
Labyrinth Seal Flutter Analysis and Test Validation in Support of Robust Rocket Engine Design
NASA Technical Reports Server (NTRS)
El-Aini, Yehia; Park, John; Frady, Greg; Nesman, Tom
2010-01-01
High energy-density turbomachines, like the SSME turbopumps, utilize labyrinth seals, also referred to as knife-edge seals, to control leakage flow. The pressure drop for such seals is order of magnitude higher than comparable jet engine seals. This is aggravated by the requirement of tight clearances resulting in possible unfavorable fluid-structure interaction of the seal system (seal flutter). To demonstrate these characteristics, a benchmark case of a High Pressure Oxygen Turbopump (HPOTP) outlet Labyrinth seal was studied in detail. First, an analytical assessment of the seal stability was conducted using a Pratt & Whitney legacy seal flutter code. Sensitivity parameters including pressure drop, rotor-to-stator running clearances and cavity volumes were examined and modeling strategies established. Second, a concurrent experimental investigation was undertaken to validate the stability of the seal at the equivalent operating conditions of the pump. Actual pump hardware was used to construct the test rig, also referred to as the (Flutter Rig). The flutter rig did not include rotational effects or temperature. However, the use of Hydrogen gas at high inlet pressure provided good representation of the critical parameters affecting flutter especially the speed of sound. The flutter code predictions showed consistent trends in good agreement with the experimental data. The rig test program produced a stability threshold empirical parameter that separated operation with and without flutter. This empirical parameter was used to establish the seal build clearances to avoid flutter while providing the required cooling flow metering. The calibrated flutter code along with the empirical flutter parameter was used to redesign the baseline seal resulting in a flutter-free robust configuration. Provisions for incorporation of mechanical damping devices were introduced in the redesigned seal to ensure added robustness
NASA Technical Reports Server (NTRS)
Poppel, G. L.; Marple, D. T. F.; Kingsley, J. D.
1981-01-01
Analyses and the design, fabrication, and testing of an optical tip clearance sensor with intended application in aircraft propulsion control systems are reported. The design of a sensor test rig, evaluation of optical sensor components at elevated temperatures, sensor design principles, sensor test results at room temperature, and estimations of sensor accuracy at temperatures of an aircraft engine environment are discussed. Room temperature testing indicated possible measurement accuracies of less than 12.7 microns (0.5 mils). Ways to improve performance at engine operating temperatures are recommended. The potential of this tip clearance sensor is assessed.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-15
... precision requirements or power calculations that justify the proposed sample size, the expected response...; Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-31
... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-03
... precision requirements or power calculations that justify the proposed sample size, the expected response... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-21
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare and Medicaid Services [Document Identifier: CMS-10496 Emergency Clearance: Public Information Collection Requirements Submitted to the Office of Management and Budget (OMB) AGENCY: Center for Medicare and Medicaid Services. In compliance with the requirement of section 3506(c)(2)(A) of...
JT9D performance deterioration results from a simulated aerodynamic load test
NASA Technical Reports Server (NTRS)
Stakolich, E. G.; Stromberg, W. J.
1981-01-01
The results of testing to identify the effects of simulated aerodynamic flight loads on JT9D engine performance are presented. The test results were also used to refine previous analytical studies on the impact of aerodynamic flight loads on performance losses. To accomplish these objectives, a JT9D-7AH engine was assembled with average production clearances and new seals as well as extensive instrumentation to monitor engine performance, case temperatures, and blade tip clearance changes. A special loading device was designed and constructed to permit application of known moments and shear forces to the engine by the use of cables placed around the flight inlet. The test was conducted in the Pratt & Whitney Aircraft X-Ray Test Facility to permit the use of X-ray techniques in conjunction with laser blade tip proximity probes to monitor important engine clearance changes. Upon completion of the test program, the test engine was disassembled, and the condition of gas path parts and final clearances were documented. The test results indicate that the engine lost 1.1 percent in thrust specific fuel consumption (TSFC), as measured under sea level static conditions, due to increased operating clearances caused by simulated flight loads. This compares with 0.9 percent predicted by the analytical model and previous study efforts.
48 CFR 801.602-81 - Documents required for business clearance reviews.
Code of Federal Regulations, 2010 CFR
2010-10-01
... business clearance reviews. 801.602-81 Section 801.602-81 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS GENERAL DEPARTMENT OF VETERANS AFFAIRS ACQUISITION REGULATION SYSTEM Career... reviews. When a bid or offer, proposed contract modification, or proposed lease requires a business...
18 CFR 3a.41 - Access requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... level of such clearance (Top Secret, Secret, Confidential). The Personnel Security Officer will maintain.... Additionally, when a staff member no longer needs access to a particular security classification category, the security clearance will be adjusted to the classification category required. In both cases, this action...
Haegele, Stefanie; Reiter, Silvia; Wanek, David; Offensperger, Florian; Pereyra, David; Stremitzer, Stefan; Fleischmann, Edith; Brostjan, Christine; Gruenberger, Thomas; Starlinger, Patrick
2016-01-01
Background Postoperative liver dysfunction may lead to morbidity and mortality after liver resection. Preoperative liver function assessment is critical to identify preexisting liver dysfunction in patients prior to resection. The aim of this study was to evaluate the predictive potential of perioperative indocyanine green (ICG)-clearance testing to prevent postoperative liver dysfunction and morbidity using standardized outcome parameters in a routine Western-clinical-setting. Study Design 137 patients undergoing partial hepatectomy between 2011 and 2013, at the general hospital of Vienna, were included. ICG-clearance was recorded one day prior to surgery as well as on the first and fifth postoperative day. Postoperative liver dysfunction was defined according to the International Study Group of Liver Surgery and evaluation of morbidity was based on the Dindo-Clavien classification. Statistical analyses were based on non-parametric tests. Results Preoperative reduced ICG—plasma disappearance rate (PDR) as well as increased ICG—retention rate at 15 min (R15) were able to significantly predict postoperative liver dysfunction (Area under the curve = PDR: 0.716, P = 0.018; R15: 0.719, P = 0.016). Furthermore, PDR <17%/min. or R15 >8%, were able to accurately predict postoperative complications prior to surgery. In addition to this, ICG-clearance on postoperative day 1 comparably predicted postoperative liver dysfunction (Area under the curve = PDR: 0.895; R15: 0.893; both P <0.001), specifically, PDR <10%/min or R15 >20% on postoperative day 1 predicted poor postoperative outcome. Conclusion PDR and R15 may represent useful parameters to distinguish preoperative high and low risk patients in a Western collective as well as on postoperative day 1, to identify patients who require closer monitoring for potential complications. PMID:27812143
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-05
... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Activities; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-09
... precision requirements or power calculations that justify the proposed sample size, the expected response... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-18
... clustering), the precision requirements or power calculations that justify the proposed sample size, the...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-09
... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-14
... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...
48 CFR 832.502-2 - Contract finance office clearance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress Payments Based on Costs 832.502-2 Contract finance office clearance. Contracting...
48 CFR 32.502-2 - Contract finance office clearance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress Payments Based on Costs 32.502-2 Contract finance office clearance. The contracting...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... Identifier: CMS-10510] Emergency Clearance: Public Information Collection Requirements Submitted to the Office of Management and Budget (OMB); Correction AGENCY: Centers for Medicare & Medicaid Services (CMS..., Federal Register notice (document identifier: CMS-10510) entitled ``Basic Health Program Report for Health...
Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Woike, Mark R.; Roeder, James W.; Hughes, Christopher E.; Bencic, Timothy J.
2009-01-01
The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high-temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short-range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a benchtop calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.
Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Woike, Mark R.; Roeder, James W.; Hughes, Christopher E.; Bencic, Timothy J.
2009-01-01
The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a bench top calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.
16 CFR Figures 6 and 7 to Part 1512 - Toe Clearance and Chain Guard Requirements
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Toe Clearance and Chain Guard Requirements 6 Figures 6 and 7 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BICYCLES Pt. 1512, Figs. 6 and 7 Figures 6 and 7 to Part 1512—Toe...
16 CFR Figures 6 and 7 to Part 1512 - Toe Clearance and Chain Guard Requirements
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Toe Clearance and Chain Guard Requirements 6 Figures 6 and 7 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BICYCLES Pt. 1512, Figs. 6 and 7 Figures 6 and 7 to Part 1512—Toe...
Shock and vibration tests of uranium mononitride fuel pellets for a space power nuclear reactor
NASA Technical Reports Server (NTRS)
Adams, D. W.
1972-01-01
Shock and vibration tests were conducted on cylindrically shaped, depleted, uranium mononitride (UN) fuel pellets. The structural capabilities of the pellets were determined under exposure to shock and vibration loading which a nuclear reactor may encounter during launching into space. Various combinations of diametral and axial clearances between the pellets and their enclosing structures were tested. The results of these tests indicate that for present fabrication of UN pellets, a diametral clearance of 0.254 millimeter and an axial clearance of 0.025 millimeter are tolerable when subjected to launch-induced loads.
Anthropometry and Standards for Wheeled Mobility: An International Comparison
ERIC Educational Resources Information Center
Steinfeld, Edward; Maisel, Jordana; Feathers, David; D'Souza, Clive
2010-01-01
Space requirements for accommodating wheeled mobility devices and their users in the built environment are key components of standards for accessible design. These requirements typically include dimensions for clear floor areas, maneuvering clearances, seat and knee clearance heights, as well as some reference dimensions on wheeled mobility device…
Rengasamy, Samy; Sbarra, Deborah; Nwoko, Julian; Shaffer, Ronald
2015-01-01
Background Surgical N95 filtering facepiece respirators (FFRs), certified by the National Institute for Occupational Safety and Health (NIOSH) as a respirator and cleared by the Food and Drug Administration (FDA) as a surgical mask, are often used to protect from the inhalation of infectious aerosols and from splashes/sprays of body fluids in health care facilities. A shortage of respirators can be expected during a pandemic. The availability of surgical N95 FFRs can potentially be increased by incorporating FDA clearance requirements in the NIOSH respirator approval process. Methods Fluid resistance of NIOSH-approved N95 FFRs, and FDA-cleared surgical N95 FFRs and surgical masks was tested using the ASTM F1862 method at 450 and 635 cm/sec velocities and compared with the results from a third-party independent laboratory. Blood penetration through different layers of filter media of masks were also analyzed visually. Results Four N95 FFR models showed no test failures at both velocities. The penetration results obtained in the NIOSH laboratory were comparable to those from the third-party independent laboratory. The number of respirator samples failing the test increased with increasing test velocity. Conclusions The results indicate that several NIOSH-approved N95 FFR models would likely pass FD clearance requirements for resistance to synthetic blood penetration. PMID:26231551
20 CFR 653.501 - Requirements for accepting and processing clearance orders.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., DEPARTMENT OF LABOR SERVICES OF THE EMPLOYMENT SERVICE SYSTEM Agricultural Clearance Order Activity § 653.501... function of the job service as a no-fee labor exchange, that is, as a forum for bringing together employers... referred through the clearance system shall be notified to contact a local job service office, preferably...
20 CFR 653.501 - Requirements for accepting and processing clearance orders.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., DEPARTMENT OF LABOR SERVICES OF THE EMPLOYMENT SERVICE SYSTEM Agricultural Clearance Order Activity § 653.501... function of the job service as a no-fee labor exchange, that is, as a forum for bringing together employers... referred through the clearance system shall be notified to contact a local job service office, preferably...
48 CFR 1432.502-2 - Contract finance office clearance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress Payments Based on Costs 1432.502-2 Contract finance office clearance. The CO shall...
31 CFR 205.20 - What is a clearance pattern?
Code of Federal Regulations, 2010 CFR
2010-07-01
..., unless additional data is required to accurately represent the flow of Federal funds. (e) If a State uses... FEDERAL-STATE FUNDS TRANSFERS Rules Applicable to Federal Assistance Programs Included in a Treasury-State Agreement § 205.20 What is a clearance pattern? States use clearance patterns to project when funds are paid...
Abbas, Chiara; Singer, Florian; Yammine, Sophie; Casaulta, Carmen; Latzin, Philipp
2013-12-01
We studied the ability of 4 single-breath gas washout (SBW) tests to measure immediate effects of airway clearance in children with CF. 25 children aged 4-16 years with CF performed pulmonary function tests to assess short-term variability at baseline and response to routine airway clearance. Tidal helium and sulfur hexafluoride (double-tracer gas: DTG) SBW, tidal capnography, tidal and vital capacity nitrogen (N2) SBW and spirometry were applied. We analyzed the gasses' phase III slope (SnIII--normalized for tidal volume) and FEV1 from spirometry. SnIII from tidal DTG-SBW, SnIII from vital capacity N2-SBW, and FEV1 improved significantly after airway clearance. From these tests, individual change of SnIII from tidal DTG-SBW and FEV1 exceeded short-term variability in 10 and 6 children. With the tidal DTG-SBW, an easy and promising test for peripheral gas mixing efficiency, immediate pulmonary function response to airway clearance can be assessed in CF children. Copyright © 2013 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Acute Mucociliary Clearance Response to Aerobic Exercise in Smokers.
Ramos, Ercy M C; Vanderlei, Luiz Carlos M; Ito, Juliana T; Lima, Fabiano F; Rodrigues, Fernanda M M; Manzano, Beatriz M; Fernandes, Rômulo A; Cecílio, Michel J; Toledo-Arruda, Alessandra C; Ramos, Dionei
2015-11-01
Mucociliary clearance is the main defense mechanism of the respiratory system, and it is influenced by several stimuli, including aerobic exercise and cigarette smoking. We evaluated the acute response of mucociliary clearance to aerobic exercise in smokers and nonsmokers compared with that found after acute smoking and smoking combined with exercise. Also, we investigated whether there was a correlation between mucociliary clearance and the autonomic nervous system under these conditions. Twenty-one smokers were evaluated for mucociliary clearance by saccharin transit time (STT), and the response of the autonomic nervous system was evaluated by heart rate variability after aerobic exercise, after exercise followed by smoking, after acute smoking, and after rest. For comparison, 17 nonsmokers were also assessed during exercise. Repeated-measures analysis of variance with the Tukey test or the Friedman test followed by the Dunn test was used to evaluate the STT, autonomic response, and other variables to exercise and/or smoking in smokers. A paired t test or Wilcoxon test was used to analyze responses to exercise in nonsmokers. Correlations were evaluated using Pearson or Spearman coefficients. The STT was reduced after exercise in both groups, with similar responses between them. Other stimuli also reduced the STT. The STT showed a negative correlation with sympathetic activity in smokers and a positive correlation with the parasympathetic system in nonsmokers. Although impaired in smokers, mucociliary clearance responded to the stimulus of exercise, as demonstrated by similar STTs compared with nonsmokers. This response was correlated with the autonomic nervous system in both groups. In smokers, mucociliary clearance also responded to the stimuli of smoking and exercise followed by smoking. Copyright © 2015 by Daedalus Enterprises.
Energy Efficient Engine: High-pressure compressor test hardware detailed design report
NASA Technical Reports Server (NTRS)
Howe, David C.; Marchant, R. D.
1988-01-01
The objective of the NASA Energy Efficient Engine program is to identify and verify the technology required to achieve significant reductions in fuel consumption and operating cost for future commercial gas turbine engines. The design and analysis is documented of the high pressure compressor which was tested as part of the Pratt and Whitney effort under the Energy Efficient Engine program. This compressor was designed to produce a 14:1 pressure ratio in ten stages with an adiabatic efficiency of 88.2 percent in the flight propulsion system. The corresponding expected efficiency for the compressor component test rig is 86.5 percent. Other performance goals are a surge margin of 20 percent, a corrected flow rate of 35.2 kg/sec (77.5 lb/sec), and a life of 20,000 missions and 30,000 hours. Low loss, highly loaded airfoils are used to increase efficiency while reducing the parts count. Active clearance control and case trenches in abradable strips over the blade tips are included in the compressor component design to further increase the efficiency potential. The test rig incorporates variable geometry stator vanes in all stages to permit maximum flexibility in developing stage-to-stage matching. This provision precluded active clearance control on the rear case of the test rig. Both the component and rig designs meet or exceed design requirements with the exception of life goals, which will be achievable with planned advances in materials technology.
A Study on the Requirements for Fast Active Turbine Tip Clearance Control Systems
NASA Technical Reports Server (NTRS)
DeCastro, Jonathan A.; Melcher, Kevin J.
2004-01-01
This paper addresses the requirements of a control system for active turbine tip clearance control in a generic commercial turbofan engine through design and analysis. The control objective is to articulate the shroud in the high pressure turbine section in order to maintain a certain clearance set point given several possible engine transient events. The system must also exhibit reasonable robustness to modeling uncertainties and reasonable noise rejection properties. Two actuators were chosen to fulfill such a requirement, both of which possess different levels of technological readiness: electrohydraulic servovalves and piezoelectric stacks. Identification of design constraints, desired actuator parameters, and actuator limitations are addressed in depth; all of which are intimately tied with the hardware and controller design process. Analytical demonstrations of the performance and robustness characteristics of the two axisymmetric LQG clearance control systems are presented. Takeoff simulation results show that both actuators are capable of maintaining the clearance within acceptable bounds and demonstrate robustness to parameter uncertainty. The present model-based control strategy was employed to demonstrate the tradeoff between performance, control effort, and robustness and to implement optimal state estimation in a noisy engine environment with intent to eliminate ad hoc methods for designing reliable control systems.
19 CFR 122.158 - Other entry and clearance requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Other entry and clearance requirements. 122.158 Section 122.158 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Flights to and From Cuba § 122.158 Other entry and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-24
... Activities: Requests for Comments; Clearance of New Approval of Information Collection: Activation of Ice... requirement imposed by the new rule ``Part 121 Activation of Ice Protection''. The NPRM for that rule was...: Activation of Ice Protection Rule--Flight Manual Requirements. Form Numbers: There are no FAA forms...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-23
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services [Document Identifier: CMS-10510] Emergency Clearance: Public Information Collection Requirements Submitted to the Office of Management and Budget (OMB) AGENCY: Centers for Medicare & Medicaid Services, HHS. In compliance with section 3506(c)(2)(A) of the Paperwork...
Development of a Novel System to Measure a Clearance of a Passenger Platform
NASA Astrophysics Data System (ADS)
Shimizu, M.; Oizumi, J.; Matsuoka, R.; Takeda, H.; Okukura, H.; Ooya, A.; Koike, A.
2016-06-01
Clearances of a passenger platform at a railway station should be appropriately maintained for safety of both trains and passengers. In most Japanese railways clearances between a platform and a train car is measured precisely once or twice a year. Because current measurement systems operate on a track, the closure of the track is unavoidable. Since the procedure of the closure of a track is time-consuming and bothersome, we decided to develop a new system to measure clearances without the closure of a track. A new system is required to work on a platform and the required measurement accuracy is less than several millimetres. We have adopted a 3D laser scanner and stop-and-go operation for a new system. The current systems on a track measure clearances continuously at walking speed, while our system on a platform measures clearances at approximately ten metres intervals. The scanner controlled by a PC acquires a set of point data at each measuring station. Edge points of the platform, top and side points of two rails are detected from the acquired point data. Finally clearances of the platform are calculated by using the detected feature points of the platform and the rails. The results of an experiment using a prototype of our system show that the measurement accuracy by our system would be satisfactory, but our system would take more time than the current systems. Since our system requires no closure of a track, we conclude that our system would be convenient and effective.
Aerial Refueling Clearance Initiation Request
2016-07-14
and receiver agencies. The AR Clearance Initiation Request document recognizes the requirement for definitive aerial refueling agreements between...and contractual tanker support requests from one organization or nation to another. The AR Clearance Initiation Request document is not intended to...proprietary, sensitive, classified or otherwise restricted information. ARSAG documents, as prepared, are not DOD, MOD or NATO standards, but provide
Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane
NASA Technical Reports Server (NTRS)
Gera, Joseph; Bosworth, John T.
1987-01-01
Initial envelope clearance and subsequent flight testing of a new, fully augmented airplane with an extremely high degree of static instability can place unusual demands on the flight test approach. Previous flight test experience with these kinds of airplanes is very limited or nonexistent. The safe and efficient flight testing may be further complicated by a multiplicity of control effectors that may be present on this class of airplanes. This paper describes some novel flight test and analysis techniques in the flight dynamics and handling qualities area. These techniques were utilized during the initial flight envelope clearance of the X-29A aircraft and were largely responsible for the completion of the flight controls clearance program without any incidents or significant delays.
Leypoldt, John K; Kamerath, Craig D; Gilson, Janice F; Friederichs, Goetz
2006-01-01
New daily hemodialysis therapies operate at low dialysate flow rates to minimize dialysate volume requirements; however, the dependence of dialyzer clearances and mass transfer-area coefficients for small solutes on dialysate flow rate under these conditions have not been studied extensively. We evaluated in vitro dialyzer clearances for urea and creatinine at dialysate flow rates of 40, 80, 120, 160, and 200 ml/min and ultrafiltration flow rates of 0, 1, and 2 l/h, using a dialyzer containing PUREMA membranes (NxStage Medical, Lawrence, MA). Clearances were measured directly across the dialyzer by perfusing bovine blood with added urea and creatinine single pass through the dialyzer at a nominal blood flow rate of 400 ml/min. Limited, additional studies were performed with the use of dialyzers containing PUREMA membranes at a blood flow rate of 200 ml/min and also with the use of other dialyzers containing polysulfone membranes (Optiflux 160NR, FMC-NA, Ogden, UT) and dialyzers containing Synphan membranes (NxStage Medical). For dialyzers containing PUREMA membranes, urea and creatinine clearances increased (p < 0.001) with increasing dialysate and ultrafiltration flow rates but were not different at blood flow rates of 200 and 400 ml/min. Dialysate saturation, defined as dialysate outlet concentration divided by blood water inlet concentration, for urea and creatinine was independent of blood and ultrafiltration flow rate but varied inversely (p < 0.001) with dialysate flow rate. Mass transfer-area coefficients for urea and creatinine were independent of blood and ultrafiltration flow rate but decreased (p < 0.001) with decreasing dialysate flow rate. Calculated mass transfer-area coefficients at low dialysate flow rates for all dialyzers tested were substantially lower than those reported by the manufacturers under conventional conditions. We conclude that dialyzers require specific characterization under relevant conditions if they are used in novel daily hemodialysis therapies at low dialysate flow rate.
Recent advances in capacitance type of blade tip clearance measurements
NASA Technical Reports Server (NTRS)
Barranger, John P.
1988-01-01
Two recent electronic advances at NASA-Lewis that meet the blade tip clearance needs of a wide class of fans, compressors, and turbines are described. The first is a frequency modulated (FM) oscillator that requires only a single low cost ultrahigh frequency operational amplifier. Its carrier frequency is 42.8 MHz when used with a 61 cm long hermetically sealed coaxial cable. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a typical rotor blade. High temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum which produces a clearance error of + or - 10 microns at a clearance of 500 microns. In the second advance, a guarded probe configuration allows a longer cable capacitance. The capacitance of the probe is part of a small time constant feedback in a high speed operational amplifier. The solution of the governing differential equation is applied to a ramp type of input. The results show an amplifier output that contains a term which is proportional to the derivative of the feedback capacitance. The capacitance is obtained by subtracting a balancing reference channel followed by an integration stage.
NASA Astrophysics Data System (ADS)
Thapa, B. S.; Dahlhaug, O. G.; Thapa, B.
2016-11-01
In Francis turbine, a small clearance gap between the guide vanes and the cover plates is usually required to pivot guide vanes as a part of governing system. Deflection of cover plates and erosion of mating surfaces causes this gap to increase from its design value. The clearance gap induces the secondary flow in the distributor system. This effects the main flow at the runner inlet, which causes losses in efficiency and instability. A guide vane cascade of a low specific speed Francis turbine has been developed for experimental investigations. The test setup is able to produce similar velocity distributions at the runner inlet as that of a reference prototype turbine. The setup is designed for particle image velocimetry (PIV) measurements from the position of stay vane outlet to the position of runner inlet. In this study, velocity and pressure measurements are conducted with 2 mm clearance gap on one side of guide vane. Leakage flow is observed and measured together with pressure measurements. It is concluded that the leakage flow behaves as a jet and mixes with the main flow in cross-wise direction and forms a vortex filament. This causes non-uniform inlet flow conditions at runner blades.
Delayed clearance of triglyceride‐rich lipoproteins in young, healthy obese subjects†
Goll, R.; Lekahl, S.; Moen, O. S.; Florholmen, J.
2015-01-01
Summary Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age‐ and sex‐matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA‐IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA‐IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. PMID:26469529
Flight Crew Responses to the Interval Management Alternative Clearances (IMAC) Experiment
NASA Technical Reports Server (NTRS)
Baxley, Brian T.; Wilson, Sara R.; Swieringa, Kurt A.; Roper, Roy D.
2016-01-01
Interval Management Alternative Clearances (IMAC) was a human-in-the-loop simulation experiment conducted to explore the efficacy and acceptability of three IM operations: CAPTURE, CROSS, and MAINTAIN. Two weeks of data collection were conducted, with each week using twelve subject pilots and four subject controllers flying ten high-density arrival scenarios into the Denver International Airport. Overall, both the IM operations and procedures were rated very favorably by the flight crew in terms of acceptability, workload, and pilot head down time. However, several critical issues were identified requiring resolution prior to real-world implementation, including the high frequency of IM speed commands, IM speed commands requiring changes to aircraft configuration, and ambiguous IM cockpit displays that did not trigger the intended pilot reaction. The results from this experiment will be used to prepare for a flight test in 2017, and to support the development of an advanced IM concept of operations by the FAA (Federal Aviation Agency) and aviation industry.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 2 2013-10-01 2013-10-01 false Clearance and Documentation Requirements-Shipments to DOD Air or Water Terminal Transshipment Points. 52.247-52 Section 52.247-52 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES...
2015 Annual Report on Security Clearance Determinations
2016-06-28
completed or pending security clearance determinations for government employees and contractors during the preceding fiscal year that have taken longer...each level during the preceding fiscal year. Similar data pertaining to USG contractors is also required. Also, for each element of the Intelligence...for USG Employees and USG Contractors Security Clearance Determination Processing Metrics for the Seven IC Agencies The number of individuals
NASA Technical Reports Server (NTRS)
Underwood, Matthew C.
2017-01-01
To provide justification for equipping a fleet of aircraft with avionics capable of supporting trajectory-based operations, significant flight testing must be accomplished. However, equipping aircraft with these avionics and enabling technologies to communicate the clearances required for trajectory-based operations is cost-challenging using conventional avionics approaches. This paper describes an approach to minimize the costs and risks of flight testing these technologies in-situ, discusses the test-bed platform developed, and highlights results from a proof-of-concept flight test campaign that demonstrates the feasibility and efficiency of this approach.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
...: Proposed Collection; Comment Request--Generic Clearance to Conduct Methodological Testing, Surveys, Focus... proposed information collection. This information collection will conduct research by methodological... Methodological Testing, Surveys, Focus Groups, and Related Tools to Improve the Management of Federal Nutrition...
Estimation of Glomerular Filtration Rate from Plasma Clearance of 51-Chromium Edetic Acid
Chantler, C.; Barratt, T. M.
1972-01-01
The glomerular filtration rate was estimated by a single compartment analysis of the rate of fall of plasma concentration of 51-chromium edetic acid after a single intravenous injection. This slope clearance consistently overestimated the simultaneously determined standard urinary clearance, but could be used to predict the latter with an accuracy of ±9% (95% confidence limits). The coefficient of variation of replicate estimates of the slope clearance in the same individual was 3·9%; thus two estimates of glomerular filtration rate by this technique which differ by 11% have a 95% probability of reflecting a genuine difference. The method requires an intravenous injection and blood samples at 2 and 4 hours; urine samples are not required. It is simple, safe, and precise, and is applicable to children. PMID:4625784
The tear turnover and tear clearance tests - a review.
Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño
2018-03-01
The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.
Dynamic Performance of High Bypass Ratio Turbine Engines With Water Ingestion
NASA Technical Reports Server (NTRS)
Murthy, S. N. B.
1996-01-01
The research on dynamic performance of high bypass turbofan engines includes studies on inlets, turbomachinery and the total engine system operating with air-water mixture; the water may be in vapor, droplet, or film form, and their combinations. Prediction codes (WISGS, WINCOF, WINCOF-1, WINCLR, and Transient Engine Performance Code) for performance changes, as well as changes in blade-casing clearance, have been established and demonstrated in application to actual, generic engines. In view of the continuous changes in water distribution in turbomachinery, the performance of both components and the total engine system must be determined in a time-dependent mode; hence, the determination of clearance changes also requires a time-dependent approach. In general, the performance and clearances changes cannot be scaled either with respect to operating or ingestion conditions. Removal of water prior to phase change is the most effective means of avoiding ingestion effects. Sufficient background has been established to perform definitive, full scale tests on a set of components and a complete engine to establish engine control and operability with various air-water vapor-water mixtures.
Jehu, Deborah A; Lajoie, Yves; Paquet, Nicole
2017-12-21
The purpose of this study was to investigate obstacle clearance and reaction time parameters when crossing a series of six obstacles in older adults. A second aim was to examine the repeated exposure of this testing protocol once per week for 5 weeks. In total, 10 older adults (five females; age: 67.0 ± 6.9 years) walked onto and over six obstacles of varying heights (range: 100-200 mm) while completing no reaction time, simple reaction time, and choice reaction time tasks once per week for 5 weeks. The highest obstacles elicited the lowest toe clearance, and the first three obstacles revealed smaller heel clearance compared with the last three obstacles. Dual tasking negatively impacted obstacle clearance parameters when information processing demands were high. Longer and less consistent time to completion was observed in Session 1 compared with Sessions 2-5. Finally, improvements in simple reaction time were displayed after Session 2, but choice reaction time gradually improved and did not reach a plateau after repeated testing.
Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor
NASA Astrophysics Data System (ADS)
Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai
2012-08-01
Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.
Lottrup, Christian; Krarup, Anne L; Gregersen, Hans; Ejstrud, Per; Drewes, Asbjørn M
2016-01-01
Background/Aims Impaired esophageal acid clearance may be a contributing factor in the pathogenesis of Barrett’s esophagus. However, few studies have measured acid clearance as such in these patients. In this explorative, cross-sectional study, we aimed to compare esophageal acid clearance and swallowing rate in patients with Barrett’s esophagus to that in healthy controls. Methods A total of 26 patients with histology-confirmed Barrett’s esophagus and 12 healthy controls underwent (1) upper endoscopy, (2) an acid clearance test using a pH-impedance probe under controlled conditions including controlled and random swallowing, and (3) an ambulatory pH-impedance measurement. Results Compared with controls and when swallowing randomly, patients cleared acid 46% faster (P = 0.008). Furthermore, patients swallowed 60% more frequently (mean swallows/minute: 1.90 ± 0.74 vs 1.19 ± 0.58; P = 0.005), and acid clearance time decreased with greater random swallowing rate (P < 0.001). Swallowing rate increased with lower distal esophageal baseline impedance (P = 0.014). Ambulatory acid exposure was greater in patients (P = 0.033), but clearance times assessed from the ambulatory pH-measurement and acid clearance test were not correlated (all P > 0.3). Conclusions More frequent swallowing and thus faster acid clearance in Barrett’s esophagus may constitute a protective reflex due to impaired mucosal integrity and possibly acid hypersensitivity. Despite these reinforced mechanisms, acid clearance ability seems to be overthrown by repeated, retrograde acid reflux, thus resulting in increased esophageal acid exposure and consequently mucosal changes. PMID:27557545
Simple geometric algorithms to aid in clearance management for robotic mechanisms
NASA Technical Reports Server (NTRS)
Copeland, E. L.; Ray, L. D.; Peticolas, J. D.
1981-01-01
Global geometric shapes such as lines, planes, circles, spheres, cylinders, and the associated computational algorithms which provide relatively inexpensive estimates of minimum spatial clearance for safe operations were selected. The Space Shuttle, remote manipulator system, and the Power Extension Package are used as an example. Robotic mechanisms operate in quarters limited by external structures and the problem of clearance is often of considerable interest. Safe clearance management is simple and suited to real time calculation, whereas contact prediction requires more precision, sophistication, and computational overhead.
Chachu, Karen A.; LoBue, Anna D.; Strong, David W.; Baric, Ralph S.; Virgin, Herbert W.
2008-01-01
Two cardinal manifestations of viral immunity are efficient clearance of acute infection and the capacity to vaccinate against secondary viral exposure. For noroviruses, the contributions of T cells to viral clearance and vaccination have not been elucidated. We report here that both CD4 and CD8 T cells are required for efficient clearance of primary murine norovirus (MNV) infection from the intestine and intestinal lymph nodes. Further, long-lasting protective immunity was generated by oral live virus vaccination. Systemic vaccination with the MNV capsid protein also effectively protected against mucosal challenge, while vaccination with the capsid protein of the distantly related human Lordsdale virus provided partial protection. Fully effective vaccination required a broad immune response including CD4 T cells, CD8 T cells, and B cells, but the importance of specific immune cell types varied between the intestine and intestinal lymph nodes. Perforin, but not interferon gamma, was required for clearance of MNV infection by adoptively transferred T lymphocytes from vaccinated hosts. These studies prove the feasibility of both mucosal and systemic vaccination against mucosal norovirus infection, demonstrate tissue specificity of norovirus immune cells, and indicate that efficient vaccination strategies should induce potent CD4 and CD8 T cell responses. PMID:19079577
CF6 High Pressure Compressor and Turbine Clearance Evaluations
NASA Technical Reports Server (NTRS)
Radomski, M. A.; Cline, L. D.
1981-01-01
In the CF6 Jet Engine Diagnostics Program the causes of performance degradation were determined for each component of revenue service engines. It was found that a significant contribution to performance degradation was caused by increased airfoil tip radial clearances in the high pressure compressor and turbine areas. Since the influence of these clearances on engine performance and fuel consumption is significant, it is important to accurately establish these relatonships. It is equally important to understand the causes of clearance deterioration so that they can be reduced or eliminated. The results of factory engine tests run to enhance the understanding of the high pressure compressor and turbine clearance effects on performance are described. The causes of clearance deterioration are indicated and potential improvements in clearance control are discussed.
10 CFR 110.121 - Security clearances and access to classified information.
Code of Federal Regulations, 2011 CFR
2011-01-01
... be granted unless required security clearances have been obtained. (h) For good cause, the Commission... the common defense and security; and (2) Which it has received from another Government agency, without...
Relationship between rhinosinusitis symptoms and mucociliary clearance time.
Boatsman, Justin E; Calhoun, Karen H; Ryan, Matthew W
2006-03-01
To determine the correlation between rhinosinusitis symptoms as assessed by the Sino-Nasal Outcomes Test-20 (SNOT-20) and mucociliary clearance as assessed by the saccharin method. This was a cross-sectional study of 50 adult volunteers. Subjects completed the SNOT-20, and mucociliary clearance was determined with the saccharine method. Correlation coefficients (Spearman's Rho) were calculated for the global SNOT-20 score. The SNOT-20 scores varied from 20 to 54 (mean 30.28) with a possible range of 20 to 100. Clearance times varied from 418 to 2865 seconds (mean 999). There was no significant correlation between global SNOT-20 score and clearance time (r = 0.196). There is no significant correlation between rhinosinusitis symptoms as assessed by SNOT-20 scores and mucociliary clearance. Mucociliary clearance is important for the health of the sinonasal cavities, but clearance time does not appear to be associated with symptom severity in the population studied. A-1b.
NASA Technical Reports Server (NTRS)
Klassen, H. A.; Wood, J. R.; Schumann, L. F.
1977-01-01
A 13.65 cm tip diameter backswept centrifugal impeller having a tandem inducer and a design mass flow rate of 0.907 kg/sec was experimentally investigated to establish stage and impeller characteristics. Tests were conducted with both a cascade diffuser and a vaneless diffuser. A pressure ratio of 5.9 was obtained near surge for the smallest clearance tested. Flow range at design speed was 6.3 percent for the smallest clearance test. Impeller exit to shroud axial clearance at design speed was varied to determine the effect on stage and impeller performance.
How much medicine do spine surgeons need to know to better select and care for patients?
Epstein, Nancy E.
2012-01-01
Background: Although we routinely utilize medical consultants for preoperative clearance and postoperative patient follow-up, we as spine surgeons need to know more medicine to better select and care for our patients. Methods: This study provides additional medical knowledge to facilitate surgeons’ “cross-talk” with medical colleagues who are concerned about how multiple comorbid risk factors affect their preoperative clearance, and impact patients’ postoperative outcomes. Results: Within 6 months of an acute myocardial infarction (MI), patients undergoing urological surgery encountered a 40% mortality rate: similar rates may likely apply to patients undergoing spinal surgery. Within 6 weeks to 2 months of placing uncoated cardiac, carotid, or other stents, endothelialization is typically complete; as anti-platelet therapy may often be discontinued, spinal surgery can then be more safely performed. Coated stents, however, usually require 6 months to 1 year for endothelialization to occur; thus spinal surgery is often delayed as anti-platelet therapy must typically be continued to avoid thrombotic complications (e.g., stroke/MI). Diabetes and morbid obesity both increase the risk of postoperative infection, and poor wound healing, while the latter increases the risk of phlebitis/pulmonary embolism. Both hypercoagluation and hypocoagulation syndromes may require special preoperative testing/medications and/or transfusions of specific hematological factors. Pulmonary disease, neurological disorders, and major psychiatric pathology may also require further evaluations/therapy, and may even preclude successful surgical intervention. Conclusions: Although we as spinal surgeons utilize medical consultants for preoperative clearance and postoperative care, we need to know more medicine to better select and care for our patients. PMID:23248752
NASA Technical Reports Server (NTRS)
Szanca, E. M.; Behning, F. P.; Schum, H. J.
1974-01-01
A 25.4-cm (10-in) tip diameter turbine was tested to determine the effect of rotor radial tip clearance on turbine overall performance. The test turbine was a half-scale model of a 50.8-cm-(20-in.-) diameter research turbine designed for high-temperature core engine application. The test turbine was fabricated with solid vanes and blades with no provision for cooling air and tested at much reduced inlet conditions. The tests were run at design speed over a range of pressure ratios for three different rotor clearances ranging from 2.3 to 6.7 percent of the annular blade passage height. The results obtained are compared to the results obtained with three other turbines of varying amounts of reaction.
Bard, Frédérique; Barbour, Robin; Cannon, Catherine; Carretto, Robert; Fox, Michael; Games, Dora; Guido, Teresa; Hoenow, Kathleen; Hu, Kang; Johnson-Wood, Kelly; Khan, Karen; Kholodenko, Dora; Lee, Celeste; Lee, Mike; Motter, Ruth; Nguyen, Minh; Reed, Amanda; Schenk, Dale; Tang, Pearl; Vasquez, Nicki; Seubert, Peter; Yednock, Ted
2003-01-01
Transgenic PDAPP mice, which express a disease-linked isoform of the human amyloid precursor protein, exhibit CNS pathology that is similar to Alzheimer's disease. In an age-dependent fashion, the mice develop plaques containing β-amyloid peptide (Aβ) and exhibit neuronal dystrophy and synaptic loss. It has been shown in previous studies that pathology can be prevented and even reversed by immunization of the mice with the Aβ peptide. Similar protection could be achieved by passive administration of some but not all monoclonal antibodies against Aβ. In the current studies we sought to define the optimal antibody response for reducing neuropathology. Immune sera with reactivity against different Aβ epitopes and monoclonal antibodies with different isotypes were examined for efficacy both ex vivo and in vivo. The studies showed that: (i) of the purified or elicited antibodies tested, only antibodies against the N-terminal regions of Aβ were able to invoke plaque clearance; (ii) plaque binding correlated with a clearance response and neuronal protection, whereas the ability of antibodies to capture soluble Aβ was not necessarily correlated with efficacy; (iii) the isotype of the antibody dramatically influenced the degree of plaque clearance and neuronal protection; (iv) high affinity of the antibody for Fc receptors on microglial cells seemed more important than high affinity for Aβ itself; and (v) complement activation was not required for plaque clearance. These results indicate that antibody Fc-mediated plaque clearance is a highly efficient and effective process for protection against neuropathology in an animal model of Alzheimer's disease. PMID:12566568
NASA Technical Reports Server (NTRS)
Chupp, Raymond E.; Hendricks, Robert C.; Lattime, Scott B.; Steinetz, Bruce M.
2006-01-01
Clearance control is of paramount importance to turbomachinery designers and is required to meet today's aggressive power output, efficiency, and operational life goals. Excessive clearances lead to losses in cycle efficiency, flow instabilities, and hot gas ingestion into disk cavities. Insufficient clearances limit coolant flows and cause interface rubbing, overheating downstream components and damaging interfaces, thus limiting component life. Designers have put renewed attention on clearance control, as it is often the most cost effective method to enhance system performance. Advanced concepts and proper material selection continue to play important roles in maintaining interface clearances to enable the system to meet design goals. This work presents an overview of turbomachinery sealing to control clearances. Areas covered include: characteristics of gas and steam turbine sealing applications and environments, benefits of sealing, types of standard static and dynamics seals, advanced seal designs, as well as life and limitations issues.
Prechamber Compression-Ignition Engine Performance
NASA Technical Reports Server (NTRS)
Moore, Charles S; Collins, John H , Jr
1938-01-01
Single-cylinder compression-ignition engine tests were made to investigate the performance characteristics of prechamber type of cylinder head. Certain fundamental variables influencing engine performance -- clearance distribution, size, shape, and direction of the passage connecting the cylinder and prechamber, shape of prechamber, cylinder clearance, compression ratio, and boosting -- were independently tested. Results of motoring and of power tests, including several typical indicator cards, are presented.
Ferin, J; Leach, L J
1975-09-01
A procedure utilizing the lung clearance kinetics of titanic oxide (TiO2) particles was used to determine the effects of inhaled sulphur dioxide (SO2) and nitrogen oxides (NO x) on particle clearance. The procedure is reproducible and mainly tests clearance mechanisms involving alveolar macrophages and the mucociliary transport system at the alveolobronchial clearance pathway. At low SO2 or NOx exposures enhanced particle clearance was observed. Lung clearance was depressed at 15 and 24 ppm of NO2 after 22 exposures as well as at 20 ppm of SO2 after 11 exposures, and also at 1 ppm of SO2 after 25 exposures. Dose-response curves for the SO2 and NOx exposures showed differences explainable by the routes by which these gases reach the alveolar macrophages.
Low-cost FM oscillator for capacitance type of blade tip clearance measurement system
NASA Technical Reports Server (NTRS)
Barranger, John P.
1987-01-01
The frequency-modulated (FM) oscillator described is part of a blade tip clearance measurement system that meets the needs of a wide class of fans, compressors, and turbines. As a result of advancements in the technology of ultra-high-frequency operational amplifiers, the FM oscillator requires only a single low-cost integrated circuit. Its carrier frequency is 42.8 MHz when it is used with an integrated probe and connecting cable assembly consisting of a 0.81 cm diameter engine-mounted capacitance probe and a 61 cm long hermetically sealed coaxial cable. A complete circuit analysis is given, including amplifier negative resistance characteristics. An error analysis of environmentally induced effects is also derived, and an error-correcting technique is proposed. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a rotor blade thickness of 1.2 mm. High-temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum permissible seal temperature. The major source of error is the residual FM oscillator noise, which produces a clearance error of + or - 10 microns at a clearance of 0.5 mm. The oscillator electronics accommodates the high rotor speeds associated with small engines, the signals from which may have frequency components as high as 1 MHz.
Test Rig for Active Turbine Blade Tip Clearance Control Concepts: An Update
NASA Technical Reports Server (NTRS)
Taylor, Shawn; Steinetz, Bruce; Oswald, Jay; DeCastro, Jonathan; Melcher, Kevin
2006-01-01
The objective is to develop and demonstrate a fast-acting active clearance control system to improve turbine engine performance, reduce emissions, and increase service life. System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA's Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.
75 FR 27997 - Notice of Proposed Information Collection Requests
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-19
..., Information Collection Clearance Division, Regulatory Information Management Services, Office of Management... information collection requests. The Office of Management and Budget (OMB) may amend or waive the requirement... Collection Clearance Division, Regulatory Information Management Services, Office of Management, publishes...
Online monitoring of dynamic tip clearance of turbine blades in high temperature environments
NASA Astrophysics Data System (ADS)
Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang
2018-04-01
Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.
Low Vertical Clearance Truss Bridges : Risk Assessment and Retrofit Mitigation Study
DOT National Transportation Integrated Search
2017-11-10
The Washington State Department of Transportation (WSDOT) has over 60 steel truss bridges in its inventory with vertical clearances less than the minimum 16-6 required for new bridges. This study evaluates the risks of oversized vehicle impacts...
NASA Technical Reports Server (NTRS)
Montalyo, Michael L.; Lebacqz, J. Victor (Technical Monitor)
1994-01-01
Airlines operating in the United States are required to operate under instrument flight rules (EFR). Typically, a clearance is issued via voice transmission from clearance delivery at the departing airport. In 1990, the Federal Aviation Administration (FAA) began deployment of the Pre-Departure Clearance (PDC) system at 30 U.S. airports. The PDC system utilizes aeronautical datalink and Aircraft Communication and Reporting System (ACARS) to transmit departure clearances directly to the pilot. An objective of the PDC system is to provide an immediate reduction in voice congestion over the clearance delivery frequency. Participating airports report that this objective has been met. However, preliminary analysis of 42 Aviation Safety Reporting System (ASRS) reports has revealed problems in PDC procedures and formatting which have caused errors in the proper execution of the clearance. It must be acknowledged that this technology, along with other advancements on the flightdeck, is adding more responsibility to the crew and increasing the opportunity for error. The present study uses these findings as a basis for further coding and analysis of an additional 82 reports obtained from an ASRS database search. These reports indicate that clearances are often amended or exceptions are added in order to accommodate local ATC facilities. However, the onboard ACARS is limited in its ability to emphasize or highlight these changes which has resulted in altitude and heading deviations along with increases in ATC workload. Furthermore, few participating airports require any type of PDC receipt confirmation. In fact, 35% of all ASRS reports dealing with PDC's include failure to acquire the PDC at all. Consequently, this study examines pilots' suggestions contained in ASRS reports in order to develop recommendations to airlines and ATC facilities to help reduce the amount of incidents that occur.
NASA Technical Reports Server (NTRS)
Moore, R. D.
1982-01-01
The effects of tip clearance on the overall and blade-element performance of an axial-flow transonic fan stage are presented. The 50-centimeter-diameter fan was tested at four tip clearances (nonrotating) from 0.061 to 0.178 centimeter. The calculated radial growth of the blades was 0.040 centimeter at design conditions. The decrease in overall stage performance with increasing clearance is attributed to the loss in rotor performance. For the rotor the effects of clearance on performance parameters extended to about 70 percent of blade span from the tip. The stage still margin based on an assumed operating line decreased from 15.3 to 0 percent as the clearance increased from 0.061 to 0.178 centimeter.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-31
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: License Requirements for Operation of a Launch Site AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice...
A Comprehensive Pregnancy and Family Medical Care Leave Program for the 21st Century
1999-04-21
of a serious medical condition. Although this policy may not be ideal or even sufficient for the Army individual or family, given the physical nature...All provide: a. exemptions from physical fitness and testing during antenatal and postpartum periods b. duty restrictions at specified times in a...guarantee of reenlistment or new officer appointment provided the returning service member can meet physical standards and security clearance requirements
Dexmedetomidine metabolic clearance is not affected by fat mass in obese patients.
Rolle, A; Paredes, S; Cortínez, L I; Anderson, B J; Quezada, N; Solari, S; Allende, F; Torres, J; Cabrera, D; Contreras, V; Carmona, J; Ramírez, C; Oliveros, A M; Ibacache, M
2018-05-01
Obesity has been associated with reduced dexmedetomidine clearance, suggesting impaired hepatic function or reduced hepatic blood flow. The aim of this study was to clarify the effect of obesity in dexmedetomidine metabolic clearance. Forty patients, ASA I-III, 18-60 yr old, weighing 47-126 kg, scheduled for abdominal laparoscopic surgery, were enrolled. Anaesthetic agents (propofol, remifentanil, and dexmedetomidine) were dosed based on lean body weight measured by dual X-ray absorptiometry. Serial venous samples were drawn during and after dexmedetomidine infusion. A pharmacokinetic analysis was undertaken using non-linear mixed-effect models. In the modelling approach, the total body weight, lean body weight, and adjusted body weight were first tested as size descriptors for volumes and clearances. Hepatic blood flow, liver histopathology, liver enzymes, and gene expression of metabolic enzymes (UGT2B10 and UGT1A4) were tested as covariates of dexmedetomidine metabolic clearance. A decrease in NONMEM objective function value (ΔOFV) of 3.84 points, for an added parameter, was considered significant at the 0.05 level. A total of 637 dexmedetomidine serum samples were obtained. A two-compartmental model scaled to measured lean weight adequately described the dexmedetomidine pharmacokinetics. Liver blood flow was a covariate for dexmedetomidine clearance (ΔOFV=-5.878). Other factors, including fat mass, histopathological damage, and differential expression of enzymes, did not affect the dexmedetomidine clearance in the population studied (ΔOFV<3.84). We did not find a negative influence of obesity in dexmedetomidine clearance when doses were adjusted to lean body weight. Liver blood flow showed a significant effect on dexmedetomidine clearance. NCT02557867. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
Evaluation of asbestos levels in two schools before and after asbestos removal. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karaffa, M.A.; Chesson, J.; Russell, J.
This report presents a statistical evaluation of airborne asbestos data collected at two schools before and after removal of asbestos-containing material (ACM). Although the monitoring data are not totally consistent with new Asbestos Hazard Emergency Response Act (AHERA) requirements and recent EPA guidelines, the study evaluates these historical data by standard statistical methods to determine if abated work areas meet proposed clearance criteria. The objectives of this statistical analysis were to compare (1) airborne asbestos levels indoors after removal with levels outdoors, (2) airborne asbestos levels before and after removal of asbestos, and (3) static sampling and aggressive sampling ofmore » airborne asbestos. The results of this evaluation indicated the following: the effect of asbestos removal on indoor air quality is unpredictable; the variability in fiber concentrations among different sampling sites within the same building indicates the need to treat different sites as separate areas for the purpose of clearance; and aggressive sampling is appropriate for clearance testing because it captures more entrainable asbestos structures. Aggressive sampling lowers the chance of declaring a worksite clean when entrainable asbestos is still present.« less
Evaluation of an Active Clearance Control System Concept
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M.; Lattime, Scott B.; DeCastro, Jonathan A.; Oswald, Jay; Melcher, Kevin J.
2005-01-01
Reducing blade tip clearances through active tip clearance control in the high pressure turbine can lead to significant reductions in emissions and specific fuel consumption as well as dramatic improvements in operating efficiency and increased service life. Current engines employ scheduled cooling of the outer case flanges to reduce high pressure turbine tip clearances during cruise conditions. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, reburst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). In an effort to improve upon current thermal methods, a first generation mechanically-actuated active clearance control (ACC) system has been designed and fabricated. The system utilizes independent actuators, a segmented shroud structure, and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. Ambient temperature performance tests of this first generation ACC system assessed individual seal component leakage rates and both static and dynamic overall system leakage rates. The ability of the nine electric stepper motors to control the position of the seal carriers in both open- and closed-loop control modes for single and multiple cycles was investigated. The ability of the system to follow simulated engine clearance transients in closed-loop mode showed the system was able to track clearances to within a tight tolerance (0.001 in. error).
Evaluation of an Active Clearance Control System Concept
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M.; Lattime, Scott B.; Taylor, Shawn; DeCastro, Jonathan A.; Oswald, Jay; Melcher, Kevin J.
2005-01-01
Reducing blade tip clearances through active tip clearance control in the high pressure turbine can lead to significant reductions in emissions and specific fuel consumption as well as dramatic improvements in operating efficiency and increased service life. Current engines employ scheduled cooling of the outer case flanges to reduce high pressure turbine tip clearances during cruise conditions. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, reburst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). In an effort to improve upon current thermal methods, a first generation mechanically-actuated active clearance control (ACC) system has been designed and fabricated. The system utilizes independent actuators, a segmented shroud structure, and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. Ambient temperature performance tests of this first generation ACC system assessed individual seal component leakage rates and both static and dynamic overall system leakage rates. The ability of the nine electric stepper motors to control the position of the seal carriers in both open- and closed-loop control modes for single and multiple cycles was investigated. The ability of the system to follow simulated engine clearance transients in closed-loop mode showed the system was able to track clearances to within a tight tolerance ( 0.001 in. error).
Non-Destructive Testing with Atmospheric Pressure Radio-Frequency Plasma
NASA Astrophysics Data System (ADS)
May, A.; Andarawis, E.
2007-03-01
We summarize our recent work using radio-frequency (RF) atmospheric pressure plasma (APP) for non-destructive evaluation (NDE), specifically for: (1) Clearance sensing (0-5mm) on rotating components, and (2) Generation of broadband ultrasound in air at 900kHz. RF-APP showed potential in both of these common NDE requirements, but further work is required to better characterize and optimize the performance of the new techniques. Application of RF-APP to other NDE disciplines, such as plasma spectroscopy and gas flow measurement, is also likely to be advantageous, especially in harsh environments where existing approaches are prohibitively expensive or complex.
Spacesuit and Space Vehicle Comparative Ergonomic Evaluation
NASA Technical Reports Server (NTRS)
England, Scott; Benson, Elizabeth; Cowley, Matthew; Harvill, Lauren; Blackledge, Christopher; Perez, Esau; Rajulu, Sudhakar
2011-01-01
With the advent of the latest manned spaceflight objectives, a series of prototype launch and reentry spacesuit architectures were evaluated for eventual down selection by NASA based on the performance of a set of designated tasks. A consolidated approach was taken to testing, concurrently collecting suit mobility data, seat-suit-vehicle interface clearances and movement strategies within the volume of a Multi-Purpose Crew Vehicle mockup. To achieve the objectives of the test, a requirement was set forth to maintain high mockup fidelity while using advanced motion capture technologies. These seemingly mutually exclusive goals were accommodated with the construction of an optically transparent and fully adjustable frame mockup. The mockup was constructed such that it could be dimensionally validated rapidly with the motion capture system. This paper will describe the method used to create a motion capture compatible space vehicle mockup, the consolidated approach for evaluating spacesuits in action, as well as the various methods for generating hardware requirements for an entire population from the resulting complex data set using a limited number of test subjects. Kinematics, hardware clearance, suited anthropometry, and subjective feedback data were recorded on fifteen unsuited and five suited subjects. Unsuited subjects were selected chiefly by anthropometry, in an attempt to find subjects who fell within predefined criteria for medium male, large male and small female subjects. The suited subjects were selected as a subset of the unsuited subjects and tested in both unpressurized and pressurized conditions. Since the prototype spacesuits were fabricated in a single size to accommodate an approximately average sized male, the findings from the suit testing were systematically extrapolated to the extremes of the population to anticipate likely problem areas. This extrapolation was achieved by first performing population analysis through a comparison of suited subjects performance to their unsuited performance and then applying the results to the entire range of population. The use of a transparent space vehicle mockup enabled the collection of large amounts of data during human-in-the-loop testing. Mobility data revealed that most of the tested spacesuits had sufficient ranges of motion for tasks to be performed successfully. A failed tasked by a suited subject most often stemmed from a combination of poor field of view while seated and poor dexterity of the gloves when pressurized or from suit/vehicle interface issues. Seat ingress/egress testing showed that problems with anthropometric accommodation does not exclusively occur with the largest or smallest subjects, but rather specific combinations of measurements that lead to narrower seat ingress/egress clearance.
33 CFR 149.540 - What are the requirements for obstruction lights on a single point mooring?
Code of Federal Regulations, 2010 CFR
2010-07-01
... located at least 10 feet (3 meters) above mean high water. (b) A submerged turret loading (STL) deepwater... five-foot (1.5 meters) clearance beneath the net under keel clearance at the mean low water condition...
78 FR 64287 - Voluntary Intermodal Sealift Agreement Open Season
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-28
... program. Participants operating vessels in international trade may receive top tier consideration in the... clearance process with DSS. Participants must have a FCL and security clearances at a minimum of SECRET.../intermodal service and resource requirements against industry commitments. JPAG meetings are often SECRET...
Effect of tip clearance on performance of small axial hydraulic turbine
NASA Technical Reports Server (NTRS)
Boynton, J. L.; Rohlik, H. E.
1976-01-01
The first two stages of a six stage liquid oxygen turbine were tested in water. One and two stage performance was determined for one shrouded and two unshrouded blade end configurations over ranges of clearance and blade-jet speed ratio. First stage, two stage, and second stage efficiencies are included as well as the effect of clearance on mass flow for two stage operation.
Wind, Carolien M; Schim van der Loeff, Maarten F; Unemo, Magnus; Schuurman, Rob; van Dam, Alje P; de Vries, Henry J C
2016-06-01
The use of nucleic acid amplification tests (NAATs) to diagnose Neisseria gonorrhoeae infections complicates the performance of a test of cure (TOC) to monitor treatment failure, if this is indicated. As evidence for the timing of TOC using modern NAATs is limited, we performed a prospective cohort study to assess time to clearance when using modern RNA- and DNA-based NAATs. We included patients with anogenital gonorrhoea visiting the Sexually Transmitted Infection Clinic Amsterdam from March through October 2014. After treatment with ceftriaxone mono- or dual therapy (with azithromycin or doxycycline), anal, vaginal, or urine samples were self-collected during 28 consecutive days, and analyzed using an RNA-based NAAT (Aptima Combo 2) and a DNA-based NAAT (Cobas 4800). Clearance was defined as 3 consecutive negative results, and blips as isolated positive results following clearance. We included 77 patients; 5 self-cleared gonorrhoea before treatment and 10 were lost to follow-up. Clearance rate of the remaining 62 patients was 100%. Median time to clearance was 2 days, with a range of 1-7 days for RNA-based NAAT and 1-15 days for DNA-based NAAT. The risk of finding a blip after clearance was 0.8% and 1.5%, respectively. One patient had a reinfection. If indicated, we recommend that TOC be performed for anogenital gonorrhoea at least 7 or 14 days after administering therapy, when using modern RNA- or DNA-based NAATs, respectively. When interpreting TOC results for possible treatment failure, both the occurrence of blips and a possible reinfection need to be taken into account. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Wear in ceramic on ceramic type lumbar total disc replacement: effect of radial clearance.
Shankar, S; Kesavan, D
2015-01-01
The wear of the bearing surfaces of total disc replacement (TDR) is a key problem leads to reduction in the lifetime of the prosthesis and it mainly occurs due to the range of clearances of the articulating surface between the superior plate and core. The objective of this paper is to estimate the wear using finite element concepts considering the different radial clearances between the articulating surfaces of ceramic on ceramic type Lumbar Total Disc Replacement (LTDR). The finite element (FE) model was subjected to wear testing protocols according to loading profile of International Standards Organization (ISO) 18192 standards through 10 million cycles. The radial clearance value of 0.05 mm showed less volumetric wear when compared with other radial clearance values. Hence, low radial clearance values are suitable for LTDR to minimize the wear.
Haque, Shadabul; McLeod, Victoria M; Jones, Seth; Fung, Sandy; Whittaker, Michael; McIntosh, Michelle; Pouton, Colin; Owen, David J; Porter, Christopher J H; Kaminskas, Lisa M
2017-10-01
PEGylated polylysine dendrimers are attractive and well tolerated inhalable drug delivery platforms that have the potential to control the release, absorption kinetics and lung retention time of conjugated drugs. The clinical application of these systems though, would likely require partial substitution of surface PEG groups with drug molecules that are anticipated to alter their lung clearance kinetics and clearance pathways. In the current study, we therefore evaluated the impact of increased surface hydrophobicity via substitution of 50% surface PEG groups with a model hydrophobic drug (α-carboxyl OtButylated methotrexate) on the lung clearance of a Generation 5 PEGylated polylysine dendrimer in rats. PEG substitution with OtBu-methotrexate accelerated lung clearance of the dendrimer by increasing polylysine scaffold catabolism, improving systemic absorption of the intact dendrimer and low molecular weight products of scaffold catabolism, and enhancing mucociliary clearance. These results suggest that the conjugation of hydrophobic drug on the surface of a PEGylated dendrimer is likely to accelerate lung clearance when compared to a fully PEGylated dendrimer. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Comparison of Bite Registration Material Accuracy on in office Laser Scanned Digital Model Occlusion
2014-05-20
School/Department/Center: Two Year Advanced Education in General Dentistry . Fort Bragg,NC 4. Phone:910-429-6626 5. Type of clearance: _X_Paper...Date: 11.~ l~ 4. Higher approval clearance required (for University-, DoD- or US Gov’t-level policy, communication systems or weapons issues review...or US Gov’t-level policy, communications systems or weapons issues review). *Note: It is DoD policy that clearance of information or material
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-08
... precision requirements or power calculations that justify the proposed sample size, the expected response... Qualitative Feedback on Agency Service Delivery AGENCY: Washington Headquarters Service (WHS), DOD. ACTION: 30... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-09
...; Comment Request; Streamlined Clearance Process for Discretionary Grants AGENCY: Department of Education... also helps the public understand the Department's information collection requirements and provide the... for Discretionary Grants OMB Control Number: 1894-0001 Type of Review: An extension of an existing...
Ingress clearance requirements and seat positioning for automatic belt systems
DOT National Transportation Integrated Search
1981-06-01
The purposes of this study were (1) to determine how much clearance between a seat belt and seat cushion is needed for a driver to enter the front seat of an automobile equipped with automatic seat belts---without his/her having to lift the webbing, ...
Radial Clearance Found To Play a Key Role in the Performance of Compliant Foil Air Bearings
NASA Technical Reports Server (NTRS)
Radil, Kevin C.
2003-01-01
Compliant foil air bearings are at the forefront of the Oil-Free turbomachinery revolution, which supports gas turbine engines with hydrodynamic bearings that use air instead of oil as the working fluid. These types of bearings have been around for almost 50 years and have found a home in several commercial applications, such as in air cycle machines, turbocompressors, and microturbines, but are now being aggressively pursued for use in small and midrange aircraft gas turbine engines. Benefits include higher operating speeds and temperatures, lower maintenance costs, and greater reliability. The Oil-Free Turbomachinery team at the NASA Glenn Research Center is working to foster the transition of Oil-Free technology into gas turbine engines by performing in-house experiments on foil air bearings in order to gain a greater insight into their complex operating principles. A research program recently undertaken at Glenn focused on the concept of radial clearance and its influence on bearing performance. The tests were conducted on foil bearings with different radial clearances. As defined for a foil bearing, radial clearance is a measure of the small amount of shaft radial motion that is present from play that exists in the elastic support structure, such as between the top and bump foils and the bump foils and bearing shell (see the drawing). With an insufficient amount of radial clearance, the bearing imparts a high preload on the shaft, which when excessive, can reduce the loadcarrying capability of the bearing. On the other hand, systems using foil bearings with excessive radial clearance may experience rotordynamic instabilities because of low bearing preload. Therefore, without a more thorough understanding of radial clearance, it is difficult to accurately predict the performance of a given bearing design. The test program demonstrated that there is a direct correlation between radial clearance and the performance of foil air bearings. As shown in the graph, an optimum radial clearance exists that will maximize the amount of load that the bearing is capable of supporting. With respect to this optimum, two different performance regimes were observed that are a function of the amount of radial clearance. Tests showed that bearings with radial clearances below the optimum in regime I were susceptible to sudden seizure, a failure mode indicative of thermal runaway caused by high preload. The high preload is in response to an insufficient amount of radial clearance available to accommodate the thermal growth of the bearing and shaft. However, radial clearances greater than the optimum in regime II resulted in low bearing preloads that did not cause any heat-related problems, and the failure mode was due to fluid-film breakdown. In fact, bearings operating with radial clearances twice as much as the optimum suffered a decrease in the maximum load capacity of only about 20 percent. Therefore, special attention has to be given to the range of operating conditions expected in the bearing/shaft system since changes in temperature, centrifugal, and hydrodynamic effects can all affect radial clearance. This enhanced understanding of foil air bearing behavior will greatly aid our efforts to transition Oil-Free technology to future aircraft engines.
Should we consider steps with variable height for a safer stair negotiation in older adults?
Kunzler, Marcos R; da Rocha, Emmanuel S; Dos Santos, Christielen S; Ceccon, Fernando G; Priario, Liver A; Carpes, Felipe P
2018-01-01
Effects of exercise on foot clearances are important. In older adults variations in foot clearances during walking may lead to a fall, but there is a lack of information concerning stair negotiation in older adults. Whether a condition of post exercise changes foot clearances between steps of a staircase in older adults still unknown. To determine differences in clearances when older adults negotiate different steps of a staircase before and after a session of aerobic exercise. Kinematics data from 30 older adults were acquired and the toe and heel clearances were determined for each step. Clearances were compared between the steps. Smaller clearances were found at the highest step during ascending and descending, which was not changed by exercise. Smaller clearances suggest higher risk of tripping at the top of the staircase, regardless of exercise. A smaller step at the top of a short flight of stairs could reduce chances of tripping in older adults. It suggests that steps with variable height could make stair negotiation safer in older adults. This hypothesis should be tested in further studies.
Radioaerosol lung clearance in patients with active pulmonary sarcoidosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, M.P.; Baughman, R.P.; Hughes, J.
1985-05-01
Pulmonary radioaerosol clearance rate of /sup 99m/Tc diethylenetriamine pentacetate (DTPA) in 14 patients with untreated sarcoidosis was compared with /sup 67/Ga lung scan and increased lymphocytes in the bronchoalveolar lavage (BAL) fluid. Nine healthy nonsmoking subjects had a mean DTPA clearance rate of 1.18%/min (range, 0.54 to 1.60%/min). Eight of 14 patients with sarcoidosis had clearance rates greater than 1.60%/min. Of those 8 patients with abnormal DTPA clearance, 4 had positive gallium scans, 4 had more than 17% lymphocytes in the BAL fluid, and 3 had both tests positive. To study the cause of abnormal DTPA clearance, 23 subjects (includingmore » 3 normal controls, all 14 patients with sarcoidosis, and 6 patients with localized disease on chest roentgenogram) underwent both DTPA clearance studies and BAL for quantitation of the amount of albumin in lung fluid. There was a positive correlation between the rate of DTPA clearance and the albumin concentration in lung fluid (r = 0.87, p less than 0.01).« less
Graham, Amy C.; Carr, Karen D.; Sieve, Amy N.; Indramohan, Mohanalaxmi; Break, Timothy J.; Berg, Rance E.
2011-01-01
Listeria monocytogenes (LM) is a gram-positive bacterium that is a common contaminant of processed meats and dairy products. In humans, ingestion of LM can result in intracellular infection of the spleen and liver, which can ultimately lead to septicemia, meningitis, and spontaneous abortion. Interleukin (IL)-23 is a cytokine that regulates innate and adaptive immune responses by inducing the production of IL-17A, IL-17F, and IL-22. We have recently demonstrated that the IL-23/IL-17 axis is required for optimal recruitment of neutrophils to the liver, but not the spleen, during LM infection. Furthermore, these cytokines are required for the clearance of LM during systemic infection. In other infectious models, IL-22 induces the secretion of anti-microbial peptides and protects tissues from damage by preventing apoptosis. However, the role of IL-22 has not been thoroughly investigated during LM infection. In the present study, we show that LM induces the production of IL-22 in vivo. Interestingly, IL-23 is required for the production of IL-22 during primary, but not secondary, LM infection. Our findings suggest that IL-22 is not required for clearance of LM during primary or secondary infection, using both systemic and mucosal models of infection. IL-22 is also not required for the protection of LM infected spleens and livers from organ damage. Collectively, these data indicate that IL-22 produced during LM infection must play a role other than clearance of LM or protection of tissues from pathogen- or immune-mediated damage. PMID:21347242
NASA Technical Reports Server (NTRS)
2005-01-01
The goal of this research is to develop and demonstrate innovative adaptive seal technologies that can lead to dramatic improvements in engine performance, life, range, and emissions, and enhance operability for next generation gas turbine engines. This work is concentrated on the development of self-adaptive clearance control systems for gas turbine engines. Researchers have targeted the high-pressure turbine (HPT) blade tip seal location for following reasons: Current active clearance control (ACC) systems (e.g., thermal case-cooling schemes) cannot respond to blade tip clearance changes due to mechanical, thermal, and aerodynamic loads. As such they are prone to wear due to the required tight running clearances during operation. Blade tip seal wear (increased clearances) reduces engine efficiency, performance, and service life. Adaptive sealing technology research has inherent impact on all envisioned 21st century propulsion systems (e.g. distributed vectored, hybrid and electric drive propulsion concepts).
Shear joint capability versus bolt clearance
NASA Technical Reports Server (NTRS)
Lee, H. M.
1992-01-01
The results of a conservative analysis approach into the determination of shear joint strength capability for typical space-flight hardware as a function of the bolt-hole clearance specified in the design are presented. These joints are comprised of high-strength steel fasteners and abutments constructed of aluminum alloys familiar to the aerospace industry. A general analytical expression was first arrived at which relates bolt-hole clearance to the bolt shear load required to place all joint fasteners into a shear transferring position. Extension of this work allowed the analytical development of joint load capability as a function of the number of fasteners, shear strength of the bolt, bolt-hole clearance, and the desired factor of safety. Analysis results clearly indicate that a typical space-flight hardware joint can withstand significant loading when less than ideal bolt hole clearances are used in the design.
Effect of airway clearance techniques on the efficacy of the sputum induction procedure.
Elkins, M R; Lane, T; Goldberg, H; Pagliuso, J; Garske, L A; Hector, E; Marchetto, L; Alison, J A; Bye, P T P
2005-11-01
Sputum induction is used in the early identification of tuberculosis (TB) and pneumocystis infections of the lung. Although manual physiotherapy techniques to clear the airways are often incorporated in the sputum induction procedure, their efficacy in this setting is unknown. This randomised, crossover trial enrolled adults referred for sputum induction for suspected TB and pneumocystis infections of the lung. All participants underwent two sputum induction procedures, inhaling 3% saline via ultrasonic nebuliser. During one randomly allocated procedure, airway clearance techniques (chest wall percussion, vibration, huffing) were incorporated. In total, 59 participants completed the trial. The airway clearance techniques had no significant effect on how the test was tolerated, the volume expectorated or the quality of the sample obtained (assessed by the presence of alveolar macrophages). The techniques did not significantly affect how often the test identified a suspected organism, nor the sensitivity or specificity of sputum induction. In conclusion, the study was unable to demonstrate any effect of airway clearance techniques on the sputum induction procedure. The results provide some justification for not including airway clearance techniques as part of the sputum induction procedure.
Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane
NASA Technical Reports Server (NTRS)
Gera, Joseph; Bosworth, John T.
1987-01-01
Novel flight test and analysis techniques in the flight dynamics and handling qualities area are described. These techniques were utilized at NASA Ames-Dryden during the initial flight envelope clearance of the X-29A aircraft. It is shown that the open-loop frequency response of an aircraft with highly relaxed static stability can be successfully computed on the ground from telemetry data. Postflight closed-loop frequency response data were obtained from pilot-generated frequency sweeps and it is found that the current handling quality requirements for high-maneuverability aircraft are generally applicable to the X-29A.
78 FR 44931 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-25
... services. The tasks of developing new questions and improving upon existing complaint questions along with... of the generic clearance process. This generic clearance will allow the Bureau to test and pilot new...
Visual Confirmation of Voice Takeoff Clearance (VICON) Alternative Study
DOT National Transportation Integrated Search
1980-05-01
This report presents the results of a program undertaken to study potential alternatives to the VICON (Visual Confirmation of Voice Takeoff Clearance) System which has undergone operational field tests at Bradley International Airport, Windsor Locks,...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-03
... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Pilot Schools... information on FAA Form 8420-8, Application for Pilot School Certificates, is required from applicants who wish to be issued pilot school certificates and associated ratings. DATES: Written comments should be...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-23
... precision requirements or power calculations that justify the proposed sample size, the expected response... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery.'' Also include...
77 FR 63798 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-17
... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Clearance for the Collection of Qualitative Feedback on the Service Delivery of the Consumer Financial... title, ``Generic Clearance for the Collection of Qualitative Feedback on the Service Delivery of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-15
... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... of Qualitative Feedback on Agency Service Delivery AGENCY: Office of the Secretary/Office of the...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Qualitative Feedback on Agency Service Delivery'' for approval under the Paperwork Reduction Act (PRA) (44 U.S...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-31
... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Peace... Qualitative Feedback on Agency Service Delivery '' to OMB for approval under the Paperwork Reduction Act (PRA...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-07
... precision requirements or power calculations that justify the proposed sample size, the expected response... Qualitative Feedback on Agency Service Delivery AGENCY: National Institutes of Health, Eunice Kennedy Shriver...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-18
... precision requirements or power calculations that justify the proposed sample size, the expected response... Activities: Submission for OMB Review; Comment Request; Generic Clearance for the Collection of Qualitative... Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service...
Greater knowledge of biotransformation rates for ionizable organic compounds (IOCs) in fish is required to properly assess the bioaccumulation potential of many environmentally relevant contaminants. In this study we measured in vitro hepatic clearance rates for 50 IOCs using a p...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Training and..., 2011, vol. 76, no. 207, page 66349. The rule allows some experienced pilots who would otherwise qualify...: 2120-0600 . Title: Training and Qualification Requirements for Check Airmen and Flight Instructors...
77 FR 72250 - Airworthiness Directives; Cessna Aircraft Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-05
... rubbing against the right steering tube assembly during rudder pedal actuation. This proposed AD would require you to install the forward and aft fuel return line support clamps and brackets; inspect for a minimum clearance between the fuel return line assembly and the steering tube assembly and clearance...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-13
... Collection; Comments Requested: Leased/Charter Flight Personnel Expedited Clearance Request ACTION: 60-day.../Collection: Leased/Charter Flight Personnel Expedited Clearance Request. (3) Agency form number, if any, and... become contract flight crew members. It is required so that USMS can perform an expedited background...
Gill, Katherine L.; Gertz, Michael; Houston, J. Brian
2013-01-01
A physiologically based pharmacokinetic (PBPK) modeling approach was used to assess the prediction accuracy of propofol hepatic and extrahepatic metabolic clearance and to address previously reported underprediction of in vivo clearance based on static in vitro–in vivo extrapolation methods. The predictive capacity of propofol intrinsic clearance data (CLint) obtained in human hepatocytes and liver and kidney microsomes was assessed using the PBPK model developed in MATLAB software. Microsomal data obtained by both substrate depletion and metabolite formation methods and in the presence of 2% bovine serum albumin were considered in the analysis. Incorporation of hepatic and renal in vitro metabolic clearance in the PBPK model resulted in underprediction of propofol clearance regardless of the source of in vitro data; the predicted value did not exceed 35% of the observed clearance. Subsequently, propofol clinical data from three dose levels in intact patients and anhepatic subjects were used for the optimization of hepatic and renal CLint in a simultaneous fitting routine. Optimization process highlighted that renal glucuronidation clearance was underpredicted to a greater extent than liver clearance, requiring empirical scaling factors of 17 and 9, respectively. The use of optimized clearance parameters predicted hepatic and renal extraction ratios within 20% of the observed values, reported in an additional independent clinical study. This study highlights the complexity involved in assessing the contribution of extrahepatic clearance mechanisms and illustrates the application of PBPK modeling, in conjunction with clinical data, to assess prediction of clearance from in vitro data for each tissue individually. PMID:23303442
Small, high-pressure ratio compressor mechanical acceptance test, volume 2
NASA Technical Reports Server (NTRS)
Metty, G. R.; Shoup, W. I.
1973-01-01
The fabrication and mechanical testing of the high-pressure-ratio compressor are reported. Mechanical testing was performed to demonstrate overspeed capability, adequate rotor dynamics, electrical isolation of the gas bearing trunnion mounted diffuser and shroud and the effect of operating parameters (speed and pressure ratio) on clearance of the compressor test rig. The speed range covered was 20 to 120 percent of rated speed (80,000 rpm). Following these tests an acceptance test which consisted of a 5 hour run at 80,000 rpm was made with approximately design impeller to shroud clearances. For Vol. 1, see N73-26483.
Free-piston Stirling engine/linear alternator 1000-hour endurance test
NASA Technical Reports Server (NTRS)
Rauch, J.; Dochat, G.
1985-01-01
The Free Piston Stirling Engine (FPSE) has the potential to be a long lived, highly reliable, power conversion device attractive for many product applications such as space, residential or remote site power. The purpose of endurance testing the FPSE was to demonstrate its potential for long life. The endurance program was directed at obtaining 1000 operational hours under various test conditions: low power, full stroke, duty cycle and stop/start. Critical performance parameters were measured to note any change and/or trend. Inspections were conducted to measure and compare critical seal/bearing clearances. The engine performed well throughout the program, completing more than 1100 hours. Hardware inspection, including the critical clearances, showed no significant change in hardware or clearance dimensions. The performance parameters did not exhibit any increasing or decreasing trends. The test program confirms the potential for long life FPSE applications.
Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller
NASA Technical Reports Server (NTRS)
Schumann, L. F.; Clark, D. A.; Wood, J. R.
1986-01-01
A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.
Visual Confirmation (VICON) of Takeoff Clearance Signal System Impact Study
DOT National Transportation Integrated Search
1980-11-01
A study was performed to evaluate the impact on airport capacity and voice communications of the Visual Confirmation of Takeoff Clearance (VICON) Signal System. Befoe-and-after test data collection and analysis were conducted at Bradley International...
Estimation of end point foot clearance points from inertial sensor data.
Santhiranayagam, Braveena K; Lai, Daniel T H; Begg, Rezaul K; Palaniswami, Marimuthu
2011-01-01
Foot clearance parameters provide useful insight into tripping risks during walking. This paper proposes a technique for the estimate of key foot clearance parameters using inertial sensor (accelerometers and gyroscopes) data. Fifteen features were extracted from raw inertial sensor measurements, and a regression model was used to estimate two key foot clearance parameters: First maximum vertical clearance (m x 1) after toe-off and the Minimum Toe Clearance (MTC) of the swing foot. Comparisons are made against measurements obtained using an optoelectronic motion capture system (Optotrak), at 4 different walking speeds. General Regression Neural Networks (GRNN) were used to estimate the desired parameters from the sensor features. Eight subjects foot clearance data were examined and a Leave-one-subject-out (LOSO) method was used to select the best model. The best average Root Mean Square Errors (RMSE) across all subjects obtained using all sensor features at the maximum speed for m x 1 was 5.32 mm and for MTC was 4.04 mm. Further application of a hill-climbing feature selection technique resulted in 0.54-21.93% improvement in RMSE and required fewer input features. The results demonstrated that using raw inertial sensor data with regression models and feature selection could accurately estimate key foot clearance parameters.
NASA Astrophysics Data System (ADS)
Boughari, Yamina
New methodologies have been developed to optimize the integration, testing and certification of flight control systems, an expensive process in the aerospace industry. This thesis investigates the stability of the Cessna Citation X aircraft without control, and then optimizes two different flight controllers from design to validation. The aircraft's model was obtained from the data provided by the Research Aircraft Flight Simulator (RAFS) of the Cessna Citation business aircraft. To increase the stability and control of aircraft systems, optimizations of two different flight control designs were performed: 1) the Linear Quadratic Regulation and the Proportional Integral controllers were optimized using the Differential Evolution algorithm and the level 1 handling qualities as the objective function. The results were validated for the linear and nonlinear aircraft models, and some of the clearance criteria were investigated; and 2) the Hinfinity control method was applied on the stability and control augmentation systems. To minimize the time required for flight control design and its validation, an optimization of the controllers design was performed using the Differential Evolution (DE), and the Genetic algorithms (GA). The DE algorithm proved to be more efficient than the GA. New tools for visualization of the linear validation process were also developed to reduce the time required for the flight controller assessment. Matlab software was used to validate the different optimization algorithms' results. Research platforms of the aircraft's linear and nonlinear models were developed, and compared with the results of flight tests performed on the Research Aircraft Flight Simulator. Some of the clearance criteria of the optimized H-infinity flight controller were evaluated, including its linear stability, eigenvalues, and handling qualities criteria. Nonlinear simulations of the maneuvers criteria were also investigated during this research to assess the Cessna Citation X's flight controller clearance, and therefore, for its anticipated certification.
CF6 Jet Engine Performance Improvement: High Pressure Turbine Active Clearance Control
NASA Technical Reports Server (NTRS)
Rich, S. E.; Fasching, W. A.
1982-01-01
An active clearance control system was developed which reduces fuel consumption and performance degradation. This system utilizes compressor discharge air during takeoff and fan discharge air during cruise to impinge on the shroud structure to improve the thermal response. The system was evaluated in component and engine tests. The test results demonstrated a performance improvement of 0.7 percent in cruise SFC.
Retrospective Evaluation of Milrinone Pharmacokinetics in Children With Kidney Injury.
Gist, Katja M; Mizuno, Tomoyuki; Goldstein, Stuart L; Vinks, Alexander
2015-12-01
Milrinone is an inotropic agent with vasodilating properties used in the treatment of ventricular dysfunction. Milrinone is predominantly eliminated by the kidneys and accumulates in the setting of acute kidney injury (AKI). The purpose of this study was to evaluate milrinone pharmacokinetics in children with AKI with or without continuous renal replacement therapy (CRRT). Retrospective collection of milrinone therapeutic drug monitoring data in patients with AKI, including those requiring CRRT, through chart review from January 2008 to March 2014. Pharmacokinetic (PK) data were analyzed by Bayesian estimation using a pediatric population PK model (MW/Pharm). Clearance estimates were allometrically scaled to body weight. Data on 11 patients were available for analysis. Three patients required CRRT. Milrinone concentrations during continuous infusion varied 30-fold and ranged from 44 to 1343 ng/mL. Of the 33 samples obtained in 11 patients, 24 were outside the target range (72.7%), with 16 (48.5%) above and 8 (24.2%) below. Patients with AKI had significantly lower milrinone clearance (4.72 ± 2.26 L/h per 70 kg) compared with published data in patients without AKI. There was large between-patient variability in milrinone clearance (range: 2.91-13.6 L/h per 70 kg). Clearance in patients on CRRT ranged from 2.8 to 7.19 L/h per 70 kg. A significant correlation between milrinone clearance and estimated creatinine clearance was observed (r = 0.70, P = 0.0097). Allometrically scaled milrinone clearance was lower in the youngest patients (younger than 2 years), suggestive of ongoing renal maturation and existing AKI. Pediatric patients with AKI have significantly lower milrinone clearance compared with published data in patients without AKI. Large variability was noted in milrinone concentrations, and they were frequently outside the target range. The large between-patient variability in milrinone concentrations suggests that dosing regimens should be individualized in this population of critically ill patients. Evaluation of PK model-based milrinone dose optimization and the use of biomarkers as predictors of changes in clearance warrant further study.
Advantage I-75 mainline automated clearance system : final evaluation report
DOT National Transportation Integrated Search
1998-08-01
The focus of this evaluation was to determine if the Advantage I-75 Mainline Automated Clearance Systems (MACS) produced significant fuel savings for motor carriers. The fundamental hypothesis tested was that the reduction or elimination of stops at ...
Renz, Erik; Hackney, Madeleine; Hall, Courtney
2016-01-01
Intraocular lenses (IOLs) provide distance and near refraction and are becoming the standard for cataract surgery. Multifocal glasses increase variability of toe clearance in older adults navigating stairs and increase fall risk; however, little is known about the biomechanics of stair navigation in individuals with multifocal IOLs. This study compared clearance while ascending and descending stairs in individuals with monofocal versus multifocal IOLs. Eight participants with multifocal IOLs (4 men, 4 women; mean age = 66.5 yr, standard deviation [SD] = 6.26) and fifteen male participants with monofocal IOLs (mean age = 69.9 yr, SD = 6.9) underwent vision and mobility testing. Motion analysis recorded kinematic and custom software-calculated clearances in three-dimensional space. No significant differences were found between groups on minimum clearance or variability. Clearance differed for ascending versus descending stairs: the first step onto the stair had the greatest toe clearance during ascent, whereas the final step to the floor had the greatest heel clearance during descent. This preliminary study indicates that multifocal IOLs have similar biomechanic characteristics to monofocal IOLs. Given that step characteristics are related to fall risk, we can tentatively speculate that multifocal IOLs may carry no additional fall risk.
Gatto, Cheryl L.; Broadie, Kendal
2011-01-01
Fragile X syndrome (FXS), caused by loss of fragile X mental retardation 1 (FMR1) gene function, is the most common heritable cause of intellectual disability and autism spectrum disorders. The FMR1 product (FMRP) is an RNA-binding protein best established to function in activity-dependent modulation of synaptic connections. In the Drosophila FXS disease model, loss of functionally-conserved dFMRP causes synaptic overgrowth and overelaboration in pigment dispersing factor (PDF) peptidergic neurons in the adult brain. Here, we identify a very different component of PDF neuron misregulation in dfmr1 mutants: the aberrant retention of normally developmentally-transient PDF tritocerebral (PDF-TRI) neurons. In wild-type animals, PDF-TRI neurons in the central brain undergo programmed cell death and complete, processive clearance within days of eclosion. In the absence of dFMRP, a defective apoptotic program leads to constitutive maintenance of these peptidergic neurons. We tested whether this apoptotic defect is circuit-specific by examining crustacean cardioactive peptide (CCAP) and bursicon circuits, which are similarly developmentally-transient and normally eliminated immediately post-eclosion. In dfmr1 null mutants, CCAP/bursicon neurons also exhibit significantly delayed clearance dynamics, but are subsequently eliminated from the nervous system, in contrast to the fully persistent PDF-TRI neurons. Thus, the requirement of dFMRP for the retention of transitory peptidergic neurons shows evident circuit specificity. The novel defect of impaired apoptosis and aberrant neuron persistence in the Drosophila FXS model suggests an entirely new level of “pruning” dysfunction may contribute to the FXS disease state. PMID:21596027
ERIC Educational Resources Information Center
Wang, Yu-Hsiu; Baker, Megan
2013-01-01
This paper describes the automated copyright clearance process for electronic reserves materials by the electronic reserves staff at the Information and Library Services (ILS), at the University of Maryland University College (UMUC). Besides the standard practice to handle and post required course readings in digital format for UMUC's distance…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-07
.... Albert R. Spence, FAA Assistant Information Collection Clearance Officer, IT Enterprises Business... comments about our intention to request the Office of Management and Budget (OMB) approval to renew an... requires that training centers maintain records for a period of one year to show trainee qualifications for...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... postsecondary students in basic and applied research in STEM. If NSF must follow the normal OIRA clearance... request will assure continuation of the collection of information on student participants in the Research... undergraduate research experiences, NSF will have no other means to consistently document the number and...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-21
... DEPARTMENT OF THE INTERIOR National Park Service 60-Day Notice of Intention To Request Clearance...; National Park Service. ACTION: Notice and request for comments. SUMMARY: Under the provisions of the... Requirements, the National Park Service invites public comments on an extension of a currently approved...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strait, R.S.; Wagner, E.E.
1994-07-01
The US Department of Energy (DOE) Office of Safeguards and Security initiated the DOE Integrated Security System / Electronic Transfer (DISS/ET) for the purpose of reducing the time required to process security clearance requests. DISS/ET will be an integrated system using electronic commerce technologies for the collection and processing of personnel security clearance data, and its transfer between DOE local security clearance offices, DOE Operations Offices, and the Office of Personnel Management. The system will use electronic forms to collect clearance applicant data. The forms data will be combined with electronic fingerprint images and packaged in a secure encrypted electronicmore » mail envelope for transmission across the Internet. Information provided by the applicant will be authenticated using digital signatures. All processing will be done electronically.« less
Navier-Stokes analysis of radial turbine rotor performance
NASA Technical Reports Server (NTRS)
Larosiliere, L. M.
1993-01-01
An analysis of flow through a radial turbine rotor using the three-dimensional, thin-layer Navier-Stokes code RVC3D is described. The rotor is a solid version of an air-cooled metallic radial turbine having thick trailing edges, shroud clearance, and scalloped-backface clearance. Results are presented at the nominal operating condition using both a zero-clearance model and a model simulating the effects of the shroud and scalloped-backface clearance flows. A comparison with the available test data is made and details of the internal flow physics are discussed, allowing a better understanding of the complex flow distribution within the rotor.
A model of clearance rate regulation in mussels
NASA Astrophysics Data System (ADS)
Fréchette, Marcel
2012-10-01
Clearance rate regulation has been modelled as an instantaneous response to food availability, independent of the internal state of the animals. This view is incompatible with latent effects during ontogeny and phenotypic flexibility in clearance rate. Internal-state regulation of clearance rate is required to account for these patterns. Here I develop a model of internal-state based regulation of clearance rate. External factors such as suspended sediments are included in the model. To assess the relative merits of instantaneous regulation and internal-state regulation, I modelled blue mussel clearance rate and growth using a DEB model. In the usual standard feeding module, feeding is governed by a Holling's Type II response to food concentration. In the internal-state feeding module, gill ciliary activity and thus clearance rate are driven by internal reserve level. Factors such as suspended sediments were not included in the simulations. The two feeding modules were compared on the basis of their ability to capture the impact of latent effects, of environmental heterogeneity in food abundance and of physiological flexibility on clearance rate and individual growth. The Holling feeding module was unable to capture the effect of any of these sources of variability. In contrast, the internal-state feeding module did so without any modification or ad hoc calibration. Latent effects, however, appeared transient. With simple annual variability in temperature and food concentration, the relationship between clearance rate and food availability predicted by the internal-state feeding module was quite similar to that observed in Norwegian fjords. I conclude that in contrast with the usual Holling feeding module, internal-state regulation of clearance rate is consistent with well-documented growth and clearance rate patterns.
Interstitial fluid drainage is impaired in ischemic stroke and Alzheimer’s disease mouse models
Arbel-Ornath, Michal; Hudry, Eloise; Eikermann-Haerter, Katharina; Hou, Steven; Gregory, Julia L.; Zhao, Lingzhi; Betensky, Rebecca A.; Frosch, Matthew P.; Greenberg, Steven M.; Bacskai, Brian J.
2013-01-01
The interstitial fluid (ISF) drainage pathway has been hypothesized to underlie the clearance of solutes and metabolites from the brain. Previous work has implicated the perivascular spaces along arteries as the likely route for ISF clearance, however it has never been demonstrated directly. The accumulation of amyloid β (Aβ) peptides in brain parenchyma is one of the pathological hallmarks of Alzheimer disease (AD), and it is likely related to an imbalance between production and clearance of the peptide. Aβ drainage along perivascular spaces has been postulated to be one of the mechanisms that mediates the peptide clearance from the brain. We therefore devised a novel method to visualize solute clearance in real time in the living mouse brain using laser guided bolus dye injections and multiphoton imaging. This methodology allows high spatial and temporal resolution and revealed the kinetics of ISF clearance. We found that the ISF drains along perivascular spaces of arteries and capillaries but not veins, and its clearance exhibits a bi-exponential profile. ISF drainage requires a functional vasculature, as solute clearance decreased when perfusion was impaired. In addition, reduced solute clearance was observed in transgenic mice with significant vascular amyloid deposition; we suggest the existence of a feed-forward mechanism, by which amyloid deposition promotes further amyloid deposition. This important finding provides a mechanistic link between cerebrovascular disease and Alzheimer disease and suggests that facilitation of Aβ clearance along the perivascular pathway should be considered as a new target for therapeutic approaches to AD and CAA. PMID:23818064
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-20
... provide annual Management Information System testing information, and to communicate with entities subject... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Anti-Drug Program...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-24
... provide annual Management Information System testing information, and to communicate with entities subject... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Anti-Drug Program...
CYP2C9 polymorphisms and phenytoin metabolism: implications for adverse effects.
Franco, Valentina; Perucca, Emilio
2015-01-01
Phenytoin, a widely prescribed old-generation antiepileptic drug, requires careful individualization of dosage to compensate for its prominent pharmacokinetic variability. This article reviews the contribution of genetic polymorphisms affecting the activity of CYP2C9, the main enzyme responsible for phenytoin metabolism, to the variation in phenytoin clearance and susceptibility to adverse effects. Comprehensive and critical review of available evidence concerning the influence of CYP2C9 genetic polymorphism on phenytoin pharmacokinetic and safety profile. There is extensive evidence that CYP2C9 polymorphisms are an important determinant of the rate of phenytoin metabolism, although other factors including expression of other enzymes such as CYP2C19 and the influence of drug interactions, physiological and disease-related factors may also play a role. Patients carrying CYP2C9 genotypes associated with reduced phenytoin clearance are at greater risk of developing CNS adverse effects as well as serious cutaneous adverse reactions when given usual dosages of phenytoin. The clinical value and cost-effectiveness of CYP2C9 genotyping in improving the safety of phenytoin therapy, however, have not been clearly established and require formal testing in well-designed prospective studies.
SSME seal test program: Test results for smooth, hole-pattern and helically-grooved stators
NASA Technical Reports Server (NTRS)
Childs, Dara W.
1987-01-01
All of the listed seals were tested in a liquid Halon test facility at high Reynolds numbers. In addition, a helically-grooved-stator seal was tested in an air seal facility. An analysis of the test results with comparisons to theoretical predictions supports the following conclusions: (1) For small seals, the Hirs' friction-factor model is more restricted than had been thought; (2) For smooth seals, predictions of stiffness and damping improve markedly as the radical clearance is reduced; (3) Friction-factor data for hole-pattern-seal stators frequently deviates from the Hirs model; (4) Predictions of stiffness and damping coefficients for hole-pattern-stator seals is generally reasonable; (5) Tests for the hole-pattern stators at reduced clearances show no clear optimum for hole-pattern seals with respect to either hole-area ratio or hole depth to minimum clearance ratios; (6) Tests of these hole-pattern stators show no significant advantage in net damping over smooth seals; (7) Tests of helically-grooved seal stators in Halon show reasonable agreement between theory and prediction for leakage and direct stiffness but poor agreement for the net damping coefficient.
Nichols, John; Fay, Kellie; Bernhard, Mary Jo; Bischof, Ina; Davis, John; Halder, Marlies; Hu, Jing; Johanning, Karla; Laue, Heike; Nabb, Diane; Schlechtriem, Christian; Segner, Helmut; Swintek, Joe; Weeks, John; Embry, Michelle
2018-05-14
In vitro assays are widely employed to obtain intrinsic clearance estimates used in toxicokinetic modeling efforts. However, the reliability of these methods is seldom reported. Here we describe the results of an international ring trial designed to evaluate two in vitro assays used to measure intrinsic clearance in rainbow trout. An important application of these assays is to predict the effect of biotransformation on chemical bioaccumulation. Six laboratories performed substrate depletion experiments with cyclohexyl salicylate, fenthion, 4-n-nonylphenol, deltamethrin, methoxychlor, and pyrene using cryopreserved hepatocytes and liver S9 fractions from trout. Variability within and among laboratories was characterized as the percent coefficient of variation (CV) in measured in vitro intrinsic clearance rates (CLIN VITRO, INT; ml/h/mg protein or 106 cells) for each chemical and test system. Mean intra-laboratory CVs for each test chemical averaged 18.9% for hepatocytes and 14.1% for S9 fractions, while inter-laboratory CVs (all chemicals and all tests) averaged 30.1% for hepatocytes and 22.4% for S9 fractions. When CLIN VITRO, INT values were extrapolated to in vivo intrinsic clearance estimates (CLIN VIVO,INT; L/d/kg fish), both assays yielded similar levels of activity (< 4-fold difference for all chemicals). Hepatic clearance rates (CLH; L/d/kg fish) calculated using data from both assays exhibited even better agreement. These findings show that both assays are highly reliable and suggest that either may be used to inform chemical bioaccumulation assessments for fish. This study highlights several issues related to the demonstration of assay reliability and may provide a template for evaluating other in vitro biotransformation assays.
Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.
de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry
2017-09-01
Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Dynamic alteration in splenic function during acute falciparum malaria
DOE Office of Scientific and Technical Information (OSTI.GOV)
Looareesuwan, S.; Ho, M.; Wattanagoon, Y.
Plasmodium-infected erythrocytes lose their normal deformability and become susceptible to splenic filtration. In animal models, this is one mechanism of antimalarial defense. To assess the effect of acute falciparum malaria on splenic filtration, we measured the clearance of heated /sup 51/Cr-labeled autologous erythrocytes in 25 patients with acute falciparum malaria and in 10 uninfected controls. Two groups of patients could be distinguished. Sixteen patients had splenomegaly, markedly accelerated clearance of the labeled erythrocytes (clearance half-time, 8.4 +/- 4.4 minutes (mean +/- SD) vs. 62.5 +/- 36.5 minutes in controls; P less than 0.001), and a lower mean hematocrit than didmore » the patients without splenomegaly (P less than 0.001). In the nine patients without splenomegaly, clearance was normal. After institution of antimalarial chemotherapy, however, the clearance in this group accelerated to supernormal rates similar to those in the patients with splenomegaly, but without the development of detectable splenomegaly. Clearance was not significantly altered by treatment in the group with splenomegaly. Six weeks later, normal clearance rates were reestablished in most patients in both groups. We conclude that splenic clearance of labeled erythrocytes is enhanced in patients with malaria if splenomegaly is present and is enhanced only after treatment if splenomegaly is absent. Whether this enhanced splenic function applies to parasite-infected erythrocytes in patients with malaria and has any clinical benefit will require further studies.« less
Petitcollin, Antoine; Leuret, Oriane; Tron, Camille; Lemaitre, Florian; Verdier, Marie-Clémence; Paintaud, Gilles; Bouguen, Guillaume; Willot, Stéphanie; Bellissant, Eric; Ternant, David
2018-05-18
Antidrug antibodies (ADAs) dramatically increase infliximab clearance and are responsible for underexposure to the drug, leading to treatment failure. This pilot study aimed at developing a population pharmacokinetic model to detect and describe an early increase in infliximab clearance due to ADA. Twenty children with Crohn's disease (CD) were followed for 1 year or until treatment failure. Infliximab trough concentration, ADA, C-reactive protein (CRP), and Paediatric Crohn's Disease Activity Index (PCDAI) were recorded at each visit. A time-varying clearance population pharmacokinetic model was built to detect and describe an increase in infliximab clearance, independent from ADA testing. Factors associated with clearance variation and the relationships between infliximab concentrations, clearance variation, and clinical response were investigated. The model detected important increases in clearance in 4 patients. These patients had suboptimal early response, with higher mean PCDAI (P = 0.0086) and CRP (P = 0.028) compared with other patients. Two of them had detectable ADA. Clearance increase as described by the model and lower infliximab trough concentration at week 2 were associated with poorer outcomes in a multivariate Cox model (P = 0.001 and P = 0.0048, respectively). Being able to detect an increase in infliximab clearance, this model could allow the early detection of immunization to infliximab and therefore could help with dose adjustment in patients with CD. Moreover, the results suggest that clearance variations could be used as a predictive marker of clinical response. These findings need to be confirmed in a larger cohort, however, and predictive factors of clearance increase have to be investigated.
Jaeger, Laura B; Dohgu, Shinya; Hwang, Mark C; Farr, Susan A; Murphy, M Paul; Fleegal-DeMotta, Melissa A; Lynch, Jessica L; Robinson, Sandra M; Niehoff, Michael L; Johnson, Steven N; Kumar, Vijaya B; Banks, William A
2009-01-01
Decreased clearance is the main reason amyloid-beta protein (Abeta) is increased in the brains of patients with Alzheimer's disease (AD). The neurovascular hypothesis states that this decreased clearance is caused by impairment of low density lipoprotein receptor related protein-1 (LRP-1), the major brain-to-blood transporter of Abeta at the blood-brain barrier (BBB). As deletion of the LRP-1 gene is a lethal mutation, we tested the neurovascular hypothesis by developing a cocktail of phosphorothioate antisenses directed against LRP-1 mRNA. We found these antisenses in comparison to random antisense selectively decreased LRP-1 expression, reduced BBB clearance of Abeta42, increased brain levels of Abeta42, and impaired learning ability and recognition memory in mice. These results support dysfunction of LRP-1 at the BBB as a mechanism by which brain levels of Abeta could increase and AD would be promoted.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-05
... requires, among other things, that ICC accept or reject trades submitted for clearance that are executed... other things, that ICC accept or reject trades submitted for clearance that are not executed... the Commission's Internet comment form ( http://www.sec.gov/rules/sro.shtml ); or Send an email to...
Fluoride Penetration and Clearance Are Higher in Exopolysaccharide-Containing Bacterial Pellets.
Spinola, Manuela S; Nóbrega, Diego Figueiredo; Del Bel Cury, Altair Antoninha; Ricomini Filho, Antonio Pedro; Cury, Jaime Aparecido; Tenuta, Livia Maria Andaló
2018-06-06
Extracellular polysaccharides (EPS) could increase the penetration of fluoride through dental biofilm, reducing its cariogenicity. We measured the concentration of fluoride in EPS-containing (EPS+) or not-containing (EPS-) Streptococcus mutans bacterial pellets resembling test biofilms, before and up to 60 min after a 0.05% NaF rinse in situ. Fluoride penetration and clearance were higher in EPS+ bacterial pellets. The data suggest that EPS enhances fluoride penetration, but also accelerates fluoride clearance from dental biofilms. © 2018 S. Karger AG, Basel.
Tear clearance implications for ocular surface health.
de Paiva, Cintia Sade; Pflugfelder, Stephen C
2004-03-01
Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.
NASA Technical Reports Server (NTRS)
Foyle, David C.; Hooey, Becky L.; Bakowski, Deborah L.
2013-01-01
The results offour piloted medium-fidelity simulations investigating flight deck surface trajectory-based operations (STBO) will be reviewed. In these flight deck STBO simulations, commercial transport pilots were given taxi clearances with time and/or speed components and required to taxi to the departing runway or an intermediate traffic intersection. Under a variety of concept of operations (ConOps) and flight deck information conditions, pilots' ability to taxi in compliance with the required time of arrival (RTA) at the designated airport location was measured. ConOps and flight deck information conditions explored included: Availability of taxi clearance speed and elapsed time information; Intermediate RTAs at intermediate time constraint points (e.g., intersection traffic flow points); STBO taxi clearances via ATC voice speed commands or datal ink; and, Availability of flight deck display algorithms to reduce STBO RTA error. Flight Deck Implications. Pilot RTA conformance for STBO clearances, in the form of ATC taxi clearances with associated speed requirements, was found to be relatively poor, unless the pilot is required to follow a precise speed and acceleration/deceleration profile. However, following such a precise speed profile results in inordinate head-down tracking of current ground speed, leading to potentially unsafe operations. Mitigating these results, and providing good taxi RTA performance without the associated safety issues, is a flight deck avionics or electronic flight bag (EFB) solution. Such a solution enables pilots to meet the taxi route RTA without moment-by-moment tracking of ground speed. An avionics or EFB "error-nulling" algorithm allows the pilot to view the STBO information when the pilot determines it is necessary and when workload alloys, thus enabling the pilot to spread his/her attention appropriately and strategically on aircraft separation airport navigation, and the many other flight deck tasks concurrently required. Surface Traffic Management (STM) System Implications. The data indicate a number of implications regarding specific parameters for ATC/STM algorithm development. Pilots have a tendency to arrive at RTA points early with slow required speeds, on time for moderate speeds, and late with faster required speeds. This implies that ATC/STM algorithms should operate with middle-range speeds, similar to that of non-STBO taxi performance. Route length has a related effect: Long taxi routes increase the earliness with slow speeds and the lateness with faster speeds. This is likely due to the" open-loop" nature of the task in which the speed error compounds over a longer time with longer routes. Results showed that this may be mitigated by imposing a small number oftime constraint points each with their own RTAs effectively tuming a long route into a series of shorter routes - and thus improving RTA performance. STBO ConOps Implications. Most important is the impact that these data have for NextGen STM system ConOps development. The results of these experiments imply that it is not reasonable to expect pilots to taxi under a "Full STBO" ConOps in which pilots are expected to be at a predictable (x,y) airport location for every time (t). An STBO ConOps with a small number of intermediate time constraint points and the departing runway, however, is feasible, but only with flight deck equipage enabling the use of a display similar to the "error-nulling algorithm/display" tested.
Maringer, F J; Suráň, J; Kovář, P; Chauvenet, B; Peyres, V; García-Toraño, E; Cozzella, M L; De Felice, P; Vodenik, B; Hult, M; Rosengård, U; Merimaa, M; Szücs, L; Jeffery, C; Dean, J C J; Tymiński, Z; Arnold, D; Hinca, R; Mirescu, G
2013-11-01
In 2011 the joint research project Metrology for Radioactive Waste Management (MetroRWM)(1) of the European Metrology Research Programme (EMRP) started with a total duration of three years. Within this project, new metrological resources for the assessment of radioactive waste, including their calibration with new reference materials traceable to national standards will be developed. This paper gives a review on national, European and international strategies as basis for science-based metrological requirements in clearance and acceptance of radioactive waste. © 2013 Elsevier Ltd. All rights reserved.
Shape memory alloy adaptive control of gas turbine engine compressor blade tip clearance
NASA Astrophysics Data System (ADS)
Schetky, Lawrence M.; Steinetz, Bruce M.
1998-06-01
The ambient air ingested through the inlet of a gas turbine is first compressed by an axial compressor followed by further compression in a centrifugal compressor and then fed into the combustion chamber where ignition and expansion take place to produce the engine thrust. The axial compressor typically has five or more stages which consist of revolving blades and stators and the overall performance of the turbine is strongly affected by the compressor efficiency. When the turbine is turned on, to accommodate the rapid initial increase in the compressor blade length due to centrifugal force, the cold turbine has a built in clearance between the turbine blade tip and the casing. As the turbine reached its operating temperature there is a further increase in the blade length due to thermal expansion and, at the same time, the diameter of the casing increases. The net result is that when these various components have reached their equilibrium temperatures, the initial cold build clearance is reduced, but there remains a residual clearance. The magnitude of this clearance has a direct effect on the compressor efficiency and can be stated as: Δη/Δ CLR equals 0.5 where η is efficiency and CLR is the tip clearance. The concept of adaptive tip clearance control is based on the ability of a shape memory alloy ring to shrink to a predetermined diameter when heated to the temperature of a particular stage, and thus reducing the tip clearance. The ring is fabricated from a CuAlNi shape memory alloy and is mounted in the casing so as to be coaxial with the rotating blades of the particular stage. When cold, the ring dimensions are such as to provide the required cold build clearance, but when at operating temperature the reduced diameter creates a very small tip clearance. The clearance provided by this concept is much smaller than the clearance normally obtained for a turbine of the size being studied.
Dukas, L; Schacht, E; Runge, M
2010-07-01
We assessed in a cross-sectional study in elderly men and women with osteoporosis, the association between the creatinine clearance (CrCl) and the performance in different balance and muscle power and function tests and found that a decreasing creatinine clearance was significantly associated with lower balance and muscle power. To determine if a creatinine clearance of <65 ml/min is significantly associated with decreasing muscle power and balance and an increased risk for falls and fractures. We assessed in a cross-sectional-study in 1781 German osteoporotic patients, the association between the CrCl, the physical performance, and the number of falls and fractures. Controlling for age, gender, BMI, and osteoporosis treatment (fracture analysis only), a decreasing CrCl was associated with lower physical performance in the timed-up-and-go test (corr -0.2337, P < 0.0001), chair-rising test (corr -0.1706, P < 0.001), and tandem-stand test (corr 0.2193, P < 0.0001), and a CrCl of <65 ml/min was associated with a significantly higher risk for falls (47.7% vs. 36.2%, P = 0.0008) and fall-related fractures (33.1% vs. 22.9%, P = 0.0003) compared with a CrCl of >or=65 ml/min. In this study, we found a significant gender-independent correlation between decreasing CrCl and lower performance in balance and muscle power tests. Reduced muscle power and balance may therefore be involved in the low creatinine clearance associated increased risk for falls and fall-related fractures. Furthermore, we found that a CrCl <65 ml/min., independent from the performance in muscle power, muscle function, and balance tests, is a significant risk factor for falls and fractures.
Dutta, Arindam; Kundabala, Mala
2014-01-01
Objective: The anti-microbial efficacy of 2.5% sodium hypochlorite (SHC) and 0.2% chlorhexidine gluconate were compared with an experimental irrigant formulated from the Neem tree, Azadirachta indica A. Juss. Materials and Methods: A sample of 36 single rooted anterior teeth with periapical radiolucency and absence of response to vitality tests that required root canal treatment were selected for this study. The test irrigants and their combinations were assigned to five different groups and saline served as the control. Access cavities were prepared using an aseptic technique and samples collected for both anaerobic culture and Gram stained smears, followed by irrigation and sample collection again. The number of organisms were expressed in colony forming units/ml after 72 h of incubation; the smears were analyzed for their microbial loads and tissue clearance and assessed as per defined criteria. Results: Our results found the maximum reduction in microbial loads, when analyzed by culture method, with a combination of SHC and the experimental neem irrigant. Maximum tissue clearance on the Gram Stained smears was also found with the same combination. Conclusion: Neem irrigant has anti-microbial efficacy and can be considered for endodontic use. PMID:24778508
[Conservative calibration of a clearance monitor system for waste material from nuclear medicine].
Wanke, Carsten; Geworski, Lilli
2014-09-01
Clearance monitor systems are used for gross gamma measurements of waste potentially contaminated with radioactivity. These measurements are to make sure that legal requirements, e.g. clearance criteria according to the german radiation protection ordinance, are met. This means that measurement results may overestimate, but must not underestimate the true values. This paper describes a pragmatic way using a calibrated Cs-137 point source to generate a conservative calibration for the clearance monitor system used in the Medizinische Hochschule Hannover (MHH). The most important nuclides used in nuclear medicine are considered. The measurement result reliably overestimates the true value of the activity present in the waste. The calibration is compliant with the demands for conservativity and traceability to national standards. Copyright © 2014. Published by Elsevier GmbH.
NASA Technical Reports Server (NTRS)
Stromberg, W. J.
1981-01-01
An engine was specially prepared with extensive instrumentation to monitor performance, case temperatures, and clearance changes. A special loading device was used to apply known loads on the engine by the use of cables placed around the flight inlet. These loads simulated the estimated aerodynamic pressure distributions that occur on the inlet in various segments of a typical airplane flight. Test results indicate that the engine lost 1.3 percent in take-off thrust specific fuel consumption (TSFC) during the course of the test effort. Permanent clearance changes due to the loads accounted for 1.1 percent; increase in low pressure compressor airfoil roughness and thermal distortion in the high pressure turbine accounted for 0.2 percent. Pretest predicted performance loss due to clearance changes was 0.9 percent in TSFC. Therefore, the agreement between measurement and prediction is considered to be excellent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, K.; Collins, D.C.; Preedy, J.R.K.
Specific RIAs requiring ether extraction only were established for estrone and 17..beta..-estradiol both in plasma and in urine from the nonpregnant female. These assays were used to measure the renal clearance rates of estrone and of 17..beta..-estradiol in eight ambulatory women in the follicular and in the luteal phases of the menstrual cycle. The mean (+-SE) for the renal clearance rate of estrone was 0.71 +- 0.058 ml/min in the follicular phase and 1.26 +- 0.35 ml/min in the luteal phase. The mean (+-SE) renal clearance rate of 17..beta..-estradiol was 0.44 +- 0.055 ml/min in the follicular phase and 0.29more » +- 0.043 ml/min in the luteal phase. There was no significant difference in the renal clearance rates of either estrone or of 17..beta..-estradiol between the follicular and luteal phases of the cycle. The renal clearances of estrone and 17..beta..-estradiol were highly correlated (r = 0.84; P < 0.01). The renal clearance rate of estrone was significantly greater than that of 17..beta..-estradiol in both phases of the cycle (P < 0.01).« less
21 CFR 606.100 - Standard operating procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... or hepatitis C virus (HCV) infection when tested under § 610.40 of this chapter, or when a blood... viral clearance procedures; (iii) To notify consignees to quarantine in-date blood and blood components... are manufactured using validated viral clearance procedures; (iv) To determine the suitability for...
The CF6 engine performance improvement
NASA Technical Reports Server (NTRS)
Fasching, W. A.
1982-01-01
As part of the NASA-sponsored Engine Component Improvement (ECI) Program, a feasibility analysis of performance improvement and retention concepts for the CF6-6 and CF6-50 engines was conducted and seven concepts were identified for development and ground testing: new fan, new front mount, high pressure turbine aerodynamic performance improvement, high pressure turbine roundness, high pressure turbine active clearance control, low pressure turbine active clearance control, and short core exhaust nozzle. The development work and ground testing are summarized, and the major test results and an enomic analysis for each concept are presented.
2012-01-01
Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 hours and then daily in 484 patients. AKI was defined either as > 50% increase in plasma creatinine from baseline, or > 33.3% decrease in creatinine clearance. The diagnostic and predictive performance of the two AKI definitions were compared. Results Creatinine clearance decrease diagnosed AKI in 24% of those not diagnosed by plasma creatinine increase on entry. These patients entered the ICU sooner after insult than those diagnosed with AKI by plasma creatinine elevation (P = 0.0041). Mortality and dialysis requirement increased with the change in creatinine clearance-acute kidney injury severity class (P = 0.0021). Amongst patients with plasma creatinine < 1.24 mg/dl on entry, creatinine clearance improved the prediction of AKI considerably (Net Reclassification Improvement 83%, Integrated Discrimination Improvement 0.29). On-entry, creatinine clearance associated with AKI severity and duration (P < 0.0001) predicted dialysis need (area under the curve: 0.75) and death (0.61). A > 33.3% decrease in creatinine clearance over the first 12 hours was associated with a 2.0-fold increased relative risk of dialysis or death. Conclusions Repeated 4-hour creatinine clearance measurements in critically ill patients allow earlier detection of AKI, as well as progression and recovery compared to plasma creatinine. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN012606000032550. PMID:22713519
CF6 jet engine diagnostics program. High pressure turbine roundness/clearance investigation
NASA Technical Reports Server (NTRS)
Howard, W. D.; Fasching, W. A.
1982-01-01
The effects of high pressure turbine clearance changes on engine and module performance was evaluated in addition to the measurement of CF6-50C high pressure turbine Stage 1 tip clearance and stator out-of-roundness during steady-state and transient operation. The results indicated a good correlation of the analytical model of round engine clearance response with measured data. The stator out-of-roundness measurements verified that the analytical technique for predicting the distortion effects of mechanical loads is accurate, whereas the technique for calculating the effects of certain circumferential thermal gradients requires some modifications. A potential for improvement in roundness was established in the order of 0.38 mm (0.015 in.), equivalent to 0.86 percent turbine efficiency which translates to a cruise SFC improvement of 0.36 percent. The HP turbine Stage 1 tip clearance performance derivative was established as 0.44 mm (17 mils) per percent of turbine efficiency at take-off power, somewhat smaller, therefore, more sensitive than predicted from previous investigations.
Modeling the accumulation of degradable polymer drug carriers in the brain.
Bolwerk, Celine; Govers, Larissa P M W D; Knol, Hanna; Oostendorp, Thom F; Brock, Roland
2018-05-11
The blood brain barrier (BBB) limits the access of drugs to the brain. Intensive research is being conducted on the development of nanoparticulate drug carriers that mediate transfer across the BBB. A question that has been neglected so far is the potential accumulation of the carrier in the brain upon long-term exposure. Here, we address this question by implementing a kinetic model to relate drug loading, required concentration of drug in the brain and drug clearance to the degradation half-life of the carrier. As a test case with clinical relevance we chose poly-lactic-co-glycolic-acid (PLGA) as a carrier material and a chemotherapeutic for which the required parameters could be recovered from literature. For methotrexate with a drug load of 8.5 %, a required concentration of free drug of 1 µM, a release from PLGA of 6 hours, a drug clearance from the brain of 3 hours and a half-life of polymer degradation of 28 days, a steady state accumulation of 1.3 g polymer would be reached in the brain (1.5L) after 7 months. While this number is surprisingly small, further physiological research is warranted to assess to which degree this will be in a tolerable range. Insert abstract text here. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tear clearance and ocular symptoms in patients treated with preservative-free prostaglandins.
Giménez-Gómez, R; García-Catalán, M R; Gallardo-Galera, J M
2013-03-01
To assess the effects on dry eye symptoms and tear dynamics of switching from a prostaglandin with a preservative to a preservative-free prostaglandin. Fourteen patients (N=28 eyes) with open-angle glaucoma and dry eye symptons, treated with preserved latanoprost, travoprost or bimatoprost were included in this uncontrolled prospective study. Ocular symptoms were analysed using a validated ocular surface disease questionnaire and ocular signs were assessed with tear clearance, Schirmer and tear function index test (TFI=Schirmer/clearance). Patients were assigned to preservative-free tafluprost treatment, and measurements were repeated 4 weeks after change of medication. Wilcoxon test and Spearman correlation coefficient were used in the statistical analysis. No statistically significant difference in intraocular pressure (IOP) was observed after switching to tafluprost. Mean IOP at baseline was 20.4 mmHg (SD2.2) and after 4 weeks 19.9 mmHg (SD2.6), (P>.05). The mean questionnaire score significantly decreased from 9.7 (SD3.7) at baseline to 5.4 (SD2.7) after one month (P<.001). No significant differences in tear clearance, Schirmer or TFI were found (P>.05). At baseline, tear clearance=0.13 (SD0.07), Schirmer=10.7 mm (SD6) and TFI=80 (48-156). After 4 weeks, tear clearance=0.1(SD0.07), Schirmer=9.5 mm (3.9) and TFI=104 (48-216). A significant association between questionnaire score and tear clearance after 4 weeks was observed (Spearman coefficient=0.62; P=.014). Switching from preservative prostaglandin with a preservative to preservative-free tafluprost treatment improves dry eye symptoms and suggests an improvement in TFI. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Utiyama, Daniela Mitiyo Odagiri; Yoshida, Carolina Tieko; Goto, Danielle Miyuki; de Santana Carvalho, Tômas; de Paula Santos, Ubiratan; Koczulla, Andreas Rembert; Saldiva, Paulo Hilário Nascimento; Nakagawa, Naomi Kondo
2016-01-01
OBJECTIVE: The aim of the present study was to assess nasal mucociliary clearance, mucus properties and inflammation in smokers and subjects enrolled in a Smoking Cessation Program (referred to as quitters). METHOD: A total of 33 subjects with a median (IQR) smoking history of 34 (20-58) pack years were examined for nasal mucociliary clearance using a saccharine transit test, mucus properties using contact angle and sneeze clearability tests, and quantification of inflammatory and epithelial cells, IL-6 and IL-8 concentrations in nasal lavage fluid. Twenty quitters (mean age: 51 years, 9 male) were assessed at baseline, 1 month, 3 months and 12 months after smoking cessation, and 13 smokers (mean age: 52 years, 6 male) were assessed at baseline and after 12 months. Clinicaltrials.gov: NCT02136550. RESULTS: Smokers and quitters showed similar demographic characteristics and morbidities. At baseline, all subjects showed impaired nasal mucociliary clearance (mean 17.6 min), although 63% and 85% of the quitters demonstrated significant nasal mucociliary clearance improvement at 1 month and 12 months, respectively. At 12 months, quitters also showed mucus sneeze clearability improvement (∼26%), an increased number of macrophages (2-fold) and no changes in mucus contact angle or cytokine concentrations. CONCLUSION: This study showed that smoking cessation induced early improvements in nasal mucociliary clearance independent of mucus properties and inflammation. Changes in mucus properties were observed after only 12 months of smoking cessation. PMID:27438569
Broussard, Cheryl S; Goodman, Karen J; Phillips, Carl V; Smith, Mary Ann; Fischbach, Lori A; Day, R Sue; Aragaki, Corinne C
2009-08-01
Factors that determine persistence of untreated Helicobacter pylori (H. pylori) infection in childhood are not well understood. We estimated risk differences for the effect of incidental antibiotic exposure on the probability of a detected clearance at the next test after an initial detected H. pylori infection. The Pasitos Cohort Study (1998-2005) investigated predictors of H. pylori infection in children from El Paso, Texas, and Juarez, Mexico. Children were screened for infection at 6-month target intervals from 6 to 84 months of age, using the 13C-urea breath test corrected for body-size-dependent variation in CO2 production. Exposure was defined as courses of any systemic antibiotic (systemic) or those with anti-H. pylori action (HP-effective) reported for the interval between initial detected infection and next test. Binomial regression models included country of residence, mother's education, adequacy of prenatal care, age at infection, and interval between tests. Of 205 children with a test result and antibiotic data following a detected infection, the number of children who took > or =1 course in the interval between tests was 74 for systemic and 33 for HP-effective. The proportion testing negative at the next test was 66% for 0 courses, 72% for > or =1 systemic course, and 79% for > or =1 HP-effective course. Adjusted risk differences (95%CI) for apparent clearance, comparing > or =1 to 0 courses were 10% (1-20%) for systemic and 11% (0-21%) for HP-effective. Incidental antibiotic exposure appears to influence the duration of childhood H. pylori infection but seems to explain only a small portion of spontaneous clearance. Copyright 2009 John Wiley & Sons, Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
... DEPARTMENT OF TRANSPORTATION Office of the Secretary [Docket No. DOT-OST-2011-0057] Agency Information Collection Activities: Requests for Comments; Clearance of a Renewed Approval of Information Collection(s): Procedures for Transportation Workplace Drug and Alcohol Testing Programs AGENCY: Office of...
Sobolev, Boris; Levy, Adrian; Hayden, Robert; Kuramoto, Lisa
2006-01-01
Objective To determine whether the probability of undergoing coronary bypass surgery within a certain time was related to the number of patients on the wait list at registration for the operation in a publicly funded health system. Methods A prospective cohort study comparing waiting times among patients registered on wait lists at the hospitals delivering adult cardiac surgery. For each calendar week, the list size, the number of new registrations, and the number of direct admissions immediately after angiography characterized the demand for surgery. Results The length of delay in undergoing treatment was associated with list size at registration, with shorter times for shorter lists (log-rank test 1,198.3, p<.0001). When the list size at registration required clearance time over 1 week patients had 42 percent lower odds of undergoing surgery compared with lists with clearance time less than 1 week (odds ratio [OR] 0.58 percent, 95 percent, confidence interval [CI] 0.53–0.63), after adjustment for age, sex, comorbidity, period, and hospital. The weekly number of new registrations exceeding weekly service capacity had an independent effect toward longer service delays when the list size at registration required clearance time less than 1 week (OR 0.56 percent, 95 percent CI 0.45–0.71), but not for longer lists. Every time the operation was performed for a patient requiring surgery without registration on wait lists, the odds of surgery for listed patients were reduced by 6 percent (OR 0.94, CI 0.93–0.95). Conclusion For wait-listed patients, time to surgery depends on the list size at registration, the number of new registrations, as well as on the weekly number of patients who move immediately from angiography to coronary bypass surgery without being registered on a wait list. Hospital managers may use these findings to improve resource planning and to reduce uncertainty when providing advice on expected treatment delays. PMID:16430599
2007 NASA Seal/Secondary Air System Workshop. Volume 1
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M.; Hendricks, Robert C.; Delgado, Irebert
2008-01-01
The 2007 NASA Seal/Secondary Air System workshop covered the following topics: (i) Overview of NASA's new Orion project aimed at developing a new spacecraft that will fare astronauts to the International Space Station, the Moon, Mars, and beyond; (ii) Overview of NASA's fundamental aeronautics technology project; (iii) Overview of NASA Glenn s seal project aimed at developing advanced seals for NASA's turbomachinery, space, and reentry vehicle needs; (iv) Reviews of NASA prime contractor, vendor, and university advanced sealing concepts, test results, experimental facilities, and numerical predictions; and (v) Reviews of material development programs relevant to advanced seals development. Turbine engine studies have shown that reducing seal leakage as well as high-pressure turbine (HPT) blade tip clearances will reduce fuel burn, lower emissions, retain exhaust gas temperature margin, and increase range. Turbine seal development topics covered include a method for fast-acting HPT blade tip clearance control, noncontacting low-leakage seals, intershaft seals, and a review of engine seal performance requirements for current and future Army engine platforms.
Energy efficient engine. Low pressure turbine test hardware detailed design report
NASA Technical Reports Server (NTRS)
Cherry, D. G.; Gay, C. H.; Lenahan, D. T.
1982-01-01
The low pressure turbine for the energy efficient engine is a five-stage configuration with moderate aerodynamic loading incorporating advanced features of decambered airfoils and extended blade overlaps at platforms and shrouds. Mechanical integrity of 18,000 hours on flowpath components and 36,000 hours on all other components is achieved along with no aeromechanical instabilities within the steady-state operating range. Selection of a large number (156) of stage 4 blades, together with an increased stage 4 vane-to-blade gap, assists in achieving FAR 36 acoustic goals. Active clearance control (ACC) of gaps at blade tips and interstage seals is achieved by fan air cooling judiciously applied at responsive locations on the casing. This ACC system is a major improvement in preventing deterioration of the 0.0381 cm (0.015 in.) clearances required to meet the integrated-core/low-spool turbine efficiency goal of 91.1% and the light propulsion system efficiency goal of 91.7%.
2008 NASA Seal/Secondary Air System Workshop
NASA Technical Reports Server (NTRS)
Steinetz, Bruce M. (Editor); Hendricks, Robert C. (Editor); Delgado, Irebert R. (Editor)
2009-01-01
The 2008 NASA Seal/Secondary Air System Workshop covered the following topics: (i) Overview of NASA s new Orion project aimed at developing a new spacecraft that will fare astronauts to the International Space Station, the Moon, Mars, and beyond; (ii) Overview of NASA s fundamental aeronautics technology project; (iii) Overview of NASA Glenn s seal project aimed at developing advanced seals for NASA s turbomachinery, space, and reentry vehicle needs; (iv) Reviews of NASA prime contractor, vendor, and university advanced sealing concepts, test results, experimental facilities, and numerical predictions; and (v) Reviews of material development programs relevant to advanced seals development. Turbine engine studies have shown that reducing seal leakage as well as high-pressure turbine (HPT) blade tip clearances will reduce fuel burn, lower emissions, retain exhaust gas temperature margin, and increase range. Turbine seal development topics covered include a method for fast-acting HPT blade tip clearance control, noncontacting low-leakage seals, intershaft seals, and a review of engine seal performance requirements for current and future Army engine platforms.
Whirl measurements on leakage flows in turbomachine models
NASA Technical Reports Server (NTRS)
Addlesee, A. J.; Altiparmak, D.; Pan, S.
1994-01-01
The beneficial effects claimed for whirl control devices demonstrate that the dynamic behavior of rotors is influenced by the fluid whirl in shaft and balance drum seals. The present paper reports results from two series of experiments, the first on the factors affecting the whirl at the seal inlet, and the second on the variation of whirl velocity along the seal. In both cases the LDA measurement technique required the clearance between the fixed and rotating parts of the models to be substantially greater than occurs in real machines, but the results are indicative nevertheless. Experimental and theoretical results are given for the radial distribution of whirl velocity in the gap between impeller shroud and pump casing. Results of tests with modified stator surfaces are also shown. This work leads naturally into the second series of experiments where some preliminary measurements of velocity distribution in the clearance between a fixed stator and a rotating shaft are reported for a range of inlet whirl conditions.
Association of HPV infection and clearance with cervicovaginal immunology and the vaginal microbiota
Shannon, B; Yi, TJ; Perusini, S; Gajer, P; Ma, B; Humphrys, MS; Thomas-Pavanel, J; Chieza, L; Janakiram, P; Saunders, M; Tharao, W; Huibner, S; Shahabi, K; Ravel, J; Rebbapragada, A; Kaul, R
2016-01-01
Cervical human papillomavirus (HPV) infection may increase HIV risk. Since other genital infections enhance HIV susceptibility by inducing inflammation, we assessed the impact of HPV infection and clearance on genital immunology and the cervico-vaginal microbiome. Genital samples were collected from 65 women for HPV testing, immune studies and microbiota assessment; repeat HPV testing was performed after 6 months. All participants were HIV-uninfected and free of bacterial STIs. Cytobrush-derived T cell and dendritic cell subsets were assessed by multiparameter flow cytometry. Undiluted cervico-vaginal secretions were used to determine cytokine levels by multiplex ELISA, and to assess bacterial community composition and structure by 16S rRNA gene sequence analysis. Neither HPV infection nor clearance were associated with broad differences in cervical T cell subsets or cytokines, although HPV clearance was associated with increased Langerhans cells and HPV infection with elevated IP-10 and MIG. Individuals with HPV more frequently had a high diversity cervico-vaginal microbiome (community state type IV) and were less likely to have an L. gasseri predominant microbiome. In summary, HPV infection and/or subsequent clearance was not associated with inflammation or altered cervical T cell subsets, but associations with increased Langerhans cells and the composition of the vaginal microbiome warrant further exploration. PMID:28120845
Effect of the presence of dental plaque on oral sugar clearance and salivary pH: an in vivo study.
Pradhan, Debapriya; Jain, Deepak; Gulati, Amit; Kolhe, Swapnil J; Baad, Rajendra; Rao, B Sunil
2012-11-01
Fermentable carbohydrates and microorganisms in the plaque play a significant role in the pathogenesis of dental caries. Oral clearance of sugars and salivary pH is affected by the presence of plaque. This study was conducted to study the effect of the presence of plaque on the salivary clearance of sucrose and on salivary pH. The study design was of a randomized controlled parallel group clinical trial and included two groups: The control group and plaque group, as follows: Control group--subjects without plaque and plaque group--subjects with plaque. Salivary sucrose determination was done by using the anthrone technique. A digital pH meter estimated the salivary pH. The Student's t test and Mann-Whitney test was employed to compare the intergroup differences. Pearson's correlation coefficient was used for analysis. The salivary sucrose clearance time was increased by presence of plaque. The presence of plaque led to increased salivary sucrose concentrations and increased the salivary sucrose clearance time. The dental caries is the dynamic relationship among the dental plaque microbiota, dietary carbohydrates, saliva and cariogenic potential of the dental plaque. Caries occur preferentially in the dentition sites characterized by high exposure to carbohydrate and diminished salivary effect.
Tacrine is not an ideal probe drug for measuring CYP1A2 activity in vivo
Larsen, J T; Hansen, L L; Brøsen, K
1999-01-01
Aims The aim of the present study was to examine the CYP1A2 substrate tacrine as a possible alternative to caffeine for assessing CYP1A2 activity in vivo. Methods Eighteen, healthy, nonsmoking men participated. Each volunteer was tested by caffeine (200 mg orally), and caffeine metabolic ratios were calculated. Subsequently, on two occasions, separated by at least 4 weeks, each volunteer was tested with tacrine (40 mg orally). The apparent oral clearance, partial clearances and different metabolic ratios of tacrine were determined. Results The median oral clearances of tacrine in the two study periods were 1893 l h−1 (range: 736–3098) and 1890 l h−1 (range: 438–4175), respectively. The interindividual coefficient of variation was 42% and 49%, respectively. The intraindividual coefficients of variation ranged from 0.28% to 64% (median: 13%). In both study periods, the oral clearance of tacrine correlated with the caffeine urinary metabolic ratio. However, only modest magnitudes of correlation were observed (rs: 0.64–0.66, P < 0.01). No tacrine metabolic ratio correlating with the oral clearance of tacrine was found. Conclusion The applicability of tacrine as a probe drug for measuring CYP1A2 activity in vivo appears limited. PMID:10594467
Epitrochoid Power-Law Nozzle Rapid Prototype Build/Test Project (Briefing Charts)
2015-02-01
Production Approved for public release; distribution is unlimited. PA clearance # 15122. 4 Epitrochoid Power-Law Nozzle Build/Test Build on SpaceX ...Multiengine Approach SpaceX ) Approved for public release; distribution is unlimited. PA clearance # 15122. Engines: Merlin 1D on Falcon 9 v1.1 (Photo 5...to utilize features of high performance engines advances and the economies of scale of the multi-engine approach of SpaceX Falcon 9 – Rapid Prototype
NASA Technical Reports Server (NTRS)
Sallee, G. P.; Martin, R. L.
1980-01-01
The JT9D jet engine exhibits a TSFC loss of about 1 percent in the initial 50 flight cycles of a new engine. These early losses are caused by seal-wear induced opening of running clearances in the engine gas path. The causes of this seal wear have been identified as flight induced loads which deflect the engine cases and rotors, causing the rotating blades to rub against the seal surfaces, producing permanent clearance changes. The real level of flight loads encountered during airplane acceptance testing and revenue service and the engine's response in the dynamic flight environment were investigated. The feasibility of direct measurement of these flight loads and their effects by concurrent measurement of 747/JT9D propulsion system aerodynamic and inertia loads and the critical engine clearance and performance changes during 747 flight and ground operations was evaluated. A number of technical options were examined in relation to the total estimated program cost to facilitate selection of the most cost effective option. It is concluded that a flight test program meeting the overall objective of determining the levels of aerodynamic and inertia load levels to which the engine is exposed during the initial flight acceptance test and normal flight maneuvers is feasible and desirable. A specific recommended flight test program, based on the evaluation of cost effectiveness, is defined.
Tang, Yunhua; Han, Ming; Chen, Maogen; Wang, Xiaoping; Ji, Fei; Zhao, Qiang; Zhang, Zhiheng; Ju, Weiqiang; Wang, Dongping; Guo, Zhiyong; He, Xiaoshun
2017-11-01
Transplantation centers have given much attention to donor availability. However, no reliable quantitative methods have been employed to accurately assess graft quality before transplantation. Here, we report that the indocyanine green (ICG) clearance test is a valuable index for liver grafts. We performed the ICG clearance test on 90 brain-dead donors within 6 h before organ procurement between March 2015 and November 2016. We also analyzed the relationship between graft liver function and early graft survival after liver transplantation (LT). Our results suggest that the ICG retention rate at 15 min (ICGR15) of donors before procurement was independently associated with 3-month graft survival after LT. The best donor ICGR15 cutoff value was 11.0%/min, and we observed a significant increase in 3-month graft failure among patients with a donor ICGR15 above this value. On the other hand, a donor ICGR15 value of ≤ 11.0%/min could be used as an early assessment index of graft quality because it provides additional information to the transplant surgeon or organ procurement organization members who must maintain or improve organ function to adapt the LT. An ICG clearance test before liver procurement might be an effective quantitative method to predict graft availability and improve early graft prognosis after LT.
Woodley, Frederick W; Moore-Clingenpeel, Melissa; Machado, Rodrigo Strehl; Nemastil, Christopher J; Jadcherla, Sudarshan R; Hayes, Don; Kopp, Benjamin T; Kaul, Ajay; Di Lorenzo, Carlo; Mousa, Hayat
2017-09-01
Acid neutralization during chemical clearance is significantly prolonged in children with cystic fibrosis, compared to symptomatic children without cystic fibrosis. The absence of available reference values impeded identification of abnormal findings within individual patients with and without cystic fibrosis. The present study aimed to test the hypothesis that significantly more children with cystic fibrosis have acid neutralization durations during chemical clearance that fall outside the physiological range. Published reference value for acid neutralization duration during chemical clearance (determined using combined impedance/pH monitoring) was used to assess esophageal acid neutralization efficiency during chemical clearance in 16 children with cystic fibrosis (3 to <18 years) and 16 age-matched children without cystic fibrosis. Duration of acid neutralization during chemical clearance exceeded the upper end of the physiological range in 9 of 16 (56.3%) children with and in 3 of 16 (18.8%) children without cystic fibrosis ( p =0.0412). The likelihood ratio for duration indicated that children with cystic fibrosis are 2.1-times more likely to have abnormal acid neutralization during chemical clearance, and children with abnormal acid neutralization during chemical clearance are 1.5-times more likely to have cystic fibrosis. Significantly more (but not all) children with cystic fibrosis have abnormally prolonged esophageal clearance of acid. Children with cystic fibrosis are more likely to have abnormal acid neutralization during chemical clearance. Additional studies involving larger sample sizes are needed to address the importance of genotype, esophageal motility, composition and volume of saliva, and gastric acidity on acid neutralization efficiency in cystic fibrosis children.
Dagan, Amit; Dagan, Ovadia
2016-12-01
Early surgical correction of congenital heart malformations in neonates and small infants may be complicated by acute kidney injury (AKI), which is associated with higher morbidity and mortality rates, especially in patients who require dialysis. Glomerular filtration rate (GFR) is considered the best measurement of renal function which, in neonates and infants, is highly dependent on heart function. To determine whether measurements of creatinine clearance after open heart surgery in neonates and young infants can serve as an early indicator of surgical success or AKI. We conducted a prospective observational study in 19 neonates and small infants (body weight < 5 kg) scheduled for open heart surgery with cardiopulmonary bypass. Urine collection measurement of creatinine clearance and albumin excretion was performed before and during surgery and four times during 48 hours after surgery. Mean creatinine clearance was lowest during surgery (25.2 ± 4. ml/min/1.73 m2) and increased significantly in the first 16 hours post-surgery (45.7 ± 6.3 ml/min/1.73 m2). A similar pattern was noted for urine albumin which was highest during surgery (203 ± 31 µg/min) and lowest (93 ± 20 µg/min) 48 hours post-surgery. AKI occurred in four patients, and two patients even required dialysis. All six showed a decline in creatinine clearance and an increase in urine albumin between 8 and 16 hours post-surgery. In neonates and small infants undergoing open heart surgery, a significant improvement in creatinine clearance in the first 16 hours postoperatively is indicative of a good surgical outcome. This finding has important implications for the early evaluation and treatment of patients in the intensive care unit on the first day post-surgery.
Muszkat, Mordechai; Bialer, Omer; Blotnick, Simcha; Adar, Liat; Xie, Hong-Guang; Ufer, Mike; Cascorbi, Ingolf; Caraco, Yoseph
2010-02-01
Folic acid supplementation in patients with folic acid deficiency has been associated with increased clearance of phenytoin to its cytochrome P450 (CYP) 2C9-mediated metabolite, 5-(4'-hydroxyphenyl)-5-phenylhydantoin. The aim of this study was to determine whether folic acid supplementation increases the dosage requirement of the CYP2C9 substrate warfarin, and the formation clearance of the CYP2C9-mediated product, (S)-7-hydroxywarfarin. Patients aged >or=18 years with folic acid deficiency who were receiving long-term treatment with a stable dosage of warfarin were studied prospectively, before and 30 to 60 days after the initiation of supplementation with folic acid. Warfarin dosage and international normalized ratio (INR) were documented, and the formation clearance of (S)- and (R)-7-hydroxywarfarin and the oral clearance of (S)- and (R)-warfarin were determined. Twenty-four white patients (14 males; mean (SD) age, 55.0 [19.7] years; body mass index, 30.64 [6.8] kg/m(2)) were enrolled. Treatment with folic acid was associated with a significantly increased mean (SD) formation clearance of (S)-7-hydroxywarfarin (1.096 [0.816] vs 1.608 [1.302] mL/min; P = 0.048). Before folic acid supplementation, the mean (SD) warfarin dosage was 5.98 (2.12) mg/d, and the INR was 2.51 (0.55). During supplementation, the warfarin dosage was 6.17 (2.31) mg/d and the INR was 2.63 (0.65) (both, P = NS vs before supplementation). Folic acid supplementation was associated with significantly increased formation clearance of (S)-7-hydroxywarfarin. Changes in warfarin dosage requirements and INR were nonsignificant. Copyright 2010. Published by EM Inc USA.
Bush, Lisa; Brookshire, Robert; Roche, Breanna; Johnson, Amelia; Cole, Frederic; Karmy-Jones, Riyad; Long, William; Martin, Matthew J
2016-09-01
Current trauma guidelines dictate that the cervical spine should not be cleared in intoxicated patients, resulting in prolonged immobilization or additional imaging. Modern computed tomography (CT) technology may obviate this and allow for immediate clearance. To analyze cervical spine clearance practices and the utility of CT scans of the cervical spine in intoxicated patients with blunt trauma. We performed a prospective observational study of 1668 patients with blunt trauma aged 18 years and older who underwent cervical spine CT scans from March 2014 to March 2015 at an American College of Surgeons-verified Level I trauma center. Intoxication was determined by serum alcohol levels and urine drug screens. Physical examination and CT scan findings were evaluated for cervical spine injuries (CSI) and the incidence of missed injuries. Clinically relevant CSIs requiring cervical stabilization. The hypotheses formed prior to data collection were that cervical CT scans are sensitive and specific enough to diagnose CSIs that require stabilization and that normal CT scans are sufficient to clear CSIs in intoxicated patients. Of 1668 patients, 1103 (66.1%) were male, with a mean (SD) age of 49 (20) years and a mean (SD) Injury Severity Score of 10 (9). Vehicular (734 [44.0%]) and falls (579 [34.7%]) were the most common mechanisms for hospitalization. Intoxication was identified in 632 of 1429 of patients tested (44.2%; 425 [29.7%] by serum alcohol levels and 350 [24.5%] by urine drug screens). Half (316 [50.0%]) were admitted with cervical spine immobilization, and 38 (12%) of these were solely owing to the presence of intoxication. There were 65 abnormal CT scans (10.3%) in the intoxicated group. Among 567 normal CT scans, 4 (0.7%) had central cord syndrome found on initial physical examination, and 1 (0.2%) had a symptomatic unstable ligament injury that was misread as normal on CT scan but was abnormal on magnetic resonance imaging. The 316 patients kept in a cervical collar for intoxication had no missed CSIs but were kept immobilized for a mean (SD) of 12 (19) hours. Computed tomographic scans had an overall negative predictive value of 99.2% for patients with CSIs and a negative predictive value of 99.8% for ruling out CSIs that required immobilization or stabilization. In this study, alcohol or drug intoxication was common and resulted in significant delays to cervical spine clearance. Computed tomographic scans were highly reliable for identifying all clinically significant CSIs. Spine clearance based on a normal CT scan among intoxicated patients with no gross motor deficits appears to be safe and avoids prolonged and unnecessary immobilization.
NASA Astrophysics Data System (ADS)
Pfister, T.; Büttner, L.; Czarske, J.; Krain, H.; Schodl, R.
2006-07-01
This paper presents a novel fibre optic laser Doppler position sensor for single blade tip clearance and vibration measurements at turbo machines, which offers high temporal resolution and high position resolution simultaneously. The sensor principle is based on the generation of a measurement volume consisting of two superposed fan-like interference fringe systems with contrary fringe spacing gradients using wavelength division multiplexing. A flexible and robust measurement system with an all-passive fibre coupled measurement head has been realized employing diffractive and refractive optics. Measurements of tip clearance and rotor vibrations at a transonic centrifugal compressor performed during operation at up to 50 000 rpm (833 Hz) corresponding to 21.7 kHz blade frequency and 586 m s-1 blade tip velocity are presented. The results are in excellent agreement with those of capacitive probes. The mean uncertainty of the position measurement was around 20 µm and, thus, considerably better than for conventional tip clearance probes. Consequently, this sensor is capable of fulfilling the requirements for future active clearance control systems and has great potential for in situ and online tip clearance and vibration measurements at metallic and non-metallic turbine blades with high precision.
Impact of impaired renal function on the pharmacokinetics of the antiepileptic drug lacosamide.
Cawello, Willi; Fuhr, Uwe; Hering, Ursula; Maatouk, Haidar; Halabi, Atef
2013-10-01
The antiepileptic drug lacosamide is eliminated predominantly via the kidneys. Therefore, an evaluation of the impact of renal impairment on its pharmacokinetic profile is an important component of its safety assessment. The objective of this study was to evaluate the pharmacokinetic profile of lacosamide among individuals with renal impairment (mild, moderate, or severe) and among patients with end-stage renal disease (ESRD), including those on hemodialysis. This was an open-label, Phase I trial. The pharmacokinetics of a single oral 100-mg lacosamide dose were evaluated in five groups of participants: healthy controls, patients with mild, moderate, or severe renal impairment, and patients with ESRD (with and without hemodialysis). Forty participants completed the trial, eight in each group. In healthy volunteers, renal clearance accounted for approximately 30 % of total body clearance [geometric mean 0.5897 l/h (coefficient of variation 37.9 %) vs 2.13 l/h (20.8 %)]. With severe renal impairment, renal clearance was approximately 11 % of total body clearance [0.1428 l/h (31.8 %) vs 1.34 l/h (26.9 %)]. Terminal half-life and systemic exposure were increased with renal impairment, while total body clearance, renal clearance, and urinary excretion were decreased. Strong positive correlations between creatinine clearance, renal clearance, and urinary excretion were observed. Among patients with ESRD, approximately 50 % of lacosamide was cleared from systemic circulation by 4-h hemodialysis. In patients with essentially no renal clearance, nonrenal clearance was still present (1.1 l/h). Lacosamide was well tolerated by healthy volunteers and patients. In patients with mild-to-moderate renal impairment, lacosamide dose adjustment is not necessary, because total body clearance decreased by only approximately 20 %. Dose adjustment, however, is required for patients with severe renal impairment. Hemodialysis removes approximately 50 % of lacosamide from plasma; therefore, dose supplementation following hemodialysis should be considered.
Aban, Inmaculada B.; Wolfe, Gil I.; Cutter, Gary R.; Kaminski, Henry J.; Jaretzki, Alfred; Minisman, Greg; Conwit, Robin; Newsom-Davis, John
2008-01-01
We present our experience planning and launching a multinational, NIH/NINDS funded study of thymectomy in myasthenia gravis. We highlight the additional steps required for international sites and analyze and contrast the time investment required to bring U.S. and non-U.S. sites into full regulatory compliance. Results show the mean time for non- U.S. centers to achieve regulatory approval was significantly longer (mean 13.4 ± 0.96 months) than for U.S. sites (9.67 ± 0.74 months; p = 0.003, t-test). The delay for non- U.S. sites was mainly attributable to Federalwide Assurance certification and State Department clearance. PMID:18675464
Profile negotiation: An air/ground automation integration concept for managing arrival traffic
NASA Technical Reports Server (NTRS)
Williams, David H.; Arbuckle, P. Douglas; Green, Steven M.; Denbraven, Wim
1993-01-01
NASA Ames Research Center and NASA Langley Research Center conducted a joint simulation study to evaluate a profile negotiation process (PNP) between a time-based air traffic control ATC system and an airplane equipped with a four dimensional flight management system (4D FMS). Prototype procedures were developed to support the functional implementation of this process. The PNP was designed to provide an arrival trajectory solution that satisfies the separation requirements of ATC while remaining as close as possible to the airplane's preferred trajectory. The Transport Systems Research Vehicle cockpit simulator was linked in real-time to the Center/TRACON Automation System (CTAS) for the experiment. Approximately 30 hours of simulation testing were conducted over a three week period. Active airline pilot crews and active Center controller teams participated as test subjects. Results from the experiment indicate the potential for successful incorporation of airplane preferred arrival trajectories in the CTAS automation environment. Controllers were able to consistently and effectively negotiate nominally conflict-free trajectories with pilots flying a 4D-FMS-equipped airplane. The negotiated trajectories were substantially closer to the airplane's preference than would have otherwise been possible without the PNP. Airplane fuel savings relative to baseline CTAS were achieved in the test scenarios. The datalink procedures and clearances developed for this experiment, while providing the necessary functionality, were found to be operationally unacceptable to the pilots. Additional pilot control and understanding of the proposed airplane-preferred trajectory and a simplified clearance procedure were cited as necessary for operational implementation of the concept. From the controllers' perspective, the main concerns were the ability of the 4D airplane to accurately track the negotiated trajectory and the workload required to support the PNP as implemented in this study.
19 CFR 122.79 - Shipments to U.S. possessions.
Code of Federal Regulations, 2010 CFR
2010-04-01
... THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic Manifest Requirements for Passengers, Crew Members, and Non-Crew Members Onboard Commercial...
19 CFR 122.74 - Incomplete (pro forma) manifest.
Code of Federal Regulations, 2010 CFR
2010-04-01
... OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic Manifest Requirements for Passengers, Crew Members, and Non-Crew Members Onboard Commercial...
NASA Astrophysics Data System (ADS)
Hao, X. H.; Ju, Y. L.; Lu, Y. J.
2011-05-01
The labyrinth sealing displacer has been optimal designed to improve the operating stability and life-time of 10 K G-M refrigerator. The displacer was made of stainless steel 304 or inconel 718, coated with PTFE on its outer surface. Compared to the traditional piston-ring sealing displacer, the sealing clearance between the ridge of the labyrinth sealing displacer and cylinder is critical to the cooling performance of the G-M refrigerator. The displacers with different sealing clearances were experimentally studied, and the optimal clearance was given. The effects of the materials of the displacers and the system charge pressures on the performance of the labyrinth sealing were also tested and analyzed.
Berkiten, Güler; Kumral, Tolgar Lütfi; Saltürk, Ziya; Atar, Yavuz; Yildirim, Güven; Uyar, Yavuz; Aydoğdu, Imran; Arslanoğlu, Ahmet
2016-07-01
The aim of this study was to analyze the influence of deviated nasal septum (DNS) type on nasal mucociliary clearance, quality of life (QoL), olfactory function, and efficiency of nasal surgery (septoplasty with or without inferior turbinate reduction and partial middle turbinectomy). Fifty patients (20 females and 30 males) with septal deviation were included in the study and were divided into 6 groups according to deviation type after examination by nasal endoscopy and paranasal computed tomography. The saccharin clearance test to evaluate the nasal mucociliary clearance time, Connecticut Chemosensory Clinical Research Center smell test for olfactory function, and sinonasal outcome test-22 (SNOT-22) for patient satisfaction were applied preoperatively and postoperatively at the sixth week after surgery. Nasal mucociliary clearance, smell, and SNOT-22 scores were measured before surgery and at the sixth week following surgery. No significant difference was found in olfactory and SNOT-22 scores for any of the DNS types (both convex and concave sides) (P > 0.05). In addition, there was no difference in the saccharin clearance time (SCT) of the concave and convex sides (P > 0.05). According to the DNS type, the mean SCT of the convex sides showed no difference, but that of the concave sides showed a difference in types 3, 4, 5, and 6. These types had a prolonged SCT (P < 0.05). Olfactory scores revealed no difference postoperatively in types 5 and 6 but were decreased significantly in types 1 to 4 (P < 0.05). There was no significant difference in the healing of both the mucociliary clearance (MCC) and olfactory functions. SNOT-22 results showed a significant decrease in type 3. All DNS types disturb the QoL regarding nasal MCC and olfaction functions. MCC values, olfactory function, and QoL scores are similar among the DNS types. Both sides of the DNS types affect the MCC scores symmetrically. Septal surgery improves olfaction function and QoL at the sixth week following surgery but disturbs nasal MCC; thus, the sixth week is too early to assess nasal MCC.
Aerodynamic analysis of Audi A4 Sedan using CFD
NASA Astrophysics Data System (ADS)
Birwa, S. K.; Rathi, N.; Gupta, R.
2013-04-01
This paper presents the aerodynamic influence of velocity and ground clearance for Audi A4 Sedan. The topology of the test vehicle was modeled using CATIA P3 V5 R17. ANSYS FLUENT 12 was the CFD solver employed in this study. The distribution of pressure and velocity was obtained. The velocities were 30, 40, 50 and 60 m/s and ground clearances were 76.2 mm,101.6 mm,127 mm and 152.4 mm. The simulation results were compared with the available resources. It was found that the drag coefficient decreases with the velocity increasing from 30 to 60 m/s and increases with the ground clearance from 101.6 mm to 152.4 mm. Further decrease in ground clearance showed no effect on the value of coefficient of drag. The lift coefficient was found to decrease firstly with ground clearance from 152.4 mm to 101.6 mm, and then increase from 101.6 mm to 76.2 mm. Both the lift coefficient and drag coefficient was found to be minimum for the ground clearance of 101.6 mm as designed by the company.
NASA Technical Reports Server (NTRS)
Hahn, Edward C.; Hansman, R. J., Jr.
1992-01-01
An experiment to study how automation, when used in conjunction with datalink for the delivery of ATC clearance amendments, affects the situational awareness of aircrews was conducted. The study was focused on the relationship of situational awareness to automated Flight Management System (FMS) programming of datalinked clearances and the readback of ATC clearances. Situational awareness was tested by issuing nominally unacceptable ATC clearances and measuring whether the error was detected by the subject pilots. The experiment also varied the mode of clearance delivery: Verbal, Textual, and Graphical. The error detection performance and pilot preference results indicate that the automated programming of the FMS may be superior to manual programming. It is believed that automated FMS programming may relieve some of the cognitive load, allowing pilots to concentrate on the strategic implications of a clearance amendment. Also, readback appears to have value, but the small sample size precludes a definite conclusion. Furthermore, because textual and graphical modes of delivery offer different but complementary advantages for cognitive processing, a combination of these modes of delivery may be advantageous in a datalink presentation.
Lung clearance of /sup 99m/Tc-DTPA in patients with acute lung injury and pulmonary edema
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coates, G.; O'Brodovich, H.; Dolovich, M.
1988-07-01
Several acute and chronic conditions that alter the integrity of the pulmonary epithelium increased the rate of absorption or clearance into the circulation of small solutes deposited in the alveoli. Technetium 99m diethylenetriamine pentaacetic acid can be deposited in the lungs as a submicronic aerosol and its rate of clearance measured with a gamma camera or simple probe. This clearance technique is currently being used to evaluate patients who have developed pulmonary edema and also to detect those patients from a high risk group who are likely to develop adult respiratory distress syndrome (ARDS). Its role in the evaluation ofmore » patients with pulmonary edema is still under active investigation. It is clear that a single measurement in patients who smoke is not useful, but repeated measurements may provide important information. The lung clearance measurement is very sensitive to changes in epithelial integrity but is not specific for ARDS. It may be most useful in combination with other predictive tests or when the clearance rate is normal. 54 references.« less
Deng, Meihong; Loughran, Patricia; Gibson, Gregory; Sodhi, Chhinder; Watkins, Simon; Hackam, David
2013-01-01
The morbidity associated with bacterial sepsis is the result of host immune responses to pathogens, which are dependent on pathogen recognition by pattern recognition receptors, such as TLR4. TLR4 is expressed on a range of cell types, yet the mechanisms by which cell-specific functions of TLR4 lead to an integrated sepsis response are poorly understood. To address this, we generated mice in which TLR4 was specifically deleted from myeloid cells (LysMTLR4KO) or hepatocytes (HCTLR4KO) and then determined survival, bacterial counts, host inflammatory responses, and organ injury in a model of cecal ligation and puncture (CLP), with or without antibiotics. LysM-TLR4 was required for phagocytosis and efficient bacterial clearance in the absence of antibiotics. Survival, the magnitude of the systemic and local inflammatory responses, and liver damage were associated with bacterial levels. HCTLR4 was required for efficient LPS clearance from the circulation, and deletion of HCTLR4 was associated with enhanced macrophage phagocytosis, lower bacterial levels, and improved survival in CLP without antibiotics. Antibiotic administration during CLP revealed an important role for hepatocyte LPS clearance in limiting sepsis-induced inflammation and organ injury. Our work defines cell type–selective roles for TLR4 in coordinating complex immune responses to bacterial sepsis and suggests that future strategies for modulating microbial molecule recognition should account for varying roles of pattern recognition receptors in multiple cell populations. PMID:23562812
43 CFR 2920.2-1 - Discussion of proposals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... in conformance with Bureau of Land Management policies and programs for the lands, local zoning... requirements; associated clearances, other permits or licenses which may be required; environmental and...
Vázquez Rodríguez, Juan Gustavo; Cruz Cruz, Polita del Rocío; Márquez Hubert, Elizabeth
2009-07-01
Tubular lesion may cause acute renal insufficiency in pregnant patients with severe preeclampsia. To describe the correlation between the amylase/creatinine clearance ratio and endogenous creatinine depuration in pregnant patients with severe preeclampsia. Transversal study (pilot study) twenty eight women with pregnancies of 20 to 40 weeks complicated by severe preeclampsia were studied. Subjects had serum and urine creatinine and amylase determinations to calculate the amylase/creatinine clearance ratio (%). According to the results, two groups were formed: group A (> 3%) and group B (< or = 3%). The correlation between amylase/creatinine clearance ratio and endogenous creatinine depuration was evaluated. measures of central tendency and dispersion, Student's t-test, Pearson correlation coefficient (r) and linear regression were used. Group A included 23 cases (82%) and group B included 5 cases (18%). Amylase/creatinine clearance ratio (%) for group A was 5.22 +/- 1.6 and for group B was 2.41 +/- 0.41 (p = 0.001). The endogenous creatinine depuration (mL /min. /1.73 m2 SC) for group A was 105.6 +/- 9.71 and for group B was 132.10 +/- 7.95 (p = 0.54). The r between amylase/creatinine clearance ratio and endogenous creatinine depuration for group A was -0.43 and for group B was -0.25. A moderately significant negative correlation exists between amylase/creatinine clearance ratio and endogenous creatinine depuration.
Hans, Rinki; Thomas, Susan; Garla, Bharat; Dagli, Rushabh J; Hans, Manoj Kumar
2016-01-01
Introduction. Diet is a major aetiological factor for dental caries and enamel erosion. This study was undertaken with the aim of assessing the effect of selected locally available beverages on salivary pH, flow rate, and oral clearance rate amongst adults. Materials and Method. This clinical trial comprised 120 subjects. Test beverages undertaken were pepsi, fruit drink, coffee, and sweetened milk. Statistical analysis was carried out using SPSS version 17. Descriptive statistics, one-way ANOVA, and post hoc Tukey's test were applied in the statistical tests. Results. It was found that salivary pH decreased for all the beverages immediately after consumption and the salivary flow rate increased after their consumption. The oral clearance rate of sweetened milk was found to be the least at 6.5 minutes and that of pepsi was found to be 13 minutes. However, the oral clearance rates of fruit drink and coffee were found to be equal at 15 minutes. Conclusion. Although it was found out that liquids cleared rapidly from the oral cavity, they had a significant cariogenic and erosive potential. Hence, it is always advised to minimise the consumption of beverages, especially amongst children and young adults to maintain a good oral health.
Effect of Various Sugary Beverages on Salivary pH, Flow Rate, and Oral Clearance Rate amongst Adults
Hans, Rinki; Thomas, Susan; Garla, Bharat; Dagli, Rushabh J.
2016-01-01
Introduction. Diet is a major aetiological factor for dental caries and enamel erosion. This study was undertaken with the aim of assessing the effect of selected locally available beverages on salivary pH, flow rate, and oral clearance rate amongst adults. Materials and Method. This clinical trial comprised 120 subjects. Test beverages undertaken were pepsi, fruit drink, coffee, and sweetened milk. Statistical analysis was carried out using SPSS version 17. Descriptive statistics, one-way ANOVA, and post hoc Tukey's test were applied in the statistical tests. Results. It was found that salivary pH decreased for all the beverages immediately after consumption and the salivary flow rate increased after their consumption. The oral clearance rate of sweetened milk was found to be the least at 6.5 minutes and that of pepsi was found to be 13 minutes. However, the oral clearance rates of fruit drink and coffee were found to be equal at 15 minutes. Conclusion. Although it was found out that liquids cleared rapidly from the oral cavity, they had a significant cariogenic and erosive potential. Hence, it is always advised to minimise the consumption of beverages, especially amongst children and young adults to maintain a good oral health. PMID:27051556
Factors effective on peritoneal phosphorus transport and clearance in peritoneal dialysis patients .
Cebeci, Egemen; Gursu, Meltem; Uzun, Sami; Karadag, Serhat; Kazancioglu, Rumeyza; Ozturk, Savas
2017-02-01
Transport characteristics of phosphorus are different from other small solutes that are evaluated in routine peritoneal equilibration test (PET) in peritoneal dialysis (PD) patients. We aimed to evaluate peritoneal phosphorus clearance and permeability, and their relationship with peritoneal membrane transport type and creatinine clearance as well as factors affecting peritoneal phosphorus clearance. 70 adult patients on a PD program were included in our study. Phosphorus transport status was classified according to dialysate/plasma (D/P) phosphorus at the 4th hour of PET as slow transporter (< 0.47), slow-average transporter (0.47 - 0.56), fast-average transporter (0.57 - 0.67), and fast transporter (> 0.67). We evaluated the relationship of peritoneal phosphorus clearance and transport type with PD regime, phosphorus level, and presence of residual renal function in addition to investigating factors that are effective on peritoneal phosphorus clearance. D/P phosphorus and peritoneal phosphorus clearance were positively correlated with D/P creatinine and peritoneal creatinine clearance, respectively. Automated PD and continuous ambulatory PD patients were similar regarding phosphorus and creatinine clearances and transport status based on D/P phosphorus. The major determinant of peritoneal phosphorus clearance was anuria status. Anuric patients had higher dialysate volume (11.6 ± 3.0 L vs. 8.4 ± 2.1 L, p < 0.001) and therefore higher peritoneal phosphorus clearance (61.7 ± 15.1 L/week/1.73 m2 vs. 48.4 ± 14.0 L/week/1.73 m2, p = 0.001). Hyperphosphatemia was present in 40% and 11% of anuric patients and those with residual renal function, respectively (p = 0.005). Peritoneal phosphorus transport characteristics are similar to that of creatinine. Although increased dialysis dose may increase peritoneal phosphorus clearance, it may be insufficient to prevent hyperphosphatemia in anuric patients. .
Moqueet, Nasheed; Infante-Rivard, Claire; Platt, Robert W; Young, Jim; Cooper, Curtis; Hull, Mark; Walmsley, Sharon; Klein, Marina B
2015-03-20
Canadian Aboriginals are reported to clear Hepatitis C (HCV) more frequently. We tested the association of spontaneous clearance and three single nucleotide polymorphisms (SNPs) near the Interferon-lambda 3 (IFNL3) gene (rs12979860, rs8099917, functional variant rs8103142) and compared the SNP frequencies between HIV-HCV co-infected whites and Aboriginals from the Canadian Co-infection Cohort. HCV treatment-naïve individuals with at least two HCV RNA tests were included (n = 538). A spontaneous clearance case was defined as someone with two consecutive HCV RNA-negative tests, at least six months apart. Data were analyzed using Cox proportional hazards adjusted for sex and ethnicity. Advantageous variants and haplotypes were more common in Aboriginals than Caucasians: 57% vs. 46% had the rs12979860 CC genotype, respectively; 58% vs. 48%, rs8103142 TT; 74% vs. 67%, the rs12979860 C allele; and 67% vs. 64% the TCT haplotype with three favourable alleles. The adjusted Hazard Ratios (95% CI) for spontaneous clearance were: rs12979860: 3.80 (2.20, 6.54); rs8099917: 5.14 (2.46, 10.72); and rs8103142: 4.36 (2.49, 7.62). Even after adjusting for rs12979860, Aboriginals and females cleared HCV more often, HR (95% CI) = 1.53 (0.89, 2.61) and 1.42 (0.79, 2.53), respectively. Our results suggest that favourable IFNL3 genotypes are more common among Aboriginals than Caucasians, and may partly explain the higher HCV clearance rates seen among Aboriginals.
NASA Astrophysics Data System (ADS)
Tomassini, R.; Rossi, G.; Brouckaert, J.-F.
2014-05-01
The accurate control of the gap between static and rotating components is vital to preserve the mechanical integrity and ensure a correct functioning of any rotating machinery. Moreover, tip leakage above the airfoil tip results in relevant aerodynamic losses. One way to measure and to monitor blade tip gaps is by the so-called Blade Tip Clearance (BTC) technique. Another fundamental phenomenon to control in the turbomachines is the vibration of the blades. For more than half a century, this has been performed by installing strain gauges on the blades and using telemetry to transmit the signals. The Blade Tip Timing (BTT) technique, (i.e. measuring the blade time of arrival from the casing at different angular locations with proximity sensors) is currently being adopted by all manufacturers as a replacement for the classical strain gauge technique because of its non-intrusive character. This paper presents a novel magnetoresistive sensor for blade tip timing and blade tip clearance systems, which offers high temporal and high spatial resolution simultaneously. The sensing element adopted is a Wheatstone bridge of Permalloy elements. The principle of the sensor is based on the variation of magnetic field at the passage of ferromagnetic objects. Two different configurations have been realized, a digital and an analogue sensor. Measurements of tip clearance have been performed in an high speed compressor and the calibration curve is reported. Measurements of blade vibration have been carried out in a dedicated calibration bench; results are presented and discussed. The magnetoresistive sensor is characterized by high repeatability, low manufacturing costs and measurement accuracy in line with the main probes used in turbomachinery testing. The novel sensor has great potential and is capable of fulfilling the requirements for a simultaneous BTC and BTT measurement system.
Evaluation of a Microwave Blade Tip Clearance Sensor for Propulsion Health Monitoring
NASA Technical Reports Server (NTRS)
Woike, Mark R.
2013-01-01
The NASA Glenn Research Center has investigated a microwave blade tip clearance system for the structural health monitoring of gas turbine engines. This presentation describes the sensors and the experiments that have been conducted to evaluate their performance along with future plans for their use on an engine ground test.
Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane
NASA Technical Reports Server (NTRS)
Gera, Joseph; Bosworth, John T.
1987-01-01
This paper describes some novel flight tests and analysis techniques in the flight dynamics and handling qualities area. These techniques were utilized during the initial flight envelope clearance of the X-29A aircraft and were largely responsible for the completion of the flight controls clearance program without any incidents or significant delays. The resulting open-loop and closed-loop frequency responses and the time history comparison using flight and linear simulation data are discussed.
Impeller leakage flow modeling for mechanical vibration control
NASA Technical Reports Server (NTRS)
Palazzolo, Alan B.
1996-01-01
HPOTP and HPFTP vibration test results have exhibited transient and steady characteristics which may be due to impeller leakage path (ILP) related forces. For example, an axial shift in the rotor could suddenly change the ILP clearances and lengths yielding dynamic coefficient and subsequent vibration changes. ILP models are more complicated than conventional-single component-annular seal models due to their radial flow component (coriolis and centrifugal acceleration), complex geometry (axial/radial clearance coupling), internal boundary (transition) flow conditions between mechanical components along the ILP and longer length, requiring moment as well as force coefficients. Flow coupling between mechanical components results from mass and energy conservation applied at their interfaces. Typical components along the ILP include an inlet seal, curved shroud, and an exit seal, which may be a stepped labyrinth type. Von Pragenau (MSFC) has modeled labyrinth seals as a series of plain annular seals for leakage and dynamic coefficient prediction. These multi-tooth components increase the total number of 'flow coupled' components in the ILP. Childs developed an analysis for an ILP consisting of a single, constant clearance shroud with an exit seal represented by a lumped flow-loss coefficient. This same geometry was later extended to include compressible flow. The objective of the current work is to: supply ILP leakage-force impedance-dynamic coefficient modeling software to MSFC engineers, base on incompressible/compressible bulk flow theory; design the software to model a generic geometry ILP described by a series of components lying along an arbitrarily directed path; validate the software by comparison to available test data, CFD and bulk models; and develop a hybrid CFD-bulk flow model of an ILP to improve modeling accuracy within practical run time constraints.
3D gait assessment in young and elderly subjects using foot-worn inertial sensors.
Mariani, Benoit; Hoskovec, Constanze; Rochat, Stephane; Büla, Christophe; Penders, Julien; Aminian, Kamiar
2010-11-16
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment. Copyright © 2010 Elsevier Ltd. All rights reserved.
19 CFR 122.76 - Shipper's Export Declarations and inspection certificates.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic Manifest Requirements for Passengers, Crew Members, and Non-Crew Members...
19 CFR 122.72 - Aircraft departing with commercial export cargo.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic Manifest Requirements for Passengers, Crew Members, and Non-Crew Members...
Inanli, Selçuk; Oztürk, Ozmen; Korkmaz, Mukadder; Tutkun, Alper; Batman, Cağlar
2002-02-01
The aims of the study were to determine: 1) how mucociliary activity in acute bacterial rhinosinusitis is affected; 2) how this activity is changed by therapy; 3) the effects of topical agents on mucociliary clearance, and 4) the most appropriate topical agent(s) to be used in the therapy of sinusitis. Five groups of patients with acute bacterial rhinosinusitis were studied prospectively. All patients had 500 mg oral amoxicillin and 125 mg oral clavulanic acid preparations given three times daily for 3 weeks. According to the topical agent applications, these groups included: group I (n = 12), no topical treatment was given; group II (n = 14), two puffs for each nostril once daily of 50 microg/100 mL fluticasone propionate was given; group III (n = 9), one puff for each nostril three times daily of 0.05% oxymetazoline was given; group IV (n =12), 3% sodium chloride (NaCl) (buffered to pH 6.5-7 at room temperature) was given; and group V (n =13), 10-mL solutions of 0.9% NaCl (buffered to pH 6.5--7 at room temperature) were given for nasal irrigations three times daily. All patients had medication for 3 weeks and were controlled each week. The saccharin method was used to measure nasal mucociliary clearance. To investigate the early effects of the topical agents for groups II to V, an additional test was repeated 20 minutes after the basal mucociliary clearance recordings. The test was repeated in the first, second, and third weeks of the treatment. The mucociliary clearance was significantly slower in the acute bacterial rhinosinusitis group than in the control group. There was no significant difference between the basal mucociliary clearance and the 20th minute mucociliary clearance of the fluticasone propionate and 0.9% NaCl solution groups. The mean values of the basal and the 20 minute's mucociliary clearance of the oxymetazoline group were 24.72 +/- 6.16 and 15.5 +/- 7.45 minutes, respectively, which were statistically significant. The mean values of the basal and the 20th minute mucociliary clearance of the 3% NaCl solution groups were 19.45 +/- 9.35 and 15.45 +/- 8.20 minutes, respectively, which were also statistically significant. In the first group (without topical treatment), the basal mucociliary clearance became significantly shorter after the second week of treatment. In the first and second weeks of the treatment of the oxymetazoline group, the mucociliary clearance did not change significantly, but after the third week the mucociliary clearance was significantly shorter. In the 3% NaCl solution group, significant improvement began from the first week and continued through the third week. Comparing the basal and the third weeks' mucociliary clearance values among the groups, the oxymetazoline and 3% NaCl solution groups revealed more significant improvement than the other groups, but this improvement was not different from the improvement of group I. There was still a statistically significant difference in the mucociliary clearance of the post-treatment sinusitis groups from the control group. The oxymetazoline and 3% NaCl solution groups seemed to be more effective in mucociliary clearance, but there was no significant difference in improvement among the groups. The improvement of acute bacterial rhinosinusitis takes more than 3 weeks, according to the mucociliary clearance values of the groups.
78 FR 11263 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-15
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of reporting requirements submitted for OMB review... notice to: Agency Clearance Officer, Curtis Rich, [email protected] Small Business Administration, 409...
Selectively increasing the clearance of protein-bound uremic solutes
Luo, Frank J.-G.; Plummer, Natalie S.; Hostetter, Thomas H.; Meyer, Timothy W.
2012-01-01
Background. The toxicity of bound solutes could be better evaluated if we could adjust the clearance of such solutes independent of unbound solutes. This study assessed whether bound solute clearances can be increased while maintaining urea clearance constant during the extended hours of nocturnal dialysis. Methods. Nine patients on thrice-weekly nocturnal dialysis underwent two experimental dialysis treatments 1 week apart. The experimental treatments were designed to provide the same urea clearance while providing widely different bound solute clearance. One treatment employed a large dialyzer and high dialyzate flow rate (Qd) of 800 mL/min while blood flow (Qb) was 270 mL/min. The other treatment employed a smaller dialyzer and Qd of 300 mL/min while Qb was 350 mL/min. Results. Treatment with the large dialyzer and higher Qd greatly increased the clearances of the bound solutes p-cresol sulfate (PCS: 27 ± 9 versus 14 ± 6 mL/min) and indoxyl sulfate (IS: 26 ± 8 versus 14 ± 5 mL/min) without altering the clearance of urea (204 ± 20 versus 193 ± 16 mL/min). Increasing PCS and IS clearances increased the removal of these solutes (PCS: 375 ± 200 versus 207 ± 86 mg/session; IS: 201 ± 137 versus 153 ± 74 mg/session), while urea removal was not different. Conclusions. The removal of bound solutes can thus be increased by raising the dialyzate flow and dialyzer size above the low levels sufficient to achieve target Kt/Vurea during extended treatment. Selectively increasing the clearance of bound solutes provides a potential means to test their toxicity. PMID:22231033
Gref, Margareta C; Karp, Kjell H
2009-03-01
The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.
Hierarchical Control Scheme for Improving Transient Voltage Recovery of a DFIG-Based WPP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jinho; Muljadi, Eduard; Kang, Yong Cheol
Modern grid codes require that wind power plants (WPPs) inject reactive power according to the voltage dip at a point of interconnection (POI). This requirement helps to support a POI voltage during a fault. However, if a fault is cleared, the POI and wind turbine generator (WTG) voltages are likely to exceed acceptable levels unless the WPP reduces the injected reactive power quickly. This might deteriorate the stability of a grid by allowing the disconnection of WTGs to avoid any damage. This paper proposes a hierarchical control scheme of a doubly-fed induction generator (DFIG)-based WPP. The proposed scheme aims tomore » improve the reactive power injecting capability during the fault and suppress the overvoltage after the fault clearance. To achieve the former, an adaptive reactive power-to-voltage scheme is implemented in each DFIG controller so that a DFIG with a larger reactive power capability will inject more reactive power. To achieve the latter, a washout filter is used to capture a high frequency component contained in the WPP voltage, which is used to remove the accumulated values in the proportional-integral controllers. Test results indicate that the scheme successfully supports the grid voltage during the fault, and recovers WPP voltages without exceeding the limit after the fault clearance.« less
Mishra, Shashikant; Sabnis, Ravindra B; Kurien, Abraham; Ganpule, Arvind; Muthu, Veeramani; Desai, Mahesh
2010-10-01
To establish the efficacy of early removal of a nephrostomy tube after percutaneous nephrolithotomy (PCNL), to challenge the wisdom of tubeless PCNL, as we hypothesized that it would result in a shorter hospital stay, comparable benefit and safety, while maintaining the option of check nephroscopy ensuring far superior stone clearance. In all, 22 patients were prospectively randomized equally into two groups, group 1 (early nephrostomy removal) or group 2 (tubeless) during a 1-month study period. Inclusion criteria for the study were: a simple stone of <3 cm, no significant bleeding, no perforation, single-tract access and 'on-table' complete stone clearance. In group 1, a 20 F nephrostomy, 6 F retrograde ureteric catheter and a Foley catheter were used, while in group 2 only a 6 F retrograde ureteric catheter and Foley catheter were placed at the end of the procedure. Computed tomography (CT) with no contrast medium was done on the first morning after surgery before removing all catheters/tubes, and patients discharged subsequently. The variables assessed were stone clearance, hospital stay, analgesic requirement, postoperative complications and auxiliary procedures. The mean (SD) stone bulk was similar between the groups, at 2737 (946.9) and 2934.2 (2090.7) µL, respectively. Despite an on-table complete clearance, clearance assessed by CT was nine of 11 vs eight of 11 in groups 1 and 2, respectively. CT showed a 6 mm stone in one patient in group 1, while the remaining patients had stones of <4 mm. The mean (SD) analgesic requirement, haemoglobin decrease, urine leak and hospital stay in the two groups were 72.7 (51.8) vs 68.2 (46.2) mg of tramadol (P= 0.25), 1.6 (0.7) vs 1.6 (0.9) g/dL (P= 0.39), 13.9 (6.3) vs 7.1 (14.2) h (P= 0.018) and 72.8 (2.1) vs 70.2 (18.5) h (P= 0.09), respectively. Complications noted were early haematuria in none vs three (P= 0.21), urinoma none vs one, and fever in two vs one, respectively; one patient in group 1 required a check nephroscopy for a residual fragment. Overall clearance including re-treatment was 10/11 vs eight of 11 (P= 0.009), respectively. Early tube removal after PCNL results in an equivalent analgesic requirement, decrease in haemoglobin and hospital stay as tubeless PCNL. It has a significantly lower incidence of early haematuria, better clearance rates and preserves the option of check nephroscopy. It can be considered as an accepted standard of care, with the preserved advantages of tubeless PCNL. © 2010 THE AUTHORS. JOURNAL COMPILATION © 2010 BJU INTERNATIONAL.
19 CFR 122.71 - Aircraft departing with no commercial export cargo.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic Manifest Requirements for Passengers, Crew Members, and Non-Crew Members...
19 CFR 122.73 - General declaration and air cargo manifest.
Code of Federal Regulations, 2010 CFR
2010-04-01
...; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic Manifest Requirements for Passengers, Crew Members, and Non-Crew Members Onboard Commercial...
NASA Technical Reports Server (NTRS)
Elrod, D. A.; Childs, D. W.
1986-01-01
A brief review of current annular seal theory and a discussion of the predicted effect on stiffness of tapering the seal stator are presented. An outline of Nelson's analytical-computational method for determining rotordynamic coefficients for annular compressible-flow seals is included. Modifications to increase the maximum rotor speed of an existing air-seal test apparatus at Texas A&M University are described. Experimental results, including leakage, entrance-loss coefficients, pressure distributions, and normalized rotordynamic coefficients, are presented for four convergent-tapered, smooth-rotor, smooth-stator seals. A comparison of the test results shows that an inlet-to-exit clearance ratio of 1.5 to 2.0 provides the maximum direct stiffness, a clearance ratio of 2.5 provides the greatest stability, and a clearance ratio of 1.0 provides the least stability. The experimental results are compared to theoretical results from Nelson's analysis with good agreement. Test results for cross-coupled stiffness show less sensitivity of fluid prerotation than predicted.
Aoyama, T; Hirata, K; Yamamoto, Y; Yokota, H; Hayashi, H; Aoyama, Y; Matsumoto, Y
2016-08-01
Midazolam (MDZ) is commonly used for sedating critically ill patients. The daily dose required for adequate sedation increases in increments over 100 h after administration. The objectives of this study were to characterize the MDZ pharmacokinetics in critically ill patients and to describe the phenomenon of increasing daily dose by means of population pharmacokinetic analysis. Data were obtained from 30 patients treated in an intensive care unit. The patients received MDZ intravenously as a combination of bolus and continuous infusion. Serum MDZ concentration was assayed by high-performance liquid chromatography. Population pharmacokinetic analysis was performed using the NONMEM software package. The alteration of clearance unexplained by demographic factors and clinical laboratory data was described as an autoinduction of MDZ clearance using a semi-mechanistic pharmacokinetic-enzyme turnover model. The final population pharmacokinetic model was a one-compartment model estimated by incorporating a semi-mechanistic pharmacokinetic-enzyme turnover model for clearance, taking autoinduction into account. A significant covariate for MDZ clearance was total bilirubin. An increase in total bilirubin indicated a reduction in MDZ clearance. From simulation using the population pharmacokinetic parameters obtained in this study, MDZ clearance increased 2·3 times compared with pre-induced clearance 100 h after the start of 12·5 mg/h continuous infusion. Autoinduction and total bilirubin were significant predictors of the clearance of MDZ in this population. Step-by-step dosage adjustment using this population pharmacokinetic model may be useful for establishing a MDZ dosage regimen in critically ill patients. © 2016 John Wiley & Sons Ltd.
Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals
NASA Technical Reports Server (NTRS)
Delgado, Irebert R.; Proctor, Margaret P.
2007-01-01
Seal leakage decreases with increasing surface speed due to reduced clearances from disk centrifugal growth. Annular and labyrinth seal leakage are 2-3 times greater than brush and finger seal leakage. Seal leakage rates increase with increasing temperature because of seal clearance growth due to different coefficients of thermal expansion between the seal and test disk. Seal power loss is not strongly affected by inlet temperature. Seal power loss increases with increasing surface speed, seal pressure differential, mass flow rate or flow factor, and radial clearance. The brush and finger seals had nearly the same power loss. Annular and labyrinth seal power loss were higher than finger or brush seal power loss. The brush seal power loss was the lowest and 15-30% lower than annular and labyrinth seal power loss.
Effects of airborne pollutants on mucociliary clearance.
Wolff, R K
1986-04-01
The mucociliary clearance system is a first line of defense against inhaled agents, and so its compromise can adversely affect health. The purpose of this paper is to provide a review of data on the effect of in vivo air pollutant exposures on the clearance of test particles from airways. Data from both animals and humans are compared whenever possible, so that estimates of human health effects may be made. Mechanisms of action are also discussed, presenting the view that for low level exposures, changes in secretions are probably responsible for most observed changes in clearance. The pollutants pertinent to this review are those that are common in the environment and most likely to have impacts on large numbers of people: sulfur oxides, sulfuric acid mist, O3, NO2, particulates, diesel exhaust, and cigarette smoke.
Banister, Carolyn E.; Messersmith, Amy R.; Cai, Bo; Spiryda, Lisa B.; Glover, Saundra H.; Pirisi, Lucia; Creek, Kim E.
2015-01-01
Background. Cervical cancer incidence and mortality rates are higher in African Americans than in European Americans (white, non-Hispanic of European ancestry). The reasons for this disparity are not known. Methods. We recruited a population-based longitudinal cohort of 326 European American and 113 African American female college freshmen in Columbia, South Carolina, to compare clearance of high-risk human papillomavirus (HR-HPV) infection between ethnicities. HPV testing and typing from samples obtained for Papanicolaou testing occurred every 6 months. Results. African American participants had an increased risk of testing positive for HR-HPV, compared with European American participants, but the frequency of incident HPV infection was the same in African American and European American women. Thus, exposure to HPV could not explain the higher rate of HPV positivity among African American women. The time required for 50% of participants to clear HR-HPV infection was 601 days for African American women (n = 63) and 316 days for European American women (n = 178; odds ratio [OR], 1.61; 95% confidence interval [CI], 1.08–2.53). African American women were more likely than European American women to have an abnormal result of a Papanicolaou test (OR, 1.58; 95% CI, 1.05–2.39). Conclusions. We propose that the longer time to clearance of HR-HPV among African American women leads to increased rates of abnormal results of Papanicolaou tests and contributes to the increased rates of cervical cancer observed in African American women. PMID:25028692
Impaired Urine Dilution Capability in HIV Stable Patients
Belloso, Waldo H.; de Paz Sierra, Mariana; Navarro, Matilde; Sanchez, Marisa L.; Perelsztein, Ariel G.; Musso, Carlos G.
2014-01-01
Renal disease is a well-recognized complication among patients with HIV infection. Viral infection itself and the use of some antiretroviral drugs contribute to this condition. The thick ascending limb of Henle's loop (TALH) is the tubule segment where free water clearance is generated, determining along with glomerular filtration rate the kidney's ability to dilute urine. Objective. We analyzed the function of the proximal tubule and TALH in patients with HIV infection receiving or not tenofovir-containing antiretroviral treatment in comparison with healthy seronegative controls, by applying a tubular physiological test, hyposaline infusion test (Chaimowitz' test). Material & Methods. Chaimowitz' test was performed on 20 HIV positive volunteers who had normal renal functional parameters. The control group included 10 healthy volunteers. Results. After the test, both HIV groups had a significant reduction of serum sodium and osmolarity compared with the control group. Free water clearance was lower and urine osmolarity was higher in both HIV+ groups. Proximal tubular function was normal in both studied groups. Conclusion. The present study documented that proximal tubule sodium reabsorption was preserved while free water clearance and maximal urine dilution capability were reduced in stable HIV patients treated or not with tenofovir. PMID:24800076
Differences in Mucociliary activity of volunteers undergoing Ramadan versus Nineveh fasting.
Develioglu, Omer Necati; Sirazi, Sait; Topak, Murat; Purisa, Sevim; Kulekci, Mehmet
2013-05-01
This study, aimed to evaluate the difference in mucociliary clearance among volunteers who underwent Ramadan versus Nineveh fasting regimens as well as the difference between the fasting period and 4 weeks following the fasting period in both groups. In this study, two different fasting groups were established: Ramadan (fasting for an average of 15 h for 29 consecutive days, n = 40) and Nineveh (60 h of nonstop fasting, n = 26). Subjects in each group underwent saccharin testing twice: at the end of the fasting period prior to resumption of eating and at 4 weeks after the end of Ramadan or Nineveh fasting. Statistical analysis was performed using the Mann-Whitney U-test, Wilcoxon, Chi-square, and paired t test. A p value less than 0.05 was considered statistically significant. Forty subjects who underwent Ramadan fasting and 26 subjects who underwent Nineveh fasting were included in this study. Of the 66 study participants, 34 (51.5 %) were men and 32 (48.5 %) were women. Their median age was 31 years (range 17-70 years) for Nineveh fasting subjects and 40 years (range 17-70 years) for Ramadan fasting subjects. Chi-square tests revealed no significant difference between the Ramadan and Nineveh fasting groups in gender (p = 0.418), and the Mann-Whitney U-test showed no difference in age. A statistically significant difference was found in the mucociliary clearance time between the Nineveh fasting and non-fasting periods (p = 0.013). Using Wilcoxon signed-rank tests, we found no significant difference in the mucociliary clearance time between the Ramadan fasting and control (4 weeks after the fasting period) periods (p = 0.121). The percentage difference between the fasting and control periods was similar between groups and was not statistically significant for the Ramadan and Nineveh fasting groups (p = 0.086). The results of the present study indicated that long-term fasting with hypohydration contributed to the deterioration of nasal mucociliary clearance. Our data indicate that optimal hydration, sleep patterns, and fasting times contribute to proper mucociliary clearance.
Chumworathayi, Bandit; Thinkhamrop, Jadsada; Blumenthal, Paul D; Thinkhamrop, Bandit; Pientong, Chamsai; Ekalaksananan, Tipaya
2010-02-01
To compare the clearance rate of HPV infection among women aged older than 30 years with biopsy-confirmed cervical low-grade squamous intraepithelial lesions (LSIL) 1 year after cryotherapy with the spontaneous clearance rate (observation). HPV DNA typing by polymerase chain reaction and reverse line blot hybridization were used to identify 14 high-risk types and 23 low-risk types. HPV DNA sequencing was also used for other types. Between December 2007 and March 2009, 100 women were recruited to the study and 60 cases had positive results on HPV testing. Twenty-nine patients were randomly allocated to the cryotherapy group and 31 to the observation group. At 1 year, 89.7% (26/29; 95% CI, 78.6-100%) of the cryotherapy group and 90.3% (28/31; 95% CI, 79.9-100%) of the observation group had negative results on HPV testing (0.6% difference; 95% CI, -15.8 to 14.6%, P=0.94). Cryotherapy failed to increase the clearance of prevalent HPV infections among women with LSIL, although in both arms the clearance rates were above 80%. However, in coupling with visual inspection with acetic acid as a single visit approach, its effect on prevention of HSIL and cervical cancer is still promising. Therefore, cryotherapy should not be withdrawn from such programs. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
75 FR 63215 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-14
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of Reporting Requirements Submitted for OMB Review... notice to: Agency Clearance Officer, Jacqueline White, Small Business Administration, 409 3rd Street, SW...
75 FR 23310 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-03
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of Reporting Requirements Submitted for OMB Review... notice to: Agency Clearance Officer, Jacqueline White, Small Business Administration, 409 3rd Street, SW...
76 FR 408 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-04
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of reporting requirements submitted for OMB review... notice to: Agency Clearance Officer, Jacqueline White, Small Business Administration, 409 3rd Street, SW...
76 FR 18821 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-05
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of reporting requirements submitted for OMB review... notice to: Agency Clearance Officer, Jacqueline White, Small Business Administration, 409 3rd Street, SW...
Rectenna System Design. [energy conversion solar power satellites
NASA Technical Reports Server (NTRS)
Woodcock, G. R.; Andryczyk, R. W.
1980-01-01
The fundamental processes involved in the operation of the rectenna system designed for the solar power satellite system are described. The basic design choices are presented based on the desired microwave rf field concentration prior to rectification and based on the ground clearance requirements for the rectenna structure. A nonconcentrating inclined planar panel with a 2 meter minimum clearance configuration is selected as a representative of the typical rectenna.
The effect of oral and intravenous dextrose on C-peptide secretion in ponies.
de Laat, M A; van Haeften, J J; Sillence, M N
2016-02-01
Managing equine hyperinsulinemia is crucial for preventing laminitis, but our understanding of the mechanisms involved in insulin dysregulation in this species is incomplete. C-peptide is co-secreted with insulin but is resistant to hepatic metabolism and can be used to study insulin dysregulation. This study examined C-peptide secretion in serial blood samples collected after oral and i.v. dextrose (0.75 g/kg) administration to 9 ponies (BCS, 7.1 ± 0.5). The ponies were designated as hyperinsulinemic (HI) or normoinsulinemic (NI) responders before the study, using oral glucose tests and fasted glucose-to-insulin ratios, and responses were compared between the 2 groups. C-peptide concentrations increased ( < 0.01) rapidly from fasted levels after both oral and i.v. dextrose, with similar area under the concentration-time curve (AUC) for both tests and a significant correlation with AUC. The AUC was similar in HI and NI ponies after i.v. dextrose, indicating similar pancreatic capacity for both groups. However, for oral dextrose, the AUC and the AUC were markedly higher ( < 0.05) in the HI ponies, indicating a greater secretion rate of these peptides. Slower insulin clearance might have also contributed to the larger AUC in HI ponies, but this hypothesis requires further investigation with specific measures of hepatic insulin clearance.
Jiang, Zhinong; Mao, Zhiwei; Wang, Zijia; Zhang, Jinjie
2017-12-15
Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.
NASA Technical Reports Server (NTRS)
Moore, C. S.; Collins, J. H. Jr
1932-01-01
The clearance distribution in a precombustion chamber cylinder head was varied so that for a constant compression ratio of 13.5 the spherical auxiliary chambers contained 20, 35, 50, and 70 per cent of the total clearance volume. Each chamber was connected to the cylinder by a single circular passage, flared at both ends, and of a cross-sectional area proportional to the chamber volume, thereby giving the same calculated air-flow velocity through each passage. Results of engine-performance tests are presented with variations of power, fuel consumption, explosion pressure, rate of pressure rise, ignition lag, heat loss to the cooling water, and motoring characteristics. For good performance the minimum auxiliary chamber volume, with the cylinder head design used, was 35 per cent of the total clearance volume; for larger volumes the performance improves but slightly. With the auxiliary chamber that contained 35 percent of the clearance volume there were obtained the lowest explosion pressures, medium rates of pressure rise, and slightly less than the maximum power. For all clearance distributions an increase in engine speed decreased the ignition lag in seconds and increased the rate of pressure rise.
Liu, Alice; Ariel, Danit; Abbasi, Fahim; Lamendola, Cindy; Grove, Kaylene; Tomasso, Vanessa; Ochoa, Hector; Reaven, Gerald
2014-01-01
OBJECTIVE Salsalate treatment has been shown to improve glucose homeostasis, but the mechanism remains unclear. The aim of this study was to evaluate the effect of salsalate treatment on insulin action, secretion, and clearance rate in nondiabetic individuals with insulin resistance. RESEARCH DESIGN AND METHODS This was a randomized (2:1), single-blind, placebo-controlled study of salsalate (3.5 g daily for 4 weeks) in nondiabetic individuals with insulin resistance. All individuals had measurement of glucose tolerance (75-g oral glucose tolerance test), steady-state plasma glucose (SSPG; insulin suppression test), and insulin secretion and clearance rate (graded-glucose infusion test) before and after treatment. RESULTS Forty-one individuals were randomized to salsalate (n = 27) and placebo (n = 14). One individual from each group discontinued the study. Salsalate improved fasting (% mean change −7% [95% CI −10 to −14] vs. 1% [−3 to 5], P = 0.005) but not postprandial glucose concentration compared with placebo. Salsalate also lowered fasting triglyceride concentration (−25% [−34 to −15] vs. −6% [−26 to 14], P = 0.04). Salsalate had no effect on SSPG concentration or insulin secretion rate but significantly decreased insulin clearance rate compared with placebo (−23% [−30 to −16] vs. 3% [−10 to 15], P < 0.001). Salsalate was well tolerated, but four individuals needed a dose reduction due to symptoms. CONCLUSIONS Salsalate treatment in nondiabetic, insulin-resistant individuals improved fasting, but not postprandial, glucose and triglyceride concentration. These improvements were associated with a decrease in insulin clearance rate without change in insulin action or insulin secretion. PMID:24963111
78 FR 65744 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-01
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of 30 day Reporting Requirements Submitted for OMB Review... concerning this notice to: Agency Clearance Officer, Curtis Rich, Small Business Administration, 409 3rd...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Electronic manifest requirement for passengers.... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic Manifest Requirements for...
... Mutation Testing Breast Cancer Gene Expression Tests C-peptide C-Reactive Protein (CRP) CA 15-3 CA- ... Kinase (CK) Creatinine Creatinine Clearance Cryoglobulins Cyclic Citrullinated Peptide Antibody Cyclosporine Cystatin C Cystic Fibrosis (CF) Gene ...
Effects of petroleum hydrocarbons on hepatic function in the duck
Patton, J.F.; Dieter, M.P.
1980-01-01
1. The indocyanine green dye clearance test for hepatic function was determined in mallard ducks before and during the chronic ingestion (7 months) of representative paraffinic or aromatic petroleum hydrocarbons (PH).2. No mortality or visible symptoms of toxicity occured in any of the tests. Ingestion of 4000 ppm aromatic PH produced significant increases in liver (25%), plasma clearance of indocyanine green (33%) and hepatic blood flow (30%).3. Although the aromatics elicited a greater hepatic stress response than the paraffins, the ducks tolerated high concentrations of PH for extended periods.
Nečas, D; Vrbka, M; Urban, F; Gallo, J; Křupka, I; Hartl, M
2017-05-01
The aim of the present study is to provide an analysis of protein film formation in hip joint replacements considering real conformity based on in situ observation of the contact zone. The main attention is focused on the effect of implant nominal diameter, diametric clearance and material. For this purpose, a pendulum hip joint simulator equipped with electromagnetic motors enabling to apply continuous swinging flexion-extension motion was employed. The experimental configuration consists of femoral component (CoCrMo, BIOLOX®forte, BIOLOX®delta) and acetabular cup from optical glass fabricated according to the dimensions of real cups. Two nominal diameters were studied, 28 and 36mm, respectively, while different diametric clearances were considered. Initially, a static test focused on the protein adsorption onto rubbing surfaces was performed with 36mm implants. It was found that the development of adsorbed layer is much more stable in the case of metal head, indicating that the adsorption forces are stronger compared to ceramic. A consequential swinging test revealed that the fundamental parameter influencing the protein film formation is diametric clearance. Independently of implant diameter, film was much thicker when a smaller clearance was considered. An increase of implant size from 28mm to 36mm did not cause a substantial difference in film formation; however, the total film thickness was higher for smaller implant. In terms of material, metal heads formed a thicker film, while this fact can be, among others, also attributed to clearance, which is more than two times higher in the case of ceramic implant. Copyright © 2016 Elsevier Ltd. All rights reserved.
Reiss, Samantha; Buie, Larry; Adel, Nelly; Goldman, Debra A.; Devlin, Sean M.; Douer, Dan
2017-01-01
As a weak acid, methotrexate (MTX) is bound to serum albumin and has variable protein binding. The purpose of this study was to assess serum albumin’s relationship with MTX pharmacokinetics by comparing MTX clearance and toxicities between patients with normal serum albumin to those with hypoalbuminemia. This single-center retrospective study included adult patients with leukemia or lymphoma who received their first MTX at a dose ≥ 1 gram/m2. Hypoalbuminemia was defined as serum albumin ≤ 3.4 g/dL. MTX clearance was defined as the first documented time the MTX level ≤ 0.05 micromolar. Fisher’s Exact tests and Wilcoxon Rank Sum tests were used to examine differences in toxicities and Cox proportional hazards regression was used to assess relationship with time to clearance. Of 523 patients identified, 167 patients were evaluable. One hundred thirty five patients had normal serum albumin and 32 had hypoalbuminemia. Hypoalbuminemia was associated with a higher proportion of patients experiencing edema, ascites or pleural effusions (34% vs. 12% p=0.006) and the concomitant use of nephrotoxic agents (41% vs. 20% p=0.021). Hypoalbuminemia was associated with a significantly longer time to methotrexate clearance (median: 96 hours vs 72 hour p=0.004). In addition, patients with hypoalbuminemia had a higher proportion of hyperbilirubinemia and significantly longer hospitalization (median 14 days vs. 5 days p<0.001). In conclusion, hypoalbuminemia was associated with increased time to MTX clearance and increase length of hospitalization. High dose MTX is safe to administer in patients with low albumin levels, with appropriate leucovorin rescue and good supportive care. PMID:27542957
19 CFR 122.78 - Entry or withdrawal for exportation or for transportation and exportation.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic Manifest Requirements for Passengers, Crew Members, and Non...
Shvetsov, Yurii B; Hernandez, Brenda Y; McDuffie, Katharine; Wilkens, Lynne R; Zhu, Xuemei; Ning, Lily; Killeen, Jeffrey; Kamemoto, Lori; Goodman, Marc T
2009-03-01
The association of anal cancer with human papillomavirus (HPV) infection is well established; however, little is known about the epidemiology of anal HPV in healthy women. We investigated patterns of duration and clearance of anal HPV infection in a cohort of healthy women in Hawaii. Viral and nonviral determinants of anal HPV clearance were examined in a longitudinal cohort study of 431 sexually active women. At baseline and at 4-month intervals, interviews were conducted and cervical and anal cell specimens were obtained for detection of HPV DNA. Of the 431 women, 50% experienced a total of 414 incident anal HPV infections, reported at 1 clinic visits from baseline through a follow-up period of average duration of 1.2 years. Of these infections, 58% cleared during follow-up. The clearance rate for a high-risk anal infection was 9.2 per 100 woman-months (95% confidence interval [CI], 6.9-11.9 per 100 woman-months), with a median duration of 150 days (95% CI, 132-243 days). The slowest clearing high-risk HPV types were HPV-59 (median clearance time, 350 days) and HPV-58 (median clearance time, 252 days). The median clearance times for HPV-16 and HPV-18, the predominant types associated with anal cancer, were 132 days and 212 days, respectively. Nonviral factors that delayed clearance of anal HPV included douching, long-term tobacco smoking, and anal sex. The majority of anal HPV infections resolve in a relatively short time. Although anal HPV is commonly acquired in healthy women, its rapid clearance suggests limited efficacy of HPV testing as an anal cancer screening tool.
Bumbaca Yadav, Daniela; Sharma, Vikas K.; Boswell, Charles Andrew; Hotzel, Isidro; Tesar, Devin; Shang, Yonglei; Ying, Yong; Fischer, Saloumeh K.; Grogan, Jane L.; Chiang, Eugene Y.; Urban, Konnie; Ulufatu, Sheila; Khawli, Leslie A.; Prabhu, Saileta; Joseph, Sean; Kelley, Robert F.
2015-01-01
The pharmacokinetic (PK) behavior of monoclonal antibodies in cynomolgus monkeys (cynos) is generally translatable to that in humans. Unfortunately, about 39% of the antibodies evaluated for PKs in cynos have fast nonspecific (or non-target-mediated) clearance (in-house data). An empirical model relating variable region (Fv) charge and hydrophobicity to cyno nonspecific clearance was developed to gauge the risk an antibody would have for fast nonspecific clearance in the monkey. The purpose of this study was to evaluate the predictability of this empirical model on cyno nonspecific clearance with antibodies specifically engineered to have either high or low Fv charge. These amino acid changes were made in the Fv region of two test antibodies, humAb4D5-8 and anti-lymphotoxin α. The humAb4D5-8 has a typical nonspecific clearance in cynos, and by making it more positively charged, the antibody acquires fast nonspecific clearance, and making it less positively charged did not impact its clearance. Anti-lymphotoxin α has fast nonspecific clearance in cynos, and making it more positively charged caused it to clear even faster, whereas making it less positively charged caused it to clear slower and within the typical range. These trends in clearance were also observed in two other preclinical species, mice and rats. The effect of modifying Fv charge on subcutaneous bioavailability was also examined, and in general bioavailability was inversely related to the direction of the Fv charge change. Thus, modifying Fv charge appears to impact antibody PKs, and the changes tended to correlate with those predicted by the empirical model. PMID:26491012
France, CP; Li, J-X; Owens, WA; Koek, W; Toney, GM; Daws, LC
2012-01-01
Efficacy of antidepressant drugs is often limited. One of the limiting factors may be diet. This study shows that the effect of escitalopram in the forced swimming test is diminished in rats by food restriction that decreased body weight by 8%. The primary target for escitalopram is the serotonin (5-HT) transporter. Using high-speed chronoamperometry to measure 5-HT clearance in vivo in rats fed the same food restricted diet, the rate of 5-HT clearance from extracellular fluid in brain was dramatically increased. Increased 5-HT transporter function under conditions of dietary restriction might contribute to the decreased effect of escitalopram. These results suggest that diet plays an integral role in determining efficacy of antidepressant drugs, and might well generalize to other psychoactive drugs that impinge upon the 5-HT transporter. PMID:19419596
HIV Genotypic Resistance Testing
... Mutation Testing Breast Cancer Gene Expression Tests C-peptide C-Reactive Protein (CRP) CA 15-3 CA- ... Kinase (CK) Creatinine Creatinine Clearance Cryoglobulins Cyclic Citrullinated Peptide Antibody Cyclosporine Cystatin C Cystic Fibrosis (CF) Gene ...
An optical fiber bundle sensor for tip clearance and tip timing measurements in a turbine rig.
García, Iker; Beloki, Josu; Zubia, Joseba; Aldabaldetreku, Gotzon; Illarramendi, María Asunción; Jiménez, Felipe
2013-06-05
When it comes to measuring blade-tip clearance or blade-tip timing in turbines, reflective intensity-modulated optical fiber sensors overcome several traditional limitations of capacitive, inductive or discharging probe sensors. This paper presents the signals and results corresponding to the third stage of a multistage turbine rig, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on the turbine casing. To eliminate the influence of light source intensity variations and blade surface reflectivity, the sensing principle is based on the quotient of the voltages obtained from the two receiving bundle legs. A discrepancy lower than 3% with respect to a commercial sensor was observed in tip clearance measurements. Regarding tip timing measurements, the travel wave spectrum was obtained, which provides the average vibration amplitude for all blades at a particular nodal diameter. With this approach, both blade-tip timing and tip clearance measurements can be carried out simultaneously. The results obtained on the test turbine rig demonstrate the suitability and reliability of the type of sensor used, and suggest the possibility of performing these measurements in real turbines under real working conditions.
An Optical Fiber Bundle Sensor for Tip Clearance and Tip Timing Measurements in a Turbine Rig
García, Iker; Beloki, Josu; Zubia, Joseba; Aldabaldetreku, Gotzon; Illarramendi, María Asunción; Jiménez, Felipe
2013-01-01
When it comes to measuring blade-tip clearance or blade-tip timing in turbines, reflective intensity-modulated optical fiber sensors overcome several traditional limitations of capacitive, inductive or discharging probe sensors. This paper presents the signals and results corresponding to the third stage of a multistage turbine rig, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on the turbine casing. To eliminate the influence of light source intensity variations and blade surface reflectivity, the sensing principle is based on the quotient of the voltages obtained from the two receiving bundle legs. A discrepancy lower than 3% with respect to a commercial sensor was observed in tip clearance measurements. Regarding tip timing measurements, the travel wave spectrum was obtained, which provides the average vibration amplitude for all blades at a particular nodal diameter. With this approach, both blade-tip timing and tip clearance measurements can be carried out simultaneously. The results obtained on the test turbine rig demonstrate the suitability and reliability of the type of sensor used, and suggest the possibility of performing these measurements in real turbines under real working conditions. PMID:23739163
Comparison of trout hepatocytes and liver S9 fractions as in ...
Isolated hepatocytes and liver S9 fractions have been used to collect in vitro biotransformation data for fish as a means of improving modeled estimates of chemical bioaccumulation. To date, however, there have been few direct comparisons of these two methods. In the present study, cryopreserved trout hepatocytes were used to measure in vitro intrinsic clearance rates for 6 polycyclic aromatic hydrocarbons (PAHs). These rates were extrapolated to estimates of in vivo intrinsic clearance and used as inputs to a well-stirred liver model to predict hepatic clearance. Predicted rates of hepatic clearance were then evaluated by comparison to measured rates determined previously using isolated perfused livers. Hepatic clearance rates predicted using hepatocytes were in good agreement with measured values (< 2.1 fold difference for 5 of 6 compounds) under two competing binding assumptions. These findings, which may be attributed in part to high rates of PAH metabolism, are similar to those obtained previously using data from liver S9 fractions. For one compound (benzo[a]pyrene), the in vivo intrinsic clearance rate calculated using S9 data was 10-fold higher than that determined using hepatocytes, possibly due to a diffusion limitation on cellular uptake. Generally, however, there was good agreement between calculated in vivo intrinsic clearance rates obtained using either in vitro test system. These results suggest that both systems can be used to improve
Domiciliary humidification improves lung mucociliary clearance in patients with bronchiectasis.
Hasani, A; Chapman, T H; McCool, D; Smith, R E; Dilworth, J P; Agnew, J E
2008-01-01
Inspired air humidification has been reported to show some benefit in bronchiectatic patients. We have investigated the possibility that one effect might be to enhance mucociliary clearance. Such enhancement might, if it occurs, help to lessen the risks of recurrent infective episodes. Using a radioaerosol technique, we measured lung mucociliary clearance before and after 7 days of domiciliary humidification. Patients inhaled high flow saturated air at 37 degrees C via a patient-operated humidification nasal inhalation system for 3 h per day. We assessed tracheobronchial mucociliary clearance from the retention of (99m)Tc-labelled polystyrene tracer particles monitored for 6 h, with a follow-up 24-h reading. Ten out of 14 initially recruited patients (age 37-75 years; seven females) completed the study (two withdrew after their initial screening and two prior to the initial clearance test). Seven patients studied were non-smokers; three were ex-smokers (1-9 pack-years). Initial tracer radioaerosol distribution was closely similar between pre- and post-treatment. Following humidification, lung mucociliary clearance significantly improved, the area under the tracheobronchial retention curve decreased from 319 +/- 50 to 271 +/- 46%h (p < 0.07). Warm air humidification treatment improved lung mucociliary clearance in our bronchiectatic patients. Given this finding plus increasing laboratory and clinical interest in humidification mechanisms and effects, we believe further clinical trials of humidification therapy are desirable, coupled with analysis of humidification effects on mucus properties and transport.
78 FR 21002 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-08
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of 30 day Reporting Requirements Submitted for OMB Review... notice to: Agency Clearance Officer, Curtis Rich, Small Business Administration, 409 3rd Street SW., 5th...
78 FR 76378 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-17
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of 30 day reporting requirements submitted for OMB review... notice to: Agency Clearance Officer, Curtis Rich, Small Business Administration, 409 3rd Street SW., 5th...
78 FR 76886 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-19
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of 30 day reporting requirements submitted for OMB review... notice to: Agency Clearance Officer, Curtis Rich, Small Business Administration, 409 3rd Street SW., 5th...
78 FR 45592 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-29
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of 30 day reporting requirements submitted for OMB review... notice to: Agency Clearance Officer, Curtis Rich, Small Business Administration, 409 3rd Street SW., 5th...
78 FR 65744 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-01
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of 30 day Reporting Requirements Submitted for OMB Review... notice to: Agency Clearance Officer, Curtis Rich, Small Business Administration, 409 3rd Street SW., 5th...
78 FR 39820 - Reporting and Recordkeeping Requirements Under OMB Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-02
... SMALL BUSINESS ADMINISTRATION Reporting and Recordkeeping Requirements Under OMB Review AGENCY: Small Business Administration. ACTION: Notice of 30 day Reporting Requirements Submitted for OMB Review... notice to: Agency Clearance Officer, Curtis Rich, Small Business Administration, 409 3rd Street SW., 5th...
Niu, Jing; Venkatasubramanian, Raja; Vinks, Alexander A.; Sadhasivam, Senthilkumar
2016-01-01
Background Measuring fetal drug concentrations is extremely difficult in humans. We conducted a study in pregnant sheep to simultaneously describe maternal and fetal concentrations of propofol, a common intravenous anesthetic agent used in humans. Compared to inhalational anesthesia, propofol supplemented anesthesia lowered the dose of desflurane required to provide adequate uterine relaxation during open fetal surgery. This resulted in better intraoperative fetal cardiac outcome. This study describes maternal and fetal propofol pharmacokinetics (PK) using a chronically instrumented maternal-fetal sheep model. Methods Fetal and maternal blood samples were simultaneously collected from eight mid-gestational pregnant ewes during general anesthesia with propofol, remifentanil and desflurane. Nonlinear mixed-effects modeling was performed by using NONMEM software. Total body weight, gestational age and hemodynamic parameters were tested in the covariate analysis. The final model was validated by bootstrapping and visual predictive check. Results A total of 160 propofol samples were collected. A 2-compartment maternal PK model with a third fetal compartment appropriately described the data. Mean population parameter estimates for maternal propofol clearance and central volume of distribution were 4.17 L/min and 37.7 L, respectively, in a typical ewe with a median heart rate of 135 beats/min. Increase in maternal heart rate significantly correlated with increase in propofol clearance. The estimated population maternal-fetal inter-compartment clearance was 0.0138 L/min and the volume of distribution of propofol in the fetus was 0.144 L. Fetal propofol clearance was found to be almost negligible compared to maternal clearance and could not be robustly estimated. Conclusions For the first time, a maternal-fetal PK model of propofol in pregnant ewes was successfully developed. This study narrows the gap in our knowledge in maternal-fetal PK model in human. Our study confirms that maternal heart rate has an important influence on the pharmacokinetics of propofol during pregnancy. Much lower propofol concentration in the fetus compared to maternal concentrations explain limited placental transfer in in-vivo paired model, and less direct fetal cardiac depression we observed earlier with propofol supplemented inhalational anesthesia compared to higher dose inhalational anesthesia in humans and sheep. PMID:26752560
FYCO1 mediates clearance of α-synuclein aggregates through a Rab7-dependent mechanism.
Saridaki, Theodora; Nippold, Markus; Dinter, Elisabeth; Roos, Andreas; Diederichs, Leonie; Fensky, Luisa; Schulz, Jörg B; Falkenburger, Björn H
2018-05-10
Parkinson disease can be caused by mutations in the α-synuclein gene and is characterized by aggregates of α-synuclein protein. We have previously shown that overexpression of the small GTPase Rab7 can induce clearance of α-synuclein aggregates. In this study, we investigate which Rab7 effectors mediate this effect. To model Parkinson disease we expressed the pathogenic A53T mutant of α-synuclein in HEK293T cells and Drosophila melanogaster. We tested the Rab7 effectors FYVE and coiled-coil domain-containing protein 1 (FYCO1) and Rab-interacting lysosomal protein (RILP). FYCO1-EGFP decorated vesicles containing α-synuclein. RILP-EGFP also decorated vesicular structures, but they did not contain α-synuclein. FYCO1 overexpression reduced the number of cells with α-synuclein aggregates, defined as visible particles of EGFP-tagged α-synuclein, whereas RILP did not. FYCO1 but not RILP reduced the amount of α-synuclein protein as assayed by western blot, increased the disappearance of α-synuclein aggregates in time-lapse microscopy, and decreased α-synuclein-induced toxicity assayed by the Trypan blue assay. siRNA-mediated knockdown of FYCO1 but not RILP reduced Rab7 induced aggregate clearance. Collectively, these findings indicate that FYCO1 and not RILP mediates Rab7 induced aggregate clearance. The effect of FYCO1 on aggregate clearance was blocked by the dominant negative Rab7 indicating that FYCO1 requires active Rab7 to function. Electron microscopic analysis and insertion of lysosomal membranes into the plasma membrane indicate that FYCO1 could lead to secretion of α-synuclein aggregates. Extracellular α-synuclein as assayed by ELISA was, however, not increased with FYCO1. Coexpression of FYCO1 in the fly model decreased α-synuclein aggregates as shown by the filter trap assay and rescued the locomotor deficit resulting from neuronal A53T-α-synuclein expression. This latter finding confirms that a pathway involving Rab7 and FYCO1 stimulates degradation of α-synuclein and could be beneficial in patients with Parkinson disease. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Nathanson, Leslie K; O'Rourke, Nicholas A; Martin, Ian J; Fielding, George A; Cowen, Alistair E; Roberts, Roderick K; Kendall, Bradley J; Kerlin, Paul; Devereux, Benedict M
2005-08-01
Prospectively evaluate whether for patients having laparoscopic cholecystectomy with failed trans-cystic duct clearance of bile duct (BD) stones they should have laparoscopic choledochotomy or postoperative endoscopic retrograde cholangiography (ERCP). Clinical management of BD stones found at laparoscopic cholecystectomy in the last decade has focused on pre-cholecystectomy detection with ERCP clearance in those with suspected stones. This clinical algorithm successfully clears the stones in most patients, but no stones are found in 20% to 60% of patients and rare unpredictably severe ERCP morbidity can result in this group. Our initial experience of 300 consecutive patients with fluoroscopic cholangiography and intraoperative clearance demonstrated that, for the pattern of stone disease we see, 66% of patients' BD stones can be cleared via the cystic duct with dramatic reduction in morbidity compared to the 33% requiring choledochotomy or ERCP. Given the limitations of the preoperative approach to BD stone clearance, this trial was designed to explore the limitations, for patients failing laparoscopic trans-cystic clearance, of laparoscopic choledochotomy or postoperative ERCP. Across 7 metropolitan hospitals after failed trans-cystic duct clearance, patients were intraoperatively randomized to have either laparoscopic choledochotomy or postoperative ERCP. Exclusion criteria were: ERCP prior to referral for cholecystectomy, severe cholangitis or pancreatitis requiring immediate ERCP drainage, common BD diameter of less than 7 mm diameter, or if bilio-enteric drainage was required in addition to stone clearance. Drain decompression of the cleared BD was used in the presence of cholangitis, an edematous ampulla due to instrumentation or stone impaction and technical difficulties from local inflammation and fibrosis. The ERCP occurred prior to discharge from hospital. Mechanical and extracorporeal shockwave lithotripsy was available. Sphincter balloon dilation as an alternative to sphincterotomy to allow stone extraction was not used. Major endpoints for the trial were operative time, morbidity, retained stone rate, reoperation rate, and hospital stay. From June 1998 to February 2003, 372 patients with BD stones had successful trans-cystic duct clearance of stones in 286, leaving 86 patients randomized into the trial. Total operative time was 10.9 minutes longer in the choledochotomy group (158.8 minutes), with slightly shorter hospital stay 6.4 days versus 7.7 days. Bile leak occurred in 14.6% of those having choledochotomy with similar rates of pancreatitis (7.3% versus 8.8%), retained stones (2.4% versus 4.4%), reoperation (7.3% versus 6.6%), and overall morbidity (17% versus 13%). These data suggest that the majority of secondary BD stones can be diagnosed at the time of cholecystectomy and cleared trans-cystically, with those failing having either choledochotomy or postoperative ERCP. However, because of the small trial size, a significant chance exists that small differences in outcome may exist. We would avoid choledochotomy in ducts less than 7 mm measured at the time of operative cholangiogram and severely inflamed friable tissues leading to a difficult dissection. We would advocate choledochotomy as a good choice for patients after Billroth 11 gastrectomy, failed ERCP access, or where long delays would occur for patient transfer to other locations for the ERCP.
Bartolomé, Alberto; García-Aguilar, Ana; Asahara, Shun-Ichiro; Kido, Yoshiaki; Guillén, Carlos; Pajvani, Utpal B; Benito, Manuel
2017-09-11
The mechanistic target of rapamycin complex 1 (MTORC1) is a critical negative regulator of general autophagy. We hypothesized that MTORC1 may specifically regulate autophagic clearance of damaged mitochondria. To test this, we used cells lacking tuberous sclerosis complex 2 (TSC2 -/-), which show constitutive MTORC1 activation. TSC2 -/- cells show MTORC1-dependent impaired autophagic flux after chemical uncoupling of mitochondria, increased mitochondrial protein aging and accumulation of p62/SQSTM1 positive mitochondria. Mitochondrial autophagy (mitophagy) was also deficient in cells lacking TSC2, associated with altered expression of PTEN-induced kinase 1 (PINK1) and PARK2 translocation to uncoupled mitochondria, all of which were recovered by MTORC1 inhibition or expression of constitutively active FoxO1. These data prove the necessity of intact MTORC1 signaling to regulate two synergistic processes required for clearance of damaged mitochondria: 1) general autophagy initiation, and 2) PINK1/PARK2-mediated selective targeting of uncoupled mitochondria to the autophagic machinery. Copyright © 2017 American Society for Microbiology.
NASA Technical Reports Server (NTRS)
Zelenka, Richard E.
1992-01-01
Avionic systems that depend on digitized terrain elevation data for guidance generation or navigational reference require accurate absolute and relative distance measurements to the terrain, especially as they approach lower altitudes. This is particularly exacting in low-altitude helicopter missions, where aggressive terrain hugging maneuvers create minimal horizontal and vertical clearances and demand precise terrain positioning. Sole reliance on airborne precision navigation and stored terrain elevation data for above-ground-level (AGL) positioning severely limits the operational altitude of such systems. A Kalman filter is presented which blends radar altimeter returns, precision navigation, and stored terrain elevation data for AGL positioning. The filter is evaluated using low-altitude helicopter flight test data acquired over moderately rugged terrain. The proposed Kalman filter is found to remove large disparities in predicted AGL altitude (i.e., from airborne navigation and terrain elevation data) in the presence of measurement anomalies and dropouts. Previous work suggested a minimum clearance altitude of 220 ft AGL for a near-terrain guidance system; integration of a radar altimeter allows for operation of that system below 50 ft, subject to obstacle-avoidance limitations.
Medullary cystic kidney disease
... Tests that may be done include: 24-hour urine volume and electrolytes Blood urea nitrogen (BUN) Complete blood count (CBC) Creatinine blood test Creatinine clearance -- blood and urine Uric acid blood test Urine specific gravity (will ...
Highly fluorescent resorcinarene cavitand nanocapsules with efficient renal clearance
NASA Astrophysics Data System (ADS)
Mahadevan, Kalpana; Patthipati, Venkata Suresh; Han, Sangbum; Swanson, R. James; Whelan, Eoin C.; Osgood, Christopher; Balasubramanian, Ramjee
2016-08-01
Nanomaterial based imaging approaches hold substantial promise in addressing current diagnostic and therapeutic challenges. One of the key requirements for the successful clinical translation of nanomaterials is their complete clearance from the body within a reasonable time period preferably via the renal filtration route. This article describes the synthesis of highly fluorescent, water soluble, resorcinarene cavitand nanocapsules and demonstrates their effective renal clearance in mice. The synthesis and functionalization of nanocapsules was accomplished in a one-pot operation via thiol-ene reactions without involving self-assembly, sacrificial templates or emulsions. Water soluble resorcinarene cavitand nanocapsules obtained by this approach were covalently functionalized with Alexa Fluor 750. Highly fluorescent nanocapsules with hydrodynamic diameters of 122 nm and 68 nm and extinction coefficients of 1.3 × 109 M-1 cm-1 and 1.5 × 108 M-1 cm-1 respectively were prepared by varying the reaction conditions. The in vivo biodistribution and clearance of these nanocapsules in mice followed by whole-body fluorescence imaging showed that they were both cleared renally within a few hours. Given the inherent encapsulation capabilities of nanocapsules, the renal clearance demonstrated in this work opens up new opportunities for their theranostic applications especially for targeting and treating the urinary tract.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... Request; Bar Code Label Requirement for Human Drug and Biological Products AGENCY: Food and Drug... and clearance. Bar Code Label Requirement for Human Drug and Biological Products--(OMB Control Number... that required human drug product and biological product labels to have bar codes. The rule required bar...
Use of CFD Analyses to Predict Disk Friction Loss of Centrifugal Compressor Impellers
NASA Astrophysics Data System (ADS)
Cho, Leesang; Lee, Seawook; Cho, Jinsoo
To improve the total efficiency of centrifugal compressors, it is necessary to reduce disk friction loss, which is expressed as the power loss. In this study, to reduce the disk friction loss due to the effect of axial clearance and surface roughness is analyzed and methods to reduce disk friction loss are proposed. The rotating reference frame technique using a commercial CFD tool (FLUENT) is used for steady-state analysis of the centrifugal compressor. Numerical results of the CFD analysis are compared with theoretical results using established experimental empirical equations. The disk friction loss of the impeller is decreased in line with increments in axial clearance until the axial clearance between the impeller disk and the casing is smaller than the boundary layer thickness. In addition, the disk friction loss of the impeller is increased in line with the increments in surface roughness in a similar pattern as that of existing experimental empirical formulas. The disk friction loss of the impeller is more affected by the surface roughness than the change of the axial clearance. To minimize disk friction loss on the centrifugal compressor impeller, the axial clearance and the theoretical boundary layer thickness should be designed to be the same. The design of the impeller requires careful consideration in order to optimize axial clearance and minimize surface roughness.
An Investigation of Flight Deck Data Link in the Terminal Area
NASA Technical Reports Server (NTRS)
Martin, Lynne; Lozito, Sandra; Kaneshige, John; Dulchinos, Vicki; Sharma, Shivanjli
2013-01-01
The Next Generation Air Transportation System (NextGen) and Europe's Single European Sky ATM Research (SESAR) concepts require an increased use of trajectory-based operations, including extensive strategic air traffic control clearances. The clearances are lengthy and complex, which necessitate data link communications to allow for message permanence and integration into the autoflight systems (i.e., autoload capability). This paper examines the use of flight deck data link communications for strategic and tactical clearance usage in the terminal area. A human-in-the-loop simulation was conducted using a high-fidelity flight deck simulator, with ten commercial flight crews as participants. Data were collected from six flight scenarios in the San Francisco terminal airspace. The variables of interest were ATC message modality (voice v. data link), temporal quality of the message (tactical v. strategic) and message length. Dependent variables were message response times, communication clarifications, communication-related errors, and pilot workload. Response time results were longer in data link compared to voice, a finding that has been consistently revealed in a number of other simulations [1]. In addition, strategic clearances and longer messages resulted in a greater number of clarifications and errors, suggesting an increase in uncertainty of message interpretation for the flight crews when compared to tactical clearances. The implications for strategic and compound clearance usage in NextGen and SESAR are discussed
Johnson, Teresa R.; Hong, Seokmann; Van Kaer, Luc; Koezuka, Yasuhiko; Graham, Barney S.
2002-01-01
CD1d-deficient mice have normal numbers of T lymphocytes and natural killer cells but lack Vα14+ natural killer T cells. Respiratory syncytial virus (RSV) immunopathogenesis was evaluated in 129×C57BL/6, C57BL/6, and BALB/c CD1d−/− mice. CD8+ T lymphocytes were reduced in CD1d−/− mice of all strains, as shown by cell surface staining and major histocompatibility complex class I tetramer analysis, and resulted in strain-specific alterations in illness, viral clearance, and gamma interferon (IFN-γ) production. Transient activation of NK T cells in CD1d+/+ mice by α-GalCer resulted in reduced illness and delayed viral clearance. These data suggest that early IFN-γ production and efficient induction of CD8+-T-cell responses during primary RSV infection require CD1d-dependent events. We also tested the ability of α-GalCer as an adjuvant to modulate the type 2 immune responses induced by RSV glycoprotein G or formalin-inactivated RSV immunization. However, immunized CD1-deficient or α-GalCer-treated wild-type mice did not exhibit diminished disease following RSV challenge. Rather, some disease parameters, including cytokine production, eosinophilia, and viral clearance, were increased. These findings indicate that CD1d-dependent NK T cells play a role in expansion of CD8+ T cells and amplification of antiviral responses to RSV. PMID:11932395
Benincosa, Lisa; Birnböck, Herbert; Boswell, C Andrew; Bumbaca, Daniela; Cowan, Kyra J; Danilenko, Dimitry M; Daugherty, Ann L; Fielder, Paul J; Grimm, Hans Peter; Joshi, Amita; Justies, Nicole; Kolaitis, Gerry; Lewin-Koh, Nicholas; Li, Jing; McVay, Sami; O'Mahony, Jennifer; Otteneder, Michael; Pantze, Michael; Putnam, Wendy S; Qiu, Zhihua J; Ruppel, Jane; Singer, Thomas; Stauch, Oliver; Theil, Frank-Peter; Visich, Jennifer; Yang, Jihong; Ying, Yong
2012-01-01
Subcutaneous (SC) delivery is a common route of administration for therapeutic monoclonal antibodies (mAbs) with pharmacokinetic (PK)/pharmacodynamic (PD) properties requiring long-term or frequent drug administration. An ideal in vivo preclinical model for predicting human PK following SC administration may be one in which the skin and overall physiological characteristics are similar to that of humans. In this study, the PK properties of a series of therapeutic mAbs following intravenous (IV) and SC administration in Göttingen minipigs were compared with data obtained previously from humans. The present studies demonstrated: (1) minipig is predictive of human linear clearance; (2) the SC bioavailabilities in minipigs are weakly correlated with those in human; (3) minipig mAb SC absorption rates are generally higher than those in human and (4) the SC bioavailability appears to correlate with systemic clearance in minipigs. Given the important role of the neonatal Fc-receptor (FcRn) in the PK of mAbs, the in vitro binding affinities of these IgGs against porcine, human and cynomolgus monkey FcRn were tested. The result showed comparable FcRn binding affinities across species. Further, mAbs with higher isoelectric point tended to have faster systemic clearance and lower SC bioavailability in both minipig and human. Taken together, these data lend increased support for the use of the minipig as an alternative predictive model for human IV and SC PK of mAbs. PMID:22453096
Zhou, Wenjie; Wei, Xuesong; Wang, Leqin; Wu, Guangkuan
2017-05-01
Solving the static equilibrium position is one of the most important parts of dynamic coefficients calculation and further coupled calculation of rotor system. The main contribution of this study is testing the superlinear iteration convergence method-twofold secant method, for the determination of the static equilibrium position of journal bearing with finite length. Essentially, the Reynolds equation for stable motion is solved by the finite difference method and the inner pressure is obtained by the successive over-relaxation iterative method reinforced by the compound Simpson quadrature formula. The accuracy and efficiency of the twofold secant method are higher in comparison with the secant method and dichotomy. The total number of iterative steps required for the twofold secant method are about one-third of the secant method and less than one-eighth of dichotomy for the same equilibrium position. The calculations for equilibrium position and pressure distribution for different bearing length, clearance and rotating speed were done. In the results, the eccentricity presents linear inverse proportional relationship to the attitude angle. The influence of the bearing length, clearance and bearing radius on the load-carrying capacity was also investigated. The results illustrate that larger bearing length, larger radius and smaller clearance are good for the load-carrying capacity of journal bearing. The application of the twofold secant method can greatly reduce the computational time for calculation of the dynamic coefficients and dynamic characteristics of rotor-bearing system with a journal bearing of finite length.
Sriskandan, Shiranee; Ferguson, Melissa; Elliot, Victoria; Faulkner, Lee; Cohen, Jonathan
2006-07-01
Polyclonal human intravenous immunoglobulin (IVIG) has been advocated as an adjunct to therapy in severe invasive streptococcal toxic shock because of its ability to neutralize superantigen toxins. The aim of this study was to assess IVIG therapeutic efficacy in an experimental model of streptococcal toxic shock. To confirm the in vitro activity of IVIG against the Streptococcus pyogenes strain used in the study, IVIG was tested for superantigen neutralizing and bacterial opsonizing activity prior to in vivo studies. To evaluate the in vivo effects of IVIG in terms of microbiological outcome and disease severity in a superantigen-sensitive transgenic model of streptococcal shock, HLA-DQ transgenic mice were treated with IVIG either at the time of infection or after infection with S. pyogenes. Antibiotics were included in some studies. The IVIG preparation neutralized superantigenicity of S. pyogenes in vitro and enhanced bacterial killing in a whole blood assay. When given to mice at the time of S. pyogenes infection, IVIG neutralized circulating superantigens and reduced systemic inflammatory response. Remarkably, IVIG-enhanced systemic clearance of bacteria and enhanced neutrophil infiltrate into the infected tissues. However, when used in combination with penicillin and clindamycin in a delayed treatment setting, IVIG did not confer additional therapeutic benefit, in terms of inflammatory response, bacterial clearance or survival. IVIG monotherapy can confer benefit in experimental streptococcal shock, but extension of these findings to the clinical situation will require further evaluation.
Zhou, Wenjie; Wei, Xuesong; Wang, Leqin
2017-01-01
Solving the static equilibrium position is one of the most important parts of dynamic coefficients calculation and further coupled calculation of rotor system. The main contribution of this study is testing the superlinear iteration convergence method—twofold secant method, for the determination of the static equilibrium position of journal bearing with finite length. Essentially, the Reynolds equation for stable motion is solved by the finite difference method and the inner pressure is obtained by the successive over-relaxation iterative method reinforced by the compound Simpson quadrature formula. The accuracy and efficiency of the twofold secant method are higher in comparison with the secant method and dichotomy. The total number of iterative steps required for the twofold secant method are about one-third of the secant method and less than one-eighth of dichotomy for the same equilibrium position. The calculations for equilibrium position and pressure distribution for different bearing length, clearance and rotating speed were done. In the results, the eccentricity presents linear inverse proportional relationship to the attitude angle. The influence of the bearing length, clearance and bearing radius on the load-carrying capacity was also investigated. The results illustrate that larger bearing length, larger radius and smaller clearance are good for the load-carrying capacity of journal bearing. The application of the twofold secant method can greatly reduce the computational time for calculation of the dynamic coefficients and dynamic characteristics of rotor-bearing system with a journal bearing of finite length. PMID:28572997
Mobility of lightweight robots over snow
NASA Astrophysics Data System (ADS)
Lever, James H.; Shoop, Sally A.
2006-05-01
Snowfields are challenging terrain for lightweight (<50 kg) unmanned ground vehicles. Deep sinkage, high snowcompaction resistance, traction loss while turning and ingestion of snow into the drive train can cause immobility within a few meters of travel. However, for suitably designed vehicles, deep snow offers a smooth, uniform surface that can obliterate obstacles. Key requirements for good over-snow mobility are low ground pressure, large clearance relative to vehicle size and a drive system that tolerates cohesive snow. A small robot will invariably encounter deep snow relative to its ground clearance. Because a single snowstorm can easily deposit 30 cm of fresh snow, robots with ground clearance less than about 10 cm must travel over the snow rather than gain support from the underlying ground. This can be accomplished using low-pressure tracks (< 1.5 kPa). Even still, snow-compaction resistance can exceed 20% of vehicle weight. Also, despite relatively high traction coefficients for low track pressures, differential or skid steering is difficult because the outboard track can easily break traction as the vehicle attempts to turn against the snow. Short track lengths (relative to track separation) or coupled articulated robots offer steering solutions for deep snow. This paper presents preliminary guidance to design lightweight robots for good mobility over snow based on mobility theory and tests of PackBot, Talon and SnoBot, a custom-designed research robot. Because many other considerations constrain robot designs, this guidance can help with development of winterization kits to improve the over-snow performance of existing robots.
Nilaratanakul, Voraphoj; Chen, Jie; Tran, Oanh; Baxter, Victoria K; Troisi, Elizabeth M; Yeh, Jane X; Griffin, Diane E
2018-04-01
Sindbis virus (SINV) infection of neurons in the brain and spinal cord in mice provides a model system for investigating recovery from encephalomyelitis and antibody-mediated clearance of virus from the central nervous system (CNS). To determine the roles of IgM and IgG in recovery, we compared the responses of immunoglobulin-deficient activation-induced adenosine deaminase-deficient (AID -/- ), secretory IgM-deficient (sIgM -/- ), and AID -/- sIgM -/- double-knockout (DKO) mice with those of wild-type (WT) C57BL/6 mice for disease, clearance of infectious virus and viral RNA from brain and spinal cord, antibody responses, and B cell infiltration into the CNS. Because AID is essential for immunoglobulin class switch recombination and somatic hypermutation, AID -/- mice produce only germ line IgM, while sIgM -/- mice secrete IgG but no IgM and DKO mice produce no secreted immunoglobulin. After intracerebral infection with the TE strain of SINV, most mice recovered. Development of neurologic disease occurred slightly later in sIgM -/- mice, but disease severity, weight loss, and survival were similar between the groups. AID -/- mice produced high levels of SINV-specific IgM, while sIgM -/- mice produced no IgM and high levels of IgG2a compared to WT mice. All mice cleared infectious virus from the spinal cord, but DKO mice failed to clear infectious virus from brain and had higher levels of viral RNA in the CNS late after infection. The numbers of infected cells and the amount of cell death in brain were comparable. We conclude that antibody is required and that either germ line IgM or IgG is sufficient for clearance of virus from the CNS. IMPORTANCE Mosquito-borne alphaviruses that infect neurons can cause fatal encephalomyelitis. Recovery requires a mechanism for the immune system to clear virus from infected neurons without harming the infected cells. Antiviral antibody has previously been shown to be a noncytolytic means for alphavirus clearance. Antibody-secreting cells enter the nervous system after infection and produce antiviral IgM before IgG. Clinical studies of human viral encephalomyelitis suggest that prompt production of IgM is associated with recovery, but it was not known whether IgM is effective for clearance. Our studies used mice deficient in production of IgM, IgG, or both to characterize the antibody necessary for alphavirus clearance. All mice developed similar signs of neurologic disease and recovered from infection. Antibody was necessary for virus clearance from the brain, and either early germ line IgM or IgG was sufficient. These studies support the clinical observation that prompt production of antiviral antibody is a determinant of outcome. Copyright © 2018 American Society for Microbiology.
Vitamin E-coated membrane dialyzer and beta2-microglobulin removal.
Mandolfo, S; Bucci, R; Imbasciati, E
2003-12-01
This study was designed to test the removal of beta2-microglobulin (beta2M) in a vitamin E-modified membrane. We investigated in vivo the dialyzer (Excebrane, series EE, 1.8 m2) with respect to hydraulic permeability (Kuf), maximum ultrafiltration rate (UF max), sieving coefficient (Sc), and solute clearances in hemodialysis (HD) and in soft hemodiafiltration (HDF). Kuf was 18.4 ml/h/mmHg, UF max was 75 ml/min, and Sc for beta2M was 0.45. Clearance values at 400 ml/min of Qb in HD were 258 ml/min for urea, 201 ml/min for creatinine, and 135 ml/min for phosphate. In soft HDF, clearances were slightly higher. beta2M clearance was 26 ml/min in HD and 43 ml/min in soft HDF. In conclusion, Excebrane (series EE) procures a soft HDF with an amount of substitution fluid in post dilution mode of over 60 ml/min. Remarkable small solute clearances were obtained when the blood flow was raised to 400 ml/min. A significant reduction of beta2M is demonstrated by HDF.
NASA Technical Reports Server (NTRS)
Hahn, Edward C.; Hansman, R. John, Jr.
1992-01-01
An experiment to study how automation, when used in conjunction with datalink for the delivery of air traffic control (ATC) clearance amendments, affects the situational awareness of aircrews was conducted. The study was focused on the relationship of situational awareness to automated Flight Management System (FMS) programming and the readback of ATC clearances. Situational awareness was tested by issuing nominally unacceptable ATC clearances and measuring whether the error was detected by the subject pilots. The experiment also varied the mode of clearance delivery: Verbal, Textual, and Graphical. The error detection performance and pilot preference results indicate that the automated programming of the FMS may be superior to manual programming. It is believed that automated FMS programming may relieve some of the cognitive load, allowing pilots to concentrate on the strategic implications of a clearance amendment. Also, readback appears to have value, but the small sample size precludes a definite conclusion. Furthermore, because textual and graphical modes of delivery offer different but complementary advantages for cognitive processing, a combination of these modes of delivery may be advantageous in a datalink presentation.
NASA Technical Reports Server (NTRS)
Childs, D. W.; Scharrer, J. K.
1987-01-01
An experimental test facility is used to measure the leakage and rotordynamic coefficients of teeth-on-rotor and teeth-on-stator labyrinth gas seals. The test results are presented along with the theoretically predicted values for the two seal configurations at three different radial clearances and shaft speeds to 16,000 cpm. The test results show that the theory accurately predicts the cross-coupled stiffness for both seal configurations and shows improvement in the prediction of the direct damping for the teeth-on-rotor seal. The theory fails to predict a decrease in the direct damping coefficient for an increase in the radial clearance for the teeth-on-stator seal.
Friction factor data for flat plate tests of smooth and honeycomb surfaces. M.S. Thesis
NASA Technical Reports Server (NTRS)
Ha, Tae Woong
1989-01-01
Friction factors for honeycomb surfaces were measured with a flat plate tester. The flat plate test apparatus was described and a method was discussed for determining the friction factor experimentally. The friction factor model was developed for the flat plate test based on the Fanno Line Flow. The comparisons of the friction factor were plotted for smooth surfaces and six-honeycomb surfaces with three-clearances, 6.9 bar to 17.9 bar range of inlet pressures, and 5,000 to 100,000 range of the Reynolds number. The optimum geometries for the maximum friction factor were found as a function of cell width to cell depth and cell width to clearance ratios.
The Development and Implementation of the Kennedy Space Center Umbilical Clearance Tool
NASA Technical Reports Server (NTRS)
Chesnutt, David
2016-01-01
In preparation for NASAs upcoming Space Launch System program, the Kennedy Space Center is currently developing subsystems to provide fuel, purges and communications to the flight vehicle, known as umbilicals. It is vital to the crew and mission that these umbilicals release at T-0 without re-contacting the vehicle as it is accelerating from the launch pad. To help ensure this requirement is met by the program, a methodology of evaluating the moving bodies was developed and implemented into a tool using MATLAB. The tool, known as the KSC Umbilical Clearance Tool, takes a given elevation of interest and an umbilical retract profile within the plane to evaluate the clearance between the umbilical arm and thousands of independent flight vehicle drift profiles from a Monte Carlo analysis. The presentation will delve into the challenges associated with developing and implementing the tool framed in the context of evaluating the clearance for one of the SLS umbilicals.
NASA Technical Reports Server (NTRS)
Meitner, P. L.; Glassman, A. J.
1980-01-01
An off-design performance loss model for a radial turbine with pivoting, variable-area stators is developed through a combination of analytical modeling and experimental data analysis. A viscous loss model is used for the variation in stator loss with setting angle, and stator vane end-clearance leakage effects are predicted by a clearance flow model. The variation of rotor loss coefficient with stator setting angle is obtained by means of an analytical matching of experimental data for a rotor that was tested with six stators, having throat areas from 20 to 144% of the design area. An incidence loss model is selected to obtain best agreement with experimental data. The stator vane end-clearance leakage model predicts increasing mass flow and decreasing efficiency as a result of end-clearances, with changes becoming significantly larger with decreasing stator area.
Differentially regulated gene expression associated with hepatitis C virus clearance.
Grimes, Carolyn Z; Hwang, Lu-Yu; Wei, Peng; Shah, Dimpy P; Volcik, Kelly A; Brown, Eric L
2013-03-01
Human chronic hepatitis C virus (HCV) infections pose a significant public health threat, necessitating the development of novel treatments and vaccines. HCV infections range from spontaneous resolution to end-stage liver disease. Approximately 10-30% of HCV infections undergo spontaneous resolution independent of treatment by yet-to-be-defined mechanisms. These individuals test positive for anti-HCV antibodies in the absence of detectable viral serum RNA. To identify genes associated with HCV clearance, this study compared gene expression profiles between current drug users chronically infected with HCV and drug users who cleared their HCV infection. This analysis identified 91 differentially regulated (up- or downregulated by twofold or more) genes potentially associated with HCV clearance. The majority of genes identified were associated with immune function, with the remaining genes categorized either as cancer related or 'other'. Identification of factors and pathways that may influence virus clearance will be essential to the development of novel treatment strategies.
Impaired lipid clearance in patients with previous acute pancreatitis.
Guzmán, S; Nervi, F; Llanos, O; León, P; Valdivieso, V
1985-01-01
Fasting serum triglycerides were measured in 52 patients who had sustained an attack of pancreatitis (gall stone related 33, alcoholism six) at least six months earlier. Several patients (23%) had raised fasting serum triglycerides, with a type IV phenotype in all but one patient. The 40 patients with normal fasting serum triglycerides received an oral load of 100 g sunflower oil to compare their clearance of dietary triglycerides with that of a control group of 54 subjects. The clearance of ingested triglycerides was significantly impaired in the patients - irrespective of the presumed aetiological factor, or clinical condition associated with pancreatitis - compared with the clearance in controls. A triglyceride tolerance test is the only way to detect those patients in whom a future attack of pancreatitis may be precipitated by a diet rich in fat, or endogenous over production of triglycerides as after an alcoholic debauch. PMID:4029716
Banister, Carolyn E; Messersmith, Amy R; Cai, Bo; Spiryda, Lisa B; Glover, Saundra H; Pirisi, Lucia; Creek, Kim E
2015-01-01
Cervical cancer incidence and mortality rates are higher in African Americans than in European Americans (white, non-Hispanic of European ancestry). The reasons for this disparity are not known. We recruited a population-based longitudinal cohort of 326 European American and 113 African American female college freshmen in Columbia, South Carolina, to compare clearance of high-risk human papillomavirus (HR-HPV) infection between ethnicities. HPV testing and typing from samples obtained for Papanicolaou testing occurred every 6 months. African American participants had an increased risk of testing positive for HR-HPV, compared with European American participants, but the frequency of incident HPV infection was the same in African American and European American women. Thus, exposure to HPV could not explain the higher rate of HPV positivity among African American women. The time required for 50% of participants to clear HR-HPV infection was 601 days for African American women (n = 63) and 316 days for European American women (n = 178; odds ratio [OR], 1.61; 95% confidence interval [CI], 1.08-2.53). African American women were more likely than European American women to have an abnormal result of a Papanicolaou test (OR, 1.58; 95% CI, 1.05-2.39). We propose that the longer time to clearance of HR-HPV among African American women leads to increased rates of abnormal results of Papanicolaou tests and contributes to the increased rates of cervical cancer observed in African American women. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Turbine blade tip clearance measurements using skewed dual optical beams of tip timing
NASA Astrophysics Data System (ADS)
Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai
2011-12-01
Optimization and active control of the clearance between turbine blades and case of the engine is identified, especially in aerospace community, as a key technology to increase engine efficiency, reduce fuel consumption and emissions and increase service life .However, the tip clearance varies during different operating conditions. Thus a reliable non-contact and online detection system is essential and ultimately used to close the tip clearance control loop. This paper described a fiber optical clearance measuring system applying skewed dual optical beams to detect the traverse time of passing blades. Two beams were specially designed with an outward angle of 18 degree and the beam spot diameters are less than 100μm within 0-4mm working range to achieve high signal-to-noise and high sensitivity. It could be theoretically analyzed that the measuring accuracy is not compromised by degradation of signal intensity caused by any number of environmental conditions such as light source instability, contamination and blade tip imperfection. Experimental tests were undertaken to achieve a high resolution of 10µm in the rotational speed range 2000-18000RPM and a measurement accuracy of 15μm, indicating that the system is capable of providing accurate and reliable data for active clearance control (ACC).
Jiang, Zhinong; Wang, Zijia; Zhang, Jinjie
2017-01-01
Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable. PMID:29244722
76 FR 50320 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... the FRA Administrator, FRA issued revisions to the regulations governing freight power brakes and... regulatory requirements related to power brakes on freight cars as well as the recently added requirements... (ICR) that FRA will submit for clearance by OMB as required under the PRA: Title: Inspection Brake...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-08
... Flight Requirements for Crew and Space Flight Participants AGENCY: Federal Aviation Administration (FAA...-0720. Title: Human Space Flight Requirements for Crew and Space Flight Participants. Form Numbers... information collection. Background: The FAA has established requirements for human space flight of crew and...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-20
... Flight Requirements for Crew and Space Flight Participants AGENCY: Federal Aviation Administration (FAA...-0720. Title: Human Space Flight Requirements for Crew and Space Flight Participants. Form Numbers... information collection. Background: The FAA has established requirements for human space flight of crew and...
NASA Astrophysics Data System (ADS)
McKay, R. A.
1984-06-01
A 1-MW wellhead generator was tested in 1980, 1981, and 1982 by Mexico, Italy, and New Zealand at Cerro Prieto, Cesano, and Broadlands, respectively. The total flow helical screw expander portable power plant, Model 76-1, had been built for the U.S. Government and field-tested in Utah, USA, in 1978 and 1979. The expander had oversized internal clearances designed for self-cleaning operation on fluids that deposit adherent scale normally detrimental to the utiliation of liquid dominated fields. Conditions with which the expander was tested included inlet pressures of 64 to 220 psia, inlet qualities of 0% to 100%, exhaust pressures of 3.1 to 40 psia, electrial loads of idle and 110 to 933 kW, electrical frequencies of 50 and 60 Hz, male rotor speeds of 2500 to 4000 rpm, and fluid characteristics to 310,000 ppm total dissolved solids and noncondensables to 38 wt % of the vapor. Some testing was done on-grid. Typical expander isentropic efficiency was 40% to 50% with the clearances not closed, and 5 percentage points or more higher with the clearances partly closed. The expander efficiency increased approximately logarithmically with shaft power for most operations, while inlet quality, speed, and pressure ratio across the machine had only small effects. These findings are all in agreement with the Utah test results.
NASA Technical Reports Server (NTRS)
Mckay, R. A.
1984-01-01
A 1-MW wellhead generator was tested in 1980, 1981, and 1982 by Mexico, Italy, and New Zealand at Cerro Prieto, Cesano, and Broadlands, respectively. The total flow helical screw expander portable power plant, Model 76-1, had been built for the U.S. Government and field-tested in Utah, USA, in 1978 and 1979. The expander had oversized internal clearances designed for self-cleaning operation on fluids that deposit adherent scale normally detrimental to the utiliation of liquid dominated fields. Conditions with which the expander was tested included inlet pressures of 64 to 220 psia, inlet qualities of 0% to 100%, exhaust pressures of 3.1 to 40 psia, electrial loads of idle and 110 to 933 kW, electrical frequencies of 50 and 60 Hz, male rotor speeds of 2500 to 4000 rpm, and fluid characteristics to 310,000 ppm total dissolved solids and noncondensables to 38 wt % of the vapor. Some testing was done on-grid. Typical expander isentropic efficiency was 40% to 50% with the clearances not closed, and 5 percentage points or more higher with the clearances partly closed. The expander efficiency increased approximately logarithmically with shaft power for most operations, while inlet quality, speed, and pressure ratio across the machine had only small effects. These findings are all in agreement with the Utah test results.
Whirling Arm Tests on the Effect of Ground Proximity to an Airplane Wing
NASA Technical Reports Server (NTRS)
Long, M. E.
1944-01-01
This report gives the results of tests on a rectangular wing model with a 20% full spun split flap, conducted on the whirling arm at the Daniel Guggenheim Airship Institute in Akron, Ohio. The effect of a ground board on the lift and pitching moment was measured. The ground board consisted of an inclined ramp rising up in the test channel to a level floor extending for some distance parallel to the model path. The path of the wing model with respect to the ground board accordingly represented with comparative exactness an airplane coming in for a landing. The ground clearances over the level portion of the board varied from 0 6 to 1,6 chord lengths. Results are given in the standard dimensionless coefficients plotted versus angle of attack for a particular ground clearance. The effect of the ground board is to increase the lift coefficient for a given angle of attack all the way up the stall. The magnitude of the increase varies both with the ground clearance and the angle of attack. The effect on the pitching moment coefficient is not so readily apparent due to experimental difficulties but, in general, the diving moment increases over the ground board. This effect is apparent principally at the high angles of attack. An exception to this effect occurs with flaps deflected at the lowest ground clearance (0.6 chords). Here the diving moment decreases over the ground board.
Controls Considerations for Turbine Active Clearance Control
NASA Technical Reports Server (NTRS)
Melcher, Kevin J.
2004-01-01
This presentation discusses active control of turbine tip clearance from a control systems perspective. It is a subset of charts that were presented at the 2003 meeting of the International Society of Air Breathing Engines which was held August 31 through September 5 in Cleveland, Ohio. The associated reference paper is cited at the end of the presentation. The presentation describes active tip clearance control research being conducted by NASA to improve turbine engine systems. The target application for this effort is commercial aircraft engines. However, it is believed that the technologies developed as part of this research will benefit a broad spectrum of current and future turbomachinery. The first part of the presentation discusses the concept of tip clearance, problems associated with it, and the benefits of controlling it. It lays out a framework for implementing tip clearance controls that enables the implementation to progress from purely analytical to hardware-in-the-loop to fully experimental. And it briefly discusses how the technologies developed will be married to the previously described ACC Test Rig for hardware-in-the-loop demonstrations. The final portion of the presentation, describes one of the key technologies in some detail by presenting equations and results for a functional dynamic model of the tip clearance phenomena. As shown, the model exhibits many of the clearance dynamics found in commercial gas turbine engines. However, initial attempts to validate the model identified limitations that are being addressed to make the model more realistic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mortimer, P.S.; Simmonds, R.; Rezvani, M.
1990-12-01
The measurement of skin lymph flow was investigated using an isotope clearance technique (ICT). Multiple lymph flow determinations were undertaken in the skin of anaesthetized large white pigs to test for reproducibility, ascertain the most suitable tracer, study the influence of injection dynamics, and observe the effect of massage as a stimulus to lymph flow. Blood clearance of tracer was also investigated. Results demonstrated that lymphatic clearance is a monoexponential function with good reproducibility under controlled laboratory conditions. 99mTc-colloid (TCK17 Cis) compared favorably with 131I-human serum albumin as a tracer and both performed better than colloid gold (198Au). Lymph flowmore » was significantly faster in one pig than in the other. No difference existed between left and right sides or between caudal and rostral sites on each flank, but clearance was significantly slower in thigh than flank skin. Sub-epidermal injections cleared faster and more consistently than either deep or subcutaneous injections. Neither injection volume nor needle tract backflow of tracer influenced results, but local massage significantly enhanced clearance. Escape of 99mTc-colloid by the blood was negligible. These results indicate that skin lymph flow can be reliably measured when conditions are controlled. Extrinsic factors such as massage strongly influence lymph flow. Greater sensitivity in detecting degrees of lymphatic insufficiency may be achieved if a standardized stimulus to lymph flow is administered during isotope clearance measurement.« less
Impact of food on hepatic clearance of patients after endoscopic sphincterotomy.
Chan, Hoi-Hung; Lai, Kwok-Hung; Lin, Chiun-Ku; Tsai, Wei-Lun; Peng, Nan-Jing; Hsu, Ping-I; Lo, Gin-Ho; Wei, Min-Ching; Wang, E-Ming; Chang, Hsueh-Wen
2009-01-01
The recurrence rate of common bile duct stones (CBDS) is around 3-21% after treatment by endoscopic sphincterotomy (ES). Fatty meal has been shown to improve hepatic clearance in both patients with intact gallbladder and post-cholecystectomy after ES. This study tested the effects of different kinds of food on hepatic clearance by using quantitative cholescintigraphy (QC) in patients after ES. Forty-seven patients after ES with abnormal QC were enrolled in our study. Complete ablation of sphincter function was confirmed by sphincter of Oddi manometry. Fasting QC was done in every patient shortly after normalization of liver function, and then followed with low-fat and fatty-meal QC. Each of the 47 subjects was observed for the effect on hepatic clearance at 3 different levels of treatments (diets and fasting). Additionally, possible factors responsible for recurrent CBDS were investigated by means of logistic regression. Both fatty and low-fat meals could significantly improve hepatic clearance compared with fasting in most patients after ES. But the response to food types was individualized. All patients tolerated the meals well. There was no significant relationship between the recurrence of CBDS and sex, age, intact gallbladder and presence of juxtapapillary diverticulum, CBD size, and improvement in hepatic clearance (> or = 5%) by food. Both fatty and low-fat meals improved hepatic clearance in most of the patients with CBDS after ES, but the response to meals was individualized. Therefore, there is no need to restrict the amount of fat intake for patients who have undergone ES.
Evaluating activation of the shielding walls of a treatment room using the Monte Carlo method
NASA Astrophysics Data System (ADS)
Lee, D.-Y.; Kim, J.-H.
2018-05-01
This study investigates the radiation activation process in a medical linear accelerator, which creates a photon beam with the energy acquired from accelerated electrons. The concrete shielding walls used in conjunction with a medical linear accelerator occupy the largest portion of facility decommissioning costs. Therefore, to evaluate the activation of the shielding wall, this study simulated the operation of a linear accelerator with high-energy photon beams (10, 15, and 20 MV). The results of the simulations showed that the high-energy photon beams produced a large number of neutrons in the areas around the linear accelerator head. Several radionuclides were identified, and their half-lives and radioactivity levels were calculated. Half-lives ranged from 2.62 hours to 3.68E+06 years, and the radioactivity levels of most of the radionuclides were found to satisfy their respective clearance requirements. These results indicate that photon beams of 15 MV or lower satisfy the clearance requirements for decommissioning a linear accelerator facility, whereas those of 20 MV or higher lie partially above the regulatory clearance levels.
Selective clearance of aberrant tau proteins and rescue of neurotoxicity by transcription factor EB.
Polito, Vinicia A; Li, Hongmei; Martini-Stoica, Heidi; Wang, Baiping; Yang, Li; Xu, Yin; Swartzlander, Daniel B; Palmieri, Michela; di Ronza, Alberto; Lee, Virginia M-Y; Sardiello, Marco; Ballabio, Andrea; Zheng, Hui
2014-09-01
Accumulating evidence implicates impairment of the autophagy-lysosome pathway in Alzheimer's disease (AD). Recently discovered, transcription factor EB (TFEB) is a molecule shown to play central roles in cellular degradative processes. Here we investigate the role of TFEB in AD mouse models. In this study, we demonstrate that TFEB effectively reduces neurofibrillary tangle pathology and rescues behavioral and synaptic deficits and neurodegeneration in the rTg4510 mouse model of tauopathy with no detectable adverse effects when expressed in wild-type mice. TFEB specifically targets hyperphosphorylated and misfolded Tau species present in both soluble and aggregated fractions while leaving normal Tau intact. We provide in vitro evidence that this effect requires lysosomal activity and we identify phosphatase and tensin homolog (PTEN) as a direct target of TFEB that is required for TFEB-dependent aberrant Tau clearance. The specificity and efficacy of TFEB in mediating the clearance of toxic Tau species makes it an attractive therapeutic target for treating diseases of tauopathy including AD. © 2014 The Authors. Published under the terms of the CC BY 4.0 license.
NASA Technical Reports Server (NTRS)
Sherriff, Abigail
2015-01-01
The Field Test study is currently in full swing, preceded by the successful completion of the Pilot Field Test study that paved the way for collecting data on the astronauts in the medical tent in Kazakhstan. Abigail Sherriff worked alongside Logan Dobbe on one Field Test aspect to determine foot clearance over obstacles (5cm, 10cm, and 15cm) using APDM Inc. Internal Measurement Units (IMU) worn by the astronauts. They created a program to accurately calculate foot clearance using the accelerometer, magnetometer, and gyroscope data with the IMUs attached to the top of the shoes. To validate the functionality of their program, they completed a successful study on test subjects performing various tasks in an optical motion studio, considered a gold standard in biomechanics research. Future work will include further validation and expanding the program to include other analyses.
Profile of a cell test database and a corresponding reliability database
NASA Technical Reports Server (NTRS)
Brearley, George R.; Klein, Glenn C.
1992-01-01
The development of computerized control, and data retrieval for aerospace cell testing affords an excellent opportunity to incorporate three specific concepts to both manage the test area and to track product performance on a real-time basis. The adoption and incorporation of precepts fostered by this total quality management (TQM) initiative are critical to us for retaining control of our business while substantially reducing the separate quality control inspection activity. Test discrepancies are all 'equally bad' in cell acceptance testing because, for example, we presently do not discriminate between 1 or 25 mV for an overvoltage condition. We must take leadership in classifying such discrepancies in order to expedite their clearance and redirect our resources for prevention activities. The development and use of engineering alerts (or guardbanding) which more closely match our product capabilities and are toleranced tighter than the required customer specification are paramount to managing the test unit in order to remain both quality and cost effective.
A Near-Term Concept for Trajectory Based Operations with Air/Ground Data Link Communication
NASA Technical Reports Server (NTRS)
McNally, David; Mueller, Eric; Thipphavong, David; Paielli, Russell; Cheng, Jinn-Hwei; Lee, Chuhan; Sahlman, Scott; Walton, Joe
2010-01-01
An operating concept and required system components for trajectory-based operations with air/ground data link for today's en route and transition airspace is proposed. Controllers are fully responsible for separation as they are today, and no new aircraft equipage is required. Trajectory automation computes integrated solutions to problems like metering, weather avoidance, traffic conflicts and the desire to find and fly more time/fuel efficient flight trajectories. A common ground-based system supports all levels of aircraft equipage and performance including those equipped and not equipped for data link. User interface functions for the radar controller's display make trajectory-based clearance advisories easy to visualize, modify if necessary, and implement. Laboratory simulations (without human operators) were conducted to test integrated operation of selected system components with uncertainty modeling. Results are based on 102 hours of Fort Worth Center traffic recordings involving over 37,000 individual flights. The presence of uncertainty had a marginal effect (5%) on minimum-delay conflict resolution performance, and windfavorable routes had no effect on detection and resolution metrics. Flight plan amendments and clearances were substantially reduced compared to today s operations. Top-of-descent prediction errors are the largest cause of failure indicating that better descent predictions are needed to reliably achieve fuel-efficient descent profiles in medium to heavy traffic. Improved conflict detections for climbing flights could enable substantially more continuous climbs to cruise altitude. Unlike today s Conflict Alert, tactical automation must alert when an altitude amendment is entered, but before the aircraft starts the maneuver. In every other failure case tactical automation prevented losses of separation. A real-time prototype trajectory trajectory-automation system is running now and could be made ready for operational testing at an en route Center in 1-2 years.
Discounting the duration of bolus exposure in impedance testing underestimates acid reflux.
Vikneswaran, Namasivayam; Murray, Joseph A
2016-06-08
Combined impedance-pH testing (MII) allows for detection of reflux episodes regardless of pH. However impedance-based diagnosis of reflux may not routinely account for duration of the reflux episode. We hypothesize that impedance testing may be less sensitive than pH-testing in detecting acid reflux off therapy as a result of discounting duration of exposure. Baseline characteristics and reflux parameters of MII studies performed off-anti-secretory medications were analyzed. Studies on acid suppressive medication and those with recording times less than 20 h or low baseline impedance were excluded. A total of 73 consecutive MII studies were analyzed of which 31 MII studies had elevated acid exposure while 16 were abnormal by impedance criteria. MII testing off-therapy was more likely to be abnormal by pH criteria (percent time pH < 4) than impedance criteria (total reflux):[42 vs 22 % (p =0.02)]. Acid exposure (percent time pH < 4) identified more studies as abnormal than MII-detected acid reflux episodes [42 vs 34 % (p < 0.01)]. Mean acid clearance time (pH-detected) was significantly longer than median bolus clearance time (impedance-detected) in the total [98.7 s vs 12.6 s (p < 0.01)], upright [58.6 s vs 13.1 s (p < 0.01)], and recumbent positions [136.7 s vs 14.2 s (p < 0.01)] with the greatest difference seen in the recumbent position. The mean ratio of mean acid clearance time (pH-detected) and the median bolus clearance time (impedance-detected) was significantly higher in the recumbent position compared to the upright position [11. vs 5.3 (p = 0.01)]. Ambulatory impedance testing underestimates acid reflux compared to esophageal acid exposure by discounting the prolonged period of mucosal contact with each acid reflux episode, particularly in the recumbent position.
29 CFR 1926.403 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ready and safe operation and maintenance of such equipment. (i) Working clearances. Except as required... sufficient durability to withstand the environment involved. (h) Identification of disconnecting means and... sufficient durability to withstand the environment involved. (i) 600 Volts, nominal, or less. This paragraph...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-25
... Web Portal Requirements 45 CFR part 159; Use: In accordance with sections 1103 and 10102 of the... mandated by sections 1103 and 10102 of the Affordable Care Act. Once all of the information is collected...
NASA Technical Reports Server (NTRS)
Grant, W. L.
1969-01-01
A high-temperature statorette, consisting of an iron-27 percent cobalt magnetic lamination stack and nickel-clad silver conductors, was tested with pyrolytic boron nitride slot insulation. Temperatures were measured in each test to determine characteristics of slot linear heat conductance from statorette conductors. Testing was carried out to temperatures of approximately 1500 F in a vacuum environment of 10-8 torr. Three assemblies were built and tested, each having a different room temperature slot clearance. The final statorette assembly was subjected to a 100-hour vacuum aging test at 1400 F followed by 25 thermal cycles. Temperature data from the three assemblies showed that decreasing slot clearance and increasing compression loading did enhance heat transfer. The temperature difference between slot and lamination at 1400 F increased 4 F during the thermal aging and an additional 10 F during the 25 thermal cycles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clough, Malcolm; Jackson, Austin
2012-07-01
This investigation required the selection of a suitable cask and development of a device to hold and transport irradiated targets from a foreign nuclear reactor to the Chalk River Laboratories in Ontario, Canada. The main challenge was to design and validate a target holder to protect the irradiated HEU-Al target pencils during transit. Each of the targets was estimated to have an initial decay heat of 118 W prior to transit. As the targets have little thermal mass the potential for high temperature damage and possibly melting was high. Thus, the primary design objective was to conceive a target holdermore » to dissipate heat from the targets. Other design requirements included securing the targets during transportation and providing a simple means to load and unload the targets while submerged five metres under water. A unique target holder (patent pending) was designed and manufactured together with special purpose experimental apparatus including a representative cask. Aluminum dummy targets were fabricated to accept cartridge heaters, to simulate decay heat. Thermocouples were used to measure the temperature of the test targets and selected areas within the target holder and test cask. After obtaining test results, calculations were performed to compensate for differences between experimental and real life conditions. Taking compensation into consideration the maximum target temperature reached was 231 deg. C which was below the designated maximum of 250 deg. C. The design of the aluminum target holder also allowed generous clearance to insert and unload the targets. This clearance was designed to close up as the target holder is placed into the cavity of the transport cask. Springs served to retain and restrain the targets from movement during transportation as well as to facilitate conductive heat transfer. The target holder met the design requirements and as such provided data supporting the feasibility of transporting targets over a relatively long period of time. A suitable transport cask was selected and a device for housing irradiated targets for loading, unloading and transportation has been designed, built and validated. The device was successful in meeting all design requirements for this feasibility study. Experiments were conducted with a custom test facility to confirm that the design met the maximum temperature requirements during shipping. Results from tests showed that the peak temperature in the apparatus was 300 deg. C. By compensating for experimental considerations, such as reduced thermal conductivity of the test cask versus that of the actual cask the expected maximum target temperature reduces to 231 deg. C. This is below the designated peak value of 250 deg. C. It can therefore be concluded, based on the content of this paper and from a heat-removal standpoint, the feasibility of transporting targets from a foreign nuclear reactor to Canada is possible, although further testing with irradiated targets and a full size cask would be a recommended next step. (authors)« less
Long-term clearance from small airways in subjects with ciliary dysfunction.
Lindström, Maria; Falk, Rolf; Hjelte, Lena; Philipson, Klas; Svartengren, Magnus
2006-05-20
The objective of this study was to investigate if long-term clearance from small airways is dependent on normal ciliary function. Six young adults with primary ciliary dyskinesia (PCD) inhaled 111 Indium labelled Teflon particles of 4.2 microm geometric and 6.2 microm aerodynamic diameter with an extremely slow inhalation flow, 0.05 L/s. The inhalation method deposits particles mainly in the small conducting airways. Lung retention was measured immediately after inhalation and at four occasions up to 21 days after inhalation. Results were compared with data from ten healthy controls. For additional comparison three of the PCD subjects also inhaled the test particles with normal inhalation flow, 0.5 L/s, providing a more central deposition. The lung retention at 24 h in % of lung deposition (Ret24) was higher (p < 0.001) in the PCD subjects, 79 % (95% Confidence Interval, 67.6;90.6), compared to 49% (42.3;55.5) in the healthy controls. There was a significant clearance after 24 h both in the PCD subjects and in the healthy controls with equivalent clearance. The mean Ret24 with slow inhalation flow was 73.9 +/- 1.9% compared to 68.9 +/- 7.5% with normal inhalation flow in the three PCD subjects exposed twice. During day 7-21 the three PCD subjects exposed twice cleared 9% with normal flow, probably representing predominantly alveolar clearance, compared to 19% with slow inhalation flow, probably representing mainly small airway clearance. This study shows that despite ciliary dysfunction, clearance continues in the small airways beyond 24 h. There are apparently additional clearance mechanisms present in the small airways.
Cuddy, B G; Loegering, D J; Blumenstock, F A
1984-09-01
Previous studies have implicated a role for impaired hepatic macrophage blood clearance function in the increased susceptibility to infection caused by experimental thermal injury. The present study evaluated in vivo hepatic macrophage complement receptor clearance function as a possible factor contributing to impaired hepatic clearance after thermal injury. Rat erythrocytes treated with anti-erythrocyte serum (EA) were used as the test particle in rats. EA were rapidly removed from the circulation primarily by the liver and hepatic uptake of EA was greatly depressed in animals rendered C3 deficient by treatment with cobra venom factor. Thermal injury caused a large depression in the hepatic uptake of EA. It was shown that the depression in the binding of EA to hepatic macrophages was not due to decreased hepatic blood flow, decreased serum complement levels, or increased fluid phase C3b. Also, the depression of the hepatic uptake of EA incubated with serum prior to injection (EAC) was not different from that of EA after thermal injury. On this basis it was concluded that the impairment in binding of EA to the macrophages was at the cellular level and represented a depression in complement receptor clearance function. Additional studies showed that the injection of erythrocyte stroma, as a model of intravascular hemolysis, also depressed in vivo hepatic macrophage complement receptor clearance function. This latter finding suggests that the intravascular hemolysis caused by thermal injury may contribute to the depression of macrophage receptor function. The depression of hepatic macrophage complement receptor clearance function may contribute to the impaired bacterial clearance and increased susceptibility to infection following experimental thermal injury.
Nasal high flow clears anatomical dead space in upper airway models
Celik, Gülnaz; Feng, Sheng; Bartenstein, Peter; Meyer, Gabriele; Eickelberg, Oliver; Schmid, Otmar; Tatkov, Stanislav
2015-01-01
Recent studies showed that nasal high flow (NHF) with or without supplemental oxygen can assist ventilation of patients with chronic respiratory and sleep disorders. The hypothesis of this study was to test whether NHF can clear dead space in two different models of the upper nasal airways. The first was a simple tube model consisting of a nozzle to simulate the nasal valve area, connected to a cylindrical tube to simulate the nasal cavity. The second was a more complex anatomically representative upper airway model, constructed from segmented CT-scan images of a healthy volunteer. After filling the models with tracer gases, NHF was delivered at rates of 15, 30, and 45 l/min. The tracer gas clearance was determined using dynamic infrared CO2 spectroscopy and 81mKr-gas radioactive gamma camera imaging. There was a similar tracer-gas clearance characteristic in the tube model and the upper airway model: clearance half-times were below 1.0 s and decreased with increasing NHF rates. For both models, the anterior compartments demonstrated faster clearance levels (half-times < 0.5 s) and the posterior sections showed slower clearance (half-times < 1.0 s). Both imaging methods showed similar flow-dependent tracer-gas clearance in the models. For the anatomically based model, there was complete tracer-gas removal from the nasal cavities within 1.0 s. The level of clearance in the nasal cavities increased by 1.8 ml/s for every 1.0 l/min increase in the rate of NHF. The study has demonstrated the fast-occurring clearance of nasal cavities by NHF therapy, which is capable of reducing of dead space rebreathing. PMID:25882385
Rare versus common variants in pharmacogenetics: SLCO1B1 variation and methotrexate disposition
Ramsey, Laura B.; Bruun, Gitte H.; Yang, Wenjian; Treviño, Lisa R.; Vattathil, Selina; Scheet, Paul; Cheng, Cheng; Rosner, Gary L.; Giacomini, Kathleen M.; Fan, Yiping; Sparreboom, Alex; Mikkelsen, Torben S.; Corydon, Thomas J.; Pui, Ching-Hon; Evans, William E.; Relling, Mary V.
2012-01-01
Methotrexate is used to treat autoimmune diseases and malignancies, including acute lymphoblastic leukemia (ALL). Inter-individual variation in clearance of methotrexate results in heterogeneous systemic exposure, clinical efficacy, and toxicity. In a genome-wide association study of children with ALL, we identified SLCO1B1 as harboring multiple common polymorphisms associated with methotrexate clearance. The extent of influence of rare versus common variants on pharmacogenomic phenotypes remains largely unexplored. We tested the hypothesis that rare variants in SLCO1B1 could affect methotrexate clearance and compared the influence of common versus rare variants in addition to clinical covariates on clearance. From deep resequencing of SLCO1B1 exons in 699 children, we identified 93 SNPs, 15 of which were non-synonymous (NS). Three of these NS SNPs were common, with a minor allele frequency (MAF) >5%, one had low frequency (MAF 1%–5%), and 11 were rare (MAF <1%). NS SNPs (common or rare) predicted to be functionally damaging were more likely to be found among patients with the lowest methotrexate clearance than patients with high clearance. We verified lower function in vitro of four SLCO1B1 haplotypes that were associated with reduced methotrexate clearance. In a multivariate stepwise regression analysis adjusting for other genetic and non-genetic covariates, SLCO1B1 variants accounted for 10.7% of the population variability in clearance. Of that variability, common NS variants accounted for the majority, but rare damaging NS variants constituted 17.8% of SLCO1B1's effects (1.9% of total variation) and had larger effect sizes than common NS variants. Our results show that rare variants are likely to have an important effect on pharmacogenetic phenotypes. PMID:22147369
Unexploded Ordnance Clearance: A Coordinated Approach to Requirements and Technology Development.
1997-03-25
ID #23) Clear mines and obstacles in a 50-meter-wide lane through the surf H N N N N zone and beach in order to land Landing Craft Air Cushion (LCAC...ID #33) Clear the surf zone (SZ) and beach zone (BZ) of mines and H N L N N obstacles in order to land LCAC during amphibious assaults and...Range Clearance All areas Commercial Off The Shelf (COTS) or military adapted -equipment, EOD technicians, DoD civilians, locally hired service
Improving Store Separation Six-Degree-of-Freedom Tools (ISSSDF)
2007-01-01
the Australian Air Force. NAVAIR is in the process of preparing a flight clearance for the High Speed Anti- radiation Demonstrator ( HSAD ...program. This clearance will be prepared using the conventional tool NAVSEP. The HSAD missile, however, utilizes an autopilot to move four movable...conventional NAVSEP approach to clear the HSAD missile, it would be desirable to test the TGP and STEME codes for the same case. It would be
Robotic Range Clearance Competition (R2C2)
2011-10-01
unexploded ordnance (UXO). A large part of the debris field consists of ferrous metal objects that magnetic 39 Distribution A: Approved for public...was set at 7 degrees above horizontal based on terrain around the Base station. We used the BSUBR file for all fields except the Subsurface...and subsurface clearance test areas had numerous pieces of simulated unexploded ordinance (SUXO) buried at random locations around the field . These
... Mutation Testing Breast Cancer Gene Expression Tests C-peptide C-Reactive Protein (CRP) CA 15-3 CA- ... Kinase (CK) Creatinine Creatinine Clearance Cryoglobulins Cyclic Citrullinated Peptide Antibody Cyclosporine Cystatin C Cystic Fibrosis (CF) Gene ...
... Mutation Testing Breast Cancer Gene Expression Tests C-peptide C-Reactive Protein (CRP) CA 15-3 CA- ... Kinase (CK) Creatinine Creatinine Clearance Cryoglobulins Cyclic Citrullinated Peptide Antibody Cyclosporine Cystatin C Cystic Fibrosis (CF) Gene ...
Kuklin, Nelly A; Pancari, Gregory D; Tobery, Timothy W; Cope, Leslie; Jackson, Jesse; Gill, Charles; Overbye, Karen; Francis, Kevin P; Yu, Jun; Montgomery, Donna; Anderson, Annaliesa S; McClements, William; Jansen, Kathrin U
2003-09-01
Staphylococcal infections associated with catheter and prosthetic implants are difficult to eradicate and often lead to chronic infections. Development of novel antibacterial therapies requires simple, reliable, and relevant models for infection. Using bioluminescent Staphylococcus aureus, we have adapted the existing foreign-body and deep-wound mouse models of staphylococcal infection to allow real-time monitoring of the bacterial colonization of catheters or tissues. This approach also enables kinetic measurements of bacterial growth and clearance in each infected animal. Persistence of infection was observed throughout the course of the study until termination of the experiment at day 16 in a deep-wound model and day 21 in the foreign-body model, providing sufficient time to test the effects of antibacterial compounds. The usefulness of both animal models was assessed by using linezolid as a test compound and comparing bioluminescent measurements to bacterial counts. In the foreign-body model, a three-dose antibiotic regimen (2, 5, and 24 h after infection) resulted in a decrease in both luminescence and bacterial counts recovered from the implant compared to those of the mock-treated infected mice. In addition, linezolid treatment prevented the formation of subcutaneous abscesses, although it did not completely resolve the infection. In the thigh model, the same treatment regimen resulted in complete resolution of the luminescent signal, which correlated with clearance of the bacteria from the thighs.
Comparative study of three methods of estimation of creatinine clearance in critically ill patients.
Blasco, V; Antonini, F; Zieleskiewicz, L; Hammad, E; Albanèse, J; Martin, C; Leone, M
2014-05-01
At the bedside, the reference method for creatinine clearance determination is based on the measurement of creatinine concentrations in urine and serum (mCrCl). Several models are available to calculate the creatinine clearance from the serum creatinine concentration. This observational survey aimed at testing the hypothesis that the proposed equations are unreliable to determine accurate creatinine clearance in patients admitted to intensive care unit (ICU). Creatinine clearance was determined by the use of mCrCl. Then, we compared three equations: Cockcroft-Gault (CG), Simplified Modification of Diet in Renal Disease (MDRDs), and Chronic Kidney Disease Epidemiology (CKD-EPI) in 156 consecutive patients within the first 24hours after ICU admission. We tested the hypothesis that the three equations were equivalent. The agreement between the three equations was evaluated by linear regression and Bland and Altman analysis. Bland and Altman analysis showed similar agreement between the three equations. The biases and precisions were -4.8±51, -1.3±50, and 8.2±44 for CG, MDRDs, and CKD-EPI equations, respectively (P>0.05). The precisions were similar for the three equations (P>0.05). The percentages of outliers at ±30% were 44%, 45%, and 49% for CG, MDRDs, and CKD-EPI, respectively (P>0.05). Regarding the high percentage of outliers, the use of these equations cannot be recommended in ICU patients. Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.
Babelay, E.F.
1962-02-13
A flexible shaft coupling for operation at speeds in excess of 14,000 rpm is designed which requires no lubrication. A driving sleeve member and a driven sleeve member are placed in concentric spaced relationship. A torque force is transmitted to the driven member from the driving member through a plurality of nylon balls symmetrically disposed between the spaced sleeves. The balls extend into races and recesses within the respective sleeve members. The sleeve members have a suitable clearance therebetween and the balls have a suitable radial clearance during operation of the coupling to provide a relatively loose coupling. These clearances accommodate for both parallel and/or angular misalignments and avoid metal-tometal contact between the sleeve members during operation. Thus, no lubrication is needed, and a minimum of vibrations is transmitted between the sleeve members. (AEC)
Abdu, Aliyu; Naidoo, Sagren; Malgas, Shirin; Naicker, Jocelyn T; Paget, Graham; Naicker, Saraladevi
2015-01-01
Solute clearance measurement is an objective means of quantifying the dose of peritoneal dialysis (PD). Despite continued debate on the interpretation and precise prognostic value of small solute clearance in PD patients, guidelines based on solute clearance values are common in clinical practice. There is limited information on the solute clearance indices and PD adequacy parameters among this predominantly low socioeconomic status PD population. We investigated the solute clearance among continuous ambulatory peritoneal dialysis (CAPD) patients at the Charlotte Maxeke Johannesburg Academic Hospital and its relationship with other parameters of PD adequacy. Seventy patients on CAPD were studied in this cross-sectional study. Solute clearance was assessed using urea clearance (Kt/V). Linear regression analysis was used to determine factors associated with solute clearance, while analysis of variance was used to test the influence of weekly Kt/V on blood pressure (BP), hemoglobin (Hb) and other biochemical parameters. The mean age of the study population was 37.9 ± 12.4 years, 43% were females and 86% were black Africans. The mean duration on CAPD was 19.7 ± 20.8 months. Mean systolic and diastolic BP were 144 ± 28 and 92 ± 17 mm Hg, respectively. The mean Hb was 11.1 ± 2.2 g/dL and the mean weekly Kt/V was 1.7 ± 0.3. Factors like systolic BP, Hb level, serum levels of cholesterol, calcium, phosphate, parathyroid hormone and albumin were not significantly associated with the weekly Kt/V. We conclude that the dose of PD received by the majority of our patients in terms of the weekly Kt/V is within the recommended values and that this finding is significant considering the low socioeconomic background of our patients. There is no significant association between Kt/V and other indices of dialysis adequacy.
Nirmala, Svsg; Quadar, Mohammed Akhil; Veluru, Sindhuri
2016-01-01
Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate), filled (wafer and fruit and nuts chocolate), and candy (hard milk and mango-flavored candy) groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P < 0.05). Dark chocolate had a high fall in pH and milk chocolate had low salivary sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.
16 CFR 1512.17 - Other requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Other requirements. 1512.17 Section 1512.17 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS... the ground plane. (d) Toe clearance. Bicycles not equipped with positive foot-retaining devices (such...
Code of Federal Regulations, 2012 CFR
2012-04-01
... Record locator, if available; (xv) International Air Transport Association (IATA) departure port code... authorized by law. (f) Master crew member and non-crew member lists. Air carriers subject to the requirements... THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart...
Code of Federal Regulations, 2013 CFR
2013-04-01
... Record locator, if available; (xv) International Air Transport Association (IATA) departure port code... authorized by law. (f) Master crew member and non-crew member lists. Air carriers subject to the requirements... THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart...
Code of Federal Regulations, 2011 CFR
2011-04-01
... Record locator, if available; (xv) International Air Transport Association (IATA) departure port code... authorized by law. (f) Master crew member and non-crew member lists. Air carriers subject to the requirements... THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart...
Fernandez-Prado, Raul; Castillo-Rodriguez, Esmeralda; Velez-Arribas, Fernando Javier; Gracia-Iguacel, Carolina; Ortiz, Alberto
2016-12-01
Direct oral anticoagulants (DOACs) may require dose reduction or avoidance when glomerular filtration rate is low. However, glomerular filtration rate is not usually measured in routine clinical practice. Rather, equations that incorporate different variables use serum creatinine to estimate either creatinine clearance in mL/min or glomerular filtration rate in mL/min/1.73 m 2 . The Cockcroft-Gault equation estimates creatinine clearance and incorporates weight into the equation. By contrast, the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations estimate glomerular filtration rate and incorporate ethnicity but not weight. As a result, an individual patient may have very different renal function estimates, depending on the equation used. We now highlight these differences and discuss the impact on routine clinical care for anticoagulation to prevent embolization in atrial fibrillation. Pivotal DOAC clinical trials used creatinine clearance as a criterion for patient enrollment, and dose adjustment and Federal Drug Administration recommendations are based on creatinine clearance. However, clinical biochemistry laboratories provide CKD-EPI glomerular filtration rate estimations, resulting in discrepancies between clinical trial and routine use of the drugs. Copyright © 2016 Elsevier Inc. All rights reserved.
The Role of Infected Cell Proliferation in the Clearance of Acute HBV Infection in Humans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goyal, Ashish; Ribeiro, Ruy Miguel; Perelson, Alan S.
Around 90–95% of hepatitis B virus (HBV) infected adults do not progress to the chronic phase and, instead, recover naturally. The strengths of the cytolytic and non-cytolytic immune responses are key players that decide the fate of acute HBV infection. In addition, it has been hypothesized that proliferation of infected cells resulting in uninfected progeny and/or cytokine-mediated degradation of covalently closed circular DNA (cccDNA) leading to the cure of infected cells are two major mechanisms assisting the adaptive immune response in the clearance of acute HBV infection in humans. We employed fitting of mathematical models to human acute infection datamore » together with physiological constraints to investigate the role of these hypothesized mechanisms in the clearance of infection. Results suggest that cellular proliferation of infected cells resulting in two uninfected cells is required to minimize the destruction of the liver during the clearance of acute HBV infection. In contrast, we find that a cytokine-mediated cure of infected cells alone is insufficient to clear acute HBV infection. Lastly, our modeling indicates that HBV clearance without lethal loss of liver mass is associated with the production of two uninfected cells upon proliferation of an infected cell.« less
The Role of Infected Cell Proliferation in the Clearance of Acute HBV Infection in Humans
Goyal, Ashish; Ribeiro, Ruy Miguel; Perelson, Alan S.
2017-11-18
Around 90–95% of hepatitis B virus (HBV) infected adults do not progress to the chronic phase and, instead, recover naturally. The strengths of the cytolytic and non-cytolytic immune responses are key players that decide the fate of acute HBV infection. In addition, it has been hypothesized that proliferation of infected cells resulting in uninfected progeny and/or cytokine-mediated degradation of covalently closed circular DNA (cccDNA) leading to the cure of infected cells are two major mechanisms assisting the adaptive immune response in the clearance of acute HBV infection in humans. We employed fitting of mathematical models to human acute infection datamore » together with physiological constraints to investigate the role of these hypothesized mechanisms in the clearance of infection. Results suggest that cellular proliferation of infected cells resulting in two uninfected cells is required to minimize the destruction of the liver during the clearance of acute HBV infection. In contrast, we find that a cytokine-mediated cure of infected cells alone is insufficient to clear acute HBV infection. Lastly, our modeling indicates that HBV clearance without lethal loss of liver mass is associated with the production of two uninfected cells upon proliferation of an infected cell.« less
Renal ultrafiltration changes induced by focused US.
Fischer, Krisztina; McDannold, Nathan J; Zhang, Yongzhi; Kardos, Magdolna; Szabo, Andras; Szabo, Antal; Reusz, Gyorgy S; Jolesz, Ferenc A
2009-12-01
To determine if focused ultrasonography (US) combined with a diagnostic microbubble-based US contrast agent can be used to modulate glomerular ultrafiltration and size selectivity. The experiments were approved by the animal care committee. The left kidney of 17 healthy rabbits was sonicated by using a 260-kHz focused US transducer in the presence of a microbubble-based US contrast agent. The right kidney served as the control. Three acoustic power levels were applied: 0.4 W (six rabbits), 0.9 W (six rabbits), and 1.7 W (five rabbits). Three rabbits were not treated with focused US and served as control animals. The authors evaluated changes in glomerular size selectivity by measuring the clearance rates of 3000- and 70,000-Da fluorescence-neutral dextrans. The creatinine clearance was calculated for estimation of the glomerular filtration rate. The urinary protein-creatinine ratio was monitored during the experiments. The authors assessed tubular function by evaluating the fractional sodium excretion, tubular reabsorption of phosphate, and gamma-glutamyltransferase-creatinine ratio. Whole-kidney histologic analysis was performed. For each measurement, the values obtained before and after sonication were compared by using the paired t test. Significant (P < .05) increases in the relative (ratio of treated kidney value/nontreated kidney value) clearance of small- and large-molecule agents and the urine flow rates that resulted from the focused US treatments were observed. Overall, 1.23-, 1.23-, 1.61-, and 1.47-fold enhancement of creatinine clearance, 3000-Da dextran clearance, 70 000-Da dextran clearance, and urine flow rate, respectively, were observed. Focal tubular hemorrhage and transient functional tubular alterations were observed at only the highest (1.7-W) acoustic power level tested. Glomerular ultrafiltration and size selectivity can be temporarily modified with simultaneous application of US and microbubbles. This method could offer new opportunities for treatment of renal disease.
Napoli, Pietro Emanuele; Coronella, Franco; Satta, Giovanni Maria; Fossarello, Maurizio
2014-01-01
The aim of this work was to gather preliminary data in different conditions of healthy eyes, aqueous tear deficient dry eyes, obstructive meibomian gland disease (MGD) and non-obvious obstructive MGD (NOMGD) individuals, using a new, contrast-enhanced optical coherence tomography (OCT) imaging method to evaluate the clearance of lipids in human tears. Eighty-two adult patients presenting with complaints of ocular irritation were studied for abnormalities of the ocular surface and classified as healthy (n = 21), aqueous tear deficient dry eyes (n = 20), obstructive MGD (n = 15) and NOMGD (n = 26) individuals. A lipid-based tracer, containing an oil-in-water emulsion, was used to obtain an enhanced OCT imaging of the lower tear meniscus. After instillation, a dramatic initial increase of reflectivity of the lower tear meniscus was detected by OCT, followed by a decay back to baseline values over time. Based on this finding, the clearance of lipids was measured in real-time by Fourier-domain anterior segment OCT. The differences in the clearance of lipids among the four groups as well as the correlations between symptom questionnaire score, standardized visual scale test, fluorescein break-up time, ocular surface fluorescein staining score, Schirmer I test scores were found to be statistically significant. The individual areas under the curve of the clearance of lipids calculated by the receiver operating characteristic curve technique ranged from 0.66 to 0.98, suggesting reliable sensitivity and specificity of lipid-enhanced OCT imaging. This new technique of contrast-enhanced OCT imaging of the tear film following lipid-based tracer instillation provides a measure of the clearance of lipids. The quantitative values found are in agreement with other methods of evaluation of the lacrimal system. An improvement of the clinician's ability in the diagnosis and understanding of abnormalities of the ocular surface may be achieved by this simple approach.
Hu, X Q; Wood, R J K; Taylor, A; Tuke, M A
2011-11-01
Clearance is one of the most influential parameters on the tribological performance of metal-on-metal (MOM) hip joints and its selection is a subject of considerable debate. The objective of this paper is to study the lubrication behaviour of different clearances for MOM hip joints within the range of human physiological and pathological fluid viscosities. The frictional torques developed by MOM hip joints with a 50 mm diameter were measured for both virgin surfaces and during a wear simulator test. Joints were manufactured with three different diametral clearances: 20, 100, and 200 microm. The fluid used for the friction measurements which contained different ratios of 25 percent newborn calf serum and carboxymethyl cellulose (CMC) with the obtained viscosities values ranging from 0.001 to 0.71 Pa s. The obtained results indicate that the frictional torque for the 20 microm clearance joint remains high over the whole range of the viscosity values. The frictional torque of the 100 microm clearance joint was low for the very low viscosity (0.001 Pa s) lubricant, but increased with increasing viscosity value. The frictional torque of the 200 microm clearance joint was high at very low viscosity levels, however, it reduced with increasing viscosity. It is concluded that a smaller clearance level can enhance the formation of an elastohydrodynamic lubrication (EHL) film, but this is at the cost of preventing fluid recovery between the bearing surfaces during the unloaded phase of walking. Larger clearance bearings allow a better recovery of lubricant during the unloaded phase, which is necessary for higher viscosity lubricants. The selection of the clearance value should therefore consider both the formation of the EHL film and the fluid recovery as a function of the physiological viscosity in order to get an optimal tribological performance for MOM hip joints. The application of either 25 per cent bovine serum or water in existing in vitro tribological study should also be revised to consider the relevance of clinic synovial fluid viscosities and to avoid possible misleading results.
Alcohol consumption decreases lactate clearance in acutely injured patients☆
Dezman, Zachary D.W.; Comer, Angela C.; Narayan, Mayur; Scalea, Thomas M.; Hirshon, Jon Mark; Smith, Gordon S.
2017-01-01
Introduction Alcohol, a common risk factor for injury, has direct toxic effects on the liver. The use of lactate clearance has been well described as an indicator of the adequacy of resuscitation in injured patients. We investigated whether acutely injured patients with positive blood alcohol content (+BAC) had less lactate clearance than sober patients. Methods We conducted a retrospective cohort study of acutely injured patients treated at an urban Level 1 trauma centre between January 2010 and December 2012. Blood alcohol and venous lactate levels were measured on all patients at the time of arrival. Study subjects were patients transported directly from the scene of injury, who had an elevated lactate concentration on arrival (≥3.0 mmol/L) and at least one subsequent lactate measurement within 24 h after admission. Lactate clearance ([Lactate1 − Lactate2]/Lactate1) was calculated for all patients. Chi-squared tests were used to compare values from sober and intoxicated subjects. Lactate clearance was plotted against alcohol levels and stratified by age and Injury Severity Score (ISS). Results Serial lactate concentration measurements were obtained in 3910 patients; 1674 of them had +BAC. Patients with +BAC were younger (mean age: 36.6 [SD 14.7] vs 41.0 [SD 19.9] years [p = 0.0001]), were more often male (83.4% vs 75.9% [p = 0.0001]), had more minor injuries (ISS < 9) (33.8% vs 27.1% [p = 0.0001]), had a lower in-hospital mortality rate (1.4% vs 3.9% [p = 0.0001]), but also had lower average lactate clearance (37.8% vs 47.6% [p = 0.0001]). The lactate clearance of the sober patients (47.6 [SD 33.5]) was twice that of those with +BAC >400 (23.5 [SD 6.5]). Lactate clearance decreased with increasing BAC irrespective of age and ISS. Conclusions In a large group of acutely injured patients, a dose-dependent decrease in lactate clearance was seen in those with elevated BAC. This relationship will cause a falsely elevated lactate reading or prolong lactate clearance and should be taken into account when evaluating patients with +BAC. PMID:27025567
Yang, Danlin; Giragossian, Craig; Castellano, Steven; Lasaro, Marcio; Xiao, Haiguang; Saraf, Himanshu; Hess Kenny, Cynthia; Rybina, Irina; Huang, Zhong-Fu; Ahlberg, Jennifer; Bigwarfe, Tammy; Myzithras, Maria; Waltz, Erica; Roberts, Simon; Kroe-Barrett, Rachel; Singh, Sanjaya
2017-10-01
Antibodies with pH-dependent binding to both target antigens and neonatal Fc receptor (FcRn) provide an alternative tool to conventional neutralizing antibodies, particularly for therapies where reduction in antigen level is challenging due to high target burden. However, the requirements for optimal binding kinetic framework and extent of pH dependence for these antibodies to maximize target clearance from circulation are not well understood. We have identified a series of naturally-occurring high affinity antibodies with pH-dependent target binding properties. By in vivo studies in cynomolgus monkeys, we show that pH-dependent binding to the target alone is not sufficient for effective target removal from circulation, but requires Fc mutations that increase antibody binding to FcRn. Affinity-enhanced pH-dependent FcRn binding that is double-digit nM at pH 7.4 and single-digit nM at pH 6 achieved maximal target reduction when combined with similar target binding affinities in reverse pH directions. Sustained target clearance below the baseline level was achieved 3 weeks after single-dose administration at 1.5 mg/kg. Using the experimentally derived mechanistic model, we demonstrate the essential kinetic interplay between target turnover and antibody pH-dependent binding during the FcRn recycling, and identify the key components for achieving maximal target clearance. These results bridge the demand for improved patient dosing convenience with the "know-how" of therapeutic modality by design.
Update on results of SPRE testing at NASA Lewis
NASA Technical Reports Server (NTRS)
Cairelli, James E.; Swec, Diane M.; Wong, Wayne A.; Doeberling, Thomas J.; Madi, Frank J.
1991-01-01
The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigated the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The impact of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance tests results with HFAST code predictions show good agreement for PV power, but show poor agreement for PV efficiency. Correlations are presented relating the piston midstroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.
Update on results of SPRE testing at NASA Lewis
NASA Technical Reports Server (NTRS)
Cairelli, James E.; Swec, Diane M.; Wong, Wayne A.; Doeberling, Thomas J.; Madi, Frank J.
1991-01-01
The Space Power Research Engine (SPRE), a free-piston Stirling engine with a linear alternator, is being tested at NASA Lewis Research Center as part of the Civilian Space Technology Initiative (CSTI) as a candidate for high capacity space power. Results are presented from recent SPRE tests designed to investigate the effects of variation in the displacer seal clearance and piston centering port area on engine performance and dynamics. The effects of these variations on PV power and efficiency are presented. Comparisons of the displacer seal clearance test results with HFAST code predictions show good agreement for PV power but poor agreement for PV efficiency. Correlations are presented relating the piston mid-stroke position to the dynamic Delta P across the piston and the centering port area. Test results indicate that a modest improvement in PV power and efficiency may be realized with a reduction in piston centering port area.
Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts
NASA Technical Reports Server (NTRS)
Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.; Erker, Arthur H.
2004-01-01
The objectives of the research presented in this viewgraph presentation are to 1) Design a mechanical ACC system for HPT tip seal clearance management; 2) Design a test rig to evaluate ACC system concepts. We have focused our efforts on designing mechanical ACC systems that articulate the seal shroud via mechanical linkages connected to actuators that reside outside the extreme environment of the HPT. We opted for this style of design due to a lack of high temperature/low profile actuators that are presently available. We have also selected multiple hydraulic actuators for this first generation ACC system. Fuel-draulic actuators are already a well established technology.
Huang, Fang; Takala-Harrison, Shannon; Jacob, Christopher G; Liu, Hui; Sun, Xiaodong; Yang, Henglin; Nyunt, Myaing M; Adams, Matthew; Zhou, Shuisen; Xia, Zhigui; Ringwald, Pascal; Bustos, Maria Dorina; Tang, Linhua; Plowe, Christopher V
2015-11-15
Artemisinin resistance in Plasmodium falciparum has emerged in Southeast Asia and poses a threat to malaria control and elimination. Mutations in a P. falciparum gene encoding a kelch protein on chromosome 13 have been associated with delayed parasite clearance following artemisinin treatment elsewhere in the region, but not yet in China. Therapeutic efficacy studies of artesunate and dihydroartemisinin-piperaquine were conducted from 2009 to 2012 in the Yunnan Province of China near the border with Myanmar. K13 mutations were genotyped by capillary sequencing of DNA extracted from dried blood spots collected in these clinical trials and in routine surveillance. Associations between K13 mutations and delayed parasite clearance were tested using regression models. Parasite clearance half-lives were prolonged after artemisinin treatment, with 44% of infections having half-lives >5 hours (n = 109). Fourteen mutations in K13 were observed, with an overall prevalence of 47.7% (n = 329). A single mutation, F446I, predominated, with a prevalence of 36.5%. Infections with F446I were significantly associated with parasitemia on day 3 following artemisinin treatment and with longer clearance half-lives. Plasmodium falciparum infections in southern China displayed markedly delayed clearance following artemisinin treatment. F446I was the predominant K13 mutation and was associated with delayed parasite clearance. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Clearance of the cervical spine in clinically unevaluable trauma patients.
Halpern, Casey H; Milby, Andrew H; Guo, Wensheng; Schuster, James M; Gracias, Vicente H; Stein, Sherman C
2010-08-15
Meta-analytic costeffectiveness analysis. Our goal was to compare the results of different management strategies for trauma patients in whom the cervical spine was not clinically evaluable due to impaired consciousness, endotracheal intubation, or painful distracting injuries. We performed a structured literature review related to cervical spine trauma, radiographic clearance techniques (plain radiography, flexion/extension, CT, and MRI), and complications associated with semirigid collar use. Meta-analytic techniques were used to pool data from multiple sources to calculate pooled mean estimates of sensitivities and specificities of imaging techniques for cervical spinal clearance, rates of complications from various clearance strategies and from empirical use of semirigid collars. A decision analysis model was used to compare outcomes and costs among these strategies. Slightly more than 7.5% of patients who are clinically unevaluable have cervical spine injuries, and 42% of these injuries are associated with spinal instability. Sensitivity of plain radiography or fluoroscopy for spinal clearance was 57% (95% CI: 57%-60%). Sensitivities for CT and MRI alone were 83% (82%-84%) and 87% (84%-89%), respectively. Complications associated with collar use ranged from 1.3% (2 days) to 7.1% (10 days) but were usually minor and short-lived. Quadriplegia resulting from spinal instability missed by a clearance test had enormous impacts on longevity, quality of life, and costs. These impacts overshadowed the effects of prolonged collar application, even when the incidence of quadriplegia was extremely low. As currently used, neuroimaging studies for cervical spinal clearance in clinically unevaluable patients are not cost-effective compared with empirical immobilization in a semirigid collar.
Prognostic significance of blood lactate and lactate clearance in trauma patients.
Régnier, Marie-Alix; Raux, Mathieu; Le Manach, Yannick; Asencio, Yves; Gaillard, Johann; Devilliers, Catherine; Langeron, Olivier; Riou, Bruno
2012-12-01
Lactate has been shown to be a prognostic biomarker in trauma. Although lactate clearance has already been proposed as an intermediate endpoint in randomized trials, its precise role in trauma patients remains to be determined. Blood lactate levels and lactate clearance (LC) were calculated at admission and 2 and 4 h later in trauma patients. The association of initial blood lactate level and lactate clearance with mortality was tested using receiver-operating characteristics curve, logistic regression using triage scores, Trauma Related Injury Severity Score as a reference standard, and reclassification method. The authors evaluated 586 trauma patients (mean age 38±16 yr, 84% blunt and 16% penetrating, mortality 13%). Blood lactate levels at admission were elevated in 327 (56%) patients. The lactate clearance should be calculated within the first 2 h after admission as LC0-2 h was correlated with LC0-4 h (R=0.55, P<0.001) but not with LC2-4 h (R=0.04, not significant). The lactate clearance provides additional predictive information to initial blood lactate levels and triage scores and the reference score. This additional information may be summarized using a categorical approach (i.e., less than or equal to -20 %/h) in contrast to initial blood lactate. The results were comparable in patients with high (5 mM/l or more) initial blood lactate. Early (0-2 h) lactate clearance is an important and independent prognostic variable that should probably be incorporated in future decision schemes for the resuscitation of trauma patients.
Carlsen, Berit C; Wenande, Emily; Erlendsson, Andres M; Faurschou, Annesofie; Dierickx, Christine; Haedersdal, Merete
2017-01-01
Pulsed dye laser (PDL) represents the gold-standard treatment for port wine stains (PWS). However, approximately 20% of patients are poor responders and yield unsatisfactory end-results. The Alexandrite (Alex) laser may be a therapeutic alternative for selected PWS subgroups, but optimal laser parameters are not known. The aim of this study was to assess clinical PWS clearance and safety of Alex laser at a range of pulse durations. Sixteen individuals (14 previously PDL-treated) with deep red (n = 4), purple macular (n = 5) and purple hypertrophic (n = 7) PWS were included. Four side-by-side test areas were marked within each lesion. Three test areas were randomized to Alex laser at pulse durations of 3, 5, or 10 ms (8 mm spot, DCD 60/40), while the fourth was untreated. The lowest effective fluence to create purpura within the entire test spot was titrated and applied to intervention areas. Standardized clinical photographs were taken prior to, immediately after laser exposure and at 6-8 weeks follow up. Clinical PWS clearance and laser-related side effects were assessed using clinical photos. Alex laser at 3, 5, and 10 ms pulse durations demonstrated significant clearance compared to untreated controls (P < 0.001). Three milli second pulse duration exhibited improved clearance versus 5 ms (P = 0.016) and 10 ms (P = 0.004), while no difference between five and 10 ms was shown (P = 0.063). Though not significant, good responders (>50% clearance) were more likely to have purple hypertrophic PWS (5/7) compared to purple macular (2/5) and deep red lesions (1/4). Eight laser-exposed test areas (17%) developed hypopigmented atrophic scarring. Side effects tended to be more frequently observed with 5 ms (n = 4) and 10 ms (n = 3) versus 3 ms pulse duration (n = 1). Correspondingly, 3 ms was associated with a superior (n = 6) or comparable (n = 10) overall cosmetic appearance for all individuals. Alex laser at 3 ms pulse duration offers superior clinical clearance and safety compared to 5 and 10 ms, and seems best suited for purple hypertrophic PWS. Treatment should be restricted to experienced personnel due to a particularly narrow therapeutic window. Lasers Surg. Med. 49:97-103, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
30 CFR 7.307 - Static pressure test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Electric Motor Assemblies § 7.307 Static...) Permanent deformation exceeding 0.040 inches per linear foot; or (iii) Clearances, in excess of those...
30 CFR 7.307 - Static pressure test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Electric Motor Assemblies § 7.307 Static...) Permanent deformation exceeding 0.040 inches per linear foot; or (iii) Clearances, in excess of those...
30 CFR 7.307 - Static pressure test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Electric Motor Assemblies § 7.307 Static...) Permanent deformation exceeding 0.040 inches per linear foot; or (iii) Clearances, in excess of those...
30 CFR 7.307 - Static pressure test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Electric Motor Assemblies § 7.307 Static...) Permanent deformation exceeding 0.040 inches per linear foot; or (iii) Clearances, in excess of those...
76 FR 82036 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-29
... Public: Businesses. Abstract: This collection of information identifies a freight car being moved within... Information Collection Requirements (ICRs) abstracted below are being forwarded to the Office of Management... information collection requirements (ICRs) and the expected burden being submitted for clearance by OMB as...
30 CFR 822.10 - Information collection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Information collection. 822.10 Section 822.10... ALLUVIAL VALLEY FLOORS § 822.10 Information collection. The information collection requirements contained... assigned clearance number 1029-0049. The information is being collected to meet the requirements of...
30 CFR 850.10 - Information collection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Information collection. 850.10 Section 850.10... FOR CERTIFICATION OF BLASTERS § 850.10 Information collection. The information collection requirements... assigned clearance number 1029-0080. The information is being collected to meet the requirements of...
75 FR 62409 - Proposed Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-08
..., will require a Top Secret Clearance, and possible SCI Access. Responses to questions on the SSF 86A... DEPARTMENT OF HOMELAND SECURITY United States Secret Service Proposed Information Collection... request as required by the Paperwork Reduction Act of 1995. Currently, the U.S. Secret Service, within the...
30 CFR 822.10 - Information collection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Information collection. 822.10 Section 822.10... ALLUVIAL VALLEY FLOORS § 822.10 Information collection. The information collection requirements contained... assigned clearance number 1029-0049. The information is being collected to meet the requirements of...
30 CFR 850.10 - Information collection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Information collection. 850.10 Section 850.10... FOR CERTIFICATION OF BLASTERS § 850.10 Information collection. The information collection requirements... assigned clearance number 1029-0080. The information is being collected to meet the requirements of...
New Topical Treatment Options for Actinic Keratosis: A Systematic Review.
Stockfleth, Eggert; Sibbring, Gillian C; Alarcon, Ivette
2016-01-01
This systematic review compared the relative efficacy of 5-fluorouracil 0.5% in salicylic acid 10% (5-FU/SA), ingenol mebutate (IMB) and imiquimod 2.5%/3.75% (IMI) for actinic keratosis on the face, forehead or scalp. Only 11 publications, relating to 7 randomised controlled trials, met inclusion criteria and it was only possible to compare the effect of all 3 treatments on complete clinical clearance, and the effect of 5-FU/SA and IMB on actinic keratosis recurrence rate. Despite a higher vehicle response rate for 5-FU/SA, complete clinical clearance was higher than IMB and IMI (55.4, 42.2, and 25.0-30.6/34.0-35.6%, [corrected] respectively). 5-FU/SA was also associated with lower actinic keratosis recurrence rate than IMB at 12 months post-treatment (32.7 vs. 53.9%). Although qualitative assessment suggested a numerical advantage of 5-FU/SA over IMB and IMI in terms of complete clinical clearance and sustained clearance, clinical data from longer term trials, with comparable outcome measures, are required to corroborate these findings.
Uptake of Tl-201 in the testes: Implications for radiation dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stabin, M.G.; Thomas, S.R.; Wilson, R.A.
The radiation dose to the testes from Tl-201 chloride has been an outstanding question for a number of years. Previous studies have presented kinetic data for the testes with percentage uptake ranging over nearly an order of magnitude from 0.15% to 1.2%. Gupta et al. studied the uptake of Tl-201 in testes and reported an uptake of 0.9-1.2%, with no clearance to 24 hours. Use of the value reported by Gupta et al. results in an estimated dose to the testes in the adult of 0.82 mGy/MBq, and causes the testes to be identified as the highest dose organ. Inmore » our crossover study we evaluated Tl-201 uptake in the testes of 28 patients who received Tl-201 chloride plus D-Ribose, an experimental clearance agent, and Tl-201 chloride plus a placebo 7 to 14 days later. Quantitative measurements were made under a scintillation camera imaging protocol (following exercise and administration of D-Ribose or the placebo) at approximately 1.5, 4.5, 8, 24, and 48 hr, and 7 to 14 days post injection, during which the isolated testes were shielded from the body background. Images were acquired for 5 minutes at early times and 10 to 15 minutes at the latest time. The data were fit to a two component exponential curve. Uptake and clearance parameters were not significantly different between the two regimens. Mean uptake was 0.31 {plus_minus} 0.11%; the mean residence time in the testes was 0.26 {plus_minus}0.08 hr. The testes dose using this new residence time is about 0.20 mGy/MBq. This estimate should form the basis for testicular radiation dosimetry of Tl-201 chloride.« less
NASA Technical Reports Server (NTRS)
Rothrock, A M; Marsh, E T
1935-01-01
Test data and analysis show that the rate of fuel leakage between a lapped plunger and sleeve varies directly with the density of the fuel, the diameter of the plunger, the pressure producing the leakage, and the cube of the mean clearance between the plunger and sleeve. The rate varies inversely as the length of the lapped fit and the viscosity of the fuel. With a mean clearance between the plunger and sleeve of 0.0001 inch the leakage amounts to approximately 0.2 percent of the fuel injected with gasoline and as low as 0.01 percent with diesel fuel oils. With this mean clearance an effective seal is obtained when the length of the lap is three times the diameter of the lap. The deformation of the sleeve and plunger under pressure is sufficient to change the rate of leakage appreciably from that which would be obtained if the clearance was constant under pressure.
Sabnis, Ravindra B; Ganesamoni, Raguram; Doshi, Amit; Ganpule, Arvind P; Jagtap, Jitendra; Desai, Mahesh R
2013-08-01
To compare micropercutaneous nephrolithotomy (microperc) and retrograde intrarenal surgery (RIRS) for the management of renal calculi <1.5 cm with regard to stone clearance rates and surgical characteristics, complications and postoperative recovery. Seventy patients presenting with renal calculi <1.5 cm were equally randomized to a microperc or a RIRS group between February 2011 and August 2012 in this randomized controlled trial. Randomization was based on centralized computer-generated numbers. Patients and authors assessing the outcomes were not blinded to the procedure. Microperc was performed using a 4.85-F (16-gauge) needle with a 272-μm laser fibre. RIRS was performed using a uretero-renoscope. Variables studied were stone clearance rates, operating time, need for JJ stenting, intra-operative and postoperative complications (according to the Clavien-Dindo classification system), surgeon discomfort score, postoperative pain score, analgesic requirement and hospital stay. Stone clearance was assessed using ultrasonography and X-ray plain abdominal film of kidney, ureter and bladder at 3 months. There were 35 patients in each group. All the patients were included in the final analysis. The stone clearance rates in the microperc and RIRS groups were similar (97.1 vs 94.1%, P = 1.0). The mean [sd] operating time was similar between the groups (51.6 [18.5] vs 47.1 [17.5], P = 0.295). JJ stenting was required in a lower proportion of patients in the microperc group (20 vs 62.8%, P < 0.001). Intra-operative complications were a minor pelvic perforation in one patient and transient haematuria in two patients, all in the microperc group. One patient in each group required conversion to miniperc. One patient in the microperc group needed RIRS for small residual calculi 1 day after surgery. The decrease in haemoglobin was greater in the microperc group (0.96 vs 0.56 g/dL, P < 0.001). The incidence of postoperative fever (Clavien I) was similar in the two groups (8.6 vs 11.4%, P = 1.0). None of the patients in the study required blood transfusion. The mean [sd] postoperative pain score at 24 h was slightly higher in the microperc group (1.9 [1.2] vs 1.6 [0.8], P = 0.045). The mean [sd] analgesic requirement was higher in the microperc group (90 [72] vs 40 [41] mg tramadol, P < 0.001). The mean [sd] hospital stay was similar in the two groups (57 [22] vs 48 [18] h, P = 0.08). Microperc is a safe and effective alternative to RIRS for the management of small renal calculi and has similar stone clearance and complication rates when compared to RIRS. Microperc is associated with higher haemoglobin loss, increased pain and higher analgesic requirements, while RIRS is associated with a higher requirement for JJ stenting. © 2013 BJU International.
Toole, Allison R; Ithurburn, Matthew P; Rauh, Mitchell J; Hewett, Timothy E; Paterno, Mark V; Schmitt, Laura C
2017-11-01
Study Design Prospective cohort study. Background While meeting objective criterion cutoffs is recommended prior to return to sports following anterior cruciate ligament (ACL) reconstruction, the number of young athletes who meet recommended cutoffs and the impact of cutoffs on longitudinal sports participation are unknown. Objectives To test the hypothesis that a higher proportion of young athletes who meet recommended cutoffs will maintain the same level of sports participation over the year following return-to-sport clearance compared to those who do not meet recommended cutoffs. Methods At the time of return-to-sport clearance, the International Knee Documentation Committee Subjective Knee Evaluation Form (IKDC), quadriceps and hamstring strength limb symmetry index (LSI), and single-leg hop test LSI were assessed. Proportions of participants who met individual (IKDC score of 90 or greater; strength and hop test LSIs of 90% or greater) and combined cutoffs were calculated. Proportions of participants who continued at the same level of sports participation over the year following return-to-sport clearance (assessed using the Tegner activity scale) were compared between those who met and did not meet cutoffs. Results Participants included 115 young athletes (88 female). The proportions meeting individual cutoffs ranged from 43.5% to 78.3%. The proportions meeting cutoffs for all hop tests, all strength tests, and all combined measures were 53.0%, 27.8%, and 13.9%, respectively. A higher proportion of participants who met cutoffs for both strength tests maintained the same level of sports participation over the year following return-to-sport clearance than those who did not (81.3% versus 60.2%, P = .02). Conclusion The proportions of young athletes after ACL reconstruction recently cleared for return to sports who met the combined criterion cutoffs were low. Those who met the criterion cutoffs for both strength tests maintained the same level of sports participation at higher proportions than those who did not. Level of Evidence Prognosis, level 2b. J Orthop Sports Phys Ther 2017;47(11):825-833. Epub 7 Oct 2017. doi:10.2519/jospt.2017.7227.
Application of the Booth-Kautzmann method for the determination of N-2 packing leakage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burkhart, D.M.; Milton, J.W.; Fawcett, S.T.
1995-06-01
To accurately determine turbine cycle heat rate, leakage past the N-2 steam seal packing must be determined on turbines with both HP and IP turbines contained within a common high pressure casing. N-2 packing leakage can be determined by the Booth-Kautzmann Method with instrumentation commonly used to determine the HP and IP turbine efficiency. The only additional requirements are changes to the main steam and/or hot reheat steam conditions. This paper discusses the actual test results using the Booth-Kautzmann test procedure on three natural gas fired units. The test results demonstrate the added advantage of having at least three N-2more » test runs, stability requirements for repeatable test runs and test procedures used to determine leakage results. Discussion of the sensitivity of the assumed N-2 enthalpy are also addressed. Utilizing Martins Formula with a series of N-2 Leakage test runs is shown to be a leakage prediction tool and a packing clearance approximation tool. It is concluded that the Booth-Kautzmann Method for determination of N-2 packing leakage should be utilized whenever HP and Ip turbine efficiency is determined. The two or three additional hours invested in the test runs is well worth the information gained on the performance of the N-2 packing.« less
Benefits of Using Pairwise Trajectory Management in the Central East Pacific
NASA Technical Reports Server (NTRS)
Chartrand, Ryan; Ballard, Kathryn
2016-01-01
Pairwise Trajectory Management (PTM) is a concept that utilizes airborne and ground-based capabilities to enable airborne spacing operations in oceanic regions. The goal of PTM is to use enhanced surveillance, along with airborne tools, to manage the spacing between aircraft. Due to the enhanced airborne surveillance of Automatic Dependent Surveillance-Broadcast (ADS-B) information and reduced communication, the PTM minimum spacing distance will be less than distances currently required of an air traffic controller. Reduced minimum distance will increase the capacity of aircraft operations at a given altitude or volume of airspace, thereby increasing time on desired trajectory and overall flight efficiency. PTM is designed to allow a flight crew to resolve a specific traffic conflict (or conflicts), identified by the air traffic controller, while maintaining the flight crew's desired altitude. The air traffic controller issues a PTM clearance to a flight crew authorized to conduct PTM operations in order to resolve a conflict for the pair (or pairs) of aircraft (i.e., the PTM aircraft and a designated target aircraft). This clearance requires the flight crew of the PTM aircraft to use their ADS-B-enabled onboard equipment to manage their spacing relative to the designated target aircraft to ensure spacing distances that are no closer than the PTM minimum distance. When the air traffic controller determines that PTM is no longer required, the controller issues a clearance to cancel the PTM operation.
Safety and efficacy of percutaneous nephrolithotomy for the treatment of paediatric urolithiasis
Veeratterapillay, R; Shaw, MBK; Williams, R; Haslam, P; Lall, A; De la Hunt, M; Hasan, ST; Thomas, DJ
2012-01-01
INTRODUCTION Paediatric percutaneous nephrolithotomy (PCNL) has revolutionised the treatment of paediatric nephrolithiasis. Paediatric PCNL has been performed using both adult and paediatric instruments. Stone clearance rates and complications vary according to the technique used and surgeon experience. We present our experience with PCNL using adult instruments and a 28Fr access tract for large renal calculi in children under 18 years. METHODS All patients undergoing PCNL at our institution between 2000 and 2009 were reviewed. Demographics, surgical details and post-operative follow-up information were obtained to identify stone clearance rates and complications. RESULTS PCNL was performed in 32 renal units in 31 patients (mean age: 10.8 years). The mean stone diameter was 19mm (range: 5–40mm). Twenty-six cases required single puncture and six required multiple tracts. Overall, 11 staghorn stones, 10 multiple calyceal stones and 11 single stones were treated. Twenty-seven patients (84%) were completely stone free following initial PCNL. Two cases had extracorporeal shock wave lithotripsy for residual fragments, giving an overall stone free rate of 91% following treatment. There was no significant bleeding or sepsis encountered either during the operation or in the post-operative setting. No patient required or received a blood transfusion. CONCLUSIONS Paediatric PCNL can be performed safely with minimal morbidity using adult instruments for large stone burden, enabling rapid and complete stone clearance. PMID:23131231
Safety and efficacy of percutaneous nephrolithotomy for the treatment of paediatric urolithiasis.
Veeratterapillay, R; Shaw, M B K; Williams, R; Haslam, P; Lall, A; De la Hunt, M; Hasan, S T; Thomas, D J
2012-11-01
Paediatric percutaneous nephrolithotomy (PCNL) has revolutionised the treatment of paediatric nephrolithiasis. Paediatric PCNL has been performed using both adult and paediatric instruments. Stone clearance rates and complications vary according to the technique used and surgeon experience. We present our experience with PCNL using adult instruments and a 28Fr access tract for large renal calculi in children under 18 years. All patients undergoing PCNL at our institution between 2000 and 2009 were reviewed. Demographics, surgical details and post-operative follow-up information were obtained to identify stone clearance rates and complications. PCNL was performed in 32 renal units in 31 patients (mean age: 10.8 years). The mean stone diameter was 19mm (range: 5-40mm). Twenty-six cases required single puncture and six required multiple tracts. Overall, 11 staghorn stones, 10 multiple calyceal stones and 11 single stones were treated. Twenty-seven patients (84%) were completely stone free following initial PCNL. Two cases had extracorporeal shock wave lithotripsy for residual fragments, giving an overall stone free rate of 91% following treatment. There was no significant bleeding or sepsis encountered either during the operation or in the post-operative setting. No patient required or received a blood transfusion. Paediatric PCNL can be performed safely with minimal morbidity using adult instruments for large stone burden, enabling rapid and complete stone clearance.
76 FR 67457 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-01
... clearance request seeks approval to pre- test: (1) Data collection from hospital ambulatory departments... will test the data collection procedures involved in integrating the NHAMCS into the NHCS. NHAMCS has...
77 FR 28597 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-15
... population of the United States. This one-year clearance request seeks approval to pre- test: (1) Data..., expiration date 12/31/2014) data collection. The proposed pretest will test the data collection procedures...
32 CFR 644.26 - Required clearances.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Director of Engineering and Services (AF/PRE) and the Director of Planning, Programming and Analysis (AF/RDXI), as to industrial installations, of Headquarters, USAF, are responsible for initiating all...
32 CFR 644.26 - Required clearances.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Director of Engineering and Services (AF/PRE) and the Director of Planning, Programming and Analysis (AF/RDXI), as to industrial installations, of Headquarters, USAF, are responsible for initiating all...
32 CFR 644.26 - Required clearances.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Director of Engineering and Services (AF/PRE) and the Director of Planning, Programming and Analysis (AF/RDXI), as to industrial installations, of Headquarters, USAF, are responsible for initiating all...
32 CFR 644.26 - Required clearances.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Director of Engineering and Services (AF/PRE) and the Director of Planning, Programming and Analysis (AF/RDXI), as to industrial installations, of Headquarters, USAF, are responsible for initiating all...
32 CFR 644.26 - Required clearances.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Director of Engineering and Services (AF/PRE) and the Director of Planning, Programming and Analysis (AF/RDXI), as to industrial installations, of Headquarters, USAF, are responsible for initiating all...
32 CFR 154.77 - Reporting requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Secret, Secret, and Confidential clearances revoked; (4) Number of SCI access determinations issued; (5) Number of SCI access determinations denied; (6) Number of SCI access determinations revoked; and (7...
Experimental study of uncentralized squeeze film dampers
NASA Technical Reports Server (NTRS)
Quinn, R. D.
1983-01-01
The vibration response of a rotor system supported by a squeeze film damper (SFD) was experimentally investigated in order to provide experimental data in support of the Rotor/Stator Interactive Finite Element theoretical development. Part of the investigation required the designing and building of a rotor/SFD system that could operate with or without end seals in order to accommodate different SFD lengths. SFD variables investigated included clearance, eccentricity mass, fluid pressure, and viscosity and temperature. The results show inlet pressure, viscosity and clearance have significant influence on the damper performance and accompanying rotor response.
Low noise lead screw positioner
NASA Technical Reports Server (NTRS)
Perkins, Gerald S. (Inventor)
1986-01-01
A very precise and low noise lead screw positioner, for positioning a retroreflector in an interferometer is described. A gas source supplies inert pressurized gas, that flows through narrow holes into the clearance space between a nut and the lead screw. The pressurized gas keeps the nut out of contact with the screw. The gas flows axially along the clearance space, into the environment. The small amount of inert gas flowing into the environment minimizes pollution. By allowing such flow into the environment, no seals are required between the end of the nut and the screw.
Thyrotoxic atrial fibrillation.
Parmar, Malvinder S
2005-01-04
Atrial fibrillation is the most common cardiac complication of hyperthyroidism and occurs in 15% of patients with hyperthyroidism. It is associated with a higher risk of thromboembolism that often involves the central nervous system. Oral anticoagulation is important in the majority of these patients to prevent thromboembolic complications. These patients require adjustment in the dose of various rate-controlling agents because of increased clearance associated with hyperthyroidism and a decrease in warfarin dosage because of increased clearance of vitamin K-dependent clotting factors. The management of thyrotoxic atrial fibrillation is summarized in this clinical review.
49 CFR Appendix D to Part 178 - Thermal Resistance Test
Code of Federal Regulations, 2013 CFR
2013-10-01
... large enough in size to fully house the test outer package without clearance problems. The test oven....3Instrumentation. A calibrated recording device or a computerized data acquisition system with an appropriate range... Configuration. Each outer package material type and design must be tested, including any features such as...
49 CFR Appendix D to Part 178 - Thermal Resistance Test
Code of Federal Regulations, 2014 CFR
2014-10-01
... large enough in size to fully house the test outer package without clearance problems. The test oven....3Instrumentation. A calibrated recording device or a computerized data acquisition system with an appropriate range... Configuration. Each outer package material type and design must be tested, including any features such as...
49 CFR Appendix D to Part 178 - Thermal Resistance Test
Code of Federal Regulations, 2011 CFR
2011-10-01
... large enough in size to fully house the test outer package without clearance problems. The test oven....3Instrumentation. A calibrated recording device or a computerized data acquisition system with an appropriate range... Configuration. Each outer package material type and design must be tested, including any features such as...
49 CFR Appendix D to Part 178 - Thermal Resistance Test
Code of Federal Regulations, 2012 CFR
2012-10-01
... large enough in size to fully house the test outer package without clearance problems. The test oven....3Instrumentation. A calibrated recording device or a computerized data acquisition system with an appropriate range... Configuration. Each outer package material type and design must be tested, including any features such as...
NASA Technical Reports Server (NTRS)
Williams, David H.; Green, Steven M.
1993-01-01
Historically, development of airborne flight management systems (FMS) and ground-based air traffic control (ATC) systems has tended to focus on different objectives with little consideration for operational integration. A joint program, between NASA's Ames Research Center (Ames) and Langley Research Center (Langley), is underway to investigate the issues of, and develop systems for, the integration of ATC and airborne automation systems. A simulation study was conducted to evaluate a profile negotiation process (PNP) between the Center/TRACON Automation System (CTAS) and an aircraft equipped with a four-dimensional flight management system (4D FMS). Prototype procedures were developed to support the functional implementation of this process. The PNP was designed to provide an arrival trajectory solution which satisfies the separation requirements of ATC while remaining as close as possible to the aircraft's preferred trajectory. Results from the experiment indicate the potential for successful incorporation of aircraft-preferred arrival trajectories in the CTAS automation environment. Fuel savings on the order of 2 percent to 8 percent, compared to fuel required for the baseline CTAS arrival speed strategy, were achieved in the test scenarios. The data link procedures and clearances developed for this experiment, while providing the necessary functionality, were found to be operationally unacceptable to the pilots. In particular, additional pilot control and understanding of the proposed aircraft-preferred trajectory, and a simplified clearance procedure were cited as necessary for operational implementation of the concept.
NASA Astrophysics Data System (ADS)
Bindon, J.; Alder, D.; Ianovici, I.
1987-11-01
The field of flow visualization has been reviewed and its application to the study of the flow near the tip of an unshrouded axial turbine rotor discussed in detail. The logical conceptualization of experiments which could lead to a final understanding of the flow structure was developed and how this leads to test turbine design philosophy is suggested. The rotor periodicity shed by the stator requires that particle of pulse tracing is needed rather than the more universal continuous streamline trace which arises from a continuous tracer injection at a point in a flow. While the whole field of flow visualization at a rotor tip is demanding because of its very nature, pulse tracking will place a greater demand on the development of new skills and techniques. Since streamline tracking is somewhat more standard, these demands will not be as great. A fundamental choice does however need to be made between the two methods. The suggested experimental turbine should thus, always with the facility of infinitely variable Mach number, model the following: (1) Stationary annular cascade with tip clearance inside a stationary outer endwall; (2) Stationary annular cascade with tip clearance inside a moving endwall; (3) The transfer of flow visualization techniques developed into the rotating frame; (4) Fully rotating rotor with no inlet periodicity; (5) Fully rotating rotor with inlet periodicity.
Li, Yan; Wang, Xiaomin; O'Mara, Edward; Dimopoulos, Meletios A; Sonneveld, Pieter; Weisel, Katja C; Matous, Jeffrey; Siegel, David S; Shah, Jatin J; Kueenburg, Elisabeth; Sternas, Lars; Cavanaugh, Chloe; Zaki, Mohamed; Palmisano, Maria; Zhou, Simon
2017-01-01
Pomalidomide is an immunomodulatory drug for treatment of relapsed or refractory multiple myeloma (rrMM) in patients who often have comorbid renal conditions. To assess the impact of renal impairment on pomalidomide exposure, a population pharmacokinetics (PPK) model of pomalidomide in rrMM patients with various degrees of impaired renal function was developed. Intensive and sparse pomalidomide concentration data collected from two clinical studies in rrMM patients with normal renal function, moderately impaired renal function, severely impaired renal function not requiring dialysis, and with severely impaired renal function requiring dialysis were pooled over the dose range of 2 to 4 mg, to assess specifically the influence of the impaired renal function as a categorical variable and a continuous variable on pomalidomide clearance and plasma exposure. In addition, pomalidomide concentration data collected on dialysis days from both the withdrawal (arterial) side and from the returning (venous) side of the dialyzer, from rrMM patients with severely impaired renal function requiring dialysis, were used to assess the extent to which dialysis contributes to the removal of pomalidomide from blood circulation. PPK analyses demonstrated that moderate to severe renal impairment not requiring dialysis has no influence on pomalidomide clearance or plasma exposure, as compared to those patients with normal renal function, while pomalidomide exposure increased approximately 35% in patients with severe renal impairment requiring dialysis on nondialysis days. In addition, dialysis increased total body pomalidomide clearance from 5 L/h to 12 L/h, indicating that dialysis will significantly remove pomalidomide from the blood circulation. Thus, pomalidomide should be administered post-dialysis on the days of dialysis.
Shah, Dimpy P; Grimes, Carolyn Z; Brown, Eric; Hwang, Lu-Yu
2012-02-01
Hepatitis C virus (HCV), an emerging bloodborne pathogen, causes chronic liver disease frequently except in about 10-20% of infections which undergo spontaneous resolution. Investigating factors that influence viral clearance is essential to understand the natural history of this infection and establishing novel strategies for prevention and treatment. HCV clearance was estimated in a unique cohort of 1,260 HIV and HBV negative current drug users enrolled for a hepatitis B vaccination study. It was defined as the inability to detect viral RNA using a PCR method in presence of serum anti-HCV antibody EIA. Associated demographic and socio-behavioral factors including drug use patterns were identified from the enrolled subjects using multivariate regression analysis. 33.3% (420/1260) of drug users were found positive for anti-HCV antibodies and 14.8% (62/420) of these individuals achieved viral clearance (negative PCR test). Race or ethnicity of the participants was the only significant factor associated with HCV clearance. Hispanics (OR = 3.4, 95% CI: 1.3-8.5, P = 0.01) and Caucasians (OR = 3.1, 95% CI: 1.5-6.6, P = 0.003) had significantly higher odds of clearing the virus compared to African Americans when adjusted for age and gender. None of the socio-behavioral factors including alcohol intake and drug use patterns were significant determinants of HCV clearance. Racial or ethnic differences in HCV clearance were observed in this study suggesting an important role of host genetic susceptibility factors in determining the clinical course of this disease. Further research is needed to examine these genetic associations of host-virus relationships. Copyright © 2011 Wiley Periodicals, Inc.
30 CFR 764.10 - Information collection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Information collection. 764.10 Section 764.10... § 764.10 Information collection. The information collection requirements contained in §§ 764.21 and 764... clearance number 1029-0030. The information required in § 764.21 is necessary to allow the regulatory...
30 CFR 764.10 - Information collection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Information collection. 764.10 Section 764.10... § 764.10 Information collection. The information collection requirements contained in §§ 764.21 and 764... clearance number 1029-0030. The information required in § 764.21 is necessary to allow the regulatory...
19 CFR 4.70 - Public Health Service requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Public Health Service requirements. 4.70 Section 4... THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Foreign Clearances § 4.70 Public Health Service... Public Health Service. [T.D. 00-4, 65 FR 2874, Jan. 19, 2000] ...
19 CFR 4.70 - Public Health Service requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 1 2011-04-01 2011-04-01 false Public Health Service requirements. 4.70 Section 4... THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Foreign Clearances § 4.70 Public Health Service... Public Health Service. [T.D. 00-4, 65 FR 2874, Jan. 19, 2000] ...
19 CFR 4.70 - Public Health Service requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 1 2012-04-01 2012-04-01 false Public Health Service requirements. 4.70 Section 4... THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Foreign Clearances § 4.70 Public Health Service... Public Health Service. [T.D. 00-4, 65 FR 2874, Jan. 19, 2000] ...
19 CFR 4.70 - Public Health Service requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 1 2013-04-01 2013-04-01 false Public Health Service requirements. 4.70 Section 4... THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Foreign Clearances § 4.70 Public Health Service... Public Health Service. [T.D. 00-4, 65 FR 2874, Jan. 19, 2000] ...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-08
... information collection burden. We are, however, requesting an emergency review of the information collection... for emergency review. We are requesting an emergency review to ensure compliance with section 1862(a... Information Collection: Medicare Fee-for-Service Prepayment Medical Review; Use: The information required...
19 CFR 4.70 - Public Health Service requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 1 2014-04-01 2014-04-01 false Public Health Service requirements. 4.70 Section 4... THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Foreign Clearances § 4.70 Public Health Service... Public Health Service. [T.D. 00-4, 65 FR 2874, Jan. 19, 2000] ...
78 FR 9666 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-11
...: Desk Officer for Agriculture, Office of Information and Regulatory Affairs, Office of Management and... Information: The objective of the NAHRS is to collect data needed to report the presence of confirmed clinical... information collection requirement(s) to OMB for review and clearance under the Paperwork Reduction Act of...
78 FR 52496 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-23
... DEPARTMENT OF AGRICULTURE Submission for OMB Review; Comment Request August 19, 2013. The Department of Agriculture has submitted the following information collection requirement(s) to OMB for review and clearance under the Paperwork Reduction Act of 1995, Public Law 104-13. Comments regarding (a) Whether the collection of information is...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-19
... of 1995, FAA invites public comments about our intention to request the Office of Management and... whether required maintenance actions have been accomplished on light-sport aircraft. The information is... aircraft. The information is used by FAA safety inspectors in determining whether required maintenance...
75 FR 17410 - Federal Acquisition Regulation; Information Collection; Government Property
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-06
... contractors to submit inventory disposal schedules to the Plant Clearance Officer. (l) FAR 52.245-9(d... of appropriate technological collection techniques or other forms of information technology. DATES... following requirements: (a) FAR 45.606-1 requires a contractor to submit inventory schedules. (b) FAR 45.606...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-24
... of Inventory Schedules; DD Form 1639, Scrap Warranty; DD Form 1640, Request for Plant Clearance; DD... respondents, including the use of automated collection techniques or other forms of information technology... contractor inventory. a. DFARS 211.274, Item identification and valuation requirements, and the associated...
7 CFR 1724.52 - Permitted deviations from RUS construction standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...
7 CFR 1724.52 - Permitted deviations from RUS construction standards.
Code of Federal Regulations, 2013 CFR
2013-01-01
.... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...
7 CFR 1724.52 - Permitted deviations from RUS construction standards.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...
7 CFR 1724.52 - Permitted deviations from RUS construction standards.
Code of Federal Regulations, 2012 CFR
2012-01-01
.... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...
7 CFR 1724.52 - Permitted deviations from RUS construction standards.
Code of Federal Regulations, 2014 CFR
2014-01-01
.... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...
75 FR 43526 - Agency Information Collection Activities; Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-26
... information collection requirements described below will be submitted to the Office of Management and Budget... collection requirements contained in its Affiliate Marketing Rule (or ``Rule''). That clearance expires on...MarketingPRA ) (and following the instructions on the web-based form). Comments filed in paper form should...
75 FR 41860 - Agency Information Collection Activities;Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-19
... information collection requirements described below will be submitted to the Office of Management and Budget... collection requirements contained in its Affiliate Marketing Rule (or ``Rule''). That clearance expires on...MarketingPRA ) (and following the instructions on the web-based form). Comments filed in paper form should...
2 CFR 215.51 - Monitoring and reporting program performance.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., such quantitative data should be related to cost data for computation of unit costs. (2) Reasons why..., analysis and explanation of cost overruns or high unit costs. (e) Recipients shall not be required to... clearance requirements of 5 CFR part 1320 when requesting performance data from recipients. ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-03
... Dependent Surveillance--Broadcast (ADS-B) Out Performance Requirements to Support Air Traffic Control (ATC... Dependent Surveillance--Broadcast (ADS-B) Equipage Mandate To Support Air Traffic Control Service'' (75 FR... Surveillance--Broadcast (ADS-B) Out Performance Requirements to Support Air Traffic Control (ATC) Service Form...
77 FR 64462 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
... information collection requirement(s) to OMB for review and clearance under the Paperwork Reduction Act of 1995, Public Law 104-13. Comments regarding (a) whether the collection of information is necessary for the proper performance of the functions of the agency, including whether the information will have...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-22
... Aviation Maintenance Technician Schools meet the minimum requirements for procedures and curriculum set forth by the FAA in FAR Part 147. Applicants submit FAA Form 8310-6, Aviation Maintenance Technician... FAR Part 147 requirements have been met, an aviation maintenance technician school certificate with...
75 FR 1584 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-12
... DEPARTMENT OF AGRICULTURE Submission for OMB Review; Comment Request January 7, 2010. The Department of Agriculture has submitted the following information collection requirement(s) to OMB for review and clearance under the Paperwork Reduction Act of 1995, Public Law 104-13. Comments regarding (a) whether the collection of information is...
SSME seal test program: Test results for hole-pattern damper seals
NASA Technical Reports Server (NTRS)
Childs, D. W.
1985-01-01
The results consisting of direct and transverse force coefficients are presented for thirteen, hole-pattern, damper-seal configurations. The designation damper seal refers to a seal which uses a deliberately roughened stator nd smooth rotor, to increase the net damping force developed by a seal. The designation hole-pattern refers to a stator roughness pattern which is developed by a pattern of round holes while are milled into the stator. All seals tested use the same smooth rotor and have the same constant minimum clearance. The seal tests examined the following major design options: (1) hole-area density, i.e., the proportion of stator surface area consumed by holes; and (2) hole depth, particularly the ratio of hole depth to minimum clearance. In addition, limited data were taken to examine the influence of in-line versus staggered hole patterns and flat-bottomed versus spherical-bottomed holes.
Bruno, René; Baille, Pascale; Retout, Sylvie; Vivier, Nicole; Veyrat-Follet, Christine; Sanderink, Ger-Jan; Becker, Richard; Antman, Elliott M
2003-01-01
Aims A major concern with any antithrombotic therapy is an increase in the risk of haemorrhage. The aim of this study was to analyse population pharmacokinetics and pharmacokinetic/pharmacodynamic (PK/PD) relationships for enoxaparin in patients with unstable angina (UA) and non-ST-segment elevation myocardial infarction (NSTEMI), which may help predict risk of haemorrhage. Methods Anti-factor Xa (anti-Xa) activity was measured as marker of enoxaparin concentration in 448 patients receiving the drug as a single 30-mg intravenous bolus followed by 1.0 or 1.25 mg kg−1 subcutaneously twice a day. A population pharmacokinetic analysis was conducted and individual estimates of enoxaparin clearance and area under the curve were tested as prognostic factors for the occurrence of haemorrhagic episodes. Results Basic population PK parameters were an enoxaparin clearance of 0.733 l h−1[95% confidence interval (CI) 0.698, 0.738], a distribution volume of 5.24 l (95% CI 4.20, 6.28) and an elimination half-life of 5.0 h. Enoxaparin clearance was significantly related to patient weight and creatinine clearance, and was the only independent predictor of experiencing both all (10.7%, P = 0.0013) and major (2.2%, P = 0.0004) haemorrhagic events. A creatinine clearance of 30 ml min−1 was associated with a decrease in enoxaparin clearance of 27% compared with that in a patient with a median creatinine clearance of 88 ml min−1, and was related to a 1.5- and 3.8-fold increase in the risk of ‘all’ and ‘major’ haemorrhagic episodes, respectively. Conclusions Enoxaparin clearance depends on body weight, and, therefore, weight-adjusted dosing is recommended to minimize interpatient variability in drug exposure and the risk of haemorrhage. The importance of an increased risk of haemorrhage with decreasing renal function must be weighed against the benefit of treatment with enoxaparin in patients with UA and NSTEMI. PMID:12968985
Effects of nitrogen dioxide on respiratory tract clearance in the ferret
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rasmussen, R.E.; Mannix, R.C.; Oldham, M.J.
1994-01-01
During growth and development, young children are periodically exposed to relatively high concentrations of various air contaminants, including tobacco smoke and environmental pollutants generated by fossil fuel use. The effects of these exposures on respiratory function and lung development are difficult to determine because of interindividual variation and lack of accurate dosimetry. To provide information on the effects of chronic exposure to a common indoor and outdoor pollutant during lung development, a study was performed to assess the effects of exposure to two concentrations of nitrogen dioxide (NO[sub 2]; 0.5 or 10 ppm) on tracer particle clearance from the airwaysmore » of ferrets exposed during postnatal respiratory tract development. Separate groups of ferrets were exposed nose-only to the test atmospheres or clean air 4 h/d, 5 d/wk, for either 8 or 15 wk. Those animals exposed for 8 wk were subsequently housed in a filtered air environment until the particle clearance measurements commenced at 3 wk prior to the end of the 15-wk exposure protocol. Radiolabeled ([sup 51]Cr) tracer particles were deposited in the respiratory tract of all animals by inhalation, and the clearance rates from the head and thoracic regions were separately monitored for 18 d. No significant effects of the NO[sub 2] exposure on head airways clearance were seen. In contrast, the rates of particle clearance from the thorax of both the 8- and 15-wk groups exposed to 10 ppm NO[sub 2] were significantly reduced, and did not differ from each other. Thoracic clearance was also reduced in animals exposed to 0.5 ppm, but the rate was not significantly different from that of the clean air exposed controls. These results show that NO[sub 2] at moderate concentrations caused highly significant changes in the deep lung of the juvenile ferret, and suggest that impairment of the clearance function may be only slowly recovered after chronic exposure. 35 refs., 1 fig., 1 tab.« less
Active control of surge in centrifugal compressors using magnetic thrust bearing actuation
NASA Astrophysics Data System (ADS)
Sanadgol, Dorsa
This research presents a new method for active surge control in centrifugal compressors with unshrouded impellers using a magnetic thrust bearing to modulate the impeller tip clearance. Magnetic bearings offer the potential for active control of flow instabilities. This capability is highly dependent on the sensitivity of the compressor characteristics to blade tip clearance. If the position of the shaft can be actuated with sufficient authority and speed, the induced pressure modulation makes control of surge promising. The active nature of the magnetic bearing system makes the real-time static and dynamic positioning of the rotor and therefore modulation of the impeller tip clearance possible. A theoretical model is first established that describes the sensitivity of the centrifugal compressor characteristic curve to tip clearance variations induced by axial motion of the rotor. Results from simulation of the nonlinear model for a single stage high-speed centrifugal compressor show that using the proposed control method, mass flow and pressure oscillations associated with compressor surge are quickly suppressed with acceptable tip clearance excursions, typically less than 20% of the available clearance. It is shown that it is possible to produce adequate axial excursions in the clearance between the impeller blades and the adjacent stationary shroud using a magnetic thrust bearing with practical levels of drive voltage. This surge control method would allow centrifugal compressors to reliably and safely operate with a wider range than is currently done in the field. The principal advantage of the proposed approach over conventional surge control methods lies in that, in machines already equipped with magnetic bearing, the method can potentially be implemented by simply modifying controller software. This dispenses with the need to introduce additional hardware, permitting adaptation of existing machinery at virtually no cost. In addition, since the controller is designed with the objective of keeping the trajectories on the compressor characteristic curve, the compressor performance and efficiency are no longer sacrificed by excessive recycling to achieve stability. In order to explore these conjectures experimentally, a high speed centrifugal compressor test facility with active magnetic bearings is developed. The test facility can be used for implementing the proposed surge control method and also for assessing the impeller and bearing loads at off-design conditions. This data can then be used to verify and refine analytical models used in compressor design. (Abstract shortened by UMI.)
24 CFR 35.510 - Required procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES HUD-Owned Single Family... and clearance are not completed before the closing of the sale, the Department shall assure that paint...
50 CFR 14.55 - Exceptions to clearance requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF... into the United States; and (c) Certain antique articles as specified in § 14.22 which have been...
50 CFR 14.55 - Exceptions to clearance requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF... into the United States; and (c) Certain antique articles as specified in § 14.22 which have been...
50 CFR 14.55 - Exceptions to clearance requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF... into the United States; and (c) Certain antique articles as specified in § 14.22 which have been...
50 CFR 14.55 - Exceptions to clearance requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF... into the United States; and (c) Certain antique articles as specified in § 14.22 which have been...
50 CFR 14.55 - Exceptions to clearance requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF... into the United States; and (c) Certain antique articles as specified in § 14.22 which have been...
Verse, T; Klöcker, N; Riedel, F; Pirsig, W; Scheithauer, M O
2004-07-01
Recent technical developments in metered pump systems allow the production and use of preservative-free nasal products. The aim of the current study is to compare the tolerability of a preservative-free dexpanthenol (5%) nasal spray with that of the established dexpanthenol (5%) nasal ointment, also without preservatives. The main outcome measure was in vivo mucociliary clearance. Mucociliary clearance was assessed by saccharin migration time in 20 volunteers. Wash-out phases were 7 days and the spray or ointment was always applied 20 min before the saccharin test. The study was designed to test for non-inferiority. Saccharin migration time was slightly longer after ointment administration, however, these were not significantly different to nasal spray. The saccharin migration time showed a significant correlation with the age of the volunteers. The upper confidence limit of dexpanthenol nasal spray was markedly less than that of the ointment. Therefore, dexpanthenol nasal spray is at least equal to if not better than dexpanthenol nasal ointment. Due to its ease of administration, preservative-free dexpanthenol nasal spray offers a valuable therapeutic alternative.
Correlates of diuretic renography in experimental hydronephrosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kekomaeki, M.R.; Rikalainen, H.; Ruotsalainen, P.
1989-02-01
We studied the correlations between diuretic renographs and kidney function in experimental hydronephrosis in rabbits. Features of furosemide-stimulated /sup 99m/Tc-diethylenetriamine-pentaacetic acid renographs were compared to the growth rate, thirst test and endogenous creatinine clearance rate in a chronic solitary-kidney animal model. Intravenous pyelograms, done four weeks after laparotomy, left nephrectomy, bladder resection and constriction of the right pyeloureteric junction, showed signs of obstruction in all the 12 animals of the experimental group. An absent tracer washout after intravenous furosemide, found in five animals, was associated with retarded growth, isosthenuria and an abnormal creatinine clearance. In all of the other sevenmore » animals, a distinct tracer washout after intravenous furosemide was accompanied with a normal growth rate and creatinine clearance. However, no one of these seven animals had a normal ability to retain water and concentrate urine in the thirst test. We conclude that, in this experimental model, a furosemide-induced tracer washout from the kidney pelvis cannot be taken as a proof of the absence of any upper urinary tract obstruction.« less
Progress on Shape Memory Alloy Actuator Development for Active Clearance Control
NASA Technical Reports Server (NTRS)
DeCastro, Jonathan; Melcher, Kevin; Noebe, Ronald
2006-01-01
Results of a numerical analysis evaluating the feasibility of high-temperature shape memory alloys (HTSMA) for active clearance control actuation in the high-pressure turbine section of a modern turbofan engine has been conducted. The prototype actuator concept considered here consists of parallel HTSMA wires attached to the shroud that is located on the exterior of the turbine case. A transient model of an HTSMA actuator was used to evaluate active clearance control at various operating points in a test bed aircraft engine simulation. For the engine under consideration, each actuator must be designed to counteract loads from 380 to 2000 lbf and displace at least 0.033 in. Design results show that an actuator comprised of 10 wires 2 in. in length is adequate for control at critical engine operating points and still exhibit acceptable failsafe operability and cycle life. A proportional-integral-derivative (PID) controller with integrator windup protection was implemented to control clearance amidst engine transients during a normal mission. Simulation results show that the control system exhibits minimal variability in clearance control performance across the operating envelope. The final actuator design is sufficiently small to fit within the limited space outside the high-pressure turbine case and is shown to consume only small amounts of bleed air to adequately regulate temperature.
Daghini, Elena; Juillard, Laurent; Haas, John A; Krier, James D; Romero, Juan C; Lerman, Lilach O
2007-02-01
To prospectively compare in pigs three mathematic models for assessment of glomerular filtration rate (GFR) on electron-beam (EB) computed tomographic (CT) images, with concurrent inulin clearance serving as the reference standard. This study was approved by the institutional animal care and use committee. Inulin clearance was measured in nine pigs (18 kidneys) and compared with single-kidney GFR assessed from renal time-attenuation curves (TACs) obtained with EB CT before and after infusion of the vasodilator acetylcholine. CT-derived GFR was calculated with the original and modified Patlak methods and with previously validated extended gamma variate modeling of first-pass cortical TACs. Statistical analysis was performed to assess correlation between CT methods and inulin clearance for estimation of GFR with least-squares regression analysis and Bland-Altman graphical representation. Comparisons within groups were performed with a paired t test. GFR assessed with the original Patlak method indicated poor correlation with inulin clearance, whereas GFR assessed with the modified Patlak method (P < .001, r = 0.75) and with gamma variate modeling (P < .001, r = 0.79) correlated significantly with inulin clearance and indicated an increase in response to acetylcholine. CT-derived estimates of GFR can be significantly improved by modifications in image analysis methods (eg, use of a cortical region of interest). (c) RSNA, 2007.
Continued clearance of apoptotic cells critically depends on the phagocyte Ucp2 protein.
Park, Daeho; Han, Claudia Z; Elliott, Michael R; Kinchen, Jason M; Trampont, Paul C; Das, Soumita; Collins, Sheila; Lysiak, Jeffrey J; Hoehn, Kyle L; Ravichandran, Kodi S
2011-08-21
Rapid and efficient removal of apoptotic cells by phagocytes is important during development, tissue homeostasis and in immune responses. Efficient clearance depends on the capacity of a single phagocyte to ingest multiple apoptotic cells successively, and to process the corpse-derived cellular material. However, the factors that influence continued clearance by phagocytes are not known. Here we show that the mitochondrial membrane potential of the phagocyte critically controls engulfment capacity, with lower potential enhancing engulfment and vice versa. The mitochondrial membrane protein Ucp2, which acts to lower the mitochondrial membrane potential, was upregulated in phagocytes engulfing apoptotic cells. Loss of Ucp2 reduced phagocytic capacity, whereas Ucp2 overexpression enhanced engulfment. Mutational and pharmacological studies indicated a direct role for Ucp2-mediated mitochondrial function in phagocytosis. Macrophages from Ucp2-deficient mice were impaired in phagocytosis in vitro, and Ucp2-deficient mice showed profound in vivo defects in clearing dying cells in the thymus and testes. Collectively, these data indicate that mitochondrial membrane potential and Ucp2 are key molecular determinants of apoptotic cell clearance. As Ucp2 is linked to metabolic diseases and atherosclerosis, this newly discovered role for Ucp2 in apoptotic cell clearance has implications for the complex aetiology and pathogenesis of these diseases.
Roberts, Jessica K; Stockmann, Chris; Ward, Robert M; Beachy, Joanna; Baserga, Mariana C; Spigarelli, Michael G; Sherwin, Catherine M T
2015-12-01
The aim of this study was to determine the population pharmacokinetics of darbepoetin alfa in hypothermic neonates with hypoxic-ischemic encephalopathy treated with hypothermia. Neonates ≥36 weeks gestation and <12 h postpartum with moderate to severe hypoxic-ischemic encephalopathy who were undergoing hypothermia treatment were recruited in this randomized, multicenter, investigational, new drug pharmacokinetic study. Two intravenous darbepoetin alfa treatment groups were evaluated: 2 and 10 µg/kg. Serum erythropoietin concentrations were measured using an enzyme-linked immunosorbent assay. Monolix 4.3.1 was used to estimate darbepoetin alfa clearance and volume of distribution. Covariates tested included: birthweight, gestational age, postnatal age, postmenstrual age, sex, Sarnat score, and study site. Darbepoetin alfa pharmacokinetics were well described by a one-compartment model with exponential error. Clearance and the volume of distribution were scaled by birthweight (centered on the mean) a priori. Additionally, gestational age (also centered on the mean) significantly affected darbepoetin alfa clearance. Clearance and volume of distribution were estimated as 0.0465 L/h (95% confidence interval 0.0392-0.0537) and 1.58 L (95% confidence interval 1.29-1.87), respectively. A one-compartment model successfully described the pharmacokinetics of darbepoetin alfa among hypothermic neonates treated for hypoxic-ischemic encephalopathy. Clearance decreased with increasing gestational age.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-05
... compliance with the requirement of section 3506(c)(2)(A) of the Paperwork Reduction Act of 1995, the Centers... collection referenced below. In compliance with the requirement of section 3506(c)(2)(A) of the Paperwork... with Section 1833(t) of the Social Security Act (42 U.S.C. 1395l(t)(17)). 1. Type of Information...
Effect of steady flight loads on JT9D-7 performance deterioration
NASA Technical Reports Server (NTRS)
Jay, A.; Todd, E. S.
1978-01-01
Short term engine deterioration occurs in less than 250 flights on a new engine and in the first flights following engine repair; while long term deterioration involves primarily hot section distress and compression system losses which occur at a somewhat slower rate. The causes for short-term deterioration are associated with clearance changes which occur in the flight environment. Analytical techniques utilized to examine the effects of flight loads and engine operating conditions on performance deterioration are presented. The role of gyroscopic, gravitational, and aerodynamic loads are discussed along with the effect of variations in engine build clearances. These analytical results are compared to engine test data along with the correlation between analytically predicted and measured clearances and rub patterns. Conclusions are drawn and important issues are discussed.
Hover and Wind-Tunnel Testing of Shrouded Rotors for Improved Micro Air Vehicle Design
2008-01-01
and the shroud surface pressure distributions. The uniformity of the wake was improved by the presence of the shrouds and by decreasing the blade tip...213 3.35 Effect of blade tip clearance on shrouded-rotor exit-plane wake profiles215 3.36 Effects of changing blade tip clearance on induced...Wright [139] developed a vortex wake model for heavily loaded ducted fans, in which the “inner vortex sheets [shed from the blades ] move at a different
Transporters affecting biochemical test results: Creatinine-drug interactions.
Chu, X; Bleasby, K; Chan, G H; Nunes, I; Evers, R
2016-11-01
Creatinine is eliminated by the kidneys through a combination of glomerular filtration and active transport. Drug-induced increases in serum creatinine (SCr) and/or reduced creatinine renal clearance are used as a marker for acute kidney injury. However, inhibition of active transport of creatinine can result in reversible and, therefore, benign increases in SCr levels. Herein, the transporters involved in creatinine clearance are discussed, in addition to limitations of using creatinine as a biomarker for kidney damage. © 2016 American Society for Clinical Pharmacology and Therapeutics.
Boeing 18-Inch Fan Rig Broadband Noise Test
NASA Technical Reports Server (NTRS)
Ganz, Ulrich W.; Joppa, Paul D.; Patten, Timothy J.; Scharpf, Daniel F.
1998-01-01
The purposes of the subject test were to identify and quantify the mechanisms by which fan broadband noise is produced, and to assess the validity of such theoretical models of those mechanisms as may be available. The test was conducted with the Boeing 18-inch fan rig in the Boeing Low-Speed Aeroacoustic Facility (LSAF). The rig was designed to be particularly clean and geometrically simple to facilitate theoretical modeling and to minimize sources of interfering noise. The inlet is cylindrical and is equipped with a boundary layer suction system. The fan is typical of modern high-by-pass ratio designs but is capable of operating with or without fan exit guide vanes (stators), and there is only a single flow stream. Fan loading and tip clearance are adjustable. Instrumentation included measurements of fan performance, the unsteady flow field incident on the fan and stators, and far-field and in-duct acoustic fields. The acoustic results were manipulated to estimate the noise generated by different sources. Significant fan broadband noise was found to come from the rotor self-noise as measured with clean inflow and no boundary layer. The rotor tip clearance affected rotor self-noise somewhat. The interaction of the rotor with inlet boundary layer turbulence is also a significant source, and is strongly affected by rotor tip clearance. High level noise can be generated by a high-order nonuniform rotating at a fraction of the fan speed, at least when tip clearance and loading are both large. Stator-generated noise is the loudest of the significant sources, by a small margin, at least on this rig. Stator noise is significantly affected by propagation through the fan.
Schmidt, David M; Scrivani, Peter V; Dykes, Nathan L; Goldstein, Richard M; Erb, Hollis N; Reeves, Anthony P
2012-04-01
To compare estimation of glomerular filtration rate determined via conventional methods (ie, scintigraphy and plasma clearance of technetium Tc 99m pentetate) and dynamic single-slice computed tomography (CT). 8 healthy adult cats. Scintigraphy, plasma clearance testing, and dynamic CT were performed on each cat on the same day; order of examinations was randomized. Separate observers performed GFR calculations for scintigraphy, plasma clearance testing, or dynamic CT. Methods were compared via Bland-Altman plots and considered interchangeable and acceptable when the 95% limits of agreement (mean difference between methods ± 1.96 SD of the differences) were ≤ 0.7 mL/min/kg. Global GFR differed < 0.7 mL/min/kg in 5 of 8 cats when comparing plasma clearance testing and dynamic CT; the limits of agreement were 1.4 and -1.7 mL/min/kg. The mean ± SD difference was -0.2 ± 0.8 mL/min/kg, and the maximum difference was 1.6 mL/min/kg. The mean ± SD difference (absolute value) for percentage filtration by individual kidneys was 2.4 ± 10.5% when comparing scintigraphy and dynamic CT; the maximum difference was 20%, and the limits of agreement were 18% and 23% (absolute value). GFR estimation via dynamic CT exceeded the definition for acceptable clinical use, compared with results for conventional methods, which was likely attributable to sample size and preventable technical complications. Because 5 of 8 cats had comparable values between methods, further investigation of dynamic CT in a larger sample population with a wide range of GFR values should be performed.
Spada, E; Mele, A; Berton, A; Ruggeri, L; Ferrigno, L; Garbuglia, A R; Perrone, M P; Girelli, G; Del Porto, P; Piccolella, E; Mondelli, M U; Amoroso, P; Cortese, R; Nicosia, A; Vitelli, A; Folgori, A
2004-01-01
Background/Aims: Hepatitis C virus (HCV) infection results in a high frequency of chronic disease. The aim of this study was to identify early prognostic markers of disease resolution by performing a comprehensive analysis of viral and host factors during the natural course of acute HCV infection. Methods: The clinical course of acute hepatitis C was determined in 34 consecutive patients. Epidemiological and virological parameters, as well as cell mediated immunity (CMI) and distribution of human leukocyte antigens (HLA) alleles were analysed. Results: Ten out of 34 patients experienced self-limiting infection, with most resolving patients showing fast kinetics of viral clearance: at least one negative HCV RNA test during this phase predicted a favourable outcome. Among other clinical epidemiological parameters measured, the self-limiting course was significantly associated with higher median peak bilirubin levels at the onset of disease, and with the female sex, but only the latter parameter was independently associated after multivariate analysis. No significant differences between self-limiting or chronic course were observed for the distribution of DRB1 and DQB1 alleles. HCV specific T cell response was more frequently detected during acute HCV infection, than in patients with chronic HCV disease. A significantly broader T cell response was found in patients with self-limiting infection than in those with chronic evolving acute hepatitis C. Conclusion: The results suggest that host related factors, in particular sex and CMI, play a crucial role in the spontaneous clearance of this virus. Most importantly, a negative HCV RNA test and broad CMI within the first month after onset of the symptoms represent very efficacious predictors of viral clearance and could thus be used as criteria in selecting candidates for early antiviral treatment. PMID:15479691