Sample records for clinical computerized tomographic

  1. Nuclear medicine in clinical neurology: an update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldendorf, W.H.

    1981-01-01

    Isotope scanning using technetium 99m pertechnetate has fallen into disuse since the advent of x-ray computerized tomography. Regional brain blood flow studies have been pursued on a research basis. Increased regional blood flow during focal seizure activity has been demonstrated and is of use in localizing such foci. Cisternography as a predictive tool in normal pressure hydrocephalus is falling into disuse. Positron tomographic scanning is a potent research tool that can demonstrate both regional glycolysis and blood flow. Unfortunately, it is extremely expensive and complex to apply in a clinical setting. With support from the National Institutes of Health, sevenmore » extramural centers have been funded to develop positron tomographic capabilities, and they will greatly advance our knowledge of stroke pathophysiology, seizure disorders, brain tumors, and various degenerative diseases. Nuclear magnetic resonance imaging is a potentially valuable tool since it creates tomographic images representing the distribution of brain water. No tissue ionization is produced, and images comparable to second-generation computerized tomographic scans are already being produced in humans.« less

  2. Results of the National CT Colonography Trial: Questions and Answers

    Cancer.gov

    Learn the results of the National Computerized Tomographic Colonography (CTC) clinical trial, which evaluated how well CTC identifies participants with at least one significantly large polyp using colonoscopy as the gold (or reference) standard.

  3. Prospective radiographic followup after en bloc ligation of the renal hilum.

    PubMed

    White, Wesley M; Klein, Frederick A; Gash, Judson; Waters, W Bedford

    2007-11-01

    We determined the risk of arteriovenous fistula after en bloc ligation of the renal hilum. A prospective evaluation of all patients who underwent en bloc ligation of the renal hilum during nephrectomy for malignant disease was performed. Pertinent operative data were recorded and patients were followed for clinical evidence of arteriovenous fistula formation, including hypertension, abdominal bruit and new onset congestive heart failure. Patients with at least 12 months of followup underwent computerized tomographic arteriography to assess arteriovenous fistula formation. A total of 94 patients underwent en bloc renal hilar ligation during open (43) and laparoscopic (51) nephrectomy using a 45 mm titanium endovascular stapler. Of this cohort 11 patients were lost to followup and 3 died of disease. The remaining 80 patients were followed an average of 35.2 months with no clinical evidence of arteriovenous fistula formation. Specifically there was no statistically significant difference in preoperative and postoperative blood pressure (p = 0.18 and 0.62, respectively), no evidence of abdominal bruit on examination and no new onset congestive heart failure. A total of 32 had increased serum creatinine and, therefore, they were excluded from followup computerized tomographic arteriography. Eight patients had a followup of less than 1 year and they were not yet eligible for evaluation. In the 40 patients who underwent computerized tomographic arteriography no fistulas were noted. Based on clinical followup and prospective radiographic evaluation there appears to be a low risk of arteriovenous fistula formation after en bloc ligation of the renal hilum using a titanium endovascular stapler.

  4. 3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration.

    PubMed

    Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh

    2015-04-22

    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.

  5. ECAT: A New Computerized Tomographic Imaging System for Position-Emitting Radiopharmaceuticals

    DOE R&D Accomplishments Database

    Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Kuhl, D. E.

    1977-01-01

    The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems.

  6. Computerized tomographic quantification of chronic obstructive pulmonary disease as the principal determinant of frontal P vector.

    PubMed

    Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David

    2012-04-01

    Verticalization of the P-wave axis is characteristic of chronic obstructive pulmonary disease (COPD). We studied the correlation of P-wave axis and computerized tomographically quantified emphysema in patients with COPD/emphysema. Individual correlation of P-wave axis with different structural types of emphysema was also studied. High-resolution computerized tomographic scans of 23 patients >45 years old with known COPD were reviewed to assess the type and extent of emphysema using computerized tomographic densitometric parameters. Electrocardiograms were then independently reviewed and the P-wave axis was calculated in customary fashion. Degree of the P vector (DOPV) and radiographic percent emphysematous area (RPEA) were compared for statistical correlation. The P vector and RPEA were also directly compared to the forced expiratory volume at 1 second. RPEA and the P vector had a significant positive correlation in all patients (r = +0.77, p <0.0001) but correlation was very strong in patients with predominant lower lobe emphysema (r = +0.89, p <0.001). Forced expiratory volume at 1 second and the P vector had almost a linear inverse correlation in predominantly lower lobe emphysema (r = -0.92, p <0.001). DOPV positively correlated with radiographically quantified emphysema. DOPV and RPEA were strong predictors of qualitative lung function in patients with predominantly lower lobe emphysema. In conclusion, a combination of high DOPV and predominantly lower lobe emphysema indicates severe obstructive lung dysfunction in patients with COPD. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Computerized tomography using video recorded fluoroscopic images

    NASA Technical Reports Server (NTRS)

    Kak, A. C.; Jakowatz, C. V., Jr.; Baily, N. A.; Keller, R. A.

    1975-01-01

    A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.

  8. Multidetector computerized tomographic fistulography in the evaluation of congenital branchial cleft fistulae and sinuses.

    PubMed

    Sun, Zhipeng; Fu, Kaiyuan; Zhang, Zuyan; Zhao, Yanping; Ma, Xuchen

    2012-05-01

    The aim of this study was to primarily investigate the usefulness of computerized tomographic (CT) fistulography in the diagnosis and management of branchial cleft fistulae and sinuses. Fifteen patients with confirmed branchial fistulae or sinuses who had undergone CT fistulography were included. The diagnoses were confirmed by clinical, radiologic, or histopathologic examinations. The internal openings, distribution, and neighboring relationship of the lesions presented by CT fistulography were analyzed to evaluate the usefulness in comparison with x-ray fistulography. Nine patients were diagnosed with first branchial fistulae or sinuses, 2 with second branchial fistulae, and 4 with third or fourth branchial fistulae. The presence and location of the lesions could be seen on x-ray fistulography. The distribution of the lesions, internal openings, and neighboring relationship with parotid gland, carotid sheath, and submandibular gland could be clearly demonstrated on CT cross-sectional or volume-rendering images. CT fistulography could provide valuable information and benefit surgical planning by demonstrating the courses of branchial anomalies in detail. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Computerized tomography calibrator

    NASA Technical Reports Server (NTRS)

    Engel, Herbert P. (Inventor)

    1991-01-01

    A set of interchangeable pieces comprising a computerized tomography calibrator, and a method of use thereof, permits focusing of a computerized tomographic (CT) system. The interchangeable pieces include a plurality of nestable, generally planar mother rings, adapted for the receipt of planar inserts of predetermined sizes, and of predetermined material densities. The inserts further define openings therein for receipt of plural sub-inserts. All pieces are of known sizes and densities, permitting the assembling of different configurations of materials of known sizes and combinations of densities, for calibration (i.e., focusing) of a computerized tomographic system through variation of operating variables thereof. Rather than serving as a phanton, which is intended to be representative of a particular workpiece to be tested, the set of interchangeable pieces permits simple and easy standardized calibration of a CT system. The calibrator and its related method of use further includes use of air or of particular fluids for filling various openings, as part of a selected configuration of the set of pieces.

  10. [Evaluation of the risk of mediastinal or retroperitoneal injuries caused by dorso-lumbar pedicle screws].

    PubMed

    Hernigou, P; Germany, W

    1998-09-01

    Within an anatomical and a clinical study, the authors employed computerized tomographic scans to evaluate the risks of anterior surrounding tissues injuries during screw insertion. CT scans of 20 patients suffering from cardiac disease were reviewed retrospectively. Scans through the thoracic and lumbar spine were obtained using 6 mm slice thickness. These examinations were performed with intravenous contrast medium. Measurements of vessel diameters and distance of the soft tissues situated directly anterior to the spine were done. A retrospective study of 61 pedicle screws implanted for spine fractures evaluated the penetration of the anterior vertebral cordex with X rays and CT scans. Computerized tomographic scans of the thoracic and lumbar spine of the 20 patients in the control group confirmed proximity of the posterior mediastinal structures to the anterior vertebral cortex. Many structures of the posterior mediastinum were within five millimeters of the anterior vertebral cortex and thus were at risk: aorta, azygos vein, vena cava, parietal pleura and lungs. The theoretical risk of unrecognized screw penetrations evaluated on geometric shape of the anterior vertebral body is as high as 21 per cent when screw position is only seen with an antero posterior and a lateral X Ray. In the other group, computerized tomographic scans showed that 30 per cent of the implanted screws were outside the boundaries of the anterior thoracic spine. Two orthogonal incidences do not enable determination of whether the extremity of the screw is slightly outside the anterior cortex of the vertebral body. However the geometric shape of the anterior vertebral body enables peroperative definition of a safety zone on two orthogonal incidences. Even if a breach of a few millimeters of the anterior cortical boundaries of the vertebral body may not initially damage the adjacent soft-tissue structures, chronic irritation may result in late damages of these structures. The use of metallic markers and the respect of a safe vertebral zone on X Rays could guide the choice of the appropriate screw length.

  11. The influence of the periodontal biotype on peri-implant tissues around immediate implants with and without xenografts. Clinical and micro-computerized tomographic study in small Beagle dogs.

    PubMed

    Maia, Luciana P; Reino, Danilo M; Muglia, Valdir A; de Souza, Sérgio L S; Palioto, Daniela B; Novaes, Arthur B

    2015-01-01

    Soft tissues and buccal bone plate remodeling after immediate implantation in sockets with thin buccal bone, using the flapless approach with or without bone graft into the buccal gap, was compared between sites with thin and normal gingiva. Eight dogs had the gingiva of one side of the mandible thinned, the mandibular premolars were extracted without flaps, and 4 implants were installed in each side, positioned 1.5 mm from the buccal bone. The sites were randomly assigned into: TG (test group) = thin gingiva; TG + GM (TG with grafting material); CG (control group) = normal gingiva; and CG + GM (CG with grafting material). Buccal bone thickness (BBT), thickness of keratinized tissue (TKT), alveolar thickness (AT), gingival recession (GR), and probing depth (PD) were clinically evaluated. Within 12 weeks the dogs were sacrificed and the samples were analyzed by micro-computerized tomography. A thin BBT was observed in all the dogs. The presurgical procedures reduced TKT in the test group, with minimal changes of the AT. There were no statistically significant differences among the groups for the clinical parameters and the tomographic analysis showed similar linear and tri-dimensional bone reduction in all the groups. The thickness of the buccal bone was a fundamental factor in buccal bone plate resorption, even with flapless implantation. The decrease in gingival thickness or the addition of a biomaterial in the gap did not influence the results. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. An evaluation of the effectiveness of adaptive histogram equalization for contrast enhancement.

    PubMed

    Zimmerman, J B; Pizer, S M; Staab, E V; Perry, J R; McCartney, W; Brenton, B C

    1988-01-01

    Adaptive histogram equalization (AHE) and intensity windowing have been compared using psychophysical observer studies. Experienced radiologists were shown clinical CT (computerized tomographic) images of the chest. Into some of the images, appropriate artificial lesions were introduced; the physicians were then shown the images processed with both AHE and intensity windowing. They were asked to assess the probability that a given image contained the artificial lesion, and their accuracy was measured. The results of these experiments show that for this particular diagnostic task, there was no significant difference in the ability of the two methods to depict luminance contrast; thus, further evaluation of AHE using controlled clinical trials is indicated.

  13. Diagnosis of unsuspected facial fractures on routine head computerized tomographic scans in the unconscious multiply injured patient.

    PubMed

    Rehm, C G; Ross, S E

    1995-05-01

    This article assessed the value of routine head computerized axial tomographic (CT) scans for diagnosis of unsuspected facial fractures and its clinical implications in the multiply injured patient who is intubated, unconscious, or sedated at the time of initial assessment and requires a head CT scan to assess for brain injury. At a level I trauma center from June 1, 1992 to June 1, 1993 all intubated blunt trauma patients who required routine CT scan evaluation at initial assessment were studied prospectively. Routine scanning started at the foramen magnum and included the maxilla. Patients who died within the first 24 hours were excluded. The study population included 116 patients (85 male, 21 female) aged 12 to 85 years (mean, 28 years) with injury severity scores ranging from 1 to 50 (mean, 23). The mechanism of injury was: motor vehicle accidents (n = 74), motorcycling (n = 5), pedestrians accidents (n = 13), falls (n = 10), bicycling (n = 5), assaults (n = 8), and boating accident (n = 1). There were 19 suspected facial fractures; 18 required surgical repair. There were 27 unsuspected facial fractures; 13 required surgical care. Three suspected fractures were ruled out. Routine head CT scans to assess for brain injury in the multiply injured patient are also very useful in the diagnosis of unsuspected facial fractures, almost half of which will require surgical intervention.

  14. Redistribution of pulmonary blood flow impacts thermodilution-based extravascular lung water measurements in a model of acute lung injury

    PubMed Central

    Easley, R. Blaine; Mulreany, Daniel G.; Lancaster, Christopher T.; Custer, Jason W.; Fernandez-Bustamante, Ana; Colantuoni, Elizabeth; Simon, Brett A.

    2009-01-01

    Background Studies using transthoracic thermodilution have demonstrated increased extravascular lung water (EVLW) measurements attributed to progression of edema and flooding during sepsis and acute lung injury. We hypothesize that redistribution of pulmonary blood flow can cause increased apparent EVLW secondary to increased perfusion of thermally silent tissue, not increased lung edema. Methods Anesthetized, mechanically ventilated canines were instrumented with PiCCO® (Pulsion Medical, Munich, Germany) catheters and underwent lung injury by repetitive saline lavage. Hemodynamic and respiratory physiologic data were recorded. After stabilized lung injury, endotoxin was administered to inactivate hypoxic pulmonary vasoconstriction. Computerized tomographic imaging was performed to quantify in vivo lung volume, total tissue (fluid) and air content, and regional distribution of blood flow. Results Lavage injury caused an increase in airway pressures and decreased arterial oxygen content with minimal hemodynamic effects. EVLW and shunt fraction increased after injury and then markedly following endotoxin administration. Computerized tomographic measurements quantified an endotoxin-induced increase in pulmonary blood flow to poorly aerated regions with no change in total lung tissue volume. Conclusions The abrupt increase in EVLW and shunt fraction after endotoxin administration is consistent with inactivation of hypoxic pulmonary vasoconstriction and increased perfusion to already flooded lung regions that were previously thermally silent. Computerized tomographic studies further demonstrate in vivo alterations in regional blood flow (but not lung water) and account for these alterations in shunt fraction and EVLW. PMID:19809280

  15. [Imaging of temporo-mandibular disorders].

    PubMed

    Felizardo, Rufino; Foucart, Jean-Michel; Pizelle, Christophe

    2012-03-01

    Dominated for years by standard films (tomographic mouth open and mouth closed X-rays, MRI) radiographs of the TMJ have progressively lost their usefulness to diagnosticians who have progressively increased their reliance on well codified clinical examinations, which suffice in a great majority of cases.The indications for and diagnostic worth of radiological studies and the impact they have on the management of TMJ disorders are today quite low especially when the high cost of procedures like MRI, computerized tomography, and CBCT is taken into account. In this article we discuss the various maladies that dentists might encounter and the situations in which radiological examinations are still indicated. © EDP Sciences, SFODF, 2012.

  16. Childhood Psychosis and Computed Tomographic Brain Scan Findings.

    ERIC Educational Resources Information Center

    Gillberg, Christopher; Svendsen, Pal

    1983-01-01

    Computerized tomography (CT) of the brain was used to examine 27 infantile autistic children, 9 children with other kinds of childhood psychoses, 23 children with mental retardation, and 16 normal children. Gross abnormalities were seen in 26 percent of the autism cases. (Author/SEW)

  17. Detection of the source of hemorrhage using postmortem computerized tomographic angiography in a case of a giant juvenile nasopharyngeal angiofibroma after surgical treatment.

    PubMed

    do Nascimento, Felipe Barjud Pereira; dos Santos, Glaucia Aparecida Bento; Melo, Nelson Almeida d'Ávila; Damasceno, Eduarda Bittencourt; Mauad, Thais

    2015-09-01

    Postmortem computerized tomographic angiography (PMCTA) has been increasingly used in forensic medicine to detect and locate the source of bleeding in cases of fatal acute hemorrhage. In this paper, we report a case of postoperative complication in a patient with a giant juvenile nasopharyngeal angiofibroma in which the source of bleeding was detected by PMCTA. A case description and evaluations of the pre- and postoperative exams, postmortem CT angiogram, and conventional autopsy results are provided. The source of bleeding was identified by postmortem CT angiography but not by conventional autopsy. The established protocol, injecting contrast medium into the femoral artery, was effective in identifying the source of bleeding. Postoperative bleeding is a rare and frequently fatal complication of juvenile nasopharyngeal angiofibroma. As a complement to conventional autopsy, postmortem angiography is a valuable tool for the detection of lethal acute hemorrhagic foci, and establishing a routine procedure for PMCTA may improve its efficiency.

  18. Osmotic blood-brain barrier disruption. Computerized tomographic monitoring of chemotherapeutic agent delivery.

    PubMed Central

    Neuwelt, E A; Maravilla, K R; Frenkel, E P; Rapaport, S I; Hill, S A; Barnett, P A

    1979-01-01

    The present study describes a canine model of transient reversible blood-brain barrier disruption with hyperosmolar mannitol infusion into the internal carotid artery. Studies in this model show that osmotic blood-brain barrier disruption before intracarotid infusion of methotrexate results in markedly elevated (therapeutic) levels of drug in the ipsilateral cerebral hemisphere. Levels in the cerebrospinal fluid correlate poorly and inconsistently with brain levels. Computerized tomograms in this canine model provide a noninvasive monitor of the degree, time-course, and localization of osmotic blood-brain barrier disruption. Images PMID:457877

  19. CMT for materials science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinney, J.

    This session is comprised of two articles by John Kinney describing biomedical and other uses for computerized tomography. In the first article, Kinney describes the use of a three-dimensional x-ray tomographic microscope to image the trabecular bone architecture of the proximal tibias of rats in vivo. Research in this field may help to detect the earliest stages of hypoestrogenemic bone loss and may help to more rapidly test the effectiveness of new clinical treatments for this major public health problem. The second article describes recent advances in X-ray tomography using synchrotron radiation to evaluate microstructures in ceramic matrix composites, bonemore » loss in osteoporosis, and the development of carries lesions in teeth.« less

  20. CMT for biomedical and other applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spanne, P.

    This session includes two presentations describing applications for x-ray tomography using synchrotron radiation for biomedical uses and fluid flow modeling, and outlines advantages for using monoenergetic x-rays. Contrast mechanisms are briefly described and several graphs of absorbed doses and scattering of x-rays are included. Also presented are schematic diagrams of computerized tomographic instrumentation with camera head. A brief description of goals for a real time tomographic system and expected improvements to the system are described. Color photomicrographs of the Berea Sandstone and human bone are provided, as well as a 3-D microtomographic reconstruction of a human vertebra sample.

  1. Thoracic computerized tomographic (CT) findings in 2009 influenza A (H1N1) virus infection in Isfahan, Iran

    PubMed Central

    Rostami, Mojtaba; Javadi, Abbas-Ali; Khorvash, Farzin; Mostafavizadeh, Kamyar; Adibi, Atoosa; Babak, Anahita; Ataei, Behrooz; Meidani, Mohsen; Naeini, Alireza Emami; Salehi, Hasan; Avijgan, Majid; Yazdani, Mohammad Reza; Rezaei, Farshid

    2011-01-01

    BACKGROUND: Pandemic 2009 H1N1 influenza A virus arrived at Isfahan in August 2009. The virus is still circulating in the world. The abnormal thoracic computerized tomographic (CT) scan findings vary widely among the studies of 2009 H1N1 influenza. We evaluated the thoracic CT findings in patients with 2009 H1N1 virus infection to describe findings compared to previously reported findings, and to suggest patterns that may be suggestive for 2009 influenza A (H1N1) in an appropriate clinical setting. METHODS: Retrospectively, the archive of all patients with a diagnosis of 2009 H1N1 influenza A were reviewed, in Al-Zahra Hospital in Isfahan, central Iran, between September 23rd 2009 to February 20th 2010. Out of 216 patients with confirmed 2009 influenza A (H1N1) virus, 26 cases with abnormal CT were enrolled in the study. Radiologic findings were characterized by the type and pattern of opacities and zonal distribution. RESULTS: Patchy infiltration (34.6%), lobar consolidation (30.8%), and interstitial infiltration (26.9%) with airbronchogram (38.5%) were the predominant findings in our patients. Bilateral distribution was seen in 80.8% of the patients. Only one patient (3.8%) showed ground-glass opacity, predominant radiographic finding in the previous reports and severe acute respiratory syndrome (SARS). CONCLUSIONS: The most common thoracic CT findings in pandemic H1N1 were patchy infiltration, lobar consolidation, and interstitial infiltration with airbronchogram and bilateral distribution. While these findings can be associated with other infections; they may be suggestive to 2009 influenza A (H1N1) in the appropriate clinical setting. Various radiographic patterns can be seen in thoracic CT scans of the influenza patients. Imaging findings are nonspecific. PMID:22091280

  2. [The role of multidetector computer tomography in diagnosis of acute pancreatitis].

    PubMed

    Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M

    2014-10-01

    With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.

  3. The economic potential of CT scanners for hardwood sawmills

    Treesearch

    Donald G. Hodges; Walter C. Anderson; Charles W. McMillin

    1990-01-01

    Research has demonstrated that a knowledge of internal log defects prior to sawing could improve lumber value yields significantly. This study evaluated the potential economic returns from investments in computerized tomographic (CT) scanners to detect internal defects in hardwood logs at southern sawmills. The results indicate that such investments would be profitable...

  4. The neurologic evaluation of patients with low-tension glaucoma.

    PubMed

    Corbett, J J; Phelps, C D; Eslinger, P; Montague, P R

    1985-08-01

    One hypothesized cause of low-tension glaucoma is chronic or intermittent ischemia of the optic nerve. Since the optic nerve and brain are both parts of the central nervous system and share a common blood supply, the authors wondered if patients with low-tension glaucoma might also have clinical or radiographic evidence of cerebral atrophy. In this study, 27 patients with low-tension glaucoma were examined using neurobehavioral testing, electroencephalography, computerized tomographic scan, neurological history, and physical examination. In only a small number of patients were these tests abnormal. However, 12 of the 27 patients gave a history of common or classic migraine. This unexpected finding raises the possibility that migraine-related ischemia might be the pathogenic mechanism in some cases of low-tension glaucoma.

  5. A 5-year clinical and computerized tomographic implant follow-up in sinus-lifted maxillae and native bone.

    PubMed

    Sbordone, Carolina; Toti, Paolo; Ramaglia, Luca; Guidetti, Franco; Sbordone, Ludovico; Martuscelli, Ranieri

    2014-09-01

    The present study analysed apical and marginal bone remodelling around dental implants placed in both maxillary (sinus elevated with particulated autogenous osseous graft) and corresponding native bone areas, with a follow-up of 5 years. The clinical survival of implants was also observed. In this retrospective chart review, 27 patients were enrolled, with 55 dental implants inserted from 2000 to 2006, 26 of which were followed (one implant per patient); if required, patients were treated via sinus lift with autogenous bone and particulate technique. The internal controls were implants positioned in native areas beneath the sinus. Radiologic survey was assessed via computerized tomographic analysis measuring apical bone level (ABL) and marginal bone level (MBL), at 1- (T1 ), 3- (T2 ) and 5 years (T3 ), around implants (buccal, b; palatal, p; mesial, m; and distal sides, d). Clinical probing depth (CPD) and clinical attachment level (CAL) for all the four peri-implant aspects were measured. Cumulative survival rate (CSR) and survival rate (SR) of implants were calculated. Significances for paired and unpaired comparisons were searched for. A significant degree of apical resorption was recorded between T1 and T3 for the mesial particulate group; again, a significant difference was discovered between the native and particulate procedures for mABL. A further feature was discovered for the particulate procedure, for which ABLs resulted negative at least for three of the aspects. Regarding MBL measurements, similar behaviours were revealed using time-comparison analysis for the two procedures at the buccal aspect. Comparisons among diameters, irrespective of the procedure, showed that resorption times for the bMBL were shorter as the diameter of the implant became wider. The implant CSR was 92% in native areas (two failures/25 implants) and 93.3% in sinuses lifted with particulate bone (two failures/30 implants). The results suggest that a protrusion of the implant apices into augmented sinus lift occurred, whereas the bone remodelling of the coronal areas was not influenced by the events in the maxillary sinus. A diameter ranging from 4 to 5 mm might better guarantee a conservation of marginal peri-implant bone level compared with implants with smaller diameters. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. X-ray tomographic image magnification process, system and apparatus therefor

    DOEpatents

    Kinney, J.H.; Bonse, U.K.; Johnson, Q.C.; Nichols, M.C.; Saroyan, R.A.; Massey, W.N.; Nusshardt, R.

    1993-09-14

    A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: (a) source means for providing a source of parallel x-ray beams, (b) staging means for staging and sequentially rotating a sample to be positioned in the path of the (c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, (d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and (e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor. 25 figures.

  7. X-ray tomographic image magnification process, system and apparatus therefor

    DOEpatents

    Kinney, John H.; Bonse, Ulrich K.; Johnson, Quintin C.; Nichols, Monte C.; Saroyan, Ralph A.; Massey, Warren N.; Nusshardt, Rudolph

    1993-01-01

    A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: a) source means for providing a source of parallel x-ray beams, b) staging means for staging and sequentially rotating a sample to be positioned in the path of the c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor.

  8. Use of radiologic modalities in coccidioidal meningitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Goldstein, E.; Hoeprich, P.D.

    1981-01-01

    The diagnostic utility of pentetate indium trisodium CSF studies, technetium Tc 99m brain scans, and computerized tomographic (CT) scans was evaluated in eight patients in whom coccidioidal meningitis developed following a dust storm in the Central Valley of California. The 111In flow studies and the CT scans demonstrated hydrocephalus in five patients with clinical findings suggesting this complication. Ventriculitis has not previously been diagnosed before death in patients with coccidioidal meningitis; however, it was demonstrated in two patients by the technetium Tc 99m brain scan. The finding that communicating hydrocephalus occurs early in meningitis and interferes with CSF flow intomore » infected basilar regions has important therapeutic implications in that antifungal agents injected into the lumbar subarachnoid space may not reach these regions.« less

  9. Anthropometric and computerized tomographic measurements of lower extremity lean body mass.

    PubMed

    Buckley, D C; Kudsk, K A; Rose, B S; Fatzinger, P; Koetting, C A; Schlatter, M

    1987-02-01

    The loss of lean muscle mass is one of the hallmarks of protein-calorie malnutrition. Anthropometry is a standardized technique used to assess the response of muscle mass to nutrition therapy by quantifying the muscle and fat compartments. That technique does not accurately reflect actual limb composition, whereas computerized tomography does. Twenty lower extremities on randomly chosen men and women patients were evaluated by anthropometry and computerized tomography. Total area, muscle plus bone area, total volume, and muscle plus bone volume were correlated, using Heymsfield's equation and computerized tomography-generated areas. Anthropometrics overestimated total and muscle plus bone cross-sectional areas at almost every level. Anthropometry overestimated total area and total volume by 5% to 10% but overestimated muscle plus bone area and muscle plus bone volume by as much as 40%. Anthropometry, while easily performed and useful in large population groups for epidemiological studies, offers a poor assessment of lower extremity composition. On the other hand, computerized tomography is also easily performed and, while impractical for large population groups, does offer an accurate assessment of the lower extremity tissue compartments and is an instrument that might be used in research on lean muscle mass.

  10. PubMed Central

    Laplante, L; Everett, J

    1992-01-01

    Many attempts to isolate a dysfunctional site in the brain of schizophrenic patients have converged in a neuropathological conception of the disease based on frontal lobe hypoactivity. Recent data from studies using cytoarchitectony, computerized tomographic scans, cerebral regional blood flow, smooth pursuit eye movements and neuropsychological assessments are discussed. Current data on the hypofrontality hypothesis in schizophrenia seem to suggest an associationist rather than a localisationist perspective of the disorder. PMID:1489762

  11. Computed Tomography Status

    DOE R&D Accomplishments Database

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  12. Ultrafast CT scanning of an oak log for internal defects

    Treesearch

    Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder

    1989-01-01

    Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...

  13. Computerized tomographic determination of spinal bone mineral content

    NASA Technical Reports Server (NTRS)

    Cann, C. E.; Genant, H. K.

    1980-01-01

    The aims of the study were three-fold: to determine the magnitude of vertebral cancellous mineral loss in normal subjects during bedrest, to compare this loss with calcium balance and mineral loss in peripheral bones, and to use the vertebral measurements as an evaluative criterion for the C12MDP treatment and compare it with other methods. The methods used are described and the results from 14 subjects are presented.

  14. Critical factors influencing physicians' intention to use computerized clinical practice guidelines: an integrative model of activity theory and the technology acceptance model.

    PubMed

    Hsiao, Ju-Ling; Chen, Rai-Fu

    2016-01-16

    With the widespread use of information communication technologies, computerized clinical practice guidelines are developed and considered as effective decision supporting tools in assisting the processes of clinical activities. However, the development of computerized clinical practice guidelines in Taiwan is still at the early stage and acceptance level among major users (physicians) of computerized clinical practice guidelines is not satisfactory. This study aims to investigate critical factors influencing physicians' intention to computerized clinical practice guideline use through an integrative model of activity theory and the technology acceptance model. The survey methodology was employed to collect data from physicians of the investigated hospitals that have implemented computerized clinical practice guidelines. A total of 505 questionnaires were sent out, with 238 completed copies returned, indicating a valid response rate of 47.1 %. The collected data was then analyzed by structural equation modeling technique. The results showed that attitudes toward using computerized clinical practice guidelines (γ = 0.451, p < 0.001), organizational support (γ = 0.285, p < 0.001), perceived usefulness of computerized clinical practice guidelines (γ = 0.219, p < 0.05), and social influence (γ = 0.213, p < 0.05) were critical factors influencing physicians' intention to use computerized clinical practice guidelines, and these factors can explain 68.6 % of the variance in intention to use computerized clinical practice guidelines. This study confirmed that some subject (human) factors, environment (organization) factors, tool (technology) factors mentioned in the activity theory should be carefully considered when introducing computerized clinical practice guidelines. Managers should pay much attention on those identified factors and provide adequate resources and incentives to help the promotion and use of computerized clinical practice guidelines. Through the appropriate use of computerized clinical practice guidelines, the clinical benefits, particularly in improving quality of care and facilitating the clinical processes, will be realized.

  15. Experience with single photon emission computerized tomography (SPECT) in follow-up of sternotomy healing.

    PubMed

    Harjula, A; Järvinen, A; Mattila, S; Porkka, L

    1985-01-01

    Single photon emission computerized tomography (SPECT) was performed thrice in ten patients undergoing open-heart surgery--preoperatively and 2 and 12 weeks postoperatively. The operations were done for ischemic heart disease (5), aortic valvular stenosis (2), aortic valvular insufficiency (1), leaking mitral prosthetic valve (1) and combined aortic and mitral valvular stenosis and insufficiency (1). The healing process in the longitudinally divided sternum was evaluated from the SPECT study. Four conventional static images in two dimensions were registered in anteroposterior, posteroanterior and left and right lateral projections. A tomographic study was done. Quantitative analyses were performed. The ratio of the sternal counts to the counts from a thoracic vertebra was calculated for use as a reference. The activity ratios showed a similar pattern in six cases, with initial increases and at 12 weeks slight decrease compared with the preoperative values. In two cases the activity was still increasing after 12 postoperative weeks. One patient, with sternotomy also one year previously, showed only slightly increased activity. The activity at the areas of the sternal wires was increased in six cases. The study thus revealed differing patterns of isotope uptake, although recovery was uneventful in all patients. The differences may reflect the possibility that the operative course and the preoperative clinical status can influence the healing mechanisms.

  16. Assessment of Severity of Ovine Smoke Inhalation Injury by Analysis of Computed Tomographic Scans

    DTIC Science & Technology

    2003-09-01

    Computerized analysis of three- dimensional reconstructed scans was also performed, based on Hounsfield unit ranges: hyperinflated, 1,000 to 900; normal...the interactive segmentation function of the software. The pulmonary parenchyma was separated into four regions based on the Hounsfield unit (HU...SII) severity. Methods: Twenty anesthetized sheep underwent graded SII: group I, no smoke; group II, 5 smoke units ; group III, 10 units ; and group IV

  17. Research on ionospheric tomography based on variable pixel height

    NASA Astrophysics Data System (ADS)

    Zheng, Dunyong; Li, Peiqing; He, Jie; Hu, Wusheng; Li, Chaokui

    2016-05-01

    A novel ionospheric tomography technique based on variable pixel height was developed for the tomographic reconstruction of the ionospheric electron density distribution. The method considers the height of each pixel as an unknown variable, which is retrieved during the inversion process together with the electron density values. In contrast to conventional computerized ionospheric tomography (CIT), which parameterizes the model with a fixed pixel height, the variable-pixel-height computerized ionospheric tomography (VHCIT) model applies a disturbance to the height of each pixel. In comparison with conventional CIT models, the VHCIT technique achieved superior results in a numerical simulation. A careful validation of the reliability and superiority of VHCIT was performed. According to the results of the statistical analysis of the average root mean square errors, the proposed model offers an improvement by 15% compared with conventional CIT models.

  18. TomoPhantom, a software package to generate 2D-4D analytical phantoms for CT image reconstruction algorithm benchmarks

    NASA Astrophysics Data System (ADS)

    Kazantsev, Daniil; Pickalov, Valery; Nagella, Srikanth; Pasca, Edoardo; Withers, Philip J.

    2018-01-01

    In the field of computerized tomographic imaging, many novel reconstruction techniques are routinely tested using simplistic numerical phantoms, e.g. the well-known Shepp-Logan phantom. These phantoms cannot sufficiently cover the broad spectrum of applications in CT imaging where, for instance, smooth or piecewise-smooth 3D objects are common. TomoPhantom provides quick access to an external library of modular analytical 2D/3D phantoms with temporal extensions. In TomoPhantom, quite complex phantoms can be built using additive combinations of geometrical objects, such as, Gaussians, parabolas, cones, ellipses, rectangles and volumetric extensions of them. Newly designed phantoms are better suited for benchmarking and testing of different image processing techniques. Specifically, tomographic reconstruction algorithms which employ 2D and 3D scanning geometries, can be rigorously analyzed using the software. TomoPhantom also provides a capability of obtaining analytical tomographic projections which further extends the applicability of software towards more realistic, free from the "inverse crime" testing. All core modules of the package are written in the C-OpenMP language and wrappers for Python and MATLAB are provided to enable easy access. Due to C-based multi-threaded implementation, volumetric phantoms of high spatial resolution can be obtained with computational efficiency.

  19. [X-ray computed tomographic abnormalities in schizophrenia. Trial of relationship with clinical data].

    PubMed

    D'Amato, T; Rochet, T; Dalery, J; Chauchat, J H; Terra, J L; Arteaga, C; Marie-Cardine, M

    1992-01-01

    Computerized tomography (CT-scan) studies in schizophrenia revealed that some patients have neuromorphological abnormalities. The structural changes consist mainly in lateral and third ventricle enlargement, and in cortical atrophy. The present study evaluates these three changes in 42 schizophrenics aged 18 to 50, compared to 24 healthy controls. Diagnosis were established from information gathered by personal interview with the SADS-LA. Clinical sub-types were evaluated according to the DSM III-R criteria. Moreover, detailed symptoms were rated according to the Positive And Negative Syndrome Scale (PANSS). CT scans were recorded in floppy disks and blindly analyzed. Schizophrenics shown significant higher mean size of lateral and third ventricles, and higher mean anterior cortical atrophy than healthy subjects. Significant differences were also found between subtypes, with more marked abnormalities in the disorganized group. The relationship between brain abnormalities and clinical symptoms recorded with the PANSS, were analysed using Pearson correlates. Positive correlations concerned mainly negative symptoms like blunted affect, emotional withdrawal, difficulties in abstract thinking, passive apathetic social withdrawal and lack of spontaneity of conversation. Positive correlations are also observed with some symptoms classified with the PANSS in the General Psychopathology scale such as mannerism and disorientation. Negative correlation concerned most of PANSS positive symptoms.

  20. CT colonography with reduced bowel preparation after incomplete colonoscopy in the elderly.

    PubMed

    Iafrate, F; Hassan, C; Zullo, A; Stagnitti, A; Ferrari, R; Spagnuolo, A; Laghi, A

    2008-07-01

    We prospectively assessed the feasibility and acceptance of computerized tomographic colonography (CTC) without bowel cathartic preparation in elderly patients after incomplete colonoscopy. A total of 136 patients underwent CTC without cathartic preparation. The time delay between conventional colonoscopy and CTC ranged between 3 and 20 days, depending on the clinical situation. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. CTCs were interpreted using a primary two-dimensional (2D) approach and 3D images for further characterization. Patients were interviewed before and 2 weeks after CTC to assess preparation acceptance. CTC was feasible and technically successful in all the 136 patients. Fecal tagging was judged as excellent in 113 (83%) patients and sufficient in 23 (17%). Average CT image interpretation time was 14.8 min. Six (4.4%) cases of colorectal cancer and nine (6.6%) large polyps were detected, as well as 23 (11.3%) extracolonic findings of high clinical importance. No major side effect occurred, although 25% patients reported minor side effects, especially diarrhea. Overall, 76/98 patients replied that they would be willing to repeat the test if necessary. CTC without cathartic preparation is a technically feasible and safe procedure to complete a colonic study in the elderly, prompting its use in clinical practice.

  1. Creation of virtual patients from CT images of cadavers to enhance integration of clinical and basic science student learning in anatomy.

    PubMed

    Jacobson, Stanley; Epstein, Scott K; Albright, Susan; Ochieng, Joseph; Griffiths, Jeffrey; Coppersmith, Veronica; Polak, Joseph F

    2009-08-01

    The goal of this study was to determine whether computerized tomographic (CT) images of cadavers could be used in addition to images from patients to develop virtual patients (VPs) to enhance integrated learning of basic and clinical science. We imaged 13 cadavers on a Siemens CT system. The DICOM images from the CT were noted to be of high quality by a radiologist who systematically identified all abnormal and pathological findings. The pathological findings from the CT images and the cause of death were used to develop plausible clinical cases and study questions. Each case was designed to highlight and explain the abnormal anatomic findings encountered during the cadaveric dissection. A 3D reconstruction was produced using OsiriX and then formatted into a QuickTime movie which was then stored on the Tufts University Sciences Knowledgebase (TUSK) as a VP. We conclude that CT scanning of cadavers produces high-quality images that can be used to develop VPs. Although the use of the VPs was optional and fewer than half of the students had an imaged cadaver for dissection, 59 of the 172 (34%) students accessed and reviewed the cases and images positively and were very encouraging for us to continue.

  2. Clinical, radiographic, ultrasonographic and computed tomographic features of nonseptic osteitis of the axial border of the proximal sesamoid bones.

    PubMed

    Vanderperren, K; Bergman, H J; Spoormakers, T J P; Pille, F; Duchateau, L; Puchalski, S M; Saunders, J H

    2014-07-01

    Lysis of the axial aspect of equine proximal sesamoid bones (PSBs) is a rare condition reported to have septic or traumatic origins. Limited information exists regarding imaging of nonseptic axial osteitis of a PSB. To report the clinical, radiographic, ultrasonographic, computed tomographic and intra-arterial contrast-enhanced computed tomographic abnormalities in horses with axial nonseptic osteitis of a PSB. Retrospective clinical study. Eighteen horses diagnosed with nonseptic osteitis of the axial border of a PSB between 2007 and 2012 were reviewed retrospectively. Case details, clinical examination, radiographic, ultrasonographic, computed tomographic and intra-arterial/intra-articular contrast-enhanced computed tomographic features were recorded, when available. Radiographic, ultrasonographic and computed tomographic evaluations of the fetlock region had been performed on 18, 15 and 9 horses, respectively. The effect of the degree of lysis on the grade and duration of lameness was determined. All horses had chronic unilateral lameness, 4 with forelimb and 14 with hindlimb signs. On radiographs, lysis was identified in both PSBs in 14 horses, one PSB in 3 horses and in one horse no lysis was identified. The degree of osteolysis was variable. Ultrasonography identified variably sized irregularities of the bone surface and alteration in echogenicity of the palmar/plantar ligament (PL). All horses undergoing computed tomographic examination (n = 9) had biaxial lysis. The lesions were significantly longer and deeper on computed tomographic images compared with radiographic images. Intra-arterial contrast-enhanced computed tomography may reveal moderate to marked contrast enhancement of the PL. There was no significant effect of the degree of lysis on the grade and duration of lameness. Lesions of nonseptic axial osteitis of a PSB can be identified using a combination of radiography and ultrasonography. Computed tomography provides additional information regarding the extent of the pathology. © 2013 EVJ Ltd.

  3. New developments in multimodal clinical multiphoton tomography

    NASA Astrophysics Data System (ADS)

    König, Karsten

    2011-03-01

    80 years ago, the PhD student Maria Goeppert predicted in her thesis in Goettingen, Germany, two-photon effects. It took 30 years to prove her theory, and another three decades to realize the first two-photon microscope. With the beginning of this millennium, first clinical multiphoton tomographs started operation in research institutions, hospitals, and in the cosmetic industry. The multiphoton tomograph MPTflexTM with its miniaturized flexible scan head became the Prism-Award 2010 winner in the category Life Sciences. Multiphoton tomographs with its superior submicron spatial resolution can be upgraded to 5D imaging tools by adding spectral time-correlated single photon counting units. Furthermore, multimodal hybrid tomographs provide chemical fingerprinting and fast wide-field imaging. The world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph in spring 2010. In particular, nonfluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen have been imaged in patients with dermatological disorders. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution imaging tools such as ultrasound, optoacoustic, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer (malignant melanoma), optimization of treatment strategies (wound healing, dermatitis), and cosmetic research including long-term biosafety tests of ZnO sunscreen nanoparticles and the measurement of the stimulated biosynthesis of collagen by anti-ageing products.

  4. A computerized clinical decision support system as a means of implementing depression guidelines.

    PubMed

    Trivedi, Madhukar H; Kern, Janet K; Grannemann, Bruce D; Altshuler, Kenneth Z; Sunderajan, Prabha

    2004-08-01

    The authors describe the history and current use of computerized systems for implementing treatment guidelines in general medicine as well as the development, testing, and early use of a computerized decision support system for depression treatment among "real-world" clinical settings in Texas. In 1999 health care experts from Europe and the United States met to confront the well-documented challenges of implementing treatment guidelines and to identify strategies for improvement. They suggested the integration of guidelines into computer systems that is incorporated into clinical workflow. Several studies have demonstrated improvements in physicians' adherence to guidelines when such guidelines are provided in a computerized format. Although computerized decision support systems are being used in many areas of medicine and have demonstrated improved patient outcomes, their use in psychiatric illness is limited. The authors designed and developed a computerized decision support system for the treatment of major depressive disorder by using evidence-based guidelines, transferring the knowledge gained from the Texas Medication Algorithm Project (TMAP). This computerized decision support system (CompTMAP) provides support in diagnosis, treatment, follow-up, and preventive care and can be incorporated into the clinical setting. CompTMAP has gone through extensive testing to ensure accuracy and reliability. Physician surveys have indicated a positive response to CompTMAP, although the sample was insufficient for statistical testing. CompTMAP is part of a new era of comprehensive computerized decision support systems that take advantage of advances in automation and provide more complete clinical support to physicians in clinical practice.

  5. Current developments in clinical multiphoton tomography

    NASA Astrophysics Data System (ADS)

    König, Karsten; Weinigel, Martin; Breunig, Hans Georg; Gregory, Axel; Fischer, Peter; Kellner-Höfer, Marcel; Bückle, Rainer

    2010-02-01

    Two-photon microscopy has been introduced in 1990 [1]. 13 years later, CE-marked clinical multiphoton systems for 3D imaging of human skin with subcellular resolution have been launched by the JenLab company with the tomograph DermaInspectTM. In 2010, the second generation of clinical multiphoton tomographs was introduced. The novel mobile multiphoton tomograph MPTflexTM, equipped with a flexible articulated optical arm, provides an increased flexibility and accessibility especially for clinical and cosmetical examinations. The multiphoton excitation of fluorescent biomolecules like NAD(P)H, flavins, porphyrins, elastin, and melanin as well as the second harmonic generation of collagen is induced by picojoule femtosecond laser pulses from an tunable turn-key near infrared laser system. The ability for rapid highquality image acquisition, the user-friendly operation of the system, and the compact and flexible design qualifies this system to be used for melanoma detection, diagnostics of dermatological disorders, cosmetic research, and skin aging measurements as well as in situ drug monitoring and animal research. So far, more than 1,000 patients and volunteers have been investigated with the multiphoton tomographs in Europe, Asia, and Australia.

  6. Peritoneal mesothelioma presenting as an acute surgical abdomen due to jejunal perforation.

    PubMed

    Salemis, Nikolaos S; Tsiambas, Evangelos; Gourgiotis, Stavros; Mela, Ageliki; Karameris, Andreas; Tsohataridis, Efstathios

    2007-11-01

    Peritoneal mesothelioma is a rare disease associated with poor prognosis. Acute abdomen as the first presentation is an extremely rare occurrence. We report an exceptional case of a patient who was found to have a jejunal perforation due to infiltration of peritoneal mesothelioma. A 62-year-old man was admitted with clinical signs of peritonitis. Computerized tomographic scans showed a mass distal to the ligament of Treitz, thickening of the mesentery and a small amount of ascites. Emergency laparotomy revealed a perforated tumor 15 cm distal to the ligament of Treitz and diffuse peritoneal disease. Segmental small bowel resection and suboptimal cytoreduction were performed. Histopathology and immunohistochemistry showed infiltration of malignant mesothelioma. During the postoperative period pleural mesothelioma was also diagnosed. Despite adjuvant chemotherapy, the patient died of disseminated progressive disease 7 months after surgery. Peritoneal mesothelioma is a rare malignancy with grim prognosis. Small bowel involvement is a poor prognostic indicator. Our case of a small bowel perforation due to direct infiltration by peritoneal mesothelioma appears to be the first reported in the English literature.

  7. High-resolution multimodal clinical multiphoton tomography of skin

    NASA Astrophysics Data System (ADS)

    König, Karsten

    2011-03-01

    This review focuses on multimodal multiphoton tomography based on near infrared femtosecond lasers. Clinical multiphoton tomographs for 3D high-resolution in vivo imaging have been placed into the market several years ago. The second generation of this Prism-Award winning High-Tech skin imaging tool (MPTflex) was introduced in 2010. The same year, the world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph. In particular, non-fluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen has been imaged with submicron resolution in patients suffering from psoriasis. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution wide-field systems such as ultrasound, optoacoustical, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer, optimization of treatment strategies, and cosmetic research including long-term testing of sunscreen nanoparticles as well as anti-aging products.

  8. [Computerized acquisition and elaboration of clinical data in Rheumatology during ten years: state of art and prospectives

    PubMed

    Troise Rioda, W.; Nervetti, A.

    2001-01-01

    The well known complexity to collect the clinical data of patients and in particular in the area of rheumatology push us to develop a computerized clinical chart in order to facilitate the classification, evaluation and monitoring of these patients. The proposed computerized clinical chart is easy to use but at the same time is a very potent tool that allow the clinicians to organize the classic rheumatological pathologies as well as the more complexes or even rare. The proposed clinical chart is based on a relational database (FileMaker Pro 5.0v1) available for both the actual operative systems implemented on personal computers (Windows and Macintosh); this allow the full compatibility among the two systems, the possibility of exchanging data without any loss of information. The computerized clinical chart is structured on modules for specific pathologies and for homogeneous groups of illnesses. Basically the modules are defined correlated files of data for a specific pathology but that can be used also as a common pool for different pathologies. Our experience, based on ten years of use, indicates in the computerized rheumatological clinical chart an indispensable tool for rheumatologists with a real friendly use.

  9. Pseudo-shading technique in the two-dimensional domain: a post-processing algorithm for enhancing the Z-buffer of a three-dimensional binary image.

    PubMed

    Tan, A C; Richards, R

    1989-01-01

    Three-dimensional (3D) medical graphics is becoming popular in clinical use on tomographic scanners. Research work in 3D reconstructive display of computerized tomography (CT) and magnetic resonance imaging (MRI) scans on conventional computers has produced many so-called pseudo-3D images. The quality of these images depends on the rendering algorithm, the coarseness of the digitized object, the number of grey levels and the image screen resolution. CT and MRI data are fundamentally voxel based and they produce images that are coarse because of the resolution of the data acquisition system. 3D images produced by the Z-buffer depth shading technique suffer loss of detail when complex objects with fine textural detail need to be displayed. Attempts have been made to improve the display of voxel objects, and existing techniques have shown the improvement possible using these post-processing algorithms. The improved rendering technique works on the Z-buffer image to generate a shaded image using a single light source in any direction. The effectiveness of the technique in generating a shaded image has been shown to be a useful means of presenting 3D information for clinical use.

  10. Computerized neurocognitive testing in the management of sport-related concussion: an update.

    PubMed

    Resch, Jacob E; McCrea, Michael A; Cullum, C Munro

    2013-12-01

    Since the late nineties, computerized neurocognitive testing has become a central component of sport-related concussion (SRC) management at all levels of sport. In 2005, a review of the available evidence on the psychometric properties of four computerized neuropsychological test batteries concluded that the tests did not possess the necessary criteria to warrant clinical application. Since the publication of that review, several more computerized neurocognitive tests have entered the market place. The purpose of this review is to summarize the body of published studies on psychometric properties and clinical utility of computerized neurocognitive tests available for use in the assessment of SRC. A review of the literature from 2005 to 2013 was conducted to gather evidence of test-retest reliability and clinical validity of these instruments. Reviewed articles included both prospective and retrospective studies of primarily sport-based adult and pediatric samples. Summaries are provided regarding the available evidence of reliability and validity for the most commonly used computerized neurocognitive tests in sports settings.

  11. A cost-utility analysis of the use of preoperative computed tomographic angiography in abdomen-based perforator flap breast reconstruction.

    PubMed

    Offodile, Anaeze C; Chatterjee, Abhishek; Vallejo, Sergio; Fisher, Carla S; Tchou, Julia C; Guo, Lifei

    2015-04-01

    Computed tomographic angiography is a diagnostic tool increasingly used for preoperative vascular mapping in abdomen-based perforator flap breast reconstruction. This study compared the use of computed tomographic angiography and the conventional practice of Doppler ultrasonography only in postmastectomy reconstruction using a cost-utility model. Following a comprehensive literature review, a decision analytic model was created using the three most clinically relevant health outcomes in free autologous breast reconstruction with computed tomographic angiography versus Doppler ultrasonography only. Cost and utility estimates for each health outcome were used to derive the quality-adjusted life-years and incremental cost-utility ratio. One-way sensitivity analysis was performed to scrutinize the robustness of the authors' results. Six studies and 782 patients were identified. Cost-utility analysis revealed a baseline cost savings of $3179, a gain in quality-adjusted life-years of 0.25. This yielded an incremental cost-utility ratio of -$12,716, implying a dominant choice favoring preoperative computed tomographic angiography. Sensitivity analysis revealed that computed tomographic angiography was costlier when the operative time difference between the two techniques was less than 21.3 minutes. However, the clinical advantage of computed tomographic angiography over Doppler ultrasonography only showed that computed tomographic angiography would still remain the cost-effective option even if it offered no additional operating time advantage. The authors' results show that computed tomographic angiography is a cost-effective technology for identifying lower abdominal perforators for autologous breast reconstruction. Although the perfect study would be a randomized controlled trial of the two approaches with true cost accrual, the authors' results represent the best available evidence.

  12. Combined single photon emission computerized tomography and conventional computerized tomography: Clinical value for the shoulder surgeons?

    PubMed Central

    Hirschmann, Michael T.; Schmid, Rahel; Dhawan, Ranju; Skarvan, Jiri; Rasch, Helmut; Friederich, Niklaus F.; Emery, Roger

    2011-01-01

    With the cases described, we strive to introduce single photon emission computerized tomography in combination with conventional computer tomography (SPECT/CT) to shoulder surgeons, illustrate the possible clinical value it may offer as new diagnostic radiologic modality, and discuss its limitations. SPECT/CT may facilitate the establishment of diagnosis, process of decision making, and further treatment for complex shoulder pathologies. Some of these advantages were highlighted in cases that are frequently seen in most shoulder clinics. PMID:22058640

  13. D-dimer threshold increase with pretest probability unlikely for pulmonary embolism to decrease unnecessary computerized tomographic pulmonary angiography

    PubMed Central

    Hogg, Melanie M.; Courtney, D. Mark; Miller, Chadwick D.; Jones, Alan E.; Smithline, Howard A

    2012-01-01

    Background Increasing the threshold to define a positive D-dimer could reduce unnecessary computed tomographic pulmonary angiography (CTPA) for suspected PE but might increase rates of missed PE and missed pneumonia, the most common nonthromboembolic diagnosis seen on CTPA. Objective Measure the effect of doubling the standard D-dimer threshold for “PE unlikely” Revised Geneva (RGS) or Wells’ scores on the exclusion rate, frequency and size of missed PE and missed pneumonia. Methods Patients evaluated for suspected PE with 64-channel CTPA were prospectively enrolled from EDs and inpatient units of four hospitals. Pretest probability data were collected in real time and the D-dimer was measured in a central laboratory. Criterion standard was CPTA interpretation by two independent radiologists combined with clinical outcome at 30 days. Results Of 678 patients enrolled, 126 (19%) were PE+ and 93 (14%) had pneumonia. Use of either Wells≤4 or RGS≤6 produced similar results. For example, with RGS≤6 and standard threshold (<500 ng/mL), D-dimer was negative in 110/678 (16%), and 4/110 were PE+ (posterior probability 3.8%), and 9/110 (8.2%) had pneumonia. With RGS≤6 and a threshold <1000 ng/mL, D-dimer was negative in 208/678 (31%) and 11/208 (5.3%) were PE+, but 10/11 missed PEs were subsegmental, and none had concomitant DVT. Pneumonia was found in 12/208 (5.4%) with RGS≤6 and D-dimer<1000 ng/mL. Conclusions Doubling the threshold for a positive D-dimer with a PE unlikely pretest probability could reduce CTPA scanning with a slightly increased risk of missed isolated subsegmental PE, and no increase in rate of missed pneumonia. PMID:22284935

  14. Using Computerized Clinical Nursing Data Bases for Nursing Research.

    ERIC Educational Resources Information Center

    Nail, Lillian M.; Lange, Linda L.

    1996-01-01

    Addresses the recognition of differences between clinical and research data in using computerized clinical nursing databases and the issues of privacy and confidentiality for patients whose records are involved. Describes procedures for assessing the quality and usability of these data for nursing research. (SK)

  15. Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement.

    PubMed

    Satriano, Alessandro; Guenther, Zachary; White, James A; Merchant, Naeem; Di Martino, Elena S; Al-Qoofi, Faisal; Lydell, Carmen P; Fine, Nowell M

    2018-05-02

    Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm 2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (p<0.001 for all). 3D PSSA was independently associated with AVA by multivariable modelling. Coefficients of variation for intra- and inter-observer variability were 5.8 and 7.2%, respectively. Three-dimensional aortic PPSA analysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.

  16. Impact of implementing electronic clinical practice guidelines for the diagnosis, control and treatment of cardiovascular risk factors: A pre-post controlled study.

    PubMed

    Comin, Eva; Catalan-Ramos, Arantxa; Iglesias-Rodal, Manuel; Grau, Maria; Del Val, Jose Luis; Consola, Alicia; Amado, Ester; Pons, Angels; Mata-Cases, Manel; Franzi, Alicia; Ciurana, Ramon; Frigola, Eva; Cos, Xavier; Davins, Josep; Verdu-Rotellar, Jose M

    To evaluate the impact of computerized clinical practice guidelines on the management, diagnosis, treatment, control, and follow-up of the main cardiovascular risk factors: hypertension, hypercholesterolaemia, and type 2 diabetes mellitus. Pre-post controlled study. Catalonia, autonomous community located in north-eastern Spain. Individuals aged 35-74 years assigned to general practitioners of the Catalan Health Institute. The intervention group consisted of individuals whose general practitioners had accessed the computerized clinical practice guidelines at least twice a day, while the control group consisted of individuals whose general practitioner had never accessed the computerized clinical practice guidelines platform. The Chi-squared test was used to detect significant differences in the follow-up, control, and treatment variables for all three disorders (hypertension, hypercholesterolaemia, and type 2 diabetes mellitus) between individuals assigned to users and non-users of the computerized clinical practice guidelines, respectively. A total of 189,067 patients were included in this study, with a mean age of 56 years (standard deviation 12), and 55.5% of whom were women. Significant differences were observed in hypertension management, treatment and control; type 2 diabetes mellitus management, treatment and diagnoses, and the management and control of hypercholesterolaemia in both sexes. Computerized clinical practice guidelines are an effective tool for the control and follow-up of patients diagnosed with hypertension, type 2 diabetes mellitus, and hypercholesterolaemia. The usefulness of computerized clinical practice guidelines to diagnose and adequately treat individuals with these disorders remains unclear. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  17. Right Cardiac Chambers Involvement by a Malignant Testicular Germ Cell Tumor: An Imaging-pathologic Correlation.

    PubMed

    do Nascimento, Felipe Barjud Pereira; Albieri, Lilian; Bento Dos Santos, Glaucia Aparecida; Dolhnikoff, Marisa

    2016-07-01

    The cardiac chamber's involvement with neoplastic embolism has been rarely reported; it is mostly associated with gastric, breast, lung, liver, and prostate cancers, and usually affects the pulmonary arteries. This paper reports a case of a 31-year-old man with a malignant testicular germ cell tumor who presented with multiple episodes of pulmonary thromboembolism and died of sudden respiratory failure 1 year after the initial diagnosis. Death was attributed to massive pulmonary embolism and pulmonary infarction associated with a neoplastic thrombus that extended from the gonadal veins to pulmonary arteries. A postmortem computerized tomographic angiography and autopsy confirmed this finding. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. New developments in clinical CARS

    NASA Astrophysics Data System (ADS)

    Weinigel, Martin; Breunig, Hans Georg; Kellner-Höfer, Marcel; Bückle, Rainer; Darvin, Maxim; Lademann, Juergen; König, Karsten

    2013-02-01

    We combined two-photon fluorescence and coherent anti-Stokes Raman scattering (CARS) imaging in a clinical hybrid multiphoton tomograph for in vivo imaging of human skin. The clinically approved TPEF/CARS system provides simultaneous imaging of endogenous fluorophores and non-fluorescent lipids. The Stokes laser for the two-beam configuration of CARS is based on spectral broadening of femtosecond laser pulses in a photonic crystal fiber (PCF). We report on the highly flexible medical TPEF/CARS tomograph MPTflex®-CARS with an articulated arm and first in vivo measurements on human skin.

  19. Incentives and Barriers That Influence Clinical Computerization in Hong Kong: A Population-based Physician Survey

    PubMed Central

    Leung, Gabriel M.; Yu, Philip L. H.; Wong, Irene O. L.; Johnston, Janice M.; Tin, Keith Y. K.

    2003-01-01

    Objective: Given the slow adoption of medical informatics in Hong Kong and Asia, we sought to understand the contributory barriers and potential incentives associated with information technology implementation. Design and Measurements: A representative sample of 949 doctors (response rate = 77.0%) was asked through a postal survey to rank a list of nine barriers associated with clinical computerization according to self-perceived importance. They ranked seven incentives or catalysts that may influence computerization. We generated mean rank scores and used multidimensional preference analysis to explore key explanatory dimensions of these variables. A hierarchical cluster analysis was performed to identify homogenous subgroups of respondents. We further determined the relationships between the sets of barriers and incentives/catalysts collectively using canonical correlation. Results: Time costs, lack of technical support and large capital investments were the biggest barriers to computerization, whereas improved office efficiency and better-quality care were ranked highest as potential incentives to computerize. Cost vs. noncost, physician-related vs. patient-related, and monetary vs. nonmonetary factors were the key dimensions explaining the barrier variables. Similarly, within-practice vs external and “push” vs “pull” factors accounted for the incentive variables. Four clusters were identified for barriers and three for incentives/catalysts. Canonical correlation revealed that respondents who were concerned with the costs of computerization also perceived financial incentives and government regulation to be important incentives/catalysts toward computerization. Those who found the potential interference with communication important also believed that the promise of improved care from computerization to be a significant incentive. Conclusion: This study provided evidence regarding common barriers associated with clinical computerization. Our findings also identified possible incentive strategies that may be employed to accelerate uptake of computer systems. PMID:12595409

  20. Business aspects of cardiovascular computed tomography: tackling the challenges.

    PubMed

    Bateman, Timothy M

    2008-01-01

    The purpose of this article is to provide a comprehensive understanding of the business issues surrounding provision of dedicated cardiovascular computed tomographic imaging. Some of the challenges include high up-front costs, current low utilization relative to scanner capability, and inadequate payments. Cardiovascular computed tomographic imaging is a valuable clinical modality that should be offered by cardiovascular centers-of-excellence. With careful consideration of the business aspects, moderate-to-large size cardiology programs should be able to implement an economically viable cardiovascular computed tomographic service.

  1. Management of seizures in the elderly: a survey of UK geriatricians.

    PubMed Central

    Stolarek, I H; Brodie, A F; Brodie, M J

    1995-01-01

    The incidence and prevalence of epilepsy increase substantially with old age. Despite this, the investigation and management of this patient population remains a grey area. Four hundred and eleven (53%) consultant geriatricians responded to a questionnaire exploring their approach to seizures in the elderly in order to establish an overview of current clinical practice. Between one and five patients presenting with seizures, predominantly aged between 75-85 years, were reviewed monthly. Seventy per cent of geriatricians undertook to investigate the patients themselves with biochemical and haematological profiles performed by most. Electroencephalography and computerized tomographic scanning were routinely requested by a quarter of responders. Only 58% would themselves initiate therapy with antiepileptic drugs, with 16% of consultants starting treatment following the first seizure, 59% after a second and 5% after a third. Phenytoin was first choice for generalized tonic-clonic seizures with carbamazepine preferred for partial seizures. If good control was not obtained, 67% would substitute another first line drug, while 27% would add in a second. Less than 3% would use the new anticonvulsants lamotrigine or vigabatrin. Sixty per cent monitored anticonvulsant concentrations in patients with poor control or suspected toxicity. A wide variability was seen in the current approach to seizures in the elderly, which reflects a lack of established practice. Epilepsy clinics for the elderly would encourage structured research into the many unanswered questions affecting the care of older people with seizures. PMID:8786590

  2. [Hepatic fine needle aspiration biopsy. Experience in the study of hepatic masses at the Salvador Zubiran National Institute of Nutrition].

    PubMed

    Angeles-Angeles, A; Gamboa-Domínguez, A; Velázquez Fernández, D; Muñoz-Fernández, L

    1994-01-01

    The results of 114 fine-needle aspiration biopsies (FNAB) of the liver performed during six years (1987-1992) at the Departament of Pathology of the Instituto Nacional de la Nutrición Salvador Zubirán are presented. All were done by radiologists under ultrasonographic (three cases) or computerized tomographic guidance (111 cases). In order to determine the diagnostic accuracy, diagnoses made by FNAB were compared with those made by histological examination (coarse biopsies or surgical specimens) and/or by other diagnostic procedures including the clinical follow-up. Six cases were excluded because clinical information was not available. In 92 cases (85.2%) a correct diagnosis was made, in six (5.5%) the sample was inadequate and in 10 (9.3%) the diagnosis made by FNAB was incorrect. The diagnoses made were as follows: hepatocarcinoma 44, metastatic carcinoma 27, inflammatory lesions 12, regeneration 10, normal eight, unclassified carcinoma five, and lymphoma two. The sensitivity was 96.2, specificity 93.1, positive predictive value 97.4, negative predictive value 90.0, accuracy 95.3 and prevalence 73.1. There were three false negative and two false positive for carcinoma. These figures are similar to those found by other authors. No relevant complications were observed. It is concluded that FNAB of the liver is a safe, inexpensive and reliable method in the diagnoses of liver masses.

  3. Computerized tomographic findings of hepatic fascioliasis compared with melioidosis-caused liver abscesses.

    PubMed

    Chamadol, Nittaya; Laopaiboon, Vallop; Techasatian, Pennapa; Sukeepaisanjaroen, Wattana; Sripanuskul, Anan

    2010-07-01

    To compare the computerized tomographic (CT) findings of hepatic fascioliasis (HF) vs. melioidosis-caused liver (ML) abscesses. CT images of 15 patients with hepatic fascioliasis (HF) and 16 patients with melioidosis-caused liver (ML) abscesses were retrospectively reviewed. The authors evaluated and compared HF and ML abscesses (by chi2 and Fisher exact tests) vis-a-vis their location of liver involvement, size, shape, number margins, enhancement patterns, subcapsular lesions, internal architecture, dilatation of intrahepatic bile duct and combination with splenic abscesses. Fourteen HF patients had only liver abscesses and 1 had combined liver and splenic abscesses. Four ML patients had liver abscesses alone while 12 had combined liver and splenic abscesses (p = 0.000). Eight of the 15 HF (53.3%) and 2 of the 16 ML (12.5%) patients had subcapsular lesions (p = 0.019). The liver abscesses were round or oval with linear tracts in 8 of the 15 HF (53.3%) and none of the ML patients (p = 0.001). Between the respective HF and ML patients, there was a significant difference in those with round shaped in ML (p = 0.008), multiple and conglomerately distributed in HF (p = 0.050), multiple and discretely distributed in ML (p = 0.001) no (or minimal) peripheral contrast enhancement in HF (p = 0.011) and moderate or mark peripheral enhancement in ML (p = 0.011). The CT findings of liver abscesses that helped to differentiate hepatic fascioliasis from melioidosis liver abscesses were: their number shape, enhancement pattern, presence of subcapsular lesion (s) and co-occurrence with splenic abscesses. The diagnosis of hepatic fascioliasis by CT is suggested when the following characteristics were seen: (1) multiple, small round or oval (with linear tracts) conglomerates presenting as hypodense lesions; (2) no (or minimal) peripheral contrast enhancement; (3) subcapsular lesions; or (4) less frequent co-occurrence with splenic abscesses.

  4. Diagnostic criteria and follow-up in neuroendocrine cell hyperplasia of infancy: a case series*

    PubMed Central

    Gomes, Vivianne Calheiros Chaves; Silva, Mara Cristina Coelho; Maia, José Holanda; Daltro, Pedro; Ramos, Simone Gusmão; Brody, Alan S.; Marchiori, Edson

    2013-01-01

    OBJECTIVE: Neuroendocrine cell hyperplasia of infancy (NEHI) is a form of childhood interstitial lung disease characterized by tachypnea, retractions, crackles, and hypoxia. The aim of this study was to report and discuss the clinical, imaging, and histopathological findings in a series of NEHI cases at a tertiary pediatric hospital, with an emphasis on diagnostic criteria and clinical outcomes. METHODS: Between 2003 and 2011, 12 full-term infants were diagnosed with NEHI, based on clinical and tomographic findings. Those infants were followed for 1-91 months. Four infants were biopsied, and the histopathological specimens were stained with bombesin antibody. RESULTS: In this case series, symptoms appeared at birth in 6 infants and by 3 months of age in the remaining 6. In all of the cases, NEHI was associated with acute respiratory infection. The most common initial chest HRCT findings were ground-glass opacities that were in the middle lobe/lingula in 12 patients and in other medullary areas in 10. Air trapping was the second most common finding, being observed in 7 patients. Follow-up HRCT scans (performed in 10 patients) revealed normal results in 1 patient and improvement in 9. The biopsy findings were nonspecific, and the staining was positive for bombesin in all samples. Confirmation of NEHI was primarily based on clinical and tomographic findings. Symptoms improved during the follow-up period (mean, 41 months). A clinical cure was achieved in 4 patients. CONCLUSIONS: In this sample of patients, the diagnosis of NEHI was made on the basis of the clinical and tomographic findings, independent of the lung biopsy results. Most of the patients showed clinical improvement and persistent tomographic changes during the follow-up period, regardless of the initial severity of the disease or type of treatment. PMID:24310630

  5. Successful Transarterial Embolization of a Posttraumatic Fistula Between a Posterior Communicating Artery Aneurysm and the Cavernous Sinus: A Case Report.

    PubMed

    Jinbo, Yin; Jun, Liu; Kejie, Mou; Zheng, Zhou

    2015-01-01

    Posterior communicating artery (PCoA) aneurysm-cavernous sinus fistulae are an extremely rare complication of head injury . The treatment of PCoA aneurysm-cavernous sinus fistulae has not been well described. A 27-year-old man was admitted with a retroocular bruit and blurred vision of the left eye seven months after a severe head injury. We report the angiographic appearance of a posterior communicating artery (PCoA) aneurysm with a fistula to the cavernous sinus. This injury had been previously misinterpreted to be a PCoA aneurysm by computerized tomographic angiography (CTA). The patient was successfully treated with coils and Onyx of a fistula between the PCoA aneurysm and cavernous sinus.

  6. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    PubMed

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  7. Clinical applications with the HIDAC positron camera

    NASA Astrophysics Data System (ADS)

    Frey, P.; Schaller, G.; Christin, A.; Townsend, D.; Tochon-Danguy, H.; Wensveen, M.; Donath, A.

    1988-06-01

    A high density avalanche chamber (HIDAC) positron camera has been used for positron emission tomographic (PET) imaging in three different human studies, including patients presenting with: (I) thyroid diseases (124 cases); (II) clinically suspected malignant tumours of the pharynx or larynx (ENT) region (23 cases); and (III) clinically suspected primary malignant and metastatic tumours of the liver (9 cases, 19 PET scans). The positron emitting radiopharmaceuticals used for the three studies were Na 124I (4.2 d half-life) for the thyroid, 55Co-bleomycin (17.5 h half-life) for the ENT-region and 68Ga-colloid (68 min half-life) for the liver. Tomographic imaging was performed: (I) 24 h after oral Na 124I administration to the thyroid patients, (II) 18 h after intraveneous administration of 55Co-bleomycin to the ENT patients and (III) 20 min following the intraveneous injection of 68Ga-colloid to the liver tumour patients. Three different imaging protocols were used with the HIDAC positron camera to perform appropriate tomographic imaging in each patient study. Promising results were obtained in all three studies, particularly in tomographic thyroid imaging, where a significant clinical contribution is made possible for diagnosis and therapy planning by the PET technique. In the other two PET studies encouraging results were obtained for the detection and precise localisation of malignant tumour disease including an estimate of the functional liver volume based on the reticulo-endothelial-system (RES) of the liver, obtained in vivo, and the three-dimensional display of liver PET data using shaded graphics techniques. The clinical significance of the overall results obtained in both the ENT and the liver PET study, however, is still uncertain and the respective role of PET as a new imaging modality in these applications is not yet clearly established. To appreciate the clinical impact made by PET in liver and ENT malignant tumour staging needs further investigation, and more detailed data on a larger number of clinical and experimental PET scans will be necessary for definitive evaluation. Nevertheless, the HIDAC positron camera may be used for clinical PET imaging in well-defined patient cases, particularly in situations where both high spatial resolution is desired in the reconstructed image of the examined pathological condition and at the same time "static" PET imaging may be adequate, as is the case in thyroid-, ENT- and liver tomographic imaging using the HIDAC positron camera.

  8. A computerized tomography system for transcranial ultrasound imaging.

    PubMed

    Tang, Sai Chun; Clement, Gregory T

    Hardware for tomographic imaging presents both challenge and opportunity for simplification when compared with traditional pulse-echo imaging systems. Specifically, point diffraction tomography does not require simultaneous powering of elements, in theory allowing just a single transmit channel and a single receive channel to be coupled with a switching or multiplexing network. In our ongoing work on transcranial imaging, we have developed a 512-channel system designed to transmit and/or receive a high voltage signal from/to arbitrary elements of an imaging array. The overall design follows a hierarchy of modules including a software interface, microcontroller, pulse generator, pulse amplifier, high-voltage power converter, switching mother board, switching daughter board, receiver amplifier, analog-to-digital converter, peak detector, memory, and USB communication. Two pulse amplifiers are included, each capable of producing up to 400Vpp via power MOSFETS. Switching is based around mechanical relays that allow passage of 200V, while still achieving switching times of under 2ms, with an operating frequency ranging from below 100kHz to 10MHz. The system is demonstrated through ex vivo human skulls using 1MHz transducers. The overall system design is applicable to planned human studies in transcranial image acquisition, and may have additional tomographic applications for other materials necessitating a high signal output.

  9. Multi-dimensional distribution of near-field ionospheric disturbances produced by the 2015 Mw7.8 Nepal earthquake

    NASA Astrophysics Data System (ADS)

    Tang, Jun; Yuan, Yunbin

    2017-10-01

    Ionospheric anomalies possibly associated with large earthquakes, particularly coseismic ionospheric disturbances, have been detected by global positioning system (GPS). A large Nepal earthquake with magnitude Mw7.8 occurred on April 25, 2015. In this paper, we investigate the multi-dimensional distribution of near-field coseismic ionospheric disturbances (CIDs) using total electron content (TEC) and computerized ionospheric tomography (CIT) from regional GPS observational data. The results show significant ionospheric TEC disturbances and interesting multi-dimensional structures around the main shock. Regarding the TEC changes, coseismic ionospheric disturbances occur approximately 10-20 min after the earthquake northeast and northwest of epicentre. The maximum ridge-to-trough amplitude of CIDs is up to approximately 0.90 TECU/min. Propagation velocities of the TEC disturbances are 1.27 ± 0.06 km/s and 1.91 ± 0.38 km/s. It is believed that the ionospheric disturbances are triggered by acoustic and Rayleigh waves. Tomographic results show that the three-dimensional distribution of ionospheric disturbances obviously increases at an altitude of 300 km above the surrounding epicentre, predominantly in the entire region between 200 km and 400 km. Significant ionospheric disturbances appear at 06:30 UT from tomographic images. This study reveals characteristics of an ionospheric anomaly caused by the Nepal earthquake.

  10. Evaluating the Effectiveness of Nurse-Focused Computerized Clinical Decision Support on Urinary Catheter Practice Guidelines

    ERIC Educational Resources Information Center

    Lang, Robin Lynn Neal

    2012-01-01

    A growing national emphasis has been placed on health information technology (HIT) with robust computerized clinical decision support (CCDS) integration into health care delivery. Catheter-associated urinary tract infection is the most frequent health care-associated infection in the United States and is associated with high cost, high volumes and…

  11. The Child Well-Being Scales as a Clinical Tool and a Management Information System.

    ERIC Educational Resources Information Center

    Lyons, Peter; Doueck, Howard J.; Koster, Andrew J.; Witzky, Melissa K.; Kelly, Patricia L.

    1999-01-01

    Describes implementation of a computerized version of the Child Welfare League of America's Child Well-Being Scales by a family services agency in southern Ontario. Reviews results obtained from 172 families to illustrate the potential for using computerized risk assessment as an aid in clinical, supervisory, and management decision-making…

  12. Improving Emergency Department Triage Classification with Computerized Clinical Decision Support at a Pediatric Hospital

    ERIC Educational Resources Information Center

    Kunisch, Joseph Martin

    2012-01-01

    Background: The Emergency Severity Index (ESI) is an emergency department (ED) triage classification system based on estimated patient-specific resource utilization. Rules for a computerized clinical decision support (CDS) system based on a patient's chief complaint were developed and tested using a stochastic model for predicting ESI scores.…

  13. Commentary: the postdoctoral residency match in clinical neuropsychology.

    PubMed

    Bodin, Doug; Grote, Christopher L

    2016-07-01

    Postdoctoral recruitment in clinical neuropsychology has evolved significantly over the past two decades. Prior to 1994, there were no organized recruitment guidelines for the specialty. From 1994 to 2001, the Association of Postdoctoral Programs in Clinical Neuropsychology (APPCN) facilitated a uniform notification date where member programs agreed to not make offers prior to a specified date. In 2001, APPCN partnered with National Matching Services to administer a computerized match recruitment system. Presently, not all programs participate in the match. This often results in students applying to 'match' and 'non-match' programs which can lead to significant stress on the part of applicants and program directors. This issue has recently become the focus of journal articles and public discussions. The goals of this paper were to review the history of postdoctoral recruitment in clinical neuropsychology, review the benefits of coordinated recruitment systems, review the structure and function of the computerized match, and explain why the computerized match for postdoctoral recruitment in clinical neuropsychology is beneficial for the specialty of clinical neuropsychology.

  14. Herpes simplex encephalitis (HSE) and the immunocompromised: a clinical and autopsy study of HSE in the settings of cancer and human immunodeficiency virus-type 1 infection.

    PubMed

    Schiff, D; Rosenblum, M K

    1998-03-01

    Although herpes simplex encephalitis (HSE) is not regarded as an opportunistic infection, the occurrence of HSE in immunocompromised patients has been documented and the suggestion made that unusual clinical and neuropathologic features characterize the disorder in this population. To further characterize HSE as it affects the immunodeficient, the authors reviewed the clinical and pathological findings in three immunocompromised patients with autopsy-proven HSE. Two patients had cancer (one with lymphoma and another with glioblastoma multiforme), one was known to be human immunodeficiency virus-type 1 (HIV-1)-seropositive and a second was suspected of harboring underlying HIV-1 infection. Two were receiving dexamethasone at onset of HSE. All had fever, mental status changes and new, focal neurological deficits or worsening of established deficits. Cerebrospinal fluid (CSF) pleocytosis was absent or minimal and head computerized tomographic (CT) scans, performed in all cases, were unrevealing. No patient was clinically suspected of having HSE, only one received acyclovir (for concurrent mucocutaneous herpes) and HSE played a major role in all deaths. Autopsy revealed an unusual form of HSE characterized by a noninflammatory, pseudoischemic histological presentation and the unexpected persistence of viral antigens in abundance despite survival beyond the clinical stage during which inflammatory responses usually peak and productive brain infection wanes. The incidence of HSE in the immunocompromised may be underestimated. Preexistent neurological disease, a noninflammatory CSF profile and negative CT scan may confound the diagnosis in this population, a typical clinical presentation notwithstanding. Increased clinical suspicion, the use of magnetic resonance imaging and polymerase chain reaction analysis of CSF for herpes simplex virus nucleic acid sequences may permit more rapid diagnosis and treatment. The absence of inflammatory infiltrates in some fatal cases of HSE suggests that an intact immune response is not requisite to the devastating neurological injury characteristic of this disorder.

  15. Computerized symptom and quality-of-life assessment for patients with cancer part II: acceptability and usability.

    PubMed

    Mullen, Kristin H; Berry, Donna L; Zierler, Brenda K

    2004-09-01

    To determine the acceptability and usability of a computerized quality-of-life (QOL) and symptom assessment tool and the graphically displayed QOL and symptom output in an ambulatory radiation oncology clinic. Descriptive, cross-sectional. Radiation oncology clinic located in an urban university medical center. 45 patients with cancer being evaluated for radiation therapy and 10 clinicians, who submitted 12 surveys. Acceptability of the computerized assessment was measured with an online, 16-item, Likert-style survey delivered as 45 patients undergoing radiation therapy completed a 25-item QOL and symptom assessment. Usability of the graphic output was assessed with clinician completion of a four-item paper survey. Acceptability and usability of computerized patient assessment. The patient acceptability survey indicated that 70% (n = 28) liked computers and 10% (n = 4) did not. The program was easy to use for 79% (n = 26), easy to understand for 91% (n = 30), and enjoyable for 71% (n = 24). Seventy-six percent (n = 25) believed that the amount of time needed to complete the computerized survey was acceptable. Sixty-six percent (n = 21) responded that they were satisfied with the program, and none of the participants chose the very dissatisfied response. Eighty-three percent (n = 10) of the clinicians found the graphic output helpful in promoting communication with patients, 75% (n = 9) found the output report helpful in identifying appropriate areas of QOL deficits or concerns, and 83% (n = 10) indicated that the output helped guide clinical interactions with patients. The computer-based QOL and symptom assessment tool is acceptable to patients, and the graphically displayed QOL and symptom output is useful to radiation oncology nurses and physicians. Wider application of computerized patient-generated data can continue in various cancer settings and be tested for clinical and organizational outcomes.

  16. What can paper-based clinical information systems tell us about the design of computerized clinical information systems (CIS) in the ICU?

    PubMed

    Miller, A; Pilcher, D; Mercaldo, N; Leong, T; Scheinkestel, C; Schildcrout, J

    2010-08-01

    Screen designs in computerized clinical information systems (CIS) have been modeled on their paper predecessors. However, limited understanding about how paper forms support clinical work means that we risk repeating old mistakes and creating new opportunities for error and inefficiency as illustrated by problems associated with computerized provider order entry systems. This study was designed to elucidate principles underlying a successful ICU paper-based CIS. The research was guided by two exploratory hypotheses: (1) paper-based artefacts (charts, notes, equipment, order forms) are used differently by nurses, doctors and other healthcare professionals in different (formal and informal) conversation contexts and (2) different artefacts support different decision processes that are distributed across role-based conversations. All conversations undertaken at the bedsides of five patients were recorded with any supporting artefacts for five days per patient. Data was coded according to conversational role-holders, clinical decision process, conversational context and artefacts. 2133 data points were analyzed using Poisson logistic regression analyses. Results show significant interactions between artefacts used during different professional conversations in different contexts (chi(2)((df=16))=55.8, p<0.0001). The interaction between artefacts used during different professional conversations for different clinical decision processes was not statistically significant although all two-way interactions were statistically significant. Paper-based CIS have evolved to support complex interdisciplinary decision processes. The translation of two design principles - support interdisciplinary perspectives and integrate decision processes - from paper to computerized CIS may minimize the risks associated with computerization. 2010 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.

  17. Comparison study on the feasibility of photoacoustic power spectrum analysis in osteoporosis detection

    NASA Astrophysics Data System (ADS)

    He, Weizhen; Zhu, Yunhao; Feng, Ting; Wang, Huaideng; Yuan, Jie; Xu, Guan; Wang, Xueding; Carson, Paul

    2017-03-01

    Osteoporosis is a progressive bone disease which is characterized by a decrease in the bone mass and deterioration in bone micro-architecture. In theory, photoacoustic (PA) imaging analysis has potential to obtain the characteristics of the bone effectively. Previous study demonstrated that photoacoustic spectral analysis (PASA) method with the qualified parameter slope could provide an objective assessment of bone microstructure and deterioration. In this study, we tried to compare PASA method with the traditional quantitative ultrasound (QUS) method in osteoporosis assessment. Numerical simulations of both PA and ultrasound (US) signal are performed on computerized tomographic (CT) images of trabecular bone with different bone mineral densities (BMDs). Ex vivo experiments were conducted on porcine femur bone model of different BMDs. We compared the quantified parameter slope and the broadband ultrasound attenuation (BUA) coefficient from the PASA and QUS among different bone models, respectively. Both the simulation and ex vivo experiment results show that bone with low BMD has a higher slope value and lower BUA value. Our result demonstrated that the PASA method has the same efficacy with QUS in bone assessment, considering PA is a non-ionizing, non-invasive technique, PASA method holds potential for clinical diagnosis in osteoporosis and other bone diseases.

  18. Identifying design considerations for a shared decision aid for use at the point of outpatient clinical care: An ethnographic study at an inner city clinic.

    PubMed

    Hajizadeh, Negin; Perez Figueroa, Rafael E; Uhler, Lauren M; Chiou, Erin; Perchonok, Jennifer E; Montague, Enid

    2013-03-06

    Computerized decision aids could facilitate shared decision-making at the point of outpatient clinical care. The objective of this study was to investigate whether a computerized shared decision aid would be feasible to implement in an inner-city clinic by evaluating the current practices in shared decision-making, clinicians' use of computers, patient and clinicians' attitudes and beliefs toward computerized decision aids, and the influence of time on shared decision-making. Qualitative data analysis of observations and semi-structured interviews with patients and clinicians at an inner-city outpatient clinic. The findings provided an exploratory look at the prevalence of shared decision-making and attitudes about health information technology and decision aids. A prominent barrier to clinicians engaging in shared decision-making was a lack of perceived patient understanding of medical information. Some patients preferred their clinicians make recommendations for them rather than engage in formal shared decision-making. Health information technology was an integral part of the clinic visit and welcomed by most clinicians and patients. Some patients expressed the desire to engage with health information technology such as viewing their medical information on the computer screen with their clinicians. All participants were receptive to the idea of a decision aid integrated within the clinic visit although some clinicians were concerned about the accuracy of prognostic estimates for complex medical problems. We identified several important considerations for the design and implementation of a computerized decision aid including opportunities to: bridge clinician-patient communication about medical information while taking into account individual patients' decision-making preferences, complement expert clinician judgment with prognostic estimates, take advantage of patient waiting times, and make tasks involved during the clinic visit more efficient. These findings should be incorporated into the design and implementation of a computerized shared decision aid at an inner-city hospital.

  19. An Integrated Computerized Triage System in the Emergency Department

    PubMed Central

    Aronsky, Dominik; Jones, Ian; Raines, Bill; Hemphill, Robin; Mayberry, Scott R; Luther, Melissa A; Slusser, Ted

    2008-01-01

    Emergency department (ED) triage is a fast-paced process that prioritizes the allocation of limited health care resources to patients in greatest need. This paper describes the experiences with an integrated, computerized triage application. The system exchanges information with other information systems, including the ED patient tracking board, the longitudinal electronic medical record, the computerized provider order entry, and the medication reconciliation application. The application includes decision support capabilities such as assessing the patient’s acuity level, age-dependent alerts for vital signs, and clinical reminders. The browser-based system utilizes the institution’s controlled vocabulary, improves data completeness and quality, such as compliance with capturing required data elements and screening questions, initiates clinical processes, such as pneumococcal vaccination ordering, and reminders to start clinical pathways, issues alerts for clinical trial eligibility, and facilitates various reporting needs. The system has supported the triage documentation of >290,000 pediatric and adult patients. PMID:18999190

  20. Reaching out to clinicians: implementation of a computerized alert system.

    PubMed

    Degnan, Dan; Merryfield, Dave; Hultgren, Steve

    2004-01-01

    Several published articles have identified that providing automated, computer-generated clinical alerts about potentially critical clinical situations should result in better quality of care. In 1999, the pharmacy department at a community hospital network implemented and refined a commercially available, computerized clinical alert system. This case report discusses the implementation process, gives examples of how the system is used, and describes results following implementation. The use of the clinical alert system in this hospital network resulted in improved patient safety as well as in greater efficiency and decreased costs.

  1. Improving perceptions of empathy in patients undergoing low-yield computerized tomographic imaging in the emergency department.

    PubMed

    Lin, Michelle P; Probst, Marc A; Puskarich, Michael A; Dehon, Erin; Kuehl, Damon R; Wang, Ralph C; Hess, Erik P; Butler, Katie; Runyon, Michael S; Wang, Hao; Courtney, D Mark; Muckley, Brandon; Hobgood, Cherri D; Hall, Cassandra L; Kline, Jeffrey A

    2018-04-01

    We assessed emergency department (ED) patient perceptions of how physicians can improve their language to determine patient preferences for 11 phrases to enhance physician empathy toward the goal of reducing low-value advanced imaging. Multi-center survey study of low-risk ED patients undergoing computerized tomography (CT) scanning. We enroled 305 participants across nine sites. The statement "I have carefully considered what you told me about what brought you here today" was most frequently rated as important (88%). The statement "I have thought about the cost of your medical care to you today" was least frequently rated as important (59%). Participants preferred statements indicating physicians had considered their "vital signs and physical examination" (86%), "past medical history" (84%), and "what prior research tells me about your condition" (79%). Participants also valued statements conveying risks of testing, including potential kidney injury (78%) and radiation (77%). The majority of phrases were identified as important. Participants preferred statements conveying cognitive reassurance, medical knowledge and risks of testing. Our findings suggest specific phrases have the potential to enhance ED patient perceptions of physician empathy. Further research is needed to determine whether statements to convey empathy affect diagnostic testing rates. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Use of Noncontrast Computed Tomography and Computed Tomographic Perfusion in Predicting Intracerebral Hemorrhage After Intravenous Alteplase Therapy.

    PubMed

    Batchelor, Connor; Pordeli, Pooneh; d'Esterre, Christopher D; Najm, Mohamed; Al-Ajlan, Fahad S; Boesen, Mari E; McDougall, Connor; Hur, Lisa; Fainardi, Enrico; Shankar, Jai Jai Shiva; Rubiera, Marta; Khaw, Alexander V; Hill, Michael D; Demchuk, Andrew M; Sajobi, Tolulope T; Goyal, Mayank; Lee, Ting-Yim; Aviv, Richard I; Menon, Bijoy K

    2017-06-01

    Intracerebral hemorrhage is a feared complication of intravenous alteplase therapy in patients with acute ischemic stroke. We explore the use of multimodal computed tomography in predicting this complication. All patients were administered intravenous alteplase with/without intra-arterial therapy. An age- and sex-matched case-control design with classic and conditional logistic regression techniques was chosen for analyses. Outcome was parenchymal hemorrhage on 24- to 48-hour imaging. Exposure variables were imaging (noncontrast computed tomography hypoattenuation degree, relative volume of very low cerebral blood volume, relative volume of cerebral blood flow ≤7 mL/min·per 100 g, relative volume of T max ≥16 s with all volumes standardized to z axis coverage, mean permeability surface area product values within T max ≥8 s volume, and mean permeability surface area product values within ipsilesional hemisphere) and clinical variables (NIHSS [National Institutes of Health Stroke Scale], onset to imaging time, baseline systolic blood pressure, blood glucose, serum creatinine, treatment type, and reperfusion status). One-hundred eighteen subjects (22 patients with parenchymal hemorrhage versus 96 without, median baseline NIHSS score of 15) were included in the final analysis. In multivariable regression, noncontrast computed tomography hypoattenuation grade ( P <0.006) and computerized tomography perfusion white matter relative volume of very low cerebral blood volume ( P =0.04) were the only significant variables associated with parenchymal hemorrhage on follow-up imaging (area under the curve, 0.73; 95% confidence interval, 0.63-0.83). Interrater reliability for noncontrast computed tomography hypoattenuation grade was moderate (κ=0.6). Baseline hypoattenuation on noncontrast computed tomography and very low cerebral blood volume on computerized tomography perfusion are associated with development of parenchymal hemorrhage in patients with acute ischemic stroke receiving intravenous alteplase. © 2017 American Heart Association, Inc.

  3. Surface mapping of spike potential fields: experienced EEGers vs. computerized analysis.

    PubMed

    Koszer, S; Moshé, S L; Legatt, A D; Shinnar, S; Goldensohn, E S

    1996-03-01

    An EEG epileptiform spike focus recorded with scalp electrodes is clinically localized by visual estimation of the point of maximal voltage and the distribution of its surrounding voltages. We compared such estimated voltage maps, drawn by experienced electroencephalographers (EEGers), with a computerized spline interpolation technique employed in the commercially available software package FOCUS. Twenty-two spikes were recorded from 15 patients during long-term continuous EEG monitoring. Maps of voltage distribution from the 28 electrodes surrounding the points of maximum change in slope (the spike maximum) were constructed by the EEGer. The same points of maximum spike and voltage distributions at the 29 electrodes were mapped by computerized spline interpolation and a comparison between the two methods was made. The findings indicate that the computerized spline mapping techniques employed in FOCUS construct voltage maps with similar maxima and distributions as the maps created by experienced EEGers. The dynamics of spike activity, including correlations, are better visualized using the computerized technique than by manual interpretation alone. Its use as a technique for spike localization is accurate and adds information of potential clinical value.

  4. Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children

    PubMed Central

    Chakravarthy, Murali; Sunilkumar, Gubbihalli; Pargaonkar, Sumant; Hosur, Rajathadri; Harivelam, Chidananda; Kavaraganahalli, Deepak; Srinivasan, Pradeep

    2015-01-01

    Objective: The purpose of our study was to determine the effect of induced apnea on quality of cardiopulmonary structures during computerized tomographic (CT) angiography images in children with congenital heart diseases. Methods: Pediatric patients with congenital heart defects undergoing cardiac CT angiography at our facility in the past 3 years participated in this study. The earlier patients underwent cardiac CT angiography without induced apnea and while, later, apnea was induced in patients, which was followed by electrocardiogram gated cardiac CT angiography. General anesthesia was induced using sleep dose of intravenous propofol. After the initial check CT, on request by the radiologist, apnea was induced by the anesthesiologist by administering 1 mg/kg of intravenous suxamethonium. Soon after apnea ensued, the contrast was injected, and CT angiogram carried out. CT images in the “apnea group” were compared with those in “nonapnea group.” After the completion of the procedure, the patients were mask ventilated with 100% oxygen till the spontaneous ventilation was restored. Results: We studied 46 patients, of whom 36 with apnea and yet another 10 without. The quality of the image, visualization of structures such as cardiac wall, outflow tracts, lung field, aortopulmonary shunts, and coronary arteries were analyzed and subjected to statistical analysis (Mann–Whitney U, Fischer's exact test and Pearson's Chi-square test). In the induced apnea group, overall image quality was considered excellent in 89% (n = 33) of the studies, while in the “no apnea group,” only 30% of studies were excellent. Absent or minimal motion artifacts were seen in a majority of the studies in apnea group (94%). In the nonapnea group, the respiratory and body motion artifacts were severe in 50%, moderate in 30%, and minimal in 20%, but they were significantly lesser in the apnea group. All the studied parameters were statistically significant in the apnea group in contrast to nonapnea group (P < 0.000). Conclusion: The image quality of cardiac CT angiography greatly improves, and motion artifact significantly decreases with the use of induced apnea in pediatrics patients being evaluated for congenital heart disease. This technique poses no additional morbidity of significance. PMID:25849686

  5. Nephroureterectomy and ureteroneocystostomy in an alpaca with bilateral ectopic ureters diagnosed by computed tomographic excretory urography.

    PubMed

    Polf, Holly D; Smith, Shasta; Simpson, Katharine M; Rochat, Mark C

    2015-01-01

    To report diagnosis and treatment of urinary incontinence in a female Huacaya alpaca. Clinical case report. Female intact Huacaya alpaca (n = 1) METHODS: Computed tomographic (CT) excretory urography and vaginourethrography were performed to diagnose the cause of urinary incontinence. Bilateral ectopic ureters and left hydronephrosis and hydroureter were diagnosed. Left nephroureterectomy and right ureteroneocystostomy were performed with subsequent resolution of clinical signs. Pyelonephritis was identified by culture of the resected left kidney. CT excretory urography was helpful in the diagnosis of bilateral ectopic ureters in an alpaca and provided information for surgical planning. Surgical repair by ureteroneocystostomy and unilateral nephroureterectomy was successful in resolving clinical signs. © Copyright 2014 by The American College of Veterinary Surgeons.

  6. Reduced Clostridium difficile Tests and Laboratory-Identified Events With a Computerized Clinical Decision Support Tool and Financial Incentive.

    PubMed

    Madden, Gregory R; German Mesner, Ian; Cox, Heather L; Mathers, Amy J; Lyman, Jason A; Sifri, Costi D; Enfield, Kyle B

    2018-06-01

    We hypothesized that a computerized clinical decision support tool for Clostridium difficile testing would reduce unnecessary inpatient tests, resulting in fewer laboratory-identified events. Census-adjusted interrupted time-series analyses demonstrated significant reductions of 41% fewer tests and 31% fewer hospital-onset C. difficile infection laboratory-identified events following this intervention.Infect Control Hosp Epidemiol 2018;39:737-740.

  7. 5D-intravital tomography as a novel tool for non-invasive in-vivo analysis of human skin

    NASA Astrophysics Data System (ADS)

    König, Karsten; Weinigel, Martin; Breunig, Hans G.; Gregory, Axel; Fischer, Peter; Kellner-Höfer, Marcel; Bückle, Rainer; Schwarz, Martin; Riemann, Iris; Stracke, Frank; Huck, Volker; Gorzelanny, Christian; Schneider, Stefan W.

    2010-02-01

    Some years ago, CE-marked clinical multiphoton systems for 3D imaging of human skin with subcellular resolution have been launched. These tomographs provide optical biopsies with submicron resolution based on two-photon excited autofluorescence (NAD(P)H, flavoproteins, keratin, elastin, melanin, porphyrins) and second harmonic generation by collagen. The 3D tomograph was now transferred into a 5D imaging system by the additional detection of the emission spectrum and the fluorescence lifetime based on spatially and spectrally resolved time-resolved single photon counting. The novel 5D intravital tomograph (5D-IVT) was employed for the early detection of atopic dermatitis and the analysis of treatment effects.

  8. Scaled Anatomical Model Creation of Biomedical Tomographic Imaging Data and Associated Labels for Subsequent Sub-surface Laser Engraving (SSLE) of Glass Crystals.

    PubMed

    Betts, Aislinn M; McGoldrick, Matthew T; Dethlefs, Christopher R; Piotrowicz, Justin; Van Avermaete, Tony; Maki, Jeff; Gerstler, Steve; Leevy, W M

    2017-04-25

    Biomedical imaging modalities like computed tomography (CT) and magnetic resonance (MR) provide excellent platforms for collecting three-dimensional data sets of patient or specimen anatomy in clinical or preclinical settings. However, the use of a virtual, on-screen display limits the ability of these tomographic images to fully convey the anatomical information embedded within. One solution is to interface a biomedical imaging data set with 3D printing technology to generate a physical replica. Here we detail a complementary method to visualize tomographic imaging data with a hand-held model: Sub Surface Laser Engraving (SSLE) of crystal glass. SSLE offers several unique benefits including: the facile ability to include anatomical labels, as well as a scale bar; streamlined multipart assembly of complex structures in one medium; high resolution in the X, Y, and Z planes; and semi-transparent shells for visualization of internal anatomical substructures. Here we demonstrate the process of SSLE with CT data sets derived from pre-clinical and clinical sources. This protocol will serve as a powerful and inexpensive new tool with which to visualize complex anatomical structures for scientists and students in a number of educational and research settings.

  9. Computerized Drug Information Services

    ERIC Educational Resources Information Center

    And Others; Smith, Daniel R.

    1972-01-01

    To compare computerized services in chemistry, pharmacology, toxicology, and clinical medicine of pharmaceutical interest, equivalent profiles were run on magnetic tape files of CA-Condensates," CBAC," Excerpta Medica," MEDLARS" and Ringdoc." The results are tabulated for overlap of services, relative speed of citing references, and unique…

  10. Validation of diabetes mellitus and hypertension diagnosis in computerized medical records in primary health care

    PubMed Central

    2011-01-01

    Background Computerized Clinical Records, which are incorporated in primary health care practice, have great potential for research. In order to use this information, data quality and reliability must be assessed to prevent compromising the validity of the results. The aim of this study is to validate the diagnosis of hypertension and diabetes mellitus in the computerized clinical records of primary health care, taking the diagnosis criteria established in the most prominently used clinical guidelines as the gold standard against which what measure the sensitivity, specificity, and determine the predictive values. The gold standard for diabetes mellitus was the diagnostic criteria established in 2003 American Diabetes Association Consensus Statement for diabetic subjects. The gold standard for hypertension was the diagnostic criteria established in the Joint National Committee published in 2003. Methods A cross-sectional multicentre validation study of diabetes mellitus and hypertension diagnoses in computerized clinical records of primary health care was carried out. Diagnostic criteria from the most prominently clinical practice guidelines were considered for standard reference. Sensitivity, specificity, positive and negative predictive values, and global agreement (with kappa index), were calculated. Results were shown overall and stratified by sex and age groups. Results The agreement for diabetes mellitus with the reference standard as determined by the guideline was almost perfect (κ = 0.990), with a sensitivity of 99.53%, a specificity of 99.49%, a positive predictive value of 91.23% and a negative predictive value of 99.98%. Hypertension diagnosis showed substantial agreement with the reference standard as determined by the guideline (κ = 0.778), the sensitivity was 85.22%, the specificity 96.95%, the positive predictive value 85.24%, and the negative predictive value was 96.95%. Sensitivity results were worse in patients who also had diabetes and in those aged 70 years or over. Conclusions Our results substantiate the validity of using diagnoses of diabetes and hypertension found within the computerized clinical records for epidemiologic studies. PMID:22035202

  11. Reliability, validity and sensitivity of a computerized visual analog scale measuring state anxiety.

    PubMed

    Abend, Rany; Dan, Orrie; Maoz, Keren; Raz, Sivan; Bar-Haim, Yair

    2014-12-01

    Assessment of state anxiety is frequently required in clinical and research settings, but its measurement using standard multi-item inventories entails practical challenges. Such inventories are increasingly complemented by paper-and-pencil, single-item visual analog scales measuring state anxiety (VAS-A), which allow rapid assessment of current anxiety states. Computerized versions of VAS-A offer additional advantages, including facilitated and accurate data collection and analysis, and applicability to computer-based protocols. Here, we establish the psychometric properties of a computerized VAS-A. Experiment 1 assessed the reliability, convergent validity, and discriminant validity of the computerized VAS-A in a non-selected sample. Experiment 2 assessed its sensitivity to increase in state anxiety following social stress induction, in participants with high levels of social anxiety. Experiment 1 demonstrated the computerized VAS-A's test-retest reliability (r = .44, p < .001); convergent validity with the State-Trait Anxiety Inventory's state subscale (STAI-State; r = .60, p < .001); and discriminant validity as indicated by significantly lower correlations between VAS-A and different psychological measures relative to the correlation between VAS-A and STAI-State. Experiment 2 demonstrated the VAS-A's sensitivity to changes in state anxiety via a significant pre- to during-stressor rise in VAS-A scores (F(1,48) = 25.13, p < .001). Set-order administration of measures, absence of clinically-anxious population, and gender-unbalanced samples. The adequate psychometric characteristics, combined with simple and rapid administration, make the computerized VAS-A a valuable self-rating tool for state anxiety. It may prove particularly useful for clinical and research settings where multi-item inventories are less applicable, including computer-based treatment and assessment protocols. The VAS-A is freely available: http://people.socsci.tau.ac.il/mu/anxietytrauma/visual-analog-scale/. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. The effectiveness of computerized drug-lab alerts: a systematic review and meta-analysis.

    PubMed

    Bayoumi, Imaan; Al Balas, Mosab; Handler, Steven M; Dolovich, Lisa; Hutchison, Brian; Holbrook, Anne

    2014-06-01

    Inadequate lab monitoring of drugs is a potential cause of ADEs (adverse drug events) which is remediable. To determine the effectiveness of computerized drug-lab alerts to improve medication-related outcomes. Citations from the Computerized Clinical Decision Support System Systematic Review (CCDSSR) and MMIT (Medications Management through Health Information Technology) databases, which had searched MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, International Pharmaceutical Abstracts from 1974 to March 27, 2013. Randomized controlled trials (RCTs) of clinician-targeted computerized drug lab alerts conducted in any healthcare setting. Two reviewers performed full text review to determine study eligibility. A single reviewer abstracted data and evaluated validity of included studies using Cochrane handbook domains. Thirty-six studies met the inclusion criteria (25 single drug studies with 22,504 participants, 14 targeting anticoagulation; 11 multi-drug studies with 56,769 participants). ADEs were reported as an outcome in only four trials, all targeting anticoagulants. Computerized drug-lab alerts did not reduce ADEs (OR 0.89, 95% CI 0.79-1.00, p=0.05), length of hospital stay (SMD 0.00, 95%CI -0.93 to 0.93, p=0.055, 1 study), likelihood of hypoglycemia (OR 1.29, 95% CI 0.31-5.37) or likelihood of bleeding, but were associated with increased likelihood of prescribing changes (OR 1.73, 95% CI 1.21-2.47) or lab monitoring (OR 1.47, 95% confidence interval 1.12-1.94) in accordance with the alert. There is no evidence that computerized drug-lab alerts are associated with important clinical benefits, but there is evidence of improvement in selected clinical surrogate outcomes (time in therapeutic range for vitamin K antagonists), and changes in process outcomes (lab monitoring and prescribing decisions). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana).

    PubMed

    Horowitz, Seth S; Simmons, Andrea Megela; Ketten, Darlene R

    2005-08-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna (footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of the opercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation.

  14. Optical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana)

    PubMed Central

    Horowitz, Seth S.; Simmons, Andrea Megela; Ketten, Darlene R.

    2005-01-01

    Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna(footplate) of the stapes and the operculum are present in their normal positions at the entrance of the otic capsule on both the affected and unaffected sides. The pattern of deformity suggests a partial failure of development of tympanic pathway tissues, but with a preservation of theopercularis pathway. While a definitive proximate cause of the condition could not be determined, the anomalies show similarities to developmental defects in mammalian middle ear formation. PMID:16158670

  15. Tomographic reconstruction of ionospheric electron density during the storm of 5-6 August 2011 using multi-source data

    PubMed Central

    Tang, Jun; Yao, Yibin; Zhang, Liang; Kong, Jian

    2015-01-01

    The insufficiency of data is the essential reason for ill-posed problem existed in computerized ionospheric tomography (CIT) technique. Therefore, the method of integrating multi-source data is proposed. Currently, the multiple satellite navigation systems and various ionospheric observing instruments provide abundant data which can be employed to reconstruct ionospheric electron density (IED). In order to improve the vertical resolution of IED, we do research on IED reconstruction by integration of ground-based GPS data, occultation data from the LEO satellite, satellite altimetry data from Jason-1 and Jason-2 and ionosonde data. We used the CIT results to compare with incoherent scatter radar (ISR) observations, and found that the multi-source data fusion was effective and reliable to reconstruct electron density, showing its superiority than CIT with GPS data alone. PMID:26266764

  16. A rare case of ethambutol induced pulmonary eosinophilia

    PubMed Central

    Saha, Kaushik; Bandyopadhyay, Ankan; Sengupta, Amitabha; Jash, Debraj

    2013-01-01

    Antitubercular drug (ATD) induced eosinophilic lung disease is a rare phenomenon. It usually occurs due to isoniazid and para amino salicylic acid. A 34-year-male of sputum positive pulmonary tuberculosis, on antitubercular drugs (rifampicin, isoniazid, ethambutol, and pyrazinamide) for last 3 weeks, presented with generalized arthralgia and maculopapular rash for last 2 weeks and shortness of breath for last 1 week. Chest X-ray and High resolution computerized tomographic scan thorax showed bilateral peripheral airspace opacification. Bronchoalveolar lavage revealed 51% eosinophils of total cellularity (1200/cmm) confirming the diagnosis of pulmonary eosinophilia. ATD was stopped for 2 weeks and then reintroduced one by one. Patient again developed similar kind of symptoms with reintroduction of ethambutol. According to criteria for drug induced pulmonary eosinophilia, he was diagnosed as a case of ethambutol induced pulmonary eosinophilia. PMID:24250213

  17. Tomographic reconstruction of ionospheric electron density during the storm of 5-6 August 2011 using multi-source data.

    PubMed

    Tang, Jun; Yao, Yibin; Zhang, Liang; Kong, Jian

    2015-08-12

    The insufficiency of data is the essential reason for ill-posed problem existed in computerized ionospheric tomography (CIT) technique. Therefore, the method of integrating multi-source data is proposed. Currently, the multiple satellite navigation systems and various ionospheric observing instruments provide abundant data which can be employed to reconstruct ionospheric electron density (IED). In order to improve the vertical resolution of IED, we do research on IED reconstruction by integration of ground-based GPS data, occultation data from the LEO satellite, satellite altimetry data from Jason-1 and Jason-2 and ionosonde data. We used the CIT results to compare with incoherent scatter radar (ISR) observations, and found that the multi-source data fusion was effective and reliable to reconstruct electron density, showing its superiority than CIT with GPS data alone.

  18. Use of a computerized medication shared decision making tool in community mental health settings: impact on psychotropic medication adherence.

    PubMed

    Stein, Bradley D; Kogan, Jane N; Mihalyo, Mark J; Schuster, James; Deegan, Patricia E; Sorbero, Mark J; Drake, Robert E

    2013-04-01

    Healthcare reform emphasizes patient-centered care and shared decision-making. This study examined the impact on psychotropic adherence of a decision support center and computerized tool designed to empower and activate consumers prior to an outpatient medication management visit. Administrative data were used to identify 1,122 Medicaid-enrolled adults receiving psychotropic medication from community mental health centers over a two-year period from community mental health centers. Multivariate linear regression models were used to examine if tool users had higher rates of 180-day medication adherence than non-users. Older clients, Caucasian clients, those without recent hospitalizations, and those who were Medicaid-eligible due to disability had higher rates of 180-day medication adherence. After controlling for sociodemographics, clinical characteristics, baseline adherence, and secular changes over time, using the computerized tool did not affect adherence to psychotropic medications. The computerized decision tool did not affect medication adherence among clients in outpatient mental health clinics. Additional research should clarify the impact of decision-making tools on other important outcomes such as engagement, patient-prescriber communication, quality of care, self-management, and long-term clinical and functional outcomes.

  19. Electronic protocol of respiratory physical therapy in patients with idiopathic adolescent scoliosis.

    PubMed

    Cano, Danila Vieira Baldini; Malafaia, Osvaldo; Alves, Vera Lúcia dos Santos; Avanzi, Osmar; Pinto, José Simão de Paula

    2011-01-01

    To create a clinical database of respiratory function in patients with adolescent idiopathic scoliosis; computerize and store this clinical data through the use of a software; incorporate this electronic protocol to the SINPE© (Integrated Electronic Protocols System) and analyze a pilot project with interpretation of results. From the literature review a computerized data bank of clinical data of postural deviations was set up (master protocol). Upon completion of the master protocol a specific protocol of respiratory function in patients with adolescent idiopathic scoliosis was designed and a pilot project was conducted to collect and analyze data from ten patients. It was possible to create the master protocol of postural deviations and the specific protocol of respiratory function in patients with adolescent idiopathic scoliosis. The data collected in the pilot project was processed by the SINPE ANALYZER©, generating charts and statistics. The establishment of the clinical database of adolescent idiopathic scoliosis was possible. Computerization and storage of clinical data using the software were viable. The electronic protocol of adolescent idiopathic scoliosis could be incorporated into the SINPE© and its use in the pilot project was successful.

  20. [The clinical economic analysis of the methods of ischemic heart disease diagnostics].

    PubMed

    Kalashnikov, V Iu; Mitriagina, S N; Syrkin, A L; Poltavskaia, M G; Sorokina, E G

    2007-01-01

    The clinical economical analysis was applied to assess the application of different techniques of ischemic heart disease diagnostics - the electro-cardiographic monitoring, the treadmill-testing, the stress-echo cardiographic with dobutamine, the single-photon computerized axial tomography with load, the multi-spiral computerized axial tomography with coronary arteries staining in patients with different initial probability of disease occurrence. In all groups, the best value of "cost-effectiveness" had the treadmill-test. The patients with low risk needed 17.4 rubles to precise the probability of ischemic heart disease occurrence at 1%. In the group with medium and high risk this indicator was 9.4 and 24.7 rubles correspondingly. It is concluded that to precise the probability of ischemic heart disease occurrence after tredmil-test in the patients with high probability it is appropriate to use the single-photon computerized axial tomography with load and in the case of patients with low probability the multi-spiral computerized axial tomography with coronary arteries staining.

  1. Combining computerized social cognitive training with neuroplasticity-based auditory training in schizophrenia.

    PubMed

    Sacks, Stephanie; Fisher, Melissa; Garrett, Coleman; Alexander, Phillip; Holland, Christine; Rose, Demian; Hooker, Christine; Vinogradov, Sophia

    2013-01-01

    Social cognitive deficits are an important treatment target in schizophrenia, but it is unclear to what degree they require specialized interventions and which specific components of behavioral interventions are effective. In this pilot study, we explored the effects of a novel computerized neuroplasticity-based auditory training delivered in conjunction with computerized social cognition training (SCT) in patients with schizophrenia. Nineteen clinically stable schizophrenia subjects performed 50 hours of computerized exercises that place implicit, increasing demands on auditory perception, plus 12 hours of computerized training in emotion identification, social perception, and theory of mind tasks. All subjects were assessed with MATRICS-recommended measures of neurocognition and social cognition, plus a measure of self-referential source memory before and after the computerized training. Subjects showed significant improvements on multiple measures of neurocognition. Additionally, subjects showed significant gains on measures of social cognition, including the MSCEIT Perceiving Emotions, MSCEIT Managing Emotions, and self-referential source memory, plus a significant decrease in positive symptoms. Computerized training of auditory processing/verbal learning in schizophrenia results in significant basic neurocognitive gains. Further, addition of computerized social cognition training results in significant gains in several social cognitive outcome measures. Computerized cognitive training that directly targets social cognitive processes can drive improvements in these crucial functions.

  2. The effect of computerized provider order entry systems on clinical care and work processes in emergency departments: a systematic review of the quantitative literature.

    PubMed

    Georgiou, Andrew; Prgomet, Mirela; Paoloni, Richard; Creswick, Nerida; Hordern, Antonia; Walter, Scott; Westbrook, Johanna

    2013-06-01

    We undertake a systematic review of the quantitative literature related to the effect of computerized provider order entry systems in the emergency department (ED). We searched MEDLINE, EMBASE, Inspec, CINAHL, and CPOE.org for English-language studies published between January 1990 and May 2011. We identified 1,063 articles, of which 22 met our inclusion criteria. Sixteen used a pre/post design; 2 were randomized controlled trials. Twelve studies reported outcomes related to patient flow/clinical work, 7 examined decision support systems, and 6 reported effects on patient safety. There were no studies that measured decision support systems and its effect on patient flow/clinical work. Computerized provider order entry was associated with an increase in time spent on computers (up to 16.2% for nurses and 11.3% for physicians), with no significant change in time spent on patient care. Computerized provider order entry with decision support systems was related to significant decreases in prescribing errors (ranging from 17 to 201 errors per 100 orders), potential adverse drug events (0.9 per 100 orders), and prescribing of excessive dosages (31% decrease for a targeted set of renal disease medications). There are tangible benefits associated with computerized provider order entry/decision support systems in the ED environment. Nevertheless, when considered as part of a framework of technical, clinical, and organizational components of the ED, the evidence base is neither consistent nor comprehensive. Multimethod research approaches (including qualitative research) can contribute to understanding of the multiple dimensions of ED care delivery, not as separate entities but as essential components of a highly integrated system of care. Copyright © 2013 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  3. Clinical multiphoton FLIM tomography

    NASA Astrophysics Data System (ADS)

    König, Karsten

    2012-03-01

    This paper gives an overview on current clinical high resolution multiphoton fluorescence lifetime imaging in volunteers and patients. Fluorescence lifetime imaging (FLIM) in Life Sciences was introduced in Jena/Germany in 1988/89 based on a ZEISS confocal picosecond dye laser scanning microscope equipped with a single photon counting unit. The porphyrin distribution in living cells and living tumor-bearing mice was studied with high spatial, temporal, and spectral resolution. Ten years later, time-gated cameras were employed to detect dental caries in volunteers based on one-photon excitation of autofluorescent bacteria with long fluorescence lifetimes. Nowadays, one-photon FLIM based on picosecond VIS laser diodes are used to study ocular diseases in humans. Already one decade ago, first clinical twophoton FLIM images in humans were taken with the certified clinical multiphoton femtosecond laser tomograph DermaInspectTM. Multiphoton tomographs with FLIM modules are now operating in hospitals at Brisbane, Tokyo, Berlin, Paris, London, Modena and other European cities. Multiple FLIM detectors allow spectral FLIM with a temporal resolution down to 20 ps (MCP) / 250 ps (PMT) and a spectral resolution of 10 nm. Major FLIM applications include the detection of intradermal sunscreen and tattoo nanoparticles, the detection of different melanin types, the early diagnosis of dermatitis and malignant melanoma, as well as the measurement of therapeutic effects in pateints suffering from dermatitis. So far, more than 1,000 patients and volunteers have been investigated with the clinical multiphoton FLIM tomographs DermaInspectTM and MPTflexTM.

  4. Successful Resection of a Large Carotid Body Tumor Masquerading Complete Encasement of the Internal Carotid Artery on Preoperative Imaging.

    PubMed

    Kakkos, Stavros K; Zampakis, Peter; Lampropoulos, George C; Paridis, Leonidas; Kaplanis, Charalampos; Bantouna, Dimitra; Nikolakopoulos, Konstantinos M; Papageorgopoulou, Chrysanthi P; Kalogeropoulou, Christina; Tsolakis, Ioannis A

    2018-05-01

    A 41-year-old woman presented with a large painful and tender mass of the left side of her neck located just below the angle of the mandible. She was also complaining of frequent attacks of symptoms ranging from dizziness upon resuming the erect position to frank syncope. Color-coded duplex showed a large well-vascularized vascular mass at the level of the carotid bifurcation, suggesting the diagnosis of a carotid body tumor (CBT). A computerized tomographic angiography confirmed the diagnosis of a CBT, which measured 5.7 cm in its craniocaudal axis. The tumor appeared to encase the internal carotid artery (ICA) at the level of its origin, indicating the presence of a Shamblin group 3 tumor. During surgery, the CBT seemingly encased the ICA; however, it was successfully taken off the ICA, by establishing an adventitial dissection place, obviating the need for arterial resection and replacement. A brief intraoperative episode of cardiac arrest was successfully managed. Postoperative course was uneventful, and all symptoms were cured. Pathology confirmed the clinical diagnosis and did not show malignancy. In conclusion, meticulous surgical techniques can spare the ICA from removal or inadvertent injury during CBT surgery and reduce the morbidity often associated with the resection of large or advanced tumors but also cure atypical patient symptoms.

  5. Validation of a Self-Administered Computerized System to Detect Cognitive Impairment in Older Adults

    PubMed Central

    Brinkman, Samuel D.; Reese, Robert J.; Norsworthy, Larry A.; Dellaria, Donna K.; Kinkade, Jacob W.; Benge, Jared; Brown, Kimberly; Ratka, Anna; Simpkins, James W.

    2015-01-01

    There is increasing interest in the development of economical and accurate approaches to identifying persons in the community who have mild, undetected cognitive impairments. Computerized assessment systems have been suggested as a viable approach to identifying these persons. The validity of a computerized assessment system for identification of memory and executive deficits in older individuals was evaluated in the current study. Volunteers (N = 235) completed a 3-hr battery of neuropsychological tests and a computerized cognitive assessment system. Participants were classified as impaired (n = 78) or unimpaired (n = 157) on the basis of the Mini Mental State Exam, Wechsler Memory Scale-III and the Trail Making Test (TMT), Part B. All six variables (three memory variables and three executive variables) derived from the computerized assessment differed significantly between groups in the expected direction. There was also evidence of temporal stability and concurrent validity. Application of computerized assessment systems for clinical practice and for identification of research participants is discussed in this article. PMID:25332303

  6. Initial clinical experience with computerized tomography of the body.

    PubMed

    Stephens, D H; Sheedy, P F; Hattery, R R; Hartman, G W

    1976-04-01

    Computerized tomography of the body, now possible with an instrument that can complete a scan rapidly enough to permit patients to suspend respiration, adds an important new dimension to radiologic diagnosis. Cross-sectional antomy is uniquely reconstructed to provide accurate diagnostic information for various disorders throughout the body.

  7. Computerized Grading of Anatomy Laboratory Practical Examinations

    ERIC Educational Resources Information Center

    Krippendorf, Beth B.; Bolender, David L.; Kolesari, Gary L.

    2008-01-01

    At the Medical College of Wisconsin, a procedure was developed to allow computerized grading and grade reporting of laboratory practical examinations in the Clinical Human Anatomy course. At the start of the course, first year medical students were given four Lists of Structures. On these lists, numbered items were arranged alphabetically; the…

  8. Information technology and medication safety: what is the benefit?

    PubMed Central

    Kaushal, R; Bates, D

    2002-01-01

    

 Medication errors occur frequently and have significant clinical and financial consequences. Several types of information technologies can be used to decrease rates of medication errors. Computerized physician order entry with decision support significantly reduces serious inpatient medication error rates in adults. Other available information technologies that may prove effective for inpatients include computerized medication administration records, robots, automated pharmacy systems, bar coding, "smart" intravenous devices, and computerized discharge prescriptions and instructions. In outpatients, computerization of prescribing and patient oriented approaches such as personalized web pages and delivery of web based information may be important. Public and private mandates for information technology interventions are growing, but further development, application, evaluation, and dissemination are required. PMID:12486992

  9. Scaled Anatomical Model Creation of Biomedical Tomographic Imaging Data and Associated Labels for Subsequent Sub-surface Laser Engraving (SSLE) of Glass Crystals

    PubMed Central

    Dethlefs, Christopher R.; Piotrowicz, Justin; Van Avermaete, Tony; Maki, Jeff; Gerstler, Steve; Leevy, W. M.

    2017-01-01

    Biomedical imaging modalities like computed tomography (CT) and magnetic resonance (MR) provide excellent platforms for collecting three-dimensional data sets of patient or specimen anatomy in clinical or preclinical settings. However, the use of a virtual, on-screen display limits the ability of these tomographic images to fully convey the anatomical information embedded within. One solution is to interface a biomedical imaging data set with 3D printing technology to generate a physical replica. Here we detail a complementary method to visualize tomographic imaging data with a hand-held model: Sub Surface Laser Engraving (SSLE) of crystal glass. SSLE offers several unique benefits including: the facile ability to include anatomical labels, as well as a scale bar; streamlined multipart assembly of complex structures in one medium; high resolution in the X, Y, and Z planes; and semi-transparent shells for visualization of internal anatomical substructures. Here we demonstrate the process of SSLE with CT data sets derived from pre-clinical and clinical sources. This protocol will serve as a powerful and inexpensive new tool with which to visualize complex anatomical structures for scientists and students in a number of educational and research settings. PMID:28518066

  10. Computed tomographic analysis of temporal maxillary stability and pterygomaxillary generate formation following pediatric Le Fort III distraction advancement.

    PubMed

    Hopper, Richard A; Sandercoe, Gavin; Woo, Albert; Watts, Robyn; Kelley, Patrick; Ettinger, Russell E; Saltzman, Babette

    2010-11-01

    Le Fort III distraction requires generation of bone in the pterygomaxillary region. The authors performed retrospective digital analysis on temporal fine-cut computed tomographic images to quantify both radiographic evidence of pterygomaxillary region bone formation and relative maxillary stability. Fifteen patients with syndromic midface hypoplasia were included in the study. The average age of the patients was 8.7 years; 11 had either Crouzon or Apert syndrome. The average displacement of the maxilla during distraction was 16.2 mm (range, 7 to 31 mm). Digital analysis was performed on fine-cut computed tomographic scans before surgery, at device removal, and at annual follow-up. Seven patients also had mid-consolidation computed tomographic scans. Relative maxillary stability and density of radiographic bone in the pterygomaxillary region were calculated between each scan. There was no evidence of clinically significant maxillary relapse, rotation, or growth between the end of consolidation and 1-year follow-up, other than a relatively small 2-mm subnasal maxillary vertical growth. There was an average radiographic ossification of 0.5 mm/mm advancement at the time of device removal, with a 25th percentile value of 0.3 mm/mm. The time during consolidation that each patient reached the 25th percentile of pterygomaxillary region bone density observed in this series of clinically stable advancements ranged from 1.3 to 9.8 weeks (average, 3.7 weeks). There was high variability in the amount of bone formed in the pterygomaxillary region associated with clinical stability of the advanced Le Fort III segment. These data suggest that a subsection of patients generate the minimal amount of pterygomaxillary region bone formation associated with advancement stability as early as 4 weeks into consolidation.

  11. A novel clinical multimodal multiphoton tomograph for AF, SHG, CARS imaging, and FLIM

    NASA Astrophysics Data System (ADS)

    Weinigel, Martin; Breunig, Hans Georg; König, Karsten

    2014-02-01

    We report on a flexible nonlinear medical tomograph with multiple miniaturized detectors for simultaneous acquisition of two-photon autofluorescence (AF), second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) images. The simultaneous visualization of the distribution of endogenous fluorophores NAD(P)H, melanin and elastin, SHG-active collagen and as well as non-fluorescent lipids within human skin in vivo is possible. Furthermore, fluorescence lifetime images (FLIM) can be generated using time-correlated single photon counting.

  12. Influence of Computerized Sounding Out on Spelling Performance for Children who do and not rely on AAC

    PubMed Central

    McCarthy, Jillian H.; Hogan, Tiffany P.; Beukelman, David R.; Schwarz, Ilsa E.

    2015-01-01

    Purpose Spelling is an important skill for individuals who rely on augmentative alternative communication (AAC). The purpose of this study was to investigate how computerized sounding out influenced spelling accuracy of pseudo-words. Computerized sounding out was defined as a word elongated, thus providing an opportunity for a child to hear all the sounds in the word at a slower rate. Methods Seven children with cerebral palsy, four who use AAC and three who do not, participated in a single subject AB design. Results The results of the study indicated that the use of computerized sounding out increased the phonologic accuracy of the pseudo-words produced by participants. Conclusion The study provides preliminary evidence for the use of computerized sounding out during spelling tasks for children with cerebral palsy who do and do not use AAC. Future directions and clinical implications are discussed. PMID:24512195

  13. 1975 Memorial Award Paper. Image generation and display techniques for CT scan data. Thin transverse and reconstructed coronal and sagittal planes.

    PubMed

    Glenn, W V; Johnston, R J; Morton, P E; Dwyer, S J

    1975-01-01

    The various limitations to computerized axial tomographic (CT) interpretation are due in part to the 8-13 mm standard tissue plane thickness and in part to the absence of alternative planes of view, such as coronal or sagittal images. This paper describes a method for gathering multiple overlapped 8 mm transverse sections, subjecting these data to a deconvolution process, and then displaying thin (1 mm) transverse as well as reconstructed coronal and sagittal CT images. Verification of the deconvolution technique with phantom experiments is described. Application of the phantom results to human post mortem CT scan data illustrates this method's faithful reconstruction of coronal and sagittal tissue densities when correlated with actual specimen photographs of a sectioned brain. A special CT procedure, limited basal overlap scanning, is proposed for use on current first generation CT scanners without hardware modification.

  14. Cerebrospinal fluid flow abnormalities in patients with neoplastic meningitis. An evaluation using /sup 111/In-DTPA ventriculography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grossman, S.A.; Trump, D.L.; Chen, D.C.

    1982-11-01

    Cerebrospinal fluid flow dynamics were evaluated by /sup 111/In-diethylenetriamine pentaacetic acid (/sup 111/In-DTPA) ventriculography in 27 patients with neoplastic meningitis. Nineteen patients (70 percent) had evidence of cerebrospinal fluid flow disturbances. These occurred as ventricular outlet obstructions, abnormalities of flow in the spinal canal, or flow distrubances over the cortical convexities. Tumor histology, physical examination, cerebrospinal fluid analysis, myelograms, and computerized axial tomographic scans were not sufficient to predict cerebrospinal fluid flow patterns. These data indicate that cerebrospinal fluid flow abnormalities are common in patients with neoplastic meningitis and that /sup 111/In-DTPA cerebrospinal fluid flow imaging is useful in characterizingmore » these abnormalities. This technique provides insight into the distribution of intraventricularly administered chemotherapy and may provide explanations for treatment failure and drug-induced neurotoxicity in patients with neoplastic meningitis.« less

  15. Vertical structure of medium-scale traveling ionospheric disturbances

    NASA Astrophysics Data System (ADS)

    Ssessanga, Nicholas; Kim, Yong Ha; Kim, Eunsol

    2015-11-01

    We develop an algorithm of computerized ionospheric tomography (CIT) to infer information on the vertical and horizontal structuring of electron density during nighttime medium-scale traveling ionospheric disturbances (MSTIDs). To facilitate digital CIT we have adopted total electron contents (TEC) from a dense Global Positioning System (GPS) receiver network, GEONET, which contains more than 1000 receivers. A multiplicative algebraic reconstruction technique was utilized with a calibrated IRI-2012 model as an initial solution. The reconstructed F2 peak layer varied in altitude with average peak-to-peak amplitude of ~52 km. In addition, the F2 peak layer anticorrelated with TEC variations. This feature supports a theory in which nighttime MSTID is composed of oscillating electric fields due to conductivity variations. Moreover, reconstructed TEC variations over two stations were reasonably close to variations directly derived from the measured TEC data set. Our tomographic analysis may thus help understand three-dimensional structure of MSTIDs in a quantitative way.

  16. Measurement of absolute lung volumes by imaging techniques.

    PubMed

    Clausen, J

    1997-10-01

    In this paper, the techniques available for estimating total lung capacities from standard chest radiographs in children and infants as well as adults are reviewed. These techniques include manual measurements using ellipsoid and planimetry techniques as well as computerized systems. Techniques are also available for making radiographic lung volume measurements from portable chest radiographs. There are inadequate data in the literature to support recommending one specific technique over another. Though measurements of lung volumes by radiographic, plethysmographic, gas dilution or washout techniques result in remarkably similar mean results when groups of normal subjects are tested, in patients with disease, the results of these different basic measurement techniques can differ significantly. Computed tomographic and magnetic resonance techniques can also be used to measure absolute lung volumes and offer the theoretical advantages that the results in individual subjects are less affected by variances of thoracic shape than are measurements made using conventional chest radiographs.

  17. Technical report on semiautomatic segmentation using the Adobe Photoshop.

    PubMed

    Park, Jin Seo; Chung, Min Suk; Hwang, Sung Bae; Lee, Yong Sook; Har, Dong-Hwan

    2005-12-01

    The purpose of this research is to enable users to semiautomatically segment the anatomical structures in magnetic resonance images (MRIs), computerized tomographs (CTs), and other medical images on a personal computer. The segmented images are used for making 3D images, which are helpful to medical education and research. To achieve this purpose, the following trials were performed. The entire body of a volunteer was scanned to make 557 MRIs. On Adobe Photoshop, contours of 19 anatomical structures in the MRIs were semiautomatically drawn using MAGNETIC LASSO TOOL and manually corrected using either LASSO TOOL or DIRECT SELECTION TOOL to make 557 segmented images. In a similar manner, 13 anatomical structures in 8,590 anatomical images were segmented. Proper segmentation was verified by making 3D images from the segmented images. Semiautomatic segmentation using Adobe Photoshop is expected to be widely used for segmentation of anatomical structures in various medical images.

  18. Computerized Virtual Reality Simulation in Preclinical Dentistry: Can a Computerized Simulator Replace the Conventional Phantom Heads and Human Instruction?

    PubMed

    Plessas, Anastasios

    2017-10-01

    In preclinical dental education, the acquisition of clinical, technical skills, and the transfer of these skills to the clinic are paramount. Phantom heads provide an efficient way to teach preclinical students dental procedures safely while increasing their dexterity skills considerably. Modern computerized phantom head training units incorporate features of virtual reality technology and the ability to offer concurrent augmented feedback. The aims of this review were to examine and evaluate the dental literature for evidence supporting their use and to discuss the role of augmented feedback versus the facilitator's instruction. Adjunctive training in these units seems to enhance student's learning and skill acquisition and reduce the required faculty supervision time. However, the virtual augmented feedback cannot be used as the sole method of feedback, and the facilitator's input is still critical. Well-powered longitudinal randomized trials exploring the impact of these units on student's clinical performance and issues of cost-effectiveness are warranted.

  19. The Impact of Interactive, Computerized Educational Modules on Preclinical Medical Education

    ERIC Educational Resources Information Center

    Bryner, Benjamin S.; Saddawi-Konefka, Daniel; Gest, Thomas R.

    2008-01-01

    Interactive computerized modules have been linked to improved retention of material in clinical medicine. This study examined the effects of a new series of interactive learning modules for preclinical medical education, specifically in the areas of quiz performance, perceived difficulty of concepts, study time, and perceived stress level. We…

  20. Evaluation of the Computerized Assessment System for Psychotherapy Evaluation and Research (CASPER) as a Measure of Treatment Effectiveness with Psychiatric Inpatients

    ERIC Educational Resources Information Center

    Kinnaman, Joanna E. Strong; Farrell, Albert D.; Bisconer, Sarah W.

    2006-01-01

    Assessment procedures to evaluate inpatient treatment effectiveness can provide information to inform clinical practice. The Computerized Assessment System for Psychotherapy Evaluation and Research (CASPER) represents a standardized approach to assess patients' target problems that combines elements of individualized and nomothetic approaches.…

  1. Accuracy of a computerized clinical decision-support system for asthma assessment and management.

    PubMed

    Hoeksema, Laura J; Bazzy-Asaad, Alia; Lomotan, Edwin A; Edmonds, Diana E; Ramírez-Garnica, Gabriela; Shiffman, Richard N; Horwitz, Leora I

    2011-05-01

    To evaluate the accuracy of a computerized clinical decision-support system (CDSS) designed to support assessment and management of pediatric asthma in a subspecialty clinic. Cohort study of all asthma visits to pediatric pulmonology from January to December, 2009. CDSS and physician assessments of asthma severity, control, and treatment step. Both the clinician and the computerized CDSS generated assessments of asthma control in 767/1032 (74.3%) return patients, assessments of asthma severity in 100/167 (59.9%) new patients, and recommendations for treatment step in 66/167 (39.5%) new patients. Clinicians agreed with the CDSS in 543/767 (70.8%) of control assessments, 37/100 (37%) of severity assessments, and 19/66 (29%) of step recommendations. External review classified 72% of control disagreements (21% of all control assessments), 56% of severity disagreements (37% of all severity assessments), and 76% of step disagreements (54% of all step recommendations) as CDSS errors. The remaining disagreements resulted from pulmonologist error or ambiguous guidelines. Many CDSS flaws, such as attributing all 'cough' to asthma, were easily remediable. Pediatric pulmonologists failed to follow guidelines in 8% of return visits and 18% of new visits. The authors relied on chart notes to determine clinical reasoning. Physicians may have changed their assessments after seeing CDSS recommendations. A computerized CDSS performed relatively accurately compared to clinicians for assessment of asthma control but was inaccurate for treatment. Pediatric pulmonologists failed to follow guideline-based care in a small proportion of patients.

  2. Three-dimensional tomographic mapping related to primary stability and structural miniscrew characteristics.

    PubMed

    Silvestrini Biavati, A; Tecco, S; Migliorati, M; Festa, F; Panza, G; Marzo, G; Gherlone, E; Tetè, S

    2011-05-01

    To evaluate the maxilla, mandible, and cortical plates on computerized tomographic (CT) scans to achieve accurate three-dimensional bone thickness measurements. We selected the CT scans of 25 subjects (among 102), aged 18-58 years (10 men, 15 women), with nearly complete dentition. We performed interradicular and bucco-lingual (including cortical plate thickness) measurements in dental areas distal to the canines in both alveolar arches, at three levels (5, 8, and 11 mm) from the alveolar ridge. The mean thicknesses of the cortical plates in the maxilla were 1.10 mm buccally and 1.27 mm on the palatal side (p < 0.05). In the mandible, cortical plates were 2.23 mm buccally and 2.02 mm lingually. Mandibular buccal and lingual cortical plates became thicker distally in the second and third molar areas. There was considerable variation in cortical thickness (from 0.25 to 5.50 mm). Based on interradicular distances, only 13% of measured sites in the maxilla were suitable for miniscrew insertion (≥3.3 mm), but 63% of sites were suitable in the mandible. This study showed considerable individual variation in bone thickness. Our data suggested that the palatal/lingual side may provide greater primary stability for miniscrews. The palatal area, between the second upper bicuspid and the first molar, appeared to be the most suitable area for tapered 7- to 9-mm miniscrews, starting at 1.5-2 mm from the alveolar crest. © 2011 John Wiley & Sons A/S.

  3. Laterality and Left-sidedness in the Nose, Face, and Body: A New Finding.

    PubMed

    Hafezi, Farhad; Javdani, Ali; Naghibzadeh, Bijan; Ashtiani, Abbas Kazemi

    2017-12-01

    Asymmetry is a common occurrence in bilaterian animals, particularly human beings. Through examination of patients and their photographs during rhinoplasty, we noted wider left-sided nasal and facial features in most patients. This observation led us to hypothesize that this might be consistent to the whole body. We conducted a study in 3 parts to test the question above. First, we analyzed operating notes of 50 rhinoplasty patients to determine the wider side of the upper, middle, and lower thirds of the nose. Second, we analyzed the width of the face and chest wall in 31 patients to discern any correlation between facial and bodily asymmetry. Third, computerized tomographic scans of the thorax and body of 48 patients were studied to measure the width of the hemithorax and hemipelvic bone. (1) Upper vault width was wider on left side (78%). Left middle vault width was wider (88%). The lower lateral cartilage, lateral crura convexity was more prominent on left side (48%), and a wider scroll area was found and trimmed in 21 (left) and 0 (right) cases. The alar base was wider on left side (56%). (2) In the body and face analysis, 64.5% had a wider left-sided face and body. (3) In the computed tomographic scan analysis, same-sided thorax and pelvis asymmetry was seen (85.35%), 33 and 7 of which were left- and right-sided, respectively. We observed generalized asymmetry of the face and body with left-sided predominance.

  4. Computerized Respiratory Sounds: Novel Outcomes for Pulmonary Rehabilitation in COPD.

    PubMed

    Jácome, Cristina; Marques, Alda

    2017-02-01

    Computerized respiratory sounds are a simple and noninvasive measure to assess lung function. Nevertheless, their potential to detect changes after pulmonary rehabilitation (PR) is unknown and needs clarification if respiratory acoustics are to be used in clinical practice. Thus, this study investigated the short- and mid-term effects of PR on computerized respiratory sounds in subjects with COPD. Forty-one subjects with COPD completed a 12-week PR program and a 3-month follow-up. Secondary outcome measures included dyspnea, self-reported sputum, FEV 1 , exercise tolerance, self-reported physical activity, health-related quality of life, and peripheral muscle strength. Computerized respiratory sounds, the primary outcomes, were recorded at right/left posterior chest using 2 stethoscopes. Air flow was recorded with a pneumotachograph. Normal respiratory sounds, crackles, and wheezes were analyzed with validated algorithms. There was a significant effect over time in all secondary outcomes, with the exception of FEV 1 and of the impact domain of the St George Respiratory Questionnaire. Inspiratory and expiratory median frequencies of normal respiratory sounds in the 100-300 Hz band were significantly lower immediately (-2.3 Hz [95% CI -4 to -0.7] and -1.9 Hz [95% CI -3.3 to -0.5]) and at 3 months (-2.1 Hz [95% CI -3.6 to -0.7] and -2 Hz [95% CI -3.6 to -0.5]) post-PR. The mean number of expiratory crackles (-0.8, 95% CI -1.3 to -0.3) and inspiratory wheeze occupation rate (median 5.9 vs 0) were significantly lower immediately post-PR. Computerized respiratory sounds were sensitive to short- and mid-term effects of PR in subjects with COPD. These findings are encouraging for the clinical use of respiratory acoustics. Future research is needed to strengthen these findings and explore the potential of computerized respiratory sounds to assess the effectiveness of other clinical interventions in COPD. Copyright © 2017 by Daedalus Enterprises.

  5. Regulatory issues for computerized electrocardiographic devices.

    PubMed

    Muni, Neal I; Ho, Charles; Mallis, Elias

    2004-01-01

    Computerized electrocardiogram (ECG) devices are regulated in the U.S. by the FDA Center for Devices and Radiological Health (CDRH). This article aims to highlight the salient points of the FDA regulatory review process, including the important distinction between a "tool" claim and a "clinical" claim in the intended use of a computerized ECG device. Specifically, a tool claim relates to the ability of the device to accurately measure a certain ECG parameter, such as T-wave alternans (TWA), while a clinical claim imputes a particular health hazard associated with the identified parameter, such as increased risk of ventricular tachyarrhythmia or sudden death. Given that both types of claims are equally important and receive the same regulatory scrutiny, the manufacturer of a new ECG diagnostic device should consider the distinction and regulatory pathways for approval between the two types of claims discussed in this paper.

  6. In vivo histology: optical biopsies with chemical contrast using clinical multiphoton/coherent anti-Stokes Raman scattering tomography

    NASA Astrophysics Data System (ADS)

    Weinigel, M.; Breunig, H. G.; Kellner-Höfer, M.; Bückle, R.; Darvin, M. E.; Klemp, M.; Lademann, J.; König, K.

    2014-05-01

    The majority of existing coherent anti-Stokes Raman scattering (CARS) imaging systems are still huge and complicated laboratory systems and neither compact nor user-friendly nor mobile medically certified CARS systems. We have developed a new flexible multiphoton/CARS tomograph for imaging in a clinical environment. The system offers exceptional 360° flexibility with a very stable setup and enables label free ‘in vivo histology’ with chemical contrast within seconds. It can be completely operated by briefly trained non-laser experts. The imaging capability and flexibility of the novel in vivo tomograph are shown on optical biopsies with subcellular resolution and chemical contrast of patients suffering from psoriasis and squamous cell carcinoma.

  7. Positron Emission Tomography: Principles, Technology, and Recent Developments

    NASA Astrophysics Data System (ADS)

    Ziegler, Sibylle I.

    2005-04-01

    Positron emission tomography (PET) is a nuclear medical imaging technique for quantitative measurement of physiologic parameters in vivo (an overview of principles and applications can be found in [P.E. Valk, et al., eds. Positron Emission Tomography. Basic Science and Clinical Practice. 2003, Springer: Heidelberg]), based on the detection of small amounts of posi-tron-emitter-labelled biologic molecules. Various radiotracers are available for neuro-logical, cardiological, and oncological applications in the clinic and in research proto-cols. This overview describes the basic principles, technology, and recent develop-ments in PET, followed by a section on the development of a tomograph with ava-lanche photodiodes dedicated for small animal imaging as an example of efforts in the domain of high resolution tomographs.

  8. Clinical clearance of the cervical spine in patients with distracting injuries: It is time to dispel the myth.

    PubMed

    Rose, Melanie K; Rosal, Lindy M; Gonzalez, Richard P; Rostas, Jack W; Baker, Jeremy A; Simmons, Jon D; Frotan, Mohammed A; Brevard, Sydney B

    2012-08-01

    The purpose of this study was to prospectively assess the sensitivity and efficacy of clinical examination for screening of cervical spine (c-spine) injury in awake and alert blunt trauma patients with concomitant "distracting injuries." During the 24-month period from December 2009 to December 2011, all blunt trauma patients older than 13 years were prospectively evaluated with a standard cervical spine examination protocol by the trauma surgery team at a Level 1 trauma center. Awake and alert patients with a Glasgow Coma Score (GCS) ≥14 underwent clinical examination of the cervical spine. Clinical examination was performed regardless of "distracting injuries." Patients without complaints of pain or tenderness on physical exam had their cervical collar removed, and the c-spine was considered clinically cleared of injury. All awake and alert patients with "distracting injuries," including those clinically cleared and those with complaints of c-spine pain or tenderness underwent computerized tomographic (CT) scanning of the entire c-spine. "Distracting injuries" were categorized into three anatomic regions: head injuries, torso injuries and long bone fractures. Patients with minor distracting injuries were not considered to have a "distracting injury." During the 24-month study period, 761 blunt trauma patients with GCS ≥14 and at least one "distracting injury" had been entered into the study protocol. Two-hundred ninety-six (39%) of the patients with "distracting injuries" had a positive c-spine clinical examination, 85 (29%) of whom were diagnosed with c-spine injury. Four hundred sixty-four (61%) of the patients with "distracting injuries"’ were initially clinically cleared, with one patient (0.2%) diagnosed with a c-spine injury. This yielded an overall sensitivity of 99% (85/86) and negative predictive value greater than 99% (463/464) for cervical spine clinical examination in awake and alert blunt trauma patients with "distracting injuries." In the awake and alert blunt trauma patient with "distracting injuries," clinical examination is a sensitive screening method for cervical spine injury. Radiological assessment is unnecessary for safe clearance of the asymptomatic cervical spine in awake and alert blunt trauma patients with "distracting injuries." These findings suggest the concept of "distracting injury" in the context of cervical spine clinical examination is invalid. Expanding the utility of cervical spine clinical examination to patients with "distracting injuries" allows for significant reduction of both healthcare cost and radiation exposure.

  9. Experimental Actinobacillus pleuropneumoniae challenge in swine: Comparison of computed tomographic and radiographic findings during disease

    PubMed Central

    2012-01-01

    Background In pigs, diseases of the respiratory tract like pleuropneumonia due to Actinobacillus pleuropneumoniae (App) infection have led to high economic losses for decades. Further research on disease pathogenesis, pathogen-host-interactions and new prophylactic and therapeutic approaches are needed. In most studies, a large number of experimental animals are required to assess lung alterations at different stages of the disease. In order to reduce the required number of animals but nevertheless gather information on the nature and extent of lung alterations in living pigs, a computed tomographic scoring system for quantifying gross pathological findings was developed. In this study, five healthy pigs served as control animals while 24 pigs were infected with App, the causative agent of pleuropneumonia in pigs, in an established model for respiratory tract disease. Results Computed tomographic (CT) findings during the course of App challenge were verified by radiological imaging, clinical, serological, gross pathology and histological examinations. Findings from clinical examinations and both CT and radiological imaging, were recorded on day 7 and day 21 after challenge. Clinical signs after experimental App challenge were indicative of acute to chronic disease. Lung CT findings of infected pigs comprised ground-glass opacities and consolidation. On day 7 and 21 the clinical scores significantly correlated with the scores of both imaging techniques. At day 21, significant correlations were found between clinical scores, CT scores and lung lesion scores. In 19 out of 22 challenged pigs the determined disease grades (not affected, slightly affected, moderately affected, severely affected) from CT and gross pathological examination were in accordance. Disease classification by radiography and gross pathology agreed in 11 out of 24 pigs. Conclusions High-resolution, high-contrast CT examination with no overlapping of organs is superior to radiography in the assessment of pneumonic lung lesions after App challenge. The new CT scoring system allows for quantification of gross pathological lung alterations in living pigs. However, computed tomographic findings are not informative of the etiology of respiratory disease. PMID:22546414

  10. Influence of computerized sounding out on spelling performance for children who do and do not rely on AAC.

    PubMed

    McCarthy, Jillian H; Hogan, Tiffany P; Beukelman, David R; Schwarz, Ilsa E

    2015-05-01

    Spelling is an important skill for individuals who rely on augmentative and alternative communication (AAC). The purpose of this study was to investigate how computerized sounding out influenced spelling accuracy of pseudo-words. Computerized sounding out was defined as a word elongated, thus providing an opportunity for a child to hear all the sounds in the word at a slower rate. Seven children with cerebral palsy, four who use AAC and three who do not, participated in a single subject AB design. The results of the study indicated that the use of computerized sounding out increased the phonologic accuracy of the pseudo-words produced by participants. The study provides preliminary evidence for the use of computerized sounding out during spelling tasks for children with cerebral palsy who do and do not use AAC. Future directions and clinical implications are discussed. We investigated how computerized sounding out influenced spelling accuracy of pseudowords for children with complex communication needs who did and did not use augmentative and alternative communication (AAC). Results indicated that the use of computerized sounding out increased the phonologic accuracy of the pseudo-words by participants, suggesting that computerized sounding out might assist in more accurate spelling for children who use AAC. Future research is needed to determine how language and reading abilities influence the use of computerized sounding out with children who have a range of speech intelligibility abilities and do and do not use AAC.

  11. The process of development of a prioritization tool for a clinical decision support build within a computerized provider order entry system: Experiences from St Luke's Health System.

    PubMed

    Wolf, Matthew; Miller, Suzanne; DeJong, Doug; House, John A; Dirks, Carl; Beasley, Brent

    2016-09-01

    To establish a process for the development of a prioritization tool for a clinical decision support build within a computerized provider order entry system and concurrently to prioritize alerts for Saint Luke's Health System. The process of prioritizing clinical decision support alerts included (a) consensus sessions to establish a prioritization process and identify clinical decision support alerts through a modified Delphi process and (b) a clinical decision support survey to validate the results. All members of our health system's physician quality organization, Saint Luke's Care as well as clinicians, administrators, and pharmacy staff throughout Saint Luke's Health System, were invited to participate in this confidential survey. The consensus sessions yielded a prioritization process through alert contextualization and associated Likert-type scales. Utilizing this process, the clinical decision support survey polled the opinions of 850 clinicians with a 64.7 percent response rate. Three of the top rated alerts were approved for the pre-implementation build at Saint Luke's Health System: Acute Myocardial Infarction Core Measure Sets, Deep Vein Thrombosis Prophylaxis within 4 h, and Criteria for Sepsis. This study establishes a process for developing a prioritization tool for a clinical decision support build within a computerized provider order entry system that may be applicable to similar institutions. © The Author(s) 2015.

  12. Comparing Assessments of Students' Knowledge by Computerized Open-Ended and Multiple-Choice Tests.

    ERIC Educational Resources Information Center

    Anbar, Michael

    1991-01-01

    Interactive computerized tests accepting unrestricted natural-language input were used to assess knowledge of clinical biophysics at the State University of New York at Buffalo. Comparison of responses to open-ended sequential questions and multiple-choice questions on the same material found the two formats test different aspects of competence.…

  13. Effect of Sandostatin LAR on sleep apnoea in acromegaly: correlation with computerized tomographic cephalometry and hormonal activity.

    PubMed

    Ip, M S; Tan, K C; Peh, W C; Lam, K S

    2001-10-01

    Sleep apnoea has been reported to occur in subjects with acromegaly. This study evaluates the relationship among biochemical activity, sleep apnoeic activity and upper airway anatomic profile in acromegaly, and the effect of Sandostatin LAR, a long-acting somatostatin analogue, on these parameters. Fourteen subjects with acromegaly were recruited. Subjects were assessed at baseline and those with apnoea-hypopnoea index (AHI) > or = 5 were reassessed after 6 months of treatment with Sandostatin LAR 20-30 mg IMI 4-weekly. Biochemical activity was assessed with levels of GH and IGF-1. Sleep disordered breathing was assessed with overnight polysomnography. Upper airway anatomic profile was defined with computerized tomographic cephalometry. Of 14 subjects (age 42.0 +/- 8.1 years, mean +/- SD; 11 men) at baseline, there was a positive correlation between GH and tongue length (VT; P = 0.004), and between AHI and cephalometric indices: length of soft palate (PMU; P = 0.002); mandibular plane-hyoid bone distance (MPH; P = 0.017), maximum thickness of soft palate (Max-SP; P = 0.018) and VT (P = 0.027). Eight patients had sleep disordered breathing (AHI > or = 5) which was predominantly obstructive in nature (AHI = 29.4 +/- 22.6). After treatment, there were significant improvements in hormonal profile: GH, mU/l (before, 51.5 +/- 27.8; after, 8.0 +/- 7.4; P = 0.017) and IGF-1, nmol/l (before, 95.5 +/- 23.4; after, 35.0 +/- 12.4; P = 0.012); sleep-disordered breathing: AHI (before, 29.4 +/- 22.6; after, 13.4 +/- 11.12; P = 0.025), snoring episodes (before, 486 +/- 240; after, 165 +/- 170; P = 0.05); cephalometric indices, mm: MPH (before, 18.8 +/- 12.1; after, 14.8 +/- 8.4; P = 0.018), VT (before, 72.3 +/- 4.4; after, 69.7 +/- 4.3; P = 0.05). There was a positive correlation between the reduction in GH and AHI (r = 0.738, P = 0.037). The findings demonstrated that there was correlation between sleep apnoea severity and soft tissue overgrowth at the upper airway region in acromegaly. They also suggest that Sandostatin LAR improved obstructive sleep apnoea in acromegaly, and the effect might be partly mediated via a reduction in upper airway soft tissue, in particular that of the tongue, concomitant with a reduction in GH levels.

  14. Feasibility and acceptability of a novel, computerized screening and brief intervention (SBI) for alcohol and sweetened beverage use in pregnancy.

    PubMed

    Nayak, Madhabika B; Korcha, Rachael A; Kaskutas, Lee A; Kaskustas, Lee A; Avalos, Lyndsay A

    2014-11-25

    Recommended screening and brief intervention (SBI) for alcohol use during pregnancy is impeded by high patient loads and limited resources in public health settings. We evaluated the feasibility, acceptability and validity of a new self-administered, single-session, bilingual, computerized Screening and Brief Intervention (SBI) program for alcohol and sugar sweetened beverage (SSB) use in pregnancy. We developed and tested the computerized SBI program at a public health clinic with 290 pregnant women. Feasibility, acceptability, and validity measures were included in the program which had several modules, including those on demographics, health and beverage use. Time to complete the program and user experience items were used to determine program feasibility and acceptability. Validity analyses compared proportions of prenatal alcohol use identified by the program versus in-person screening by clinic staff. Most program users (87%, n = 251) completed the entire program; 91% (n = 263) completed the key screening and brief intervention modules. Most users also completed the program in ten to fifteen minutes. Program users reported that the program was easy to use (97%), they learned something new (88%), and that they would share what they learned with others (83%) and with their doctors or clinic staff (76%). Program acceptability did not differ by age, education, or type of beverage intervention received. The program identified alcohol use in pregnancy among 21% of users, a higher rate than the 13% (p < .01) found via screening by clinic staff. Computerized Screening and Brief Intervention for alcohol and SSB use in public health clinics is feasible and acceptable to English and Spanish speaking pregnant women and can efficiently identify prenatal alcohol use.

  15. Evaluation of Internet-Based Clinical Decision Support Systems

    PubMed Central

    Thomas, Karl W; Dayton, Charles S

    1999-01-01

    Background Scientifically based clinical guidelines have become increasingly used to educate physicians and improve quality of care. While individual guidelines are potentially useful, repeated studies have shown that guidelines are ineffective in changing physician behavior. The Internet has evolved as a potentially useful tool for guideline education, dissemination, and implementation because of its open standards and its ability to provide concise, relevant clinical information at the location and time of need. Objective Our objective was to develop and test decision support systems (DSS) based on clinical guidelines which could be delivered over the Internet for two disease models: asthma and tuberculosis (TB) preventive therapy. Methods Using open standards of HTML and CGI, we developed an acute asthma severity assessment DSS and a preventative tuberculosis treatment DSS based on content from national guidelines that are recognized as standards of care. Both DSS's are published on the Internet and operate through a decision algorithm developed from the parent guidelines with clinical information provided by the user at the point of clinical care. We tested the effectiveness of each DSS in influencing physician decisions using clinical scenario testing. Results We first validated the asthma algorithm by comparing asthma experts' decisions with the decisions reached by nonpulmonary nurses using the computerized DSS. Using the DSS, nurses scored the same as experts (89% vs. 88%; p = NS). Using the same scenario test instrument, we next compared internal medicine residents using the DSS with residents using a printed version of the National Asthma Education Program-2 guidelines. Residents using the computerized DSS scored significantly better than residents using the paper-based guidelines (92% vs. 84%; p <0.002). We similarly compared residents using the computerized TB DSS to residents using a printed reference card; the residents using the computerized DSS scored significantly better (95.8% vs. 56.6% correct; p<0.001). Conclusions Previous work has shown that guidelines disseminated through traditional educational interventions have minimal impact on physician behavior. Although computerized DSS have been effective in altering physician behavior, many of these systems are not widely available. We have developed two clinical DSS's based on national guidelines and published them on the Internet. Both systems improved physician compliance with national guidelines when tested in clinical scenarios. By providing information that is coupled to relevant activity, we expect that these widely available DSS's will serve as effective educational tools to positively impact physician behavior. PMID:11720915

  16. Tomographic assessment of the spine in children with spondylocostal dysotosis syndrome.

    PubMed

    Kaissi, Ali Al; Klaushofer, Klaus; Grill, Franz

    2010-01-01

    The aim of this study was to perform a detailed tomographic analysis of the skull base, craniocervical junction, and the entire spine in seven patients with spondylocostal dysostosis syndrome. Detailed scanning images have been organized in accordance with the most prominent clinical pathology. The reasons behind plagiocephaly, torticollis, short immobile neck, scoliosis and rigid back have been detected. Radiographic documentation was insufficient modality. Detailed computed tomography scans provided excellent delineation of the osseous abnormality pattern in our patients. This article throws light on the most serious osseous manifestations of spondylocostal dysostosissyndrome.

  17. Comment on 'Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification'.

    PubMed

    Sitek, Arkadiusz

    2016-12-21

    The origin ensemble (OE) algorithm is a new method used for image reconstruction from nuclear tomographic data. The main advantage of this algorithm is the ease of implementation for complex tomographic models and the sound statistical theory. In this comment, the author provides the basics of the statistical interpretation of OE and gives suggestions for the improvement of the algorithm in the application to prompt gamma imaging as described in Polf et al (2015 Phys. Med. Biol. 60 7085).

  18. Comment on ‘Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification’

    NASA Astrophysics Data System (ADS)

    Sitek, Arkadiusz

    2016-12-01

    The origin ensemble (OE) algorithm is a new method used for image reconstruction from nuclear tomographic data. The main advantage of this algorithm is the ease of implementation for complex tomographic models and the sound statistical theory. In this comment, the author provides the basics of the statistical interpretation of OE and gives suggestions for the improvement of the algorithm in the application to prompt gamma imaging as described in Polf et al (2015 Phys. Med. Biol. 60 7085).

  19. Is there a link between the hospital-acquired injurious fall rates in US acute care hospitals and these institutions' implementation levels of computerized systems?

    PubMed

    Tzeng, Huey-Ming; Hu, Hsou Mei; Yin, Chang-Yi

    2011-12-01

    Medicare no longer reimburses acute care hospitals for the costs of additional care required due to hospital-acquired injuries. Consequently, this study explored the effective computerized systems to inform practice for better interventions to reduce fall risk. It provided a correlation between type of computerized system and hospital-acquired injurious fall rates at acute care hospitals in California, Florida, and New York. It used multiple publicly available data sets, with the hospital as the unit of analysis. Descriptive and Pearson correlation analyses were used. The analysis included 462 hospitals. Significant correlations could be categorized into two groups: (1) meaningful computerized systems that were associated with lower injurious fall rates: the decision support systems for drug allergy alerts, drug-drug interaction alerts, and drug-laboratory interaction alerts; and (2) computerized systems that were associated with higher injurious fall rates: the decision support system for drug-drug interaction alerts and the computerized provider order entry system for radiology tests. Future research may include additional states, multiple years of data, and patient-level data to validate this study's findings. This effort may further inform policy makers and the public about effective clinical computerized systems provided to clinicians to improve their practice decisions and care outcomes.

  20. Arterial Obstruction on Computed Tomographic or Magnetic Resonance Angiography and Response to Intravenous Thrombolytics in Ischemic Stroke

    PubMed Central

    Mair, Grant; von Kummer, Rüdiger; Adami, Alessandro; White, Philip M.; Adams, Matthew E.; Yan, Bernard; Demchuk, Andrew M.; Farrall, Andrew J.; Sellar, Robin J.; Sakka, Eleni; Palmer, Jeb; Perry, David; Lindley, Richard I.; Sandercock, Peter A.G.

    2017-01-01

    Background and Purpose— Computed tomographic angiography and magnetic resonance angiography are used increasingly to assess arterial patency in patients with ischemic stroke. We determined which baseline angiography features predict response to intravenous thrombolytics in ischemic stroke using randomized controlled trial data. Methods— We analyzed angiograms from the IST-3 (Third International Stroke Trial), an international, multicenter, prospective, randomized controlled trial of intravenous alteplase. Readers, masked to clinical, treatment, and outcome data, assessed prerandomization computed tomographic angiography and magnetic resonance angiography for presence, extent, location, and completeness of obstruction and collaterals. We compared angiography findings to 6-month functional outcome (Oxford Handicap Scale) and tested for interactions with alteplase, using ordinal regression in adjusted analyses. We also meta-analyzed all available angiography data from other randomized controlled trials of intravenous thrombolytics. Results— In IST-3, 300 patients had prerandomization angiography (computed tomographic angiography=271 and magnetic resonance angiography=29). On multivariable analysis, more extensive angiographic obstruction and poor collaterals independently predicted poor outcome (P<0.01). We identified no significant interaction between angiography findings and alteplase effect on Oxford Handicap Scale (P≥0.075) in IST-3. In meta-analysis (5 trials of alteplase or desmoteplase, including IST-3, n=591), there was a significantly increased benefit of thrombolytics on outcome (odds ratio>1 indicates benefit) in patients with (odds ratio, 2.07; 95% confidence interval, 1.18–3.64; P=0.011) versus without (odds ratio, 0.88; 95% confidence interval, 0.58–1.35; P=0.566) arterial obstruction (P for interaction 0.017). Conclusions— Intravenous thrombolytics provide benefit to stroke patients with computed tomographic angiography or magnetic resonance angiography evidence of arterial obstruction, but the sample was underpowered to demonstrate significant treatment benefit or harm among patients with apparently patent arteries. Clinical Trial Registration— URL: http://www.isrctn.com. Unique identifier: ISRCTN25765518. PMID:28008093

  1. Memory Restoration Using Computerized Cognitive Training after Pediatric Traumatic Brain Injury: A Review of the Evidence. EBP Briefs. Volume 12, Issue 3

    ERIC Educational Resources Information Center

    Lundine, Jennifer P.

    2017-01-01

    Clinical Question: For children and adolescents with memory impairments after traumatic brain injury (TBI), do computerized cognitive training (CCT) programs used in conjunction with traditional therapy vs. traditional therapy alone lead to memory gains in daily activities? Method: Literature Review. Study Sources: Google Scholar, CINAHL via…

  2. SYN-OP-SYS™: A Computerized Management Information System for Quality Assurance and Risk Management

    PubMed Central

    Thomas, David J.; Weiner, Jayne; Lippincott, Ronald C.

    1985-01-01

    SYN·OP·SYS™ is a computerized management information system for quality assurance and risk management. Computer software for the efficient collection and analysis of “occurrences” and the clinical data associated with these kinds of patient events is described. The system is evaluated according to certain computer design criteria, and the system's implementation is assessed.

  3. Computed tomographic and cross-sectional anatomy of the normal pacu (Colossoma macroponum).

    PubMed

    Carr, Alaina; Weber, E P Scott; Murphy, Chris J; Zwingenberger, Alison

    2014-03-01

    The purpose of this study was to compare and define the normal cross-sectional gross and computed tomographic (CT) anatomy for a species of boney fish to better gain insight into the use of advanced diagnostic imaging for future clinical cases. The pacu (Colossoma macropomum) was used because of its widespread presence in the aquarium trade, its relatively large body size, and its importance in the research and aquaculture settings. Transverse 0.6-mm CT images of three cadaver fish were obtained and compared to corresponding frozen cross sections of the fish. Relevant anatomic structures were identified and labeled at each level; the Hounsfield unit density of major organs was established. The images presented good anatomic detail and provide a reference for future research and clinical investigation.

  4. Feasibility and validity of computerized ambulatory monitoring in stroke patients.

    PubMed

    Johnson, E I; Sibon, I; Renou, P; Rouanet, F; Allard, M; Swendsen, J

    2009-11-10

    Computerized ambulatory monitoring provides real-time assessments of clinical outcomes in natural contexts, and it has been increasingly applied in recent years to investigate symptom expression in a wide range of disorders. The purpose of this study was to examine the feasibility and validity of this data collection strategy with adult stroke patients. Forty-eight individuals (75% of the contacted sample) agreed to participate in the current study and were instructed to complete electronic interviews using a personal digital assistant 5 times per day over a 1-week period. More than 80% of programmed assessments were completed by the sample, and no evidence was found for fatigue effects. Expected patterns of associations were observed among daily life variables, and data collected through ambulatory monitoring were significantly correlated with standard clinic-based measures of similar constructs. Support was found for the feasibility and validity of computerized ambulatory monitoring with stroke patients. The application of these novel methods with stroke patients should provide complementary information that is inaccessible to standard hospital-based assessments and permit increased understanding of the significance of clinical results and test scores for daily life experience.

  5. COMPUTERIZED TRAINING OF CRYOSURGERY – A SYSTEM APPROACH

    PubMed Central

    Keelan, Robert; Yamakawa, Soji; Shimada, Kenji; Rabin, Yoed

    2014-01-01

    The objective of the current study is to provide the foundation for a computerized training platform for cryosurgery. Consistent with clinical practice, the training process targets the correlation of the frozen region contour with the target region shape, using medical imaging and accepted criteria for clinical success. The current study focuses on system design considerations, including a bioheat transfer model, simulation techniques, optimal cryoprobe layout strategy, and a simulation core framework. Two fundamentally different approaches were considered for the development of a cryosurgery simulator, based on a finite-elements (FE) commercial code (ANSYS) and a proprietary finite-difference (FD) code. Results of this study demonstrate that the FE simulator is superior in terms of geometric modeling, while the FD simulator is superior in terms of runtime. Benchmarking results further indicate that the FD simulator is superior in terms of usage of memory resources, pre-processing, parallel processing, and post-processing. It is envisioned that future integration of a human-interface module and clinical data into the proposed computer framework will make computerized training of cryosurgery a practical reality. PMID:23995400

  6. Computerized Measurement of Negative Symptoms in Schizophrenia

    PubMed Central

    Cohen, Alex S.; Alpert, Murray; Nienow, Tasha M.; Dinzeo, Thomas J.; Docherty, Nancy M.

    2008-01-01

    Accurate measurement of negative symptoms is crucial for understanding and treating schizophrenia. However, current measurement strategies are reliant on subjective symptom rating scales which often have psychometric and practical limitations. Computerized analysis of patients’ speech offers a sophisticated and objective means of evaluating negative symptoms. The present study examined the feasibility and validity of using widely-available acoustic and lexical-analytic software to measure flat affect, alogia and anhedonia (via positive emotion). These measures were examined in their relationships to clinically-rated negative symptoms and social functioning. Natural speech samples were collected and analyzed for 14 patients with clinically-rated flat affect, 46 patients without flat affect and 19 healthy controls. The computer-based inflection and speech rate measures significantly discriminated patients with flat affect from controls, and the computer-based measure of alogia and negative emotion significantly discriminated the flat and non-flat patients. Both the computer and clinical measures of positive emotion/anhedonia corresponded to functioning impairments. The computerized method of assessing negative symptoms offered a number of advantages over the symptom scale-based approach. PMID:17920078

  7. Computerization and its contribution to care quality improvement: the nurses' perspective.

    PubMed

    Kagan, Ilya; Fish, Miri; Farkash-Fink, Naomi; Barnoy, Sivia

    2014-12-01

    Despite the widely held belief that the computerization of hospital medical systems contributes to improved patient care management, especially in the context of ordering medications and record keeping, extensive study of the attitudes of medical staff to computerization has found them to be negative. The views of nursing staff have been barely studied and so are unclear. The study reported here investigated the association between nurses' current computer use and skills, the extent of their involvement in quality control and improvement activities on the ward and their perception of the contribution of computerization to improving nursing care. The study was made in the context of a Joint Commission International Accreditation (JCIA) in a large tertiary medical center in Israel. The perception of the role of leadership commitment in the success of a quality initiative was also tested for. Two convenience samples were drawn from 33 clinical wards and units of the medical center. They were questioned at two time points, one before the JCIA and a second after JCIA completion. Of all nurses (N=489), 89 were paired to allow analysis of the study data in a before-and-after design. Thus, this study built three data sets: a pre-JCIA set, a post-JCIA set and a paired sample who completed the questionnaire both before and after JCIA. Data were collected by structured self-administered anonymous questionnaire. After the JCIA the participants ranked the role of leadership in quality improvement, the extent of their own quality control activity, and the contribution of computers to quality improvement higher than before the JCIA. Significant Pearson correlations were found showing that the higher the rating given to quality improvement leadership the more nurses reported quality improvement activities undertaken by them and the higher nurses rated the impact of computerization on the quality of care. In a regression analysis quality improvement leadership and computer use/skills accounted for 30% of the variance in the perceived contribution of computerization to quality improvement. (a) The present study is the first to show a relationship between organizational leadership and computer use by nurses for the purpose of improving clinical care. (b) The nurses' appreciation of the contribution computerization can make to data management and to clinical care quality improvement were both increased by the JCI accreditation process. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Developing an evidence base of best practices for integrating computerized systems into the exam room: a systematic review.

    PubMed

    Patel, Minal R; Vichich, Jennifer; Lang, Ian; Lin, Jessica; Zheng, Kai

    2017-04-01

    The introduction of health information technology systems, electronic health records in particular, is changing the nature of how clinicians interact with patients. Lack of knowledge remains on how best to integrate such systems in the exam room. The purpose of this systematic review was to (1) distill "best" behavioral and communication practices recommended in the literature for clinicians when interacting with patients in the presence of computerized systems during a clinical encounter, (2) weigh the evidence of each recommendation, and (3) rank evidence-based recommendations for electronic health record communication training initiatives for clinicians. We conducted a literature search of 6 databases, resulting in 52 articles included in the analysis. We extracted information such as study setting, research design, sample, findings, and implications. Recommendations were distilled based on consistent support for behavioral and communication practices across studies. Eight behavioral and communication practices received strong support of evidence in the literature and included specific aspects of using computerized systems to facilitate conversation and transparency in the exam room, such as spatial (re)organization of the exam room, maintaining nonverbal communication, and specific techniques that integrate the computerized system into the visit and engage the patient. Four practices, although patient-centered, have received insufficient evidence to date. We developed an evidence base of best practices for clinicians to maintain patient-centered communications in the presence of computerized systems in the exam room. Further work includes development and empirical evaluation of evidence-based guidelines to better integrate computerized systems into clinical care. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  9. Computed tomographic features of apical infection of equine maxillary cheek teeth: a retrospective study of 49 horses.

    PubMed

    Bühler, M; Fürst, A; Lewis, F I; Kummer, M; Ohlerth, S

    2014-07-01

    Computed tomographic (CT) studies evaluating the relevance of individual CT features of apical infection in maxillary cheek teeth are lacking. To study the prevalence and relationship of single CT features in horses with and without clinical evidence of apical infection in maxillary cheek teeth. Retrospective case-control study. Multislice CT scans of the head of 49 horses were evaluated retrospectively. Changes of the infundibulum, pulp, root, lamina dura, periodontal space and alveolar bone in maxillary cheek teeth were recorded. Single CT changes were much more prevalent in the 28 horses with clinical signs. However, infundibular changes and a nondetectable lamina dura were also common in the 21 horses without clinical evidence of apical infection. Computed tomographic abnormalities of the pulp, root, periapical bone and periodontal space and the presence of a tooth fracture were significantly related. Infundibular changes were not associated with other CT signs of apical infection. Although nondetectable lamina dura was the most frequent CT change in all teeth in both studied groups, it was most commonly a solitary feature in otherwise normal teeth. Apical infections, defined as ≥3 CT changes, occurred mainly in the 108/208, 109/209 and 110/210 (Triadan numbers) and were found only in horses with clinical evidence of apical infection, except in one horse without clinical signs that had one affected root. Combined CT changes of the pulp, root, lamina dura, periapical bone and periodontal space and the presence of a tooth fracture appear to be reliable features to diagnose apical infection in maxillary cheek teeth. As a solitary feature, a nondetectable lamina dura should be interpreted cautiously and may even be considered normal due to its minor thickness and/or too low resolution of the imaging modality. © 2013 EVJ Ltd.

  10. Epilepsy Surgery

    MedlinePlus

    ... monitor the brain's activity and detect abnormalities. Single-photon emission computerized tomography (SPECT). The scan image varies ... off anti-seizure drugs after a year or two. By Mayo Clinic Staff . Mayo Clinic Footer Legal ...

  11. Computerized Management Information System in a Community Health Nursing Agency

    PubMed Central

    Simmons, DeLanne A.

    1981-01-01

    The Visiting Nurse Association of Omaha is a nonprofit, voluntary agency providing home health care, preventive care, clinical services, and school health services in an urban-rural setting. It has developed a computerized system which provides for: (1) centralized dictation by service delivery staff; (2) the printing of a uniform clinical, family problem-oriented record; (3) an integrated data base, statistical system, and financial system; and (4) the communication capability to remote stations. (The hardware utilized is an IBM System 34.) Cost effectiveness has been demonstrated by a reduction in cost of visit from $47.02 to $43.79.

  12. Gross, computed tomographic and histological findings in mandibular cheek teeth extracted from horses with clinical signs of pulpitis due to apical infection.

    PubMed

    Casey, M B; Pearson, G R; Perkins, J D; Tremaine, W H

    2015-09-01

    The most prevalent type of equine dental pulpitis due to apical infection is not associated with coronal fractures or periodontal disease. The pathogenesis of this type of pulpitis is not fully understood. Computed tomography (CT) is increasingly used to investigate equine dental disorders. However, gross, tomographic and histopathological changes in equine dental pulpitis have not been compared previously. To compare gross, CT and histological appearances of sectioned mandibular cheek teeth extracted from horses with clinical signs of pulpitis without coronal fractures or periodontal disease. To contribute to understanding the pathogenesis of equine dental pulpitis. Descriptive study using diseased and healthy teeth. Mandibular cheek teeth extracted from horses with clinical signs of pulpitis (cases), and from cadavers with no history of dental disease (controls), were compared using CT in the transverse plane at 1 mm intervals. Teeth were then sectioned transversely, photographed and processed for histopathological examination. Tomographs were compared with corresponding gross and histological sections. Cement, dentine and bone had similar ranges of attenuation (550-2000 Hounsfield Units, HU) in tomographs but could be differentiated from pulp (-400 to 500 HU) and enamel (> 2500 HU). Twelve discrete dental lesions were identified grossly, 10 of which were characterised histologically. Reactive and reparative dentinogenesis and extensive pulpar mineralisation, previously undescribed, were identified. Pulpar oedema, neutrophilic inflammation, cement and enamel defects, and reactive cemental deposition were also observed. The CT and pathological findings corresponded well where there was mineralised tissue deposited, defects in mineralised tissue, or food material in the pulpar area. Pulpar and dentinal necrosis and cement destruction, evident grossly and histologically, did not correspond to CT changes. Computed tomography is useful for identifying deposition and defects of mineralised material but less useful for identifying inflammation and tissue destruction. The equine dentine-pulp complex responds to insult with reactive and reparative changes. © 2014 EVJ Ltd.

  13. Computerized Neuropsychological Assessment Devices: Joint Position Paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology†

    PubMed Central

    Bauer, Russell M.; Iverson, Grant L.; Cernich, Alison N.; Binder, Laurence M.; Ruff, Ronald M.; Naugle, Richard I.

    2012-01-01

    This joint position paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology sets forth our position on appropriate standards and conventions for computerized neuropsychological assessment devices (CNADs). In this paper, we first define CNADs and distinguish them from examiner-administered neuropsychological instruments. We then set forth position statements on eight key issues relevant to the development and use of CNADs in the healthcare setting. These statements address (a) device marketing and performance claims made by developers of CNADs; (b) issues involved in appropriate end-users for administration and interpretation of CNADs; (c) technical (hardware/software/firmware) issues; (d) privacy, data security, identity verification, and testing environment; (e) psychometric development issues, especially reliability, and validity; (f) cultural, experiential, and disability factors affecting examinee interaction with CNADs; (g) use of computerized testing and reporting services; and (h) the need for checks on response validity and effort in the CNAD environment. This paper is intended to provide guidance for test developers and users of CNADs that will promote accurate and appropriate use of computerized tests in a way that maximizes clinical utility and minimizes risks of misuse. The positions taken in this paper are put forth with an eye toward balancing the need to make validated CNADs accessible to otherwise underserved patients with the need to ensure that such tests are developed and utilized competently, appropriately, and with due concern for patient welfare and quality of care. PMID:22382386

  14. Computerized Neuropsychological Assessment Devices: Joint Position Paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology†

    PubMed Central

    Bauer, Russell M.; Iverson, Grant L.; Cernich, Alison N.; Binder, Laurence M.; Ruff, Ronald M.; Naugle, Richard I.

    2013-01-01

    This joint position paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology sets forth our position on appropriate standards and conventions for computerized neuropsychological assessment devices (CNADs). In this paper, we first define CNADs and distinguish them from examiner-administered neuropsychological instruments. We then set forth position statements on eight key issues relevant to the development and use of CNADs in the healthcare setting. These statements address (a) device marketing and performance claims made by developers of CNADs; (b) issues involved in appropriate end-users for administration and interpretation of CNADs; (c) technical (hardware/software/firmware) issues; (d) privacy, data security, identity verification, and testing environment; (e) psychometric development issues, especially reliability and validity; (f) cultural, experiential, and disability factors affecting examinee interaction with CNADs; (g) use of computerized testing and reporting services; and (h) the need for checks on response validity and effort in the CNAD environment. This paper is intended to provide guidance for test developers and users of CNADs that will promote accurate and appropriate use of computerized tests in a way that maximizes clinical utility and minimizes risks of misuse. The positions taken in this paper are put forth with an eye toward balancing the need to make validated CNADs accessible to otherwise underserved patients with the need to ensure that such tests are developed and utilized competently, appropriately, and with due concern for patient welfare and quality of care. PMID:22394228

  15. Tomographic assessment of the spine in children with spondylocostal dysotosis syndrome

    PubMed Central

    Kaissi, Ali Al; Klaushofer, Klaus; Grill, Franz

    2010-01-01

    OBJECTIVE: The aim of this study was to perform a detailed tomographic analysis of the skull base, craniocervical junction, and the entire spine in seven patients with spondylocostal dysostosis syndrome. METHOD: Detailed scanning images have been organized in accordance with the most prominent clinical pathology. The reasons behind plagiocephaly, torticollis, short immobile neck, scoliosis and rigid back have been detected. Radiographic documentation was insufficient modality. RESULTS: Detailed computed tomography scans provided excellent delineation of the osseous abnormality pattern in our patients. CONCLUSION: This article throws light on the most serious osseous manifestations of spondylocostal dysostosis syndrome. PMID:21120293

  16. A Knowledge-Modeling Approach to Integrate Multiple Clinical Practice Guidelines to Provide Evidence-Based Clinical Decision Support for Managing Comorbid Conditions.

    PubMed

    Abidi, Samina

    2017-10-26

    Clinical management of comorbidities is a challenge, especially in a clinical decision support setting, as it requires the safe and efficient reconciliation of multiple disease-specific clinical procedures to formulate a comorbid therapeutic plan that is both effective and safe for the patient. In this paper we pursue the integration of multiple disease-specific Clinical Practice Guidelines (CPG) in order to manage co-morbidities within a computerized Clinical Decision Support System (CDSS). We present a CPG integration framework-termed as COMET (Comorbidity Ontological Modeling & ExecuTion) that manifests a knowledge management approach to model, computerize and integrate multiple CPG to yield a comorbid CPG knowledge model that upon execution can provide evidence-based recommendations for handling comorbid patients. COMET exploits semantic web technologies to achieve (a) CPG knowledge synthesis to translate a paper-based CPG to disease-specific clinical pathways (CP) that include specialized co-morbidity management procedures based on input from domain experts; (b) CPG knowledge modeling to computerize the disease-specific CP using a Comorbidity CPG ontology; (c) CPG knowledge integration by aligning multiple ontologically-modeled CP to develop a unified comorbid CPG knowledge model; and (e) CPG knowledge execution using reasoning engines to derive CPG-mediated recommendations for managing patients with comorbidities. We present a web-accessible COMET CDSS that provides family physicians with CPG-mediated comorbidity decision support to manage Atrial Fibrillation and Chronic Heart Failure. We present our qualitative and quantitative analysis of the knowledge content and usability of COMET CDSS.

  17. Modernizing quality of life assessment: development of a multidimensional computerized adaptive questionnaire for patients with schizophrenia.

    PubMed

    Michel, Pierre; Baumstarck, Karine; Lancon, Christophe; Ghattas, Badih; Loundou, Anderson; Auquier, Pascal; Boyer, Laurent

    2018-04-01

    Quality of life (QoL) is still assessed using paper-based and fixed-length questionnaires, which is one reason why QoL measurements have not been routinely implemented in clinical practice. Providing new QoL measures that combine computer technology with modern measurement theory may enhance their clinical use. The aim of this study was to develop a QoL multidimensional computerized adaptive test (MCAT), the SQoL-MCAT, from the fixed-length SQoL questionnaire for patients with schizophrenia. In this multicentre cross-sectional study, we collected sociodemographic information, clinical characteristics (i.e., duration of illness, the PANSS, and the Calgary Depression Scale), and quality of life (i.e., SQoL). The development of the SQoL-CAT was divided into three stages: (1) multidimensional item response theory (MIRT) analysis, (2) multidimensional computerized adaptive test (MCAT) simulations with analyses of accuracy and precision, and (3) external validity. Five hundred and seventeen patients participated in this study. The MIRT analysis found that all items displayed good fit with the multidimensional graded response model, with satisfactory reliability for each dimension. The SQoL-MCAT was 39% shorter than the fixed-length SQoL questionnaire and had satisfactory accuracy (levels of correlation >0.9) and precision (standard error of measurement <0.55 and root mean square error <0.3). External validity was confirmed via correlations between the SQoL-MCAT dimension scores and symptomatology scores. The SQoL-MCAT is the first computerized adaptive QoL questionnaire for patients with schizophrenia. Tailored for patient characteristics and significantly shorter than the paper-based version, the SQoL-MCAT may improve the feasibility of assessing QoL in clinical practice.

  18. Computed Tomographic Airway Morphology in Chronic Obstructive Pulmonary Disease. Remodeling or Innate Anatomy?

    PubMed

    Diaz, Alejandro A; Estépar, Raul San José; Washko, George R

    2016-01-01

    Computed tomographic measures of central airway morphology have been used in clinical, epidemiologic, and genetic investigation as an inference of the presence and severity of small-airway disease in smokers. Although several association studies have brought us to believe that these computed tomographic measures reflect airway remodeling, a careful review of such data and more recent evidence may reveal underappreciated complexity to these measures and limitations that prompt us to question that belief. This Perspective offers a review of seminal papers and alternative explanations of their data in the light of more recent evidence. The relationships between airway morphology and lung function are observed in subjects who never smoked, implying that native airway structure indeed contributes to lung function; computed tomographic measures of central airways such as wall area, lumen area, and total bronchial area are smaller in smokers with chronic obstructive pulmonary disease versus those without chronic obstructive pulmonary disease; and the airways are smaller as disease severity increases. The observations suggest that (1) native airway morphology likely contributes to the relationships between computed tomographic measures of airways and lung function; and (2) the presence of smaller airways in those with chronic obstructive pulmonary disease versus those without chronic obstructive pulmonary disease as well as their decrease with disease severity suggests that smokers with chronic obstructive pulmonary disease may simply have smaller airways to begin with, which put them at greater risk for the development of smoking-related disease.

  19. Magnetic particle imaging: from proof of principle to preclinical applications

    NASA Astrophysics Data System (ADS)

    Knopp, T.; Gdaniec, N.; Möddel, M.

    2017-07-01

    Tomographic imaging has become a mandatory tool for the diagnosis of a majority of diseases in clinical routine. Since each method has its pros and cons, a variety of them is regularly used in clinics to satisfy all application needs. Magnetic particle imaging (MPI) is a relatively new tomographic imaging technique that images magnetic nanoparticles with a high spatiotemporal resolution in a quantitative way, and in turn is highly suited for vascular and targeted imaging. MPI was introduced in 2005 and now enters the preclinical research phase, where medical researchers get access to this new technology and exploit its potential under physiological conditions. Within this paper, we review the development of MPI since its introduction in 2005. Besides an in-depth description of the basic principles, we provide detailed discussions on imaging sequences, reconstruction algorithms, scanner instrumentation and potential medical applications.

  20. Computerized NCLEX-RN and NCLEX-PN preparation programs. Comparative review, 1997.

    PubMed

    Riner, M E; Mueller, C; Ihrke, B; Smolen, R A; Wilson, M; Richardson, V; Stone, C; Zwirn, E E

    1997-01-01

    The computerized test taking market continues to expand to meet the needs of nursing students studying to prepare for the NCLEX-RN and the NCLEX-PN. In addition, currently registered nurses may choose to use these software programs to review clinical knowledge in areas in which they are not currently practicing. This article reviewed software designed for personal use, review books with complete disks, on-site institutional testing and consultation, and school of nursing LANs. The costs of software for personal use is priced reasonably and provides flexibility for students to use as their schedule permits. The cost of institutional licenses is moderate and most programs provide multiple on-site use rights. The marketplace has responded to the computerized NCLEX testing now in place nationally. As new formats are developed and new uses identified, nursing faculty and students can expect to see an expanded use of computerized testing.

  1. Meta-cognitive skills training enhances computerized cognitive remediation outcomes among individuals with first-episode psychosis.

    PubMed

    Breitborde, Nicholas J K; Woolverton, Cindy; Dawson, Spencer C; Bismark, Andrew; Bell, Emily K; Bathgate, Christina J; Norman, Kaila

    2017-06-01

    Meta-cognitive skills training (MST) is a frequent component of cognitive remediation programmes for individuals with psychosis. However, no study has investigated whether incorporating such activities produces increased clinical benefits compared with computerized cognitive remediation alone. Individuals with first-episode psychosis who completed computerized cognitive remediation with concurrent meta-cognitive skills training (CCR + MST) were compared with a historical control group who received computerized cognitive remediation alone (CCR) and did not differ from the CCR + MST group with regard to pre-intervention cognition, diagnosis, age, duration of psychotic illness or sex. Participants completed assessments of cognition and real-world functioning before and after 6 months of treatment. Individual receiving CCR + MST experience greater gains in cognition and real-world functioning than individuals who received CCR. MST may be an important component within cognitive remediation programmes for first-episode psychosis. © 2015 Wiley Publishing Asia Pty Ltd.

  2. Using Human Factors Methods to Design a New Interface for an Electronic Medical Record

    PubMed Central

    Saleem, Jason J.; Patterson, Emily S.; Militello, Laura; Asch, Steven M.; Doebbeling, Bradley N.; Render, Marta L.

    2007-01-01

    The Veterans Health Administration (VHA) is a leader in development and use of electronic patient records and clinical decision support. The VHA is currently reengineering a somewhat dated platform for its Computerized Patient Record System (CPRS). This process affords a unique opportunity to implement major changes to the current design and function of the system. We report on two human factors studies designed to provide input and guidance during this reengineering process. One study involved a card sort to better understand how providers tend to cognitively organize clinical data, and how that understanding can help guide interface design. The other involved a simulation to assess the impact of redesign modifications on computerized clinical reminders, a form of clinical decision support in the CPRS, on the learnability of the system for first-time users. PMID:18693914

  3. Evaluation of Psychology Clinicians' Attitudes towards Computerized Cognitive Behavior Therapy, for Use in Their Future Clinical Practice, with Regard to Treating Those Suffering from Anxiety and Depression

    ERIC Educational Resources Information Center

    Dunne, Nivek

    2017-01-01

    Computerized Cognitive Behavioural Therapy (CCBT) is an empirically supported therapeutic modality used in the treatment of anxiety and depression. It is an important area of research considering there is much research lacking in this area, especially regarding trainee and qualified psychology clinicians' attitudes which are informative in terms…

  4. Use of radiography, computed tomography and magnetic resonance imaging for evaluation of navicular syndrome in the horse.

    PubMed

    Widmer, W R; Buckwalter, K A; Fessler, J F; Hill, M A; VanSickle, D C; Ivancevich, S

    2000-01-01

    Radiographic evaluation of navicular syndrome is problematic because of its inconsistent correlation with clinical signs. Scintigraphy often yields false positive and false negative results and diagnostic ultrasound is of limited value. Therefore, we assessed the use of computed tomography and magnetic resonance imaging in a horse with clinical and radiographic signs of navicular syndrome. Cadaver specimens were examined with spiral computed tomographic and high-field magnetic resonance scanners and images were correlated with pathologic findings. Radiographic changes consisted of bony remodeling, which included altered synovial fossae, increased medullary opacity, cyst formation and shape change. These osseous changes were more striking and more numerous on computed tomographic and magnetic resonance images. They were most clearly defined with computed tomography. Many osseous changes seen with computed tomography and magnetic resonance imaging were not radiographically evident. Histologically confirmed soft tissue alterations of the deep digital flexor tendon, impar ligament and marrow were identified with magnetic resonance imaging, but not with conventional radiography. Because of their multiplanar capability and tomographic nature, computed tomography and magnetic resonance imaging surpass conventional radiography for navicular imaging, facilitating earlier, more accurate diagnosis. Current advances in imaging technology should make these imaging modalities available to equine practitioners in the future.

  5. Computerized intrapartum electronic fetal monitoring: analysis of the decision to deliver for fetal distress.

    PubMed

    Georgieva, Antoniya; Payne, Stephen J; Moulden, Mary; Redman, Christopher W G

    2011-01-01

    We applied computerized methods to assess the Electronic Fetal Monitoring (EFM) in labor. We analyzed retrospectively the last hour of EFM for 1,370 babies, delivered by emergency Cesarean sections before the onset of pushing (data collected at the John Radcliffe Hospital, Oxford, UK). There were two cohorts according to the reason for intervention: (a) fetal distress, n(1) = 524 and (b) failure to progress and/or malpresentation, n(2) = 846. The cohorts were compared in terms of classical EFM features (baseline, decelerations, variability and accelerations), computed by a dedicated Oxford system for automated analysis--OxSys. In addition, OxSys was employed to simulate current clinical guidelines for the classification of fetal monitoring, i.e. providing in real time a three-tier grading system of the EFM (normal, indeterminate, or abnormal). The computerized features and the simulated guidelines corresponded well to the clinical management and to the actual labor outcome (measured by umbilical arterial pH).

  6. Effects of computerized clinical decision support systems on practitioner performance and patient outcomes: methods of a decision-maker-researcher partnership systematic review.

    PubMed

    Haynes, R Brian; Wilczynski, Nancy L

    2010-02-05

    Computerized clinical decision support systems are information technology-based systems designed to improve clinical decision-making. As with any healthcare intervention with claims to improve process of care or patient outcomes, decision support systems should be rigorously evaluated before widespread dissemination into clinical practice. Engaging healthcare providers and managers in the review process may facilitate knowledge translation and uptake. The objective of this research was to form a partnership of healthcare providers, managers, and researchers to review randomized controlled trials assessing the effects of computerized decision support for six clinical application areas: primary preventive care, therapeutic drug monitoring and dosing, drug prescribing, chronic disease management, diagnostic test ordering and interpretation, and acute care management; and to identify study characteristics that predict benefit. The review was undertaken by the Health Information Research Unit, McMaster University, in partnership with Hamilton Health Sciences, the Hamilton, Niagara, Haldimand, and Brant Local Health Integration Network, and pertinent healthcare service teams. Following agreement on information needs and interests with decision-makers, our earlier systematic review was updated by searching Medline, EMBASE, EBM Review databases, and Inspec, and reviewing reference lists through 6 January 2010. Data extraction items were expanded according to input from decision-makers. Authors of primary studies were contacted to confirm data and to provide additional information. Eligible trials were organized according to clinical area of application. We included randomized controlled trials that evaluated the effect on practitioner performance or patient outcomes of patient care provided with a computerized clinical decision support system compared with patient care without such a system. Data will be summarized using descriptive summary measures, including proportions for categorical variables and means for continuous variables. Univariable and multivariable logistic regression models will be used to investigate associations between outcomes of interest and study specific covariates. When reporting results from individual studies, we will cite the measures of association and p-values reported in the studies. If appropriate for groups of studies with similar features, we will conduct meta-analyses. A decision-maker-researcher partnership provides a model for systematic reviews that may foster knowledge translation and uptake.

  7. Health technology assessment review: Computerized glucose regulation in the intensive care unit - how to create artificial control

    PubMed Central

    2009-01-01

    Current care guidelines recommend glucose control (GC) in critically ill patients. To achieve GC, many ICUs have implemented a (nurse-based) protocol on paper. However, such protocols are often complex, time-consuming, and can cause iatrogenic hypoglycemia. Computerized glucose regulation protocols may improve patient safety, efficiency, and nurse compliance. Such computerized clinical decision support systems (Cuss) use more complex logic to provide an insulin infusion rate based on previous blood glucose levels and other parameters. A computerized CDSS for glucose control has the potential to reduce overall workload, reduce the chance of human cognitive failure, and improve glucose control. Several computer-assisted glucose regulation programs have been published recently. In order of increasing complexity, the three main types of algorithms used are computerized flowcharts, Proportional-Integral-Derivative (PID), and Model Predictive Control (MPC). PID is essentially a closed-loop feedback system, whereas MPC models the behavior of glucose and insulin in ICU patients. Although the best approach has not yet been determined, it should be noted that PID controllers are generally thought to be more robust than MPC systems. The computerized Cuss that are most likely to emerge are those that are fully a part of the routine workflow, use patient-specific characteristics and apply variable sampling intervals. PMID:19849827

  8. NECTAR—A fission neutron radiography and tomography facility

    NASA Astrophysics Data System (ADS)

    Bücherl, T.; Lierse von Gostomski, Ch.; Breitkreutz, H.; Jungwirth, M.; Wagner, F. M.

    2011-09-01

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/ D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  9. An alternative method in mandibular fracture treatment: bone graft use instead of a plate.

    PubMed

    Alagöz, Murat Sahin; Uysal, Ahmet Cagri; Sensoz, Omer

    2008-03-01

    In the treatment of the mandibular fractures, one of the main principles is to use the least amount of foreign material. We present an alternative technique that the bone grafts harvested from the fracture borders or from the iliac crest were used instead of plates and the fixation was done with screws. In the study including 24 mandible fractures, the bone grafts harvested from the fracture borders were used in the 10 favorable fractures and the bone grafts harvested from the iliac crest were used in the 14 unfavorable fractures. In the combined mandible fractures, four fractures were fixated with titanium plates and the other side with the bone graft. The patients, who were followed up for 12 to 20 months, were evaluated with macroscopic occlusion, panoramic graphs, and three-dimensional computerized tomographs. The advantage of this technique of fixation with the autogenous tissue is reduced infection rates and reduced operation costs. In the pediatric patients, the second session operation of plate removal is not necessary.

  10. Documentation of Nursing Practice Using a Computerized Medical Information System

    PubMed Central

    Romano, Carol

    1981-01-01

    This paper discusses a definition of the content of the computerized nursing data base developed by the Nursing Department for the Clinical Center Medical Information System at the National Institutes of Health in Bethesda, Maryland. The author describes the theoretical framework for the content and presents a model to describe the organization of the nursing data components in relation to the process of nursing care delivery. Nursing documentation requirements of Nurse Practice Acts, American Nurses Association Standards of Practice and the Joint Commission on Accreditation of Hospitals are also addressed as they relate to this data base. The advantages and disadvantages of such an approach to computerized documentation are discussed.

  11. Effectiveness of computerized cognitive rehabilitation training on symptomatological, neuropsychological and work function in patients with schizophrenia.

    PubMed

    Lee, Woo Kyeong

    2013-06-01

    There has been plenty of interest in cognitive rehabilitation for schizophrenia here in Korea since the year 2000. But the efficacy studies of cognitive remediation intervention are still deficient. The primary purpose of this study was to develop a computer-assisted cognitive remediation program and conduct a clinical trial in a group of schizophrenic patients. Sixty patients with schizophrenia were randomly assigned to a computerized cognitive rehabilitation (Cog-trainer) group plus usual rehabilitation (UR) or to a usual rehabilitation (UR) group only. Clinical, neuropsychological and functional outcome variables were assessed at baseline and after intervention. The Cog-trainer group received 20 sessions of computerized cognitive remediation training over 3 months. This training program consists of 10 units, with each unit being divided into three stages: (i) practice; (ii) application; and (iii) advanced. Compared to the UR group, the Cog-trainer exhibited a significant improvement in attention, concentration and working memory. The Cog-trainer group also showed improvement in the work quality subscale of the work behavior inventory. However, there were no significant benefits of computerized cognitive remediation where symptoms were concerned. These results indicate that computerized cognitive rehabilitation training can contribute to an improvement in the cognitive function of people with schizophrenia. The changes in cognitive outcomes can also contribute to improvement in job functioning. Further study of generalization to other functional outcome measures will be necessary. Long-term follow-up studies are needed to confirm the maintenance of such improvements. Copyright © 2013 Wiley Publishing Asia Pty Ltd.

  12. Mini-Stroke vs. Regular Stroke: What's the Difference?

    MedlinePlus

    ... may need various diagnostic tests, such as a magnetic resonance imaging (MRI) scan or a computerized tomography ( ... org," "Mayo Clinic Healthy Living," and the triple-shield Mayo Clinic logo are trademarks of Mayo Foundation ...

  13. Application of gray level mapping in computed tomographic colonography: a pilot study to compare with traditional surface rendering method for identification and differentiation of endoluminal lesions

    PubMed Central

    Chen, Lih-Shyang; Hsu, Ta-Wen; Chang, Shu-Han; Lin, Chih-Wen; Chen, Yu-Ruei; Hsieh, Chin-Chiang; Han, Shu-Chen; Chang, Ku-Yaw; Hou, Chun-Ju

    2017-01-01

    Objective: In traditional surface rendering (SR) computed tomographic endoscopy, only the shape of endoluminal lesion is depicted without gray-level information unless the volume rendering technique is used. However, volume rendering technique is relatively slow and complex in terms of computation time and parameter setting. We use computed tomographic colonography (CTC) images as examples and report a new visualization technique by three-dimensional gray level mapping (GM) to better identify and differentiate endoluminal lesions. Methods: There are 33 various endoluminal cases from 30 patients evaluated in this clinical study. These cases were segmented using gray-level threshold. The marching cube algorithm was used to detect isosurfaces in volumetric data sets. GM is applied using the surface gray level of CTC. Radiologists conducted the clinical evaluation of the SR and GM images. The Wilcoxon signed-rank test was used for data analysis. Results: Clinical evaluation confirms GM is significantly superior to SR in terms of gray-level pattern and spatial shape presentation of endoluminal cases (p < 0.01) and improves the confidence of identification and clinical classification of endoluminal lesions significantly (p < 0.01). The specificity and diagnostic accuracy of GM is significantly better than those of SR in diagnostic performance evaluation (p < 0.01). Conclusion: GM can reduce confusion in three-dimensional CTC and well correlate CTC with sectional images by the location as well as gray-level value. Hence, GM increases identification and differentiation of endoluminal lesions, and facilitates diagnostic process. Advances in knowledge: GM significantly improves the traditional SR method by providing reliable gray-level information for the surface points and is helpful in identification and differentiation of endoluminal lesions according to their shape and density. PMID:27925483

  14. A novel flexible clinical multiphoton tomograph for early melanoma detection, skin analysis, testing of anti-age products, and in situ nanoparticle tracking

    NASA Astrophysics Data System (ADS)

    Weinigel, Martin; Breunig, Hans Georg; Gregory, Axel; Fischer, Peter; Kellner-Höfer, Marcel; Bückle, Rainer; König, Karsten

    2010-02-01

    High-resolution 3D microscopy based on multiphoton induced autofluorescence and second harmonic generation have been introduced in 1990. 13 years later, CE-marked clinical multiphoton systems for 3D imaging of human skin with subcellular resolution have first been launched by JenLab company with the tomography DermaInspect®. This year, the second generation of clinical multiphoton tomographs was introduced. The novel multiphoton tomograph MPTflex, equipped with a flexible articulated optical arm, provides an increased flexibility and accessibility especially for clinical and cosmetical examinations. Improved image quality and signal to noise ratio (SNR) are achieved by a very short source-drain spacing, by larger active areas of the detectors and by single photon counting (SPC) technology. Shorter image acquisition time due to improved image quality reduces artifacts and simplifies the operation of the system. The compact folded optical design and the light-weight structure of the optical head eases the handling. Dual channel detectors enable to distinguish between intratissue elastic fibers and collagenous structures simultaneously. Through the use of piezo-driven optics a stack of optical cross-sections (optical sectioning) can be acquired and 3D imaging can be performed. The multiphoton excitation of biomolecules like NAD(P)H, flavins, porphyrins, elastin, and melanin is done by picojoule femtosecond laser pulses from an tunable turn-key femtosescond near infrared laser system. The ability for rapid high-quality image acquisition, the user-friendly operation of the system and the compact and flexible design qualifies this system to be used for melanoma detection, diagnostics of dermatological disorders, cosmetic research and skin aging measurements as well as in situ drug monitoring and animal research.

  15. Views on health information sharing and privacy from primary care practices using electronic medical records.

    PubMed

    Perera, Gihan; Holbrook, Anne; Thabane, Lehana; Foster, Gary; Willison, Donald J

    2011-02-01

    To determine how patients and physicians balance the perceived benefits and harms of sharing electronic health data for patient care and for secondary purposes. Before-after survey of patients and providers in practices using electronic medical records (EMRs) enrolled in a clinical trial in Ontario, Canada. Outcomes were measured using the Health Information Privacy Questionnaire (HIPQ) at baseline and end of study. Thirteen questions in 4 general domains investigated attitudes towards the privacy of EMRs, outsider's use of patient's health information, the sharing of patient's information within the health care system, and the overall perception of benefits versus harms of computerization in health care. 511 patients (mean age 60.3 years, 49.6% female) and 46 physicians (mean age 47.2 years, 37.0% female) participated. Most (>90%) supported the computerized sharing of the patient's health records among their health care professionals and to provide clinical advice. Fewer agreed that the patient's de-identified information should be shared outside of the health care circle (<70%). Only a minority of either group supported the notion that computerized records can be keep more private than paper records (38-50%). Overall, a majority (58% patients, 70% physicians) believed that the benefits of computerization were greater than the risks of confidentiality loss. This was especially true for patients who were frequent computer users. While these primary care physicians and their patients valued the clinical features of EMRs, a substantial minority have concerns about the secondary use of de-identified information. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  16. Tomographic findings of acute pulmonary toxoplasmosis in immunocompetent patients.

    PubMed

    de Souza Giassi, Karina; Costa, Andre Nathan; Apanavicius, Andre; Teixeira, Fernando Bin; Fernandes, Caio Julio Cesar; Helito, Alfredo Salim; Kairalla, Ronaldo Adib

    2014-11-25

    Toxoplasmosis is one of the most common human zoonosis, and is generally benign in most of the individuals. Pulmonary involvement is common in immunocompromised subjects, but very rare in immunocompetents and there are scarce reports of tomographic findings in the literature. The aim of the study is to describe three immunocompetent patients diagnosed with acute pulmonary toxoplasmosis and their respective thoracic tomographic findings. Acute toxoplasmosis was diagnosed according to the results of serological tests suggestive of recent primary infection and the absence of an alternative etiology. From 2009 to 2013, three patients were diagnosed with acute respiratory failure secondary to acute toxoplasmosis. The patients were two female and one male, and were 38, 56 and 36 years old. Similarly they presented a two-week febrile illness and progressive dyspnea before admission. Laboratory tests demonstrated lymphocytosis, slight changes in liver enzymes and high inflammatory markers. Tomographic findings were bilateral smooth septal and peribronchovascular thickening (100%), ground-glass opacities (100%), atelectasis (33%), random nodules (33%), lymph node enlargement (33%) and pleural effusion (66%). All the patients improved their symptoms after treatment, and complete resolution of tomographic findings were found in the followup. These cases provide a unique description of the presentation and evolution of pulmonary tomographic manifestations of toxoplasmosis in immunocompetent patients. Toxoplasma pneumonia manifests with fever, dyspnea and a non-productive cough that may result in respiratory failure. In animal models, changes were described as interstitial pneumonitis with focal infiltrates of neutrophils that can finally evolve into a pattern of diffuse alveolar damage with focal necrosis. The tomographic findings are characterized as ground glass opacities, smooth septal and marked peribronchovascular thickening; and may mimic pulmonary congestion, lymphangitis, atypical pneumonia and pneumocystosis. This is the largest series of CT findings of acute toxoplasmosis in immunocompetent hosts, and the diagnosis should be considered as patients that present with acute respiratory failure in the context of a subacute febrile illness with bilateral and diffuse interstitial infiltrates with marked peribronchovascular thickening. If promptly treated, pulmonary toxoplasmosis can result in complete clinical and radiological recovery in immunocompetent hosts.

  17. Monitoring wound healing by multiphoton tomography/endoscopy

    NASA Astrophysics Data System (ADS)

    König, Karsten; Weinigel, Martin; Bückle, Rainer; Kaatz, Martin; Hipler, Christina; Zens, Katharina; Schneider, Stefan W.; Huck, Volker

    2015-02-01

    Certified clinical multiphoton tomographs are employed to perform rapid label-free high-resolution in vivo histology. Novel tomographs include a flexible 360° scan head attached to a mechano-optical arm for autofluorescence and SHG imaging as well as rigid two-photon GRIN microendoscope. Mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen can be imaged with submicron resolution in human skin. The system was employed to study the healing of chronic wounds (venous leg ulcer) and acute wounds (curettage of actinic or seborrheic keratosis) on a subcellular level. Furthermore, a flexible sterile foil as interface between wound and focusing optic was tested.

  18. Biopsy: Types of Biopsy Procedures Used to Diagnose Cancer

    MedlinePlus

    ... procedure — such as X-ray, computerized tomography (CT), magnetic resonance imaging (MRI) or ultrasound — with a needle ... org," "Mayo Clinic Healthy Living," and the triple-shield Mayo Clinic logo are trademarks of Mayo Foundation ...

  19. Computerized clinical decision support for prescribing: provision does not guarantee uptake

    PubMed Central

    Moxey, Annette; Robertson, Jane; Newby, David; Hains, Isla; Williamson, Margaret; Pearson, Sallie-Anne

    2010-01-01

    There is wide variability in the use and adoption of recommendations generated by computerized clinical decision support systems (CDSSs) despite the benefits they may bring to clinical practice. We conducted a systematic review to explore the barriers to, and facilitators of, CDSS uptake by physicians to guide prescribing decisions. We identified 58 studies by searching electronic databases (1990–2007). Factors impacting on CDSS use included: the availability of hardware, technical support and training; integration of the system into workflows; and the relevance and timeliness of the clinical messages. Further, systems that were endorsed by colleagues, minimized perceived threats to professional autonomy, and did not compromise doctor-patient interactions were accepted by users. Despite advances in technology and CDSS sophistication, most factors were consistently reported over time and across ambulatory and institutional settings. Such factors must be addressed when deploying CDSSs so that improvements in uptake, practice and patient outcomes may be achieved. PMID:20064798

  20. Management of queues in out-patient departments: the use of computer simulation.

    PubMed

    Aharonson-Daniel, L; Paul, R J; Hedley, A J

    1996-01-01

    Notes that patients attending public outpatient departments in Hong Kong spend a long time waiting for a short consultation, that clinics are congested and that both staff and patients are dissatisfied. Points out that experimentation of management changes in a busy clinical environment can be both expensive and difficult. Demonstrates computerized simulation modelling as a potential tool for clarifying processes occurring within such systems, improving clinic operation by suggesting possible answers to problems identified and evaluating the solutions, without interfering with the clinic routine. Adds that solutions can be implemented after they had proved to be successful on the model. Demonstrates some ways in which managers in health care facilities can benefit from the use of computerized simulation modelling. Specifically, shows the effect of changing the duration of consultation and the effect of the application of an appointment system on patients' waiting time.

  1. Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis.

    PubMed

    Teymouri, Jessica; Hullar, Timothy E; Holden, Timothy A; Chole, Richard A

    2011-08-01

    To determine the efficacy of clinical computed tomographic (CT) imaging to verify postoperative electrode array placement in cochlear implant (CI) patients. Nine fresh cadaver heads underwent clinical CT scanning, followed by bilateral CI insertion and postoperative clinical CT scanning. Temporal bones were removed, trimmed, and scanned using micro-CT. Specimens were then dehydrated, embedded in either methyl methacrylate or LR White resin, and sectioned with a diamond wafering saw. Histology sections were examined by 3 blinded observers to determine the position of individual electrodes relative to soft tissue structures within the cochlea. Electrodes were judged to be within the scala tympani, scala vestibuli, or in an intermediate position between scalae. The position of the array could be estimated accurately from clinical CT scans in all specimens using micro-CT and histology as a criterion standard. Verification using micro-CT yielded 97% agreement, and histologic analysis revealed 95% agreement with clinical CT results. A composite, 3-dimensional image derived from a patient's preoperative and postoperative CT images using a clinical scanner accurately estimates the position of the electrode array as determined by micro-CT imaging and histologic analyses. Information obtained using the CT method provides valuable insight into numerous variables of interest to patient performance such as surgical technique, array design, and processor programming and troubleshooting.

  2. Computed tomographic contrast tenography of the digital flexor tendon sheath of the equine hindlimb.

    PubMed

    Agass, Rachel; Dixon, Jonathon; Fraser, Barny

    2018-05-01

    Pre-surgical investigation of digital flexor tendon sheath pathology remains challenging with current standard imaging techniques. The aim of this prospective, anatomical, pilot study was to describe the anatomy of the equine hind limb digital flexor tendon sheath using a combination of computed tomography (CT) and computed tomographic contrast tenography in clinically normal cadaver limbs. Ten pairs of hind limbs with no external abnormalities were examined from the level of the tarsometatarsal joint distally. Limbs initially underwent non-contrast CT examination using 120 kVp, 300 mAs, and 1.5 mm slice thickness. Sixty millilitres of ioversol iodinated contrast media and saline (final concentration 100 mg/ml) were injected using a basilar sesamoidean approach. The computed tomographic contrast tenography examination was then repeated, before dissection of the specimens to compare gross and imaging findings. The combined CT and computed tomographic contrast tenography examinations provided excellent anatomical detail of intra-thecal structures. The borders of the superficial and deep digital flexor tendons, and the manica flexoria were consistently identifiable in all limbs. Detailed anatomy including that of the mesotenons, two of which are previously undescribed, and the plantar annular ligament were also consistently identifiable. Dissection of all 10 pairs of limbs revealed there to be no pathology, in accordance with the imaging findings. In conclusion, the combination of CT and computed tomographic contrast tenography may be useful adjunctive diagnostic techniques to define digital flexor tendon sheath pathology prior to surgical exploration in horses. © 2017 American College of Veterinary Radiology.

  3. A randomized controlled trial of the Cool Teens CD-ROM computerized program for adolescent anxiety.

    PubMed

    Wuthrich, Viviana M; Rapee, Ronald M; Cunningham, Michael J; Lyneham, Heidi J; Hudson, Jennifer L; Schniering, Carolyn A

    2012-03-01

    Computerized cognitive behavioral interventions for anxiety disorders in adults have been shown to be efficacious, but limited data are available on the use of computerized interventions with young persons. Adolescents in particular are difficult to engage in treatment and may be especially suited to computerized technologies. This paper describes the results of a small randomized controlled trial of the Cool Teens program for adolescent anxiety, and examines potential barriers to treatment and user preferences of computerized technology in this population. Forty-three adolescents with a primary diagnosis of anxiety were randomly allocated to the Cool Teens program, a 12-week computerized cognitive-behavioral therapy program for anxiety management, or a 12-week wait list. Effects on symptoms, negative thoughts, and life interference were assessed at post-treatment and 3-month follow-up, based on diagnosis as well as self and maternal report. Using mixed-model analyses, at post-treatment and follow-up assessments, adolescents in the Cool Teens condition, compared with those on the wait list, were found to have significant reductions in the total number of anxiety disorders, the severity of the primary anxiety disorder, and the average severity for all disorders. These results were matched by significant reductions in mother and child questionnaire reports of anxiety, internalizing symptoms, automatic thoughts, and life interference. Further few barriers to treatment were found, and user preferences indicated that the computerized treatment was well suited to adolescents with anxiety. The Cool Teens program is efficacious for treatment of adolescent anxiety. Clinical trial registration information-A randomized controlled trial of the Cool Teens computerized program for anxious adolescents compared with waist list; http://www.anzctr.org.au; ACTRN12611000508976. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  4. Clinical applications of computerized thermography

    NASA Technical Reports Server (NTRS)

    Anbar, Michael

    1988-01-01

    Computerized or digital, thermography is a rapidly growing diagnostic imaging modality. It has superseded contact thermography and analog imaging thermography which do not allow effective quantization. Medical applications of digital thermography can be classified in two groups: static and dynamic imaging. They can also be classified into macro thermography (resolution greater than 1 mm) and micro thermography (resolution less than 100 microns). Both modalities allow a thermal resolution of 0.1 C. The diagnostic power of images produced by any of these modalities can be augmented by the use of digital image enhancement and image recognition procedures. Computerized thermography has been applied in neurology, cardiovascular and plastic surgery, rehabilitation and sports medicine, psychiatry, dermatology and ophthalmology. Examples of these applications are shown and their scope and limitations are discussed.

  5. Computerized measures of finger tapping: effects of hand dominance, age, and sex.

    PubMed

    Hubel, Kerry A; Reed, Bruce; Yund, E William; Herron, Timothy J; Woods, David L

    2013-06-01

    Computerized measures of digit tapping rate were obtained over 3 successive, 10-sec. periods in the right and left index fingers, from a community sample of 1,519 participants (ages 18 to 65 years; 607 men, 912 women). Differences between the dominant and non-dominant hands were found for tapping rate, movement initiation, and button down times, and the decline in tapping rate over the successive, 10-sec. periods. Declines were found in tapping rate in older participants in association with increased intertap variability. Men had higher tapping rates than women in all age ranges. The computerized finger tapping test is an efficient and precise measure of tapping speed and kinetics of potential utility in research and clinical studies of motor performance.

  6. A Multisite, Randomized Controlled Clinical Trial of Computerized Cognitive Remediation Therapy for Schizophrenia.

    PubMed

    Gomar, Jesús J; Valls, Elia; Radua, Joaquim; Mareca, Celia; Tristany, Josep; del Olmo, Francisco; Rebolleda-Gil, Carlos; Jañez-Álvarez, María; de Álvaro, Francisco J; Ovejero, María R; Llorente, Ana; Teixidó, Cristina; Donaire, Ana M; García-Laredo, Eduardo; Lazcanoiturburu, Andrea; Granell, Luis; Mozo, Cristina de Pablo; Pérez-Hernández, Mónica; Moreno-Alcázar, Ana; Pomarol-Clotet, Edith; McKenna, Peter J

    2015-11-01

    The effectiveness of cognitive remediation therapy (CRT) for the neuropsychological deficits seen in schizophrenia is supported by meta-analysis. However, a recent methodologically rigorous trial had negative findings. In this study, 130 chronic schizophrenic patients were randomly assigned to computerized CRT, an active computerized control condition (CC) or treatment as usual (TAU). Primary outcome measures were 2 ecologically valid batteries of executive function and memory, rated under blind conditions; other executive and memory tests and a measure of overall cognitive function were also employed. Carer ratings of executive and memory failures in daily life were obtained before and after treatment. Computerized CRT was found to produce improvement on the training tasks, but this did not transfer to gains on the primary outcome measures and most other neuropsychological tests in comparison to either CC or TAU conditions. Nor did the intervention result in benefits on carer ratings of daily life cognitive failures. According to this study, computerized CRT is not effective in schizophrenia. The use of both active and passive CCs suggests that nature of the control group is not an important factor influencing results. © The Author 2015. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center.

  7. [Is the ICU staff satisfied with the computerized physician order entry? A cross-sectional survey study].

    PubMed

    Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto

    2014-01-01

    To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, p<0.001); satisfaction decreased with age (p<0.001). Physicians scored lower concerning the potential of the computerized physician order entry for improving patient safety (5.45±2.20 versus 8.09±2.21, p<0.001) and the ease of using the computerized physician order entry (3.83±1.88 versus 6.44±2.31, p<0.001). The characteristics independently associated with satisfaction were the system's user-friendliness, accuracy, capacity to provide clear information, and fast response time. Six months after its implementation, healthcare workers were satisfied, albeit not entirely, with the computerized physician order entry. The overall users' satisfaction with computerized physician order entry was lower among physicians compared to other healthcare professionals. The factors associated with satisfaction included the belief that digitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame.

  8. Redesign of a computerized clinical reminder for colorectal cancer screening: a human-computer interaction evaluation

    PubMed Central

    2011-01-01

    Background Based on barriers to the use of computerized clinical decision support (CDS) learned in an earlier field study, we prototyped design enhancements to the Veterans Health Administration's (VHA's) colorectal cancer (CRC) screening clinical reminder to compare against the VHA's current CRC reminder. Methods In a controlled simulation experiment, 12 primary care providers (PCPs) used prototypes of the current and redesigned CRC screening reminder in a within-subject comparison. Quantitative measurements were based on a usability survey, workload assessment instrument, and workflow integration survey. We also collected qualitative data on both designs. Results Design enhancements to the VHA's existing CRC screening clinical reminder positively impacted aspects of usability and workflow integration but not workload. The qualitative analysis revealed broad support across participants for the design enhancements with specific suggestions for improving the reminder further. Conclusions This study demonstrates the value of a human-computer interaction evaluation in informing the redesign of information tools to foster uptake, integration into workflow, and use in clinical practice. PMID:22126324

  9. Clinical evaluation of the WOMAC 3.0 OA Index in numeric rating scale format using a computerized touch screen version.

    PubMed

    Theiler, R; Spielberger, J; Bischoff, H A; Bellamy, N; Huber, J; Kroesen, S

    2002-06-01

    The Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index is a previously described self-administered questionnaire covering three domains: pain, stiffness and function. It has been validated in patients with osteoarthritis (OA) of the hip or knee in a paper-based format. To validate the WOMAC 3.0 using a numerical rating scale in a computerized touch screen format allowing immediate evaluation of the questionnaire. In the computed version cartoons, written and audio instruments were included in order facilitate application. Fifty patients, demographically balanced, with radiographically proven primary hip or knee OA completed the classical paper and the new computerized WOMAC version. Subjects were randomized either to paper format or computerized format first to balance possible order effects. The intra-class correlation coefficients for pain, stiffness and function values were 0.915, 0.745 and 0.940, respectively. The Spearman correlation coefficients for pain, stiffness and function were 0.88, 0.77 and 0.87, respectively. These data indicate that the computerized WOMAC OA index 3.0 is comparable to the paper WOMAC in all three dimensions. The computerized version would allow physicians to get an immediate result and if present a direct comparison with a previous exam. Copyright 2002 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.

  10. Cognitive Function Before and After Left Heart Catheterization.

    PubMed

    Scott, David A; Evered, Lisbeth; Maruff, Paul; MacIsaac, Andrew; Maher, Sarah; Silbert, Brendan S

    2018-03-10

    Hospital procedures have been associated with cognitive change in older patients. This study aimed to document the prevalence of mild cognitive impairment in individuals undergoing left heart catheterization (LHC) before the procedure and the incidence of cognitive decline to 3 months afterwards. We conducted a prospective, observational, clinical investigation of elderly participants undergoing elective LHC. Cognition was assessed using a battery of written tests and a computerized cognitive battery before the LHC and then at 3 months afterwards. The computerized tests were also administered at 24 hours (or discharge) and 7 days after LHC. A control group of 51 community participants was recruited to calculate cognitive decline using the Reliable Change Index. Of 437 participants, mild cognitive impairment was identified in 226 (51.7%) before the procedure. Computerized tests detected an incidence of cognitive decline of 10.0% at 24 hours and 7.5% at 7 days. At 3 months, written tests detected an incidence of cognitive decline of 13.1% and computerized tests detected an incidence of 8.5%. Cognitive decline at 3 months using written tests was associated with increasing age, whereas computerized tests showed cognitive decline was associated with baseline amnestic mild cognitive impairment, diabetes mellitus, and prior coronary stenting. More than half the patients aged >60 years presenting for LHC have mild cognitive impairment. LHC is followed by cognitive decline in 8% to 13% of individuals at 3 months after the procedure. Subtle cognitive decline both before and after LHC is common and may have important clinical implications. URL: www.anzctr.org.au. Unique identifier: ACTRN12607000051448. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  11. The effects of mild and severe traumatic brain injury on speed of information processing as measured by the computerized tests of information processing (CTIP).

    PubMed

    Tombaugh, Tom N; Rees, Laura; Stormer, Peter; Harrison, Allyson G; Smith, Andra

    2007-01-01

    In spite of the fact that reaction time (RT) measures are sensitive to the effects of traumatic brain injury (TBI), few RT procedures have been developed for use in standard clinical evaluations. The computerized test of information processing (CTIP) [Tombaugh, T. N., & Rees, L. (2000). Manual for the computerized tests of information processing (CTIP). Ottawa, Ont.: Carleton University] was designed to measure the degree to which TBI decreases the speed at which information is processed. The CTIP consists of three computerized programs that progressively increase the amount of information that is processed. Results of the current study demonstrated that RT increased as the difficulty of the CTIP tests increased (known as the complexity effect), and as severity of injury increased (from mild to severe TBI). The current study also demonstrated the importance of selecting a non-biased measure of variability. Overall, findings suggest that the CTIP is an easy to administer and sensitive measure of information processing speed.

  12. Learning effect of computerized cognitive tests in older adults

    PubMed Central

    de Oliveira, Rafaela Sanches; Trezza, Beatriz Maria; Busse, Alexandre Leopold; Jacob-Filho, Wilson

    2014-01-01

    ABSTRACT Objective: To evaluate the learning effect of computerized cognitive testing in the elderly. Methods: Cross-sectional study with 20 elderly, 10 women and 10 men, with average age of 77.5 (±4.28) years. The volunteers performed two series of computerized cognitive tests in sequence and their results were compared. The applied tests were: Trail Making A and B, Spatial Recognition, Go/No Go, Memory Span, Pattern Recognition Memory and Reverse Span. Results: Based on the comparison of the results, learning effects were observed only in the Trail Making A test (p=0.019). Other tests performed presented no significant performance improvements. There was no correlation between learning effect and age (p=0.337) and education (p=0.362), as well as differences between genders (p=0.465). Conclusion: The computerized cognitive tests repeated immediately afterwards, for elderly, revealed no change in their performance, with the exception of the Trail Making test, demonstrating high clinical applicability, even in short intervals. PMID:25003917

  13. Improving multitasking assessment in healthy older adults using a prop-based version of the Breakfast task.

    PubMed

    Kosowicz, Maria; MacPherson, Sarah E

    2017-01-01

    Computerized cognitive assessment is becoming increasingly more common in clinical neuropsychological assessment and cognitive neuropsychological research. A number of computerized tasks now exist to assess multitasking abilities that are essential for everyday tasks such as cooking, shopping, or driving, but little is known about whether these tasks are appropriate for assessing older adults' multitasking. The present study directly compared age effects on multitasking when assessed using a computerized and a prop-based version of Craik and Bialystok's ( 2006 ) Breakfast task. Twenty participants aged 18 to 24 years and 20 participants aged 60 to 79 years were assessed on both versions of the Breakfast task. While age-related decrements in multitasking performance were found using the computerized task, significant age differences were not found on the majority of measures when the prop-based version was administered. The results suggest that age-related deficits in multitasking will be less when more contextualized, noncomputer based tasks are used.

  14. External and internal macromorphology in 3D-reconstructed maxillary molars using computerized X-ray microtomography.

    PubMed

    Bjørndal, L; Carlsen, O; Thuesen, G; Darvann, T; Kreiborg, S

    1999-01-01

    The aim of this study was to perform a qualitative analysis of the relationship between the external and internal macromorphology of the root complex and to use fractal dimension analysis to determine the correlation between the shape of the outer surface of the root and the shape of the root canal. On the basis of X-ray computed transaxial microtomography, a qualitative and quantitative analysis of the external and internal macromorphology of the root complex in permanent maxillary molars was performed using well-defined macromorphological variables and fractal dimension analysis. Five maxillary molars were placed between a microfocus X-ray tube with a focal spot size of 0.07 mm, a Thomson-SCF image intensifier, and a CCD camera compromising a detector for the tomograph. Between 100 and 240 tomographic 2D slices were made of each tooth. Assembling slices for 3D volume was carried out with subsequent median noise filtering. Segmentation into enamel, dentine and pulp space was achieved through thresholding followed by morphological filtering. Surface representations were then constructed. A useful visualization of the tooth was created by making the dental hard tissues transparent and the pulp chamber and root-canal system opaque. On this basis it became possible to assess the relationship between the external and internal macromorphology of the crown and root complex. There was strong agreement between the number, position and cross-section of the root canals and the number, position and degree of manifestation of the root complex macrostructures. Data from a fractal dimension analysis also showed a high correlation between the shape of the root canals and the corresponding roots. It is suggested that these types of 3D volumes constitute a platform for preclinical training in fundamental endodontic procedures.

  15. [Digital signature: new prospects for the information of the cardiologic clinical card].

    PubMed

    Cervesato, E; Antonini-Canterin, F; Nicolosi, G L

    2001-02-01

    In the last few years, remarkable improvements have been made in computerized database systems used in cardiology. However, they will not easily lead to further relevant improvements unless the weaknesses and the gaps deriving from the obligation of forming and storing case sheets, according to law, are faced and resolved in an original way. This article covers the topic of the digital signature and how it could form the basis for a new powerful impulse to the process of informatization of cardiology records. The proposal of elaborating a totally computerized case sheet involves the need of rationalizing the flow of clinical information and of implementing a management system integrated with the hospital information system. The elimination of paper support will probably lead to an advantageous cycle that will involve the entire hospital, both clinically as well as administratively.

  16. A case study on the impacts of computerized provider order entry (CPOE) system on hospital clinical workflow.

    PubMed

    Mominah, Maher; Yunus, Faisel; Househ, Mowafa S

    2013-01-01

    Computerized provider order entry (CPOE) is a health informatics system that helps health care providers create and manage orders for medications and other health care services. Through the automation of the ordering process, CPOE has improved the overall efficiency of hospital processes and workflow. In Saudi Arabia, CPOE has been used for years, with only a few studies evaluating the impacts of CPOE on clinical workflow. In this paper, we discuss the experience of a local hospital with the use of CPOE and its impacts on clinical workflow. Results show that there are many issues related to the implementation and use of CPOE within Saudi Arabia that must be addressed, including design, training, medication errors, alert fatigue, and system dep Recommendations for improving CPOE use within Saudi Arabia are also discussed.

  17. Features of computerized clinical decision support systems supportive of nursing practice: a literature review.

    PubMed

    Lee, Seonah

    2013-10-01

    This study aimed to organize the system features of decision support technologies targeted at nursing practice into assessment, problem identification, care plans, implementation, and outcome evaluation. It also aimed to identify the range of the five stage-related sequential decision supports that computerized clinical decision support systems provided. MEDLINE, CINAHL, and EMBASE were searched. A total of 27 studies were reviewed. The system features collected represented the characteristics of each category from patient assessment to outcome evaluation. Several features were common across the reviewed systems. For the sequential decision support, all of the reviewed systems provided decision support in sequence for patient assessment and care plans. Fewer than half of the systems included problem identification. There were only three systems operating in an implementation stage and four systems in outcome evaluation. Consequently, the key steps for sequential decision support functions were initial patient assessment, problem identification, care plan, and outcome evaluation. Providing decision support in such a full scope will effectively help nurses' clinical decision making. By organizing the system features, a comprehensive picture of nursing practice-oriented computerized decision support systems was obtained; however, the development of a guideline for better systems should go beyond the scope of a literature review.

  18. Development of a computerized assessment of clinician adherence to a treatment guideline for patients with bipolar disorder.

    PubMed

    Dennehy, Ellen B; Suppes, Trisha; John Rush, A; Lynn Crismon, M; Witte, B; Webster, J

    2004-01-01

    The adoption of treatment guidelines for complex psychiatric illness is increasing. Treatment decisions in psychiatry depend on a number of variables, including severity of symptoms, past treatment history, patient preferences, medication tolerability, and clinical response. While patient outcomes may be improved by the use of treatment guidelines, there is no agreed upon standard by which to assess the degree to which clinician behavior corresponds to those recommendations. This report presents a method to assess clinician adherence to the complex multidimensional treatment guideline for bipolar disorder utilized in the Texas Medication Algorithm Project. The steps involved in the development of this system are presented, including the reliance on standardized documentation, defining core variables of interest, selecting criteria for operationalization of those variables, and computerization of the assessment of adherence. The computerized assessment represents an improvement over other assessment methods, which have relied on laborious and costly chart reviews to extract clinical information and to analyze provider behavior. However, it is limited by the specificity of decisions that guided the adherence scoring process. Preliminary findings using this system with 2035 clinical visits conducted for the bipolar disorder module of TMAP Phase 3 are presented. These data indicate that this system of guideline adherence monitoring is feasible.

  19. Pilot study on the feasibility of a computerized speech recognition charting system.

    PubMed

    Feldman, C A; Stevens, D

    1990-08-01

    The objective of this study was to determine the feasibility of developing and using a voice recognition computerized charting system to record dental clinical examination data. More specifically, the study was designed to analyze the time and error differential between the traditional examiner/recorder method (ASSISTANT) and computerized voice recognition method (VOICE). DMFS examinations were performed twice on 20 patients using the traditional ASSISTANT and the VOICE charting system. A statistically significant difference was found when comparing the mean ASSISTANT time of 2.69 min to the VOICE time of 3.72 min (P less than 0.001). No statistically significant difference was found when comparing the mean ASSISTANT recording errors of 0.1 to VOICE recording errors of 0.6 (P = 0.059). 90% of the patients indicated they felt comfortable with the dentist talking to a computer and only 5% of the sample indicated they opposed VOICE. Results from this pilot study indicate that a charting system utilizing voice recognition technology could be considered a viable alternative to traditional examiner/recorder methods of clinical charting.

  20. Is magnetic resonance imaging in addition to a computed tomographic scan necessary to identify clinically significant cervical spine injuries in obtunded blunt trauma patients?

    PubMed

    Fisher, Brian M; Cowles, Steven; Matulich, Jennifer R; Evanson, Bradley G; Vega, Diana; Dissanaike, Sharmila

    2013-12-01

    Guidelines are in place directing the clearance of the cervical spine in patients who are awake, alert, and oriented, but a gold standard has not been recognized for patients who are obtunded. Our study is designed to determine if magnetic resonance imaging (MRI) detects clinically significant injuries not seen on computed tomographic (CT) scans. The trauma registry was used to identify and retrospectively review medical records of blunt trauma patients from January 1, 2005, to March 30, 2012. Only obtunded patients with a CT scan and MRI of the cervical spine were included. The study cohort consisted of 277 patients. In 13 (5%) patients, MRI detected clinically significant cervical spine injuries that were missed by CT scans, and in 7 (3%) these injuries required intervention. The number needed to screen with MRI to prevent 1 missed injury was 21. The findings suggest that the routine use of MRI in clearing the cervical spine in the obtunded blunt trauma patient. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Fast 3-D Tomographic Microwave Imaging for Breast Cancer Detection

    PubMed Central

    Meaney, Paul M.; Kaufman, Peter A.; diFlorio-Alexander, Roberta M.; Paulsen, Keith D.

    2013-01-01

    Microwave breast imaging (using electromagnetic waves of frequencies around 1 GHz) has mostly remained at the research level for the past decade, gaining little clinical acceptance. The major hurdles limiting patient use are both at the hardware level (challenges in collecting accurate and noncorrupted data) and software level (often plagued by unrealistic reconstruction times in the tens of hours). In this paper we report improvements that address both issues. First, the hardware is able to measure signals down to levels compatible with sub-centimeter image resolution while keeping an exam time under 2 min. Second, the software overcomes the enormous time burden and produces similarly accurate images in less than 20 min. The combination of the new hardware and software allows us to produce and report here the first clinical 3-D microwave tomographic images of the breast. Two clinical examples are selected out of 400+ exams conducted at the Dartmouth Hitchcock Medical Center (Lebanon, NH). The first example demonstrates the potential usefulness of our system for breast cancer screening while the second example focuses on therapy monitoring. PMID:22562726

  2. Bilateral mandibular pyogranulomatous lymphadenitis and pulmonary nodules in a dog with Bartonella henselae bacteremia

    PubMed Central

    Tucker, Melissa D.; Sellon, Rance K.; Tucker, Russell L.; Wills, Tamara B.; Simonsen, Andrea; Maggi, Ricardo G.; Breitschwerdt, Edward B.

    2014-01-01

    This report describes a 2-year-old collie dog with pulmonary nodules, visualized by computed tomographic (CT) scan, with evidence of Bartonella henselae bacteremia and pyogranulomatous lymphadenitis. Clinical signs resolved with antimicrobial therapy. PMID:25320386

  3. Root Canal Treatment of Mandibular Second Premolar with Three Separate Roots and Canals Using Spiral Computed Tomographic

    PubMed Central

    Hariharavel, V. P.; Kumar, A. Ashok; Ganesh, C.; Aravindhan, R.

    2014-01-01

    Anatomic and internal morphology of a root canal system is more complex and differs for each individual tooth of which mandibular premolars have earned the reputation for having aberrant anatomy. The occurrence of three canals with three separate foramina in mandibular second premolars is very rare. A wider knowledge on both clinical and radiological anatomy especially spiral computed tomographic is absolutely essential for the success of endodontic treatment. These teeth may require skillful and special root canal special shaping and obturating techniques. This paper reports an unusual case of a mandibular second premolar with atypical canal pattern that was successfully treated endodontically. PMID:25101187

  4. Feasibility of Web-based Technology to Assess Adherence to Clinic Appointments in Youth with Sickle Cell Disease

    PubMed Central

    Modi, Avani C.; Crosby, Lori E.; Hines, Janelle; Drotar, Dennis; Mitchell, Monica J.

    2011-01-01

    Web-based tools to improve clinic attendance have been effectively used in pediatric conditions but have not been tested in pediatric sickle cell disease (SCD). The goal of this pilot study was to assess barriers to clinic attendance and the feasibility of a web-based assessment tool to promote problem-solving around clinic appointments. Study participants included 30 youth with SCD (M=11.7±3.5 years; 57% male; 60% HbSS; 20% HbSC; 17% HB+Thal) and their primary caregivers. Medical chart review indicated that 61% of participants attended at least two SCD clinic appointments in the past year. The primary barrier to clinic attendance was inability to take off from work/school (33%). Regarding feasibility and acceptability, the computerized program was well-received by patients and caregivers, with youth and caregivers reporting a high degree of usefulness and preference for computerized assessment. Results suggest that this innovative approach shows promise and should be tested on a larger sample of youth with SCD. PMID:22278205

  5. Computerized Clinical Simulations.

    ERIC Educational Resources Information Center

    Reinecker, Lynn

    1985-01-01

    Describes technique involved in designing a clinical simulation problem for the allied health field of respiratory therapy; discusses the structure, content, and scoring categories of the simulation; and provides a sample program which illustrates a programming technique in BASIC, including a program listing and a sample flowchart. (MBR)

  6. Computerized physician order entry from a chief information officer perspective.

    PubMed

    Cotter, Carole M

    2004-12-01

    Designing and implementing a computerized physician order entry system in the critical care units of a large urban hospital system is an enormous undertaking. With their significant potential to improve health care and significantly reduce errors, the time for computerized physician order entry or physician order management systems is past due. Careful integrated planning is the key to success, requiring multidisciplinary teams at all levels of clinical and administrative management to work together. Articulated from the viewpoint of the Chief Information Officer of Lifespan, a not-for-profit hospital system in Rhode Island, the vision and strategy preceding the information technology plan, understanding the system's current state, the gap analysis between current and future state, and finally, building and implementing the information technology plan are described.

  7. Effectiveness of computerized clinical decision support systems for asthma and chronic obstructive pulmonary disease in primary care: a systematic review.

    PubMed

    Fathima, Mariam; Peiris, David; Naik-Panvelkar, Pradnya; Saini, Bandana; Armour, Carol Lyn

    2014-12-02

    The use of computerized clinical decision support systems may improve the diagnosis and ongoing management of chronic diseases, which requires recurrent visits to multiple health professionals, disease and medication monitoring and modification of patient behavior. The aim of this review was to systematically review randomized controlled trials evaluating the effectiveness of computerized clinical decision systems (CCDSS) in the care of people with asthma and COPD. Randomized controlled trials published between 2003 and 2013 were searched using multiple electronic databases Medline, EMBASE, CINAHL, IPA, Informit, PsychINFO, Compendex, and Cochrane Clinical Controlled Trials Register databases. To be included, RCTs had to evaluate the role of the CCDSSs for asthma and/or COPD in primary care. Nineteen studies representing 16 RCTs met our inclusion criteria. The majority of the trials were conducted in patients with asthma. Study quality was generally high. Meta-analysis was not conducted because of methodological and clinical heterogeneity. The use of CCDSS improved asthma and COPD care in 14 of the 19 studies reviewed (74%). Nine of the nineteen studies showed statistically significant (p < 0.05) improvement in the primary outcomes measured. The majority of the studies evaluated health care process measures as their primary outcomes (10/19). Evidence supports the effectiveness of CCDSS in the care of people with asthma. However there is very little information of its use in COPD care. Although there is considerable improvement in the health care process measures and clinical outcomes through the use of CCDSSs, its effects on user workload and efficiency, safety, costs of care, provider and patient satisfaction remain understudied.

  8. Development of the Computerized Model of Performance-Based Measurement System to Measure Nurses' Clinical Competence.

    PubMed

    Liou, Shwu-Ru; Liu, Hsiu-Chen; Tsai, Shu-Ling; Cheng, Ching-Yu; Yu, Wei-Chieh; Chu, Tsui-Ping

    2016-04-01

    Critical thinking skills and clinical competence are for providing quality patient care. The purpose of this study is to develop the Computerized Model of Performance-Based Measurement system based on the Clinical Reasoning Model. The system can evaluate and identify learning needs for clinical competency and be used as a learning tool to increase clinical competency by using computers. The system includes 10 high-risk, high-volume clinical case scenarios coupled with questions testing clinical reasoning, interpersonal, and technical skills. Questions were sequenced to reflect patients' changing condition and arranged by following the process of collecting and managing information, diagnosing and differentiating urgency of problems, and solving problems. The content validity and known-groups validity was established. The Kuder-Richardson Formula 20 was 0.90 and test-retest reliability was supported (r = 0.78). Nursing educators can use the system to understand students' needs for achieving clinical competence, and therefore, educational plans can be made to better prepare students and facilitate their smooth transition to a future clinical environment. Clinical nurses can use the system to evaluate their performance-based abilities and weakness in clinical reasoning. Appropriate training programs can be designed and implemented to practically promote nurses' clinical competence and quality of patient care.

  9. Modifications and integration of the electronic tracking board in a pediatric emergency department.

    PubMed

    Dexheimer, Judith W; Kennebeck, Stephanie

    2013-07-01

    Electronic health records (EHRs) are used for data storage; provider, laboratory, and patient communication; clinical decision support; procedure and medication orders; and decision support alerts. Clinical decision support is part of any EHR and is designed to help providers make better decisions. The emergency department (ED) poses a unique environment to the use of EHRs and clinical decision support. Used effectively, computerized tracking boards can help improve flow, communication, and the dissemination of pertinent visit information between providers and other departments in a busy ED. We discuss the unique modifications and decisions made in the implementation of an EHR and computerized tracking board in a pediatric ED. We discuss the changing views based on provider roles, customization to the user interface including the layout and colors, decision support, tracking board best practices collected from other institutions and colleagues, and a case study of using reminders on the electronic tracking board to drive pain reassessments.

  10. Computerized scintigraphic technique for the evaluation of adult respiratory distress syndrome: initial clinical trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tatum, J.L.; Burke, T.S.; Sugerman, H.T.

    1982-04-01

    Eleven patients with suspected adult respiratory distress syndrome (ARDS) and five control patients were studied using a computerized gamma imaging and analysis technique and /sup 99m/Tc-labeled human serum albumin. The heart and right lung were imaged, lung:heart ratio was plotted vs. time, and a linear regression was fitted to the data points displayed. The slope of this fit was termed the ''slope index.'' An index value of 2 standard deviations greater than the control mean was considered positive. Radiographs from the six positive studies revealed typical diffuse air-space disease. Radiographs from two of the five negative studies demonstrated air-space consolidation.more » Both of these patients had elevated pulmonary capillary wedge pressure, cardiomegaly, and clinical course consistent with cardiogenic pulmonary edema. These preliminary data demonstrated a good correlation between positive slope index and clinical ARDS.« less

  11. Computerized scintigraphic technique for the evaluation of adult respiratory distress syndrome: initial clinical trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tatum, J.L.; Burke, T.S.; Sugerman, H.J.

    1982-04-01

    Eleven patients with suspected adult respiratory distress syndrome (ARDS) and five control patients were studied using a computerized gamma imaging and analysis technique and 99mTc-labeled human serum albumin. The heart and right lung were imaged, lung:heart ratio was plotted vs. time, and a linear regression was fitted to the data points displayed. The slope of this fit was termed the ''slope index.'' An index value of 2 standard deviations greater than the control mean was considered positive. Radiographs from the six positive studies revealed typical diffuse air-space disease. Radiographs from two of the five negative studies demonstrated air-space consolidation. Bothmore » of these patients had elevated pulmonary capillary wedge pressure, cardiomegaly, and clinical course consistent with cardiogenic pulmonary edema. These preliminary data demonstrated a good correlation between positive slope index and clinical ARDS.« less

  12. [Use of computerized stabylometric footboard in evaluation of work suitability at height work in building firms].

    PubMed

    D'Orso, M I; Garaguso, M; Ferrari, G; Riva, M A; Gallamini, M; Cesana, G

    2012-01-01

    A relevant part of deadly work accidents and of severe work accidents reported in national specific statistics coming from INAIL is until today caused by workers' falls during their at height work activities. Medical evaluation of eventual workers' hyper susceptibility to fall caused by balance alterations, if included in medical surveillance, is frequently carried out by medical doctors using different subjective tests included in different clinical protocols. Use of a computerized stabylometric footboard on the contrary allows to obtain objective and reproducible data concerning vestibular function which, associated with traditional clinical medical evaluation, seem to better detect eventual presence of balance disturbances, especially those non clinically perceivable by workers and therefore more dangerous. We report results evidenced in a research carried out in a group of 185 workers engaged in building firms and having work tasks including phases of at height work.

  13. Virtual Physical Therapy Clinician: Development, Validation and Testing

    ERIC Educational Resources Information Center

    Huhn, Karen

    2011-01-01

    Introduction: Clinical reasoning skills develop through repeated practice in realistic patient scenarios. Time constraints, declining availability of clinical education sites and patient safety are some of the factors that limit physical therapy educators' ability to expose students to realistic patient scenarios. Computerized simulations may be…

  14. Towards Omni-Tomography—Grand Fusion of Multiple Modalities for Simultaneous Interior Tomography

    PubMed Central

    Wang, Ge; Zhang, Jie; Gao, Hao; Weir, Victor; Yu, Hengyong; Cong, Wenxiang; Xu, Xiaochen; Shen, Haiou; Bennett, James; Furth, Mark; Wang, Yue; Vannier, Michael

    2012-01-01

    We recently elevated interior tomography from its origin in computed tomography (CT) to a general tomographic principle, and proved its validity for other tomographic modalities including SPECT, MRI, and others. Here we propose “omni-tomography”, a novel concept for the grand fusion of multiple tomographic modalities for simultaneous data acquisition in a region of interest (ROI). Omni-tomography can be instrumental when physiological processes under investigation are multi-dimensional, multi-scale, multi-temporal and multi-parametric. Both preclinical and clinical studies now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities. Over the past decade, two approaches have been used for multimodality fusion: Software based image registration and hybrid scanners such as PET-CT, PET-MRI, and SPECT-CT among others. While there are intrinsic limitations with both approaches, the main obstacle to the seamless fusion of multiple imaging modalities has been the bulkiness of each individual imager and the conflict of their physical (especially spatial) requirements. To address this challenge, omni-tomography is now unveiled as an emerging direction for biomedical imaging and systems biomedicine. PMID:22768108

  15. Virtual endoscopic imaging of the spine.

    PubMed

    Kotani, Toshiaki; Nagaya, Shigeyuki; Sonoda, Masaru; Akazawa, Tsutomu; Lumawig, Jose Miguel T; Nemoto, Tetsuharu; Koshi, Takana; Kamiya, Koshiro; Hirosawa, Naoya; Minami, Shohei

    2012-05-20

    Prospective trial of virtual endoscopy in spinal surgery. To investigate the utility of virtual endoscopy of the spine in conjunction with spinal surgery. Several studies have described clinical applications of virtual endoscopy to visualize the inside of the bronchi, paranasal sinus, stomach, small intestine, pancreatic duct, and bile duct, but, to date, no study has described the use of virtual endoscopy in the spine. Virtual endoscopy is a realistic 3-dimensional intraluminal simulation of tubular structures that is generated by postprocessing of computed tomographic data sets. Five patients with spinal disease were selected: 2 patients with degenerative disease, 2 patients with spinal deformity, and 1 patient with spinal injury. Virtual endoscopy software allows an observer to explore the spinal canal with a mouse, using multislice computed tomographic data. Our study found that virtual endoscopy of the spine has advantages compared with standard imaging methods because surgeons can noninvasively explore the spinal canal in all directions. Virtual endoscopy of the spine may be useful to surgeons for diagnosis, preoperative planning, and postoperative assessment by obviating the need to mentally construct a 3-dimensional picture of the spinal canal from 2-dimensional computed tomographic scans.

  16. Clinical Information Systems - From Yesterday to Tomorrow.

    PubMed

    Gardner, R M

    2016-06-30

    To review the history of clinical information systems over the past twenty-five years and project anticipated changes to those systems over the next twenty-five years. Over 250 Medline references about clinical information systems, quality of patient care, and patient safety were reviewed. Books, Web resources, and the author's personal experience with developing the HELP system were also used. There have been dramatic improvements in the use and acceptance of clinical computing systems and Electronic Health Records (EHRs), especially in the United States. Although there are still challenges with the implementation of such systems, the rate of progress has been remarkable. Over the next twenty-five years, there will remain many important opportunities and challenges. These opportunities include understanding complex clinical computing issues that must be studied, understood and optimized. Dramatic improvements in quality of care and patient safety must be anticipated as a result of the use of clinical information systems. These improvements will result from a closer involvement of clinical informaticians in the optimization of patient care processes. Clinical information systems and computerized clinical decision support have made contributions to medicine in the past. Therefore, by using better medical knowledge, optimized clinical information systems, and computerized clinical decision, we will enable dramatic improvements in both the quality and safety of patient care in the next twenty-five years.

  17. In person versus Computer Screening for Intimate Partner Violence Among Pregnant Patients

    PubMed Central

    Dado, Diane; Schussler, Sara; Hawker, Lynn; Holland, Cynthia L.; Burke, Jessica G.; Cluss, Patricia A.

    2012-01-01

    Objective To compare in person versus computerized screening for intimate partner violence (IPV) in a hospital-based prenatal clinic and explore women’s assessment of the screening methods. Methods We compared patient IPV disclosures on a computerized questionnaire to audio-taped first obstetric visits with an obstetric care provider and performed semi-structured interviews with patient participants who reported experiencing IPV. Results Two-hundred and fifty patient participants and 52 provider participants were in the study. Ninety-one (36%) patients disclosed IPV either via computer or in person. Of those who disclosed IPV, 60 (66%) disclosed via both methods, but 31 (34%) disclosed IPV via only one of the two methods. Twenty-three women returned for interviews. They recommended using both types together. While computerized screening was felt to be non-judgmental and more anonymous, in person screening allowed for tailored questioning and more emotional connection with the provider. Conclusion Computerized screening allowed disclosure without fear of immediate judgment. In person screening allows more flexibility in wording of questions regarding IPV and opportunity for interpersonal rapport. Practice Implications Both computerized or self-completed screening and in person screening is recommended. Providers should address IPV using non-judgmental, descriptive language, include assessments for psychological IPV, and repeat screening in person, even if no patient disclosure occurs via computer. PMID:22770815

  18. In person versus computer screening for intimate partner violence among pregnant patients.

    PubMed

    Chang, Judy C; Dado, Diane; Schussler, Sara; Hawker, Lynn; Holland, Cynthia L; Burke, Jessica G; Cluss, Patricia A

    2012-09-01

    To compare in person versus computerized screening for intimate partner violence (IPV) in a hospital-based prenatal clinic and explore women's assessment of the screening methods. We compared patient IPV disclosures on a computerized questionnaire to audio-taped first obstetric visits with an obstetric care provider and performed semi-structured interviews with patient participants who reported experiencing IPV. Two-hundred and fifty patient participants and 52 provider participants were in the study. Ninety-one (36%) patients disclosed IPV either via computer or in person. Of those who disclosed IPV, 60 (66%) disclosed via both methods, but 31 (34%) disclosed IPV via only one of the two methods. Twenty-three women returned for interviews. They recommended using both types together. While computerized screening was felt to be non-judgmental and more anonymous, in person screening allowed for tailored questioning and more emotional connection with the provider. Computerized screening allowed disclosure without fear of immediate judgment. In person screening allows more flexibility in wording of questions regarding IPV and opportunity for interpersonal rapport. Both computerized or self-completed screening and in person screening is recommended. Providers should address IPV using non-judgmental, descriptive language, include assessments for psychological IPV, and repeat screening in person, even if no patient disclosure occurs via computer. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Effectiveness of a computerized alert system based on re-testing intervals for limiting the inappropriateness of laboratory test requests.

    PubMed

    Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo

    2015-11-01

    There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; p<0.001). The total financial saving of test withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Volume changes of autogenous bone after sinus lifting and grafting procedures: a 6-year computerized tomographic follow-up.

    PubMed

    Sbordone, Carolina; Toti, Paolo; Guidetti, Franco; Califano, Luigi; Bufo, Pantaleo; Sbordone, Ludovico

    2013-04-01

    To evaluate long-term bone remodelling of autografts over time (annually, for 6 years), comparing the block and particulate bone procedures for sinus floor elevation, as well as to evaluate the survival of positioned dental implants. Twenty-three sinus lift procedures with autogenous bone were performed: seven sinus lift procedures using particulate graft and 10 with block autogenous bone were performed in 17 patients. Employing a software program, pre- and post-surgical computerized tomography (CT) scans were used to compare the volume (V) and density (D) of inlay grafts over time (up to 6 years), and to determine the percentage of remaining bone (%R). All variable (V, D and %R) measurements were then compared statistically. At the 6-year survey for block form, a resorption of 21.5% was seen, whereas for particulate grafts there was a resorption of 39.2%. Both groups exhibited bone remodelling between the first and second follow-up which was significant regarding volume for the block form and regarding density for the particulate group. During the initial period of healing, the cortico-cancellous block bone grafted into the maxillary sinus underwent a negative remodelling of the volume, which is most probably due to graft cortex resorption, coupled with, primarily, an increase in density in the spongious area; for the particulate grafts, significant augmentations in density were obtained. The lack of significant differences among volumes was due to the wide degree of dispersion of the data. The rough data presented in this paper seem to support the use of a bone-block grafting procedure in maxillary sinus augmentation. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Surgically Assisted Rapid Palatomaxillary Expansion With or Without Pterygomaxillary Disjunction: A Systematic Review and Meta-Analysis.

    PubMed

    Hamedi Sangsari, Adrien; Sadr-Eshkevari, Pooyan; Al-Dam, Ahmed; Friedrich, Reinhard E; Freymiller, Earl; Rashad, Ashkan

    2016-02-01

    The purpose of this review was to evaluate the outcome measurements of anterior expansion, posterior expansion, and complications after surgically assisted rapid palatal expansion (SARPE) with or without pterygomaxillary disjunction (PMD). A computerized database search was performed using PubMed, CINAHL, Cochrane, Scopus, and Web of Science. Then, a computerized search was conducted in Google Scholar and ProQuest to overcome publication bias. From the original 125 combined results, 3 met the inclusion criteria. The Quality Assessment Tool for Quantitative Studies of the Effective Public Health Practice Project assessed 2 articles as weak and 1 as moderate. The systematic review included a total of 48 patients (11 male and 37 female). For 25 patients, SARPE was performed with PMD and for 23 patients SARPE was performed without PMD. A tooth-borne fixed hyrax-type palatal expansion screw appliance was used for all cases, activated 1 to 2 mm intraoperatively, and, after a latency period of 3 to 7 days, activated 0.5 to 0.6 mm per day for 38 patients and 0.25 mm for the other 10 until adequate expansion. Postexpansion retention was performed using ligature wired hyrax in 18 patients for 4 months. Comparisons were based on cone-beam computed tomographic projections, study models only, or a combination of study models, anteroposterior cephalometric radiographs, and occlusal radiographs. The time to measure the changes ranged from before fixed orthodontic retention to 6 months after the completion of active expansion. A meta-analysis was possible only for anterior (intercanine) and posterior (inter-molar) dental expansions. The literature is inconclusive regarding the effect of PMD on the outcomes of SARPE. Further controlled trials are needed. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Computerized cognitive testing in patients with type I Gaucher disease: effects of enzyme replacement and substrate reduction.

    PubMed

    Elstein, Deborah; Guedalia, Judith; Doniger, Glen M; Simon, Ely S; Antebi, Vered; Arnon, Yael; Zimran, Ari

    2005-02-01

    Because of concern for drug-induced cognitive dysfunction during clinical trials using substrate reduction therapy (miglustat) in type 1 Gaucher disease and because it has been suggested that some patients with type 1 Gaucher disease may develop neurocognitive impairment as part of the natural history, two different batteries of neuropsychological tests were devised to examine these issues. Using these tests, cognitive function was assessed in patients treated with miglustat, in patients receiving enzyme replacement (standard care for symptomatic patients), and in untreated (milder) patients. For this study, 55/60 patients exposed to miglustat in Israel participated in psychologist-administered testing; 36/55 participated in computerized testing. Of these, 31 enzyme-treated patients and 22 untreated patients participated in the psychologist-administered testing, and 15 enzyme-treated patients and 18 untreated patients participated in computerized testing. The psychologist-administered battery consisted of 18 standard neuropsychological subtests specific to executive and visuospatial functioning. The computerized battery (Mindstreams, NeuroTrax Corp., New York, NY) consisted of 10 subtests tapping multiple cognitive domains. Between-group analyses for each modality compared cognitive performance. In the psychologist-administered testing, patients exposed to miglustat performed significantly less well than the other groups in 5/18 subtests. On the computerized tests, all patients performed comparably to normal controls. Scores in patients exposed to miglustat were higher than in untreated patients, particularly in visuospatial function, whereas enzyme-treated patients performed less well. However, with the exception of visuospatial function, these results were not statistically significant. It is unclear why different testing methods yielded discordant results. Any dysfunction suggested by the current study is apparently subtle and of doubtful clinical relevance given that cognitive status did not interfere with patients' daily intellectual function. The computerized battery has methodological advantages (e.g., language options, objectivity, brevity, and ease of use) that make it well-suited for longitudinal studies, for long-term surveillance of substrate reduction therapy as well as for comparisons with other lysosomal storage disorders and other chronic diseases. These preliminary findings should allay fears of cognitive dysfunction due to short-term miglustat therapy.

  3. Computerized tomography versus magnetic resonance imaging: a comparative study in hypothalamic-pituitary and parasellar pathology.

    PubMed

    Webb, S M; Ruscalleda, J; Schwarzstein, D; Calaf-Alsina, J; Rovira, A; Matos, G; Puig-Domingo, M; de Leiva, A

    1992-05-01

    We wished to analyse the relative value of computerized tomography and magnetic resonance in patients referred for evaluation of pituitary and parasellar lesions. We performed a separate evaluation by two independent neuroradiologists of computerized tomography and magnetic resonance images ordered numerically and anonymously, with no clinical data available. We studied 40 patients submitted for hypothalamic-pituitary study; 31 were carried out preoperatively, of which histological confirmation later became available in 14. The remaining nine patients were evaluated postoperatively. Over 40 parameters relating to the bony margins, cavernous sinuses, carotid arteries, optic chiasm, suprasellar cisterns, pituitary, pituitary stalk and extension of the lesion were evaluated. These reports were compared with the initial ones offered when the scans were ordered, and with the final diagnosis. Concordance between initial computerized tomography and magnetic resonance was observed in 27 cases (67.5%); among the discordant cases computerized tomography showed the lesion in two, magnetic resonance in 10, while in the remaining case reported to harbour a microadenoma on computerized tomography the differential diagnosis between a true TSH-secreting microadenoma and pituitary resistance to thyroid hormones is still unclear. Both neuroradiologists coincided in their reports in 32 patients (80%); when the initial report was compared with those of the neuroradiologists, concordance was observed with at least one of them in 34 instances (85%). Discordant results were observed principally in microadenomas secreting ACTH or PRL and in delayed puberty. In the eight patients with Cushing's disease (histologically confirmed in six) magnetic resonance was positive in five and computerized tomography in two; the abnormal image correctly identified the side of the lesion at surgery. In patients referred for evaluation of Cushing's syndrome or hyperprolactinaemia (due to microadenomas) or after surgery, magnetic resonance is clearly preferable to computerized tomography. In macroadenomas both scans are equally diagnostic but magnetic resonance offers more information on pituitary morphology and neighbouring structures. Nevertheless, there are cases in which the results of computerized tomography and magnetic resonance will complement each other, since different parameters are analysed with each examination and discordant results are encountered.

  4. Towards computerizing intensive care sedation guidelines: design of a rule-based architecture for automated execution of clinical guidelines

    PubMed Central

    2010-01-01

    Background Computerized ICUs rely on software services to convey the medical condition of their patients as well as assisting the staff in taking treatment decisions. Such services are useful for following clinical guidelines quickly and accurately. However, the development of services is often time-consuming and error-prone. Consequently, many care-related activities are still conducted based on manually constructed guidelines. These are often ambiguous, which leads to unnecessary variations in treatments and costs. The goal of this paper is to present a semi-automatic verification and translation framework capable of turning manually constructed diagrams into ready-to-use programs. This framework combines the strengths of the manual and service-oriented approaches while decreasing their disadvantages. The aim is to close the gap in communication between the IT and the medical domain. This leads to a less time-consuming and error-prone development phase and a shorter clinical evaluation phase. Methods A framework is proposed that semi-automatically translates a clinical guideline, expressed as an XML-based flow chart, into a Drools Rule Flow by employing semantic technologies such as ontologies and SWRL. An overview of the architecture is given and all the technology choices are thoroughly motivated. Finally, it is shown how this framework can be integrated into a service-oriented architecture (SOA). Results The applicability of the Drools Rule language to express clinical guidelines is evaluated by translating an example guideline, namely the sedation protocol used for the anaesthetization of patients, to a Drools Rule Flow and executing and deploying this Rule-based application as a part of a SOA. The results show that the performance of Drools is comparable to other technologies such as Web Services and increases with the number of decision nodes present in the Rule Flow. Most delays are introduced by loading the Rule Flows. Conclusions The framework is an effective solution for computerizing clinical guidelines as it allows for quick development, evaluation and human-readable visualization of the Rules and has a good performance. By monitoring the parameters of the patient to automatically detect exceptional situations and problems and by notifying the medical staff of tasks that need to be performed, the computerized sedation guideline improves the execution of the guideline. PMID:20082700

  5. Towards computerizing intensive care sedation guidelines: design of a rule-based architecture for automated execution of clinical guidelines.

    PubMed

    Ongenae, Femke; De Backere, Femke; Steurbaut, Kristof; Colpaert, Kirsten; Kerckhove, Wannes; Decruyenaere, Johan; De Turck, Filip

    2010-01-18

    Computerized ICUs rely on software services to convey the medical condition of their patients as well as assisting the staff in taking treatment decisions. Such services are useful for following clinical guidelines quickly and accurately. However, the development of services is often time-consuming and error-prone. Consequently, many care-related activities are still conducted based on manually constructed guidelines. These are often ambiguous, which leads to unnecessary variations in treatments and costs.The goal of this paper is to present a semi-automatic verification and translation framework capable of turning manually constructed diagrams into ready-to-use programs. This framework combines the strengths of the manual and service-oriented approaches while decreasing their disadvantages. The aim is to close the gap in communication between the IT and the medical domain. This leads to a less time-consuming and error-prone development phase and a shorter clinical evaluation phase. A framework is proposed that semi-automatically translates a clinical guideline, expressed as an XML-based flow chart, into a Drools Rule Flow by employing semantic technologies such as ontologies and SWRL. An overview of the architecture is given and all the technology choices are thoroughly motivated. Finally, it is shown how this framework can be integrated into a service-oriented architecture (SOA). The applicability of the Drools Rule language to express clinical guidelines is evaluated by translating an example guideline, namely the sedation protocol used for the anaesthetization of patients, to a Drools Rule Flow and executing and deploying this Rule-based application as a part of a SOA. The results show that the performance of Drools is comparable to other technologies such as Web Services and increases with the number of decision nodes present in the Rule Flow. Most delays are introduced by loading the Rule Flows. The framework is an effective solution for computerizing clinical guidelines as it allows for quick development, evaluation and human-readable visualization of the Rules and has a good performance. By monitoring the parameters of the patient to automatically detect exceptional situations and problems and by notifying the medical staff of tasks that need to be performed, the computerized sedation guideline improves the execution of the guideline.

  6. In vivo multiphoton tomography and fluorescence lifetime imaging of human brain tumor tissue.

    PubMed

    Kantelhardt, Sven R; Kalasauskas, Darius; König, Karsten; Kim, Ella; Weinigel, Martin; Uchugonova, Aisada; Giese, Alf

    2016-05-01

    High resolution multiphoton tomography and fluorescence lifetime imaging differentiates glioma from adjacent brain in native tissue samples ex vivo. Presently, multiphoton tomography is applied in clinical dermatology and experimentally. We here present the first application of multiphoton and fluorescence lifetime imaging for in vivo imaging on humans during a neurosurgical procedure. We used a MPTflex™ Multiphoton Laser Tomograph (JenLab, Germany). We examined cultured glioma cells in an orthotopic mouse tumor model and native human tissue samples. Finally the multiphoton tomograph was applied to provide optical biopsies during resection of a clinical case of glioblastoma. All tissues imaged by multiphoton tomography were sampled and processed for conventional histopathology. The multiphoton tomograph allowed fluorescence intensity- and fluorescence lifetime imaging with submicron spatial resolution and 200 picosecond temporal resolution. Morphological fluorescence intensity imaging and fluorescence lifetime imaging of tumor-bearing mouse brains and native human tissue samples clearly differentiated tumor and adjacent brain tissue. Intraoperative imaging was found to be technically feasible. Intraoperative image quality was comparable to ex vivo examinations. To our knowledge we here present the first intraoperative application of high resolution multiphoton tomography and fluorescence lifetime imaging of human brain tumors in situ. It allowed in vivo identification and determination of cell density of tumor tissue on a cellular and subcellular level within seconds. The technology shows the potential of rapid intraoperative identification of native glioma tissue without need for tissue processing or staining.

  7. Computerized Assessment of Competence-Related Abilities in Living Liver Donors: The Adult-to-Adult Living Donor Liver Transplantation Cohort Study (A2ALL)

    PubMed Central

    Freeman, Jason; Emond, Jean; Gillespie, Brenda W.; Appelbaum, Paul S.; Weinrieb, Robert; Hill-Callahan, Peg; Gordon, Elisa J.; Terrault, Norah; Trotter, James; Ashworth, April; Dew, Mary Amanda; Pruett, Timothy

    2014-01-01

    Background Despite its importance, determination of competence to consent to organ donation varies widely based on local standards. We piloted a new tool to aid transplant centers in donor assessment. Methods We assessed competence-related abilities among potential living liver donors (LDs) in the 9-center A2ALL study. Prospective LDs viewed an educational video, and were queried to assess Understanding, Appreciation, Reasoning, and ability to express a Final Choice using the MacArthur Competence Assessment Tool for Clinical Research, adapted for computerized administration in LDs (“MacLiver”). Videotaped responses were scored by a clinical neuropsychologist (JF). Results Ninety-three LDs were assessed. Mean (standard deviation; domain maximum) scores were: Understanding: 18.1 (2.6; max=22), Appreciation: 5.1 (1.0; max=6), Reasoning: 3.1 (0.8; max=4), and Final Choice: 3.8 (0.5; max=4). Scores did not differ by demographics, relationship to the recipient, eligibility to donate, or eventual donation (p>0.4). Higher education was associated with greater Understanding (p=0.004) and Reasoning (p=0.03). Conclusion Standardized, computerized education with independent ratings of responses may (1) alert the clinical staff to potential donors who may not be competent to donate, and (2) highlight areas needing further assessment and education, leading to better informed decision-making. PMID:23859354

  8. Coupling computer-interpretable guidelines with a drug-database through a web-based system – The PRESGUID project

    PubMed Central

    Dufour, Jean-Charles; Fieschi, Dominique; Fieschi, Marius

    2004-01-01

    Background Clinical Practice Guidelines (CPGs) available today are not extensively used due to lack of proper integration into clinical settings, knowledge-related information resources, and lack of decision support at the point of care in a particular clinical context. Objective The PRESGUID project (PREScription and GUIDelines) aims to improve the assistance provided by guidelines. The project proposes an online service enabling physicians to consult computerized CPGs linked to drug databases for easier integration into the healthcare process. Methods Computable CPGs are structured as decision trees and coded in XML format. Recommendations related to drug classes are tagged with ATC codes. We use a mapping module to enhance computerized guidelines coupling with a drug database, which contains detailed information about each usable specific medication. In this way, therapeutic recommendations are backed up with current and up-to-date information from the database. Results Two authoritative CPGs, originally diffused as static textual documents, have been implemented to validate the computerization process and to illustrate the usefulness of the resulting automated CPGs and their coupling with a drug database. We discuss the advantages of this approach for practitioners and the implications for both guideline developers and drug database providers. Other CPGs will be implemented and evaluated in real conditions by clinicians working in different health institutions. PMID:15053828

  9. Assessment of the Biomechanical Performance of 5 Plating Techniques in Fixation of Mandibular Subcondylar Fracture Using Finite Element Analysis.

    PubMed

    Darwich, Mhd Ayham; Albogha, Mhd Hassan; Abdelmajeed, Adnan; Darwich, Khaldoun

    2016-04-01

    The aim of this study was to compare the performances of 5 plating techniques for fixation of unilateral mandibular subcondylar fracture. Five titanium plating techniques for fixation of condylar fracture were analyzed using the finite element method. The modeled techniques were 1) 1 straight plate, 2) 2 parallel straight plates, 3) 2 angulated straight plates, 4) 1 trapezoidal plate, and 5) 1 square plate. Three-dimensional models were generated using patient-specific geometry for the mandible obtained from a computerized tomographic image of a healthy living man. Plates were designed and combined with the mandible and analyzed under a 500-N load. The single straight plate presented the most inferior performance; it presented maximum displacement and strain on cortical bone. The trapezoidal plate induced the least amount of strain on cortical bone and was best at resisting displacement. The trapezoidal plate is recommended for fixation of subcondylar fracture. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Current Trends in the Management of Abdominal Aortic Aneurysms

    PubMed Central

    Harris, K.A.; Ameli, F. Michael; Louis, E.L. St.

    1987-01-01

    The treatment of abdominal aortic aneurysm has undergone dramatic changes over the last three decades. More sophisticated diagnostic techniques have allowed early elective repair to be carried out. Improvement has resulted in both morbidity and mortality rates. Investigations such as ultrasound, computerized tomographic scanning and arteriography allow easy confirmation of the diagnosis of aortic aneurysms and permit a better assessment of the extent prior to surgical intervention. Improvement in the pre-operative management, particularly in relation to cardiac, renal, and pulmonary disease, has led to greatly improved results. The most important change in surgical technique has been repair of the aneurysm rather than resection. Combined with better post-operative intensive care units, this development has contributed to the improved morbidity and mortality rates. Although the complication rate of elective repair is low, the major cause of death remains myocardial infarction. As a result of all these improvements, indication for repair of abdominal aortic aneurysms has been extended to patients over the age of 80. Following surgical repair, most patients can be expected to return to normal lifestyles and lifespans. ImagesFigure 2Figure 3Figure 4 PMID:21263973

  11. Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coupe, Nicholas J., E-mail: optimus2050@hotmail.com; Ling, Lynn; Cowling, Mark G.

    2009-07-15

    We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was alsomore » not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.« less

  12. False-Positive Cases of Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomographic Scans in Metastasis of Esophageal Cancer

    PubMed Central

    Yamatsuji, Tomoki; Ishida, Naomasa; Takaoka, Munenori; Hayashi, Jiro; Yoshida, Kazuhiro; Shigemitsu, Kaori; Urakami, Atsushi; Haisa, Minoru; Naomoto, Yoshio

    2017-01-01

    Of 129 esophagectomies at our institute from June 2010 to March 2015, we experienced three preoperative positron emission tomography-computed tomographic (PET/CT) false positives. Bone metastasis was originally suspected in 2 cases, but they were later found to be bone metastasis negative after a preoperative bone biopsy and clinical course observation. The other cases suspected of mediastinal lymph node metastasis were diagnosed as inflammatory lymphadenopathy by a pathological examination of the removed lymph nodes. Conducting a PET/CT is useful when diagnosing esophageal cancer metastasis, but we need to be aware of the possibility of false positives. Therapeutic decisions should be made based on appropriate and accurate diagnoses, with pathological diagnosis actively introduced if necessary. PMID:28469502

  13. Outcome assessment via handheld computer in community mental health: consumer satisfaction and reliability.

    PubMed

    Goldstein, Lizabeth A; Connolly Gibbons, Mary Beth; Thompson, Sarah M; Scott, Kelli; Heintz, Laura; Green, Patricia; Thompson, Donald; Crits-Christoph, Paul

    2011-07-01

    Computerized administration of mental health-related questionnaires has become relatively common, but little research has explored this mode of assessment in "real-world" settings. In the current study, 200 consumers at a community mental health center completed the BASIS-24 via handheld computer as well as paper and pen. Scores on the computerized BASIS-24 were compared with scores on the paper BASIS-24. Consumers also completed a questionnaire which assessed their level of satisfaction with the computerized BASIS-24. Results indicated that the BASIS-24 administered via handheld computer was highly correlated with pen and paper administration of the measure and was generally acceptable to consumers. Administration of the BASIS-24 via handheld computer may allow for efficient and sustainable outcomes assessment, adaptable research infrastructure, and maximization of clinical impact in community mental health agencies.

  14. Implementing computerized physician order entry: the importance of special people.

    PubMed

    Ash, Joan S; Stavri, P Zoë; Dykstra, Richard; Fournier, Lara

    2003-03-01

    To articulate important lessons learned during a study to identify success factors for implementing computerized physician order entry (CPOE) in inpatient and outpatient settings. Qualitative study by a multidisciplinary team using data from observation, focus groups, and both formal and informal interviews. Data were analyzed using a grounded approach to develop a taxonomy of patterns and themes from the transcripts and field notes. The theme we call Special People is explored here in detail. A taxonomy of types of Special People includes administrative leaders, clinical leaders (champions, opinion leaders, and curmudgeons), and bridgers or support staff who interface directly with users. The recognition and nurturing of Special People should be among the highest priorities of those implementing computerized physician order entry. Their education and training must be a goal of teaching programs in health administration and medical informatics.

  15. The VA Computerized Patient Record — A First Look

    PubMed Central

    Anderson, Curtis L.; Meldrum, Kevin C.

    1994-01-01

    In support of its in-house DHCP Physician Order Entry/Results Reporting application, the VA is developing the first edition of a Computerized Patient Record. The system will feature a physician-oriented interface with real time, expert system-based order checking, a controlled vocabulary, a longitudinal repository of patient data, HL7 messaging support, a clinical reminder and warning system, and full integration with existing VA applications including lab, pharmacy, A/D/T, radiology, dietetics, surgery, vitals, allergy tracking, discharge summary, problem list, progress notes, consults, and online physician order entry. PMID:7949886

  16. Automated Computerized Analysis of Speechin Psychiatric Disorders

    PubMed Central

    Cohen, Alex S.; Elvevåg, Brita

    2014-01-01

    Purpose of Review Disturbances in communication are a hallmark of severe mental illnesses. Recent technological advances have paved the way for objectifying communication using automated computerized linguistic and acoustic analysis. We review recent studies applying various computer-based assessments to the natural language produced by adult patients with severe mental illness. Recent Findings Automated computerized methods afford tools with which it is possible to objectively evaluate patients in a reliable, valid and efficient manner that complements human ratings. Crucially, these measures correlate with important clinical measures. The clinical relevance of these novel metrics has been demonstrated by showing their relationship to functional outcome measures, their in vivo link to classic ‘language’ regions in the brain, and, in the case of linguistic analysis, their relationship to candidate genes for severe mental illness. Summary Computer based assessments of natural language afford a framework with which to measure communication disturbances in adults with SMI. Emerging evidence suggests that they can be reliable and valid, and overcome many practical limitations of more traditional assessment methods. The advancement of these technologies offers unprecedented potential for measuring and understanding some of the most crippling symptoms of some of the most debilitating illnesses known to humankind. PMID:24613984

  17. Computerized Clinical Decision Support: Contributions from 2015

    PubMed Central

    Bouaud, J.

    2016-01-01

    Summary Objective To summarize recent research and select the best papers published in 2015 in the field of computerized clinical decision support for the Decision Support section of the IMIA yearbook. Method A literature review was performed by searching two bibliographic databases for papers related to clinical decision support systems (CDSSs) and computerized provider order entry (CPOE) systems. The aim was to identify a list of candidate best papers from the retrieved papers that were then peer-reviewed by external reviewers. A consensus meeting between the two section editors and the IMIA editorial team was finally conducted to conclude in the best paper selection. Results Among the 974 retrieved papers, the entire review process resulted in the selection of four best papers. One paper reports on a CDSS routinely applied in pediatrics for more than 10 years, relying on adaptations of the Arden Syntax. Another paper assessed the acceptability and feasibility of an important CPOE evaluation tool in hospitals outside the US where it was developed. The third paper is a systematic, qualitative review, concerning usability flaws of medication-related alerting functions, providing an important evidence-based, methodological contribution in the domain of CDSS design and development in general. Lastly, the fourth paper describes a study quantifying the effect of a complex, continuous-care, guideline-based CDSS on the correctness and completeness of clinicians’ decisions. Conclusions While there are notable examples of routinely used decision support systems, this 2015 review on CDSSs and CPOE systems still shows that, despite methodological contributions, theoretical frameworks, and prototype developments, these technologies are not yet widely spread (at least with their full functionalities) in routine clinical practice. Further research, testing, evaluation, and training are still needed for these tools to be adopted in clinical practice and, ultimately, illustrate the benefits that they promise. PMID:27830247

  18. Computed tomographic-based quantification of emphysema and correlation to pulmonary function and mechanics.

    PubMed

    Washko, George R; Criner, Gerald J; Mohsenifar, Zab; Sciurba, Frank C; Sharafkhaneh, Amir; Make, Barry J; Hoffman, Eric A; Reilly, John J

    2008-06-01

    Computed tomographic based indices of emphysematous lung destruction may highlight differences in disease pathogenesis and further enable the classification of subjects with Chronic Obstructive Pulmonary Disease. While there are multiple techniques that can be utilized for such radiographic analysis, there is very little published information comparing the performance of these methods in a clinical case series. Our objective was to examine several quantitative and semi-quantitative methods for the assessment of the burden of emphysema apparent on computed tomographic scans and compare their ability to predict lung mechanics and function. Automated densitometric analysis was performed on 1094 computed tomographic scans collected upon enrollment into the National Emphysema Treatment Trial. Trained radiologists performed an additional visual grading of emphysema on high resolution CT scans. Full pulmonary function test results were available for correlation, with a subset of subjects having additional measurements of lung static recoil. There was a wide range of emphysematous lung destruction apparent on the CT scans and univariate correlations to measures of lung function were of modest strength. No single method of CT scan analysis clearly outperformed the rest of the group. Quantification of the burden of emphysematous lung destruction apparent on CT scan is a weak predictor of lung function and mechanics in severe COPD with no uniformly superior method found to perform this analysis. The CT based quantification of emphysema may augment pulmonary function testing in the characterization of COPD by providing complementary phenotypic information.

  19. CCD-camera-based diffuse optical tomography to study ischemic stroke in preclinical rat models

    NASA Astrophysics Data System (ADS)

    Lin, Zi-Jing; Niu, Haijing; Liu, Yueming; Su, Jianzhong; Liu, Hanli

    2011-02-01

    Stroke, due to ischemia or hemorrhage, is the neurological deficit of cerebrovasculature and is the third leading cause of death in the United States. More than 80 percent of stroke patients are ischemic stroke due to blockage of artery in the brain by thrombosis or arterial embolism. Hence, development of an imaging technique to image or monitor the cerebral ischemia and effect of anti-stoke therapy is more than necessary. Near infrared (NIR) optical tomographic technique has a great potential to be utilized as a non-invasive image tool (due to its low cost and portability) to image the embedded abnormal tissue, such as a dysfunctional area caused by ischemia. Moreover, NIR tomographic techniques have been successively demonstrated in the studies of cerebro-vascular hemodynamics and brain injury. As compared to a fiberbased diffuse optical tomographic system, a CCD-camera-based system is more suitable for pre-clinical animal studies due to its simpler setup and lower cost. In this study, we have utilized the CCD-camera-based technique to image the embedded inclusions based on tissue-phantom experimental data. Then, we are able to obtain good reconstructed images by two recently developed algorithms: (1) depth compensation algorithm (DCA) and (2) globally convergent method (GCM). In this study, we will demonstrate the volumetric tomographic reconstructed results taken from tissuephantom; the latter has a great potential to determine and monitor the effect of anti-stroke therapies.

  20. Computerized tomography magnified bone windows are superior to standard soft tissue windows for accurate measurement of stone size: an in vitro and clinical study.

    PubMed

    Eisner, Brian H; Kambadakone, Avinash; Monga, Manoj; Anderson, James K; Thoreson, Andrew A; Lee, Hang; Dretler, Stephen P; Sahani, Dushyant V

    2009-04-01

    We determined the most accurate method of measuring urinary stones on computerized tomography. For the in vitro portion of the study 24 calculi, including 12 calcium oxalate monohydrate and 12 uric acid stones, that had been previously collected at our clinic were measured manually with hand calipers as the gold standard measurement. The calculi were then embedded into human kidney-sized potatoes and scanned using 64-slice multidetector computerized tomography. Computerized tomography measurements were performed at 4 window settings, including standard soft tissue windows (window width-320 and window length-50), standard bone windows (window width-1120 and window length-300), 5.13x magnified soft tissue windows and 5.13x magnified bone windows. Maximum stone dimensions were recorded. For the in vivo portion of the study 41 patients with distal ureteral stones who underwent noncontrast computerized tomography and subsequently spontaneously passed the stones were analyzed. All analyzed stones were 100% calcium oxalate monohydrate or mixed, calcium based stones. Stones were prospectively collected at the clinic and the largest diameter was measured with digital calipers as the gold standard. This was compared to computerized tomography measurements using 4.0x magnified soft tissue windows and 4.0x magnified bone windows. Statistical comparisons were performed using Pearson's correlation and paired t test. In the in vitro portion of the study the most accurate measurements were obtained using 5.13x magnified bone windows with a mean 0.13 mm difference from caliper measurement (p = 0.6). Measurements performed in the soft tissue window with and without magnification, and in the bone window without magnification were significantly different from hand caliper measurements (mean difference 1.2, 1.9 and 1.4 mm, p = 0.003, <0.001 and 0.0002, respectively). When comparing measurement errors between stones of different composition in vitro, the error for calcium oxalate calculi was significantly different from the gold standard for all methods except bone window settings with magnification. For uric acid calculi the measurement error was observed only in standard soft tissue window settings. In vivo 4.0x magnified bone windows was superior to 4.0x magnified soft tissue windows in measurement accuracy. Magnified bone window measurements were not statistically different from digital caliper measurements (mean underestimation vs digital caliper 0.3 mm, p = 0.4), while magnified soft tissue windows were statistically distinct (mean underestimation 1.4 mm, p = 0.001). In this study magnified bone windows were the most accurate method of stone measurements in vitro and in vivo. Therefore, we recommend the routine use of magnified bone windows for computerized tomography measurement of stones. In vitro the measurement error in calcium oxalate stones was greater than that in uric acid stones, suggesting that stone composition may be responsible for measurement inaccuracies.

  1. Knowledge translation of the American College of Emergency Physicians' clinical policy on syncope using computerized clinical decision support.

    PubMed

    Melnick, Edward R; Genes, Nicholas G; Chawla, Neal K; Akerman, Meredith; Baumlin, Kevin M; Jagoda, Andy

    2010-06-01

    To influence physician practice behavior after implementation of a computerized clinical decision support system (CDSS) based upon the recommendations from the 2007 ACEP Clinical Policy on Syncope. This was a pre-post intervention with a prospective cohort and retrospective controls. We conducted a medical chart review of consecutive adult patients with syncope. A computerized CDSS prompting physicians to explain their decision-making regarding imaging and admission in syncope patients based upon ACEP Clinical Policy recommendations was embedded into the emergency department information system (EDIS). The medical records of 410 consecutive adult patients presenting with syncope were reviewed prior to implementation, and 301 records were reviewed after implementation. Primary outcomes were physician practice behavior demonstrated by admission rate and rate of head computed tomography (CT) imaging before and after implementation. There was a significant difference in admission rate pre- and post-intervention (68.1% vs. 60.5% respectively, p = 0.036). There was no significant difference in the head CT imaging rate pre- and post-intervention (39.8% vs. 43.2%, p = 0.358). There were seven physicians who saw ten or more patients during the pre- and post-intervention. Subset analysis of these seven physicians' practice behavior revealed a slight significant difference in the admission rate pre- and post-intervention (74.3% vs. 63.9%, p = 0.0495) and no significant difference in the head CT scan rate pre- and post-intervention (42.9% vs. 45.4%, p = 0.660). The introduction of an evidence-based CDSS based upon ACEP Clinical Policy recommendations on syncope correlated with a change in physician practice behavior in an urban academic emergency department. This change suggests emergency medicine clinical practice guideline recommendations can be incorporated into the physician workflow of an EDIS to enhance the quality of practice.

  2. Making cognitive decision support work: Facilitating adoption, knowledge and behavior change through QI.

    PubMed

    Weir, Charlene; Brunker, Cherie; Butler, Jorie; Supiano, Mark A

    2017-07-01

    This paper evaluates the role of facilitation in the successful implementation of Computerized Decision Support (CDS). Facilitation processes include education, specialized computerized decision support, and work process reengineering. These techniques, as well as modeling and feedback enhance self-efficacy, which we propose is one of the factors that mediate the effectiveness of any CDS. In this study, outpatient clinics implemented quality improvement (QI) projects focused on improving geriatric care. Quality Improvement is the systematic process of improving quality through continuous measurement and targeted actions. The program, entitled "Advancing Geriatric Education through Quality Improvement" (AGE QI), consisted of a 6-month, QI based, intervention: (1) 2h didactic session, (2) 1h QI planning session, (3) computerized decision support design and implementation, (4) QI facilitation activities, (5) outcome feedback, and (6) 20h of CME. Specifically, we examined the impact of the QI based program on clinician's perceived self-efficacy in caring for older adults and the relationship of implementation support and facilitation on perceived success. The intervention was implemented at 3 institutions, 27 community healthcare system clinics, and 134 providers. This study reports the results of pre/post surveys for the forty-nine clinicians who completed the full CME program. Self-efficacy ratings for specific clinical behaviors related to care of older adults were assessed using a Likert based instrument. Self-ratings of efficacy improved across the following domains (depression, falls, end-of-life, functional status and medication management) and specifically in QI targeted domains and were associated with overall clinic improvements. Published by Elsevier Inc.

  3. Evaluation of a Computerized Clinical Information System (Micromedex).

    PubMed Central

    Lundsgaarde, H. P.; Moreshead, G. E.

    1991-01-01

    This paper summarizes data collected as part of a project designed to identify and assess the technical and organizational problems associated with the implementation and evaluation of a Computerized Clinical Information System (CCIS), Micromedex, in three U.S. Department of Veterans Affairs Medical Centers (VAMCs). The study began in 1987 as a national effort to implement decision support technologies in the Veterans Administration Decentralized Hospital Computer Program (DHCP). The specific objectives of this project were to (1) examine one particular decision support technology, (2) identify the technical and organizational barriers to the implementation of a CCIS in the VA host environment, (3) assess the possible benefits of this system to VA clinicians in terms of therapeutic decision making, and (4) develop new methods for identifying the clinical utility of a computer program designed to provide clinicians with a new information tool. The project was conducted intermittently over a three-year period at three VA medical centers chosen as implementation and evaluation test sites for Micromedex. Findings from the Kansas City Medical Center in Missouri are presented to illustrate some of the technical problems associated with the implementation of a commercial database program in the DHCP host environment, the organizational factors influencing clinical use of the system, and the methods used to evaluate its use. Data from 4581 provider encounters with the CCIS are summarized. Usage statistics are presented to illustrate the methodological possibilities for assessing the "benefits and burdens" of a computerized information system by using an automated collection of user demographics and program audit trails that allow evaluators to monitor user interactions with different segments of the database. PMID:1807583

  4. Evaluation of a Computerized Clinical Information System (Micromedex).

    PubMed

    Lundsgaarde, H P; Moreshead, G E

    1991-01-01

    This paper summarizes data collected as part of a project designed to identify and assess the technical and organizational problems associated with the implementation and evaluation of a Computerized Clinical Information System (CCIS), Micromedex, in three U.S. Department of Veterans Affairs Medical Centers (VAMCs). The study began in 1987 as a national effort to implement decision support technologies in the Veterans Administration Decentralized Hospital Computer Program (DHCP). The specific objectives of this project were to (1) examine one particular decision support technology, (2) identify the technical and organizational barriers to the implementation of a CCIS in the VA host environment, (3) assess the possible benefits of this system to VA clinicians in terms of therapeutic decision making, and (4) develop new methods for identifying the clinical utility of a computer program designed to provide clinicians with a new information tool. The project was conducted intermittently over a three-year period at three VA medical centers chosen as implementation and evaluation test sites for Micromedex. Findings from the Kansas City Medical Center in Missouri are presented to illustrate some of the technical problems associated with the implementation of a commercial database program in the DHCP host environment, the organizational factors influencing clinical use of the system, and the methods used to evaluate its use. Data from 4581 provider encounters with the CCIS are summarized. Usage statistics are presented to illustrate the methodological possibilities for assessing the "benefits and burdens" of a computerized information system by using an automated collection of user demographics and program audit trails that allow evaluators to monitor user interactions with different segments of the database.

  5. Brief cognitive and behavioral screening in children with new-onset epilepsy: a pilot feasibility trial.

    PubMed

    Triplett, Regina L; Asato, Miya R

    2015-01-01

    Minimal work has used psychometrically robust measures in a systematic fashion to identify and monitor children at risk for cognitive and behavioral comorbidities in current epilepsy care. We piloted a computerized cognitive battery and behavioral questionnaire for children with newly diagnosed epilepsy to determine clinical feasibility and acceptability to parents and patients. We recruited medication-naïve children (ages 8-17 years) with recent-onset seizures and typical developmental history from an outpatient child neurology clinic. Children completed the CNS Vital Signs computerized battery, whereas parents completed the Strengths and Difficulties Questionnaire. Post-test interviews with parents and patients were completed regarding the acceptability of the assessment procedures. Forty-four families were eligible, and 39 agreed to participate (89%). All assessments were completed in less than 45 minutes. Parents rated testing in clinic as convenient and important, expressing strong interest in the cognitive and behavioral impact of epilepsy and medication. Children also rated the testing procedure as acceptable and agreed that they would recommend it to peers. Our brief battery was tolerated and well received by children and their parents. Computerized testing of children along with a parent questionnaire is a psychometrically viable approach that is acceptable to families. Our protocol is time efficient for clinical use with the potential to detect early cognitive and behavioral difficulties related to epilepsy. Ongoing longitudinal study will provide further information regarding the success of our screening methods in monitoring for disease- or treatment-related changes. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Electronic information and clinical decision support for prescribing: state of play in Australian general practice

    PubMed Central

    Robertson, Jane; Moxey, Annette J; Newby, David A; Gillies, Malcolm B; Williamson, Margaret; Pearson, Sallie-Anne

    2011-01-01

    Background. Investments in eHealth worldwide have been mirrored in Australia, with >90% of general practices computerized. Recent eHealth incentives promote the use of up to date electronic information sources relevant to general practice with flexibility in mode of access. Objective. To determine GPs’ access to and use of electronic information sources and computerized clinical decision support systems (CDSSs) for prescribing. Methods. Semi-structured interviews were conducted with 18 experienced GPs and nine GP trainees in New South Wales, Australia in 2008. A thematic analysis of interview transcripts was undertaken. Results. Information needs varied with clinical experience, and people resources (specialists, GP peers and supervisors for trainees) were often preferred over written formats. Experienced GPs used a small number of electronic resources and accessed them infrequently. Familiarity from training and early clinical practice and easy access were dominant influences on resource use. Practice time constraints meant relevant information needed to be readily accessible during consultations, requiring integration or direct access from prescribing software. Quality of electronic resource content was assumed and cost a barrier for some GPs. Conclusions. The current Australian practice incentives do not prescribe which information resources GPs should use. Without integration into practice computing systems, uptake and routine use seem unlikely. CDSS developments must recognize the time pressures of practice, preference for integration and cost concerns. Minimum standards are required to ensure that high-quality information resources are integrated and regularly updated. Without standards, the anticipated benefits of computerization on patient safety and health outcomes will be uncertain. PMID:21109619

  7. Browsing Software of the Visible Korean Data Used for Teaching Sectional Anatomy

    ERIC Educational Resources Information Center

    Shin, Dong Sun; Chung, Min Suk; Park, Hyo Seok; Park, Jin Seo; Hwang, Sung Bae

    2011-01-01

    The interpretation of computed tomographs (CTs) and magnetic resonance images (MRIs) to diagnose clinical conditions requires basic knowledge of sectional anatomy. Sectional anatomy has traditionally been taught using sectioned cadavers, atlases, and/or computer software. The computer software commonly used for this subject is practical and…

  8. A computerized faculty time-management system in an academic family medicine department.

    PubMed

    Daugird, Allen J; Arndt, Jane E; Olson, P Richard

    2003-02-01

    The authors describe the development, implementation, and evaluation of a computerized faculty time-management system (FTMS) in the Department of Family Medicine at the University of North Carolina-Chapel Hill. The FTMS is presented as an integrated set of computerized spreadsheets used annually to allocate faculty time across all mission activities of the department. It was first implemented in 1996 and has been continuously developed since then. An iterative approach has been used to gain consensus among faculty about time resources needed for various tasks of all missions of the department. These time-resource assumptions are used in the computerized system. Faculty time is allocated annually by the department vice chair in negotiation with individual faculty, making sure that the activities planned do not exceed the work time each faculty member has available for the year. During this process, faculty preferences are balanced against department aggregate needs to meet mission commitments and obligations. The authors describe how the computerized FTMS is used for faculty time management and career development, department planning, budget planning, clinical scheduling, and mission cost accounting. They also describe barriers and potential abuses and the challenge of building an organizational culture willing to discuss faculty time openly and committed to developing a system perceived as fair and accurate. The spreadsheet file is available free from the authors for use in other departments.

  9. Clinical Information Systems – From Yesterday to Tomorrow

    PubMed Central

    2016-01-01

    Summary Objectives To review the history of clinical information systems over the past twenty-five years and project anticipated changes to those systems over the next twenty-five years. Methods Over 250 Medline references about clinical information systems, quality of patient care, and patient safety were reviewed. Books, Web resources, and the author’s personal experience with developing the HELP system were also used. Results There have been dramatic improvements in the use and acceptance of clinical computing systems and Electronic Health Records (EHRs), especially in the United States. Although there are still challenges with the implementation of such systems, the rate of progress has been remarkable. Over the next twenty-five years, there will remain many important opportunities and challenges. These opportunities include understanding complex clinical computing issues that must be studied, understood and optimized. Dramatic improvements in quality of care and patient safety must be anticipated as a result of the use of clinical information systems. These improvements will result from a closer involvement of clinical informaticians in the optimization of patient care processes. Conclusions Clinical information systems and computerized clinical decision support have made contributions to medicine in the past. Therefore, by using better medical knowledge, optimized clinical information systems, and computerized clinical decision, we will enable dramatic improvements in both the quality and safety of patient care in the next twenty-five years. PMID:27362589

  10. Endocrine abnormalities in critical care patients with moderate-to-severe head trauma: incidence, pattern and predisposing factors.

    PubMed

    Dimopoulou, Ioanna; Tsagarakis, Stylianos; Theodorakopoulou, Maria; Douka, Evangelia; Zervou, Maria; Kouyialis, Andreas T; Thalassinos, Nikolaos; Roussos, Charis

    2004-06-01

    To investigate the incidence and type of endocrine abnormalities in critical care patients with traumatic brain injury (TBI) and to examine their relationships to possible predisposing factors. Prospective study. General intensive care unit in a university hospital. Thirty-four TBI patients (27 men, 7 women), having a mean age of 37+/-16 years, were studied after weaning from mechanical ventilation. Baseline endocrine assessment was carried out by measuring cortisol, corticotropin, dehydroepiandrosterone sulfate, free thyroxine, thyrotropin (TSH), testosterone, oestradiol, follicle stimulating hormone (FSH), luteinizing hormone, prolactin, growth hormone and insulin-like growth factor I. Dynamic evaluation was performed by human corticotropin releasing hormone and growth hormone releasing hormone in all patients. Male patients underwent additional investigation with gonadotropin-releasing hormone. Severity of neurological derangement was graded according to Glasgow Coma Scale (GCS), Marshall Computerized Tomographic Classification and intracranial pressure (ICP) levels. Eighteen of the 34 patients (53%) had an abnormal result in at least one hormonal axis tested, with cortisol hyporesponsiveness and gonadal dysfunction being equally common, affecting 24% of patients. Endocrine abnormalities were associated with a higher brain CT-scan classification score ( p=0.02). The GCS on admission correlated positively with baseline FSH (r=0.37, p=0.03), peak FSH (r=0.41, p=0.03), testosterone (r=0.44, p=0.02) and TSH (r=0.39, p=0.03). There were no relations between ICP(max) and any baseline or dynamic hormone measurements. Patients with TBI receiving critical care show changes in their neuroendocrine responses, which depend upon clinical and radiological measures of head injury severity. Most common abnormalities include cortisol hyporesponsiveness and hypogonadism.

  11. Compensatory Hypertrophy After Living Donor Nephrectomy.

    PubMed

    Chen, K W; Wu, M W F; Chen, Z; Tai, B C; Goh, Y S B; Lata, R; Vathsala, A; Tiong, H Y

    2016-04-01

    Previous studies have shown that kidney volume enhances the estimation of glomerular filtration rate (eGFR) in kidney donors. This study aimed to describe the phenomenon of compensatory hypertrophy after donor nephrectomy as measured on computerized tomographic (CT) scans. An institutional Domain Specific Review Board (DSRB)-approved study involved approaching kidney donors to have a follow up CT scan from 6 months to 1 year after surgery; 29 patients participated; 55% were female. Clinical chart review was performed, and the patient's remaining kidney volume was measured before and after surgery based on CT scans. eGFR was determined with the use of the Modification of Diet in Renal Disease equation. Mean parenchymal volume of the remaining kidney for this population (mean age, 44.3 ± 8.5 y) was 204.7 ± 82.5 cc before surgery and 250.5 ± 113.3 cc after donor nephrectomy. Compensatory hypertrophy occurred in 79.3% of patients (n = 23). Mean increase in remaining kidney volume was 22.4 ± 23.2% after donor nephrectomy in healthy individuals. Over a median follow-up of 52.9 ± 19.8 months, mean eGFR was 68.9 ± 12.4 mL/min/1.73 m(2), with 24.1% of patients (n = 7) in chronic kidney disease grade 3. Absolute and relative change in kidney volume was not associated with sex, race, surgical approach, or background of hypertension (P = NS). There was a trend of decreased hypertrophy with increasing age (P = .5; Spearman correlation, -0.12). In healthy kidney donors, compensatory hypertrophy of the remaining kidney occurs in 79.3% of the patients, with an average increment of about 22.4%. Older patients may have a blunted compensatory hypertrophy response after surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Outpatients flow management and ophthalmic electronic medical records system in university hospital using Yahgee Document View.

    PubMed

    Matsuo, Toshihiko; Gochi, Akira; Hirakawa, Tsuyoshi; Ito, Tadashi; Kohno, Yoshihisa

    2010-10-01

    General electronic medical records systems remain insufficient for ophthalmology outpatient clinics from the viewpoint of dealing with many ophthalmic examinations and images in a large number of patients. Filing systems for documents and images by Yahgee Document View (Yahgee, Inc.) were introduced on the platform of general electronic medical records system (Fujitsu, Inc.). Outpatients flow management system and electronic medical records system for ophthalmology were constructed. All images from ophthalmic appliances were transported to Yahgee Image by the MaxFile gateway system (P4 Medic, Inc.). The flow of outpatients going through examinations such as visual acuity testing were monitored by the list "Ophthalmology Outpatients List" by Yahgee Workflow in addition to the list "Patients Reception List" by Fujitsu. Patients' identification number was scanned with bar code readers attached to ophthalmic appliances. Dual monitors were placed in doctors' rooms to show Fujitsu Medical Records on the left-hand monitor and ophthalmic charts of Yahgee Document on the right-hand monitor. The data of manually-inputted visual acuity, automatically-exported autorefractometry and non-contact tonometry on a new template, MaxFile ED, were again automatically transported to designated boxes on ophthalmic charts of Yahgee Document. Images such as fundus photographs, fluorescein angiograms, optical coherence tomographic and ultrasound scans were viewed by Yahgee Image, and were copy-and-pasted to assigned boxes on the ophthalmic charts. Ordering such as appointments, drug prescription, fees and diagnoses input, central laboratory tests, surgical theater and ward room reservations were placed by functions of the Fujitsu electronic medical records system. The combination of the Fujitsu electronic medical records and Yahgee Document View systems enabled the University Hospital to examine the same number of outpatients as prior to the implementation of the computerized filing system.

  13. Spontaneous cleft palate in a newborn gorilla (Gorilla gorilla gorilla).

    PubMed

    Siebert, J R; Williams, B; Collins, D; Winkler, L A; Swindler, D R

    1998-09-01

    We report the first case of cleft palate in a newborn male gorilla (Gorilla gorilla gorilla). The full-term infant was born to clinically healthy, wild-caught parents and survived 5 days. Autopsy disclosed a unilateral cleft palate, moderate scalp hemorrhage (birth versus postnatal trauma), cerebral edema, and a sterile fibrin vegetation in the heart. The palate was also shorter and narrower than expected, and the biorbital breadth was reduced; otherwise, growth and development appeared normal. Standard cranial and intraoral radiographs and three-dimensional reconstructions of computerized tomographic (CT) scans provided thorough and noninvasive methods of studying the craniofacial complex and extracranial skeleton. By this technique, major findings were: intact premaxilla, interpremaxillary, and premaxillary/maxillary sutures; intramaxillary cleft with ipsilateral choanal atresia; mildly asymmetric inferior turbinates; and normal nasal septum and vomer. Except for choanal atresia, cleft palate was not associated with other major craniofacial or extracranial anomalies in this case. Choanal atresia has been observed at times with cleft palate, but to our knowledge, the association has not been reported in nonhuman primates. Cleft palate, with or without cleft lip, has been recognized in a variety of nonhuman primates, including the lemur, marmoset, tamarin, squirrel monkey, and macaque. Some occurrences are spontaneous, while others are syndromic and/or arise from genetic or teratogenic influences. Each mode of presentation is poorly understood in nonhuman primates, but in this case, the absence of relevant environmental or parental history suggests that the occurrence was spontaneous. Anatomic studies of nonhuman primates are particularly valuable when they involve endangered species and will hopefully increase our understanding of the pathogenesis and etiology of congenital disorders, as well as other relationships between nonhuman primates and humans.

  14. Computed tomography in cases of coccidioidal meningitis, with clinical correlation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shetter, A.G.; Fischer, D.W.; Flom, R.A.

    1985-06-01

    Cranial computed tomographic (CT) scans of 22 patients with coccidioidal meningitis were reviewed and their clinical course was analyzed. Abnormalities of the ventricular system or the basilar cisterns or both were present in 16 instances. Although it is not a definitive diagnostic tool, the CT scan is helpful in suggesting a diagnosis of coccidioidal meningitis and in predicting the prognosis of patients affected by the disease. 19 references, 4 figures, 2 tables.

  15. Evaluation of an ontology-based system for computerized cognitive rehabilitation.

    PubMed

    Alloni, Anna; Quaglini, Silvana; Panzarasa, Silvia; Sinforiani, Elena; Bernini, Sara

    2018-07-01

    This paper describes the results of a randomized clinical trial about the effectiveness of a computerized rehabilitation treatment on a sample of 31 patients affected by Parkinson disease. Computerized exercises were administered by the therapists to the intervention group (n = 17) through the CoRe tool, which automatically generates a big variety of exercises leveraging on a stimuli set (words, sounds and images) organized into a dedicated ontology. A battery of standard neuropsychological tests was performed for patients' assessment at baseline, after the treatment (that lasted 1 month), and after 6 months from the treatment stop. The control group underwent a sham intervention. Results show a statistically significant clinical benefit from computerized rehabilitation with respect to sham treatment. For the intervention group, response time and response accuracy were integrated into a weighted score that accounts also for the specific cognitive burden of each exercise. Differently from the control group, the majority of patients in the intervention group showed an improvement in that score, more marked in the first week of treatment, and which lasts for the entire treatment period, which could account both for a quick learning effect and for an improvement of cognitive conditions. Good usability of CoRe, already observed in previous studies, was confirmed by the present trial, where the percentage of protocol completion in the intervention group is very high (all but one patient are above 90%). The CoRe system showed to be effective to improve some cognitive abilities in patients with Parkinson disease. However, after the end of the training, the benefit is hardly maintained over time. These findings support the implementation of CoRe in the clinical routine and the continuation of the treatment after discharge through the use of a homecare version of the system. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Assessment of readiness for clinical decision support to aid laboratory monitoring of immunosuppressive care at U.S. liver transplant centers.

    PubMed

    Jacobs, J; Weir, C; Evans, R S; Staes, C

    2014-01-01

    Following liver transplantation, patients require lifelong immunosuppressive care and monitoring. Computerized clinical decision support (CDS) has been shown to improve post-transplant immunosuppressive care processes and outcomes. The readiness of transplant information systems to implement computerized CDS to support post-transplant care is unknown. a) Describe the current clinical information system functionality and manual and automated processes for laboratory monitoring of immunosuppressive care, b) describe the use of guidelines that may be used to produce computable logic and the use of computerized alerts to support guideline adherence, and c) explore barriers to implementation of CDS in U.S. liver transplant centers. We developed a web-based survey using cognitive interviewing techniques. We surveyed 119 U.S. transplant programs that performed at least five liver transplantations per year during 2010-2012. Responses were summarized using descriptive analyses; barriers were identified using qualitative methods. Respondents from 80 programs (67% response rate) completed the survey. While 98% of programs reported having an electronic health record (EHR), all programs used paper-based manual processes to receive or track immunosuppressive laboratory results. Most programs (85%) reported that 30% or more of their patients used external laboratories for routine testing. Few programs (19%) received most external laboratory results as discrete data via electronic interfaces while most (80%) manually entered laboratory results into the EHR; less than half (42%) could integrate internal and external laboratory results. Nearly all programs had guidelines regarding pre-specified target ranges (92%) or testing schedules (97%) for managing immunosuppressive care. Few programs used computerized alerting to notify transplant coordinators of out-of-range (27%) or overdue laboratory results (20%). Use of EHRs is common, yet all liver transplant programs were largely dependent on manual paper-based processes to monitor immunosuppression for post-liver transplant patients. Similar immunosuppression guidelines provide opportunities for sharing CDS once integrated laboratory data are available.

  17. Computerization of Mental Health Integration Complexity Scores at Intermountain Healthcare

    PubMed Central

    Oniki, Thomas A.; Rodrigues, Drayton; Rahman, Noman; Patur, Saritha; Briot, Pascal; Taylor, David P.; Wilcox, Adam B.; Reiss-Brennan, Brenda; Cannon, Wayne H.

    2014-01-01

    Intermountain Healthcare’s Mental Health Integration (MHI) Care Process Model (CPM) contains formal scoring criteria for assessing a patient’s mental health complexity as “mild,” “medium,” or “high” based on patient data. The complexity score attempts to assist Primary Care Physicians in assessing the mental health needs of their patients and what resources will need to be brought to bear. We describe an effort to computerize the scoring. Informatics and MHI personnel collaboratively and iteratively refined the criteria to make them adequately explicit and reflective of MHI objectives. When tested on retrospective data of 540 patients, the clinician agreed with the computer’s conclusion in 52.8% of the cases (285/540). We considered the analysis sufficiently successful to begin piloting the computerized score in prospective clinical care. So far in the pilot, clinicians have agreed with the computer in 70.6% of the cases (24/34). PMID:25954401

  18. A Real Time Interface Between a Computerized Physician Order Entry System and the Computerized ICU Medication Administration Record

    PubMed Central

    Chen, Jeannie; Shabot, M. Michael; LoBue, Mark

    2003-01-01

    Prior attempts to interface ICU Clinical Information Systems (CIS) to Pharmacy systems have been less than successful. The major problem is that in ICUs, medications frequently have to be administered and charted in the CIS Medication Administration Record (MAR) before pharmacists can enter them into the Pharmacy system. When the Pharmacy system belatedly sends medication orders to the CIS MAR, this may create duplicate entries for medications that ICU nurses have had to enter manually to chart doses actually given. The authors have implemented a real time interface between a Computerized Physician Order Entry (CPOE) system and a CIS operating in ten ICUs that solves this problem. The interface transfers new medication orders including order details and alerts directly to the CIS Medication Administration Record (MAR), where they are immediately available for nurse charting. PMID:14728315

  19. Education in the Workplace for the Physician: Clinical Management States as an Organizing Framework.

    ERIC Educational Resources Information Center

    Greenes, Robert A.

    2000-01-01

    Trends in health information technology include (1) improved access to patient care information; (2) methods for patient-doctor interaction and decision making; (3) computerized practice guidelines; and (4) the concept of patients being in clinical management states (CMS). Problem-specific environments and CMS-related resources should be the focus…

  20. Osteochondroma of the mandibular condyle: a classification system based on computed tomographic appearances.

    PubMed

    Chen, Min-jie; Yang, Chi; Qiu, Ya-ting; Zhou, Qin; Huang, Dong; Shi, Hui-min

    2014-09-01

    The objectives of this study were to introduce the classification of osteochondroma of the mandibular condyle based on computed tomographic images and to present our treatment experiences. From January 2002 and December 2012, a total of 61 patients with condylar osteochondroma were treated in our division. Both clinical and radiologic aspects were reviewed. The average follow-up period was 24.3 months with a range of 6 to 120 months. Two types of condylar osteochondroma were presented: type 1 (protruding expansion) in 50 patients (82.0%) and type 2 (globular expansion) in 11 patients (18.0%). Type 1 condylar osteochondroma presented 5 forms: anterior/anteromedial (58%), posterior/posteromedial (6%), medial (16%), lateral (6%), and gigantic (14%). Local resection was performed on patients with type 1 condylar osteochondroma. Subtotal condylectomy/total condylectomy using costochondral graft reconstruction with/without orthognathic surgeries was performed on patients with type 2 condylar osteochondroma. During the follow-up period, tumor reformation, condyle absorption, and new deformity were not detected. The patients almost reattained facial symmetry. Preoperative classification based on computed tomographic images will help surgeons to choose the suitable surgical procedure to treat the condylar osteochondroma.

  1. Arterial Obstruction on Computed Tomographic or Magnetic Resonance Angiography and Response to Intravenous Thrombolytics in Ischemic Stroke.

    PubMed

    Mair, Grant; von Kummer, Rüdiger; Adami, Alessandro; White, Philip M; Adams, Matthew E; Yan, Bernard; Demchuk, Andrew M; Farrall, Andrew J; Sellar, Robin J; Sakka, Eleni; Palmer, Jeb; Perry, David; Lindley, Richard I; Sandercock, Peter A G; Wardlaw, Joanna M

    2017-02-01

    Computed tomographic angiography and magnetic resonance angiography are used increasingly to assess arterial patency in patients with ischemic stroke. We determined which baseline angiography features predict response to intravenous thrombolytics in ischemic stroke using randomized controlled trial data. We analyzed angiograms from the IST-3 (Third International Stroke Trial), an international, multicenter, prospective, randomized controlled trial of intravenous alteplase. Readers, masked to clinical, treatment, and outcome data, assessed prerandomization computed tomographic angiography and magnetic resonance angiography for presence, extent, location, and completeness of obstruction and collaterals. We compared angiography findings to 6-month functional outcome (Oxford Handicap Scale) and tested for interactions with alteplase, using ordinal regression in adjusted analyses. We also meta-analyzed all available angiography data from other randomized controlled trials of intravenous thrombolytics. In IST-3, 300 patients had prerandomization angiography (computed tomographic angiography=271 and magnetic resonance angiography=29). On multivariable analysis, more extensive angiographic obstruction and poor collaterals independently predicted poor outcome (P<0.01). We identified no significant interaction between angiography findings and alteplase effect on Oxford Handicap Scale (P≥0.075) in IST-3. In meta-analysis (5 trials of alteplase or desmoteplase, including IST-3, n=591), there was a significantly increased benefit of thrombolytics on outcome (odds ratio>1 indicates benefit) in patients with (odds ratio, 2.07; 95% confidence interval, 1.18-3.64; P=0.011) versus without (odds ratio, 0.88; 95% confidence interval, 0.58-1.35; P=0.566) arterial obstruction (P for interaction 0.017). Intravenous thrombolytics provide benefit to stroke patients with computed tomographic angiography or magnetic resonance angiography evidence of arterial obstruction, but the sample was underpowered to demonstrate significant treatment benefit or harm among patients with apparently patent arteries. URL: http://www.isrctn.com. Unique identifier: ISRCTN25765518. © 2016 The Authors.

  2. Coronary Plaque Morphology and the Anti-Inflammatory Impact of Atorvastatin: A Multicenter 18F-Fluorodeoxyglucose Positron Emission Tomographic/Computed Tomographic Study.

    PubMed

    Singh, Parmanand; Emami, Hamed; Subramanian, Sharath; Maurovich-Horvat, Pal; Marincheva-Savcheva, Gergana; Medina, Hector M; Abdelbaky, Amr; Alon, Achilles; Shankar, Sudha S; Rudd, James H F; Fayad, Zahi A; Hoffmann, Udo; Tawakol, Ahmed

    2016-12-01

    Nonobstructive coronary plaques manifesting high-risk morphology (HRM) associate with an increased risk of adverse clinical cardiovascular events. We sought to test the hypothesis that statins have a greater anti-inflammatory effect within coronary plaques containing HRM. In this prospective multicenter study, 55 subjects with or at high risk for atherosclerosis underwent 18 F-fluorodeoxyglucose positron emission tomographic/computed tomographic imaging at baseline and after 12 weeks of treatment with atorvastatin. Coronary arterial inflammation ( 18 F-fluorodeoxyglucose uptake, expressed as target-to-background ratio) was assessed in the left main coronary artery (LMCA). While blinded to the PET findings, contrast-enhanced computed tomographic angiography was performed to characterize the presence of HRM (defined as noncalcified or partially calcified plaques) in the LMCA. Arterial inflammation (target-to-background ratio) was higher in LMCA segments with HRM than those without HRM (mean±SEM: 1.95±0.43 versus 1.67±0.32 for LMCA with versus without HRM, respectively; P=0.04). Moreover, atorvastatin treatment for 12 weeks reduced target-to-background ratio more in LMCA segments with HRM than those without HRM (12 week-baseline Δtarget-to-background ratio [95% confidence interval]: -0.18 [-0.35 to -0.004] versus 0.09 [-0.06 to 0.26]; P=0.02). Furthermore, this relationship between coronary plaque morphology and change in LMCA inflammatory activity remained significant after adjusting for baseline low-density lipoprotein and statin dose (β=-0.27; P=0.038). In this first study to evaluate the impact of statins on coronary inflammation, we observed that the anti-inflammatory impact of statins is substantially greater within coronary plaques that contain HRM features. These findings suggest an additional mechanism by which statins disproportionately benefit individuals with more advanced atherosclerotic disease. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00703261. © 2016 The Authors.

  3. Murder, insanity, and medical expert witnesses.

    PubMed

    Ciccone, J R

    1992-06-01

    Recent advances in the ability to study brain anatomy and function and attempts to link these findings with human behavior have captured the attention of the legal system. This had led to the increasing use of the "neurological defense" to support a plea of not guilty by reason of insanity. This article explores the history of the insanity defense and explores the role of the medical expert witnesses in integrating clinical and laboratory findings, eg, computed tomographic scans, magnetic resonance scans, and single-photon emission computed tomographic scans. Three cases involving murder and brain dysfunction are discussed: the first case involves a subarachnoid hemorrhage resulting in visual perceptual and memory impairment; the second case, a diagnosis of Alzheimer's disease; and the third case, the controverted diagnosis of complex partial seizures in a serial killer.

  4. How does electromagnetic navigation stack up against infrared navigation in minimally invasive total knee arthroplasties?

    PubMed

    Lionberger, David R; Weise, Jennifer; Ho, David M; Haddad, John L

    2008-06-01

    Forty-six primary total knee arthroplasties were performed using either an electromagnetic (EM) or infrared (IR) navigation system. In this IRB-approved study, patients were evaluated clinically and for accuracy using spiral computed tomographic imaging and 36-in standing radiographs. Although EM navigation was subject to metal interference, it was not as drastic as line-of-sight interference with IR navigation. Mechanical alignment was ideal in 92.9% of EM and 90.0% of IR cases based on spiral computed tomographic imaging and 100% of EM and 95% of IR cases based on x-ray. Individual measurements of component varus/valgus and sagittal measurements showed EM to be equivalent to IR, with both systems producing subdegree accuracy in 95% of the readings.

  5. Development of a Computerized Adaptive Test for Anxiety Based on the Dutch-Flemish Version of the PROMIS Item Bank.

    PubMed

    Flens, Gerard; Smits, Niels; Terwee, Caroline B; Dekker, Joost; Huijbrechts, Irma; Spinhoven, Philip; de Beurs, Edwin

    2017-12-01

    We used the Dutch-Flemish version of the USA PROMIS adult V1.0 item bank for Anxiety as input for developing a computerized adaptive test (CAT) to measure the entire latent anxiety continuum. First, psychometric analysis of a combined clinical and general population sample ( N = 2,010) showed that the 29-item bank has psychometric properties that are required for a CAT administration. Second, a post hoc CAT simulation showed efficient and highly precise measurement, with an average number of 8.64 items for the clinical sample, and 9.48 items for the general population sample. Furthermore, the accuracy of our CAT version was highly similar to that of the full item bank administration, both in final score estimates and in distinguishing clinical subjects from persons without a mental health disorder. We discuss the future directions and limitations of CAT development with the Dutch-Flemish version of the PROMIS Anxiety item bank.

  6. Validation of an electronic surveillance system for acute lung injury.

    PubMed

    Herasevich, Vitaly; Yilmaz, Murat; Khan, Hasrat; Hubmayr, Rolf D; Gajic, Ognjen

    2009-06-01

    Early detection of acute lung injury (ALI) is essential for timely implementation of evidence-based therapies and enrollment into clinical trials. We aimed to determine the accuracy of computerized syndrome surveillance for detection of ALI in hospitalized patients and compare it with routine clinical assessment. Using a near-real time copy of the electronic medical records, we developed and validated a custom ALI electronic alert (ALI "sniffer") based on the European-American Consensus Conference Definition and compared its performance against provider-derived documentation. A total of 3,795 consecutive critically ill patients admitted to nine multidisciplinary intensive care units (ICUs) of a tertiary care teaching institution were included. ALI developed in 325 patients and was recognized by bedside clinicians in only 86 (26.5%). Under-recognition of ALI was associated with not implementing protective mechanical ventilation (median tidal volumes of 9.2 vs. 8.0 ml/kg predicted body weight, P < 0.001). ALI "sniffer" demonstrated excellent sensitivity of 96% (95% CI 94-98) and moderate specificity of 89% (95% CI 88-90) with a positive predictive value ranging from 24% (95% CI 13-40) in the heart-lung transplant ICU to 64% (95% CI 55-71) in the medical ICU. The computerized surveillance system accurately identifies critically ill patients who develop ALI syndrome. Since the lack of ALI recognition is a barrier to the timely implementation of best practices and enrollment into research studies, computerized syndrome surveillance could be a useful tool to enhance patient safety and clinical research.

  7. Computer versus paper system for recognition and management of sepsis in surgical intensive care.

    PubMed

    Croft, Chasen A; Moore, Frederick A; Efron, Philip A; Marker, Peggy S; Gabrielli, Andrea; Westhoff, Lynn S; Lottenberg, Lawrence; Jordan, Janeen; Klink, Victoria; Sailors, R Matthew; McKinley, Bruce A

    2014-02-01

    A system to provide surveillance, diagnosis, and protocolized management of surgical intensive care unit (SICU) sepsis was undertaken as a performance improvement project. A system for sepsis management was implemented for SICU patients using paper followed by a computerized system. The hypothesis was that the computerized system would be associated with improved process and outcomes. A system was designed to provide early recognition and guide patient-specific management of sepsis including (1) modified early warning signs-sepsis recognition score (MEWS-SRS; summative point score of ranges of vital signs, mental status, white blood cell count; after every 4 hours) by bedside nurse; (2) suspected site assessment (vascular access, lung, abdomen, urinary tract, soft tissue, other) at bedside by physician or extender; (3) sepsis management protocol (replicable, point-of-care decisions) at bedside by nurse, physician, and extender. The system was implemented first using paper and then a computerized system. Sepsis severity was defined using standard criteria. In January to May 2012, a paper system was used to manage 77 consecutive sepsis encounters (3.9 ± 0.5 cases per week) in 65 patients (77% male; age, 53 ± 2 years). In June to December 2012, a computerized system was used to manage 132 consecutive sepsis encounters (4.4 ± 0.4 cases per week) in 119 patients (63% male; age, 58 ± 2 years). MEWS-SRS elicited 683 site assessments, and 201 had sepsis diagnosis and protocol management. The predominant site of infection was abdomen (paper, 58%; computer, 53%). Recognition of early sepsis tended to occur more using the computerized system (paper, 23%; computer, 35%). Hospital mortality rate for surgical ICU sepsis (paper, 20%; computer, 14%) was less with the computerized system. A computerized sepsis management system improves care process and outcome. Early sepsis is recognized and managed with greater frequency compared with severe sepsis or septic shock. The system has a beneficial effect as a clinical standard of care for SICU patients. Therapeutic study, level III.

  8. Anisakiasis presenting to the ED: clinical manifestations, time course, hematologic tests, computed tomographic findings, and treatment.

    PubMed

    Takabayashi, Takeshi; Mochizuki, Toshiaki; Otani, Norio; Nishiyama, Kei; Ishimatsu, Shinichi

    2014-12-01

    The prevalence of anisakiasis is rare in the United States and Europe compared with that in Japan, with few reports of its presentation in the emergency department (ED). This study describes the clinical, hematologic, computed tomographic (CT) characteristics, and treatment in gastric and small intestinal anisakiasis patients in the ED. We retrospectively reviewed the data of 83 consecutive anisakiasis presentations in our ED between 2003 and 2012. Gastric anisakiasis was endoscopically diagnosed with the Anisakis polypide. Small intestinal anisakiasis was diagnosed based on both hematologic (Anisakis antibody) and CT findings. Of the 83 cases, 39 had gastric anisakiasis and 44 had small intestinal anisakiasis based on our diagnostic criteria. Although all patients had abdominal pain, the gastric anisakiasis group developed symptoms significantly earlier (peaking within 6 hours) than the small intestinal anisakiasis group (peaking within 48 hours), and fewer patients with gastric anisakiasis needed admission therapy (5% vs 57%, P<.01). All patients in the gastric and 40 (91%) in the small intestinal anisakiasis group had a history of raw seafood ingestion. Computed tomographic findings revealed edematous wall thickening in all patients, and ascites and phlegmon of the mesenteric fat were more frequently observed in the small intestinal anisakiasis group. In the ED, early and accurate diagnosis of anisakiasis is important to treat and explain to the patient, and diagnosis can be facilitated by a history of raw seafood ingestion, evaluation of the time-to-symptom development, and classic CT findings. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. An Analysis of the Need for a Whole-Body CT Scanner at US Darnall Army Community Hospital

    DTIC Science & Technology

    1980-05-01

    TASK IWORK UNIT ELEMENT NO. I NO.JC NO. rSSION NO. Ij6T’,WAM ’"Aa1W% A WHOLE BODY CT SCANNER AT DARNALL ARMY COMUNITY HOSPITAL 16PTR3OAL tUTHOR(S)* a...computerized axial tomography or CT. Computerized tomography experiments "were conducted by Godfrey Hounsfield at Central Research Laboratories, EMI, Ltd. in...remained the same, with clinical and nursing unit facilities to support a one division post. Presently, Fort Hood is the home of the III US Army Corps, the

  10. Duke Data Bank

    NASA Technical Reports Server (NTRS)

    1979-01-01

    NASA computerized image processing techniques are an integral part of a cardiovascular data bank at Duke University Medical Center. Developed by Dr. C. F. Starmer and colleagues at Duke, the data bank documents the Center's clinical experience with more than 4,000 heart patients as an aid to diagnosis and treatment of heart disease. Data is stored in a computerized system that allows a physician to summon detailed records of former patients whose medical profiles are similar to those of a new patient. A video display (photo) and printed report shows prognostic information for the new patient based on similar past experience.

  11. Electronic Chemotherapy Order Entry: A Major Cancer Center's Implementation

    PubMed Central

    Sklarin, Nancy T.; Granovsky, Svetlana; O'Reilly, Eileen M.; Zelenetz, Andrew D.

    2011-01-01

    Implementation of a computerized provider order entry system for complex chemotherapy regimens at a large cancer center required intense effort from a multidisciplinary team of clinical and systems experts with experience in all facets of the chemotherapy process. The online tools had to resemble the paper forms used at the time and parallel the successful established process as well as add new functionality. Close collaboration between the institution and the vendor was necessary. This article summarizes the institutional efforts, challenges, and collaborative processes that facilitated universal chemotherapy computerized electronic order entry across multiple sites during a period of several years. PMID:22043182

  12. Electronic Chemotherapy Order Entry: A Major Cancer Center's Implementation.

    PubMed

    Sklarin, Nancy T; Granovsky, Svetlana; O'Reilly, Eileen M; Zelenetz, Andrew D

    2011-07-01

    Implementation of a computerized provider order entry system for complex chemotherapy regimens at a large cancer center required intense effort from a multidisciplinary team of clinical and systems experts with experience in all facets of the chemotherapy process. The online tools had to resemble the paper forms used at the time and parallel the successful established process as well as add new functionality. Close collaboration between the institution and the vendor was necessary. This article summarizes the institutional efforts, challenges, and collaborative processes that facilitated universal chemotherapy computerized electronic order entry across multiple sites during a period of several years.

  13. Clinical results of computerized tomography-based simulation with laser patient marking.

    PubMed

    Ragan, D P; Forman, J D; He, T; Mesina, C F

    1996-02-01

    Accuracy of a patient treatment portal marking device and computerized tomography (CT) simulation have been clinically tested. A CT-based simulator has been assembled based on a commercial CT scanner. This includes visualization software and a computer-controlled laser drawing device. This laser drawing device is used to transfer the setup, central axis, and/or radiation portals from the CT simulator to the patient for appropriate patient skin marking. A protocol for clinical testing is reported. Twenty-five prospectively, sequentially accessioned patients have been analyzed. The simulation process can be completed in an average time of 62 min. Under many cases, the treatment portals can be designed and the patient marked in one session. Mechanical accuracy of the system was found to be within +/- 1mm. The portal projection accuracy in clinical cases is observed to be better than +/- 1.2 mm. Operating costs are equivalent to the conventional simulation process it replaces. Computed tomography simulation is a clinical accurate substitute for conventional simulation when used with an appropriate patient marking system and digitally reconstructed radiographs. Personnel time spent in CT simulation is equivalent to time in conventional simulation.

  14. Bridging the Gap between Basic and Clinical Sciences: A Description of a Radiological Anatomy Course

    ERIC Educational Resources Information Center

    Torres, Anna; Staskiewicz, Grzegorz J.; Lisiecka, Justyna; Pietrzyk, Lukasz; Czekajlo, Michael; Arancibia, Carlos U.; Maciejewski, Ryszard; Torres, Kamil

    2016-01-01

    A wide variety of medical imaging techniques pervade modern medicine, and the changing portability and performance of tools like ultrasound imaging have brought these medical imaging techniques into the everyday practice of many specialties outside of radiology. However, proper interpretation of ultrasonographic and computed tomographic images…

  15. A new computerized cognitive and social cognition training specifically designed for patients with schizophrenia/schizoaffective disorder in early stages of illness: A pilot study.

    PubMed

    Fernandez-Gonzalo, Sol; Turon, Marc; Jodar, Merce; Pousa, Esther; Hernandez Rambla, Carla; García, Rebeca; Palao, Diego

    2015-08-30

    People with schizophrenia/schizoaffective disorders at early stages of the illness present cognitive and social cognition deficits that have a great impact in functional outcomes. Cognitive Remediation Therapy (CRT) has demonstrated consistent effect in cognitive performance, symptoms and psychosocial functioning. However, any CRT intervention or social cognition training have been specifically designed for patients in the early stages of psychosis. The aim of this pilot study is to assess the efficacy of a new computerized cognitive and social cognition program for patients with schizophrenia/schizoaffective disorder with recent diagnosis. A comprehensive assessment of clinical, social and non-social cognitive and functional measures was carried out in 53 randomized participants before and after the 4-months treatment. Significant results were observed in Spatial Span Forwards, Immediate Logical Memory and Pictures of Facial Affect (POFA) total score. None of these results were explained by medication, premorbid social functioning or psychopathological symptoms. No impact of the intervention was observed in other cognitive and social cognition outcome neither in clinical and functional outcomes. This new computerized intervention may result effective ameliorating visual attention, logical memory and emotional processing in patients in the early stages of schizophrenia/schizoaffective disorder. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Performance on a computerized shopping task significantly predicts real world functioning in persons diagnosed with bipolar disorder.

    PubMed

    Laloyaux, Julien; Pellegrini, Nadia; Mourad, Haitham; Bertrand, Hervé; Domken, Marc-André; Van der Linden, Martial; Larøi, Frank

    2013-12-15

    Persons diagnosed with bipolar disorder often suffer from cognitive impairments. However, little is known concerning how these cognitive deficits impact their real world functioning. We developed a computerized real-life activity task, where participants are required to shop for a list of grocery store items. Twenty one individuals diagnosed with bipolar disorder and 21 matched healthy controls were administered the computerized shopping task. Moreover, the patient group was assessed with a battery of cognitive tests and clinical scales. Performance on the shopping task significantly differentiated patients and healthy controls for two variables: Total time to complete the shopping task and Mean time spent to consult the shopping list. Moreover, in the patient group, performance on these variables from the shopping task correlated significantly with cognitive functioning (i.e. processing speed, verbal episodic memory, planning, cognitive flexibility, and inhibition) and with clinical variables including duration of illness and real world functioning. Finally, variables from the shopping task were found to significantly explain 41% of real world functioning of patients diagnosed with bipolar disorder. These findings suggest that the shopping task provides a good indication of real world functioning and cognitive functioning of persons diagnosed with bipolar disorder. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Developing a modular architecture for creation of rule-based clinical diagnostic criteria.

    PubMed

    Hong, Na; Pathak, Jyotishman; Chute, Christopher G; Jiang, Guoqian

    2016-01-01

    With recent advances in computerized patient records system, there is an urgent need for producing computable and standards-based clinical diagnostic criteria. Notably, constructing rule-based clinical diagnosis criteria has become one of the goals in the International Classification of Diseases (ICD)-11 revision. However, few studies have been done in building a unified architecture to support the need for diagnostic criteria computerization. In this study, we present a modular architecture for enabling the creation of rule-based clinical diagnostic criteria leveraging Semantic Web technologies. The architecture consists of two modules: an authoring module that utilizes a standards-based information model and a translation module that leverages Semantic Web Rule Language (SWRL). In a prototype implementation, we created a diagnostic criteria upper ontology (DCUO) that integrates ICD-11 content model with the Quality Data Model (QDM). Using the DCUO, we developed a transformation tool that converts QDM-based diagnostic criteria into Semantic Web Rule Language (SWRL) representation. We evaluated the domain coverage of the upper ontology model using randomly selected diagnostic criteria from broad domains (n = 20). We also tested the transformation algorithms using 6 QDM templates for ontology population and 15 QDM-based criteria data for rule generation. As the results, the first draft of DCUO contains 14 root classes, 21 subclasses, 6 object properties and 1 data property. Investigation Findings, and Signs and Symptoms are the two most commonly used element types. All 6 HQMF templates are successfully parsed and populated into their corresponding domain specific ontologies and 14 rules (93.3 %) passed the rule validation. Our efforts in developing and prototyping a modular architecture provide useful insight into how to build a scalable solution to support diagnostic criteria representation and computerization.

  18. Evaluation of computerized decision support for oral anticoagulation management based in primary care.

    PubMed

    Fitzmaurice, D A; Hobbs, F D; Murray, E T; Bradley, C P; Holder, R

    1996-09-01

    Increasing indications for oral anticoagulation has led to pressure on general practices to undertake therapeutic monitoring. Computerized decision support (DSS) has been shown to be effective in hospitals for improving clinical management. Its usefulness in primary care has previously not been investigated. To test the effectiveness of using DSS for oral anticoagulation monitoring in primary care by measuring the proportions of patients adequately controlled, defined as within the appropriate therapeutic range of International Normalised Ratio (INR). All patients receiving warfarin from two Birmingham inner city general practices were invited to attend a practice-based anticoagulation clinic. In practice A all patients were managed using DSS. In practice B patients were randomized to receive dosing advice either through DSS or through the local hospital laboratory. Clinical outcomes, adverse events and patient acceptability were recorded. Forty-nine patients were seen in total. There were significant improvements in INR control from 23% to 86% (P > 0.001) in the practice where all patients received dosing through DSS. In the practice where patients were randomized to either DSS or hospital dosing, logistic regression showed a significant trend for improvement in intervention patients which was not apparent in the hospital-dosed patients (P < 0.001). Mean recall times were significantly extended in patients who were dosed by the practice DSS through the full 12 months (24 days to 36 days) (P = 0.033). Adverse events were comparable between hospital and practice-dosed patients, although a number of esoteric events occurred. Patient satisfaction with the practice clinics was high. Computerized DSS enables the safe and effective transfer of anticoagulation management from hospital to primary care and may result in improved patient outcome in terms of the level of control, frequency of review and general acceptability.

  19. FFDM image quality assessment using computerized image texture analysis

    NASA Astrophysics Data System (ADS)

    Berger, Rachelle; Carton, Ann-Katherine; Maidment, Andrew D. A.; Kontos, Despina

    2010-04-01

    Quantitative measures of image quality (IQ) are routinely obtained during the evaluation of imaging systems. These measures, however, do not necessarily correlate with the IQ of the actual clinical images, which can also be affected by factors such as patient positioning. No quantitative method currently exists to evaluate clinical IQ. Therefore, we investigated the potential of using computerized image texture analysis to quantitatively assess IQ. Our hypothesis is that image texture features can be used to assess IQ as a measure of the image signal-to-noise ratio (SNR). To test feasibility, the "Rachel" anthropomorphic breast phantom (Model 169, Gammex RMI) was imaged with a Senographe 2000D FFDM system (GE Healthcare) using 220 unique exposure settings (target/filter, kVs, and mAs combinations). The mAs were varied from 10%-300% of that required for an average glandular dose (AGD) of 1.8 mGy. A 2.5cm2 retroareolar region of interest (ROI) was segmented from each image. The SNR was computed from the ROIs segmented from images linear with dose (i.e., raw images) after flat-field and off-set correction. Image texture features of skewness, coarseness, contrast, energy, homogeneity, and fractal dimension were computed from the Premium ViewTM postprocessed image ROIs. Multiple linear regression demonstrated a strong association between the computed image texture features and SNR (R2=0.92, p<=0.001). When including kV, target and filter as additional predictor variables, a stronger association with SNR was observed (R2=0.95, p<=0.001). The strong associations indicate that computerized image texture analysis can be used to measure image SNR and potentially aid in automating IQ assessment as a component of the clinical workflow. Further work is underway to validate our findings in larger clinical datasets.

  20. The digital pen and paper technology: implementation and use in an existing clinical information system.

    PubMed

    Despont-Gros, Christelle; Bœuf, Christophe; Geissbuhler, Antoine; Lovis, Christian

    2005-01-01

    Evaluation of the technical feasibility of tight integration of the digital pen and paper technology in an existing computerized patient record.Technology: The digital pen is a normal pen able to record all actions of the user and to analyze a micro pattern printed on the paper. The digital paper is a normal paper printed with an almost invisible micro pattern of small dots encoding information such as position and identifiers. We report our experience in the implementation and the use of this technology in an existing large clinical information system for acquiring clinical information. It is possible to print uniquely identified forms using the digital paper technology. These forms can be pre-filled with clinical readable information about the patient. When care providers complete these forms using the digital pen, it is possible to acquire the data in a structured computerized patient record. The technology is easy to integrate in a component-based architecture based on Web Services. The digital pen and paper is a cost-effective technology that can be integrated in an existing clinical information system and allows fast and easy bedside clinical information acquisition without the need for an expensive infrastructure based on traditional portable devices or wireless devices.

  1. Cone Beam Computed Tomographic imaging in orthodontics.

    PubMed

    Scarfe, W C; Azevedo, B; Toghyani, S; Farman, A G

    2017-03-01

    Over the last 15 years, cone beam computed tomographic (CBCT) imaging has emerged as an important supplemental radiographic technique for orthodontic diagnosis and treatment planning, especially in situations which require an understanding of the complex anatomic relationships and surrounding structures of the maxillofacial skeleton. CBCT imaging provides unique features and advantages to enhance orthodontic practice over conventional extraoral radiographic imaging. While it is the responsibility of each practitioner to make a decision, in tandem with the patient/family, consensus-derived, evidence-based clinical guidelines are available to assist the clinician in the decision-making process. Specific recommendations provide selection guidance based on variables such as phase of treatment, clinically-assessed treatment difficulty, the presence of dental and/or skeletal modifying conditions, and pathology. CBCT imaging in orthodontics should always be considered wisely as children have conservatively, on average, a three to five times greater radiation risk compared with adults for the same exposure. The purpose of this paper is to provide an understanding of the operation of CBCT equipment as it relates to image quality and dose, highlight the benefits of the technique in orthodontic practice, and provide guidance on appropriate clinical use with respect to radiation dose and relative risk, particularly for the paediatric patient. © 2017 Australian Dental Association.

  2. X-ray fluorescence tomographic system design and image reconstruction.

    PubMed

    Cong, Wenxiang; Shen, Haiou; Cao, Guohua; Liu, Hong; Wang, Ge

    2013-01-01

    In this paper, we presented a new design of x-ray fluorescence CT imaging system. For detecting fuorescence signals of gold nanoparticles in-vivo, multiple spectroscopic detectors are arranged and rotated orthogonal to an excited region of interest so that a localized scan can be acquired with a maximized efficiency. Excitation filtration was employed to minimize the effects of low-energy x-rays and background scattering for lowering radiation dose to the object. Numerical simulations showed that the radiation dose is less than 300 mGy/second for a complete 30 views tomographic scan; and the sensitivity of 3D fluorescence signal detection is up to 0.2% contrast concentrations of nanoparticles. The x-ray fluorescence computed tomography is an important molecular imaging tool. It can be used directly in samall animal research. It has great translational potential for future clinical applications.

  3. Computerizing medical records in Japan.

    PubMed

    Yasunaga, Hideo; Imamura, Tomoaki; Yamaki, Shintaro; Endo, Hiroyoshi

    2008-10-01

    The present study reports the current status of computerizing medical records in Japan. In 2001, the Ministry of Health, Labour and Welfare formulated the Grand Design for the Development of Information Systems in the Healthcare and Medical Fields. The Grand Design stated a numerical target for "spreading the use of electronic medical records (EMR) in at least 60% of Japan's hospitals with 400 or more beds by 2006." The objective of this study was to examine the extent to which EMR and order entry systems (OES) have been adopted as of February 2007 and to evaluate the Japanese government's policy regarding the computerization of medical records. We conducted a postal survey targeting medical institutions throughout Japan. In February 2007, we mailed self-administered questionnaires to all 1574 hospitals with 300 or more beds, and to a random selection of 1000 hospitals with less than 300 beds in addition to 4000 clinics. Responses were received from 812 (51.6%), 504 (50.5%), and 1769 (44.8%), respectively. We asked questions concerning: (i) the extent to which EMR and OES had been introduced; (ii) the reasons why certain institutions had not introduced EMR and (iii) the subjective evaluation of the efficacy and cost-effectiveness of EMR. The percentage of institutions that had introduced EMR as of February 2007 was 10.0% for hospitals and 10.1% for clinics. Even the percentage for hospitals with 400 or more beds was just 31.2%, illustrating that the government's target had not been reached. The most common reason given for not introducing EMR was: "The cost is high" which was observed in 82.0% of hospitals. It was considered that the introduction of EMR could improve 'inter-hospital networks', and 'time efficiency for physicians' by around 45% and 25% of hospitals, respectively. Healthcare information computerization in Japan is behind schedule because the introductory costs are high. For the computerization of healthcare information to be further promoted, prices of EMR systems should be lowered to a level which individual hospitals can afford. Furthermore, the communication between EMR systems should be further standardized to secure functional and semantic interoperability in Japan.

  4. Which test for CAD should be used in patients with left bundle branch block?

    PubMed

    Xu, Bo; Cremer, Paul; Jaber, Wael; Moir, Stuart; Harb, Serge C; Rodriguez, L Leonardo

    2018-03-01

    Exercise stress electrocardiography is unreliable as a test for obstructive coronary artery disease (CAD) if the patient has left bundle branch block. The authors provide an algorithm for using alternative tests: exercise stress echocardiography, dobutamine echocardiography, computed tomographic (CT) angiography, and nuclear myocardial perfusion imaging. Copyright © 2018 Cleveland Clinic.

  5. [Computed tomographic and clinical validation of the use of endosseous titanium nickelide dental implants].

    PubMed

    Temerkhanov, F T; Garafutdinov, D M; Arkharov, S L

    1997-01-01

    The authors analyze the efficacy of repair of atrophied [correction of arthrophic] alveolar processes of the jaws in the projections of the maxillary sinus and inferior alveolar canal with endosseous implants with porous cone-dilating mesostructure made of TN-1P alloy. Prospects for using the new implant design are outlined.

  6. Coverage and predictors of vaccination against 2012/13 seasonal influenza in Madrid, Spain: analysis of population-based computerized immunization registries and clinical records.

    PubMed

    Jiménez-García, Rodrigo; Esteban-Vasallo, María D; Rodríguez-Rieiro, Cristina; Hernandez-Barrera, Valentín; Domínguez-Berjón, M A Felicitas; Carrasco Garrido, Pilar; Lopez de Andres, Ana; Cameno Heras, Moises; Iniesta Fornies, Domingo; Astray-Mochales, Jenaro

    2014-01-01

    We aim to determine 2012-13 seasonal influenza vaccination coverage. Data were analyzed by age group and by coexistence of concomitant chronic conditions. Factors associated with vaccine uptake were identified. We also analyze a possible trend in vaccine uptake in post pandemic seasons. We used computerized immunization registries and clinical records of the entire population of the Autonomous Community of Madrid, Spain (6,284,128 persons) as data source. A total of 871,631 individuals were vaccinated (13.87%). Coverage for people aged ≥ 65 years was 56.57%. Global coverage in people with a chronic condition was 15.7% in children and 18.69% in adults aged 15-59 years. The variables significantly associated with a higher likelihood of being vaccinated in the 2012-13 campaign for the age groups studied were higher age, being Spanish-born, higher number of doses of seasonal vaccine received in previous campaigns, uptake of pandemic vaccination, and having a chronic condition. We conclude that vaccination coverage in persons aged<60 years with chronic conditions is less than acceptable. The very low coverage among children with chronic conditions calls for urgent interventions. Among those aged ≥60 years, uptake is higher but still far from optimal and seems to be descending in post-pandemic campaigns. For those aged ≥65 years the mean percentage of decrease from the 2009/10 to the actual campaign has been 12%. Computerized clinical and immunization registers are useful tools for providing rapid and detailed information about influenza vaccination coverage in the population.

  7. Validation of an electronic surveillance system for acute lung injury

    PubMed Central

    Herasevich, Vitaly; Yilmaz, Murat; Khan, Hasrat; Hubmayr, Rolf D.; Gajic, Ognjen

    2009-01-01

    Objective Early detection of acute lung injury (ALI) is essential for timely implementation of evidence-based therapies and enrollment into clinical trials. We aimed to determine the accuracy of computerized syndrome surveillance for detection of ALI in hospitalized patients and compare it with routine clinical assessment. Design Using a near-real time copy of the electronic medical records we developed and validated a custom ALI electronic alert (ALI “sniffer”) based on the European-American Consensus Conference Definition and compared its performance against provider derived documentation. Patients and setting Consecutive 3795 critically ill patients admitted to 9 multidisciplinary intensive care units (ICUs) of a tertiary care teaching institution. Measurements and main results ALI developed in 325 patients and was recognized by bedside clinicians in only 86 (26.5%). Under-recognition of ALI was associated with not implementing protective mechanical ventilation (median tidal volumes of 9.2 vs 8.0 mL/kg predicted body weight, p<0.001). ALI “sniffer” demonstrated excellent sensitivity, 96% (95% CI 94 to 98) and moderate specificity, 89% (95% CI 88 to 90) with a positive predictive value ranging from 24% (95% CI 13 to 40) in the heart-lung transplant ICU to 64% (95% CI 55 to 71) in the medical ICU. Conclusions Computerized surveillance system accurately identifies critically ill patients who develop ALI syndrome. Since the lack of ALI recognition is a barrier to the timely implementation of best practices and enrollment into research studies, computerized syndrome surveillance could be a useful tool to enhance patient safety and clinical research. PMID:19280175

  8. Computerized Decision Support System Improves Fluid Resuscitation Outcomes Following Severe Burns: An Original Study

    DTIC Science & Technology

    2011-01-01

    clinical decision- making paradigms, coupled with regula- tory and technical limitations, is just one of the hurdles that has kept advanced information...responses to assist care personnel during the resuscitation phase. CDSSs have been successfully used in the clinical setting for several years (23–24...because of clinical complications, death, or other factors were excluded. The control cohort included only patients who sur- vived for the initial 24

  9. Objective Assessment of the Interfrontal Angle for Severity Grading and Operative Decision-Making in Metopic Synostosis.

    PubMed

    Anolik, Rachel A; Allori, Alexander C; Pourtaheri, Navid; Rogers, Gary F; Marcus, Jeffrey R

    2016-05-01

    The purpose of this study was to evaluate the utility of a previously validated interfrontal angle for classification of severity of metopic synostosis and as an aid to operative decision-making. An expert panel was asked to study 30 cases ranging from minor to severe metopic synostosis. Based on computed tomographic images of the skull and clinical photographs, they classified the severity of trigonocephaly (1 = normal, 2 = mild, 3 = moderate, and 4 = severe) and management (0 = nonoperative and 1 = operative). The severity scores and management reported by experts were then pooled and matched with the interfrontal angle computed from each respective computed tomographic scan. A threshold was identified at which most experts agree on operative management. Expert severity scores were higher for more acute interfrontal angles. There was a high concordance at the extremes of classifications, severe (4) and normal (1) (p < 0.0001); however, between interfrontal angles of 114.3 and 136.1 degrees, there exists a "gray zone," with severe discordance in expert rankings. An operative threshold of 118.2 degrees was identified, with the interfrontal angle able to predict the expert panel's decision to proceed with surgery 87.6 percent of the time. The interfrontal angle has been previously validated as a simple, accurate, and reproducible means for diagnosing trigonocephaly, but must be obtained from computed tomographic data. In this article, the authors demonstrate that the interfrontal angle can be used to further characterize the severity of trigonocephaly. It also correlated with expert decision-making for operative versus nonoperative management. This tool may be used as an adjunct to clinical decision-making when the decision to proceed with surgery may not be straightforward. Diagnostic, V.

  10. Association of Brachial-Ankle Pulse Wave Velocity with Asymptomatic Intracranial Arterial Stenosis in Hypertension Patients.

    PubMed

    Wang, Yan; Zhang, Jin; Qain, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang

    2016-08-01

    Intracranial arterial stenosis is a common cause of ischemic stroke in Asians. We therefore sought to explore the relationship of brachial-ankle pulse wave velocity and intracranial arterial stenosis in 834 stroke-free hypertensive patients. Intracranial arterial stenosis was evaluated through computerized tomographic angiography. Brachial-ankle pulse wave velocity was measured by an automated cuff device. The top decile of brachial-ankle pulse wave velocity was significantly associated with intracranial arterial stenosis (P = .027, odds ratio = 1.82; 95% confidence interval: 1.07-3.10). The patients with the top decile of brachial-ankle pulse wave velocity showed 56% higher risk for the presence of intracranial arterial stenosis to the whole population, which was more significant in patients younger than 65 years old. We also found that brachial-ankle pulse wave velocity related to both intracranial arterial stenosis and homocysteine. Our study showed the association of brachial-ankle pulse wave velocity with asymptomatic intracranial arterial stenosis in hypertension patients, especially in relative younger subjects. Brachial-ankle pulse wave velocity might be a relatively simple and repeatable measurement to detect hypertension patients in high risk of intracranial arterial stenosis. Copyright © 2016. Published by Elsevier Inc.

  11. Role of CT scanning in formation evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergosh, J.L.; Dibona, B.G.

    1988-01-01

    The use of the computerized tomographic (CT) scanner in formation evaluation of difficult to analyze core samples has moved from the research and development phase to daily, routine use in the core-analysis laboratory. The role of the CT scanner has become increasingly important as geologists try to obtain more representative core material for accurate formation evaluation. The most common problem facing the core analyst when preparing to measure petrophysical properties is the selection of representative and unaltered core samples for routine and special core testing. Recent data have shown that heterogeneous reservoir rock can be very difficult, if not impossible,more » to assess correctly when using standard core examination procedures, because many features, such as fractures, are not visible on the core surface. Another problem is the invasion of drilling mud into the core sample. Flushing formation oil and water from the core can greatly alter the saturation and distribution of fluids and lead to serious formation evaluation problems. Because the quality and usefulness of the core date are directly tied to proper sample selection, it has become imperative that the CT scanner be used whenever possible.« less

  12. Chondro-manubrial deformity and bifid rib, rare variations seen in pectus carinatum: a radiological finding.

    PubMed

    Allwyn Joshua, S; Shetty, Lathika; Pare, V S; Sebastian, Roopa

    2013-07-01

    Pectus carinatum or protrusion deformity of chest wall is less frequently occurring anterior chest wall deformity when compared to pectus excavatum. It may be classified as type 1 or chondro-gladiolar and type 2 or chondro-manubrial deformity. Other variations seen are symmetrical and asymmetrical pectus carinatum. Here we present two unique case reports, one with chondro-manubrial deformity (Currarino-Silverman syndrome) and other with asymmetrical pectus carinatum having bifid rib which are some of the rare variations seen in pectus carinatum found during Computerized tomographic examination. Currarino-Silverman syndrome is a type 2 pectus carinatum, a rare deformity with chondro-manubrial involvement and usually associated congenital heart diseases. Early fusion of sternal plates is one of the known theories in producing this deformity. On the other hand, asymmetrical pectus deformity are usually seen due to imbalance or abnormality in growth plates of costal cartilages leading to forked rib or bifid rib, which are accidently seen on radiological examination. To conclude, our reports would help in differential diagnosis from frequently occurring conditions affecting chest like chondro-gladiolar deformity, pectus excavatum, chest wall tumours, rib fractures and intra thoracic ribs.

  13. Preoperative predictive model of cervical lymph node metastasis combining fluorine-18 fluorodeoxyglucose positron-emission tomography/computerized tomography findings and clinical factors in patients with oral or oropharyngeal squamous cell carcinoma.

    PubMed

    Mochizuki, Yumi; Omura, Ken; Nakamura, Shin; Harada, Hiroyuki; Shibuya, Hitoshi; Kurabayashi, Toru

    2012-02-01

    This study aimed to construct a preoperative predictive model of cervical lymph node metastasis using fluorine-18 fluorodeoxyglucose positron-emission tomography/computerized tomography ((18)F-FDG PET/CT) findings in patients with oral or oropharyngeal squamous cell carcinoma (SCC). Forty-nine such patients undergoing preoperative (18)F-FDG PET/CT and neck dissection or lymph node biopsy were enrolled. Retrospective comparisons with spatial correlation between PET/CT and the anatomical sites based on histopathological examinations of surgical specimens were performed. We calculated a logistic regression model, including the SUVmax-related variable. When using the optimal cutoff point criterion of probabilities calculated from the model that included either clinical factors and delayed-phase SUVmax ≥0.087 or clinical factors and maximum standardized uptake (SUV) increasing rate (SUV-IR) ≥ 0.100, it significantly increased the sensitivity, specificity, and accuracy (87.5%, 65.7%, and 75.2%, respectively). The use of predictive models that include clinical factors and delayed-phase SUVmax and SUV-IR improve preoperative nodal diagnosis. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Tomographic diagnostics of nonthermal plasmas

    NASA Astrophysics Data System (ADS)

    Denisova, Natalia

    2009-10-01

    In the previous work [1], we discussed a ``technology'' of tomographic method and relations between the tomographic diagnostics in thermal (equilibrium) and nonthermal (nonequilibrium) plasma sources. The conclusion has been made that tomographic reconstruction in thermal plasma sources is the standard procedure at present, which can provide much useful information on the plasma structure and its evolution in time, while the tomographic reconstruction of nonthermal plasma has a great potential at making a contribution to understanding the fundamental problem of substance behavior in strongly nonequilibrium conditions. Using medical terminology, one could say, that tomographic diagnostics of the equilibrium plasma sources studies their ``anatomic'' structure, while reconstruction of the nonequilibrium plasma is similar to the ``physiological'' examination: it is directed to study the physical mechanisms and processes. The present work is focused on nonthermal plasma research. The tomographic diagnostics is directed to study spatial structures formed in the gas discharge plasmas under the influence of electrical and gravitational fields. The ways of plasma ``self-organization'' in changing and extreme conditions are analyzed. The analysis has been made using some examples from our practical tomographic diagnostics of nonthermal plasma sources, such as low-pressure capacitive and inductive discharges. [0pt] [1] Denisova N. Plasma diagnostics using computed tomography method // IEEE Trans. Plasma Sci. 2009 37 4 502.

  15. Attitudes of First-year Medical Students Toward the Confidentiality of Computerized Patient Records

    PubMed Central

    Davis, Luke; Domm, Jennifer A.; Konikoff, Michael R.; Miller, Randolph A.

    1999-01-01

    Objectives: To investigate the attitudes of students entering medical school toward the confidentiality of computerized medical records. Design: First-year medical students at the Vanderbilt University School of Medicine responded to a series of questions about a hypothetic breach of patient's privacy through a computerized patient record system. Measurements: The individual authors independently grouped the blinded responses according to whether they were consistent with then-current institutional policy. These preliminary groupings were discussed, and final categorizations were made by consensus. Results: While most students had a sense of what was right and wrong in absolute terms, half the class suggested at least one course of action that was deemed to be inconsistent with institutional policies. Conclusions: The authors believe that medical schools should directly address ethical and legal issues related to the use of computers in clinical practice as an integral part of medical school curricula. Several teaching approaches can facilitate a greater awareness of the issues surrounding technology and medicine. PMID:9925228

  16. Transfusion audit of fresh-frozen plasma in southern Taiwan.

    PubMed

    Yeh, C-J; Wu, C-F; Hsu, W-T; Hsieh, L-L; Lin, S-F; Liu, T-C

    2006-10-01

    The demand for transfusions has increased rapidly in southern Taiwan. Between 1993 and 2003, requests for fresh-frozen plasma (FFP) in particular rose dramatically at Kaohsiung Medical University Hospital (KMUH). Transfusion orders were not tightly regulated, and inappropriate use of blood products was common. We carried out a prospective analysis of transfusion requests from October 2003 to January 2004 at KMUH, and then repeated the audit for another 3-month period after the clinical faculty had undergone five sessions of education on transfusion guidelines. Later, our consultant haematologist applied computerized guidelines to periodic audits. A 5.2% decrease in inappropriate FFP usage followed the educational programme and a further 30% reduction took place after the application of computerized transfusion guidelines. With the guidelines and periodic audits, FFP transfusions decreased by 74.6% and inappropriate requests from 65.2% to 30%. Hospital policy, computerized transfusion guidelines and periodic audits greatly reduced inappropriate FFP transfusions. An educational campaign had a more limited effect.

  17. Colorectal cancer screening with virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Ge, Yaorong; Vining, David J.; Ahn, David K.; Stelts, David R.

    1999-05-01

    Early detection and removal of colorectal polyps have been proven to reduce mortality from colorectal carcinoma (CRC), the second leading cause of cancer deaths in the United States. Unfortunately, traditional techniques for CRC examination (i.e., barium enema, sigmoidoscopy, and colonoscopy) are unsuitable for mass screening because of either low accuracy or poor public acceptance, costs, and risks. Virtual colonoscopy (VC) is a minimally invasive alternative that is based on tomographic scanning of the colon. After a patient's bowel is optimally cleansed and distended with gas, a fast tomographic scan, typically helical computed tomography (CT), of the abdomen is performed during a single breath-hold acquisition. Two-dimensional (2D) slices and three-dimensional (3D) rendered views of the colon lumen generated from the tomographic data are then examined for colorectal polyps. Recent clinical studies conducted at several institutions including ours have shown great potential for this technology to be an effective CRC screening tool. In this paper, we describe new methods to improve bowel preparation, colon lumen visualization, colon segmentation, and polyp detection. Our initial results show that VC with the new bowel preparation and imaging protocol is capable of achieving accuracy comparable to conventional colonoscopy and our new algorithms for image analysis contribute to increased accuracy and efficiency in VC examinations.

  18. Computed Tomographic Analysis of Ventral Atlantoaxial Optimal Safe Implantation Corridors in 27 Dogs.

    PubMed

    Leblond, Guillaume; Gaitero, Luis; Moens, Noel M M; Zur Linden, Alex; James, Fiona M K; Monteith, Gabrielle J; Runciman, John

    2017-11-01

    Objectives  Ventral atlantoaxial stabilization techniques are challenging surgical procedures in dogs. Available surgical guidelines are based upon subjective anatomical landmarks, and limited radiographic and computed tomographic data. The aims of this study were (1) to provide detailed anatomical descriptions of atlantoaxial optimal safe implantation corridors to generate objective recommendations for optimal implant placements and (2) to compare anatomical data obtained in non-affected Toy breed dogs, affected Toy breed dogs suffering from atlantoaxial instability and non-affected Beagle dogs. Methods  Anatomical data were collected from a prospectively recruited population of 27 dogs using a previously validated method of optimal safe implantation corridor analysis using computed tomographic images. Results  Optimal implant positions and three-dimensional numerical data were generated successfully in all cases. Anatomical landmarks could be used to generate objective definitions of optimal insertion points which were applicable across all three groups. Overall the geometrical distribution of all implant sites was similar in all three groups with a few exceptions. Clinical Significance  This study provides extensive anatomical data available to facilitate surgical planning of implant placement for atlantoaxial stabilization. Our data suggest that non-affected Toy breed dogs and non-affected Beagle dogs constitute reasonable research models to study atlantoaxial stabilization constructs. Schattauer GmbH Stuttgart.

  19. Non-contact continuous-wave diffuse optical tomographic system to capture vascular dynamics in the foot

    NASA Astrophysics Data System (ADS)

    Hoi, Jennifer W.; Kim, Hyun K.; Khalil, Michael A.; Fong, Christopher J.; Marone, Alessandro; Shrikhande, Gautam; Hielscher, Andreas H.

    2015-03-01

    Dynamic optical tomographic imaging has shown promise in diagnosing and monitoring peripheral arterial disease (PAD), which affects 8 to 12 million in the United States. PAD is the narrowing of the arteries that supply blood to the lower extremities. Prolonged reduced blood flow to the foot leads to ulcers and gangrene, which makes placement of optical fibers for contact-based optical tomography systems difficult and cumbersome. Since many diabetic PAD patients have foot wounds, a non-contact interface is highly desirable. We present a novel non-contact dynamic continuous-wave optical tomographic imaging system that images the vasculature in the foot for evaluating PAD. The system images at up to 1Hz by delivering 2 wavelengths of light to the top of the foot at up to 20 source positions through collimated source fibers. Transmitted light is collected with an electron multiplying charge couple device (EMCCD) camera. We demonstrate that the system can resolve absorbers at various locations in a phantom study and show the system's first clinical 3D images of total hemoglobin changes in the foot during venous occlusion at the thigh. Our initial results indicate that this system is effective in capturing the vascular dynamics within the foot and can be used to diagnose and monitor treatment of PAD in diabetic patients.

  20. Computer-aided interpretation approach for optical tomographic images

    NASA Astrophysics Data System (ADS)

    Klose, Christian D.; Klose, Alexander D.; Netz, Uwe J.; Scheel, Alexander K.; Beuthan, Jürgen; Hielscher, Andreas H.

    2010-11-01

    A computer-aided interpretation approach is proposed to detect rheumatic arthritis (RA) in human finger joints using optical tomographic images. The image interpretation method employs a classification algorithm that makes use of a so-called self-organizing mapping scheme to classify fingers as either affected or unaffected by RA. Unlike in previous studies, this allows for combining multiple image features, such as minimum and maximum values of the absorption coefficient for identifying affected and not affected joints. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index, and mutual information. Different methods (i.e., clinical diagnostics, ultrasound imaging, magnet resonance imaging, and inspection of optical tomographic images), were used to produce ground truth benchmarks to determine the performance of image interpretations. Using data from 100 finger joints, findings suggest that some parameter combinations lead to higher sensitivities, while others to higher specificities when compared to single parameter classifications employed in previous studies. Maximum performances are reached when combining the minimum/maximum ratio of the absorption coefficient and image variance. In this case, sensitivities and specificities over 0.9 can be achieved. These values are much higher than values obtained when only single parameter classifications were used, where sensitivities and specificities remained well below 0.8.

  1. Integrating Prevention into Obstetrics/Gynecology.

    ERIC Educational Resources Information Center

    Carey, J. Christopher

    2000-01-01

    Discusses formats to teach preventive medicine in obstetrics and gynecology (including learning objectives, lectures/seminars, and rounds/office practice) and evaluation methods (oral examinations, computerized question banks, objective structured clinical examinations). Offers examples from specific programs at American medical schools, including…

  2. The Use of Chest Computed Tomographic Angiography in Blunt Trauma Pediatric Population.

    PubMed

    Hasadia, Rabea; DuBose, Joseph; Peleg, Kobi; Stephenson, Jacob; Givon, Adi; Kessel, Boris

    2018-02-05

    Blunt chest trauma in children is common. Although rare, associated major thoracic vascular injuries (TVIs) are lethal potential sequelae of these mechanisms. The preferred study for definitive diagnosis of TVI in stable patients is computed tomographic angiography imaging of the chest. This imaging modality is, however, associated with high doses of ionizing radiation that represent significant carcinogenic risk for pediatric patients. The aim of the present investigation was to define the incidence of TVI among blunt pediatric trauma patients in an effort to better elucidate the usefulness of computed tomographic angiography use in this population. A retrospective cohort study was conducted including all blunt pediatric (age < 14 y) trauma victims registered in Israeli National Trauma Registry maintained by Gertner Institute for Epidemiology and Health Policy Research between the years 1997 and 2015. Data collected included age, sex, mechanism of injury, Glasgow Coma Scale, Injury Severity Score, and incidence of chest named vessel injuries. Statistical analysis was performed using SAS statistical software version 9.2 (SAS Institute Inc, Cary, NC). Among 433,325 blunt trauma victims, 119,821patients were younger than 14 years. Twelve (0.0001%, 12/119821) of these children were diagnosed with TVI. The most common mechanism in this group was pedestrian hit by a car. Mortality was 41.7% (5/12). Thoracic vascular injury is exceptionally rare among pediatric blunt trauma victims but does contribute to the high morbidity and mortality seen with blunt chest trauma. Computed tomographic angiography, with its associated radiation exposure risk, should not be used as a standard tool after trauma in injured children. Clinical protocols are needed in this population to minimize radiation risk while allowing prompt identification of life-threatening injuries.

  3. The impact of automation on organizational changes in a community hospital clinical microbiology laboratory.

    PubMed

    Camporese, Alessandro

    2004-06-01

    The diagnosis of infectious diseases and the role of the microbiology laboratory are currently undergoing a process of change. The need for overall efficiency in providing results is now given the same importance as accuracy. This means that laboratories must be able to produce quality results in less time with the capacity to interpret the results clinically. To improve the clinical impact of microbiology results, the new challenge facing the microbiologist has become one of process management instead of pure analysis. A proper project management process designed to improve workflow, reduce analytical time, and provide the same high quality results without losing valuable time treating the patient, has become essential. Our objective was to study the impact of introducing automation and computerization into the microbiology laboratory, and the reorganization of the laboratory workflow, i.e. scheduling personnel to work shifts covering both the entire day and the entire week. In our laboratory, the introduction of automation and computerization, as well as the reorganization of personnel, thus the workflow itself, has resulted in an improvement in response time and greater efficiency in diagnostic procedures.

  4. A Computerized Data-Capture System for Animal Biosafety Level 4 Laboratories

    PubMed Central

    Bente, Dennis A; Friesen, Jeremy; White, Kyle; Koll, Jordan; Kobinger, Gary P

    2011-01-01

    The restrictive nature of an Animal Biosafety Level 4 (ABSL4) laboratory complicates even simple clinical evaluation including data capture. Typically, clinical data are recorded on paper during procedures, faxed out of the ABSL4, and subsequently manually entered into a computer. This system has many disadvantages including transcriptional errors. Here, we describe the development of a highly customizable, tablet-PC-based computerized data-capture system, allowing reliable collection of observational and clinical data from experimental animals in a restrictive biocontainment setting. A multidisciplinary team with skills in containment laboratory animal science, database design, and software engineering collaborated on the development of this system. The goals were to design an easy-to-use and flexible user interface on a touch-screen tablet PC with user-supportable processes for recovery, full auditing capabilities, and cost effectiveness. The system simplifies data capture, reduces the necessary time in an ABSL4 environment, offers timely reporting and review of data, facilitates statistical analysis, reduces potential of erroneous data entry, improves quality assurance of animal care, and advances the use and refinement of humane endpoints. PMID:22330712

  5. Computerized method for detection of vertebral fractures on lateral chest radiographs based on morphometric data

    NASA Astrophysics Data System (ADS)

    Kasai, Satoshi; Li, Feng; Shiraishi, Junji; Li, Qiang; Straus, Christopher; Vokes, Tamara; MacMahon, Heber; Doi, Kunio

    2007-03-01

    Vertebral fractures are the most common osteoporosis-related fractures. It is important to detect vertebral fractures, because they are associated with increased risk of subsequent fractures, and because pharmacologic therapy can reduce the risk of subsequent fractures. Although vertebral fractures are often not clinically recognized, they can be visualized on lateral chest radiographs taken for other purposes. However, only 15-60% of vertebral fractures found on lateral chest radiographs are mentioned in radiology reports. The purpose of this study was to develop a computerized method for detection of vertebral fractures on lateral chest radiographs in order to assist radiologists' image interpretation. Our computerized method is based on the automated identification of upper and lower vertebral edges. In order to develop the scheme, radiologists provided morphometric data for each identifiable vertebra, which consisted of six points for each vertebra, for 25 normals and 20 cases with severe fractures. Anatomical information was obtained from morphometric data of normal cases in terms of vertebral heights, heights of vertebral disk spaces, and vertebral centerline. Computerized detection of vertebral fractures was based on the reduction in the heights of fractured vertebrae compared to adjacent vertebrae and normal reference data. Vertebral heights from morphometric data on normal cases were used as reference. On 138 chest radiographs (20 with fractures) the sensitivity of our method for detection of fracture cases was 95% (19/20) with 0.93 (110/118) false-positives per image. In conclusion, the computerized method would be useful for detection of potentially overlooked vertebral fractures on lateral chest radiographs.

  6. Feasibility of a computerized intervention for offenders with substance use disorders: a research note.

    PubMed

    Chaple, Michael; Sacks, Stanley; McKendrick, Karen; Marsch, Lisa A; Belenko, Steven; Leukefeld, Carl; Prendergast, Michael; French, Michael

    2014-01-01

    Despite evidence that treatment is effective in reducing recidivism among inmates with substance use problems, scarce resources mean that few of those in need of treatment actually receive it. Computerized substance abuse interventions could be used to expand access to treatment in prisons without placing an undue burden on resources. The major aim of the study was to compare treatment conditions in terms of their service utilization, skills acquisition, and treatment satisfaction. The study recruited men and women with substance use disorders from 10 prisons in 4 states. In an open label clinical trial, 494 subjects were randomly assigned either to the Experimental condition, a computerized drug treatment intervention, the Therapeutic Education System (TES; n  = 249), or to the Control condition, Standard Care ( n  = 245). Chi-square tests compared groups on categorical variables and independent samples t tests were used for interval level continuous variables. Initial evidence demonstrated: (1) comparable group rates of session attendance and high rates of TES module completion for experimental subjects; (2) comparable group gains in the development of coping skills; and (3) a more favorable view of TES than of Standard Care . Collectively, these results show that a computerized intervention, such as TES, can be implemented successfully in prison. Given the barriers to the delivery of substance abuse treatment typically encountered in correctional settings, computerized interventions have the potential to fill a significant treatment gap and are particularly well suited to inmates with mild to moderate substance use disorders who often are not treated.

  7. Exploiting Semantic Web Technologies to Develop OWL-Based Clinical Practice Guideline Execution Engines.

    PubMed

    Jafarpour, Borna; Abidi, Samina Raza; Abidi, Syed Sibte Raza

    2016-01-01

    Computerizing paper-based CPG and then executing them can provide evidence-informed decision support to physicians at the point of care. Semantic web technologies especially web ontology language (OWL) ontologies have been profusely used to represent computerized CPG. Using semantic web reasoning capabilities to execute OWL-based computerized CPG unties them from a specific custom-built CPG execution engine and increases their shareability as any OWL reasoner and triple store can be utilized for CPG execution. However, existing semantic web reasoning-based CPG execution engines suffer from lack of ability to execute CPG with high levels of expressivity, high cognitive load of computerization of paper-based CPG and updating their computerized versions. In order to address these limitations, we have developed three CPG execution engines based on OWL 1 DL, OWL 2 DL and OWL 2 DL + semantic web rule language (SWRL). OWL 1 DL serves as the base execution engine capable of executing a wide range of CPG constructs, however for executing highly complex CPG the OWL 2 DL and OWL 2 DL + SWRL offer additional executional capabilities. We evaluated the technical performance and medical correctness of our execution engines using a range of CPG. Technical evaluations show the efficiency of our CPG execution engines in terms of CPU time and validity of the generated recommendation in comparison to existing CPG execution engines. Medical evaluations by domain experts show the validity of the CPG-mediated therapy plans in terms of relevance, safety, and ordering for a wide range of patient scenarios.

  8. Computerized detection of leukocytes in microscopic leukorrhea images.

    PubMed

    Zhang, Jing; Zhong, Ya; Wang, Xiangzhou; Ni, Guangming; Du, Xiaohui; Liu, Juanxiu; Liu, Lin; Liu, Yong

    2017-09-01

    Detection of leukocytes is critical for the routine leukorrhea exam, which is widely used in gynecological examinations. An elevated vaginal leukocyte count in women with bacterial vaginosis is a strong predictor of vaginal or cervical infections. In the routine leukorrhea exam, the counting of leukocytes is primarily performed by manual techniques. However, the viewing and counting of leukocytes from multiple high-power viewing fields on a glass slide under a microscope leads to subjectivity, low efficiency, and low accuracy. To date, many biological cells in stool, blood, and breast cancer have been studied to realize computerized detection; however, the detection of leukocytes in microscopic leukorrhea images has not been studied. Thus, there is an increasing need for computerized detection of leukocytes. There are two key processes in the computerized detection of leukocytes in digital image processing. One is segmentation; the other is intelligent classification. In this paper, we propose a combined ensemble to detect leukocytes in the microscopic leukorrhea image. After image segmentation and selecting likely leukocyte subimages, we obtain the leukocyte candidates. Then, for intelligent classification, we adopt two methods: feature extraction and classification by a support vector machine (SVM); applying a modified convolutional neural network (CNN) to the larger subimages. If different methods classify a candidate in the same category, the process is finished. If not, the outputs of the methods are provided to a classifier to further classify the candidate. After acquiring leukocyte candidates, we attempted three methods to perform classification. The first approach using features and SVM achieved 88% sensitivity, 97% specificity, and 92.5% accuracy. The second method using CNN achieved 95% sensitivity, 84% specificity, and 89.5% accuracy. Then, in the combination approach, we achieved 92% sensitivity, 95% specificity, and 93.5% accuracy. Finally, the images with marked and counted leukocytes were obtained. A novel computerized detection system was developed for automated detection of leukocytes in microscopic images. Different methods resulted in comparable overall qualities by enabling computerized detection of leukocytes. The proposed approach further improved the performance. This preliminary study proves the feasibility of computerized detection of leukocytes in clinical use. © 2017 American Association of Physicists in Medicine.

  9. Summary of Panel Discussion.

    ERIC Educational Resources Information Center

    Druyan, Mary Ellen

    1990-01-01

    Viewpoints of speakers and participants at a symposium on nutrition education in dental curricula are reported, and recommendations for action are outlined, including recruitment of nutritionists for dental faculties, screening and counseling exercises in clinical training, instruction in interpretation of computerized dietary analysis, and…

  10. Three-dimensional radiotherapy of head and neck and esophageal carcinomas: a monoisocentric treatment technique to achieve improved dose distributions.

    PubMed

    Ahmad, M; Nath, R

    2001-02-20

    The specific aim of three-dimensional conformal radiotherapy is to deliver adequate therapeutic radiation dose to the target volume while concomitantly keeping the dose to surrounding and intervening normal tissues to a minimum. The objective of this study is to examine dose distributions produced by various radiotherapy techniques used in managing head and neck tumors when the upper part of the esophagus is also involved. Treatment planning was performed with a three-dimensional (3-D) treatment planning system. Computerized tomographic (CT) scans used by this system to generate isodose distributions and dose-volume histograms were obtained directly from the CT scanner, which is connected via ethernet cabling to the 3-D planning system. These are useful clinical tools for evaluating the dose distribution to the treatment volume, clinical target volume, gross tumor volume, and certain critical organs. Using 6 and 18 MV photon beams, different configurations of standard treatment techniques for head and neck and esophageal carcinoma were studied and the resulting dose distributions were analyzed. Film validation dosimetry in solid-water phantom was performed to assess the magnitude of dose inhomogeneity at the field junction. Real-time dose measurements on patients using diode dosimetry were made and compared with computed dose values. With regard to minimizing radiation dose to surrounding structures (i.e., lung, spinal cord, etc.), the monoisocentric technique gave the best isodose distributions in terms of dose uniformity. The mini-mantle anterior-posterior/posterior-anterior (AP/PA) technique produced grossly non-uniform dose distribution with excessive hot spots. The dose measured on the patient during the treatment agrees to within +/- 5 % with the computed dose. The protocols presented in this work for simulation, immobilization and treatment planning of patients with head and neck and esophageal tumors provide the optimum dose distributions in the target volume with reduced irradiation of surrounding non-target tissues, and can be routinely implemented in a radiation oncology department. The presence of a real-time dose-measuring system plays an important role in verifying the actual delivery of radiation dose.

  11. Low dose tomographic fluoroscopy: 4D intervention guidance with running prior

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, Barbara; Kuntz, Jan; Brehm, Marcus

    Purpose: Today's standard imaging technique in interventional radiology is the single- or biplane x-ray fluoroscopy which delivers 2D projection images as a function of time (2D+T). This state-of-the-art technology, however, suffers from its projective nature and is limited by the superposition of the patient's anatomy. Temporally resolved tomographic volumes (3D+T) would significantly improve the visualization of complex structures. A continuous tomographic data acquisition, if carried out with today's technology, would yield an excessive patient dose. Recently the authors proposed a method that enables tomographic fluoroscopy at the same dose level as projective fluoroscopy which means that if scanning time ofmore » an intervention guided by projective fluoroscopy is the same as that of an intervention guided by tomographic fluoroscopy, almost the same dose is administered to the patient. The purpose of this work is to extend authors' previous work and allow for patient motion during the intervention.Methods: The authors propose the running prior technique for adaptation of a prior image. This adaptation is realized by a combination of registration and projection replacement. In a first step the prior is deformed to the current position via affine and deformable registration. Then the information from outdated projections is replaced by newly acquired projections using forward and backprojection steps. The thus adapted volume is the running prior. The proposed method is validated by simulated as well as measured data. To investigate motion during intervention a moving head phantom was simulated. Real in vivo data of a pig are acquired by a prototype CT system consisting of a flat detector and a continuously rotating clinical gantry.Results: With the running prior technique it is possible to correct for motion without additional dose. For an application in intervention guidance both steps of the running prior technique, registration and replacement, are necessary. Reconstructed volumes based on the running prior show high image quality without introducing new artifacts and the interventional materials are displayed at the correct position.Conclusions: The running prior improves the robustness of low dose 3D+T intervention guidance toward intended or unintended patient motion.« less

  12. [Speech syndrome and its course in patients who have sustained an ischemic stroke (clinico-tomographic study)].

    PubMed

    Stoliarova, L G; Varakin, Iu Ia; Vavilov, S B

    1981-01-01

    Clinical and tomographic examinations of 40 patients with aphasia developed after an ischemic stroke were carried out. In more than half of them no correlation between the aphasia gravity and character on the one hand, and the size and localization of the ischemic focus (or foci) in the brain on the other was noted. With similar character and gravity of the speech disorder the size and localization of the ischemic foci may be different, ad vice versa. It has been shown that the interrelations between the focal pathology of the brain and the character and gravity of speech disorders are very complicated. One should take into consideration the possibility of individual organization of the speech functions, the degree of the speech activity automatism before the disease, and the state of the cerebrovascular system as a whole.

  13. Conservative orthodontic treatment of mandibular bilateral condyle fracture.

    PubMed

    Gašpar, Goran; Brakus, Ivan; Kovačić, Ivan

    2014-09-01

    Maxillofacial trauma is rare in children younger than the age of 5 years (range 0.6%-1.2%), and they can require different clinical treatment strategies compared with fractures in the adult population because of concerns regarding mandibular growth and development of dentition. A 5-year-old girl with a history of falling from a bicycle 7 hours earlier was referred to the department of oral and maxillofacial surgery. Multislice computed tomographic examination demonstrated a bilateral fracture of the mandibular condyle neck associated with minimal fracture of the alveolar ridge of the maxilla. The multislice computed tomographic scan also demonstrated dislocation on the right condyle neck and, on the left side, a medial inclination of approximately 45 degrees associated with greenstick fracture of the right parasymphysis region. In this particular case, orthodontic rubber elastics in combination with fixed orthodontic brackets provided good results in the treatment of bilateral condyle neck fractures associated with greenstick fracture of parasymphysis.

  14. S-values calculated from a tomographic head/brain model for brain imaging

    NASA Astrophysics Data System (ADS)

    Chao, Tsi-chian; Xu, X. George

    2004-11-01

    A tomographic head/brain model was developed from the Visible Human images and used to calculate S-values for brain imaging procedures. This model contains 15 segmented sub-regions including caudate nucleus, cerebellum, cerebral cortex, cerebral white matter, corpus callosum, eyes, lateral ventricles, lenses, lentiform nucleus, optic chiasma, optic nerve, pons and middle cerebellar peduncle, skull CSF, thalamus and thyroid. S-values for C-11, O-15, F-18, Tc-99m and I-123 have been calculated using this model and a Monte Carlo code, EGS4. Comparison of the calculated S-values with those calculated from the MIRD (1999) stylized head/brain model shows significant differences. In many cases, the stylized head/brain model resulted in smaller S-values (as much as 88%), suggesting that the doses to a specific patient similar to the Visible Man could have been underestimated using the existing clinical dosimetry.

  15. In Silico Neuro-Oncology: Brownian Motion-Based Mathematical Treatment as a Potential Platform for Modeling the Infiltration of Glioma Cells into Normal Brain Tissue.

    PubMed

    Antonopoulos, Markos; Stamatakos, Georgios

    2015-01-01

    Intensive glioma tumor infiltration into the surrounding normal brain tissues is one of the most critical causes of glioma treatment failure. To quantitatively understand and mathematically simulate this phenomenon, several diffusion-based mathematical models have appeared in the literature. The majority of them ignore the anisotropic character of diffusion of glioma cells since availability of pertinent truly exploitable tomographic imaging data is limited. Aiming at enriching the anisotropy-enhanced glioma model weaponry so as to increase the potential of exploiting available tomographic imaging data, we propose a Brownian motion-based mathematical analysis that could serve as the basis for a simulation model estimating the infiltration of glioblastoma cells into the surrounding brain tissue. The analysis is based on clinical observations and exploits diffusion tensor imaging (DTI) data. Numerical simulations and suggestions for further elaboration are provided.

  16. Gadolinium-enhanced computed tomographic angiography: current status.

    PubMed

    Rosioreanu, Alex; Alberico, Ronald A; Litwin, Alan; Hon, Man; Grossman, Zachary D; Katz, Douglas S

    2005-01-01

    This article reviews the research to date, as well as our clinical experience from two institutions, on gadolinium-enhanced computed tomographic angiography (gCTA) for imaging the body. gCTA may be an appropriate examination for the small percentage of patients who would benefit from noninvasive vascular imaging, but who have contraindications to both iodinated contrast and magnetic resonance imaging. gCTA is more expensive than CTA with iodinated contrast, due to the dose of gadolinium administered, and gCTA has limitations compared with CTA with iodinated contrast, in that parenchymal organs are not optimally enhanced at doses of 0.5 mmol/kg or lower. However, in our experience, gCTA has been a very useful problem-solving examination in carefully selected patients. With the advent of 16-64 detector CT, in combination with bolus tracking, we believe that the overall dose of gadolinium needed for diagnostic CTA examinations, while relatively high, can be safely administered.

  17. Optical tomographic detection of rheumatoid arthritis with computer-aided classification schemes

    NASA Astrophysics Data System (ADS)

    Klose, Christian D.; Klose, Alexander D.; Netz, Uwe; Beuthan, Jürgen; Hielscher, Andreas H.

    2009-02-01

    A recent research study has shown that combining multiple parameters, drawn from optical tomographic images, leads to better classification results to identifying human finger joints that are affected or not affected by rheumatic arthritis RA. Building up on the research findings of the previous study, this article presents an advanced computer-aided classification approach for interpreting optical image data to detect RA in finger joints. Additional data are used including, for example, maximum and minimum values of the absorption coefficient as well as their ratios and image variances. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index and area under the curve AUC. Results were compared to different benchmarks ("gold standard"): magnet resonance, ultrasound and clinical evaluation. Maximum accuracies (AUC=0.88) were reached when combining minimum/maximum-ratios and image variances and using ultrasound as gold standard.

  18. [Prostatic abscess. Contribution of the x-ray computed tomography. Apropos of a case].

    PubMed

    Husain, A; Touzard, D

    1988-01-01

    We reported a case of prostatic abscess due to staphylococeus aureus developed in a chronic alcoholic patient. The clinical symptoms and signs were largely masked by prior antibiotic therapy. Computed axial tomographic scanning of the pelvis made the diagnosis and demonstrated the resolution of the prostatic abscess following antibiotic therapy and spontaneous rupture to the urethra.

  19. Clinical studies of pigmented lesions in human skin by using a multiphoton tomograph

    NASA Astrophysics Data System (ADS)

    Balu, Mihaela; Kelly, Kristen M.; Zachary, Christopher B.; Harris, Ronald M.; Krasieva, Tatiana B.; König, Karsten; Tromberg, Bruce J.

    2013-02-01

    In vivo imaging of pigmented lesions in human skin was performed with a clinical multiphoton microscopy (MPM)-based tomograph (MPTflex, JenLab, Germany). Two-photon excited fluorescence was used for visualizing endogenous fluorophores such as NADH/FAD, keratin, melanin in the epidermal cells and elastin fibers in the dermis. Collagen fibers were imaged by second harmonic generation. Our study involved in vivo imaging of benign melanocytic nevi, atypical nevi and melanoma. The goal of this preliminary study was to identify in vivo the characteristic features and their frequency in pigmented lesions at different stages (benign, atypical and malignant) and to evaluate the ability of in vivo MPM to distinguish atypical nevi from melanoma. Comparison with histopathology was performed for the biopsied lesions. Benign melanocytic nevi were characterized by the presence of nevus cell nests at the epidermal-dermal junction. In atypical nevi, features such as lentiginous hyperplasia, acanthosis and architectural disorder were imaged. Cytological atypia was present in all the melanoma lesions imaged, showing the strongest correlation with malignancy. The MPM images demonstrated very good correlation with corresponding histological images, suggesting that MPM could be a promising tool for in vivo non-invasive pigmented lesion diagnosis, particularly distinguishing atypical nevi from melanoma.

  20. Prototyping context-aware nursing support mobile system.

    PubMed

    Esashi, Misa; Nakano, Tomohiro; Onose, Nao; Sato, Kikue; Hikita, Tomoko; Hoya, Reiko; Okamoto, Kazuya; Ohboshi, Naoki; Kuroda, Tomohiro

    2016-08-01

    A context aware nursing support system to push right information to the right person at the right moment is the key to increase clinical safety under a computerized hospital. We prototyped a system which obtains context from positions of nurses and list of expected clinical procedures. A WoZ test showed that the proposed approach has potential to decrease incidents caused by information delivery error.

  1. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    PubMed

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing of asymptomatic individuals before the start of a sporting season. This study adds to the evidence that suggests in this population such testing may lack sufficient reliability to support clinical decision making.

  2. Tomographic Imaging of a Forested Area By Airborne Multi-Baseline P-Band SAR.

    PubMed

    Frey, Othmar; Morsdorf, Felix; Meier, Erich

    2008-09-24

    In recent years, various attempts have been undertaken to obtain information about the structure of forested areas from multi-baseline synthetic aperture radar data. Tomographic processing of such data has been demonstrated for airborne L-band data but the quality of the focused tomographic images is limited by several factors. In particular, the common Fourierbased focusing methods are susceptible to irregular and sparse sampling, two problems, that are unavoidable in case of multi-pass, multi-baseline SAR data acquired by an airborne system. In this paper, a tomographic focusing method based on the time-domain back-projection algorithm is proposed, which maintains the geometric relationship between the original sensor positions and the imaged target and is therefore able to cope with irregular sampling without introducing any approximations with respect to the geometry. The tomographic focusing quality is assessed by analysing the impulse response of simulated point targets and an in-scene corner reflector. And, in particular, several tomographic slices of a volume representing a forested area are given. The respective P-band tomographic data set consisting of eleven flight tracks has been acquired by the airborne E-SAR sensor of the German Aerospace Center (DLR).

  3. Computed tomographic findings and treatment of a bull with pituitary gland abscess.

    PubMed

    Braun, Ueli; Malbon, Alexandra; Kochan, Manon; Riond, Barbara; Janett, Fredi; Iten, Cornelia; Dennler, Matthias

    2017-01-13

    In cattle, the prognosis of brain abscess is unfavourable and treatment is therefore not recommended. To the knowledge of the authors, there has been no report of successful treatment of a brain abscess in cattle.This report describes the clinical, computed tomographic and postmortem findings in a Holstein-Friesian bull with a hypophyseal abscess. The main clinical findings were generalised ataxia, ptyalism, prolapse of the tongue, dropped jaw, dysphagia, head tilt and unilateral ptosis. Cerebrospinal fluid evaluation revealed 2437 leukocytes/µl and severe pleocytosis. CT examination of the head showed a cavitary lesion consistent with an abscess in the hypophysis. Treatment consisted of gentamicin and flunixin meglumine for 3 days and amoxicillin for 40 days. The neurological signs resolved within 8 days of the start of treatment. The bull was slaughtered 11 months later because of infertility, and a postmortem examination was carried out. Histologically, a mild chronic non suppurative meningoencephalitis restricted to the ventral diencephalon was diagnosed. In addition, there was mild to moderate multifocal chronic lymphoplasmacytic hypophysitis with mild multifocal fibrosis. This case report stresses the significance of CT in confirming the clinical and laboratory diagnosis of central nervous system disorders in cattle and for localising brain lesions. Treatment of the brain abscess resulted, with respect to the central nervous disorder, in a successful outcome and was encouraging considering that most cases have an unfavourable prognosis.

  4. Assessment of minimal hepatic encephalopathy (with emphasis on computerized psychometric tests).

    PubMed

    Kappus, Matthew R; Bajaj, Jasmohan S

    2012-02-01

    Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life, and driving accidents. The detection of MHE requires specialized testing because it cannot, by definition, be diagnosed on standard clinical examination. Psychometric and neurophysiologic techniques are often used to test for MHE. Paper-pencil psychometric batteries and computerized tests have proved useful in diagnosing MHE and predicting its outcomes. Neurophysiologic tests also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike. Testing strategies depend on the normative data available, patient comfort, and local expertise. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. CT diagnosis of a clinically unsuspected acute appendicitis complicating infectious mononucleosis.

    PubMed

    Zissin, R; Brautbar, O; Shapiro-Feinberg, M

    2001-01-01

    Acute appendicitis is a rare complication of infectious mononucleosis (IM). We describe a patient with IM and splenic rupture with a computerized tomography (CT) diagnosis of acute appendicitis during the acute phase of the infectious disease. Diagnostic imaging features of acute appendicitis were found on an abdominal CT performed for the evaluation of postoperative fever. Histologic examination confirmed the CT diagnosis of the clinically unsuspected acute appendicitis. Our case is unique both for the rarity of this complication and the lack of clinical symptoms.

  6. Clinical and instrumental treatment of a patient with dysfunction of the stomatognathic system: a case report

    PubMed Central

    Baldini, Alberto

    2010-01-01

    Summary This article details a case report of a subject chosen from among patients treated in the author’s clinic in the Posturology and Gnathology Section of the University Milano-Bicocca. It shows how the indispensable clinical analysis of the stomatognathic system and the connections between posture can be supported by instrumental analysis, such as the computerized occlusal analysis system and the force platform, to diagnose and treat dysfunctional patients. PMID:22238703

  7. Out of sight, out of mind? Does terminating the physical presence of a geriatric consultant in the community clinic reduce the implementation rate for geriatric recommendations.

    PubMed

    Freud, Tamar; Punchik, Boris; Biderman, Aya; Peleg, Roni; Kagan, Ella; Barzak, Alex; Press, Yan

    2016-01-01

    To assess the effect of moving the geriatric consultation from the primary care clinic to another setting, on the rate of implementation of geriatric recommendations by family physicians. A retrospective review of the computerized medical records of elderly patients in four primary care clinics. The rate of implementation of geriatric recommendations was compared between clinics in which a geriatric consultant was physically present (control clinics) and a clinic where the consultation took place elsewhere (study clinic). In addition, the results of the present study were compared to a previous study in which the geriatric consultation was carried out in the study clinic and the family doctor was an active participant. 127 computerized files were reviewed in the study clinic and 133 in the control clinics. The mean age of the patients was 81.1±6.3 years and 63.1% were women. The overall implementation of geriatric recommendations by family doctors in the study clinic was 55.9%, a statistically significant decrease compared to the previous study where the rate was 73.9% (p<0.0001). In contrast, there was no change in the implementation rate in the control clinics at 65.0% in the present study and 59.9% in the previous one (p=0.205). Direct, person-to-person contact between the geriatric consultant and the family doctor has a beneficial effect on the implementation of geriatric recommendations. This should be considered by healthcare policy makers when planning geriatric services in the community. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. A survey of medical informatics in Belgium.

    PubMed

    Roger, F H; Behets, M; Andre, J; de Moor, G; Sevens, C; Willems, J L

    1987-01-01

    The Belgian Society for Medical Informatics (MIM) organized a survey in 1986 in order to assess the present state of development of medical informatics in Belgium. Questionnaires were sent to hospitals, laboratories, private practitioners and pharmacists, as well as to social security organizations and software industries. The response rate was higher in hospitals (93%) than in any other category. Results showed a large number of computerized hospitals (93% of general acute care hospitals and 91% of psychiatric hospitals). There has been a sharp increase (+ 15%) in computerization of the admission, accounting and billing procedures since 1985, most likely in relation with administrative rules issued by the Belgian Government. The same trend (+ 20%) has been observed for computer applications in clinical laboratories, between 1984 and 1985. There is almost one computer terminal for ten beds in the hospitals with more than 200 beds in 1986. This figure exemplifies the present trend to on-line access to data. Computerized instrumental aids to medicine such as text processing, imaging or computerized interpretation of signals have known a rapid extension during recent years, although less comprehensive than administrative applications in hospitals and in social security organizations. The present state of other applications in medicine (general practice, pharmacy, etc.) was more difficult to assess as those information systems remain more pinpointed. In all medical fields, there appears to be a new rise in computer programs offered by software companies.

  9. Diabetes Information Technology: Designing Informatics Systems to Catalyze Change in Clinical Care

    PubMed Central

    Lester, William T.; Zai, Adrian H.; Chueh, Henry C.; Grant, Richard W.

    2008-01-01

    Current computerized reminder and decision support systems intended to improve diabetes care have had a limited effect on clinical outcomes. Increasing pressures on health care networks to meet standards of diabetes care have created an environment where information technology systems for diabetes management are often created under duress, appended to existing clinical systems, and poorly integrated into the existing workflow. After defining the components of diabetes disease management, the authors present an eight-step conceptual framework to guide the development of more effective diabetes information technology systems for translating clinical information into clinical action. PMID:19885355

  10. COMPUTERIZED NEEDS-ORIENTED QUALITY MEASUREMENT EVALUATION SYSTEM (CONQUEST)

    EPA Science Inventory

    CONQUEST is an easy-to-use quality improvement software tool that uses a common structure and language to help users identity, understand, compare, evaluate, and select among 1,200 clinical performance measures that can be used to assess and improve quality of care. CONQUEST's in...

  11. Privacy considerations in the context of an Australian observational database.

    PubMed

    Duszynski, K M; Beilby, J J; Marley, J E; Walker, D C; Pratt, N L

    2001-12-01

    Observational databases are increasingly acknowledged for their value in clinical investigation. Australian general practice in particular presents an exciting opportunity to examine treatment in a natural setting. The paper explores issues such as privacy and confidentiality--foremost considerations when conducting this form of pharmacoepidemiological research. Australian legislation is currently addressing these exact issues in order to establish clear directives regarding ethical concerns. The development of a pharmacoepidemiological database arising from the integration of computerized Australian general practice records is described in addition, to the challenges associated with creating a database which considers patient privacy. The database known as 'Medic-GP', presently contains more than 950,000 clinical notes (including consultations, pathology, diagnostic imaging and adverse reactions) over a 5-year time period and relates to 55,000 patients. The paper then details a retrospective study which utilized the database to examine the interaction between antibiotic prescribing and patient outcomes from a community perspective, following a policy intervention. This study illustrates the application of computerized general practice records in research.

  12. Computerization of a preanesthetic evaluation and user satisfaction evaluation.

    PubMed

    Arias, Antonio; Benítez, Sonia; Canosa, Daniela; Borbolla, Damián; Staccia, Gustavo; Plazzotta, Fernando; Casais, Marcela; Michelangelo, Hernán; Luna, Daniel; Bernaldo de Quirós, Fernán Gonzalez

    2010-01-01

    Preanesthetic evaluation purpose is to reduce morbidity and mortality through the review of the patient's medical history, clinical examination, and targeted clinical studies, providing referrals for medical consultations when appropriated. Changes in patient care, standards of health information management and patterns of perioperative care, have resulted in a re-conceptualization of this process where the documentation of patient medical information, the efforts in training and maintaining the integrity of the medical-legal evaluation are areas of concern. The aim of this paper is to describe the design, development, training, and implementation of a computerized preanesthetic evaluation form associated to the evaluation of the user satisfaction with the system. Since the system went live in September 2008 there were 15121 closed structured forms, 60% for ambulatory procedures and 40 % for procedures that required hospital admission. 82% of total closed structured forms had recorded a risk of the procedures of 1-2, according to the American Society of Anesthesiologists classification. The survey indicates a positive general satisfaction of the users with the system.

  13. Accurately Diagnosing Uric Acid Stones from Conventional Computerized Tomography Imaging: Development and Preliminary Assessment of a Pixel Mapping Software.

    PubMed

    Ganesan, Vishnu; De, Shubha; Shkumat, Nicholas; Marchini, Giovanni; Monga, Manoj

    2018-02-01

    Preoperative determination of uric acid stones from computerized tomography imaging would be of tremendous clinical use. We sought to design a software algorithm that could apply data from noncontrast computerized tomography to predict the presence of uric acid stones. Patients with pure uric acid and calcium oxalate stones were identified from our stone registry. Only stones greater than 4 mm which were clearly traceable from initial computerized tomography to final composition were included in analysis. A semiautomated computer algorithm was used to process image data. Average and maximum HU, eccentricity (deviation from a circle) and kurtosis (peakedness vs flatness) were automatically generated. These parameters were examined in several mathematical models to predict the presence of uric acid stones. A total of 100 patients, of whom 52 had calcium oxalate and 48 had uric acid stones, were included in the final analysis. Uric acid stones were significantly larger (12.2 vs 9.0 mm, p = 0.03) but calcium oxalate stones had higher mean attenuation (457 vs 315 HU, p = 0.001) and maximum attenuation (918 vs 553 HU, p <0.001). Kurtosis was significantly higher in each axis for calcium oxalate stones (each p <0.001). A composite algorithm using attenuation distribution pattern, average attenuation and stone size had overall 89% sensitivity, 91% specificity, 91% positive predictive value and 89% negative predictive value to predict uric acid stones. A combination of stone size, attenuation intensity and attenuation pattern from conventional computerized tomography can distinguish uric acid stones from calcium oxalate stones with high sensitivity and specificity. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Canadian adaptation of the Newest Vital Sign©, a health literacy assessment tool.

    PubMed

    Mansfield, Elizabeth D; Wahba, Rana; Gillis, Doris E; Weiss, Barry D; L'Abbé, Mary

    2018-04-25

    The Newest Vital Sign© (NVS) was developed in the USA to measure patient health literacy in clinical settings. We adapted the NVS for use in Canada, in English and French, and created a computerized version. Our objective was to evaluate the reliability of the Canadian NVS as a self-administered computerized tool. We used a randomized crossover design with a washout period of 3-4 weeks to compare health literacy scores obtained using the computerized version with scores obtained using the standard interviewer-administered NVS. ANOVA models and McNemar's tests assessed differences in outcomes assessed with each version of the NVS and order effects of the testing. Participants were recruited from multicultural catchment areas in Ontario and Nova Scotia. English- and French-speaking adults aged 18 years or older. A total of 180 (81 %) of the 222 adults (112 English/110 French) initially recruited completed both the interviewer-NVS and computer-NVS. Scores for those who completed both assessments ranged from 0 to 6 with a mean of 3·63 (sd 2·11) for the computerized NVS and 3·41 (sd 2·21) for the interview-administered NVS. Few (n 18; seven English, eleven French) participants' health literacy assessments differed between the two versions. Overall, the computerized Canadian NVS performed as well as the interviewer-administered version for assessing health literacy levels of English- and French-speaking participants. This Canadian adaptation of the NVS provides Canadian researchers and public health practitioners with an easily administered health literacy assessment tool that can be used to address the needs of Canadians across health literacy levels and ultimately improve health outcomes.

  15. Tomographic Reconstruction from a Few Views: A Multi-Marginal Optimal Transport Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abraham, I., E-mail: isabelle.abraham@cea.fr; Abraham, R., E-mail: romain.abraham@univ-orleans.fr; Bergounioux, M., E-mail: maitine.bergounioux@univ-orleans.fr

    2017-02-15

    In this article, we focus on tomographic reconstruction. The problem is to determine the shape of the interior interface using a tomographic approach while very few X-ray radiographs are performed. We use a multi-marginal optimal transport approach. Preliminary numerical results are presented.

  16. Traditional medicine in the treatment of drug addiction.

    PubMed

    Lu, Lin; Liu, Yanli; Zhu, Weili; Shi, Jie; Liu, Yu; Ling, Walter; Kosten, Thomas R

    2009-01-01

    To evaluate clinical trials and neurochemical mechanisms of the action of traditional herbal remedies and acupuncture for treating drug addiction. We used computerized literature searches in English and Chinese and examined texts written before these computerized databases existed. We used search terms of treatment and neurobiology of herbal medicines, and acupuncture for drug abuse and dependence. Acupuncture showed evidence for clinical efficacy and relevant neurobiological mechanisms in opiate withdrawal, but it showed poor efficacy for alcohol and nicotine withdrawal or relapse prevention, and no large studies supported its efficacy for cocaine in well-designed clinical trials. Clinical trials were rare for herbal remedies. Radix Puerariae showed the most promising efficacy for alcoholism by acting through daidzin, which inhibits mitocochondrial aldehyde dehydrogenase 2 and leads to disulfiram-like alcohol reactions. Peyote also has some evidence for alcoholism treatment among Native Americans. Ginseng and Kava lack efficacy data in addictions, and Kava can be hepatotoxic. Thunbergia laurifolia can protect against alcoholic liver toxicity. Withania somnifera and Salvia miltiorrhiza have no efficacy data, but can reduce morphine tolerance and alcohol intake, respectively, in animal models. Traditional herbal treatments can compliment pharmacotherapies for drug withdrawal and possibly relapse prevention with less expense and perhaps fewer side effects with notable exceptions. Both acupuncture and herbal treatments need testing as adjuncts to reduce doses and durations of standard pharmacotherapies.

  17. Optical skin biopsies by clinical CARS and multiphoton fluorescence/SHG tomography

    NASA Astrophysics Data System (ADS)

    König, K.; Breunig, H. G.; Bückle, R.; Kellner-Höfer, M.; Weinigel, M.; Büttner, E.; Sterry, W.; Lademann, J.

    2011-06-01

    The ultimate challenge for early diagnostics is label-free high-resolution intratissue imaging without taking physical biopsies. A novel hybrid femtosecond laser tomograph provides in vivo optical biopsies of human skin based on non-linear excitation of autofluorescence and the detection of lipids and water by CARS. Applications include skin cancer detection, biosafety tests of intradermal nanoparticles, and the testing of anti-aging products.

  18. Clinical Investigation Program.

    DTIC Science & Technology

    1981-10-01

    Tomographic (CT) Appearance of the ryc- cardium After Neversible and Irreversible Ischemic Injury . 29th Annual Meeting of the Association of University...Orthopedic Surgeons, San Antonio, TX, Nov 1980. (C) Greenfield, G. Q., Jr.: Injuries Related to Rollerskating. Annual Mleeting, Society of Military...volume reduction odiumw balance A c-umuatie-.EDLASE I E st Ac cumul a ti ye Perio -di-c ............ Lost: LOA Cost: $1LO0. Review Results: Continue

  19. Clinical outcomes of fractional flow reserve by computed tomographic angiography-guided diagnostic strategies vs. usual care in patients with suspected coronary artery disease: the prospective longitudinal trial of FFR(CT): outcome and resource impacts study.

    PubMed

    Douglas, Pamela S; Pontone, Gianluca; Hlatky, Mark A; Patel, Manesh R; Norgaard, Bjarne L; Byrne, Robert A; Curzen, Nick; Purcell, Ian; Gutberlet, Matthias; Rioufol, Gilles; Hink, Ulrich; Schuchlenz, Herwig Walter; Feuchtner, Gudrun; Gilard, Martine; Andreini, Daniele; Jensen, Jesper M; Hadamitzky, Martin; Chiswell, Karen; Cyr, Derek; Wilk, Alan; Wang, Furong; Rogers, Campbell; De Bruyne, Bernard

    2015-12-14

    In symptomatic patients with suspected coronary artery disease (CAD), computed tomographic angiography (CTA) improves patient selection for invasive coronary angiography (ICA) compared with functional testing. The impact of measuring fractional flow reserve by CTA (FFRCT) is unknown. At 11 sites, 584 patients with new onset chest pain were prospectively assigned to receive either usual testing (n = 287) or CTA/FFR(CT) (n = 297). Test interpretation and care decisions were made by the clinical care team. The primary endpoint was the percentage of those with planned ICA in whom no significant obstructive CAD (no stenosis ≥50% by core laboratory quantitative analysis or invasive FFR < 0.80) was found at ICA within 90 days. Secondary endpoints including death, myocardial infarction, and unplanned revascularization were independently and blindly adjudicated. Subjects averaged 61 ± 11 years of age, 40% were female, and the mean pre-test probability of obstructive CAD was 49 ± 17%. Among those with intended ICA (FFR(CT)-guided = 193; usual care = 187), no obstructive CAD was found at ICA in 24 (12%) in the CTA/FFR(CT) arm and 137 (73%) in the usual care arm (risk difference 61%, 95% confidence interval 53-69, P< 0.0001), with similar mean cumulative radiation exposure (9.9 vs. 9.4 mSv, P = 0.20). Invasive coronary angiography was cancelled in 61% after receiving CTA/FFR(CT) results. Among those with intended non-invasive testing, the rates of finding no obstructive CAD at ICA were 13% (CTA/FFR(CT)) and 6% (usual care; P = 0.95). Clinical event rates within 90 days were low in usual care and CTA/FFR(CT) arms. Computed tomographic angiography/fractional flow reserve by CTA was a feasible and safe alternative to ICA and was associated with a significantly lower rate of invasive angiography showing no obstructive CAD. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  20. Assessment of Minimal HE (with emphasis on computerized psychometric tests)

    PubMed Central

    Kappus, Matthew R; Bajaj, Jasmohan S

    2012-01-01

    Synopsis Minimal hepatic encephalopathy (MHE) is associated with a high risk of development of overt hepatic encephalopathy, impaired quality of life and driving accidents. The detection of MHE requires specialized testing since it cannot by definition, be diagnosed on standard clinical examination. Psychometric (paper-pencil or computerized or a combination) and neuro-physiological techniques are often used to test for MHE. Paper-pencil psychometric batteries like the Psychometric Hepatic Encephalopathy Score (PHES) have been validated in several countries but do not have US normative values. Computerized tests such as the inhibitory control test (ICT), cognitive drug research system and Scan test have proven useful to diagnose MHE and predict outcomes. The specificity and sensitivity of these tests are similar to the recommended gold standards. Neuro-physiological tests such as the EEG and its interpretations, evoked potentials and Critical Flicker Frequency (CFF) also provide useful information. The diagnosis of MHE is an important issue for clinicians and patients alike and the testing strategies depend on the normative data available, patient comfort and local expertise. PMID:22321464

  1. Diabetes education kiosks in a latino community.

    PubMed

    Bolin, Jane N; Ory, Marcia G; Wilson, Ashley D; Salge, Lesley

    2013-01-01

    The purpose of this study was to examine the implementation, use, and sustainability of a computerized touch-screen diabetes education kiosk (Diosk) designed to provide "on-demand" education in a predominantly Latino community in South Texas. A pilot study was conducted to examine the implementation, use, and sustainability of the Diosk in 5 settings (e.g., clinics, community centers, and pharmacies) serving low-income, low-literacy populations. Both quantitative and qualitative data from embedded computerized usage tracking, user surveys, and key stakeholder interviews were collected and analyzed using descriptive statistics. RESULTS; There were more than 5300 uses of the Diosk in the different sites during the 11-month study. The majority of users were female, between the ages of 36 and 64 years, and Latino, and they identified themselves as having or being at risk for type 2 diabetes. Several challenges were faced in maintaining the Diosk during the study, such as organizational capacity to host wireless Internet and establishing "office champions" responsible for overseeing the Diosk. At the end of the study, 3 of the 5 sites committed to sustaining the Diosk on their own. This pilot study testing the feasibility and acceptability of the Diosk demonstrated that a Diosk can be implemented, used, and sustained in a population with high rates of diabetes and limited prior use of disease management programs. Computerized technology offers one solution to expanding the reach of diabetes education through easily accessible community and clinical settings.

  2. Computerized pharmacy surveillance and alert system for drug-related problems.

    PubMed

    Ferrández, O; Urbina, O; Grau, S; Mateu-de-Antonio, J; Marin-Casino, M; Portabella, J; Mojal, S; Riu, M; Salas, E

    2017-04-01

    Because of the impact of drug-related problems (DRPs) on morbidity and mortality, there is a need for computerized strategies to increase drug safety. The detection and identification of the causes of potential DRPs can be facilitated by the incorporation of a pharmacy warning system (PWS) in the computerized prescriber order entry (CPOE) and its application in the routine validation of inpatient drug therapy. A limited number of studies have evaluated a clinical decision support system to monitor drug treatment. Most of these applications have utilized a small range of drugs with alerts and/or types of alert. The objective of this study was to describe the implementation of a PWS integrated in the electronic medical record (EMR). The PWS was developed in 2003-2004. Pharmacological information to generate drug alerts was entered on demographic data, drug dosage, laboratory tests related to the prescribed drug and drug combinations (interactions, duplications and necessary combinations). The PWS was applied in the prescription reviews conducted in patients admitted to the hospital in 2012. Information on 83% of the drugs included in the pharmacopeia was introduced into the PWS, allowing detection of 2808 potential DRPs, representing 79·1% of all potential DRPs detected during the study period. Twenty per cent of PWS DRPs were clinically relevant, requiring pharmacist intervention. The PWS detected most potential DRPs, thus increasing inpatient safety. The detection ability of the PWS was higher than that reported for other tools described in the literature. © 2017 John Wiley & Sons Ltd.

  3. Integrated Psychosocial and Opioid-Antagonist Treatment for Alcohol Dependence: A Systematic Review of Controlled Evaluations

    ERIC Educational Resources Information Center

    Vaughn, Michael G.; Howard, Matthew O.

    2004-01-01

    Methodological characteristics and outcomes of 14 controlled clinical investigations of integrated psychosocial and opioid-antagonist alcohol dependence treatment were evaluated. The 14 studies were identified through computerized bibliographic and manual literature searches. Clients receiving integrated psychosocial and opioid-antagonist…

  4. Humanizing Assessment Reports with a Computer.

    ERIC Educational Resources Information Center

    Mathews, Walter M.

    Five computerized narrative assessment reports are discussed. These are: (1) the Teaching Information Processing System Student Report, used for a college economics course; (2) the Preliminary Scholastic Aptitude Test (PSAT) Score Report; (3) the Programmed Composition of Psychological Test Reports employed at the Mayo Clinic for reporting results…

  5. FDDI information management system for centralizing interactive, computerized multimedia clinical experiences in pediatric rheumatology/Immunology.

    PubMed

    Rouhani, R; Cronenberger, H; Stein, L; Hannum, W; Reed, A M; Wilhelm, C; Hsiao, H

    1995-01-01

    This paper describes the design, authoring, and development of interactive, computerized, multimedia clinical simulations in pediatric rheumatology/immunology and related musculoskeletal diseases, the development and implementation of a high speed information management system for their centralized storage and distribution, and analytical methods for evaluating the total system's educational impact on medical students and pediatric residents. An FDDI fiber optic network with client/server/host architecture is the core. The server houses digitized audio, still-image video clips and text files. A host station houses the DB2/2 database containing case-associated labels and information. Cases can be accessed from any workstation via a customized interface in AVA/2 written specifically for this application. OS/2 Presentation Manager controls, written in C, are incorporated into the interface. This interface allows SQL searches and retrievals of cases and case materials. In addition to providing user-directed clinical experiences, this centralized information management system provides designated faculty with the ability to add audio notes and visual pointers to image files. Users may browse through case materials, mark selected ones and download them for utilization in lectures or for editing and converting into 35mm slides.

  6. Versatile clinical information system design for emergency departments.

    PubMed

    Amouh, Teh; Gemo, Monica; Macq, Benoît; Vanderdonckt, Jean; El Gariani, Abdul Wahed; Reynaert, Marc S; Stamatakis, Lambert; Thys, Frédéric

    2005-06-01

    Compared to other hospital units, the emergency department presents some distinguishing characteristics of its own. Emergency health-care delivery is a collaborative process involving the contribution of several individuals who accomplish their tasks while working autonomously under pressure and sometimes with limited resources. Effective computerization of the emergency department information system presents a real challenge due to the complexity of the scenario. Current computerized support suffers from several problems, including inadequate data models, clumsy user interfaces, and poor integration with other clinical information systems. To tackle such complexity, we propose an approach combining three points of view, namely the transactions (in and out of the department), the (mono and multi) user interfaces and data management. Unlike current systems, we pay particular attention to the user-friendliness and versatility of our system. This means that intuitive user interfaces have been conceived and specific software modeling methodologies have been applied to provide our system with the flexibility and adaptability necessary for the individual and group coordinated tasks. Our approach has been implemented by prototyping a web-based, multiplatform, multiuser, and versatile clinical information system built upon multitier software architecture, using the Java programming language.

  7. Reliability and Criterion Validity of a Novel Clinical Test of Simple and Complex Reaction Time in Athletes1

    PubMed Central

    Eckner, James T.; Richardson, James K.; Kim, Hogene; Joshi, Monica S.; Oh, Youkeun K.; Ashton-Miller, James A.

    2015-01-01

    Summary Slowed reaction time (RT) represents both a risk factor for and a consequence of sport concussion. The purpose of this study was to determine the reliability and criterion validity of a novel clinical test of simple and complex RT, called RTclin, in contact sport athletes. Both tasks were adapted from the well-known ruler drop test of RT and involve manually grasping a falling vertical shaft upon its release, with the complex task employing a go/no-go paradigm based on a slight cue. In 46 healthy contact sport athletes (24 males; M = 16.3 yr., SD = 5.0; 22 women: M age= 15.0 yr., SD = 4.0) whose sports included soccer, ice hockey, American football, martial arts, wrestling, and lacrosse, the latency and accuracy of simple and complex RTclin had acceptable test-retest and inter-rater reliabilities and correlated with a computerized criterion standard, the Axon Computerized Cognitive Assessment Tool. Medium to large effect sizes were found. The novel RTclin tests have acceptable reliability and criterion validity for clinical use and hold promise as concussion assessment tools. PMID:26106803

  8. Sarcoidosis Occurring After Lymphoma

    PubMed Central

    London, Jonathan; Grados, Aurélie; Fermé, Christophe; Charmillon, Alexandre; Maurier, François; Deau, Bénédicte; Crickx, Etienne; Brice, Pauline; Chapelon-Abric, Catherine; Haioun, Corinne; Burroni, Barbara; Alifano, Marco; Le Jeunne, Claire; Guillevin, Loïc; Costedoat-Chalumeau, Nathalie; Schleinitz, Nicolas; Mouthon, Luc; Terrier, Benjamin

    2014-01-01

    Abstract Sarcoidosis is a granulomatous disease that most frequently affects the lungs with pulmonary infiltrates and/or bilateral hilar and mediastinal lymphadenopathy. An association of sarcoidosis and lymphoproliferative disease has previously been reported as the sarcoidosis-lymphoma syndrome. Although this syndrome is characterized by sarcoidosis preceding lymphoma, very few cases of sarcoidosis following lymphoma have been reported. We describe the clinical, biological, and radiological characteristics and outcome of 39 patients presenting with sarcoidosis following lymphoproliferative disease, including 14 previously unreported cases and 25 additional patients, after performing a literature review. Hodgkin lymphoma and non-Hodgkin lymphoma were equally represented. The median delay between lymphoma and sarcoidosis was 18 months. Only 16 patients (41%) required treatment. Sarcoidosis was of mild intensity or self-healing in most cases, and overall clinical response to sarcoidosis was excellent with complete clinical response in 91% of patients. Sarcoidosis was identified after a follow-up computerized tomography scan (CT-scan) or 18fluorodeoxyglucose-positron emission tomography/computerized tomography (18FDG-PET/CT) evaluation in 18/34 patients (53%). Sarcoidosis is therefore a differential diagnosis to consider when lymphoma relapse is suspected on a CT-scan or 18FDG-PET/CT, emphasizing the necessity to rely on histological confirmation of lymphoma relapse. PMID:25380084

  9. Computerized Cuff Pressure Algometry as Guidance for Circumferential Tissue Compression for Wearable Soft Robotic Applications: A Systematic Review.

    PubMed

    Kermavnar, Tjaša; Power, Valerie; de Eyto, Adam; O'Sullivan, Leonard W

    2018-02-01

    In this article, we review the literature on quantitative sensory testing of deep somatic pain by means of computerized cuff pressure algometry (CPA) in search of pressure-related safety guidelines for wearable soft exoskeleton and robotics design. Most pressure-related safety thresholds to date are based on interface pressures and skin perfusion, although clinical research suggests the deep somatic tissues to be the most sensitive to excessive loading. With CPA, pain is induced in deeper layers of soft tissue at the limbs. The results indicate that circumferential compression leads to discomfort at ∼16-34 kPa, becomes painful at ∼20-27 kPa, and can become unbearable even below 40 kPa.

  10. System and method for generating motion corrected tomographic images

    DOEpatents

    Gleason, Shaun S [Knoxville, TN; Goddard, Jr., James S.

    2012-05-01

    A method and related system for generating motion corrected tomographic images includes the steps of illuminating a region of interest (ROI) to be imaged being part of an unrestrained live subject and having at least three spaced apart optical markers thereon. Simultaneous images are acquired from a first and a second camera of the markers from different angles. Motion data comprising 3D position and orientation of the markers relative to an initial reference position is then calculated. Motion corrected tomographic data obtained from the ROI using the motion data is then obtained, where motion corrected tomographic images obtained therefrom.

  11. [The clinical and X-ray classification of osteonecrosis of the low jaw].

    PubMed

    Medvedev, Iu A; Basin, E M; Sokolina, I A

    2013-01-01

    To elaborate a clinical and X-ray classification of osteonecrosis of the low jaw in people with desomorphine or pervitin addiction. Ninety-two patients with drug addiction who had undergone orthopantomography, direct frontal X-ray of the skull, and multislice computed tomography, followed by multiplanar and three-dimensional imaging reconstruction were examined. One hundred thirty four X-ray films and 74 computed tomographic images were analyzed. The authors proposed a clinical and X-ray classification of osteonecrosis of the low jaw in people with desomorphine or pervitin addiction and elaborated recommendations for surgical interventions on the basis of the developed classification. The developed clinical and X-ray classification and recommendations for surgical interventions may be used to treat osteonecroses of various etiology.

  12. Optical tomographic memories: algorithms for the efficient information readout

    NASA Astrophysics Data System (ADS)

    Pantelic, Dejan V.

    1990-07-01

    Tomographic alogithms are modified in order to reconstruct the inf ormation previously stored by focusing laser radiation in a volume of photosensitive media. Apriori information about the position of bits of inf ormation is used. 1. THE PRINCIPLES OF TOMOGRAPHIC MEMORIES Tomographic principles can be used to store and reconstruct the inf ormation artificially stored in a bulk of a photosensitive media 1 The information is stored by changing some characteristics of a memory material (e. g. refractive index). Radiation from the two independent light sources (e. g. lasers) is f ocused inside the memory material. In this way the intensity of the light is above the threshold only in the localized point where the light rays intersect. By scanning the material the information can be stored in binary or nary format. When the information is stored it can be read by tomographic methods. However the situation is quite different from the classical tomographic problem. Here a lot of apriori information is present regarding the p0- sitions of the bits of information profile representing single bit and a mode of operation (binary or n-ary). 2. ALGORITHMS FOR THE READOUT OF THE TOMOGRAPHIC MEMORIES Apriori information enables efficient reconstruction of the memory contents. In this paper a few methods for the information readout together with the simulation results will be presented. Special attention will be given to the noise considerations. Two different

  13. Review of the Scientific Evidence of Using Population Normative Values for Post-Concussive Computerized Neurocognitive Assessments

    DTIC Science & Technology

    2016-02-10

    from clinical, sports , and combat concussions. Rehabilitation Research and Practice. 2012:371970. 61. Fazio VC, Lovell MR, Pardini JE, Collins MW...study conducted by Van Kampen et al in 2006 investigated the role of neurocognitive testing in athletes following sports -related mTBI. The researchers ...learned from clinical, sports , and combat concussions. Rehabilitation Research and Practice. 2012. 87. Iverson G. Key Areas for Future Research . In

  14. Internet-Based Cervical Cytology Screening System

    DTIC Science & Technology

    2007-04-01

    approaches to cervical cancer screening possible. In addition, advances in information technology have facilitated the Internet transmission and archival...processes in the clinical laboratory. Recent technological advances in specimen preparation and computerized primary screening make automated...AD_________________ Award Number: W81XWH-04-C-0083 TITLE: Internet -Based Cervical Cytology

  15. Test-Retest Reliability of Computerized, Everyday Memory Measures and Traditional Memory Tests.

    ERIC Educational Resources Information Center

    Youngjohn, James R.; And Others

    Test-retest reliabilities and practice effect magnitudes were considered for nine computer-simulated tasks of everyday cognition and five traditional neuropsychological tests. The nine simulated everyday memory tests were from the Memory Assessment Clinic battery as follows: (1) simple reaction time while driving; (2) divided attention (driving…

  16. An Antibiotic Resource Program for Students of the Health Professions.

    ERIC Educational Resources Information Center

    Tritz, Gerald J.

    1986-01-01

    Provides a description of a computer program developed to supplement instruction in testing of antibiotics on clinical isolates of microorganisms. The program is a simulation and database for interpretation of experimental data designed to enhance laboratory learning and prepare future physicians to use computerized diagnostic instrumentation and…

  17. Debriefing after Human Patient Simulation and Nursing Students' Learning

    ERIC Educational Resources Information Center

    Benhuri, Gloria

    2014-01-01

    Human Patient Simulation (HPS) exercises with life-like computerized manikins provide clinical experiences for nursing students in a safe environment followed by debriefing that promotes learning. Quantitative research in techniques to support learning from debriefing is limited. The purpose of the quantitative quasi-experimental study using a…

  18. Digital Data Collection and Analysis: Application for Clinical Practice

    ERIC Educational Resources Information Center

    Ingram, Kelly; Bunta, Ferenc; Ingram, David

    2004-01-01

    Technology for digital speech recording and speech analysis is now readily available for all clinicians who use a computer. This article discusses some advantages of moving from analog to digital recordings and outlines basic recording procedures. The purpose of this article is to familiarize speech-language pathologists with computerized audio…

  19. Comparison of Automated Scoring Methods for a Computerized Performance Assessment of Clinical Judgment

    ERIC Educational Resources Information Center

    Harik, Polina; Baldwin, Peter; Clauser, Brian

    2013-01-01

    Growing reliance on complex constructed response items has generated considerable interest in automated scoring solutions. Many of these solutions are described in the literature; however, relatively few studies have been published that "compare" automated scoring strategies. Here, comparisons are made among five strategies for…

  20. Measuring Attention in the Hemispheres: The Lateralized Attention Network Test (LANT)

    ERIC Educational Resources Information Center

    Greene, Deanna J.; Barnea, Anat; Herzberg, Kristin; Rassis, Anat; Neta, Maital; Raz, Amir; Zaidel, Eran

    2008-01-01

    The attention network test (ANT) is a brief computerized battery measuring three independent behavioral components of attention: Conflict resolution (ability to overcome distracting stimuli), spatial Orienting (the benefit of valid spatial pre-cues), and Alerting (the benefit of temporal pre-cues). Imaging, clinical, and behavioral evidence…

  1. Controlled Trial Using Computerized Feedback to Improve Physicians' Diagnostic Judgments.

    ERIC Educational Resources Information Center

    Poses, Roy M.; And Others

    1992-01-01

    A study involving 14 experienced physicians investigated the effectiveness of a computer program (providing statistical feedback to teach a clinical diagnostic rule that predicts the probability of streptococcal pharyngitis), in conjunction with traditional lecture and periodic disease-prevalence reports. Results suggest the integrated method is a…

  2. Computer-aided design evaluation of harvestable mandibular bone volume: a clinical and tomographic human study.

    PubMed

    Verdugo, Fernando; Simonian, Krikor; Raffaelli, Luca; D'Addona, Antonio

    2014-06-01

    To evaluate and compare the volume of bone graft material that can be safely harvested from the mandibular symphysis and rami using a computer-aided design (CAD) software program. Preoperative computerized tomography scans from 40 patients undergoing bone augmentation procedures were analyzed. Symphysis and rami cross sections were mapped using a CAD software program (AutoCAD(®), Autodesk, Inc., San Rafael, CA, USA) to evaluate the bone volume that can be safely harvested. CAD calculations were contrasted to intrasurgical measurements in a subgroup of 20 individuals. CAD calculations yielded a safe harvestable osseous volume of 1.44 cm(3) ± 0.49 for the symphysis and 0.82 cm(3) ± 0.21 for each ramus (p < .0001, confidence interval [CI] 95%: 0.47-0.78). These measurements were significantly lower (p < .0001) than the bone volumes harvested intrasurgically for both symphysis and ramus, respectively (2.40 cm(3) ± 0.50 vs. 2.65 cm(3) ± 0.45). CAD calculations of harvestable symphysis and ramus bone translated into an average of 2.40 cm(3) ± 0.50 (range: 1.80-3.10 cm(3)) and 2.65 cm(3) ± 0.45 (range: 1.90-3.50) of particulate bone graft intrasurgically, respectively. Ramus cortical was significantly thicker than the symphysis cortical, 2.9 ± 0.4 mm versus 2.19 mm ± 0.4 mm (p < .0001, CI 95%: 0.45-1.03). The symphysis and rami are good harvesting sources to obtain dense corticocancellous bone. The significant volumetric CAD differences between the symphysis and ramus seem to balance out intrasurgically and may be due to the greater cortical bone volume at the ramus area. It is plausible to harvest an average of 7.70 cm(3) from the symphysis and rami alone. The use of a CAD software program can enhance surgical treatment planning prior to bone transplantation. © 2012 Wiley Periodicals, Inc.

  3. Computed tomographic colonography to screen for colorectal cancer, extracolonic cancer, and aortic aneurysm: model simulation with cost-effectiveness analysis.

    PubMed

    Hassan, Cesare; Pickhardt, Perry J; Pickhardt, Perry; Laghi, Andrea; Kim, Daniel H; Kim, Daniel; Zullo, Angelo; Iafrate, Franco; Di Giulio, Lorenzo; Morini, Sergio

    2008-04-14

    In addition to detecting colorectal neoplasia, abdominal computed tomography (CT) with colonography technique (CTC) can also detect unsuspected extracolonic cancers and abdominal aortic aneurysms (AAA).The efficacy and cost-effectiveness of this combined abdominal CT screening strategy are unknown. A computerized Markov model was constructed to simulate the occurrence of colorectal neoplasia, extracolonic malignant neoplasm, and AAA in a hypothetical cohort of 100,000 subjects from the United States who were 50 years of age. Simulated screening with CTC, using a 6-mm polyp size threshold for reporting, was compared with a competing model of optical colonoscopy (OC), both without and with abdominal ultrasonography for AAA detection (OC-US strategy). In the simulated population, CTC was the dominant screening strategy, gaining an additional 1458 and 462 life-years compared with the OC and OC-US strategies and being less costly, with a savings of $266 and $449 per person, respectively. The additional gains for CTC were largely due to a decrease in AAA-related deaths, whereas the modeled benefit from extracolonic cancer downstaging was a relatively minor factor. At sensitivity analysis, OC-US became more cost-effective only when the CTC sensitivity for large polyps dropped to 61% or when broad variations of costs were simulated, such as an increase in CTC cost from $814 to $1300 or a decrease in OC cost from $1100 to $500. With the OC-US approach, suboptimal compliance had a strong negative influence on efficacy and cost-effectiveness. The estimated mortality from CT-induced cancer was less than estimated colonoscopy-related mortality (8 vs 22 deaths), both of which were minor compared with the positive benefit from screening. When detection of extracolonic findings such as AAA and extracolonic cancer are considered in addition to colorectal neoplasia in our model simulation, CT colonography is a dominant screening strategy (ie, more clinically effective and more cost-effective) over both colonoscopy and colonoscopy with 1-time ultrasonography.

  4. Computed tomographic findings in 44 dogs and 10 cats with grass seed foreign bodies.

    PubMed

    Vansteenkiste, D P; Lee, K C L; Lamb, C R

    2014-11-01

    To supplement recent reports of computed tomographic (CT) findings in dogs and cats with grass seed foreign bodies. Retrospective review of cases that had CT scan and subsequent retrieval of a grass seed during the same period of hospitalisation from a site included in the scan. Records of 44 dogs and 10 cats were reviewed. Most were presented in the months July to December. Median duration of clinical signs was 4 weeks (range 2 days to 2 years). The most frequent clinical signs were soft tissue swelling (30% cases), coughing (28%), sneezing (28%) and discharge (26%). Grass seeds were retrieved from the thorax (35% cases), nasal cavity (31%), ear (7%), other sites in the head and neck (22%), sublumbar muscles (2%) and pelvic limb (2%). The grass seed was visible in CT images in 10 (19%) cases. Secondary lesions were visible in CT images of 52 (96%) cases, including collection of exudate (37%), abscess (24%), enlarged lymph nodes (22%) and pulmonary consolidation (20%). CT images appeared normal in 4% animals. Grass seeds within the respiratory tract are frequently visible in CT images, but in general CT appears to be more useful for localisation of secondary lesions than as a method of definite diagnosis. © 2014 British Small Animal Veterinary Association.

  5. Spot Sign in Acute Intracerebral Hemorrhage in Dynamic T1-Weighted Magnetic Resonance Imaging.

    PubMed

    Schindlbeck, Katharina A; Santaella, Anna; Galinovic, Ivana; Krause, Thomas; Rocco, Andrea; Nolte, Christian H; Villringer, Kersten; Fiebach, Jochen B

    2016-02-01

    In computed tomographic imaging of acute intracerebral hemorrhage spot sign on computed tomographic angiography has been established as a marker for hematoma expansion and poor clinical outcome. Although, magnetic resonance imaging (MRI) can accurately visualize acute intracerebral hemorrhage, a corresponding MRI marker is lacking to date. We prospectively examined 50 consecutive patients with acute intracerebral hemorrhage within 24 hours of symptom onset. The MRI protocol consisted of a standard stroke protocol and dynamic contrast-enhanced T1-weighted imaging with a time resolution of 7.07 s/batch. Stroke scores were assessed at admission and at time of discharge. Volume measurements of hematoma size and spot sign were performed with MRIcron. Contrast extravasation within sites of the hemorrhage (MRI spot sign) was seen in 46% of the patients. Patients with an MRI spot sign had a significantly shorter time to imaging than those without (P<0.001). The clinical outcome measured by the modified Rankin Scale was significantly worse in patients with spot sign compared with those without (P≤0.001). Hematoma expansion was observed in the spot sign group compared with the nonspot sign group, although the differences were not significant. Spot sign can be detected using MRI on postcontrast T1-weighted and dynamic T1-weighted images. It is associated with worse clinical outcome. The time course of contrast extravasation in dynamic T1 images indicates that these spots represent ongoing bleeding. © 2015 American Heart Association, Inc.

  6. Electrical properties of rat muscle after sciatic nerve injury: Impact on surface impedance measurements assessed via finite element analysis

    NASA Astrophysics Data System (ADS)

    Ahad, M. A.; Rutkove, S. B.

    2010-04-01

    Tetrapolar surface electrical impedance methods are sensitive to changes in muscle status and can therefore provide a means for studying neuromuscular disease noninvasively. In order to better understand the relationship between surface impedance measurements and the actual muscle electrical properties, we performed measurements on 20 adult Wistar rats, 8 of which underwent sciatic nerve crush. Surface impedance measurements were performed on the left hind limb both before injury and out to 2 weeks after injury. In addition, both normal and sciatic crush animals were sacrificed and the dielectric properties of the extracted gastrocnemius muscle measured. We found that 50 kHz conductivities were greater in the animals that underwent crush than in the animals that did not. The permittivities in both directions, however, showed non-significant differences. In order to analyze the effect of these changes as well as the accompanying reduction in muscle volume, a finite element model of the hind limb was developed based on computerized tomographic imaging. The model successfully predicted the surface impedance values in the animals after crush injury and, by its inverse application, may be used to help determine the underlying electrical properties of muscle in various neuromuscular diseases based on surface impedance data.

  7. Finite element method framework for RF-based through-the-wall mapping

    NASA Astrophysics Data System (ADS)

    Campos, Rafael Saraiva; Lovisolo, Lisandro; de Campos, Marcello Luiz R.

    2017-05-01

    Radiofrequency (RF) Through-the-Wall Mapping (TWM) employs techniques originally applied in X-Ray Computerized Tomographic Imaging to map obstacles behind walls. It aims to provide valuable information for rescuing efforts in damaged buildings, as well as for military operations in urban scenarios. This work defines a Finite Element Method (FEM) based framework to allow fast and accurate simulations of the reconstruction of floors blueprints, using Ultra High-Frequency (UHF) signals at three different frequencies (500 MHz, 1 GHz and 2 GHz). To the best of our knowledge, this is the first use of FEM in a TWM scenario. This framework allows quick evaluation of different algorithms without the need to assemble a full test setup, which might not be available due to budgetary and time constraints. Using this, the present work evaluates a collection of reconstruction methods (Filtered Backprojection Reconstruction, Direct Fourier Reconstruction, Algebraic Reconstruction and Simultaneous Iterative Reconstruction) under a parallel-beam acquisition geometry for different spatial sampling rates, number of projections, antenna gains and operational frequencies. The use of multiple frequencies assesses the trade-off between higher resolution at shorter wavelengths and lower through-the-wall penetration. Considering all the drawbacks associated with such a complex problem, a robust and reliable computational setup based on a flexible method such as FEM can be very useful.

  8. Intravenous volume tomographic pulmonary angiography imaging

    NASA Astrophysics Data System (ADS)

    Ning, Ruola; Strang, John G.; Chen, Biao; Conover, David L.; Yu, Rongfeng

    1999-05-01

    This study presents a new intravenous (IV) tomographic angiography imaging technique, called intravenous volume tomographic digital angiography (VTDA) for cross sectional pulmonary angiography. While the advantages of IV-VTDA over spiral CT in terms of volume scanning time and resolution have been validated and reported in our previous papers for head and neck vascular imaging, the superiority of IV-VTDA over spiral CT for cross sectional pulmonary angiography has not been explored yet. The purpose of this study is to demonstrate the advantage of isotropic resolution of IV-VTDA in the x, y and z directions through phantom and animal studies, and to explore its clinical application for detecting clots in pulmonary angiography. A prototype image intensifier-based VTDA imaging system has been designed and constructed by modifying a GE 8800 CT scanner. This system was used for a series of phantom and dog studies. A pulmonary vascular phantom was designed and constructed. The phantom was scanned using the prototype VTDA system for direct 3D reconstruction. Then the same phantom was scanned using a GE CT/i spiral CT scanner using the routine pulmonary CT angiography protocols. IV contrast injection and volume scanning protocols were developed during the dog studies. Both VTDA reconstructed images and spiral CT images of the specially designed phantom were analyzed and compared. The detectability of simulated vessels and clots was assessed as the function of iodine concentration levels, oriented angles, and diameters of the vessels and clots. A set of 3D VTDA reconstruction images of dog pulmonary arteries was obtained with different IV injection rates and isotropic resolution in the x, y and z directions. The results of clot detection studies in dog pulmonary arteries have also been shown. This study presents a new tomographic IV angiography imaging technique for cross sectional pulmonary angiography. The results of phantom and animal studies indicate that IV-VTDA is superior to spiral CT for cross sectional pulmonary angiography.

  9. SU-C-209-07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobson, D; Liu, Y

    2016-06-15

    Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes.more » The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.« less

  10. Associations Between Collateral Status and Thrombus Characteristics and Their Impact in Anterior Circulation Stroke.

    PubMed

    Alves, Heitor C; Treurniet, Kilian M; Dutra, Bruna G; Jansen, Ivo G H; Boers, Anna M M; Santos, Emilie M M; Berkhemer, Olvert A; Dippel, Diederik W J; van der Lugt, Aad; van Zwam, Wim H; van Oostenbrugge, Robert J; Lingsma, Hester F; Roos, Yvo B W E M; Yoo, Albert J; Marquering, Henk A; Majoie, Charles B L M

    2018-02-01

    Thrombus characteristics and collateral score are associated with functional outcome in patients with acute ischemic stroke. It has been suggested that they affect each other. The aim of this study is to evaluate the association between clot burden score, thrombus perviousness, and collateral score and to determine whether collateral score influences the association of thrombus characteristics with functional outcome. Patients with baseline thin-slice noncontrast computed tomography and computed tomographic angiography images from the MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands) were included (n=195). Collateral score and clot burden scores were determined on baseline computed tomographic angiography. Thrombus attenuation increase was determined by comparing thrombus density on noncontrast computed tomography and computed tomographic angiography using a semiautomated method. The association of collateral score with clot burden score and thrombus attenuation increase was evaluated with linear regression. Mediation and effect modification analyses were used to assess the influence of collateral score on the association of clot burden score and thrombus attenuation increase with functional outcome. A higher clot burden score (B=0.063; 95% confidence interval, 0.008-0.118) and a higher thrombus attenuation increase (B=0.014; 95% confidence interval, 0.003-0.026) were associated with higher collateral score. Collateral score mediated the association of clot burden score with functional outcome. The association between thrombus attenuation increase and functional outcome was modified by the collateral score, and this association was stronger in patients with moderate and good collaterals. Patients with lower thrombus burden and higher thrombus perviousness scores had higher collateral score. The positive effect of thrombus perviousness on clinical outcome was only present in patients with moderate and high collateral scores. URL: http://www.trialregister.nl. Unique identifier: NTR1804 and URL: http://www.controlled-trials.com Unique identifier: ISRCTN10888758. © 2018 The Authors.

  11. Clinical coherent anti-Stokes Raman scattering and multiphoton tomography of human skin with a femtosecond laser and photonic crystal fiber

    NASA Astrophysics Data System (ADS)

    Breunig, Hans Georg; Weinigel, Martin; Bückle, Rainer; Kellner-Höfer, Marcel; Lademann, Jürgen; Darvin, Maxim E.; Sterry, Wolfram; König, Karsten

    2013-02-01

    We report on in vivo coherent anti-Stokes Raman scattering spectroscopy (CARS), two-photon fluorescence and second-harmonic-generation imaging on human skin with a novel multimodal clinical CARS/multiphoton tomograph. CARS imaging is realized by a combination of femtosecond pulses with broadband continuum pulses generated by a photonic crystal fiber. The images reveal the microscopic distribution of (i) non-fluorescent lipids, (ii) endogenous fluorophores and (iii) the collagen network inside the human skin in vivo with subcellular resolution. Examples of healthy as well as cancer-affected skin are presented.

  12. Intravascular lymphomatosis presenting as acute hemispheric dysfunction.

    PubMed

    Hwang, Woo Sub; Jung, Chul Won; Ko, Young Hye; Seo, Sang Won; Na, Duk L

    2012-11-01

    Intravascular lymphomatosis (IVL) is known to affect both hemispheres of the brain and manifests clinically as seizures or dementia. To our knowledge, there have been no cases in which acute hemispheric dysfunction is manifested in IVL. We present a 54-year-old man who showed steroid responsive acute hemispheric dysfunction. A technetium 99m-ethyl cysteinate dimer single-photon emission computed tomographic scan of the brain revealed hypoperfusion in the right hemisphere. The bone marrow biopsy specimen confirmed malignant lymphoid cells in vessels, which suggested IVL. Our case signifies the diversity of clinical manifestations in IVL. Copyright © 2012. Published by Elsevier Inc.

  13. IMPORTANCE OF THE DETERMINATION OF THE WEIGHT OF THE THYROID GLAND AND THE CLINICAL BIOLOGICAL FACTORS IN THE TREATMENT OF HYPERTHYRODISM WITH $sup 131$I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clode, W.; Sobral, V.; Baptista, A.M.

    1959-10-31

    Clinical results are reviewed for a group of 117 patients treated for hyperthyroidism with iodine-131. The importance of clinical, biological, and physical factors on results is stressed. Various methods for determining thyroid mass are discussed. A visualization technique, called pneumothyroid, is described in which the thyroid volume is determined from a series of x rays and tomographs following the injection of air into the tissue surrounding the thyroid capsule. The apparatus used resembles that used in pneumothorax. This method was found superior to palpation for estimations of thyroid weight prior to calculation of iodine-131 dose. (C.H.)

  14. Physics and engineering aspects of cell and tissue imaging systems: microscopic devices and computer assisted diagnosis.

    PubMed

    Chen, Xiaodong; Ren, Liqiang; Zheng, Bin; Liu, Hong

    2013-01-01

    The conventional optical microscopes have been used widely in scientific research and in clinical practice. The modern digital microscopic devices combine the power of optical imaging and computerized analysis, archiving and communication techniques. It has a great potential in pathological examinations for improving the efficiency and accuracy of clinical diagnosis. This chapter reviews the basic optical principles of conventional microscopes, fluorescence microscopes and electron microscopes. The recent developments and future clinical applications of advanced digital microscopic imaging methods and computer assisted diagnosis schemes are also discussed.

  15. Computerized counseling reduces HIV-1 viral load and sexual transmission risk: findings from a randomized controlled trial.

    PubMed

    Kurth, Ann E; Spielberg, Freya; Cleland, Charles M; Lambdin, Barrot; Bangsberg, David R; Frick, Pamela A; Severynen, Anneleen O; Clausen, Marc; Norman, Robert G; Lockhart, David; Simoni, Jane M; Holmes, King K

    2014-04-15

    Evaluate a computerized intervention supporting antiretroviral therapy (ART) adherence and HIV transmission prevention. Longitudinal randomized controlled trial. An academic HIV clinic and a community-based organization in Seattle. In a total of 240 HIV-positive adults on ART, 209 completed 9-month follow-up (87% retention). Randomization to computerized counseling or assessment only, 4 sessions over 9 months. HIV-1 viral suppression, and self-reported ART adherence and transmission risks, compared using generalized estimating equations. Overall, intervention participants had reduced viral load: mean 0.17 log10 decline, versus 0.13 increase in controls, P = 0.053, and significant difference in ART adherence baseline to 9 months (P = 0.046). Their sexual transmission risk behaviors decreased (odds ratio = 0.55, P = 0.020), a reduction not seen among controls (odds ratio = 1.1, P = 0.664), and a significant difference in change (P = 0.040). Intervention effect was driven by those most in need; among those with detectable virus at baseline (>30 copies/mL, n = 89), intervention effect was mean 0.60 log10 viral load decline versus 0.15 increase in controls, P = 0.034. ART adherence at the final follow-up was 13 points higher among intervention participants versus controls, P = 0.038. Computerized counseling is promising for integrated ART adherence and safer sex, especially for individuals with problems in these areas. This is the first intervention to report improved ART adherence, viral suppression, and reduced secondary sexual transmission risk behavior.

  16. Dental computed tomographic imaging as age estimation: morphological analysis of the third molar of a group of Turkish population.

    PubMed

    Cantekin, Kenan; Sekerci, Ahmet Ercan; Buyuk, Suleyman Kutalmis

    2013-12-01

    Computed tomography (CT) is capable of providing accurate and measurable 3-dimensional images of the third molar. The aims of this study were to analyze the development of the mandibular third molar and its relation to chronological age and to create new reference data for a group of Turkish participants aged 9 to 25 years on the basis of cone-beam CT images. All data were obtained from the patients' records including medical, social, and dental anamnesis and cone-beam CT images of 752 patients. Linear regression analysis was performed to obtain regression formulas for dental age calculation with chronological age and to determine the coefficient of determination (r) for each sex. Statistical analysis showed a strong correlation between age and third-molar development for the males (r2 = 0.80) and the females (r2 = 0.78). Computed tomographic images are clinically useful for accurate and reliable estimation of dental ages of children and youth.

  17. Multislice coronary computed tomographic angiography in emergency department presentations of unsuspected acute myocardial infarction.

    PubMed

    Hecht, Harvey S; Bhatti, Tandeep

    2009-01-01

    Coronary computed tomographic angiography (CCTA) is not indicated in the setting of acute myocardial infarction in the emergency department (ED). Nonetheless, acute coronary syndromes may have atypical presentations, and CCTA may be inadvertently performed in this setting. This study was designed to determine the frequency and characteristics of CCTA imaging of unsuspected acute myocardial infarction in the ED. All CCTAs performed in the ED at Lenox Hill Hospital were reviewed for clinical indications and subsequent course; patients with documented acute myocardial infarction were identified. Of the 500 CCTAs performed on ED patients in the Lenox Hill laboratory, 5 patients (1%) were imaged during the initial phase of an unsuspected acute myocardial infarction; in all cases the CCTAs were key to the diagnosis. The imaging characteristics were (1) total or subtotal occlusion and (2) transmural hypodensity in the infarct area. Although acute myocardial infarction on CCTA in ED patients is an infrequent event, proper and prompt recognition is critical for appropriate patient care, particularly as applications to the ED increase.

  18. The medical simulation markup language - simplifying the biomechanical modeling workflow.

    PubMed

    Suwelack, Stefan; Stoll, Markus; Schalck, Sebastian; Schoch, Nicolai; Dillmann, Rüdiger; Bendl, Rolf; Heuveline, Vincent; Speidel, Stefanie

    2014-01-01

    Modeling and simulation of the human body by means of continuum mechanics has become an important tool in diagnostics, computer-assisted interventions and training. This modeling approach seeks to construct patient-specific biomechanical models from tomographic data. Usually many different tools such as segmentation and meshing algorithms are involved in this workflow. In this paper we present a generalized and flexible description for biomechanical models. The unique feature of the new modeling language is that it not only describes the final biomechanical simulation, but also the workflow how the biomechanical model is constructed from tomographic data. In this way, the MSML can act as a middleware between all tools used in the modeling pipeline. The MSML thus greatly facilitates the prototyping of medical simulation workflows for clinical and research purposes. In this paper, we not only detail the XML-based modeling scheme, but also present a concrete implementation. Different examples highlight the flexibility, robustness and ease-of-use of the approach.

  19. Quantitative multiphoton imaging

    NASA Astrophysics Data System (ADS)

    König, Karsten; Weinigel, Martin; Breunig, Hans Georg; Uchugonova, Aisada

    2014-02-01

    Certified clinical multiphoton tomographs for label-free multidimensional high-resolution in vivo imaging have been introduced to the market several years ago. Novel tomographs include a flexible 360° scan head attached to a mechanooptical arm for autofluorescence and SHG imaging as well as a CARS module. Non-fluorescent lipids and water, mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen can be imaged in vivo with submicron resolution in human skin. Sensitive and rapid detectors allow single photon counting and the construction of 3D maps where the number of detected photons per voxel is depicted. Intratissue concentration profiles from endogenous as well exogenous substances can be generated when the number of detected photons can be correlated with the number of molecules with respect to binding and scattering behavior. Furthermore, the skin ageing index SAAID based on the ratio elastin/collagen as well as the epidermis depth based on the onset of SHG generation can be determined.

  20. A method of measuring anterior chamber volume using the anterior segment optical coherence tomographer and specialized software.

    PubMed

    Wang, Ningli; Wang, Bingsong; Zhai, Gaoshou; Lei, Kun; Wang, Lan; Congdon, Nathan

    2007-05-01

    To describe and evaluate a new method for measuring anterior chamber volume (ACV). Observational case series. The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups. Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes. The ACV values obtained by this method were repeatable and in accord with clinical observation.

  1. Chamber dimensions and functional assessment with coronary computed tomographic angiography as compared to echocardiography using American Society of Echocardiography guidelines

    PubMed Central

    Rose, Michael; Rubal, Bernard; Hulten, Edward; Slim, Jennifer N; Steel, Kevin; Furgerson, James L; Villines, Todd C

    2014-01-01

    Background: The correlation between normal cardiac chamber linear dimensions measured during retrospective coronary computed tomographic angiography as compared to transthoracic echocardiography using the American Society of Echocardiography guidelines is not well established. Methods: We performed a review from January 2005 to July 2011 to identify subjects with retrospective electrocardiogram-gated coronary computed tomographic angiography scans for chest pain and transthoracic echocardiography with normal cardiac structures performed within 90 days. Dimensions were manually calculated in both imaging modalities in accordance with the American Society of Echocardiography published guidelines. Left ventricular ejection fraction was calculated on echocardiography manually using the Simpson’s formula and by coronary computed tomographic angiography using the end-systolic and end-diastolic volumes. Results: We reviewed 532 studies, rejected 412 and had 120 cases for review with a median time between studies of 7 days (interquartile range (IQR25,75) = 0–22 days) with no correlation between the measurements made by coronary computed tomographic angiography and transthoracic echocardiography using Bland–Altman analysis. We generated coronary computed tomographic angiography cardiac dimension reference ranges for both genders for our population. Conclusion: Our findings represent a step towards generating cardiac chamber dimensions’ reference ranges for coronary computed tomographic angiography as compared to transthoracic echocardiography in patients with normal cardiac morphology and function using the American Society of Echocardiography guideline measurements that are commonly used by cardiologists. PMID:26770706

  2. Enrollment into a time sensitive clinical study in the critical care setting: results from computerized septic shock sniffer implementation.

    PubMed

    Herasevich, Vitaly; Pieper, Matthew S; Pulido, Juan; Gajic, Ognjen

    2011-01-01

    Recruitment of patients into time sensitive clinical trials in intensive care units (ICU) poses a significant challenge. Enrollment is limited by delayed recognition and late notification of research personnel. The objective of the present study was to evaluate the effectiveness of the implementation of electronic screening (septic shock sniffer) regarding enrollment into a time sensitive (24 h after onset) clinical study of echocardiography in severe sepsis and septic shock. We developed and tested a near-real time computerized alert system, the septic shock sniffer, based on established severe sepsis/septic shock diagnostic criteria. A sniffer scanned patients' data in the electronic medical records and notified the research coordinator on call through an institutional paging system of potentially eligible patients. The performance of the septic shock sniffer was assessed. The septic shock sniffer performed well with a positive predictive value of 34%. Electronic screening doubled enrollment, with 68 of 4460 ICU admissions enrolled during the 9 months after implementation versus 37 of 4149 ICU admissions before sniffer implementation (p<0.05). Efficiency was limited by study coordinator availability (not available at nights or weekends). Automated electronic medical records screening improves the efficiency of enrollment and should be a routine tool for the recruitment of patients into time sensitive clinical trials in the ICU setting.

  3. Enrollment into a time sensitive clinical study in the critical care setting: results from computerized septic shock sniffer implementation

    PubMed Central

    Pieper, Matthew S; Pulido, Juan; Gajic, Ognjen

    2011-01-01

    Objective Recruitment of patients into time sensitive clinical trials in intensive care units (ICU) poses a significant challenge. Enrollment is limited by delayed recognition and late notification of research personnel. The objective of the present study was to evaluate the effectiveness of the implementation of electronic screening (septic shock sniffer) regarding enrollment into a time sensitive (24 h after onset) clinical study of echocardiography in severe sepsis and septic shock. Design We developed and tested a near-real time computerized alert system, the septic shock sniffer, based on established severe sepsis/septic shock diagnostic criteria. A sniffer scanned patients' data in the electronic medical records and notified the research coordinator on call through an institutional paging system of potentially eligible patients. Measurement The performance of the septic shock sniffer was assessed. Results The septic shock sniffer performed well with a positive predictive value of 34%. Electronic screening doubled enrollment, with 68 of 4460 ICU admissions enrolled during the 9 months after implementation versus 37 of 4149 ICU admissions before sniffer implementation (p<0.05). Efficiency was limited by study coordinator availability (not available at nights or weekends). Conclusions Automated electronic medical records screening improves the efficiency of enrollment and should be a routine tool for the recruitment of patients into time sensitive clinical trials in the ICU setting. PMID:21508415

  4. Recommended practices for computerized clinical decision support and knowledge management in community settings: a qualitative study

    PubMed Central

    2012-01-01

    Background The purpose of this study was to identify recommended practices for computerized clinical decision support (CDS) development and implementation and for knowledge management (KM) processes in ambulatory clinics and community hospitals using commercial or locally developed systems in the U.S. Methods Guided by the Multiple Perspectives Framework, the authors conducted ethnographic field studies at two community hospitals and five ambulatory clinic organizations across the U.S. Using a Rapid Assessment Process, a multidisciplinary research team: gathered preliminary assessment data; conducted on-site interviews, observations, and field surveys; analyzed data using both template and grounded methods; and developed universal themes. A panel of experts produced recommended practices. Results The team identified ten themes related to CDS and KM. These include: 1) workflow; 2) knowledge management; 3) data as a foundation for CDS; 4) user computer interaction; 5) measurement and metrics; 6) governance; 7) translation for collaboration; 8) the meaning of CDS; 9) roles of special, essential people; and 10) communication, training, and support. Experts developed recommendations about each theme. The original Multiple Perspectives framework was modified to make explicit a new theoretical construct, that of Translational Interaction. Conclusions These ten themes represent areas that need attention if a clinic or community hospital plans to implement and successfully utilize CDS. In addition, they have implications for workforce education, research, and national-level policy development. The Translational Interaction construct could guide future applied informatics research endeavors. PMID:22333210

  5. The implementation of computerized cognitive behavioural therapies in a service user-led, third sector self help clinic.

    PubMed

    Cavanagh, Kate; Seccombe, Nick; Lidbetter, Nicky

    2011-07-01

    The efficacy and effectiveness of a computerized cognitive behavioural therapy (CCBT) package, Beating the Blues, has been demonstrated in a large randomized controlled trial and several pragmatic studies in the National Health Service (NHS). The current study tests the generalizability of this finding to the implementation of CCBT in a service user-led, third sector Self Help Clinic. 510 referrals for the Beating the Blues program were received over a 16 month period in routine care. The Patient Health Questionnaire Depression (PHQ-9) and Anxiety (GAD-7) Scales were administered pre-treatment and during each treatment session. The 10-item Clinical Outcomes in Routine Evaluation-Outcome Measure (CORE-OM), Work and Social Adjustment Scale and Patient Experience Questionnaire were also administered pre-treatment and immediately on completing treatment. More than two-thirds of referrals were suitable for treatment and completed a baseline assessment; 84% of these started the Beating the Blues program. Two-hundred and twenty-six people meeting caseness criteria at baseline completed at least two sessions of CCBT. Of these, 50% met recovery criteria at their final point of measurement. Completer and intention-to-treat analysis also demonstrated statistically and clinically significant improvements on key outcome measures. CCBT can be effectively implemented in a service user-led, third sector Self Help Clinic, increasing access to psychological therapies to meet local needs for tier two interventions for depression and anxiety.

  6. Feasibility and acceptability of a computer-based tool to improve contraceptive counseling.

    PubMed

    Wilson, Ellen K; Krieger, Kathleen E; Koo, Helen P; Minnis, Alexandra M; Treiman, Katherine

    2014-07-01

    The objective was to test the feasibility and acceptability of a computerized tool, Smart Choices, designed to enhance the quality of contraceptive counseling in family planning clinics. The tool includes (a) a questionnaire completed by patients and summarized in a printout for providers and (b) a birth control guide patients explore to learn about various contraceptive methods. In 2 family planning clinics, we conducted interviews with 125 women who used the Smart Choices computerized tool and 7 providers. Smart Choices integrated into clinic flow well in one clinic, but less well in the other, which had very short waiting times. Patients were generally enthusiastic about Smart Choices, including its helpfulness in preparing them and their providers for the counseling session and increasing their knowledge of contraceptive methods. Providers varied in how much they used the printout and in their opinions about its usefulness. Some felt its usefulness was limited because it overlapped with the clinic's intake forms or because it did not match with their concept of counseling needs. Others felt it provided valuable information not collected by intake forms and more honest information. Some found Smart Choices to be most helpful with patients who were unsure what method they wanted. Smart Choices is feasible to implement and well received by patients, but modifications are needed to increase provider enthusiasm for this tool. The Smart Choices tool requires refinement before widespread dissemination. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Validity of a computerized population registry of dementia based on clinical databases.

    PubMed

    Mar, J; Arrospide, A; Soto-Gordoa, M; Machón, M; Iruin, Á; Martinez-Lage, P; Gabilondo, A; Moreno-Izco, F; Gabilondo, A; Arriola, L

    2018-05-08

    The handling of information through digital media allows innovative approaches for identifying cases of dementia through computerized searches within the clinical databases that include systems for coding diagnoses. The aim of this study was to analyze the validity of a dementia registry in Gipuzkoa based on the administrative and clinical databases existing in the Basque Health Service. This is a descriptive study based on the evaluation of available data sources. First, through review of medical records, the diagnostic validity was evaluated in 2 samples of cases identified and not identified as dementia. The sensitivity, specificity and positive and negative predictive value of the diagnosis of dementia were measured. Subsequently, the cases of living dementia in December 31, 2016 were searched in the entire Gipuzkoa population to collect sociodemographic and clinical variables. The validation samples included 986 cases and 327 no cases. The calculated sensitivity was 80.2% and the specificity was 99.9%. The negative predictive value was 99.4% and positive value was 95.1%. The cases in Gipuzkoa were 10,551, representing 65% of the cases predicted according to the literature. Antipsychotic medication were taken by a 40% and a 25% of the cases were institutionalized. A registry of dementias based on clinical and administrative databases is valid and feasible. Its main contribution is to show the dimension of dementia in the health system. Copyright © 2018 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. A Retrospective Tomographic and Histologic Analysis of Horizontal Bone Augmentation in Maxillary Atrophic Ridges Using Resorbable Membrane with Anorganic Bovine Bone-Derived Mineral and Plasma Rich in Growth Factors.

    PubMed

    Lorenzetti, Massimo; Vono, Maurizio; Lorenzetti, Virginia

    2018-02-16

    A total of six patients treated from 2010 to 2014, having a knife-edge ridge (Cawood-Howell Class IV resorbed ridges) and requiring an implant-prosthetic rehabilitation, were selected. Tomographic measurement of the edentulous ridges was performed before grafting and after implant placement. At 6 months postgraft, a total of 41 implants had been inserted, 17 in the posterior region, 12 in the central region, and 12 in the anterior region. No surgical or healing complications were recorded, and the prostheses were loaded 6 to 9 months after implant placement. The tomographic measurements demonstrated an increased area in all the sites where bone augmentation had been performed, corresponding to 11.1% in the anterior region, 94.7% in the central region, and 760.2% in the posterior region. Histology was performed in 2 patients, one at 1 year and the other at 5 years postgrafting, and demonstrated the presence of mature lamellar bone tissue and newly formed bone without morphologic signs of necrosis or inflammation and a reduction of 50% to 30% of the grafted material. Although this study included a small number of clinical cases, it demonstrated how management of the atrophic maxillary ridge, with the goal of implant placement, may be handled using a technique that requires a single anorganic bovine bone-derived mineral treatment combined with a plasma rich in growth factors and resorbable collagen membrane.

  9. Computed Tomography Angiography in Microsurgery: Indications, Clinical Utility, and Pitfalls

    PubMed Central

    Lee, Gordon K.; Fox, Paige M.; Riboh, Jonathan; Hsu, Charles; Saber, Sepideh; Rubin, Geoffrey D.; Chang, James

    2013-01-01

    Objective: Computed tomographic angiography (CTA) can be used to obtain 3-dimensional vascular images and soft-tissue definition. The goal of this study was to evaluate the reliability, usefulness, and pitfalls of CTA in preoperative planning of microvascular reconstructive surgery. Methods: A retrospective review of patients who obtained preoperative CTA in preparation for planned microvascular reconstruction was performed over a 5-year period (2001–2005). The influence of CTA on the original operative plan was assessed for each patient, and CTA results were correlated to the operative findings. Results: Computed tomographic angiography was performed on 94 patients in preparation for microvascular reconstruction. In 48 patients (51%), vascular abnormalities were noted on CTA. Intraoperative findings correlated with CTA results in 97% of cases. In 42 patients (45%), abnormal CTA findings influenced the original operative plan, such as the choice of vessels, side of harvest, or nature of the reconstruction (local flap instead of free tissue transfer). Technical difficulties in performing CTA were encountered in 5 patients (5%) in whom interference from external fixation devices was the main cause. Conclusions: This large study of CTA obtained for preoperative planning of reconstructive microsurgery at both donor and recipient sites study demonstrates that CTA is safe and highly accurate. Computed tomographic angiography can alter the surgeon's reconstructive plan when abnormalities are noted preoperatively and consequently improve results by decreasing vascular complication rates. The use of CTA should be considered for cases of microsurgical reconstruction where the vascular anatomy may be questionable. PMID:24023972

  10. Computerized content analysis of some adolescent writings of Napoleon Bonaparte: a test of the validity of the method.

    PubMed

    Gottschalk, Louis A; DeFrancisco, Don; Bechtel, Robert J

    2002-08-01

    The aim of this study was to test the validity of a computer software program previously demonstrated to be capable of making DSM-IV neuropsychiatric diagnoses from the content analysis of speech or verbal texts. In this report, the computer program was applied to three personal writings of Napoleon Bonaparte when he was 12 to 16 years of age. The accuracy of the neuropsychiatric evaluations derived from the computerized content analysis of these writings of Napoleon was independently corroborated by two biographers who have described pertinent details concerning his life situations, moods, and other emotional reactions during this adolescent period of his life. The relevance of this type of computer technology to psychohistorical research and clinical psychiatry is suggested.

  11. Worldwide distribution of Waardenburg syndrome.

    PubMed

    Nayak, Chetan S; Isaacson, Glenn

    2003-09-01

    To clarify the multiracial occurrence of Waardenburg syndrome, we present a case series and literature review. A computerized review of the English-language literature was conducted to assess the distribution of reported occurrences of Waardenburg syndrome in populations around the world. We detail the clinical features of 2 family cohorts: one of Western European origin and the other from South Asia. A computerized literature review found sporadic cases of the syndrome in many ethnic groups, including Japanese, Taiwanese, and Middle Eastern families. The highest reported incidence is among Kenyan Africans. Waardenburg syndrome accounts for between 2% and 5% of cases of congenital deafness. It was first described in Northern European cohorts and is widely identified in fair-skinned populations. We hope to raise awareness of the worldwide distribution of this important cause of hearing loss.

  12. Visualization techniques for tongue analysis in traditional Chinese medicine

    NASA Astrophysics Data System (ADS)

    Pham, Binh L.; Cai, Yang

    2004-05-01

    Visual inspection of the tongue has been an important diagnostic method of Traditional Chinese Medicine (TCM). Clinic data have shown significant connections between various viscera cancers and abnormalities in the tongue and the tongue coating. Visual inspection of the tongue is simple and inexpensive, but the current practice in TCM is mainly experience-based and the quality of the visual inspection varies between individuals. The computerized inspection method provides quantitative models to evaluate color, texture and surface features on the tongue. In this paper, we investigate visualization techniques and processes to allow interactive data analysis with the aim to merge computerized measurements with human expert's diagnostic variables based on five-scale diagnostic conditions: Healthy (H), History Cancers (HC), History of Polyps (HP), Polyps (P) and Colon Cancer (C).

  13. Regulation, Privacy and Security: Chairman's Opening Remarks

    PubMed Central

    Gabrieli, E.R.

    1979-01-01

    Medical privacy is a keystone of a free democratic society. To conserve the right of the patient to medical privacy, computerization of the medical data must be regulated. This paper enumerates some steps to be taken urgently for the protection of computerized sensitive medical data. A computer-oriented medical lexicon is urgently needed for accurate coding. Health industry standards should be drafted. The goals of various data centers must be sharply defined to avoid conflicts of interest. Medical privacy should be studied further, and medical data centers should consider cost-effectiveness. State boards for medical privacy should be created to monitor data security procedures. There is a need for purposeful decentralization. A national medical information policy should be drafted, and a national clinical information board should implement the nation's medical information policy.

  14. Congruence of Self-Reported Medications with Pharmacy Prescription Records in Low-Income Older Adults

    ERIC Educational Resources Information Center

    Caskie, Grace I. L.; Willis, Sherry L.

    2004-01-01

    Purpose: This study examined the congruence of self-reported medications with computerized pharmacy records. Design and Methods: Pharmacy records and self-reported medications were obtained for 294 members of a state pharmaceutical assistance program who also participated in ACTIVE, a clinical trial on cognitive training in nondemented elderly…

  15. Internet-Based Cervical Cancer Screening Program

    DTIC Science & Technology

    2008-05-01

    information technology have facilitated the Internet transmission and archival storage of digital images and other clinical information . The combination of...Phase included: 1) development of hardware, software, and interfaces between computerized scanning device and Internet - linked servers and reading...AD_________________ Award Number: W81XWH-04-C-0083 TITLE: Internet -Based Cervical Cancer Screening

  16. Eleven Years of Primary Health Care Delivery in an Academic Nursing Center.

    ERIC Educational Resources Information Center

    Hildebrandt, Eugenie; Baisch, Mary Jo; Lundeen, Sally P.; Bell-Calvin, Jean; Kelber, Sheryl

    2003-01-01

    Client visits to an academic community nursing center (n=25,495) were coded and analyzed. Results show expansion of nursing practice and services, strong case management, and management of illness care. The usefulness of computerized clinical documentation system and of the Lundeen conceptional model of community nursing care was demonstrated.…

  17. Positron emission tomography/computerized tomography in lung cancer

    PubMed Central

    Vural, Gulin Ucmak

    2014-01-01

    Positron emission tomography (PET) using 2-(18F)-flouro-2-deoxy-D-glucose (FDG) has emerged as a useful tool in the clinical work-up of lung cancer. This review article provides an overview of applications of PET in diagnosis, staging, treatment response evaluation, radiotherapy planning, recurrence assessment and prognostication of lung cancer. PMID:24914421

  18. ATS-PD: An Adaptive Testing System for Psychological Disorders

    ERIC Educational Resources Information Center

    Donadello, Ivan; Spoto, Andrea; Sambo, Francesco; Badaloni, Silvana; Granziol, Umberto; Vidotto, Giulio

    2017-01-01

    The clinical assessment of mental disorders can be a time-consuming and error-prone procedure, consisting of a sequence of diagnostic hypothesis formulation and testing aimed at restricting the set of plausible diagnoses for the patient. In this article, we propose a novel computerized system for the adaptive testing of psychological disorders.…

  19. PubMed Central

    FOUNTOULAKIS, E.N.; PAPADAKI, E.; PANAGIOTAKI, I.; GIANNIKAKI, E.; LAGOUDIANAKIS, G.; BIZAKIS, J.

    2011-01-01

    SUMMARY Haemangiopericytoma is a rare soft tissue tumour, with great histological variability and unpredictable clinical and biological behaviour. The precise cell type origin is uncertain. One third of haemangiopericytomas occur in the head and neck area, but only a few cases have been reported regarding localization at the parapharyngeal space. Herewith, case is presented of a 54-year-old female, referred to our Department due to a parapharyngeal space tumour with non-specific imaging characteristics. The patient underwent radical excision of the tumour with a trans-cervical sub-mandibular approach. The histolopathologic examination revealed a neoplasm with the characteristic features of haemangiopericytoma. One year later, during the scheduled follow-up, the computerized tomography scan showed no evidence of recurrence or residual disease. The pre-operative evaluation of a haemangiopericytoma must include a thorough imaging evaluation with computerized tomography and magnetic resonance imaging, even if results may not be specific for haemangiopericytoma. Angiography and pre-operative embolization may be performed in cases of large tumours with significant vascularity. The treatment of choice is radical excision. The follow-up includes clinical evaluation every 6 months and annual magnetic resonance imaging for at least 3 years. PMID:22058597

  20. A framework for capturing clinical data sets from computerized sources.

    PubMed

    McDonald, C J; Overhage, J M; Dexter, P; Takesue, B Y; Dwyer, D M

    1997-10-15

    The pressure to improve health care and provide better care at a lower cost has generated the need for efficient capture of clinical data. Many data sets are now being defined to analyze health care. Historically, review and research organizations have simply determined what data they wanted to collect, developed forms, and then gathered the information through chart review without regard to what is already available institutionally in computerized databases. Today, much electronic patient information is available in operational data systems (for example, laboratory systems, pharmacy systems, and surgical scheduling systems) and is accessible by agencies and organizations through standards for messages, codes, and encrypted electronic mail. Such agencies and organizations should define the elements of their data sets in terms of standardized operational data, and data producers should fully adopt these code and message standards. The Health Plan Employer Data and Information Set and the Council of State and Territorial Epidemiologists in collaboration with the Centers for Disease Control and Prevention and the Association of State and Territorial Public Health Laboratory Directors provide examples of how this can be done.

  1. Implementation of real-time digital endoscopic image processing system

    NASA Astrophysics Data System (ADS)

    Song, Chul Gyu; Lee, Young Mook; Lee, Sang Min; Kim, Won Ky; Lee, Jae Ho; Lee, Myoung Ho

    1997-10-01

    Endoscopy has become a crucial diagnostic and therapeutic procedure in clinical areas. Over the past four years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholecystectomy, pelviscopic endometriosis, and surgical arthroscopy. In this study, we developed a computer system, which is composed of a frame grabber, a sound board, a VCR control board, a LAN card and EDMS. Also, computer system controls peripheral instruments such as a color video printer, a video cassette recorder, and endoscopic input/output signals. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards; namely Microsoft Windows as an operating system, TCP/IP as a network protocol and a time sequential database that handles both images and speech. For the purpose of data storage, we used MOD and CD- R. Digital endoscopic system was designed to be able to store, recreate, change, and compress signals and medical images. Computerized endoscopy enables us to generate and manipulate the original visual document, making it accessible to a virtually unlimited number of physicians.

  2. Methodological, technical, and ethical issues of a computerized data system.

    PubMed

    Rice, C A; Godkin, M A; Catlin, R J

    1980-06-01

    This report examines some methodological, technical, and ethical issues which need to be addressed in designing and implementing a valid and reliable computerized clinical data base. The report focuses on the data collection system used by four residency based family health centers, affiliated with the University of Massachusetts Medical Center. It is suggested that data reliability and validity can be maximized by: (1) standardizing encounter forms at affiliated health centers to eliminate recording biases and ensure data comparability; (2) using forms with a diagnosis checklist to reduce coding errors and increase the number of diagnoses recorded per encounter; (3) developing uniform diagnostic criteria; (4) identifying sources of error, including discrepancies of clinical data as recorded in medical records, encounter forms, and the computer; and (5) improving provider cooperation in recording data by distributing data summaries which reinforce the data's applicability to service provision. Potential applications of the data for research purposes are restricted by personnel and computer costs, confidentiality considerations, programming related issues, and, most importantly, health center priorities, largely focused on patient care, not research.

  3. Embedding measurement within existing computerized data systems: scaling clinical laboratory and medical records heart failure data to predict ICU admission.

    PubMed

    Fisher, William P; Burton, Elizabeth C

    2010-01-01

    This study employs existing data sources to develop a new measure of intensive care unit (ICU) admission risk for heart failure patients. Outcome measures were constructed from laboratory, accounting, and medical record data for 973 adult inpatients with primary or secondary heart failure. Several scoring interpretations of the laboratory indicators were evaluated relative to their measurement and predictive properties. Cases were restricted to tests within first lab draw that included at least 15 indicators. After optimizing the original clinical observations, a satisfactory heart failure severity scale was calibrated on a 0-1000 continuum. Patients with unadjusted CHF severity measures of 550 or less were 2.7 times more likely to be admitted to the ICU than those with higher measures. Patients with low HF severity measures (550 or less) adjusted for demographic and diagnostic risk factors are about six times more likely to be admitted to the ICU than those with higher adjusted measures. A nomogram facilitates routine clinical application. Existing computerized data systems could be programmed to automatically structure clinical laboratory reports using the results of studies like this one to reduce data volume with no loss of information, make laboratory results more meaningful to clinical end users, improve the quality of care, reduce errors and unneeded tests, prevent unnecessary ICU admissions, lower costs, and improve patient satisfaction. Existing data typically examined piecemeal form a coherent scale measuring heart failure severity sensitive to increased likelihood of ICU admission. Marked improvements in ROC curves were found for the aggregate measures relative to individual clinical indicators.

  4. Impact of clinical presentation and pretest likelihood on the relation between calcium score and computed tomographic coronary angiography.

    PubMed

    van Werkhoven, Jacob M; de Boer, Stephanie M; Schuijf, Joanne D; Cademartiri, Filippo; Maffei, Erica; Jukema, J Wouter; Boogers, Mark J; Kroft, Lucia J; de Roos, Albert; Bax, Jeroen J

    2010-12-15

    The purpose of the present study was to assess the impact of clinical presentation and pretest likelihood on the relation between coronary calcium score (CCS) and computed tomographic coronary angiography (CTA) to determine the role of CCS as a gatekeeper to CTA in patients presenting with chest pain. In 576 patients with suspected coronary artery disease (CAD), CCS and CTA were performed. CCS was categorized as 0, 1 to 400, and >400. On CT angiogram the presence of significant CAD (≥50% luminal narrowing) was determined. Significant CAD was observed in 14 of 242 patients (5.8%) with CCS 0, in 94 of 260 patients (36.2%) with CCS 1 to 400, and in 60 of 74 patients (81.1%) with CCS >400. In patients with CCS 0, prevalence of significant CAD increased from 3.9% to 4.1% and 14.3% in nonanginal, atypical, and typical chest pain, respectively, and from 3.4% to 3.9% and 27.3% with a low, intermediate, and high pretest likelihood, respectively. In patients with CCS 1 to 400, prevalence of significant CAD increased from 27.4% to 34.7% and 51.7% in nonanginal, atypical, and typical chest pain, respectively, and from 15.4% to 35.6% and 50% in low, intermediate, and high pretest likelihood, respectively. In patients with CCS >400, prevalence of significant CAD on CT angiogram remained high (>72%) regardless of clinical presentation and pretest likelihood. In conclusion, the relation between CCS and CTA is influenced by clinical presentation and pretest likelihood. These factors should be taken into account when using CCS as a gatekeeper for CTA. Copyright © 2010 Elsevier Inc. All rights reserved.

  5. Costs and clinical outcomes in individuals without known coronary artery disease undergoing coronary computed tomographic angiography from an analysis of Medicare category III transaction codes.

    PubMed

    Min, James K; Shaw, Leslee J; Berman, Daniel S; Gilmore, Amanda; Kang, Ning

    2008-09-15

    Multidetector coronary computed tomographic angiography (CCTA) demonstrates high accuracy for the detection and exclusion of coronary artery disease (CAD) and predicts adverse prognosis. To date, opportunity costs relating the clinical and economic outcomes of CCTA compared with other methods of diagnosing CAD, such as myocardial perfusion single-photon emission computed tomography (SPECT), remain unknown. An observational, multicenter, patient-level analysis of patients without known CAD who underwent CCTA or SPECT was performed. Patients who underwent CCTA (n = 1,938) were matched to those who underwent SPECT (n = 7,752) on 8 demographic and clinical characteristics and 2 summary measures of cardiac medications and co-morbidities and were evaluated for 9-month expenditures and clinical outcomes. Adjusted total health care and CAD expenditures were 27% (p <0.001) and 33% (p <0.001) lower, respectively, for patients who underwent CCTA compared with those who underwent SPECT, by an average of $467 (95% confidence interval $99 to $984) for CAD expenditures per patient. Despite lower total health care expenditures for CCTA, no differences were observed for rates of adverse cardiovascular events, including CAD hospitalizations (4.2% vs 4.1%, p = NS), CAD outpatient visits (17.4% vs 13.3%, p = NS), myocardial infarction (0.4% vs 0.6%, p = NS), and new-onset angina (3.0% vs 3.5%, p = NS). Patients without known CAD who underwent CCTA, compared with matched patients who underwent SPECT, incurred lower overall health care and CAD expenditures while experiencing similarly low rates of CAD hospitalization, outpatient visits, myocardial infarction, and angina. In conclusion, these data suggest that CCTA may be a cost-efficient alternative to SPECT for the initial coronary evaluation of patients without known CAD.

  6. Computerized optimization of multiple isocentres in stereotactic convergent beam irradiation

    NASA Astrophysics Data System (ADS)

    Treuer, U.; Treuer, H.; Hoevels, M.; Müller, R. P.; Sturm, V.

    1998-01-01

    A method for the fully computerized determination and optimization of positions of target points and collimator sizes in convergent beam irradiation is presented. In conventional interactive trial and error methods, which are very time consuming, the treatment parameters are chosen according to the operator's experience and improved successively. This time is reduced significantly by the use of a computerized procedure. After the definition of target volume and organs at risk in the CT or MR scans, an initial configuration is created automatically. In the next step the target point positions and collimator diameters are optimized by the program. The aim of the optimization is to find a configuration for which a prescribed dose at the target surface is approximated as close as possible. At the same time dose peaks inside the target volume are minimized and organs at risk and tissue surrounding the target are spared. To enhance the speed of the optimization a fast method for approximate dose calculation in convergent beam irradiation is used. A possible application of the method for calculating the leaf positions when irradiating with a micromultileaf collimator is briefly discussed. The success of the procedure has been demonstrated for several clinical cases with up to six target points.

  7. Computerized stroop test to assess selective attention in children with attention deficit hyperactivity disorder.

    PubMed

    Assef, Ellen Carolina dos Santos; Capovilla, Alessandra Gotuzo Seabra; Capovilla, Fernando Cesar

    2007-05-01

    Research shows abnormal function of the pre-frontal cortex in Attention Deficit Hyperactivity Disorder (ADHD). This cortex is involved in the control of executive functions related to planning and execution of goal-oriented strategies, working memory, inhibitions, cognitive flexibility, and selective attention. Selective attention involves focus on the target stimulus, ignoring competing distractions. The Stroop Test (Stroop, 1935) is usually used to evaluate selective attention. This study investigated whether children with ADHD could exhibit modified performance in the Stroop Test. Using a computerized version of this test (Capovilla, Montiel, Macedo, & Charin, 2005), the study compared the reaction times (RTs) of 62 Brazilian children, between 8 and 12 years of age, 31 of whom were diagnosed with ADHD and sent to psychiatric clinics, and 31 without ADHD studying in regular schools. All children with ADHD satisfied the criteria of the DSM-IV-TR and were evaluated with the Conners Abbreviated Questionnaire (Goyette, Conners, & Ulrich, 1978), completed by parents and teachers. The results revealed that children with ADHD exhibit greater interference in RT than children without ADHD. This corroborated the hypothesis that children with ADHD exhibit a deficit in selective attention, consisting in augmented RTs, as measured by the Computerized Stroop Test.

  8. Virtual reality simulation: using three-dimensional technology to teach nursing students.

    PubMed

    Jenson, Carole E; Forsyth, Diane McNally

    2012-06-01

    The use of computerized technology is rapidly growing in the classroom and in healthcare. An emerging computer technology strategy for nursing education is the use of virtual reality simulation. This computer-based three-dimensional educational tool simulates real-life patient experiences in a risk-free environment, allows for repeated practice sessions, requires clinical decision making, exposes students to diverse patient conditions, provides immediate feedback, and is portable. The purpose of this article was to review the importance of virtual reality simulation as a computerized teaching strategy. In addition, a project to explore readiness of nursing faculty at one major Midwestern university for the use of virtual reality simulation as a computerized teaching strategy is described where faculty thought virtual reality simulation would increase students' knowledge of an intravenous line insertion procedure. Faculty who practiced intravenous catheter insertion via virtual reality simulation expressed a wide range of learning experiences from using virtual reality simulation that is congruent with the literature regarding the barriers to student learning. Innovative teaching strategies, such as virtual reality simulation, address barriers of increasing patient acuity, high student-to-faculty ratio, patient safety concerns from faculty, and student anxiety and can offer rapid feedback to students.

  9. First results from the ionospheric tomography experiment using beacon TEC data obtained by means of a network along a longitude of 136°E over Japan

    NASA Astrophysics Data System (ADS)

    Thampi, Smitha V.; Yamamoto, Mamoru

    2010-03-01

    A chain of newly designed GNU (GNU is not UNIX) Radio Beacon Receivers (GRBR) has recently been established over Japan, primarily for tomographic imaging of the ionosphere over this region. Receivers installed at Shionomisaki (33.45°N, 135.8°E), Shigaraki (34.8°N, 136.1°E), and Fukui (36°N, 136°E) continuously track low earth orbiting satellites (LEOS), mainly OSCAR, Cosmos, and FORMOSAT-3/COSMIC, to obtain simultaneous total electron content (TEC) data from these three locations, which are then used for the tomographic reconstruction of ionospheric electron densities. This is the first GRBR network established for TEC observations, and the first beacon-based tomographic imaging in Japanese longitudes. The first tomographic images revealed the temporal evolution with all of the major features in the ionospheric electron density distribution over Japan. A comparison of the tomographically reconstructed electron densities with the ƒ o F 2 data from Kokubunji (35°N, 139°E) revealed that there was good agreement between the datasets. These first results show the potential of GRBR and its network for making continuous, unattended ionospheric TEC measurements and for tomographic imaging of the ionosphere.

  10. On the feasibility of tomographic-PIV with low pulse energy illumination in a lifted turbulent jet flame

    NASA Astrophysics Data System (ADS)

    Boxx, I.; Carter, C. D.; Meier, W.

    2014-08-01

    Tomographic particle image velocimetry (tomographic-PIV) is a recently developed measurement technique used to acquire volumetric velocity field data in liquid and gaseous flows. The technique relies on line-of-sight reconstruction of the rays between a 3D particle distribution and a multi-camera imaging system. In a turbulent flame, however, index-of-refraction variations resulting from local heat-release may inhibit reconstruction and thereby render the technique infeasible. The objective of this study was to test the efficacy of tomographic-PIV in a turbulent flame. An additional goal was to determine the feasibility of acquiring usable tomographic-PIV measurements in a turbulent flame at multi-kHz acquisition rates with current-generation laser and camera technology. To this end, a setup consisting of four complementary metal oxide semiconductor cameras and a dual-cavity Nd:YAG laser was implemented to test the technique in a lifted turbulent jet flame. While the cameras were capable of kHz-rate image acquisition, the laser operated at a pulse repetition rate of only 10 Hz. However, use of this laser allowed exploration of the required pulse energy and thus power for a kHz-rate system. The imaged region was 29 × 28 × 2.7 mm in size. The tomographic reconstruction of the 3D particle distributions was accomplished using the multiplicative algebraic reconstruction technique. The results indicate that volumetric velocimetry via tomographic-PIV is feasible with pulse energies of 25 mJ, which is within the capability of current-generation kHz-rate diode-pumped solid-state lasers.

  11. Large-scale tomographic particle image velocimetry using helium-filled soap bubbles

    NASA Astrophysics Data System (ADS)

    Kühn, Matthias; Ehrenfried, Klaus; Bosbach, Johannes; Wagner, Claus

    2011-04-01

    To measure large-scale flow structures in air, a tomographic particle image velocimetry (tomographic PIV) system for measurement volumes of the order of one cubic metre is developed, which employs helium-filled soap bubbles (HFSBs) as tracer particles. The technique has several specific characteristics compared to most conventional tomographic PIV systems, which are usually applied to small measurement volumes. One of them is spot lights on the HFSB tracers, which slightly change their position, when the direction of observation is altered. Further issues are the large particle to voxel ratio and the short focal length of the used camera lenses, which result in a noticeable variation of the magnification factor in volume depth direction. Taking the specific characteristics of the HFSBs into account, the feasibility of our large-scale tomographic PIV system is demonstrated by showing that the calibration errors can be reduced down to 0.1 pixels as required. Further, an accurate and fast implementation of the multiplicative algebraic reconstruction technique, which calculates the weighting coefficients when needed instead of storing them, is discussed. The tomographic PIV system is applied to measure forced convection in a convection cell at a Reynolds number of 530 based on the inlet channel height and the mean inlet velocity. The size of the measurement volume and the interrogation volumes amount to 750 mm × 450 mm × 165 mm and 48 mm × 48 mm × 24 mm, respectively. Validation of the tomographic PIV technique employing HFSBs is further provided by comparing profiles of the mean velocity and of the root mean square velocity fluctuations to respective planar PIV data.

  12. The computerized adaptive diagnostic test for major depressive disorder (CAD-MDD): a screening tool for depression.

    PubMed

    Gibbons, Robert D; Hooker, Giles; Finkelman, Matthew D; Weiss, David J; Pilkonis, Paul A; Frank, Ellen; Moore, Tara; Kupfer, David J

    2013-07-01

    To develop a computerized adaptive diagnostic screening tool for depression that decreases patient and clinician burden and increases sensitivity and specificity for clinician-based DSM-IV diagnosis of major depressive disorder (MDD). 656 individuals with and without minor and major depression were recruited from a psychiatric clinic and a community mental health center and through public announcements (controls without depression). The focus of the study was the development of the Computerized Adaptive Diagnostic Test for Major Depressive Disorder (CAD-MDD) diagnostic screening tool based on a decision-theoretical approach (random forests and decision trees). The item bank consisted of 88 depression scale items drawn from 73 depression measures. Sensitivity and specificity for predicting clinician-based Structured Clinical Interview for DSM-IV Axis I Disorders diagnoses of MDD were the primary outcomes. Diagnostic screening accuracy was then compared to that of the Patient Health Questionnaire-9 (PHQ-9). An average of 4 items per participant was required (maximum of 6 items). Overall sensitivity and specificity were 0.95 and 0.87, respectively. For the PHQ-9, sensitivity was 0.70 and specificity was 0.91. High sensitivity and reasonable specificity for a clinician-based DSM-IV diagnosis of depression can be obtained using an average of 4 adaptively administered self-report items in less than 1 minute. Relative to the currently used PHQ-9, the CAD-MDD dramatically increased sensitivity while maintaining similar specificity. As such, the CAD-MDD will identify more true positives (lower false-negative rate) than the PHQ-9 using half the number of items. Inexpensive (relative to clinical assessment), efficient, and accurate screening of depression in the settings of primary care, psychiatric epidemiology, molecular genetics, and global health are all direct applications of the current system. © Copyright 2013 Physicians Postgraduate Press, Inc.

  13. Computerized symptom and quality-of-life assessment for patients with cancer part I: development and pilot testing.

    PubMed

    Berry, Donna L; Trigg, Lisa J; Lober, William B; Karras, Bryant T; Galligan, Mary L; Austin-Seymour, Mary; Martin, Stephanie

    2004-09-01

    To develop and test an innovative computerized symptom and quality-of-life (QOL) assessment for patients with cancer who are evaluated for and treated with radiation therapy. Descriptive, longitudinal prototype development and cross-sectional clinical data. Department of radiation oncology in an urban, academic medical center. 101 outpatients who were evaluated for radiation therapy, able to communicate in English (or through one of many interpreters available at the University of Washington), and competent to understand the study information and give informed consent. Six clinicians caring for the patients in the sample were enrolled. Iterative prototype development was conducted using a standing focus group of clinicians. The software was developed based on survey markup language and implemented in a wireless, Web-based format. Patient participants completed the computerized assessment prior to consultation with the radiation physician. Graphical output pages with flagged areas of symptom distress or troublesome QOL issues were made available to consulting physicians and nurses. Pain intensity, symptoms, QOL, and demographics. Computerized versions of a 0 to 10 Pain Intensity Numerical Scale (PINS), Symptom Distress Scale, and Short Form-8. Focus group recommendations included clinician priorities of brevity, flexibility, and simplicity for both input interface and output and that the assessment output contain color graphic display. Patient participants included 45 women and 56 men with a mean age of 52.7 years (SD = 13.8). Fewer than half of the participants (40%) reported using a computer on a regular basis (weekly or daily). Completion time averaged 7.8 minutes (SD = 3.7). Moderate to high levels of distress were reported more often for fatigue, pain, and emotional issues than for other symptoms or concerns. Computerized assessment of cancer symptoms and QOL is technically possible and feasible in an ambulatory cancer clinic. A wireless, Web-based system facilitates access to results and data entry and retrieval. The symptom and QOL profiles of these patients new to radiation therapy were comparable to other samples of outpatients with cancer. The ability to capture an easily interpreted illustration of a patients symptom and QOL experience in less than 10 minutes is a potentially useful adjunct to traditional face-to-face interviewing. Ultimately, electronic patient-generated data could produce automated red flags directed to the most appropriate clinicians (e.g., nurse, pain specialist, social worker, nutritionist) for further evaluation. Such system enhancement could greatly facilitate oncology nurses coordination role in caring for complex patients with cancer.

  14. Impact of vendor computerized physician order entry on patients with renal impairment in community hospitals.

    PubMed

    Leung, Alexander A; Schiff, Gordon; Keohane, Carol; Amato, Mary; Simon, Steven R; Cadet, Bismarck; Coffey, Michael; Kaufman, Nathan; Zimlichman, Eyal; Seger, Diane L; Yoon, Catherine; Bates, David W

    2013-10-01

    Adverse drug events (ADEs) are common among hospitalized patients with renal impairment. To determine whether computerized physician order entry (CPOE) systems with clinical decision support capabilities reduce the frequency of renally related ADEs in hospitals. Quasi-experimental study of 1590 adult patients with renal impairment who were admitted to 5 community hospitals in Massachusetts from January 2005 to September 2010, preimplementation and postimplementation of CPOE. Varying levels of clinical decision support, ranging from basic CPOE only (sites 4 and 5), rudimentary clinical decision support (sites 1 and 2), and advanced clinical decision support (site 3). Primary outcome was the rate of preventable ADEs from nephrotoxic and/or renally cleared medications. Similarly, secondary outcomes were the rates of overall ADEs and potential ADEs. There was a 45% decrease in the rate of preventable ADEs following implementation (8.0/100 vs 4.4/100 admissions; P < 0.01), and the impact was related to the level of decision support. Basic CPOE was not associated with any significant benefit (4.6/100 vs 4.3/100 admissions; P = 0.87). There was a nonsignificant decrease in preventable ADEs with rudimentary clinical decision support (9.1/100 vs 6.4/100 admissions; P = 0.22). However, substantial reduction was seen with advanced clinical decision support (12.4/100 vs 0/100 admissions; P = 0.01). Despite these benefits, a significant increase in potential ADEs was found for all systems (55.5/100 vs 136.8/100 admissions; P < 0.01). Vendor-developed CPOE with advanced clinical decision support can reduce the occurrence of preventable ADEs but may be associated with an increase in potential ADEs. © 2013 Society of Hospital Medicine.

  15. Leveraging Electronic Tablets for General Pediatric Care

    PubMed Central

    McKee, S.; Dugan, T.M.; Downs, S.M.

    2015-01-01

    Summary Background We have previously shown that a scan-able paper based interface linked to a computerized clinical decision support system (CDSS) can effectively screen patients in pediatric waiting rooms and support the physician using evidence based care guidelines at the time of clinical encounter. However, the use of scan-able paper based interface has many inherent limitations including lacking real time communication with the CDSS and being prone to human and system errors. An electronic tablet based user interface can not only overcome these limitations, but may also support advanced functionality for clinical and research use. However, use of such devices for pediatric care is not well studied in clinical settings. Objective In this pilot study, we enhance our pediatric CDSS with an electronic tablet based user interface and evaluate it for usability as well as for changes in patient questionnaire completion rates. Methods Child Health Improvement through Computers Leveraging Electronic Tablets or CHICLET is an electronic tablet based user interface. It is developed to augment the existing scan-able paper interface to our CDSS. For the purposes of this study, we deployed CHICLET in one outpatient pediatric clinic. Usability factors for CHICLET were evaluated via caregiver and staff surveys. Results When compared to the scan-able paper based interface, we observed an 18% increase or 30% relative increase in question completion rates using CHICLET. This difference was statistically significant. Caregivers and staff survey results were positive for using CHICLET in clinical environment. Conclusions Electronic tablets are a viable interface for capturing patient self-report in pediatric waiting rooms. We further hypothesize that the use of electronic tablet based interfaces will drive advances in computerized clinical decision support and create opportunities for patient engagement. PMID:25848409

  16. Supervision and computerized neurocognitive baseline test performance in high school athletes: an initial investigation.

    PubMed

    Kuhn, Andrew Warren; Solomon, Gary S

    2014-01-01

    Computerized neuropsychological testing batteries have provided a time-efficient and cost-efficient way to assess and manage the neurocognitive aspects of patients with sport-related concussion. These tests are straightforward and mostly self-guided, reducing the degree of clinician involvement required by traditional clinical neuropsychological paper-and-pencil tests. To determine if self-reported supervision status affected computerized neurocognitive baseline test performance in high school athletes. Retrospective cohort study. Supervised testing took place in high school computer libraries or sports medicine clinics. Unsupervised testing took place at the participant's home or another location with computer access. From 2007 to 2012, high school athletes across middle Tennessee (n = 3771) completed computerized neurocognitive baseline testing (Immediate Post-Concussion Assessment and Cognitive Testing [ImPACT]). They reported taking the test either supervised by a sports medicine professional or unsupervised. These athletes (n = 2140) were subjected to inclusion and exclusion criteria and then matched based on age, sex, and number of prior concussions. We extracted demographic and performance-based data from each de-identified baseline testing record. Paired t tests were performed between the self-reported supervised and unsupervised groups, comparing the following ImPACT baseline composite scores: verbal memory, visual memory, visual motor (processing) speed, reaction time, impulse control, and total symptom score. For differences that reached P < .05, the Cohen d was calculated to measure the effect size. Lastly, a χ(2) analysis was conducted to compare the rate of invalid baseline testing between the groups. All statistical tests were performed at the 95% confidence interval level. Self-reported supervised athletes demonstrated better visual motor (processing) speed (P = .004; 95% confidence interval [0.28, 1.52]; d = 0.12) and faster reaction time (P < .001; 95% confidence interval [-0.026, -0.014]; d = 0.21) composite scores than self-reported unsupervised athletes. Speed-based tasks were most affected by self-reported supervision status, although the effect sizes were relatively small. These data lend credence to the hypothesis that supervision status may be a factor in the evaluation of ImPACT baseline test scores.

  17. 11 CFR 9033.12 - Production of computerized information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... magnetic media, such as magnetic tapes or magnetic diskettes, containing the computerized information at.... The computerized magnetic media shall be prepared and delivered at the committee's expense and shall... Commission's Computerized Magnetic Media Requirements for title 26 Candidates/Committees Receiving Federal...

  18. SIRT-FILTER v1.0.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PELT, DANIEL

    2017-04-21

    Small Python package to compute tomographic reconstructions using a reconstruction method published in: Pelt, D.M., & De Andrade, V. (2017). Improved tomographic reconstruction of large-scale real-world data by filter optimization. Advanced Structural and Chemical Imaging 2: 17; and Pelt, D. M., & Batenburg, K. J. (2015). Accurately approximating algebraic tomographic reconstruction by filtered backprojection. In Proceedings of The 13th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (pp. 158-161).

  19. CEDRIC: a computerized chronic disease management system for urban, safety net clinics.

    PubMed

    Ogunyemi, Omolola; Mukherjee, Sukrit; Ani, Chizobam; Hindman, David; George, Sheba; Ilapakurthi, Ramarao; Verma, Mary; Dayrit, Melvin

    2010-01-01

    To meet the challenge of improving health care quality in urban, medically underserved areas of the US that have a predominance of chronic diseases such as diabetes, we have developed a new information system called CEDRIC for managing chronic diseases. CEDRIC was developed in collaboration with clinicians at an urban safety net clinic, using a community-participatory partnered research approach, with a view to addressing the particular needs of urban clinics with a high physician turnover and large uninsured/underinsured patient population. The pilot implementation focuses on diabetes management. In this paper, we describe the system's architecture and features.

  20. Computer-Based Oral Hygiene Instruction versus Verbal Method in Fixed Orthodontic Patients

    PubMed Central

    Moshkelgosha, V.; Mehrvarz, Sh.; Saki, M.; Golkari, A.

    2017-01-01

    Statement of Problem: Fixed orthodontic appliances in the oral cavity make tooth cleaning procedures more complicated. Objectives: This study aimed to compare the efficacy of computerized oral hygiene instruction with verbal technique among fixed orthodontic patients referred to the evening clinic of Orthodontics of Shiraz Dental School. Materials and Methods: A single-blind study was performed in Orthodontic Department of Shiraz, Islamic Republic of Iran, from January to May 2015 following the demonstrated exclusion and inclusion criteria. The sample size was considered 60 patients with 30 subjects in each group. Bleeding on probing and plaque indices and dental knowledge were assessed in the subjects to determine pre-intervention status. A questionnaire was designed for dental knowledge evaluation. The patients were randomly assigned into the computerized and verbal groups. Three weeks after the oral hygiene instruction, indices of bleeding on probing and plaque index and the dental knowledge were evaluated to investigate post-intervention outcome. The two groups were compared by chi-square and student t tests. The pre- and post-intervention scores in each group were compared using paired t-test. Results: In the computerized group, the mean score for plaque index and bleeding on probing index was significantly decreased while dental health knowledge was significantly increased after oral hygiene instruction, in contrast to the verbal group. Conclusions: Within the limitations of the current study, computerized oral hygiene instruction is proposed to be more effective in providing optimal oral health status compared to the conventional method in fixed orthodontic patients. PMID:28959765

  1. “Computerized Counseling Reduces HIV-1 Viral Load and Sexual Transmission Risk: Findings from a Randomized Controlled Trial”

    PubMed Central

    KURTH, Ann E.; SPIELBERG, Freya; CLELAND, Charles M.; LAMBDIN, Barrot; BANGSBERG, David R.; FRICK, Pamela A.; SEVERYNEN, Anneleen O.; CLAUSEN, Marc; NORMAN, Robert G.; LOCKHART, David; SIMONI, Jane M.; HOLMES, King K.

    2014-01-01

    Objective Evaluate a computerized intervention supporting antiretroviral therapy (ART) adherence and HIV transmission prevention. Design Longitudinal RCT. Settings An academic HIV clinic and a community-based organization in Seattle. Subjects 240 HIV-positive adults on ART; 209 completed nine-month follow-up (87% retention). Intervention Randomization to computerized counseling or assessment-only, 4 sessions over 9 months. Main Outcome Measures HIV-1 viral suppression, and self-reported ART adherence, and transmission risks, compared using generalized estimating equations. Results Overall, intervention participants had reduced viral load (VL): mean 0.17 log10 decline, versus 0.13 increase in controls, p = 0.053, and significant difference in ART adherence baseline to 9 months (p = 0.046). Their sexual transmission risk behaviors decreased (OR = 0.55, p = 0.020), a reduction not seen among controls (OR = 1.1, p = 0.664), and a significant difference in change (p = 0.040). Intervention effect was driven by those most in need: among those with detectable virus at baseline (>30 copies/milliliter, n=89), intervention effect was mean 0.60 log10 VL decline versus 0.15 increase in controls, p=0.034. ART adherence at the final follow-up was 13 points higher among intervention participants versus controls, p = 0.038. Conclusions Computerized counseling is promising for integrated ART adherence and safer sex, especially for individuals with problems in these areas. This is the first intervention to report improved ART adherence, viral suppression, and reduced secondary sexual transmission risk behavior. PMID:24384803

  2. Quantitation of mandibular ramus volume as a source of bone grafting.

    PubMed

    Verdugo, Fernando; Simonian, Krikor; Smith McDonald, Roberto; Nowzari, Hessam

    2009-10-01

    When alveolar atrophy impairs dental implant placement, ridge augmentation using mandibular ramus graft may be considered. In live patients, however, an accurate calculation of the amount of bone that can be safely harvested from the ramus has not been reported. The use of a software program to perform these calculations can aid in preventing surgical complications. The aim of the present study was to intra-surgically quantify the volume of the ramus bone graft that can be safely harvested in live patients, and compare it to presurgical computerized tomographic calculations. The AutoCAD software program quantified ramus bone graft in 40 consecutive patients from computerized tomographies. Direct intra-surgical measurements were recorded thereafter and compared to software data (n = 10). In these 10 patients, the bone volume was also measured at the recipient sites 6 months post-sinus augmentation. The mandibular second and third molar areas provided the thickest cortical graft averaging 2.8 +/- 0.6 mm. The thinnest bone was immediately posterior to the third molar (1.9 +/- 0.3 mm). The volume of ramus bone graft measured by AutoCAD averaged 0.8 mL (standard deviation [SD] 0.2 mL, range: 0.4-1.2 mL). The volume of bone graft measured intra-surgically averaged 2.5 mL (SD 0.4 mL, range: 1.8-3.0 mL). The difference between the two measurement methods was significant (p < 0.001). The bone volume measured 6 months post-sinus augmentation averaged 2.2 mL (SD 0.4 mL, range: 1.6-2.8 mL) with a mean loss of 0.3 mL in volume. The mandibular second molar area provided the thickest cortical graft. A cortical plate of 2.8 mm in average at combined second and third molar areas provided 2.5 mL particulated volume. The use of a design software program can improve surgical treatment planning prior to ramus bone grafting. The AutoCAD software program did not overestimate the volume of bone that can be safely harvested from the mandibular ramus.

  3. TU-AB-207-03: Tomosynthesis: Clinical Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maidment, A.

    2015-06-15

    Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact,more » the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.« less

  4. Video analysis of the biomechanics of a bicycle accident resulting in significant facial fractures.

    PubMed

    Syed, Shameer H; Willing, Ryan; Jenkyn, Thomas R; Yazdani, Arjang

    2013-11-01

    This study aimed to use video analysis techniques to determine the velocity, impact force, angle of impact, and impulse to fracture involved in a video-recorded bicycle accident resulting in facial fractures. Computed tomographic images of the resulting facial injury are presented for correlation with data and calculations. To our knowledge, such an analysis of an actual recorded trauma has not been reported in the literature. A video recording of the accident was split into frames and analyzed using an image editing program. Measurements of velocity and angle of impact were obtained from this analysis, and the force of impact and impulse were calculated using the inverse dynamic method with connected rigid body segments. These results were then correlated with the actual fracture pattern found on computed tomographic imaging of the subject's face. There was an impact velocity of 6.25 m/s, impact angles of 14 and 6.3 degrees of neck extension and axial rotation, respectively, an impact force of 1910.4 N, and an impulse to fracture of 47.8 Ns. These physical parameters resulted in clinically significant bilateral mid-facial Le Fort II and III pattern fractures. These data confer further understanding of the biomechanics of bicycle-related accidents by correlating an actual clinical outcome with the kinematic and dynamic parameters involved in the accident itself and yielding a concrete evidence of the velocity, force, and impulse necessary to cause clinically significant facial trauma. These findings can aid in the design of protective equipment for bicycle riders to help avoid this type of injury.

  5. Central tarsal bone fractures in horses not used for racing: Computed tomographic configuration and long-term outcome of lag screw fixation.

    PubMed

    Gunst, S; Del Chicca, F; Fürst, A E; Kuemmerle, J M

    2016-09-01

    There are no reports on the configuration of equine central tarsal bone fractures based on cross-sectional imaging and clinical and radiographic long-term outcome after internal fixation. To report clinical, radiographic and computed tomographic findings of equine central tarsal bone fractures and to evaluate the long-term outcome of internal fixation. Retrospective case series. All horses diagnosed with a central tarsal bone fracture at our institution in 2009-2013 were included. Computed tomography and internal fixation using lag screw technique was performed in all patients. Medical records and diagnostic images were reviewed retrospectively. A clinical and radiographic follow-up examination was performed at least 1 year post operatively. A central tarsal bone fracture was diagnosed in 6 horses. Five were Warmbloods used for showjumping and one was a Quarter Horse used for reining. All horses had sagittal slab fractures that began dorsally, ran in a plantar or plantaromedial direction and exited the plantar cortex at the plantar or plantaromedial indentation of the central tarsal bone. Marked sclerosis of the central tarsal bone was diagnosed in all patients. At long-term follow-up, 5/6 horses were sound and used as intended although mild osteophyte formation at the distal intertarsal joint was commonly observed. Central tarsal bone fractures in nonracehorses had a distinct configuration but radiographically subtle additional fracture lines can occur. A chronic stress related aetiology seems likely. Internal fixation of these fractures based on an accurate diagnosis of the individual fracture configuration resulted in a very good prognosis. © 2015 EVJ Ltd.

  6. A review of US anthropometric reference data (1971 2000) with comparisons to both stylized and tomographic anatomic models

    NASA Astrophysics Data System (ADS)

    Huh, C.; Bolch, W. E.

    2003-10-01

    Two classes of anatomic models currently exist for use in both radiation protection and radiation dose reconstruction: stylized mathematical models and tomographic voxel models. The former utilize 3D surface equations to represent internal organ structure and external body shape, while the latter are based on segmented CT or MR images of a single individual. While tomographic models are clearly more anthropomorphic than stylized models, a given model's characterization as being anthropometric is dependent upon the reference human to which the model is compared. In the present study, data on total body mass, standing/sitting heights and body mass index are collected and reviewed for the US population covering the time interval from 1971 to 2000. These same anthropometric parameters are then assembled for the ORNL series of stylized models, the GSF series of tomographic models (Golem, Helga, Donna, etc), the adult male Zubal tomographic model and the UF newborn tomographic model. The stylized ORNL models of the adult male and female are found to be fairly representative of present-day average US males and females, respectively, in terms of both standing and sitting heights for ages between 20 and 60-80 years. While the ORNL adult male model provides a reasonably close match to the total body mass of the average US 21-year-old male (within ~5%), present-day 40-year-old males have an average total body mass that is ~16% higher. For radiation protection purposes, the use of the larger 73.7 kg adult ORNL stylized hermaphrodite model provides a much closer representation of average present-day US females at ages ranging from 20 to 70 years. In terms of the adult tomographic models from the GSF series, only Donna (40-year-old F) closely matches her age-matched US counterpart in terms of average body mass. Regarding standing heights, the better matches to US age-correlated averages belong to Irene (32-year-old F) for the females and Golem (38-year-old M) for the males. Both Helga (27-year-old F) and Donna, however, provide good matches to average US sitting heights for adult females, while Golem and Otoko (male of unknown age) yield sitting heights that are slightly below US adult male averages. Finally, Helga is seen as the only GSF tomographic female model that yields a body mass index in line with her average US female counterpart at age 26. In terms of dose reconstruction activities, however, all current tomographic voxel models are valuable assets in attempting to cover the broad distribution of individual anthropometric parameters representative of the current US population. It is highly recommended that similar attempts to create a broad library of tomographic models be initiated in the United States and elsewhere to complement and extend the limited number of tomographic models presently available for these efforts.

  7. MedEthEx Online: A Computer-based Learning Program in Medical Ethics and Communication Skills.

    ERIC Educational Resources Information Center

    Fleetwood, Janet; Vaught, Wayne; Feldman, Debra; Gracely, Edward; Kassutto, Zach; Novack, Dennis

    2000-01-01

    Assessed MedEthEx Online, a computer-based learning program, in improving communication skills as part of a required bioethics course for medical students. Exam scores of users were comparable with non-users, although computerized-learning students scored higher in specific exam areas, felt somewhat more clinically prepared, and rated the course…

  8. Clinical Use of the Pediatric Attention Disorders Diagnostic Screener for Children at Risk for Attention Deficit Hyperactivity Disorder: Case Illustrations

    ERIC Educational Resources Information Center

    Keiser, Ashley; Reddy, Linda

    2013-01-01

    The Pediatric Attention Disorders Diagnostic Screener is a multidimensional, computerized screening tool designed to assess attention and global aspects of executive functioning in children at risk for attention disorders. The screener consists of a semi-structured diagnostic interview, brief parent and teacher rating scales, 3 computer-based…

  9. Asymptomatic Emphysematous Pyelonephritis - Positron Emission Tomography Computerized Tomography Aided Diagnostic and Therapeutic Elucidation

    PubMed Central

    Pathapati, Deepti; Shinkar, Pawan Gulabrao; kumar, Satya Awadhesh; Jha; Dattatreya, Palanki Satya; Chigurupati, Namrata; Chigurupati, Mohana Vamsy; Rao, Vatturi Venkata Satya Prabhakar

    2017-01-01

    The authors report an interesting coincidental unearthing by 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) of a potentially serious medical condition of emphysematous pyelonephritis in a case of nasopharyngeal carcinoma. The management by conservative ureteric stenting and antibiotics was done with gratifying clinical outcome. PMID:28242985

  10. [The computed tomographic semiotics of inflammatory diseases of the adnexa uteri].

    PubMed

    Todua, F I; Karmazanovskiĭ, G G; Podzolkova, N M

    1990-01-01

    The authors sum up the results of CT and clinical investigation of 46 women with inflammatory diseases of the uterine appendages: salpingo-oophoritis, pyosalpinx, pyoovarium, and 2 types of tuboovarian abscesses. They have shown CT potentialities in differential diagnosis of inflammations of the uterine appendages with cysts and true ovarian tumors on the basis of routine investigation and an iv contrast study of intensified images. Retrospective analysis of the most typical diagnostic errors is given.

  11. Cerebellar syndrome with hydrocephalus due to Mycoplasma pneumoniae infection.

    PubMed Central

    Coleman, R. J.; Brown, J. S.; Butler, P.; Swash, M.

    1990-01-01

    A 27 year old woman developed a cerebellar syndrome with serological evidence of recent Mycoplasma pneumoniae infection. The cranial computed tomographic scan showed effacement of the fourth ventricle, enhancement of the basal meninges and hydrocephalus affecting the lateral and third ventricles. Clinical and radiological recovery occurred over 5 weeks. We propose that this was a manifestation of immune-mediated encephalomyelitis induced by the infection rather than direct invasion of the central nervous system. Images Figure 1 PMID:2217014

  12. 39 CFR 501.15 - Computerized Meter Resetting System.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15...

  13. The use of a computed tomographic application for mobile devices in the diagnosis of oral and maxillofacial surgery.

    PubMed

    Aoki, Eduardo Massaharu; Cortes, Arthur Rodriguez Gonzalez; Arita, Emiko Saito

    2015-01-01

    The aim of the current technical report was to introduce a computed tomographic (CT) application for mobile devices as a diagnostic tool for analyzing CT images. An iPad and an iPhone (Apple, Cuppertino, CA) were used to navigate through multiplanar reconstructions of cone beam CT scans, using an application derived from the OsiriX CT software. Tools and advantages of this method were recorded. In addition, images rendered in the iPad were manipulated during dental implant placement and grafting procedures to follow up and confirm the implant digital planning in real time. The study population consisted of 10 patients. In all cases, it was possible to use image manipulation tools, such as changing contrast and brightness, zooming, rotating, panning, performing both linear and area measurements, and analyzing gray-scale values of a region of interest. Furthermore, it was possible to use the OsiriX application in the dental clinic where the study was conducted, to follow-up the analyzed implant placement and grafting procedures at the chairside. The current findings suggest that technological and practical methods to visualize radiographic images are invaluable resources to improve training, teaching, networking, and the performance of real-time follow-up of oral and maxillofacial surgical procedures. This article discusses the advantages and disadvantages of introducing this new technology in the clinical routine.

  14. A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology

    NASA Astrophysics Data System (ADS)

    Staton, R. J.; Pazik, F. D.; Nipper, J. C.; Williams, J. L.; Bolch, W. E.

    2003-04-01

    Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult.

  15. High-Energy, High-Pulse-Rate Light Sources for Enhanced Time-Resolved Tomographic PIV of Unsteady and Turbulent Flows

    DTIC Science & Technology

    2017-07-31

    Report: High-Energy, High-Pulse-Rate Light Sources for Enhanced Time -Resolved Tomographic PIV of Unsteady & Turbulent Flows The views, opinions and/or...reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching...High-Energy, High-Pulse-Rate Light Sources for Enhanced Time -Resolved Tomographic PIV of Unsteady & Turbulent Flows Report Term: 0-Other Email

  16. Computerized provider order entry in the clinical laboratory

    PubMed Central

    Baron, Jason M.; Dighe, Anand S.

    2011-01-01

    Clinicians have traditionally ordered laboratory tests using paper-based orders and requisitions. However, paper orders are becoming increasingly incompatible with the complexities, challenges, and resource constraints of our modern healthcare systems and are being replaced by electronic order entry systems. Electronic systems that allow direct provider input of diagnostic testing or medication orders into a computer system are known as Computerized Provider Order Entry (CPOE) systems. Adoption of laboratory CPOE systems may offer institutions many benefits, including reduced test turnaround time, improved test utilization, and better adherence to practice guidelines. In this review, we outline the functionality of various CPOE implementations, review the reported benefits, and discuss strategies for using CPOE to improve the test ordering process. Further, we discuss barriers to the implementation of CPOE systems that have prevented their more widespread adoption. PMID:21886891

  17. Computerized Physician Order Entry

    PubMed Central

    Khanna, Raman; Yen, Tony

    2014-01-01

    Computerized physician order entry (CPOE) has been promoted as an important component of patient safety, quality improvement, and modernization of medical practice. In practice, however, CPOE affects health care delivery in complex ways, with benefits as well as risks. Every implementation of CPOE is associated with both generally recognized and unique local factors that can facilitate or confound its rollout, and neurohospitalists will often be at the forefront of such rollouts. In this article, we review the literature on CPOE, beginning with definitions and proceeding to comparisons to the standard of care. We then proceed to discuss clinical decision support systems, negative aspects of CPOE, and cultural context of CPOE implementation. Before concluding, we follow the experiences of a Chief Medical Information Officer and neurohospitalist who rolled out a CPOE system at his own health care organization and managed the resulting workflow changes and setbacks. PMID:24381708

  18. Magnetic resonance imaging and computerized tomography in malignant external otitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gherini, S.G.; Brackmann, D.E.; Bradley, W.G.

    1986-05-01

    In malignant external otitis (MEO), determining the anatomic extent of disease and evaluating the physiologic response to therapy remain a problem. Magnetic resonance imaging (MRI) has recently become available in limited clinical settings. Four patients with MEO were evaluated using MRI, computerized tomography (CT), technetium-99 (Tc-99) bone scanning, and gallium-67 citrate (Ga-67 citrate) scanning. MRI is superior to CT, Tc-99 bone scanning, and Ga-67 citrate scanning in evaluating the anatomic extent of soft tissue changes in MEO. MRI alone cannot be relied upon to determine the physiologic response to therapy. MRI can, however, serve as a valuable guide to themore » interpretation of Tc-99 bone and Ga-67 citrate scans, and in this respect, MRI is extremely useful in the treatment of MEO.« less

  19. Computerized system for assessing heart rate variability.

    PubMed

    Frigy, A; Incze, A; Brânzaniuc, E; Cotoi, S

    1996-01-01

    The principal theoretical, methodological and clinical aspects of heart rate variability (HRV) analysis are reviewed. This method has been developed over the last 10 years as a useful noninvasive method of measuring the activity of the autonomic nervous system. The main components and the functioning of the computerized rhythm-analyzer system developed by our team are presented. The system is able to perform short-term (maximum 20 minutes) time domain HRV analysis and statistical analysis of the ventricular rate in any rhythm, particularly in atrial fibrillation. The performances of our system are demonstrated by using the graphics (RR histograms, delta RR histograms, RR scattergrams) and the statistical parameters resulted from the processing of three ECG recordings. These recordings are obtained from a normal subject, from a patient with advanced heart failure, and from a patient with atrial fibrillation.

  20. Core drug-drug interaction alerts for inclusion in pediatric electronic health records with computerized prescriber order entry.

    PubMed

    Harper, Marvin B; Longhurst, Christopher A; McGuire, Troy L; Tarrago, Rod; Desai, Bimal R; Patterson, Al

    2014-03-01

    The study aims to develop a core set of pediatric drug-drug interaction (DDI) pairs for which electronic alerts should be presented to prescribers during the ordering process. A clinical decision support working group composed of Children's Hospital Association (CHA) members was developed. CHA Pharmacists and Chief Medical Information Officers participated. Consensus was reached on a core set of 19 DDI pairs that should be presented to pediatric prescribers during the order process. We have provided a core list of 19 high value drug pairs for electronic drug-drug interaction alerts to be recommended for inclusion as high value alerts in prescriber order entry software used with a pediatric patient population. We believe this list represents the most important pediatric drug interactions for practical implementation within computerized prescriber order entry systems.

  1. 21 CFR 884.2800 - Computerized Labor Monitoring System.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Computerized Labor Monitoring System. 884.2800... Devices § 884.2800 Computerized Labor Monitoring System. (a) Identification. A computerized labor monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and...

  2. Image processing pipeline for synchrotron-radiation-based tomographic microscopy.

    PubMed

    Hintermüller, C; Marone, F; Isenegger, A; Stampanoni, M

    2010-07-01

    With synchrotron-radiation-based tomographic microscopy, three-dimensional structures down to the micrometer level can be visualized. Tomographic data sets typically consist of 1000 to 1500 projections of 1024 x 1024 to 2048 x 2048 pixels and are acquired in 5-15 min. A processing pipeline has been developed to handle this large amount of data efficiently and to reconstruct the tomographic volume within a few minutes after the end of a scan. Just a few seconds after the raw data have been acquired, a selection of reconstructed slices is accessible through a web interface for preview and to fine tune the reconstruction parameters. The same interface allows initiation and control of the reconstruction process on the computer cluster. By integrating all programs and tools, required for tomographic reconstruction into the pipeline, the necessary user interaction is reduced to a minimum. The modularity of the pipeline allows functionality for new scan protocols to be added, such as an extended field of view, or new physical signals such as phase-contrast or dark-field imaging etc.

  3. Tomographic imaging of OH laser-induced fluorescence in laminar and turbulent jet flames

    NASA Astrophysics Data System (ADS)

    Li, Tao; Pareja, Jhon; Fuest, Frederik; Schütte, Manuel; Zhou, Yihui; Dreizler, Andreas; Böhm, Benjamin

    2018-01-01

    In this paper a new approach for 3D flame structure diagnostics using tomographic laser-induced fluorescence (Tomo-LIF) of the OH radical was evaluated. The approach combined volumetric illumination with a multi-camera detection system of eight views. Single-shot measurements were performed in a methane/air premixed laminar flame and in a non-premixed turbulent methane jet flame. 3D OH fluorescence distributions in the flames were reconstructed using the simultaneous multiplicative algebraic reconstruction technique. The tomographic measurements were compared and validated against results of OH-PLIF in the laminar flame. The effects of the experimental setup of the detection system and the size of the volumetric illumination on the quality of the tomographic reconstructions were evaluated. Results revealed that the Tomo-LIF is suitable for volumetric reconstruction of flame structures with acceptable spatial resolution and uncertainty. It was found that the number of views and their angular orientation have a strong influence on the quality and accuracy of the tomographic reconstruction while the illumination volume thickness influences mainly the spatial resolution.

  4. Patient-oriented Computerized Clinical Guidelines for Mobile Decision Support in Gestational Diabetes.

    PubMed

    García-Sáez, Gema; Rigla, Mercedes; Martínez-Sarriegui, Iñaki; Shalom, Erez; Peleg, Mor; Broens, Tom; Pons, Belén; Caballero-Ruíz, Estefanía; Gómez, Enrique J; Hernando, M Elena

    2014-03-01

    The risks associated with gestational diabetes (GD) can be reduced with an active treatment able to improve glycemic control. Advances in mobile health can provide new patient-centric models for GD to create personalized health care services, increase patient independence and improve patients' self-management capabilities, and potentially improve their treatment compliance. In these models, decision-support functions play an essential role. The telemedicine system MobiGuide provides personalized medical decision support for GD patients that is based on computerized clinical guidelines and adapted to a mobile environment. The patient's access to the system is supported by a smartphone-based application that enhances the efficiency and ease of use of the system. We formalized the GD guideline into a computer-interpretable guideline (CIG). We identified several workflows that provide decision-support functionalities to patients and 4 types of personalized advice to be delivered through a mobile application at home, which is a preliminary step to providing decision-support tools in a telemedicine system: (1) therapy, to help patients to comply with medical prescriptions; (2) monitoring, to help patients to comply with monitoring instructions; (3) clinical assessment, to inform patients about their health conditions; and (4) upcoming events, to deal with patients' personal context or special events. The whole process to specify patient-oriented decision support functionalities ensures that it is based on the knowledge contained in the GD clinical guideline and thus follows evidence-based recommendations but at the same time is patient-oriented, which could enhance clinical outcomes and patients' acceptance of the whole system. © 2014 Diabetes Technology Society.

  5. The Computerized Medical Record as a Tool for Clinical Governance in Australian Primary Care

    PubMed Central

    Phillips, Christine; Hall, Sally; Travaglia, Joanne

    2013-01-01

    Background Computerized medical records (CMR) are used in most Australian general practices. Although CMRs have the capacity to amalgamate and provide data to the clinician about their standard of care, there is little research on the way in which they may be used to support clinical governance: the process of ensuring quality and accountability that incorporates the obligation that patients are treated according to best evidence. Objective The objective of this study was to explore the capability, capacity, and acceptability of CMRs to support clinical governance. Methods We conducted a realist review of the role of seven CMR systems in implementing clinical governance, developing a four-level maturity model for the CMR. We took Australian primary care as the context, CMR to be the mechanism, and looked at outcomes for individual patients, localities, and for the population in terms of known evidence-based surrogates or true outcome measures. Results The lack of standardization of CMRs makes national and international benchmarking challenging. The use of the CMR was largely at level two of our maturity model, indicating a relatively simple system in which most of the process takes place outside of the CMR, and which has little capacity to support benchmarking, practice comparisons, and population-level activities. Although national standards for coding and projects for record access are proposed, they are not operationalized. Conclusions The current CMR systems can support clinical governance activities; however, unless the standardization and data quality issues are addressed, it will not be possible for current systems to work at higher levels. PMID:23939340

  6. Reflecting on the ethical administration of computerized medical records

    NASA Astrophysics Data System (ADS)

    Collmann, Jeff R.

    1995-05-01

    This presentation examines the ethical issues raised by computerized image management and communication systems (IMAC), the ethical principals that should guide development of policies, procedures and practices for IMACS systems, and who should be involved in developing a hospital's approach to these issues. The ready access of computerized records creates special hazards of which hospitals must beware. Hospitals must maintain confidentiality of patient's records while making records available to authorized users as efficiently as possible. The general conditions of contemporary health care undermine protecting the confidentiality of patient record. Patients may not provide health care institutions with information about themselves under conditions of informed consent. The field of information science must design sophisticated systems of computer security that stratify access, create audit trails on data changes and system use, safeguard patient data from corruption, and protect the databases from outside invasion. Radiology professionals must both work with information science experts in their own hospitals to create institutional safeguards and include the adequacy of security measures as a criterion for evaluating PACS systems. New policies and procedures on maintaining computerized patient records must be developed that obligate all members of the health care staff, not just care givers. Patients must be informed about the existence of computerized medical records, the rules and practices that govern their dissemination and given the opportunity to give or withhold consent for their use. Departmental and hospital policies on confidentiality should be reviewed to determine if revisions are necessary to manage computer-based records. Well developed discussions of the ethical principles and administrative policies on confidentiality and informed consent and of the risks posed by computer-based patient records systems should be included in initial and continuing staff system training. Administration should develop ways to monitor staff compliance with confidentiality policies and should assess diligence in maintaining patient record confidentiality as part of staff annual performance evaluations. Ethical management of IMAC systems is the business of all members of the health care team. Computerized patient records management (including IMAC) should be scrutinized as any other clinical medial ethical issue. If hospitals include these processes in their planning for RIS, IMACS, and HIS systems, they should have time to develop institutional expertise on these questions before and as systems are installed rather than only as ethical dilemmas develop during their use.

  7. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, James G.; Daily, William D.

    1994-01-01

    A method for simultaneously heating the subsurface and imaging the effects of the heating. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  8. Knowledge Translation of the PERC Rule for Suspected Pulmonary Embolism: A Blueprint for Reducing the Number of CT Pulmonary Angiograms.

    PubMed

    Drescher, Michael J; Fried, Jeremy; Brass, Ryan; Medoro, Amanda; Murphy, Timothy; Delgado, João

    2017-10-01

    Computerized decision support decreases the number of computed tomography pulmonary angiograms (CTPA) for pulmonary embolism (PE) ordered in emergency departments, but it is not always well accepted by emergency physicians. We studied a department-endorsed, evidence-based clinical protocol that included the PE rule-out criteria (PERC) rule, multi-modal education using principles of knowledge translation (KT), and clinical decision support embedded in our order entry system, to decrease the number of unnecessary CTPA ordered. We performed a historically controlled observational before-after study for one year pre- and post-implementation of a departmentally-endorsed protocol. We included patients > 18 in whom providers suspected PE and who did not have a contraindication to CTPA. Providers entered clinical information into a diagnostic pathway via computerized order entry. Prior to protocol implementation, we provided education to ordering providers. The primary outcome measure was the number of CTPA ordered per 1,000 visits one year before vs. after implementation. CTPA declined from 1,033 scans for 98,028 annual visits (10.53 per 1,000 patient visits (95% CI [9.9-11.2]) to 892 scans for 101,172 annual visits (8.81 per 1,000 patient visits (95% CI [8.3-9.4]) p<0.001. The absolute reduction in PACT ordered was 1.72 per 1,000 visits (a 16% reduction). Patient characteristics were similar for both periods. Knowledge translation clinical decision support using the PERC rule significantly reduced the number of CTPA ordered.

  9. Computerized clinical documentation system in the pediatric intensive care unit

    PubMed Central

    2001-01-01

    Background To determine whether a computerized clinical documentation system (CDS): 1) decreased time spent charting and increased time spent in patient care; 2) decreased medication errors; 3) improved clinical decision making; 4) improved quality of documentation; and/or 5) improved shift to shift nursing continuity. Methods Before and after implementation of CDS, a time study involving nursing care, medication delivery, and normalization of serum calcium and potassium values was performed. In addition, an evaluation of completeness of documentation and a clinician survey of shift to shift reporting were also completed. This was a modified one group, pretest-posttest design. Results With the CDS there was: improved legibility and completeness of documentation, data with better accessibility and accuracy, no change in time spent in direct patient care or charting by nursing staff. Incidental observations from the study included improved management functions of our nurse manager; improved JCAHO documentation compliance; timely access to clinical data (labs, vitals, etc); a decrease in time and resource use for audits; improved reimbursement because of the ability to reconstruct lost charts; limited human data entry by automatic data logging; eliminated costs of printing forms. CDS cost was reasonable. Conclusions When compared to a paper chart, the CDS provided a more legible, compete, and accessible patient record without affecting time spent in direct patient care. The availability of the CDS improved shift to shift reporting. Other observations showed that the CDS improved management capabilities; helped physicians deliver care; improved reimbursement; limited data entry errors; and reduced costs. PMID:11604105

  10. Designing Computerized Decision Support That Works for Clinicians and Families

    PubMed Central

    Fiks, Alexander G.

    2011-01-01

    Evidence-based decision-making is central to the practice of pediatrics. Clinical trials and other biomedical research provide a foundation for this process, and practice guidelines, drawing from their results, inform the optimal management of an increasing number of childhood health problems. However, many clinicians fail to adhere to guidelines. Clinical decision support delivered using health information technology, often in the form of electronic health records, provides a tool to deliver evidence-based information to the point of care and has the potential to overcome barriers to evidence-based practice. An increasing literature now informs how these systems should be designed and implemented to most effectively improve outcomes in pediatrics. Through the examples of computerized physician order entry, as well as the impact of alerts at the point of care on immunization rates, the delivery of evidence-based asthma care, and the follow-up of children with attention deficit hyperactivity disorder, the following review addresses strategies for success in using these tools. The following review argues that, as decision support evolves, the clinician should no longer be the sole target of information and alerts. Through the Internet and other technologies, families are increasingly seeking health information and gathering input to guide health decisions. By enlisting clinical decision support systems to deliver evidence-based information to both clinicians and families, help families express their preferences and goals, and connect families to the medical home, clinical decision support may ultimately be most effective in improving outcomes. PMID:21315295

  11. 45 CFR 307.15 - Approval of advance planning documents for computerized support enforcement systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... computerized support enforcement systems. 307.15 Section 307.15 Public Welfare Regulations Relating to Public... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES COMPUTERIZED SUPPORT ENFORCEMENT SYSTEMS § 307.15 Approval of advance planning documents for computerized support enforcement systems. (a...

  12. Arkansas' Curriculum Guide. Competency Based Computerized Accounting.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock. Div. of Vocational, Technical and Adult Education.

    This guide contains the essential parts of a total curriculum for a one-year secondary-level course in computerized accounting. Addressed in the individual sections of the guide are the following topics: the complete accounting cycle, computer operations for accounting, computerized accounting and general ledgers, computerized accounts payable,…

  13. A Mobile Computerized Decision Support System to Prevent Hypoglycemia in Hospitalized Patients With Type 2 Diabetes Mellitus

    PubMed Central

    Spat, Stephan; Donsa, Klaus; Beck, Peter; Höll, Bernhard; Mader, Julia K.; Schaupp, Lukas; Augustin, Thomas; Chiarugi, Franco; Lichtenegger, Katharina M.; Plank, Johannes; Pieber, Thomas R.

    2016-01-01

    Background: Diabetes management requires complex and interdisciplinary cooperation of health care professionals (HCPs). To support this complex process, IT-support is recommended by clinical guidelines. The aim of this article is to report on results from a clinical feasibility study testing the prototype of a mobile, tablet-based client-server system for computerized decision and workflow support (GlucoTab®) and to discuss its impact on hypoglycemia prevention. Methods: The system was tested in a monocentric, open, noncontrolled intervention study in 30 patients with type 2 diabetes mellitus (T2DM). The system supports HCPs in performing a basal-bolus insulin therapy. Diabetes therapy, adverse events, software errors and user feedback were documented. Safety, efficacy and user acceptance of the system were investigated. Results: Only 1.3% of blood glucose (BG) measurements were <70 mg/dl and only 2.6% were >300 mg/dl. The availability of the system (97.3%) and the rate of treatment activities documented with the system (>93.5%) were high. Only few suggestions from the system were overruled by the users (>95.7% adherence). Evaluation of the 3 anonymous questionnaires showed that confidence in the system increased over time. The majority of users believed that treatment errors could be prevented by using this system. Conclusions: Data from our feasibility study show a significant reduction of hypoglycemia by implementing a computerized system for workflow and decision support for diabetes management, compared to a paper-based process. The system was well accepted by HCPs, which is shown in the user acceptance analysis and that users adhered to the insulin dose suggestions made by the system. PMID:27810995

  14. Implementing an evidence-based computerized decision support system linked to electronic health records to improve care for cancer patients: the ONCO-CODES study protocol for a randomized controlled trial.

    PubMed

    Moja, Lorenzo; Passardi, Alessandro; Capobussi, Matteo; Banzi, Rita; Ruggiero, Francesca; Kwag, Koren; Liberati, Elisa Giulia; Mangia, Massimo; Kunnamo, Ilkka; Cinquini, Michela; Vespignani, Roberto; Colamartini, Americo; Di Iorio, Valentina; Massa, Ilaria; González-Lorenzo, Marien; Bertizzolo, Lorenzo; Nyberg, Peter; Grimshaw, Jeremy; Bonovas, Stefanos; Nanni, Oriana

    2016-11-25

    Computerized decision support systems (CDSSs) are computer programs that provide doctors with person-specific, actionable recommendations, or management options that are intelligently filtered or presented at appropriate times to enhance health care. CDSSs might be integrated with patient electronic health records (EHRs) and evidence-based knowledge. The Computerized DEcision Support in ONCOlogy (ONCO-CODES) trial is a pragmatic, parallel group, randomized controlled study with 1:1 allocation ratio. The trial is designed to evaluate the effectiveness on clinical practice and quality of care of a multi-specialty collection of patient-specific reminders generated by a CDSS in the IRCCS Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) hospital. We hypothesize that the intervention can increase clinician adherence to guidelines and, eventually, improve the quality of care offered to cancer patients. The primary outcome is the rate at which the issues reported by the reminders are resolved, aggregating specialty and primary care reminders. We will include all the patients admitted to hospital services. All analyses will follow the intention-to-treat principle. The results of our study will contribute to the current understanding of the effectiveness of CDSSs in cancer hospitals, thereby informing healthcare policy about the potential role of CDSS use. Furthermore, the study will inform whether CDSS may facilitate the integration of primary care in cancer settings, known to be usually limited. The increasing use of and familiarity with advanced technology among new generations of physicians may support integrated approaches to be tested in pragmatic studies determining the optimal interface between primary and oncology care. ClinicalTrials.gov, NCT02645357.

  15. Characteristic clinical features of Aspergillus appendicitis: Case report and literature review.

    PubMed

    Gjeorgjievski, Mihajlo; Amin, Mitual B; Cappell, Mitchell S

    2015-11-28

    This work aims to facilitate diagnosing Aspergillus appendicitis, which can be missed clinically due to its rarity, by proposing a clinical pentad for Aspergillus appendicitis based on literature review and one new case. The currently reported case of pathologically-proven Aspergillus appendicitis was identified by computerized search of pathology database at William Beaumont Hospital, 1999-2014. Prior cases were identified by computerized literature search. Among 10980 pathology reports of pathologically-proven appendicitis, one case of Aspergillus appendicitis was identified (rate = 0.01%). A young boy with profound neutropenia, recent chemotherapy, and acute myelogenous leukemia presented with right lower quadrant pain, pyrexia, and generalized malaise. Abdominal computed tomography scan showed a thickened appendiceal wall and periappendiceal inflammation, suggesting appendicitis. Emergent laparotomy showed an inflamed, thickened appendix, which was resected. The patient did poorly postoperatively with low-grade-fevers while receiving antibacterial therapy, but rapidly improved after initiating amphotericin therapy. Microscopic examination of a silver stain of the appendectomy specimen revealed fungi with characteristic Aspergillus morphology, findings confirmed by immunohistochemistry. Primary Aspergillus appendicitis is exceptionally rare, with only 3 previously reported cases. All three cases presented with (1)-neutropenia, (2)-recent chemotherapy, (3)-acute leukemia, and (4)-suspected appendicitis; (5)-the two prior cases initially treated with antibacterial therapy, fared poorly before instituting anti-Aspergillus therapy. The current patient satisfied all these five criteria. Based on these four cases, a clinical pentad is proposed for Aspergillus appendicitis: clinically-suspected appendicitis, neutropenia, recent chemotherapy, acute leukemia, and poor clinical response if treated solely by antibacterial/anti-candidial therapy. Patients presenting with this proposed pentad may benefit from testing for Aspergillus infection by silver-stains/immunohistochemistry and considering empirical anti-Aspergillus therapy pending a tissue diagnosis.

  16. Tomographic imaging of subducted lithosphere below northwest Pacific island arcs

    USGS Publications Warehouse

    Van Der Hilst, R.; Engdahl, R.; Spakman, W.; Nolet, G.

    1991-01-01

    The seismic tomography problem does not have a unique solution, and published tomographic images have been equivocal with regard to the deep structure of subducting slabs. An improved tomographic method, using a more realistic background Earth model and surf ace-reflected as well as direct seismic phases, shows that slabs beneath the Japan and Izu Bonin island arcs are deflected at the boundary between upper and lower mantle, whereas those beneath the northern Kuril and Mariana arcs sink into the lower mantle.

  17. 3D "spectracoustic" system: a modular, tomographic, spectroscopic mapping imaging, non-invasive, diagnostic system for detection of small starting developing tumors like melanoma

    NASA Astrophysics Data System (ADS)

    Karagiannis, Georgios

    2017-03-01

    This work led to a new method named 3D spectracoustic tomographic mapping imaging. The current and the future work is related to the fabrication of a combined acoustic microscopy transducer and infrared illumination probe permitting the simultaneous acquisition of the spectroscopic and the tomographic information. This probe provides with the capability of high fidelity and precision registered information from the combined modalities named spectracoustic information.

  18. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    DTIC Science & Technology

    2016-04-28

    Single- shot , volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...us.af.mil Abstract: Single- shot , tomographic imaging of the three-dimensional concentration field is demonstrated in a turbulent gaseous free jet in co-flow...2001). 6. K. M. Tacina and W. J. A. Dahm, “Effects of heat release on turbulent shear flows, Part 1. A general equivalence principle for non-buoyant

  19. Tomographic diffractive microscopy with agile illuminations for imaging targets in a noisy background.

    PubMed

    Zhang, T; Godavarthi, C; Chaumet, P C; Maire, G; Giovannini, H; Talneau, A; Prada, C; Sentenac, A; Belkebir, K

    2015-02-15

    Tomographic diffractive microscopy is a marker-free optical digital imaging technique in which three-dimensional samples are reconstructed from a set of holograms recorded under different angles of incidence. We show experimentally that, by processing the holograms with singular value decomposition, it is possible to image objects in a noisy background that are invisible with classical wide-field microscopy and conventional tomographic reconstruction procedure. The targets can be further characterized with a selective quantitative inversion.

  20. Multidetector computed tomographic pulmonary angiography in patients with a high clinical probability of pulmonary embolism.

    PubMed

    Moores, L; Kline, J; Portillo, A K; Resano, S; Vicente, A; Arrieta, P; Corres, J; Tapson, V; Yusen, R D; Jiménez, D

    2016-01-01

    ESSENTIALS: When high probability of pulmonary embolism (PE), sensitivity of computed tomography (CT) is unclear. We investigated the sensitivity of multidetector CT among 134 patients with a high probability of PE. A normal CT alone may not safely exclude PE in patients with a high clinical pretest probability. In patients with no clear alternative diagnosis after CTPA, further testing should be strongly considered. Whether patients with a negative multidetector computed tomographic pulmonary angiography (CTPA) result and a high clinical pretest probability of pulmonary embolism (PE) should be further investigated is controversial. This was a prospective investigation of the sensitivity of multidetector CTPA among patients with a priori clinical assessment of a high probability of PE according to the Wells criteria. Among patients with a negative CTPA result, the diagnosis of PE required at least one of the following conditions: ventilation/perfusion lung scan showing a high probability of PE in a patient with no history of PE, abnormal findings on venous ultrasonography in a patient without previous deep vein thrombosis at that site, or the occurrence of venous thromboembolism (VTE) in a 3-month follow-up period after anticoagulation was withheld because of a negative multidetector CTPA result. We identified 498 patients with a priori clinical assessment of a high probability of PE and a completed CTPA study. CTPA excluded PE in 134 patients; in these patients, the pooled incidence of VTE was 5.2% (seven of 134 patients; 95% confidence interval [CI] 1.5-9.0). Five patients had VTEs that were confirmed by an additional imaging test despite a negative CTPA result (five of 48 patients; 10.4%; 95% CI 1.8-19.1), and two patients had objectively confirmed VTEs that occurred during clinical follow-up of at least 3 months (two of 86 patients; 2.3%; 95% CI 0-5.5). None of the patients had a fatal PE during follow-up. A normal multidetector CTPA result alone may not safely exclude PE in patients with a high clinical pretest probability. © 2015 International Society on Thrombosis and Haemostasis.

  1. DoctorEye: A clinically driven multifunctional platform, for accurate processing of tumors in medical images.

    PubMed

    Skounakis, Emmanouil; Farmaki, Christina; Sakkalis, Vangelis; Roniotis, Alexandros; Banitsas, Konstantinos; Graf, Norbert; Marias, Konstantinos

    2010-01-01

    This paper presents a novel, open access interactive platform for 3D medical image analysis, simulation and visualization, focusing in oncology images. The platform was developed through constant interaction and feedback from expert clinicians integrating a thorough analysis of their requirements while having an ultimate goal of assisting in accurately delineating tumors. It allows clinicians not only to work with a large number of 3D tomographic datasets but also to efficiently annotate multiple regions of interest in the same session. Manual and semi-automatic segmentation techniques combined with integrated correction tools assist in the quick and refined delineation of tumors while different users can add different components related to oncology such as tumor growth and simulation algorithms for improving therapy planning. The platform has been tested by different users and over large number of heterogeneous tomographic datasets to ensure stability, usability, extensibility and robustness with promising results. the platform, a manual and tutorial videos are available at: http://biomodeling.ics.forth.gr. it is free to use under the GNU General Public License.

  2. Inflammatory Myofibroblastic Tumor Mimicking Apical Periodontitis.

    PubMed

    Adachi, Makoto; Kiho, Kazuki; Sekine, Genta; Ohta, Takahisa; Matsubara, Makoto; Yoshida, Takakazu; Katsumata, Akitoshi; Tanuma, Jun-ichi; Sumitomo, Shinichiro

    2015-12-01

    Inflammatory myofibroblastic tumors (IMTs) are rare. IMTs of the head and neck occur in all age groups, from neonates to old age, with the highest incidence occurring in childhood and early adulthood. An IMT has been defined as a histologically distinctive lesion of uncertain behavior. This article describes an unusual case of IMT mimicking apical periodontitis in the mandible of a 42-year-old man. At first presentation, the patient showed spontaneous pain and percussion pain at teeth #28 to 30, which continued after initial endodontic treatment. Panoramic radiography revealed a radiolucent lesion at the site. Cone-beam computed tomographic imaging showed osteolytic lesions, suggesting an aggressive neoplasm requiring incisional biopsy. Histopathological examination indicated an IMT. The lesion was removed en bloc under general anesthesia, and the patient manifested no clinical evidence of recurrence for 24 months. Lesions of nonendodontic origin should be included in the differential diagnosis of apical periodontitis. Every available diagnostic tool should be used to confirm the diagnosis. Cone-beam computed tomographic imaging is very helpful for differential diagnosis in IMTs mimicking apical periodontitis. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Perforating internal root resorption repaired with mineral trioxide aggregate caused complete resolution of odontogenic sinus mucositis: a case report.

    PubMed

    Bendyk-Szeffer, Maja; Łagocka, Ryta; Trusewicz, Matylda; Lipski, Mariusz; Buczkowska-Radlińska, Jadwiga

    2015-02-01

    An extensive perforating internal root resorption accompanied by apical periodontitis and odontogenic sinus mucositis was detected on preoperative cone-beam computed tomographic scans in a first maxillary molar. After the chemomechanical debridement of the root canals, calcium hydroxide was placed as a temporary dressing for 7 days. Mineral trioxide aggregate was used to fill the perforation site with the aid of a surgical microscope. At the next visit, the root with the resorption defect was filled with warm vertical compaction of gutta-percha. A control cone-beam computed tomographic scan acquired 6 months after the endodontic treatment revealed complete resolution of the sinus retention cyst. Moreover, the patient's frequent otolaryngologic disturbances ceased. The tooth was functional with satisfactory clinical and radiographic results after 12 months. Based on the results of this case, successful repair of an extensive, perforating internal resorption with mineral trioxide aggregate may lead to complete resolution of apical periodontitis and maxillary sinus retention cyst. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Computerized Adaptive Personality Testing: A Review and Illustration With the MMPI-2 Computerized Adaptive Version.

    ERIC Educational Resources Information Center

    Forbey, Johnathan D.; Ben-Porath, Yossef S.

    2007-01-01

    Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…

  5. A Randomized Controlled Trial of the "Cool Teens" CD-ROM Computerized Program for Adolescent Anxiety

    ERIC Educational Resources Information Center

    Wuthrich, Viviana M.; Rapee, Ronald M.; Cunningham, Michael J.; Lyneham, Heidi J.; Hudson, Jennifer L.; Schniering, Carolyn A.

    2012-01-01

    Objective: Computerized cognitive behavioral interventions for anxiety disorders in adults have been shown to be efficacious, but limited data are available on the use of computerized interventions with young persons. Adolescents in particular are difficult to engage in treatment and may be especially suited to computerized technologies. This…

  6. Computerized planning of prostate cryosurgery using variable cryoprobe insertion depth.

    PubMed

    Rossi, Michael R; Tanaka, Daigo; Shimada, Kenji; Rabin, Yoed

    2010-02-01

    The current study presents a computerized planning scheme for prostate cryosurgery using a variable insertion depth strategy. This study is a part of an ongoing effort to develop computerized tools for cryosurgery. Based on typical clinical practices, previous automated planning schemes have required that all cryoprobes be aligned at a single insertion depth. The current study investigates the benefit of removing this constraint, in comparison with results based on uniform insertion depth planning as well as the so-called "pullback procedure". Planning is based on the so-called "bubble-packing method", and its quality is evaluated with bioheat transfer simulations. This study is based on five 3D prostate models, reconstructed from ultrasound imaging, and cryoprobe active length in the range of 15-35 mm. The variable insertion depth technique is found to consistently provide superior results when compared to the other placement methods. Furthermore, it is shown that both the optimal active length and the optimal number of cryoprobes vary among prostate models, based on the size and shape of the target region. Due to its low computational cost, the new scheme can be used to determine the optimal cryoprobe layout for a given prostate model in real time. Copyright 2008 Elsevier Inc. All rights reserved.

  7. Partial dependence of breast tumor malignancy on ultrasound image features derived from boosted trees

    NASA Astrophysics Data System (ADS)

    Yang, Wei; Zhang, Su; Li, Wenying; Chen, Yaqing; Lu, Hongtao; Chen, Wufan; Chen, Yazhu

    2010-04-01

    Various computerized features extracted from breast ultrasound images are useful in assessing the malignancy of breast tumors. However, the underlying relationship between the computerized features and tumor malignancy may not be linear in nature. We use the decision tree ensemble trained by the cost-sensitive boosting algorithm to approximate the target function for malignancy assessment and to reflect this relationship qualitatively. Partial dependence plots are employed to explore and visualize the effect of features on the output of the decision tree ensemble. In the experiments, 31 image features are extracted to quantify the sonographic characteristics of breast tumors. Patient age is used as an external feature because of its high clinical importance. The area under the receiver-operating characteristic curve of the tree ensembles can reach 0.95 with sensitivity of 0.95 (61/64) at the associated specificity 0.74 (77/104). The partial dependence plots of the four most important features are demonstrated to show the influence of the features on malignancy, and they are in accord with the empirical observations. The results can provide visual and qualitative references on the computerized image features for physicians, and can be useful for enhancing the interpretability of computer-aided diagnosis systems for breast ultrasound.

  8. Reducing depressive intrusions via a computerized cognitive bias modification of appraisals task: developing a cognitive vaccine.

    PubMed

    Lang, Tamara J; Moulds, Michelle L; Holmes, Emily A

    2009-02-01

    A feature of depression is the distressing experience of intrusive, negative memories. The maladaptive appraisals of such intrusions have been associated with symptom persistence. This study aimed to experimentally manipulate appraisals about depressive intrusions via a novel computerized cognitive bias modification (CBM) of appraisals paradigm, and to test the impact on depressive intrusion frequency for a standardized event (a depressive film). Forty-eight participants were randomly assigned to either a session of positive or negative CBM. Participants then watched a depressing film (including scenes of bereavement and bullying) and subsequently monitored the occurrence of depressive intrusions related to the film in a diary for one week. At one-week follow-up, participants completed additional measures of intrusions--the Impact of Event Scale (IES) and an intrusion provocation task. As predicted, compared to the negative condition, participants who underwent positive CBM showed a more positive appraisal bias. Further, one week later, positive CBM participants reported fewer intrusions of the film and had lower IES scores. Our findings demonstrate that it is possible to manipulate maladaptive appraisals about depressive intrusions via a computerized CBM task. Further, this effect transfers to reducing intrusive symptomatology related to a standardized event (a depressive film) over one week, suggesting novel clinical implications.

  9. A prototype of a computerized patient record.

    PubMed

    Adelhard, K; Eckel, R; Hölzel, D; Tretter, W

    1995-01-01

    Computerized medical record systems (CPRS) should present user and problem oriented views of the patient file. Problem lists, clinical course, medication profiles and results of examinations have to be recorded in a computerized patient record. Patient review screens should give a synopsis of the patient data to inform whenever the patient record is opened. Several different types of data have to be stored in a patient record. Qualitative and quantitative measurements, narratives and images are such examples. Therefore, a CPR must also be able to handle these different data types. New methods and concepts appear frequently in medicine. Thus a CPRS must be flexible enough to cope with coming demands. We developed a prototype of a computer based patient record with a graphical user interface on a SUN workstation. The basis of the system are a dynamic data dictionary, an interpreter language and a large set of basic functions. This approach gives optimal flexibility to the system. A lot of different data types are already supported. Extensions are easily possible. There is also almost no limit concerning the number of medical concepts that can be handled by our prototype. Several applications were built on this platform. Some of them are presented to exemplify the patient and problem oriented handling of the CPR.

  10. Computerized techniques pave the way for drug-drug interaction prediction and interpretation

    PubMed Central

    Safdari, Reza; Ferdousi, Reza; Aziziheris, Kamal; Niakan-Kalhori, Sharareh R.; Omidi, Yadollah

    2016-01-01

    Introduction: Health care industry also patients penalized by medical errors that are inevitable but highly preventable. Vast majority of medical errors are related to adverse drug reactions, while drug-drug interactions (DDIs) are the main cause of adverse drug reactions (ADRs). DDIs and ADRs have mainly been reported by haphazard case studies. Experimental in vivo and in vitro researches also reveals DDI pairs. Laboratory and experimental researches are valuable but also expensive and in some cases researchers may suffer from limitations. Methods: In the current investigation, the latest published works were studied to analyze the trend and pattern of the DDI modelling and the impacts of machine learning methods. Applications of computerized techniques were also investigated for the prediction and interpretation of DDIs. Results: Computerized data-mining in pharmaceutical sciences and related databases provide new key transformative paradigms that can revolutionize the treatment of diseases and hence medical care. Given that various aspects of drug discovery and pharmacotherapy are closely related to the clinical and molecular/biological information, the scientifically sound databases (e.g., DDIs, ADRs) can be of importance for the success of pharmacotherapy modalities. Conclusion: A better understanding of DDIs not only provides a robust means for designing more effective medicines but also grantees patient safety. PMID:27525223

  11. [The importance of neurological examinations in the age of the technological revolution].

    PubMed

    Berbel-García, A; González-Spínola, J; Martínez-Salio, A; Porta-Etessam, J; Pérez-Martínez, D A; de Toledo, M; Sáiz-Díaz, R A

    Neurologic practice and care have been modified in many important ways during the past ten years, to adapt to the explosion of new information and new technology. Students, residents and practicing physicians have been continuing programs to a model that focuses almost exclusively on the applications to neurologic disorders of the new knowledge obtained from biomedical research. On the other hand high demand for outpatient neurologic care prevents adequate patient's evaluation. Case 1: 65 years old female. Occipital headache diagnosed of tensional origin (normal computerized tomography). Two months later is re-evaluated due to intractable pain and hypoglossal lesion. An amplified computerized tomography revealed a occipital condyle metastasis. Case 2: 21 years old female. Clinical suspicion of demyelinating disease due to repeated facial paresis and sensitive disorder. General exploration and computerized tomography revealed temporo-mandibular joint. Case 3: 60 years old female. Valuation of anticoagulant therapy due to repeated transient ischemic attacks. She suffered from peripheral facial palsy related to auditory cholesteatoma. Neurologic education is nowadays orientated to new technologies. On the other hand, excessive demand prevents adequate valuation and a minute exploration is substituted by complementary evaluations. These situations generate diagnostic mistakes or iatrogenic. It would be important a consideration of the neurologic education profiles and fulfillment of consultations time recommendations for outpatients care.

  12. Improving the utility of the fine motor skills subscale of the comprehensive developmental inventory for infants and toddlers: a computerized adaptive test.

    PubMed

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Chou, Willy; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2017-07-27

    This study aimed at improving the utility of the fine motor subscale of the comprehensive developmental inventory for infants and toddlers (CDIIT) by developing a computerized adaptive test of fine motor skills. We built an item bank for the computerized adaptive test of fine motor skills using the fine motor subscale of the CDIIT items fitting the Rasch model. We also examined the psychometric properties and efficiency of the computerized adaptive test of fine motor skills with simulated computerized adaptive tests. Data from 1742 children with suspected developmental delays were retrieved. The mean scores of the fine motor subscale of the CDIIT increased along with age groups (mean scores = 1.36-36.97). The computerized adaptive test of fine motor skills contains 31 items meeting the Rasch model's assumptions (infit mean square = 0.57-1.21, outfit mean square = 0.11-1.17). For children of 6-71 months, the computerized adaptive test of fine motor skills had high Rasch person reliability (average reliability >0.90), high concurrent validity (rs = 0.67-0.99), adequate to excellent diagnostic accuracy (area under receiver operating characteristic = 0.71-1.00), and large responsiveness (effect size = 1.05-3.93). The computerized adaptive test of fine motor skills used 48-84% fewer items than the fine motor subscale of the CDIIT. The computerized adaptive test of fine motor skills used fewer items for assessment but was as reliable and valid as the fine motor subscale of the CDIIT. Implications for Rehabilitation We developed a computerized adaptive test based on the comprehensive developmental inventory for infants and toddlers (CDIIT) for assessing fine motor skills. The computerized adaptive test has been shown to be efficient because it uses fewer items than the original measure and automatically presents the results right after the test is completed. The computerized adaptive test is as reliable and valid as the CDIIT.

  13. Association of Inter-arm Blood Pressure Difference with Asymptomatic Intracranial and Extracranial Arterial Stenosis in Hypertension Patients.

    PubMed

    Wang, Yan; Zhang, Jin; Qian, Yuesheng; Tang, Xiaofeng; Ling, Huawei; Chen, Kemin; Li, Yan; Gao, Pingjin; Zhu, Dingliang

    2016-07-14

    Inter-arm blood pressure (BP) difference has been associated with ischemic stroke. Local atherosclerosis of stroke differ among vulnerable individuals, whereas intracranial arterial stenosis (ICAS) is more frequently affected Asians, and extracranial arterial stenosis (ECAS) is more prevalent among whites. We hereby sought to explore the association of inter-arm BP difference with ICAS and ECAS in stroke-free hypertensive patients in Chinese population. All the 885 subjects were evaluated of ICAS and ECAS through computerized tomographic angiography. Both arm BP was measured simultaneously by Vascular Profiler-1000 device. In the continuous study, ICAS was significantly associated with age, male, average brachial SBP, diabetes, anti-hypertensive treatment and inter-arm DBP difference. ECAS was associated with age, inter-arm SBP and LDL. In the categorical study, subjects with the top quartile of inter-arm DBP difference (≥4 mmHg) showed significantly higher risk of ICAS (OR = 2.109; 95% CI, 1.24-3.587). And the participants with the top quartile of inter-arm SBP difference (≥6 mmHg) showed significantly higher risk of ECAS (OR = 2.288; 95% CI, 1.309-3.998). In conclusion, we reported a diverse association of inter-arm SBP/DBP difference with the ICAS/ECAS. Inter-arm DBP difference might be the early symbol of ICAS in Chinese population, which need further verification in long-term cohort study.

  14. Regional model-based computerized ionospheric tomography using GPS measurements: IONOLAB-CIT

    NASA Astrophysics Data System (ADS)

    Tuna, Hakan; Arikan, Orhan; Arikan, Feza

    2015-10-01

    Three-dimensional imaging of the electron density distribution in the ionosphere is a crucial task for investigating the ionospheric effects. Dual-frequency Global Positioning System (GPS) satellite signals can be used to estimate the slant total electron content (STEC) along the propagation path between a GPS satellite and ground-based receiver station. However, the estimated GPS-STEC is very sparse and highly nonuniformly distributed for obtaining reliable 3-D electron density distributions derived from the measurements alone. Standard tomographic reconstruction techniques are not accurate or reliable enough to represent the full complexity of variable ionosphere. On the other hand, model-based electron density distributions are produced according to the general trends of ionosphere, and these distributions do not agree with measurements, especially for geomagnetically active hours. In this study, a regional 3-D electron density distribution reconstruction method, namely, IONOLAB-CIT, is proposed to assimilate GPS-STEC into physical ionospheric models. The proposed method is based on an iterative optimization framework that tracks the deviations from the ionospheric model in terms of F2 layer critical frequency and maximum ionization height resulting from the comparison of International Reference Ionosphere extended to Plasmasphere (IRI-Plas) model-generated STEC and GPS-STEC. The suggested tomography algorithm is applied successfully for the reconstruction of electron density profiles over Turkey, during quiet and disturbed hours of ionosphere using Turkish National Permanent GPS Network.

  15. Compton imaging tomography for nondestructive evaluation of large multilayer aircraft components and structures

    NASA Astrophysics Data System (ADS)

    Romanov, Volodymyr; Grubsky, Victor; Zahiri, Feraidoon

    2017-02-01

    We present a novel NDT/NDE tool for non-contact, single-sided 3D inspection of aerospace components, based on Compton Imaging Tomography (CIT) technique, which is applicable to large, non-uniform, and/or multilayer structures made of composites or lightweight metals. CIT is based on the registration of Compton-scattered X-rays, and permits the reconstruction of the full 3D (tomographic) image of the inspected objects. Unlike conventional computerized tomography (CT), CIT requires only single-sided access to objects, and therefore can be applied to large structures without their disassembly. The developed tool provides accurate detection, identification, and precise 3D localizations and measurements of any possible internal and surface defects (corrosions, cracks, voids, delaminations, porosity, and inclusions), and also disbonds, core and skin defects, and intrusion of foreign fluids (e.g., fresh and salt water, oil) inside of honeycomb sandwich structures. The NDE capabilities of the system were successfully demonstrated on various aerospace structure samples provided by several major aerospace companies. Such a CIT-based tool can detect and localize individual internal defects with dimensions about 1-2 mm3, and honeycomb disbond defects less than 6 mm by 6 mm area with the variations in the thickness of the adhesive by 100 m. Current maximum scanning speed of aircraft/spacecraft structures is about 5-8 min/ft2 (50-80 min/m2).

  16. Superficial Palmar Arch Aneurysm after Carpal Tunnel Decompression, a Rare Complication: A Case Report

    PubMed Central

    Gull, S.; Spence, R. A. J.; Loan, W.

    2011-01-01

    False aneurysms of the palmar arteries are rare. They are usually associated with traumatic injuries to the hand vasculature. We present a case of superficial palmar arch aneurysm (SPAA), complicating carpal tunnel decompression which presented as a pulsatile mass at the site of previous surgery. Initial diagnosis was made on clinical examination and confirmed on doppler ultrasound (US) and computed tomographic angiography (CTA). The feeding vessel of the aneurysm was subsequently occluded using coil embolization. PMID:21547251

  17. Corkscrew basilar artery as an incidental finding on neuroimaging.

    PubMed

    Moser, Franklin G; Sarnat, Harvey B; Maya, Marcel M; Menkes, John H

    2007-11-01

    We report on an incidental finding of a markedly tortuous basilar artery in a 6-year-old child. The child underwent a computed tomography scan for minor head trauma, and a basilar artery abnormality was discovered, i.e., a markedly tortuous basilar artery without any other congenital anomalies or syndromes. After an exhaustive workup including computed tomography, magnetic resonance imaging, magnetic resonance angiography, computed tomographic angiography, and genetic tests for associated genetic syndromes, no intervention was deemed necessary. The embryonic etiology and clinical implications are discussed.

  18. [Computerized clinical protocol for occlusion].

    PubMed

    Salsench, J; Ferrer, J; Nogueras, J

    1988-11-01

    In making a protocol it is necessary that all members of the team who are going to collect information have the same unity of criterion about the different variables that compose it. The drawing up of this document is as much or more necessary than the protocol itself. In this work we all data collected in the protocol and we give the explanations of each concept.

  19. Osteochondrosis of the inferior pole of the scapula (Roca disease).

    PubMed

    Skaf, Abdalla; Taneja, Atul K

    2014-03-01

    We report a rare case of osteochondrosis of the inferior pole of the scapula in a 14-year-old boy, an amateur swimmer, that was diagnosed by a combination of clinical and imaging findings. Also known as Roca disease, this is the first article to report this entity in the English literature and demonstrates its computerized tomography and MRI features.

  20. [Use of the computer as a tool for the implementation of the nursing process--the experience of the Sâo Paulo/UNIFESP].

    PubMed

    de Barros, Alba Lúcia; Fakih, Flávio Trevisani; Michel, Jeanne Liliane

    2002-01-01

    This article reports the pathway used to build a prototype of a computer nurse's clinical decision making support system, using NANDA, NIC and NOC classifications, as an auxiliary tool in the insertion of nursing data in the computerized patient record of Hospital São Paulo/UNIFESP.

  1. Using Computerized Games to Teach Face Recognition Skills to Children with Autism Spectrum Disorder: The "Let's Face It!" Program

    ERIC Educational Resources Information Center

    Tanaka, James W.; Wolf, Julie M.; Klaiman, Cheryl; Koenig, Kathleen; Cockburn, Jeffrey; Herlihy, Lauren; Brown, Carla; Stahl, Sherin; Kaiser, Martha D.; Schultz, Robert T.

    2010-01-01

    Background: An emerging body of evidence indicates that relative to typically developing children, children with autism are selectively impaired in their ability to recognize facial identity. A critical question is whether face recognition skills can be enhanced through a direct training intervention. Methods: In a randomized clinical trial,…

  2. ISYS-MD: A Surgeon's Influence on System Design

    PubMed Central

    Cavaye, Graham

    1982-01-01

    ISYS-MD, the Integrated SYStem in MUMPS for MD's, is a new design and a completely re-written system for a computerized medical record. It possesses the functionality of COSTAR combined with a comprehensive accountancy system. In addition, various ideas have been incorporated from the author's extensive experience in medical practice, making the system very practical in a clinical environment.

  3. Optimal joule heating of the subsurface

    DOEpatents

    Berryman, J.G.; Daily, W.D.

    1994-07-05

    A method for simultaneously heating the subsurface and imaging the effects of the heating is disclosed. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.

  4. Lamb-Wave-Based Tomographic Imaging Techniques for Hole-Edge Corrosion Monitoring in Plate Structures

    PubMed Central

    Wang, Dengjiang; Zhang, Weifang; Wang, Xiangyu; Sun, Bo

    2016-01-01

    This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs) was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART) method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately. PMID:28774041

  5. Computerized Dental Injection Fear Treatment

    PubMed Central

    Heaton, L.J.; Leroux, B.G.; Ruff, P.A.; Coldwell, S.E.

    2013-01-01

    One in four adults reports a clinically significant fear of dental injections, leading many to avoid dental care. While systematic desensitization is the most common therapeutic method for treating specific phobias such as fear of dental injections, lack of access to trained therapists, as well as dentists’ lack of training and time in providing such a therapy, means that most fearful individuals are not able to receive the therapy needed to be able to receive necessary dental treatment. Computer Assisted Relaxation Learning (CARL) is a self-paced computerized treatment based on systematic desensitization for dental injection fear. This multicenter, block-randomized, dentist-blind, parallel-group study conducted in 8 sites in the United States compared CARL with an informational pamphlet in reducing fear of dental injections. Participants completing CARL reported significantly greater reduction in self-reported general and injection-specific dental anxiety measures compared with control individuals (p < .001). Twice as many CARL participants (35.3%) as controls (17.6%) opted to receive a dental injection after the intervention, although this was not statistically significant. CARL, therefore, led to significant changes in self-reported fear in study participants, but no significant differences in the proportion of participants having a dental injection (ClinicalTrials.gov, NCT00609648). PMID:23690352

  6. Application of computerized exercise ECG digitization. Interpretation in large clinical trials.

    PubMed

    Caralis, D G; Shaw, L; Bilgere, B; Younis, L; Stocke, K; Wiens, R D; Chaitman, B R

    1992-04-01

    The authors report on a semiautomated program that incorporates both visual identification of fiducial points and digital determination of the ST-segment at 60 ms and 80 ms from the J point, ST slope, changes in R wave, and baseline drift. The off-line program can enhance the accuracy of detecting electrocardiographic (ECG) changes, as well as reproducibility of the exercise and postexercise ECG, as a marker of myocardial ischemia. The analysis program is written in Microsoft QuickBASIC 2.0 for an IBM personal computer interfaced to a Summagraphics mm1201 microgrid II digitizer. The program consists of the following components: (1) alphanumeric data entry, (2) ECG wave form digitization, (2) calculation of test results, (4) physician overread, and (5) editor function for remeasurements. This computerized exercise ECG digitization-interpretation program is accurate and reproducible for the quantitative assessment of ST changes and requires minimal time allotment for physician overread. The program is suitable for analysis and interpretation of large volumes of exercise tests in multicenter clinical trials and is currently utilized in the TIMI II, TIMI III, and BARI studies sponsored by the National Institutes of Health.

  7. Challenges and opportunities for genomic developmental neuropsychology: examples from the Penn-Drexel collaborative battery.

    PubMed

    Gur, Ruben C; Irani, Farzin; Seligman, Sarah; Calkins, Monica E; Richard, Jan; Gur, Raquel E

    2011-08-01

    Genomics has been revolutionizing medicine over the past decade by offering mechanistic insights into disease processes and engendering the age of "individualized medicine." Because of the sheer number of measures generated by gene sequencing methods, genomics requires "Big Science" where large datasets on genes are analyzed in reference to electronic medical record data. This revolution has largely bypassed the behavioral neurosciences, mainly because of the paucity of behavioral data in medical records and the labor-intensity of available neuropsychological assessment methods. We describe the development and implementation of an efficient neuroscience-based computerized battery, coupled with a computerized clinical assessment procedure. This assessment package has been applied to a genomic study of 10,000 children aged 8-21, of whom 1000 also undergo neuroimaging. Results from the first 3000 participants indicate sensitivity to neurodevelopmental trajectories. Sex differences were evident, with females outperforming males in memory and social cognition domains, while for spatial processing males were more accurate and faster, and they were faster on simple motor tasks. The study illustrates what will hopefully become a major component of the work of clinical and research neuropsychologists as invaluable participants in the dawning age of Big Science neuropsychological genomics.

  8. F-18 fluorodeoxyglucose: Its potential in differentiating between stress fracture and neoplasia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paul, R.; Ahonen, A.; Virtama, P.

    1989-12-01

    F-18 fluorodeoxyglucose (FDG) accumulates into regions of enhanced glucose uptake and metabolism such as the brain, heart, and malignant tumors. The clinical usefulness of this positron-emitting radiopharmaceutical is illustrated in a case where the clinical picture and CT indicated a malignant bone lesion in the clavicle. Histologically a stress fracture was found secondary to chronic strain on the clavicle. On follow-up the lesion's course was benign. Planar imaging with F-18 FDG was performed twice during follow-up, and on both occasions there was no accumulation of radioactivity over the suspicious area, indicating normal glucose consumption. This case demonstrates the differential diagnosticmore » potential of F-18 FDG and shows that clinically useful information may be obtained without a position emission tomograph.« less

  9. Views of general practitioners on the use of STOPP&START in primary care: a qualitative study.

    PubMed

    Dalleur, O; Feron, J-M; Spinewine, A

    2014-08-01

    STOPP (Screening Tool of Older Person's Prescriptions) and START (Screening Tool to Alert Doctors to Right Treatment) criteria aim at detecting potentially inappropriate prescribing in older people. The objective was to explore general practitioners' (GPs) perceptions regarding the use of the STOPP&START tool in their practice. We conducted three focus groups which were conveniently sampled. Vignettes with clinical cases were provided for discussion as well as a full version of the STOPP&START tool. Knowledge, strengths and weaknesses of the tool and its implementation were discussed. Two researchers independently performed content analysis, classifying quotes and creating new categories for emerging themes. Discussions highlighted incentives (e.g. systematic procedure for medication review) and barriers (e.g. time-consuming application) influencing the use of STOPP&START in primary care. Usefulness, comprehensiveness, and relevance of the tool were also questioned. Another important category emerging from the content analysis was the projected use of the tool. The GPs imagined key elements for the implementation in daily practice: computerized clinical decision support system, education, and multidisciplinary collaborations, especially at care transitions and in nursing homes. Despite variables views on the usefulness, comprehensiveness, and relevance of STOPP&START, GPs suggest the implementation of this tool in primary care within computerized clinical decision support systems, through education, and used as part of multidisciplinary collaborations.

  10. Clinical utility of family history for cancer screening and referral in primary care: a report from the Family Healthware Impact Trial.

    PubMed

    Rubinstein, Wendy S; Acheson, Louise S; O'Neill, Suzanne M; Ruffin, Mack T; Wang, Catharine; Beaumont, Jennifer L; Rothrock, Nan

    2011-11-01

    To assess the effectiveness of computerized familial risk assessment and tailored messages for identifying individuals for targeted cancer prevention strategies and motivating behavior change. We conducted a randomized clinical trial in primary care patients aged 35-65 years using Family Healthware, a self-administered, internet-based tool that collects family history for six common diseases including breast cancer, colon cancer, and ovarian cancer, stratifies risk into three tiers, and provides tailored prevention messages. Cancer screening adherence and consultation were measured at baseline and 6-month follow-up. Of 3283 participants, 34% were at strong or moderate risk of at least one of the cancers. Family Healthware identified additional participants for whom earlier screening (colon cancer, 4.4%; breast cancer, women ages: 35-39 years, 9%) or genetic assessment (colon cancer, 2.5%; breast cancer, 10%; and ovarian cancer, 4%) may be indicated. Fewer than half were already adherent with risk-based screening. Screening adherence improved for all risk categories with no difference between intervention and control groups. Consultation with specialists did not differ between groups. Family Healthware identified patients for intensified cancer prevention. Engagement of clinicians and patients, integration with clinical decision support, and inclusion of nonfamilial risk factors may be necessary to achieve the full potential of computerized risk assessment.

  11. Use of Flowchart for Automation of Clinical Protocols in mHealth.

    PubMed

    Dias, Karine Nóra; Welfer, Daniel; Cordeiro d'Ornellas, Marcos; Pereira Haygert, Carlos Jesus; Dotto, Gustavo Nogara

    2017-01-01

    For healthcare professionals to use mobile applications we need someone who knows software development, provide them. In healthcare institutions, health professionals use clinical protocols to govern care, and sometimes these documents are computerized through mobile applications to assist them. This work aims to present a proposal of an application of flow as a way of describing clinical protocols for automatic generation of mobile applications to assist health professionals. The purpose of this research is to enable health professionals to develop applications from the description of their own clinical protocols. As a result, we developed a web system that automates clinical protocols for an Android platform, and we validated with two clinical protocols used in a Brazilian hospital. Preliminary results of the developed architecture demonstrate the feasibility of this study.

  12. What can Natural Language Processing do for Clinical Decision Support?

    PubMed Central

    Demner-Fushman, Dina; Chapman, Wendy W.; McDonald, Clement J.

    2009-01-01

    Computerized Clinical Decision Support (CDS) aims to aid decision making of health care providers and the public by providing easily accessible health-related information at the point and time it is needed. Natural Language Processing (NLP) is instrumental in using free-text information to drive CDS, representing clinical knowledge and CDS interventions in standardized formats, and leveraging clinical narrative. The early innovative NLP research of clinical narrative was followed by a period of stable research conducted at the major clinical centers and a shift of mainstream interest to biomedical NLP. This review primarily focuses on the recently renewed interest in development of fundamental NLP methods and advances in the NLP systems for CDS. The current solutions to challenges posed by distinct sublanguages, intended user groups, and support goals are discussed. PMID:19683066

  13. 45 CFR 310.40 - What requirements apply for accessing systems and records for monitoring Computerized Tribal IV-D...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... records for monitoring Computerized Tribal IV-D Systems and Office Automation? 310.40 Section 310.40... COMPUTERIZED TRIBAL IV-D SYSTEMS AND OFFICE AUTOMATION Accountability and Monitoring Procedures for... monitoring Computerized Tribal IV-D Systems and Office Automation? In accordance with Part 95 of this title...

  14. CogState computerized memory tests in patients with brain metastases: secondary endpoint results of NRG Oncology RTOG 0933.

    PubMed

    Caine, Chip; Deshmukh, Snehal; Gondi, Vinai; Mehta, Minesh; Tomé, Wolfgang; Corn, Benjamin W; Kanner, Andrew; Rowley, Howard; Kundapur, Vijayananda; DeNittis, Albert; Greenspoon, Jeffrey Noah; Konski, Andre A; Bauman, Glenn S; Raben, Adam; Shi, Wenyin; Wendland, Merideth; Kachnic, Lisa

    2016-01-01

    Whole brain radiotherapy (WBRT) is associated with memory dysfunction. As part of NRG Oncology RTOG 0933, a phase II study of WBRT for brain metastases that conformally avoided the hippocampal stem cell compartment (HA-WBRT), memory was assessed pre- and post-HA-WBRT using both traditional and computerized memory tests. We examined whether the computerized tests yielded similar findings and might serve as possible alternatives for assessment of memory in multi-institution clinical trials. Adult patients with brain metastases received HA-WBRT to 30 Gy in ten fractions and completed Hopkins Verbal Learning Test-Revised (HVLT-R), CogState International Shopping List Test (ISLT) and One Card Learning Test (OCLT), at baseline, 2 and 4 months. Tests' completion rates were 52-53 % at 2 months and 34-42 % at 4 months. All baseline correlations between HVLT-R and CogState tests were significant (p ≤ 0.003). At baseline, both CogState tests and one component of HVLT-R differentiated those who were alive at 6 months and those who had died (p ≤ 0.01). At 4 months, mean relative decline was 7.0 % for HVLT-R Delayed Recall and 18.0 % for ISLT Delayed Recall. OCLT showed an 8.0 % increase. A reliable change index found no significant changes from baseline to 2 and 4 months for ISLT Delayed Recall (z = -0.40, p = 0.34; z = -0.68, p = 0.25) or OCLT (z = 0.15, p = 0.56; z = 0.41, p = 0.66). Study findings support the possibility that hippocampal avoidance may be associated with preservation of memory test performance, and that these computerized tests also may be useful and valid memory assessments in multi-institution adult brain tumor trials.

  15. Age, sex, and symptom intensity influence test taking parameters on functional patient-reported outcomes.

    PubMed

    Cheville, Andrea L; Wang, Chun; Ni, Pengsheng; Jette, Alan M; Basford, Jeffrey R

    2014-11-01

    Item response theory-based patient-reported outcomes such as the Activity Measure for Post Acute Care Computerized Adaptive Test are gaining use because of their flexibility and ease of administration. Their psychometric properties are being explored, but little is known about how respondent characteristics may impact precision. The goal of this study was, therefore, to assess the effects of age, sex, and symptom intensity on respondents' test taking behaviors and scores. Three hundred eleven adults with late-stage lung cancer were consecutively enrolled between April 2008 and April 2009. Demographics and comorbidities were abstracted from their electronic medical records. The participants were followed on a 3- to 4-wk basis by telephonic interviews that involved administration of the Activity Measure for Post Acute Care Computerized Adaptive Test, followed by numerical rating scales scoring of their pain, fatigue, and dyspnea. In more than 2538 computerized adaptive test (CAT) sessions, three findings were prominent. First, the women and the older patients took longer to complete CAT sessions, were more likely to skip items, and produced scores with larger standard errors. Second, the respondents with higher levels of dyspnea and fatigue, but not pain, completed their CAT sessions more rapidly and were less likely to skip items. Third, fatigue and dyspnea interact with age but not sex to influence CAT duration and skip count. The findings of this study suggest that certain common clinical populations, for example, women, geriatric patients, and patients with intense symptoms, differ systematically in the time they are willing to devote to testing and the precision of their responses. The latter finding, unstable precision, is unlikely to be CAT specific and has implications for the interpretation of the scores of the Activity Measure for Post Acute Care Computerized Adaptive Test and other patient-reported outcomes.

  16. Validation of Computerized Adaptive Testing in an Outpatient Non-academic Setting: the VOCATIONS Trial

    PubMed Central

    Achtyes, Eric Daniel; Halstead, Scott; Smart, LeAnn; Moore, Tara; Frank, Ellen; Kupfer, David J.; Gibbons, Robert

    2015-01-01

    Objective Computerized adaptive tests (CAT) provide an alternative to fixed-length assessments for diagnostic screening and severity measurement of psychiatric disorders. We sought to cross-sectionally validate a suite of computerized adaptive tests for mental health (CAT-MH) in a community psychiatric sample. Methods 145 adult psychiatric outpatients and controls were prospectively evaluated with CAT for depression, mania and anxiety symptoms, compared to gold-standard psychiatric assessments including: Structured Clinical Interview for DSM IV-TR (SCID), Hamilton Rating Scale for Depression (HAM-D25), Patient Health Questionnaire (PHQ-9), Center for Epidemiologic Studies Depression Scale (CES-D), and Global Assessment of Functioning (GAF). Results Sensitivity and specificity for the computerized adaptive diagnostic test for depression (CAD-MDD) were .96 and .64, respectively (.96 and 1.00 for major depression versus controls). CAT for depression severity (CAT-DI) correlated well to standard depression scales HAM-D25 (r=.79), PHQ-9 (r=.90), CES-D (r=.90) and had OR=27.88 for current SCID major depressive disorder diagnosis across its range. CAT for anxiety severity (CAT-ANX) correlated to HAM-D25 (r=.73), PHQ-9 (r=.78), CES-D (r=.81), and had OR=11.52 for current SCID generalized anxiety disorder diagnosis across its range. CAT for mania severity (CAT-MANIA) did not correlate well to HAM-D25 (r=.31), PHQ-9 (r=.37), CES-D (r=.39), but had an OR=11.56 for a current SCID bipolar diagnosis across its range. Participants found the CAT-MH suite of tests acceptable and easy to use, averaging 51.7 items and 9.4 minutes to complete the full battery. Conclusions Compared to current gold-standard diagnostic and assessment measures, CAT-MH provides an effective, rapidly-administered assessment of psychiatric symptoms. PMID:26030317

  17. COMPUTERIZED EXPERT SYSTEM FOR EVALUATION OF AUTOMATED VISUAL FIELDS FROM THE ISCHEMIC OPTIC NEUROPATHY DECOMPRESSION TRIAL: METHODS, BASELINE FIELDS, AND SIX-MONTH LONGITUDINAL FOLLOW-UP

    PubMed Central

    Feldon, Steven E

    2004-01-01

    ABSTRACT Purpose To validate a computerized expert system evaluating visual fields in a prospective clinical trial, the Ischemic Optic Neuropathy Decompression Trial (IONDT). To identify the pattern and within-pattern severity of field defects for study eyes at baseline and 6-month follow-up. Design Humphrey visual field (HVF) change was used as the outcome measure for a prospective, randomized, multi-center trial to test the null hypothesis that optic nerve sheath decompression was ineffective in treating nonarteritic anterior ischemic optic neuropathy and to ascertain the natural history of the disease. Methods An expert panel established criteria for the type and severity of visual field defects. Using these criteria, a rule-based computerized expert system interpreted HVF from baseline and 6-month visits for patients randomized to surgery or careful follow-up and for patients who were not randomized. Results A computerized expert system was devised and validated. The system was then used to analyze HVFs. The pattern of defects found at baseline for patients randomized to surgery did not differ from that of patients randomized to careful follow-up. The most common pattern of defect was a superior and inferior arcuate with central scotoma for randomized eyes (19.2%) and a superior and inferior arcuate for nonrandomized eyes (30.6%). Field patterns at 6 months and baseline were not different. For randomized study eyes, the superior altitudinal defects improved (P = .03), as did the inferior altitudinal defects (P = .01). For nonrandomized study eyes, only the inferior altitudinal defects improved (P = .02). No treatment effect was noted. Conclusions A novel rule-based expert system successfully interpreted visual field defects at baseline of eyes enrolled in the IONDT. PMID:15747764

  18. A combination of physical activity and computerized brain training improves verbal memory and increases cerebral glucose metabolism in the elderly.

    PubMed

    Shah, T; Verdile, G; Sohrabi, H; Campbell, A; Putland, E; Cheetham, C; Dhaliwal, S; Weinborn, M; Maruff, P; Darby, D; Martins, R N

    2014-12-02

    Physical exercise interventions and cognitive training programs have individually been reported to improve cognition in the healthy elderly population; however, the clinical significance of using a combined approach is currently lacking. This study evaluated whether physical activity (PA), computerized cognitive training and/or a combination of both could improve cognition. In this nonrandomized study, 224 healthy community-dwelling older adults (60-85 years) were assigned to 16 weeks home-based PA (n=64), computerized cognitive stimulation (n=62), a combination of both (combined, n=51) or a control group (n=47). Cognition was assessed using the Rey Auditory Verbal Learning Test, Controlled Oral Word Association Test and the CogState computerized battery at baseline, 8 and 16 weeks post intervention. Physical fitness assessments were performed at all time points. A subset (total n=45) of participants underwent [(18)F] fluorodeoxyglucose positron emission tomography scans at 16 weeks (post-intervention). One hundred and ninety-one participants completed the study and the data of 172 participants were included in the final analysis. Compared with the control group, the combined group showed improved verbal episodic memory and significantly higher brain glucose metabolism in the left sensorimotor cortex after controlling for age, sex, premorbid IQ, apolipoprotein E (APOE) status and history of head injury. The higher cerebral glucose metabolism in this brain region was positively associated with improved verbal memory seen in the combined group only. Our study provides evidence that a specific combination of physical and mental exercises for 16 weeks can improve cognition and increase cerebral glucose metabolism in cognitively intact healthy older adults.

  19. A combination of physical activity and computerized brain training improves verbal memory and increases cerebral glucose metabolism in the elderly

    PubMed Central

    Shah, T; Verdile, G; Sohrabi, H; Campbell, A; Putland, E; Cheetham, C; Dhaliwal, S; Weinborn, M; Maruff, P; Darby, D; Martins, R N

    2014-01-01

    Physical exercise interventions and cognitive training programs have individually been reported to improve cognition in the healthy elderly population; however, the clinical significance of using a combined approach is currently lacking. This study evaluated whether physical activity (PA), computerized cognitive training and/or a combination of both could improve cognition. In this nonrandomized study, 224 healthy community-dwelling older adults (60–85 years) were assigned to 16 weeks home-based PA (n=64), computerized cognitive stimulation (n=62), a combination of both (combined, n=51) or a control group (n=47). Cognition was assessed using the Rey Auditory Verbal Learning Test, Controlled Oral Word Association Test and the CogState computerized battery at baseline, 8 and 16 weeks post intervention. Physical fitness assessments were performed at all time points. A subset (total n=45) of participants underwent [18F] fluorodeoxyglucose positron emission tomography scans at 16 weeks (post-intervention). One hundred and ninety-one participants completed the study and the data of 172 participants were included in the final analysis. Compared with the control group, the combined group showed improved verbal episodic memory and significantly higher brain glucose metabolism in the left sensorimotor cortex after controlling for age, sex, premorbid IQ, apolipoprotein E (APOE) status and history of head injury. The higher cerebral glucose metabolism in this brain region was positively associated with improved verbal memory seen in the combined group only. Our study provides evidence that a specific combination of physical and mental exercises for 16 weeks can improve cognition and increase cerebral glucose metabolism in cognitively intact healthy older adults. PMID:25463973

  20. Development and evaluation of a computerized intervention for low distress tolerance and its effect on performance on a neutralization task.

    PubMed

    Macatee, Richard J; Cougle, Jesse R

    2015-09-01

    A growing body of research has linked high distress intolerance (DI) to obsessions, but not other OCD symptom domains. However, existing research is correlational. Experimental studies are needed, but brief methods for reducing DI are lacking. To address these gaps in the literature, a brief, computerized intervention aimed at reducing DI was developed to determine if changing DI affected obsessional phenomena. Individuals reporting high DI were randomized to a treatment or waitlist control group (N = 53). Individuals in the treatment group received the DI treatment (i.e., a 2 h computerized intervention) over two weeks, and then underwent a post-assessment in which DI and obsession-relevant phenomena were measured. Individuals in the control group only received the post-assessment. Analyses revealed a greater reduction in self-reported DI on one measure and smaller decreases in behavioral DI in the intervention condition relative to the waitlist condition, as well as lower in-vivo urges to neutralize an intrusive thought; however, anxious reactivity to the intrusion and neutralization behavior were not affected. Further, bootstrapping analyses revealed that reductions in DI mediated the effect of the intervention on neutralization urges. A clinical sample and placebo control condition were not used. These results provide experimental evidence for the role of DI in obsessional phenomena, specifically in affecting urges to neutralize intrusions, findings consistent with negative reinforcement models of DI. Further, results revealed that DI can be reduced with a brief, computerized intervention, which has important implications for future experimental research and treatment development. Copyright © 2015 Elsevier Ltd. All rights reserved.

Top