Sample records for clinical examination mammography

  1. As mammography use increases, are some providers omitting clinical breast examination?

    PubMed

    Burns, R B; Freund, K M; Ash, A S; Shwartz, M; Antab, L; Hall, R

    1996-04-08

    To explore use of clinical breast examination (CBE) among women receiving mammography. A retrospective cohort analysis of 100 women aged 50 years or older with at least one bilateral mammogram. Chart review documented demographic information, severity of illness, and performance of CBE (from 1 year prior to 18 months after the mammogram). The mean age of the 100 women was 63 years. They were predominantly unmarried (60%), nonwhite (58%), and not currently employed (57%). Three quarters (76%) had mammography and CBE (comprehensive screening), while the remaining 24% had mammography only. Sociodemographic factors did not differ for women with and without comprehensive screening (P>.1). However, patients of female providers were more likely to receive comprehensive screening than patients of male providers. Specifically, 95% of women seen by female attending physicians or fellows had comprehensive screening vs 67% for male attending physicians or fellows and 61% for residents (P=.008). Mammography may be replacing CBE especially among patients of male providers. Interventions targeted to these providers could help improve the use of CBE and mammography.

  2. Cost-effectiveness analysis of mammography and clinical breast examination strategies

    PubMed Central

    Ahern, Charlotte Hsieh; Shen, Yu

    2009-01-01

    Purpose Breast cancer screening by mammography and clinical breast exam are commonly used for early tumor detection. Previous cost-effectiveness studies considered mammography alone or did not account for all relevant costs. In this study, we assessed the cost-effectiveness of screening schedules recommended by three major cancer organizations and compared them with alternative strategies. We considered costs of screening examinations, subsequent work-up, biopsy, and treatment interventions after diagnosis. Methods We used a microsimulation model to generate women’s life histories, and assessed screening and treatment impacts on survival. Using statistical models, we accounted for age-specific incidence, preclinical disease duration, and age-specific sensitivity and specificity for each screening modality. The outcomes of interest were quality-adjusted life years (QALYs) saved and total costs with a 3% annual discount rate. Incremental cost-effectiveness ratios were used to compare strategies. Sensitivity analyses were performed by varying some of the assumptions. Results Compared to guidelines from the National Cancer Institute and the U.S. Preventive Services Task Force, alternative strategies were more efficient. Mammography and clinical breast exam in alternating years from ages 40 to 79 was a cost-effective alternative compared to the guidelines, costing $35,500 per QALY saved compared with no screening. The American Cancer Society guideline was the most effective and the most expensive, costing over $680,000 for an added QALY compared to the above alternative. Conclusion Screening strategies with lower costs and benefits comparable to those currently recommended should be considered for implementation in practice and for future guidelines. PMID:19258473

  3. A cost simulation for mammography examinations taking into account equipment failures and resource utilization characteristics.

    PubMed

    Coelli, Fernando C; Almeida, Renan M V R; Pereira, Wagner C A

    2010-12-01

    This work develops a cost analysis estimation for a mammography clinic, taking into account resource utilization and equipment failure rates. Two standard clinic models were simulated, the first with one mammography equipment, two technicians and one doctor, and the second (based on an actually functioning clinic) with two equipments, three technicians and one doctor. Cost data and model parameters were obtained by direct measurements, literature reviews and other hospital data. A discrete-event simulation model was developed, in order to estimate the unit cost (total costs/number of examinations in a defined period) of mammography examinations at those clinics. The cost analysis considered simulated changes in resource utilization rates and in examination failure probabilities (failures on the image acquisition system). In addition, a sensitivity analysis was performed, taking into account changes in the probabilities of equipment failure types. For the two clinic configurations, the estimated mammography unit costs were, respectively, US$ 41.31 and US$ 53.46 in the absence of examination failures. As the examination failures increased up to 10% of total examinations, unit costs approached US$ 54.53 and US$ 53.95, respectively. The sensitivity analysis showed that type 3 (the most serious) failure increases had a very large impact on the patient attendance, up to the point of actually making attendance unfeasible. Discrete-event simulation allowed for the definition of the more efficient clinic, contingent on the expected prevalence of resource utilization and equipment failures. © 2010 Blackwell Publishing Ltd.

  4. Accuracy of Physical Examination, Ultrasonography, and Mammography in Predicting Residual Pathologic Tumor Size in Patients Treated With Neoadjuvant Chemotherapy

    PubMed Central

    Chagpar, Anees B.; Middleton, Lavinia P.; Sahin, Aysegul A.; Dempsey, Peter; Buzdar, Aman U.; Mirza, Attiqa N.; Ames, Fredrick C.; Babiera, Gildy V.; Feig, Barry W.; Hunt, Kelly K.; Kuerer, Henry M.; Meric-Bernstam, Funda; Ross, Merrick I.; Singletary, S Eva

    2006-01-01

    Objective: To assess the accuracy of physical examination, ultrasonography, and mammography in predicting residual size of breast tumors following neoadjuvant chemotherapy. Background: Neoadjuvant chemotherapy is an accepted part of the management of stage II and III breast cancer. Accurate prediction of residual pathologic tumor size after neoadjuvant chemotherapy is critical in guiding surgical therapy. Although physical examination, ultrasonography, and mammography have all been used to predict residual tumor size, there have been conflicting reports about the accuracy of these methods in the neoadjuvant setting. Methods: We reviewed the records of 189 patients who participated in 1 of 2 protocols using doxorubicin-containing neoadjuvant chemotherapy, and who had assessment by physical examination, ultrasonography, and/or mammography no more than 60 days before their surgical resection. Size correlations were performed using Spearman rho analysis. Clinical and pathologic measurements were also compared categorically using the weighted kappa statistic. Results: Size estimates by physical examination, ultrasonography, and mammography were only moderately correlated with residual pathologic tumor size after neoadjuvant chemotherapy (correlation coefficients: 0.42, 0.42, and 0.41, respectively), with an accuracy of ±1 cm in 66% of patients by physical examination, 75% by ultrasonography, and 70% by mammography. Kappa values (0.24–0.35) indicated poor agreement between clinical and pathologic measurements. Conclusion: Physical examination, ultrasonography, and mammography were only moderately useful for predicting residual pathologic tumor size after neoadjuvant chemotherapy. PMID:16432360

  5. Prospective validation of a blood-based 9-miRNA profile for early detection of breast cancer in a cohort of women examined by clinical mammography.

    PubMed

    Lyng, Maria B; Kodahl, Annette R; Binder, Harald; Ditzel, Henrik J

    2016-12-01

    Mammography is the predominant screening method for early detection of breast cancer, but has limitations and could be rendered more accurate by combination with a blood-based biomarker profile. Circulating microRNAs (miRNAs) are increasingly recognized as strong biomarkers, and we previously developed a 9-miRNA profile using serum and LNA-based qPCR that effectively stratified patients with early stage breast cancer vs. healthy women. To further develop the test into routine clinical practice, we collected serum of women examined by clinical mammography (N = 197) according to standard operational procedures (SOPs) of the Danish Cancer Biobank. The performance of the circulating 9-miRNA profile was analyzed in 116 of these women, including 36 with breast cancer (aged 50-74), following a standardized protocol that mimicked a routine clinical set-up. We confirmed that the profile is significantly different between women with breast cancer and controls (p-value <0.0001), with an AUC of 0.61. Significantly, one woman whose 9-miRNA profile predicted a 73% probability of having breast cancer indeed developed the disease within one year despite being categorized as clinically healthy at the time of blood sample collection and mammography. We propose that this miRNA profile combined with mammography will increase the overall accuracy of early detection of breast cancer. Copyright © 2016 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  6. Breast cancer screening (breast self-examination, clinical breast exam, and mammography) in women referred to health centers in Tabriz, Iran.

    PubMed

    Khalili, Azizeh Farshbaf; Shahnazi, Mahnaz

    2010-04-01

    Breast cancer is the most common cancer and the most common cause of death in Iranian women aged 35-55 years. Breast cancer screening comprises breast self-examination (BSE), clinical breast examination (CBE) and mammography. The study aimed to examine the performance of screening methods among women referring to health centers of Tabriz, Iran. This was a descriptive-analytical research carried out on 400 women aged 20-50 years. The samples were chosen through random multistage sampling among health centers of Tabriz then active records of women. A questionnaire and observational checklist was used to elicit socio-demographic information and performance of women towards breast cancer screening methods. Descriptive and inferential statistics (chi-square and Fisher's exact test) were used to analyze the data. Only 18.8% of women did breast self-examination, 19.1% had clinical breast examination and 3.3% had mammogram. Statistical test showed a significant relationship between performing BSE and educational level, employment, income, number of children, breastfeeding history, breastfeeding quality and family history of breast cancer. There was a significant correlation between performing CBE and history of breast tumor and also, between performing the mammography and family history of breast cancer and history of breast tumor (P < 0.05). The findings showed that the performance of breast cancer screening methods was not satisfactory. Performance in high risk women was very desirable than others. The presentation of imperative education about breast cancer screening methods through health staff especially in pregnancy, post-partum and even in pre marriage counseling periods seems necessary.

  7. The Influence of Breast Self-Examination on Subsequent Mammography Participation

    PubMed Central

    Jelinski, Susan E.; Maxwell, Colleen J.; Onysko, Jay; Bancej, Christina M.

    2005-01-01

    Objectives. We evaluated whether breast self-examination (BSE) influences subsequent mammography participation. Methods. We evaluated associations between BSE and subsequent mammography participation, adjusting for baseline screening behaviors and sociodemographic, health, and lifestyle characteristics, among women aged 40 years and older using data from the longitudinal Canadian National Population Health Survey. Results. Regular performance of BSE at baseline was not associated with receipt of a recent mammogram at follow-up among all women (adjusted odds ratio [OR]=1.01; 95% confidence interval [CI]= 0.75, 1.35) or with mammography uptake among the subgroup of women reporting never use at baseline (adjusted OR=0.78; 95% CI=0.50, 1.22). Conclusions. The lack of association between performance of BSE and subsequent mammography participation suggests that not recommending BSE is unlikely to influence mammography participation. PMID:15727985

  8. Synthesized Mammography: Clinical Evidence, Appearance, and Implementation.

    PubMed

    Durand, Melissa A

    2018-04-04

    Digital breast tomosynthesis (DBT) has improved conventional mammography by increasing cancer detection while reducing recall rates. However, these benefits come at the cost of increased radiation dose. Synthesized mammography (s2D) has been developed to provide the advantages of DBT with nearly half the radiation dose. Since its F.D.A. approval, multiple studies have evaluated the clinical performance of s2D. In clinical practice, s2D images are not identical to conventional 2D images and are designed for interpretation with DBT as a complement. This article reviews the present literature to assess whether s2D is a practical alternative to conventional 2D, addresses the differences in mammographic appearance of findings, and provides suggestions for implementation into clinical practice.

  9. Implementation of a clinical quality control program in a mammography screening service of Brazil.

    PubMed

    DE Souza Sabino, Silvia Maria Prioli; Silva, Thiago Buosi; Watanabe, Anapaula Hidemi Uema; Syrjänen, Kari; Carvalho, André Lopes; Mauad, Edmundo Carvalho

    2014-09-01

    To evaluate the effect of a clinical quality control program on the final quality of a mammography screening service. We conducted retrospective assessment of the clinical quality of 5,000 mammograms taken in a Mammography Screening Program between November 2010 and September 2011, following the implementation of a Clinical Quality Control Program based on the European Guidelines. Among the 105,000 evaluated quality items, there were 8,588 failures (8.2%) - 1.7 failures per examination. Altogether, 89% of the failures were associated with positioning. The recall rate due to a technical error reached a maximum of 0.5% in the early phase of the observation period and subsequently stabilized (0.09%). The ongoing education and monitoring combined with personalized training increased the critical thinking of the involved professionals, reducing the technical failures and unnecessary exposure of patients to radiation, with substantial improvement in the final quality of mammography. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  10. European radiographers' challenges from mammography education and clinical practice - an integrative review.

    PubMed

    Metsälä, Eija; Richli Meystre, Nicole; Pires Jorge, José; Henner, Anja; Kukkes, Tiina; Sá Dos Reis, Cláudia

    2017-06-01

    This study aims to identify European radiographers' challenges in clinical performance in mammography and the main areas of mammography that require more and better training. An extensive search was performed to identify relevant studies focused on clinical practice, education and training in mammography published between January 2010 and December 2015 in the English language. The data were analysed by using deductive thematic analysis. A total of 27 full text articles were read, evaluating their quality. Sixteen articles out of 27 were finally selected for this integrative review. The main challenges of radiographers' mammography education/training can be divided into three groups: training needs, challenges related to radiographers, and challenges related to the organization of education. The most common challenges of clinical performance in mammography among European radiographers involved technical performance, the quality of practices, and patient-centeredness. The introduction of harmonized mammography guidelines across Europe may serve as an evidence-based tool to be implemented in practice and education. However, the variability in human and material resources as well as the different cultural contexts should be considered during this process. • Radiographers' awareness of their professional identity and enhancing multiprofessional cooperation in mammography. • Radiographers' responsibilities regarding image quality (IQ) and optimal breast imaging performance. • Patient-centred mammography services focusing on the psychosocial needs of the patient. • Challenges: positioning, QC-testing, IQ-assessment, optimization of breast compression, communication, teamwork, and patient-centred care. • Introduction of evidence-based guidelines in Europe to harmonize mammography practice and education.

  11. Automatic patient dose registry and clinical audit on line for mammography.

    PubMed

    Ten, J I; Vano, E; Sánchez, R; Fernandez-Soto, J M

    2015-07-01

    The use of automatic registry systems for patient dose in digital mammography allows clinical audit and patient dose analysis of the whole sample of individual mammography exposures while fulfilling the requirements of the European Directives and other international recommendations. Further parameters associated with radiation exposure (tube voltage, X-ray tube output and HVL values for different kVp and target/filter combinations, breast compression, etc.) should be periodically verified and used to evaluate patient doses. This study presents an experience in routine clinical practice for mammography using automatic systems. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Cost and cost-effectiveness of digital mammography compared with film-screen mammography in Australia.

    PubMed

    Wang, Shuhong; Merlin, Tracy; Kreisz, Florian; Craft, Paul; Hiller, Janet E

    2009-10-01

    A systematic review assessed the relative safety and effectiveness of digital mammography compared with film-screen mammography. This study utilised the evidence from the review to examine the economic value of digital compared with film-screen mammography in Australia. A cost-comparison analysis between the two technologies was conducted for the overall population for the purposes of breast cancer screening and diagnosis. In addition, a cost-effectiveness analysis was conducted for the screening subgroups where digital mammography was considered to be more accurate than film-screen mammography. Digital mammography in a screening setting is $11 more per examination than film-screen mammography, and $36 or $33 more per examination in a diagnostic setting when either digital radiography or computed radiography is used. In both the screening and diagnostic settings, the throughput of the mammography system had the most significant impact on decreasing the incremental cost/examination/year of digital mammography. Digital mammography is more expensive than film-screen mammography. Whether digital mammography represents good value for money depends on the eventual life-years and quality-adjusted life-years gained from the early cancer diagnosis. The evidence generated from this study has informed the allocation of public resources for the screening and diagnosis of breast cancer in Australia.

  13. Digital Mammography and Digital Breast Tomosynthesis.

    PubMed

    Moseley, Tanya W

    2016-06-01

    Breast imaging technology has advanced significantly from the 1930s until the present. American women have a 1 in 8 chance of developing breast cancer. Mammography has been proven in multiple clinical trials to reduce breast cancer mortality. Although a mainstay of breast imaging and improved from film-screen mammography, digital mammography is not a perfect examination. Overlapping obscuring breast tissue limits mammographic interpretation. Breast digital tomosynthesis reduces and/or eliminates overlapping obscuring breast tissue. Although there are some disadvantages with digital breast tomosynthesis, this relatively lost-cost technology may be used effectively in the screening and diagnostic settings.

  14. Screening Mammography and Digital Breast Tomosynthesis: Utilization Updates.

    PubMed

    Boroumand, Gilda; Teberian, Ida; Parker, Laurence; Rao, Vijay M; Levin, David C

    2018-05-01

    There have been many recent developments in breast imaging, including the 2009 revision of the U.S. Preventive Services Task Force's breast cancer screening guidelines and the approval of digital breast tomosynthesis (DBT) for clinical use in 2011. The objective of this study is to evaluate screening mammography utilization trends among the Medicare population from 2005 to 2015 and examine the volume of DBT studies performed in 2015, the first year for which procedural billing codes for DBT are available. We reviewed national Medicare Part B Physician/Supplier Procedure Summary master files from 2005 to 2015, to determine the annual utilization rate of screening mammography on the basis of procedure codes used for film-screen and digital screening mammography. We also used the Physician/Supplier Procedure Summary master files to determine the volume of screening and diagnostic DBT studies performed in 2015. The utilization rate of screening mammography per 1000 women in the Medicare fee-for-service population increased gradually every year, from 311.5 examinations in 2005 to a peak of 322.9 examinations in 2009, representing a compound annual growth rate of 0.9%. In 2010, the utilization rate abruptly decreased by 4.3% to 309.2 examinations, and it has not since recovered to pre-2010 levels. In 2015, 18.9% of screening and 16.2% of diagnostic digital mammography examinations included DBT as an add-on procedure. In contrast to the annual increase in screening mammography utilization from 2005 to 2009, an abrupt sustained decline in screening occurred beginning in 2010, coinciding with the release of U.S. Preventive Services Task Force recommendations. DBT utilization was somewhat limited in 2015, occurring in conjunction with less than 20% of digital mammography examinations.

  15. Value of mammography and breast ultrasound in male patients with nipple discharge.

    PubMed

    Muñoz Carrasco, Rafaela; Álvarez Benito, Marina; Rivin del Campo, Eleonor

    2013-03-01

    To assess the contribution of mammography and ultrasound in men with nipple discharge. All men with nipple discharge who underwent mammography and/or ultrasound between 1993 and 2011 in our hospital were retrospectively evaluated. Radiological findings were classified according to BI-RADS lexicon. The final diagnosis was made based on histopathological results or clinical-radiological follow-up. The diagnostic performance of physical examination, mammography and ultrasound was calculated and compared. 26 men with 21 mammograms and 19 ultrasounds were reviewed. The final diagnoses were: 6 carcinomas (23.1%), 10 gynaecomastias, 2 pseudogynaecomastias and 8 normal breast tissues. Mammograms and ultrasounds performed on all five patients with infiltrating carcinoma showed a mass (categories 4 and 5). In all these patients except one, a breast mass was also noted and the physical examination was positive or suspected malignancy. In the patient with carcinoma in situ, the only conspicuous clinical sign was bloody nipple discharge and the mammography showed calcifications (category 4) that were not visible on ultrasound. Radiological findings of all patients without malignancy were classified as categories 1 and 2. The diagnostic performance of physical examination was lower than mammography and ultrasound (P>0.05). Mammography was more sensitive than ultrasound (100% vs. 83.3%). Both techniques showed the same specificity (100%). Men with nipple discharge have a high incidence of breast carcinoma. Nipple discharge may be the only clinical sign of carcinoma in situ. Mammography and ultrasound are useful in the evaluation of men with nipple discharge, diagnosing carcinoma in initial stages, avoiding unnecessary biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. Technetium-99m sestamibi scintimammography complements mammography in the detection of breast cancer.

    PubMed

    Krishnaiah, Gayathri; Sher-Ahmed, Arifa; Ugwu-Dike, Martins; Regan, Patricia; Singer, John; Totoonchie, Adil; Spiegler, Ethan; Sardi, Armando

    2003-01-01

    Mammography remains the technique of choice for the detection of early breast cancer. The sensitivity of mammography is 85%, but is decreased in patients with dense breasts. Sestamibi scintimammography (SCM) has been suggested as an adjunctive modality to improve the detection of breast cancer. We conducted a study to determine the impact of SCM in patient management. A prospective study was conducted in 95 patients presenting with palpable masses and/or abnormal mammography scheduled for biopsy. Injection of 20-30 mCi of technetium-99m (Tc-99m) sestamibi into a pedal vein was performed. Ten-minute images of the breast and axilla were obtained in multiple projections. The mammography and SCM were correlated with pathology and clinical findings. The median age was 44 years (range 28-86 years). The total number of lesions was 104, as eight patients had bilateral lesions and one patient had two lesions in the same breast. Fifty-nine patients presented with palpable lesions and 45 patients with nonpalpable lesions (42 with abnormal mammography only and 3 with nipple discharge). A comparison of sensitivity, specificity, positive and negative predictive values, and overall accuracy of SCM and mammography were performed. The sensitivity and specificity for SCM were 83% and 83%, respectively, and for mammography were 65%, and 72%, respectively. The sensitivity and specificity for combined SCM and mammography were 87% and 94%, respectively. The p-value for mammography versus combined SCM and mammography was 0.0003 and that for SCM versus SCM and mammography was 0.0098. There were 80 (77%) benign and 24 (23%) malignant lesions. Of the 24 malignancies, SCM missed six (25%), versus eight (33%) by mammography. In two patients (9%) SCM detected malignancy in the breast that was not visualized by mammography or found on clinical examination. Sestamibi SCM improves the sensitivity of mammography and it detects up to 9% of malignancies not detected by mammography or clinical

  17. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique; Alfonso, Beatriz Y. Álvarez; Castellanos, Gustavo Casian; Enríquez, Jesús Gabriel Franco

    2008-08-01

    The goal of the study was to evaluate the first CR digital mammography system (® Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.

  18. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez

    2008-08-11

    The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CRmore » Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.« less

  19. Breast dosimetry in clinical mammography

    NASA Astrophysics Data System (ADS)

    Benevides, Luis Alberto Do Rego

    The objective of this study was show that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. In the study, AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The protocol proposes the use of a fiber-optic coupled (FOCD) or Metal Oxide Semiconductor Field Effect Transistor (MOSFET) dosimeter to measure the entrance skin exposure at the time of the mammogram without interfering with diagnostic information of the mammogram. The study showed that FOCD had sensitivity with less than 7% energy dependence, linear in all tube current-time product stations, and was reproducible within 2%. FOCD was superior to MOSFET dosimeter in sensitivity, reusability, and reproducibility. The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. In addition, the study population anthropometric

  20. CR digital mammography: an affordable entry.

    PubMed

    Fischer, Cathy

    2006-01-01

    CR full-field digital mammography (FFDM) has been used extensively in other countries, and it was one of the 4 digital mammography technologies employed in the Digital Mammographic Imaging Screening Trial. Affordability and easy integration with pre-existing mammography systems makes CR FFDM an attractive way to secure the advantages of filmless mammography imaging. CR mammography is true digital mammography--it is merely a different way of acquiring the image. The FDA has recently approved the first CR FFDM system for sale in the United States. At Gundersen Lutheran Health System (La Crosse, Wisconsin), CR FFDM is the most practical technology for realizing the potential everyday clinical benefits of filmless mammography imaging.

  1. Dual-energy in mammography: feasibility study

    NASA Astrophysics Data System (ADS)

    Jafroudi, Hamid; Lo, Shih-Chung B.; Li, Huai; Steller Artz, Dorothy E.; Freedman, Matthew T.; Mun, Seong K.

    1996-04-01

    The purpose of this work is to examine the feasibility of dual-energy techniques to enhance the detection of microcalcifications in digital mammography. The digital mammography system used in this study consists of two different mammography systems; one is the conventional mammography system with molybdenum target and Mo filtration and the other is the clinical version of a low dose x-ray system with tungsten target and aluminum filtration. The low dose system is optimized for screen-film mammography with a highly efficient scatter rejection device built by Fischer Imaging Systems for evaluation at NIH. The system was designed by the University of Southern California based on multiparameter optimization techniques. Prototypes of this system have been constructed and evaluated at the Center for Devices and Radiological Health. The digital radiography system is based on the Fuji 9000 computed radiography (CR) system which uses a storage phosphor imaging plate as the receptor. High resolution plates (HR-V) are used in this study. Dual-energy is one technique to reduce the structured noise associated with the complexity of the background of normal anatomy surrounding a lesion. This can be done by taking the advantage of the x-ray attenuation characteristics of two different structures such as soft tissue and bone in chest radiography. We have applied this technique to the detection of microcalcifications in mammography. The overall system performance based on this technique is evaluated. Results presented are based on the evaluation of phantom images.

  2. Inequity of healthcare utilization on mammography examination and Pap smear screening in Thailand: Analysis of a population-based household survey

    PubMed Central

    2017-01-01

    Healthcare in Thailand is not equally distributed, and not all people can equally access healthcare resources even if they are covered by health insurance. To examine factors associated with the utilization of mammography examination for breast cancer and Pap smear screening for cervical cancer, data from the national reproductive health survey conducted by the National Statistical Office of Thailand in 2009 was examined. The survey was carried out on 15,074,126 women aged 30–59 years. The results showed that the wealthier respondents had more mammograms than did the lower-income groups. The concentration index was 0.144. The data on Pap smears for cervical cancer also showed that the wealthier respondents were more likely to have had a Pap smear than their lower-income counterparts. The concentration index was 0.054. Determinants of mammography examination were education, followed by health welfare and wealth index, whereas the determinants of Pap smear screening were wealth index, followed by health welfare and education. The government should support greater education for women because education was associated with socioeconomic status and wealth. There should be an increase in the number of screening campaigns, mobile clinics, and low-cost mammograms and continued support for accessibility to mammograms, especially in rural areas and low-income communities. PMID:28282430

  3. Breast cancer screening using tomosynthesis in combination with digital mammography.

    PubMed

    Friedewald, Sarah M; Rafferty, Elizabeth A; Rose, Stephen L; Durand, Melissa A; Plecha, Donna M; Greenberg, Julianne S; Hayes, Mary K; Copit, Debra S; Carlson, Kara L; Cink, Thomas M; Barke, Lora D; Greer, Linda N; Miller, Dave P; Conant, Emily F

    2014-06-25

    Mammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results. To determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. Retrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. Period 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. Recall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy. A total of 454,850 examinations (n=281,187 digital mammography; n=173,663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29,726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n=815 invasive; n=392 in situ). With digital mammography + tomosynthesis, 15,541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n=707 invasive; n=243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, -16 (95% CI, -18 to -14; P < .001); for biopsies, 18.1 (95% CI, 15.4-20.8) with digital mammography vs 19.3 (95% CI, 16.6-22.1) with digital mammography + tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis

  4. Dual-energy contrast-enhanced mammography.

    PubMed

    Travieso Aja, M M; Rodríguez Rodríguez, M; Alayón Hernández, S; Vega Benítez, V; Luzardo, O P

    2014-01-01

    The degree of vascularization in breast lesions is related to their malignancy. For this reason, functional diagnostic imaging techniques have become important in recent years. Dual-energy contrast-enhanced mammography is a new, apparently promising technique in breast cancer that provides information about the degree of vascularization of the lesion in addition to the morphological information provided by conventional mammography. This article describes the state of the art for dual-energy contrast-enhanced mammography. Based on 15 months' clinical experience, we illustrate this review with clinical cases that allow us to discuss the advantages and limitations of this technique. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  5. Breast Cancer Screening, Mammography, and Other Modalities.

    PubMed

    Fiorica, James V

    2016-12-01

    This article is an overview of the modalities available for breast cancer screening. The modalities discussed include digital mammography, digital breast tomosynthesis, breast ultrasonography, magnetic resonance imaging, and clinical breast examination. There is a review of pertinent randomized controlled trials, studies and meta-analyses which contributed to the evolution of screening guidelines. Ultimately, 5 major medical organizations formulated the current screening guidelines in the United States. The lack of consensus in these guidelines represents an ongoing controversy about the optimal timing and method for breast cancer screening in women. For mammography screening, the Breast Imaging Reporting and Data System lexicon is explained which corresponds with recommended clinical management. The presentation and discussion of the data in this article are designed to help the clinician individualize breast cancer screening for each patient.

  6. Teleradiology and screening mammography: a telemammography system evaluation and comparison to clinical results

    NASA Astrophysics Data System (ADS)

    Leader, Joseph K.; Chough, Denise; Clearfield, Ronald J.; Ganott, Marie A.; Hakim, Christiane; Hardesty, Lara; Shindel, Betty; Sumkin, Jules H.; Drescher, John M.; Maitz, Glenn S.; Gur, David

    2005-04-01

    Radiologists' performance reviewing and rating breast cancer screening mammography exams using a telemammography system was evaluated and compared with the actual clinical interpretations of the same interpretations. Mammography technologists from three remote imaging sites transmitted 245 exams to a central site (radiologists), which they (the technologists) believed needed additional procedures (termed "recall"). Current exam image data and non-image data (i.e., technologist's text message, technologist's graphic marks, patient's prior report, and Computer Aided Detection (CAD) results) were transmitted to the central site and displayed on three high-resolution, portrait monitors. Seven radiologists interpreted ("recall" or "no recall") the exams using the telemammography workstation in three separate multi-mode studies. The mean telemammography recall rates ranged from 72.3% to 82.5% while the actual clinical recall rates ranged from 38.4% to 42.3% across the three studies. Mean Kappa of agreement ranged from 0.102 to 0.213 and mean percent agreement ranged from 48.7% to 57.4% across the three studies. Eighty-seven percent of the disagreement interpretations occurred when the telemammography interpretation resulted in a recommendation to recall and the clinical interpretation resulted in a recommendation not to recall. The poor agreement between the telemammography and clinical interpretations may indicate a critical dependence on images from prior screening exams rather than any text based information. The technologists were sensitive, if not specific, to the mammography features and changes that may lead to recall. Using the telemammography system the radiologists were able to reduce the recommended recalls by the technologist by approximately 25 percent.

  7. A study on mastectomy samples to evaluate breast imaging quality and potential clinical relevance of differential phase contrast mammography.

    PubMed

    Hauser, Nik; Wang, Zhentian; Kubik-Huch, Rahel A; Trippel, Mafalda; Singer, Gad; Hohl, Michael K; Roessl, Ewald; Köhler, Thomas; van Stevendaal, Udo; Wieberneit, Nataly; Stampanoni, Marco

    2014-03-01

    Differential phase contrast and scattering-based x-ray mammography has the potential to provide additional and complementary clinically relevant information compared with absorption-based mammography. The purpose of our study was to provide a first statistical evaluation of the imaging capabilities of the new technique compared with digital absorption mammography. We investigated non-fixed mastectomy samples of 33 patients with invasive breast cancer, using grating-based differential phase contrast mammography (mammoDPC) with a conventional, low-brilliance x-ray tube. We simultaneously recorded absorption, differential phase contrast, and small-angle scattering signals that were combined into novel high-frequency-enhanced images with a dedicated image fusion algorithm. Six international, expert breast radiologists evaluated clinical digital and experimental mammograms in a 2-part blinded, prospective independent reader study. The results were statistically analyzed in terms of image quality and clinical relevance. The results of the comparison of mammoDPC with clinical digital mammography revealed the general quality of the images to be significantly superior (P < 0.001); sharpness, lesion delineation, as well as the general visibility of calcifications to be significantly more assessable (P < 0.001); and delineation of anatomic components of the specimens (surface structures) to be significantly sharper (P < 0.001). Spiculations were significantly better identified, and the overall clinically relevant information provided by mammoDPC was judged to be superior (P < 0.001). Our results demonstrate that complementary information provided by phase and scattering enhanced mammograms obtained with the mammoDPC approach deliver images of generally superior quality. This technique has the potential to improve radiological breast diagnostics.

  8. Relative value of physical examination, mammography, and breast sonography in evaluating the size of the primary tumor and regional lymph node metastases in women receiving neoadjuvant chemotherapy for locally advanced breast carcinoma.

    PubMed

    Herrada, J; Iyer, R B; Atkinson, E N; Sneige, N; Buzdar, A U; Hortobagyi, G N

    1997-09-01

    The purpose of this study was to correlate physical examination and sonographic and mammographic measurements of breast tumors and regional lymph nodes with pathological findings and to evaluate the effect of neoadjuvant chemotherapy on clinical Tumor-Node-Metastasis stage by noninvasive methods. This was a retrospective analysis of 100 patients with locally advanced breast cancer registered and treated in prospective trials of neoadjuvant chemotherapy. All patients received four cycles of a doxorubicin-containing regimen and had noninvasive evaluation of the primary tumor and regional lymph nodes before and after neoadjuvant chemotherapy by physical examination, sonography, and mammography and underwent breast surgery and axillary dissection within 5 weeks after completion of neoadjuvant chemotherapy. The correlations between clinical and pathological measurements were determined by Spearman rank correlation analysis. A proportional odds model was used to examine predictive values. Eighty-three patients had both a clinically detectable primary tumor and lymph node metastases. Sixty-four patients had a decrease in Tumor-Node-Metastasis stage after chemotherapy. For 54% of patients, there was concordance in clinical response between the primary tumor and lymph node compartment; for the rest, results were discordant. Physical examination correlated best with pathological findings in the measurement of the primary tumor (P = 0.0003), whereas sonography was the most accurate predictor of size for axillary lymph nodes (P = 0.0005). The combination of physical examination and mammography worked best for assessment of the primary tumor (P = 0.003), whereas combining physical examination with sonography gave optimal evaluation of regional lymph nodes (P = 0.0001). In conclusion, physical examination is the best noninvasive predictor of the real size of locally advanced primary breast cancer, whereas sonography correlates better with the real dimensions of axillary lymph

  9. Audit of mammography requests in Abakaliki, South-East Nigeria.

    PubMed

    Eni, U E; Ekwedigwe, K C; Sunday-Adeoye, I; Daniyan, Abc; Isikhuemen, M E

    2017-03-07

    Breast cancer is the leading cancer in women in both developed and developing countries. Screening mammography detects breast cancer even before a lump can be palpated, with better prognosis. The introduction of mammographic technique for screening breast cancer, despite its importance, has been slow to adopt and virtually non-existent in many parts of Sub-Saharan Africa including Nigeria. For this reason, the indications of mammography have not been well defined in our setting. The aim of this study was to audit our mammography requests, with a view to improving its application in our setting. This is a descriptive study carried out on 69 female patients who had mammography at the National Obstetric Fistula Centre, Abakaliki, from January 2014 to December 2015. Findings on clinical examination were entered in a proforma. Mammography was performed in craniocaudal and mediolateral views using the Lorad M-IV (film-screen) mammography machine. Data was analysed using the Statistical Package for Social Sciences (SPSS) version 21. All 69 patients were females. Their mean age was 42.1 ± 11 years. Majority of the patients (69.6%) were between 30 and 49 years. The commonest indication for mammography was breast lump which was found in 46 patients (66.7%). Breast pain was present in 36 (52.2%) of patients. The different Breast Imaging Reporting and Data System (BIRADS) categories were BIRADS 0: 20 (28.99%), BIRADS 1: 8 (11.59%), BIRADS 2: 9 (13.04%), BIRADS 3: 4 (5.8%), BIRADS 4: 19 (27.54%) and BIRADS 5: 9 (13.04%). Diagnostic mammography remains the commonest indication for mammography in our setting. Public awareness, poverty reduction and ready availability of mammography facilities are required to improve screening mammography in our setting.

  10. Digital Mammography in Young Women: Is a Single View Sufficient?

    PubMed

    Gossner, Johannes

    2016-03-01

    Single view mammography may be a less time consuming, more comfortable and radiation reduced alternative for young women, but there are no studies examining this approach after the implementation of digital mammography into clinical practice. Retrospective analysis of all mammographies performed in women younger than 40 years during a 24 month period. The sample consisted of 109 women with 212 examined breasts. All patients initially received standard two- view mammography. In the study setting the MLO- views were read by a single viewer and compared to a composite reference standard. In this sample 7 malignant findings were present and the review of the MLO-view detected 6 of them (85%). In patients with dense breasts 4 out of 5 malignant findings were found on the single-view (sensitivity 80%) and all 2 malignant findings were detected in patients with low breast density (sensitivity 100%). There were 7 false positive findings (3.3%). i.e. in total 8 out of 212 examined breasts were therefore misinterpreted (3.8%). Single view digital mammography detects the vast majority of malignant findings, especially in low density breast tissue and the rate of false-positive findings is within acceptable limits. Therefore this approach may be used in different scenarios (for example in increasing patient throughout in resource poor settings, reducing radiation burden in the young or in combination with ultrasound to use the strengths of both methods). More research on this topic is needed to establish its potential role in breast imaging.

  11. Optimization of contrast-enhanced spectral mammography depending on clinical indication.

    PubMed

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-10-01

    The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality.

  12. CADx Mammography

    NASA Astrophysics Data System (ADS)

    Costaridou, Lena

    Although a wide variety of Computer-Aided Diagnosis (CADx) schemes have been proposed across breast imaging modalities, and especially in mammography, research is still ongoing to meet the high performance CADx requirements. In this chapter, methodological contributions to CADx in mammography and adjunct breast imaging modalities are reviewed, as they play a major role in early detection, diagnosis and clinical management of breast cancer. At first, basic terms and definitions are provided. Then, emphasis is given to lesion content derivation, both anatomical and functional, considering only quantitative image features of micro-calcification clusters and masses across modalities. Additionally, two CADx application examples are provided. The first example investigates the effect of segmentation accuracy on micro-calcification cluster morphology derivation in X-ray mammography. The second one demonstrates the efficiency of texture analysis in quantification of enhancement kinetics, related to vascular heterogeneity, for mass classification in dynamic contrast-enhanced magnetic resonance imaging.

  13. Optimization of contrast-enhanced spectral mammography depending on clinical indication

    PubMed Central

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-01-01

    Abstract. The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality. PMID:26158058

  14. Intentions to Maintain Adherence to Mammography

    PubMed Central

    Bowling, J. Michael; Brewer, Noel T.; Lipkus, Isaac M.; Skinner, Celette Sugg; Strigo, Tara S.; Rimer, Barbara K.

    2008-01-01

    Abstract Objective Recent attention has focused on moving women from having initial mammograms to maintaining adherence to regular mammography schedules. We examined behavioral intentions to maintain mammography adherence, which include the likelihood of performing a behavior, and implementation intentions, specific action plans to obtain mammograms. Potential predictors were Theory of Planned Behavior constructs, previous barriers, previous mammography maintenance, and age. Methods Respondents were 2062 currently adherent women due for their next mammograms in 3–4 months according to American Cancer Society recommendations for annual screening. Statistical models were used to examine predictors of behavioral and two implementation intentions, including having thought about where women would get their next mammograms and having thought about making appointments. Results With the exception of pros, cons, and subjective norms, all variables predicted behavioral intentions (p ≤ 0.05). Stronger perceived control, previous mammography maintenance, and one barrier (vs. none) predicted being more likely to have thought about where to get their next mammograms. Previous maintenance and no barriers (vs. two) predicted being more likely to have thought about making appointments. Conclusions Our findings suggest that among women currently adherent to mammography, volitional factors, such as barriers, may be better predictors of implementation intentions than motivational factors, such as attitudes. Implementation variables may be useful in understanding how women move from intentions to action. Future research should examine how such factors relate to mammography maintenance behaviors and can be integrated into behavior change interventions. PMID:18657041

  15. Barriers and incentives for choosing to specialise in mammography: Qualitative analysis.

    PubMed

    Warren-Forward, H M; Taylor, J

    2017-02-01

    There is a projected shortage of radiographers working in breast screening and this study aimed to examine comments from open response questions from a mixed methods survey of current diagnostic radiography students on their perceptions of working in mammography. The survey asked three open ended questions: Justification of choice of modality in which they would want to specialise, why they believed there was a shortage of radiographers working in breast screening and any other comment about mammography. Reasons given for specialising in any modality was interest, feature of a modality, amount of clinical exposure during the degree program, personal issues and career prospects. Few current diagnostic radiography students indicated that they would be interested in specialising in breast imaging. They considered there to be a shortage of radiographers as breast imaging was seen to be repetitive, high pressure, intimate and gender biased. Lack of education, clinical exposure, limited career prospects and low pay were also discussed. Increasing education to the modality during the degree, allowing males to be involved in breast imaging and promoting part-time work in mammography while also working in other modalities may alter the perception that mammography offers a limited career pathway. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  16. Mammography: MedlinePlus Health Topic

    MedlinePlus

    ... National Center for Health Statistics) MQSA National Statistics (Food and Drug Administration) Women with Disabilities and Breast Cancer Screening (Centers for Disease Control and Prevention) Clinical Trials ClinicalTrials.gov: Mammography (National Institutes of ...

  17. Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging.

    PubMed

    Sogani, Julie; Morris, Elizabeth A; Kaplan, Jennifer B; D'Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S; Jochelson, Maxine S

    2017-01-01

    Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material-enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board-approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%-76%) and MR imaging (69%-76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55-0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA

  18. Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging

    PubMed Central

    Morris, Elizabeth A.; Kaplan, Jennifer B.; D’Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S.

    2017-01-01

    Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material–enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board–approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%–76%) and MR imaging (69%–76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55–0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images

  19. Simulation of digital mammography images

    NASA Astrophysics Data System (ADS)

    Workman, Adam

    2005-04-01

    A number of different technologies are available for digital mammography. However, it is not clear how differences in the physical performance aspects of the different imaging technologies affect clinical performance. Randomised controlled trials provide a means of gaining information on clinical performance however do not provide direct comparison of the different digital imaging technologies. This work describes a method of simulating the performance of different digital mammography systems. The method involves modifying the imaging performance parameters of images from a small field of view (SFDM), high resolution digital imaging system used for spot imaging. Under normal operating conditions this system produces images with higher signal-to-noise ratio (SNR) over a wide spatial frequency range than current full field digital mammography (FFDM) systems. The SFDM images can be 'degraded" by computer processing to simulate the characteristics of a FFDM system. Initial work characterised the physical performance (MTF, NPS) of the SFDM detector and developed a model and method for simulating signal transfer and noise properties of a FFDM system. It was found that the SNR properties of the simulated FFDM images were very similar to those measured from an actual FFDM system verifying the methodology used. The application of this technique to clinical images from the small field system will allow the clinical performance of different FFDM systems to be simulated and directly compared using the same clinical image datasets.

  20. Effects of a risk-based online mammography intervention on accuracy of perceived risk and mammography intentions.

    PubMed

    Seitz, Holli H; Gibson, Laura; Skubisz, Christine; Forquer, Heather; Mello, Susan; Schapira, Marilyn M; Armstrong, Katrina; Cappella, Joseph N

    2016-10-01

    This experiment tested the effects of an individualized risk-based online mammography decision intervention. The intervention employs exemplification theory and the Elaboration Likelihood Model of persuasion to improve the match between breast cancer risk and mammography intentions. 2918 women ages 35-49 were stratified into two levels of 10-year breast cancer risk (<1.5%; ≥1.5%) then randomly assigned to one of eight conditions: two comparison conditions and six risk-based intervention conditions that varied according to a 2 (amount of content: brief vs. extended) x 3 (format: expository vs. untailored exemplar [example case] vs. tailored exemplar) design. Outcomes included mammography intentions and accuracy of perceived breast cancer risk. Risk-based intervention conditions improved the match between objective risk estimates and perceived risk, especially for high-numeracy women with a 10-year breast cancer risk ≤1.5%. For women with a risk≤1.5%, exemplars improved accuracy of perceived risk and all risk-based interventions increased intentions to wait until age 50 to screen. A risk-based mammography intervention improved accuracy of perceived risk and the match between objective risk estimates and mammography intentions. Interventions could be applied in online or clinical settings to help women understand risk and make mammography decisions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Effects of a Risk-based Online Mammography Intervention on Accuracy of Perceived Risk and Mammography Intentions

    PubMed Central

    Seitz, Holli H.; Gibson, Laura; Skubisz, Christine; Forquer, Heather; Mello, Susan; Schapira, Marilyn M.; Armstrong, Katrina; Cappella, Joseph N.

    2016-01-01

    Objective This experiment tested the effects of an individualized risk-based online mammography decision intervention. The intervention employs exemplification theory and the Elaboration Likelihood Model of persuasion to improve the match between breast cancer risk and mammography intentions. Methods 2,918 women ages 35-49 were stratified into two levels of 10-year breast cancer risk (< 1.5%; ≥ 1.5%) then randomly assigned to one of eight conditions: two comparison conditions and six risk-based intervention conditions that varied according to a 2 (amount of content: brief vs. extended) × 3 (format: expository vs. untailored exemplar [example case] vs. tailored exemplar) design. Outcomes included mammography intentions and accuracy of perceived breast cancer risk. Results Risk-based intervention conditions improved the match between objective risk estimates and perceived risk, especially for high-numeracy women with a 10-year breast cancer risk <1.5%. For women with a risk < 1.5%, exemplars improved accuracy of perceived risk and all risk-based interventions increased intentions to wait until age 50 to screen. Conclusion A risk-based mammography intervention improved accuracy of perceived risk and the match between objective risk estimates and mammography intentions. Practice Implications Interventions could be applied in online or clinical settings to help women understand risk and make mammography decisions. PMID:27178707

  2. Contrast-enhanced Spectral Mammography: Technique, Indications, and Clinical Applications.

    PubMed

    Bhimani, Chandni; Matta, Danielle; Roth, Robyn G; Liao, Lydia; Tinney, Elizabeth; Brill, Kristin; Germaine, Pauline

    2017-01-01

    Contrast-enhanced spectral mammography (CESM) combines the benefits of full field digital mammography with the concept of tumor angiogenesis. Technique and practical applications of CESM are discussed. An overview of the technique is followed by a demonstration of practical applications of CESM in our practice. We have successfully implemented CESM into our practice as a screening, diagnostic, staging, and treatment response tool. It is important to understand the technique of CESM and how to incorporate it into practice. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Radiation exposure of contrast-enhanced spectral mammography compared with full-field digital mammography.

    PubMed

    Jeukens, Cécile R L P N; Lalji, Ulrich C; Meijer, Eduard; Bakija, Betina; Theunissen, Robin; Wildberger, Joachim E; Lobbes, Marc B I

    2014-10-01

    Contrast-enhanced spectral mammography (CESM) shows promising initial results but comes at the cost of increased dose as compared with full-field digital mammography (FFDM). We aimed to quantitatively assess the dose increase of CESM in comparison with FFDM. Radiation exposure-related data (such as kilovoltage, compressed breast thickness, glandularity, entrance skin air kerma (ESAK), and average glandular dose (AGD) were retrieved for 47 CESM and 715 FFDM patients. All examinations were performed on 1 mammography unit. Radiation dose values reported by the unit were validated by phantom measurements. Descriptive statistics of the patient data were generated using a statistical software package. Dose values reported by the mammography unit were in good qualitative agreement with those of phantom measurements. Mean ESAK was 10.5 mGy for a CESM exposure and 7.46 mGy for an FFDM exposure. Mean AGD for a CESM exposure was 2.80 mGy and 1.55 mGy for an FFDM exposure. Compared with our institutional FFDM, the AGD of a single CESM exposure is increased by 1.25 mGy (+81%), whereas ESAK is increased by 3.07 mGy (+41%). Dose values of both techniques meet the recommendations for maximum dose in mammography.

  4. Towards in vivo TLD dosimetry in mammography.

    PubMed

    Warren-Forward, H M; Duggan, L

    2004-05-01

    While phantoms are used for quality control assessment of the mammography unit, in vivo dose measurements are necessary to account for the variation in size and composition of the female breast. The use of thermoluminescent dosimeters (TLDs) in mammography has been limited due to TLD visibility. The aim of this current investigation was to access the suitability of a paper-thin LiF:Mg,Cu,P TLD (GR-200F) for in vivo dosimetric mammography measurements. The visibility of GR-200F has been directly compared with LiF:Mg,Cu,P TLDs (GR-200A) using a number of commercially available phantoms. The phantoms of thickness 2-5 cm were imaged over the range of tube potentials (24-28 kVp) used clinically. Both types of TLD were placed on the surface of the phantoms allowing assessment of visibility, entrance surface dose (ESD) and field homogeneity. In vivo assessment of ESD and visibility was also carried out on a volunteer undergoing a routine mammography examination. The positions of the GR-200F TLDs were not identified either on the image of the Leeds TOR(MAM) phantom or the patient mammograms. The average ESD for the Leeds phantom was 8.8 mGy, while the patient ESD was 13 mGy. It is now possible to perform in vivo measurements with the potential of increasing the accuracy of the doses measured for women that do not conform to a standard breast thickness or density.

  5. Differential effects on socioeconomic groups of modelling the location of mammography screening clinics using Geographic Information Systems.

    PubMed

    Hyndman, J C; Holman, C D

    2000-06-01

    To evaluate spatial access to mammography clinics and to investigate whether relocating clinics can improve global access. To determine whether any change in access is distributed equitably between different social groups. The study was undertaken in Perth, Western Australia in 1996. It was an analysis of travel distances to mammography clinics, comparing distances to the pattern of existing clinics and modelled relocated clinics. The study population was the 151,162 women aged 40-64 years resident in Perth in 1991. Overall travel distances to the existing clinics was reduced by 14% when a GIS system was used to relocate them so as to minimise the travel distance for all women. The travel distance of the most disadvantaged groups fell by 2% and by 24% for the least disadvantaged group. GIS modelling can be used to advantage to evaluate potential locations for screening clinics that improve the access for the target population, however global analysis should be supplemented by analysis of special groups to ensure that no group is disadvantaged by the proposal. If new technology is not used to evaluate the placement of health services, population travel distances may be greater than necessary, with possible impacts on attendance rates.

  6. Time for a re-evaluation of mammography in the young? Results of an audit of mammography in women younger than 40 in a resource restricted environment.

    PubMed

    Taylor, Liezel; Basro, Sarinah; Apffelstaedt, Justus P; Baatjes, Karin

    2011-08-01

    Mammography in younger women is considered to be of limited value. In a resource restricted environment without access to magnetic resonance imaging (MRI) and with a high incidence of breast cancer in the young, mammography remains an important diagnostic tool. Recent technical advances and better regulation of mammography make a reassessment of its value in these conditions necessary. Data of all the mammograms performed at a tertiary hospital and private breast clinic between January 2003 and July 2009 in women less than 40 years of age were collected. Indications were the presence of a mass, follow-up after primary cancer therapy, and screening for patients perceived at high risk due to a family history or the presence of atypical hyperplasia. Data acquired were as follows: Demographics, prior breast surgery, indication for mammography, outcome of mammography, diagnostic procedures, and their results. Of 2,167 mammograms, 393 were performed for a palpable mass, diagnostic mammography. In these, the overall cancer detection rate was 40%. If the mammography was reported as breast imaging reporting and data system (BIRADS(®)) 5 versus BIRADS(®) 3 and 4 versus BIRADS(®) 1 and 2, a final diagnosis of malignancy was established in 96, 48, and 5%, respectively. Of 367 mammograms done for the follow-up after primary treatment of breast cancer, seven cancers were diagnosed for a detection rate of 1.9%. Of 1,312 mammograms performed for screening, the recall rate was 4%; the biopsy rate 2%, and the cancer diagnosis rate 3/1,000 examinations. In contrast to past series, this series has shown that recent advances in mammography have made it a useful tool in the management of breast problems in young women, notably in a resource-restricted environment. Women for screening should be selected carefully.

  7. Dual-energy contrast-enhanced digital mammography: initial clinical results of a multireader, multicase study

    PubMed Central

    2012-01-01

    Introduction The purpose of this study was to compare the diagnostic accuracy of dual-energy contrast-enhanced digital mammography (CEDM) as an adjunct to mammography (MX) ± ultrasonography (US) with the diagnostic accuracy of MX ± US alone. Methods One hundred ten consenting women with 148 breast lesions (84 malignant, 64 benign) underwent two-view dual-energy CEDM in addition to MX and US using a specially modified digital mammography system (Senographe DS, GE Healthcare). Reference standard was histology for 138 lesions and follow-up for 12 lesions. Six radiologists from 4 institutions interpreted the images using high-resolution softcopy workstations. Confidence of presence (5-point scale), probability of cancer (7-point scale), and BI-RADS scores were evaluated for each finding. Sensitivity, specificity and ROC curve areas were estimated for each reader and overall. Visibility of findings on MX ± CEDM and MX ± US was evaluated with a Likert scale. Results The average per-lesion sensitivity across all readers was significantly higher for MX ± US ± CEDM than for MX ± US (0.78 vs. 0.71 using BIRADS, p = 0.006). All readers improved their clinical performance and the average area under the ROC curve was significantly superior for MX ± US ± CEDM than for MX ± US ((0.87 vs 0.83, p = 0.045). Finding visibility was similar or better on MX ± CEDM than MX ± US in 80% of cases. Conclusions Dual-energy contrast-enhanced digital mammography as an adjunct to MX ± US improves diagnostic accuracy compared to MX ± US alone. Addition of iodinated contrast agent to MX facilitates the visualization of breast lesions. PMID:22697607

  8. Contrast-enhanced spectral mammography: Does mammography provide additional clinical benefits or can some radiation exposure be avoided?

    PubMed

    Fallenberg, Eva Maria; Dromain, Clarisse; Diekmann, Felix; Renz, Diane M; Amer, Heba; Ingold-Heppner, Barbara; Neumann, Avidan U; Winzer, Klaus J; Bick, Ulrich; Hamm, Bernd; Engelken, Florian

    2014-07-01

    The purpose of this study was to compare contrast-enhanced spectral mammography (CESM) with mammography (MG) and combined CESM + MG in terms of detection and size estimation of histologically proven breast cancers in order to assess the potential to reduce radiation exposure. A total of 118 patients underwent MG and CESM and had final histological results. CESM was performed as a bilateral examination starting 2 min after injection of iodinated contrast medium. Three independent blinded radiologists read the CESM, MG, and CESM + MG images with an interval of at least 4 weeks to avoid case memorization. Sensitivity and size measurement correlation and differences were calculated, average glandular dose (AGD) levels were compared, and breast densities were reported. Fisher's exact and Wilcoxon tests were performed. A total of 107 imaging pairs were available for analysis. Densities were ACR1: 2, ACR2: 45, ACR3: 42, and ACR4: 18. Mean AGD was 1.89 mGy for CESM alone, 1.78 mGy for MG, and 3.67 mGy for the combination. In very dense breasts, AGD of CESM was significantly lower than MG. Sensitivity across readers was 77.9 % for MG alone, 94.7 % for CESM, and 95 % for CESM + MG. Average tumor size measurement error compared to postsurgical pathology was -0.6 mm for MG, +0.6 mm for CESM, and +4.5 mm for CESM + MG (p < 0.001 for CESM + MG vs. both modalities). CESM alone has the same sensitivity and better size assessment as CESM + MG and was significantly better than MG with only 6.2 % increase in AGD. The combination of CESM + MG led to systematic size overestimation. When a CESM examination is planned, additional MG can be avoided, with the possibility of saving up to 61 % of radiation dose, especially in patients with dense breasts.

  9. The Future of Contrast-Enhanced Mammography.

    PubMed

    Covington, Matthew F; Pizzitola, Victor J; Lorans, Roxanne; Pockaj, Barbara A; Northfelt, Donald W; Appleton, Catherine M; Patel, Bhavika K

    2018-02-01

    The purpose of this article is to discuss facilitators of and barriers to future implementation of contrast-enhanced mammography (CEM) in the United States. CEM provides low-energy 2D mammographic images analogous to digital mammography and contrast-enhanced recombined images that allow assessment of neovascularity similar to that offered by MRI. The utilization of CEM in the United States is currently low but could increase rapidly given the many potential indications for its clinical use.

  10. Mammography

    MedlinePlus

    ... Prior Mammograms Helps Radiologists Detect Breast Cancer MammographySavesLives.org A general information resource on breast imaging from ... doctors: Breast Density and Breast Cancer Screening RTAnswers.org Radiation Therapy for Breast Cancer MedLinePlus Mammography top ...

  11. Improving mammography screening among the medically underserved.

    PubMed

    Davis, Terry C; Rademaker, Alfred; Bennett, Charles L; Wolf, Michael S; Carias, Edson; Reynolds, Cristalyn; Liu, Dachao; Arnold, Connie L

    2014-04-01

    We evaluated the effectiveness and cost-effectiveness of alternative interventions designed to promote mammography in safety-net settings. A three-arm, quasi-experimental evaluation was conducted among eight federally qualified health clinics in predominately rural Louisiana. Mammography screening efforts included: 1) enhanced care, 2) health literacy-informed education of patients, and 3) education plus nurse support. Outcomes included mammography screening completion within 6 months and incremental cost-effectiveness. Overall, 1,181 female patients ages 40 and over who were eligible for routine mammography were recruited. Baseline screening rates were < 10%. Post intervention screening rates were 55.7% with enhanced care, 51.8% with health literacy-informed education and 65.8% with education and nurse support. After adjusting for race, marital status, self-efficacy and literacy, patients receiving health-literacy informed education were not more likely to complete mammographic screening than those receiving enhanced care; those additionally receiving nurse support were 1.37-fold more likely to complete mammographic screening than those receiving the brief education (95% Confidence Interval 1.08-1.74, p = 0.01). The incremental cost per additional women screened was $2,457 for literacy-informed education with nurse support over literacy-informed education alone. Mammography rates were increased substantially over existing baseline rates in all three arms with the educational initiative, with nurse support and follow-up being the most effective option. However, it is not likely to be cost-effective or affordable in resource-limited clinics.

  12. Mammography Clinical Image Quality and the False Positive Rate in a Canadian Breast Cancer Screening Program.

    PubMed

    Guertin, Marie-Hélène; Théberge, Isabelle; Zomahoun, Hervé Tchala Vignon; Dufresne, Michel-Pierre; Pelletier, Éric; Brisson, Jacques

    2018-05-01

    The study sought to determine if mammography quality is associated with the false positive (FP) rate in the Quebec breast cancer screening program in 2004 and 2005. Mammography quality of a random sample of screen-film mammograms was evaluated by an expert radiologist following the criteria of the Canadian Association of Radiologists. For each screening examination, scores ranging from 1 (poor quality) to 5 (excellent quality) were attributed for positioning, compression, contrast, exposure level, sharpness, and artifacts. A final overall quality score (lower or higher) was also given. Poisson regression models with robust estimation of variance and adjusted for potential confounding factors were used to assess associations of mammography quality with the FP rate. Among 1,209 women without cancer, there were 104 (8.6%) FPs. Lower overall mammography quality is associated with an increase in the FP rate (risk ratio [RR], 1.4; 95% confidence interval [CI], 1.0-2.1; P = .07) but this increase was not statistically significant. Artifacts were associated with an increase in the FP rate (RR, 2.1; 95% CI, 1.3-3.3; P = .01) whereas lower quality of exposure level was related to a reduction of the FP rate (RR, 0.4; 95% CI, 0.1-1.0; P = .01). Lower quality scores for all other quality attributes were related to a nonstatistically significant increase in the FP rate of 10%-30%. Artifacts can have a substantial effect on the FP rate. The effect of overall mammography quality on the FP rate may also be substantial and needs to be clarified. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  13. Mammography status using patient self-reports and computerized radiology database.

    PubMed

    Thompson, B; Taylor, V; Goldberg, H; Mullen, M

    1999-10-01

    This study sought to compare self-reported mammography use of low-income women utilizing an inner-city public hospital with a computerized hospital database for tracking mammography use. A survey of all age-eligible women using the hospital's internal medicine clinic was done; responses were matched with the radiology database. We examined concordance among the two data sources. Concordance between self-report and the database was high (82%) when using "ever had a mammogram at the hospital," but low (58%) when comparing self-reported last mammogram with the information contained in the database. Disagreements existed between self-reports and the database. Because we sought to ensure that women would know exactly what a mammogram entailed by including a picture of a woman having a mammogram, it is possible that women's responses were accurate, leading to concerns that discrepancies might be present in the database. Physicians and staff must ensure that they understand the full history of a woman's experience with mammography before recommending for or against the procedure.

  14. Stepped-Care, Community Clinic Interventions to Promote Mammography Use among Low-Income Rural African American Women

    ERIC Educational Resources Information Center

    West, Delia Smith; Greene, Paul; Pulley, LeaVonne; Kratt, Polly; Gore, Stacy; Weiss, Heidi; Siegfried, Nicole

    2004-01-01

    Few studies have investigated community clinic-based interventions to promote mammography screening among rural African American women. This study randomized older low-income rural African American women who had not participated in screening in the previous 2 years to a theory-based, personalized letter or usual care; no group differences in…

  15. Use of a photoessay to teach low-income African American women about mammography.

    PubMed

    Paskett, E D; Tatum, C; Wilson, A; Dignan, M; Velez, R

    1996-01-01

    Although incidence rates of breast cancer are lower among African American women than white women, mortality rates among African American women are higher, especially for women of lower socioeconomic levels. Reasons for this situation include the lesser use of breast cancer screening examinations by low-income, primarily African American women, late stage of diagnosis, and delays in treatment. As part of community outreach and public health clinic inreach programs for the Forsyth County Cancer Screening Project, approximately 908 African American women who reside in low-income housing communities were targeted for educational efforts related to breast cancer screening. Early in the project, it was discovered that many of the women were unfamiliar with mammography and had very little awareness of how the entire examination was conducted. This low level of knowledge was particularly important because it was a barrier for obtaining regular mammography. A photoessay depicting the process of getting a mammogram was developed and used in community outreach efforts in three formats: in educational classes, as a display in the housing communities, and in physicians' offices. The acceptability of this photoessay to communicate knowledge of and reduce fears about mammography was assessed through evaluation surveys in interviews with a sample of 47 women from the target population. Overall, these women liked the photoessay and felt that it provided knowledge about mammography and reduced fears associated with anticipating mammography. Strategies such as this may be ideal to communicate important information about cancer prevention and control in low-literacy populations.

  16. Mammography Use Among Medicare Beneficiaries After Elimination of Cost Sharing.

    PubMed

    Sabatino, Susan A; Thompson, Trevor D; Guy, Gery P; de Moor, Janet S; Tangka, Florence K

    2016-04-01

    We examined mammography use before and after Medicare eliminated cost sharing for screening mammography in January 2011. Using National Health Interview Survey data, we examined changes in mammography use between 2010 and 2013 among Medicare beneficiaries aged 65-74 years. Logistic regression and predictive margins were used to examine changes in use after adjusting for covariates. In 2013, 74.7% of women reported a mammogram within 2 years, a 3.5 percentage point increase (95% confidence interval, -0.3, 7.2) compared with 2010. Increases occurred among women aged 65-69 years, unmarried women, and women with usual sources of care and 2-5 physician visits in the prior year. After adjustment, mammography use increased in 2013 versus 2010 (74.8% vs. 71.3%, P=0.039). Interactions between year and income, insurance, race, or ethnicity were not significant. There was a modest increase in mammography use from 2010 to 2013 among Medicare beneficiaries aged 65-74 years, possibly consistent with an effect of eliminating Medicare cost sharing during this time. Findings suggest that eliminating cost sharing might increase use of recommended screening services.

  17. Screening Ultrasound as an Adjunct to Mammography in Women with Mammographically Dense Breasts

    PubMed Central

    Scheel, John R.; Lee, Janie M.; Sprague, Brian L.; Lee, Christoph I.; Lehman, Constance D.

    2015-01-01

    There is increasing interest in the potential benefits and harms of screening ultrasound to supplement mammographic screening of women with dense breast tissue. We review the current evidence regarding adjunctive screening breast ultrasound (US) and provide a summary for clinicians who counsel patients with dense breasts. We conducted a comprehensive literature review of published clinical trials and observational cohort studies assessing the efficacy of screening handheld US (HHUS) and automated breast US (ABUS) to supplement mammography among women with dense breasts. From a total of 189 peer-reviewed publications on the performance of screening US, 12 studies were relevant to our analysis. The reporting of breast cancer risk factors varied across studies; however, the study populations tended to be at greater than average risk for developing breast cancer. There is consistent evidence that adjunctive screening US detects more invasive cancers compared to mammography alone, but there is currently no evidence of associated long-term breast cancer mortality reduction. The studies also collectively found that US was associated with an additional 11.7–106.6 biopsies/1,000 examinations (Median 52.2), and detected an additional 0.3–7.7 cancers/1,000 examinations (Median 4.2). The associated number of unnecessary breast biopsies resulting from adjunct US screening exceeds that observed with screening mammography alone by approximately 5-fold. Adjunctive screening with ultrasound should also be considered in the context of screening mammography. It is important for clinicians to be aware that improvements in cancer detection in mammographically dense breasts have been achieved with the transition from film to digital mammography, reducing a limitation of film mammography. Clinicians should discuss breast density as one of several important breast cancer risk factors, consider the potential harms of adjunctive screening, and arrive at a shared decision consistent with

  18. Estimating the relative utility of screening mammography.

    PubMed

    Abbey, Craig K; Eckstein, Miguel P; Boone, John M

    2013-05-01

    The concept of diagnostic utility is a fundamental component of signal detection theory, going back to some of its earliest works. Attaching utility values to the various possible outcomes of a diagnostic test should, in principle, lead to meaningful approaches to evaluating and comparing such systems. However, in many areas of medical imaging, utility is not used because it is presumed to be unknown. In this work, we estimate relative utility (the utility benefit of a detection relative to that of a correct rejection) for screening mammography using its known relation to the slope of a receiver operating characteristic (ROC) curve at the optimal operating point. The approach assumes that the clinical operating point is optimal for the goal of maximizing expected utility and therefore the slope at this point implies a value of relative utility for the diagnostic task, for known disease prevalence. We examine utility estimation in the context of screening mammography using the Digital Mammographic Imaging Screening Trials (DMIST) data. We show how various conditions can influence the estimated relative utility, including characteristics of the rating scale, verification time, probability model, and scope of the ROC curve fit. Relative utility estimates range from 66 to 227. We argue for one particular set of conditions that results in a relative utility estimate of 162 (±14%). This is broadly consistent with values in screening mammography determined previously by other means. At the disease prevalence found in the DMIST study (0.59% at 365-day verification), optimal ROC slopes are near unity, suggesting that utility-based assessments of screening mammography will be similar to those found using Youden's index.

  19. Do mammographic technologists affect radiologists’ diagnostic mammography interpretative performance?

    PubMed Central

    Henderson, Louise M.; Benefield, Thad; Bowling, J. Michael; Durham, Danielle; Marsh, Mary W.; Schroeder, Bruce F.; Yankaskas, Bonnie C.

    2015-01-01

    Objective The purpose of this study was to determine whether the technologist has an effect on the radiologists’ interpretative performance of diagnostic mammography. Materials and Methods Using data from a community based mammography registry from 1994 to 2009, we identified 162,755 diagnostic mammograms interpreted by 286 radiologists and performed by 303 mammographic technologists. We calculated sensitivity, false positive rate, and positive predictive value of biopsy (PPV2) for examinations performed (images taken) by each mammographic technologist, separately for film and digital modalities. We assessed the variability of these performance measures among mammographic technologists, using mixed effects logistic regression and taking into account the clustering of examinations within women, radiologists, and radiology practice. Results Among the 291 technologists performing film examinations, mean sensitivity of the examinations they performed was 83.0% (95% Confidence Interval (CI)=80.8–85.2%), mean false positive rate was 8.5 per 1000 examinations (95%CI: 8.0–9.0%), and mean PPV2 was 27.1% (95%CI: 24.8–29.4). For the 45 technologists performing digital examinations, mean sensitivity of the examinations they performed was 79.6% (95%CI: 73.1–86.2%), mean false positive rate was 8.8 (95%CI: 7.5–10.0%), and mean PPV2 was 23.6% (95%CI: 18.8–28.4%). We found significant variation by technologist in the sensitivity, false positive rate, and PPV2 for film but not digital mammography (p<0.0001 for all 3 film performance measures). Conclusions Our results suggest that the technologist has an influence on radiologists’ performance of diagnostic film mammography but not digital. Future work should examine why this difference by modality exists and determine if similar patterns are observed for screening mammography. PMID:25794085

  20. Measurement of X-ray intensity in mammography by a ferroelectric dosimeter

    NASA Astrophysics Data System (ADS)

    Alter, Albert J.

    2005-07-01

    Each year in the US over 20 million women undergo mammography, a relatively high dose x-ray examination of the breast, which is relatively sensitive to the carcinogenic effect of ionizing radiation. The radiation risk from mammography is usually expressed in terms of mean glandular dose (MGD) which is calculated as the product of measured entrance exposure (ESE) and a dose conversion factor which is a function of anode material, peak tube voltage (23 to 35 kVp), half-value layer, filtration, compressed breast thickness and breast composition. Mammographic units may have anodes made of molybdenum, rhodium or tungsten and filters of molybdenum, rhodium, or aluminum. In order to accommodate all these parameters, multiple extensive tables of conversion factors are required to cover the range of possibilities. Energy fluence and energy imparted are alternative measures of radiation hazard, which have been used in situations where geometry or filtration is unconventional such as computed tomography or fluoroscopy. Unfortunately, at the present there is no way to directly measure these quantities clinically. In radiation therapy applications, calorimetry has been used to measure energy absorbed. A ferroelectric-based detector has been described that measures energy fluence rate (x-ray intensity) for diagnostic x-ray, 50 to 140 kVp, aluminum filtered tungsten spectrum [Carvalho & Alter: IEEE Transactions 44(6) 1997]. This work explores use of ferroelectric detectors to measure energy fluence, energy fluence rate and energy imparted in mammography. A detector interfaced with a laptop computer was developed to allow measurements on clinical units of five different manufactures having targets of molybdenum, rhodium and tungsten and filters of molybdenum, rhodium, and aluminum of various thicknesses. The measurements provide the first values of energy fluence and energy imparted in mammography. These measurements are compared with conventional parameters such as entrance

  1. [New mammography technologies and their impact on radiation dose].

    PubMed

    Chevalier del Rio, M

    2013-12-01

    This article reviews new mammography technologies resulting from advances in digital detectors and processing techniques. Most are just starting to be commercialized or are in the clinical trial phase. The results of clinical trials with the new 2D techniques (contrast-enhanced techniques or stereotactic techniques) show they are useful for diagnosing cancer. However, the greater complexity of the image acquisition process suggests that their use will be limited to particular cases such as inconclusive lesions or women with high risk for developing breast cancer. Among the 3D technologies (breast tomography and breast tomosynthesis), only breast tomosynthesis has been implemented in clinical practice, so it is the only technique for which it is possible to know the sensitivity, specificity, and radiation dose delivered. This article describes the principles underlying the way breast tomosynthesis works and the techniques used for image acquisition and reconstruction. It also summarizes the main results obtained in clinical studies, which generally show that breast tomosynthesis increases the breast cancer detection rate while decreasing the recall rate and number of biopsies taken. The protocol for breast tomosynthesis approved by the Food and Drug Administration (USA) consists of two conventional mammography projections for each breast and two tomosynthesis projections for each breast. This means multiplying the risks of inducing cancer and death associated with 2D mammography by a factor between 2 and 3 (2.6-3.3 and 0.7-0.9 per 100,000 women exposed when 50 years old, respectively). The protocol for breast tomosynthesis examinations is one of the aspects that is essential to determine when including tomosynthesis in screening programs and routine breast imaging. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.

  2. Reproducibility of Mammography Units, Film Processing and Quality Imaging

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique

    2003-09-01

    The purpose of this study was to carry out an exploratory survey of the problems of quality control in mammography and processors units as a diagnosis of the current situation of mammography facilities. Measurements of reproducibility, optical density, optical difference and gamma index are included. Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is a radiographic examination specially designed for detecting breast pathology. We found that the problems of reproducibility of AEC are smaller than the problems of processors units because almost all processors fall outside of the acceptable variation limits and they can affect the mammography quality image and the dose to breast. Only four mammography units agree with the minimum score established by ACR and FDA for the phantom image.

  3. TL dosimetry for quality control of CR mammography imaging systems

    NASA Astrophysics Data System (ADS)

    Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.

    The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.

  4. Predictors of mammography screening among ethnically diverse low-income women.

    PubMed

    Cronan, Terry A; Villalta, Ian; Gottfried, Emily; Vaden, Yavette; Ribas, Mabel; Conway, Terry L

    2008-05-01

    Breast cancer is the second leading cause of cancer deaths among women in the United States. Minority women are less likely to be screened and more likely to die from breast cancer than are Caucasian women. Although some studies have examined ethnic disparities in mammography screening, no study has examined whether there are ethnic disparities among low-income, ethnically diverse women. The present study was designed to determine whether there are ethnic disparities in mammography screening and predictors of screening among low-income African American, Mexican American, and Caucasian women, and to determine whether the disparities and predictors vary across ethnic groups. The participants were 146 low-income women who were Mexican American (32%), African American (31%), or Caucasian (37%). Statistical analyses were performed to assess the relationships between mammography screening during the past 2 years and potential predictors of screening, both within ethnic groups and for the combined sample. The results varied depending on whether analyses combined ethnic groups or were performed within each of the three ethnic groups. It is, therefore, important to examine within-group differences when examining ethnic disparities in predictors of mammography.

  5. MASTOS: Mammography Simulation Tool for design Optimization Studies.

    PubMed

    Spyrou, G; Panayiotakis, G; Tzanakos, G

    2000-01-01

    Mammography is a high quality imaging technique for the detection of breast lesions, which requires dedicated equipment and optimum operation. The design parameters of a mammography unit have to be decided and evaluated before the construction of such a high cost of apparatus. The optimum operational parameters also must be defined well before the real breast examination. MASTOS is a software package, based on Monte Carlo methods, that is designed to be used as a simulation tool in mammography. The input consists of the parameters that have to be specified when using a mammography unit, and also the parameters specifying the shape and composition of the breast phantom. In addition, the input may specify parameters needed in the design of a new mammographic apparatus. The main output of the simulation is a mammographic image and calculations of various factors that describe the image quality. The Monte Carlo simulation code is PC-based and is driven by an outer shell of a graphical user interface. The entire software package is a simulation tool for mammography and can be applied in basic research and/or in training in the fields of medical physics and biomedical engineering as well as in the performance evaluation of new designs of mammography units and in the determination of optimum standards for the operational parameters of a mammography unit.

  6. Perspectives of Mobile Versus Fixed Mammography in Santa Clara County, California: A Focus Group Study.

    PubMed

    Chen, Yi-Ren; Chang-Halpenny, Christine; Kumarasamy, Narmadan A; Venegas, Angela; Braddock Iii, Clarence H

    2016-02-12

    Our aim was to examine underserved women's perceptions on mobile versus fixed mammography in Santa Clara, California through a focus group study.  Research has shown that medically underserved women have higher breast cancer mortality rates correlated with under-screening and a disproportional rate of late-stage diagnosis. The Community Health Partnership in Santa Clara County, California runs the Community Mammography Access Project (CMAP) that targets nearly 20,000 medically underserved women over the age of 40 in the county through the collaborative effort of an existing safety net of healthcare providers. However, little data exists on the advantages or disadvantages of mobile mammography units from the patient perspective.   We assessed underserved women's perspectives on mammography services in Santa Clara County through two focus groups from women screened at mobile or fixed site programs. Patients were recruited from both CMAP clinics and a county hospital, and focus group data were analyzed using content analysis.  We found that women from both the mobile and fixed sites shared similar motivating factors for getting a mammogram. Both groups recognized that screening was uncomfortable but necessary for good health and had positive feedback about their personal physicians. However, mobile participants, in particular, appreciated the atmosphere of mobile screening, reported shorter wait times, and remarked on the good communication from the clinic staff and empathetic treatment they received. However, mobile participants also expressed concern about the quality of films at mobile sites due to delayed initial reading of the films.   Mobile mammography offers a unique opportunity for women of underserved populations to access high satisfaction screenings, and it encourages a model similar to CMAP in other underserved areas. However, emphasis should be placed on providing a warm and welcoming environment for patients and ensuring the quality of

  7. Beyond Mammography: New Frontiers in Breast Cancer Screening

    PubMed Central

    Drukteinis, Jennifer S.; Mooney, Blaise P.; Flowers, Chris I.; Gatenby, Robert A

    2014-01-01

    Breast cancer screening remains a subject of intense and, at times, passionate debate. Mammography has long been the mainstay of breast cancer detection and is the only screening test proven to reduce mortality. Although it remains the gold standard of breast cancer screening, there is increasing awareness of subpopulations of women for whom mammography has reduced sensitivity. Mammography has also undergone increased scrutiny for false positives and excessive biopsies, which increase radiation dose, cost and patient anxiety. In response to these challenges, new technologies for breast cancer screening have been developed, including; low dose mammography; contrast enhanced mammography, tomosynthesis, automated whole breast ultrasound, molecular imaging and MRI. Here we examine some of the current controversies and promising new technologies that may improve detection of breast cancer both in the general population and in high-risk groups, such as women with dense breasts. We propose that optimal breast cancer screening will ultimately require a personalized approach based on metrics of cancer risk with selective application of specific screening technologies best suited to the individual’s age, risk, and breast density. PMID:23561631

  8. Comparative effectiveness of combined digital mammography and tomosynthesis screening for women with dense breasts.

    PubMed

    Lee, Christoph I; Cevik, Mucahit; Alagoz, Oguzhan; Sprague, Brian L; Tosteson, Anna N A; Miglioretti, Diana L; Kerlikowske, Karla; Stout, Natasha K; Jarvik, Jeffrey G; Ramsey, Scott D; Lehman, Constance D

    2015-03-01

    To evaluate the effectiveness of combined biennial digital mammography and tomosynthesis screening, compared with biennial digital mammography screening alone, among women with dense breasts. An established, discrete-event breast cancer simulation model was used to estimate the comparative clinical effectiveness and cost-effectiveness of biennial screening with both digital mammography and tomosynthesis versus digital mammography alone among U.S. women aged 50-74 years with dense breasts from a federal payer perspective and a lifetime horizon. Input values were estimated for test performance, costs, and health state utilities from the National Cancer Institute Breast Cancer Surveillance Consortium, Medicare reimbursement rates, and medical literature. Sensitivity analyses were performed to determine the implications of varying key model parameters, including combined screening sensitivity and specificity, transient utility decrement of diagnostic work-up, and additional cost of tomosynthesis. For the base-case analysis, the incremental cost per quality-adjusted life year gained by adding tomosynthesis to digital mammography screening was $53 893. An additional 0.5 deaths were averted and 405 false-positive findings avoided per 1000 women after 12 rounds of screening. Combined screening remained cost-effective (less than $100 000 per quality-adjusted life year gained) over a wide range of incremental improvements in test performance. Overall, cost-effectiveness was most sensitive to the additional cost of tomosynthesis. Biennial combined digital mammography and tomosynthesis screening for U.S. women aged 50-74 years with dense breasts is likely to be cost-effective if priced appropriately (up to $226 for combined examinations vs $139 for digital mammography alone) and if reported interpretive performance metrics of improved specificity with tomosynthesis are met in routine practice.

  9. [Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer--comparison with film-screen mammography].

    PubMed

    Kitahama, H

    1991-05-25

    The aim of this study is to present efficacy of storage phosphor-based digital mammography (CR-mammography) in diagnosis of breast cancer. Ninety-seven cases with breast cancer including 44 cases less than 2 cm in macroscopic size (t1 cases) were evaluated using storage phosphor-based digital mammography (2000 x 2510 pixels by 10 bits). Abnormal findings on CR-mammography were detected in 86 cases (88.7%) of 97 women with breast cancer. Sensitivity of CR-mammography was 88.7%. It was superior to that of film-screen mammography. On t1 breast cancer cases, sensitivity on CR-mammography was 88.6%. False negative rate in t1 breast cancer cases was reduced by image processing using CR-mammography. To evaluate microcalcifications, CR-mammograms and film-screen mammograms were investigated in 22 cases of breast cancer proven pathologically the existence of microcalcifications and 11 paraffin tissue blocks of breast cancer. CR-mammography was superior to film-screen mammography in recognizing of microcalcifications. As regards the detectability for the number and the shape of microcalcifications, CR-mammography was equivalent to film-screen mammography. Receiver operating characteristic (ROC) analysis by eight observers was performed for CR-mammography and film-screen mammography with 54 breast cancer patients and 54 normal cases. The detectability of abnormal findings of breast cancer on CR-mammography (ROC area = 0.91) was better than that on film-screen mammography (ROC area = 0.88) (p less than 0.05). Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer was discussed and demonstrated in this study.

  10. Sustaining mammography screening among the medically underserved: a follow-up evaluation.

    PubMed

    Davis, Terry C; Arnold, Connie L; Bennett, Charles L; Wolf, Michael S; Liu, Dachao; Rademaker, Alfred

    2015-04-01

    Our previous three-arm comparative effectiveness intervention in community clinic patients who were not up-to-date with screening resulted in mammography rates over 50% in all arms. Our aim was to evaluate the effectiveness and cost-effectiveness of the three interventions on improving biennial screening rates among eligible patients. A three-arm quasi-experimental evaluation was conducted in eight community clinics from 2008 to 2011. Screening efforts included (1) enhanced care: Participants received an in-person recommendation from a research assistant (RA) in year 1, and clinics followed usual clinic protocol for scheduling screening mammograms; (2) education intervention: Participants received education and in-person recommendation from an RA in year 1, and clinics followed usual clinic protocol for scheduling mammograms; or (3) nurse support: A nurse manager provided in-person education and recommendation, scheduled mammograms, and followed up with phone support. In all arms, mammography was offered at no cost to uninsured patients. Of 624 eligible women, biennial mammography within 24-30 months of their previous test was performed for 11.0% of women in the enhanced-care arm, 7.1% in the education- intervention arm, and 48.0% in the nurse-support arm (p<0.0001). The incremental cost was $1,232 per additional woman undergoing screening with nurse support vs. enhanced care and $1,092 with nurse support vs. education. Biennial mammography screening rates were improved by providing nurse support but not with enhanced care or education. However, this approach was not cost-effective.

  11. Contrast-Enhanced Spectral Mammography: Comparison with Conventional Mammography and Histopathology in 152 Women

    PubMed Central

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Rys, Janusz; Reinfuss, Marian

    2014-01-01

    Objective The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. Materials and Methods The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an "iodine" image which outlined contrast up-take in the breast. Results MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p < 0.001). Conclusion CESM may provide higher sensitivity for breast cancer detection and greater diagnostic accuracy than conventional mammography. PMID:25469079

  12. Contrast-enhanced spectral mammography: comparison with conventional mammography and histopathology in 152 women.

    PubMed

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Blecharz, Pawel; Rys, Janusz; Reinfuss, Marian

    2014-01-01

    The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an "iodine" image which outlined contrast up-take in the breast. MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p < 0.001). CESM may provide higher sensitivity for breast cancer detection and greater diagnostic accuracy than conventional mammography.

  13. Family/friend recommendations and mammography intentions: the roles of perceived mammography norms and support

    PubMed Central

    Molina, Yamile; Ornelas, India J.; Doty, Sarah L.; Bishop, Sonia; Beresford, Shirley A. A.; Coronado, Gloria D.

    2015-01-01

    Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography intentions. Theory suggests that family/friend recommendations increase perceived mammography norms (others believe a woman should obtain a mammogram) and support (others will help her obtain a mammogram), which in turn increase mammography intentions and use. We tested these hypotheses with data from the ¡Fortaleza Latina! study, a randomized controlled trial including 539 Latinas in Washington State. Women whose family/friend recommended they get a mammogram within the last year were more likely to report mammography intentions, norms and support. Perceived mammography norms mediated the relationship between family/friend recommendations and intentions, Mediated Effect = 0.38, 95%CI [0.20, 0.61], but not support, Mediated Effect = 0.002, 95%CI [−0.07, 0.07]. Our findings suggest perceived mammography norms are a potential mechanism underlying the effect of family/friend recommendations on mammography use among Latinas. Our findings make an important contribution to theory about the associations of social interactions, perceptions and health behaviors. PMID:26324395

  14. Information Extraction for Clinical Data Mining: A Mammography Case Study

    PubMed Central

    Nassif, Houssam; Woods, Ryan; Burnside, Elizabeth; Ayvaci, Mehmet; Shavlik, Jude; Page, David

    2013-01-01

    Breast cancer is the leading cause of cancer mortality in women between the ages of 15 and 54. During mammography screening, radiologists use a strict lexicon (BI-RADS) to describe and report their findings. Mammography records are then stored in a well-defined database format (NMD). Lately, researchers have applied data mining and machine learning techniques to these databases. They successfully built breast cancer classifiers that can help in early detection of malignancy. However, the validity of these models depends on the quality of the underlying databases. Unfortunately, most databases suffer from inconsistencies, missing data, inter-observer variability and inappropriate term usage. In addition, many databases are not compliant with the NMD format and/or solely consist of text reports. BI-RADS feature extraction from free text and consistency checks between recorded predictive variables and text reports are crucial to addressing this problem. We describe a general scheme for concept information retrieval from free text given a lexicon, and present a BI-RADS features extraction algorithm for clinical data mining. It consists of a syntax analyzer, a concept finder and a negation detector. The syntax analyzer preprocesses the input into individual sentences. The concept finder uses a semantic grammar based on the BI-RADS lexicon and the experts’ input. It parses sentences detecting BI-RADS concepts. Once a concept is located, a lexical scanner checks for negation. Our method can handle multiple latent concepts within the text, filtering out ultrasound concepts. On our dataset, our algorithm achieves 97.7% precision, 95.5% recall and an F1-score of 0.97. It outperforms manual feature extraction at the 5% statistical significance level. PMID:23765123

  15. Information Extraction for Clinical Data Mining: A Mammography Case Study.

    PubMed

    Nassif, Houssam; Woods, Ryan; Burnside, Elizabeth; Ayvaci, Mehmet; Shavlik, Jude; Page, David

    2009-01-01

    Breast cancer is the leading cause of cancer mortality in women between the ages of 15 and 54. During mammography screening, radiologists use a strict lexicon (BI-RADS) to describe and report their findings. Mammography records are then stored in a well-defined database format (NMD). Lately, researchers have applied data mining and machine learning techniques to these databases. They successfully built breast cancer classifiers that can help in early detection of malignancy. However, the validity of these models depends on the quality of the underlying databases. Unfortunately, most databases suffer from inconsistencies, missing data, inter-observer variability and inappropriate term usage. In addition, many databases are not compliant with the NMD format and/or solely consist of text reports. BI-RADS feature extraction from free text and consistency checks between recorded predictive variables and text reports are crucial to addressing this problem. We describe a general scheme for concept information retrieval from free text given a lexicon, and present a BI-RADS features extraction algorithm for clinical data mining. It consists of a syntax analyzer, a concept finder and a negation detector. The syntax analyzer preprocesses the input into individual sentences. The concept finder uses a semantic grammar based on the BI-RADS lexicon and the experts' input. It parses sentences detecting BI-RADS concepts. Once a concept is located, a lexical scanner checks for negation. Our method can handle multiple latent concepts within the text, filtering out ultrasound concepts. On our dataset, our algorithm achieves 97.7% precision, 95.5% recall and an F 1 -score of 0.97. It outperforms manual feature extraction at the 5% statistical significance level.

  16. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size.

    PubMed

    Fallenberg, E M; Dromain, C; Diekmann, F; Engelken, F; Krohn, M; Singh, J M; Ingold-Heppner, B; Winzer, K J; Bick, U; Renz, D M

    2014-01-01

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography (CESM) is slowly being introduced into clinical practice. • Access to breast MRI is limited by availability and lack of reimbursement. • Initial results show a better sensitivity of CESM and MRI than conventional mammography. • CESM showed a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography offers promise, seemingly providing information comparable to MRI.

  17. Family/friend recommendations and mammography intentions: the roles of perceived mammography norms and support.

    PubMed

    Molina, Yamile; Ornelas, India J; Doty, Sarah L; Bishop, Sonia; Beresford, Shirley A A; Coronado, Gloria D

    2015-10-01

    Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography intentions. Theory suggests that family/friend recommendations increase perceived mammography norms (others believe a woman should obtain a mammogram) and support (others will help her obtain a mammogram), which in turn increase mammography intentions and use. We tested these hypotheses with data from the ¡Fortaleza Latina! study, a randomized controlled trial including 539 Latinas in Washington State. Women whose family/friend recommended they get a mammogram within the last year were more likely to report mammography intentions, norms and support. Perceived mammography norms mediated the relationship between family/friend recommendations and intentions, Mediated Effect = 0.38, 95%CI [0.20, 0.61], but not support, Mediated Effect = 0.002, 95%CI [-0.07, 0.07]. Our findings suggest perceived mammography norms are a potential mechanism underlying the effect of family/friend recommendations on mammography use among Latinas. Our findings make an important contribution to theory about the associations of social interactions, perceptions and health behaviors. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. A review of screening mammography participation and utilization in Canada.

    PubMed

    Doyle, G P; Major, D; Chu, C; Stankiewicz, A; Harrison, M L; Pogany, L; Mai, V M; Onysko, J

    2011-09-01

    Participation rate is an important indicator for a screening program's effectiveness; however, the current approach to measuring participation rate in Canada is not comparable with other countries. The objective of this study is to review the measurement of screening mammography participation in Canada, make international comparisons, and propose alternative methods. Canadian breast cancer screening program data for women aged 50 to 69 years screened between 2004 and 2006 were extracted from the Canadian Breast Cancer Screening Database (CBCSD). The fee-for-services (FSS) mammography data (opportunistic screening mammography) were obtained from the provincial ministries of health. Both screening mammography program participation and utilization were examined over 24 and 30 months. Canada's screening participation rate increases from 39.4% for a 24-month cut-off to 43.6% for a 30-month cut-off. The 24-month mammography utilization rate is 63.1% in Canada, and the 30-month utilization rate is 70.4%. Due to the differences in health service delivery among Canadian provinces, both programmatic participation and overall utilization of mammography at 24 months and 30 months should be monitored.

  19. The clinical effectiveness and cost-effectiveness of different surveillance mammography regimens after the treatment for primary breast cancer: systematic reviews registry database analyses and economic evaluation.

    PubMed

    Robertson, C; Arcot Ragupathy, S K; Boachie, C; Dixon, J M; Fraser, C; Hernández, R; Heys, S; Jack, W; Kerr, G R; Lawrence, G; MacLennan, G; Maxwell, A; McGregor, J; Mowatt, G; Pinder, S; Ternent, L; Thomas, R E; Vale, L; Wilson, R; Zhu, S; Gilbert, F J

    2011-09-01

    Following primary breast cancer treatment, the early detection of ipsilateral breast tumour recurrence (IBTR) or ipsilateral secondary cancer in the treated breast and detection of new primary cancers in the contralateral breast is beneficial for survival. Surveillance mammography is used to detect these cancers, but the optimal frequency of surveillance and the length of follow-up are unclear. To identify feasible management strategies for surveillance and follow-up of women after treatment for primary breast cancer in a UK setting, and to determine the effectiveness and cost-effectiveness of differing regimens. A survey of UK breast surgeons and radiologists to identify current surveillance mammography regimens and inform feasible alternatives; two discrete systematic reviews of evidence published from 1990 to mid 2009 to determine (i) the clinical effectiveness and cost-effectiveness of differing surveillance mammography regimens for patient health outcomes and (ii) the test performance of surveillance mammography in the detection of IBTR and metachronous contralateral breast cancer (MCBC); statistical analysis of individual patient data (West Midlands Cancer Intelligence Unit Breast Cancer Registry and Edinburgh data sets); and economic modelling using the systematic reviews results, existing data sets, and focused searches for specific data analysis to determine the effectiveness and cost-utility of differing surveillance regimens. The majority of survey respondents initiate surveillance mammography 12 months after breast-conserving surgery (BCS) (87%) or mastectomy (79%). Annual surveillance mammography was most commonly reported for women after BCS or after mastectomy (72% and 53%, respectively). Most (74%) discharge women from surveillance mammography, most frequently 10 years after surgery. The majority (82%) discharge from clinical follow-up, most frequently at 5 years. Combining initiation, frequency and duration of surveillance mammography resulted in

  20. Clinical breast examination and mammography: inequalities in Southern and Northeast Brazilian regions.

    PubMed

    Borges, Zaida da Silva; Wehrmeister, Fernando César; Gomes, Ana Paula; Gonçalves, Helen

    2016-03-01

    To evaluate the prevalence and associated factors of doing clinical breast examinations (CBE) and mammogram (MMG) in the Southern and Northeast Brazilian regions, focusing on some social inequalities. This is a cross-sectional study using data from the 2008 National Household Sampling Survey (PNAD). We evaluated the prevalence of CBE during the last year and of the MMG in the last two years, which were analyzed based on demographic (age, skin color, and marital status) and socioeconomic (income and schooling) variables. Gross and adjusted prevalence ratios were obtained using Poisson regression models. All analyses were stratified by region. The sample comprised 27,718 women aged 40 to 69 years. Less than a half of the women followed the recommendation of annual CBE performance in both the regions. The MMG prevalence during the last two years was 58.6 and 45.5% for the Southern and Northeast regions, respectively. More than a quarter of the women had never had a MMG (26.5% in the Southern and 40.6% in the Northeast regions). Not having performed both examinations was almost two times higher in the Northeast region (29.7%) when compared with the Southern (15.9%). The risk for not having performed both examinations was greater among nonwhite women, aged 60 to 69 years, with lower schooling level and family income. Important inequalities were seen between the Southern and Northeast regions for CBE and MMG. Health public policies should prioritize the most vulnerable groups to reduce these inequalities.

  1. Si-strip photon counting detectors for contrast-enhanced spectral mammography

    NASA Astrophysics Data System (ADS)

    Chen, Buxin; Reiser, Ingrid; Wessel, Jan C.; Malakhov, Nail; Wawrzyniak, Gregor; Hartsough, Neal E.; Gandhi, Thulasi; Chen, Chin-Tu; Iwanczyk, Jan S.; Barber, William C.

    2015-08-01

    We report on the development of silicon strip detectors for energy-resolved clinical mammography. Typically, X-ray integrating detectors based on scintillating cesium iodide CsI(Tl) or amorphous selenium (a-Se) are used in most commercial systems. Recently, mammography instrumentation has been introduced based on photon counting Si strip detectors. The required performance for mammography in terms of the output count rate, spatial resolution, and dynamic range must be obtained with sufficient field of view for the application, thus requiring the tiling of pixel arrays and particular scanning techniques. Room temperature Si strip detector, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel, provided that the sensors are designed for rapid signal formation across the X-ray energy ranges of the application. We present our methods and results from the optimization of Si-strip detectors for contrast enhanced spectral mammography. We describe the method being developed for quantifying iodine contrast using the energy-resolved detector with fixed thresholds. We demonstrate the feasibility of the method by scanning an iodine phantom with clinically relevant contrast levels.

  2. Sustaining Mammography Screening Among the Medically Underserved: A Follow-Up Evaluation

    PubMed Central

    Arnold, Connie L.; Bennett, Charles L.; Wolf, Michael S.; Liu, Dachao; Rademaker, Alfred

    2015-01-01

    Abstract Background: Our previous three-arm comparative effectiveness intervention in community clinic patients who were not up-to-date with screening resulted in mammography rates over 50% in all arms. Objective: Our aim was to evaluate the effectiveness and cost-effectiveness of the three interventions on improving biennial screening rates among eligible patients. Methods: A three-arm quasi-experimental evaluation was conducted in eight community clinics from 2008 to 2011. Screening efforts included (1) enhanced care: Participants received an in-person recommendation from a research assistant (RA) in year 1, and clinics followed usual clinic protocol for scheduling screening mammograms; (2) education intervention: Participants received education and in-person recommendation from an RA in year 1, and clinics followed usual clinic protocol for scheduling mammograms; or (3) nurse support: A nurse manager provided in-person education and recommendation, scheduled mammograms, and followed up with phone support. In all arms, mammography was offered at no cost to uninsured patients. Results: Of 624 eligible women, biennial mammography within 24–30 months of their previous test was performed for 11.0% of women in the enhanced-care arm, 7.1% in the education- intervention arm, and 48.0% in the nurse-support arm (p<0.0001). The incremental cost was $1,232 per additional woman undergoing screening with nurse support vs. enhanced care and $1,092 with nurse support vs. education. Conclusions: Biennial mammography screening rates were improved by providing nurse support but not with enhanced care or education. However, this approach was not cost-effective. PMID:25692910

  3. Digital Mammography with a Mosaic of CCD-Arrays

    NASA Technical Reports Server (NTRS)

    Jalink, Antony, Jr. (Inventor); McAdoo, James A. (Inventor)

    1996-01-01

    The present invention relates generally to a mammography device and method and more particularly to a novel digital mammography device and method to detect microcalcifications of precancerous tissue. A digital mammography device uses a mosaic of electronic digital imaging arrays to scan an x-ray image. The mosaic of arrays is repositioned several times to expose different portions of the image, until the entire image is scanned. The data generated by the arrays during each exposure is stored in a computer. After the final exposure, the computer combines data of the several partial images to produce a composite of the original x-ray image. An aperture plate is used to reduce scatter and the overall exposure of the patient to x-rays. The novelty of this invention is that it provides a digital mammography device with large field coverage, high spatial resolution, scatter rejection, excellent contrast characteristics and lesion detectability under clinical conditions. This device also shields the patient from excessive radiation, can detect extremely small calcifications and allows manipulation and storage of the image.

  4. Optical tomography as adjunct to x-ray mammography: methods and results

    NASA Astrophysics Data System (ADS)

    Khayat, Mario; Ichalalene, Zahia; Mincu, Niculae; Leblond, Fredéric; Guilman, Olga; Djeziri, Salim

    2007-02-01

    Recent years have seen significant efforts deployed to apply optical imaging techniques in clinical indications. Optical mammography as an adjunct to X-ray mammography is one such application. 3D optical mammography relies on the sensitivity of near-infrared light to endogenous breast chromophores in order to generate in vivo functional views of the breast. This work presents prospective tissue characterization results from a multi-site clinical study targeting optical tomography as an adjunct to conventional mammography. A 2 nd -generation multi-wavelength time-domain acquisition system was used to scan a wide population of women presenting normal or suspicious X-ray mammograms. Application specific algorithms based on a diffusive model of light transport were used to quantify the breast's optical properties and derive 3D images of physiological indices. Using histopathological findings as a gold standard, results confirm that optically derived parameters provide statistically significant discrimination between malignant and benign tissue in wide population of subjects. The methodology developed for case reviews, lesion delineation and characterization allows for better translation of the optical data to the more traditional x-ray paradigm while maintaining efficacy. They also point to the need for guidelines that facilitate correlation of optical data if those results are to be confirmed in a clinical setting.

  5. Screening mammography--early detection or over-diagnosis? Contribution from Australian data.

    PubMed

    Bell, R J

    2014-12-01

    The aim of this review was to examine the benefits and harms of organized screening mammography, with particular reference to data from Australia. Published literature was examined relating to the impact of screening mammography on breast cancer-specific mortality, the trends in use of adjuvant treatments for breast cancer, the effectiveness of adjuvant treatment in terms of breast cancer-specific mortality, the impact of breast cancer treatment on non-breast cancer mortality and the magnitude of the issue of over-diagnosis. Most of the recent reduction in breast cancer-specific mortality is explained by use of adjuvant therapy rather than screening mammography. The impact of screening mammography in countries where women present with early disease and have access to adjuvant treatment is modest. There is a wide range of estimates for the magnitude of over-diagnosis. All-cause mortality (rather than breast cancer-specific mortality) should be used when assessing the impact of mammographic screening as otherwise the harm of breast cancer treatment in women who are over-diagnosed will be missed. The benefits and harms of screening mammography are finely balanced. The impact of screening mammography is at best neutral but may result in overall harm. Women should be informed of the issue of over-diagnosis. It is time to review whether organized mammographic screening programs should continue.

  6. Determination of the anxiety level of women who present for mammography.

    PubMed

    Bölükbaş, Nurgül; Erbil, Nülüfer; Kahraman, Azize Nuran

    2010-01-01

    This paper was to examine the role of anxiety in mammography screening. Breast cancer screening with mammography has been shown to be effective for preventing breast cancer death. However mammography screening can be harmful to women. One of the major problems is anxiety or lack of peace of mind in mammography screening. This study was conducted between November 3, 2007, and December 30, 2007, in Ordu Maternity and Childbirth Hospital. 93 women participated in the study. A 23-item questionnaire and the 20-item State Anxiety Inventory, developed by Spielberger et al. were completed by the participants. All numerical values were given as average ± standard deviation; p<0.05 was accepted for level of significance. The average age of the participants was 47.83 ± 7.50, the average age at marriage was 20.03 ± 4.18, the average birth number 2.91 ± 1.21, and the average age at menopause was 46.10 ± 4.70. The average anxiety level was found to be 46.20 ± 4.9. Significant differences (p<0.05) were found between education level, age at marriage, status of doing breast self examination, status of having a mammography for a breast-related complaint, and the number of mammograms done. It was determined that women who had mammography had a moderate level of anxiety.

  7. The relationship between breast cancer anxiety and mammography: experiential avoidance as a moderator.

    PubMed

    Miller, Sarah J; O'Hea, Erin L; Lerner, Jennifer Block; Moon, Simon; Foran-Tuller, Kelly A

    2011-10-01

    Although mammography can aid in the early detection and prevention of breast cancer, many women do not receive annual mammograms. It remains unclear whether anxiety about breast cancer inhibits or promotes mammography rates. The way in which women regulate their anxiety (ie, level of experiential avoidance) may play a role in predicting mammography adherence. A community sample of women (N = 84) completed a questionnaire which assessed mammography rates, experiential avoidance, and breast cancer anxiety. The results suggest that, while controlling for breast cancer anxiety, experiential avoidance (β = .31, p < .01) significantly predicted mammography rates. When examining experiential avoidance as a moderator, a multiple regression analysis approached significance (R2 Δ = .04, p = .07), suggesting that a woman's level of experiential avoidance influences the relationship between anxiety and mammography. These findings will help enable health care practitioners to better identify women at risk of non-adherence to mammography recommendations.

  8. Breast screening using 2D-mammography or integrating digital breast tomosynthesis (3D-mammography) for single-reading or double-reading--evidence to guide future screening strategies.

    PubMed

    Houssami, Nehmat; Macaskill, Petra; Bernardi, Daniela; Caumo, Francesca; Pellegrini, Marco; Brunelli, Silvia; Tuttobene, Paola; Bricolo, Paola; Fantò, Carmine; Valentini, Marvi; Ciatto, Stefano

    2014-07-01

    We compared detection measures for breast screening strategies comprising single-reading or double-reading using standard 2D-mammography or 2D/3D-mammography, based on the 'screening with tomosynthesis or standard mammography' (STORM) trial. STORM prospectively examined screen-reading in two sequential phases, 2D-mammography alone and integrated 2D/3D-mammography, in asymptomatic women participating in Trento and Verona (Northern Italy) population-based screening services. Outcomes were ascertained from assessment and/or excision histology or follow-up. For each screen-reading strategy we calculated the number of detected and non-detected (including interval) cancers, cancer detection rates (CDRs), false positive recall (FPR) measures and incremental CDR relative to a comparator strategy. We estimated the false:true positive (FP:TP) ratio and sensitivity of each mammography screening strategy. Paired binary data were compared using McNemar's test. Amongst 7292 screening participants, there were 65 (including six interval) breast cancers; estimated first-year interval cancer rate was 0.82/1000 screens (95% confidence interval (CI): 0.30-1.79/1000). For single-reading, 35 cancers were detected at both 2D and 2D/3D-mammography, 20 cancers were detected only with 2D/3D-mammography compared with none at 2D-mammography alone (p<0.001) and 10 cancers were not detected. For double-reading, 39 cancers were detected at 2D-mammography and 2D/3D-mammography, 20 were detected only with 2D/3D-mammography compared with none detected at 2D-mammography alone (p<0.001) and six cancers were not detected. The incremental CDR attributable to 2D/3D-mammography (versus 2D-mammography) of 2.7/1000 screens (95% CI: 1.6-4.2) was evident for single and for double-reading. Incremental CDR attributable to double-reading (versus single-reading) of 0.55/1000 screens (95% CI: -0.02-1.4) was evident for 2D-mammography and for 2D/3D-mammography. Estimated FP:TP ratios showed that 2D/3D-mammography

  9. The effectiveness of using standardized patients to improve community physician skills in mammography counseling and clinical breast exam.

    PubMed

    Costanza, M E; Luckmann, R; Quirk, M E; Clemow, L; White, M J; Stoddard, A M

    1999-10-01

    Traditional didactic continuing education is relatively ineffective in improving physicians' clinical skills. We hypothesized that a centralized course including small group workshops utilizing standardized patients could improve clinical skills for a reasonable cost. We designed a 5-h course aimed at improving physicians' counseling skills (re: screening mammography) and clinical breast exam (CBE) skills. The course included lectures, demonstrations, and small group skills sessions utilizing standardized patients and was offered to 156 typical community-based primary care physicians. Pre- and postcourse evaluation included in-office assessments of physician CBE and counseling performance by standardized patients and a written test of knowledge and attitudes. A total of 54.5% of eligible physicians participated. They improved modestly in only one of three areas of counseling skills measured (providing counseling appropriate to the patient's readiness to accept mammography, P = 0.01). The overall CBE score increased substantially from 24.8 to 34.7 (P < 0.0001). Knowledge in all areas measured and confidence in counseling patients also increased. The basic course cost $202 per physician trained. Most community-based primary care physicians may find small group training and in-office evaluation involving standardized patients acceptable. Such training may be more effective in improving physical exam skills than complex communication skills.

  10. Fixed-facility workplace screening mammography.

    PubMed

    Reynolds, H E; Larkin, G N; Jackson, V P; Hawes, D R

    1997-02-01

    Potential barriers to compliance with screening mammography guidelines include the cost and inconvenience involved with undergoing the procedure. Workplace screening with mobile mammography is one possible approach to the convenience barrier. However, fixed-facility workplace screening is a viable alternative for any company with a large workforce in one location. This paper describes our initial experience with one such fixed facility. The facility was a cooperative venture by a large pharmaceutical company and an academic radiology department to provide convenient, no-cost (to the patient) screening mammography to employees, dependents, and retirees more than 40 years old. The pharmaceutical company built the facility within its corporate headquarters and the academic radiology department provided the equipment and personnel. The company was billed a fixed cost per examination. In the first 22 months of operation, 4210 (of 4559 scheduled) screening mammograms were obtained. The mean age of the population was 53 years old. Ninety percent of the screening mammograms were interpreted as negative or benign; 10% required additional workup. Of the screened population, 62 biopsies were recommended and 60 were performed. Of these, 42 were benign and 18 malignant. The cancer detection rate was 4.3 per 1000 (0.43%). At the time of diagnosis, six patients were stage 0, 10 patients were stage I, one patient was stage II, and one patient was stage III. Eleven of the 18 patients had minimal cancers. Of the patients who completed a satisfaction survey, 97% percent expressed a high degree of satisfaction with the screening process and stated they would use the facility in the future. A fixed facility for workplace screening mammography is a viable way to provide nearly barrier-free access to high-quality mammography. Patient acceptance is high.

  11. A screening mammography program. Staying alive and making it work.

    PubMed

    Monsees, B S; Destouet, J M

    1992-01-01

    The success of a mammography screening program requires thorough planning. A dependably high volume and a streamlined efficient operation are essential to survival of the program. Factors that warrant consideration prior to designing such a program include the following: Distinction between screening and diagnostic mammography examinations. Selection of a site that will meet the needs of the community and yet provide a consistently high volume. Low examination cost for screening mammography coupled with a detailed financial analysis and reappraisal on an ongoing basis. A customized marketing program that incorporates methods to increase awareness, compliance, and utilization by women and referring physicians. Well-trained, efficient, and dedicated personnel. An operation that is designed for rapid throughput and expeditious patient flow. An efficient plan for film handling, interpretation, reporting, and storage. Timely communication of examination results. A reliable mechanism for follow-up evaluation and outcome data collection. Establishment of a consistent and reliable quality assurance program and the production of high quality mammograms.

  12. Mammography: an update of the EUSOBI recommendations on information for women.

    PubMed

    Sardanelli, Francesco; Fallenberg, Eva M; Clauser, Paola; Trimboli, Rubina M; Camps-Herrero, Julia; Helbich, Thomas H; Forrai, Gabor

    2017-02-01

    This article summarises the information to be offered to women about mammography. After a delineation of the aim of early diagnosis of breast cancer, the difference between screening mammography and diagnostic mammography is explained. The need to bring images and reports from the previous mammogram (and from other recent breast imaging examinations) is highlighted. Mammography technique and procedure are described with particular attention to discomfort and pain experienced by a small number of women who undergo the test. Information is given on the recall during a screening programme and on the request for further work-up after a diagnostic mammography. The logic of the mammography report and of classification systems such as R1-R5 and BI-RADS is illustrated, and brief but clear information is given about the diagnostic performance of the test, with particular reference to interval cancers, i.e., those cancers that are missed at screening mammography. Moreover, the breast cancer risk due to radiation exposure from mammography is compared to the reduction in mortality obtained with the test, and the concept of overdiagnosis is presented with a reliable estimation of its extent. Information about new mammographic technologies (tomosynthesis and contrast-enhanced spectral mammography) is also given. Finally, frequently asked questions are answered. • Direct digital mammography should be preferred to film-screen or phosphor plates. • Screening (in asymptomatic women) should be distinguished from diagnosis (in symptomatic women). • A breast symptom has to be considered even after a negative mammogram. • Digital breast tomosynthesis increases cancer detection and decreases the recall rate. • Contrast-enhanced spectral mammography can help in cancer detection and lesion characterisation.

  13. The Assessment of the Likelihood of Mammography Usage with Relevant Factors among Women with Disabilities

    ERIC Educational Resources Information Center

    Kung, Pei-Tseng; Tsai, Wen-Chen; Chiou, Shang-Jyh

    2012-01-01

    Research that identifies the determinants of low mammography use among disabled people is scant. This study examines the determining factors related to the low usage of mammography among women with disabilities. To identify the barriers that prevent women with disabilities from participating in mammography screening can help authorities conceive…

  14. Cultural Views, Language Ability, and Mammography Use in Chinese American Women

    ERIC Educational Resources Information Center

    Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S.

    2009-01-01

    Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a…

  15. Differential Effects of Social Networks on Mammography Use by Poverty Status.

    PubMed

    Yeo, Younsook

    2016-01-01

    This study examines whether social networks have differential effects on mammography use depending on poverty status. Data were analyzed on US women (40+), employing logistic regression and simple slope analyses for a post hoc probing of moderating effects. Among women not in poverty, living with a spouse/partner and attending church, regardless of frequency, were positively associated with mammography use; family size was negatively associated. Among women living in poverty, mammography showed a positive association only with weekly church attendance. Mammography was negatively associated with health-related social interactions occurring through the Internet. Post hoc probing showed significant moderating effects of poverty on the relationship between online health-related interactions and mammography use. To make the Internet a meaningful health empowerment tool for women in poverty, future research should identify how health-related interactions that occur online affect women in poverty's psychological and behavioral reactions that will contribute to our understanding of why they are discouraged from having mammograms. The mechanisms behind the differential effects of church attendance and poverty status on mammography also need further clarification.

  16. Simulation of breast compression in mammography using finite element analysis: A preliminary study

    NASA Astrophysics Data System (ADS)

    Liu, Yan-Lin; Liu, Pei-Yuan; Huang, Mei-Lan; Hsu, Jui-Ting; Han, Ruo-Ping; Wu, Jay

    2017-11-01

    Adequate compression during mammography lowers the absorbed dose in the breast and improves the image quality. The compressed breast thickness (CBT) is affected by various factors, such as breast volume, glandularity, and compression force. In this study, we used the finite element analysis to simulate breast compression and deformation and validated the simulated CBT with clinical mammography results. Image data from ten subjects who had undergone mammography screening and breast magnetic resonance imaging (MRI) were collected, and their breast models were created according to the MR images. The non-linear tissue deformation under 10-16 daN in the cranial-caudal direction was simulated. When the clinical compression force was used, the simulated CBT ranged from 2.34 to 5.90 cm. The absolute difference between the simulated CBT and the clinically measured CBT ranged from 0.5 to 7.1 mm. The simulated CBT had a strong positive linear relationship to breast volume and a weak negative correlation to glandularity. The average simulated CBT under 10, 12, 14, and 16 daN was 5.68, 5.12, 4.67, and 4.25 cm, respectively. Through this study, the relationships between CBT, breast volume, glandularity, and compression force are provided for use in clinical mammography.

  17. Psychosocial Determinants of Mammography Follow-up after Receipt of Abnormal Mammography Results in Medically Underserved Women

    PubMed Central

    Fair, Alecia Malin; Wujcik, Debra; Lin, Jin-Mann Sally; Zheng, Wei; Egan, Kathleen M.; Grau, Ana M.; Champion, Victoria L.; Wallston, Kenneth A.

    2010-01-01

    This article targets the relationship between psychosocial determinants and abnormal screening mammography follow-up in a medically underserved population. Health belief scales were modified to refer to diagnostic follow-up versus annual screening. A retrospective cohort study design was used. Statistical analyses were performed examining relationships among sociodemographic factors, psychosocial determinants, and abnormal mammography follow-up. Women with lower mean internal health locus of control scores (3.14) were two times more likely than women with higher mean internal health locus of control scores (3.98) to have inadequate follow-up (OR = 2.53, 95% CI = 1.12–5.36). Women with less than a high school education had lower cancer fatalism scores than women who had completed high school (47.5 vs. 55.2, p-value = .02) and lower mean external health locus of control scores (3.0 vs. 5.3) (p-value<.01). These constructs have implications for understanding mammography follow-up among minority and medically underserved women. Further comprehensive study of these concepts is warranted. PMID:20173286

  18. Psychosocial determinants of mammography follow-up after receipt of abnormal mammography results in medically underserved women.

    PubMed

    Fair, Alecia Malin; Wujcik, Debra; Lin, Jin-Mann Sally; Zheng, Wei; Egan, Kathleen M; Grau, Ana M; Champion, Victoria L; Wallston, Kenneth A

    2010-02-01

    This article targets the relationship between psychosocial determinants and abnormal screening mammography follow-up in a medically underserved population. Health belief scales were modified to refer to diagnostic follow-up versus annual screening. A retrospective cohort study design was used. Statistical analyses were performed examining relationships among sociodemographic factors, psychosocial determinants, and abnormal mammography follow-up. Women with lower mean internal health locus of control scores (3.14) were two times more likely than women with higher mean internal health locus of control scores (3.98) to have inadequate follow-up (OR=2.53, 95% CI=1.12-5.36). Women with less than a high school education had lower cancer fatalism scores than women who had completed high school (47.5 vs. 55.2, p-value=.02) and lower mean external health locus of control scores (3.0 vs. 5.3) (p-value<.01). These constructs have implications for understanding mammography follow-up among minority and medically underserved women. Further comprehensive study of these concepts is warranted.

  19. Effectiveness of a Mobile Mammography Program.

    PubMed

    Stanley, Elizabeth; Lewis, Madelene C; Irshad, Abid; Ackerman, Susan; Collins, Heather; Pavic, Dag; Leddy, Rebecca J

    2017-12-01

    Mobile mammography units have increasingly been used to address patient health care disparities; however, there are limited data comparing mobile units to stationary sites. This study aims to evaluate the characteristics of women who underwent mammography screening in a mobile unit versus those who underwent mammography screening at a cancer center. In this retrospective study, we analyzed all screening mammography examinations performed in a mobile unit in 2014 (n = 1433 examinations). For comparison, we randomized and reviewed an equivalent number of screening mammography examinations performed at our cancer center in 2014 (n = 1434 examinations). BI-RADS assessment, adherence to follow-up, biopsies performed, cancer detection rate, and sociodemographic variables were recorded. An independent-samples t test was conducted to identify potential differences in age between cancer center patients and mobile unit patients. Chi-square analyses were used to test for associations between location and factors such as health insurance, race, marital status, geographic area, adherence to screening guidelines, recall rate, adherence to follow-up, and cancer detection rates. Patients visiting our cancer center (mean = 57.74 years; SD = 10.55) were significantly older than those visiting the mobile unit (mean = 52.58 years; SD = 8.19; p < 0.001). There was a significant association between location and health insurance status (χ 2 = 610.92; p < 0.001) with more uninsured patients undergoing screening in the mobile van (cancer center = 3.70%, mobile unit = 38.73%). There was a significant association between screening location and patient race (χ 2 = 118.75, p < 0.001), with more white patients being screened at the cancer center (cancer center = 47.28%, mobile unit = 33.30%), more black patients being screened in the mobile van (cancer center = 49.30%, mobile unit = 54.15%), and more Hispanic patients being screened in the mobile van (cancer center = 1.05%, mobile unit = 6

  20. Cost-effectiveness of digital mammography breast cancer screening.

    PubMed

    Tosteson, Anna N A; Stout, Natasha K; Fryback, Dennis G; Acharyya, Suddhasatta; Herman, Benjamin A; Hannah, Lucy G; Pisano, Etta D

    2008-01-01

    The DMIST (Digital Mammography Imaging Screening Trial) reported improved breast cancer detection with digital mammography compared with film mammography in selected population subgroups, but it did not assess the economic value of digital relative to film mammography screening. To evaluate the cost-effectiveness of digital mammography screening for breast cancer. Validated, discrete-event simulation model. Data from DMIST and publicly available U.S. data. U.S. women age 40 years or older. Lifetime. Societal and Medicare. All-film mammography screening; all-digital mammography screening; and targeted digital mammography screening, which is age-targeted digital mammography (for women <50 years of age) and age- and density-targeted digital mammography (for women <50 years of age or women > or =50 years of age with dense breasts). Cost per quality-adjusted life-year (QALY) gained. All-digital mammography screening cost $331,000 (95% CI, $268,000 to $403,000) per QALY gained relative to all-film mammography screening but was more costly and less effective than targeted digital mammography screening. Targeted digital mammography screening resulted in more screen-detected cases of cancer and fewer deaths from cancer than either all-film or all-digital mammography screening, with cost-effectiveness estimates ranging from $26,500 (CI, $21,000 to $33,000) per QALY gained for age-targeted digital mammography to $84,500 (CI, $75,000 to $93,000) per QALY gained for age- and density-targeted digital mammography. In the Medicare population, the cost-effectiveness of density-targeted digital mammography screening varied from a base-case estimate of $97,000 (CI, $77,000 to $131,000) to $257,000 per QALY gained (CI, $91,000 to $536,000) in the alternative-case analyses, in which the sensitivity of film mammography was increased and the sensitivity of digital mammography in women with nondense breasts was decreased. Results were sensitive to the cost of digital mammography and to

  1. Radiology workstation for mammography: preliminary observations, eyetracker studies, and design

    NASA Astrophysics Data System (ADS)

    Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.

    1991-07-01

    For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.

  2. Cultural views, language ability, and mammography use in Chinese American women.

    PubMed

    Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S

    2009-12-01

    Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a telephone interview. Regular mammography was defined as having two mammograms at age-appropriate recommended intervals. Cultural views were assessed by 30 items, and language ability measured women's ability in reading, writing, speaking, and listening to English. After controlling for risk perception, worry, physician recommendation, family encouragement, and access barriers, women holding a more Chinese/Eastern cultural view were significantly less likely to have had regular mammograms than those having a Western cultural view. English ability was positively associated with mammography adherence. The authors' results imply that culturally sensitive and language-appropriate educational interventions are likely to improve mammography adherence in this population.

  3. Cultural Views, Language Ability, and Mammography Use in Chinese American Women

    PubMed Central

    Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S.

    2013-01-01

    Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a telephone interview. Regular mammography was defined as having two mammograms at age-appropriate recommended intervals. Cultural views were assessed by 30 items, and language ability measured women’s ability in reading, writing, speaking, and listening to English. After controlling for risk perception, worry, physician recommendation, family encouragement, and access barriers, women holding a more Chinese/Eastern cultural view were significantly less likely to have had regular mammograms than those having a Western cultural view. English ability was positively associated with mammography adherence. The authors’ results imply that culturally sensitive and language-appropriate educational interventions are likely to improve mammography adherence in this population. PMID:19233947

  4. Travel by public transit to mammography facilities in 6 US urban areas.

    PubMed

    Graham, S; Lewis, B; Flanagan, B; Watson, M; Peipins, L

    2015-12-01

    We examined lack of private vehicle access and 30 minutes or longer public transportation travel time to mammography facilities for women 40 years of age or older in the urban areas of Boston, Philadelphia, San Antonio, San Diego, Denver, and Seattle to identify transit marginalized populations - women for whom these travel characteristics may jointly present a barrier to clinic access. This ecological study used sex and race/ethnicity data from the 2010 US Census and household vehicle availability data from the American Community Survey 2008-2012, all at Census tract level. Using the public transportation option on Google Trip Planner we obtained the travel time from the centroid of each census tract to all local mammography facilities to determine the nearest mammography facility in each urban area. Median travel times by public transportation to the nearest facility for women with no household access to a private vehicle were obtained by ranking travel time by population group across all U.S. census tracts in each urban area and across the entire study area. The overall median travel times for each urban area for women without household access to a private vehicle ranged from a low of 15 minutes in Boston and Philadelphia to 27 minutes in San Diego. The numbers and percentages of transit marginalized women were then calculated for all urban areas by population group. While black women were less likely to have private vehicle access, and both Hispanic and black women were more likely to be transit marginalized, this outcome varied by urban area. White women constituted the largest number of transit marginalized. Our results indicate that mammography facilities are favorably located for the large majority of women, although there are still substantial numbers for whom travel may likely present a barrier to mammography facility access.

  5. Travel by public transit to mammography facilities in 6 US urban areas

    PubMed Central

    Graham, S; Lewis, B; Flanagan, B; Watson, M; Peipins, L

    2017-01-01

    We examined lack of private vehicle access and 30 minutes or longer public transportation travel time to mammography facilities for women 40 years of age or older in the urban areas of Boston, Philadelphia, San Antonio, San Diego, Denver, and Seattle to identify transit marginalized populations - women for whom these travel characteristics may jointly present a barrier to clinic access. This ecological study used sex and race/ethnicity data from the 2010 US Census and household vehicle availability data from the American Community Survey 2008–2012, all at Census tract level. Using the public transportation option on Google Trip Planner we obtained the travel time from the centroid of each census tract to all local mammography facilities to determine the nearest mammography facility in each urban area. Median travel times by public transportation to the nearest facility for women with no household access to a private vehicle were obtained by ranking travel time by population group across all U.S. census tracts in each urban area and across the entire study area. The overall median travel times for each urban area for women without household access to a private vehicle ranged from a low of 15 minutes in Boston and Philadelphia to 27 minutes in San Diego. The numbers and percentages of transit marginalized women were then calculated for all urban areas by population group. While black women were less likely to have private vehicle access, and both Hispanic and black women were more likely to be transit marginalized, this outcome varied by urban area. White women constituted the largest number of transit marginalized. Our results indicate that mammography facilities are favorably located for the large majority of women, although there are still substantial numbers for whom travel may likely present a barrier to mammography facility access. PMID:29285434

  6. Effectiveness of Computer-Aided Detection in Community Mammography Practice

    PubMed Central

    Abraham, Linn; Taplin, Stephen H.; Geller, Berta M.; Carney, Patricia A.; D’Orsi, Carl; Elmore, Joann G.; Barlow, William E.

    2011-01-01

    Background Computer-aided detection (CAD) is applied during screening mammography for millions of US women annually, although it is uncertain whether CAD improves breast cancer detection when used by community radiologists. Methods We investigated the association between CAD use during film-screen screening mammography and specificity, sensitivity, positive predictive value, cancer detection rates, and prognostic characteristics of breast cancers (stage, size, and node involvement). Records from 684 956 women who received more than 1.6 million film-screen mammograms at Breast Cancer Surveillance Consortium facilities in seven states in the United States from 1998 to 2006 were analyzed. We used random-effects logistic regression to estimate associations between CAD and specificity (true-negative examinations among women without breast cancer), sensitivity (true-positive examinations among women with breast cancer diagnosed within 1 year of mammography), and positive predictive value (breast cancer diagnosed after positive mammograms) while adjusting for mammography registry, patient age, time since previous mammography, breast density, use of hormone replacement therapy, and year of examination (1998–2002 vs 2003–2006). All statistical tests were two-sided. Results Of 90 total facilities, 25 (27.8%) adopted CAD and used it for an average of 27.5 study months. In adjusted analyses, CAD use was associated with statistically significantly lower specificity (OR = 0.87, 95% confidence interval [CI] = 0.85 to 0.89, P < .001) and positive predictive value (OR = 0.89, 95% CI = 0.80 to 0.99, P = .03). A non-statistically significant increase in overall sensitivity with CAD (OR = 1.06, 95% CI = 0.84 to 1.33, P = .62) was attributed to increased sensitivity for ductal carcinoma in situ (OR = 1.55, 95% CI = 0.83 to 2.91; P = .17), although sensitivity for invasive cancer was similar with or without CAD (OR = 0.96, 95% CI = 0.75 to 1.24; P = .77). CAD was not associated with

  7. Ultrasound as an Adjunct to Mammography for Breast Cancer Screening: A Health Technology Assessment

    PubMed Central

    Nikitovic-Jokic, Milica; Tu, Hong Anh; Palimaka, Stefan; Higgins, Caroline; Holubowich, Corinne

    2016-01-01

    Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Ultrasound has been suggested as a safe adjunct screening tool that can detect breast cancers missed on mammography. We investigated the benefits, harms, cost-effectiveness, and cost burden of ultrasound as an adjunct to mammography compared with mammography alone for screening women at average risk and at high risk for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, EBM Reviews, and the NHS Economic Evaluation Database, from January 1998 to June 2015, for evidence of effectiveness, harms, diagnostic accuracy, and cost-effectiveness. Only studies evaluating the use of ultrasound as an adjunct to mammography in the specified populations were included. We also conducted a cost analysis to estimate the costs in Ontario over the next 5 years to fund ultrasound as an adjunct to mammography in breast cancer screening for high-risk women who are contraindicated for MRI, the current standard of care to supplement mammography. Results No studies in average-risk women met the inclusion criteria of the clinical review. We included 5 prospective, paired cohort studies in high-risk women, 4 of which were relevant to the Ontario context. Adjunct ultrasound identified between 2.3 and 5.9 additional breast cancers per 1,000 screens. The average pooled sensitivity of mammography and ultrasound was 53%, a statistically significant increase relative to mammography alone (absolute increase 13%; P < .05). The average pooled specificity of the combined test was 96%, an absolute increase in the false-positive rate of 2% relative to mammography screening alone. The GRADE for this body of evidence was low. Additional annual costs of using breast ultrasound as an adjunct to mammography for high-risk women in Ontario contraindicated for MRI would range from $15,500 to $30,250 in the next 5 years

  8. Healthcare access and mammography screening in Michigan: a multilevel cross-sectional study

    PubMed Central

    2012-01-01

    Background Breast cancer screening rates have increased over time in the United States. However actual screening rates appear to be lower among black women compared with white women. Purpose To assess determinants of breast cancer screening among women in Michigan USA, focusing on individual and neighborhood socio-economic status and healthcare access. Methods Data from 1163 women ages 50-74 years who participated in the 2008 Michigan Special Cancer Behavioral Risk Factor Survey were analyzed. County-level SES and healthcare access were obtained from the Area Resource File. Multilevel logistic regression models were fit using SAS Proc Glimmix to account for clustering of individual observations by county. Separate models were fit for each of the two outcomes of interest; mammography screening and clinical breast examination. For each outcome, two sequential models were fit; a model including individual level covariates and a model including county level covariates. Results After adjusting for misclassification bias, overall cancer screening rates were lower than reported by survey respondents; black women had lower mammography screening rates but higher clinical breast examination rates than white women. However, after adjusting for other individual level variables, race was not a significant predictor of screening. Having health insurance or a usual healthcare provider were the most important predictors of cancer screening. Discussion Access to healthcare is important to ensuring appropriate cancer screening among women in Michigan. PMID:22436125

  9. A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.

    PubMed

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius

    2017-06-01

    The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.

  10. Mammographic density is the main correlate of tumors detected on ultrasound but not on mammography.

    PubMed

    Häberle, Lothar; Fasching, Peter A; Brehm, Barbara; Heusinger, Katharina; Jud, Sebastian M; Loehberg, Christian R; Hack, Carolin C; Preuss, Caroline; Lux, Michael P; Hartmann, Arndt; Vachon, Celine M; Meier-Meitinger, Martina; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger

    2016-11-01

    Although mammography screening programs do not include ultrasound examinations, some diagnostic units do provide women with both mammography and ultrasonography. This article is concerned with estimating the risk of a breast cancer patient diagnosed in a hospital-based mammography unit having a tumor that is visible on ultrasound but not on mammography. A total of 1,399 women with invasive breast cancer from a hospital-based diagnostic mammography unit were included in this retrospective study. For inclusion, mammograms from the time of the primary diagnosis had to be available for computer-assisted assessment of percentage mammographic density (PMD), as well as Breast Imaging Reporting and Data System (BIRADS) assessment of mammography. In addition, ultrasound findings were available for the complete cohort as part of routine diagnostic procedures, regardless of any patient or imaging characteristics. Logistic regression analyses were conducted to identify predictors of mammography failure, defined as BIRADS assessment 1 or 2. The probability that the visibility of a tumor might be masked at diagnosis was estimated using a regression model with the identified predictors. Tumors were only visible on ultrasound in 107 cases (7.6%). PMD was the strongest predictor for mammography failure, but age, body mass index and previous breast surgery also influenced the risk, independently of the PMD. Risk probabilities ranged from 1% for a defined low-risk group up to 40% for a high-risk group. These findings might help identify women who should be offered ultrasound examinations in addition to mammography. © 2016 UICC.

  11. Influence of Demographic Factors, Knowledge, and Beliefs on Jordanian Women’s Intention to Undergo Mammography Screening

    PubMed Central

    Othman, Areej K.; Kiviniemi, Marc T.; Wu, Yow-Wu B.; Lally, Robin M.

    2013-01-01

    Purpose The purpose of this study was to determine the influence of demographic characteristics, breast cancer knowledge, fatalistic beliefs, health beliefs, and subjective norms on Jordanian women’s intention to participate in mammography screening. Design A cross-sectional survey was used to collect data at 14 comprehensive healthcare centers in Amman and Zarqa, Jordan. A convenience sample of 142 Jordanian women 40 years of age or older with no history of breast cancer and able to read and write in Arabic participated. Methods Self-report surveys included a combination of researcher-designed and existing instruments to measure the study variables. Data were analyzed using descriptive statistics, Pearson’s correlation, t tests, and multiple logistic regression. Findings Jordanian women surveyed lacked knowledge about breast cancer. Social norms and self-efficacy highly influenced these women’s intention to engage in mammography screening. Younger women were more willing to indicate intention to engage in mammographic screening. Conclusions Self-efficacy and the social connectedness of Jordanian society, but not religious beliefs or perceived barriers to screening, influence Jordanian women’s intention to undergo mammography. Future research should examine cultural influences, rather than religious beliefs, and investigate Jordanian women’s potentially unique perspectives on barriers to actual mammography screening behavior. Clinical Relevance The prevalence of mammography screening may be enhanced by focusing interventions on Jordanian women’s support systems and empowering women by providing knowledge and skills needed to engage in the procedure. PMID:22339890

  12. Evaluation of the Utility of Screening Mammography for High-Risk Women Undergoing Screening Breast MR Imaging.

    PubMed

    Lo, Glen; Scaranelo, Anabel M; Aboras, Hana; Ghai, Sandeep; Kulkarni, Supriya; Fleming, Rachel; Bukhanov, Karina; Crystal, Pavel

    2017-10-01

    Purpose To evaluate the value of mammography in detecting breast cancer in high-risk women undergoing screening breast magnetic resonance (MR) imaging. Materials and Methods An ethics-approved, retrospective review of prospective databases was performed to identify outcomes of 3934 screening studies (1977 screening MR imaging examinations and 1957 screening mammograms) performed between January 2012 and July 2014 in 1249 high-risk women. Performance measures including recall and cancer detection rates, sensitivity, specificity, and positive predictive values were calculated for both mammography and MR imaging. Results A total of 45 cancers (33 invasive and 12 ductal carcinomas in situ) were diagnosed, 43 were seen with MR imaging and 14 with both mammography and MR imaging. Additional tests (further imaging and/or biopsy) were recommended in 461 screening MR imaging studies (recall rate, 23.3%; 95% confidence interval [CI]: 21.5%, 25.2%), and mammography recalled 217 (recall rate, 11.1%; 95% CI: 9.7%, 12.6%). The cancer detection rate for MR imaging was 21.8 cancers per 1000 examinations (95% CI: 15.78, 29.19) and that for mammography was 7.2 cancers per 1000 examinations (95% CI: 3.92, 11.97; P < .001). Sensitivity and specificity of MR imaging were 96% and 78% respectively, and those of mammography were 31% and 89%, respectively (P < .001). Positive predictive value for MR imaging recalls was 9.3% (95% CI: 6.83%, 12.36%) and that for mammography recalls was 6.5% (95% CI: 3.57%, 10.59%). Conclusion Contemporaneous screening mammography did not have added value in detection of breast cancer for women who undergo screening MR imaging. Routine use of screening mammography in women undergoing screening breast MR imaging warrants reconsideration. © RSNA, 2017 Online supplemental material is available for this article.

  13. Comparative Effectiveness of Digital Versus Film-Screen Mammography in Community Practice in the United States

    PubMed Central

    Kerlikowske, Karla; Hubbard, Rebecca A.; Miglioretti, Diana L.; Geller, Berta M.; Yankaskas, Bonnie C.; Lehman, Constance D.; Taplin, Stephen H.; Sickles, Edward A.

    2013-01-01

    Background Few studies have examined the comparative effectiveness of digital versus film-screen mammography in U.S. community practice. Objective To determine whether the interpretive performance of digital and film-screen mammography differs. Design Prospective cohort study. Setting Mammography facilities in the Breast Cancer Surveillance Consortium. Participants 329 261 women aged 40 to 79 years underwent 869 286 mammograms (231 034 digital; 638 252 film-screen). Measurements Invasive cancer or ductal carcinoma in situ diagnosed within 12 months of a digital or film-screen examination and calculation of mammography sensitivity, specificity, cancer detection rates, and tumor outcomes. Results Overall, cancer detection rates and tumor characteristics were similar for digital and film-screen mammography, but the sensitivity and specificity of each modality varied by age, tumor characteristics, breast density, and menopausal status. Compared with film-screen mammography, the sensitivity of digital mammography was significantly higher for women aged 60 to 69 years (89.9% vs. 83.0%; P = 0.014) and those with estrogen receptor-negative cancer (78.5% vs. 65.8%; P = 0.016); borderline significantly higher for women aged 40 to 49 years (82.4% vs. 75.6%; P = 0.071), those with extremely dense breasts (83.6% vs. 68.1%; P= 0.051), and pre- or perimenopausal women (87.1% vs. 81.7%; P = 0.057); and borderline significantly lower for women aged 50 to 59 years (80.5% vs. 85.1%; P = 0.097). The specificity of digital and film-screen mammography was similar by decade of age, except for women aged 40 to 49 years (88.0% vs. 89.7%; P< 0.001). Limitation Statistical power for subgroup analyses was limited. Conclusion Overall, cancer detection with digital or film-screen mammography is similar in U.S. women aged 50 to 79 years undergoing screening mammography. Women aged 40 to 49 years are more likely to have extremely dense breasts and estrogen receptor-negative tumors; if they are

  14. Mammography in asymptomatic women aged 40-49 years

    PubMed Central

    Silva, Flávio Xavier; Katz, Leila; Souza, Alex Sandro Rolland; Amorim, Melania Maria Ramos

    2014-01-01

    OBJECTIVE To assess findings of mammography of and interventions resulting from breast cancer screening in women aged 40-49 years with no increased risk (typical risk) of breast cancer. METHODS This cross-sectional study evaluated women aged 40-49 years who underwent mammography screening in a mastology reference center in Recife, PE, Northeastern Brazil, between January 2010 and October 2011. Women with breast-related complaints, positive findings in the physical examination, or high risk of breast cancer were excluded. RESULTS The 1,000 mammograms performed were classified into the following Breast Imaging-Reporting and Data System (BI-RADS) categories BI-RADS 0, 232; BI-RADS 1, 294; BI-RADS 2, 294; BI-RADS 3, 16; BI-RADS 4A, 2; BI-RADS 5, 1. There was one case of grade II invasive ductal carcinoma and various interventions, including 469 ultrasound scans, 53 referrals to mastologists, 11 cytological examinations, and 8 biopsies. CONCLUSIONS Mammography screening in women aged 40-49 years with typical risk of breast cancer led to the performance of other interventions. However, it also resulted in increased costs without demonstrable efficacy in decreasing mortality. PMID:26039396

  15. Mammography film processor replenishment rate: bromide level monitoring.

    PubMed

    Kimme-Smith, C; Wuelfing, P; Kitts, E L; Cagnon, C; Basic, M; Bassett, L

    1997-03-01

    The effects of the mammography film processing replenishment rate on contrast and speed are studied sensitometrically. Two experiments studied decreasing replenishment rates in the Kodak RP developer and quantified changes in the developer by measuring bromide ion concentrations. First, values of NaBr concentration from 1.7 to 8.4 g/L, achieved by reducing the replenishment rate, were tested with sensitometry strips. Second, the developer replenishment rate of a high volume dedicated mammography processor was reduced by one-third, to 20 cm3/1560 cm2, so that the NaBr concentration rose from 2.0 to 12.36. Sensitometric results for four film types and patient films were tested for changes from standard values as NaBr concentration was restored to 3.31 g/L. Fifty-five clinical images obtained at 7.3-9.3 NaBr g/L were compared to their matching previous films, with NaBr levels of 2-3 g/L, for contrast and visibility of the skin line. For the range of the NaBr ion from 1.7 to 7 g/L, no significant sensitometric differences were found. Above 7 g/L, different film types had different sensitometric results. From 7.3 to 9.3 NaBr g/L, 47.5% of the clinical films reviewed by four radiologists had less contrast compared to previous films. Dedicated mammography processors with high film volume (i.e., those that do not have excessive oxidation or foreign dye problems) can operate at lower replenishment rates than are currently employed. All common mammography film types are stable at these lower replenishment rates up to 7.0 NaBr g/L.

  16. The radiation metrology network related to the field of mammography: implementation and uncertainty analysis of the calibration system

    NASA Astrophysics Data System (ADS)

    Peixoto, J. G. P.; de Almeida, C. E.

    2001-09-01

    It is recognized by the international guidelines that it is necessary to offer calibration services for mammography beams in order to improve the quality of clinical diagnosis. Major efforts have been made by several laboratories in order to establish an appropriate and traceable calibration infrastructure and to provide the basis for a quality control programme in mammography. The contribution of the radiation metrology network to the users of mammography is reviewed in this work. Also steps required for the implementation of a mammography calibration system using a constant potential x-ray and a clinical mammography x-ray machine are presented. The various qualities of mammography radiation discussed in this work are in accordance with the IEC 61674 and the AAPM recommendations. They are at present available at several primary standard dosimetry laboratories (PSDLs), namely the PTB, NIST and BEV and a few secondary standard dosimetry laboratories (SSDLs) such as at the University of Wisconsin and at the IAEA's SSDL. We discuss the uncertainties involved in all steps of the calibration chain in accord with the ISO recommendations.

  17. Promoting mammography screening among Chinese American women using a message-framing intervention.

    PubMed

    Sun, Yiyuan; Sarma, Elizabeth A; Moyer, Anne; Messina, Catherine R

    2015-07-01

    This study examined the role of women's perceptions about the relative pros versus cons (decisional balance) of mammography in moderating Chinese American women's responses to gain- and loss-framed messages that promote mammography. One hundred and forty-three Chinese American women who were currently nonadherent to guidelines for receiving annual screening mammograms were randomly assigned to read either a gain- or loss-framed culturally appropriate print brochure about mammography screening. Mammography screening was self-reported at a 2-month follow-up. Although there was not a main effect for message frame, the hypothesized interaction between message frame and decisional balance was significant, indicating that women who received a framed message that matched their decisional balance were significantly more likely to have obtained a mammogram by the follow-up than women who received a mismatched message. Results suggest that decisional balance, and more generally, perceptions about mammography, may be an important moderator of framing effects for mammography among Chinese American women. The match between message frame and decisional balance should be considered when attempting to encourage Chinese American women to receive mammography screening, as a match between the two may be most persuasive. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. [Hierarchy structuring for mammography technique by interpretive structural modeling method].

    PubMed

    Kudo, Nozomi; Kurowarabi, Kunio; Terashita, Takayoshi; Nishimoto, Naoki; Ogasawara, Katsuhiko

    2009-10-20

    Participation in screening mammography is currently desired in Japan because of the increase in breast cancer morbidity. However, the pain and discomfort of mammography is recognized as a significant deterrent for women considering this examination. Thus quick procedures, sufficient experience, and advanced skills are required for radiologic technologists. The aim of this study was to make the point of imaging techniques explicit and to help understand the complicated procedure. We interviewed 3 technologists who were highly skilled in mammography, and 14 factors were retrieved by using brainstorming and the KJ method. We then applied Interpretive Structural Modeling (ISM) to the factors and developed a hierarchical concept structure. The result showed a six-layer hierarchy whose top node was explanation of the entire procedure on mammography. Male technologists were related to as a negative factor. Factors concerned with explanation were at the upper node. We gave attention to X-ray techniques and considerations. The findings will help beginners improve their skills.

  19. The relationship of social support concept and repeat mammography among Iranian women.

    PubMed

    Farhadifar, Fariba; Taymoori, Parvaneh; Bahrami, Mitra; Zarea, Shamsy

    2015-10-24

    Breast cancer ranks as the first most common cancer among the Iranian women. The regular repeat of mammography with 1-2 year intervals leads to the increased efficiency of early detection of breast cancer. The present study examined the predictors of repeat mammography. It was hypothesized that higher social support is connected with mammography repeat. A cross-sectional study was carried out among 400 women 50 years and older in Sanandaj, Iran. Data was collected by the questionnaire including information on socio demographical variables and measuring social support level. Data was analyzed by SPSS16 software. Multiple logistic regression was used to determine the predictive power of demographic variables and dimensions of social support for repeat mammography. Women aged 50-55 years had three times odds of repeat mammography compared to women aged 56-60 years) OR, 3.02). Married women had greater odds of repeat mammography compared to single women (P < 0.006). The probability of repeat mammography in women with higher social support was 0.93 times greater than the women with lower social support (OR, 0.93; 95 % CI, 0.91-0.95; P < 0.0001). Iranian women are less likely repeat mammography than other Asian women. Identifying the associations between perceived social support and repeat mammography may offer detailed information to allow for future study and guide the development of interventions not only for Iranian women but also for similar cultural that received pay too little attention to date in the breast cancer literature.

  20. Mammography facilities are accessible, so why is utilization so low?

    PubMed

    Mobley, Lee R; Kuo, Tzy-Mey May; Clayton, Laurel J; Evans, W Douglas

    2009-08-01

    This study examines new socio-ecological variables reflecting community context as predictors of mammography use. The conceptual model is a hybrid of traditional health-behavioral and socio-ecological constructs with an emphasis on spatial interaction among women and their environments, differentiating between several levels of influence for community context. Multilevel probability models of mammography use are estimated. The study sample includes 70,129 women with traditional Medicare fee-for-service coverage for inpatient and outpatient services, drawn from the SEER-Medicare linked data. The study population lives in heterogeneous California, where mammography facilities are dense but utilization rates are low. Several contextual effects have large significant impacts on the probability of mammography use. Women living in areas with higher proportions of elderly in poverty are 33% less likely to use mammography. However, dually eligible women living in these poor areas are 2% more likely to use mammography than those without extra assistance living in these areas. Living in areas with higher commuter intensity, higher violent crime rates, greater land use mix (urbanicity), or more segregated Hispanic communities exhibit -14%, -1%, -6%, and -3% (lower) probability of use, respectively. Women living in segregated American Indian communities or in communities where more elderly women live alone exhibit 16% and 12% (higher) probability of use, respectively. Minority women living in more segregated communities by their minority are more likely to use mammography, suggesting social support, but this is significant for Native Americans only. Women with disability as their original reason for entitlement are found 40% more likely to use mammography when they reside in communities with high commuter intensity, suggesting greater ease of transportation for them in these environments. Socio-ecological variables reflecting community context are important predictors of

  1. The mammography screening employee inreach program.

    PubMed

    Robinson, Joanne; Seltzer, Vicki; Lawrence, Loretta; Autz, George; Kostroff, Karen; Weiselberg, Lora; Colagiacomo, Maria

    2007-02-01

    To determine whether our health care employees were undergoing mammography screening according to American Cancer Society guidelines and to determine whether aggressive outreach, education and streamlining of mammography scheduling could improve compliance. All female employees at North Shore University Hospital (NSUH) and several other health system facilities (SF) were sent mailings to their homes that included breast health education and mammography screening guidelines, a questionnaire regarding their own mammography screening history and the opportunity to have their mammography screening scheduled by the Mammography Screening Employee Inreach Program (MSEIP) coordinator. Of the approximately 2,700 female employees aged 40 and over at NSUH and SF, 2,235 (82.7%) responded to the questionnaire, and 1,455 had a mammogram done via the MSEIP. Of the 1,455, 43% either were overdue for a mammogram or had never had one. During a second year of the MSEIP at NSUH and SF, an additional 1,706 mammograms were done. People employed in health care jobs do not necessarily avail themselves of appropriate health care screening. An aggressive program that utilized education, outreach and assistance with scheduling was effective in increasing compliance with mammography screening.

  2. Contrast Enhanced Spectral Mammography: A Review.

    PubMed

    Patel, Bhavika K; Lobbes, M B I; Lewin, John

    2018-02-01

    Contrast-enhanced spectral mammography (CESM) provides low-energy 2D mammographic images comparable to standard digital mammography and a post-contrast recombined image to assess tumor neovascularity similar to magnetic resonance imaging (MRI). The utilization of CESM in the United States is currently low but could increase rapidly given many potential indications for clinical use. This article discusses historical background and literature review of indications and diagnostic accuracy of CESM to date. CESM is a growing technique for breast cancer detection and diagnosis that has levels of sensitivity and specificity on par with contrast-enhanced breast MRI. Because of its similar performance and ease of implementation, CESM is being adopted for multiple indications previously reserved for MRI, such as problem-solving, disease extent in newly diagnosed patients, and evaluating the treatment response of neoadjuvant chemotherapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading--Oslo I study.

    PubMed

    Skaane, Per; Young, Kari; Skjennald, Arnulf

    2003-12-01

    To compare screen-film and full-field digital mammography with soft-copy reading in a population-based screening program. Full-field digital and screen-film mammography were performed in 3,683 women aged 50-69 years. Two standard views of each breast were acquired with each modality. Images underwent independent double reading with use of a five-point rating scale for probability of cancer. Recall rates and positive predictive values were calculated. Cancer detection rates determined with both modalities were compared by using the McNemar test for paired proportions. Retrospective side-by-side analysis for conspicuity of cancers was performed by an external independent radiologist group with experience in both modalities. In 3,683 cases, 31 cancers were detected. Screen-film mammography depicted 28 (0.76%) malignancies, and full-field digital mammography depicted 23 (0.62%) malignancies. The difference between cancer detection rates was not significant (P =.23). The recall rate for full-field digital mammography (4.6%; 168 of 3,683 cases) was slightly higher than that for screen-film mammography (3.5%; 128 of 3,683 cases). The positive predictive value based on needle biopsy results was 46% for screen-film mammography and 39% for full-field digital mammography. Side-by-side image comparison for cancer conspicuity led to classification of 19 cancers as equal for probability of malignancy, six cancers as slightly better demonstrated at screen-film mammography, and six cancers as slightly better demonstrated at full-field digital mammography. There was no statistically significant difference in cancer detection rate between screen-film and full-field digital mammography. Cancer conspicuity was equal with both modalities. Full-field digital mammography with soft-copy reading is comparable to screen-film mammography in population-based screening.

  4. Mammography Decision Aid Reduces Decisional Conflict for Women in Their Forties Considering Screening.

    PubMed

    Eden, Karen B; Scariati, Paula; Klein, Krystal; Watson, Lindsey; Remiker, Mark; Hribar, Michelle; Forro, Vanessa; Michaels, LeAnn; Nelson, Heidi D

    2015-12-01

    Clinical guidelines recommend a personalized approach to mammography screening for women in their forties; however, methods to do so are lacking. An evidence-based mammography screening decision aid was developed as an electronic mobile application and evaluated in a before-after study. The decision aid (Mammopad) included modules on breast cancer, mammography, risk assessment, and priority setting about screening. Women aged 40-49 years who were patients of rural primary care clinics, had no major risk factors for breast cancer, and no mammography during the previous year were invited to use the decision aid. Twenty women participated in pretesting of the decision aid and 75 additional women completed the before-after study. The primary outcome was decisional conflict measured before and after using Mammopad. Secondary outcomes included decision self-efficacy and intention to begin or continue mammography screening. Differences comparing measures before versus after use were determined using Wilcoxon signed rank tests. After using Mammopad, women reported reduced decisional conflict based on mean Decisional Conflict Scale scores overall (46.33 versus 8.33; Z = -7.225; p < 0.001) and on all subscales (p < 0.001). Women also reported increased mean Decision Self-Efficacy Scale scores (79.67 versus 95.73; Z = 6.816, p < 0.001). Although 19% of women changed their screening intentions, this was not statistically significant. Women reported less conflict about their decisions for mammography screening, and felt more confident to make decisions after using Mammopad. This approach may help guide women through the decision making process to determine personalized screening choices that are appropriate for them.

  5. Artificial neural networks in mammography interpretation and diagnostic decision making.

    PubMed

    Ayer, Turgay; Chen, Qiushi; Burnside, Elizabeth S

    2013-01-01

    Screening mammography is the most effective means for early detection of breast cancer. Although general rules for discriminating malignant and benign lesions exist, radiologists are unable to perfectly detect and classify all lesions as malignant and benign, for many reasons which include, but are not limited to, overlap of features that distinguish malignancy, difficulty in estimating disease risk, and variability in recommended management. When predictive variables are numerous and interact, ad hoc decision making strategies based on experience and memory may lead to systematic errors and variability in practice. The integration of computer models to help radiologists increase the accuracy of mammography examinations in diagnostic decision making has gained increasing attention in the last two decades. In this study, we provide an overview of one of the most commonly used models, artificial neural networks (ANNs), in mammography interpretation and diagnostic decision making and discuss important features in mammography interpretation. We conclude by discussing several common limitations of existing research on ANN-based detection and diagnostic models and provide possible future research directions.

  6. REPEAT MAMMOGRAPHY SCREENING AMONG UNMARRIED WOMEN WITH AND WITHOUT A DISABILITY

    PubMed Central

    Clark, Melissa A.; Rogers, Michelle L.; Wen, Xiaozhong; Wilcox, Victoria; McCarthy-Barnett, Kate; Panarace, Jeanne; Manning, Carol; Allen, Susan; Rakowski, William

    2009-01-01

    Objectives Unmarried women with disabilities may be a particularly vulnerable group for underutilization of repeat mammography screening. Our goal was to compare the breast cancer screening experiences of unmarried women with disabilities (WWD) versus women with no disabilities (WND), and determine whether these experiences are associated with adherence to repeat screening. Methods We conducted a matched cohort study of 93 WWD and 93 WND to compare mammography experiences by disability status, examine rates of repeat mammography by disability status, and identify factors that are associated with repeat mammography. Results WWD were less likely to be on-schedule than WND in univariable (54.8% vs. 71.0%; relative risk = 0.77, 95% CL = 0.61, 0.97), but not multivariable, analyses. In multivariable analyses, there was a significant interaction between disability status and positive experiences as the reasons for returning to the same mammography facility. Among WND, repeat screening ranged from 59% to 86%, depending on the number of positive experiences endorsed (range=1–5). In contrast, among WWD, screening rates were only 37% among those who did not report any positive experiences and increased to a maximum of 60% regardless of whether women endorsed one to four or all five positive experiences. Severity and type of disability were not associated with repeat screening. Conclusions WWD may be less likely than WND to remain on-schedule for mammography. WWD who do not report any positive experiences as reasons for returning to a mammography facility may be at particularly high risk of underutilization of screening. PMID:19775912

  7. Health Insurance Mandates, Mammography, and Breast Cancer Diagnoses

    PubMed Central

    Bitler, Marianne P.

    2016-01-01

    We examine the effects of state health insurance mandates requiring coverage of screening mammograms. We find evidence that mammography mandates significantly increased mammography screenings by 4.5–25 percent. Effects are larger for women with less than a high school degree in states that ban deductibles, a policy similar to a provision of federal health reform that eliminates cost-sharing for preventive care. We also find that mandates increased detection of early stage in-situ pre-cancers. Finally, we find a substantial proportion of the increased screenings were attributable to mandates that are not consistent with current recommendations of the American Cancer Society. PMID:29527253

  8. Informed decision making before initiating screening mammography: does it occur and does it make a difference?

    PubMed

    Nekhlyudov, Larissa; Li, Rong; Fletcher, Suzanne W

    2008-12-01

    Informed decision making regarding screening mammography is recommended for women under age 50. To what extent it occurs in clinical settings is unclear. Using a mailed instrument, we surveyed women aged 40-44 prior to their first screening mammogram. All women were members of a large health maintenance organization and received care at a large medical practice in the Greater Boston area. The survey measured informed decision making, decisional conflict, satisfaction, and screening mammography knowledge and intentions to undergo screening. Ninety-six women responded to the survey (response rate 47%). Overall, women reported limited informed decision making regarding screening mammography, both with respect to information exchange and involvement in the decision process. Less than half (47%) reported discussing the benefits of screening; 23% the uncertainties; and only 7% the harms. About 30% reported discussing the nature of the decision or clinical issue; and 29% reported their provider elicited their preferred role in the decision; 38% their preferences; and 24% their understanding of the information. Women who were uninformed had higher decisional conflict (2.37 vs. 1.83, P=0.005) about screening mammography and were more likely to be dissatisfied with the information and involvement. Women's screening mammography knowledge was limited in most areas; however being presented with information did not diminish their intentions to undergo screening. Informed decision making before initiating screening mammography is limited in this setting. There appears to be little indication that information about the benefits and harms decreases women's intentions to undergo screening. Methods to communicate information to women before initiating screening mammography are needed.

  9. ACR BI-RADS Assessment Category 4 Subdivisions in Diagnostic Mammography: Utilization and Outcomes in the National Mammography Database.

    PubMed

    Elezaby, Mai; Li, Geng; Bhargavan-Chatfield, Mythreyi; Burnside, Elizabeth S; DeMartini, Wendy B

    2018-05-01

    Purpose To determine the utilization and positive predictive value (PPV) of the American College of Radiology (ACR) Breast Imaging Data and Reporting System (BI-RADS) category 4 subdivisions in diagnostic mammography in the National Mammography Database (NMD). Materials and Methods This study involved retrospective review of diagnostic mammography data submitted to the NMD from January 1, 2008 to December 30, 2014. Utilization rates of BI-RADS category 4 subdivisions were compared by year, facility (type, location, census region), and examination (indication, finding type) characteristics. PPV3 (positive predictive value for biopsies performed) was calculated overall and according to category 4 subdivision. The χ 2 test was used to test for significant associations. Results Of 1 309 950 diagnostic mammograms, 125 447 (9.6%) were category 4, of which 33.3% (41 841 of 125 447) were subdivided. Subdivision utilization rates were higher (P < .001) in practices that were community, suburban, or in the West; for examination indication of prior history of breast cancer; and for the imaging finding of architectural distortion. Of 41 841 category 4 subdivided examinations, 4A constituted 55.6% (23 258 of 41 841) of the examinations; 4B, 31.8% (13 302 of 41 841) of the examinations; and 4C, 12.6% (5281 of 41 841) of the examinations. Pathologic outcomes were available in 91 563 examinations, and overall category 4 PPV3 was 21.1% (19 285 of 91 563). There was a statistically significant difference in PPV3 according to category 4 subdivision (P < .001): The PPV of 4A was 7.6% (1274 of 16 784), that of 4B was 22% (2317 of 10 408), and that of 4C was 69.3% (2839 of 4099). Conclusion Although BI-RADS suggests their use, subdivisions were utilized in the minority (33.3% [41 841 of 125 447]) of category 4 diagnostic mammograms, with variability based on facility and examination characteristics. When subdivisions were used, PPV3s were in BI-RADS-specified malignancy ranges. This

  10. The influence of social support relationships on mammography screening in African-American women.

    PubMed

    Fowler, Barbara Ann

    2007-07-01

    Evidence indicates that mammography screenings have increased in African-American women who are 50 years of age or older; however, they continue to experience later-stage discovery and poorer survival rates from breast cancer compared to White women. Although research has consistently found that social support relationships affects mammography screening in African-American women, little is known about the preventive health behaviors of individuals in these relationships that may be associated with mammography screening. This study examined that association and found that social support relationships, defined as blood-relatives and extended kinship networks, stressed personal responsibility and accountability for preventive health; therefore, supporting mammography screening. Of perhaps the greatest importance, the relationships emphasized positive strengths of African-American culture and invoked the necessity to confront prior negative experiences in health-care systems. These relationships also negated the fears or fatalistic beliefs about breast cancer that had been perpetuated by myths through informal communication and "deliberate silence" from significant others who had previously discouraged or de-emphasized the importance of mammography screening. Further research is needed to determine if the emphasis on cultural heritage was the only motivator that encouraged personal responsibility for mammography screening.

  11. One more hurdle to increasing mammography screening: pubescent, adolescent, and prior mammography screening experiences.

    PubMed

    Thomas, Eileen; Usher, LaToya

    2009-01-01

    Approximately $8.1 billion dollars is spent each year in the United States alone on the treatment of breast cancer. Survival rates are dependent on access to, and utilization of, early detection services. The primary reason for disparity in breast cancer mortality is the delay in time to diagnosis, resulting in poor prognosis. Despite ongoing research to understand barriers to mammography screening, recent studies report a decrease in mammography screening among all racial groups. A qualitative approach was used to elicit information from 36 White non- Hispanic, African-American, Hispanic, and Native American women without a history of breast cancer. Women were invited to share written or audiotape-recorded narratives about experiences pertaining to their breasts and their mammography screening experiences. Major categories identified were: teasing, family norms and values, media/societal influence, body image, and mammography screening experiences. The resulting effects of these experiences left these women with feelings of shame and "conflict" regarding their breasts. The major theme identified was breast conflict. Findings suggest that breast conflict may persist throughout the lifespan and can have a negative influence on a woman's decision to participate in mammography screening. The authors hypothesize that experiences that occur during adolescence pertaining to young girls' breasts can influence a women's body image, which in turn can later in life affect health-seeking behaviors related to mammography screening. These findings have implications for public health practice in planning for breast cancer screening, education, and interventions for women from diverse racial/ethnics groups.

  12. The interaction of perceived risk and benefits and the relationship to predicting mammography adherence in African American women.

    PubMed

    Fair, Alecia Malin; Monahan, Patrick O; Russell, Kathleen; Zhao, Qianqian; Champion, Victoria L

    2012-01-01

    To test the interaction of perceived risk and benefits and how they impact stage of mammography readiness and adherence. Cross-sectional study. Community gathering centers and healthcare clinics across Indiana. 299 African American women who had not had a mammogram in more than 18 months. In-person interviews were used to collect data on sociodemographics, health belief variables, and stage of readiness to undertake mammography screening. Four categories were created to measure the combined magnitude of high or low levels of perceived risk and benefit, with health belief variables linked to modified mammography screening behavior. Perceived risks and benefits, stage of readiness, and mammography adherence. The lowest rate of mammography adherence was in women with a high perceived risk and low perceived benefit toward mammography adherence (26%). The highest rate of adherence was in women with a high perceived benefit and low perceived risk (46%). Differences in mammography adherence were statistically significant between the groups (p = 0.009). The interaction of high perceived risk and low perceived benefits impacted readiness to undergo screening mammography. Reducing disparities in breast cancer diagnosis and survival requires timely and efficient mammography adherence. African American medically underserved women with high perceived risk and low perceived benefits exhibited a reluctance to move forward with mammography adherence. Interventions are needed to increase the perception of mammography benefit and to subsequently reduce breast cancer mortality rates in that population.

  13. Implications of Overdiagnosis: Impact on Screening Mammography Practices

    PubMed Central

    Morris, Elizabeth; Feig, Stephen A.; Drexler, Madeline

    2015-01-01

    Abstract This review article explores the issue of overdiagnosis in screening mammography. Overdiagnosis is the screen detection of a breast cancer, histologically confirmed, that might not otherwise become clinically apparent during the lifetime of the patient. While screening mammography is an imperfect tool, it remains the best tool we have to diagnose breast cancer early, before a patient is symptomatic and at a time when chances of survival and options for treatment are most favorable. In 2015, an estimated 231,840 new cases of breast cancer (excluding ductal carcinoma in situ) will be diagnosed in the United States, and some 40,290 women will die. Despite these data, screening mammography for women ages 40–69 has contributed to a substantial reduction in breast cancer mortality, and organized screening programs have led to a shift from late-stage diagnosis to early-stage detection. Current estimates of overdiagnosis in screening mammography vary widely, from 0% to upwards of 30% of diagnosed cancers. This range reflects the fact that measuring overdiagnosis is not a straightforward calculation, but usually one based on different sets of assumptions and often biased by methodological flaws. The recent development of tomosynthesis, which creates high-resolution, three-dimensional images, has increased breast cancer detection while reducing false recalls. Because the greatest harm of overdiagnosis is overtreatment, the key goal should not be less diagnosis but better treatment decision tools. (Population Health Management 2015;18:S3–S11) PMID:26414384

  14. Characterizing the Mammography Technologist Workforce in North Carolina.

    PubMed

    Henderson, Louise M; Marsh, Mary W; Benefield, Thad; Pearsall, Elizabeth; Durham, Danielle; Schroeder, Bruce F; Bowling, J Michael; Viglione, Cheryl A; Yankaskas, Bonnie C

    2015-12-01

    Mammography technologists' level of training, years of experience, and feedback on technique may play an important role in the breast-cancer screening process. However, information on the mammography technologist workforce is scant. In 2013, we conducted a survey mailed to 912 mammography technologists working in 224 facilities certified by the Mammography Quality Standards Act in North Carolina. Using standard survey methodology, we developed and implemented a questionnaire on the education and training, work experiences, and workplace interactions of mammography technologists. We aggregated responses using survey weights to account for nonresponse. We describe and compare lead (administrative responsibilities) and nonlead (supervised by another technologist) mammography technologist characteristics, testing for differences, using t-tests and χ(2) analysis. A total of 433 mammography technologists responded (survey response rate = 47.5%; 95% confidence interval [CI]: 44.2%-50.7%), including 128 lead and 305 nonlead technologists. Most mammography technologists were non-Hispanic, white women; their average age was 48 years. Approximately 93% of lead and nonlead technologists had mammography-specific training, but <4% had sonography certification, and 3% had MRI certification. Lead technologists reported more years of experience performing screening mammography (P = .02) and film mammography (P = .03), more administrative hours (P < .0001), and more workplace autonomy (P = .002) than nonlead technologists. Nonlead technologists were more likely to report performing diagnostic mammograms (P = .0004) or other breast imaging (P = .001), discuss image quality with a peer (P = .013), and have frequent face-to-face interaction with radiologists (P = .03). Our findings offer insights into mammography technologists' training and work experiences, highlighting variability in characteristics of lead versus nonlead technologists. Copyright © 2015 American College of

  15. Characterizing the mammography technologist workforce in North Carolina

    PubMed Central

    Henderson, Louise M.; Marsh, Mary W.; Benefield, Thad; Pearsall, Elizabeth; Durham, Danielle; Schroeder, Bruce F.; Bowling, J. Michael; Viglione, Cheryl A.; Yankaskas, Bonnie C.

    2016-01-01

    Background Mammography technologists’ level of training, years of experience, and feedback on technique may play an important role in the breast cancer screening process. However, very little information on the mammography technologist workforce exists. Methods In 2013, we conducted a mailed survey to 912 mammography technologists working in 224 Mammography Quality Standards Act accredited facilities in North Carolina. Using standard survey methodology we developed and implemented a questionnaire focused on the education and training, work experiences, and workplace interactions of mammography technologists. We aggregated responses using survey weights to account for non-response. We describe and compare lead (administrative responsibilities) and non-lead (supervised by another technologist) mammography technologist characteristics, testing for differences using t-tests and chi-square tests. Results A total of 433 mammography technologists responded (survey response rate=47.5%; 95% confidence interval:44.2%-50.7%), including 128 lead and 305 non-lead technologists. Most mammography technologists were non-Hispanic, white, females and the average age was 48 years. Approximately 93% of lead and non-lead technologists had mammography specific training but <4% had sonography certification and 3% had MRI certification. Lead technologists reported more years performing screening mammography (p-value=0.02) and film mammography (p-value=0.03), more administrative hours (p-value<0.0001), and more workplace autonomy (p-value=0.002) than non-lead technologists. Non-lead technologists were more likely to report performing diagnostic mammograms (p-value=0.0004) or other breast imaging (p-value=0.001), discuss image quality with a peer (p-value=0.013), and have frequent face-to-face interaction with radiologists (p-value=0.03). Conclusion Our findings offer insights into mammography technologists’ training and work experiences, highlighting variability in technologist

  16. Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography.

    PubMed

    Golatta, Michael; Baggs, Christina; Schweitzer-Martin, Mirjam; Domschke, Christoph; Schott, Sarah; Harcos, Aba; Scharf, Alexander; Junkermann, Hans; Rauch, Geraldine; Rom, Joachim; Sohn, Christof; Heil, Joerg

    2015-04-01

    Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patients´ history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95% CI [0.26;0.36], p < 0.0001) and 0.25 (95% CI [0.2;0.3], p < 0.0001), respectively. Our results showed a high negative predictive value (NPV) of 98%, a high specificity of 85% and a sensitivity of 74% based on the cases with US-guided biopsy. Including the cases where the lesion was seen in a second-look automated 3D-US the sensitivity improved to 84% (NPV = 99%, specificity = 85%). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.

  17. The interaction of perceived risk and benefits and its relationship to predicting mammography adherence in African-American women

    PubMed Central

    Fair, Alecia Malin; Monahan, Patrick O.; Russell, Kathleen; Zhao, Qianqian; Champion, Victoria L.

    2013-01-01

    PURPOSE/OBJECTIVES To test the interaction of perceived risk and benefits on stage of mammography readiness and adherence. DESIGN Cross-sectional study SETTING Community gathering places and health care clinics across a Midwestern state. SAMPLE 299 African-American women who had not had a mammogram in ≥ 18 months. METHODS In-person interviews were used to collect data on sociodemographics, health belief variables and stage of readiness to undertake mammography screening. Four categories were created to measure the combined magnitude of high/low levels of perceived risk and benefit with health belief variables linked to modifying mammography screening behavior. MAIN RESEARCH VARIABLES Perceived risks and benefits, stage of readiness, mammography adherence. FINDINGS The lowest rate of mammography adherence was in women with a high perceived risk and low benefit towards mammography adherence (25.6) compared to women with a high perceived benefit and low risk towards mammography adherence (46.0). Differences in mammography adherence were statistically significant between these groups p=(0.009). CONCLUSIONS The interaction of high perceived risk and low benefits additively effected readiness to undertake screening mammography. IMPLICATIONS FOR NURSING Reducing disparities in breast cancer diagnosis and survival requires timely and efficient mammography adherence. Minority, medically underserved women with perceived high risk and low benefits exhibit immobilization to move forward with mammography adherence when they experience higher perceived risk. Further interventions to increase the perception of benefit of mammography are recommended to reduce breast cancer mortality. PMID:22201655

  18. Obesity, Gynecological Factors, and Abnormal Mammography Follow-Up in Minority and Medically Underserved Women

    PubMed Central

    Wujcik, Debra; Lin, Jin-Mann S.; Grau, Ana; Wilson, Veronica; Champion, Victoria; Zheng, Wei; Egan, Kathleen M.

    2009-01-01

    Abstract Background The relationship between obesity and screening mammography adherence has been examined previously, yet few studies have investigated obesity as a potential mediator of timely follow-up of abnormal (Breast Imaging Reporting and Data System [BIRADS-0]) mammography results in minority and medically underserved patients. Methods We conducted a retrospective cohort study of 35 women who did not return for follow-up >6 months from index abnormal mammography and 41 who returned for follow-up ≤6 months in Nashville, Tennessee. Patients with a BIRADS-0 mammography event in 2003–2004 were identified by chart review. Breast cancer risk factors were collected by telephone interview. Multivariate logistic regression was performed on selected factors with return for diagnostic follow-up. Results Obesity and gynecological history were significant predictors of abnormal mammography resolution. A significantly higher frequency of obese women delayed return for mammography resolution compared with nonobese women (64.7% vs. 35.3%). A greater number of hysterectomized women returned for diagnostic follow-up compared with their counterparts without a hysterectomy (77.8% vs. 22.2%). Obese patients were more likely to delay follow-up >6 months (adjusted OR 4.09, p = 0.02). Conversely, hysterectomized women were significantly more likely to return for timely mammography follow-up ≤6 months (adjusted OR 7.95, p = 0.007). Conclusions Study results suggest that weight status and gynecological history influence patients' decisions to participate in mammography follow-up studies. Strategies are necessary to reduce weight-related barriers to mammography follow-up in the healthcare system including provider training related to mammography screening of obese women. PMID:19558307

  19. Contrast-enhanced spectral mammography vs. mammography and MRI - clinical performance in a multi-reader evaluation.

    PubMed

    Fallenberg, Eva M; Schmitzberger, Florian F; Amer, Heba; Ingold-Heppner, Barbara; Balleyguier, Corinne; Diekmann, Felix; Engelken, Florian; Mann, Ritse M; Renz, Diane M; Bick, Ulrich; Hamm, Bernd; Dromain, Clarisse

    2017-07-01

    To compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) to digital mammography (MG) and magnetic resonance imaging (MRI) in a prospective two-centre, multi-reader study. One hundred seventy-eight women (mean age 53 years) with invasive breast cancer and/or DCIS were included after ethics board approval. MG, CESM and CESM + MG were evaluated by three blinded radiologists based on amended ACR BI-RADS criteria. MRI was assessed by another group of three readers. Receiver-operating characteristic (ROC) curves were compared. Size measurements for the 70 lesions detected by all readers in each modality were correlated with pathology. Reading results for 604 lesions were available (273 malignant, 4 high-risk, 327 benign). The area under the ROC curve was significantly larger for CESM alone (0.84) and CESM + MG (0.83) compared to MG (0.76) (largest advantage in dense breasts) while it was not significantly different from MRI (0.85). Pearson correlation coefficients for size comparison were 0.61 for MG, 0.69 for CESM, 0.70 for CESM + MG and 0.79 for MRI. This study showed that CESM, alone and in combination with MG, is as accurate as MRI but is superior to MG for lesion detection. Patients with dense breasts benefitted most from CESM with the smallest additional dose compared to MG. • CESM has comparable diagnostic performance (ROC-AUC) to MRI for breast cancer diagnostics. • CESM in combination with MG does not improve diagnostic performance. • CESM has lower sensitivity but higher specificity than MRI. • Sensitivity differences are more pronounced in dense and not significant in non-dense breasts. • CESM and MRI are significantly superior to MG, particularly in dense breasts.

  20. Mammography use and its demographic correlates among women in South Korea.

    PubMed

    Suh, Eunyoung E; Park, Sunhee

    2009-06-01

    This study aimed to investigate the mammography rate and its demographic correlates among Korean women in order to provide basic understanding of factors related to the performance of mammography as a method of breast cancer screening. A descriptive secondary analysis was conducted using a national data set from the Korean National Health and Nutrition Examination Survey (KNHNES III) in South Korea. A total number of 2,602 women over 40 years of age were chosen for the analysis. Main research variables included the use of mammography, monthly income, residential area, age, marriage, education, insurance, smoking habits, drinking habits, job type, current health status, and other cancer screening results. Only 30.59% of women adhered to the national guidelines. Monthly income, age, education, insurance, and smoking habits had statistically significant effects on breast cancer screening performance. The demographic correlates of the performance of mammography highlight the fact that not all Korean women, at this stage, are in a socioeconomic or societal position to undergo biannual mammography screening. Targeted and tailored nursing intervention should be implemented in middle- and senior-aged women who lack the ability to access medical resources in South Korea. This will make it possible for marginalized women to utilize cancer screening tests and in turn promote their health.

  1. Quality assurance and quality control in mammography: a review of available guidance worldwide.

    PubMed

    Reis, Cláudia; Pascoal, Ana; Sakellaris, Taxiarchis; Koutalonis, Manthos

    2013-10-01

    Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified were reviewed and a selection was compared for type of guidance (clinical/technical), technology and proposed QA methodologies focusing on dose and image quality (IQ) performance assessment. Fourteen protocols (targeted at conventional and digital mammography) were reviewed. All included recommendations for testing acquisition, processing and display systems associated with mammographic equipment. All guidance reviewed highlighted the importance of dose assessment and testing the Automatic Exposure Control (AEC) system. Recommended tests for assessment of IQ showed variations in the proposed methodologies. Recommended testing focused on assessment of low-contrast detection, spatial resolution and noise. QC of image display is recommended following the American Association of Physicists in Medicine guidelines. The existing QA guidance for mammography is derived from key documents (American College of Radiology and European Union guidelines) and proposes similar tests despite the variations in detail and methodologies. Studies reported on QA data should provide detail on experimental technique to allow robust data comparison. Countries aiming to implement a mammography/QA program may select/prioritise the tests depending on available technology and resources. •An effective QA program should be practical to implement in a clinical setting. •QA should address the various stages of the imaging chain: acquisition, processing and display. •AEC system QC testing is simple to implement and provides information on equipment performance.

  2. Diagnostic accuracy of contrast-enhanced spectral mammography in comparison to conventional full-field digital mammography in a population of women with dense breasts.

    PubMed

    Mori, Miki; Akashi-Tanaka, Sadako; Suzuki, Satoko; Daniels, Murasaki Ikeda; Watanabe, Chie; Hirose, Masanori; Nakamura, Seigo

    2017-01-01

    Contrast-enhanced spectral mammography to compare clinical efficacy of contrast-enhanced spectral mammography (CESM) and conventional digital mammography (MMG) with histopathology as gold standard in dense breasts. A total of 143 breasts of 72 women who underwent CESM and MMG between 2011 and 2014 at Showa University Hospital were analyzed. 129 (90.2 %) of 143 breasts revealed dense breasts on MMG. 58 (40.6 %) of 143 breasts were diagnosed with breast cancer at histopathology. The remaining 85 breasts were diagnosed with benign findings after image assessments and/or core needle biopsy. CESM revealed 8 false-negative cases among 58 breast cancer cases (sensitivity 86.2 %) and 5 false-positive cases (specificity 94.1 %). Accuracy was 90.9 %. Conventional MMG was assessed true positive in 31 of 58 breast cancer cases (sensitivity 53.4 %) and false positive in 12 cases (specificity 85.9 %). Accuracy was 72.7 %. Sensitivity (p < 0.001), specificity (p = 0.016) and accuracy (p < 0.001) were significantly higher on CESM compared to MMG. MMG missed malignancy in 27 breasts. Of these, 25 were dense breasts. Of these 25, 20 (80.0 %) breasts were positive on CESM. These findings suggest that CESM offers superior clinical performance compared to MMG. Use of CESM may decrease false negatives especially for women with dense breasts.

  3. Characteristics of YouTubeTM Videos Related to Mammography.

    PubMed

    Basch, Corey H; Hillyer, Grace Clarke; MacDonald, Zerlina L; Reeves, Rachel; Basch, Charles E

    2015-12-01

    With a monthly total of more than one billion unique visitors, YouTube TM is one of the Internet's most visited websites and contributes to the growing amount of health-related information on the Internet. The purpose of this study was to analyze coverage of mammography screening in popular YouTube TM videos. A total of 173 videos were included in the analysis. Compared with professionally created videos, consumer-created videos had a significantly greater number of comments (>9 comments 38.0% for consumer vs. 11.8% for professional videos, p=<0.001). Videos created by professionals more often portrayed general mammography information (97.1 vs. 88.7%) compared to those created by consumers. The vast majority of videos presented general information (93.6%) related to mammography, and almost two thirds addressed preparing for the test. Less than 20% dealt with other types of examinations. Approximately 30% discussed pain associated with the examination (35.3%) and addressed issues of anxiety (32.4%) and fear (29.5%). Nearly half of the videos presented information about the test results (46.2%). Over 25% covered medical or family history. The majority did not pertain to a specific age group. Future research should focus on analyzing the accuracy of the information in the videos.

  4. Clinical Evaluation of a Digital Mammography Based on Micro-Lithography (Breast Cancer)

    DTIC Science & Technology

    1994-01-20

    7-9, Mannheim. Schnetztor - V flag; 1992: 90-91. 2. Panizza P., Del Maschio A. Digital Luminescence Mammography. Digital Radiography Workshop: Quality...Assurance and Radiation Protection. May 7-9, Mannheim. Schnetztor - Verlag; 1992:66-67. 3. Panizza P., Cattaneo M., Rodighiero M.G., et al. Course on

  5. Does Gender Discrimination Impact Regular Mammography Screening? Findings from the Race Differences in Screening Mammography Study

    PubMed Central

    DAILEY, AMY B.; KASL, STANISLAV V.; JONES, BETH A.

    2011-01-01

    Objective To determine if gender discrimination, conceptualized as a negative life stressor, is a deterrent to adherence to mammography screening guidelines. Methods African American and white women (1451) aged 40–79 years who obtained an index screening mammogram at one of five urban hospitals in Connecticut between October 1996 and January 1998 were enrolled in this study. This logistic regression analysis includes the 1229 women who completed telephone interviews at baseline and follow-up (average 29.4 months later) and for whom the study outcome, nonadherence to age-specific mammography screening guidelines, was determined. Gender discrimination was measured as lifetime experience in seven possible situations. Results Gender discrimination, reported by nearly 38% of the study population, was significantly associated with nonadherence to mammography guidelines in women with annual family incomes of ≥$50,000 (OR 1.99, 95% CI 1.33, 2.98) and did not differ across racial/ethnic group. Conclusions Our findings suggest that gender discrimination can adversely influence regular mammography screening in some women. With nearly half of women nonadherent to screening mammography guidelines in this study and with decreasing mammography rates nationwide, it is important to address the complexity of nonadherence across subgroups of women. Life stressors, such as experiences of gender discrimination, may have considerable consequences, potentially influencing health prevention prioritization in women. PMID:18321171

  6. Does gender discrimination impact regular mammography screening? Findings from the race differences in screening mammography study.

    PubMed

    Dailey, Amy B; Kasl, Stanislav V; Jones, Beth A

    2008-03-01

    ABSTRACT Objective: To determine if gender discrimination, conceptualized as a negative life stressor, is a deterrent to adherence to mammography screening guidelines. African American and white women (1451) aged 40-79 years who obtained an index screening mammogram at one of five urban hospitals in Connecticut between October 1996 and January 1998 were enrolled in this study. This logistic regression analysis includes the 1229 women who completed telephone interviews at baseline and follow-up (average 29.4 months later) and for whom the study outcome, nonadherence to age-specific mammography screening guidelines, was determined. Gender discrimination was measured as lifetime experience in seven possible situations. Gender discrimination, reported by nearly 38% of the study population, was significantly associated with nonadherence to mammography guidelines in women with annual family incomes of > or =$50,000 (OR 1.99, 95% CI 1.33, 2.98) and did not differ across racial/ethnic group. Our findings suggest that gender discrimination can adversely influence regular mammography screening in some women. With nearly half of women nonadherent to screening mammography guidelines in this study and with decreasing mammography rates nationwide, it is important to address the complexity of nonadherence across subgroups of women. Life stressors, such as experiences of gender discrimination, may have considerable consequences, potentially influencing health prevention prioritization in women.

  7. CLINICAL BREAST EXAMINATION SCREENING BY TRAINED LAYWOMEN IN MALAWI INTEGRATED WITH OTHER HEALTH SERVICES.

    PubMed

    Gutnik, L; Lee, C; Msosa, J

    2017-06-01

    Breast cancer awareness and early detection are limited in Sub-Saharan Africa. Resource limitations make screening mammography or clinical breast examination (CBE) by physicians or nurses impractical in many settings. Four laywomen were trained to deliver breast cancer educational talks and conduct CBE. After training, screening was implemented in diverse urban health clinics. Eligible women were 30 years old, with no prior breast cancer or breast surgery, and clinic attendance for reasons other than a breast concern. Women with abnormal CBE were referred to a study surgeon. All palpable masses confirmed by surgeon examination were pathologically sampled. Patients with abnormal screening CBE but normal surgeon examination underwent breast ultrasound confirmation. In addition, 50 randomly selected women with normal screening CBE underwent breast ultrasound, and 45 different women with normal CBE were randomly assigned to surgeon examination. Among 1220 eligible women, 1000 (82%) agreed to CBE. Lack of time (69%) was the commonest reason for refusal. Educational talk attendance was associated with higher CBE participation (83% versus 77%, P ¼ 0.012). Among 1000 women screened, 7% had abnormal CBE. Of 45 women with normal CBE randomised to physician examination, 43 had normal examinations and two had axillary lymphadenopathy not detected by CBE. Sixty of 67 women (90%) with abnormal CBE attended the referral visit. Of these, 29 (48%) had concordant abnormal physician examination. Thirty-one women (52%) had discordant normal physician examination, all of whom also had normal breast ultrasounds. Compared with physician examination, sensitivity for CBE by laywomen was 94% (confidence interval [CI] 79%-99%), specificity 58% (CI, 46%-70%), positive predictive value 48% (CI, 35%-62%), and negative predictive value 96% (CI, 85%-100%). Of 13 women who underwent recommended pathologic sampling of a breast lesion, two had cytologic dysplasia and all others benign Results. CBE

  8. Family/Friend Recommendations and Mammography Intentions: The Roles of Perceived Mammography Norms and Support

    ERIC Educational Resources Information Center

    Molina, Yamile; Ornelas, India J.; Doty, Sarah L.; Bishop, Sonia; Beresford, Shirley A. A.; Coronado, Gloria D.

    2015-01-01

    Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography…

  9. Digital mammography: more microcalcifications, more columnar cell lesions without atypia.

    PubMed

    Verschuur-Maes, Anoek H J; van Gils, Carla H; van den Bosch, Maurice A A J; De Bruin, Peter C; van Diest, Paul J

    2011-09-01

    The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55 159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the mammographic indication for core needle biopsies (density, microcalcifications, or both) and the proportion of columnar cell lesions with or without atypia. The columnar cell lesions were graded according to Schnitt, and we included atypical ductal hyperplasia arising in the context of columnar cell lesions. Proportions were compared using χ(2) tests and prevalence ratios were adjusted for age and hospital. We found that more core needle biopsies per mammogram were taken in the full-field digital mammography period (7.6%) compared with the screen-filmed mammography period (5.0%, P<0.0001). Microcalcifications were more often diagnosed with full-field digital mammography than with screen-filmed mammography (adjusted prevalence ratio: 1.14, confidence interval 95%: 1.01-1.28). Core needle biopsies from the full-field digital mammography era showed more columnar cell lesions (10.8%) than those from the screen-filmed mammography era (4.9%; adjusted prevalence ratio: 1.93, confidence interval 95%: 1.48-2.51), particularly due to more columnar cell lesions without atypia (8.2% respectively 2.8%) while the proportion of columnar cell lesions with atypia remained nearly constant (2.0 vs 2

  10. Experience with a proposed teleradiology system for digital mammography

    NASA Astrophysics Data System (ADS)

    Saulnier, Emilie T.; Mitchell, Robert J.; Abdel-Malek, Aiman A.; Dudding, Kathryn E.

    1995-05-01

    for the mammography images. In conclusion, experience with the testbed is described, as is performance analysis related to selection of network components needed to extend this architecture to clinical evaluation. Recommendations are made as to the critical areas for future work.

  11. Getting started with protocol for quality assurance of digital mammography in the clinical centre of Montenegro.

    PubMed

    Ivanovic, S; Bosmans, H; Mijovic, S

    2015-07-01

    The purpose of this work is (i) to work out a test procedure for quality assurance (QA) in digital mammography with newly released test equipment, including the MagicMax mam multimeter (IBA, Germany) and the anthropomorphic tissue equivalent phantom Mammo AT (IBA, Germany), and (ii) to determine whether a first digital computer radiography (CR) system in Montenegro meets the current European standards. Tested parameters were tube output (µGy mAs(-1)) and output rate (mGy s(-1)), reproducibility and accuracy of tube voltage, half value layer, reproducibility and accuracy of the AEC system, exposure control steps, image receptor's response function, image quality and printer stability test. The evaluated dosimetric quantity is the average glandular dose (AGD) as evaluated from PMMA slabs simulating breast tissue. The main findings are that QA can be organised in Montenegro. (1) All measured parameters are within the range described in European protocols except the tube voltage which deviated more than ± 1 kV. The automatic determination of the HVL was satisfactorily. AGD ranged from 0.66 to 7.02 mGy for PMMA thicknesses from 20 to 70 mm, and is in accordance with literature data. (2) The image quality score as obtained with the anthropomorphic tissue equivalent phantom Mammo AT for the CR system was similar to findings on the authors' conventional screen-film mammography. (3) In clinical practice the mammograms are printed. The CR reader produces images with a pixel size of 43.75 µm, which is compatible with the laser printer (39 µm laser spot spacing). The image processing algorithm embedded in the reader successfully processes mammograms with desirable image brightness and contrast in the printed image. The authors conclude that this first digital mammography system seems a good candidate for breast cancer screening applications. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Does Distance Matter? Distance to Mammography Facilities and Stage at Diagnosis of Breast Cancer in Kentucky

    ERIC Educational Resources Information Center

    Huang, Bin; Dignan, Mark; Han, Daikwon; Johnson, Owen

    2009-01-01

    Background: National and regional data indicate that breast cancer early detection is low in Kentucky, especially rural regions, perhaps because access to mammography services can be problematic. Objective: This study examined the distance between residences of women diagnosed with breast cancer and the nearest mammography facility, as a risk…

  13. Religious beliefs and mammography intention: findings from a qualitative study of a diverse group of American Muslim women.

    PubMed

    Padela, Aasim I; Vu, Milkie; Muhammad, Hadiyah; Marfani, Farha; Mallick, Saleha; Peek, Monica; Quinn, Michael T

    2016-10-01

    Studies suggest that American Muslim women underutilize mammography. While religion has a strong influence upon Muslim health behaviors, scant research has examined how religion-related beliefs inform Muslim women's intention for mammography. Our study identifies and examines such beliefs. Muslim women aged 40 years and older sampled from mosques participated in focus groups and individual interviews. Drawing upon the theory of planned behavior, interviews elicited salient behavioral, normative, and control beliefs regarding mammography and the influence of Islam upon screening intention. Fifty women participated in 6 focus groups and 19 in semistructured interviews, with near-equal numbers of African American, South Asian, and Arab Muslims. Forty-two percent of participants had not had a mammogram within the past 2 years. Across differences in race/ethnicity and mammography status, women voiced four religion-related salient beliefs that inform mammography intention: (1) the perceived duty to care for one's health, (2) religious practices as methods of disease prevention, (3) fatalistic notions about health, and (4) comfort with gender concordant health care. Religious beliefs influence decisions to pursue mammography across the ethnic/racial diversity of Muslim women. Notions about duty to God and the stewardship of one's body appear to enhance mammography intention. Theocentric notions of cure and illness and varied views regarding personal agency also inform decisional frames that impact mammography intention. Given the salience of religion among our participants, religiously tailored messages in interventions have the potential to enhance cancer screening. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Religious Beliefs and Mammography Intention: Findings from a Qualitative Study of a Diverse Group of American Muslim Women

    PubMed Central

    Padela, Aasim I.; Vu, Milkie; Muhammad, Hadiyah; Marfani, Farha; Mallick, Saleha; Peek, Monica; Quinn, Michael T.

    2017-01-01

    Objective Studies suggest that American Muslim women underutilize mammography. While religion has a strong influence upon Muslim health behaviors scant research has examined how religion-related beliefs inform Muslim women’s intention for mammography. Our study identifies and examines such beliefs. Methods Muslim women aged 40 and older sampled from mosques participated in focus groups and individual interviews. Drawing upon the Theory of Planned Behavior, interviews elicited salient behavioral, normative, and control beliefs regarding mammography and the influence of Islam upon screening intention. Results Fifty women participated in 6 focus groups and 19 in semi-structured interviews, with near-equal numbers of African American, South Asian, and Arab Muslims. Forty-two percent of participants had not had a mammogram within the past two years. Across differences in race/ethnicity and mammography status women voiced four religion-related salient beliefs that inform mammography intention: (1) the perceived duty to care for one’s health, (2) religious practices as methods of disease prevention, (3) fatalistic notions about health, and (4) comfort with gender concordant healthcare. Conclusions Religious beliefs influence decisions to pursue mammography across the ethnic/racial diversity of Muslim women. Notions about duty to God and the stewardship of one’s body appear to enhance mammography intention. Theocentric notions of cure and illness and varied views regarding personal agency also inform decisional frames that impact mammography intention. Given the salience of religion among our participants, religiously-tailored messages in interventions have the potential to enhance cancer screening. PMID:27424488

  15. First breast cancer mammography screening program in Mexico: initial results 2005-2006.

    PubMed

    Rodríguez-Cuevas, Sergio; Guisa-Hohenstein, Fernando; Labastida-Almendaro, Sonia

    2009-01-01

    Breast cancer is the most frequent malignant neoplasia worldwide. In emergent countries as Mexico, an increase has been shown in frequency and mortality, unfortunately, most cases in advanced loco-regional stages developed in young women. The success of breast screening in mortality reduction has been observed since 1995 in Western Europe and the United States, where as many as 40% mortality reduction has been achieved. Most countries guidelines recommends an annual or biannual mammography for all women >40 years of age. In 2005, FUCAM, a nonlucrative civil foundation in Mexico join with Mexico City government, initiated the first voluntary mammography screening program for women >40 years of age residing in Mexico City's Federal District. Mammographies were carried out with analogical mammographs in specially designed mobile units and were performed in the area of women's domiciles. This report includes data from the first 96,828 mammographies performed between March 2005 and December 2006. There were 1% of mammographies in Breast Imaging Reporting and Data System 0, 4, or 5 and 208 out of 949 women with abnormal mammographies (27.7%) had breast cancer, a rate of 2.1 per thousand, most of them in situ or stage I (29.4%) or stage II (42.2%) nevertheless 21% of those women with abnormal mammography did not present for further clinical and radiologic evaluation despite being personally notified at their home addresses. The breast cancer rate of Mexican women submitted to screening mammography is lower than in European or North American women. Family history of breast cancer, nulliparity, absence of breast feeding, and increasing age are factors that increase the risk of breast cancer. Most cancers were diagnosed in women's age below 60 years (68.5%) with a mean age of 53.55 corroborating previous data published. It is mandatory to sensitize and educate our population with regard to accepting to visit the Specialized Breast Centers.

  16. Transition From Film to Digital Mammography

    PubMed Central

    van Ravesteyn, Nicolien T.; van Lier, Lisanne; Schechter, Clyde B.; Ekwueme, Donatus U.; Royalty, Janet; Miller, Jacqueline W.; Near, Aimee M.; Cronin, Kathleen A.; Heijnsdijk, Eveline A.M.; Mandelblatt, Jeanne S.; de Koning, Harry J.

    2015-01-01

    Introduction The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides mammograms and diagnostic services for low-income, uninsured women aged 40–64 years. Mammography facilities within the NBCCEDP gradually shifted from plain-film to digital mammography. The purpose of this study is to assess the impact of replacing film with digital mammography on health effects (deaths averted, life-years gained [LYG]), costs (for screening and diagnostics), and number of women reached. Methods NBCCEDP 2010 data and data representative of the program’s target population were used in two established microsimulation models. Models simulated observed screening behavior including different screening intervals (annual, biennial, irregular) and starting ages (40, 50 years) for white, black, and Hispanic women. Model runs were performed in 2012. Results The models predicted 8.0–8.3 LYG per 1,000 film screens for black women, 5.9–7.5 for white women, and 4.0–4.5 for Hispanic women. For all race/ethnicity groups, digital mammography had more LYG than film mammography (2%–4%), but had higher costs (34%–35%). Assuming a fixed budget, 25%–26% fewer women could be served, resulting in 22%–24% fewer LYG if all mammograms were converted to digital. The loss in LYG could be reversed to an 8%–13% increase by only including biennial screening. Conclusions Digital could result in slightly more LYG than film mammography. However, with a fixed budget, fewer women may be served with fewer LYG. Changes in the program, such as only including biennial screening, will increase LYG/screen and could offset the potential decrease in LYG when shifting to digital mammography. PMID:25891052

  17. [Controversial attitude to mammography screening in asymptomatic women between 40 and 50 years of age].

    PubMed

    Frischbier, H J

    1994-01-01

    The results of screening studies conducted in the United States and in Europe in females between the ages of 40 and 50 are analysed. It is shown, that the results of this study on mortality reduction are less favourable, the poorer the technique of mammography (foregoing of general two-view mammography) and the longer the time interval between two mammography screenings. Arguments are presented, that are brought forward when declining to perform general mammography screening in this age group. The author's own results, obtained in the Hamburg mammography screening study, which included from 1971 to 1986 also premenopausal women, show, that the survival rates of patients below 50 years of age with mammographically detected carcinomas of the breast do not differ from those in patients older than 50 years, according to a relevant age group classification. The advances in the technique of mammography in recent years are analysed on the basis of the author's own patient material. It is evident, that the positive predictive value has been doubled, especially in the age group between 40 and 50. An analysis of the distribution of diagnosed noninvasive carcinomas compared with the invasive carcinomas reveals, that particularly this age group has the highest percentage of identification of prognostically favourable carcinoma stages. Further analyses show, why the randomised European mammography studies could not yield a significant mortality rate improvement. A prerequisite for the inclusion of mammography screening in the legally prescribed early detection of carcinoma examinations, however, are the quality controls, whose realisation, in our health system, will have to be confirmed by the German mammography study.

  18. Assessment of automatic exposure control performance in digital mammography using a no-reference anisotropic quality index

    NASA Astrophysics Data System (ADS)

    Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.

    2017-03-01

    Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.

  19. Validation of a condition-specific measure for women having an abnormal screening mammography.

    PubMed

    Brodersen, John; Thorsen, Hanne; Kreiner, Svend

    2007-01-01

    The aim of this study is to assess the validity of a new condition-specific instrument measuring psychosocial consequences of abnormal screening mammography (PCQ-DK33). The draft version of the PCQ-DK33 was completed on two occasions by 184 women who had received an abnormal screening mammography and on one occasion by 240 women who had received a normal screening result. Item Response Theories and Classical Test Theories were used to analyze data. Construct validity, concurrent validity, known group validity, objectivity and reliability were established by item analysis examining the fit between item responses and Rasch models. Six dimensions covering anxiety, behavioral impact, sense of dejection, impact on sleep, breast examination, and sexuality were identified. One item belonging to the dejection dimension had uniform differential item functioning. Two items not fitting the Rasch models were retained because of high face validity. A sick leave item added useful information when measuring side effects and socioeconomic consequences of breast cancer screening. Five "poor items" were identified and should be deleted from the final instrument. Preliminary evidence for a valid and reliable condition-specific measure for women having an abnormal screening mammography was established. The measure includes 27 "good" items measuring different attributes of the same overall latent structure-the psychosocial consequences of abnormal screening mammography.

  20. Clinical breast examination screening by trained laywomen in Malawi integrated with other health services.

    PubMed

    Gutnik, Lily; Lee, Clara; Msosa, Vanessa; Moses, Agnes; Stanley, Christopher; Mzumara, Suzgo; Liomba, N George; Gopal, Satish

    2016-07-01

    Breast cancer awareness and early detection are limited in sub-Saharan Africa. Resource limitations make screening mammography or clinical breast examination (CBE) by physicians or nurses impractical in many settings. We aimed to assess feasibility and performance of CBE by laywomen in urban health clinics in Malawi. Four laywomen were trained to deliver breast cancer educational talks and conduct CBE. After training, screening was implemented in diverse urban health clinics. Eligible women were ≥30 y, with no prior breast cancer or breast surgery, and clinic attendance for reasons other than a breast concern. Women with abnormal CBE were referred to a study surgeon. All palpable masses confirmed by surgeon examination were pathologically sampled. Patients with abnormal screening CBE but normal surgeon examination underwent breast ultrasound confirmation. In addition, 50 randomly selected women with normal screening CBE underwent breast ultrasound, and 45 different women with normal CBE were randomly assigned to surgeon examination. Among 1220 eligible women, 1000 (82%) agreed to CBE. Lack of time (69%) was the commonest reason for refusal. Educational talk attendance was associated with higher CBE participation (83% versus 77%, P = 0.012). Among 1000 women screened, 7% had abnormal CBE. Of 45 women with normal CBE randomized to physician examination, 43 had normal examinations and two had axillary lymphadenopathy not detected by CBE. Sixty of 67 women (90%) with abnormal CBE attended the referral visit. Of these, 29 (48%) had concordant abnormal physician examination. Thirty-one women (52%) had discordant normal physician examination, all of whom also had normal breast ultrasounds. Compared with physician examination, sensitivity for CBE by laywomen was 94% (confidence interval [CI] 79%-99%), specificity 58% (CI, 46%-70%), positive predictive value 48% (CI, 35%-62%), and negative predictive value 96% (CI, 85%-100%). Of 13 women who underwent recommended

  1. Advanced Breast Cancer as Indicator of Quality Mammography

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique

    2003-09-01

    Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is the more important screening tool for detecting early breast cancer. Screening mammography involves taking x-rays from two views from each breast, typically from above (cranial-caudal view, CC) and from an oblique or angled view (mediolateral-oblique, MLO). The purpose of this study was to carry out an exploratory survey of the issue of patients with advanced breast cancer who have had a screening mammography. A general result of the survey is that 22.5% of all patients (102) with advanced breast cancer that participated in the study had previous screening mammography. But we should consider that 10% of breast cancers are not detected by mammography. Only 70% of the family doctors prescribed a diagnostic mammography when the first symptoms were diagnosed.

  2. Cost-effectiveness of strategies to enhance mammography use.

    PubMed

    Fishman, P; Taplin, S; Meyer, D; Barlow, W

    2000-01-01

    To estimate the cost-effectiveness of three strategies to increase breast cancer screening with mammography (reminder postcard, reminder telephone call, and motivational telephone call). Cost accounting for each strategy followed by cost-effectiveness analysis. DATA SOURCE FOR EFFECTIVENESS: Randomized trial of three strategies conducted at Group Health Cooperative of Puget Sound (GHC). Women 50 to 79 years of age who were enrolled in GHC's breast cancer screening program who did not schedule screening mammography within 2 months after it was recommended by letter. Health plan. Marginal cost-effectiveness of each additional woman screened. Because of its high cost (about $26 per call) and intermediate effectiveness, the motivational call was the least cost-effective strategy. If it was assumed that 50% of the women who scheduled mammography after receiving the reminder postcard would have scheduled mammography within 10 months even without it, marginal cost-effectiveness for the postcard among all women was $22 per woman screened versus $92 for the reminder call. Among women with no previous mammography, the marginal cost-effectiveness for the postcard was $70 versus $100 for the reminder call. Among women with no previous mammography, the choice between the reminder postcard and the reminder call was sensitive to assumptions about the percentage of women expected to receive mammography in the absence of other promotional strategies. A simple reminder postcard is the most cost-effective way to increase mammography. Choices about how to promote mammography will ultimately depend on plan values and willingness to invest in promotional strategies that increase participation at higher unit costs.

  3. A methodology to evaluate differential costs of full field digital as compared to conventional screen film mammography in a clinical setting.

    PubMed

    Ciatto, S; Brancato, B; Baglioni, R; Turci, M

    2006-01-01

    The use of full field digital mammography (FFDM) in alternative to conventional screen film mammography (SFM) in the current practice is delayed by the high costs of FFDM. The present study, performed at the Centro per lo Studio e la Prevenzione Oncologica of Florence, using both FFDM and SFM, was aimed at estimating the impact of introducing the new FFDM technique on overall mammography costs. We estimated the differential costs of both methods, based on real expenditures, as provided by the administrative department, and on radiologists, radiographers and other staff's working time. Two different workload scenarios (5000 and 10,000 tests/year per mammography equipment) were considered. Common costs of both techniques were censored for study purpose. Beside a higher cost due to purchase and hire/leasing costs of equipment, FFDM implies a greater workload for radiologists (reading time almost doubled). SFM implies a greater workload for the administrative staff to run the archive and for loading/unloading films of the roller viewer, whereas no different workload has been observed for radiographers. Overall FFDM costs 24.22-26.46 for examination more than SFM for the 5000 tests scenario and 9.91-12.15 more for the 10,000 tests scenario. Although present study estimates cannot easily be generalised to any local setting, the model for cost calculation is easy to be exported to another scenario by applying different local parameters. The advantages made available by FFDM (computerised data recording, tele-transmission, tele-reporting, tele-consulting, automatic display on monitor of previous exams and use of CAD) may justify the higher cost, but a limited reduction in purchase and assistance costs could easily allow a turnover, with FFDM being more convenient than SFM even on the cost side.

  4. Does performance of breast self-exams increase the probability of using mammography: evidence from Malaysia.

    PubMed

    Dunn, Richard A; Tan, Andrew; Samad, Ismail

    2010-01-01

    Breast self-examination (BSE) was evaluated to see if it is a significant predictor of mammography. The decisions of females above age 40 in Malaysia to test for breast cancer using BSE and mammography are jointly modeled using a bivariate probit so that unobserved attributes affecting mammography usage are also allowed to affect BSE. Data come from the Malaysia Non-Communicable Disease Surveillance-1, which was collected between September 2005 and February 2006. Having ever performed BSE is positively associated with having ever undergone mammography among Malay (adjusted OR=7.343, CI=2.686, 20.079) and Chinese (adjusted OR=3.466, CI=1.330, 9.031) females after adjusting for household income, education, marital status and residential location. Neither relationship is affected by jointly modelling the decision problem. Although the association is also positive for Indian females when mammography is modelled separately (adjusted OR=5.959, CI=1.546 - 22.970), the relationship is reversed when both decisions are modelled separately. De-emphasizing BSE in Malaysia may reduce mammography screening among a large proportion of the population. Previous work on the issue in developed countries may not apply to nations with limited resources.

  5. Cost-effectiveness comparison of five interventions to increase mammography screening.

    PubMed

    Saywell, R M; Champion, V L; Skinner, C S; McQuillen, D; Martin, D; Maraj, M

    1999-11-01

    Mammography is the primary method used for breast cancer screening. However, compliance with recommended screening practices is still below acceptable levels. This study examined the cost-effectiveness of five combinations of physician recommendation and telephone or in-person individualized counseling strategies for increasing compliance with mammography. There were 808 participants who were randomly assigned to one of six groups. A logistic regression model with compliance as the dependent variable and group as the independent variable was used to test for significant differences and a ratio of cost to improvement in mammogram compliance evaluated the cost-effectiveness. Three of the interventions (in-person, telephone plus letter, and in-person plus letter) had significantly better compliance rates compared with the control, physician letter, or telephone alone. However, when considering costs, only one emerged as the superior strategy. The cost-effectiveness ratios for the five interventions show that telephone-plus-letter is the most cost-effective strategy, achieving a 35.6% mammography compliance at a marginal cost of $0.78 per 1% increase in women screened. A tailored phone prompt and physician reminder is an effective and economical intervention to increase mammography. Future research should confirm this finding and address its applicability to practice. Copyright 1999 American Health Foundation and Academic Press.

  6. Feasibility study of a TIMEPIX detector for mammography applications

    NASA Astrophysics Data System (ADS)

    Ávila, Carlos A.; Mendoza, Luis M.; Roque, Gerardo A.; Loaiza, Leonardo; Racedo, Jorge; Rueda, Roberto

    2017-11-01

    We present a comparison study of two X-ray systems for mammography imaging. One is a SELENIA clinical system and the second is a TIMEPIX based system. The aim of the study is to determine the capability of a TIMEPIX detector for mammography applications. We first compare signal to noise ratio (SNR) of X-ray images of Al2O3 spheres with diameters of 0.16mm, 0.24mm and 0.32mm, of a commercial mammography accreditation phantom CIRS015, obtained with each system. Then, we make a similar comparison for a second phantom built with Hydroxyapatite crystals with different morphology and sizes ranging between 0.15mm and 0.83mm, which are embedded within the same block of PMMA of the CIRS015 phantom. Our study allows us to determine the minimum size of Al2O3 spheres on the order of 240μm, with 33% lower SNR for the TIMEPIX system as compared to the SELENIA system. When comparing the images of Hydroxyapatite crystals from both systems, the minimum size observed is about 300μm, with 23% lower SNR for TIMEPIX.

  7. Trimodel Mammography with Perfect Coregistration

    DTIC Science & Technology

    2017-02-01

    background, the major confounding factor in reading mammography; the imaging characteristics suggest that this contrast mechanism would be preferable...image with enhanced edges and reduced anatomical background, the major confounding factor in reading mammography; the imaging characteristics suggest...subjects, vertebrate animals , biohazards, and/or select agents Describe significant deviations, unexpected outcomes, or changes in approved protocols

  8. High-speed large angle mammography tomosynthesis system

    NASA Astrophysics Data System (ADS)

    Eberhard, Jeffrey W.; Staudinger, Paul; Smolenski, Joe; Ding, Jason; Schmitz, Andrea; McCoy, Julie; Rumsey, Michael; Al-Khalidy, Abdulrahman; Ross, William; Landberg, Cynthia E.; Claus, Bernhard E. H.; Carson, Paul; Goodsitt, Mitchell; Chan, Heang-Ping; Roubidoux, Marilyn; Thomas, Jerry A.; Osland, Jacqueline

    2006-03-01

    A new mammography tomosynthesis prototype system that acquires 21 projection images over a 60 degree angular range in approximately 8 seconds has been developed and characterized. Fast imaging sequences are facilitated by a high power tube and generator for faster delivery of the x-ray exposure and a high speed detector read-out. An enhanced a-Si/CsI flat panel digital detector provides greater DQE at low exposure, enabling tomo image sequence acquisitions at total patient dose levels between 150% and 200% of the dose of a standard mammographic view. For clinical scenarios where a single MLO tomographic acquisition per breast may replace the standard CC and MLO views, total tomosynthesis breast dose is comparable to or below the dose in standard mammography. The system supports co-registered acquisition of x-ray tomosynthesis and 3-D ultrasound data sets by incorporating an ultrasound transducer scanning system that flips into position above the compression paddle for the ultrasound exam. Initial images acquired with the system are presented.

  9. Short-Term Outcomes of Screening Mammography Using Computer-Aided Detection

    PubMed Central

    Fenton, Joshua J.; Xing, Guibo; Elmore, Joann G.; Bang, Heejung; Chen, Steven L.; Lindfors, Karen K.; Baldwin, Laura-Mae

    2013-01-01

    Background Computer-aided detection (CAD) has rapidly diffused into screening mammography practice despite limited and conflicting data on its clinical effect. Objective To determine associations between CAD use during screening mammography and the incidence of ductal carcinoma in situ (DCIS) and invasive breast cancer, invasive cancer stage, and diagnostic testing. Design Retrospective cohort study. Setting Medicare program. Participants Women aged 67 to 89 years having screening mammography between 2001 and 2006 in U.S. SEER (Surveillance, Epidemiology and End Results) regions (409 459 mammograms from 163 099 women). Measurements Incident DCIS and invasive breast cancer within 1 year after mammography, invasive cancer stage, and diagnostic testing within 90 days after screening among women without breast cancer. Results From 2001 to 2006, CAD prevalence increased from 3.6% to 60.5%. Use of CAD was associated with greater DCIS incidence (adjusted odds ratio [OR], 1.17 [95% CI, 1.11 to 1.23]) but no difference in invasive breast cancer incidence (adjusted OR, 1.00 [CI, 0.97 to 1.03]). Among women with invasive cancer, CAD was associated with greater likelihood of stage I to II versus III to IV cancer (adjusted OR, 1.27 [CI, 1.14 to 1.41]). In women without breast cancer, CAD was associated with increased odds of diagnostic mammography (adjusted OR, 1.28 [CI, 1.27 to 1.29]), breast ultrasonography (adjusted OR, 1.07 [CI, 1.06 to 1.09]), and breast biopsy (adjusted OR, 1.10 [CI, 1.08 to 1.12]). Limitation Short follow-up for cancer stage, potential unmeasured confounding, and uncertain generalizability to younger women. Conclusion Use of CAD during screening mammography among Medicare enrollees is associated with increased DCIS incidence, the diagnosis of invasive breast cancer at earlier stages, and increased diagnostic testing among women without breast cancer. Primary Funding Source Center for Healthcare Policy and Research, University of California, Davis. PMID

  10. Web-based mammography audit feedback.

    PubMed

    Geller, Berta M; Ichikawa, Laura; Miglioretti, Diana L; Eastman, David

    2012-06-01

    Interpreting screening mammography accurately is challenging and requires ongoing education to maintain and improve interpretative skills. Recognizing this, many countries with organized breast screening programs have developed audit and feedback systems using national performance data to help radiologists assess and improve their skills. We developed and tested an interactive Website to provide screening and diagnostic mammography audit feedback with comparisons to national and regional benchmarks. Radiologists who participate in three Breast Cancer Surveillance Consortium registries in the United States were invited during 2009 and 2010 to use a Website that provides tabular and graphical displays of mammography audit reports with comparisons to national and regional performance measures. We collected data about the use and perceptions of the Website. Thirty-five of 111 invited radiologists used the Website from one to five times in a year. The most popular measure was sensitivity for both screening and diagnostic mammography, whereas a table with all measures was the most visited page. Of the 13 radiologists who completed the postuse survey, all found the Website easy to use and navigate, 11 found the benchmarks useful, and nine reported that they intended to improve a specific outcome measure that year. An interactive Website to provide customized mammography audit feedback reports to radiologists has the potential to be a powerful tool in improving interpretive performance. The conceptual framework of customized audit feedback reports can also be generalized to other imaging tests.

  11. Deep learning in mammography and breast histology, an overview and future trends.

    PubMed

    Hamidinekoo, Azam; Denton, Erika; Rampun, Andrik; Honnor, Kate; Zwiggelaar, Reyer

    2018-07-01

    Recent improvements in biomedical image analysis using deep learning based neural networks could be exploited to enhance the performance of Computer Aided Diagnosis (CAD) systems. Considering the importance of breast cancer worldwide and the promising results reported by deep learning based methods in breast imaging, an overview of the recent state-of-the-art deep learning based CAD systems developed for mammography and breast histopathology images is presented. In this study, the relationship between mammography and histopathology phenotypes is described, which takes biological aspects into account. We propose a computer based breast cancer modelling approach: the Mammography-Histology-Phenotype-Linking-Model, which develops a mapping of features/phenotypes between mammographic abnormalities and their histopathological representation. Challenges are discussed along with the potential contribution of such a system to clinical decision making and treatment management. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  12. Turkish translation and adaptation of Champion's Health Belief Model Scales for breast cancer mammography screening.

    PubMed

    Yilmaz, Meryem; Sayin, Yazile Yazici

    2014-07-01

    To examine the translation and adaptation process from English to Turkish and the validity and reliability of the Champion's Health Belief Model Scales for Mammography Screening. Its aim (1) is to provide data about and (2) to assess Turkish women's attitudes and behaviours towards mammography. The proportion of women who have mammography is lower in Turkey. The Champion's Health Belief Model Scales for Mammography Screening-Turkish version can be helpful to determine Turkish women's health beliefs, particularly about mammography. Cross-sectional design was used to collect survey data from Turkish women: classical measurement method. The Champion's Health Belief Model Scales for Mammography Screening was translated from English to Turkish. Again, it was back translated into English. Later, the meaning and clarity of the scale items were evaluated by a bilingual group representing the culture of the target population. Finally, the tool was evaluated by two bilingual professional researchers in terms of content validity, translation validity and psychometric estimates of the validity and reliability. The analysis included a total of 209 Turkish women. The validity of the scale was confirmed by confirmatory factor analysis and criterion-related validity testing. The Champion's Health Belief Model Scales for Mammography Screening aligned to four factors that were coherent and relatively independent of each other. There was a statistically significant relationship among all of the subscale items: the positive and high correlation of the total item test score and high Cronbach's α. The scale has a strong stability over time: the Champion's Health Belief Model Scales for Mammography Screening demonstrated acceptable preliminary values of reliability and validity. The Champion's Health Belief Model Scales for Mammography Screening is both a reliable and valid instrument that can be useful in measuring the health beliefs of Turkish women. It can be used to provide data

  13. Quality assurance and ergonomics in the mammography department.

    PubMed

    Reynolds, April

    2014-01-01

    Quality assurance (QA) in mammography is a system of checks that helps ensure the proper functioning of imaging equipment and processes. Ergonomics is a scientific approach to arranging the work environment to reduce the risk of work-related injuries while increasing staff productivity and job satisfaction. This article reviews both QA and ergonomics in mammography and explains how they work together to create a safe and healthy environment for radiologic technologists and their patients. QA and quality control requirements in mammography are discussed, along with ergonomic best practices in the mammography setting.

  14. Current Realities of Delivering Mammography Services in the Community: Do Challenges with Staffing and Scheduling Exist?

    PubMed Central

    D'Orsi, Carl; Tu, Shin-Ping; Nakano, Connie; Carney, Patricia A.; Abraham, Linn A.; Taplin, Stephen H.; Hendrick, R. Edward; Cutter, Gary R.; Berns, Eric; Barlow, William E.; Elmore, Joann G.

    2011-01-01

    PURPOSE To evaluate the current (2001–2002) capacity of community-based mammography facilities to deliver screening and diagnostic services in the United States. MATERIALS AND METHODS Institutional review board approvals and patient consent were obtained. A mailed survey was sent to 53 eligible mammography facilities in three states (Washington, New Hampshire, and Colorado). Survey questions assessed equipment and staffing availability, as well as appointment waiting times for screening and diagnostic mammography services. Criterion-related content and construct validity were obtained first by means of a national advisory committee of academic, scientific, and clinical colleagues in mammography that reviewed literature on existing surveys and second by pilot testing a series of draft surveys among community mammography facilities not inclusive of the study facilities. The final survey results were independently double entered into a relational database with programmed data checks. The data were sent encrypted by means of file transfer protocol to a central analytical center at Group Health Cooperative. A two-sided P value with α = .05 was considered to show statistical significance in all analyses. RESULTS Forty-five of 53 eligible mammography facilities (85%) returned the survey. Shortages of radiologists relative to the mammographic volume were found in 44% of mammography facilities overall, with shortages of radiologists higher in not-for-profit versus for-profit facilities (60% vs 28% reported). Shortages of Mammography Quality Standards Act–qualified technologists were reported by 20% of facilities, with 46% reporting some level of difficulty in maintaining qualified technologists. Waiting times for diagnostic mammography ranged from less than 1 week to 4 weeks, with 85% performed within 1 week. Waiting times for screening mammography ranged from less than 1 week to 8 weeks, with 59% performed between 1 week and 4 weeks. Waiting times for both diagnostic

  15. Monte Carlo Simulation of X-Ray Spectra in Mammography and Contrast-Enhanced Digital Mammography Using the Code PENELOPE

    NASA Astrophysics Data System (ADS)

    Cunha, Diego M.; Tomal, Alessandra; Poletti, Martin E.

    2013-04-01

    In this work, the Monte Carlo (MC) code PENELOPE was employed for simulation of x-ray spectra in mammography and contrast-enhanced digital mammography (CEDM). Spectra for Mo, Rh and W anodes were obtained for tube potentials between 24-36 kV, for mammography, and between 45-49 kV, for CEDM. The spectra obtained from the simulations were analytically filtered to correspond to the anode/filter combinations usually employed in each technique (Mo/Mo, Rh/Rh and W/Rh for mammography and Mo/Cu, Rh/Cu and W/Cu for CEDM). For the Mo/Mo combination, the simulated spectra were compared with those obtained experimentally, and for spectra for the W anode, with experimental data from the literature, through comparison of distribution shape, average energies, half-value layers (HVL) and transmission curves. For all combinations evaluated, the simulated spectra were also compared with those provided by different models from the literature. Results showed that the code PENELOPE provides mammographic x-ray spectra in good agreement with those experimentally measured and those from the literature. The differences in the values of HVL ranged between 2-7%, for anode/filter combinations and tube potentials employed in mammography, and they were less than 5% for those employed in CEDM. The transmission curves for the spectra obtained also showed good agreement compared to those computed from reference spectra, with average relative differences less than 12% for mammography and CEDM. These results show that the code PENELOPE can be a useful tool to generate x-ray spectra for studies in mammography and CEDM, and also for evaluation of new x-ray tube designs and new anode materials.

  16. Construction of mammographic examination process ontology using bottom-up hierarchical task analysis.

    PubMed

    Yagahara, Ayako; Yokooka, Yuki; Jiang, Guoqian; Tsuji, Shintarou; Fukuda, Akihisa; Nishimoto, Naoki; Kurowarabi, Kunio; Ogasawara, Katsuhiko

    2018-03-01

    Describing complex mammography examination processes is important for improving the quality of mammograms. It is often difficult for experienced radiologic technologists to explain the process because their techniques depend on their experience and intuition. In our previous study, we analyzed the process using a new bottom-up hierarchical task analysis and identified key components of the process. Leveraging the results of the previous study, the purpose of this study was to construct a mammographic examination process ontology to formally describe the relationships between the process and image evaluation criteria to improve the quality of mammograms. First, we identified and created root classes: task, plan, and clinical image evaluation (CIE). Second, we described an "is-a" relation referring to the result of the previous study and the structure of the CIE. Third, the procedural steps in the ontology were described using the new properties: "isPerformedBefore," "isPerformedAfter," and "isPerformedAfterIfNecessary." Finally, the relationships between tasks and CIEs were described using the "isAffectedBy" property to represent the influence of the process on image quality. In total, there were 219 classes in the ontology. By introducing new properties related to the process flow, a sophisticated mammography examination process could be visualized. In relationships between tasks and CIEs, it became clear that the tasks affecting the evaluation criteria related to positioning were greater in number than those for image quality. We developed a mammographic examination process ontology that makes knowledge explicit for a comprehensive mammography process. Our research will support education and help promote knowledge sharing about mammography examination expertise.

  17. 2-D or 3-D Mammography? The Future of Breast Cancer Detection

    MedlinePlus

    ... D or 3-D Mammography?: The Future of Breast Cancer Detection NIH-supported clinical trial tests diagnostic imaging ... new trial may be the answer for finding breast cancer in women who don’t have symptoms. The ...

  18. From facts to arguments: A study of the 2014 Swiss controversy over systematic mammography screening.

    PubMed

    Perrenoud, Caroline; Stiefel, Friedrich; Bourquin, Céline

    2018-06-01

    The Swiss Medical Board (SMB) has recently revived the controversy over mammography screening by recommending to stop the introduction of new systematic mammography screening programs. This study aimed to examine the Swiss media coverage of the release of the SMB report. The dataset consisted of 25 newspaper and "medical magazine" articles, and TV/radio interviews. The analytic approach was based on argumentation theory. Authority and community arguments were the most frequent types of arguments. With respect to authority arguments, stakeholders for instance challenged or supported the expertise of the SMB by referring to the competence of external figures of authority. Community arguments were based on common values such as life (saved thanks to systematic mammography screening) and money (costs associated with unnecessary care induced by systematic mammography screening). The efficiency of mammography screening which was the key issue of the debate appeared to be largely eluded, and the question of what women should do endures. While interpersonal and interprofessional communication has become a major topic of interest in the medical community, it appears that media communication on mammography screening is still rather ineffective. We call in particular for a more fact-based discussion. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Factors influencing the mammography utilization among Taiwanese women with intellectual disabilities, a nationwide population-based study.

    PubMed

    Lai, Hsien-Tang; Kung, Pei-Tseng; Tsai, Wen-Chen

    2014-12-01

    Women with intellectual disabilities (ID) have cognitive impairment and communication difficulties; for both caregivers and clinical personnel, discovering the early symptoms of breast cancer among women with ID is challenging. The mammography utilization rate of women with ID was significantly lower than that of women in the general population. This study employed a 2008 database of people with disabilities in Taiwan as a research target and analyzed the mammography utilization rate of women with ID aged 50–69 years. In addition, relevant factors influencing mammography utilization among women with ID were also investigated. A total of 4370 participants were recruited and the majority were illiterate or had elementary-level educations (82.27%). The majority of the participants had ID that was more severe than mild (83.80%). The mammography utilization rate of women with ID was 4.32%, which was significantly lower than that of women in the general population (12%). The mammography utilization rate among women with ID who were married, had higher education levels, and had been diagnosed with cancer, diabetes, or mild ID was significantly higher. However, the mammography utilization rate among women with ID, who had elementary-level educations or were illiterate, was only 4.03%. The utilization rate among women with profound ID was only 2.65%. Women with ID who had undergone pap smears or had utilized adult preventive health services demonstrated a significantly higher mammography utilization rate. This study identified that education level, a diagnosis of diabetes, and the application of pap smears or adult preventive health services were primary factors that influenced the mammography utilization rate among women with ID. This study also observed that in Taiwan, the mammography utilization rate of women with ID was lower than that of pap smears and adult preventive health services, and was only half of that of people with disabilities. An unequal situation

  20. [Comparison of dignity determination of mammographic microcalcification with two systems for digital full-field mammography with different detector resolution: a retrospective clinical study].

    PubMed

    Schulz-Wendtland, R; Hermann, K-P; Adamietz, B; Meier-Meitinger, M; Wenkel, E; Lell, M; Anders, K; Uder, M

    2011-02-01

    The aim of this retrospective clinical study was to compare the diagnostic accuracy of the novel 50 µm FFDM (full-field digital mammography) system (DR) with an established 70 µm system (DR) in the differential diagnosis between benign and malignant clusters of microcalcification (n=50) (BI-RADS™ classification 4/5) and to assess the possible incremental value of the 50 µm pixel-pitch on specificity. From March 2009 to September 2009, 50 patients underwent full-field digital mammography (FFDM) (detector resolution 70 µm) (Novation, Siemens, Erlangen, Germany). As there were suspicious signs of microcalcification classified with BI-RADS™ 4/5 after diagnosis and preoperative wire localization, control images were made with the new FFDM system (detector: resolution 50 µm) (Amulet, Fujifilm, Tokyo, Japan) with the same exposure parameters. The diagnosis was determined after the operation by five radiologists with different experience in digital mammography from randomly distributed mediolateral views (monitor reading) whose results were correlated with the final histology of all lesions. Histopathology revealed 19 benign and 31 malignant lesions in 50 patients after open biopsy. The results of the five readers showed a higher sensitivity of the new FFDM system (80.0%) in the ability to recognize malignant microcalcification in comparison to the established system (74.8%). The specificity (75.8 versus 71.6%) was slightly higher for the new system but these results were not statistically significant (p<0.001). Considering the diagnostic accuracy, the new system (detector: resolution 50 µm) was also slightly superior to the well-known system (detector: resolution 70 µm) (80.1% versus 76.4%). Our study has shown that the new full-field digital mammography system using the novel detector compared with the already established FFDM system with respect to the assessment of microcalcification is at least equivalent.

  1. Breast cancer risk from different mammography screening practices.

    PubMed

    Bijwaard, Harmen; Brenner, Alina; Dekkers, Fieke; van Dillen, Teun; Land, Charles E; Boice, John D

    2010-09-01

    Mammography screening is an accepted procedure for early detection of breast tumors among asymptomatic women. Since this procedure involves the use of X rays, it is itself potentially carcinogenic. Although there is general consensus about the benefit of screening for older women, screening practices differ between countries. In this paper radiation risks for these different practices are estimated using a new approach. We model breast cancer induction by ionizing radiation in a cohort of patients exposed to frequent X-ray examinations. The biologically based, mechanistic model provides a better foundation for the extrapolation of risks to different mammography screening practices than empirical models do. The model predicts that the excess relative risk (ERR) doubles when screening starts at age 40 instead of 50 and that a continuation of screening at ages 75 and higher carries little extra risk. The number of induced fatal breast cancers is estimated to be considerably lower than derived from epidemiological studies and from internationally accepted radiation protection risks. The present findings, if used in a risk-benefit analysis for mammography screening, would be more favorable to screening than estimates currently recommended for radiation protection. This has implications for the screening ages that are currently being reconsidered in several countries.

  2. The knowledge and attitudes of breast self-examination and mammography in a group of women in a rural area in western Turkey.

    PubMed

    Dündar, Pinar Erbay; Ozmen, Dilek; Oztürk, Beyhan; Haspolat, Gökçe; Akyildiz, Filiz; Coban, Sümeyra; Cakiroglu, Gamze

    2006-02-24

    Breast cancer appears to be a disease of both the developing and developed worlds. Among Turkish women, breast cancer is the second leading cause of cancer-related deaths. The aims of this cross-sectional study were to determine levels of knowledge about breast cancer and to evaluate health beliefs concerning the model that promotes breast self- examination (BSE) and mammography in a group of women aged 20-64 in a rural area of western Turkey. 244 women were recruited by means of cluster sampling in this study. The questionnaire consisted of sociodemographic variables, a risk factors and signs of breast cancer form and the adapted version of Champion's Health Belief Model Scale (CHBMS). Bivariate correlation analysis, Chi square test, Mann-Whitney U test and logistic regression analysis were performed throughout the data analysis. The mean age of the women was 37.7 +/- 13.7. 49.2% of women were primary school graduates, 67.6% were married. Although 76.6% of the women in this study reported that they had heard or read about breast cancer, our study revealed that only 56.1% of them had sufficient knowledge of breast cancer, half of whom had acquired the information from health professionals. Level of breast cancer knowledge was the only variable significantly associated with the BSE and mammography practice (p = 0.011, p = 0.007). BSE performers among the study group were more likely to be women who exhibited higher confidence and perceived greater benefits from BSE practice, and those who perceived fewer barriers to BSE performance and possessed knowledge of breast cancer. By using the CHBMS constructs for assessment, primary health care providers can more easily understand the beliefs that influence women's BSE and mammography practice.

  3. The length of time necessary to break even after converting to digital mammography.

    PubMed

    Hiatt, M D; Carr, J J; Manning, R L

    2000-01-01

    The cost differences between film-based mammography (FBM) and digital mammography (DM) were estimated after discussions with hospital personnel and industry representatives. Human resource costs were not included. The fixed cost of FBM per machine was estimated to be $50,000 and the variable cost $4.60 per examination. The fixed cost of DM per machine was estimated to be $102,000 and the variable cost $0.10 per examination. The total number of examinations required to break even was therefore 11,556. At a rate of 15 examinations per machine per day and with 251 working days per year, it would take 3.1 years to break even. In the first year after the break-even point had been attained, $16,943 would be saved for every 3765 examinations performed. Extrapolating to the USA as a whole, in which 23 million mammographic examinations are performed each year, suggests that the annual savings from going filmless would be more than $103 million.

  4. Utilization of screening mammography in New Hampshire: a population-based assessment.

    PubMed

    Carney, Patricia A; Goodrich, Martha E; Mackenzie, Todd; Weiss, Julia E; Poplack, Steven P; Wells, Wendy S; Titus-Ernstoff, Linda

    2005-10-15

    The objective of screening mammography is to identify breast carcinoma early, which requires routine screening. Although self-report data indicate that screening utilization is high, the results of this population-based assessment indicated that utilization is lower than reported previously. The authors compared New Hampshire population data from the 2000 Census with clinical encounter data for the corresponding time obtained from the New Hampshire Mammography Network, a mammography registry that captures approximately 90% of the mammograms performed in participating New Hampshire facilities. The results showed that approximately 36% of New Hampshire women either never had a mammogram or had not had a mammogram in > 27 months (irregular screenees), and older women (80 yrs and older) were less likely to be screened (79% unscreened/underscreened) compared with younger women (ages 40-69 yrs; 28-32% unscreened/underscreened). Of the screened women, 44% were adhering to an interval of 14 months, and 21% were adhering within 15 months and 26 months. The remaining 35% of the women had 1 or 2 mammograms and did not return within 27 months. Routine mammography screening may be occurring less often than believed when survey data alone are used. An important, compelling concern is the reason women had one or two mammograms only and then did not return for additional screening. This area deserves additional research. Copyright 2005 American Cancer Society

  5. Mammography screening credit card and compliance.

    PubMed

    Schapira, D V; Kumar, N B; Clark, R A; Yag, C

    1992-07-15

    Screening for breast cancer using mammography has been shown to be effective in reducing mortality from breast cancer. The authors attempted to determine if use of a wallet-size plastic screening "credit" card would increase participants' compliance for subsequent mammograms when compared with traditional methods of increasing compliance. Two hundred and twenty consecutive women, ages 40-70 years, undergoing their first screening mammography were recruited and assigned randomly to four groups receiving (1) a reminder plastic credit card (2) reminder credit card with written reminder; (3) appointment card; and (4) verbal recommendation. Return rates of the four groups were determined after 15 months. The return rate for subsequent mammograms was significantly higher for participants (72.4%) using the credit card than for participants (39.8%) exposed to traditional encouragement/reminders (P less than 0.0001). The credit card was designed to show the participant's screening anniversary, and the durability of the card may have been a factor in increasing the return rate. The use of reminder credit cards may increase compliance for periodic screening examinations for other cancers and other chronic diseases.

  6. Bilateral Contrast-enhanced Dual-Energy Digital Mammography: Feasibility and Comparison with Conventional Digital Mammography and MR Imaging in Women with Known Breast Carcinoma

    PubMed Central

    Dershaw, D. David; Sung, Janice S.; Heerdt, Alexandra S.; Thornton, Cynthia; Moskowitz, Chaya S.; Ferrara, Jessica; Morris, Elizabeth A.

    2013-01-01

    Purpose To determine feasibility of performing bilateral dual-energy (DE) contrast agent–enhanced (CE) digital mammography and to evaluate its performance compared with conventional digital mammography and breast magnetic resonance (MR) imaging in women with known breast cancer. Materials and Methods This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained. Patient accrual began in March 2010 and ended in August 2011. Mean patient age was 49.6 years (range, 25–74 years). Feasibility was evaluated in 10 women with newly diagnosed breast cancer who were injected with 1.5 mL per kilogram of body weight of iohexol and imaged between 2.5 and 10 minutes after injection. Once feasibility was confirmed, 52 women with newly diagnosed cancer who had undergone breast MR imaging gave consent to undergo DE CE digital mammography. Positive findings were confirmed with pathologic findings. Results Feasibility was confirmed with no adverse events. Visualization of tumor enhancement was independent of timing after contrast agent injection for up to 10 minutes. MR imaging and DE CE digital mammography both depicted 50 (96%) of 52 index tumors; conventional mammography depicted 42 (81%). Lesions depicted by using DE CE digital mammography ranged from 4 to 67 mm in size (median, 17 mm). DE CE digital mammography depicted 14 (56%) of 25 additional ipsilateral cancers compared with 22 (88%) of 25 for MR imaging. There were two false-positive findings with DE CE digital mammography and 13 false-positive findings with MR imaging. There was one contralateral cancer, which was not evident with either modality. Conclusion Bilateral DE CE digital mammography was feasible and easily accomplished. It was used to detect known primary tumors at a rate comparable to that of MR imaging and higher than that of conventional digital mammography. DE CE digital mammography had a lower sensitivity for detecting additional ipsilateral

  7. Incremental Role of Mammography in the Evaluation of Gynecomastia in Men Who Have Undergone Chest CT.

    PubMed

    Sonnenblick, Emily B; Salvatore, Mary; Szabo, Janet; Lee, Karen A; Margolies, Laurie R

    2016-08-01

    The purpose of this study was to determine whether additional breast imaging is clinically valuable in the evaluation of patients with gynecomastia incidentally observed on CT of the chest. In a retrospective analysis, 62 men were identified who had a mammographic diagnosis of gynecomastia and had also undergone CT within 8 months (median, 2 months). We compared the imaging findings of both modalities and correlated them with the clinical outcome. Gynecomastia was statistically significantly larger on mammograms than on CT images; however, there was a high level of concordance in morphologic features and distribution of gynecomastia between mammography and CT. In only one case was gynecomastia evident on mammographic but not CT images, owing to cachexia. Two of the 62 men had ductal carcinoma, which was obscured by gynecomastia. Both of these patients had symptoms suggesting malignancy. The appearance of gynecomastia on CT scans and mammograms was highly correlated. Mammography performed within 8 months of CT is unlikely to reveal cancer unless there is a suspicious clinical finding or a breast mass eccentric to the nipple. Men with clinical symptoms of gynecomastia do not need additional imaging with mammography to confirm the diagnosis if they have undergone recent cross-sectional imaging.

  8. Colour application on mammography image segmentation

    NASA Astrophysics Data System (ADS)

    Embong, R.; Aziz, N. M. Nik Ab.; Karim, A. H. Abd; Ibrahim, M. R.

    2017-09-01

    The segmentation process is one of the most important steps in image processing and computer vision since it is vital in the initial stage of image analysis. Segmentation of medical images involves complex structures and it requires precise segmentation result which is necessary for clinical diagnosis such as the detection of tumour, oedema, and necrotic tissues. Since mammography images are grayscale, researchers are looking at the effect of colour in the segmentation process of medical images. Colour is known to play a significant role in the perception of object boundaries in non-medical colour images. Processing colour images require handling more data, hence providing a richer description of objects in the scene. Colour images contain ten percent (10%) additional edge information as compared to their grayscale counterparts. Nevertheless, edge detection in colour image is more challenging than grayscale image as colour space is considered as a vector space. In this study, we implemented red, green, yellow, and blue colour maps to grayscale mammography images with the purpose of testing the effect of colours on the segmentation of abnormality regions in the mammography images. We applied the segmentation process using the Fuzzy C-means algorithm and evaluated the percentage of average relative error of area for each colour type. The results showed that all segmentation with the colour map can be done successfully even for blurred and noisy images. Also the size of the area of the abnormality region is reduced when compare to the segmentation area without the colour map. The green colour map segmentation produced the smallest percentage of average relative error (10.009%) while yellow colour map segmentation gave the largest percentage of relative error (11.367%).

  9. With the Advent of Tomosynthesis in the Workup of Mammographic Abnormality, is Spot Compression Mammography Now Obsolete? An Initial Clinical Experience.

    PubMed

    Ni Mhuircheartaigh, Neasa; Coffey, Louise; Fleming, Hannah; O' Doherty, Ann; McNally, Sorcha

    2017-09-01

    To determine if the routine use of spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and architectural distortion since the availability of digital breast tomosynthesis. We introduced breast tomosynthesis in the workup of screen detected abnormalities in our screening center in January 2015. During an initial learning period with tomosynthesis standard spot compression views were also performed. Three consultant breast radiologists retrospectively reviewed all screening mammograms recalled for assessment over the first 6-month period. We assessed retrospectively whether there was any additional diagnostic information obtained from spot compression views not already apparent on tomography. All cases were also reviewed for any additional lesions detected by tomosynthesis, not detected on routine 2-view screening mammography. 548 women screened with standard 2-view digital screening mammography were recalled for assessment in the selected period and a total of 565 lesions were assessed. 341 lesions were assessed by both tomosynthesis and routine spot compression mammography. The spot compression view was considered more helpful than tomosynthesis in only one patient. This was because the breast was inadequately positioned for tomosynthesis and the area in question was not adequately imaged. Apart from this technical error there was no asymmetry, distortion or mass where spot compression provided more diagnostic information than tomosynthesis alone. We detected three additional cancers on tomosynthesis, not detected by routine screening mammography. From our initial experience with tomosynthesis we conclude that spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and distortions where tomosynthesis is available. © 2017 Wiley Periodicals, Inc.

  10. Screening mammography among nursing home residents in the United States: Current guidelines and practice.

    PubMed

    Mack, Deborah S; Epstein, Mara M; Dubé, Catherine; Clark, Robin E; Lapane, Kate L

    2018-06-04

    United States (US) guidelines regarding when to stop routine breast cancer screening remain unclear. No national studies to-date have evaluated the use of screening mammography among US long-stay nursing home residents. This cross-sectional study was designed to identify prevalence, predictors, and geographic variation of screening mammography among that population in the context of current US guidelines. Screening mammography prevalence, identified with Physician/Supplier Part B claims and stratified by guideline age classification (65-74, ≥75 years), was estimated for all women aged ≥65 years residing in US Medicare- and Medicaid- certified nursing homes (≥1 year) with an annual Minimum Data Set (MDS) 3.0 assessment, continuous Medicare Part B enrollment, and no clinical indication for screening mammography as of 2011 (n = 389,821). The associations between resident- and regional- level factors, and screening mammography, were estimated by crude and adjusted prevalence ratios from robust Poisson regressions clustered by facility. Women on average were 85.4 (standard deviation ±8.1) years old, 77.9% were disabled, and 76.3% cognitively impaired. Screening mammography prevalence was 7.1% among those aged 65-74 years (95% Confidence Interval (CI): 6.8%-7.3%) and 1.7% among those ≥75 years (95% CI, 1.7%-1.8%), with geographic variation observed. Predictors of screening in both age groups included race, cognitive impairment, frailty, hospice, and some comorbidities. These results shed light on the current screening mammography practices in US nursing homes. Thoughtful consideration about individual screening recommendations and the implementation of more clear guidelines for this special population are warranted to prevent overscreening. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. The self-referred mammography patient: a new responsibility for radiologists.

    PubMed

    Monsees, B; Destouet, J M; Evens, R G

    1988-01-01

    A mammography screening program was initiated in which self-referred women were accepted for examination. Two views of each breast were obtained, and no physical examination was performed. Reports were sent to each patient and to the patient's primary care physician, if she had one. The program was successful in that the number of examinations performed per day increased from 36 to 80 within 6 months. Approximately 50% of the women who came for screening did so at their own request. Self-referred women with abnormal findings on mammograms who did not have a primary care physician were contacted by phone and told of the results. Advice was given for further evaluation, and the patient was referred to a local physician if she still did not know of one. Further workup in patients with abnormal findings was verified with the use of computer tracking and follow-up phone calls. Self-referral is an important component of screening mammography, but it places added responsibility on the radiologist in cases in which there is no referring physician.

  12. Mobile measurement setup according to IEC 62220-1-2 for DQE determination on digital mammography systems

    NASA Astrophysics Data System (ADS)

    Greiter, Matthias B.; Hoeschen, Christoph

    2010-04-01

    The international standard IEC 62220-1-2 defines the measurement procedure for determination of the detective quantum efficiency (DQE) of digital x-ray imaging devices used in mammography. A mobile setup complying to this standard and adaptable to most current systems was constructed in the Helmholtz Zentrum München to allow for an objective technical comparison of current full field digital mammography units employed in mammography screening in Germany. This article demonstrates the setup's capabilities with a focus on the measurement uncertainties of all quantities contributing to DQE measurements. Evaluation of uncertainties encompasses results from measurements on a Sectra Microdose Mammography in clinical use, as well as on a prototype of a Fujifilm Amulet system at various radiation qualities. Both systems have a high spatial resolution of 50 μm × 50 μm. The modulation transfer function (MTF), noise power spectrum (NPS) and DQE of the Sectra MDM are presented in comparison to results previously published by other authors.

  13. External validation of Medicare claims codes for digital mammography and computer-aided detection.

    PubMed

    Fenton, Joshua J; Zhu, Weiwei; Balch, Steven; Smith-Bindman, Rebecca; Lindfors, Karen K; Hubbard, Rebecca A

    2012-08-01

    While Medicare claims are a potential resource for clinical mammography research or quality monitoring, the validity of key data elements remains uncertain. Claims codes for digital mammography and computer-aided detection (CAD), for example, have not been validated against a credible external reference standard. We matched Medicare mammography claims for women who received bilateral mammograms from 2003 to 2006 to corresponding mammography data from the Breast Cancer Surveillance Consortium (BCSC) registries in four U.S. states (N = 253,727 mammograms received by 120,709 women). We assessed the accuracy of the claims-based classifications of bilateral mammograms as either digital versus film and CAD versus non-CAD relative to a reference standard derived from BCSC data. Claims data correctly classified the large majority of film and digital mammograms (97.2% and 97.3%, respectively), yielding excellent agreement beyond chance (κ = 0.90). Claims data correctly classified the large majority of CAD mammograms (96.6%) but a lower percentage of non-CAD mammograms (86.7%). Agreement beyond chance remained high for CAD classification (κ = 0.83). From 2003 to 2006, the predictive values of claims-based digital and CAD classifications increased as the sample prevalences of each technology increased. Medicare claims data can accurately distinguish film and digital bilateral mammograms and mammograms conducted with and without CAD. The validity of Medicare claims data regarding film versus digital mammography and CAD suggests that these data elements can be useful in research and quality improvement. ©2012 AACR.

  14. Participation rate or informed choice? Rethinking the European key performance indicators for mammography screening.

    PubMed

    Strech, Daniel

    2014-03-01

    Despite the intensive controversies about the likelihood of benefits and harms of mammography screening almost all experts conclude that the choice to screen or not to screen needs to be made by the individual patient who is adequately informed. However, the "European guideline for quality assurance in breast cancer screening and diagnosis" specifies a participation rate of 70% as the key performance indicator for mammography screening. This paper argues that neither the existing evidence on benefits and harms, nor survey research with women, nor compliance rates in clinical trials, nor cost-effectiveness ratios justify participation rates as a reasonable performance indicator for preference-sensitive condition such as mammography screening. In contrast, an informed choice rate would be more reasonable. Further research needs to address the practical challenges in assessing informed choice rates. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. ‘It’s Easier Said Than Done’: Perspectives on Mammography From Women With Intellectual Disabilities

    PubMed Central

    Wilkinson, Joanne E.; Deis, Cristina E.; Bowen, Deborah J.; Bokhour, Barbara G.

    2011-01-01

    PURPOSE Women with intellectual disabilities (or mental retardation) are living longer, receiving primary care in the community, and have equal rates of breast cancer compared with women in the general population, but they have lower rates of mammography. Although several public campaigns have successfully raised the mammography rate for racial and ethnic minority women, they have not penetrated the community of women with intellectual disabilities. No research to date has explored potential barriers to mammography for these women by involving the women themselves as participants. METHODS We undertook a qualitative study to explore the perceptions and understanding of mammography for women with intellectual disabilities and some of the potential reasons they would or would not have the test. Twenty-seven intellectually disabled women were recruited through a variety of community groups and interviewed using a semistructured interview guide. Data were analyzed using qualitative techniques from grounded theory. RESULTS Participants in this study described being poorly prepared for mammography: they did not understand its purpose and were not prepared for the logistics of the experience. The latter was more upsetting to participants and contributed to their negative perceptions of mammography. Participants reported feeling unprepared and singled out for being unprepared, despite their desire to have at least 1 mammogram, as do other women their age. CONCLUSIONS Women with intellectual disabilities perceive mammography differently than do women who do not have intellectual disabilities, and their perception is informed by inadequate knowledge, anxiety, and inadequate preparation. These themes should be considered when planning cancer prevention interventions with this population and when counseling individual women in the clinical setting. PMID:21403141

  16. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

    PubMed Central

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O’Connell, Avice M.; Conover, David L.

    2013-01-01

    This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of mean glandular dose to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 mGy to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9±4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4±6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum-minimum) of MGD from dedicated breast CT was

  17. Quantitative contrast-enhanced mammography for contrast medium kinetics studies

    NASA Astrophysics Data System (ADS)

    Arvanitis, C. D.; Speller, R.

    2009-10-01

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm-2 has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm-2 within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  18. Office Systems and Their Influence on Mammography Use in Rural and Urban Primary Care

    ERIC Educational Resources Information Center

    Engelman, Kimberly K.; Ellerbeck, Edward F.; Perpich, Denise; Nazir, Niaman; McCarter, Kevin; Ahluwalia, Jasjit S.

    2004-01-01

    Breast cancer screening rates are lower in rural communities. Although studies have addressed barriers to mammography for rural residents, physician practice barriers have received less attention. Purpose: Controlled clinical trials have shown that the use of office reminder systems in primary care practices is related to increased clinical care…

  19. Solid-state dosimeters: A new approach for mammography measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brateman, Libby F., E-mail: bratel@radiology.ufl.edu; Heintz, Philip H.

    2015-02-15

    Purpose: To compare responses of modern commercially available solid-state dosimeters (SStDs) used in mammography medical physics surveys for two major vendors of current digital mammography units. To compare differences in dose estimates among SStD responses with ionization chamber (IC) measurements for several target/filter (TF) combinations and report their characteristics. To review scientific bases for measurements of quantities required for mammography for traditional measurement procedures and SStDs. Methods: SStDs designed for use with modern digital mammography units were acquired for evaluation from four manufacturers. Each instrument was evaluated under similar conditions with the available mammography beams provided by two modern full-fieldmore » digital mammography units in clinical use: a GE Healthcare Senographe Essential (Essential) and a Hologic Selenia Dimensions 5000 (Dimensions), with TFs of Mo/Mo, Mo/Rh; and Rh/Rh and W/Rh, W/Ag, and W/Al, respectively. Measurements were compared among the instruments for the TFs over their respective clinical ranges of peak tube potentials for kVp and half-value layer (HVL) measurements. Comparisons for air kerma (AK) and their associated relative calculated average glandular doses (AGDs), i.e., using fixed mAs, were evaluated over the limited range of 28–30 kVp. Measurements were compared with reference IC measurements for AK, reference HVLs and calculated AGD, for two compression paddle heights for AK, to evaluate scatter effects from compression paddles. SStDs may require different positioning from current mammography measurement protocols. Results: Measurements of kVp were accurate in general for the SStDs (within −1.2 and +1.1 kVp) for all instruments over a wide range of set kVp’s and TFs and most accurate for Mo/Mo and W/Rh. Discrepancies between measurements and reference values were greater for HVL and AK. Measured HVL values differed from reference values by −6.5% to +3.5% depending on the

  20. Healthcare Use and Mammography Among Latinas With and Without Health Insurance Near the US-Mexico Border.

    PubMed

    Lapeyrouse, Lisa M; Miranda, Patricia Y; Morera, Osvaldo F; Heyman, Josiah McC; Balcazar, Hector G

    2017-04-01

    Among Latinas, lacking health insurance and having lower levels of acculturation are associated with disparities in mammography screening. We seek to investigate whether differences in lifetime mammography exist between Latina border residents by health insurance status and health care site (i.e., U.S. only or a combination of U.S. and Mexican health care). Using data from the 2009 to 2010 Ecological Household Study on Latino Border Residents, mammography screening was examined among (n = 304) Latinas >40 years old. While more acculturated women were significantly (p < .05) more likely to report ever having a mammogram than less acculturated women, ever having a mammogram was not predicted by health care site or insurance status. Latinas who utilize multiple systems of care have lower levels of acculturation and health insurance, thus representing an especially vulnerable population for experiencing disparities in mammography screening.

  1. Mammography screening services: market segments and messages.

    PubMed

    Scammon, D L; Smith, J A; Beard, T

    1991-01-01

    Mammography has become a vital tool for the early detection of breast cancer. Although many organizations and health care facilities are working to educate and motivate women to take advantage of the life saving opportunity that is offered through screening mammography, only twenty percent of women who should be screened actually have the procedure performed. In order to reach women who have not been screened, it is important to learn which factors most strongly motivate those women who do choose to have a mammogram. Depth interviews with 18 women attending a mobile mammography unit were conducted to explore the decision making process of women obtaining mammography screening services and to develop a profile of prevalent emotions, attitudes, and feelings associated with receiving breast cancer screening services. Analysis of the interview transcripts revealed several important themes to which health care professionals can direct marketing and health promotion strategies.

  2. Lack of nationwide Danish guidelines on mammography before non-oncological breast surgery.

    PubMed

    Foged, Thomas; Sørensen, Jens Ahm; Søe, Katrine Lydolph; Bille, Camilla

    2015-05-01

    Non-oncological breast surgery like breast reduction and mastopexy are often performed in younger patients, i.e. in women who have not yet had mammography. Breast cancer is, however, a very frequent disease that is increasingly prevalent in women below 50 years of age. Occult breast cancer may not be recognised before breast surgery, which may result in several disadvantages for the women. Therefore, detecting a breast cancer before a woman undergoes non-oncological breast surgery is of paramount importance. All public plastic surgery and breast surgery departments and all private clinics or hospitals providing plastic surgery were asked two questions: 1) When do you recommend a mammography prior to non-oncological breast surgery? 2) How old must a mammogram be before it needs to be repeated? Answers were received from all plastic surgery and breast surgery departments, and all but three of the private clinics and hospitals. Overall, information was obtained from 95.5% of the respondents (n = 63). Currently, there are no Danish guidelines on mammography before non-oncological breast surgery. A national guideline could recommend a preoperative mammogram from the age of 40 years stipulating that the mammogram should have been made within the past 12 months; however, the final recommendation should be prepared by a multidisciplinary working group counting experts from plastic surgery, breast surgery, pathology and radiology. not relevant. not relevant.

  3. The Impact of Medicaid Coverage and Reimbursement on Access to Diagnostic Mammography

    PubMed Central

    Schuur, Jeremiah D.; Shah, Akash; Wu, Zheyang; Forman, Howard P.; Gross, Cary P.

    2013-01-01

    BACKGROUND Women of low socioeconomic status are at risk for delayed evaluation of abnormal mammograms and later stage presentations of breast cancer. Medicaid reimbursement for clinical services is lower than Medicare reimbursement, yet it is unclear whether low Medicaid reimbursement is a barrier to accessing mammography. The objective of the current study was to determine the association between reported insurance type (Medicaid vs Medicare), Medicaid reimbursement rate, and access to diagnostic mammography (DM). METHODS Standardized patients (SPs) called 521 mammography facilities in defined geographic regions of 11 states in 2005. Facilities were divided between high, middle, and low reimbursing states based on the state’s relative Medicaid-to-Medicare reimbursement rate for DM. SPs contacted each facility twice to schedule a DM using the same clinical vignette but switching insurance status (Medicaid vs Medicare). The authors measured the proportion of SPs who were offered 1) any appointment and 2) a timely appointment, defined as a third available appointment within 20 business days. RESULTS SPs with Medicaid were less likely to receive an appointment than SPs with Medicare (91% vs 99.1%; difference, 8.1%; 95% confidence interval, 5.3%–10.9% [P < .001]). Among facilities that offered appointments to both callers, the proportion of timely appointments did not differ between Medicaid (93.7%) and Medicare (92.9%; P = .51). States’ Medicaid reimbursement rates for DM were not associated with the percentage of SPs with Medicaid who were offered any appointment (P = .50) or a timely appointment (P = .69). CONCLUSIONS Callers with Medicaid were offered appointments for DM less frequently than callers with Medicare, although both were widely accepted. State Medicaid reimbursement rates did not affect access to mammography. PMID:19728371

  4. Demographic factors influencing consensus opinion on the recall for women screened by mobile mammography unit in taiwan.

    PubMed

    Yu-Mei, Lee; Hsueh-Hua, Yao

    2013-09-01

    The incidence of breast cancer has had a four-fold increase from 1980 to 2005 in Taiwan. Limited data have been available on mobile breast screening in the Taiwanese population since 2009. This study aims at investigating the factors influencing consensus opinion on the recall for mobile breast screening in Taiwan. The factors were categorized by individual health background, socioeconomic status and knowledge about breast screening. There were 502 questionnaires collected from Taiwanese women examined on mobile mammography screening vehicle. Data were then analyzed by SPSS 12 via analysis of variance (ANOVA), F-test, t-test or chi-square test. Strong participation was associated with a younger age, higher educational level, higher incomes, previous history of cancer, previous family history of cancer, one or two prior mammographies, more correct recognitions of mammography, recall rate, and breast cancer risk. If the false-positive result occurred, 83.9%, 81.9% and 77.3% of the women agreed or strongly agreed to participate in noninvasive and invasive testing and screening mammography, respectively. The policy makers should notify the importance of demographic factors affecting further examination for early detection of breast cancer in Taiwan.

  5. [False positive result in mammography and its association with the presence of obesity: a case-control study].

    PubMed

    Castro-Ibarra, Marisela; Menchaca-Díaz, Rufino; Cabrales-Ruvalcaba, J Jesús; Luna-V Gómez, Rosa Alicia

    2016-01-01

    To analyze the association between a false positive result in mammography and obesity, inside the breast cancer early detection program in women affiliated to the Institute of Security and Social Services for Government and Municipality workers of the State of Baja California (ISSSTECALI). A case-control, retrospective study was done in women affiliated to ISSSTECALI to whom a mammography was performed between 2009 and 2012. Women with a false positive result in mammography were included as cases. Controls were women with a true negative result in mammography. Three controls were randomly selected for each case. Obesity was established with the body mass index (BMI) consigned in the woman's clinical file. Age and estrogen replacement therapy were included as co-variables. Seventy nine cases were identified and 237 controls were included. Obesity was observed in 54.4% of cases and in 41.3% of controls (odds ratio: 1.69; 95% confidence interval for odds ratio: 1.01-2.82; p value: 0.043). A logistic regression model including covariables maintained the observed association (p = 0.044). No association was found with analyzed co-variables. A false positive result in mammography was associated with the presence of obesity.

  6. Beliefs of Turkish female teaching staff regarding mammography scanning.

    PubMed

    Temel, Ayla Bayik; Ardahan, Melek; Sesli, Esra

    2010-01-01

    To our knowledge, there has hitherto been no research to determine the beliefs of female teaching staff, who are highly educated and form a special risk group regarding breast cancer, towards mammography scanning in Turkey. Definitive research was planned to determine the beliefs of the female teaching staff working in a university. Data were collected by researchers via face-to-face interview using a sociodemographic questionnaire and " Health Belief Model ". The point average of the teaching staff in the mammography benefits sub-scale is 19.6 ± 3.87, their average item score is 3.91. The point average of the teaching staff in the mammography obstacles sub-scale is 21.17 ± 6.87, their average item score is 1.92. They agree on the benefits of the mammography, but they do not agree on the obstacles to mammography.

  7. Prospective study aiming to compare 2D mammography and tomosynthesis + synthesized mammography in terms of cancer detection and recall. From double reading of 2D mammography to single reading of tomosynthesis.

    PubMed

    Romero Martín, Sara; Raya Povedano, Jose Luis; Cara García, María; Santos Romero, Ana Luz; Pedrosa Garriguet, Margarita; Álvarez Benito, Marina

    2018-06-01

    To evaluate tomosynthesis compared with 2D-mammography in cancer detection and recalls in a screening-programme, and assess performing synthesized instead of 2D, and compare double reading of 2D with single reading of tomosynthesis. Women (age 50-69 years) participating in the screening-programme were included. 2D-mammography and tomosynthesis were performed. There were four reading models: 2D-mammography (first); 2D-mammography (second); tomosynthesis + synthesized (third); tomosynthesis + synthesized + 2D (fourth reading). Paired double reading of 2D (first+second) and tomosynthesis (third+fourth) were analysed. In 16,067 participants, there were 98 cancers and 1,196 recalls. Comparing double reading of 2D with single reading of tomosynthesis, there was an increase of 12.6 % in cancer detection with the third reading (p= 0.043) and 6.9 % with the fourth reading (p=0.210), and a decrease in recalls of 40.5 % (p<0.001) and 44.4 % (p<0.001), respectively. With double reading of both techniques, there was an increase in cancer detection of 17.4 % (p = 0.004) and a decrease in recalls of 12.5 % (p = 0.001) with tomosynthesis. Single reading of tomosynthesis plus synthesized increased cancer detection and decreased recalls compared with double reading 2D. 2D did not improve results when added to tomosynthesis. • Tomosynthesis increases cancer detection and decreases recall rates versus 2D mammography. • Synthesized-mammography avoids performing 2D, showing higher cancer detection. • Single reading of tomosynthesis + synthesized is feasible as a new practice.

  8. Variation in false-positive rates of mammography reading among 1067 radiologists: a population-based assessment.

    PubMed

    Tan, Alai; Freeman, Daniel H; Goodwin, James S; Freeman, Jean L

    2006-12-01

    The accuracy of mammography reading varies among radiologists. We conducted a population-based assessment on radiologist variation in false- positive rates of screening mammography and its associated radiologist characteristics. About 27,394 screening mammograms interpreted by 1067 radiologists were identified from a 5% non-cancer sample of Medicare claims during 1998-1999. The data were linked to the American Medical Association Masterfile to obtain radiologist characteristics. Multilevel logistic regression models were used to examine the radiologist variation in false-positive rates of screening mammography and the associated radiologist characteristics. Radiologists varied substantially in the false-positive rates of screening mammography (ranging from 1.5 to 24.1%, adjusting for patient characteristics). A longer time period since graduation is associated with lower false-positive rates (odds ratio [OR] for every 10 years increase: 0.87, 95% Confidence Interval [CI], 0.81-0.94) and female radiologists had higher false-positive rates than male radiologists (OR = 1.25, 95% CI, 1.05-1.49), adjusting for patient and other radiologist characteristics. The unmeasured factors contributed to about 90% of the between-radiologist variance. Radiologists varied greatly in accuracy of mammography reading. Female and more recently trained radiologists had higher false-positive rates. The variation among radiologists was largely due to unmeasured factors, especially unmeasured radiologist factors. If our results are confirmed in further studies, they suggest that system-level interventions would be required to reduce variation in mammography interpretation.

  9. Using automatically extracted information from mammography reports for decision-support

    PubMed Central

    Bozkurt, Selen; Gimenez, Francisco; Burnside, Elizabeth S.; Gulkesen, Kemal H.; Rubin, Daniel L.

    2016-01-01

    Objective To evaluate a system we developed that connects natural language processing (NLP) for information extraction from narrative text mammography reports with a Bayesian network for decision-support about breast cancer diagnosis. The ultimate goal of this system is to provide decision support as part of the workflow of producing the radiology report. Materials and methods We built a system that uses an NLP information extraction system (which extract BI-RADS descriptors and clinical information from mammography reports) to provide the necessary inputs to a Bayesian network (BN) decision support system (DSS) that estimates lesion malignancy from BI-RADS descriptors. We used this integrated system to predict diagnosis of breast cancer from radiology text reports and evaluated it with a reference standard of 300 mammography reports. We collected two different outputs from the DSS: (1) the probability of malignancy and (2) the BI-RADS final assessment category. Since NLP may produce imperfect inputs to the DSS, we compared the difference between using perfect (“reference standard”) structured inputs to the DSS (“RS-DSS”) vs NLP-derived inputs (“NLP-DSS”) on the output of the DSS using the concordance correlation coefficient. We measured the classification accuracy of the BI-RADS final assessment category when using NLP-DSS, compared with the ground truth category established by the radiologist. Results The NLP-DSS and RS-DSS had closely matched probabilities, with a mean paired difference of 0.004 ± 0.025. The concordance correlation of these paired measures was 0.95. The accuracy of the NLP-DSS to predict the correct BI-RADS final assessment category was 97.58%. Conclusion The accuracy of the information extracted from mammography reports using the NLP system was sufficient to provide accurate DSS results. We believe our system could ultimately reduce the variation in practice in mammography related to assessment of malignant lesions and improve

  10. Mammography usage with relevant factors among women with mental disabilities in Taiwan: a nationwide population-based study.

    PubMed

    Yen, Suh-May; Kung, Pei-Tseng; Tsai, Wen-Chen

    2015-02-01

    Women with mental illness are at increased risk of developing and dying from breast cancer and are thus in urgent need of breast cancer preventive care. This study examined the use of screening mammography by Taiwanese women with mental disabilities and analyzed factors affecting this use. 17,243 Taiwanese women with mental disabilities aged 50-69 years were retrospectively included as study subjects. Linked patient data were obtained from three national databases in Taiwan (the 2008 database of physically and mentally disabled persons, the Health Promotion Administration's 2007-2008 mammography screening data, and claims data from the National Health Insurance Research Database). Besides descriptive statistics and bivariate analysis, logistic regression analysis was also performed to examine factors affecting screening mammography use. The 2007-2008 mammography screening rate for Taiwanese women with mental disabilities was 8.79% (n=1515). Variables that significantly influenced screening use were income, education, presence of catastrophic illness/injury, severity of mental disability, and usage of other preventive care services. Screening was positively correlated with income and education. Those with catastrophic illness/injury were more likely to be screened (odds ratio [OR], 1.40; 95% CI=1.15-1.72). Severity of disability was negatively correlated with screening, with very severe, severe, and moderate disability being associated with 0.34-0.69 times the odds of screening as mild disability. In Taiwan, women with mental disabilities receive far less mammography screening than women in general. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Barriers to Mammography among Inadequately Screened Women

    ERIC Educational Resources Information Center

    Stoll, Carolyn R. T.; Roberts, Summer; Cheng, Meng-Ru; Crayton, Eloise V.; Jackson, Sherrill; Politi, Mary C.

    2015-01-01

    Mammography use has increased over the past 20 years, yet more than 30% of women remain inadequately screened. Structural barriers can deter individuals from screening, however, cognitive, emotional, and communication barriers may also prevent mammography use. This study sought to identify the impact of number and type of barriers on mammography…

  12. Mammography screening: A major issue in medicine.

    PubMed

    Autier, Philippe; Boniol, Mathieu

    2018-02-01

    -detected cancers. Overdiagnosis leads to overtreatment and inflicts considerable physical, psychological and economic harm on many women. Overdiagnosis has also exerted considerable disruptive effects on the interpretation of clinical outcomes expressed in percentages (instead of rates) or as overall survival (instead of mortality rates or stage-specific survival). Rates of radical mastectomies have not decreased following the introduction of screening and keep rising in some countries (e.g. the United States of America (USA)). Hence, the epidemiological picture of mammography screening closely resembles that of screening for neuroblastoma. Reappraisals of Swedish mammography trials demonstrate that the design and statistical analysis of these trials were different from those of all trials on screening for cancers other than breast cancer. We found compelling indications that these trials overestimated reductions in breast cancer mortality associated with screening, in part because of the statistical analyses themselves, in part because of improved therapies and underreporting of breast cancer as the underlying cause of death in screening groups. In this regard, Swedish trials should publish the stage-specific breast cancer mortality rates for the screening and control groups separately. Results of the Greater New York Health Insurance Plan trial are biased because of the underreporting of breast cancer cases and deaths that occurred in women who did not participate in screening. After 17 years of follow-up, the United Kingdom (UK) Age Trial showed no benefit from mammography screening starting at age 39-41. Until around 2005, most proponents of breast screening backed the monitoring of changes in advanced cancer incidence and comparative studies on breast cancer mortality for the evaluation of breast screening effectiveness. However, in an attempt to mitigate the contradictions between results of mammography trials and population data, breast-screening proponents have elected to

  13. Do physician communication skills influence screening mammography utilization?

    PubMed

    Meguerditchian, Ari-Nareg; Dauphinee, Dale; Girard, Nadyne; Eguale, Tewodros; Riedel, Kristen; Jacques, André; Meterissian, Sarkis; Buckeridge, David L; Abrahamowicz, Michal; Tamblyn, Robyn

    2012-07-25

    The quality of physician communication skills influences health-related decisions, including use of cancer screening tests. We assessed whether patient-physician communication examination scores in a national, standardized clinical skills examination predicted future use of screening mammography (SM). Cohort study of 413 physicians taking the Medical Council of Canada clinical skills examination between 1993 and 1996, with follow up until 2006. Administrative claims for SM performed within 12 months of a comprehensive health maintenance visit for women 50-69 years old were reviewed. Multivariable regression was used to estimate the relationship between physician communication skills exam score and patients' SM use while controlling for other factors. Overall, 33.8 % of 96,708 eligible women who visited study physicians between 1993 and 2006 had an SM in the 12 months following an index visit. Patient-related factors associated with increased SM use included higher income, non-urban residence, low Charlson co-morbidity index, prior benign breast biopsy and an interval >12 months since the previous mammogram. Physician-related factors associated with increased use of SM included female sex, surgical specialty, and higher communication skills score. After adjusting for physician and patient-related factors, the odds of SM increased by 24 % for 2SD increase in communication score (OR: 1.24, 95 % CI: 1.11 - 1.38). This impact was even greater in urban areas (OR 1.30, 95 % CI: 1.16, 1.46) and did not vary with practice experience (interaction p-value 0.74). Physicians with better communication skills documented by a standardized licensing examination were more successful at obtaining SM for their patients.

  14. [Digital breast tomosynthesis : technical principles, current clinical relevance and future perspectives].

    PubMed

    Hellerhoff, K

    2010-11-01

    In recent years digital full field mammography has increasingly replaced conventional film mammography. High quality imaging is guaranteed by high quantum efficiency and very good contrast resolution with optimized dosing even for women with dense glandular tissue. However, digital mammography remains a projection procedure by which overlapping tissue limits the detectability of subtle alterations. Tomosynthesis is a procedure developed from digital mammography for slice examination of breasts which eliminates the effects of overlapping tissue and allows 3D imaging of breasts. A curved movement of the X-ray tube during scanning allows the acquisition of many 2D images from different angles. Subseqently, reconstruction algorithms employing a shift and add method improve the recognition of details at a defined level and at the same time eliminate smear artefacts due to overlapping structures. The total dose corresponds to that of conventional mammography imaging. The technical procedure, including the number of levels, suitable anodes/filter combinations, angle regions of images and selection of reconstruction algorithms, is presently undergoing optimization. Previous studies on the clinical value of tomosynthesis have examined screening parameters, such as recall rate and detection rate as well as information on tumor extent for histologically proven breast tumors. More advanced techniques, such as contrast medium-enhanced tomosynthesis, are presently under development and dual-energy imaging is of particular importance.

  15. Mammography screening among Arab American women in metropolitan Detroit.

    PubMed

    Schwartz, Kendra; Fakhouri, Monty; Bartoces, Monina; Monsur, Joseph; Younis, Amani

    2008-12-01

    Mammography screening behavior has not been well studied among Middle Eastern immigrant women. We conducted a telephone survey of 365 Arab American women residing in metropolitan Detroit, home to one of the largest populations of Middle Eastern immigrants in the US, to determine prevalence of factors associated with mammography, and attitudes and beliefs regarding mammography screening. Of 365 participants, only five were born in the US. Mean age was 53.2 years (SD 10.8). Two hundred twelve (58.1%) reported having mammogram every 1-2 years; 70% ever had mammogram. Age 50-64 years, having health insurance, married status, being in the US over 10 years, and being Lebanese were associated with mammography every 1-2 years. After adjusting for demographic factors, perceived seriousness of disease, general health motivation, and having fewer barriers were associated with more frequent screening. Appropriate mammography screening is decreased in this group. Targeted outreach regarding screening is appropriate for this population; however, lack of insurance may prevent adequate follow-up.

  16. Diagnostic performance of dual-energy contrast-enhanced subtracted mammography in dense breasts compared to mammography alone: interobserver blind-reading analysis.

    PubMed

    Cheung, Yun-Chung; Lin, Yu-Ching; Wan, Yung-Liang; Yeow, Kee-Min; Huang, Pei-Chin; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chang, Chee-Jen

    2014-10-01

    To analyse the accuracy of dual-energy contrast-enhanced spectral mammography in dense breasts in comparison with contrast-enhanced subtracted mammography (CESM) and conventional mammography (Mx). CESM cases of dense breasts with histological proof were evaluated in the present study. Four radiologists with varying experience in mammography interpretation blindly read Mx first, followed by CESM. The diagnostic profiles, consistency and learning curve were analysed statistically. One hundred lesions (28 benign and 72 breast malignancies) in 89 females were analysed. Use of CESM improved the cancer diagnosis by 21.2 % in sensitivity (71.5 % to 92.7 %), by 16.1 % in specificity (51.8 % to 67.9 %) and by 19.8 % in accuracy (65.9 % to 85.8 %) compared with Mx. The interobserver diagnostic consistency was markedly higher using CESM than using Mx alone (0.6235 vs. 0.3869 using the kappa ratio). The probability of a correct prediction was elevated from 80 % to 90 % after 75 consecutive case readings. CESM provided additional information with consistent improvement of the cancer diagnosis in dense breasts compared to Mx alone. The prediction of the diagnosis could be improved by the interpretation of a significant number of cases in the presence of 6 % benign contrast enhancement in this study. • DE-CESM improves the cancer diagnosis in dense breasts compared with mammography. • DE-CESM shows greater consistency than mammography alone by interobserver blind reading. • Diagnostic improvement of DE-CESM is independent of the mammographic reading experience.

  17. Correlates of mammography utilization among working Muslim Iranian women.

    PubMed

    Hatefnia, Effat; Niknami, Shamsaddin; Bazargan, Mohsen; Mahmoodi, Mahmood; Lamyianm, Minoor; Alavi, Nasrien

    2010-06-01

    Most countries in Middle East have been successful in establishing and furthering basic facilities for screening, diagnosis, and treatment of breast cancer. The rate of compliance with mammography screening, however, remains well below North American and Western European countries. We utilized the Health Belief Model (HBM) to explore factors associated with mammography screening behavior among a sample of 320 Muslim women aged > or = 35. Carrying out this cross-sectional study, we found that screening behavior was associated with older age, higher perceived benefit of breast cancer screening, and lower perceived barrier. Additionally, we demonstrate the importance of religious beliefs in influencing mammography screening behavior and explaining the link between religious involvement and mammography behavior.

  18. Influence of advertisement on women's attitudes toward mammography screening.

    PubMed

    Collins, C; Davis, L S; Rentz, K; Vannoy, D

    1997-01-01

    This project represents an effort to incorporate a feminist perspective into research on mammography screening. The purpose of this study was to assess women's attitudes toward four advertisements designed to encourage mammography screening. The goal was to create awareness about women's attitudes toward mammography advertisements in order to encourage the development of more effective and responsive motivational materials. The results indicated that each ad communicated different messages about the seriousness of breast cancer and the efficacy of mammography in detecting early breast cancer. Each ad also affected women differently regarding their feelings of control over breast cancer, their perceived loss of sex appeal resulting from a breast cancer diagnosis, and their general fear of breast cancer.

  19. The Correlation between the Scores of Written Examination, the Clinical Clerkship Examination, the Clinical Skill Assessment, and the Graduation Examination of the Medical Students.

    PubMed

    Koh, Suk Bong; Park, Hye Jin

    2009-12-01

    The aim of this study was to investigate correlations between medical student scores on 4 examinations: the written examination, clinical clerkship examination, clinical skill assessment, and graduation examination. Scores for 51 students who entered Daegu Catholic Medical School in 2005 on the written examination, clinical clerkship examination, clinical skill assessment, and graduation examination were included. Correlations between the scores were analyzed statistically. The scores on the written examination showed a strong correlation with those of the clinical clerkship assessment (0.833) and graduation examination (0.821). The clinical clerkship assessment scores correlated significantly with graduation examination scores (0.907). In addition, clinical skill assessment scores correlated with the written examination (0.579), clinical clerkship examination (0.570), and graduation examination (0.465) scores. Overall, the correlation between the scores on the clinical clerkship examination and the written examination was more significant than the correlation between scores on the clinical clerkship examination and clinical skill assessment. Therefore, we need to improve the evaluation method for the clinical clerkship examination and clinical skill assessment.

  20. Effect of age on breast cancer screening using tomosynthesis in combination with digital mammography.

    PubMed

    Rafferty, Elizabeth A; Rose, Stephen L; Miller, Dave P; Durand, Melissa A; Conant, Emily F; Copit, Debra S; Friedewald, Sarah M; Plecha, Donna M; Ott, Ingrid L; Hayes, Mary K; Carlson, Kara L; Cink, Thomas M; Barke, Lora D; Greer, Linda N; Niklason, Loren T

    2017-08-01

    To determine the effect of tomosynthesis imaging as a function of age for breast cancer screening. Screening performance metrics from 13 institutions were examined for 12 months prior to introduction of tomosynthesis (period 1) and compared to those after introduction of tomosynthesis (period 2, range 3-22 months). Screening metrics for women ages 40-49, 50-59, 60-69, and 70+ , included rates per 1000 screens for recalls, biopsies, cancers, and invasive cancers detected. Performance parameters were compared for women screened with digital mammography alone (n = 278,908) and digital mammography + tomosynthesis (n = 173,414). Addition of tomosynthesis to digital mammography produced significant reductions in recall rates for all age groups and significant increases in cancer detection rates for women 40-69. Largest recall rate reduction with tomosynthesis was for women 40-49, decreasing from 137 (95% CI 117-156) to 115 (95% CI 95-135); difference, -22 (95% CI -26 to -18; P < .001). Simultaneous increase in invasive cancer detection rate for women 40-49 from 1.6 (95% CI 1.2-1.9) to 2.7 (95% CI 2.2-3.1) with tomosynthesis (difference, 1.1; 95% CI 0.6-1.6; P < .001) was observed. Addition of tomosynthesis to digital mammography increased invasive cancer detection rates for women 40-69 and decreased recall rates for all age groups with largest performance gains seen in women 40-49. The similar performance seen with tomosynthesis screening for women in their 40s compared to digital mammography for women in their 50s argues strongly for commencement of mammography screening at age 40 using tomosynthesis.

  1. A cost-effectiveness comparison of three tailored interventions to increase mammography screening.

    PubMed

    Saywell, Robert M; Champion, Victoria L; Skinner, Celette Sugg; Menon, Usha; Daggy, Joanne

    2004-10-01

    Mammography is the primary method used for breast cancer screening. However, adherence to recommended screening practices is still below acceptable levels. This study examined the cost-effectiveness of three combinations of tailored telephone and mailed intervention strategies for increasing adherence to mammography. There were 1044 participants who were randomly assigned to one of four groups. A logistic regression model with adherence as the dependent variable and group as the independent variable was used to test for significant differences, and a ratio of cost/improvement in mammogram adherence evaluated the cost-effectiveness. All three of the interventions (tailored telephone, tailored mail, and tailored telephone and mail) had significantly better adherence rates compared with the control group (usual care). However, when also considering costs, one emerged as the superior strategy. The cost-effectiveness ratios for the three interventions show that the tailored mail (letter) was the most cost-effective strategy, achieving 43.3% mammography adherence at a marginal cost of dollar 0.39 per 1% increase in women screened. The tailored mail plus telephone achieved greater adherence (49.4%), but at a higher cost (dollar 0.56 per 1% increase in women screened). A tailored mail reminder is an effective and economical intervention to increase mammography adherence. Future research should confirm this finding and address its applicability to practice in other settings.

  2. A Reconstruction Algorithm for Breast Cancer Imaging With Electrical Impedance Tomography in Mammography Geometry

    PubMed Central

    Kao, Tzu-Jen; Isaacson, David; Saulnier, Gary J.; Newell, Jonathan C.

    2009-01-01

    The conductivity and permittivity of breast tumors are known to differ significantly from those of normal breast tissues, and electrical impedance tomography (EIT) is being studied as a modality for breast cancer imaging to exploit these differences. At present, X-ray mammography is the primary standard imaging modality used for breast cancer screening in clinical practice, so it is desirable to study EIT in the geometry of mammography. This paper presents a forward model of a simplified mammography geometry and a reconstruction algorithm for breast tumor imaging using EIT techniques. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and is validated by experiment using a phantom tank. A reconstruction algorithm for breast tumor imaging based on a linearization approach and the proposed forward model is presented. It is found that the proposed reconstruction algorithm performs well in the phantom experiment, and that the locations of a 5-mm-cube metal target and a 6-mm-cube agar target could be recovered at a target depth of 15 mm using a 32 electrode system. PMID:17405377

  3. A national cross-sectional study of adherence to timely mammography use in Malta.

    PubMed

    Marmarà, Danika; Marmarà, Vincent; Hubbard, Gill

    2018-03-27

    Routine mammography improves survival. To achieve health benefits, women must attend breast screening regularly at recommended time intervals. Maltese women are routinely invited to undergo mammography at three-year intervals at an organized breast screening programme (MBSP) or can opt to attend a private clinic. Previous research shows that health beliefs, particularly perceived barriers, were the most significant predictors of uptake to the first MBSP invitation. Whether these beliefs and other factors are predictive of adherence with recommended time intervals for mammography at organized or private screening in Malta is unknown. For the first time, this paper explores the predictors for Maltese women screened within or exceeding the recommended three-year frequency in organized or private screening in Malta. Information was obtained from a cross-sectional survey of 404 women, aged 50 to 60 years at the time of their first MBSP invitation, where women's characteristics, knowledge, health beliefs and illness perceptions were compared. The main variable of interest was women's mammography attendance within a three-year interval (ADHERENT) or exceeding three years (NON-ADHERENT). Data were analysed using descriptive statistics, chi-square test, Mann Whitney test, Independent Samples t-test and Shapiro Wilk test. At the time of the survey, 80.2% (n = 324) had been screened within three years (ADHERENT), 5.9% (n = 24) had exceeded the three-year frequency (NON-ADHERENT) while 13.9% (n = 56) never had a mammogram. No significant associations were found between ADHERENT or NON-ADHERENT women in relation to sociodemographic or health status variables (p > 0.05). Knowledge of screening frequency was significantly associated with women's mammography adherence (χ2 = 5.5, p = 0.020). Health beliefs were the strongest significant predictors to describe the variance between ADHERENT and NON-ADHERENT screeners. When Mann Whitney test and Independent

  4. Diagnostic criteria for mass lesions differentiating in electrical impedance mammography

    NASA Astrophysics Data System (ADS)

    A, Karpov; M, Korotkova

    2013-04-01

    The purpose of this research was to determine the diagnostic criteria for differentiating volumetric lesions in the mammary gland in electrical impedance mammography. The research was carried out utilizing the electrical impedance computer mammograph llMEIK v.5.6gg®, which enables to acquire images of 3-D conductivity distribution layers within mamma's tissues up to 5 cm depth. The weighted reciprocal projection method was employed to reconstruct the 3-D electric conductivity distribution of the examined organ. The results of 3,710 electrical impedance examinations were analyzed. The analysis of a volumetric lesion included assessment of its shape, contour, internal electrical structure and changes of the surrounding tissues. Moreover, mammary gland status was evaluated with the help of comparative and age-related electrical conductivity curves. The diagnostic chart is provided. Each criterion is measured in points. Using the numerical score for evaluation of mass and non-volumetric lesions within the mammary gland in electrical impedance mammography allowed comparing this information to BI-RADS categories developed by American College of Radiology experts. The article is illustrated with electrical impedance mammograms and tables.

  5. Is Mammography Useful in Older Women

    DTIC Science & Technology

    1999-06-01

    mammography in women age 70 and older . Using the Linked Medicare-SEER Tumor Registry Database, created by the National Cancer Institute and the Health Care... Health Interview Survey) have documented that mammography use decreases with advancing age (11,21,22). In 1993, only 25% of women age 65 and older ...related health services research. The linked database contains cancer information on patients 65 years of age and older from NCI’s SEER Program and

  6. The use of ultrasonography and digital mammography in women under 40 years with symptomatic breast cancer: a 7-year Irish experience.

    PubMed

    Redmond, C E; Healy, G M; Murphy, C F; O'Doherty, A; Foster, A

    2017-02-01

    Breast cancer in women under 40 years of age is rare and typically presents symptomatically. The optimal imaging modality for this patient group is controversial. Most women undergo ultrasonography with/without mammography. Young women typically have dense breasts, which can obscure the features of malignancy on film mammography, however, initial studies have suggested that digital mammography may have a more accurate diagnostic performance in younger women. Ultrasound generally performs well in this age group, although it is poor at detecting carcinoma in situ (DCIS). To evaluate the comparative diagnostic performance of ultrasonography and digital mammography in the initial diagnostic evaluation of women under 40 years of age with symptomatic breast cancer. Retrospective review of all women under the age of 40 years managed at our symptomatic breast cancer unit from January 2009 to December 2015. There were 120 patients that met the inclusion criteria for this study. The sensitivity of ultrasonography and digital mammography for breast cancer in this patient group was 95.8 and 87.5 %, respectively. The patients with a false negative mammographic examination were more likely to have dense breasts (p < 0.01). Five patients had a false negative ultrasonographic examination, withal of whom were diagnosed with DCIS detected by mammography. This study demonstrates the superior sensitivity of ultrasound for breast cancer in women under the age of 40 years, however, the results show that digital mammography has an important complimentary role in the comprehensive assessment of these patients, particularly in the diagnosis of DCIS.

  7. Understanding women's mammography intentions: a theory-based investigation.

    PubMed

    Naito, Mikako; O'Callaghan, Frances V; Morrissey, Shirley

    2009-01-01

    The present study compared the utility of two models (the Theory of Planned Behavior and Protection Motivation Theory) in identifying factors associated with intentions to undertake screening mammography, before and after an intervention. The comparison was made between the unique components of the two models. The effect of including implementation intentions was also investigated. Two hundred and fifty-one women aged 37 to 69 years completed questionnaires at baseline and following the delivery of a standard (control) or a protection motivation theory-based informational intervention. Hierarchical multiple regressions indicated that theory of planned behavior variables were associated with mammography intentions. Results also showed that inclusion of implementation intention in the model significantly increased the association with mammography intentions. The findings suggest that future interventions aiming to increase screening mammography participation should focus on the theory of planned behavior variables and that implementation intention should also be targeted.

  8. Non-attendance in mammography screening and women's social network: a cohort study on the influence of family composition, social support, attitudes and cancer in close relations.

    PubMed

    Manjer, Åsa Ritenius; Emilsson, Ulla Melin; Zackrisson, Sophia

    2015-06-28

    Mammography screening can reduce breast cancer mortality. The aim of the present study was to investigate non-attendance in mammography screening in relation to different aspects of a women's social network, attitudes and cancer in close relations. Data from the Malmö Diet and Cancer Study baseline examination in 1991-1996 was used. A re-examination began in 2007, and 1452 women participated. Family composition, social support, sense of belonging, attitudes on screening and breast cancer risk and on previous cancer in close relations were investigated in relation to self-reported participation in mammography screening using logistic regression analysis, yielding odds ratios with 95 % confidence intervals. Both attendees (98.0 %) and non-attendees (95.2 %) considered mammography screening important. Non-attendance in mammography screening was associated with being unmarried vs. married (2.40:1.30-4.45) and with not having vs. having children (1.77:1.08-2.92). Non-attendees planned to abstain from mammography screening in the future more often than attendees (4.78:2.56-8.90), and they had often abstained from cervical cancer screening (1.69:1.04-2.75). No other statistically significant association was found. This study indicates that family composition, but not necessarily the presence or absence of social support, perceived cancer risk or cancer in close relations, may affect non-attendance in mammography screening. A positive attitude towards mammography screening was found among both attendees and non-attendees, although the latter group planned to a lesser degree to attend mammography screening in the future.

  9. WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gingold, E; Karellas, A; Strauss, K

    Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years hasmore » changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice

  10. Radiation-Induced Breast Cancer Incidence and Mortality from Digital Mammography Screening: A Modeling Study

    PubMed Central

    Miglioretti, Diana L.; Lange, Jane; van den Broek, Jeroen J.; Lee, Christoph I.; van Ravesteyn, Nicolien T.; Ritley, Dominique; Kerlikowske, Karla; Fenton, Joshua J.; Melnikow, Joy; de Koning, Harry J.; Hubbard, Rebecca A.

    2016-01-01

    Background Estimates of radiation-induced breast cancer risk from mammography screening have not previously considered dose exposure variation or diagnostic work-up after abnormal screening. Objective To estimate distributions of radiation-induced breast cancer incidence and mortality from digital mammography screening, considering exposure from screening and diagnostic mammography and dose variation across women. Design Two simulation-modeling approaches using common data on screening mammography from the Breast Cancer Surveillance Consortium and radiation dose from mammography from the Digital Mammographic Imaging Screening Trial. Setting U.S. population. Patients Women aged 40–74 years. Interventions Annual or biennial digital mammography screening from age 40, 45, or 50 until 74. Measurements Lifetime breast cancer deaths averted (benefits) and radiation-induced breast cancer incidence and mortality per 100,000 women screened (harms). Results On average, annual screening of 100,000 women aged 40 to 74 years was projected to induce 125 breast cancers (95% confidence interval [CI]=88–178) leading to 16 deaths (95% CI=11–23) relative to 968 breast cancer deaths averted by early detection from screening. Women exposed at the 95th percentile were projected to develop 246 radiation-induced breast cancers leading to 32 deaths per 100,000 women. Women with large breasts requiring extra views for complete breast examination (8% of population) were projected to have higher radiation-induced breast cancer incidence and mortality (266 cancers, 35 deaths per 100,000 women), compared to women with small or average breasts (113 cancers, 15 deaths per 100,000 women). Biennial screening starting at age 50 reduced risk of radiation-induced cancers 5-fold. Limitations We were unable to estimate years of life lost from radiation-induced breast cancer. Conclusions Radiation-induced breast cancer incidence and mortality from digital mammography screening are impacted by dose

  11. Improvement in diagnostic performance of breast cancer: comparison between conventional digital mammography alone and conventional mammography plus digital breast tomosynthesis.

    PubMed

    Ohashi, Ryoko; Nagao, Michinobu; Nakamura, Izumi; Okamoto, Takahiro; Sakai, Shuji

    2018-04-12

    The aim of this study was to determine if the diagnostic performance of breast lesion examinations could be improved using both digital breast tomosynthesis (DBT) and conventional digital mammography (CDM). Our institutional review board approved the protocol, and patients were provided the opportunity to opt out of the study. A total of 628 patients aged 22-91 years with abnormal screening results or clinical symptoms were consecutively enrolled between June 2015 and March 2016. All patients underwent DBT and CDM, and 1164 breasts were retrospectively analyzed by three radiologists who interpreted the results based on the Breast Imaging Reporting and Data System. Categories 4 and 5 were considered positive, and pathological results were the gold standard. The diagnostic performance of CDM and CDM plus DBT was compared using the mean areas under the receiver operating characteristic (ROC) curves. A total of 100 breast cancer cases were identified. The areas under the ROC curves were 0.9160 (95% confidence interval 0.8779-0.9541) for CDM alone and 0.9376 (95% confidence interval 0.9019-0.9733) for CDM plus DBT. The cut-off values for both CDM alone and CDM plus DBT measurements were 4, with sensitivities of 61.0% (61/100) and 83.0% (83/100), respectively, and specificities of 99.1% (1054/1064) and 98.9% (1052/1064), respectively. CDM yielded 39 false-negative diagnoses, while CDM plus DBT identified breast cancer in 22 of those cases (56.4%). The combination of DBT and CDM for the diagnosis of breast cancer in women with abnormal examination findings or clinical symptoms proved effective and should be used to improve the diagnostic performance of breast cancer examinations.

  12. A brief nursing intervention reduces anxiety before breast cancer screening mammography.

    PubMed

    Fernández-Feito, Ana; Lana, Alberto; Baldonedo-Cernuda, Ricardo; Mosteiro-Díaz, María Pilar

    2015-01-01

    Anxiety experienced by women during their participation in breast cancer screening programs can condition their adherence to the program. The aim was to determine whether a brief nursing intervention could reduce anxiety before screening mammography. A randomized controlled trial carried out with 436 Spanish women aged between 50-69 years, who attended a population breast cancer screening program. The experimental group received an ad-hoc tailored intervention, which consisted of offering information about the screening program and the mammography exam, as well as of providing personal emotional support. Anxiety was assessed using the State-Trait Anxiety Inventory (STAI). Fear of screening outcome and fear of breast cancer were also assessed. Women of the experimental group had 60% less probability of having a high anxiety state (OR = 0.40; 95%: CI [0.25, 0.65]), after adjusting for sociodemographic and clinical variables. Regarding trait anxiety, no differences were observed between groups. The stratified analysis showed that this positive impact was greater in women who did not fear the screening outcome (OR = 0.24; 95% CI [0.11, 0.52]) or breast cancer (OR = 0.07; 95% CI [0.01, 0.41]). A protocolized nursing intervention reduced the probability of being anxious when undergoing a screening mammography.

  13. Using automated texture features to determine the probability for masking of a tumor on mammography, but not ultrasound.

    PubMed

    Häberle, Lothar; Hack, Carolin C; Heusinger, Katharina; Wagner, Florian; Jud, Sebastian M; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger; Wittenberg, Thomas; Fasching, Peter A

    2017-08-30

    Tumors in radiologically dense breast were overlooked on mammograms more often than tumors in low-density breasts. A fast reproducible and automated method of assessing percentage mammographic density (PMD) would be desirable to support decisions whether ultrasonography should be provided for women in addition to mammography in diagnostic mammography units. PMD assessment has still not been included in clinical routine work, as there are issues of interobserver variability and the procedure is quite time consuming. This study investigated whether fully automatically generated texture features of mammograms can replace time-consuming semi-automatic PMD assessment to predict a patient's risk of having an invasive breast tumor that is visible on ultrasound but masked on mammography (mammography failure). This observational study included 1334 women with invasive breast cancer treated at a hospital-based diagnostic mammography unit. Ultrasound was available for the entire cohort as part of routine diagnosis. Computer-based threshold PMD assessments ("observed PMD") were carried out and 363 texture features were obtained from each mammogram. Several variable selection and regression techniques (univariate selection, lasso, boosting, random forest) were applied to predict PMD from the texture features. The predicted PMD values were each used as new predictor for masking in logistic regression models together with clinical predictors. These four logistic regression models with predicted PMD were compared among themselves and with a logistic regression model with observed PMD. The most accurate masking prediction was determined by cross-validation. About 120 of the 363 texture features were selected for predicting PMD. Density predictions with boosting were the best substitute for observed PMD to predict masking. Overall, the corresponding logistic regression model performed better (cross-validated AUC, 0.747) than one without mammographic density (0.734), but less well

  14. Mammography Patient Information at Hospital Websites: Most Neither Comprehensible Nor Guideline Supported.

    PubMed

    Sadigh, Gelareh; Singh, Kush; Gilbert, Kirven; Khan, Ramsha; Duszak, Abigail M; Duszak, Richard

    2016-11-01

    Ongoing controversy regarding screening mammography guidelines has created confusion for many patients. Given recommendations that patient educational material be prepared at or below the 7th grade reading level of average Americans, the purpose of this study was to assess the readability of online mammography information offered by hospitals nationwide. During 2015, online mammography patient educational materials were identified for all Medicare-recognized hospitals nationwide for which screening mammography metrics were publicly available. Patient educational materials were assessed using six validated readability score algorithms. All references to official screening guidelines were captured. Of 4105 hospitals nationwide, 3252 had websites and confirmable screening mammography services. Of those, 1753 (54%) offered mammography information material online. Only 919 (28%) referenced any professional society guidelines. After excluding information not formatted in HTML and shorter than 100 words (to improve algorithm reliability), 1524 hospital mammography webpages were assessed for grade level scores. Nationally, the mean of each readability score for all hospitals varied between the 10th and 14th grade levels, all higher than the recommended 7th grade level (p < 0.001). At the individual hospital level, only 14 hospitals (0.4%) had mean scores at or below the 7th grade level. Of U.S. hospitals that offer screening mammography and have websites, only 54% provide online mammography educational material. Of those, only 0.4% present information at a reading level comprehensible to average Americans, and only 28% offer specific information to help patients reconcile conflicting guidelines. Health systems offering mammography should strive to better meet women's health information and literacy needs.

  15. Design and development of a fiber optic TDI CCD-based slot-scan digital mammography system

    NASA Astrophysics Data System (ADS)

    Toker, Emre; Piccaro, Michele F.

    1993-12-01

    We previously reported on the development, design, and clinical evaluation of a CCD-based, high performance, filmless imaging system for stereotactic needle biopsy procedures in mammography. The MammoVision system has a limited imaging area of 50 mm X 50 mm, since it is designed specifically for breast biopsy applications. We are currently developing a new filmless imaging system designed to cover the 18 cm X 24 cm imaging area required for screening and diagnostic mammography. The diagnostic mammography system is based on four 1100 X 330 pixel format, full-frame, scientific grade, front illuminated, MPP mode CCDs, with 24 micrometers X 24 micrometers square pixels Each CCD is coupled to an x-ray intensifying screen via a 1.7:1 fiber optic reducer. The detector assembly (180 mm long and 13.5 mm wide) is scanned across the patient's breast synchronously with the x-ray source, with the CCDs operated in time-delay integration (TDI) mode. The total scan time is 4.0 seconds.

  16. Design of a sensitive grating-based phase contrast mammography prototype (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Arboleda Clavijo, Carolina; Wang, Zhentian; Köhler, Thomas; van Stevendaal, Udo; Martens, Gerhard; Bartels, Matthias; Villanueva-Perez, Pablo; Roessl, Ewald; Stampanoni, Marco

    2017-03-01

    Grating-based phase contrast mammography can help facilitate breast cancer diagnosis, as several research works have demonstrated. To translate this technique to the clinics, it has to be adapted to cover a large field of view within a limited exposure time and with a clinically acceptable radiation dose. This indicates that a straightforward approach would be to install a grating interferometer (GI) into a commercial mammography device. We developed a wave propagation based optimization method to select the most convenient GI designs in terms of phase and dark-field sensitivities for the Philips Microdose Mammography (PMM) setup. The phase sensitivity was defined as the minimum detectable breast tissue electron density gradient, whereas the dark-field sensitivity was defined as its corresponding signal-to-noise Ratio (SNR). To be able to derive sample-dependent sensitivity metrics, a visibility reduction model for breast tissue was formulated, based on previous research works on the dark-field signal and utilizing available Ultra-Small-Angle X-ray Scattering (USAXS) data and the outcomes of measurements on formalin-fixed breast tissue specimens carried out in tube-based grating interferometers. The results of this optimization indicate the optimal scenarios for each metric are different and fundamentally depend on the noise behavior of the signals and the visibility reduction trend with respect to the system autocorrelation length. In addition, since the inter-grating distance is constrained by the space available between the breast support and the detector, the best way we have to improve sensitivity is to count on a small G2 pitch.

  17. Compositional breast imaging using a dual-energy mammography protocol

    PubMed Central

    Laidevant, Aurelie D.; Malkov, Serghei; Flowers, Chris I.; Kerlikowske, Karla; Shepherd, John A.

    2010-01-01

    Purpose: Mammography has a low sensitivity in dense breasts due to low contrast between malignant and normal tissue confounded by the predominant water density of the breast. Water is found in both adipose and fibroglandular tissue and constitutes most of the mass of a breast. However, significant protein mass is mainly found in the fibroglandular tissue where most cancers originate. If the protein compartment in a mammogram could be imaged without the influence of water, the sensitivity and specificity of the mammogram may be improved. This article describes a novel approach to dual-energy mammography, full-field digital compositional mammography (FFDCM), which can independently image the three compositional components of breast tissue: water, lipid, and protein. Methods: Dual-energy attenuation and breast shape measures are used together to solve for the three compositional thicknesses. Dual-energy measurements were performed on breast-mimicking phantoms using a full-field digital mammography unit. The phantoms were made of materials shown to have similar x-ray attenuation properties of the compositional compartments. They were made of two main stacks of thicknesses around 2 and 4 cm. Twenty-six thickness and composition combinations were used to derive the compositional calibration using a least-squares fitting approach. Results: Very high accuracy was achieved with a simple cubic fitting function with root mean square errors of 0.023, 0.011, and 0.012 cm for the water, lipid, and protein thicknesses, respectively. The repeatability (percent coefficient of variation) of these measures was tested using sequential images and was found to be 0.5%, 0.5%, and 3.3% for water, lipid, and protein, respectively. However, swapping the location of the two stacks of the phantom on the imaging plate introduced further errors showing the need for more complete system uniformity corrections. Finally, a preliminary breast image is presented of each of the compositional

  18. Response costs of mammography adherence: Iranian women's perceptions.

    PubMed

    Khodayarian, Mahsa; Mazloomi-Mahmoodabad, Seyed Saied; Lamyian, Minoor; Morowatisharifabad, Mohammad Ali; Tavangar, Hossein

    2016-01-01

    Mammography as the most common secondary prevention method has known to be helpful in detecting breast cancer at the early stages. Low level of participation among women toward mammography uptake due to cultural beliefs is a great concern. This study aimed at exploring the perceptions of women about response costs of mammography adherence (MA) in Yazd, Iran. A qualitative study using semi-structured interviews was performed. Fourteen women,one oncology nurse, and a breast cancer survivor were purposefully interviewed. Interviews were transcribed verbatim and analyzed by directed content analysis method based on protection motivation theory (PMT). One main theme was emerged from the analysis namely called "response costs".Two main categories were also emerged from the data; (1) psychological barriers with six subcategories including "embarrassment," "worry about being diagnosed with cancer," "preoccupation with underlying disease," "misconception about mammography," "need for an accompanying person," and "internalizing the experiences of the others," and (2) maladaptive coping modes which encompassed three subcategories: "religious faith," "fatalism," and"avoidance and denial." Useful information was provided about the response costs of mammography utilization based on the perceptions of women. Cognitive barriers may be decreased by conducting modifications in women's awareness and attitude toward MA as well as changing the national health system infrastructures. Incorporating religious and cultural belief systems into MA educational programs through motivational messages is recommended.

  19. Current applications and future direction of MR mammography.

    PubMed

    Kneeshaw, P J; Turnbull, L W; Drew, P J

    2003-01-13

    Compared with triple assessment for symptomatic and occult breast disease, magnetic resonance mammography (MRM) offers higher sensitivity for the detection of multifocal cancer, which is important in selecting patients appropriately for breast-conserving surgery. It is an ideal tool for the screening of patients with a high risk of breast cancer or where there is axillary disease or nipple discharge and conventional imaging has not revealed the primary focus. Techniques are now available to biopsy lesions only apparent on MRM. MRM can differentiate scar tissue from tumour; therefore, it is useful in patients in which there is possible recurrent disease. Clinical and X-ray mammographic assessment of response to neoadjuvant chemotherapy may be unreliable because of replacement of the tumour with scar tissue. MRM can identify responders and nonresponders with more accuracy. It is the modality of choice for the assessment of breast implants for rupture with accuracy higher than X-ray mammography and ultrasound. Advances in both spatial and temporal resolutions, the imaging sequences employed, pharmacokinetic modelling of contrast uptake, the use of dedicated and now phased-array breast coils, and gadolinium-based contrast agents have all played their part in the advancement of this imaging technique. Despite the limitations of patient compliance, scan-time and cost, this review describes how MRM has become a valuable tool in breast disease, especially in cases of diagnostic uncertainty. However, MRM must make the transition from research institutions into routine clinical practice.

  20. Method for inserting noise in digital mammography to simulate reduction in radiation dose

    NASA Astrophysics Data System (ADS)

    Borges, Lucas R.; de Oliveira, Helder C. R.; Nunes, Polyana F.; Vieira, Marcelo A. C.

    2015-03-01

    The quality of clinical x-ray images is closely related to the radiation dose used in the imaging study. The general principle for selecting the radiation is ALARA ("as low as reasonably achievable"). The practical optimization, however, remains challenging. It is well known that reducing the radiation dose increases the quantum noise, which could compromise the image quality. In order to conduct studies about dose reduction in mammography, it would be necessary to acquire repeated clinical images, from the same patient, with different dose levels. However, such practice would be unethical due to radiation related risks. One solution is to simulate the effects of dose reduction in clinical images. This work proposes a new method, based on the Anscombe transformation, which simulates dose reduction in digital mammography by inserting quantum noise into clinical mammograms acquired with the standard radiation dose. Thus, it is possible to simulate different levels of radiation doses without exposing the patient to new levels of radiation. Results showed that the achieved quality of simulated images generated with our method is the same as when using other methods found in the literature, with the novelty of using the Anscombe transformation for converting signal-independent Gaussian noise into signal-dependent quantum noise.

  1. Mammography screening: how important is cost as a barrier to use?

    PubMed Central

    Urban, N; Anderson, G L; Peacock, S

    1994-01-01

    OBJECTIVES. Recent legislation will improve insurance coverage for screening mammography and effectively lower its cost to many women. Although cost has been cited as a barrier to use, evidence of the magnitude of its effect on use is limited. METHODS. Mammography use in the past 2 years among women aged 50 to 75 residing in four suburban or rural counties in Washington State was estimated from 1989 survey data. Logistic regression analysis was used to estimate the odds ratio of mammography use as a function of economic and other variables. Within a residential area, averages were used to measure the market price of mammography and the time cost to obtain a mammogram. RESULTS. Use was lower among women who faced a higher net price or who preferred to obtain a mammogram during weekend or evening hours and higher among women with higher incomes. Visiting no doctor regularly and smoking were predictors of failure to use mammography. CONCLUSION. The effects of economic variables on mammography use are important and stable across subsets of the population, but they are modest in size. PMID:8279611

  2. Mammography screening: how important is cost as a barrier to use?

    PubMed

    Urban, N; Anderson, G L; Peacock, S

    1994-01-01

    Recent legislation will improve insurance coverage for screening mammography and effectively lower its cost to many women. Although cost has been cited as a barrier to use, evidence of the magnitude of its effect on use is limited. Mammography use in the past 2 years among women aged 50 to 75 residing in four suburban or rural counties in Washington State was estimated from 1989 survey data. Logistic regression analysis was used to estimate the odds ratio of mammography use as a function of economic and other variables. Within a residential area, averages were used to measure the market price of mammography and the time cost to obtain a mammogram. Use was lower among women who faced a higher net price or who preferred to obtain a mammogram during weekend or evening hours and higher among women with higher incomes. Visiting no doctor regularly and smoking were predictors of failure to use mammography. The effects of economic variables on mammography use are important and stable across subsets of the population, but they are modest in size.

  3. Socio-Cognitive Determinants of the Mammography Screening Uptake among Iranian Women

    PubMed

    Mirzaei-Alavijeh, Mehdi; Ghorbani, Parvaneh; Jalilian, Farzad

    2018-05-26

    Background: Mammography screening uptake is the most effective method in breast cancer screening. The aim of this study was to determine the determinants related to mammography screening uptake among Iranian women based on the theory of planned behavior. Materials and Methods: This cross-sectional study was conducted among 408 women who referred to health centers in Kermanshah city, the western of Iran, during 2016. Participants filled out a self-administered questionnaire. Data were analyzed by SPSS version 21 using Pearson correlation, linear and logistic regression statistical tests at 95% significant level. Results: The mean age of participants was 39.61 years [SD: 8.28], ranged from 30 to 60 years. Almost 13% of the participants had already mammography screening uptake at least once. Perceived behavioral control (OR=1.229) and behavioral intention (OR=1.283) were the more influential predictors on mammography screening uptake. Conclusions: Based on result, it seems increase perceived behavior control toward mammography screening uptake may be usefulness in promotion of mammography screening uptake among Iranian women. Creative Commons Attribution License

  4. Mammography and Other Screening Tests for Breast Problems

    MedlinePlus

    ... in eight women will develop breast cancer by age 75 years. Regular breast screening can help find cancer at an early and more curable stage. Screening also can find problems in the breasts that are not cancer. What is mammography? Mammography is the primary tool used to screen for breast cancer and ...

  5. Mammography performance in Oman: Review of factors influencing cancer yield and positive predictive value.

    PubMed

    Taif, Sawsan; Tufail, Fatma; Alnuaimi, Ahmed Sameer

    2016-06-01

    The aim of this study is to assess mammography performance in Oman by estimating the breast cancer rate and the positive predictive value (PPV) with the influence of some variables. This cross-sectional study was conducted on mammograms done in one of the three main breast imaging centers in Oman between January 2008 and July 2012. Diagnostic and screening groups were identified and assessed separately. Rate of abnormal mammograms, rate of breast cancer and the PPV were estimated according to Breast Imaging Reporting and Data System (BIRADS) score, presence of breast lump and patient's age. Total of 653 mammograms were included, 254 diagnostic and 399 screening. Abnormal mammograms (BIRADS 4 and 5) form 31.9% of the diagnostic examinations compared with 6.8% of screening examinations. Breast cancer was present in 17.9% of the diagnostic compared with 1.0% of the screening group. The PPV of BIRADS 5 was 94.1%, and for BIRADS 4 was 37.1 and 26.7% for diagnostic and screening studies. Overall PPV for abnormal mammograms was 65.2% in the diagnostic and 26.7% in the screening group. Mammography PPV shows positive association with age (P = 0.039) while presence of breast lump has no significant effect on the PPV (P = 0.38). BIRADS 5 score was found to have a high cancer yield making it a strong predictor of cancer. Different results were obtained in the diagnostic compared with screening mammography with higher rates of abnormal mammograms and breast cancer. Mammography performance should be better in the older women. © 2014 Wiley Publishing Asia Pty Ltd.

  6. Shielding requirements for mammography.

    PubMed

    Simpkin, D J

    1987-09-01

    Shielding requirements for mammography installations have been investigated. To apply the methodologies of NCRP Report No. 49, the scatter-to-incident ratio of a typical mammography beam was measured, and the broad beam transmission was calculated for several representative beam spectra. These calculations were found to compare favorably with published low kVp tungsten-targeted x-ray transmission through a variety of shielding materials. Radiation shielding tables were developed from the calculated transmissions through Pb, concrete, gypsum, steel, plate glass, and water, using a technique which eliminates the "add one HVL" rule. It is concluded that Mo-targeted x-ray beams operated at 35 kVp require half the shielding of W-targeted beams operated at 50 kVp, and that adequate, cost-effective shielding calculations will consider alternatives to Pb.

  7. Lesion detectability in 2D-mammography and digital breast tomosynthesis using different targets and observers

    NASA Astrophysics Data System (ADS)

    Elangovan, Premkumar; Mackenzie, Alistair; Dance, David R.; Young, Kenneth C.; Wells, Kevin

    2018-05-01

    This work investigates the detection performance of specialist and non-specialist observers for different targets in 2D-mammography and digital breast tomosynthesis (DBT) using the OPTIMAM virtual clinical trials (VCT) Toolbox and a 4-alternative forced choice (4AFC) assessment paradigm. Using 2D-mammography and DBT images of virtual breast phantoms, we compare the detection limits of simple uniform spherical targets and irregular solid masses. Target diameters of 4 mm and 6 mm have been chosen to represent target sizes close to the minimum detectable size found in breast screening, across a range of controlled contrast levels. The images were viewed by a set of specialist observers (five medical physicists and six experienced clinical readers) and five non-specialists. Combined results from both observer groups indicate that DBT has a significantly lower detectable threshold contrast than 2D-mammography for small masses (4 mm: 2.1% [DBT] versus 6.9% [2D]; 6 mm: 0.7% [DBT] versus 3.9% [2D]) and spheres (4 mm: 2.9% [DBT] versus 5.3% [2D]; 6 mm: 0.3% [DBT] versus 2.2% [2D]) (p  <  0.0001). Both observer groups found spheres significantly easier to detect than irregular solid masses for both sizes and modalities (p  <  0.0001) (except 4 mm DBT). The detection performances of specialist and non-specialist observers were generally found to be comparable, where each group marginally outperformed the other in particular detection tasks. Within the specialist group, the clinical readers performed better than the medical physicists with irregular masses (p  <  0.0001). The results indicate that using spherical targets in such studies may produce over-optimistic detection thresholds compared to more complex masses, and that the superiority of DBT for detecting masses over 2D-mammography has been quantified. The results also suggest specialist observers may be supplemented by non-specialist observers (with training) in some types of 4AFC studies.

  8. The Future of Mammography: Radiology Residents’ Experiences, Attitudes, and Opinions

    PubMed Central

    Baxi, Shrujal S.; Snow, Jacqueline G.; Liberman, Laura; Elkin, Elena B.

    2011-01-01

    OBJECTIVE The objective of our study was to assess the experiences and preferences of radiology residents with respect to breast imaging. MATERIALS AND METHODS We surveyed radiology residents at 26 programs in New York and New Jersey. Survey topics included plans for subspecialty training, beliefs, and attitudes toward breast imaging and breast cancer screening and the likelihood of interpreting mammography in the future. RESULTS Three hundred forty-four residents completed the survey (response rate, 62%). The length of time spent training in breast imaging varied from no dedicated time (37%) to 1–8 weeks (40%) to more than 9 weeks (23%). Most respondents (97%) agreed that mammography is important to women’s health. More than 85% of residents believed that mammography should be interpreted by breast imaging specialists. Respondents shared negative views about mammography, agreeing with statements that the field was associated with a high risk of malpractice (99%), stress (94%), and low reimbursement (68%). Respondents endorsed several positive attributes of mammography, including job availability (97%), flexible work schedules (94%), and few calls or emergencies (93%). Most radiology residents (93%) said that they were likely to pursue subspecialty training, and 7% expressed interest in breast imaging fellowships. CONCLUSION Radiology residents’ negative and positive views about mammography seem to be independent of time spent training in mammography and of future plans to pursue fellowship training in breast imaging. Systematic assessment of the plans and preferences of radiology residents can facilitate the development of strategies to attract trainees to careers in breast imaging. PMID:20489113

  9. Area-level socioeconomic inequalities in the use of mammography screening: A multilevel analysis of the Health of Houston Survey

    PubMed Central

    Calo, William A.; Vernon, Sally W.; Lairson, David R.; Linder, Stephen H.

    2015-01-01

    Background An emerging literature reports that women who reside in socioeconomically deprived communities are less likely to adhere to mammography screening. This study explored associations between area-level socioeconomic measures and mammography screening among a racially and ethnically diverse sample of women in Texas. Methods We conducted a cross-sectional multilevel study linking individual-level data from the 2010 Health of Houston Survey and contextual data from the U.S. Census. Women ages 40–74 years (N=1,541) were included in the analyses. We examined tract-level poverty, unemployment, education, Hispanic and Black composition, female-headed householder families, and crowding as contextual measures. Using multilevel logistic regression modeling, we compared most disadvantaged tracts (quartiles 2–4) to the most advantaged tract (quartile 1). Results Overall, 64% of the sample was adherent to mammography screening. Screening rates were lower (P<.05) among Hispanics, those foreign born, women aged 40–49 years, and those with low educational attainment, unemployed, and without health insurance coverage. Women living in areas with high levels of poverty (quartile 2 vs. quartile 1: OR=0.50; 95% CI: 0.30–0.85), Hispanic composition (quartile 3 vs. quartile 1: OR=0.54; 95% CI: 0.32–0.90), and crowding (quartile 4 vs. quartile 1: OR=0.53; 95% CI: 0.29–0.96) were less likely to have up-to-date mammography screening, net of individual-level factors. Conclusion Our findings highlight the importance of examining area-level socioeconomic inequalities in mammography screening. The study represents an advance on previous research because we examined multiple area measures, controlled for key individual-level covariates, used data aggregated at the tract level, and accounted for the nested structure of the data. PMID:26809487

  10. Measuring preparedness for mammography in women with intellectual disabilities: a validation study of the Mammography Preparedness Measure.

    PubMed

    Wang, Claire Tienwey; Greenwood, Nechama; White, Laura F; Wilkinson, Joanne

    2015-05-01

    Women with intellectual disabilities have similar breast cancer rates as the general population, but lower rates of regular mammography and higher breast cancer mortality rates. Although prior qualitative work demonstrates that women with intellectual disabilities face unique, disability-specific barriers to mammography, the present authors lack standardized, validated instruments for measuring knowledge of breast cancer screening in this population. In addition, much research related to adults with intellectual disabilities focuses on family or carer perspectives, rather than involving women with intellectual disabilities, themselves. The present authors first pilot tested a general population instrument measuring breast cancer knowledge, and found that it did not perform adequately in women with intellectual disabilities. In response, the present authors developed the Mammography Preparedness Measure (MPM), a direct short interview tool to measure knowledge and preparedness in women with intellectual disabilities, themselves, rather than relying on caregiver or other reports, and using inclusive methodology. The present authors validated the MPM by assessing test-retest reliability. Average test-retest per cent agreement of 84%, ranging from 74 to 91% agreement per item, with an overall kappa of 0.59. The MPM appears to be a valid instrument appropriate for measuring mammography preparedness in women with intellectual disabilities. The success of this innovative tool suggests that direct, rather than informant-directed tools can be developed to measure health knowledge and cancer screening readiness in adults with intellectual disabilities, an important measure in studying and reducing disparities. © 2014 John Wiley & Sons Ltd.

  11. Decision making and counseling around mammography screening for women aged 80 or older.

    PubMed

    Schonberg, Mara A; Ramanan, Radhika A; McCarthy, Ellen P; Marcantonio, Edward R

    2006-09-01

    Despite uncertain benefit, many women over age 80 (oldest-old) receive screening mammography. To explore decision-making and physician counseling of oldest-old women around mammography screening. Qualitative research using in-depth semi-structured interviews. Twenty-three women aged 80 or older who received care at a large academic primary care practice (13 had undergone mammography screening in the past 2 years) and 16 physicians at the same center. We asked patients and physicians to describe factors influencing mammography screening decisions of oldest-old women. We asked physicians to describe their counseling about screening to the oldest-old. Patients and/or physicians identified the importance of physician influence, patient preferences, system factors, and social influences on screening decisions. Although physicians felt that patient's health affected screening decisions, few patients felt that health mattered. Three types of elderly patients were identified: (1) women enthusiastic about screening mammography; (2) women opposed to screening mammography; and (3) women without a preference who followed their physician's recommendation. However, physician counseling about mammography screening to elderly women varies; some individualize discussions; others encourage screening; few discourage screening. Physicians report that discussions about stopping screening can be uncomfortable and time consuming. Physicians suggest that more data could facilitate these discussions. Some oldest-old women have strong opinions about screening mammography while others are influenced by physicians. Discussions about stopping screening are challenging for physicians. More data about the benefits and risks of mammography screening for women aged 80 or older could inform patients and improve provider counseling to lead to more rational use of mammography.

  12. Effects of digital mammography uptake on downstream breast-related care among older women.

    PubMed

    Hubbard, Rebecca A; Zhu, Weiwei; Onega, Tracy L; Fishman, Paul; Henderson, Louise M; Tosteson, Anna N A; Buist, Diana S M

    2012-12-01

    Digital mammography is the dominant modality for breast cancer screening in the United States. No previous studies have investigated as to how introducing digital mammography affects downstream breast-related care. Compare breast-related health care use after a screening mammogram before and after introduction of digital mammography. Longitudinal study of screening mammograms from 14 radiology facilities contributing data to the Breast Cancer Surveillance Consortium performed 1 year before and 4 years after each facility introduced digital mammography, along with linked Medicare claims. We included 30,211 mammograms for women aged 66 years and older without breast cancer. Rates of false-positive recall and short-interval follow-up were based on radiologists' assessments and recommendations; rates of follow-up mammography, ultrasound, and breast biopsy use were based on Medicare claims. False-positive recall rates increased after the introduction of digital mammography. Follow-up mammography use was significantly higher across all 4 years after a facility began using digital mammography compared with the year before [year 1 odds ratio (OR) = 1.7, 95% confidence interval (CI), 1.4-2.1]. Among women with false-positive mammography results, use of ultrasound decreased significantly in the second through fourth years after digital mammography began (year 2 OR = 0.4, 95% CI, 0.3-0.6). Introduction of a new technology led to changes in health care use that persisted for at least 4 years. Comparative effectiveness research on new technologies should consider not only diagnostic performance but also downstream utilization attributable to this apparent learning curve.

  13. Update on new technologies in digital mammography

    PubMed Central

    Patterson, Stephanie K; Roubidoux, Marilyn A

    2014-01-01

    Despite controversy regarding mammography’s efficacy, it continues to be the most commonly used breast cancer-screening modality. With the development of digital mammography, some improved benefit has been shown in women with dense breast tissue. However, the density of breast tissue continues to limit the sensitivity of conventional mammography. We discuss the development of some derivative digital technologies, primarily digital breast tomosynthesis, and their strengths, weaknesses, and potential patient impact. PMID:25152634

  14. Does telephone scheduling assistance increase mammography screening adherence?

    PubMed

    Payton, Colleen A; Sarfaty, Mona; Beckett, Shirley; Campos, Carmen; Hilbert, Kathleen

    2015-11-01

    The 2 objectives were: 1) describe the use of a patient navigation process utilized to promote adherence to mammography screening within a primary care practice, and 2) determine the result of the navigation process and estimate the time required to increase mammography screening with this approach in a commercially insured patient population enrolled in a health maintenance organization. An evaluation of a nonrandomized practice improvement intervention. Women eligible for mammography (n = 298) who did not respond to 2 reminder letters were contacted via telephone by a navigator who offered scheduling assistance for mammography screening. The patient navigator scheduled appointments, documented the number of calls, and confirmed completed mammograms in the electronic health record, as well as estimated the time for calls and chart review. Of the 188 participants reached by phone, 112 (59%) scheduled appointments using the patient navigator, 35 (19%) scheduled their own appointments independently prior to the call, and 41 (22%) declined. As a result of the telephone intervention, 78 of the 188 women reached (41%) received a mammogram; also, all 35 women who had independently scheduled a mammogram received one. Chart documentation confirmed that 113 (38%) of the cohort of 298 women completed a mammogram. The estimated time burden for the entire project was 55 hours and 33 minutes, including calling patients, scheduling appointments, and chart review. A patient navigator can increase mammography adherence in a previously nonadherent population by making the screening appointment while the patient is on the phone.

  15. Educational interventions to improve screening mammography interpretation: a randomized, controlled trial

    PubMed Central

    BM, Geller; A, Bogart; PA, Carney; EA, Sickles; RA, Smith; B, Monsees; LW, Bassett; DM, Buist; K, Kerlikowske; T, Onega; B, Yankaskas; S, Haneuse; DA, Hill; M, Wallis; DL, Miglioretti

    2014-01-01

    Purpose Conduct a randomized controlled trial of educational interventions to improve performance of screening mammography interpretation. Materials and Methods We randomly assigned physicians who interpret mammography to one of three groups: (1) self-paced DVD; (2) live, expert-led educational session; or (3) control. The DVD and live interventions used mammography cases of varying difficulty and associated teaching points. Interpretive performance was compared using a pre-/post-test design. Sensitivity, specificity, and positive predictive value (PPV) were calculated relative to two outcomes: cancer status and consensus of three experts about recall, and each were compared using logistic regression adjusting for pre-test performance. Results 102 radiologists completed all aspects of the trial. After adjustment for pre-intervention performance, the odds of improved sensitivity for correctly identifying a lesion relative to expert recall were 1.34 times higher for DVD participants than controls (95% confidence interval [CI]: 1.00, 1.81; P=0.050). The odds of improved PPV for correctly identifying a lesion relative to both expert recall (odds ratio [OR]=1.94, 95% CI: 1.24, 3.05; P=0.004) and cancer status (OR=1.81, 95% CI: 1.01, 3.23; P=0.045) were significantly improved for DVD participants compared to controls with no significant change in specificity. For the live-intervention group, specificity was significantly lower than the control group (OR relative to expert recall=0.80; 95% CI: 0.64, 1.00; P=0.048; OR relative to cancer=0.79; 95% CI: 0.65, 0.95; P=0.015). Conclusion In this randomized controlled trial, the DVD educational intervention resulted in a significant improvement in mammography interpretive screening performance on a test-set, which could translate into improved clinical interpretative performance. PMID:24848854

  16. Educational interventions to improve screening mammography interpretation: a randomized controlled trial.

    PubMed

    Geller, Berta M; Bogart, Andy; Carney, Patricia A; Sickles, Edward A; Smith, Robert; Monsees, Barbara; Bassett, Lawrence W; Buist, Diana M; Kerlikowske, Karla; Onega, Tracy; Yankaskas, Bonnie C; Haneuse, Sebastien; Hill, Deirdre; Wallis, Matthew G; Miglioretti, Diana

    2014-06-01

    The objective of our study was to conduct a randomized controlled trial of educational interventions that were created to improve performance of screening mammography interpretation. We randomly assigned physicians who interpret mammography to one of three groups: self-paced DVD, live expert-led educational seminar, or control. The DVD and seminar interventions used mammography cases of varying difficulty and provided associated teaching points. Interpretive performance was compared using a pretest-posttest design. Sensitivity, specificity, and positive predictive value (PPV) were calculated relative to two outcomes: cancer status and consensus of three experts about recall. The performance measures for each group were compared using logistic regression adjusting for pretest performance. One hundred two radiologists completed all aspects of the trial. After adjustment for preintervention performance, the odds of improved sensitivity for correctly identifying a lesion relative to expert recall were 1.34 times higher for DVD participants than for control subjects (95% CI, 1.00-1.81; p = 0.050). The odds of an improved PPV for correctly identifying a lesion relative to both expert recall (odds ratio [OR] = 1.94; 95% CI, 1.24-3.05; p = 0.004) and cancer status (OR = 1.81; 95% CI, 1.01-3.23; p = 0.045) were significantly improved for DVD participants compared with control subjects, with no significant change in specificity. For the seminar group, specificity was significantly lower than the control group (OR relative to expert recall = 0.80; 95% CI, 0.64-1.00; p = 0.048; OR relative to cancer status = 0.79; 95% CI, 0.65-0.95; p = 0.015). In this randomized controlled trial, the DVD educational intervention resulted in a significant improvement in screening mammography interpretive performance on a test set, which could translate into improved interpretative performance in clinical practice.

  17. At what age should screening mammography be recommended for Asian women?

    PubMed

    Tsuchida, Junko; Nagahashi, Masayuki; Rashid, Omar M; Takabe, Kazuaki; Wakai, Toshifumi

    2015-07-01

    Although regular screening mammography has been suggested to be associated with improvements in the relative survival of breast cancer in recent years, the appropriate age to start screening mammography remains controversial. In November 2009, the United States Preventive Service Task Force published updated guidelines for breast cancer, which no longer support routine screening mammography for women aged 40-49 years, but instead, defer the choice of screening in that age group to the patient and physician. The age to begin screening differs between guidelines, including those from the Task Force, the American Cancer Society and the World Health Organization. It remains unclear how this discrepancy impacts patient survival, especially among certain subpopulations. Although the biological characteristics of breast cancer and peak age of incidence differ among different ethnic populations, there have been few reports that evaluate the starting age for screening mammography based on ethnicity. Here, we discuss the benefits and harm of screening mammography in the fifth decade, and re-evaluate the starting age for screening mammography taking ethnicity into account, focusing on the Asian population. Breast cancer incidence peaked in the fifth decade in Asian women, which has been thought to be due to a combination of biological and environmental factors. Previous reports suggest that Asian women in their 40s may receive more benefit and less harm from screening mammography than the age-matched non-Asian US population. Therefore, starting screening mammography at age 40 may be beneficial for women of Asian ethnicity in well-resourced countries, such as Japanese women who reside in Japan. © 2015 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  18. Mammography screening trends: the perspective of African American women born pre/post World War II.

    PubMed

    Williams, Karen Patricia; Mabiso, Athur; Lo, Yun-Jia; Penner, Louis A

    2010-06-01

    Researchers have traditionally combined aging women (aged > or =50 years) when reporting their mammography use. This may inadvertently mask important cohort effects in mammography use, which are likely to result from distinct personal life experiences and generational differences. Using the Health and Retirement Study samples of 1998, 2000, and 2004, we examined cohort differences in mammography use between African American women born before 1946 (non-baby boomers) and those born in 1946 to 1953 (baby boomers). Between 1998 and 2004, screening rates for non-baby boomers declined, while those for baby boomers remained relatively steady. Hierarchical linear modeling (HLM) analyses suggest that while screening rates decreased with age (OR, 0.957; 95% CI, 0.947-0.968) cohort effects may have partially reversed the age effect, with non-baby boomers having an increased likelihood of receiving a mammogram compared to baby boomers (OR, 1.697; 95% CI, 1.278-2.254). Because African American women are diagnosed at later stages of breast cancer, documentation of cohort differences in mammography use among older African American women is important as health care professionals design intervention programs that are maximally effective for women from different cohorts. This is particularly critical as more African American women in the baby boomer cohort become part of the aging population.

  19. Factors influencing elderly women's mammography screening decisions: implications for counseling.

    PubMed

    Schonberg, Mara A; McCarthy, Ellen P; York, Meghan; Davis, Roger B; Marcantonio, Edward R

    2007-11-16

    Although guidelines recommend that clinicians consider life expectancy before screening older women for breast cancer, many older women with limited life expectancies are screened. We aimed to identify factors important to mammography screening decisions among women aged 80 and older compared to women aged 65-79. Telephone surveys of 107 women aged 80+ and 93 women aged 65-79 randomly selected from one academic primary care practice who were able to communicate in English (60% response rate). The survey addressed the following factors in regards to older women's mammography screening decisions: perceived importance of a history of breast disease, family history of breast cancer, doctor's recommendations, habit, reassurance, previous experience, mailed reminder cards, family/friend's recommendations or experience with breast cancer, age, health, and media. The survey also assessed older women's preferred role in decision making around mammography screening. Of the 200 women, 65.5% were non-Hispanic white and 82.8% were in good to excellent health. Most (81.3%) had undergone mammography in the past 2 years. Regardless of age, older women ranked doctor's recommendations as the most important factor influencing their decision to get screened. Habit and reassurance were the next two highly ranked factors influencing older women to get screened. Among women who did not get screened, women aged 80 and older ranked age and doctor's counseling as the most influential factors and women aged 65-79 ranked a previous negative experience with mammography as the most important factor. There were no significant differences in preferred role in decision-making around mammography screening by age, however, most women in both age groups preferred to make the final decision on their own (46.6% of women aged 80+ and 50.5% of women aged 65-79). While a doctor's recommendation is the most important factor influencing elderly women's mammography screening decisions, habit and reassurance

  20. Rayleigh imaging in spectral mammography

    NASA Astrophysics Data System (ADS)

    Berggren, Karl; Danielsson, Mats; Fredenberg, Erik

    2016-03-01

    Spectral imaging is the acquisition of multiple images of an object at different energy spectra. In mammography, dual-energy imaging (spectral imaging with two energy levels) has been investigated for several applications, in particular material decomposition, which allows for quantitative analysis of breast composition and quantitative contrast-enhanced imaging. Material decomposition with dual-energy imaging is based on the assumption that there are two dominant photon interaction effects that determine linear attenuation: the photoelectric effect and Compton scattering. This assumption limits the number of basis materials, i.e. the number of materials that are possible to differentiate between, to two. However, Rayleigh scattering may account for more than 10% of the linear attenuation in the mammography energy range. In this work, we show that a modified version of a scanning multi-slit spectral photon-counting mammography system is able to acquire three images at different spectra and can be used for triple-energy imaging. We further show that triple-energy imaging in combination with the efficient scatter rejection of the system enables measurement of Rayleigh scattering, which adds an additional energy dependency to the linear attenuation and enables material decomposition with three basis materials. Three available basis materials have the potential to improve virtually all applications of spectral imaging.

  1. Potential Cost Savings of Contrast-Enhanced Digital Mammography.

    PubMed

    Patel, Bhavika K; Gray, Richard J; Pockaj, Barbara A

    2017-06-01

    The purpose of this article is to discuss whether the sensitivity and specificity of contrast-enhanced digital mammography (CEDM) render it a viable diagnostic alternative to breast MRI. That CEDM couples low-energy images (comparable to the diagnostic quality of standard mammography) and subtracted contrast-enhanced mammograms make it a cost-effective modality and a realistic substitute for the more costly breast MRI.

  2. Digital mammography, cancer screening: Factors important for image compression

    NASA Technical Reports Server (NTRS)

    Clarke, Laurence P.; Blaine, G. James; Doi, Kunio; Yaffe, Martin J.; Shtern, Faina; Brown, G. Stephen; Winfield, Daniel L.; Kallergi, Maria

    1993-01-01

    The use of digital mammography for breast cancer screening poses several novel problems such as development of digital sensors, computer assisted diagnosis (CAD) methods for image noise suppression, enhancement, and pattern recognition, compression algorithms for image storage, transmission, and remote diagnosis. X-ray digital mammography using novel direct digital detection schemes or film digitizers results in large data sets and, therefore, image compression methods will play a significant role in the image processing and analysis by CAD techniques. In view of the extensive compression required, the relative merit of 'virtually lossless' versus lossy methods should be determined. A brief overview is presented here of the developments of digital sensors, CAD, and compression methods currently proposed and tested for mammography. The objective of the NCI/NASA Working Group on Digital Mammography is to stimulate the interest of the image processing and compression scientific community for this medical application and identify possible dual use technologies within the NASA centers.

  3. Development of silica-encapsulated silver nanoparticles as contrast agents intended for dual-energy mammography.

    PubMed

    Karunamuni, Roshan; Naha, Pratap C; Lau, Kristen C; Al-Zaki, Ajlan; Popov, Anatoliy V; Delikatny, Edward J; Tsourkas, Andrew; Cormode, David P; Maidment, Andrew D A

    2016-09-01

    Dual-energy (DE) mammography has recently entered the clinic. Previous theoretical and phantom studies demonstrated that silver provides greater contrast than iodine for this technique. Our objective was to characterize and evaluate in vivo a prototype silver contrast agent ultimately intended for DE mammography. The prototype silver contrast agent was synthesized using a three-step process: synthesis of a silver core, silica encapsulation and PEG coating. The nanoparticles were then injected into mice to determine their accumulation in various organs, blood half-life and dual-energy contrast. All animal procedures were approved by the institutional animal care and use committee. The final diameter of the nanoparticles was measured to be 102 (±9) nm. The particles were removed from the vascular circulation with a half-life of 15 min, and accumulated in macrophage-rich organs such as the liver, spleen and lymph nodes. Dual-energy subtraction techniques increased the signal difference-to-noise ratio of the particles by as much as a factor of 15.2 compared to the single-energy images. These nanoparticles produced no adverse effects in mice. Silver nanoparticles are an effective contrast agent for dual-energy x-ray imaging. With further design improvements, silver nanoparticles may prove valuable in breast cancer screening and diagnosis. • Silver has potential as a contrast agent for DE mammography. • Silica-coated silver nanoparticles are biocompatible and suited for in vivo use. • Silver nanoparticles produce strong contrast in vivo using DE mammography imaging systems.

  4. Dual-energy contrast-enhanced spectral mammography (CESM).

    PubMed

    Daniaux, Martin; De Zordo, Tobias; Santner, Wolfram; Amort, Birgit; Koppelstätter, Florian; Jaschke, Werner; Dromain, Clarisse; Oberaigner, Willi; Hubalek, Michael; Marth, Christian

    2015-10-01

    Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.

  5. Determinants of the number of mammography units in 31 countries with significant mammography screening

    PubMed Central

    Autier, P; Ouakrim, D A

    2008-01-01

    In the 2000s, most of the female population of industrialised countries had access to mammography breast cancer screening, but with variable modalities among the countries. We assessed the number of mammography units (MUs) in 31 European, North American and Asian countries where significant mammography activity has existed for over 10 years, collecting data on the number of such units and of radiologists by contacting institutions in each country likely to provide the relevant information. Around 2004, there were 32 324 MU in 31 countries, the number per million women ranging from less than 25 in Turkey, Denmark, the Netherlands, the United Kingdom, Norway, Poland and Hungary to more than 80 in Cyprus, Italy, France, the United States and Austria. In a multivariate analysis, the number of MUs was positively associated with the number of radiologists (P=0.0081), the number of women (P=0.0023) and somewhat with the country surface area (P=0.077). There is considerable variation in the density of MU across countries and the number of MUs in service are often well above what would be necessary according to local screening recommendations. High number of MUs in some countries may have undesirable consequences, such as unnecessarily high screening frequency and decreased age at which screening is started. PMID:18781176

  6. Magnetic resonance mammography in comparison with mammography in the discovery of multifocal, multicentric and bilateral lesions of breast cancer.

    PubMed

    Bakhtavar, Khadijeh; Saran, Maryam; Behzadifar, Masoud; Farsi, Maryam

    2017-08-01

    Breast cancer is one of the health system problems and important diseases that is rising in developing and advanced countries. This study aimed to determine the difference of Magnetic Resonance Mammography (MRM) findings versus mammography in detecting multifocal, multi-centric and malignant bilateral lesions in patients with known breast cancer in Tehran. This cross-sectional study was conducted in Iran and Tehran among breast cancer patients between January 2015 and February 2016. Patients were included in the study prior to surgery, at the request of a surgeon with the aim of detecting multifocal, multi-centric and bilateral lesions. Demographic information was also collected from patients. The results for quantitative variables were expressed as mean and standard deviations, and for qualitative variables, were expressed as relative and absolute frequency. Chi-square test was used to compare the two methods. SPSS Ver.24 (IBM) software was used to analyze the data. Thirty-nine patients were enrolled in the study. The mean age of patients in this study was 48.46±6.836. In mammography, 13 (33.3%) had Composition C and 26 (66.7%) had Composition D according to the type of Composition. In total, 25 patients (89.3%) had one lesion and 3 patients (10.7%) had more than two lesions. In MRM, all lesions observed were mass (54 masses). The number of lesions found in MRM was 27 patients with one lesion (58.9%), 6 patients with two lesions (20.5%) and 5 patients with three lesions (20.6%). MRM detected more lesions compared to mammography (p<0.0001). The value of Chi-square test with a degree of freedom and error level of 0.05 was 3.71 and p<0.0001 that showed a significant relationship between the number of MRM findings in comparison with mammography. The results of our study showed that two or more lesions and bilateral lesions in MRM were more than mammography in women with B Breast Composition C, D; the findings showed that MRM has a better ability to detect breast

  7. Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems

    NASA Astrophysics Data System (ADS)

    Wood, Tim J.; Moore, Craig S.; Saunderson, John R.; Beavis, Andrew W.

    2018-01-01

    Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a useful metric for the optimisation of clinical imaging systems. The aim of this study was to develop a methodology for measuring eDQE and eDE on a Philips microdose mammography (MDM) L30 photon counting scanning system, and to compare performance with two conventional flat panel systems. A custom made lead-blocker was manufactured to enable the accurate determination of dose measurements, and modulation transfer functions were determined free-in-air at heights of 2, 4 and 6 cm above the breast support platform. eDQE were calculated for a Philips MDM L30, Hologic Dimensions and Siemens Inspiration digital mammography system for 2, 4 and 6 cm thick poly(methyl methacrylate) (PMMA). The beam qualities (target/filter and kilovoltage) assessed were those selected by the automatic exposure control, and anti-scatter grids were used where available. Measurements of eDQE demonstrate significant differences in performance between the slit- and scan-directions for the photon counting imaging system. MTF has been shown to be the limiting factor in the scan-direction, which results in a rapid fall in eDQE at mid-to-high spatial frequencies. A comparison with two flat panel mammography systems demonstrates that this may limit image quality for small details, such as micro-calcifications, which correlates with a more conventional image quality assessment with the CDMAM phantom. eDE has shown the scanning photon counting system offers superior performance for low spatial frequencies, which will be important for the detection of large low contrast masses. Both eDQE and eDE are proposed as useful metrics that should enable optimisation of the Philips MDM L30.

  8. Self-Report Versus Medical Record for Mammography Screening Among Minority Women.

    PubMed

    Nandy, Karabi; Menon, Usha; Szalacha, Laura A; Park, HanJong; Lee, Jongwon; Lee, Eunice E

    2016-12-01

    Self-report is the most common means of obtaining mammography screening data. The purpose of this study was to assess the accuracy of minority women's self-reported mammography by comparing their self-reported dates of mammograms with those in their medical records from a community-based randomized control trial. We found that out of 192 women, 116 signed the Health Information Portability and Accountability Act form and, among these, 97 had medical records that could be verified (97 / 116 = 83.6%). Ninety-two records matched where both sources confirmed a mammogram; 48 of 92 (52.2%) matched perfectly on self-reported date of mammogram. Complexities in the verification process warrant caution when verifying self-reported mammography screening in minority populations. In spite of some limitations, our findings support the usage of self-reported data on mammography as a validated tool for other researchers investigating mammography screening among minority women who continue to have low screening rates. © The Author(s) 2016.

  9. Patterns and determinants of mammography screening in Lebanese women.

    PubMed

    Elias, Nadia; Bou-Orm, Ibrahim R; Adib, Salim M

    2017-03-01

    The associations of ever using and/or repeating a mammography test with psychosocial and socio-demographic factors were surveyed in 2014 among Lebanese women ≥ 40. A sample of 2400 women was selected across Lebanon. Variables with significant bivariate associations with various types of behaviors were entered in multivariate analysis. Of the total, 105 women (4·4%) had never heard of mammography as a tool for early breast cancer detection. Among the remaining 2295, 45% had ever used it, of whom 10% had obtained it for the first time within the 12 months preceding the survey. Repeaters were 67% of 926 women who had the time opportunity to do so (median lifetime frequency: 2). Older age, higher socio-economic status (SES) and living within the Greater Beirut (GB) area were significantly associated with ever-use. Within GB, psychosocial factors such as perceived susceptibility and benefits were most strongly associated with ever-use. Outside GB, socio-economic advantage seemed to mostly affect ever-use. Only 4% reported opposition from husbands to their mammography, and husband's support was significant for adherence to mammography guidelines mostly outside GB. Higher education emerged also as a significant socio-demographic determinant for ever-repeating in all regions. Perceived comfort of the previous test strongly affected the likelihood of repeating it. Providing mammography free-of-charge may alleviate some obstacles among women with socio-economic disadvantage. Stressing that good results one year do not make the cancer less likely or repeating the test less important, as well as improving the comfort of mammography testing could ensure test repeating.

  10. TU-D-209-01: Dosimetry of Diagnostic Work Up Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jallow, N; Sechopoulos, I

    2016-06-15

    Purpose: To investigate patient average glandular dose (AGD) characteristics of diagnostic mammography. Methods: The techniques used to image 14420 patients who received diagnostic work up mammography from October 2008 to December 2014 at one academic hospital were retrospectively collected. The most common diagnostic views and the techniques used for each according to compressed breast thickness were determined. For all techniques, 1st half value layer and air kerma output per tube current-exposure time product were measured; then the incident air kerma for each acquisition was calculated. The values for normalized glandular dose (DgN) were obtained with a validated Monte Carlo simulationmore » of mammographic acquisition. The mono-energetic DgN results were combined according to relative fluence using the TASMICS model to obtain DgN coefficients for each spectrum. The spectral DgN and calculated incident air kerma were used to estimate AGD of patients with breast thickness ranging from 2 to 8 cm. Results: The most common views utilized during diagnostic mammography were magnification craniocaudal (24%), magnification mediolateral (19%), spot craniocaudal (28%), and spot mediolateral oblique (24%). The AGD increased with increasing breast thickness for both the magnification and spot views. The AGD for a 5.5 cm thick breast was approximately 6.8 mGy and 2.2 mGy for the magnification and spot views, respectively. The AGD ranged from 3.6 mGy to 6.8 mGy for the magnification views and from 1.0 mGy to 3.1 mGy for spot views. The difference in AGD between the two magnification views or the two spot views was not significant. Conclusion: These results provide information on breast dose to which screening recalled women are exposed to. In addition to understanding the dose used for common clinical imaging tests, this data could be used when comparing use of mammography for diagnostic workup to other potential modalities, such as breast tomosynthesis and breast CT.« less

  11. The personal costs and convenience of screening mammography.

    PubMed

    Suter, Lisa Gale; Nakano, Connie Y; Elmore, Joann G

    2002-09-01

    Few studies have examined the impact of women's personal costs on obtaining a screening mammogram in the United States. All women obtaining screening mammograms at nine Connecticut mammography facilities during a 2-week study period were asked to complete a questionnaire. Facilities included urban and rural fixed sites and mobile sites. The survey included questions about insurance coverage, mammogram payment, and personal costs in terms of transportation, family care, parking, and lost work time from the women's perspective. The response rate was 62% (731 of 1189). Thirty-two percent of respondents incurred some type of personal cost, including lost work time, family care, and parking. Women incurring personal costs were more likely than those without personal costs to attend an urban facility (46% vs. 23%, p < 0.01) and be under the age of 50 (40% vs. 26%, p < 0.01). Overall, 61% of women listed convenience and 17% listed cost as a reason for choosing a mammography facility; 23% reported that cost might prevent them from obtaining a future mammogram. One third of women obtaining mammograms may be incurring personal costs. These personal costs should be considered in future cost-effectiveness analyses.

  12. Contrast-enhanced dual-energy digital subtraction mammography: optimization of the beam energy

    NASA Astrophysics Data System (ADS)

    Kwan, Alexander L. C.; Boone, John M.; Le-Petross, Huong; Lindfors, Karen K.; Seibert, J. A.; Lewin, John M.

    2005-04-01

    The implementation of contrast-enhanced dual-energy digital subtraction mammography may lead to better identification of breast tumors, and thus provide a lower cost and more widely available alternative to breast MRI. This technique involves the acquisition of low- and high-energy images after the IV administration of iodinated contrast agent. In this study, the effect of the beam energy (kVp) was examined using the CNR2/dose metric, where CNR is the contrast-to-noise ratio and dose implies the mean glandular dose. The mean glandular dose was calculated using parameterized normalized glandular dose coefficients (DgN), which allowed the computation of the mean glandular dose for the modeled spectra considered in this study, coupled with incident kerma measurements. Optimization studies were performed using a dedicated cone-beam breast CT scanner designed and fabricated in our laboratory, with the system operating in stationary imaging mode. A flat tissue-equivalent phantom (7.5 cm in thickness) was placed at the isocenter of the scanner, and an air gap of 34.5 cm was used in lieu of a grid. Dilute iodine-based contrast agent was introduced into the phantoms using plastic vials. Data were acquired from 40 to 90 kVp at 10 kVp intervals. Due to the low mA available on the breast CT system, a large number of images (1000) were acquired in fluoroscopic mode, which allowed us to match the dose and noise properties for each kVp combinations by changing the number of images used for averaging. Preliminary results demonstrate that the best CNR2/dose is achieved with a 50 kVp low-energy image and a 90 kVp high-energy image. Consequently, radiation doses for contrast-enhanced mammography should be far lower than regular mammography. Since the spatial resolution requirements should also be lower than regular mammography, dual-energy contrast-enhanced mammography, when performed using the optimal technique factor, may indeed provide very similar diagnostic information as breast

  13. Changing patterns of microcalcification on screening mammography for prediction of breast cancer.

    PubMed

    Kim, Kwan Il; Lee, Kyung Hee; Kim, Tae Ryung; Chun, Yong Soon; Lee, Tae Hoon; Choi, Hye Young; Park, Heung Kyu

    2016-05-01

    The presence of microcalcification on mammography is one of the earliest signs in breast cancer detection. However, it is difficult to distinguish malignant calcifications from benign calcifications. The aim of this study is to evaluate correlation between changing patterns of microcalcification on screening mammography and malignant breast lesions. Medical records and diagnostic images of 67 women who had previously undergone at least two digital mammograms at least 6 months apart and underwent mammography-guided needle localization and surgical excision between 2011 and 2013 were retrospectively reviewed and analyzed. Breast cancer was detected in the surgical specimens of 20 patients (29.9 %). Annual change of extent of microcalcification on mammography showed statistically significant correlation with pathologic outcome (P = 0.023). The changing pattern of new appearance or increased extent of microcalcification on mammography had positive predictive value of 54.8 % for breast cancer, and it was a statistically significant predictor for breast cancer (P = 0.012). Shape or number change of microcalcification without increased extent had less accurate predictive value for breast cancer, particularly in women younger than 50 years (P < 0.001). This study showed that the pattern of increased extent of microcalcification on screening mammography was a significant predictor for breast cancer. We suggest that mammography-guided needle localization and surgical excision should be considered when increased extent of microcalcification is observed on screening mammography and closed follow-up without pathologic confirmation can be permitted if absence of extension of microcalcification was confirmed in women younger than 50 years.

  14. Clinical study of contrast-enhanced digital mammography and the evaluation of blood and lymphatic microvessel density

    PubMed Central

    Cruz-Bastida, Juan P; Rosado-Méndez, Iván M; Villaseñor-Navarro, Yolanda; Pérez-Ponce, Héctor; Galván, Héctor A; Trujillo-Zamudio, Flavio E; Sánchez-Suárez, Patricia; Benítez-Bribiesca, Luis

    2016-01-01

    Objective: To correlate image parameters in contrast-enhanced digital mammography (CEDM) with blood and lymphatic microvessel density (MVD). Methods: 18 Breast Imaging-Reporting and Data System (BI-RADS)-4 to BI-RADS-5 patients were subjected to CEDM. Craniocaudal views were acquired, two views (low and high energy) before iodine contrast medium (CM) injection and four views (high energy) 1–5 min afterwards. Processing included registration and two subtraction modalities, traditional single-energy temporal (high-energy) and “dual-energy temporal with a matrix”, proposed to improve lesion conspicuity. Images were calibrated into iodine thickness, and iodine uptake, contrast, time–intensity and time–contrast kinetic curves were quantified. Image indicators were compared with MVD evaluated by anti-CD105 and anti-podoplanin (D2-40) immunohistochemistry. Results: 11 lesions were cancerous and 7 were benign. CEDM subtraction strongly increased conspicuity of lesions enhanced by iodine uptake. A strong correlation was observed between lymphatic vessels and blood vessels; all benign lesions had <30 blood microvessels per field, and all cancers had more than this value. MVD showed no correlation with iodine uptake, nor with contrast. The most frequent curve was early uptake followed by plateau for uptake and contrast in benign and malignant lesions. The positive-predictive value of uptake dynamics was 73% and that of contrast was 64%. Conclusion: CEDM increased lesion visibility and showed additional features compared with conventional mammography. Lack of correlation between image parameters and MVD is probably due to tumour tissue heterogeneity, mammography projective nature and/or dependence of extracellular iodine irrigation on tissue composition. Advances in knowledge: Quantitative analysis of CEDM images was performed. Image parameters and MVD showed no correlation. Probably, this is indication of the complex dependence of CM perfusion on tumour

  15. Automated daily quality control analysis for mammography in a multi-unit imaging center.

    PubMed

    Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli

    2018-01-01

    Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.

  16. CMOS cassette for digital upgrade of film-based mammography systems

    NASA Astrophysics Data System (ADS)

    Baysal, Mehmet A.; Toker, Emre

    2006-03-01

    While full-field digital mammography (FFDM) technology is gaining clinical acceptance, the overwhelming majority (96%) of the installed base of mammography systems are conventional film-screen (FSM) systems. A high performance, and economical digital cassette based product to conveniently upgrade FSM systems to FFDM would accelerate the adoption of FFDM, and make the clinical and technical advantages of FFDM available to a larger population of women. The planned FFDM cassette is based on our commercial Digital Radiography (DR) cassette for 10 cm x 10 cm field-of-view spot imaging and specimen radiography, utilizing a 150 micron columnar CsI(Tl) scintillator and 48 micron active-pixel CMOS sensor modules. Unlike a Computer Radiography (CR) cassette, which requires an external digitizer, our DR cassette transfers acquired images to a display workstation within approximately 5 seconds of exposure, greatly enhancing patient flow. We will present the physical performance of our prototype system against other FFDM systems in clinical use today, using established objective criteria such as the Modulation Transfer Function (MTF), Detective Quantum Efficiency (DQE), and subjective criteria, such as a contrast-detail (CD-MAM) observer performance study. Driven by the strong demand from the computer industry, CMOS technology is one of the lowest cost, and the most readily accessible technologies available for FFDM today. Recent popular use of CMOS imagers in high-end consumer cameras have also resulted in significant advances in the imaging performance of CMOS sensors against rivaling CCD sensors. This study promises to take advantage of these unique features to develop the first CMOS based FFDM upgrade cassette.

  17. Can tailored interventions increase mammography use among HMO women?

    PubMed

    Lipkus, I M; Rimer, B K; Halabi, S; Strigo, T S

    2000-01-01

    Telephone counseling and tailored print communications have emerged as promising methods for promoting mammography screening. However, there has been little research testing, within the same randomized field trial, of the efficacy of these two methods compared to a high-quality usual care system for enhancing screening. This study addressed the question: Compared to usual care, is tailored telephone counseling more effective than tailored print materials for promoting mammography screening? Three-year randomized field trial. One thousand ninety-nine women aged 50 and older recruited from a health maintenance organization in North Carolina. Women were randomized to 1 of 3 groups: (1) usual care, (2) tailored print communications, and (3) tailored telephone counseling. Adherence to mammography screening based on self-reports obtained during 1995, 1996, and 1997. Compared to usual care alone, telephone counseling promoted a significantly higher proportion of women having mammograms on schedule (71% vs 61%) than did tailored print (67% vs 61%) but only after the first year of intervention (during 1996). Furthermore, compared to usual care, telephone counseling was more effective than tailored print materials at promoting being on schedule with screening during 1996 and 1997 among women who were off-schedule during the previous year. The effects of the intervention were most pronounced after the first intervention. Compared to usual care, telephone counseling seemed particularly effective at promoting change among nonadherent women, the group for whom the intervention was developed. These results suggest that telephone counseling, rather than tailored print, might be the preferred first-line intervention for getting nonadherent women on schedule for mammography screening. Many questions would have to be answered about why the tailored print intervention was not more powerful. Nevertheless, it is clear that additional interventions will be needed to maintain women

  18. [Mammography screening of breast cancer in Tunisia. Results of first experience].

    PubMed

    Kribi, Lilia; Sellami, Dorra; el Amri, Aïda; Mnif, Nejla; Ellouze, Thouraya; Chebbi, Ali; Ben Romdhane, Khaled; Hamza, Radhi

    2003-01-01

    This article reports the results of a mammography screening program of breast cancer, realized in the department of Radiology, Charles Nicolle hospital. A free screening mammography with two incidences was offered to women aged from 40 to 70 years old. 2200 mammographies were realized from May 1995 till July 1997. Women having a positive test benefited of a diagnostic explorations in the same unity. The positive test rate was 24%. Predictive positive value was 31%. This program allowed to detect 10 subclinical cancers, corresponding to a rate of detection of 4.5 cancers for 1000 women. This program is a first experience which demonstrated the feasibility of the mammography screening to wide scale and allowed the medical and paramedical team to acquire an experience.

  19. Study of signal-to-noise ratio in digital mammography

    NASA Astrophysics Data System (ADS)

    Kato, Yuri; Fujita, Naotoshi; Kodera, Yoshie

    2009-02-01

    Mammography techniques have recently advanced from those using analog systems (the screen-film system) to those using digital systems; for example, computed radiography (CR) and flat-panel detectors (FPDs) are nowadays used in mammography. Further, phase contrast mammography (PCM)-a digital technique by which images with a magnification of 1.75× can be obtained-is now available in the market. We studied the effect of the air gap in PCM and evaluated the effectiveness of an antiscatter x-ray grid in conventional mammography (CM) by measuring the scatter fraction ratio (SFR) and relative signal-to-noise ratio (rSNR) and comparing them between PCM and the digital CM. The results indicated that the SFRs for the CM images obtained with a grid were the lowest and that these ratios were almost the same as those for the PCM images. In contrast, the rSNRs for the PCM images were the highest, which means that the scattering of x-rays was sufficiently reduced by the air gap without the loss of primary x-rays.

  20. Assessment of Mammography Experiences and Satisfaction among American Indian/Alaska Native Women

    PubMed Central

    Ndikum-Moffor, Florence M.; Braiuca, Stacy; Daley, Christine Makosky; Gajewski, Byron J.; Engelman, Kimberly K.

    2013-01-01

    BACKGROUND American Indian/Alaska Native (AI/AN) women have lower breast cancer (BCA) screening and 5-year survival rates than non-Hispanic Whites. Understanding reasons for low screening rates is important to combat later stage diagnoses. The purpose of this study was to assess mammography experiences and satisfaction among AI/AN women. METHODS Nine focus groups were held with rural (N=15) and urban (N=38) AI/AN women 40 years and older in Kansas and Kansas City, Missouri, living both near and far from Indian Health Service (IHS) and tribal facilities, to examine experiences and satisfaction with mammography. Transcripts were coded and themes identified using a community-based participatory research approach. FINDINGS Themes were classified under knowledge, communication, and awareness of breast cancer, barriers to mammography, mammogram facility size, impressions of mammogram technologist, motivations to getting a mammogram, and how to improve the mammogram experience. Participants had knowledge of prevention, but described cultural reasons for not discussing it and described better experiences in smaller facilities. Participants indicated having a mammogram technologist who was friendly, knowledgeable, respectful, competent, and explained the test was a determining factor in satisfaction. Other factors included family history, physician recommendation, and financial incentives. Barriers included transportation, cost, perceptions of prejudice, and time constraints. Participants on reservations or near IHS facilities preferred IHS over mainstream providers. Suggestions for improvement included caring technologists, better machines with less discomfort, and education. CONCLUSIONS Interventions to enhance the professionalism, empathy, and cultural awareness of mammogram technologists, reduce barriers, and provide positive expectations and incentives could improve satisfaction and compliance with screening mammography. PMID:24183414

  1. Feasibility study for positron emission mammography.

    PubMed

    Thompson, C J; Murthy, K; Weinberg, I N; Mako, F

    1994-04-01

    A feasibility study is presented for a small, low-cost, dedicated device for positron emission mammography. Two detector arrays above and below the breast would be placed in a conventional mammography unit. These detectors are sensitive to positron annihilation radiation, and are connected to a coincidence circuit and a multiplane image memory. Images of the distribution of positron-emitting isotope are obtained in real time by incrementing the memory location at the intersection of each line of response. Monte Carlo simulations of a breast phantom are compared with actual scans of this phantom in a conventional PET scanner. The simulations and experimental data are used to predict the performance of the proposed system. Spatial resolution experiments using very narrow bismuth germanate BGO crystals suggest that spatial resolutions of about 2 mm should be possible. The efficiency of the proposed device is about ten times that of a conventional brain scanner. The scatter fraction is greater, but the scattered radiation has a very flat distribution. By designing the device to fit in an existing mammography unit, conventional mammograms can be taken after the injection of the radio-pharmaceutical allowing exact registration of the emission and conventional mammographic images.

  2. Radiation-Induced Breast Cancer Incidence and Mortality From Digital Mammography Screening: A Modeling Study.

    PubMed

    Miglioretti, Diana L; Lange, Jane; van den Broek, Jeroen J; Lee, Christoph I; van Ravesteyn, Nicolien T; Ritley, Dominique; Kerlikowske, Karla; Fenton, Joshua J; Melnikow, Joy; de Koning, Harry J; Hubbard, Rebecca A

    2016-02-16

    Estimates of risk for radiation-induced breast cancer from mammography screening have not considered variation in dose exposure or diagnostic work-up after abnormal screening results. To estimate distributions of radiation-induced breast cancer incidence and mortality from digital mammography screening while considering exposure from screening and diagnostic mammography and dose variation among women. 2 simulation-modeling approaches. U.S. population. Women aged 40 to 74 years. Annual or biennial digital mammography screening from age 40, 45, or 50 years until age 74 years. Lifetime breast cancer deaths averted (benefits) and radiation-induced breast cancer incidence and mortality (harms) per 100,000 women screened. Annual screening of 100,000 women aged 40 to 74 years was projected to induce 125 breast cancer cases (95% CI, 88 to 178) leading to 16 deaths (CI, 11 to 23), relative to 968 breast cancer deaths averted by early detection from screening. Women exposed at the 95th percentile were projected to develop 246 cases of radiation-induced breast cancer leading to 32 deaths per 100,000 women. Women with large breasts requiring extra views for complete examination (8% of population) were projected to have greater radiation-induced breast cancer risk (266 cancer cases and 35 deaths per 100,000 women) than other women (113 cancer cases and 15 deaths per 100,000 women). Biennial screening starting at age 50 years reduced risk for radiation-induced cancer 5-fold. Life-years lost from radiation-induced breast cancer could not be estimated. Radiation-induced breast cancer incidence and mortality from digital mammography screening are affected by dose variability from screening, resultant diagnostic work-up, initiation age, and screening frequency. Women with large breasts may have a greater risk for radiation-induced breast cancer. Agency for Healthcare Research and Quality, U.S. Preventive Services Task Force, National Cancer Institute.

  3. Mammography Screening Trends: The Perspective of African American Women Born Pre/Post World War II

    PubMed Central

    Williams, Karen Patricia; Mabiso, Athur; Lo, Yun-Jia; Penner, Louis A.

    2013-01-01

    Researchers have traditionally combined aging women (aged ≥50 years) when reporting their mammography use. This may inadvertently mask important cohort effects in mammography use, which are likely to result from distinct personal life experiences and generational differences. Using the Health and Retirement Study samples of 1998, 2000, and 2004, we examined cohort differences in mammography use between African American women born before 1946 (non–baby boomers) and those born in 1946 to 1953 (baby boomers). Between 1998 and 2004, screening rates for non–baby boomers declined, while those for baby boomers remained relatively steady. Hierarchical linear modeling (HLM) analyses suggest that while screening rates decreased with age (OR, 0.957; 95% CI, 0.947–0.968) cohort effects may have partially reversed the age effect, with non–baby boomers having an increased likelihood of receiving a mammogram compared to baby boomers (OR, 1.697; 95% CI, 1.278–2.254). Because African American women are diagnosed at later stages of breast cancer, documentation of cohort differences in mammography use among older African American women is important as health care professionals design intervention programs that are maximally effective for women from different cohorts. This is particularly critical as more African American women in the baby boomer cohort become part of the aging population. PMID:20575209

  4. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme.

    PubMed

    Lobbes, Marc B I; Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C; Nelemans, Patty J; van Roozendaal, Lori; Smidt, Marjolein L; Heuts, Esther; Wildberger, Joachim E

    2014-07-01

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0% (+3.1%), specificity to 87.7% (+45.7%), PPV to 76.2% (+36.5%) and NPV to 100.0% (+2.9%) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p < 0.0001). A similar trend was observed in the ROC curve. For conventional mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p < 0.0001). In addition, good agreement between tumour diameters measured using CESM, breast MRI and histopathology was observed. CESM increases diagnostic performance of conventional mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. • CESM is feasible in the workflow of referrals from routine breast screening. • CESM is superior to mammography, even in low disease prevalence populations. • CESM has an extremely high negative predictive value for breast cancer. • CESM is comparable to MRI in assessment of breast cancer extent. • CESM is comparable to histopathology in assessment of breast cancer extent.

  5. Beyond the mammography debate: a moderate perspective.

    PubMed

    Kaniklidis, C

    2015-06-01

    After some decades of contention, one can almost despair and conclude that (paraphrasing) "the mammography debate you will have with you always." Against that sentiment, in this review I argue, after reflecting on some of the major themes of this long-standing debate, that we must begin to move beyond the narrow borders of claim and counterclaim to seek consensus on what the balance of methodologically sound and critically appraised evidence demonstrates, and also to find overlooked underlying convergences; after acknowledging the reality of some residual and non-trivial harms from mammography, to promote effective strategies for harm mitigation; and to encourage deployment of new screening modalities that will render many of the issues and concerns in the debate obsolete. To these ends, I provide a sketch of what this looking forward and beyond the current debate might look like, leveraging advantages from abbreviated breast magnetic resonance imaging technologies (such as the ultrafast and twist protocols) and from digital breast tomosynthesis-also known as three-dimensional mammography. I also locate the debate within the broader context of mammography in the real world as it plays out not for the disputants, but for the stakeholders themselves: the screening-eligible patients and the physicians in the front lines who are charged with enabling both the acts of screening and the facts of screening at their maximally objective and patient-accessible levels to facilitate informed decisions.

  6. Beyond the mammography debate: a moderate perspective

    PubMed Central

    Kaniklidis, C

    2015-01-01

    After some decades of contention, one can almost despair and conclude that (paraphrasing) “the mammography debate you will have with you always.” Against that sentiment, in this review I argue, after reflecting on some of the major themes of this long-standing debate, that we must begin to move beyond the narrow borders of claim and counterclaim to seek consensus on what the balance of methodologically sound and critically appraised evidence demonstrates, and also to find overlooked underlying convergences; after acknowledging the reality of some residual and non-trivial harms from mammography, to promote effective strategies for harm mitigation; and to encourage deployment of new screening modalities that will render many of the issues and concerns in the debate obsolete. To these ends, I provide a sketch of what this looking forward and beyond the current debate might look like, leveraging advantages from abbreviated breast magnetic resonance imaging technologies (such as the ultrafast and twist protocols) and from digital breast tomosynthesis—also known as three-dimensional mammography. I also locate the debate within the broader context of mammography in the real world as it plays out not for the disputants, but for the stakeholders themselves: the screening-eligible patients and the physicians in the front lines who are charged with enabling both the acts of screening and the facts of screening at their maximally objective and patient-accessible levels to facilitate informed decisions. PMID:26089721

  7. Ditching the Disc: The Effects of Cloud-Based Image Sharing on Department Efficiency and Report Turnaround Times in Mammography.

    PubMed

    Morgan, Matthew B; Young, Elizabeth; Harada, Scott; Winkler, Nicole; Riegert, Joanna; Jones, Tony; Hu, Nan; Stein, Matthew

    2017-12-01

    In screening mammography, accessing prior examination images is crucial for accurate diagnosis and avoiding false-positives. When women visit multiple institutions for their screens, these "outside" examinations must be retrieved for comparison. Traditionally, prior images are obtained by faxing requests to other institutions and waiting for standard mail (film or CD-ROM), which can greatly delay report turnaround times. Recently, advancements in cloud-based image transfer technology have opened up more efficient options for examination transfer between institutions. The objective of this study was to evaluate the effect of cloud-based image transfer on mammography department workflow, time required to obtain prior images, and report turnaround times. Sixty screening examinations requiring prior images were placed into two groups (30 each). The control group used the standard institutional protocol for requesting prior images: faxing requests and waiting for mailed examinations. The experimental group used a cloud-based transfer for both requesting and receiving examinations. The mean number of days between examination request and examination receipt was measured for both groups and compared. The mean number of days from examination request to receipt was 6.08 days (SD 3.50) in the control group compared with 3.16 days (SD 3.95) in the experimental group. Using a cloud-based image transfer to obtain prior mammograms resulted in an average reduction of 2.92 days (P = .0361; 95% confidence interval 0.20-5.65) between examination request and receipt. This improvement in system efficiency is relevant for interpreting radiologists working to improve reporting times and for patients anxious to receive their mammography results. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  8. Computer Aided Detection (CAD) Systems for Mammography and the Use of GRID in Medicine

    NASA Astrophysics Data System (ADS)

    Lauria, Adele

    It is well known that the most effective way to defeat breast cancer is early detection, as surgery and medical therapies are more efficient when the disease is diagnosed at an early stage. The principal diagnostic technique for breast cancer detection is X-ray mammography. Screening programs have been introduced in many European countries to invite women to have periodic radiological breast examinations. In such screenings, radiologists are often required to examine large numbers of mammograms with a double reading, that is, two radiologists examine the images independently and then compare their results. In this way an increment in sensitivity (the rate of correctly identified images with a lesion) of up to 15% is obtained.1,2 In most radiological centres, it is a rarity to find two radiologists to examine each report. In recent years different Computer Aided Detection (CAD) systems have been developed as a support to radiologists working in mammography: one may hope that the "second opinion" provided by CAD might represent a lower cost alternative to improve the diagnosis. At present, four CAD systems have obtained the FDA approval in the USA. † Studies3,4 show an increment in sensitivity when CAD systems are used. Freer and Ulissey in 2001 5 demonstrated that the use of a commercial CAD system (ImageChecker M1000, R2 Technology) increases the number of cancers detected up to 19.5% with little increment in recall rate. Ciatto et al.,5 in a study simulating a double reading with a commercial CAD system (SecondLook‡), showed a moderate increment in sensitivity while reducing specificity (the rate of correctly identified images without a lesion). Notwithstanding these optimistic results, there is an ongoing debate to define the advantages of the use of CAD as second reader: the main limits underlined, e.g., by Nishikawa6 are that retrospective studies are considered much too optimistic and that clinical studies must be performed to demonstrate a statistically

  9. Socio-demographic correlates of participation in mammography: a survey among women aged between 35- 69 in Tehran, Iran.

    PubMed

    Samah, Asnarulkhadi Abu; Ahmadian, Maryam

    2012-01-01

    The rates of breast cancer have increased over the past two decades, and this raises concern about physical, psychological and social well-being of women with breast cancer. Further, few women really want to do breast cancer screening. We here investigated the socio-demographic correlates of mammography participation among 400 asymptomatic Iranian women aged between 35 and 69. A cross-sectional survey was conducted at the four outpatient clinics of general hospitals in Tehran during the period from July through October, 2009. Bi-variate analyses and multi-variate binary logistic regression were employed to find the socio- demographic predictors of mammography utilization among participants. The rate of mammography participation was 21.5% and relatively high because of access to general hospital services. More women who had undergone mammography were graduates from university or college, had full-time or part-time employment, were insured whether public or private, reported a positive family history of breast cancer, and were in the middle income level (P <0.01).The largest number of participating women was in the age range of 41 to 50 years. The results of multivariate logistic regression further showed that education (95%CI: 0.131-0.622), monthly income (95%CI: 0.038-0.945), and family history of breast cancer (95%CI: 1.97-9.28) were significantly associated (all P <0.05)with mammography participation. The most important issue for a successful screening program is participation. Using a random sample, this study found that the potential predictor variables of mammography participation included a higher education level, a middle income level, and a positive family history of breast cancer for Iranian women after adjusting for all other demographic variables in the model.

  10. Outcomes of a Structured Education Intervention for Latinas Concerning Breast Cancer and Mammography

    ERIC Educational Resources Information Center

    Laughman, Anna Bawtinhimer; Boselli, Danielle; Love, Magbis; Steuerwald, Nury; Symanowski, James; Blackley, Kris; Wheeler, Mellisa; Arevalo, Gustavo; Carrizosa, Daniel; Raghavan, Derek

    2017-01-01

    Objective: This study examined the utility of living room and church-based small group educational sessions on breast cancer and mammography, for under-served Latinas in North Carolina, USA. Design: Non-randomised, single arm design. Setting: A total of 329 self-selected Latinas participated in 31 small group educational classes in church and home…

  11. Image quality, threshold contrast and mean glandular dose in CR mammography

    NASA Astrophysics Data System (ADS)

    Jakubiak, R. R.; Gamba, H. R.; Neves, E. B.; Peixoto, J. E.

    2013-09-01

    In many countries, computed radiography (CR) systems represent the majority of equipment used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 and 75 mm. Initially, clinical images of 67 patients (group 1) were analyzed by three experienced radiologists, reporting about anatomical structures, noise and contrast in low and high pixel value areas, and image sharpness and contrast. Exposure parameters (kV, mAs and target/filter combination) used in the examinations of these patients were reproduced to determine the contrast-to-noise ratio (CNR) and mean glandular dose (MGD). The parameters were also used to radiograph a CDMAM (version 3.4) phantom (Artinis Medical Systems, The Netherlands) for image threshold contrast evaluation. After that, different breast thicknesses were simulated with polymethylmethacrylate layers and various sets of exposure parameters were used in order to determine optimal radiographic parameters. For each simulated breast thickness, optimal beam quality was defined as giving a target CNR to reach the threshold contrast of CDMAM images for acceptable MGD. These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. Using optimized exposure parameters, clinical images of 63 patients (group 2) were evaluated as described above. Threshold contrast, CNR and MGD for such exposure parameters were also determined. Results showed that the proposed optimization method was effective for all breast thicknesses studied in phantoms. The best result was found for breasts of 75 mm. While in group 1 there was no detection of the 0.1 mm critical diameter detail with threshold contrast below 23%, after the optimization, detection occurred in 47.6% of the images. There was also an average MGD reduction of 7.5%. The clinical image quality criteria were attended in 91.7% for all breast thicknesses evaluated in both

  12. Optimizing Imaging Instruments for Emission Mammography

    NASA Astrophysics Data System (ADS)

    Weinberg, Irving N.

    1996-05-01

    Clinical studies have demonstrated that radiotracer methods can noninvasively detect breast cancers in vivo(L.P. Adler, J.P.Crowe, N.K. Al-Kaisis, et al, Radiology 187,743-750 (1993)) (I. Khalkhali, I. Mena, E. Jouanne, et al, J. Am. Coll. Surg. 178, 491-497 (1994)). Due to spatial resolution and count efficiency considerations, users of conventional nuclear medicine instruments have had difficulty in detecting subcentimeter cancers. This limitation is unfortunate, since cancer therapy is generally most efficacious when tumor diameter at detection is less than a centimeter. A more subtle limitation of conventional nuclear medicine imaging instruments is that they are poorly suited to guiding interventions. With the assistance of C.J. Thompson from McGill University, and the CEBAF Detector Physics Group, we have explored the possibility of configuring detectors for nuclear medicine imaging devices into geometries that resemble conventional x-ray mammography cameras(I.N. Weinberg, U.S.Patent 5,252,830 (1993)). Phantom and pilot clinical studies suggest that applying breast compression within such geometries may offer several advantages(C.J. Thompson, K. Murthy, I.N. Weinberg, et al, Med. Physics 21, 259-538 (1994)): For coincident detection of positron emitters, efficiency and spatial resolution are improved by bringing the detectors very close to the source (the breast tumor). For single-photon detection, attenuation due to overlying tissue is reduced. Since, for a high-efficiency collimator, spatial resolution worsens with increasing source to collimator distance, adoption of compression allows more efficient collimators to be employed. Economics are favorable in that detectors can be deployed in the region of interest, rather than around the entire body, and that such detectors can be mounted in conventional mammographic gantries. The application of conventional mammographic geometry promises to assist physicians in conducting radiotracer-guided biopsies, and in

  13. [Programs of early detection of breast cancer and access of mammography in Spain].

    PubMed

    Luengo, S; Azcona, B; Lázaro, P; Madero, R

    1997-05-24

    We studied availability to mammography among Spanish women aged 40 to 70 years, variation in use of the mammography by autonomous community, and the situation and importance of breast cancer screening programs among other factors, in the access to mammography. A cross-sectional population survey was conducted in 1994 in a sample of 3,218 women. A questionnaire was used to collect data on the variable access (receipt of at least one mammogram in the last 2 years) as well as different access-related variables. Information on breast cancer screening programs was collected by contacting the responsible institutions. We considered that a program had total coverage if it included all the municipalities in the province and partial if it did not include all municipalities. Twenty-eight percent of women had performed a mammogram. This proportion varied among autonomous communities (AACC) from 11.5 to 73.8%. Breast cancer screening programs existed in 8 AACC. The multivariant analysis revealed an association between access to mammography and the existence of a screening program, especially when the later had total coverage (OR = 7.64; 95% CI = 5.24-11.10). An association was also found between access to mammography and physician-related factors, place of residence and attitudes of women toward mammography. Less than one third of women aged 40-70 have performed a mammography in the last 2 years, and this proportion varies among AACC. Gynecologist visits and the existence of breast cancer screening programs are fundamental factors in the access to mammography in Spain.

  14. Cost effectiveness of mammography screening for Chinese women.

    PubMed

    Wong, Irene O L; Kuntz, Karen M; Cowling, Benjamin J; Lam, Cindy L K; Leung, Gabriel M

    2007-08-15

    Although the cost effectiveness of screening mammography in most western developed populations has been accepted, it may not apply to Chinese women, who have a much lower breast cancer incidence. The authors estimated the cost effectiveness of biennial mammography in Hong Kong Chinese women to inform evidence-based screening policies. For the current study, a state-transition Markov model was developed to simulate mammography screening, breast cancer diagnosis, and treatment in a hypothetical cohort of Chinese women. The benefit of mammography was modeled by assuming a stage shift, in which cancers in screened women were more likely to be diagnosed at an earlier disease stage. The authors compared costs, quality-adjusted life years (QALYs) saved, and life years saved (LYS) for 5 screening strategies. Biennial screening resulted in a gain in life expectancy ranging from 4.3 days to 9.4 days compared with no screening at an incremental cost of from US $1,166 to US $2,425 per woman. The least costly, nondominated screening option was screening from ages 40 years to 69 years, with an incremental cost-effectiveness ratio (ICER) of US $61,600 per QALY saved or US $64,400 per LYS compared with no screening. In probabilistic sensitivity analyses, the probability of the ICER being below a threshold of US $50,000 per QALY (LYS) was 15.3% (14.6%). The current results suggested that mammography for Hong Kong Chinese women currently may not be cost effective based on the arbitrary threshold of US $50,000 per QALY. However, clinicians must remain vigilant and periodically should revisit the question of population screening: Disease rates in China have been increasing because of westernization and socioeconomic development.

  15. Mammography screening in six diverse communities in Chicago--a population study.

    PubMed

    Whitman, Steve; Shah, Ami M; Silva, Abigail; Ansell, David

    2007-01-01

    Despite the fact that recent studies suggest a narrowing in access to mammography, Black women are much more likely to die from breast cancer than White women. Data at the community level regarding mammography screening can help explain health disparities and inform plans for improved screening efforts. In 2002-2003, a comprehensive household health survey in English or Spanish was conducted in six community areas with 1700 households. The module on mammography was based on a state-based nationwide health survey and included questions on frequency of mammography, repeat screenings, and several demographic variables. The proportion of women >or=40 years (n=482) who received a mammogram in the past 2 years ranged from 74% to 90% across the six communities. The community with the highest screening proportion was predominantly Mexican and included recent immigrants. The screening proportion in the poorest community area, which was all Black, was 77%. Women with health insurance, higher income, and more education were more likely to receive a mammogram. Proportions for women >or=50 years (n=286) were slightly higher but similar. Repeat screening, which is recommended, occurred at lower levels. Access to and utilization of mammography have grown in recent years so that even these vulnerable communities had screening proportions at or even higher than the national average and the Healthy People Year 2010 objective. Nonetheless, repeat screening sequences were lower and may require attention if mammography screening efforts are to have a greater impact on female breast cancer mortality.

  16. Mammography Prevalence within 2 Two Years (Age 40+) - Small Area Estimates

    Cancer.gov

    For mammography, a woman 40 years of age or older must have reported having at least one mammography in her life. Furthermore, she should have had the most recent one within the last two years by the time of interview.

  17. Developing a Mass Media Campaign to Promote Mammography Awareness in African American Women in the Nation's Capital.

    PubMed

    Wallington, Sherrie Flynt; Oppong, Bridget; Iddirisu, Marquita; Adams-Campbell, Lucile L

    2017-12-26

    This study developed and examined the reach and impact of a culturally appropriate mass media campaign pilot, designed to increase awareness about the importance of mammography screening and the available community mammography services for low-income African American women ages 40 and above. We conducted formative research using focus groups to inform campaign development, resulting in five emergent themes-good breast health, holistic views of healthiness, cancer fatalism, fear of mammogram machines, and mammogram affordability. The campaign targeted specific low-income African American communities in the District of Columbia via print ads in Metro stations and on buses, print ads in the Washington Informer, and online ads on a local TV network website. Data were collected before, during, and after campaign implementation to assess reach and impact. Reach was measured by number of impressions (number of people exposed to the campaign), while impact was assessed via online ad click-through rates, website use and referrals, and mammography center calls. The campaign was successful in reaching the target audience, with a total combined reach from all media of 9,479,386 impressions. In addition, the mammography center received significant increases in new website visitors (1482 during the campaign, compared to 24 during the preceding period) as well as 97 calls to the dedicated phone line. Further research involving a more long-term investment in terms of funding and campaign run time, coupled with a more robust evaluation, is needed to assess if culturally appropriate mass media campaigns can generate increased mammography screening rates and decrease breast-cancer-related mortality.

  18. Screening Mammography Utilization in Tennessee Women: The Association with Residence

    ERIC Educational Resources Information Center

    Brown, Kathleen C.; Fitzhugh, Eugene C.; Neutens, James J.; Klein, Diane A.

    2009-01-01

    Context: Approximately 70% of US women over age 40 report mammography screening within 2 years. However, rates are likely to vary by age, income, educational level, and residence. Purpose: To describe the prevalence of screening mammography and associated factors in women living in rural and urban areas of Tennessee. Methods: Using pooled data…

  19. Breast density in screening mammography in Indian population - Is it different from western population?

    PubMed

    Singh, Tulika; Khandelwal, Niranjan; Singla, Veenu; Kumar, Dileep; Gupta, Madhu; Singh, Gurpreet; Bal, Amanjit

    2018-05-01

    Mammography is the only method presently considered appropriate for mass screening of breast cancer. However, higher breast density was strongly associated with lower mammographic sensitivity. Breast density is also identified as independent and strongest risk factors for breast cancer. Studies have shown women with high breast density have four to six times increased risk of breast cancer as compare to women with fatty breast. It varies between different age group it generally decreases with increasing age in postmenopausal women and it can be different in different ethnic groups and people from different geographical areas. This study evaluates the breast density in Indian population and its relationship with the age. We reviewed of all screening mammography examinations performed from May 2012 to January 2015 at our institute PGIMER, Chandigarh, INDIA. Descriptive analyses were used to examine the association between age and breast density. A total of 6132 screening mammograms were performed. Each subgroup categorized by decade of age. There was a significant inverse relationship between age and breast density (P < .001). Twenty-two percent of patients between 40 and 49 years old had dense breasts. This percentage decreased to 9% of women in their 50s. Only 7% of women in their 60s and 8% of women in their 70s had dense breasts. This data has been compared with the Western study done in New York University (NYU) shows there is significant difference (P value <.05) in the breast density in Indian and Western population with more Indians having ACR Grade 1 and 2 and Western population having 2 and 3. We found an inverse relationship between patient age and mammographic breast density. However, there were a large proportion of young women who had lower grades of mammographic density which could potentially benefit from the use of routine screening mammography in this subgroup of patients. Moreover, the breast density of Indian population is less when compared to

  20. Contrast-enhanced spectral mammography improves diagnostic accuracy in the symptomatic setting.

    PubMed

    Tennant, S L; James, J J; Cornford, E J; Chen, Y; Burrell, H C; Hamilton, L J; Girio-Fragkoulakis, C

    2016-11-01

    To assess the diagnostic accuracy of contrast-enhanced spectral mammography (CESM), and gauge its "added value" in the symptomatic setting. A retrospective multi-reader review of 100 consecutive CESM examinations was performed. Anonymised low-energy (LE) images were reviewed and given a score for malignancy. At least 3 weeks later, the entire examination (LE and recombined images) was reviewed. Histopathology data were obtained for all cases. Differences in performance were assessed using receiver operator characteristic (ROC) analysis. Sensitivity, specificity, and lesion size (versus MRI or histopathology) differences were calculated. Seventy-three percent of cases were malignant at final histology, 27% were benign following standard triple assessment. ROC analysis showed improved overall performance of CESM over LE alone, with area under the curve of 0.93 versus 0.83 (p<0.025). CESM showed increased sensitivity (95% versus 84%, p<0.025) and specificity (81% versus 63%, p<0.025) compared to LE alone, with all five readers showing improved accuracy. Tumour size estimation at CESM was significantly more accurate than LE alone, the latter tending to undersize lesions. In 75% of cases, CESM was deemed a useful or significant aid to diagnosis. CESM provides immediately available, clinically useful information in the symptomatic clinic in patients with suspicious palpable abnormalities. Radiologist sensitivity, specificity, and size accuracy for breast cancer detection and staging are all improved using CESM as the primary mammographic investigation. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Gynecomastia: a common indication for mammography in men of all age.

    PubMed

    Capasso, Raffaella; Sica, A; D'Amora, M; Mostardi, Maurizio; Martella, Ilenia; Totaro, Marilina; Della Casa, Giovanni; Vallara, Manuela; Pesce, Antonella; Gatta, G; Cappabianca, S

    2016-07-28

    Gynecomastia (GM) is the most frequent cause of male breast-related signs and symptoms and represents also the most common indication for mammography (MX) in men. In this article, our 7-year long experience with MX in men suffering from GM is reviewed, and the mammographic features of GM are presented. MXs performed in male patients at our institution from January 2009 to January 2016 were retrospectively reviewed and patients with mammographic features of GM were selected. Informed consent was waived by the local institutional review board given the retrospective nature of the study. Mammograms were performed in both cranio-caudal (CC) and medio-lateral-oblique (MLO) views according to diagnostic needs. Clinical and pathologic data were obtained by review of patient charts. 37 males (aged between 13-79 years, mean 59 years) referred for MX at our institution because of palpable lump (31/37; 83.8%), breast enlargement (33/37; 89.2%), tenderness or pain (25/37; 67.6%). Of the 37 patients evaluated, 32 (86.5%) had true GM while 5 (13.5%) had pseudoGM. The evaluation of GM can be complex but a stepwise approach that starts with careful history taking and physical examination may obviate the need for extensive work-up. In this context, MX has been shown to be an accurate diagnostic tool for detecting GM and should be the first imaging examination to be performed in all clinically suspicious lesions referred for imaging.

  2. [Comparative study between film mammography and xeromammography; including specimen radiography].

    PubMed

    Maeda, M; Hayakawa, K; Okuno, Y; Torizuka, T; Mitsumori, M; Soga, T; Misaki, T; Dokou, S; Ito, K

    1990-10-01

    We retrospectively evaluated preoperative film- and xeromammography of 23 cases with breast cancers, and compared with postoperative specimen radiography to assess tumor delineation and microcalcification detectability. In tumor detection and margin delineation, film mammography was superior to xeromammography, and in microcalcification, film mammography was equal to xeromammography. These results had a effect on the diagnosis of breast cancers.

  3. The development of efficient X-ray conversion material for digital mammography

    NASA Astrophysics Data System (ADS)

    Oh, K.; Shin, J.; Kim, S.; Lee, Y.; Jeon, S.; Kim, J.; Nam, S.

    2012-02-01

    In this study, an experimental method based on theory is used to develop photoconductor that can replace the a-Se currently used as X-ray conversion layer in digital mammography. This is necessary because a-Se produced by the commercial fabrication method, of physical vapor deposition, has exhibited several problems when applied to digital mammography: instability due to crystallization and defect expansion due to high operating voltages, which is called the aging effect. Therefore, our work focused on developing a method of fabricating X-ray conversion films that do not suffer from crystallization and X-ray damage and optimizing the factors affecting the properties of the candidate photoconductors in order to acquire sufficient electrical signals to detect minute calcifications. The photoconductors were initially selected after the requirements for X-ray conversion materials, such as high atomic absorption, density, band-gap energy, work function, and resistivity, were examined. We selected HgI2, PbI2, and PbO because of their basic properties. Next, we experimentally investigated the performance of film samples fabricated by sedimentation and screen printing instead of physical vapor deposition. The structure of the X-ray conversion films (e.g., the thickness, electrodes, and blocking layer) were optimized for the application of a relatively low voltage to the X-ray conversion layer. The performance of the films were morphologically and electrically evaluated under mammography X-ray exposure conditions, and compared with those of a-Se films produced by physical vapor deposition. PbO appeared to be the most suitable alternative material because its electrical properties, such as the dark current, sensitivity, and signal-to-noise ratio (SNR), did not reveal the X-ray damage problem, and thus were maintained after repeated exposure to X-rays. Although PbO showed low sensitivity to X-ray exposure, its SNR was superior to that of the other materials, which is expected

  4. Postmortem validation of breast density using dual-energy mammography

    PubMed Central

    Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.

    2014-01-01

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer. PMID:25086548

  5. Postmortem validation of breast density using dual-energy mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molloi, Sabee, E-mail: symolloi@uci.edu; Ducote, Justin L.; Ding, Huanjun

    2014-08-15

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decompositionmore » was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.« less

  6. Size assessment of breast lesions by means of a computer-aided detection (CAD) system for magnetic resonance mammography.

    PubMed

    Levrini, G; Sghedoni, R; Mori, C; Botti, A; Vacondio, R; Nitrosi, A; Iori, M; Nicoli, F

    2011-10-01

    The aim of this study was to investigate the efficacy of a dedicated software tool for automated volume measurement of breast lesions in contrast-enhanced (CE) magnetic resonance mammography (MRM). The size of 52 breast lesions with a known histopathological diagnosis (three benign, 49 malignant) was automatically evaluated using different techniques. The volume of all lesions was measured automatically (AVM) from CE 3D MRM examinations by means of a computer-aided detection (CAD) system and compared with the size estimates based on maximum diameter measurement (MDM) on MRM, ultrasonography (US), mammography and histopathology. Compared with histopathology as the reference method, AVM understimated lesion size by 4% on average. This result was similar to MDM (3% understimation, not significantly different) but significantly better than US and mammographic lesion measurements (24% and 33% size underestimation, respectively). AVM is as accurate as MDM but faster. Both methods are more accurate for size assessment of breast lesions compared with US and mammography.

  7. Comparative effectiveness of mailed reminder letters on mammography screening compliance.

    PubMed

    Romaire, Melissa A; Bowles, Erin J Aiello; Anderson, Melissa L; Buist, Diana S M

    2012-08-01

    Reminder letters are effective at prompting women to schedule mammograms. Less well studied are reminders addressing multiple preventive service recommendations. We compared the effectiveness of a mammogram-specific reminder sent when a woman was due for a mammogram to a reminder letter addressing multiple preventive services and sent on a woman's birthday on mammography receipt. The study included 48,583 women 52-74 years enrolled in Group Health Cooperative, a health plan in Washington State. From 2005 to 2009, women were mailed 88,605 mammogram-specific or birthday letters. In this one group pretest-posttest study, we modeled the odds of obtaining a screening mammogram after receiving a letter by reminder type using logistic regression, controlling for demographic and healthcare use characteristics and stratifying by whether women were overdue or up-to-date with mammography at the mailing. Among women up-to-date with screening, birthday letters were negatively associated with mammography receipt compared to mammogram-specific letters (birthday letters with 1-2 recommendations: OR=0.73; 95% CI:0.68-0.79; 3 recommendations: OR=0.74; 95% CI:0.69-0.78; 4-8 recommendations: OR=0.62 95% CI:0.55-0.68) after. Among overdue women, birthday letters with 4-8 recommendations were negatively associated with mammography receipt. Transitioning from mammogram-specific reminder letters to multiple preventive service birthday letters was associated with decreased mammography receipt. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program

    PubMed Central

    Zuckerman, Samantha P.; Keller, Brad M.; Maidment, Andrew D. A.; Barufaldi, Bruno; Weinstein, Susan P.; Synnestvedt, Marie; McDonald, Elizabeth S.

    2016-01-01

    Purpose To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods This was an institutional review board–approved and HIPAA-compliant retrospective interpretation of prospectively acquired data with waiver of informed consent. Compared were recall rates, biopsy rates, cancer detection rates, and radiation dose for 15 571 women screened with digital mammography/DBT from October 1, 2011, to February 28, 2013, and 5366 women screened with s2D/DBT from January 7, 2015, to June 30, 2015. Two-sample z tests of equal proportions were used to determine statistical significance. Results Recall rate for s2D/DBT versus digital mammography/DBT was 7.1% versus 8.8%, respectively (P < .001). Biopsy rate for s2D/DBT versus digital mammography/DBT decreased (1.3% vs 2.0%, respectively; P = .001). There was no significant difference in cancer detection rate for s2D/DBT versus digital mammography/DBT (5.03 of 1000 vs 5.45 of 1000, respectively; P = .72). The average glandular dose was 39% lower in s2D/DBT versus digital mammography/DBT (4.88 mGy vs 7.97 mGy, respectively; P < .001). Conclusion Screening with s2D/DBT in a large urban practice resulted in similar outcomes compared with digital mammography/DBT imaging. Screening with s2D/DBT allowed for the benefits of DBT with a decrease in radiation dose compared with digital mammography/DBT. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on August 11, 2016. PMID:27467468

  9. Breast cancer screening and problem solving using mammography, ultrasound, and magnetic resonance imaging.

    PubMed

    Hooley, Regina J; Andrejeva, Liva; Scoutt, Leslie M

    2011-03-01

    Although mammography is the mainstay of early breast cancer detection, it has known limitations, particularly in women with dense breasts. As a result, additional imaging modalities, including ultrasound and contrast-enhanced magnetic resonance imaging, are also being used to supplement mammography in the early detection of occult breast cancer. This article reviews the indications and efficacy of mammography, ultrasound, and magnetic resonance imaging as both screening and diagnostic tools.

  10. Quality assurance in mammography: artifact analysis.

    PubMed

    Hogge, J P; Palmer, C H; Muller, C C; Little, S T; Smith, D C; Fatouros, P P; de Paredes, E S

    1999-01-01

    Evaluation of mammograms for artifacts is essential for mammographic quality assurance. A variety of mammographic artifacts (i.e., variations in mammographic density not caused by true attenuation differences) can occur and can create pseudolesions or mask true abnormalities. Many artifacts are readily identified, whereas others present a true diagnostic challenge. Factors that create artifacts may be related to the processor (eg, static, dirt or excessive developer buildup on the rollers, excessive roller pressure, damp film, scrapes and scratches, incomplete fixing, power failure, contaminated developer), the technologist (eg, improper film handling and loading, improper use of the mammography unit and related equipment, positioning and darkroom errors), the mammography unit (eg, failure of the collimation mirror to rotate, grid inhomogeneity, failure of the reciprocating grid to move, material in the tube housing, compression failure, improper alignment of the compression paddle with the Bucky tray, defective compression paddle), or the patient (e.g., motion, superimposed objects or substances [jewelry, body parts, clothing, hair, implanted medical devices, foreign bodies, substances on the skin]). Familiarity with the broad range of artifacts and the measures required to eliminate them is vital. Careful attention to darkroom cleanliness, care in film handling, regularly scheduled processor maintenance and chemical replenishment, daily quality assurance activities, and careful attention to detail during patient positioning and mammography can reduce or eliminate most mammographic artifacts.

  11. Position paper: recommendations for a digital mammography quality assurance program V4.0.

    PubMed

    Heggie, J C P; Barnes, P; Cartwright, L; Diffey, J; Tse, J; Herley, J; McLean, I D; Thomson, F J; Grewal, R K; Collins, L T

    2017-09-01

    In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation of digital mammography has been realised and it has become evident that existing screen-film protocols were not appropriate to assure the required image quality needed for reliable diagnosis or to address the new dose implications resulting from digital technology. In addition, the advantages and responsibilities inherent in teleradiology are most critical in mammography and also need to be addressed. The current document is the result of a review of current overseas practice and local experience in these areas. At this time the technology of digital imaging is undergoing significant development and there is still a lack of full international consensus about some of the detailed quality control (QC) tests that should be included in quality assurance (QA) programs. This document describes the current status in digital mammography QA and recommends test procedures that may be suitable in the Australasian environment. For completeness, this document also includes a review of the QA programs required for the various types of digital biopsy units used in mammography. In the future, international harmonisation of digital quality assurance in mammography and changes in the technology may require a review of this document. Version 2.0 represented the first of these updates and key changes related to image quality evaluation, ghost image evaluation and interpretation of signal to noise ratio measurements. In Version 3.0 some significant changes, made in light of further experience gained in testing digital mammography equipment were introduced. In Version 4.0, further changes have been made, most notably digital breast tomosynthesis (DBT) testing and QC have

  12. Knowledge, attitude and practice of mammography among women users of public health services.

    PubMed

    Marinho, Luiz Alberto Barcelos; Cecatti, José Guilherme; Osis, Maria José Duarte; Gurgel, Maria Salete Costa

    2008-04-01

    To evaluate knowledge, attitude and practice related to mammography among women users of local health services, identifying barriers to its performance. A total of 663 women were interviewed at 13 local health centers in a city of Southeastern Brazil, in 2001. Interviewees were randomly selected at each center and they were representative from different socioeconomic conditions. The number of interviewees at each center was proportional to monthly mean appointments. For data analysis, answers were described as knowledge, attitude, practice and their respective adequacies and then they were correlated with control variables through the chi-square test. Only 7.4% of the interviewees had adequate knowledge on mammography, while 97.1% of women had an adequate attitude. The same was seen for the practice of mammography that was adequate in 35.7% of the cases. The main barrier to mammography was lack of referral by physicians working at the health center (81.8%). There was an association between adequacy of attitude and five years or more of education and being married. There was also an association between adequacy of mammography practice and being employed and family income up to four minimum wages. Women users of local health services had no adequate knowledge and practice related to mammography despite having an adequate attitude about this exam.

  13. Moving beyond the Typologies of Managed Care: The Example of Health Plan Predictors of Screening Mammography

    PubMed Central

    Tye, Sherilyn; Phillips, Kathryn A; Liang, Su-Ying; Haas, Jennifer S

    2004-01-01

    Objectives To develop a framework of factors to characterize health plans, to identify how plan characteristics were measured in a national survey, and to apply our findings to an analysis of the predictors of screening mammography. Data Source The primary data were from the 1996 Medical Expenditure Panel Survey. Study Design Women ages 40+, with private insurance, and no history of breast cancer were included in the study (N=2,909). We used multivariate logistic regression to estimate mammography utilization in the past two years relative to health plan and demographic factors. Health plan measures included whether there is a defined provider network, whether coverage is restricted to a network, use of gatekeepers, level of cost containment, copayment and deductible amounts, coinsurance rate, and breadth of benefit coverage. Principal Findings We found no significant difference in reported mammography utilization using a dichotomous comparison of individuals enrolled in managed care versus indemnity plans. However, women in health plans with a defined provider network were more likely to report having received a mammogram in the past two years than those without networks (adjusted OR=1.21, 95 percent CI=1.07–1.36), and women in gatekeeper plans were more likely to report receiving mammography than those without gatekeepers (adjusted OR=1.18, 95 percent CI=1.03–1.36). Restricted out-of-network coverage, use of cost containment, enrollee cost sharing, and breadth of benefit coverage did not appear to affect mammography use. Conclusions It is important to examine the effect of individual health plan components on the utilization of health care, rather than use the traditional broader categorizations of managed versus nonmanaged care or simple health plan typologies. PMID:14965083

  14. Digital mammography--DQE versus optimized image quality in clinical environment: an on site study

    NASA Astrophysics Data System (ADS)

    Oberhofer, Nadia; Fracchetti, Alessandro; Springeth, Margareth; Moroder, Ehrenfried

    2010-04-01

    The intrinsic quality of the detection system of 7 different digital mammography units (5 direct radiography DR; 2 computed radiography CR), expressed by DQE, has been compared with their image quality/dose performances in clinical use. DQE measurements followed IEC 62220-1-2 using a tungsten test object for MTF determination. For image quality assessment two different methods have been applied: 1) measurement of contrast to noise ratio (CNR) according to the European guidelines and 2) contrast-detail (CD) evaluation. The latter was carried out with the phantom CDMAM ver. 3.4 and the commercial software CDMAM Analyser ver. 1.1 (both Artinis) for automated image analysis. The overall image quality index IQFinv proposed by the software has been validated. Correspondence between the two methods has been shown figuring out a linear correlation between CNR and IQFinv. All systems were optimized with respect to image quality and average glandular dose (AGD) within the constraints of automatic exposure control (AEC). For each equipment, a good image quality level was defined by means of CD analysis, and the corresponding CNR value considered as target value. The goal was to achieve for different PMMA-phantom thicknesses constant image quality, that means the CNR target value, at minimum dose. All DR systems exhibited higher DQE and significantly better image quality compared to CR systems. Generally switching, where available, to a target/filter combination with an x-ray spectrum of higher mean energy permitted dose savings at equal image quality. However, several systems did not allow to modify the AEC in order to apply optimal radiographic technique in clinical use. The best ratio image quality/dose was achieved by a unit with a-Se detector and W anode only recently available on the market.

  15. Characterization of scatter in digital mammography from physical measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leon, Stephanie M., E-mail: Stephanie.Leon@uth.tmc.edu; Wagner, Louis K.; Brateman, Libby F.

    2014-06-15

    Purpose: That scattered radiation negatively impacts the quality of medical radiographic imaging is well known. In mammography, even slight amounts of scatter reduce the high contrast required for subtle soft-tissue imaging. In current clinical mammography, image contrast is partially improved by use of an antiscatter grid. This form of scatter rejection comes with a sizeable dose penalty related to the concomitant elimination of valuable primary radiation. Digital mammography allows the use of image processing as a method of scatter correction that might avoid effects that negatively impact primary radiation, while potentially providing more contrast improvement than is currently possible withmore » a grid. For this approach to be feasible, a detailed characterization of the scatter is needed. Previous research has modeled scatter as a constant background that serves as a DC bias across the imaging surface. The goal of this study was to provide a more substantive data set for characterizing the spatially-variant features of scatter radiation at the image detector of modern mammography units. Methods: This data set was acquired from a model of the radiation beam as a matrix of very narrow rays or pencil beams. As each pencil beam penetrates tissue, the pencil widens in a predictable manner due to the production of scatter. The resultant spreading of the pencil beam at the detector surface can be characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were calculated from measurements obtained using the beam stop method. Two digital mammography units were utilized, and the SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and presence or absence of a grid. These values were then used to generate general equations allowing the SF and MRE to be calculated for any combination of the above parameters. Results: With a grid, the SF ranged from a minimum of about 0.05 to a maximum of about

  16. Evaluation of a Mammography Screening Decision Aid for Women Aged 75 and Older: Protocol for a Cluster-randomized Controlled Trial

    PubMed Central

    Schonberg, Mara A; Kistler, Christine E; Nekhlyudov, Larissa; Fagerlin, Angela; Davis, Roger B; Wee, Christina C; Marcantonio, Edward R; Lewis, Carmen L; Stanley, Whitney A; Crutchfield, Trisha M.; Hamel, Mary Beth

    2015-01-01

    Purpose There is insufficient evidence to recommend mammography for women >75 years. Guidelines recommend that older women be informed of the uncertainty of benefit and potential for harm, especially for women with short life expectancy. However, few older women are informed of harms of screening and many with short life expectancy are screened. Therefore, we aim to test whether a mammography screening decision aid (DA) for women >75 years affects their use of mammography, particularly for women with <10 year life expectancy. Methods/Design The DA is a self-administered pamphlet that includes information on screening outcomes, tailored information on breast cancer risk, health, life expectancy, and competing mortality risks, and includes a values clarification exercise. We are conducting a large cluster randomized controlled trial (RCT) of the DA with the primary care provider (PCP) as the unit of randomization to evaluate its efficacy. We plan to recruit 550 women 75-89 years from 100 PCPs to receive either the mammography DA or a pamphlet on home safety for older adults (control arm) before a visit with their PCP, depending on their PCP's randomization assignment. The primary outcome is receipt of mammography screening assessed through chart abstraction. Secondary outcomes include effect of the DA on older women's screening intentions, knowledge, and decisional conflict, and on documented discussions about mammography by their PCPs. We will recruit women from 5 Boston-based primary care practices (3 community-based internal medicine practices and 2 academic practices), and 2 North Carolina-based academic primary care practices. Discussion It is essential that we test the DA in a large RCT to determine if it is efficacious and to substantiate the need for broad translation into clinical practice. Our DA has the potential to improve health care utilization and care in a manner dictated by patient preferences. PMID:26229741

  17. MRI and mammography surveillance of women at increased risk for breast cancer: recommendations using an evidence-based approach.

    PubMed

    Granader, Elon J; Dwamena, Ben; Carlos, Ruth C

    2008-12-01

    To evaluate breast cancer screening with mammography and magnetic resonance imaging (MRI) in high-risk populations, including women with the BRCA mutation, using an evidence-based approach. The MEDLINE, PubMed, EBM Reviews, ACP Journal Club, Cochrane Database MEDSEARCH, and SCOPUS databases were accessed and searched for articles up to August 2007. Articles were collected using the following terms and medical subject headings (MeSH) that applied to the focused clinical question: "BRCA1" and "BRCA2" with "mammography," "MRI," "prevention," "screening," and "surveillance." References from retrieved articles were also used to identify relevant papers. Abstracts were screened and relevant papers retrieved. Retrieved papers were graded for quality. Summary performance measures were obtained by random effects modeling of study-specific performance estimates and standard errors derived from the multiple 2 x 2 tables. Additionally, studies meeting the Centre for Evidence-Based Medicine level 2b quality were reviewed. In women with an increased risk without the BRCA gene, cancer detection rates by MRI were 0.011 (95% confidence interval [CI] 0.003-0.019), by mammography 0.005 (95% CI 0.002-0.008), and by a combination of both, 0.012 (95% CI 0.004-0.020). False-positive rates by MRI, mammography, or a combination of both were 0.10 (95% CI 0.03-0.18), 0.05 (95% CI 0.03-0.06), and 0.14 (95% CI 0.04-0.24). In BRCA positive women, cancer detection rates by MRI were 0.027 (95% CI 0.015-0.040), by mammography 0.010 (95% CI 0.005-0.016), and by a combination of both 0.031 (95% CI 0.018-0.045). False-positive rates by MRI, mammography, or a combination of both were 0.10 (95% CI 0.01-0.19), 0.05 (95% CI 0.03-0.07), and 0.14 (95% CI 0.04-0.24), respectively. The data support an essential role for screening MRI in women with an increased risk for breast cancer.

  18. Monte Carlo generated conversion factors for the estimation of average glandular dose in contact and magnification mammography

    NASA Astrophysics Data System (ADS)

    Koutalonis, M.; Delis, H.; Spyrou, G.; Costaridou, L.; Tzanakos, G.; Panayiotakis, G.

    2006-11-01

    Magnification mammography is a special technique used in the cases where breast complaints are noted by a woman or when an abnormality is found in a screening mammogram. The carcinogenic risk in mammography is related to the dose deposited in the glandular tissue of the breast rather than the adipose, and average glandular dose (AGD) is the quantity taken into consideration during a mammographic examination. Direct measurement of the AGD is not feasible during clinical practice and thus, the incident air KERMA on the breast surface is used to estimate the glandular dose, with the help of proper conversion factors. Additional conversion factors adapted for magnification and tube voltage are calculated, using Monte Carlo simulation. The effect of magnification degree, tube voltage, various anode/filter material combinations and glandularity on AGD is also studied, considering partial breast irradiation. Results demonstrate that the estimation of AGD utilizing conversion factors depends on these parameters, while the omission of correction factors for magnification and tube voltage can lead to significant underestimation or overestimation of AGD. AGD was found to increase with filter material's k-absorption edge, anode material's k-emission edge, tube voltage and magnification. Decrease of the glandularity of the breast leads to higher AGD due to the increased penetrating ability of the photon beam in thick breasts with low glandularity.

  19. An Optometric Clinical Practicum Examination Model.

    ERIC Educational Resources Information Center

    Eskridge, Jess B.

    1979-01-01

    A practical clinical examination model for use by state board examiners in optometry is described including purpose, format, examination design, procedures, evaluation examples and administration. (JMF)

  20. Estimation of mean glandular dose for patients who undergo mammography and studying the factors affecting it

    NASA Astrophysics Data System (ADS)

    Barzanje, Sana L. N. H.; Harki, Edrees M. Tahir Nury

    2017-09-01

    The objective of this study was to determine mean glandular dose (MGD) during diagnostic mammography. This study was done in two hospitals in Hawler city in Kurdistan -region /Iraq, the exposure parameters kVp and mAs was recorded for 40 patients under go mammography. The MGD estimated by multiplied ESD with normalized glandular dose (Dn). The ESD measured indirectly by measuring output radiation mGy/mAs by using PalmRAD 907 as a suitable detector (Gigger detector).the results; shown that the mean and its standard deviation of MGD for Screen Film Mammography and Digital Mammography are (0.95±0.18)mGy and (0.99±0.26)mGy, respectively. And there is a significant difference between MGD for Screen Film Mammography and Digital Mammography views (p≤0. 05). Also the mean value and its standard deviation of MGD for screen film mammography is (0.96±0.21) for CC projection and (1.03±0.3) mGy for MLO projection, but mean value and its standard deviation evaluated of MGD for digital mammography is (0.92±0.17) mGy for CC projection and (0.98±0.2) mGy for MLO projection. As well as, the effect of kVp and mAs in MGD were studied, shows that in general as kVp and mAs increased the MGD increased accordingly in both of mammography systems.

  1. [Prevalence in the performance of mammographies in Spain: Analysis by Communities 2006-2014 and influencing factors].

    PubMed

    Carmona-Torres, Juan Manuel; Cobo-Cuenca, Ana Isabel; Martín-Espinosa, Noelia María; Piriz-Campos, Rosa María; Laredo-Aguilera, José Alberto; Rodríguez-Borrego, María Aurora

    2018-04-01

    To determine the frequency of the performance of mammography with preventive purpose of the screening of breast cancer in Spanish women, the evolution between the years 2006-2014, the sociodemographic profile of the women who undergo the mammography and to analyze the factors that influence in their adhesion. Transversal study. Spain. A total of 53.628 women over 15 years old that are surveyed in the National Health Survey in Spain 2006 and 2011/12 and the European Health Survey in Spain 2009 and 2014. The following variables were used: mammography, frequency of mammography performance and the reason for the realization, as well as sociodemographic variables. Social class was obtained from the last occupation of the main family supporter. A logistic regression analysis was performed with sociodemographic variables. The prevalence of mammography has been increasing from 2006 to 2014, and also for the reason that the participants had received a letter, they were telephoned or offered in their Health Center to undergo this test. There are significant differences in the performance of mammography in the different autonomous communities. Performing mammography has increased significantly from 2006 to 2014, although there are still differences between autonomous communities, with Ceuta and Melilla being the least percentage of performed mammography. The factors that are related to greater performed mammography are: higher educational level, higher social class, married civil status, Spanish nationality and age. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  2. A single issue program in an isolated area: mammography screening in Darwin, NT.

    PubMed

    McLean, M J; Condon, J R

    1999-08-01

    A process evaluation of the Northern Territory (NT) mammography program, NT Breast Screen (NTBS), during its initial 18 months of operation. The study was undertaken in Darwin, NT, from December 1994 to May 1996. Clinical outcomes were obtained by reviewing computerised and manual program records to determine waiting times for results, recall rates and cancer detection rates. Client satisfaction was assessed by a questionnaire sent to all women with normal results over a 12-week period. General practitioner satisfaction was assessed by a questionnaire sent to all general practitioners in the region who had one or more clients who had attended the service. During this time, 2,882 screening mammograms were performed; 98 women were recalled for assessment (3.4%). Breast cancer was detected in 10 women (3.5 per 1000 women screened). The program was well accepted by clients and general practitioners. Performance criteria were not met for waiting times for results. NTBS faced challenges because of its small and dispersed population, a lack of local radiologists with mammographic experience and the conflict with other pressing health issues, particularly in Aboriginal health. Despite these challenges, the program functioned effectively during its initial 18 months. Mammography screening programs in isolated areas can function effectively. The constraints encountered by NTBS are likely to apply to similar programs. Issues identified requiring further research are the psychological consequences of long waiting times for results, and the prioritisation of mammography for Aboriginal women.

  3. Performance Evaluation and Initial Clinical Test of the Positron Emission Mammography System (PEMi)

    NASA Astrophysics Data System (ADS)

    Li, Lin; Gu, Xiao-Yue; Li, Dao-Wu; Huang, Xian-Chao; Chai, Pei; Feng, Bao-Tong; Wang, Pei-Lin; Yun, Ming-Kai; Dai, Dong; Zhang, Zhi-Ming; Yin, Peng-Fei; Xu, Wen-Gui; Wei, Long

    2015-10-01

    A new polygon positron emission mammography imaging system (PEMi) was developed in 2009 by the Institute of High Energy Physics, Chinese Academy of Sciences. PEMi is constructed in a polygon structure with lutetium yttrium orthosilicate crystal arrays mounted on a position-sensitive photomultiplier. The system consists of 64 blocks and each block is arranged in 16 ×16 crystal arrays with a pixel size of 1.9 ×1.9 ×15 mm. The diameter of the detector ring is 166 mm, and the axial length is 128 mm. The transaxial field of view of PEMi is 110 mm. The goal of the initial study was to test PEMi's performance and the clinical imaging ability with a small group of selected subjects. The detectors have a measured intrinsic spatial resolution averaging 1.67 mm. The axial and tangential resolution remained under 2.5-mm full width at half maximum within the central 5-cm diameter of the field of view. The hot rods with a diameter of 1.7 mm can be clearly identified, and the structure of the region containing 1.35-mm diameter rods can also be observed. Using a 6-ns coincidence timing window and a 360 660-keV energy window, the peak sensitivity of the tomograph is 6.88%. The noise-equivalent count rate peak is 110 766 cps for a breast-like cylindrical phantom of 100 mm in diameter at an activity concentration of 0.03 MBq/cc. The recovery coefficients ranged from 0.21 to 0.85 for rods between 1 mm and 5 mm in the image-quality phantom. The reconstructed image resolution achieved an improvement compared with whole-body positron emission tomography (PET), which might reduce the lower threshold on detectable lesion size. Example patient images demonstrate that PEMi is clinically feasible. And more detailed structure information was obtained with PEMi than with the whole-body PET imaging.

  4. Willingness to pay for mammography: item development and testing among five ethnic groups

    PubMed Central

    Hu, Teh-wei; Dueñas, Grace V.; Pasick, Rena J.

    2010-01-01

    The goal of this study was to develop a willingness to pay (WTP) question for mammography that is appropriate for low income, ethnically-diverse women. Through qualitative research with 50 low income women of five ethnic groups we developed both a WTP question and a willingness to travel question (WTT). After being refined through interviews with 41 women, these questions were pilot tested on a random sample of 52 low income, ethnically-diverse women in the San Francisco area. Results show that the concepts underlying WTP and WTT were culturally appropriate to the five ethnicities in this study. Analyses generally confirm the validity of the WTP and WTT questions. As expected, WTP was associated with household income, perceived risk of cancer, and knowledge that one needs a mammogram even after a clinical breast examination. Despite the small samples, WTP varied among the ethnic groups. Additionally, WTT was moderately correlated with the natural log of WTP (r = 0.58, P < 0.001). These questions are now in use in a larger clinical trial and future analyses will explore willingness to pay and willingness to travel within and across the ethnic groups. PMID:11014787

  5. Shapelet analysis of pupil dilation for modeling visuo-cognitive behavior in screening mammography

    NASA Astrophysics Data System (ADS)

    Alamudun, Folami; Yoon, Hong-Jun; Hammond, Tracy; Hudson, Kathy; Morin-Ducote, Garnetta; Tourassi, Georgia

    2016-03-01

    Our objective is to improve understanding of visuo-cognitive behavior in screening mammography under clinically equivalent experimental conditions. To this end, we examined pupillometric data, acquired using a head-mounted eye-tracking device, from 10 image readers (three breast-imaging radiologists and seven Radiology residents), and their corresponding diagnostic decisions for 100 screening mammograms. The corpus of mammograms comprised cases of varied pathology and breast parenchymal density. We investigated the relationship between pupillometric fluctuations, experienced by an image reader during mammographic screening, indicative of changes in mental workload, the pathological characteristics of a mammographic case, and the image readers' diagnostic decision and overall task performance. To answer these questions, we extract features from pupillometric data, and additionally applied time series shapelet analysis to extract discriminative patterns in changes in pupil dilation. Our results show that pupillometric measures are adequate predictors of mammographic case pathology, and image readers' diagnostic decision and performance with an average accuracy of 80%.

  6. Mammograms on-the-go-predictors of repeat visits to mobile mammography vans in St Louis, Missouri, USA: a case-control study.

    PubMed

    Drake, Bettina F; Abadin, Salmafatima S; Lyons, Sarah; Chang, Su-Hsin; Steward, Lauren T; Kraenzle, Susan; Goodman, Melody S

    2015-03-20

    Among women, breast cancer is the most common non-cutaneous cancer and second most common cause of cancer-related death. The purpose of this study was to determine the extent to which women use mobile mammography vans for breast cancer screening and what factors are associated with repeat visits to these vans. A case-control study. Cases are women who had a repeat visit to the mammography van. (n=2134). Women who received a mammogram as part of Siteman Cancer Center's Breast Health Outreach Program responded to surveys and provided access to their clinical records (N=8450). Only visits from 2006 to 2014 to the mammography van were included. The main outcome is having a repeat visit to the mammography van. Among the participants, 25.3% (N=2134) had multiple visits to the mobile mammography van. Data were analysed using χ(2) tests, logistic regression and negative binomial regression. Women who were aged 50-65, uninsured, or African-American had higher odds of a repeat visit to the mobile mammography van compared with women who were aged 40-50, insured, or Caucasian (OR=1.135, 95% CI 1.013 to 1.271; OR=1.302, 95% CI 1.146 to 1.479; OR=1.281, 95% CI 1.125 to 1.457), respectively. However, the odds of having a repeat visit to the van were lower among women who reported a rural ZIP code or were unemployed compared with women who provided a suburban ZIP code or were employed (OR=0.503, 95% CI 0.411 to 0.616; OR=.868, 95% CI 0.774 to 0.972), respectively. This study has identified key characteristics of women who are either more or less likely to use mobile mammography vans as their primary source of medical care for breast cancer screening and have repeat visits. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. News media coverage of a women's health contraversy: how newspapers and TV outlets covered a recent debate over screening mammography.

    PubMed

    Steele, Whitney Randolph; Mebane, Felicia; Viswanath, K; Solomon, Janice

    2005-01-01

    Over the past decade, there have been several highly visible debates about mammography that have captured professional, public and media attention. This paper looks at newspaper and television news coverage of a controversial research letter in The Lancet by Gøtzsche and Olsen (2001) that concluded that screening mammography did not prevent deaths from breast cancer. The news pieces examined for this project were published between October 2001 and March 2002 in one of eight U.S. newspapers or aired on one of six national or cable news networks. The six-month period was divided into one-week segments; the numbers of articles published or stories aired in each week were graphed to examine patterns. Each newspaper article and television transcript was then reviewed to identify its main content area and the amount of coverage for each major event was quantified. The highest number of newspaper articles appeared to result from several events during the end of January through the beginning of February. These events included the publication of another meta-analysis of mammography that disputed the original letter's conclusion and a full-page New York Times advertisement paid for by major medical organizations stating their continued support for mammography. The greatest amount of television news coverage was devoted to the announcement of the official federal guidelines by the Secretary of Health and Human Services in late February. We conclude by discussing how the flow of news coverage of medical controversies can potentially impact the actions and reactions of the public, the medical community and health policy makers.

  8. Auditing and benchmarks in screening and diagnostic mammography.

    PubMed

    Feig, Stephen A

    2007-09-01

    Radiologists can use outcome data such as cancer size and stage to determine how well their own practice provides benefit to their patients and can use measures such as screening recall rates and positive predictive values to assess how well adverse consequences are being contained. New data on national benchmarks for screening and diagnostic mammography in the United States allow radiologists to evaluate their own performance with respect to their peers. This article discusses recommended outcome values in the United States and Europe, current Mammography Quality Standards Act audit requirements, and Institute of Medicine proposals for future requirements.

  9. [Results and evaluation of 3 years of a large scale mammography program in the Ariana area of Tunisia].

    PubMed

    Bouchlaka, A; Ben Abdallah, M; Ben Aissa, R; Zaanouni, E; Kribi, L; Smida, S; M'barek, F; Ben Hamida, A; Boussen, H; Gueddana, N

    2009-07-01

    To asses and analyse the results of 3 years large scale mammography screening of breast cancer in Ariana state in Tunisia. This program, managed by the Family and Population National Office, was addressing to women aged from 49 to 69 years old residing in a area with adds up a population of 459 700 inhabitants including 52,729 women in the target age population. The screening was including a breast clinical examination and a mammography with two incidences face and external profile. The women was invited at their residence or were sensitized in the reproductive health centers, care and base health centers or by a close relation which heard of the program. An enlightened assent was submitted to the women who wished to profit from the screening. In three years, 9093 mammography were carried out of which 8244 were retained in the analyses, that is to say a rate participation of 9.6%. The rate of women recalled for suspect test was of 18.1% and it was of 13.1% among women of more than 50 years. The rate of practiced surgical biopsies was of 0.5% and the positive predictive value was of 45.5%. The average time between the date of screening and the result of the screening was 9.7 days, more important in the event of tests requiring a complementary assessment (61.7 days). On the whole 40 cancers were detected by the program, that is to say a rough rate of detected cancers, of 4.9 per thousand, in conformity with the recommendations. The percentage of invasive cancers < or = 10 mm was of 24.3 whereas percentages of in situ cancers and of cancers without ganglionic invasion were respectively of 7.7% and of 50.0%. The weakness of our study lay primarily in the rate of participation which remained weak. The methodology adopted for the sensitizing of the women is proven not very effective and did not allow inviting all eligible women. Results of the study are encouraging in spite of its limited impact and made it possible to detect an important rate of cancers of which cancers

  10. An Exploration of Changes in the Measurement of Mammography in the National Health Interview Survey.

    PubMed

    Gonzales, Felisa A; Willis, Gordon B; Breen, Nancy; Yan, Ting; Cronin, Kathy A; Taplin, Stephen H; Yu, Mandi

    2017-11-01

    Background: Using the National Health Interview Survey (NHIS), we examined the effect of question wording on estimates of past-year mammography among racially/ethnically diverse women ages 40-49 and 50-74 without a history of breast cancer. Methods: Data from one-part ("Have you had a mammogram during the past 12 months?") and two-part ("Have you ever had a mammogram"; "When did you have your most recent mammogram?") mammography history questions administered in the 2008, 2011, and 2013 NHIS were analyzed. χ 2 tests provided estimates of changes in mammography when question wording was either the same (two-part question) or differed (two-part question followed by one-part question) in the two survey years compared. Crosstabulations and regression models assessed the type, extent, and correlates of inconsistent responses to the two questions in 2013. Results: Reports of past-year mammography were slightly higher in years when the one-part question was asked than when the two-part question was asked. Nearly 10% of women provided inconsistent responses to the two questions asked in 2013. Black women ages 50 to 74 [adjusted OR (aOR), 1.50; 95% confidence interval (CI), 1.16-1.93] and women ages 40-49 in poor health (aOR, 2.22; 95% CI, 1.09-4.52) had higher odds of inconsistent responses; women without a usual source of care had lower odds (40-49: aOR, 0.42; 95% CI, 0.21-0.85; 50-74: aOR, 0.42; 95% CI, 0.24-0.74). Conclusions: Self-reports of mammography are sensitive to question wording. Researchers should use equivalent questions that have been designed to minimize response biases such as telescoping and social desirability. Impact: Trend analyses relying on differently worded questions may be misleading and conceal disparities. Cancer Epidemiol Biomarkers Prev; 26(11); 1611-8. ©2017 AACR . ©2017 American Association for Cancer Research.

  11. Fractal analysis of radiologists' visual scanning pattern in screening mammography

    NASA Astrophysics Data System (ADS)

    Alamudun, Folami T.; Yoon, Hong-Jun; Hudson, Kathy; Morin-Ducote, Garnetta; Tourassi, Georgia

    2015-03-01

    Several researchers have investigated radiologists' visual scanning patterns with respect to features such as total time examining a case, time to initially hit true lesions, number of hits, etc. The purpose of this study was to examine the complexity of the radiologists' visual scanning pattern when viewing 4-view mammographic cases, as they typically do in clinical practice. Gaze data were collected from 10 readers (3 breast imaging experts and 7 radiology residents) while reviewing 100 screening mammograms (24 normal, 26 benign, 50 malignant). The radiologists' scanpaths across the 4 mammographic views were mapped to a single 2-D image plane. Then, fractal analysis was applied on the composite 4- view scanpaths. For each case, the complexity of each radiologist's scanpath was measured using fractal dimension estimated with the box counting method. The association between the fractal dimension of the radiologists' visual scanpath, case pathology, case density, and radiologist experience was evaluated using fixed effects ANOVA. ANOVA showed that the complexity of the radiologists' visual search pattern in screening mammography is dependent on case specific attributes (breast parenchyma density and case pathology) as well as on reader attributes, namely experience level. Visual scanning patterns are significantly different for benign and malignant cases than for normal cases. There is also substantial inter-observer variability which cannot be explained only by experience level.

  12. Continuing screening mammography in women aged 70 to 79 years: impact on life expectancy and cost-effectiveness.

    PubMed

    Kerlikowske, K; Salzmann, P; Phillips, K A; Cauley, J A; Cummings, S R

    1999-12-08

    Mammography is recommended and is cost-effective for women aged 50 to 69 years, but the value of continuing screening mammography after age 69 years is not known. In particular, older women with low bone mineral density (BMD) have a lower risk of breast cancer and may benefit less from continued screening. To compare life expectancy and cost-effectiveness of screening mammography in elderly women based on 3 screening strategies. Decision analysis and cost-effectiveness analysis using a Markov model. General population of women aged 65 years or older. The analysis compared 3 strategies: (1) Undergoing biennial mammography from age 65 to 69 years; (2) undergoing biennial mammography from age 65 to 69 years, measurement of distal radial BMD at age 65 years, discontinuing screening at age 69 years in women in the lowest BMD quartile for age, and continuing biennial mammography to age 79 years in those in the top 3 quartiles of distal radius BMD; and (3) undergoing biennial mammography from age 65 to 79 years. Deaths due to breast cancer averted, life expectancy, and incremental cost-effectiveness ratios. Compared with discontinuing mammography screening at age 69 years, measuring BMD at age 65 years in 10000 women and continuing mammography to age 79 years only in women with BMD in the top 3 quartiles would prevent 9.4 deaths and add, on average, 2.1 days to life expectancy at an incremental cost of $66773 per year of life saved. Continuing mammography to age 79 years in all 10000 elderly women would prevent 1.4 additional breast cancer deaths and add only 7.2 hours to life expectancy at an incremental cost of $117689 per year of life saved compared with only continuing mammography to age 79 years in women with BMD in the top 3 quartiles. This analysis suggests that continuing mammography screening after age 69 years results in a small gain in life expectancy and is moderately cost-effective in those with high BMD and more costly in those with low BMD. Women

  13. Surveillance mammography among female Department of Defense beneficiaries: a study by race and ethnicity.

    PubMed

    Enewold, Lindsey; McGlynn, Katherine A; Zahm, Shelia H; Jatoi, Ismail; Anderson, William F; Gill, Abegail A; Shriver, Craig D; Zhu, Kangmin

    2013-10-01

    Annual surveillance mammography is recommended after a diagnosis of breast cancer. Previous studies have suggested that surveillance mammography varies by demographics and initial tumor characteristics, which are related to an individual's access to health care. The Military Health System of the Department of Defense provides beneficiaries with equal access health care and thus offers an excellent opportunity to assess whether racial differences in surveillance mammography persist when access to care is equal. Among female beneficiaries with a history of breast cancer, logistic regression was used to assess racial/ethnic variations in the use of surveillance mammography during 3 periods of 12 months each, beginning 1 year after diagnosis adjusting for demographic, tumor, and health characteristics. The rate of overall surveillance mammography decreased from 70% during the first year to 59% during the third year (P < .01). Although there was an overall tendency for surveillance mammography to be higher among minority women compared with non-Hispanic white women, after adjusting for covariates, the difference was found to be significant only during the first year among black women (odds ratio [OR], 1.46; 95% confidence interval [95% CI], 1.10-1.95) and the second year among Asian/Pacific Islander (OR, 2.29; 95%CI, 1.52-3.44) and Hispanic (OR, 1.92; 95%CI, 1.17-3.18) women. When stratified by age at diagnosis and type of breast cancer surgery performed, significant racial differences tended to be observed among younger women (aged < 50 years) and only among women who had undergone mastectomies. Minority women were equally or more likely than non-Hispanic white women to receive surveillance mammography within the Military Health System. The racial disparities in surveillance mammography reported in other studies were not observed in a system with equal access to health care. Copyright © 2013 American Cancer Society.

  14. Elimination of Cost Sharing for Screening Mammography in Medicare Advantage Plans.

    PubMed

    Trivedi, Amal N; Leyva, Bryan; Lee, Yoojin; Panagiotou, Orestis A; Dahabreh, Issa J

    2018-01-18

    The Affordable Care Act (ACA) required most insurers and the Medicare program to eliminate cost sharing for screening mammography. We conducted a difference-in-differences study of biennial screening mammography among 15,085 women 65 to 74 years of age in 24 Medicare Advantage plans that eliminated cost sharing to provide full coverage for screening mammography, as compared with 52,035 women in 48 matched control plans that had and maintained full coverage. In plans that eliminated cost sharing, adjusted rates of biennial screening mammography increased from 59.9% (95% confidence interval [CI], 54.9 to 65.0) in the 2-year period before cost-sharing elimination to 65.4% (95% CI, 61.8 to 69.0) in the 2-year period thereafter. In control plans, the rates of biennial mammography were 73.1% (95% CI, 69.2 to 77.0) and 72.8% (95% CI, 69.7 to 76.0) during the same periods, yielding a difference in differences of 5.7 percentage points (95% CI, 3.0 to 8.4). The difference in differences was 9.8 percentage points (95% CI, 4.5 to 15.2) among women living in the areas with the highest quartile of educational attainment versus 4.3 percentage points (95% CI, 0.2 to 8.4) among women in the lowest quartile. As indicated by the difference-in-differences estimates, after the elimination of cost sharing, the rate of biennial mammography increased by 6.5 percentage points (95% CI, 3.7 to 9.4) for white women and 8.4 percentage points (95% CI, 2.5 to 14.4) for black women but was almost unchanged for Hispanic women (0.4 percentage points; 95% CI, -7.3 to 8.1). The elimination of cost sharing for screening mammography under the ACA was associated with an increase in rates of use of this service among older women for whom screening is recommended. The effect was attenuated among women living in areas with lower educational attainment and was negligible among Hispanic women. (Funded by the National Institute on Aging.).

  15. Comparison of 3.0 T magnetic resonance imaging and X-ray mammography in the measurement of ductal carcinoma in situ: a comparison with histopathology.

    PubMed

    Pickles, Martin D; Gibbs, Peter; Hubbard, Anne; Rahman, Ayesha; Wieczorek, Joanna; Turnbull, Lindsay W

    2015-04-01

    To determine if MRI data obtained at 3.0 T can more accurately report the size of DCIS as compared to radiographic mammography, as a whole cohort and when subdivided by lesion characteristics. Thirty-nine participants underwent X-ray mammography and MRI prior to breast surgery for DCIS. Longest diameter (LD) measurements were recorded for each imaging modality and compared to histopathological LD via a logarithmic transformed Bland-Altman agreement plot methodology resulting in dimensionless mean difference and 95% limits of agreement (LoA). Data from 39 patients with a median age of 55 years (range 38-78 years) underwent analysis. Mastectomy was undertaken in 21 cases, while breast conserving surgery was performed in 18 subjects. Histopathological analysis revealed one low grade, nine intermediate grade, and 21 high grade lesions. The mean±standard deviation LD measurements for histopathology, X-ray mammography and MRI were 50.6±34.2 mm, 30.7±23.1 mm and 49.6±26.8 mm respectively. Bland-Altman agreement plot analysis for the whole cohort revealed not only a smaller logarithmic mean difference between MRI and histopathology (0.086), but also narrower 95% LoA (-0.941 to 1.113) compared with X-ray mammography and histopathology (mean difference -0.658, 95% LoA -3.503 to 2.187). When the level of agreement was assessed between clinically relevant subgroups additional significant differences were noted based on grade, hormonal receptor status, invasion, necrosis, mircocalcifications and growth pattern. MRI provides a more accurate estimation of DCIS size than X-ray mammography. MRI's superior ability was not only noted in general, but also for clinical relevant subdivisions such as grade and the presence or absence of necrosis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Factors affecting the palpability of breast lesion by self-examination.

    PubMed

    Lam, W W M; Chan, C P; Chan, C F; Mak, C C C; Chan, C F; Chong, K W H; Leung, M H J; Tang, M H

    2008-03-01

    This study aims to assess the accuracy of detection of breast lesion by breast self-examination and to assess different factors affecting the accuracy. All consecutive Chinese female patients, who attended our breast imaging unit in 2001, completed our questionnaire, had retrievable hard copy films, and had more than three years clinical follow-up, were recruited for this study. Different factors, such as age, menopausal status, previous experience of breastfeeding, family history of breast cancer, previous history of mastectomy or lumpectomy, hormonal therapy, oral contraceptive pills and previous history of mammography, were correlated with accuracy in self-detection of breast lesions retrospectively. The nature, size and location of the lesion, and breast size based on imaging, were also correlated with the accuracy in self-detection of breast lesions. A total of 163 questionnaires were analysed. 111 patients detected a breast lesion themselves and 24 of these lesions were false-positives. A total of 173 lesions (27 cancerous, 146 benign lesions) were documented by either ultrasonography and/or mammography, and confirmed by either histology or three-year clinical follow-up. The overall sensitivity in detecting both benign and malignant breast lesions was 71% when number of breast lesions was used as the denominator, and up to 78% sensitivity was achieved when number of patients was used as the denominator. History of mastectomy, and size and nature of the lesions were found to affect the accuracy of self-detection of breast lesions. Overall, breast self-examinations were effective in the detection of breast lesions and factors such as size of lesion, nature of the lesion and history of mastectomy affect the accuracy of the detections. Breast self-examination should be promoted for early detection of breast cancer.

  17. Energy weighting improves dose efficiency in clinical practice: implementation on a spectral photon-counting mammography system

    PubMed Central

    Berglund, Johan; Johansson, Henrik; Lundqvist, Mats; Cederström, Björn; Fredenberg, Erik

    2014-01-01

    Abstract. In x-ray imaging, contrast information content varies with photon energy. It is, therefore, possible to improve image quality by weighting photons according to energy. We have implemented and evaluated so-called energy weighting on a commercially available spectral photon-counting mammography system. The technique was evaluated using computer simulations, phantom experiments, and analysis of screening mammograms. The CNR benefit of energy weighting for a number of relevant target-background combinations measured by the three methods fell in the range of 2.2 to 5.2% when using optimal weight factors. This translates to a potential dose reduction at constant CNR in the range of 4.5 to 11%. We expect the choice of weight factor in practical implementations to be straightforward because (1) the CNR improvement was not very sensitive to weight, (2) the optimal weight was similar for all investigated target-background combinations, (3) aluminum/PMMA phantoms were found to represent clinically relevant tasks well, and (4) the optimal weight could be calculated directly from pixel values in phantom images. Reasonable agreement was found between the simulations and phantom measurements. Manual measurements on microcalcifications and automatic image analysis confirmed that the CNR improvement was detectable in energy-weighted screening mammograms. PMID:26158045

  18. Breast mass detection in mammography and tomosynthesis via fully convolutional network-based heatmap regression

    NASA Astrophysics Data System (ADS)

    Zhang, Jun; Cain, Elizabeth Hope; Saha, Ashirbani; Zhu, Zhe; Mazurowski, Maciej A.

    2018-02-01

    Breast mass detection in mammography and digital breast tomosynthesis (DBT) is an essential step in computerized breast cancer analysis. Deep learning-based methods incorporate feature extraction and model learning into a unified framework and have achieved impressive performance in various medical applications (e.g., disease diagnosis, tumor detection, and landmark detection). However, these methods require large-scale accurately annotated data. Unfortunately, it is challenging to get precise annotations of breast masses. To address this issue, we propose a fully convolutional network (FCN) based heatmap regression method for breast mass detection, using only weakly annotated mass regions in mammography images. Specifically, we first generate heat maps of masses based on human-annotated rough regions for breast masses. We then develop an FCN model for end-to-end heatmap regression with an F-score loss function, where the mammography images are regarded as the input and heatmaps for breast masses are used as the output. Finally, the probability map of mass locations can be estimated with the trained model. Experimental results on a mammography dataset with 439 subjects demonstrate the effectiveness of our method. Furthermore, we evaluate whether we can use mammography data to improve detection models for DBT, since mammography shares similar structure with tomosynthesis. We propose a transfer learning strategy by fine-tuning the learned FCN model from mammography images. We test this approach on a small tomosynthesis dataset with only 40 subjects, and we show an improvement in the detection performance as compared to training the model from scratch.

  19. Digital Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters (TLDs)

    DTIC Science & Technology

    2003-06-18

    Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters ( TLDs ) 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...34Digital Mammography Breast Dosimetry Using Copper- Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters ( TLDs )" Author: LT John J. Tomon...Title of Thesis: " Digital Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent

  20. Adding the power of iodinated contrast media to the credibility of mammography in breast cancer diagnosis.

    PubMed

    Tsigginou, Alexandra; Gkali, Christina; Chalazonitis, Athanasios; Feida, Eleni; Vlachos, Dimitrios Efthymios; Zagouri, Flora; Rellias, Ioannis; Dimitrakakis, Constantine

    2016-11-01

    Dual-energy contrast-enhanced spectral mammography (CESM) represents a relatively new diagnostic tool adjunct to mammography. The aim of this study was to strengthen the breast imaging-reporting and data system (BIRADS) classification score in order to improve early breast cancer diagnosis. For this reason, we propose a sum score, termed malignancy potential score (MPS), incorporating the standard BIRADS score and our proposed CESM score. From September 2014 to September 2015, 216 females (age range, 26-85 years; mean age 54.6 years) underwent CESM evaluation of mammographic findings that were primarily assessed as BIRADS 2-5. 10 of these patients had bilateral findings; a total of 226 lesions were examined. High-energy image evaluation was based on the intensity of contrast enhancement of the lesion compared with background enhancement, categorized as Type -1, 0, 1 or 2 enhancement. Histopathology reports were compared with imaging assessment. 98 of 226 lesions were malignant and 128 of 226 lesions were benign. The area under the curve was 0.843, 0.888 and 0.917 for mammographic BIRADS score, CESM score and MPS, respectively, with p-value < 0.05. The sensitivity, specificity and accuracy rates were 91.83, 80.47 and 85.40%, respectively, when a best MPS cut-off point of 4 was used. The malignancy potential score (MPS) has higher diagnostic performance than digital mammography or CESM alone. MPS empowers the credibility of the digital mammography BIRADS score and our proposed type of enhancement in dual-energy CESM and is a diagnostic tool that increases the accuracy rate in early breast cancer diagnosis.

  1. Impact of the Introduction of Digital Mammography in an Organized Screening Program on the Recall and Detection Rate.

    PubMed

    Campari, Cinzia; Giorgi Rossi, Paolo; Mori, Carlo Alberto; Ravaioli, Sara; Nitrosi, Andrea; Vacondio, Rita; Mancuso, Pamela; Cattani, Antonella; Pattacini, Pierpaolo

    2016-04-01

    In 2012, the Reggio Emilia Breast Cancer Screening Program introduced digital mammography in all its facilities at the same time. The aim of this work is to analyze the impact of digital mammography introduction on the recall rate, detection rate, and positive predictive value. The program actively invites women aged 45-74 years. We included women screened in 2011, all of whom underwent film-screen mammography, and all women screened in 2012, all of whom underwent digital mammography. Double reading was used for all mammograms, with arbitration in the event of disagreement. A total of 42,240 women underwent screen-film mammography and 45,196 underwent digital mammography. The recall rate increased from 3.3 to 4.4% in the first year of digital mammography (relative recall adjusted by age and round 1.46, 95% CI = 1.37-1.56); the positivity rate for each individual reading, before arbitration, rose from 3 to 5.7%. The digital mammography recall rate decreased during 2012: after 12 months, it was similar to the recall rate with screen-film mammography. The detection rate was similar: 5.9/1000 and 5.2/1000 with screen-film and digital mammography, respectively (adjusted relative detection rate 0.95, 95% CI = 0.79-1.13). The relative detection rate for ductal carcinoma in situ remained the same. The introduction of digital mammography to our organized screening program had a negative impact on specificity, thereby increasing the recall rate. The effect was limited to the first 12 months after introduction and was attenuated by the double reading with arbitration. We did not observe any relevant effects on the detection rate.

  2. Reconstruction of Absorbed Doses to Fibroglandular Tissue of the Breast of Women undergoing Mammography (1960 to the Present)

    PubMed Central

    Thierry-Chef, Isabelle; Simon, Steven L.; Weinstock, Robert M.; Kwon, Deukwoo; Linet, Martha S.

    2013-01-01

    The assessment of potential benefits versus harms from mammographic examinations as described in the controversial breast cancer screening recommendations of the U.S. Preventive Task Force included limited consideration of absorbed dose to the fibroglandular tissue of the breast (glandular tissue dose), the tissue at risk for breast cancer. Epidemiological studies on cancer risks associated with diagnostic radiological examinations often lack accurate information on glandular tissue dose, and there is a clear need for better estimates of these doses. Our objective was to develop a quantitative summary of glandular tissue doses from mammography by considering sources of variation over time in key parameters including imaging protocols, x-ray target materials, voltage, filtration, incident air kerma, compressed breast thickness, and breast composition. We estimated the minimum, maximum, and mean values for glandular tissue dose for populations of exposed women within 5-year periods from 1960 to the present, with the minimum to maximum range likely including 90% to 95% of the entirety of the dose range from mammography in North America and Europe. Glandular tissue dose from a single view in mammography is presently about 2 mGy, about one-sixth the dose in the 1960s. The ratio of our estimates of maximum to minimum glandular tissue doses for average-size breasts was about 100 in the 1960s compared to a ratio of about 5 in recent years. Findings from our analysis provide quantitative information on glandular tissue doses from mammographic examinations which can be used in epidemiologic studies of breast cancer. PMID:21988547

  3. Computer assisted Objective structured clinical examination versus Objective structured clinical examination in assessment of Dermatology undergraduate students.

    PubMed

    Chaudhary, Richa; Grover, Chander; Bhattacharya, S N; Sharma, Arun

    2017-01-01

    The assessment of dermatology undergraduates is being done through computer assisted objective structured clinical examination at our institution for the last 4 years. We attempted to compare objective structured clinical examination (OSCE) and computer assisted objective structured clinical examination (CA-OSCE) as assessment tools. To assess the relative effectiveness of CA-OSCE and OSCE as assessment tools for undergraduate dermatology trainees. Students underwent CA-OSCE as well as OSCE-based evaluation of equal weightage as an end of posting assessment. The attendance as well as the marks in both the examination formats were meticulously recorded and statistically analyzed using SPSS version 20.0. Intercooled Stata V9.0 was used to assess the reliability and internal consistency of the examinations conducted. Feedback from both students and examiners was also recorded. The mean attendance for the study group was 77% ± 12.0%. The average score on CA- OSCE and OSCE was 47.4% ± 19.8% and 53.5% ± 18%, respectively. These scores showed a mutually positive correlation, with Spearman's coefficient being 0.593. Spearman's rank correlation coefficient between attendance scores and assessment score was 0.485 for OSCE and 0.451 for CA-OSCE. The Cronbach's alpha coefficient for all the tests ranged from 0.76 to 0.87 indicating high reliability. The comparison was based on a single batch of 139 students. Such an evaluation on more students in larger number of batches over successive years could help throw more light on the subject. Computer assisted objective structured clinical examination was found to be a valid, reliable and effective format for dermatology assessment, being rated as the preferred format by examiners.

  4. Breast masses in mammography classification with local contour features.

    PubMed

    Li, Haixia; Meng, Xianjing; Wang, Tingwen; Tang, Yuchun; Yin, Yilong

    2017-04-14

    Mammography is one of the most popular tools for early detection of breast cancer. Contour of breast mass in mammography is very important information to distinguish benign and malignant mass. Contour of benign mass is smooth and round or oval, while malignant mass has irregular shape and spiculated contour. Several studies have shown that 1D signature translated from 2D contour can describe the contour features well. In this paper, we propose a new method to translate 2D contour of breast mass in mammography into 1D signature. The method can describe not only the contour features but also the regularity of breast mass. Then we segment the whole 1D signature into different subsections. We extract four local features including a new contour descriptor from the subsections. The new contour descriptor is root mean square (RMS) slope. It can describe the roughness of the contour. KNN, SVM and ANN classifier are used to classify benign breast mass and malignant mass. The proposed method is tested on a set with 323 contours including 143 benign masses and 180 malignant ones from digital database of screening mammography (DDSM). The best accuracy of classification is 99.66% using the feature of root mean square slope with SVM classifier. The performance of the proposed method is better than traditional method. In addition, RMS slope is an effective feature comparable to most of the existing features.

  5. False-negative contrast-enhanced spectral mammography: use of more than one imaging modality and application of the triple test avoids misdiagnosis.

    PubMed

    Taylor, Donna; O'Hanlon, Susan; Latham, Bruce

    2017-03-31

    A 50-year-old woman presented with chest tenderness. On examination, both breasts were lumpy. Bilateral mammography showed heterogeneously dense parenchyma, with possible stromal distortion laterally on the right at the 0900 position. On ultrasound (US), a corresponding 13×9×10 mm irregular hypoechoic mass with internal vascularity was noted and both breasts had a complex heterogeneous fibroglandular background pattern. US-guided core biopsy with marker clip insertion was performed with the diagnosis of a grade 2 invasive ductal carcinoma (IDC). In view of the parenchymal pattern on mammography and US, contrast-enhanced spectral mammography (CESM) was performed for local staging. Mild background enhancement was noted, but there was no enhancement at the lesion site. The patient elected to have bilateral mastectomies and sentinel node biopsies. Final histopathology showed a node negative 11 mm grade 2 oestrogen and progesterone receptor positive, IDC. 2017 BMJ Publishing Group Ltd.

  6. Subgroup-specific effects of questionnaire wording on population-based estimates of mammography prevalence.

    PubMed Central

    Siegel, P Z; Qualters, J R; Mowery, P D; Campostrini, S; Leutzinger, C; McQueen, D V

    2001-01-01

    OBJECTIVES: This study investigated whether an apparent downturn in prevalence rates of mammography use reported in the 1992 Behavioral Risk Factor Surveillance System (BRFSS) questionnaire resulted from a change in questionnaire wording. METHODS: In a pretest-posttest design (1990-1991 vs 1992), piecewise linear regression analyses were based on monthly prevalence estimates of mammography use among female BRFSS respondents 40 years or older. RESULTS: Self-reported mammography use was lower by 3.5 percentage points (95% confidence interval [CI] = 1.5, 5.5) overall--and lower by 13.6 percentage points (95% CI = 2.6, 24.6) among Black women with less than a high school education--when predicted from 1992 data than when predicted from 1990-1991 data. CONCLUSIONS: A change in questionnaire wording in the BRFSS caused demographic-specific effects in population-based estimates of mammography use. PMID:11344896

  7. Development of cultural belief scales for mammography screening.

    PubMed

    Russell, Kathleen M; Champion, Victoria L; Perkins, Susan M

    2003-01-01

    To develop instruments to measure culturally related variables that may influence mammography screening behaviors in African American women. Instrumentation methodology. Community organizations and public housing in the Indianapolis, IN, area. 111 African American women with a mean age of 60.2 years and 64 Caucasian women with a mean age of 60 years. After item development, scales were administered. Data were analyzed by factor analysis, item analysis via internal consistency reliability using Cronbach's alpha, and independent t tests and logistic regression analysis to test theoretical relationships. Personal space preferences, health temporal orientation, and perceived personal control. Space items were factored into interpersonal and physical scales. Temporal orientation items were loaded on one factor, creating a one-dimensional scale. Control items were factored into internal and external control scales. Cronbach's alpha coefficients for the scales ranged from 0.76-0.88. Interpersonal space preference, health temporal orientation, and perceived internal control scales each were predictive of mammography screening adherence. The three tested scales were reliable and valid. Scales, on average, did not differ between African American and Caucasian populations. These scales may be useful in future investigations aimed at increasing mammography screening in African American and Caucasian women.

  8. Computer-aided diagnostics of screening mammography using content-based image retrieval

    NASA Astrophysics Data System (ADS)

    Deserno, Thomas M.; Soiron, Michael; de Oliveira, Júlia E. E.; de A. Araújo, Arnaldo

    2012-03-01

    Breast cancer is one of the main causes of death among women in occidental countries. In the last years, screening mammography has been established worldwide for early detection of breast cancer, and computer-aided diagnostics (CAD) is being developed to assist physicians reading mammograms. A promising method for CAD is content-based image retrieval (CBIR). Recently, we have developed a classification scheme of suspicious tissue pattern based on the support vector machine (SVM). In this paper, we continue moving towards automatic CAD of screening mammography. The experiments are based on in total 10,509 radiographs that have been collected from different sources. From this, 3,375 images are provided with one and 430 radiographs with more than one chain code annotation of cancerous regions. In different experiments, this data is divided into 12 and 20 classes, distinguishing between four categories of tissue density, three categories of pathology and in the 20 class problem two categories of different types of lesions. Balancing the number of images in each class yields 233 and 45 images remaining in each of the 12 and 20 classes, respectively. Using a two-dimensional principal component analysis, features are extracted from small patches of 128 x 128 pixels and classified by means of a SVM. Overall, the accuracy of the raw classification was 61.6 % and 52.1 % for the 12 and the 20 class problem, respectively. The confusion matrices are assessed for detailed analysis. Furthermore, an implementation of a SVM-based CBIR system for CADx in screening mammography is presented. In conclusion, with a smarter patch extraction, the CBIR approach might reach precision rates that are helpful for the physicians. This, however, needs more comprehensive evaluation on clinical data.

  9. Do cultural factors predict mammography behaviour among Korean immigrants in the USA?

    PubMed

    Lee, Hanju; Kim, Jiyun; Han, Hae-Ra

    2009-12-01

    This paper is a report of a study of the correlates of mammogram use among Korean American women. Despite the increasing incidence of and mortality from breast cancer, Asian women in the United States of America report consistently low rates of mammography screening. A number of health beliefs and sociodemographic characteristics have been associated with mammogram participation among these women. However, studies systematically investigating cultural factors in relation to mammogram experience have been scarce. We measured screening-related health beliefs, modesty and use of Eastern medicine in 100 Korean American women in 2006. Hierarchical logistic regression was used to examine the unique contribution of the study variables, after accounting for sociodemographic characteristics. Only 51% reported past mammogram use. Korean American women who had previously had mammograms were statistically significantly older and had higher perceived benefit scores than those who had not. Perceived benefits (odds ratio = 6.3, 95% confidence interval = 2.12, 18.76) and breast cancer susceptibility (odds ratio = 3.18, 95% confidence interval = 1.06, 9.59) were statistically significant correlates of mammography experience, whereas cultural factors did not correlate. Post hoc analysis showed that for women with some or good English skills, cultural factors statistically significantly correlated with health beliefs and breast cancer knowledge (P < 0.05). Nurses should consider the inclusion in culturally tailored interventions of more targeted outreach and healthcare system navigation assistance for promoting mammography screening in Korean American women. Further research is needed to unravel the interplay between acculturation, cultural factors and health beliefs related to cancer screening behaviours of Korean American women.

  10. Attitudes and Beliefs Associated with Mammography in a Multiethnic Population in Israel

    ERIC Educational Resources Information Center

    Baron-Epel, Orna

    2010-01-01

    This article highlights beliefs, attitudes, and barriers that are associated with mammography use in four distinct cultural and ethnic groups in Israel: veteran, ultra-orthodox, and immigrant Jewish and Arab women. A random telephone survey of 1,550 women was performed. Information from claims records concerning mammography use was obtained for…

  11. Slit-scanning differential x-ray phase-contrast mammography: proof-of-concept experimental studies.

    PubMed

    Koehler, Thomas; Daerr, Heiner; Martens, Gerhard; Kuhn, Norbert; Löscher, Stefan; van Stevendaal, Udo; Roessl, Ewald

    2015-04-01

    The purpose of this work is to investigate the feasibility of grating-based, differential phase-contrast, full-field digital mammography (FFDM) in terms of the requirements for field-of-view (FOV), mechanical stability, and scan time. A rigid, actuator-free Talbot interferometric unit was designed and integrated into a state-of-the-art x-ray slit-scanning mammography system, namely, the Philips MicroDose L30 FFDM system. A dedicated phase-acquisition and phase retrieval method was developed and implemented that exploits the redundancy of the data acquisition inherent to the slit-scanning approach to image generation of the system. No modifications to the scan arm motion control were implemented. The authors achieve a FOV of 160 × 196 mm consisting of two disjoint areas measuring 77 × 196 mm with a gap of 6 mm between them. Typical scanning times vary between 10 and 15 s and dose levels are lower than typical FFDM doses for conventional scans with identical acquisition parameters due to the presence of the source-grating G0. Only minor to moderate artifacts are observed in the three reconstructed images, indicating that mechanical vibrations induced by other system components do not prevent the use of the platform for phase contrast imaging. To the best of our knowledge, this is the first attempt to integrate x-ray gratings hardware into a clinical mammography unit. The results demonstrate that a scanning differential phase contrast FFDM system that meets the requirements of FOV, stability, scan time, and dose can be build.

  12. Prognostic value of contrast-enhanced MR mammography in patients with breast cancer.

    PubMed

    Fischer, U; Kopka, L; Brinck, U; Korabiowska, M; Schauer, A; Grabbe, E

    1997-01-01

    The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1, c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes.

  13. Validation of the English and Spanish Mammography Beliefs and Attitudes Questionnaire.

    PubMed

    Lopez-McKee, Gloria; Bader, Julia

    2011-03-21

    Breast cancer is the leading cause of cancer deaths among Hispanic women in the United States. Unfortunately Hispanic women exhibit poor mammography screening participation, are diagnosed at later stages of the disease, and have lower survival rates than non-Hispanic white women. Several cultural and psycho-social factors have been found to influence mammography screening participation among Hispanic women. We will begin by presenting the theoretical framework that grounded this research program to develop an instrument to assess factors contributing to poor mammography participation among Hispanic women. We will also summarize the early stages in the development of the English and Spanish Mammography Beliefs and Attitudes Questionnaire (MBAQ and SMBAQ) for use with low-health-literacy Mexican-American women. Next we will describe the initial psychometric testing of the MBAQ/SMBAQ, after which we will present the psychometric testing of the SMBAQ with low-health-literacy women. This will be followed by a discussion of the modification of the MBAQ and SMBAQ subscales. We'll conclude with a discussion of the instruments and share our assessment regarding the limitations of this research program, where the program stands to date, and the implications for practice and future research.

  14. The effectiveness of a nurse-delivered breast health promotion program on breast cancer screening behaviours in non-adherent Turkish women: A randomized controlled trial.

    PubMed

    Secginli, Selda; Nahcivan, Nursen O

    2011-01-01

    Few studies have investigated breast health programs to promote rates of having a mammography, clinical breast examination and breast self-examination among non-adherent Turkish women. To determine the effectiveness of a breast health promotion program on mammography and clinical breast examination use, breast self-examination frequency and proficiency (breast self-examination skills and lump detection), breast health knowledge and health beliefs about breast cancer screening in a sample of Turkish women. Experimental (pretest-posttest control group). A community-based setting in Istanbul, Turkey. 190 Non-adherent women (intervention group=97, control group=93) aged 41 and older, residing in Istanbul, Turkey. The intervention group (n=97) received a 120-min breast health promotion program based on health belief model including a breast health education, film, breast self-examination instruction, and a booklet, a calendar, a card designed specifically for the study. The control group (n=93) received general information except breast health. Data were collected before the program, immediately after the program, and at 3- and 6-month post-program. The outcome measures are the mammography, clinical breast examination, and breast self-examination frequency, breast self-examination proficiency, breast health knowledge, and health beliefs (perceived susceptibility to breast cancer, benefits to mammography and breast self-examination, barriers of mammography and breast self-examination, confidence in performing breast self-examination). The breast health promotion program significantly increased breast self-examination frequency and proficiency and breast health knowledge. No significant differences existed in mammography and clinical breast examination rates between the two groups at 6 months. The program was effective in increasing perceived susceptibility to breast cancer, perceived benefits of mammography and breast self-examination, and confidence of breast self-examination

  15. Clinical versus ultrasound examination of the thyroid gland in common clinical practice.

    PubMed

    Brander, A; Viikinkoski, P; Tuuhea, J; Voutilainen, L; Kivisaari, L

    1992-01-01

    In a prospective series of 72 patients, clinical and ultrasonographic examination of the thyroid gland were compared in detail. Normal-sized lobes were differentiated from enlarged ones both by inspection and by palpation. When lobar size was assessed by palpation, the estimate was most clearly influenced by increase in width. The correlation between two examiners in lobe size assessment was significant. In the classification of thyroid disease as diffuse, solitary, or multinodular, clinical examination and ultrasonography correlated significantly. However, only one third of the clinically solitary nodules proved to be solitary by ultrasound examination. Of 77 separate nodules, 43 escaped detection on clinical examination. Of these 43, 14 nodules exceeded 2 cm in diameter. It is concluded that the use of ultrasonography frequently alters the primary evaluation of thyroid nodularity based on palpation.

  16. Comparative Study Of Image Enhancement Algorithms For Digital And Film Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delgado-Gonzalez, A.; Sanmiguel, R. E.

    2008-08-11

    Here we discuss the application of edge enhancement algorithms on images obtained with a Mammography System which has a Selenium Detector and on the other hand, on images obtained from digitized film mammography. Comparative analysis of such images includes the study of technical aspects of image acquisition, storage, compression and display. A protocol for a local database has been created as a result of this study.

  17. Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code.

    PubMed

    Gholamkar, Lida; Mowlavi, Ali Asghar; Sadeghi, Mahdi; Athari, Mitra

    2016-10-01

    X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast during mammography examinations as well as investigating factors that influence the mean glandular dose (MGD). One of the precise methods for determination of MGD absorbed by the breast is Monte Carlo simulation method which is widely used to assess the dose. We studied some different X-ray sources and exposure factors that affect the MGD. "Midi-future" digital mammography system with amorphous-selenium detector was simulated using the Monte Carlo N-particle extended (MCNPX) code. Different anode/filter combinations such as tungsten/silver (W/Ag), tungsten/rhodium (W/Rh), and rhodium/aluminium (Rh/Al) were simulated in this study. The voltage of X-ray tube ranged from 24 kV to 32 kV with 2 kV intervals and the breast phantom thickness ranged from 3 to 8 cm, and glandular fraction g varied from 10% to 100%. MGD was measured for different anode/filter combinations and the effects of changing tube voltage, phantom thickness, combination and glandular breast tissue on MGD were studied. As glandular g and X-ray tube voltage increased, the breast dose increased too, and the increase of breast phantom thickness led to the decrease of MGD. The obtained results for MGD were consistent with the result of Boone et al. that was previously reported. By comparing the results, we saw that W/Rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with W/Ag and Rh/Al. Moreover, breast thickness and g value have significant effects on MGD.

  18. Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code

    PubMed Central

    Gholamkar, Lida; Mowlavi, Ali Asghar; Sadeghi, Mahdi; Athari, Mitra

    2016-01-01

    Background X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. Objectives The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast during mammography examinations as well as investigating factors that influence the mean glandular dose (MGD). One of the precise methods for determination of MGD absorbed by the breast is Monte Carlo simulation method which is widely used to assess the dose. Materials and Methods We studied some different X-ray sources and exposure factors that affect the MGD. “Midi-future” digital mammography system with amorphous-selenium detector was simulated using the Monte Carlo N-particle extended (MCNPX) code. Different anode/filter combinations such as tungsten/silver (W/Ag), tungsten/rhodium (W/Rh), and rhodium/aluminium (Rh/Al) were simulated in this study. The voltage of X-ray tube ranged from 24 kV to 32 kV with 2 kV intervals and the breast phantom thickness ranged from 3 to 8 cm, and glandular fraction g varied from 10% to 100%. Results MGD was measured for different anode/filter combinations and the effects of changing tube voltage, phantom thickness, combination and glandular breast tissue on MGD were studied. As glandular g and X-ray tube voltage increased, the breast dose increased too, and the increase of breast phantom thickness led to the decrease of MGD. The obtained results for MGD were consistent with the result of Boone et al. that was previously reported. Conclusion By comparing the results, we saw that W/Rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with W/Ag and Rh/Al. Moreover, breast thickness and g value have significant effects on MGD. PMID:27895876

  19. The U.S. Online News Coverage of Mammography Based on a Google News Search.

    PubMed

    Young Lin, Leng Leng; Rosenkrantz, Andrew B

    2017-12-01

    To characterize online news coverage relating to mammography, including articles' stance toward screening mammography. Google News was used to search U.S. news sites over a 9-year period (2006-2015) based on the search terms "mammography" and "mammogram." The top 100 search results were recorded. Identified articles were manually reviewed. The top 100 news articles were from the following sources: local news outlet (50%), national news outlet (24%), nonimaging medical source (13%), entertainment or culture news outlet (6%), business news outlet (4%), peer-reviewed journal (1%), and radiology news outlet (1%). Most common major themes were the screening mammography controversy (29%), description of a new breast imaging technology (23%), dense breasts (11%), and promotion of a public screening initiative (11%). For the most recent year, article stance toward screening mammography was 59%, favorable; 16%, unfavorable; and 25%, neutral. After 2010, there was an abrupt shift in articles' stances from neutral to both favorable and unfavorable. A wide range of online news sources addressed a range of issues related to mammography. National, rather than local, news sites were more likely to focus on the screening controversy and more likely to take an unfavorable view. The controversial United States Preventive Services Task Force guidelines may have influenced articles to take a stance on screening mammography. As such online news may impact public perception of the topic and thus potentially impact guideline adherence, radiologists are encouraged to maintain awareness of this online coverage and to support the online dissemination of reliable and accurate information. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. Contrast-enhanced spectral mammography in patients with MRI contraindications.

    PubMed

    Richter, Vivien; Hatterman, Valerie; Preibsch, Heike; Bahrs, Sonja D; Hahn, Markus; Nikolaou, Konstantin; Wiesinger, Benjamin

    2017-01-01

    Background Contrast-enhanced spectral mammography (CESM) is a novel breast imaging technique providing comparable diagnostic accuracy to breast magnetic resonance imaging (MRI). Purpose To show that CESM in patients with MRI contraindications is feasible, accurate, and useful as a problem-solving tool, and to highlight its limitations. Material and Methods A total of 118 patients with MRI contraindications were examined by CESM. Histology was obtained in 94 lesions and used as gold standard for diagnostic accuracy calculations. Imaging data were reviewed retrospectively for feasibility, accuracy, and technical problems. The diagnostic yield of CESM as a problem-solving tool and for therapy response evaluation was reviewed separately. Results CESM was more accurate than mammography (MG) for lesion categorization (r = 0.731, P < 0.0001 vs. r = 0.279, P = 0.006) and for lesion size estimation (r = 0.738 vs. r = 0.689, P < 0.0001). Negative predictive value of CESM was significantly higher than of MG (85.71% vs. 30.77%, P < 0.0001). When used for problem-solving, CESM changed patient management in 2/8 (25%) cases. Superposition artifacts and timing problems affected diagnostic utility in 3/118 (2.5%) patients. Conclusion CESM is a feasible and accurate alternative for patients with MRI contraindications, but it is necessary to be aware of the method's technical limitations.

  1. The Role of Social Capital in African-American Women's Use of Mammography

    PubMed Central

    Dean, Lorraine; Subramanian, SV; Williams, David R.; Armstrong, Katrina; Charles, Camille Zubrinsky; Kawachi, Ichiro

    2014-01-01

    Black/African-American women are more likely to get breast cancer at a young age and/or be diagnosed at a late disease stage, pointing to a greater need to promote mammography for Black women at earlier ages than are currently recommended. This study explores how perceived neighborhood social capital, that is, perceptions of how tight-knit a neighborhood is and what power that confers to neighborhood members, relates to use of mammography for Black women in Philadelphia. Living in a community with tight social ties (social cohesion) or that have a collective motivation for community change (collective efficacy) may increase the likelihood that an individual woman in that community will hear health messages from other community members and neighbors (diffusion of information) and will have access to health-related resources that allow them to engage in healthy behaviors. No prior studies have explored the role of social capital in decisions for mammography use. Using multilevel logistic regression, we analyzed self-report of mammography in the past year for 2,586, Black women over age 40 across 381 Philadelphia, Pennsylvania USA census tracts. Our study included individual demographic and aggregates of individual-level social capital data from the Public Health Management Corporation's 2004, 2006, and 2008 Community Health Database waves, and 2000 US Census sociodemographic characteristics. Individual perceptions that a Black woman's neighborhood had high social capital, specifically collective efficacy, had a positive and statistically significant association with mammography use (OR=1.40, CI: 1.05, 1.85). Our findings suggest that an individual woman's perception of greater neighborhood social capital may be related to increased mammography use. Although this analysis could not determine the direction of causality, it suggests that social capital may play a role in cancer preventive screening for African-American women in Philadelphia, which warrants further study

  2. Screening mammography uptake within Australia and Scotland in rural and urban populations

    PubMed Central

    Leung, Janni; Macleod, Catriona; McLaughlin, Deirdre; Woods, Laura M.; Henderson, Robert; Watson, Angus; Kyle, Richard G.; Hubbard, Gill; Mullen, Russell; Atherton, Iain

    2015-01-01

    Objective To test the hypothesis that rural populations had lower uptake of screening mammography than urban populations in the Scottish and Australian setting. Method Scottish data are based upon information from the Scottish Breast Screening Programme Information System describing uptake among women residing within the NHS Highland Health Board area who were invited to attend for screening during the 2008 to 2010 round (N = 27,416). Australian data were drawn from the 2010 survey of the 1946–51 cohort of the Australian Longitudinal Study on Women's Health (N = 9890 women). Results Contrary to our hypothesis, results indicated that women living in rural areas were not less likely to attend for screening mammography compared to women living in urban areas in both Scotland (OR for rural = 1.17, 95% CI = 1.06–1.29) and Australia (OR for rural = 1.15, 95% CI = 1.01–1.31). Conclusions The absence of rural–urban differences in attendance at screening mammography demonstrates that rurality is not necessarily an insurmountable barrier to screening mammography. PMID:26844118

  3. Screening mammography uptake within Australia and Scotland in rural and urban populations.

    PubMed

    Leung, Janni; Macleod, Catriona; McLaughlin, Deirdre; Woods, Laura M; Henderson, Robert; Watson, Angus; Kyle, Richard G; Hubbard, Gill; Mullen, Russell; Atherton, Iain

    2015-01-01

    To test the hypothesis that rural populations had lower uptake of screening mammography than urban populations in the Scottish and Australian setting. Scottish data are based upon information from the Scottish Breast Screening Programme Information System describing uptake among women residing within the NHS Highland Health Board area who were invited to attend for screening during the 2008 to 2010 round (N = 27,416). Australian data were drawn from the 2010 survey of the 1946-51 cohort of the Australian Longitudinal Study on Women's Health (N = 9890 women). Contrary to our hypothesis, results indicated that women living in rural areas were not less likely to attend for screening mammography compared to women living in urban areas in both Scotland (OR for rural = 1.17, 95% CI = 1.06-1.29) and Australia (OR for rural = 1.15, 95% CI = 1.01-1.31). The absence of rural-urban differences in attendance at screening mammography demonstrates that rurality is not necessarily an insurmountable barrier to screening mammography.

  4. Perceived susceptibility to breast cancer moderates the effect of gain- and loss-framed messages on use of screening mammography.

    PubMed

    Gallagher, Kristel M; Updegraff, John A; Rothman, Alexander J; Sims, Linda

    2011-03-01

    This study examined the role of three distinct beliefs about risk (risks associated with screening, construal of the function of screening as health-affirming or illness-detecting, and perceived susceptibility to breast cancer) in moderating women's responses to framed messages that promote mammography. Three hundred fifty-five women recruited from an inner city hospital, nonadherent to guidelines for receiving annual screening mammograms,were randomly assigned to view a gain- or loss-framed video message about the importance of mammography. Mammography screening was self-reported at a 3-month follow-up. Only perceived susceptibility to breast cancer significantly moderated the effect of message framing on screening. Women with average and higher levels of perceived susceptibility for breast cancer were significantly more likely to report screening after viewing a loss-framed message compared to a gain-framed message. No effects of framing on reported screening were observed for women with lower levels of perceived susceptibility. The study identifies a key role for perceived susceptibility in shaping responses to framed messages that promote cancer screenings. (c) 2011 APA, all rights reserved

  5. A comparison of the performance of modern screen-film and digital mammography systems.

    PubMed

    Monnin, P; Gutierrez, D; Bulling, S; Lepori, D; Valley, J-F; Verdun, F R

    2005-06-07

    This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.

  6. [Examination of Stereotactic Mammotome Biopsy for Microcalcification in Our Hospital].

    PubMed

    Sueoka, Noriko; Ishizuka, Mariko; Yoshikawa, Katsuhiro; Tsubota, Yu; Yamamoto, Daigo; Kon, Masanori

    2017-11-01

    We introduced stereotactic mammotome biopsy(ST-MMT)for the purpose of screening and other institutions. There are many benign cases to be diagnosed by pathological findings, so it is thought to be necessary to examine the adaptation of STMMT again. We examined the performance of ST-MMT in a case of a non-palpating calcification lesion. Between August 2013 and December 2016, ST-MMT biopsies were performed for 247 microcalcified lesions revealed by mammography(in both breasts in 9 patients; twice in the ipsilateral breast in 2 patients). The mean age of all patients was 46 years(range, 24- 89 years). We found 39 cases(15.8%)of breast cancer. A final diagnosis of breast cancer was made in 39 patients, who comprised 0% of those with Category 2, 53.8% of those with Category 3, 35.9% of those with Category 4, and 10.3% of those with Category 5. Regarding the morphology and distribution of microcalcifications, breast cancer accounted for 46.2%, 5.1%, 2.6%, 35.9%, 7.7%, and 2.6% of the cases with small round/clustered, amorphous/clustered, pleomorphic/clus- tered, pleomorphic/linear segmental, and fine linear/clustered patterns, respectively. Also, we examined each of the patients, (1) who underwent mammography for medical examinations, (2) who underwent mammography performed at other institutions, (3) who underwent follow-up for microcalcifications and postoperative follow-up mammography. The proportions of breast cancer diagnoses were (1) 11.4%, (2) 20.6%, and (3) 7.1%. Proportions of Category 3 breast cancer were (1) 10.3%, (2) 38.5%, and (3) 5.1%. Among the cases in which ST-MMT was performed in this study, Category 3 accounted for more than half. However, 10.9%(21/192 lesions)were diagnosed as malignant in Category 3. The diagnosis of breast cancer in pa- tients who underwent mammography performed at other institutions was not observed in 79.4%(104/131 lesions), and among the 104 lesions, as a result of reassessment of calcification in our hospital, Category 2 was

  7. Mammography in females with an implanted medical device: impact on image quality, pain and anxiety.

    PubMed

    Paap, Ellen; Witjes, Marloes; van Landsveld-Verhoeven, Cary; Pijnappel, Ruud M; Maas, Angela H E M; Broeders, Mireille J M

    2016-10-01

    To assess the image quality of mammograms in females with an implanted medical device (IMD), to evaluate pain and anxiety during mammography in these females and to investigate the experience of radiographers. Image quality was evaluated by two radiographers and one radiologist in the images of females with an IMD participating in the Dutch screening programme (clients). Pain and anxiety were scored using a Numeric Rating Scale in both clients visiting a screening organization and patients from the Isala Hospital, Zwolle. Experience of screening radiographers was collected with a questionnaire. Images of the breast with IMD showed reduced contrast in craniocaudal (CC) and mediolateral-oblique (MLO) views [by both the radiographers and radiologist (range: 11-29%)], less projected breast tissue [only radiographers; CC lateral side: 25.5%, 95% confidence interval (CI): 18.7-32.2] and reduced projection of the pectoral muscle (only radiographers; MLO width pectoral muscle: 31.5%, 95% CI: 24.4-38.7). Clients experienced more pain and anxiety during mammography in the breast with IMD compared to the breast without IMD in the breast (pain difference CC: 0.48 ± 0.16, p = 0.003; pain difference MLO: 0.46 ± 0.16, p = 0.004; anxiety difference 1.30 ± 0.22; p < 0.001). Patients experienced more pain (1.05 ± 0.12; p < 0.001) and anxiety (1.22 ± 0.15; p < 0.001) after placement of IMD. Radiographers are more cautious, more anxious and use less compression during mammography of breasts with IMD. Image quality in a breast with an IMD could be improved by projecting more breast tissue on the mammogram, thereby including (part of) the IMD between the paddles, if required. In addition, radiographers should pay sufficient attention to reducing discomfort both before and during the screening examination. Little is known about the quality of mammography in females with an IMD or how these females and radiographers experience the screening

  8. Slit-scanning differential phase-contrast mammography: first experimental results

    NASA Astrophysics Data System (ADS)

    Roessl, Ewald; Daerr, Heiner; Koehler, Thomas; Martens, Gerhard; van Stevendaal, Udo

    2014-03-01

    The demands for a large field-of-view (FOV) and the stringent requirements for a stable acquisition geometry rank among the major obstacles for the translation of grating-based, differential phase-contrast techniques from the laboratory to clinical applications. While for state-of-the-art Full-Field-Digital Mammography (FFDM) FOVs of 24 cm x 30 cm are common practice, the specifications for mechanical stability are naturally derived from the detector pixel size which ranges between 50 and 100 μm. However, in grating-based, phasecontrast imaging, the relative placement of the gratings in the interferometer must be guaranteed to within micro-meter precision. In this work we report on first experimental results on a phase-contrast x-ray imaging system based on the Philips MicroDose L30 mammography unit. With the proposed approach we achieve a FOV of about 65 mm x 175 mm by the use of the slit-scanning technique. The demand for mechanical stability on a micrometer scale was relaxed by the specific interferometer design, i.e., a rigid, actuator-free mount of the phase-grating G1 with respect to the analyzer-grating G2 onto a common steel frame. The image acquisition and formation processes are described and first phase-contrast images of a test object are presented. A brief discussion of the shortcomings of the current approach is given, including the level of remaining image artifacts and the relatively inefficient usage of the total available x-ray source output.

  9. [Exploring a non-inflammatory clinical breast mass: Clinical practice guidelines].

    PubMed

    Legendre, G; Guilhen, N; Nadeau, C; Brossard, A; Fauvet, R

    2015-12-01

    The aim of the study was to assess the diagnostic value of physical examination, radiologic explorations and percutaneous procedures of the breast in the exploration of a non-inflammatory palpable mass, in order to propose guidelines. A systematic literature review was conducted in the Medline and Cochrane library databases. International guidelines in French and English language were also consulted until April 30th 2015. Physical examination of a non-inflammatory palpable breast mass is not sufficient to eliminate a breast cancer (LE2). Mammography alone has a sensitivity between 70 and 95% for the diagnosis of breast cancer (LE3). Echography alone has a sensitivity of 98 to 100% for the diagnosis of breast cancer (LE2). The core needle biopsy has a better sensitivity and specificity than the fine-needle aspiration for breast cancer diagnosis (LE2). The association of mammography and 2D echography presents excellent sensitivity and negative predictive value (close to 100 %) to exclude a breast cancer (LE3). A double evaluation using mammography and echography is recommended in the exploration of a non-inflammatory palpable breast mass (grade B). Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Added Value of Contrast-Enhanced Spectral Mammography in Postscreening Assessment.

    PubMed

    Tardivel, Anne-Marie; Balleyguier, Corinne; Dunant, Ariane; Delaloge, Suzette; Mazouni, Chafika; Mathieu, Marie-Christine; Dromain, Clarisse

    2016-09-01

    To assess the value on diagnostic and treatment management of contrast-enhanced spectral mammography (CESM), as adjunct to mammography (MG) and ultrasound (US) in postscreening in a breast cancer unit for patients with newly diagnosed breast cancer or with suspicious findings on conventional imaging. Retrospective review of routine use of bilateral CESM performed between September 2012 and September 2013 in 195 women with suspicious or undetermined findings on MG and/or US. CESM images were blindly reviewed by two radiologists for BI-RADS(®) assessment and probability of malignancy. Each lesion was definitely confirmed either with histopathology or follow-up. Two hundred and ninety-nine lesions were detected (221 malignant). CESM sensitivity, specificity, positive-predictive value and negative-predictive value were 94% (CI: 89-96%), 74% (CI: 63-83%), 91% (CI: 86-94%) and 81% (CI: 70-89%), respectively, with 18 false positive and 14 false negative. CESM changed diagnostic and treatment strategy in 41 (21%) patients either after detection of additional malignant lesions in 38 patients (19%)-with a more extensive surgery (n = 21) or neo-adjuvant chemotherapy (n = 1)-or avoiding further biopsy for 20 patients with negative CESM. CESM can be performed easily in a clinical assessment after positive breast cancer screening and may change significantly the diagnostic and treatment strategy through breast cancer staging. © 2016 Wiley Periodicals, Inc.

  11. Adding the power of iodinated contrast media to the credibility of mammography in breast cancer diagnosis

    PubMed Central

    Tsigginou, Alexandra; Chalazonitis, Athanasios; Feida, Eleni; Vlachos, Dimitrios Efthymios; Zagouri, Flora; Rellias, Ioannis; Dimitrakakis, Constantine

    2016-01-01

    Dual-energy contrast-enhanced spectral mammography (CESM) represents a relatively new diagnostic tool adjunct to mammography. The aim of this study was to strengthen the breast imaging-reporting and data system (BIRADS) classification score in order to improve early breast cancer diagnosis. For this reason, we propose a sum score, termed malignancy potential score (MPS), incorporating the standard BIRADS score and our proposed CESM score. From September 2014 to September 2015, 216 females (age range, 26–85 years; mean age 54.6 years) underwent CESM evaluation of mammographic findings that were primarily assessed as BIRADS 2–5. 10 of these patients had bilateral findings; a total of 226 lesions were examined. High-energy image evaluation was based on the intensity of contrast enhancement of the lesion compared with background enhancement, categorized as Type -1, 0, 1 or 2 enhancement. Histopathology reports were compared with imaging assessment. 98 of 226 lesions were malignant and 128 of 226 lesions were benign. The area under the curve was 0.843, 0.888 and 0.917 for mammographic BIRADS score, CESM score and MPS, respectively, with p-value < 0.05. The sensitivity, specificity and accuracy rates were 91.83, 80.47 and 85.40%, respectively, when a best MPS cut-off point of 4 was used. The malignancy potential score (MPS) has higher diagnostic performance than digital mammography or CESM alone. MPS empowers the credibility of the digital mammography BIRADS score and our proposed type of enhancement in dual-energy CESM and is a diagnostic tool that increases the accuracy rate in early breast cancer diagnosis. PMID:27452266

  12. Conflicting national recommendations and the use of screening mammography: does the physician's recommendation matter?

    PubMed

    Taplin, S H; Urban, N; Taylor, V M; Savarino, J

    1997-01-01

    This study evaluated whether women's perceptions of the conflicting recommendations for breast cancer screening were associated with decreased use of mammography. We conducted a random-digit-dial telephone survey of 1024 women in four communities of western Washington State. In addition to collecting data for demographics, beliefs about mammography, and insurance coverage, we inquired whether the respondents were aware of any conflicting recommendations about when to begin or how frequently to perform screening mammography, whether their physicians had recommended a mammogram, and whether they were likely to do what their physicians recommended. After grouping women according to whether they perceived conflicting recommendations, we used chi-square statistics to compare the distribution of proportions of women by age, race, household income, education, and insurance coverage. To estimate the odds of their having a mammogram in the previous 2 years (yes or no), we used multivariate logistic regression and included the above variables as covariates. Sixty-two percent of eligible women completed the survey, and 49 percent (479 of 985) perceived conflicting recommendations. The association between perceiving conflict and mammography use was not significant. Eighty-three percent of women who perceived conflicting recommendations reported being more comfortable using their own judgment about getting the procedure. After controlling for whether women perceived conflicting recommendations and all other factors, women who said they followed their physician's advice but did not recall their physician recommending mammography were 71 percent less likely to have received a recent mammogram than were women who reported their physician did recommend it (odds ratio 0.29, confidence interval 0.16-0.51). The conflicting recommendations surrounding breast cancer screening are not influencing women's choices about mammography. The physician recommendation and women's self

  13. Dual-energy digital mammography for calcification imaging: scatter and nonuniformity corrections.

    PubMed

    Kappadath, S Cheenu; Shaw, Chris C

    2005-11-01

    Mammographic images of small calcifications, which are often the earliest signs of breast cancer, can be obscured by overlapping fibroglandular tissue. We have developed and implemented a dual-energy digital mammography (DEDM) technique for calcification imaging under full-field imaging conditions using a commercially available aSi:H/CsI:Tl flat-panel based digital mammography system. The low- and high-energy images were combined using a nonlinear mapping function to cancel the tissue structures and generate the dual-energy (DE) calcification images. The total entrance-skin exposure and mean-glandular dose from the low- and high-energy images were constrained so that they were similar to screening-examination levels. To evaluate the DE calcification image, we designed a phantom using calcium carbonate crystals to simulate calcifications of various sizes (212-425 microm) overlaid with breast-tissue-equivalent material 5 cm thick with a continuously varying glandular-tissue ratio from 0% to 100%. We report on the effects of scatter radiation and nonuniformity in x-ray intensity and detector response on the DE calcification images. The nonuniformity was corrected by normalizing the low- and high-energy images with full-field reference images. Correction of scatter in the low- and high-energy images significantly reduced the background signal in the DE calcification image. Under the current implementation of DEDM, utilizing the mammography system and dose level tested, calcifications in the 300-355 microm size range were clearly visible in DE calcification images. Calcification threshold sizes decreased to the 250-280 microm size range when the visibility criteria were lowered to barely visible. Calcifications smaller than approximately 250 microm were usually not visible in most cases. The visibility of calcifications with our DEDM imaging technique was limited by quantum noise, not system noise.

  14. Dual-energy digital mammography for calcification imaging: Scatter and nonuniformity corrections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kappadath, S. Cheenu; Shaw, Chris C.

    Mammographic images of small calcifications, which are often the earliest signs of breast cancer, can be obscured by overlapping fibroglandular tissue. We have developed and implemented a dual-energy digital mammography (DEDM) technique for calcification imaging under full-field imaging conditions using a commercially available aSi:H/CsI:Tl flat-panel based digital mammography system. The low- and high-energy images were combined using a nonlinear mapping function to cancel the tissue structures and generate the dual-energy (DE) calcification images. The total entrance-skin exposure and mean-glandular dose from the low- and high-energy images were constrained so that they were similar to screening-examination levels. To evaluate the DEmore » calcification image, we designed a phantom using calcium carbonate crystals to simulate calcifications of various sizes (212-425 {mu}m) overlaid with breast-tissue-equivalent material 5 cm thick with a continuously varying glandular-tissue ratio from 0% to 100%. We report on the effects of scatter radiation and nonuniformity in x-ray intensity and detector response on the DE calcification images. The nonuniformity was corrected by normalizing the low- and high-energy images with full-field reference images. Correction of scatter in the low- and high-energy images significantly reduced the background signal in the DE calcification image. Under the current implementation of DEDM, utilizing the mammography system and dose level tested, calcifications in the 300-355 {mu}m size range were clearly visible in DE calcification images. Calcification threshold sizes decreased to the 250-280 {mu}m size range when the visibility criteria were lowered to barely visible. Calcifications smaller than {approx}250 {mu}m were usually not visible in most cases. The visibility of calcifications with our DEDM imaging technique was limited by quantum noise, not system noise.« less

  15. Multiparameter optimization of mammography: an update

    NASA Astrophysics Data System (ADS)

    Jafroudi, Hamid; Muntz, E. P.; Jennings, Robert J.

    1994-05-01

    Previously in this forum we have reported the application of multiparameter optimization techniques to the design of a minimum dose mammography system. The approach used a reference system to define the physical imaging performance required and the dose to which the dose for the optimized system should be compared. During the course of implementing the resulting design in hardware suitable for laboratory testing, the state of the art in mammographic imaging changed, so that the original reference system, which did not have a grid, was no longer appropriate. A reference system with a grid was selected in response to this change, and at the same time the optimization procedure was modified, to make it more general and to facilitate study of the optimized design under a variety of conditions. We report the changes in the procedure, and the results obtained using the revised procedure and the up- to-date reference system. Our results, which are supported by laboratory measurements, indicate that the optimized design can image small objects as well as the reference system using only about 30% of the dose required by the reference system. Hardware meeting the specification produced by the optimization procedure and suitable for clinical use is currently under evaluation in the Diagnostic Radiology Department at the Clinical Center, NH.

  16. FDA & digital mammography: why has FDA required full field digital mammography systems to be regulated as potentially dangerous devices for more than 10 years?

    PubMed

    Nields, Morgan W

    2010-05-01

    Digital mammography is routinely used in the US to screen asymptomatic women for breast cancer and currently over 50% of US screening centers employ the technology. In spite of FDAs knowledge that digital mammography requires less radiation than film mammography and that its equivalence has been proven in a prospective randomized trial, the agency has failed to allow the technology market access via the 510(k) pre market clearance pathway. As a result of the restrictive Pre Market Approval process, only four suppliers have received FDA approval. The resulting lack of a competitive market has kept costs high, restricted technological innovation, and impeded product improvements as a result of PMA requirements. Meanwhile, at least twelve companies are on the market in the EU and the resulting competitive market has lowered costs and provided increased technological choice. A cultural change with new leadership occurred in the early 90's at FDA. The historical culture at the Center for Devices and Radiological Health of collaboration and education gave way to one characterized by a lack of reliance on outside scientific expertise, tolerance of decision making by unqualified reviewers, and an emphasis on enforcement and punishment. Digital mammography fell victim to this cultural change and as a result major innovations like breast CT and computer aided detection technologies are also withheld from the market. The medical device law, currently under review by the Institute of Medicine, should be amended by the Congress so that new technologies can be appropriately classified in accordance with the risk based assessment classification system detailed in Chapter V of the Federal Food, Drug, and Cosmetic Act. A panel of scientific experts chartered by the NIH or IOM should determine the classification appropriate for new technologies that have no historical regulatory framework. This would be binding on FDA. Unless the law is changed we will likely again experience

  17. Radiological and clinical features of adult non-puerperal mastitis.

    PubMed

    Tan, H; Li, R; Peng, W; Liu, H; Gu, Y; Shen, X

    2013-04-01

    To describe the radiological and clinical features of adult non-puerperal mastitis and to determine the most accurate method of preventing unnecessary surgical procedures. Clinical and imaging findings were retrospectively reviewed in 51 females with non-puerperal mastitis, which was confirmed by biopsy/surgical pathology. All 51 patients had pre-operative MRI; 45 patients also had sonograms and 25 also had mammograms, pre-operatively. Of the 51 cases with non-puerperal mastitis, 94.1% (48/51) were confirmed as having acute or chronic inflammation, and the other 3 had plasma cell mastitis; areola papillaris inflammation was found in 39.2% (20/51) of the cases. Overall, 6 of the 25 cases that were examined with mammography and 2 of the 45 cases that were examined with sonography appeared normal, but all 51 lesions were positively identified on MRI. Asymmetrical density (12/25) on mammograms and solitary or separated/contiguous, clustered, hypoechoic mass-like lesions (31/45) on ultrasound were the most common signs of non-puerperal mastitis. On enhanced MRI, 90.2% (46/51) of patients showed non-mass-like enhanced lesions. Multiple regional enhancements in the pattern of distribution (32/46) and separated or contiguous, clustered, rim-like enhancements in the pattern of internal enhancement (29/46) were the most common manifestations in non-mass-like enhanced lesions. Of the 51 patients, mastitis Type 1 and Type 2 in the time-signal intensity curve were detected in 47.1% and 51.0% of the patients, respectively. The breast imaging reporting and data system categories with the highest number of patients were Category 0 (9/25) on mammography, Category 4a on sonography (18/45) and Category 4a on MRI (29/51). The findings from mammography and ultrasound are non-specific; therefore, using MR can be helpful in the diagnosis, especially in the presence of non-mass-like enhancements that are multiple, regional, separated, or contiguous, clustered and rim-like. Mastitis is

  18. Comparison of Two Different Educational Methods for Teachers' Mammography Based on the Health Belief Model.

    PubMed

    Heydari, Esmat; Noroozi, Azita

    2015-01-01

    Breast cancer is the most common cancer in women. One way to decrease the burden of this cancer is early detection through mammography. This study compared the effectiveness of two different educational methods for teachers' uptake of mammography based on the Health Belief Model. The current study was a randomised trial of 120 teachers over 40 years old in two groups receiving multimedia or group education, both based on the Health Belief Model. Participants completed questionnaires before, immediately and three months after educational intervention. Mammography was evaluated before and after educational intervention. The participants in the two groups were demographically similar. Comparison showed no difference noted in the scores of knowledge, perceived barriers, susceptibility, and severity constructs between two groups (p > 0.05). Health motivation and benefit were perceived to be higher in the group education compared to the multimedia group. There was a significant difference in mammography between two groups after the intervention (p= 0.003). Planning and implementation of educational program based on the Health Belief Model can raise knowledge and increase participation in mammography especially with group education.

  19. Cost-Effectiveness of Three Rounds of Mammography Breast Cancer Screening in Iranian Women

    PubMed Central

    Haghighat, Shahpar; Akbari, Mohammad Esmaeil; Yavari, Parvin; Javanbakht, Mehdi; Ghaffari, Shahram

    2016-01-01

    Background Breast cancer is the most common cancer in Iranian women as is worldwide. Mammography screening has been introduced as a beneficial method for reducing mortality and morbidity of this disease. Objectives We developed an analytical model to assess the cost effectiveness of an organized mammography screening program in Iran for early detection of the breast cancer. Patients and Methods This study is an economic evaluation of mammography screening program among Iranian woman aged 40 - 70 years. A decision tree and Markov model were applied to estimate total quality adjusted life years (QALY) and lifetime costs. Results The results revealed that the incremental cost effectiveness ratio (ICER) of mammography screening in Iranian women in the first round was Int. $ 37,350 per QALY gained. The model showed that the ICER in the second and third rounds of screening program were Int. $ 141,641 and Int. $ 389,148 respectively. Conclusions Study results identified that mammography screening program was cost-effective in 53% of the cases, but incremental cost per QALY in the second and third rounds of screening are much higher than the accepted payment threshold of Iranian health system. Thus, evaluation of other screening strategies would be useful to identify more cost-effective program. Future studies with new national data can improve the accuracy of our finding and provide better information for health policy makers for decision making. PMID:27366315

  20. Dissemination of periodic mammography and patterns of use, by birth cohort, in Catalonia (Spain)

    PubMed Central

    Rue, Montserrat; Carles, Misericordia; Vilaprinyo, Ester; Martinez-Alonso, Montserrat; Espinas, Josep-Alfons; Pla, Roger; Brugulat, Pilar

    2008-01-01

    Background In Catalonia (Spain) breast cancer mortality has declined since the beginning of the 1990s. The dissemination of early detection by mammography and the introduction of adjuvant treatments are among the possible causes of this decrease, and both were almost coincident in time. Thus, understanding how these procedures were incorporated into use in the general population and in women diagnosed with breast cancer is very important for assessing their contribution to the reduction in breast cancer mortality. In this work we have modeled the dissemination of periodic mammography and described repeat mammography behavior in Catalonia from 1975 to 2006. Methods Cross-sectional data from three Catalan Health Surveys for the calendar years 1994, 2002 and 2006 was used. The dissemination of mammography by birth cohort was modeled using a mixed effects model and repeat mammography behavior was described by age and survey year. Results For women born from 1938 to 1952, mammography clearly had a period effect, meaning that they started to have periodic mammograms at the same calendar years but at different ages. The age at which approximately 50% of the women were receiving periodic mammograms went from 57.8 years of age for women born in 1938–1942 to 37.3 years of age for women born in 1963–1967. Women in all age groups experienced an increase in periodic mammography use over time, although women in the 50–69 age group have experienced the highest increase. Currently, the target population of the Catalan Breast Cancer Screening Program, 50–69 years of age, is the group that self-reports the highest utilization of periodic mammograms, followed by the 40–49 age group. A higher proportion of women of all age groups have annual mammograms rather than biennial or irregular ones. Conclusion Mammography in Catalonia became more widely implemented during the 1990s. We estimated when cohorts initiated periodic mammograms and how frequently women are receiving them

  1. Mammography Adherence in African-American Women: Results of a Randomized Controlled Trial.

    PubMed

    Gathirua-Mwangi, Wambui G; Monahan, Patrick O; Stump, Timothy; Rawl, Susan M; Skinner, Celette Sugg; Champion, Victoria L

    2016-02-01

    Breast cancer is the second leading cause of cancer mortality among women in the developed world. Mammography screening is especially important for African-Americans because they experience a greater mortality (OR = 1.38) than Caucasians despite having a lower incidence of breast cancer. The purpose of this study was to compare the effects of two interventions with usual care on mammography adherence among African-American women. A subsample of African-American women (n = 244) aged 41-65 years who had not had a mammogram in the last 15 months and no history of breast cancer was randomly assigned to receive (1) mailed interactive DVD, (2) computer-tailored telephone counseling, or (3) usual care. The DVD intervention was five times more effective than usual care for promoting mammography screening at 6 months follow-up among women who earned less than $30,000 (OR = 5.3). Compared to usual care, neither the DVD nor phone produced significant effects for women with household incomes >$30,000. Use of a mailed DVD for low-income African-American women may be an effective way to increase mammography adherence.

  2. Pictorial essay: Mammography of the male breast

    PubMed Central

    Popli, Manju Bala; Popli, V; Bahl, P; Solanki, Y

    2009-01-01

    Mammography is an imaging modality that is widely perceived to be of use only in women for the detection and diagnosis of breast pathologies. Here, we present a pictorial essay on the mammographic spectrum of male breast pathologies. PMID:19881102

  3. Image segmentation and 3D visualization for MRI mammography

    NASA Astrophysics Data System (ADS)

    Li, Lihua; Chu, Yong; Salem, Angela F.; Clark, Robert A.

    2002-05-01

    MRI mammography has a number of advantages, including the tomographic, and therefore three-dimensional (3-D) nature, of the images. It allows the application of MRI mammography to breasts with dense tissue, post operative scarring, and silicon implants. However, due to the vast quantity of images and subtlety of difference in MR sequence, there is a need for reliable computer diagnosis to reduce the radiologist's workload. The purpose of this work was to develop automatic breast/tissue segmentation and visualization algorithms to aid physicians in detecting and observing abnormalities in breast. Two segmentation algorithms were developed: one for breast segmentation, the other for glandular tissue segmentation. In breast segmentation, the MRI image is first segmented using an adaptive growing clustering method. Two tracing algorithms were then developed to refine the breast air and chest wall boundaries of breast. The glandular tissue segmentation was performed using an adaptive thresholding method, in which the threshold value was spatially adaptive using a sliding window. The 3D visualization of the segmented 2D slices of MRI mammography was implemented under IDL environment. The breast and glandular tissue rendering, slicing and animation were displayed.

  4. Configuration of automatic exposure control on mammography units for computed radiography to match patient dose of screen film systems

    NASA Astrophysics Data System (ADS)

    Yang, Chang-Ying Joseph; Huang, Weidong

    2009-02-01

    Computed radiography (CR) is considered a drop-in addition or replacement for traditional screen-film (SF) systems in digital mammography. Unlike other technologies, CR has the advantage of being compatible with existing mammography units. One of the challenges, however, is to properly configure the automatic exposure control (AEC) on existing mammography units for CR use. Unlike analogue systems, the capture and display of digital CR images is decoupled. The function of AEC is changed from ensuring proper and consistent optical density of the captured image on film to balancing image quality with patient dose needed for CR. One of the preferences when acquiring CR images under AEC is to use the same patient dose as SF systems. The challenge is whether the existing AEC design and calibration process-most of them proprietary from the X-ray systems manufacturers and tailored specifically for SF response properties-can be adapted for CR cassettes, in order to compensate for their response and attenuation differences. This paper describes the methods for configuring the AEC of three different mammography units models to match the patient dose used for CR with those that are used for a KODAK MIN-R 2000 SF System. Based on phantom test results, these methods provide the dose level under AEC for the CR systems to match with the dose of SF systems. These methods can be used in clinical environments that require the acquisition of CR images under AEC at the same dose levels as those used for SF systems.

  5. Comparison of Breast Density Between Synthesized Versus Standard Digital Mammography.

    PubMed

    Haider, Irfanullah; Morgan, Matthew; McGow, Anna; Stein, Matthew; Rezvani, Maryam; Freer, Phoebe; Hu, Nan; Fajardo, Laurie; Winkler, Nicole

    2018-06-12

    To evaluate perceptual difference in breast density classification using synthesized mammography (SM) compared with standard or full-field digital mammography (FFDM) for screening. This institutional review board-approved, retrospective, multireader study evaluated breast density on 200 patients who underwent baseline screening mammogram during which both SM and FFDM were obtained contemporaneously from June 1, 2016, through November 30, 2016. Qualitative breast density was independently assigned by seven readers initially evaluating FFDM alone. Then, in a separate session, these same readers assigned breast density using synthetic views alone on the same 200 patients. The readers were again blinded to each other's assignment. Qualitative density assessment was based on BI-RADS fifth edition. Interreader agreement was evaluated with κ statistic using 95% confidence intervals. Testing for homogeneity in paired proportions was performed using McNemar's test with a level of significance of .05. For patients across the SM and standard 2-D data set, diagnostic testing with McNemar's test with P = 0.32 demonstrates that the minimal density transitions across FFDM and SM are not statistically significant density shifts. Taking clinical significance into account, only 8 of 200 (4%) patients had clinically significant transition (dense versus not dense). There was substantial interreader agreement with overall κ in FFDM of 0.71 (minimum 0.53, maximum 0.81) and overall SM κ average of 0.63 (minimum 0.56, maximum 0.87). Overall subjective breast density assignment by radiologists on SM is similar to density assignment on standard 2-D mammogram. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia.

    PubMed

    Chen, Po-Hao; Slanetz, Priscilla J

    2014-01-01

    To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. A total of 353 mammograms were obtained from 327 unique patients (ages 18-95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Comparison between breast MRI and contrast-enhanced spectral mammography.

    PubMed

    Łuczyńska, Elżbieta; Heinze-Paluchowska, Sylwia; Hendrick, Edward; Dyczek, Sonia; Ryś, Janusz; Herman, Krzysztof; Blecharz, Paweł; Jakubowicz, Jerzy

    2015-05-12

    The main goal of this study was to compare contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) with histopathological results and to compare the sensitivity, accuracy, and positive and negative predictive values for both imaging modalities. After ethics approval, CESM and MRI examinations were performed in 102 patients who had suspicious lesions described in conventional mammography. All visible lesions were evaluated independently by 2 experienced radiologists using BI-RADS classifications (scale 1-5). Dimensions of lesions measured with each modality were compared to postoperative histopathology results. There were 102 patients entered into CESM/MRI studies and 118 lesions were identified by the combination of CESM and breast MRI. Histopathology confirmed that 81 of 118 lesions were malignant and 37 were benign. Of the 81 malignant lesions, 72 were invasive cancers and 9 were in situ cancers. Sensitivity was 100% with CESM and 93% with breast MRI. Accuracy was 79% with CESM and 73% with breast MRI. ROC curve areas based on BI-RADS were 0.83 for CESM and 0.84 for breast MRI. Lesion size estimates on CESM and breast MRI were similar, both slightly larger than those from histopathology. Our results indicate that CESM has the potential to be a valuable diagnostic method that enables accurate detection of malignant breast lesions, has high negative predictive value, and a false-positive rate similar to that of breast MRI.

  8. Comparison between Breast MRI and Contrast-Enhanced Spectral Mammography

    PubMed Central

    Łuczyńska, Elżbieta; Heinze-Paluchowska, Sylwia; Hendrick, Edward; Dyczek, Sonia; Ryś, Janusz; Herman, Krzysztof; Blecharz, Paweł; Jakubowicz, Jerzy

    2015-01-01

    Background The main goal of this study was to compare contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) with histopathological results and to compare the sensitivity, accuracy, and positive and negative predictive values for both imaging modalities. Material/Methods After ethics approval, CESM and MRI examinations were performed in 102 patients who had suspicious lesions described in conventional mammography. All visible lesions were evaluated independently by 2 experienced radiologists using BI-RADS classifications (scale 1–5). Dimensions of lesions measured with each modality were compared to postoperative histopathology results. Results There were 102 patients entered into CESM/MRI studies and 118 lesions were identified by the combination of CESM and breast MRI. Histopathology confirmed that 81 of 118 lesions were malignant and 37 were benign. Of the 81 malignant lesions, 72 were invasive cancers and 9 were in situ cancers. Sensitivity was 100% with CESM and 93% with breast MRI. Accuracy was 79% with CESM and 73% with breast MRI. ROC curve areas based on BI-RADS were 0.83 for CESM and 0.84 for breast MRI. Lesion size estimates on CESM and breast MRI were similar, both slightly larger than those from histopathology. Conclusions Our results indicate that CESM has the potential to be a valuable diagnostic method that enables accurate detection of malignant breast lesions, has high negative predictive value, and a false-positive rate similar to that of breast MRI. PMID:25963880

  9. Clinical examiners, simulated patients, and student self-assessed empathy in medical students during a psychiatry objective structured clinical examination.

    PubMed

    O'Connor, Karen; King, Romaine; Malone, Kevin M; Guerandel, Allys

    2014-08-01

    This study aims to assess and compare objective and subjective scores of empathy in final-year medical students by using firstly a validated student self-assessment just prior to the psychiatry objective structured clinical examination (OSCE), and then comparing this to clinical examiner's and simulated patient's (SP's) assessments of empathy of students using a Global Rating of Empathy scale (GRE) during a psychiatry OSCE. In 2011, all final-year medical students in the University College Dublin were invited to complete a subjective, self-assessed empathy questionnaire (The Jefferson scale of physician empathy-student version (JSPE-S)). They were also assessed for empathy in four OSCEs by the clinical examiner and the SP acting in that OSCE scenario. Included in the analysis were 163 of 184 final-year students JSPE-S (88.6%) questionnaires. The female students scores on the JSPE-S were significantly higher than those of their male peers (t=3.34, p=0.001). Concurrent validity was greater between the SPs' assessments of empathy in the OSCE and the JSPE-S score than between the clinical examiners assessments of empathy and the JSPE-S score (r=0.23, p<0.005; r=0.14, p<0.08). Inter-rater reliability of SP's and clinical examiner's using the GRE was found to be high (F=0.868 (df=171, 171), p value<0.001). SPs may be valid assessors of empathy in medical students during an OSCE.

  10. [What kind of information do German health information pamphlets provide on mammography screening?].

    PubMed

    Kurzenhäuser, Stephanie

    2003-02-01

    To make an informed decision on participation in mammography screening, women have to be educated about all the risks and benefits of the procedure in a manner that is detailed and understandable. But an analysis of 27 German health pamphlets on mammography screening shows that many relevant pieces of information about the benefits, the risks, and especially the meaning of screening results are only insufficiently communicated. Many statements were presented narratively rather than as precise statistics. Depending on content, 17 to 62% of the quantifiable statements were actually given as numerical data. To provide comprehensive information and to avoid misunderstandings, it is necessary to supplement the currently available health pamphlets and make the information on mammography screening more precise.

  11. The influence of travel time on breast cancer characteristics, receipt of primary therapy, and surveillance mammography.

    PubMed

    Onega, Tracy; Cook, Andrea; Kirlin, Beth; Shi, Xun; Alford-Teaster, Jennifer; Tuzzio, Leah; Buist, Diana S M

    2011-08-01

    Travel time has been shown to influence some aspects of cancer characteristics at diagnosis and care for women with breast cancer, but important gaps remain in our understanding of its impact. We examined the influence of travel time to the nearest radiology facility on breast cancer characteristics, treatment, and surveillance for women with early-stage invasive breast cancer. We included 1,012 women with invasive breast cancer (stages I and II) who had access to care within an integrated health care delivery system in western Washington State. The travel times to the nearest radiology facility were calculated for all the U.S. Census blocks within the study area and assigned to women based on residence at diagnosis. We collected cancer characteristics, primary and adjuvant therapies, and surveillance mammography for at least 2.5 years post diagnosis and used multivariable analyses to test the associations of travel time. The majority of women (68.6%) lived within 20 min of the nearest radiology facility, had stage I disease (72.7%), received breast conserving therapy (68.7%), and had annual surveillance mammography the first 2 years after treatment (73.7%). The travel time was not significantly associated with the stage or surveillance mammography after adjusting for covariates. Primary therapy was significantly related to travel time, with greater travel time (>30 min vs. ≤ 10 min) associated with a higher likelihood of mastectomy compared to breast conserving surgery (RR = 1.53; 95% CI, 1.16-2.01). The travel time was not associated with the stage at diagnosis or surveillance mammography receipt. The travel time does seem to influence the type of primary therapy among women with breast cancer, suggesting that women may prefer low frequency services, such as mastectomy, if geographic access to a radiology facility is limited.

  12. The influence of travel time on breast cancer characteristics, receipt of primary therapy, and surveillance mammography

    PubMed Central

    Cook, Andrea; Kirlin, Beth; Shi, Xun; Alford-Teaster, Jennifer; Tuzzio, Leah; Buist, Diana S. M.

    2013-01-01

    Travel time has been shown to influence some aspects of cancer characteristics at diagnosis and care for women with breast cancer, but important gaps remain in our understanding of its impact. We examined the influence of travel time to the nearest radiology facility on breast cancer characteristics, treatment, and surveillance for women with early-stage invasive breast cancer. We included 1,012 women with invasive breast cancer (stages I and II) who had access to care within an integrated health care delivery system in western Washington State. The travel times to the nearest radiology facility were calculated for all the U.S. Census blocks within the study area and assigned to women based on residence at diagnosis. We collected cancer characteristics, primary and adjuvant therapies, and surveillance mammography for at least 2.5 years post diagnosis and used multivariable analyses to test the associations of travel time. The majority of women (68.6%) lived within 20 min of the nearest radiology facility, had stage I disease (72.7%), received breast conserving therapy (68.7%), and had annual surveillance mammography the first 2 years after treatment (73.7%). The travel time was not significantly associated with the stage or surveillance mammography after adjusting for covariates. Primary therapy was significantly related to travel time, with greater travel time (>30 min vs. ≤ 10 min) associated with a higher likelihood of mastectomy compared to breast conserving surgery (RR = 1.53; 95% CI, 1.16–2.01). The travel time was not associated with the stage at diagnosis or surveillance mammography receipt. The travel time does seem to influence the type of primary therapy among women with breast cancer, suggesting that women may prefer low frequency services, such as mastectomy, if geographic access to a radiology facility is limited. PMID:21553117

  13. The influence of software filtering in digital mammography image quality

    NASA Astrophysics Data System (ADS)

    Michail, C.; Spyropoulou, V.; Kalyvas, N.; Valais, I.; Dimitropoulos, N.; Fountos, G.; Kandarakis, I.; Panayiotakis, G.

    2009-05-01

    Breast cancer is one of the most frequently diagnosed cancers among women. Several techniques have been developed to help in the early detection of breast cancer such as conventional and digital x-ray mammography, positron and single-photon emission mammography, etc. A key advantage in digital mammography is that images can be manipulated as simple computer image files. Thus non-dedicated commercially available image manipulation software can be employed to process and store the images. The image processing tools of the Photoshop (CS 2) software usually incorporate digital filters which may be used to reduce image noise, enhance contrast and increase spatial resolution. However, improving an image quality parameter may result in degradation of another. The aim of this work was to investigate the influence of three sharpening filters, named hereafter sharpen, sharpen more and sharpen edges on image resolution and noise. Image resolution was assessed by means of the Modulation Transfer Function (MTF).In conclusion it was found that the correct use of commercial non-dedicated software on digital mammograms may improve some aspects of image quality.

  14. Magnetic Resonance Imaging as an Adjunct to Mammography for Breast Cancer Screening in Women at Less Than High Risk for Breast Cancer: A Health Technology Assessment

    PubMed Central

    Nikitovic-Jokic, Milica; Holubowich, Corinne

    2016-01-01

    Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Among women at high risk for breast cancer, magnetic resonance imaging (MRI) has been suggested as a safe adjunct (supplemental) screening tool that can detect breast cancers missed on screening mammography, potentially reducing the number of deaths associated with the disease. However, the use of adjunct screening tests may also increase the number of false-positive test results, which may lead to unnecessary follow-up testing, as well as patient stress and anxiety. We investigated the benefits and harms of MRI as an adjunct to mammography compared with mammography alone for screening women at less than high risk (average or higher than average risk) for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects (DARE), Centre for Reviews and Dissemination (CRD) Health Technology Assessment Database, and National Health Service (NHS) Economic Evaluation Database, from January 2002 to January 2016, for evidence of effectiveness, harms, and diagnostic accuracy. Only studies evaluating the use of screening breast MRI as an adjunct to mammography in the specified populations were included. Results No studies in women at less than high risk for breast cancer met our inclusion criteria. Conclusions It remains uncertain if the use of adjunct screening breast MRI in women at less than high risk (average or higher than average risk) for breast cancer will reduce breast cancer–related mortality without significant increases in unnecessary follow-up testing and treatment. PMID:27990198

  15. Reduction in interval cancer rates following the introduction of two-view mammography in the UK breast screening programme

    PubMed Central

    Dibden, A; Offman, J; Parmar, D; Jenkins, J; Slater, J; Binysh, K; McSorley, J; Scorfield, S; Cumming, P; Liao, X-H; Ryan, M; Harker, D; Stevens, G; Rogers, N; Blanks, R; Sellars, S; Patnick, J; Duffy, S W

    2014-01-01

    Background: The introduction of two-view mammography at incident (subsequent) screens in the National Health Service Breast Screening Programme (NHSBSP) has led to an increased number of cancers detected at screen. However, the effect of two-view mammography on interval cancer rates has yet to be assessed. Methods: Routine screening and interval cancer data were collated from all screening programmes in the United Kingdom for women aged 50–64, screened between 1 April 2003 and 31 March 2005. Interval cancer rates were compared based on whether two-view mammography was in use at the last routine screen. Results: The reduction in interval cancers following screening using two-view mammography compared with one view was 0.68 per 1 000 women screened. Overall, this suggests the introduction of two-view mammography at incident screen was accompanied by a 15–20% reduction in interval cancer rates in the NHSBSP. Conclusion: The introduction of two-view mammography at incident screens is associated with a reduction in incidence of interval cancers. This is consistent with previous publications on a contemporaneous increase in screen-detected cancers. The results provide further evidence of the benefit of the use of two-view mammography at incident screens. PMID:24366303

  16. Adherence to Mammography Screening Guidelines Among Transgender Persons and Sexual Minority Women.

    PubMed

    Bazzi, Angela Robertson; Whorms, Debra S; King, Dana S; Potter, Jennifer

    2015-11-01

    We used retrospective (2012-2013) chart review to examine breast cancer screening among transgender persons and sexual minority women (n = 1263) attending an urban community health center in Massachusetts. Transgender were less likely than cisgender patients and bisexuals were less likely than heterosexuals and lesbians to adhere to mammography screening guidelines (respectively, adjusted odds ratios = 0.53 and 0.56; 95% confidence intervals = 0.31, 0.91 and 0.34, 0.92) after adjustment for sociodemographics. Enhanced cancer prevention outreach is needed among gender and sexual minorities.

  17. Contrast-enhanced spectral mammography with a photon-counting detector.

    PubMed

    Fredenberg, Erik; Hemmendorff, Magnus; Cederström, Björn; Aslund, Magnus; Danielsson, Mats

    2010-05-01

    Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another approximately 70%-90% improvement was found to be within reach for an optimized system. Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.

  18. What Do Patients Want to Know? Questions and Concerns Regarding Mammography Expressed Through Social Media.

    PubMed

    Charlie, Abbas M; Gao, Yiming; Heller, Samantha L

    2017-12-05

    The purpose of this project is to identify questions and concerns patients have regarding breast cancer screening mammography to establish priorities in patient education and health care communication. A content analysis of posted questions (June 2010 to February 2017) containing the keywords mammogram and mammography was conducted on the social media question and answer website Quora (Quora Inc, Mountainview, California). Question topic, responses, and number of views were recorded. Comparisons were made by respondent type (medical professional or nonmedical professional) for screening recommendations and accompanying evidence. Descriptive statistics were employed to summarize the results. Overall, 197,620 views of mammography-related questions were identified, focused on 51 questions and 172 responses (51 of 172 [29.7%] by medical professionals [n = 25]; 121 of 172 [70.3%] by nonmedical professionals [n = 121]). Mammographic efficacy (16 of 51 [31.4%]) and screening guidelines (10 of 51 [19.6%]) were the most frequently queried topics. Overall, the majority of respondents were supportive of screening mammography. Most medical professionals recommended screening mammography starting at age 40, even after revisions in guidelines. Among nonmedical professionals, 4 of 22 (18.2%) were against screening mammography with less consensus regarding appropriate age of initial screen. Health society websites and journal articles were the most commonly referenced sources among medical and nonmedical professionals, respectively. A considerable interest in screening mammography guidelines and mammographic efficacy exists among users who seek health information on a social media question and answer website. Awareness of such platforms allows a unique opportunity for targeted health education and dissemination of accurate information, which may be able to reach a potentially untapped or hard-to-reach patient population. Copyright © 2017 American College of Radiology

  19. Performance in physical examination on the USMLE Step 2 Clinical Skills examination.

    PubMed

    Peitzman, Steven J; Cuddy, Monica M

    2015-02-01

    To provide descriptive information about history-taking (HX) and physical examination (PE) performance for U.S. medical students as documented by standardized patients (SPs) during the Step 2 Clinical Skills (CS) component of the United States Medical Licensing Examination. The authors examined two hypotheses: (1) Students perform worse in PE compared with HX, and (2) for PE, students perform worse in the musculoskeletal system and neurology compared with other clinical domains. The sample included 121,767 student-SP encounters based on 29,442 examinees from U.S. medical schools who took Step 2 CS for the first time in 2011. The encounters comprised 107 clinical presentations, each categorized into one of five clinical domains: cardiovascular, gastrointestinal, musculoskeletal, neurological, and respiratory. The authors compared mean percent-correct scores for HX and PE via a one-tailed paired-samples t test and examined mean score differences by clinical domain using analysis of variance techniques. Average PE scores (59.6%) were significantly lower than average HX scores (78.1%). The range of scores for PE (51.4%-72.7%) was larger than for HX (74.4%-81.0%), and the standard deviation for PE scores (28.3) was twice as large as the HX standard deviation (14.7). PE performance was significantly weaker for musculoskeletal and neurological encounters compared with other encounters. U.S. medical students perform worse on PE than HX; PE performance was weakest in musculoskeletal and neurology clinical domains. Findings may reflect imbalances in U.S. medical education, but more research is needed to fully understand the relationships among PE instruction, assessment, and proficiency.

  20. Construct Validity of an Objective Structured Clinical Examination (OSCE) in Psychiatry: Associations with the Clinical Skills Examination and Other Indicators

    ERIC Educational Resources Information Center

    Park, Robin S.; Chibnall, John T.; Blaskiewicz, Robert J.; Furman, Gail E.; Powell, Jill K.; Mohr, Clinton J.

    2004-01-01

    Objective: The construct validity of checklist and global process scores for an objective structured clinical examination (OSCE) in psychiatry was assessed. Multiple regression analysis was used to predict psychiatry OSCE scores from the clinical skills examination, an obstetrics/gynecology (OB/GYN) OSCE, and the National Board of Medical…

  1. Comparison of radiologist performance with photon-counting full-field digital mammography to conventional full-field digital mammography.

    PubMed

    Cole, Elodia B; Toledano, Alicia Y; Lundqvist, Mats; Pisano, Etta D

    2012-08-01

    The purpose of this study was to assess the performance of a MicroDose photon-counting full-field digital mammography (PCM) system in comparison to full-field digital mammography (FFDM) for area under the receiver-operating characteristic (ROC) curve (AUC), sensitivity, specificity, and feature analysis of standard-view mammography for women presenting for screening mammography, diagnostic mammography, or breast biopsy. A total of 133 women were enrolled in this study at two European medical centers, with 67 women who had a pre-existing 10-36 months FFDM enrolled prospectively into the study and 66 women who underwent breast biopsy and had screening PCM and diagnostic FFDM, including standard craniocaudal and mediolateral oblique views of the breast with the lesion, enrolled retrospectively. The case mix consisted of 49 cancers, 17 biopsy-benign cases, and 67 normal cases. Sixteen radiologists participated in the reader study and interpreted all 133 cases in both conditions, separated by washout period of ≥4 weeks. ROC curve and free-response ROC curve analyses were performed for noninferiority of PCM compared to FFDM using a noninferiority margin Δ value of 0.10. Feature analysis of the 66 cases with lesions was conducted with all 16 readers at the conclusion of the blinded reads. Mean glandular dose was recorded for all cases. The AUC for PCM was 0.947 (95% confidence interval [CI], 0.920-0.974) and for FFDM was 0.931 (95% CI, 0.898-0.964). Sensitivity per case for PCM was 0.936 (95% CI, 0.897-0.976) and for FFDM was 0.908 (95% CI, 0.856-0.960). Specificity per case for PCM was 0.764 (95% CI, 0.688-0.841) and for FFDM was 0.749 (95% CI, 0.668-0.830). Free-response ROC curve figures of merit were 0.920 (95% CI, 0.881-0.959) and 0.903 (95% CI, 0.858-0.948) for PCM and FFDM, respectively. Sensitivity per lesion was 0.903 (95% CI, 0.846-0.960) and 0.883 (95% CI, 0.823-0.944) for PCM and FFDM, respectively. The average false-positive marks per image of noncancer

  2. Analysis of utilization patterns and associated costs of the breast imaging and diagnostic procedures after screening mammography.

    PubMed

    Vlahiotis, Anna; Griffin, Brian; Stavros, A Thomas; Margolis, Jay

    2018-01-01

    Little data exist on real-world patterns and associated costs of downstream breast diagnostic procedures following an abnormal screening mammography or clinical exam. To analyze the utilization patterns in real-world clinical settings for breast imaging and diagnostic procedures, including the frequency and volume of patients and procedures, procedure sequencing, and associated health care expenditures. Using medical claims from 2011 to 2015 MarketScan Commercial and Medicare Databases, adult females with breast imaging/diagnostic procedures (diagnostic mammography, ultrasound, molecular breast imaging, tomosynthesis, magnetic resonance imaging, or biopsy) other than screening mammography were selected. Continuous health plan coverage without breast diagnostic procedures was required for ≥13 months before the first found breast diagnostic procedure (index event), with a 13-month post-index follow-up period. Key outcomes included diagnostic procedure volumes, sequences, and payments. Results reported descriptively were projected to provide US national patient and procedure volumes. The final sample of 875,526 patients was nationally projected to 12,394,432 patients annually receiving 8,732,909 diagnostic mammograms (53.3% of patients), 6,987,399 breast ultrasounds (42.4% of patients), and 1,585,856 biopsies (10.3% of patients). Following initial diagnostic procedures, 49.4% had second procedures, 20.1% followed with third procedures, and 10.0% had a fourth procedure. Mean (SD) costs for diagnostic mammograms of US$349 ($493), ultrasounds US$132 ($134), and biopsies US$1,938 ($2,343) contributed US$3.05 billion, US$0.92 billion, and US$3.07 billion, respectively, to annual diagnostic breast expenditures estimated at US$7.91 billion. The volume and expense of additional breast diagnostic testing, estimated at US$7.91 billion annually, underscores the need for technological improvements in the breast diagnostic landscape.

  3. Face-to-face Information and Emotional Support from Trained Nurses Reduce Pain During Screening Mammography: Results from a Randomized Controlled Trial.

    PubMed

    Fernández-Feito, Ana; Lana, Alberto; Cabello-Gutiérrez, Lourdes; Franco-Correia, Sara; Baldonedo-Cernuda, Ricardo; Mosteiro-Díaz, Pilar

    2015-12-01

    Pain and discomfort during breast examination can affect a woman's adherence to breast cancer-screening programs. The aim of this study was to determine whether a nursing intervention protocol that provides verbal information and support to women could reduce pain during mammography. A randomized controlled trial of 436 Spanish women aged 50-69 who attended a breast-screening program was performed. The experimental group received a customized nursing intervention that provided face-to-face information and emotional support during the examination. Pain and anxiety were measured using a visual analogue scale and the State-Trait Anxiety Inventory, respectively. Data regarding several potential confounders were also collected. The adjusted means of pain level in the study group were obtained from multiple linear regressions, and the adjusted odds ratios (OR) and 95% confidence intervals (CI) were obtained via logistic regression. After the intervention, the level of pain was significantly lower (p = .03) in the experimental group (0.98 ± 2.28) compared with the group treated with normal care (1.48 ± 2.29). Consequently, the probability of feeling pain during mammography was lower among women in the experimental group (OR = 0.44; 95% CI: 0.24-0.81). The intervention was more effective among women with the highest anxiety levels (OR = 0.33; 95% CI: 0.11-0.98), who did not expect pain (OR = 0.28; 95% CI: 0.08-0.97), and who did not fear the outcome of the mammography (OR = 0.18; 95% CI: 0.04-0.85). Providing verbal information, as well as supporting the women during the test, is a simple and achievable intervention for nurses and can help to reduce pain during screening mammography. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  4. Finding the minimal intervention needed for sustained mammography adherence.

    PubMed

    Gierisch, Jennifer M; DeFrank, Jessica T; Bowling, J Michael; Rimer, Barbara K; Matuszewski, Jeanine M; Farrell, David; Skinner, Celette Sugg

    2010-10-01

    Regular adherence to mammography screening saves lives, yet few women receive regular mammograms. RCT. Participants were recruited through a state employee health plan. All were women aged 40-75 years and had recent mammograms prior to enrollment (n=3547). Data were collected from 2004 to 2009. Trial tested efficacy of a two-step adaptively-designed intervention to increase mammography adherence over 4 years. The first intervention step consisted of three reminder types: enhanced usual care reminders (EUCR); enhanced letter reminders (ELR); both delivered by mail, and automated telephone reminders (ATR). After delivery of reminders, women who became off-schedule in any of the 4 years received a second step of supplemental interventions. Three supplemental intervention arms contained priming letters and telephone counseling: barriers only (BarriCall); barriers plus positive consequences of getting mammograms (BarriConCall+); and barriers plus negative consequences of not getting mammograms (BarriConCall-). Average cumulative number of days non-adherent to mammography over 4 years based on annual screening guidelines (analyses conducted in 2009). All reminders performed equally well in reducing number of days of non-adherence. Women randomized to receive supplemental interventions had significantly fewer days of non-adherence compared to women who received EUCR (p=0.0003). BarrConCall+ and BarrConCall- conditions did not significantly differ in days non-adherent compared to women in the barriers-only condition (BarriCon). The minimal intervention needed for sustained mammography use is a combination of a reminder followed by a priming letter and barrier-specific telephone counseling for women who become off-schedule. Additional costs associated with supplemental interventions should be considered by organizations deciding which interventions to use. NCT01148875. Copyright © 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  5. [Malignant and benign diseases of the breast in 41 male patients: mammography, sonography and pathohistological correlations].

    PubMed

    Partik, B; Mallek, R; Rudas, M; Pokieser, P; Wunderbaldinger, P; Helbich, T H

    2001-11-01

    The goal of our study was to evaluate findings in mammography and sonography in male patients with pathohistologically proven diseases of the breast. Mammographies and sonographies, which were obtained in 41 male patients in a 6-year period, were retrospectively evaluated in accordance with the BI-RADS(R) classification. Histologically 13 carcinomas, 21 gynecomastias, 3 pseudogynecomastias, 2 epithelial inclusion cysts and 2 other benign lesions were diagnosed. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of mammography in differentiation of benign versus malignant disease were 92 %, 89 %, 80 %, 96 % and 90 %, respectively. Additional sonography did not change these results. However, sonography increased diagnostic confidence in 18.2 % (2/11) of suspicious lesions. In our study the invasive ductal carcinoma of male patients was a predominantly lobulated, ill-defined lesion in mammography and sonography. The differentiation of carcinoma to pseudogynecomastia and diffuse or dendritic gynecomastia was securely feasible. However, we could not reliably distinguish between carcinoma and some benign mass lesions. In cases of mammographically diagnosed masses or unclear mammography, additional sonography should be performed to increase the diagnostic confidence.

  6. Selective photon counter for digital x-ray mammography tomosynthesis

    NASA Astrophysics Data System (ADS)

    Goldan, Amir H.; Karim, Karim S.; Rowlands, J. A.

    2006-03-01

    Photon counting is an emerging detection technique that is promising for mammography tomosynthesis imagers. In photon counting systems, the value of each image pixel is equal to the number of photons that interact with the detector. In this research, we introduce the design and implementation of a low noise, novel selective photon counting pixel for digital mammography tomosynthesis in crystalline silicon CMOS (complementary metal oxide semiconductor) 0.18 micron technology. The design comprises of a low noise charge amplifier (CA), two low offset voltage comparators, a decision-making unit (DMU), a mode selector, and a pseudo-random counter. Theoretical calculations and simulation results of linearity, gain, and noise of the photon counting pixel are presented.

  7. Estimation of the Cost-Effectiveness of Breast Cancer Screening Using Mammography in Mexico Through a Simulation.

    PubMed

    Ulloa-Pérez, Ernesto; Mohar-Betancourt, Alejandro; Reynoso-Noverón, Nancy

    2016-01-01

    Currently, breast cancer is the most prevalent tumor among Mexican women. Screening methods such as mammography could potentially reduce the health and economic burden of breast cancer; however, its risk-benefit balance is still unclear. To estimate the cost-effectiveness of different breast cancer screening programs using mammography in Mexico and to contribute to the decision-making process on this preventive measure. A simulation study was performed using population data and incidence rates. Several screening programs were assessed using the cost-effectiveness methodology recommended by the World Health Organization. The feasible recommended screening program has an examination schedule periodicity of every three years, with a population coverage of 0, 15, 18, 20, 25, 20, 18, and 0% for the age groups of 25-40, 40-45, 45-50, 50-55, 55-60, 60-65, 65-70, and 70-75 years, respectively. Given the present coverage in Mexico, it is necessary to optimize our resource allocation to improve the country's breast cancer prevention policy.

  8. Personalizing mammography by breast density and other risk factors for breast cancer: analysis of health benefits and cost-effectiveness.

    PubMed

    Schousboe, John T; Kerlikowske, Karla; Loh, Andrew; Cummings, Steven R

    2011-07-05

    Current guidelines recommend mammography every 1 or 2 years starting at age 40 or 50 years, regardless of individual risk for breast cancer. To estimate the cost-effectiveness of mammography by age, breast density, history of breast biopsy, family history of breast cancer, and screening interval. Markov microsimulation model. Surveillance, Epidemiology, and End Results program, Breast Cancer Surveillance Consortium, and the medical literature. U.S. women aged 40 to 49, 50 to 59, 60 to 69, and 70 to 79 years with initial mammography at age 40 years and breast density of Breast Imaging Reporting and Data System (BI-RADS) categories 1 to 4. Lifetime. National health payer. Mammography annually, biennially, or every 3 to 4 years or no mammography. Costs per quality-adjusted life-year (QALY) gained and number of women screened over 10 years to prevent 1 death from breast cancer. Biennial mammography cost less than $100,000 per QALY gained for women aged 40 to 79 years with BI-RADS category 3 or 4 breast density or aged 50 to 69 years with category 2 density; women aged 60 to 79 years with category 1 density and either a family history of breast cancer or a previous breast biopsy; and all women aged 40 to 79 years with both a family history of breast cancer and a previous breast biopsy, regardless of breast density. Biennial mammography cost less than $50,000 per QALY gained for women aged 40 to 49 years with category 3 or 4 breast density and either a previous breast biopsy or a family history of breast cancer. Annual mammography was not cost-effective for any group, regardless of age or breast density. Mammography is expensive if the disutility of false-positive mammography results and the costs of detecting nonprogressive and nonlethal invasive cancer are considered. Results are not applicable to carriers of BRCA1 or BRCA2 mutations. Mammography screening should be personalized on the basis of a woman's age, breast density, history of breast biopsy, family history of

  9. Disparity between Clinical and Ultrasound Examinations in Neonatal Hip Screening.

    PubMed

    Kyung, Bong Soo; Lee, Soon Hyuck; Jeong, Woong Kyo; Park, Si Young

    2016-06-01

    For early detection of developmental dysplasia of the hip (DDH), neonatal hip screening using clinical examination and/or ultrasound has been recommended. Although there have been many studies on the reliability of both screening techniques, there is still controversy in the screening strategies; clinical vs. selective or universal ultrasound screening. To determine the screening strategy, we assessed the agreement among the methods; clinical examination by an experienced pediatric orthopedic surgeon, sonographic morphology, and sonographic stability. From January 2004 to June 2009, a single experienced pediatric orthopedic surgeon performed clinical hip screenings for 2,686 infants in the neonatal unit and 43 infants who were referred due to impressions of hip dysplasia before 3 months of age. Among them, 156 clinically unstable or high-risk babies selectively received bilateral hip ultrasound examinations performed by the same surgeon using the modified Graf method. The results were analyzed statistically to detect any correlations between the clinical and sonographic findings. Although a single experienced orthopedic surgeon conducted all examinations, we detected only a limited relationship between the results of clinical and ultrasound examinations. Ninety-three percent of the clinically subluxatable hips were normal or immature based on static ultrasound examination, and 74% of dislocating hips and 67% of limited abduction hips presented with the morphology below Graf IIa. A total of 80% of clinically subluxatable, 42% of dislocating and 67% of limited abduction hips appeared stable or exhibited minor instability on dynamic ultrasound examination. About 7% of clinically normal hips were abnormal upon ultrasound examination; 5% showed major instability and 3% showed dysplasia above Graf IIc. Clinical stability had small coefficients between ultrasound examinations; 0.39 for sonographic stability and 0.37 for sonographic morphology. Between sonographic

  10. The Impact of Acquisition Dose on Quantitative Breast Density Estimation with Digital Mammography: Results from ACRIN PA 4006.

    PubMed

    Chen, Lin; Ray, Shonket; Keller, Brad M; Pertuz, Said; McDonald, Elizabeth S; Conant, Emily F; Kontos, Despina

    2016-09-01

    Purpose To investigate the impact of radiation dose on breast density estimation in digital mammography. Materials and Methods With institutional review board approval and Health Insurance Portability and Accountability Act compliance under waiver of consent, a cohort of women from the American College of Radiology Imaging Network Pennsylvania 4006 trial was retrospectively analyzed. All patients underwent breast screening with a combination of dose protocols, including standard full-field digital mammography, low-dose digital mammography, and digital breast tomosynthesis. A total of 5832 images from 486 women were analyzed with previously validated, fully automated software for quantitative estimation of density. Clinical Breast Imaging Reporting and Data System (BI-RADS) density assessment results were also available from the trial reports. The influence of image acquisition radiation dose on quantitative breast density estimation was investigated with analysis of variance and linear regression. Pairwise comparisons of density estimations at different dose levels were performed with Student t test. Agreement of estimation was evaluated with quartile-weighted Cohen kappa values and Bland-Altman limits of agreement. Results Radiation dose of image acquisition did not significantly affect quantitative density measurements (analysis of variance, P = .37 to P = .75), with percent density demonstrating a high overall correlation between protocols (r = 0.88-0.95; weighted κ = 0.83-0.90). However, differences in breast percent density (1.04% and 3.84%, P < .05) were observed within high BI-RADS density categories, although they were significantly correlated across the different acquisition dose levels (r = 0.76-0.92, P < .05). Conclusion Precision and reproducibility of automated breast density measurements with digital mammography are not substantially affected by variations in radiation dose; thus, the use of low-dose techniques for the purpose of density estimation

  11. The Impact of Acquisition Dose on Quantitative Breast Density Estimation with Digital Mammography: Results from ACRIN PA 4006

    PubMed Central

    Chen, Lin; Ray, Shonket; Keller, Brad M.; Pertuz, Said; McDonald, Elizabeth S.; Conant, Emily F.

    2016-01-01

    Purpose To investigate the impact of radiation dose on breast density estimation in digital mammography. Materials and Methods With institutional review board approval and Health Insurance Portability and Accountability Act compliance under waiver of consent, a cohort of women from the American College of Radiology Imaging Network Pennsylvania 4006 trial was retrospectively analyzed. All patients underwent breast screening with a combination of dose protocols, including standard full-field digital mammography, low-dose digital mammography, and digital breast tomosynthesis. A total of 5832 images from 486 women were analyzed with previously validated, fully automated software for quantitative estimation of density. Clinical Breast Imaging Reporting and Data System (BI-RADS) density assessment results were also available from the trial reports. The influence of image acquisition radiation dose on quantitative breast density estimation was investigated with analysis of variance and linear regression. Pairwise comparisons of density estimations at different dose levels were performed with Student t test. Agreement of estimation was evaluated with quartile-weighted Cohen kappa values and Bland-Altman limits of agreement. Results Radiation dose of image acquisition did not significantly affect quantitative density measurements (analysis of variance, P = .37 to P = .75), with percent density demonstrating a high overall correlation between protocols (r = 0.88–0.95; weighted κ = 0.83–0.90). However, differences in breast percent density (1.04% and 3.84%, P < .05) were observed within high BI-RADS density categories, although they were significantly correlated across the different acquisition dose levels (r = 0.76–0.92, P < .05). Conclusion Precision and reproducibility of automated breast density measurements with digital mammography are not substantially affected by variations in radiation dose; thus, the use of low-dose techniques for the purpose of density

  12. Screening Mammography: Patient Perceptions and Preferences Regarding Communication of Estimated Breast Cancer Risk.

    PubMed

    Amornsiripanitch, Nita; Mangano, Mark; Niell, Bethany L

    2017-05-01

    Many models exist to estimate a woman's risk of development of breast cancer. At screening mammography, many imaging centers collect data required for these models to identify women who may benefit from supplemental screening and referral for cancer risk assessment. The purpose of this study was to discern perceptions and preferences of screening mammography patients regarding communication of estimated breast cancer risk. An anonymous survey was distributed to screening and surveillance mammography patients between April and June 2015. Survey questions were designed to assess patient preferences regarding the receipt and complexity of risk estimate communication, including hypothetical scenarios with and without > 20% estimated risk of breast cancer. The McNemar test and the Wilcoxon signed rank test were used with p ≤ 0.05 considered statistically significant. The survey was distributed to 1061 screening and surveillance mammography patients, and 503 patients responded (response rate, 47%). Although 86% (431/503) of patients expressed interest in learning their estimated risk, only 8% (38/503) had undergone formal risk assessment. The preferred method (241 respondents [26%]) of communication of risk < 20% was a mailed letter accompanying annual mammogram results. For risk > 20%, patients preferred oral communication and were 10-fold as likely to choose only oral communication (p < 0.000001). For risk < 20% and > 20%, patients preferred to learn their estimated risk in great detail (69% and 85%), although women were significantly more likely to choose greater detail for risk > 20% (p < 0.00001). Screening mammography patients expressed interest in learning their estimated risk of breast cancer regardless of their level of hypothetical risk.

  13. Contrast-enhanced spectral mammography based on a photon-counting detector: quantitative accuracy and radiation dose

    NASA Astrophysics Data System (ADS)

    Lee, Seungwan; Kang, Sooncheol; Eom, Jisoo

    2017-03-01

    Contrast-enhanced mammography has been used to demonstrate functional information about a breast tumor by injecting contrast agents. However, a conventional technique with a single exposure degrades the efficiency of tumor detection due to structure overlapping. Dual-energy techniques with energy-integrating detectors (EIDs) also cause an increase of radiation dose and an inaccuracy of material decomposition due to the limitations of EIDs. On the other hands, spectral mammography with photon-counting detectors (PCDs) is able to resolve the issues induced by the conventional technique and EIDs using their energy-discrimination capabilities. In this study, the contrast-enhanced spectral mammography based on a PCD was implemented by using a polychromatic dual-energy model, and the proposed technique was compared with the dual-energy technique with an EID in terms of quantitative accuracy and radiation dose. The results showed that the proposed technique improved the quantitative accuracy as well as reduced radiation dose comparing to the dual-energy technique with an EID. The quantitative accuracy of the contrast-enhanced spectral mammography based on a PCD was slightly improved as a function of radiation dose. Therefore, the contrast-enhanced spectral mammography based on a PCD is able to provide useful information for detecting breast tumors and improving diagnostic accuracy.

  14. MO-AB-207-04: ACR Update in Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berns, E.

    2015-06-15

    A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date asmore » the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.« less

  15. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    PubMed

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  16. Contribution of mammography to MRI screening in BRCA mutation carriers by BRCA status and age: individual patient data meta-analysis

    PubMed Central

    Phi, Xuan-Anh; Saadatmand, Sepideh; De Bock, Geertruida H; Warner, Ellen; Sardanelli, Francesco; Leach, Martin O; Riedl, Christopher C; Trop, Isabelle; Hooning, Maartje J; Mandel, Rodica; Santoro, Filippo; Kwan-Lim, Gek; Helbich, Thomas H; Tilanus-Linthorst, Madeleine MA; van den Heuvel, Edwin R; Houssami, Nehmat

    2016-01-01

    Background: We investigated the additional contribution of mammography to screening accuracy in BRCA1/2 mutation carriers screened with MRI at different ages using individual patient data from six high-risk screening trials. Methods: Sensitivity and specificity of MRI, mammography and the combination of these tests were compared stratified for BRCA mutation and age using generalised linear mixed models with random effect for studies. Number of screens needed (NSN) for additional mammography-only detected cancer was estimated. Results: In BRCA1/2 mutation carriers of all ages (BRCA1=1219 and BRCA2=732), adding mammography to MRI did not significantly increase screening sensitivity (increased by 3.9% in BRCA1 and 12.6% in BRCA2 mutation carriers, P>0.05). However, in women with BRCA2 mutation younger than 40 years, one-third of breast cancers were detected by mammography only. Number of screens needed for mammography to detect one breast cancer not detected by MRI was much higher for BRCA1 compared with BRCA2 mutation carriers at initial and repeat screening. Conclusions: Additional screening sensitivity from mammography above that from MRI is limited in BRCA1 mutation carriers, whereas mammography contributes to screening sensitivity in BRCA2 mutation carriers, especially those ⩽40 years. The evidence from our work highlights that a differential screening schedule by BRCA status is worth considering. PMID:26908327

  17. Contribution of mammography to MRI screening in BRCA mutation carriers by BRCA status and age: individual patient data meta-analysis.

    PubMed

    Phi, Xuan-Anh; Saadatmand, Sepideh; De Bock, Geertruida H; Warner, Ellen; Sardanelli, Francesco; Leach, Martin O; Riedl, Christopher C; Trop, Isabelle; Hooning, Maartje J; Mandel, Rodica; Santoro, Filippo; Kwan-Lim, Gek; Helbich, Thomas H; Tilanus-Linthorst, Madeleine M A; van den Heuvel, Edwin R; Houssami, Nehmat

    2016-03-15

    We investigated the additional contribution of mammography to screening accuracy in BRCA1/2 mutation carriers screened with MRI at different ages using individual patient data from six high-risk screening trials. Sensitivity and specificity of MRI, mammography and the combination of these tests were compared stratified for BRCA mutation and age using generalised linear mixed models with random effect for studies. Number of screens needed (NSN) for additional mammography-only detected cancer was estimated. In BRCA1/2 mutation carriers of all ages (BRCA1 = 1,219 and BRCA2 = 732), adding mammography to MRI did not significantly increase screening sensitivity (increased by 3.9% in BRCA1 and 12.6% in BRCA2 mutation carriers, P > 0.05). However, in women with BRCA2 mutation younger than 40 years, one-third of breast cancers were detected by mammography only. Number of screens needed for mammography to detect one breast cancer not detected by MRI was much higher for BRCA1 compared with BRCA2 mutation carriers at initial and repeat screening. Additional screening sensitivity from mammography above that from MRI is limited in BRCA1 mutation carriers, whereas mammography contributes to screening sensitivity in BRCA2 mutation carriers, especially those ⩽ 40 years. The evidence from our work highlights that a differential screening schedule by BRCA status is worth considering.

  18. TU-CD-207-01: Characterization of Breast Tissue Composition Using Spectral Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, H; Cho, H; Kumar, N

    Purpose: To investigate the feasibility of characterizing the chemical composition of breast tissue, in terms of water and lipid, by using spectral mammography in simulation and postmortem studies. Methods: Analytical simulations were performed to obtain low- and high-energy signals of breast tissue based on previously reported water, lipid, and protein contents. Dual-energy decomposition was used to characterize the simulated breast tissue into water and lipid basis materials and the measured water density was compared to the known value. In experimental studies, postmortem breasts were imaged with a spectral mammography system based on a scanning multi-slit Si strip photon-counting detector. Low-more » and high-energy images were acquired simultaneously from a single exposure by sorting the recorded photons into the corresponding energy bins. Dual-energy material decomposition of the low- and high-energy images yielded individual pixel measurements of breast tissue composition in terms of water and lipid thicknesses. After imaging, each postmortem breast was chemically decomposed into water, lipid and protein. The water density calculated from chemical analysis was used as the reference gold standard. Correlation of the water density measurements between spectral mammography and chemical analysis was analyzed using linear regression. Results: Both simulation and postmortem studies showed good linear correlation between the decomposed water thickness using spectral mammography and chemical analysis. The slope of the linear fitting function in the simulation and postmortem studies were 1.15 and 1.21, respectively. Conclusion: The results indicate that breast tissue composition, in terms of water and lipid, can be accurately measured using spectral mammography. Quantitative breast tissue composition can potentially be used to stratify patients according to their breast cancer risk.« less

  19. Cost-effectiveness of breast cancer screening using mammography in Vietnamese women

    PubMed Central

    2018-01-01

    Background The incidence rate of breast cancer is increasing and has become the most common cancer in Vietnamese women while the survival rate is lower than that of developed countries. Early detection to improve breast cancer survival as well as reducing risk factors remains the cornerstone of breast cancer control according to the World Health Organization (WHO). This study aims to evaluate the costs and outcomes of introducing a mammography screening program for Vietnamese women aged 45–64 years, compared to the current situation of no screening. Methods Decision analytical modeling using Markov chain analysis was used to estimate costs and health outcomes over a lifetime horizon. Model inputs were derived from published literature and the results were reported as incremental cost-effectiveness ratios (ICERs) and/or incremental net monetary benefits (INMBs). One-way sensitivity analyses and probabilistic sensitivity analyses were performed to assess parameter uncertainty. Results The ICER per life year gained of the first round of mammography screening was US$3647.06 and US$4405.44 for women aged 50–54 years and 55–59 years, respectively. In probabilistic sensitivity analyses, mammography screening in the 50–54 age group and the 55–59 age group were cost-effective in 100% of cases at a threshold of three times the Vietnamese Gross Domestic Product (GDP) i.e., US$6332.70. However, less than 50% of the cases in the 60–64 age group and 0% of the cases in the 45–49 age group were cost effective at the WHO threshold. The ICERs were sensitive to the discount rate, mammography sensitivity, and transition probability from remission to distant recurrence in stage II for all age groups. Conclusion From the healthcare payer viewpoint, offering the first round of mammography screening to Vietnamese women aged 50–59 years should be considered, with the given threshold of three times the Vietnamese GDP per capita. PMID:29579131

  20. Screening for breast cancer: U.S. Preventive Services Task Force recommendation statement.

    PubMed

    2009-11-17

    Update of the 2002 U.S. Preventive Services Task Force (USPSTF) recommendation statement on screening for breast cancer in the general population. The USPSTF examined the evidence on the efficacy of 5 screening modalities in reducing mortality from breast cancer: film mammography, clinical breast examination, breast self-examination, digital mammography, and magnetic resonance imaging in order to update the 2002 recommendation. To accomplish this update, the USPSTF commissioned 2 studies: 1) a targeted systematic evidence review of 6 selected questions relating to benefits and harms of screening, and 2) a decision analysis that used population modeling techniques to compare the expected health outcomes and resource requirements of starting and ending mammography screening at different ages and using annual versus biennial screening intervals. The USPSTF recommends against routine screening mammography in women aged 40 to 49 years. The decision to start regular, biennial screening mammography before the age of 50 years should be an individual one and take into account patient context, including the patient's values regarding specific benefits and harms. (Grade C recommendation) The USPSTF recommends biennial screening mammography for women between the ages of 50 and 74 years. (Grade B recommendation) The USPSTF concludes that the current evidence is insufficient to assess the additional benefits and harms of screening mammography in women 75 years or older. (I statement) The USPSTF concludes that the current evidence is insufficient to assess the additional benefits and harms of clinical breast examination beyond screening mammography in women 40 years or older. (I statement) The USPSTF recommends against clinicians teaching women how to perform breast self-examination. (Grade D recommendation) The USPSTF concludes that the current evidence is insufficient to assess additional benefits and harms of either digital mammography or magnetic resonance imaging instead of

  1. Breast cancer stage at diagnosis and geographic access to mammography screening (New Hampshire, 1998-2004).

    PubMed

    Celaya, Maria O; Berke, Ethan M; Onega, Tracy L; Gui, Jiang; Riddle, Bruce L; Cherala, Sai S; Rees, Judy R

    2010-01-01

    Early detection of breast cancer by screening mammography aims to increase treatment options and decrease mortality. Recent studies have shown inconsistent results in their investigations of the possible association between travel distance to mammography and stage of breast cancer at diagnosis. The purpose of the study was to investigate whether geographic access to mammography screening is associated with the stage at breast cancer diagnosis. Using the state's population-based cancer registry, all female residents of New Hampshire aged > or =40 years who were diagnosed with breast cancer during 1998-2004 were identified. The factors associated with early stage (stages 0 to 2) or later stage (stages 3 and 4) diagnosis of breast cancer were compared, with emphasis on the distance a woman lived from the closest mammography screening facility, and residence in rural and urban locations. A total of 5966 New Hampshire women were diagnosed with breast cancer during 1998-2004. Their mean driving distance to the nearest mammography facility was 8.85 km (range 0-44.26; 5.5 miles, range 0-27.5), with a mean estimated travel time of 8.9 min (range 0.0-42.2). The distribution of travel distance (and travel time) was substantially skewed to the right: 56% of patients lived within 8 km (5 miles) of a mammography facility, and 65% had a travel time of less than 10 min. There was no significant association between later stage of breast cancer and travel time to the nearest mammography facility. Using 3 categories of rural/urban residence based on Rural Urban Commuting Area classification, no significant association between rural residence and stage of diagnosis was found. New Hampshire women were more likely to be diagnosed with breast cancer at later stages if they lacked private health insurance (p<0.001), were not married (p<0.001), were older (p<0.001), and there was a borderline association with diagnosis during non-winter months (p=0.074). Most women living in New Hampshire

  2. Breast Cancer and Mammography Screening: Knowledge, Beliefs and Predictors for Asian Immigrant Women Attending a Specialized Clinic in British Columbia, Canada.

    PubMed

    Hippman, Catriona; Moshrefzadeh, Arezu; Lohn, Zoe; Hodgson, Zoë G; Dewar, Kathryn; Lam, Melanie; Albert, Arianne Y K; Kwong, Juliet

    2016-12-01

    Screening mammography (MMG) reduces breast cancer mortality; however, Asian immigrant women underutilize MMG. The Asian Women's Health Clinic (AWHC) was established to promote women's cancer screening amongst this population. This study evaluated the rate, and predictors, of MMG amongst women attending the AWHC. Women (N = 98) attending the AWHC completed a questionnaire. Descriptive statistics and multivariable logistic regression evaluated rate and predictors of MMG. Most participants (87 %, n = 85) reported having had a mammogram. Significant MMG predictors were: lower perceived MMG barriers [lifetime: OR (CI) 1.19 (1.01-1.49); past 2 years: OR (CI) 1.11 (1.01-1.25)], and knowing someone with breast cancer [past year: OR (CI) 3.42 (1.25-9.85); past 2 years: OR (CI) 4.91 (1.32-2.13)]. Even amongst women using preventive medicine, 13 % report never having had a mammogram. More research is needed into innovative interventions, e.g. the AWHC, and breast cancer-related outcomes amongst Asian immigrant women.

  3. A multi-centre randomised trial comparing ultrasound vs mammography for screening breast cancer in high-risk Chinese women.

    PubMed

    Shen, S; Zhou, Y; Xu, Y; Zhang, B; Duan, X; Huang, R; Li, B; Shi, Y; Shao, Z; Liao, H; Jiang, J; Shen, N; Zhang, J; Yu, C; Jiang, H; Li, S; Han, S; Ma, J; Sun, Q

    2015-03-17

    Chinese women tend to have small and dense breasts and ultrasound is a common method for breast cancer screening in China. However, its efficacy and cost comparing with mammography has not been evaluated in randomised trials. At 14 breast centres across China during 2008-2010, 13 339 high-risk women aged 30-65 years were randomised to be screened by mammography alone, ultrasound alone, or by both methods at enrollment and 1-year follow-up. A total of 12 519 and 8692 women underwent the initial and second screenings, respectively. Among the 30 cancers (of which 15 were stage 0/I) detected, 5 (0.72/1000) were in the mammography group, 11 (1.51/1000) in the ultrasound group, and 14 (2.02/1000) in the combined group (P=0.12). In the combined group, ultrasound detected all the 14 cancers, whereas mammography detected 8, making ultrasound more sensitive (100 vs 57.1%, P=0.04) with a better diagnostic accuracy (0.999 vs 0.766, P=0.01). There was no difference between mammography and ultrasound in specificity (100 vs 99.9%, P=0.51) and positive predictive value (72.7 vs 70.0%; P=0.87). To detect one cancer, the costs of ultrasound, mammography, and combined modality were $7876, $45 253, and $21 599, respectively. Ultrasound is superior to mammography for breast cancer screening in high-risk Chinese women.

  4. Discount rates and the education gradient in mammography in the UK.

    PubMed

    Bíró, Anikó

    2013-09-01

    I analyse intertemporal decisions on undertaking breast cancer screening by women aged 50-64  years in the UK and provide estimates of the rate of discounting potential future benefits of screening. I also analyse education differences in mammography decisions and examine the underlying mechanisms by which education influences breast cancer screening attendance. I estimate a structural model, which reveals that although there are differences in the disutility of breast cancer screening between education groups, there is no difference in the estimated discount factor. These results suggest that the observed education gradient is mainly due to differences in health behaviours and healthcare attitudes. Copyright © 2013 John Wiley & Sons, Ltd.

  5. [Effectiveness of a quality control program in mammography for the Brazilian National Health System].

    PubMed

    Corrêa, Rosangela da Silveira; Freitas-Junior, Ruffo; Peixoto, João Emílio; Rodrigues, Danielle Cristina Netto; Lemos, Maria Eugênia Fonseca; Dias, Cíntia Melazo; Ferreira, Rubemar de Souza; Rahal, Rosemar Macedo Souza

    2012-10-01

    To assess the effectiveness of a quality control program in mammography services of the Brazilian National Health System (SUS). A prospective study using temporal analysis of a health surveillance action was conducted. A total of 35 service providers that had mammography equipment in operation and regularly performed exams between 2007 and 2009 in the state of Goiás, Central-Western Brazil, participated in this study. Services were assessed during three site visits by performance testing of mammography equipment, film processors, and other materials, and image quality and entrance surface dose in a phantom were also assessed. Each service was scored according to the percentage of tests that conformed to standards. The mean percentage for compliance among the participating service providers were 64.1% (± 13.3%) in the first visit, 68.4% (± 15.9%) in the second, and 77.1% (± 13.3%) in the third (p < 0.001). The main improvements resulted from adjustments to the breast compression force, the automatic exposure control system, and the alignment of the compression paddle. The doses measured were within the conformity range in 80% of the services assessed. The implementation of this program in the mammography services was effective at improving the operational parameters of the mammography machines, although 40% of the services did not reach the acceptable level of 70%. This result indicates the need to continue this health surveillance action.

  6. Radiological and clinical features of adult non-puerperal mastitis

    PubMed Central

    Tan, H; Li, R; Liu, H; Gu, Y; Shen, X

    2013-01-01

    Objective: To describe the radiological and clinical features of adult non-puerperal mastitis and to determine the most accurate method of preventing unnecessary surgical procedures. Methods: Clinical and imaging findings were retrospectively reviewed in 51 females with non-puerperal mastitis, which was confirmed by biopsy/surgical pathology. All 51 patients had pre-operative MRI; 45 patients also had sonograms and 25 also had mammograms, pre-operatively. Results: Of the 51 cases with non-puerperal mastitis, 94.1% (48/51) were confirmed as having acute or chronic inflammation, and the other 3 had plasma cell mastitis; areola papillaris inflammation was found in 39.2% (20/51) of the cases. Overall, 6 of the 25 cases that were examined with mammography and 2 of the 45 cases that were examined with sonography appeared normal, but all 51 lesions were positively identified on MRI. Asymmetrical density (12/25) on mammograms and solitary or separated/contiguous, clustered, hypoechoic mass-like lesions (31/45) on ultrasound were the most common signs of non-puerperal mastitis. On enhanced MRI, 90.2% (46/51) of patients showed non-mass-like enhanced lesions. Multiple regional enhancements in the pattern of distribution (32/46) and separated or contiguous, clustered, rim-like enhancements in the pattern of internal enhancement (29/46) were the most common manifestations in non-mass-like enhanced lesions. Of the 51 patients, mastitis Type 1 and Type 2 in the time–signal intensity curve were detected in 47.1% and 51.0% of the patients, respectively. The breast imaging reporting and data system categories with the highest number of patients were Category 0 (9/25) on mammography, Category 4a on sonography (18/45) and Category 4a on MRI (29/51). Conclusion: The findings from mammography and ultrasound are non-specific; therefore, using MR can be helpful in the diagnosis, especially in the presence of non-mass-like enhancements that are multiple, regional, separated, or

  7. The impact of age on the art of mammography and how to adapt accordingly.

    PubMed

    Lake, B; Cielecki, L; Williams, S; Worrall, C; Metelko, M

    2017-11-01

    Breast cancer is increasingly a disease of the elderly, and combined with the NHS Breast Screening Extension means that more elderly patients are having mammography. Increasing age can make mammography more technically difficult. This is a technical note detailing the results of a local audit which may be of interest due to potential service implications. A retrospective audit of the first year of screening extension of The Shropshire Breast Screening Programme. Aims to collect data on patient demographics and describe the technical adaptations developed in Shropshire. Breast screening extension has increased by 2.5 times the number of women aged 70-74 screened, and doubled the overall numbers of women over 70 screened. Significantly more older patients are being screened to present technical challenges to a screening programme. Data was obtained from a month of screening showed that 29% of patients over 70 needed extra time for positioning. Reasons included 22% difficulty in obtaining adequate positioning and 15% needed a relative to aid with consent. In the Shropshire screening programme different technical adaptations have been developed and are key to ensuring adequate images. These include double appointments, two radiographers, thorough assessment, steeper angles, seated examinations, from-below imaging and pre-planning for subsequent screen. Significantly more older women are having breast screening due to the increasing incidence of breast cancer and the Breast Screening Programme extension. Increasing age can significantly increase time taken for adequate imaging and present technical challenges. Development of technical adaptations to art of mammography is key to achieve adequate images. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  8. Improved visualization of breast cancer features in multifocal carcinoma using phase-contrast and dark-field mammography: an ex vivo study.

    PubMed

    Grandl, Susanne; Scherer, Kai; Sztrókay-Gaul, Anikó; Birnbacher, Lorenz; Willer, Konstantin; Chabior, Michael; Herzen, Julia; Mayr, Doris; Auweter, Sigrid D; Pfeiffer, Franz; Bamberg, Fabian; Hellerhoff, Karin

    2015-12-01

    Conventional X-ray attenuation-based contrast is inherently low for the soft-tissue components of the female breast. To overcome this limitation, we investigate the diagnostic merits arising from dark-field mammography by means of certain tumour structures enclosed within freshly dissected mastectomy samples. We performed grating-based absorption, absolute phase and dark-field mammography of three freshly dissected mastectomy samples containing bi- and multifocal carcinoma using a compact, laboratory Talbot-Lau interferometer. Preoperative in vivo imaging (digital mammography, ultrasound, MRI), postoperative histopathological analysis and ex vivo digital mammograms of all samples were acquired for the diagnostic verification of our results. In the diagnosis of multifocal tumour growth, dark-field mammography seems superior to standard breast imaging modalities, providing a better resolution of small, calcified tumour nodules, demarcation of tumour boundaries with desmoplastic stromal response and spiculated soft-tissue strands extending from an invasive ductal breast cancer. On the basis of selected cases, we demonstrate that dark-field mammography is capable of outperforming conventional mammographic imaging of tumour features in both calcified and non-calcified tumours. Presuming dose optimization, our results encourage further studies on larger patient cohorts to identify those patients that will benefit the most from this promising additional imaging modality. • X-ray dark-field mammography provides significantly improved visualization of tumour features • X-ray dark-field mammography is capable of outperforming conventional mammographic imaging • X-ray dark-field mammography provides imaging sensitivity towards highly dispersed calcium grains.

  9. Screening Mammography for Free: Impact of Eliminating Cost Sharing on Cancer Screening Rates.

    PubMed

    Jena, Anupam B; Huang, Jie; Fireman, Bruce; Fung, Vicki; Gazelle, Scott; Landrum, Mary Beth; Chernew, Michael; Newhouse, Joseph P; Hsu, John

    2017-02-01

    To study the impact of eliminating cost sharing for screening mammography on mammography rates in a large Medicare Advantage (MA) health plan which in 2010 eliminated cost sharing in anticipation of the Affordable Care Act mandate. Large MA health maintenance organization offering individual-subscriber MA insurance and employer-supplemented group MA insurance. We investigated the impact on breast cancer screening of a policy that eliminated a $20 copayment for screening mammography in 2010 among 53,188 women continuously enrolled from 2007 to 2012 in an individual-subscriber MA plan, compared with 42,473 women with employer-supplemented group MA insurance in the same health maintenance organization who had full screening coverage during this period. We used differences-in-differences analysis to study the impact of cost-sharing elimination on mammography rates. Annual screening rates declined over time for both groups, with similar trends pre-2010 and a slower decline after 2010 among women whose copayments were eliminated. Among women aged 65-74 years in the individual-subscriber MA plan, 44.9 percent received screening in 2009 compared with 40.9 percent in 2012, while 49.5 percent of women in the employer-supplemented MA plan received screening in 2009 compared with 44.1 percent in 2012, that is, a difference-in-difference effect of 1.4 percentage points less decline in screening among women experiencing the cost-sharing elimination. Effects were concentrated among women without recent screening. There were no differences by neighborhood socioeconomic status or race/ethnicity. Eliminating cost sharing for screening mammography was associated with modesty lower decline in screening rates among women with previously low screening adherence. © Health Research and Educational Trust.

  10. High dynamic range CMOS-based mammography detector for FFDM and DBT

    NASA Astrophysics Data System (ADS)

    Peters, Inge M.; Smit, Chiel; Miller, James J.; Lomako, Andrey

    2016-03-01

    Digital Breast Tomosynthesis (DBT) requires excellent image quality in a dynamic mode at very low dose levels while Full Field Digital Mammography (FFDM) is a static imaging modality that requires high saturation dose levels. These opposing requirements can only be met by a dynamic detector with a high dynamic range. This paper will discuss a wafer-scale CMOS-based mammography detector with 49.5 μm pixels and a CsI scintillator. Excellent image quality is obtained for FFDM as well as DBT applications, comparing favorably with a-Se detectors that dominate the X-ray mammography market today. The typical dynamic range of a mammography detector is not high enough to accommodate both the low noise and the high saturation dose requirements for DBT and FFDM applications, respectively. An approach based on gain switching does not provide the signal-to-noise benefits in the low-dose DBT conditions. The solution to this is to add frame summing functionality to the detector. In one X-ray pulse several image frames will be acquired and summed. The requirements to implement this into a detector are low noise levels, high frame rates and low lag performance, all of which are unique characteristics of CMOS detectors. Results are presented to prove that excellent image quality is achieved, using a single detector for both DBT as well as FFDM dose conditions. This method of frame summing gave the opportunity to optimize the detector noise and saturation level for DBT applications, to achieve high DQE level at low dose, without compromising the FFDM performance.

  11. Mobile mammography: An evaluation of organizational, process, and information systems challenges.

    PubMed

    Browder, Casey; Eberth, Jan M; Schooley, Benjamin; Porter, Nancy R

    2015-03-01

    The purpose of this case study was to evaluate the information systems, personnel, and processes involved in mobile mammography settings, and offer recommendations to improve efficiency and satisfaction among patients and staff. Data includes on-site observations, interviews, and an electronic medical record review of a hospital who offers both mobile and fixed facility mammography services to their community. The optimal expectations for the process of mobile mammography from multiple perspectives were defined as (1) patient receives mammogram the day of their visit, (2) patient has efficient intake process with little wait time, (3) follow-up is completed and timely, (4) site contact and van staff are satisfied with van visit and choose to schedule future visits, and (5) the MMU is able to assess its performance and set goals for improvement. Challenges that prevent the realization of those expectations include a low patient pre-registration rate, difficulty obtaining required physician orders, frequent information system downtime/Internet connectivity issues, ill-defined organizational communication/roles, insufficient site host/patient education, and disparate organizational and information systems. Our recommendations include employing a dedicated mobile mammography team for end-to-end oversight, mitigating for system connectivity issues, allowing for patient self-referrals, integrating scheduling and registration processes, and a focused approach to educating site hosts and respective patients about expectations for the day of the visit. The MMU is an important community resource; we recommend simple process improvements and information flow improvements to further enable the MMU׳s goals. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Seamless lesion insertion in digital mammography: methodology and reader study

    NASA Astrophysics Data System (ADS)

    Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2016-03-01

    Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.

  13. Method for simulating dose reduction in digital mammography using the Anscombe transformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borges, Lucas R., E-mail: lucas.rodrigues.borges@usp.br; Oliveira, Helder C. R. de; Nunes, Polyana F.

    2016-06-15

    Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtainedmore » by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the

  14. Method for simulating dose reduction in digital mammography using the Anscombe transformation

    PubMed Central

    Borges, Lucas R.; de Oliveira, Helder C. R.; Nunes, Polyana F.; Bakic, Predrag R.; Maidment, Andrew D. A.; Vieira, Marcelo A. C.

    2016-01-01

    Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe

  15. Method for simulating dose reduction in digital mammography using the Anscombe transformation.

    PubMed

    Borges, Lucas R; Oliveira, Helder C R de; Nunes, Polyana F; Bakic, Predrag R; Maidment, Andrew D A; Vieira, Marcelo A C

    2016-06-01

    This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise

  16. Entertainment-Education Narrative Versus Nonnarrative Interventions to Educate and Motivate Latinas to Engage in Mammography Screening.

    PubMed

    Borrayo, Evelinn A; Rosales, Monica; Gonzalez, Patricia

    2017-06-01

    The evidence is limited comparing the effects of entertainment-education (E-E) narrative versus nonnarrative interventions to educate and motivate Latinas to engage in mammography screening. This study compared an E-E narrative intervention to two nonnarrative interventions' effects among Latinas on breast cancer knowledge and motivation, as measured by changes in self-efficacy, behavioral norms, and behavioral intentions to engage in mammography screening. A sample of 141 Spanish-speaking Latinas was randomly assigned to one of three arms: an E-E narrative video, a nonnarrative educational video, and printed educational materials. Using a repeated measures design, the influence of the E-E narrative on pretest to posttest measures was assessed and compared to the influence of the other two interventions. The E-E narrative and nonnarrative interventions significantly increased Latinas' breast cancer knowledge, mammography self-efficacy, and behavioral norms from pretest to posttest. However, the E-E narrative participants' pretest to posttest difference in mammography self-efficacy was significantly higher when compared to the difference of the other two interventions. The effect of the E-E narrative intervention on self-efficacy and behavioral norms was moderated by the participants' absorption in the story and identification with the story characters. E-E narrative and nonnarrative interventions significantly educated and motivated Latinas to engage in mammography screening. The effects on mammography self-efficacy, an important precursor to behavior change, can be more strongly influenced by E-E narratives. Although E-E narrative and nonnarrative interventions were effective, the need still exists to assess if they can ultimately influence lifesaving breast cancer screening behaviors.

  17. Predisposing and Enabling Factors Associated with Mammography Use among Hispanic and Non-Hispanic White Women Living in a Rural Area

    ERIC Educational Resources Information Center

    Tejeda, Silvia; Thompson, Beti; Coronado, Gloria D.; Martin, Diane P.; Heagerty, Patrick J.

    2009-01-01

    Context: Women who do not receive regular mammograms are more likely than others to have breast cancer diagnosed at an advanced stage. Purpose: To examine predisposing and enabling factors associated with mammography use among Hispanic and non-Hispanic White women. Methods: Baseline data were used from a larger study on cancer prevention in rural…

  18. Image enhancement in positron emission mammography

    NASA Astrophysics Data System (ADS)

    Slavine, Nikolai V.; Seiler, Stephen; McColl, Roderick W.; Lenkinski, Robert E.

    2017-02-01

    Purpose: To evaluate an efficient iterative deconvolution method (RSEMD) for improving the quantitative accuracy of previously reconstructed breast images by commercial positron emission mammography (PEM) scanner. Materials and Methods: The RSEMD method was tested on breast phantom data and clinical PEM imaging data. Data acquisition was performed on a commercial Naviscan Flex Solo II PEM camera. This method was applied to patient breast images previously reconstructed with Naviscan software (MLEM) to determine improvements in resolution, signal to noise ratio (SNR) and contrast to noise ratio (CNR.) Results: In all of the patients' breast studies the post-processed images proved to have higher resolution and lower noise as compared with images reconstructed by conventional methods. In general, the values of SNR reached a plateau at around 6 iterations with an improvement factor of about 2 for post-processed Flex Solo II PEM images. Improvements in image resolution after the application of RSEMD have also been demonstrated. Conclusions: A rapidly converging, iterative deconvolution algorithm with a novel resolution subsets-based approach RSEMD that operates on patient DICOM images has been used for quantitative improvement in breast imaging. The RSEMD method can be applied to clinical PEM images to improve image quality to diagnostically acceptable levels and will be crucial in order to facilitate diagnosis of tumor progression at the earliest stages. The RSEMD method can be considered as an extended Richardson-Lucy algorithm with multiple resolution levels (resolution subsets).

  19. TH-A-18A-01: Innovation in Clinical Breast Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, B; Yang, K; Yaffe, M

    Several novel modalities have been or are on the verge of being introduced into the breast imaging clinic. These include tomosynthesis imaging, dedicated breast CT, contrast-enhanced digital mammography, and automated breast ultrasound, all of which are covered in this course. Tomosynthesis and dedicated breast CT address the problem of tissue superimposition that limits mammography screening performance, by improved or full resolution of the 3D breast morphology. Contrast-enhanced digital mammography provides functional information that allows for visualization of tumor angiogenesis. 3D breast ultrasound has high sensitivity for tumor detection in dense breasts, but the imaging exam was traditionally performed by radiologists.more » In automated breast ultrasound, the scan is performed in an automated fashion, making for a more practical imaging tool, that is now used as an adjunct to digital mammography in breast cancer screening. This course will provide medical physicists with an in-depth understanding of the imaging physics of each of these four novel imaging techniques, as well as the rationale and implementation of QC procedures. Further, basic clinical applications and work flow issues will be discussed. Learning Objectives: To be able to describe the underlying physical and physiological principles of each imaging technique, and to understand the corresponding imaging acquisition process. To be able to describe the critical system components and their performance requirements. To understand the rationale and implementation of quality control procedures, as well as regulatory requirements for systems with FDA approval. To learn about clinical applications and understand risks and benefits/strength and weakness of each modality in terms of clinical breast imaging.« less

  20. Quantification of breast lesion compositions using low-dose spectral mammography: A feasibility study

    PubMed Central

    Ding, Huanjun; Sennung, David; Cho, Hyo-Min; Molloi, Sabee

    2016-01-01

    Purpose: The positive predictive power for malignancy can potentially be improved, if the chemical compositions of suspicious breast lesions can be reliably measured in screening mammography. The purpose of this study is to investigate the feasibility of quantifying breast lesion composition, in terms of water and lipid contents, with spectral mammography. Methods: Phantom and tissue samples were imaged with a spectral mammography system based on silicon-strip photon-counting detectors. Dual-energy calibration was performed for material decomposition, using plastic water and adipose-equivalent phantoms as the basis materials. The step wedge calibration phantom consisted of 20 calibration configurations, which ranged from 2 to 8 cm in thickness and from 0% to 100% in plastic water density. A nonlinear rational fitting function was used in dual-energy calibration of the imaging system. Breast lesion phantoms, made from various combinations of plastic water and adipose-equivalent disks, were embedded in a breast mammography phantom with a heterogeneous background pattern. Lesion phantoms with water densities ranging from 0% to 100% were placed at different locations of the heterogeneous background phantom. The water density in the lesion phantoms was measured using dual-energy material decomposition. The thickness and density of the background phantom were varied to test the accuracy of the decomposition technique in different configurations. In addition, an in vitro study was also performed using mixtures of lean and fat bovine tissue of 25%, 50%, and 80% lean weight percentages as the background. Lesions were simulated by using breast lesion phantoms, as well as small bovine tissue samples, composed of carefully weighed lean and fat bovine tissues. The water densities in tissue samples were measured using spectral mammography and compared to measurement using chemical decomposition of the tissue. Results: The thickness of measured and known water contents was

  1. Mammography dosimetry using an in-house developed polymethyl methacrylate phantom.

    PubMed

    Sharma, Reena; Sharma, Sunil Dutt; Mayya, Y S; Chourasiya, G

    2012-08-01

    Phantom-based measurements in mammography are well-established for quality assurance (QA) and quality control (QC) procedures involving equipment performance and comparisons of X-ray machines. Polymethyl methacrylate (PMMA) is among the best suitable materials for simulation of the breast. For carrying out QA/QC exercises in India, a mammographic PMMA phantom with engraved slots for keeping thermoluminescence dosemeters (TLD) has been developed. The radiation transmission property of the developed phantom was compared with the commercially available phantoms for verifying its suitability for mammography dosimetry. The breast entrance exposure (BEE), mean glandular dose (MGD), percentage depth dose (PDD), percentage surface dose distribution (PSDD), calibration testing of automatic exposure control (AEC) and density control function of a mammography machine were measured using this phantom. MGD was derived from the measured BEE following two different methodologies and the results were compared. The PDD and PSDD measurements were carried out using LiF: Mg, Cu, P chips. The in-house phantom was found comparable with the commercially available phantoms. The difference in the MGD values derived using two different methods were found in the range of 17.5-32.6 %. Measured depth ranges in the phantom lie between 0.32 and 0.40 cm for 75 % depth dose, 0.73 and 0.92 cm for 50 % depth dose, and 1.54 and 1.78 cm for 25 % depth dose. Higher PSDD value was observed towards chest wall edge side of the phantom, which is due to the orientation of cathode-anode axis along the chest wall to the nipple direction. Results obtained for AEC configuration testing shows that the observed mean optical density (O.D) of the phantom image was 1.59 and O.D difference for every successive increase in thickness of the phantom was within±0.15 O.D. Under density control function testing, at -2 and -1 density settings, the variation in film image O.D was within±0.15 O.D of the normal density

  2. Breast cancer stage at diagnosis and geographic access to mammography screening (New Hampshire, 1998–2004)

    PubMed Central

    Celaya, MO; Berke, EM; Onega, TL; Gui, J; Riddle, BL; Cherala, SS; Rees, JR

    2017-01-01

    Introduction Early detection of breast cancer by screening mammography aims to increase treatment options and decrease mortality. Recent studies have shown inconsistent results in their investigations of the possible association between travel distance to mammography and stage of breast cancer at diagnosis. Objective The purpose of the study was to investigate whether geographic access to mammography screening is associated with the stage at breast cancer diagnosis. Methods Using the state’s population-based cancer registry, all female residents of New Hampshire aged ≥40 years who were diagnosed with breast cancer during 1998–2004 were identified. The factors associated with early stage (stages 0 to 2) or later stage (stages 3 and 4) diagnosis of breast cancer were compared, with emphasis on the distance a woman lived from the closest mammography screening facility, and residence in rural and urban locations. Results A total of 5966 New Hampshire women were diagnosed with breast cancer during 1998–2004. Their mean driving distance to the nearest mammography facility was 8.85km (range 0–44.26; 5.5 miles, range 0–27.5), with a mean estimated travel time of 8.9 min (range 0.0–42.2). The distribution of travel distance (and travel time) was substantially skewed to the right: 56% of patients lived within 8 km (5 miles) of a mammography facility, and 65% had a travel time of less than 10 min. There was no significant association between later stage of breast cancer and travel time to the nearest mammography facility. Using 3 categories of rural/urban residence based on Rural Urban Commuting Area classification, no significant association between rural residence and stage of diagnosis was found. New Hampshire women were more likely to be diagnosed with breast cancer at later stages if they lacked private health insurance (p<0.001), were not married (p<0.001), were older (p<0.001), and there was a borderline association with diagnosis during non-winter months

  3. Digital mammography. Why hasn't it been approved for U.S. hospitals?

    PubMed

    2000-01-01

    Mammography is the only major imaging technique still unavailable in the United States in digital form. This is because the Food and Drug Administration (FDA) has been unable to devise an effective method for manufacturers to demonstrate the safety and efficacy of digital mammography systems. As a result, the agency has been unable to approve any of those systems for marketing in the United States. In this Regulatory Update, we describe FDA's recent efforts to help manufacturers obtain approval and the reasons those efforts have so far proved ineffective.

  4. Quantitative breast density analysis using tomosynthesis and comparison with MRI and digital mammography.

    PubMed

    Moon, Woo Kyung; Chang, Jie-Fan; Lo, Chung-Ming; Chang, Jung Min; Lee, Su Hyun; Shin, Sung Ui; Huang, Chiun-Sheng; Chang, Ruey-Feng

    2018-02-01

    Breast density at mammography has been used as markers of breast cancer risk. However, newly introduced tomosynthesis and computer-aided quantitative method could provide more reliable breast density evaluation. In the experiment, 98 tomosynthesis image volumes were obtained from 98 women. For each case, an automatic skin removal was used and followed by a fuzzy c-mean (FCM) classifier which separated the fibroglandular tissues from other tissues in breast area. Finally, percent of breast density and breast volume were calculated and the results were compared with MRI. In addition, the percent of breast density and breast area of digital mammography calculated using the software Cumulus (University of Toronto, Toronto, ON, Canada.) were also compared with 3-D modalities. Percent of breast density and breast volume, which were computed from tomosynthesis, MRI and digital mammography were 17.37% ± 4.39% and 607.12 cm 3  ± 323.01 cm 3 , 20.3% ± 8.6% and 537.59 cm 3  ± 287.74 cm 3 , and 12.03% ± 4.08%, respectively. There were significant correlations on breast density as well as volume between tomosynthesis and MRI (R = 0.482 and R = 0.805), tomosynthesis and breast density with breast area of digital mammography (R = 0.789 and R = 0.877), and MRI and breast density with breast area of digital mammography (R = 0.482 and R = 0.857) (all P values < .001). Breast density and breast volume evaluated from tomosynthesis, MRI and breast density and breast area of digital mammographic images have significant correlations and indicate that tomosynthesis could provide useful 3-D information on breast density through proposed method. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Motivators and barriers to mammography screening uptake by female health-care workers in primary health-care centres: a cross-sectional study.

    PubMed

    Nazzal, Zaher; Sholi, Hisham; Sholi, Suha B; Sholi, Mohammad B; Lahaseh, Rawya

    2018-02-21

    Mammography screening is an effective tool for early detection and management of breast cancer. Female health-care workers' awareness of breast cancer screening is important because their beliefs and behaviours could influence other women. The aim of this study was to assess mammography screening uptake by female health-care workers at primary health-care centres and to identify the primary motivators and barriers that affect uptake. This cross-sectional study included all governmental primary health-care centres in the West Bank. Governorates were grouped into three regions as follows: north West Bank (Nablus, Jenin, Tulkarm, Tubas, Qalqiliya, and Salfit), middle West Bank (Jerusalem, Jericho, and Ramallah), and south West Bank (Hebron, and Bethlehem). The study population included all female health-care workers older than 40 years. Those who performed mammography for a suspected mass or other breast abnormalities were excluded. A self-administered questionnaire was used to collect data on demographic characteristics, knowledge about mammography screening, the extent and regularity of mammography screening, and motivators and barriers influencing their mammography screening uptake. The rate of mammography screening uptake was calculated. χ 2 test and t tests were used to assess screening motivators and barriers. The study was approved by the Institutional Review Board of the An-Najah National University. Participation was voluntary, and written consent was obtained from each participant. 299 female health-care workers completed a self-administered questionnaire. The mean age of the participants was 46 years (SD 4·7). 284 (95%) women had adequate knowledge about breast cancer and mammography screening, and 149 (50%) women reported having had at least one mammogram. 62 (21%) women had had regular scheduled mammograms. The most frequent reported motivators were the perceived benefit that early detection of breast cancer is important for its management (269 [90

  6. Geographic access to mammography and its relationship to breast cancer screening and stage at diagnosis: a systematic review

    PubMed Central

    Khan-Gates, Jenna A.; Ersek, Jennifer L.; Eberth, Jan M.; Adams, Swann A.; Pruitt, Sandi

    2016-01-01

    Introduction A review was conducted to summarize the current evidence and gaps in the literature on geographic access to mammography and its relationship to breast cancer-related outcomes. Methods Ovid Medline and PubMed were searched for articles published between January 1, 2000 and April 1, 2013 using Medical Subject Headings and key terms representing geographic accessibility and breast cancer-related outcomes. Due to a paucity of breast cancer treatment and mortality outcomes meeting the criteria (N=6), outcomes were restricted to breast cancer screening and stage at diagnosis. Studies included one or more of the following types of geographic accessibility measures: capacity, density, distance and travel time. Study findings were grouped by outcome and type of geographic measure. Results Twenty-one articles met inclusion criteria. Fourteen articles included stage at diagnosis as an outcome, five included mammography utilization, and two included both. Geographic measures of mammography accessibility varied widely across studies. Findings also varied, but most articles found either increased geographic access to mammography associated with increased utilization and decreased late-stage at diagnosis or no statistically significant association. Conclusion The gaps and methodologic heterogeneity in the literature to date limit definitive conclusions about an underlying association between geographic mammography access and breast cancer-related outcomes. Future studies should focus on the development and application of more precise and consistent measures of geographic access to mammography. PMID:26219677

  7. Reproducing 2D breast mammography images with 3D printed phantoms

    NASA Astrophysics Data System (ADS)

    Clark, Matthew; Ghammraoui, Bahaa; Badal, Andreu

    2016-03-01

    Mammography is currently the standard imaging modality used to screen women for breast abnormalities and, as a result, it is a tool of great importance for the early detection of breast cancer. Physical phantoms are commonly used as surrogates of breast tissue to evaluate some aspects of the performance of mammography systems. However, most phantoms do not reproduce the anatomic heterogeneity of real breasts. New fabrication technologies, such as 3D printing, have created the opportunity to build more complex, anatomically realistic breast phantoms that could potentially assist in the evaluation of mammography systems. The primary objective of this work is to present a simple, easily reproducible methodology to design and print 3D objects that replicate the attenuation profile observed in real 2D mammograms. The secondary objective is to evaluate the capabilities and limitations of the competing 3D printing technologies, and characterize the x-ray properties of the different materials they use. Printable phantoms can be created using the open-source code introduced in this work, which processes a raw mammography image to estimate the amount of x-ray attenuation at each pixel, and outputs a triangle mesh object that encodes the observed attenuation map. The conversion from the observed pixel gray value to a column of printed material with equivalent attenuation requires certain assumptions and knowledge of multiple imaging system parameters, such as x-ray energy spectrum, source-to-object distance, compressed breast thickness, and average breast material attenuation. A detailed description of the new software, a characterization of the printed materials using x-ray spectroscopy, and an evaluation of the realism of the sample printed phantoms are presented.

  8. Prevalence and Determinants of Repeat Mammography Among Women from a Developing Country.

    PubMed

    Salinas-Martínez, Ana María; Gaspar-Rivera, Jimena Estefanía; Juárez-Pérez, Oscar; Montañez-Sauceda, José Roberto; Núñez-Rocha, Georgina Mayela; Guzmán-de-la-Garza, Francisco Javier; Mathiew-Quirós, Álvaro

    2017-04-01

    Failures in repeat mammography decrease the potential benefits of screening; however, it is notable that the recent use of mammography is more frequently studied than repeat use. We estimated the prevalence and analyzed determinants for repeat mammography among women from Mexico, a developing country of Latin America. It was a two-stage study with an initial cross-sectional design (n = 1045) and a final case-control design that involved women of at least 45 years of age with no history of breast, ovarian, or uterine cancer. Case subjects were those with three or more mammograms in the last 5 years, with the last one carried out within the last two years (n = 444); control subjects included those who underwent ≥3 mammograms throughout their life with the most recent carried out >2 years ago (n = 444). Through interviews, we evaluated context-dependency, fulfillment of expected outcomes, self-efficacy, and risk perception, among other factors. We estimated the prevalence with 95 % confidence intervals (CI), and odds ratios (OR) using multivariate binary logistic regression. The prevalence of repeat mammography was 40.4 % (95 % CI 37.4-43.4). Self-efficacy demonstrated the highest effect on repeat use (OR 7.7, 95 % CI 4.7-12.6), followed by awareness context-dependency (OR 4.9, 95 % CI 3.3-7.2), the use of Papanicolaou testing (OR 3.5, 95 % CI 2.3-5.2), the fulfillment of expected waiting time outcome (OR 2.4, 95 % CI 1.2-4.7), and context-dependency related to self-referral/health provider referral (OR 2.4, 95 % CI 1.7-3.4), independent of risk perception, age, education, and positive emotional state of mind. The study showed a need for increasing the prevalence of promoting awareness of the determining factors of repeat mammography, which is a necessary component in the early detection of breast cancer.

  9. Toward a standard reference database for computer-aided mammography

    NASA Astrophysics Data System (ADS)

    Oliveira, Júlia E. E.; Gueld, Mark O.; de A. Araújo, Arnaldo; Ott, Bastian; Deserno, Thomas M.

    2008-03-01

    Because of the lack of mammography databases with a large amount of codified images and identified characteristics like pathology, type of breast tissue, and abnormality, there is a problem for the development of robust systems for computer-aided diagnosis. Integrated to the Image Retrieval in Medical Applications (IRMA) project, we present an available mammography database developed from the union of: The Mammographic Image Analysis Society Digital Mammogram Database (MIAS), The Digital Database for Screening Mammography (DDSM), the Lawrence Livermore National Laboratory (LLNL), and routine images from the Rheinisch-Westfälische Technische Hochschule (RWTH) Aachen. Using the IRMA code, standardized coding of tissue type, tumor staging, and lesion description was developed according to the American College of Radiology (ACR) tissue codes and the ACR breast imaging reporting and data system (BI-RADS). The import was done automatically using scripts for image download, file format conversion, file name, web page and information file browsing. Disregarding the resolution, this resulted in a total of 10,509 reference images, and 6,767 images are associated with an IRMA contour information feature file. In accordance to the respective license agreements, the database will be made freely available for research purposes, and may be used for image based evaluation campaigns such as the Cross Language Evaluation Forum (CLEF). We have also shown that it can be extended easily with further cases imported from a picture archiving and communication system (PACS).

  10. Factors that influence mammography screening behaviour: a qualitative study of Greek women's experiences.

    PubMed

    Kaltsa, Aikaterina; Holloway, Aisha; Cox, Karen

    2013-06-01

    To identify the factors that influence mammography screening behaviour in a sample of Greek women. Data were collected in Athens-Greece, from individuals who were members of six women's associations. A subset of 33 women were interviewed about their screening behaviour and experiences out of the 186 women who completed an initial questionnaire. This paper focuses on the findings revealed from the interviews. Women's associations were approached for the recruitment of the interviewees. Influences arising from women's immediate networks, such as family and close friends, appeared to be of essential importance in relation to their screening behaviour, while influences from their broader networks were of moderate impact. Fear acted as a motivator but also as a barrier in relation to mammography screening participation. Experiences that arose from engagement with the mammography screening processes were mostly characterized by having to overcome a variety of obstacles, such as long bureaucratic procedures and distrust in doctors. The interpersonal relationships between women and their social networks appeared to have an important and influential role in relation to breast screening behaviour. The quality of these relationships appeared to determine women's participation in mammography screening. It would appear that future practice needs to focus on these relationships in order to utilize them in a positive way. Future research is needed to explore this further. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Mammography Screening Uptake among Female Health Care Workers in Primary Health Care Centers in Palestine - Motivators and Barriers.

    PubMed

    Nazzal, Zaher; Sholi, Hisham; Sholi, Suha; Sholi, Mohammad; Lahaseh, Rawya

    2016-01-01

    Early detection remains the cornerstone of breast cancer control in terms of outcome and survival. Thus far the only breast cancer screening method proven effective is mammography. The awareness of female health care workers (HCW) about breast cancer prevention is of vital importance, as their beliefs and behavior may have a major impact on other women. This study was designed to assess mammography screening uptake among female healthcare workers at primary healthcare centers, and to identify the primary motivators and barriers that affect uptake results. A cross sectional study design was used to assess mammography screening by 299 female healthcare workers who completed a self-administered questionnaire that assessed demographics, screening uptake, motivators and barriers. The mean age was 46 years (within age of risk). The majority (95.1%) demonstrated adequate knowledge about breast cancer and mammography screening and 50% of the participants reported having at least one mammogram; however only 21% of them had regularly scheduled mammograms. The most frequent reported motivator was the perceived benefit that early detection of breast cancer is important for its management (89.6%), followed by the belief that mammography can detect breast cancer before its symptoms appear (84.4%). On the other hand, the most frequent barrier reported was being busy (46.7%), followed by the lack of perceived susceptibility (41.5%). Mammography screening was found to be sub-optimal in a population of HCW's with 50 % stating that they received a mammogram at least once, and a minority reported regular screening. There is a pressing need for educational programs aimed at removing the barriers that limit compliance with recommendations for mammography screening, and to emphasize the importance of early detection in breast cancer treatment. Ensuring the availability and accessibility of screening services, particularly for healthcare workers within their work settings are other

  12. An interactive dynamic analysis and decision support software for MR mammography.

    PubMed

    Ertaş, Gökhan; Gülçür, H Ozcan; Tunaci, Mehtap

    2008-06-01

    A fully automated software is introduced to facilitate MR mammography (MRM) examinations and overcome subjectiveness in diagnosis using normalized maximum intensity-time ratio (nMITR) maps. These maps inherently suppress enhancements due to normal parenchyma and blood vessels that surround lesions and have natural tolerance to small field inhomogeneities and motion artifacts. The classifier embedded within the software is trained with normalized complexity and maximum nMITR of 22 lesions and tested with the features of remaining 22 lesions. Achieved diagnostic performances are 92% sensitivity, 90% specificity, 91% accuracy, 92% positive predictive value and 90% negative predictive value. DynaMammoAnalyst shortens evaluation time considerably and reduces inter and intra-observer variability by providing decision support.

  13. A comparison of the performance of digital mammography systems.

    PubMed

    Monnin, P; Gutierrez, D; Bulling, S; Guntern, D; Verdun, F R

    2007-03-01

    An objective analysis of image quality parameters was performed for six digital mammography systems. The presampled modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) for the systems were determined at different doses, for 28 kVp with a Mo/Mo or W/Al target/filter combination and 2 mm of additional aluminium filtration. The flat-panel units have higher MTF and DQE in the mid to high frequency range than standard CR systems. The highest DQE, over the whole dose range, is for the slit-scanning direct photon counting system. Dual-side read CR can overcome the inherent x-ray absorption and signal collection limitations of standard CR mammography, improving the low-frequency DQE by 40%, to the same level as full-field systems, but it does not improve the poor spatial resolution of phosphor.

  14. Evaluation of detector dynamic range in the x-ray exposure domain in mammography: a comparison between film-screen and flat panel detector systems.

    PubMed

    Cooper, Virgil N; Oshiro, Thomas; Cagnon, Christopher H; Bassett, Lawrence W; McLeod-Stockmann, Tyler M; Bezrukiy, Nikita V

    2003-10-01

    Digital detectors in mammography have wide dynamic range in addition to the benefit of decoupled acquisition and display. How wide the dynamic range is and how it compares to film-screen systems in the clinical x-ray exposure domain are unclear. In this work, we compare the effective dynamic ranges of film-screen and flat panel mammography systems, along with the dynamic ranges of their component image receptors in the clinical x-ray exposure domain. An ACR mammography phantom was imaged using variable mAs (exposure) values for both systems. The dynamic range of the contrast-limited film-screen system was defined as that ratio of mAs (exposure) values for a 26 kVp Mo/Mo (HVL=0.34 mm Al) beam that yielded passing phantom scores. The same approach was done for the noise-limited digital system. Data from three independent observers delineated a useful phantom background optical density range of 1.27 to 2.63, which corresponded to a dynamic range of 2.3 +/- 0.53. The digital system had a dynamic range of 9.9 +/- 1.8, which was wider than the film-screen system (p<0.02). The dynamic range of the film-screen system was limited by the dynamic range of the film. The digital detector, on the other hand, had an estimated dynamic range of 42, which was wider than the dynamic range of the digital system in its entirety by a factor of 4. The generator/tube combination was the limiting factor in determining the digital system's dynamic range.

  15. Cost-effectiveness of targeted versus tailored interventions to promote mammography screening among women military veterans in the United States.

    PubMed

    Lairson, David R; Chan, Wen; Chang, Yu-Chia; del Junco, Deborah J; Vernon, Sally W

    2011-05-01

    We conducted an economic evaluation of mammography promotion interventions in a population-based, nationally representative sample of 5500 women veterans. Women 52 years and older were randomly selected from the National Registry of Women Veterans and randomly assigned to a survey-only control group and two intervention groups that varied in the extent of personalization (tailored vs. targeted). Effectiveness measures were the prevalence of at least one self-reported post-intervention mammogram and two post-intervention mammograms 6-15 months apart. Incremental cost-effectiveness ratios (ICERs) were the incremental cost per additional person screened. Uncertainty was examined with sensitivity analysis and bootstrap simulation. The targeted intervention cost $25 per person compared to $52 per person for the tailored intervention. About 27% of the cost was incurred in identifying and recruiting the eligible population. The percent of women reporting at least one mammogram were .447 in the control group, .469 in the targeted group, and .460 in the tailored group. The ICER was $1116 comparing the targeted group to the control group (95% confidence interval (CI)=$493 to dominated). The tailored intervention was dominated (more costly and less effective) by the targeted intervention. Decision-makers should consider effectiveness evidence and the full recruitment and patient time costs associated with the implementation of screening interventions when making investments in mammography screening promotion programs. Identification and recruitment of eligible participants add substantial costs to outreach screening promotion interventions. Tailoring adds substantial cost to the targeted mammography promotion strategy without a commensurate increase in effectiveness. Although cost-effectiveness has been reported to be higher for some in-reach screening promotion interventions, a recent meta-analysis revealed significant heterogeneity in the effect sizes of published health

  16. Item Dependency in an Objective Structured Clinical Examination

    ERIC Educational Resources Information Center

    Iramaneerat, Cherdsak; Myford, Carol M.; Yudkowsky, Rachel

    2006-01-01

    An Objective Structured Clinical Examination (OSCE) is an assessment approach employed in medical education, in which residents rotate through multiple stations of standardized clinical tasks to evaluate their clinical competence. Because items used to evaluate residents' performance in each OSCE station are linked to the same task and are rated…

  17. Feasibility of generating quantitative composition images in dual energy mammography: a simulation study

    NASA Astrophysics Data System (ADS)

    Lee, Donghoon; Kim, Ye-seul; Choi, Sunghoon; Lee, Haenghwa; Choi, Seungyeon; Kim, Hee-Joung

    2016-03-01

    Breast cancer is one of the most common malignancies in women. For years, mammography has been used as the gold standard for localizing breast cancer, despite its limitation in determining cancer composition. Therefore, the purpose of this simulation study is to confirm the feasibility of obtaining tumor composition using dual energy digital mammography. To generate X-ray sources for dual energy mammography, 26 kVp and 39 kVp voltages were generated for low and high energy beams, respectively. Additionally, the energy subtraction and inverse mapping functions were applied to provide compositional images. The resultant images showed that the breast composition obtained by the inverse mapping function with cubic fitting achieved the highest accuracy and least noise. Furthermore, breast density analysis with cubic fitting showed less than 10% error compare to true values. In conclusion, this study demonstrated the feasibility of creating individual compositional images and capability of analyzing breast density effectively.

  18. Medical devices; radiology devices; reclassification of full-field digital mammography system. Final rule.

    PubMed

    2010-11-05

    The Food and Drug Administration (FDA) is announcing the reclassification of the full-field digital mammography (FFDM) system from class III (premarket approval) to class II (special controls). The device type is intended to produce planar digital x-ray images of the entire breast; this generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component parts, and accessories. The special control that will apply to the device is the guidance document entitled "Class II Special Controls Guidance Document: Full-Field Digital Mammography System." FDA is reclassifying the device into class II (special controls) because general controls along with special controls will provide a reasonable assurance of safety and effectiveness of the device. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document that will serve as the special control for this device.

  19. Do Clinical Breast Examination Skills Improve During Medical School?

    ERIC Educational Resources Information Center

    Lee, Karen C.; Dunlop, Dorothy; Dolan, Nancy C.

    1998-01-01

    A study assessed the effect of training stage, gender, and specialty interest on 493 Northwestern University (Illinois) medical students' breast cancer knowledge, attitudes, and clinical breast examination skills. Results suggest knowledge and attitudes are not related to clinical breast examination proficiency, which is a practiced tactile skill.…

  20. Digital tomosynthesis mammography using a parallel maximum-likelihood reconstruction method

    NASA Astrophysics Data System (ADS)

    Wu, Tao; Zhang, Juemin; Moore, Richard; Rafferty, Elizabeth; Kopans, Daniel; Meleis, Waleed; Kaeli, David

    2004-05-01

    A parallel reconstruction method, based on an iterative maximum likelihood (ML) algorithm, is developed to provide fast reconstruction for digital tomosynthesis mammography. Tomosynthesis mammography acquires 11 low-dose projections of a breast by moving an x-ray tube over a 50° angular range. In parallel reconstruction, each projection is divided into multiple segments along the chest-to-nipple direction. Using the 11 projections, segments located at the same distance from the chest wall are combined to compute a partial reconstruction of the total breast volume. The shape of the partial reconstruction forms a thin slab, angled toward the x-ray source at a projection angle 0°. The reconstruction of the total breast volume is obtained by merging the partial reconstructions. The overlap region between neighboring partial reconstructions and neighboring projection segments is utilized to compensate for the incomplete data at the boundary locations present in the partial reconstructions. A serial execution of the reconstruction is compared to a parallel implementation, using clinical data. The serial code was run on a PC with a single PentiumIV 2.2GHz CPU. The parallel implementation was developed using MPI and run on a 64-node Linux cluster using 800MHz Itanium CPUs. The serial reconstruction for a medium-sized breast (5cm thickness, 11cm chest-to-nipple distance) takes 115 minutes, while a parallel implementation takes only 3.5 minutes. The reconstruction time for a larger breast using a serial implementation takes 187 minutes, while a parallel implementation takes 6.5 minutes. No significant differences were observed between the reconstructions produced by the serial and parallel implementations.

  1. 21 CFR 892.1715 - Full-field digital mammography system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...

  2. 21 CFR 892.1715 - Full-field digital mammography system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...

  3. 21 CFR 892.1715 - Full-field digital mammography system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...

  4. 21 CFR 892.1715 - Full-field digital mammography system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...

  5. Degree of Enhancement on Contrast Enhanced Spectral Mammography (CESM) and Lesion Type on Mammography (MG): Comparison Based on Histological Results

    PubMed Central

    Łuczyńska, Elżbieta; Niemiec, Joanna; Hendrick, Edward; Heinze, Sylwia; Jaszczyński, Janusz; Jakubowicz, Jerzy; Sas-Korczyńska, Beata; Rys, Janusz

    2016-01-01

    Background Contrast enhanced spectral mammography (CESM) is a new method of breast cancer diagnosis in which an iodinated contrast agent is injected and dual-energy mammography is obtained in multiple views of the breasts. The aim of this study was to compare the degree of enhancement on CESM with lesion characteristics on mammography (MG) and lesion histology in women with suspicious breast lesions. Material/Methods The degree of enhancement on CESM (absent, weak, medium, or strong) was compared to lesion characteristics on MG (mass, mass with microcalcifications, or microcalcifications alone) and histology (infiltrating carcinoma, intraductal carcinoma, or benign) to compare sensitivity of the two modalities and to establish correlations that might improve diagnostic accuracy. Results Among 225 lesions identified with CESM and MG, histological evaluation revealed 143 carcinomas (127 infiltrating, 16 intraductal) and 82 benign lesions. This is the largest cohort investigated with CESM to date. The sensitivity of CESM was higher than that of MG (100% and 90%, respectively, p=0.010). Medium or strong enhancement on CESM and the presence of a mass on MG was the most likely indictor of malignancy (55.1% p=0.002). Among benign lesions, 60% presented as enhancement on CESM (were false-positive), and most frequently as medium or weak enhancement, together with a mass on MG (53%, p=0.047). Unfortunately, the study did not find combinations of MG findings and CESM enhancement patterns that would be helpful in defining false-positive lesions. We observed systematic overestimation of maximum lesion diameter on CESM compared to histology (mean difference: 2.29 mm). Conclusions Strong or medium enhancement on CESM and mass or mass with microcalcifications on MG were strong indicators of malignant transformation. However, we found no combination of MG and CESM characteristics helpful in defining false-positive lesions. PMID:27768681

  6. Degree of Enhancement on Contrast Enhanced Spectral Mammography (CESM) and Lesion Type on Mammography (MG): Comparison Based on Histological Results.

    PubMed

    Łuczyńska, Elżbieta; Niemiec, Joanna; Hendrick, Edward; Heinze, Sylwia; Jaszczyński, Janusz; Jakubowicz, Jerzy; Sas-Korczyńska, Beata; Rys, Janusz

    2016-10-21

    BACKGROUND Contrast enhanced spectral mammography (CESM) is a new method of breast cancer diagnosis in which an iodinated contrast agent is injected and dual-energy mammography is obtained in multiple views of the breasts. The aim of this study was to compare the degree of enhancement on CESM with lesion characteristics on mammography (MG) and lesion histology in women with suspicious breast lesions. MATERIAL AND METHODS The degree of enhancement on CESM (absent, weak, medium, or strong) was compared to lesion characteristics on MG (mass, mass with microcalcifications, or microcalcifications alone) and histology (infiltrating carcinoma, intraductal carcinoma, or benign) to compare sensitivity of the two modalities and to establish correlations that might improve diagnostic accuracy. RESULTS Among 225 lesions identified with CESM and MG, histological evaluation revealed 143 carcinomas (127 infiltrating, 16 intraductal) and 82 benign lesions. This is the largest cohort investigated with CESM to date. The sensitivity of CESM was higher than that of MG (100% and 90%, respectively, p=0.010). Medium or strong enhancement on CESM and the presence of a mass on MG was the most likely indictor of malignancy (55.1% p=0.002). Among benign lesions, 60% presented as enhancement on CESM (were false-positive), and most frequently as medium or weak enhancement, together with a mass on MG (53%, p=0.047). Unfortunately, the study did not find combinations of MG findings and CESM enhancement patterns that would be helpful in defining false-positive lesions. We observed systematic overestimation of maximum lesion diameter on CESM compared to histology (mean difference: 2.29 mm). CONCLUSIONS Strong or medium enhancement on CESM and mass or mass with microcalcifications on MG were strong indicators of malignant transformation. However, we found no combination of MG and CESM characteristics helpful in defining false-positive lesions.

  7. Contrast-enhanced digital mammography (CEDM): imaging modeling, computer simulations, and phantom study

    NASA Astrophysics Data System (ADS)

    Chen, Biao; Jing, Zhenxue; Smith, Andrew

    2005-04-01

    Contrast enhanced digital mammography (CEDM), which is based upon the analysis of a series of x-ray projection images acquired before/after the administration of contrast agents, may provide physicians critical physiologic and morphologic information of breast lesions to determine the malignancy of lesions. This paper proposes to combine the kinetic analysis (KA) of contrast agent uptake/washout process and the dual-energy (DE) contrast enhancement together to formulate a hybrid contrast enhanced breast-imaging framework. The quantitative characteristics of materials and imaging components in the x-ray imaging chain, including x-ray tube (tungsten) spectrum, filter, breast tissues/lesions, contrast agents (non-ionized iodine solution), and selenium detector, were systematically modeled. The contrast-noise-ration (CNR) of iodinated lesions and mean absorbed glandular dose were estimated mathematically. The x-ray techniques optimization was conducted through a series of computer simulations to find the optimal tube voltage, filter thickness, and exposure levels for various breast thicknesses, breast density, and detectable contrast agent concentration levels in terms of detection efficiency (CNR2/dose). A phantom study was performed on a modified Selenia full field digital mammography system to verify the simulated results. The dose level was comparable to the dose in diagnostic mode (less than 4 mGy for an average 4.2 cm compressed breast). The results from the computer simulations and phantom study are being used to optimize an ongoing clinical study.

  8. The tumour border on contrast-enhanced spectral mammography and its relation to histological characteristics of invasive breast cancer.

    PubMed

    Ambicka, Aleksandra; Luczynska, Elzbieta; Adamczyk, Agnieszka; Harazin-Lechowska, Agnieszka; Sas-Korczynska, Beata; Niemiec, Joanna

    Contrast-enhanced spectral mammography (CESM) is one of the new diagnostic modalities implemented in clinical practice. In the case of these techniques, there are two major issues to be addressed: (1) their diagnostic usefulness, and (2) the relation between parameters assessed using these techniques and well-known diagnostic/prognostic/predictive markers (histological, clinical, and molecular). Therefore, we studied the relationship between the tumour margin assessed on CESM and (1) tumour borders defined on the basis of macroscopic and microscopic examination, (2) pT, (3) pN, and (4) tumour grade in a group of 82 breast cancer patients. Based on CESM, the tumour border was defined as sharp, indistinct or spiculated, whereas in the case of lesions showing weak or medium enhancement on CESM the borders were classified as unspecified. We found a statistically significant relationship between tumour margin on CESM and (1) macroscopic border (a spiculated margin on CESM was found only in carcinomas with an invasive border on histological examination; p = 0.004), (2) pT (p = 0.016), and (3) pN (nodal involvement was observed most frequently in carcinomas with a spiculated or indistinct margin on CESM; p = 0.045). Moreover, in cases with an undefined margin on CESM (cases showing weak or medium enhancement on CESM), both invasive and pushing borders were found on histological examination. The results of our preliminary study suggest that it is possible to assess macroscopic borders of examined lesions on the basis of CESM imaging. This might be useful in planning the extent of surgical excision. On the other hand, the assessment of the tumour margin on CESM might not be precise in cases showing weak enhancement.

  9. Signal uniformity of mammography systems and its impact on test results from contrast detail phantoms

    NASA Astrophysics Data System (ADS)

    Kaar, M.; Semturs, F.; Hummel, J.; Hoffmann, R.; Figl, M.

    2015-03-01

    Technical quality assurance (TQA) procedures for mammography systems usually include tests with a contrast-detail phantom. These phantoms contain multiple objects of varying dimensions arranged on a flat body. Exposures of the phantom are then evaluated by an observer, either human or software. One well-known issue of this method is that dose distribution is not uniform across the image area of any mammography system, mainly due to the heel effect. The purpose of this work is to investigate to what extent image quality differs across the detector plane. We analyze a total of 320 homogeneous mammography exposures from 32 radiology institutes. Systems of different models and manufacturers, both computed radiography (CR) and direct radiography (DR) are included. All images were taken from field installations operated within the nationwide Austrian mammography screening program, which includes mandatory continuous TQA. We calculate signal-to-noise ratios (SNR) for 15 regions of interest arranged to cover the area of the phantom. We define the 'signal range' of an image and compare this value categorized by technologies. We found the deviations of SNR greater in anterior-posterior than in lateral direction. SNR ranges are significantly higher for CR systems than for DR systems.

  10. Automatic assessment of the quality of patient positioning in mammography

    NASA Astrophysics Data System (ADS)

    Bülow, Thomas; Meetz, Kirsten; Kutra, Dominik; Netsch, Thomas; Wiemker, Rafael; Bergtholdt, Martin; Sabczynski, Jörg; Wieberneit, Nataly; Freund, Manuela; Schulze-Wenck, Ingrid

    2013-02-01

    Quality assurance has been recognized as crucial for the success of population-based breast cancer screening programs using x-ray mammography. Quality guidelines and criteria have been defined in the US as well as the European Union in order to ensure the quality of breast cancer screening. Taplin et al. report that incorrect positioning of the breast is the major image quality issue in screening mammography. Consequently, guidelines and criteria for correct positioning and for the assessment of the positioning quality in mammograms play an important role in the quality standards. In this paper we present a system for the automatic evaluation of positioning quality in mammography according to the existing standardized criteria. This involves the automatic detection of anatomic landmarks in medio- lateral oblique (MLO) and cranio-caudal (CC) mammograms, namely the pectoral muscle, the mammilla and the infra-mammary fold. Furthermore, the detected landmarks are assessed with respect to their proper presentation in the image. Finally, the geometric relations between the detected landmarks are investigated to assess the positioning quality. This includes the evaluation whether the pectoral muscle is imaged down to the mammilla level, and whether the posterior nipple line diameter of the breast is consistent between the different views (MLO and CC) of the same breast. Results of the computerized assessment are compared to ground truth collected from two expert readers.

  11. Visualizing the Diffusion of Digital Mammography in New York State.

    PubMed

    Boscoe, Francis P; Zhang, Xiuling

    2017-04-01

    Background: Digital mammography saw rapid adoption during the first decade of the 2000s. We were interested in identifying the times and locations where the technology was introduced within the state of New York as a way of illustrating the uneven introduction of this technology. Methods: Using a sample of Medicare claims data from the period 2004 to 2012 from women ages 65 and over without cancer, we calculated the percentage of mammograms that were digital by zip code of residence and illustrated them with a series of smoothed maps. Results: Maps for three of the years (2005, 2008, and 2011) show the conversion from almost no digital mammography to nearly all digital mammography. The 2008 map reveals sharp disparities between areas that had and had not yet adopted the technology. Socioeconomic differences explain some of this pattern. Conclusions: Geographic disparities in access to medical technology are underappreciated relative to other sources of disparities. Our method provides a way of measuring and communicating this phenomenon. Impact: Our method could be applied to illuminate current examples, where access to medical technology is highly uneven, such as 3D tomography and robotic surgery. Cancer Epidemiol Biomarkers Prev; 26(4); 490-4. ©2017 AACR See all the articles in this CEBP Focus section, "Geospatial Approaches to Cancer Control and Population Sciences." ©2017 American Association for Cancer Research.

  12. Surveillance of Women with the BRCA1 or BRCA2 Mutation by Using Biannual Automated Breast US, MR Imaging, and Mammography.

    PubMed

    van Zelst, Jan C M; Mus, Roel D M; Woldringh, Gwendolyn; Rutten, Matthieu J C M; Bult, Peter; Vreemann, Suzan; de Jong, Mathijn; Karssemeijer, Nico; Hoogerbrugge, Nicoline; Mann, Ritse M

    2017-11-01

    Purpose To evaluate a multimodal surveillance regimen including yearly full-field digital (FFD) mammography, dynamic contrast agent-enhanced (DCE) magnetic resonance (MR) imaging, and biannual automated breast (AB) ultrasonography (US) in women with BRCA1 and BRCA2 mutations. Materials and Methods This prospective multicenter trial enrolled 296 carriers of the BRCA mutation (153 BRCA1 and 128 BRCA2 carriers, and 15 women with first-degree untested relatives) between September 2010 and November 2012, with follow-up until November 2015. Participants underwent 2 years of intensified surveillance including biannual AB US, and routine yearly DCE MR imaging and FFD mammography. The surveillance performance for each modality and possible combinations were determined. Results Breast cancer was screening-detected in 16 women (age range, 33-58 years). Three interval cancers were detected by self-examination, all in carriers of the BRCA1 mutation under age 43 years. One cancer was detected in a carrier of the BRCA1 mutation with a palpable abnormality in the contralateral breast. One incidental breast cancer was detected in a prophylactic mastectomy specimen. Respectively, sensitivity of DCE MR imaging, FFD mammography, and AB US was 68.1% (14 of 21; 95% confidence interval [CI]: 42.9%, 85.8%), 37.2% (eight of 21; 95% CI: 19.8%, 58.7%), and 32.1% (seven of 21; 95% CI: 16.1%, 53.8%); specificity was 95.0% (643 of 682; 95% CI: 92.7%, 96.5%), 98.1% (638 of 652; 95% CI: 96.7%, 98.9%), and 95.1% (1030 of 1088; 95% CI: 93.5%, 96.3%); cancer detection rate was 2.0% (14 of 702), 1.2% (eight of 671), and 1.0% (seven of 711) per 100 women-years; and positive predictive value was 25.2% (14 of 54), 33.7% (nine of 23), and 9.5% (seven of 68). DCE MR imaging and FFD mammography combined yielded the highest sensitivity of 76.3% (16 of 21; 95% CI: 53.8%, 89.9%) and specificity of 93.6% (643 of 691; 95% CI: 91.3%, 95.3%). AB US did not depict additional cancers. FFD mammography yielded no

  13. Digital mammography: physical principles and future applications.

    PubMed

    Gambaccini, Mauro; Baldelli, Paola

    2003-01-01

    Mammography is currently considered the best tool for the detection of breast cancer, pathology with a rate of incidence in constant increase. To produce the radiological picture a screen film combination is conventionally used. One of the inherent limitations of screen- film combination is the fact that the detection, display and storage processes are one and the same, making it impossible to separately optimize each stage. These limitations can be overcome with digital systems. In this work we evaluate the main characteristics of digital detectors available on the market and we compare the performance of digital and conventional systems. Digital mammography, due to the possibility to process images, offers many potential advantages, among these the possibility to introduce the dual-energy technique which employs the composition of two digital images obtained with two different energies to enhance the inherent contrast of pathologies by removing the uniform background. This technique was previously tested by using synchrotron monochromatic beam and a digital detector, and then the Senographe 2000D full-field digital system manufactured by GE Medical Systems. In this work we present preliminary results and the future applications of this technique.

  14. Readability assessment of internet-based patient education materials related to mammography for breast cancer screening.

    PubMed

    AlKhalili, Rend; Shukla, Pratik A; Patel, Ronak H; Sanghvi, Saurin; Hubbi, Basil

    2015-03-01

    The US Department of Health and Human Services (USDHHS) recommends that Internet-based patient education materials (IPEMs) be written below the sixth-grade reading level to target the average American adult. This study was designed to determine the readability of IPEMs regarding mammography for breast cancer screening. Three-hundred mammography-related Web sites were reviewed for IPEMs. Forty-two IPEMs that met the Health on the Net Foundation Code of Conduct were assessed for readability level with four readability indices that use existing algorithms based on word and sentence length to quantitatively analyze Internet sources for language intricacy including the following: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG; GFOG). Results were compared to national recommendations, and intergroup analysis was performed. No IPEMs (0%) regarding mammography were written at or below the sixth-grade reading level, based on FKGL. The mean readability scores were as follows: FRES, 49.04 ± 10.62; FKGL, 10.71 ± 2.01; SMOG, 13.33 ± 1.67; and Gunning FOG, 14.32 ± 2.18. These scores indicate that the readability of mammography IPEMs is written at a "difficult" level, significantly above the recommended sixth-grade reading level (P < .05) determined by the USDHHS. IPEMs related to mammography are written well above the recommended sixth-grade level and likely reflect other IPEMs in diagnostic radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  15. Diffusion weighted imaging with background body signal suppression / T2 image fusion in magnetic resonance mammography for breast cancer diagnosis.

    PubMed

    Nechifor-Boilă, I A; Bancu, S; Buruian, M; Charlot, M; Decaussin-Petrucci, M; Krauth, J-S; Nechifor-Boilă, A C; Borda, A

    2013-01-01

    Dynamic Contrast-Enhanced Magnetic Resonance Mammography (DCE-MRM) represents the most sensitive examination for breast cancer (BC) diagnosis. However literature data reports very inhomogeneous specificity. The aim of our study was to evaluate the clinical efficiency of a new MRM technique - diffusion weighted imaging with background body signal suppression T2 image fusion in BC diagnosis, compared to DCE-MRM. We retrospectively analyzed 50 consecutive DCE-MRM examinations with DWIBS sequence from the archives of the Department of Radiology, Lyon Sud Hospital, (02.2010- 02.2011), summing up to 64 breast lesions. Fusions were created using the Osirix software from the DWIBS images (b=1000 s mm2) and their T2 correspondents. Interpretation was performed using an adapted BI-RADS system. The final histopathological examination or a minimum 6-months follow-up served as gold standard. Out of the 64 examined breast lesions, 35(54.7%) were classified as malignant by DCE-MRM and 24(37.5%) cases by DWIBS T2, respectively. Thus the DWIBS T2 fusion had a Sensitivity of 62.5%(95%CI:35.4-84.8) and a Specificity of 70.8%(95%CI:55.9-83.3) while DCE-MRM had a higher Sensitivity: 87.5%(95%CI:61.6-98.4) but a lower Specificity: 56.2%(95%CI:41.1-70.5). DWIBS T2 fusion is an innovative MRM technique, with a specificity superior to DCE-MRM, showing a large potential for improving the clinical efficiency of classical MRM. Celsius.

  16. Competitive testing of health behavior theories: how do benefits, barriers, subjective norm, and intention influence mammography behavior?

    PubMed Central

    Murphy, Caitlin C.; Vernon, Sally W.; Diamond, Pamela M.; Tiro, Jasmin A.

    2013-01-01

    Background Competitive hypothesis testing may explain differences in predictive power across multiple health behavior theories. Purpose We tested competing hypotheses of the Health Belief Model (HBM) and Theory of Reasoned Action (TRA) to quantify pathways linking subjective norm, benefits, barriers, intention, and mammography behavior. Methods We analyzed longitudinal surveys of women veterans randomized to the control group of a mammography intervention trial (n=704). We compared direct, partial mediation, and full mediation models with Satorra-Bentler χ2 difference testing. Results Barriers had a direct and indirect negative effect on mammography behavior; intention only partially mediated barriers. Benefits had little to no effect on behavior and intention; however, it was negatively correlated with barriers. Subjective norm directly affected behavior and indirectly affected intention through barriers. Conclusions Our results provide empiric support for different assertions of HBM and TRA. Future interventions should test whether building subjective norm and reducing negative attitudes increases regular mammography. PMID:23868613

  17. Light sensitometry of mammography films at varying development temperatures and times

    PubMed Central

    Sharma, Reena; Sharma, Sunil Dutt; Mayya, Y. S.

    2012-01-01

    Kodak MinR-2000 mammography film is widely used for mammography imaging. The sensitometric indices like base plus fog level (B + F), maximum optical density (ODmax), average gradient (AG) and speed of this film at varying development temperatures and times were evaluated using a light sensitometer. Totally 33 film strips were cut from a single Kodak MinR-2000 mammography film box and exposed in a light sensitometer operated in the green light spectrum to produce a 21-step sensitometric strip. These exposed film strips were processed at temperatures in the range of 32°C–37°C in the step of 1°C and at processing times in the range of 1–6 minutes in the step of 1 minute. The results of the present study show that the measured base plus fog level of the mammography film was not affected much, whereas significant changes were seen in the ODmax, AG and speed with varying development temperatures and times. The ODmax values of the film were found in the range of 3.67–3.76, AG values were in the range of 2.48–3.4 and speed values were in the range of 0.015–0.0236 when the processing temperature was varied from 32°C to 37°C. With processing time variation from 1 to 6 minutes, the observed changes in ODmax values were in the range of 3.54-3.71, changes in AG were in the range of 2.66–3.27 and changes in speed were in the range of 0.011–0.025. Based on these observations, recommendations for optimum processing parameters to be used for this film are made. PMID:22363111

  18. Prediction of near-term breast cancer risk using local region-based bilateral asymmetry features in mammography

    NASA Astrophysics Data System (ADS)

    Li, Yane; Fan, Ming; Li, Lihua; Zheng, Bin

    2017-03-01

    This study proposed a near-term breast cancer risk assessment model based on local region bilateral asymmetry features in Mammography. The database includes 566 cases who underwent at least two sequential FFDM examinations. The `prior' examination in the two series all interpreted as negative (not recalled). In the "current" examination, 283 women were diagnosed cancers and 283 remained negative. Age of cancers and negative cases completely matched. These cases were divided into three subgroups according to age: 152 cases among the 37-49 age-bracket, 220 cases in the age-bracket 50- 60, and 194 cases with the 61-86 age-bracket. For each image, two local regions including strip-based regions and difference-of-Gaussian basic element regions were segmented. After that, structural variation features among pixel values and structural similarity features were computed for strip regions. Meanwhile, positional features were extracted for basic element regions. The absolute subtraction value was computed between each feature of the left and right local-regions. Next, a multi-layer perception classifier was implemented to assess performance of features for prediction. Features were then selected according stepwise regression analysis. The AUC achieved 0.72, 0.75 and 0.71 for these 3 age-based subgroups, respectively. The maximum adjustable odds ratios were 12.4, 20.56 and 4.91 for these three groups, respectively. This study demonstrate that the local region-based bilateral asymmetry features extracted from CC-view mammography could provide useful information to predict near-term breast cancer risk.

  19. Engaging diverse underserved communities to bridge the mammography divide

    PubMed Central

    2011-01-01

    Background Breast cancer screening continues to be underutilized by the population in general, but is particularly underutilized by traditionally underserved minority populations. Two of the most at risk female minority groups are American Indians/Alaska Natives (AI/AN) and Latinas. American Indian women have the poorest recorded 5-year cancer survival rates of any ethnic group while breast cancer is the number one cause of cancer mortality among Latina women. Breast cancer screening rates for both minority groups are near or at the lowest among all racial/ethnic groups. As with other health screening behaviors, women may intend to get a mammogram but their intentions may not result in initiation or follow through of the examination process. An accumulating body of research, however, demonstrates the efficacy of developing 'implementation intentions' that define when, where, and how a specific behavior will be performed. The formulation of intended steps in addition to addressing potential barriers to test completion can increase a person's self-efficacy, operationalize and strengthen their intention to act, and close gaps between behavioral intention and completion. To date, an evaluation of the formulation of implementation intentions for breast cancer screening has not been conducted with minority populations. Methods/Design In the proposed program, community health workers will meet with rural-dwelling Latina and American Indian women one-on-one to educate them about breast cancer and screening and guide them through a computerized and culturally tailored "implementation intentions" program, called Healthy Living Kansas - Breast Health, to promote breast cancer screening utilization. We will target Latina and AI/AN women from two distinct rural Kansas communities. Women attending community events will be invited by CHWs to participate and be randomized to either a mammography "implementation intentions" (MI2) intervention or a comparison general breast cancer

  20. Quality assurance in mammography: College of Radiology Survey in Malaysia.

    PubMed

    Ho, E L M; Ng, K H; Wong, J H D; Wang, H B

    2006-06-01

    Malaysia's mammography QA practice was surveyed based on the Malaysian Ministry of Health and the American College of Radiology (ACR) requirements. Data on mammography unit, processor, image receptor, exposure factors, mean glandular dose (MGD), sensitometry, image quality and viewbox luminance were obtained. Mean developer temperature and cycle time were 34.1 +/- 1.8degreesC and 107.7 +/- 33.2 seconds. Mean base+fog level, speed index and contrast index were 0.20+/-0.01, 1.20+/-0.01 and 1.33+/-0.26 respectively. Eighty-six percent of the fifty centres passed the image quality test while 12.5% complied with ACR recommended viewbox luminance. Average MGD was 1.0+/-0.4 mGy. Malaysia is on the right track for QA but with room for total quality improvement.

  1. Comparison of Clinical and Automated Breast Density Measurements: Implications for Risk Prediction and Supplemental Screening

    PubMed Central

    Brandt, Kathleen R.; Scott, Christopher G.; Ma, Lin; Mahmoudzadeh, Amir P.; Jensen, Matthew R.; Whaley, Dana H.; Wu, Fang Fang; Malkov, Serghei; Hruska, Carrie B.; Norman, Aaron D.; Heine, John; Shepherd, John; Pankratz, V. Shane; Kerlikowske, Karla

    2016-01-01

    Purpose To compare the classification of breast density with two automated methods, Volpara (version 1.5.0; Matakina Technology, Wellington, New Zealand) and Quantra (version 2.0; Hologic, Bedford, Mass), with clinical Breast Imaging Reporting and Data System (BI-RADS) density classifications and to examine associations of these measures with breast cancer risk. Materials and Methods In this study, 1911 patients with breast cancer and 4170 control subjects matched for age, race, examination date, and mammography machine were evaluated. Participants underwent mammography at Mayo Clinic or one of four sites within the San Francisco Mammography Registry between 2006 and 2012 and provided informed consent or a waiver for research, in compliance with HIPAA regulations and institutional review board approval. Digital mammograms were retrieved a mean of 2.1 years (range, 6 months to 6 years) before cancer diagnosis, with the corresponding clinical BI-RADS density classifications, and Volpara and Quantra density estimates were generated. Agreement was assessed with weighted κ statistics among control subjects. Breast cancer associations were evaluated with conditional logistic regression, adjusted for age and body mass index. Odds ratios, C statistics, and 95% confidence intervals (CIs) were estimated. Results Agreement between clinical BI-RADS density classifications and Volpara and Quantra BI-RADS estimates was moderate, with κ values of 0.57 (95% CI: 0.55, 0.59) and 0.46 (95% CI: 0.44, 0.47), respectively. Differences of up to 14% in dense tissue classification were found, with Volpara classifying 51% of women as having dense breasts, Quantra classifying 37%, and clinical BI-RADS assessment used to classify 43%. Clinical and automated measures showed similar breast cancer associations; odds ratios for extremely dense breasts versus scattered fibroglandular densities were 1.8 (95% CI: 1.5, 2.2), 1.9 (95% CI: 1.5, 2.5), and 2.3 (95% CI: 1.9, 2.8) for Volpara, Quantra

  2. Effects of basic clinical skills training on objective structured clinical examination performance.

    PubMed

    Jünger, Jana; Schäfer, Sybille; Roth, Christiane; Schellberg, Dieter; Friedman Ben-David, Miriam; Nikendei, Christoph

    2005-10-01

    The aim of curriculum reform in medical education is to improve students' clinical and communication skills. However, there are contradicting results regarding the effectiveness of such reforms. A study of internal medicine students was carried out using a static group design. The experimental group consisted of 77 students participating in 7 sessions of communication training, 7 sessions of skills-laboratory training and 7 sessions of bedside-teaching, each lasting 1.5 hours. The control group of 66 students from the traditional curriculum participated in equally as many sessions but was offered only bedside teaching. Students' cognitive and practical skills performance was assessed using Multiple Choice Question (MCQ) testing and an objective structured clinical examination (OSCE), delivered by examiners blind to group membership. The experimental group performed significantly better on the OSCE than did the control group (P < 0.01), whereas the groups did not differ on the MCQ test (P < 0.15). This indicates that specific training in communication and basic clinical skills enabled students to perform better in an OSCE, whereas its effects on knowledge did not differ from those of the traditional curriculum. Curriculum reform promoting communication and basic clinical skills are effective and lead to an improved performance in history taking and physical examination skills.

  3. Health-related quality of life, anxiety and depression related to mammography screening in Norway.

    PubMed

    Hafslund, Bjorg; Espehaug, Birgitte; Nortvedt, Monica Wammen

    2012-11-01

    To measure health-related quality of life, anxiety and depression ahead of mammography screening and to assess any differences in health-related quality of life compared to reference population. The study of health-related quality of life among attendees prior to mammography screening has received little attention, and increased knowledge is needed to better understand the overall health benefits of participation. A two-group cross-sectional comparative study was performed. The samples comprised 4,249 attendees to mammography screening and a comparison group of 943 women. We used the SF-36 Health Survey to assess health-related quality of life. Linear regression was used to study any differences between the groups with adjustment for age, level of education, occupation, having children and smoking status. Other normative data were also used. Anxiety and depression were assessed using the Hospital Anxiety and Depression Scale. Attendees scored statistically significant higher on the SF-36 than the comparison group but were in line with normative data. Attendees had anxiety mean 4·1 and depression mean 2·6. The majority of the attendees have a high health-related quality of life, low anxiety and depression ahead of screening. Anxiety and depression were less than shown in normative data from Norway. Despite a high health-related quality of life, low anxiety and depression among the majority, healthcare workers should pay special attention to the few women who are anxious and depressed, and have a lower health-related quality of life. Omitted from mammography screening may be women who are unemployed, have lower socioeconomic status, are anxious and are depressed. Further research should be performed with non-attendees and subgroups to improve the screening programme. It is important to identify which patients have the greatest need for support and caring in an organised mammography screening and who may be overlooked. © 2012 Blackwell Publishing Ltd.

  4. Breast Cancer Risk Prediction and Mammography Biopsy Decisions

    PubMed Central

    Armstrong, Katrina; Handorf, Elizabeth A.; Chen, Jinbo; Demeter, Mirar N. Bristol

    2012-01-01

    Background Controversy continues about screening mammography, in part because of the risk of false-negative and false-positive mammograms. Pre-test breast cancer risk factors may improve the positive and negative predictive value of screening. Purpose To create a model that estimates the potential impact of pre-test risk prediction using clinical and genomic information on the reclassification of women with abnormal mammograms (BI-RADS3 and BI-RADS4 [Breast Imaging-Reporting and Data System]) above and below the threshold for breast biopsy. Methods The current study modeled 1-year breast cancer risk in women with abnormal screening mammograms using existing data on breast cancer risk factors, 12 validated breast cancer single nucleotide polymorphisms (SNPs), and probability of cancer given the BI-RADS category. Examination was made of reclassification of women above and below biopsy thresholds of 1%, 2%, and 3% risk. The Breast Cancer Surveillance Consortium data were collected from 1996 to 2002. Data analysis was conducted in 2010 and 2011. Results Using a biopsy risk threshold of 2% and the standard risk factor model, 5% of women with a BI-RADS3 mammogram had a risk above the threshold, and 3% of women with BIRADS4A mammograms had a risk below the threshold. The addition of 12 SNPs in the model resulted in 8% of women with a BI-RADS3 mammogram above the threshold for biopsy and 7% of women with BI-RADS4A mammograms below the threshold. Conclusions The incorporation of pre-test breast cancer risk factors could change biopsy decisions for a small proportion of women with abnormal mammograms. The greatest impact comes from standard breast cancer risk factors. PMID:23253645

  5. Decision-Making Regarding Mammography Screening for Older Women.

    PubMed

    Schonberg, Mara A

    2016-12-01

    The population is aging, and breast cancer incidence increases with age, peaking between the ages of 75 and 79. However, it is not known whether mammography screening helps women aged 75 and older live longer because they have not been included in randomized controlled trials evaluating mammography screening. Guidelines recommend that older women with less than a 10-year life expectancy not be screened because it takes approximately 10 years before a screen-detected breast cancer may affect an older woman's survival. Guidelines recommend that clinicians discuss the benefits and risks of screening with women aged 75 and older with a life expectancy of 10 years or longer to help them elicit their values and preferences. It is estimated that two of 1,000 women who continue to be screened every other year from age 70 to 79 may avoid breast cancer death, but 12% to 27% of these women will experience a false-positive test, and 10% to 20% of women who experience a false-positive test will undergo a breast biopsy. In addition, approximately 30% of screen-detected cancers would not otherwise have shown up in an older woman's lifetime, yet nearly all older women undergo treatment for these breast cancers, and the risks of treatment increase with age. To inform decision-making, tools are available to estimate life expectancy and to educate older women about the benefits and harms of mammography screening. Guides are also available to help clinicians discuss stopping screening with older women with less than a 10-year life expectancy. Ideally, screening decisions would consider an older woman's life expectancy, breast cancer risk, and her values and preferences. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  6. Timeliness of abnormal screening and diagnostic mammography follow-up at facilities serving vulnerable women.

    PubMed

    Goldman, L Elizabeth; Walker, Rod; Hubbard, Rebecca; Kerlikowske, Karla

    2013-04-01

    Whether timeliness of follow-up after abnormal mammography differs at facilities serving vulnerable populations, such as women with limited education or income, in rural areas, and racial/ethnic minorities is unknown. We examined receipt of diagnostic evaluation after abnormal mammography using 1998-2006 Breast Cancer Surveillance Consortium-linked Medicare claims. We compared whether time to recommended breast imaging or biopsy depended on whether women attended facilities serving vulnerable populations. We characterized a facility by the proportion of mammograms performed on women with limited education or income, in rural areas, or racial/ethnic minorities. We analyzed 30,874 abnormal screening examinations recommended for follow-up imaging across 142 facilities and 10,049 abnormal diagnostic examinations recommended for biopsy across 114 facilities. Women at facilities serving populations with less education or more racial/ethnic minorities had lower rates of follow-up imaging (4%-5% difference, P<0.05), and women at facilities serving more rural and low-income populations had lower rates of biopsy (4%-5% difference, P<0.05). Women undergoing biopsy at facilities serving vulnerable populations had longer times until biopsy than those at facilities serving nonvulnerable populations (21.6 vs. 15.6 d; 95% confidence interval for mean difference 4.1-7.7). The proportion of women receiving recommended imaging within 11 months and biopsy within 3 months varied across facilities (interquartile range, 85.5%-96.5% for imaging and 79.4%-87.3% for biopsy). Among Medicare recipients, follow-up rates were slightly lower at facilities serving vulnerable populations, and among those women who returned for diagnostic evaluation, time to follow-up was slightly longer at facilities that served vulnerable population. Interventions should target variability in follow-up rates across facilities, and evaluate effectiveness particularly at facilities serving vulnerable populations.

  7. Timeliness of abnormal screening and diagnostic mammography follow-up at facilities serving vulnerable women

    PubMed Central

    Goldman, L. Elizabeth; Walker, Rod; Hubbard, Rebecca; Kerlikowske, Karla

    2013-01-01

    Background Whether timeliness of follow-up after abnormal mammography differs at facilities serving vulnerable populations such as women with limited education or income, in rural areas, and racial/ethnic minorities is unknown. Methods We examined receipt of diagnostic evaluation following abnormal mammography using 1998-2006 Breast Cancer Surveillance Consortium-linked Medicare claims. We compared whether time to recommended breast imaging or biopsy depended on whether women attended facilities serving vulnerable populations. We characterized a facility by the proportion of mammograms performed on women with limited education or income, in rural areas, or racial/ethnic minorities. Results We analyzed 30,874 abnormal screening examinations recommended for follow-up imaging across 142 facilities and 10,049 abnormal diagnostic examinations recommended for biopsy across 114 facilities. Women at facilities serving populations with less education or more racial/ethnic minorities had lower rates of follow-up imaging (4-5% difference, p<0.05), and women at facilities serving more rural and low income populations had lower rates of biopsy (4-5% difference, p<0.05). Women undergoing biopsy at facilities serving vulnerable populations had longer times until biopsy than those at facilities serving non-vulnerable populations (21.6 days vs. 15.6 days; 95% CI for mean difference 4.1-7.7). The proportion of women receiving recommended imaging within 11 months and biopsy within 3 months varied across facilities (interquartile range 85.5%-96.5% for imaging and 79.4%-87.3% for biopsy). Conclusions Among Medicare recipients, follow-up rates were slightly lower at facilities serving vulnerable populations, and among those women who returned for diagnostic evaluation, time to follow-up was slightly longer at facilities that served vulnerable population. Interventions should target variability in follow-up rates across facilities, and evaluate effectiveness particularly at facilities

  8. Does the Neighborhood Area of Residence Influence Non-Attendance in an Urban Mammography Screening Program? A Multilevel Study in a Swedish City

    PubMed Central

    Lagerlund, Magdalena; Merlo, Juan; Vicente, Raquel Pérez; Zackrisson, Sophia

    2015-01-01

    Background and aim The public health impact of population-based mammography screening programs depends on high participation rates. Thus, monitoring participation rates, as well as understanding and considering the factors influencing attendance, is important. With the goal to acquire information on the appropriate level of intervention for increasing screening participation our study aimed to (1) examine whether, over and above individual factors, the neighborhood of residence influences a woman’s mammography non-attendance, and (2) evaluate, whether knowing a woman’s neighborhood of residence would be sufficient to predict non-attendance. Methods We analyze all women invited to mammography screening in 2005–09, residing in the city of Malmö, Sweden. Information regarding mammography screening attendance was linked to data on area of residence, demographic and socioeconomic characteristics available from Statistics Sweden. The influence of individual and neighborhood factors was assessed by multilevel logistic regression analysis with 29,901 women nested within 212 neighborhoods. Results The prevalence of non-attendance among women was 18.3%. After adjusting for individual characteristics, the prevalence in the 212 neighborhoods was 3.6%. Neighborhood of residence had little influence on non-attendance. The multilevel analysis indicates that 8.4% of the total individual differences in the propensity of non-attendance were at the neighborhood level. However, when adjusting for specific individual characteristics this general contextual effect decreased to 1.8%. This minor effect was explained by the sociodemographic characteristic of the neighborhoods. The discriminatory accuracy of classifying women according to their non-attendance was 0.747 when considering only individual level variables, and 0.760 after including neighborhood level as a random effect. Conclusion Our results suggest that neighborhoods of residence in Malmö, Sweden (as defined by small

  9. American Society of Clinical Oncology 2006 update of the breast cancer follow-up and management guidelines in the adjuvant setting.

    PubMed

    Khatcheressian, James L; Wolff, Antonio C; Smith, Thomas J; Grunfeld, Eva; Muss, Hyman B; Vogel, Victor G; Halberg, Francine; Somerfield, Mark R; Davidson, Nancy E

    2006-11-01

    To update the 1999 American Society of Clinical Oncology (ASCO) guideline on breast cancer follow-up and management in the adjuvant setting. An ASCO Expert Panel reviewed pertinent information from the literature through March 2006. More weight was given to studies that tested a hypothesis directly relating testing to one of the primary outcomes in a randomized design. The evidence supports regular history, physical examination, and mammography as the cornerstone of appropriate breast cancer follow-up. All patients should have a careful history and physical examination performed by a physician experienced in the surveillance of cancer patients and in breast examination. Examinations should be performed every 3 to 6 months for the first 3 years, every 6 to 12 months for years 4 and 5, and annually thereafter. For those who have undergone breast-conserving surgery, a post-treatment mammogram should be obtained 1 year after the initial mammogram and at least 6 months after completion of radiation therapy. Thereafter, unless otherwise indicated, a yearly mammographic evaluation should be performed. Patients at high risk for familial breast cancer syndromes should be referred for genetic counseling. The use of CBCs, chemistry panels, bone scans, chest radiographs, liver ultrasounds, computed tomography scans, [18F]fluorodeoxyglucose-positron emission tomography scanning, magnetic resonance imaging, or tumor markers (carcinoembryonic antigen, CA 15-3, and CA 27.29) is not recommended for routine breast cancer follow-up in an otherwise asymptomatic patient with no specific findings on clinical examination. Careful history taking, physical examination, and regular mammography are recommended for appropriate detection of breast cancer recurrence.

  10. Breast Volume Measurement by Recycling the Data Obtained From 2 Routine Modalities, Mammography and Magnetic Resonance Imaging.

    PubMed

    Itsukage, Shizu; Sowa, Yoshihiro; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki

    2017-01-01

    Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes' principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging.

  11. Breast Volume Measurement by Recycling the Data Obtained From 2 Routine Modalities, Mammography and Magnetic Resonance Imaging

    PubMed Central

    Itsukage, Shizu; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki

    2017-01-01

    Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes’ principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging. PMID:29308107

  12. Newly Diagnosed Breast Cancer: Comparison of Contrast-enhanced Spectral Mammography and Breast MR Imaging in the Evaluation of Extent of Disease.

    PubMed

    Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita

    2017-11-01

    Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P < .001 for all results). In addition, contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of

  13. A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme.

    PubMed

    Gennaro, G; Ballaminut, A; Contento, G

    2017-09-01

    This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.

  14. High-rate x-ray spectroscopy in mammography with a CdTe detector: a digital pulse processing approach.

    PubMed

    Abbene, L; Gerardi, G; Principato, F; Del Sordo, S; Ienzi, R; Raso, G

    2010-12-01

    Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the response of the digital detection system both at low (150 cps) and at high photon counting rates (up to 500 kcps) by using monoenergetic x-ray sources and a nonclinical molybdenum anode x-ray tube. Clinical molybdenum x-ray spectrum measurements were also performed by using a pinhole collimator and a custom alignment device. The detection system shows excellent performance up to 512 kcps with an energy resolution of 4.08% FWHM at 22.1 keV. Despite the high photon counting rate (up to 453 kcps), the molybdenum x-ray spectra, measured under clinical conditions, are characterized by a low number of pile-up events. The agreement between the attenuation curves and the half value layer values, obtained from the measured spectra, simulated spectra, and from the exposure values directly measured with an ionization chamber, also shows the accuracy of the measurements. These results make the proposed detection system a very attractive tool for both laboratory research and advanced quality controls in mammography.

  15. Use of an Objective Structured Clinical Examination in Clinical Nurse Specialist Education.

    PubMed

    Cuevas, Heather E; Timmerman, Gayle M

    2016-01-01

    Helping patients maximize their potential using expert coaching to facilitate lifestyle change is an important practice area for clinical nurse specialists (CNSs). The purpose is to determine the usefulness of objective structured clinical examinations (OSCEs) for evaluating CNS students' coaching competencies in the context of facilitating lifestyle change. Despite the use of OSCEs to assess competencies in clinical skills (eg, performance of procedures, decision making), its potential for evaluating coaching competencies for lifestyle change has not been demonstrated. We developed 4 OSCEs dealing with coaching patients in exercise, weight loss, stress reduction, or nonpharmacologic management of hyperlipidemia. Evaluation criteria included (1) approach to the patient, (2) information gathering, (3) motivational interviewing, and (4) management (medical and behavioral strategies). Student performance ranged from highly organized with proficient coaching skills to disorganized and focused solely on clinical management and prescriptive communication. Student responses were positive. Objective structured clinical examinations were highly useful for evaluating CNS students' coaching competencies for lifestyle change. Using OSCEs early in the semester to provide students feedback on their performance and again at the end to determine improvement optimizes use of this teaching strategy.

  16. A randomized trial of three videos that differ in the framing of information about mammography in women 40 to 49 years old.

    PubMed

    Lewis, Carmen L; Pignone, Michael P; Sheridan, Stacey L; Downs, Stephen M; Kinsinger, Linda S

    2003-11-01

    To assess the effect of providing structured information about the benefits and harms of mammography in differing frames on women's perceptions of screening. Randomized control trial. General internal medicine academic practice. One hundred seventy-nine women aged 35 through 49. Women received 1 of 3 5-minute videos about the benefits and harms of screening mammography in women aged 40 to 49. These videos differed only in the way the probabilities of potential outcomes were framed (positive, neutral, or negative). We measured the change in accurate responses to questions about potential benefits and harms of mammography, and the change in the proportion of participants who perceived that the benefits of mammography were more important than the harms. Before seeing the videos, women's knowledge about the benefits and harms of mammography was inaccurate (82% responded incorrectly to all 3 knowledge questions). After seeing the videos, the proportion that answered correctly increased by 52%, 43%, and 30% for the 3 knowledge questions, respectively, but there were no differences between video frames. At baseline, most women thought the benefits of mammography outweighed the harms (79% positive frame, 80% neutral frame, and 85% negative frame). After the videos, these proportions were similar among the 3 groups (84%, 81%, 83%, P =.93). Women improved the accuracy of their responses to questions about the benefits and harms of mammography after seeing the videos, but this change was not affected by the framing of information. Women strongly perceived that the benefits of mammography outweighed the harms, and providing accurate information had no effect on these perceptions, regardless of how it was framed.

  17. Analyser-based mammography using single-image reconstruction.

    PubMed

    Briedis, Dahliyani; Siu, Karen K W; Paganin, David M; Pavlov, Konstantin M; Lewis, Rob A

    2005-08-07

    We implement an algorithm that is able to decode a single analyser-based x-ray phase-contrast image of a sample, converting it into an equivalent conventional absorption-contrast radiograph. The algorithm assumes the projection approximation for x-ray propagation in a single-material object embedded in a substrate of approximately uniform thickness. Unlike the phase-contrast images, which have both directional bias and a bias towards edges present in the sample, the reconstructed images are directly interpretable in terms of the projected absorption coefficient of the sample. The technique was applied to a Leeds TOR[MAM] phantom, which is designed to test mammogram quality by the inclusion of simulated microcalcifications, filaments and circular discs. This phantom was imaged at varying doses using three modalities: analyser-based synchrotron phase-contrast images converted to equivalent absorption radiographs using our algorithm, slot-scanned synchrotron imaging and imaging using a conventional mammography unit. Features in the resulting images were then assigned a quality score by volunteers. The single-image reconstruction method achieved higher scores at equivalent and lower doses than the conventional mammography images, but no improvement of visualization of the simulated microcalcifications, and some degradation in image quality at reduced doses for filament features.

  18. Randomized trial of a lay health advisor and computer intervention to increase mammography screening in African American women.

    PubMed

    Russell, Kathleen M; Champion, Victoria L; Monahan, Patrick O; Millon-Underwood, Sandra; Zhao, Qianqian; Spacey, Nicole; Rush, Nathan L; Paskett, Electra D

    2010-01-01

    Low-income African American women face numerous barriers to mammography screening. We tested the efficacy of a combined interactive computer program and lay health advisor intervention to increase mammography screening. In this randomized, single blind study, participants were 181 African American female health center patients of ages 41 to 75 years, at < or =250% of poverty level, with no breast cancer history, and with no screening mammogram in the past 15 months. They were assigned to either (a) a low-dose comparison group consisting of a culturally appropriate mammography screening pamphlet or (b) interactive, tailored computer instruction at baseline and four monthly lay health advisor counseling sessions. Self-reported screening data were collected at baseline and 6 months and verified by medical record. For intent-to-treat analysis of primary outcome (medical record-verified mammography screening, available on all but two participants), the intervention group had increased screening to 51% (45 of 89) compared with 18% (16 of 90) for the comparison group at 6 months. When adjusted for employment status, disability, first-degree relatives with breast cancer, health insurance, and previous breast biopsies, the intervention group was three times more likely (adjusted relative risk, 2.7; 95% confidence interval, 1.8-3.7; P < 0.0001) to get screened than the low-dose comparison group. Similar results were found for self-reported mammography stage of screening adoption. The combined intervention was efficacious in improving mammography screening in low-income African American women, with an unadjusted effect size (relative risk, 2.84) significantly higher (P < 0.05) than that in previous studies of each intervention alone.

  19. Post-Processing of Low Dose Mammography Images

    DTIC Science & Technology

    2002-05-01

    method of restoring images in the presence of blur as well as noise ” (12:276). The deblurring and denoising characteristics make Wiener filtering...independent noise . The signal dependant scatter noise can be modeled as blur in the mammography image. A Wiener filter with deblurring characteristics can...centered on. This method is used to eradicate noise impulses with high 26 pixel values (2:7). For the research at hand, the median filter would

  20. Satellite teleradiology test bed for digital mammography

    NASA Astrophysics Data System (ADS)

    Barnett, Bruce G.; Dudding, Kathryn E.; Abdel-Malek, Aiman A.; Mitchell, Robert J.

    1996-05-01

    Teleradiology offers significant improvement in efficiency and patient compliance over current practices in traditional film/screen-based diagnosis. The increasing number of women who need to be screened for breast cancer, including those in remote rural regions, make the advantages of teleradiology especially attractive for digital mammography. At the same time, the size and resolution of digital mammograms are among the most challenging to support in a cost effective teleradiology system. This paper will describe a teleradiology architecture developed for use with digital mammography by GE Corporate Research and Development in collaboration with Massachusetts General Hospital under National Cancer Institute (NCI/NIH) grant number R01 CA60246-01. The testbed architecture is based on the Digital Imaging and Communications in Medicine (DICOM) standard, created by the American College of Radiology and National Electrical Manufacturers Association. The testbed uses several Sun workstations running SunOS, which emulate a rural examination facility connected to a central diagnostic facility, and uses a TCP-based DICOM application to transfer images over a satellite link. Network performance depends on the product of the bandwidth times the round- trip time. A satellite link has a round trip of 513 milliseconds, making the bandwidth-delay a significant problem. This type of high bandwidth, high delay network is called a Long Fat Network, or LFN. The goal of this project was to quantify the performance of the satellite link, and evaluate the effectiveness of TCP over an LFN. Four workstations have Sun's HSI/S (High Speed Interface) option. Two are connected by a cable, and two are connected through a satellite link. Both interfaces have the same T1 bandwidth (1.544 Megabits per second). The only difference was the round trip time. Even with large window buffers, the time to transfer a file over the satellite link was significantly longer, due to the bandwidth-delay. To